Loading...
HomeMy WebLinkAboutPUD 2018-0006; BREAKERS VIEW BEACH HOMES; Planned Unit Development - Residential (PUD)Ccuyof Carlsbad LAND USE REVIEW APPLICATION P-1 ATTACHMENT 1 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov APPLICATIONS APPLIED FOR: (CHECK BOXES) Development Permits (FOR DEPT. USE ONLY) Legislative Permits ~ Coastal Development Permit 0 Conditional Use Permit D Minor O Extension 0 Day Care (Large) 0 Minor 0 Environmental Impact Assessment 0 Habitat Management Permit 0 Hillside Development Permit 0 Minor 0 Minor 0 Nonconforming Construction Permit --------t ~ Planned Development Permit D Minor , fot''U>I 9,. ~ Residential O Non-Residential t>OC i--....;;....c...;. ....... __ ..... Planning Commission Determination Reasonable Accommodation Site Development Plan Special Use Permit Tentative Parcel Map (Minor Subdivision) 0 General Plan Amendment D Local Coastal Program Amendment D Master Plan O Amendment D Specific Plan 0 Zone Change □Amendment D Zone Code Amendment South Carlsbad Coastal Review Area Permits D Review Permit 0 Administrative O Minor O Major Village Review Area Permits 0 Review Permit 0 Administrative O Minor D Major (FOR DEPT. USE ONLY) Tentative Tract Map (Major Subdivision) Variance ~Minor(Z) t:=-.a~-=-:::-.,.21,--f➔'2,'fl'. ~A \lU 1;eQJf y'l(U> 'Sf;fl'~ ~~-~~~ ~ "'11Dnf ~bl.I~ zo't.Alltmf-,o\"{ 'IA NOTE: A PROPOSED PROJECT REQUIRING APPLICATION SUBMITTAL MUST BE SUBMITTED BY APPOINTMENT". PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602-2723 TO SCHEDULE AN APPOINTMENT. ASSESSOR PARCEL NO(S): LOCATION OF PROJECT: NAME OF PROJECT: BRIEF DESCRIPTION OF PROJECT: PROJECT VALUE (SITE IMPROVEMENTS) FOR CITY USE ONLY *SAME DAY APPOINTMENTS ARE NOT AVAILABLE 204-232-12 3648 Carlsbad 81yd Breakers' View Beach Homes 2-Unit Condominium I Two-Family Residential Building +/-$2,700,000 estimated ESTIMATED COMPLETION DATE January 2020 Development No. 'W:\JW\P,r QO"\.~ Lead Case No. P-1 Page 1 of6 Revised 03/17 "-...... ATTACHMENT 1 OWNER NAME (PLEASE PRINT) APPLICANT NAME (PLEASE PRINT) INDIVIDUAL NAME INDIVIDUAL NAME (if applicable): Jason Ianni (if applicable): Jason Ianni COMPANY NAME 3648 Carlsbad Blvd. LLC COMPANY NAME 3648 Carlsbad Blvd. LLC (if applicable): (if applicable): MAILING ADDRESS: 2337 Catalina Ave. MAILING ADDRESS: 2337 Catalina Ave. CITY, STATE, ZIP: Vista, CA 92084 CITY, STATE, ZIP: Vista, CA 92084 TELEPHONE: (760) 521-1228 TELEPHONE: (760) 521-1228 EMAIL ADDRESS: Jasoni@mbarconline.com EMAIL ADDRESS: Jasoni@mbarconline.com I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE I CERTIFY THAT I AM THE LEGAL REPRESENTATIVE OF THE OWNER INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO KNOWLEDGE. I CERTIFY AS LEGAL OWNER THAT THE APPLICANT AS THE BEST OF MY KNOWLEDGE. SET FORTH HEREIN IS MY THORIZED REPRESENTATIVE FOR -~ PURPOSES OF THIS APP ON. j ~l--/f= 0-:;1-10 ~----·., SIGN~ DATE C--~URE -DATE APPLICANT'S REPRESENTATIVE Rachel Hege Sorrow, Architect (Print): MAILING ADDRESS: 888 O'Farrell Street, Suite W606 CITY, STATE, ZIP: San Francisco, CA 94109 TELEPHONE: 415.844.0783 EMAIL ADDRESS: rachelhege@comcast.net I CERTIFY THAT I AM THE REPRESENTATIVE OF THE APPLICANT FOR PURPOSES OF THIS APPLICATION AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE IN THE PROCESS OF REVIEWING THIS APPLICATION IT MAY BE NECESSARY FOR MEMBERS OF CITY STAFF, PLANNING COMMISSIONERS OR CITY COUNCIL MEMBERS TO INSPECT AND ENTER THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION. I/WE CONSENT TO ENTRY FOR THIS PURPOSE. NOTICE OF RESTRICTION: PROPERTY OWNER ACKNOWLEDGES AND CONSENTS TO A NOTICE OF RESTRICTION BEING RECORDED ON THE TITLE TO HIS PROPERTY IF CONDITIONED FOR THE APPLICANT. NOTICE OF RESTRICTIONS RUN WITH THE LAND AND BIND ANY SU SORS IN INTEREST. FOR CITY USE ONLY P-1 Page 2 of 6 MAY 21 2018 CITY OF CARLSRAD PU\~J~~ir,Jc_:; DIVISION DATE STAMP APPLICATION RECEIVED RECEIVED BY: Revised 03/17 Ccicyof Carlsbad DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. APPLICANT (Not the applicant's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Michael Jason Ianni Corp/Part ___________ _ Title Owner/ Trustee Title --------------Address 2337 Catalina Ave. Vista, CA 92084 Address ------------- 2. OWNER (Not the owner's agent) P-1 (A) Provide the COMPLETE, LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person Michael Jason Ianni & Shauna Ianni Title Owners I Trustees Address 2337 Catalina Ave Vista, CA 92084 Corp/Part. ___________ _ Title --------------- Address ------------- Page 1 of 2 Revised 07 /1 0 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non- profit organization or as trustee or beneficiary of the. Non Profit/Trust The Ianni Living Trust 9/15/11 Non Profit/Trust Title Michael Jason Ianni Trustee Address 2337 Catalina Ave. Vista, CA 92084 ----------- Title ______________ _ Address ____________ _ 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? D Yes l ✓I No If yes, please indicate person(s): ___________ _ NOTE: Attach additional sheets if necessary. I certify that all the above information is true and correct to the best of my knowledge. Ml'chael Jason Ianni· Digitally signed by Michael Jason Ianni Date: 2019.07.1018:57:10-07'00' Signature of owner/date Michael Jason Ianni Print or type name of owner Michael Jason Ianni Digitally signed by Michael Jason Ianni Date: 2019.07.1 O 18:57:26 -07'00' Signature of applicanUdate Michael Jason Ianni Print or type name of applicant Signature of owner/applicant's agent if applicable/date Michael Jason Ianni Print or type name of owner/applicant's agent P-1(A) Page 2 of 2 Revised 07/10 Certification of Trust for the Ianni Living Trust dated September 15, 2011 The Ianni Living Trust (the •·Trust'") was established on September 15. 201 l. The Settlors of the Trust are Michael Jason Ianni, also known as Jason Ianni, and Shauna L. Ianni. The Trustees are Michael Jason Ianni and Shauna L. Ianni (referred to collectively as the "Trustee"). The signature of any trustee is sufficient to exercise the powers of the Trustee. This Trust is revocable and amendable by Michael Jason Ianni and Shauna L. Ianni, acting jointly. The address of Michael Jason Ianni. Tnistee. is 262 Amelia Court. Vista, California 92084. The address of Shauna L. Ianni. Trustee. is 262 Amelia Court. Vista. California 92084. The tax identification number of the Trust is the Social Security number of either Settlor. Title to assets in the Trust shall be taken as follows: Michael Jason Ianni and Shauna L. Ianni. Trustees of the Ianni Living Trust dated September 15. 2011. and any amendments thereto. In addition, for titling purposes. any description referring to the Trust shall be effective if it includes the name of the Trust. the name of at least one initial or successor Trustee, and any reference indicating that property is being held by our Trustee in a fiduciary capacity. The Trustees under the trust agreement are authorized to acquire. sell, convey. encumber, lease. borrow. manage and otherwise deal with interests in real and personal property in trust name. The Ianni Living Trust has not been revoked. modified or amended in any way that would cause the representations in this Certification of Trust to be incorrect. Certification of Trust for the Ianni Living Trust Page 1 C By signing below, we each affinn and declare under penalty of perjury under the laws of the State of California that the foregoing declarations are true and correct. RELIANCE ON THIS CERTIFICATION This certification is made in accordance with California Probate Code Section 18100.5 and California Commercial Code Section 8402(a)(2)-(5) and is signed by all the currently acting Trustees. Any transaction entered into by a person acting in reliance on this certification shall be enforceable against the trust assets. PROBATE CODE SECTION 18100.S(h) PROVIDES THAT ANY PERSON WHO REFUSES TO ACCEPT THIS CERTIFICATION IN LIEU OF THE ORIGINAL TRUST DOCUMENT WILL BE LIABLE FOR DAMAGES, INCLUDING ATTORNEYS' FEES, INCURRED AS A RESULT OF THAT REFUSAL, IF THE COURT DETERMINES THAT THE PERSON ACTED IN BAD FAITH IN REQUESTING THE TRUST DOCUMENT. September 15,2011 ' .~ ~, ~ :i '<'llo ~ Shaunal. Ianni. Trustee Certification of Trust for the Ianni Living Trust Page 2 State of California ) County of=S=an"'-=D.::.;ie __ g=o ________ ) On September 15. 2011 before me, Holly J. Lacroix. a Notary Public (here insert name and title of the officer), personally appeared Michael Jason Ianni and Shaw1a L. Ianni, who proved to me on the basis of satisfactory evidence to be the person(s) whose nan1e(s) -Ware subscribed to the within instrument and acknowledged to me that helsne/they executed the same in -hislhcr/their authorized capacity(ies). and that by his/her/their signature(s) on the instrument the person(s). or the entity upon behalf of which the person(s) acted. executed the instrument. I certify under PENAL TY of PERJURY under the Jaws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. (Seal) Certification of Trust for th\! Ianni Living Tmst Page 3 Ccityof Carlsbad PROJECT DESCRIPTION P-1(8) PROJECT NAME: Breakers' View Beach Homes APPLICANT NAME: Jason Ianni ATTACHMENT 2 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 Please describe fully the proposed project by application type. Include any details necessary to adequately explain the scope and/or operation of the proposed project. You may also include any background information and supporting statements regarding the reasons for, or appropriateness of, the application. Use an addendum sheet if necessary. Description/Explanation: The applicant proposes to demolish one existing two-family home and to develop a two-family, residential air-space condominium project on .16 acre infill site within the Local Coastal Program and the Beach Area Overlay Zone (BAOZ). The site is located at 3648 Carlsbad Blvd. between Juniper and Cherry Avenues. The development of the proposed condominium project requires the processing and approval of a Planned Development Permit, Site Development Plan, Coastal Development Permit, Tentative Parcel Map and two Minor Variances. The Tentative Parcel Map associated with the subdivision is considered minor because it involves the division of land into four or fewer condominiums. Topographically, the site is generally flat with an elevation approximately 49 feet above mean sea level (MSL). The site is developed with one two-family home and does not contain any sensitive vegetation. The proposed project contains one, two-story on grade two-family building. The first floor contains two enclosed 2-car garages, two bedrooms and a great room. Access to the parking garages is from a 20 ft. public alley off Juniper Avenue. One guest parking space is located in front of each garage. Both units are a combination of a single level great-room attached to a two-level townhouse wing containing bedrooms, bathrooms, individual stairs and private elevators, and garages. Both homes have similar floor plans consisting of three bedrooms, and unit-one has approximately 3,400 square feet and unit-2 has approximately 3,600 square feet. The front entries face Carlsbad Blvd. and each unit includes patios or balconies and individual private roof deck areas. The underlying lot will be held in common interest divided between the two airspace condominiums. The common area includes, but is not limited to, the driveway and guest parking area and landscaping. The project is an updated Arts and Crafts Prairie House style architecture. Primary building materials include, exposed architectural grade concrete, Palos Verdes stone and tile veneer, tan stucco, metal clad fascia, and recessed metal clad windows and sliding doors. A standing seam metal roof with a 3: 12 roof pitch covers a portion of the building. A combination of pony-wall and wrought-iron railings are used at the balconies and a decorative wrought iron railing surround the roof deck areas. The project has a height limit of 30 feet and the majority of the two-family airspace condominium project has an overall building height of approximately 30 ft. tall as measured from the existing or finished grade, whichever is lower. A stairway and elevator tower located in the middle of the building, extends to approximately 35 feet in height. Roof structures specifically for the housing of elevators and stairways may be erected above the height limits, provided the enclosed area does not provide additional floor area or be taller than the minimum height required to accommodate or enclose the intended use. The flat roof areas and roof decks are approximately 21 feet in height. P-1(8) Page 1 of 1 Revised 07/10 I' . Certification of Trust for the Ianni Living Trust dated September 15, 2011 ATTACHMENT 11 The Ianni Living Trust (the '•TrusC) was established on September 15, 2011. The Settlors of the Trust are Michael Jason Ianni. also known as Jason Ianni, and Shauna L. Ianni. The Trustees are Michael Jason Ianni and Shauna L. Ianni (referred to collectively as the "Trustee"). The signature of any tmstee is sufficient to exercise the powers of the Trustee. This Trust is revocable and amendable by Michael Jason Ianni and Shauna L. Ianni, acting jointly. The address of Michael Jason Ianni. Trnstee. is 162 Amelia Court. Vista. California 92084. The address of Shauna L. Ianni. Trustee. is 262 Amelia Court. Vista. California 92084. The tax identification number of the Trust is the Social Security number of either Settlor. Title to assets in the Trust shall be taken as follows: Michael Jason Ianni and Shauna L. Ianni. Trustees of the Ianni Living Trust dated September 15.1011. and any amendments thereto. In addition. for titling purposes. any description referring to the Trust shall be effective if it includes the name of the Trust. the name of at least one initial or successor Trustee, and any reference indicating that property is being held by our Trustee in a fiduciary capacity. The Trustees under the trust agreement are authorized to acquire. sell. convey. encumber. lease. borrow. manage and otherwise deal with interests in real and personal property in trust name. The Ianni Living Trust has not been revoked. modified or amended in any way that would cause the representations in this Certification of Trust to be incorrect. Certification of Trust fur the Ianni Living Trust Page I 0 ATTACHMENT 11 By signing below. we each affirm and declare under penalty of perjury under the laws of the State of California that the foregoing declarations are true and correct. RELIANCE ON THIS CERTIFICATION This certification is made in accordance with California Probate Code Section 18100.5 and California Commercial Code Section 8402(a){2)-(5) and is signed by all the currently acting Trustees. Any transaction entered into by a person acting in reliance on this certification shall be enforceable against the trust assets. PROBATE CODE SECTION 18100.S(h) PROVIDES THAT ANY PERSON WHO REFUSES TO ACCEPT THIS CERTIFICATION IN LIEU OF THE ORIGINAL TRUST DOCUMENT WILL BE LIABLE FOR DAMAGES, INCLUDING ATTORNEYS' FEES, INCURRED AS A RESULT OF THAT REFUSAL, IF THE COURT DETERMINES THAT THE PERSON ACTED IN BAD FAITH IN REQUESTING THE TRUST DOCUMENT. September 15, 20 I 1 ' -~ Cu+,.... :i do~ ~L Ianni. Trustee Certification of Trust for the Ianni Living Trust Page 2 .....,, ATTACHMENT 11 State of California County of_S_an_D_ie_.,g...,_,o ________ ) On September 15. 2011 before me. Holly J. LaCroix. a Notary Public (here insert name and title of the officer), personally appeared Michael Jason Ianni and Shauna L. Ianni. who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) -islare subscribed to the within instrument and acknowledged to me that ~they executed the same in ---msfhcr/their authorized capacity(ies). and that by htsther/their signature(s) on the instrument the person(s). or the entity upon behalf of which the person(s) acted. executed the instrument. I certify under PENAL TY of PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. (Seal) Certification of Trust for the Ianni Living Tmst Page 3 MAY 18, 2018 TRANSPACIFIC ARCHITECTS 888 O'FARRELL STREET, TRINITY TOWERS SUITE W606, SAN FRANCISCO, CA 94109 415.844.0783 PLANNING DEPARTMENT COMMUNITY & ECONOMIC DEVELOPMENT, CITY OF CARLSBAD 1635 FARADAY AVENUE, CA 92008-7314 TRANSMITTAL: Application for Land Use Review for Proposed Two-Family Condominium Building located at 3648 Carlsbad Blvd., known as, Breakers' View Beach Homes Carlsbad. Please find attached the following documents. Copies: 1 2 2 l 2 7 7 2 2 7 Attachments: ( l) P-1 Land Use Review Application (2) P-1 (B) Project Description Explanation Sheet (3) P-1 (DJ Environmental Information Assessment (4) Preliminary Title Report & Platted Easements (dated 4/26/2018) (5) E-32 SWPPP & Tier Level (6) Noise Study Assessment (7) E-34 Storm Water Questionnaire (8) P-1 (CJ Hazard Waste & Substance Application (9) P-1 (E) Notice of Time Limits (l 0) P-1 (F) Waiver of Time Limits ( l l ) Certificate of Ownership ( 12) Policy 44 Design Guidelines Compliance (13) Policy 66 Livable Neighborhoods Compliance (14) Table C: Development Standards Compliance (15) Table E: Condominium Project Compliance ( 16) Proposal for Architectural Style Compliant with Policy 44 (17) Application for Two Minor Variances P-4 ( 18) Site Photographs ( 19) Architectural Plans (20) Tentative Parcel Map (21) Preliminary Drainage Study for Tentative Map (22) Soils Report & Update Letter (23) Conceptual Landscape Plan (24) E-36 Standard Project Requirement Checklist Thank you for your assistance in this matter. Please contact us if there are any questions or other needs. *Delivery under separate transmittal and carrier. Page 1 of 1 (cicyof Carlsbad DISCLOSURE STATEMENT P-1(A) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov Applicant's statement or disclosure of certain ownership interests on all applications which will require discretionary action on the part of the City Council or any appointed Board, Commission or Committee. The following information MUST be disclosed at the time of application submittal. Your project cannot be reviewed until this information is completed. Please print. Note: Person is defined as "Any individual, firm, co-partnership, joint venture, association, social club, fraternal organization, corporation, estate, trust, receiver, syndicate, in this and any other county, city and county, city municipality, district or other political subdivision or any other group or combination acting as a unit." Agents may sign this document; however, the legal name and entity of the applicant and property owner must be provided below. 1. 2. P-1{A) APPLICANT (Not the applicant's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having a financial interest in the application. If the applicant includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person , 1/iS'u r1_/4t1r11 Corp/Part. __________ _ Title {2vl7 d Title ___________ _ Address :AJ, J7 C1tflf l,r a/4 1/(f? J Address _________ _ J/YJ7.I c 11 9Jo8'1 OWNER (Not the owner's agent) Provide the COMPLETE, LEGAL names and addresses of ALL persons having any ownership interest in the property involved. Also, provide the nature of the legal ownership (i.e., partnership, tenants in common, non-profit, corporation, etc.). If the ownership includes a corporation or partnership, include the names, titles, addresses of all individuals owning more than 10% of the shares. IF NO INDIVIDUALS OWN MORE THAN 10% OF THE SHARES, PLEASE INDICATE NON-APPLICABLE (N/A) IN THE SPACE BELOW. If a publicly-owned corporation, include the names, titles, and addresses of the corporate officers. (A separate page may be attached if necessary.) Person iflo()Y"'J fll'J/7, V Corp/Part~--------- Title Ov-/'JtJ/ Title _____________ _ Address J.JJ7 c11l11/{t,1 /f;,,-t. Address. _________ _ 1/J ?J r/f C,1 /J-d t/11 Page 1 of 2 Revised 07/10 3. NON-PROFIT ORGANIZATION OR TRUST If any person identified pursuant to (1) or (2) above is a nonprofit organization or a trust, list the names and addresses of ANY person serving as an officer or director of the non- profit-organization or as trustee or beneficiary of the. Non Profit/Trust________ Non Profit/Trust _________ _ Title Title -------------------------- Address Address ---------------------- 4. Have you had more than $500 worth of business transacted with any member of City staff, Boards, Commissions, Committees and/or Council within the past twelve (12) months? D Yes ~No If yes, please indicate person(s): __________ _ NOTE: Attach additional sheets if necessary. I certify that all the above · formation is true and correct to the best of my knowledge. / Print or type name of owner ortype name of applicant Signature of owner/applicant's agent if applicable/date Print or type name of owner/applicant's agent P-1(A) Page 2 of 2 Revised 07 /10 {._cityof Carlsbad HAZARDOUS WASTE AND SUBSTANCES STATEMENT P-1(C) ATTACHMENT 8 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www .carlsbadca.gov Consultation of Lists of Sites Related to Hazardous Wastes (Certification of Compliance with Government Code Section 65962.5) Pursuant to State of California Government Code Section 65962.5, I have consulted the Hazardous Waste and Substances Sites List compiled by the California Environmental Protection Agency and hereby certify that (check one): [RI The development project and any alternatives proposed in this application are not contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. D The development project and any alternatives proposed in this application a.re.contained on the lists compiled pursuant to Section 65962.5 of the State Government Code. APPLICANT PROPERTY OWNER Name: Jason Ianni Name: Jason Ianni Address: 2337 Catalina Ave. Address: 2337 Catalina Ave. Vista, CA 92084 Vista, CA 92084 Phone Number: 760.521.1228 Phone Number: 760.521.1228 Address of Site: 3648 Carlsbad Blvd. Local Agency (City and County): City of Carlsbad, San Diego County Assessor's book, page, and parcel number: 204-232-12, Lot P in Block 2 of Palisades Heights, Map No. 1777 City of Carlsbad, County of San Diego, Recorded Jan. 11, 1924 Specify list(s): ______________________________ _ Regulatory Identification Number: ________________________ _ The Hazardous Waste and Substances Sites List (Cortese List) is used by the State, local agencies and developers to comply with the California Environmental Quality Act requirements in providing information about the location of hazardous materials release sites. P-1(C) Page 1 of 2 Revised 02/13 C 0 ATTACHMENT 8 Per the California Environmental Protection Agency's website, 'While Government Code Section 65962.5 [referred to as the Cortese List] makes reference to the preparation of a "list," many changes have occurred related to web-based information access since [the amended statute's effective date in] 1992 and this information is now largely available on the Internet sites of the responsible organizations. Those requesting a copy of the Cortese "list" are now referred directly to the appropriate information resources contained on the Internet web sites of the boards or departments that are referenced in the statute." Below is a list of agencies that maintain information regarding hazardous waste and substances sites. Department of Toxic Substances Control www.calepa.ca.gov/sitecleanup/CorteseList/default.htm www. calepa. ca. gov/database/calsites www.envirostor.dtsc.ca.gov/public EnviroStor Help Desk (916) 323-3400 State Water Resources Control Board http:/lgeotracker. waterboards.ca.gov/ County of San Diego Department of Environmental Health Services www.co.san-diego.ca.us/deh Hazardous Materials Division www.sdcounty.ca.gov/deh/hazmat/hazmat permits.html Mailing Address: County of San Diego Department of Environmental Health P.O. Box 129261 San Diego, CA 92112-9261 Call Duty Specialist for technical questions at (858) 505-6880, fax (858) 505-6868 (fax) Environmental Protection Agency National Priorities Sites ("Superfund" or "CERCLIS") www.epa.gov/superfund/siteslcursites (800) 424-9346 or (702) 284-8214 National Priorities List Sites in the United States www.epa.gov/superfund/siteslnpl/npl.htm P-1(C) Page 2 of 2 Revised 02/13 ATTACHMENT 3 ENVIRONMENTAL INFORMATION FORM (To be Completed by Applicant) Date Filed: _5_/_fJ-_l ..... /_r6 _______ (To be completed by City) Application Number(s): ________________________ _ General Information 1. Name of project: _B_r_e_a_k_e_rs_1_V_ie_w _________________ _ N f d I . t 3648 Carlsbad Blvd LLC -Jason Ianni, Managing Partner 2. ame o eve oper or proJec sponsor: _________________ _ 3. Address: 2337 Catalina Avenue City, State, Zip Code: Vista, CA 92084 Phone Number: 760-521-1228 Name of person to be contacted concerning this project: Address: 5115 Avenida Encinas, Suite L City, State, Zip Code: Carlsbad, CA 92008 Phone Number: 760-931-8700 Rod Bradley -BHA, Inc. 4. Address of Project: 3648 Carlsbad Blvd. Assessor's Parcel Number: 204-232-12 --------------------- 5. List and describe any other related permits and other public approvals required for this project, including those required by city, regional, state and federal agencies: coastal development permit, planned unit development, site development permit 6. Existing General Plan Land Use Designation: R-23 Residential (15-23 DUs) 7. Existing zoning district: R-3 multiple family residential zone 8. Existing land use(s): single family residential 9. Proposed use of site (Project for which this form is filed): ___________ _ development of two (2) condominium units with parking Project Description 10. Site size: 0.16 AC -6,892 SF 11. 12: 13. 14. P-1(D) Proposed Building square footage: _8_,_6_4_5_S_F ______________ _ Number of floors of construction: _2 __________________ _ Amount of off-street parking provided: _N_/_A ________________ _ Associated projects: _N_/_A _____________________ _ Page 2 of 4 Revised 07/10 0 15. If residential, include the number of units and schedule of unit sizes: 2 units Unit1: 4,196SF Unit 2: 4,449 SF 16. If commercial, indicate the type, whether neighborhood, city or regionally oriented, square footage of sales area, and loading facilities: N/A 17. If industrial, indicate type, estimated employment per shift, and loading facilities: _____ _ N/A 18. If institutional, indicate the major function, estimated employment per shift, estimated occupancy, loading facilities, and community benefits to be derived from the project: N/A 19. If the project involves a variance, conditional use or rezoning applications, state this and indicate clearly why the application is required: N/A P-1(D) Page 3 of 4 Revised 07/10 Are the following items applicable to the project or its effects? Discuss all items checked yes (attach additional sheets as necessary). Yes No 20. Change in existing features of any bays, tidelands, beaches, or hills, or substantial □ IZI alteration of ground contours. 21. Change in scenic views or vistas from existing residential areas or public lands or □ IZI roads. 22. Change in pattern, scale or character of general area of project. □ IZI 23. Significant amounts of solid waste or litter. □ IZI 24. Change in dust, ash, smoke, fumes or odors in vicinity. □ IZI 25. Change in ocean, bay, lake, stream or ground water quality or quantity, or □ IZI alteration of existing drainage patterns. 26. Substantial change in existing noise or vibration levels in the vicinity. □ [ZI 27. Site on filled land or on slope of 1 0 percent or more. □ IZI 28. Use of disposal of potentially hazardous materials, such as toxic substances, □ IZI flammables or explosives. 29. Substantial change in demand for municipal services (police, fire, water, sewage, □ IZI etc.). 30. Substantially increase fossil fuel consumption (electricity, oil, natural gas, etc.). □ [ZI 31. Relationship to a larger project or series of projects. □ IZI Environmental Setting Attach sheets that include a response to the following questions: 32. Describe the project site as it exists before the project, including information on topography, soil stability, plants and animals, and any cultural, historical or scenic aspects. Describe any existing structures on the site, and the use of the structures. Attach photographs of the site. Snapshots or Polaroid photos will be accepted. 33. Describe the surrounding properties, including information on plants and animals and any cultural, historical or scenic aspects. Indicate the type of land use (residential, commercial, etc.), intensity of land use (one-family, apartment houses, shops, department stores, etc.), and scale of development (height, frontage, set-back, rear yard, etc.). Attach photographs of the vicinity. Snapshots or polaroid photos will be accepted. Certification I hereby certify that the statements furnished above and in the attached exhibits present the data and information required for this initial evaluation to the best of my ability, and that the facts, statements, and information presented are true and correct to the best of my knowledge and belief. Date: __ &....,/ ___ r;-_._t __ l_~ ___ _ P-1(D) Page4 of 4 Revised 07/10 C 0 ENVIRONMENTAL SETTING INFORMATION CONTINUED: 32. The subject property is relatively flat and is developed with a single family residence and attached garage. The site is surrounded by multi-family dwellings fronts Carlsbad Blvd. but will gain access off of Juniper Avenue via a 20-foot wide Private Road Easement. The site is one hundred percent (100%) disturbed by the existing development. A geotechnical investigation has been performed and a report prepared, dated February 11, 2016. The Geotechnical Report was prepared by Coast Geotechnical. The subject property is located in an area that is relatively free of geologic hazards. 33. The subject property is surrounded by multi-family development (north, east and south) while Carlsbad Blvd. is to the west. The proposed project is comprised of a 2-unit, 2- story condominium. The existing and proposed development enjoy views of the Pacific Ocean to the west. environmental-info.mis 1 OF3 1 -NORTHERLY VIEW OF PROPERTY FROM CARLSBAD BLVD. 2 -NORTH WEST VIEW OF CARLSBAD BL VD. FROM FRONT OF PROPERTY 20F3 3 -SOUTHERLY VIEW OF CARLSBAD BLVD. FROM FRONT OF PROPERTY 4 -NORTHERLY VIEW OF REAR DRIVEWAY FROM JUNIPER A VE. ' . . 3 OF3 5 -NORTHERLY VIEW OF ALLEY LOCATED BEHIND PROPERTY FROM JUNIPER A VE. 6 -SOUTHERLY VIEW OF ALLEY FROM REAR DRIVEWAY C City of Carlsbad TIME LIMITS ON DISCRETIONARY PROJECTS P-1(E) PLEASE NOTE: ATTACHMENT 9 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www .carlsbadca.gov Time limits on the processing of discretionary projects established by state law do not start until a project application is deemed complete by the City. The City has 30 calendar days from the date of application submittal to determine whether an application is complete or incomplete. Within 30 days of submittal of this application you will receive a letter stating whether this application is complete or incomplete. If it is incomplete, the letter will state what is needed to make this application complete. When the application is complete, the processing period will start upon the date of the completion letter. If you have any questions regarding application submittal requirements (i.e., clarification regarding a specific requirement or whether all requirements are necessary for your particular application) please call (760) 602-4610. Applicant Signature: Staff Signature: Date: To be stapled with receipt to the application C City of Carlsbad TENTATIVE PARCEL MAP WAIVER OF PROCESSING TIME LIMITS P-1(F) ATTACHMENT 10 Development Services Planning Division 1635 Faraday Avenue 760-602-4610 www.carlsbadca.gov Proposed Minor Subdivision No.: ____________ located at 3648 Carlsbad Blvd. Subdivision Map Act (SMA) Section 66452.1 sets a 50-day time limit for the Planning Division to process tentative parcel maps. Per SMA Section 66451.1, this time limit may be extended by mutual consent of the applicant and the city to allow for concurrent processing of related approvals or an environmental review of the project. By accepting applications for tentative parcel maps concurrently with applications for other approvals that are prerequisites to the map (e.g., Environmental Information Form, Environmental Impact Report, Condominium Permit, Planned Unit Development), the 50-day time limit is often exceeded. For the city to process a tentative parcel map application concurrently, the property owner or applicant must sign this agreement. If this agreement is not signed, the city will accept the tentative parcel map application only after all prerequisites to the map have been processed and approved. The undersigned acknowledges the processing time required by the city is expected to exceed the 50-day time restriction and hereby waives such time restriction for city planner action. Jason Ianni Signer is (check one): ________________________ []!Property Owner □Applicant Signature Print Name Date Jason Ianni Signer is (check one): ________________________ OPropertyOwner [Z]Applicant Signature Print Name Date (city of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST P-30 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov In September 2015, the City of Carlsbad adopted a Climate Action Plan (CAP) that outlines actions that the city will undertake to achieve its proportional share of state greenhouse gas (GHG) emissions reductions. This checklist contains measures that are required to be implemented on a project-by-project basis to ensure that the specified emissions targets identified in the Climate Action Plan (CAP) are achieved. Implementation of these measures will ensure that new development is consistent with the CAP's assumption for relevant CAP strategies toward achieving the identified greenhouse gas (GHG) reduction targets. In this manner, a project's incremental contribution to a cumulative GHG emissions effect may be determined not to be cumulatively considerable if it complies with the requirements of the CAP, in accordance with CEQA Guidelines Sections 15064(h)(3), 15130(d), and 15183(b). This checklist is intended to assist project applicants in identifying CAP ordinance requirements and demonstrate how their project fulfills those requirements. This checklist is to be completed and included in applications for new development projects that are subject to discretionary review or require a building permit. APPLICATION SUBMITTAL REQUIREMENTS ..i1111 The completed checklist must be included in the project submittal package or building permit application. Application submittal procedures can be found on the City of Carlsbad website. This checklist is designed to assist the applicant in identifying the minimum CAP-related requirements specific to their project. However, it may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances . ..i1111 If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Planning Division or building official. ..i1111 The requirements in the checklist will be included in the project's conditions of approval or issuance of building permit. ..i1111 Details on CAP ordinance requirements are available on the city's website. P-30 Page 1 of 7 RECF~IVED JUL 1 ~ 2019 CITY OF CARLSBAD PLANNING DIVISION Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist STEP 1: LAND USE CONSISTENCY The first step in determining CAP consistency for discretionary development is to assess the project's consistency with the growth projections used in the development of the CAP. This section allows the city to determine a project's consistency with the land use assumptions used in the CAP. Projects found not to be consistent with the CAP's land use assumptions and that are projected to emit at or above the CAP screening threshold of 900 metric tons of CO2 equivalent (MTCO2e) GHG will be subject to a project- specific analysis of GHG emissions' impact on the environment in accordance with the requirements of the California Environmental Quality Act (CEQA). This may result in GHG-reducing mitigation measures applied as a condition of project approval in addition to compliance with the CAP ordinance requirements identified in Step 2 of this checklist. Checklist Item (Check the appropriate box and provide an explanation and supporting documentation for your answer) A Is the proposed project consistent with the existing General Plan land use and specific/master plan or zoning designations? OR, If the proposed project is not consistent with the existing land use plan and zoning designations, does the project include a land use plan and/or specific plan, master plan or zoning designation amendment that would result in an equivalent or less GHG-intensive project when compared to the existing designations? Yes No □ If ''Yes", proceed to Step 2 of the checklist. For the second option under Question A above, provide estimated project-related GHG emissions under both existing and proposed designation(s) for comparison. GHG emissions must be estimated in accordance with the City of Car1sbad Guidance to Demonstrating Consistency with the Climate Action Plan. If "No", proceed to Question B. B. The CAP established a screening threshold of 900 MTCOielyear for new development projects to assist in determining consistency with the CAP. The types and sizes of typical projects listed below have been determined to correspond to the CAP screening threshold. Will the proposed land use change result in the construction of less than any one of the following? • Single-Family Housing: 50 dwelling units • Multi-Family Housing: 70 dwelling units • Office: 35,000 square feet • Retail Store: 11,000 square feet • Grocery Store: 6,300 square feet • Other: If the proposed project is not one of the above types, provide a project-specific GHG emissions analysis to determine whether it is below the 900 MTCOie/year screening threshold. If ''Yes", proceed to Step 2 of the checklist □ □ If "No", the project's GHG impact is potentially significant and must be analyzed in accordance with CEQA. Applicant must prepare a Self-developed GHG emissions reduction program in accordance with the City of Car1sbad Guidance to Demonstrating Consistency with the Climate Action Plan to demonstrate how it would offset the increase in emissions over the existing designations. The project must incorporate each of the applicable measures identified in Step 2 to mitigate cumulative GHG emissions impacts unless the decision maker finds that a measure is infeasible in accordance with California Environmental Quality Act Guidelines Section 15091 . Mitigation in lieu of or in addition to the measures in Step 2 may be required, depending on the results of the project-specific GHG impact analysis. Proceed and complete a project-specific Self-developed GHG emissions reduction program and Step 2 of the Checklist. P-30 Page 2 of 7 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist STEP 2: CAP ORDINANCE COMPLIANCE REQUIREMENTS Completion of this checklist will document a project's compliance with CAP ordinances, and in turn, demonstrate consistency with the applicable measures and actions of the CAP. The compliance requirements in this Step 2 apply to development projects that require a building permit. All other development projects shall implement all emissions-related mitigation measures from the General Plan Update EIR. Project No./Name: BREAKERS VIEW CONDOMINIUMS Property Address/APN: 3648 CARLSBAD BLVD. CARLSBAD, CA 92008 / 204-232-12-00 Applicant Name/Co.: JOHN P. JENSEN ARCHITECT Applicant Address: 130 S. CEDROS #220 SOLANA BEACH, CA. 92075 Contact Phone: 858.756.2526 Contact Email: llensen@johnjensenarchitect.com Contact information of person completing this checklist (if different than above): Name: JASON MOLGREN -PROJECT MANAGER Contact Phone: 281 .684.4871 Company name/address: JOHN P. JENSEN ARCHITECT Contact Email: jmolgren@johnjensenarchitect.com Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. If your project includes alterations or additions to an existing building, please contact the Carlsbad Building Division for assistance in estimating building permit valuation, by phone at 760-602-2719 or by email at building@carlsbadca.gov. Estimated Building Permit Valuation (BPV): $ _______ _ Construction Type I Complete Sectlon(s) I Notes: ~ Residential 8 New construction I 2A, 3A and 4A i 2-FAMIL Y DWELLING D Alterations: D BPV <!: $60,000 1A All residential alterations D BPV <!: $60,000 1A and 4A 1-2 family dwellings and townhouses with attached garages D Electrical service panel upgrade 4A only Multi-family dwellings only where interior finishes are removed D BPV <!: $200,000 1A and 4A and significant site work and upgrades to structural and mechanical , electrical, and/or plumbing systems are proposed D Nonresidential D New construction I 18, 28, 38, 48 and 5 D Alterations : P-30 Page 3 of 7 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist □ BPV 2!: $200,000 or additions 2!: 1,000 1B, 5 square feet □ BPV 2!: $1 ,000,000 1B, 2B and 5 Building alterations of 2!: 75% existing gross floor area □ 2!: 2,000 sq. ft. new roof addition 2B and 5 1 B also applies if BPV 2!: $200,000 Checklist Item Check the appropriate boxes, explain ml not applicable and exception items, and provide suppcrting cala.dations 111d doaJrnentation as necessary. 1. Energy Efficiency Please refer to Carlsbad Ordinance No. CS-347 and the California Green Building Standards Code (CALGreen) for more information when completing this section. A ~ Residential addition or alteration ~ $60,000 building pennit valuation. See Ord. CS-347, Section 8. Year Built Single-family Requirements □ Before 1978 Select one: 0 Duct sealina 0 Attic insulation □ Cool roof □ 1978 and later Select one: 0 Lighting package □ Water heating package □ Between 1978 and 1990 □ 1991 and later □ N/A. _________ _ □ Exception: Home energy score~ 7 (attach certification) Multi-family Requirements □ Attic insulation Select one: □ Attic insulation □ Duct Sealina □ Cool roof Select one: □ Lighting package □ Water heating package B. D Nonresidential* new construction or alterations~ $200,000 building pennit valuation, or additions~ 1,000 square feet □ N/A. _________ _ See CALGreen Appendix AS, Discussion AS.2, as amended in CS-347, Section 3. AS.203.1.1 .1 □ Outdoor lighting: .90 Allowed Outdoor Lighting Power □ N/A AS.203.1 .1 .2 □ Restaurant service water heating (comply with California Energy Code Section 140.5, as amended) □ N/A AS.203.1.2.1 Choose one as applicable: □ .95 Energy budget □ .90 Energy budget □ N/A AS.21 1.1.** 0 On-site renewable energy □ N/A AS.211 .3** □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A AS.212.1 0 Elevators and escalators □ N/A AS.213.1 □ Steel framing □ N/A P-30 Page 4 of 7 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist * Includes hotels/motels and high-rise residential buildings •• For alterations~ $1 ,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with California Energy Code section 120.10 instead. 2. Photovoltaic Systems A. ~ Residential new construction (for building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1 (c) 14 for requirements. Note: if project includes installation of an electric heat pump water heater pursuant to Car1sbad ordinance CS-348, increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) "A" 2,837 1 2.77 "B" 2,905 1 2.82 Total System Size: 5.6 kWdc = (CFAx.572) / 1,000 + (1.15 x#d.u.) *Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ kWdc B. D Nonresidential new construction or alterations i!:$1,000,000 BPV and affecting i!:75% existing floor area, or addition that increases roof area by =!:2,000 square feet Please refer to Car1sbad Ordinance CS-347, Section 6 when completing this section. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: □If< 10,000s.f. Enter: 5 kWdc Min. System Size: □ If~ 1 O,OOOs.f. calculate: 15 kWdc x (GFN10,000) ** kWdc --- **Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Annual TDV Energy use:*** _____ _ x .80= Min. system size: ____ _ kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. P-30 Page 5 of 7 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist 3. Water Heating A ~ Residential and hotel/motel new construction Please refer to Carlsbad Ordinance CS-347 and CS-348 when completing this section. 181 For systems serving individual dwelling units choose one: □ Heat pump water heater AND compact hot water distribution AND drain water heat recovery (low-rise residential only) 181 Heat pump water heater AND PV system .3 kWdc larger than required in CA Energy Code Section 120.10 (for high rise residential hotel/motel) or 150.1 (c) 14 (for low-rise residential) □ Heat pump water heater meeting Tier 3 or higher NEEA Advanced Water Heating Specification □ Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CS-347 (high-rise residential, hotel/motel) or CS-348 (low-rise residential) □ Solar water heating system that is either: □ .60 solar savings fraction or 40 s.f. solar collectors □ .40 solar savings fraction, plus drain water heat recovery □ Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CS-347 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □ Solar water heating system with .40 solar savings fraction □ Exception : 4. Electric Vehicle Charging A. ~ Residential New construction and major alterations* Please refer to Carlsbad Ordinance CS-349 when completing this section. 181 One and two-family residential dwelling or townhouse with attached garage: ~ One EVSE ready parking space required □ Exception : □ Multi-family residential· □Exception: Total Parking Spaces EVSESpaces Proposed Caoable I Ready I 2 I I Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed .") P-30 Page 6 of 7 Installed Total 2 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B. D Nonresidential new construction (includes hotels/motels) □ Exception · Total Parking Spaces EVSE Spaces Proposed Capable Ready Installed Total Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Soaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 percent of total 50 percent of Required EV Spaces 5. D Transportation Demand Management (TOM) A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use. B. Employee ADT/1 ,000 square feet is selected from the City of Carlsbad Employee ADT Table. Use GFA Employee ADT/1 ,000 S.F. Total Employee ADT Total If total employee ADT is greater than or equal to 110 employee ADT, a TDM plan is required. *NOTE: Notwithstanding the 110 employee ADT threshold above, General Plan Mobility Element Policy 3-P.11 requires new development that adds vehicle traffic to vehicle LOS-exempt street facilities to implement TDM and transportation system management strategies. Please consult with City of Carlsbad Land Development Engineering (LDE) staff to determine whether this policy applies to your project. TDM plan required: Yes D No D LDE Staff Verification: □-----(staff initials) P-30 Page 7 of 7 Revised 04/19 ATTACHMENT 17 TRANSPACIFIC ARCHITECTS May 1, 2018 Planning Department 888 0 'F AR RELL S TR EE T, T R I N IT Y T O W ERS SUI TE W60 6, S AN FR AN Cl SCO, CA 94 109 Community & Economic Development, City of Carlsbad 1635 Faraday Avenue, CA 92008-7314 SUBJECT: Applicant Proposal for Two Variances of Policy 44, for PUD, SDP,CDP,MS, BREAKERS VIEW CARLBAD Please find attached our application and supporting documentation for two minor variances of Council Policy 44. l . To allow the required open recreational space to be located within the front yard setbac k. 2. To allow the private enclosed 2-car garages to have a width of 19 feet in lieu of the standard 20 feet. Please find attached the P-4 Justification For Variance Applic ation Thank you very much for your c ontinued assistance with this project. Sincerely yours, R.aoheL eLLe Hege sorrow Rachel E. Hege Sorrow, AIA TransPacific Architects ATTACHMENT 17 1. Locating Open Recreational Space in Front Yard Setback JUSTIFICATION FOR VARIANCE By law a Variance may be approved only if certain facts are found to exist. Please read these requirements carefully and explain how the proposed project meets each of these facts. Use additional sheets if necessary. Explain what special circumstances are applicable to the subject property, including size, shape, topography, location or surroundings, whereby the strict application of the zoning ordinance deprives such property of privileges enjoyed by other property in the vicinity and under identical zoning classification: The lot is a substandard lot at 6,890 square feet, which falls below the 7,500 square foot minimum lot size. There is a 15 ft. private road easement, a standard utility easement, and a 15 ft. fire lane designation. Because any new vehicle access is denied from Carlsbad Blvd., access to the site is from a 20 ft. wide public alley off Juniper Ave. that terminates at the rear of the site. There, the 15 foot wide private road easement, standard utility easement, and 15 fl. fire lane designation extend across the entire width of the site. This precludes locating the open recreational space in the rear yard. The easements have also resulted in increasing the size of the rear yard from the required 12'-6" to the easement required 15 feet. Explain why the granting of the variance does not constitute a grant of special privileges inconsistent with the limitations upon other properties in the vicinity and zone in which the subject property is located and is subject to any conditions necessary to assure compliance with this finding: The granting of locating the open recreational space in the front-yard setback, directly facing Carlsbad Blvd, where no driveway or vehicle access is allowed, and has a substandard sidewalk and parkway of only 6 feet, and provides the open space with unobstructed ocean views, is not a special privilege based on the substandard lot size, lhe two easements and a fire lane designation. Explain why the granting of the variance does not authorize a use or activity which is not otherwise expressly authorized by the zone regulation governing the subject property: The granting of a variance to locate the required open recreational space in the front-yard setback area does not authorize a use which is not otherwise expressly permitted by the zoning regulations. Therefore, the locating of unit one's open recreational space in the front-yard does not authorize a use or activity which is not authorized by the code. Explain why the granting of the variance is consistent with the general purpose and intent of the General Plan and any applicable specific or Master Plans: The proposed use is a two-family dwelling, consistent with the Residential High (RH) Density designation as discussed above. If located within the coastal zone, explain why the variance is consistent with and implements the requirements of the certified local coastal program and that the variance does not reduce or in any manner adversely affect the protection of coastal resources. P-4 The granting of a variance is consistent with and implements the requirements of the Local Coastal Program and will not have an adverse effect on coastal resources and will have no impacts on sensitive environmental resources. Therefore, granting such a variance will not adversely affect the Local Coastal Program. Page 4 of 4 Revised 04/15 ATTACHMENT 17 DESCRIPTIVE EXPLANATION AND JUSTIFICATION FOR GRANTING A VARIANCE The proposed project is located on Carlsbad Boulevard where all the lots on the entire block have no vehicle access directly onto Carlsbad Blvd. Instead all the lots get their access from alleys, which are accessed from either of the two side streets. The proposed site's access is by means of a rear 20 ft. public alley, which besides serving the project site, also provides access for the lots to the south of the site. The alley itself terminates at the proposed site. There a 15 foot wide private easement extends across the entire rear width of the site. None of the adjoining properties, who have easement rights, currently or historically access their properties from the project site. It's a dead-end private street with no outlet(s}, and that no one but the proposed project owner need to cross in order to access their property. The lot to the north has its access from the adjoining side street. The Planning code essentially only addresses vehicle access from the 'front' street, which in our case, is for all practical purposes, is prohibited. Therefore, the only way then to have any vehicle access is to utilize the rear alley, which is what all but one of the lots on the block already do. Therefore, the rear (alley) access is consistent with the existing pattern of site development. This creates a situation where the 'normal' tendency to locate the required private open recreational space(s) in the rear yard is not possible because that space has significant use restriction which limit the permitted uses to only providing access to the private enclosed garages and the guest pa rking. In addition, the site is blessed with having an outstanding view of the ocean from the front yard. Without the need to provide for a driveway and guest parking, the entire front yard area is now available for use as open recreational area. The proposed design is to locate a 348 square foot 'garden patio', surround by a series of low walled landscape walls that provide visual and acoustical privacy. The proposed open recreational space is only 32 percent of the front-yard setback area. The granting of this variance is in keeping with the spirit and intent of the planning code, makes for good architectural and community engagement designs, and is in keeping with the existing use pattern of similar properties lots fronting on that sect ion of Carlsbad Blvd., to use their front yards as open recreational areas. Who in their right mind, would locate the private recreational space to rear yard, and not take advantage of the view? This variances only allow us to achieve the same uses that are already granted to all the other properties on the block, and the street. ATTACHMENT 12 APPLICABLE FOR PROJECTS WITH 2-4 HOMES CITY COUNCIL POLICY 44-NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES Architectural Guideline I Compliance Comments Floor Plans and Elevations 1 All residential projects shall be required to have a minimum number The proposed deviation is to of different floor plans, different front and corresponding matching provide: 1) two different floor rear elevations with different color schemes as identified below: plans, and 2) one single ~ 2-4 dwelling units shall provide 1 floor plan and 2different integrated exterior elevation □ elevations. design that creates a visual 5-12 dwelling units shall provide 2 different floor plans and 2 impression of a single two- □ different elevations. story single-family home, and 13-20 dwelling units shall provide 2 different floor plans and 3 not that of a two-story different elevations. stacked-flat apartment 21+ dwelling units shall provide 3 different floor plans and 3 building different elevations. 2 Every house shou ld have a coherent architectural style. All elevations Breakers' View building is an of a house, including front, side and rear, should have the same updated version of the Arts & design integrity of forms, details and materials. Craft Prairie House Stvle 3 In addition to the previous requirements, design details should reinforce and enhance the arch itectural form and style of every house The proposed two-family home and differ from other elevations of the same floor plan. A minimum of incorporates all eight of the 4 complimentary design details, including but not limited to those design details listed. listed below, shall be incorporated into each of the front, rear and lwleet side building fa~ade(s) of tWouse. ~ Desig~etails D Balconies □ Knee braces D Decorative eaves and fa scia □ Dormers Exposed roof rafter tails Columns Arched elements Exterior wood elements Towers Accent materials (i.e.; brick, stone, shingles, wood or siding) 4 Floor plans in a project shall exhibit a variety of roof ridges and roof heights within a neighborhood. ATTACHMENT 12 CITY COUNCIL POLICY 44 -NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES Architectural Guideline Compliance Comments Single Story Requirements 9 The remaining total number of homes shall comply with one of the following guidelines: Building perimeter= 266 l.f. □ The home shall have a single-story building edge with a depth of SSBE req'd 266x.40 = 106 l.f. not less than 8 feet and shall run the length of the building along one side except for tower elements. The roof covering the SSBE provided = 1101.f. single-story element shall incorporate a separate roof plane and shall be substantially lower than the roof for the two-story < Complies element. Porches and porte-cochere elements shall qualify as a single-story edge. Houses with courtyards that are a minimum of 15 feet wide located along the side of the house and setback a minimum of 15 feet from the property line are not required to have a single-story building edge. Multiple Building Planes 10 For at least 66% of the homes in a project, there shall be at least 3 Project complies. separate building planes on street side elevations of lots with 45 feet of street frontage or less and 4 separate building planes on street side elevations of lots with a street frontage greater than 45 feet. Balconies and covered porches qualify as a building plane. The minimum offset in planes shall be 18 inches and shall include, but not be limited to, building walls, windows, porches and roofs. The minimum depth between the faces of the forward-most plane and the rear plane on the front elevation shall be 10 feet. A plane must be a minimum of 30 sq. ft . to receive credit under this section. 11 Rear elevations shall adhere to the same criteria outlined in Number Project complies. 10 above for front elevations except that the minimum depth between front and back planes on the rear elevation shall be 4 feet. Rear balconies qualify as a building plane. Windows/Doors 13 At least 66% of exterior openings (door/windows) on every home in 100% or ALL CXTCRIOR OPCNINGS the project shall be recessed or projected a minimum of 2 inches and ARC RCCCSSCD OR PROJECTCD. & shall be constructed with wood, vinyl or colored aluminum window HAVE MANUFACTURED NON MILL frames (no mill finishes). rlNISJ-l[S 14 Windows shall reinforce and enhance the architectural form and style Project complies. of the house through, the use of signature windows and va ried window shapes and sizes. ' ,, ATTACHMENT 12 CITY COUNCIL POLICY 44 -NEIGHBORHOOD ARCHITECTURAL DESIGN GUIDELINES CONTINUED Architectural Guideline Compliance Comments Front Porches 15 Fifty percent (50%) of the homes shall be designed with a covered Project complies. front porch, open courtyard, or balcony (each with a minimum depth of 6 feet and a minimum area of 60 square feet) located at the front of the dwelling. The minimum depth for a covered front porch shall be measured from the front fac;:ade of the home to the inside of any supporting porch posts. The front and sides of porches shall be open except for required and/or ornamental guardrails. A variety of roof elements shall be provided over porches. Porches may not be converted to living space. Front Entries 16 Seventy-five percent (75%) of the homes must have a front entry to Project complies. the home that is clearly visible from the street. Walkways from the front door to the street are encouraged. Chimneys 17 Chimneys and chimney caps shall be in scale with the size of the No chimneys. home. No more than 2 chimneys shall be allowed for homes on lots in planned developments having an area less than 7,500 square feet. Garage Doors 18 Garage doors for 3 or 4 cars in a row that directly face the street NA must have a minimum of an 18" plane change between the garage doors after the 2 car garage door. Note #1 : Fractional units of .5 or greater shall be rounded up to the next whole number and located in a manner to achieve the best project design as determined by the project planner. When a percentage of units are described in the guidelines, the intent is to have that percentage spread throughout the entire project. 2 3 4 5 ATTACHMENT 13 CITY COUNCIL POLICY 66 -LIVABLE NEIGHBORHOODS Principle Building Facades, Front Entries, Porches Facades create interest and character and should be varied and articulated to provide visual interest to pedestrians. Clearly identi fiable front doors and porches enhance the street scene and create opportunities for greater social interaction within the neighborhood. Building entries and windows should face the street. Front porches, bay windows, courtyards and balconi es are encouraged. Garages Homes should be designed to feature the residence as the prominent part of the str ucture in relation to the street. A variety of garage configurations should be used to improve the street scene. This may include tandem garages, side-loaded garages, front- loaded garages, alley-loaded garages and recessed garages. Street Design An interconnected, modified (grid) street pattern should be incorporated into project designs when there are no topographic or environmental constraints. Interconnected streets provide pedestrians and automobiles many alternative routes to fo llow, disperse traffic and reduce the volume of cars on any one street in the neighborhood. Streets should be designed to provide both vehicular and pedestri an connectivity by minimizing the use of cul- de-sacs. The street network should also be designed to create a safer, more comfortable pedestrian and bicycl ing environment. Local residential streets should have travel and parking lanes, be sufficiently narrow to slow traffic, provide adequate access for emergency and service vehicles and emergency evacuation routes for residents and include parkways with trees to form a pleasing canopy over the street. Local residential streets are the public open space in which children often play and around which neighborhoods interact. Within this context, vehi cular movement should be additionally infl uenced through the use of City-accepted designs for traffic calming measures. Parkways Street trees should be planted in the parkways along all streets. Tree species should be selected to create a unified image for the street, provide an effective canopy, avoid sidewalk damage and minimize water consumption. Pedestrian Walkways Pedestrian walkways should be located along or visible from all streets. Walkways (sidewalks or trails) should provide clear, comfortable and direct access to neighborhood schools, parks/plazas and transit stops. Primary pedestrian routes should be bordered by residential fronts, parks or plazas. Where street connections are not feasible (at the end of cul-de-sacs), pedestrian paths should also be provided. Compliance Comments ALL FEATURES PROV ID ED. SEE 3D PHOTO REALISTIC RENDERINGS A 'JD EXTERIOR ELEVATIONSL. ALL PROVI OED. SEE NOTE ABOVE NA -UNLESS REQ'D. 0 SIGNIFICATE PUBLIC STREET WORK IS PROPOSED OTH ER THA TO REPLACING THE EX ISTING SU BSTAN DARD CURB, GUTTER & SIDEWALK, A. D TO PROVIDE STREET TREES. PLEAS E PROVIDE PERFERR ED STREET T REE LOCATIONS GIVE TH E LACK OF ANY PARKW AY. PROVIDED. ATTACHMENT 13 6 Centralized Communit:i:: Recreation Areas NA-NO CE TRALIZED Park or plazas, which serve as neighborhood meeting places and as COMMUNITY RECREAT IONAL recreational activity centers should be incorporated into all planned AREAS ARE PROPOSED. unit developments. As frequently as possible, these parks/plazas should be designed for both active and passive uses for residents of all ages and should be centrally located within the project. Parks and plazas should be not be sited on residual parcels, used as buffers from surrounding developments or to separate buildings from streets. ATTACHMENT 14 PLANNED DEVELOPMENTS (CMC SECTION 21.45.060) TABLE C: GENERAL DEVELOPMENT STANDARDS APPLICABLE TO ALL PLANNED DEVELOPMENTS REF. SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT NO. Per the underlying General Plan designation. When two or more general C.1 Density plan land use designations exist within a planned development, the density N/A may be transferred from one general plan designation to another with a general plan amendment. All dwelling units adjacent to any arterial road shown on the Circulation Element of the General Plan shall maintain the following minimum setbacks from the right-of-way: Prime Arterial 50 Feet 20 FT FRONT SETBACK PROVIDED Major Arterial 40 Feet Secondary Arterial 30 Feet Carlsbad Boulevard 20 Feet Half {50%) of the required arterial setback area located closest to the Arterial arterial shall be fully landscaped to enhance the street scene and buffer C.2 Setbacks homes from traffic on adjacent arterials, and: SEE LANDSCAPE DWGS -REQ'D • Shall contain a minimum of one 24" box tree for every 30 lineal feet PLANTING TO BE PROVIDED of street frontage; and • Shall be commonly owned and maintained Project perimeter walls greater than 42 inches in height shall not be located in the required landscaped portion of the arterial setback, except noise attenuation walls that: MAX WALL HIGHT IN FRONT • Are required by a noise study, and SETBACK IS 42" • Due to topography, are necessary to be placed within the required landscaped portion of the arterial setback. Permitted Intrusions Permitted intrusions into required building setbacks shall be the same as into 2 FT MAX INTRUSIONS INTO ALL C.3 Setbacks/ specified in Section 21.46.120 of this code. The same in trusions specified in SETBACKS PER CODE Building Section 21.46.120 shall be permitted into required building separation. Separation Minimum right-of-way width 56feet Minimum curb-to-curb width 34 feet Private Minimum parkway width 5.5 feet, including curb NA (curb adjacent) Minimum sidewalk width 5 feet (setback 6 inches from property line) Minimum right-of-way width 60feet C.4 Streets Minimum curb-to-curb width 34feet Public Minimum parkway width 7.5 feet, including curb NA (curb adjacent) Minimum sidewalk width 5 feet (setback 6 inches from property line) Street A minimum of one street tree THERE IS NO PARKWAY -ONLY 6 FT Trees One-family dwellings and (24-inch box) per lot is required SIDEWALK. PLEASE IDENTIFY within twin homes on small-lots to be planted in the parkway LOCA TION(S) parkways along all streets. ATTACHMENT 14 Street trees shall be spaced no SEE LANDSCAPE DWGS -REQ'D Condominium projects further apart than 30 feet on PLANTING TO BE PROVIDED center within the parkway. Tree species should be selected to create a unified image for the PROVIDED street, provide an effective canopy, avoid sidewalk damage and SEE LANDSCAPE DWGS minimize water consumption. 3 or fewer Minimum 12 feet wide when the drive-aisle is not required for 30 FT. WIDE DRIVE AISLE ACCESSED emergency vehicle access, as determined by the Fire Chief. dwelling If the drive-aisle is required for emergency vehicle access, it THRU EXIST'G 15 FTWIDE ALLEY units shall be a minimum of 20 feet wide. PROVIDED 4 or more dwelling Minimum 20 feet wide. NA units No parking shall be permitted within the minimum required YES width of a drive-aisle. C.5 Drive-aisles A minimum 24-foot vehicle back-up/maneuvering area shall be 30 FT. DRIVEWAY/ BACKUP AREA provided in front of garages, carports or uncovered parking PROVIDED spaces (this may include driveway area, drive-aisles, and All streets). projects Additional width may be required for vehicle/emergency vehicle NA -EXISTING 15 FT. WIDE ALLEY maneuvering area. Parkways and/or sidewalks may be required. NA -REAR ALLEY/ NOT A STREET No more than 24 dwelling units shall be located along a single-NA entry drive-aisle. All drive-aisles shall be enhanced with decorative pavement. YES Number of Projects with 10 units or fewer I A .30 space per each unit. Visitor Projects 11 units or more I A .25 space per each unit. C.6 Parking When calculating the required number of visitor parking spaces, if the REQ'D SPACES = .6 = 1 Spaces calculation results in a fractional parking space, the required number of SPACES PROVIDED= 2 Required 111 visitor parking spaces shall always be rounded up to the nearest whole number. On-street visitor parking is permitted on private/public streets, NA subject to the following: • The private/public street is a minimum 34-feet wide (curb-to- curb) • There are no restrictions that would prohibit on-street parking where the visitor parking is proposed • The visitor parking spaces may be located: 0 Along one or both sides of any private/public street(s) On located within the project boundary, and Location of Private/ 0 Along the abutting side and portion of any existing C.7 Visitor Public public/private street(s) that is contiguous to the project Parking Streets boundary In parking bays along public/private streets within the project NA boundary, provided the parking bays are outside the minimum required street right-of-way width. When visitor parking is provided as on-street parallel parking, NA not Jess than 24 lineal feet per space, exclusive of driveway/drive-aisle entrances and aprons, shall be provided for each parking space, except where parallel parking spaces are located immediately adjacent to driveway/drive-aisle aprons, then 20 lineal feet may be provided. ATTACHMENT 14 Within the Beach Area Overlay Zone, on-street parking shall not YES count toward meeting the visitor parking requirement. On Drive-Visitor parking must be provided in parking bays that are YES -45 DEGRESS ANGLED aisles located outside the required minimum drive-aisle width. PARKING One required visitor parking space may be credited NA Outside for each driveway in a project that has a depth of the Beach 40 feet or more. Area For projects with 10 or fewer units, all required ALL VISITOR PARKING LOCATED IN Overlay visitor parking may be located within driveways FRONT OF UNIT'S GARAGE DOOR. Zone (located in front of a unit's garage), provided that 30 FT. DRIVEWAY all dwelling units in the project have driveways with a depth of 20 feet or more. One required visitor parking space may be credited for each driveway in a project that has a depth of NA 40 feet or more. If the streets within and/or adjacent to the project allow for on-street parking on both sides of the street, then visitor parking may be located in a driveway, subject to the following: Within • All required visitor parking may be located Ona the Beach within driveways (located in front of a unit's Driveway Area garage), provided that all dwelling units in the Overlay project have driveways with a depth of 20 feet Zone or more. NA • If less than 100% of the driveways in a project have a depth of 20 feet or more, then a .25 visitor parking space will be credited for each driveway in a project that has a depth of 20 feet or more (calculations resulting in a fractional parking space credit shall always be rounded down ta the nearest whole number). The minimum driveway depth required for visitor parking (20 feet or 40 feet) applies to driveways for All front or side-loaded garages, and is measured from 30 FT. DRIVEWAY projects the property line, back of sidewalk, or from the edge of the drive-aisle, whichever is closest to the structure. For projects of more than 25 units, up to 25% of visitor parking may be provided as compact spaces (B feet by 15 feet). No NA Compact overhang is permitted into any required setback area or over sidewalks less than 6 feet wide. Parking For all projects within the Beach Area Overlay Zone, up to 55% of the visitor parking may be provided as compact spaces (B feet 2 STANDARD SPACES PROVIDED by 15 feet). Distance Visitor parking spaces must be located na more than 300 feet as from unit measured in o logical walking poth from the entrance of the NA unit it could be considered to serve. Screening of Open parking areas should be screened from adjacent residences and PARKING AREA SHALL HAVE A 6 FT C.8 Parking public rights-of-way by either a view-obscuring wall, landscaped berm, or HIGH FENCING Areas landscaping, except parking located within a driveway. C.9 Community recreational space shall be provided for all projects of 11 or NA -under 11 units. more dwelling units, as follows: ATTACHMENT 14 Project is NOT within R- Minimum community 23 general plan 200 square feet per unit designation recreational space Project IS within R-23 required general plan 150 square feet per unit designation Projects with 11 to Community recreational space shall be provided as either (or both) passive or active recreation NA 25 dwelling units facilities. Community recreational space shall be provided as Projects with 26 or both passive and active recreational facilities with a NA more dwelling units minimum of 75% of the area allocated for active facilities. Community recreational space shall be provided as both passive and active recreational facilities for a NA variety of age groups (a minimum of 75% of the area allocated for active facilities). For projects consisting of one-family dwellings or Projects with 50 or twin homes on small-lots, at least 25% of the community recreation space must be provided as more dwelling units pocket parks. • Pocket park lots must have a minimum width of NA Community 50 feet and be located at strategic locations such as street intersections (especially "T-Recreational intersections") and where open space vistas may Space 111 be achieved. Community recreational space shall be located and designed so as to be functional, usable, and easily NA accessible from the units it is intended to serve. Credit for indoor recreation facilities shall not All projects exceed 25% of the required community recreation NA (with 11 or more area. Required community recreation areas shall not be dwelling units) located in any required front yard and may not include any streets, drive-aisles, driveways, parking NA areas, storage areas, slopes of 5% or greater, or walkways (except those walkways that are clearly integral to the design of the recreation area). In addition to required resident and visitor parking, recreation area parking shall be provided, as follows: 1 space for each 15 residential units, or NA Recreation Area fraction thereof, for units located more than 1,000 feet from a community recreation area. Parking The location of recreation area parking shall be subject to the same location requirements as for NA visitor parking, except that required recreation area parking shall not be located within a driveway(s). Examples of recreation facilities include, but are not limited to, the following: ATTACHMENT 14 Swimming pool area Children's playground equipment Spa Courts (tennis, racquetball, volleyball, basketball) Recreation rooms or buildings Active Horseshoe pits Pitch and putt Grassy play areas with a slope of less than 5% (minimum area of 5,000 square feet and a minimum dimension of 50 feet) Any other facility deemed by the City Planner to satisfy the intent of providing active recreational facilities Benches Passive Barbecues Community gardens Grassy play areas with a slope of less than 5% C.10 Lighting Lighting adequate for pedestrian and vehicular safety shall be provided. YES -SEE 3D RENDERINGS C.11 Reserved Required for projects with 100 or more units, or a master or specific plan with 100 or more planned development units. Exception: RV storage is not required for projects located within the R-15 or R-23 land use designations. 20 square feet per unit, not ta include area required for driveways and NA -under 100 units approaches. Developments located within master plans or residential specific plans may have this requirement met by the common RV storage area provided by the Recreational master plan or residential specific plan. C12 Vehicle (RV) RV storage areas shall be designed to accommodate recreational vehicles Storage 111 of various sizes (i.e. motorhomes, campers, boats, personal watercraft, NA etc.). The storage of recreational vehicles shall be prohibited in the front yard setback and on any public or private streets or any other area visible to the public. A provision containing this restriction shall be included in the NA covenants, conditions and restrictions for the project. All RV storage areas shall be screened from adjacent residences and public rights-of-way by a view-obscuring wall and landscaping. 480 cubic feet of separate storage space per unit. if all storage for each unit is located in one area, the space may be reduced NA -PR/VA TE GARGES PROVIDED to 392 cubic feet. Required storage space shall be separately enclosed for each unit and be NA conveniently accessible ta the outdoors. C.13 Storage Required storage space may be designed as an enlargement of a covered Space parking structure provided it does not extend into the area ofthe required NA parking stall, and does not impede the ability to utilize the parking stall (for vehicle parking). A garage (12'x20' one-car, 20'x20' two-car, or larger) satisfies the required TWO 20'X19' PR/VA TE GARAGES storage space per unit. PROVIDED This requirement is in addition to closets and other indoor storage areas. NA Ill This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). ATTACHMENT 15 PLANNED DEVELOPMENTS (CMC SECTION 21.4S.080) TABLE E: CONDOMINIUM PROJECTS REF. SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT NO. Livable Must comply with City Council Policy 66, Principles for the Development E.l Neighborhood SEE SEPARATE COMPLIANCE CHART Policy of Livable Neighborhoods. One-family and Must comply with City Council Policy 44, Neighborhood two-family SEE SEPARATE COMPLIANCE CHART dwellings Architectural Design Guidelines There shall be at least three separate building planes on all building elevations. The minimum offset in planes NA shall be 18 inches and shall include, but not be limited to, building walls, windows, and roofs. All building elevations shall incorporate a minimum of four complimentary design elements, including but not limited to: • A variety of roof planes; E.2 Architectural • Windows and doors recessed a minimum of 2 inches; Requirements Multiple-family • Decorative window or door frames; dwellings • Exposed roof rafter tails; • Dormers; Columns; NA • • Arched elements; • Varied window shapes; • Exterior wood elements; • Accent materials such as brick, stone, shingles, wood, or siding; • Knee braces; and • Towers . E.3 Maximum 60% of total project net developable acreage. Coverage Same as required by the underlying zone, and not to exceed three stories 2 STORIES ON GRADE -PROPOSED (1)(7) Projects 40 feet, if roof pitch is 3: 12 or greater E.4 Maximum within the R-35 feet, if roof pitch is less than 3:12 Building Height 23 general NA -BAOZ 30' /24' plan designation Building height shall not exceed three stories (1)(7) From a Residential 10 feet 20 FT FRONT @ RESIDENTIAL private or structure GARAGE ENTRY IS FROM REAR ALLY- public Direct entry 20 feet NO AUTO ACCESS FROM CARLSBAD street12H3l garage BLVD Residential 5 feet, fully landscaped (walkways structure Minimum (except as providing access to dwelling entryways NA -25 units or less. See below. E.S Building specified may be located within required Setbacks below) landscaped area) From a drive-Residential aisle141 structure -0 feet when projecting over the front of a directly NA -25 units or less. See below. above a garage. garage Garage 3 feet NA -25 units or less. See below. ATTACHMENT 15 PLANNED DEVELOPMENTS (CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF. SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT NO. Garages facing directly onto a drive-aisle shall be equipped with an automatic garage door opener. Projects of 25 0 feet (residential structure and garage) units or less within the R-Garages facing directly onto a drive-aisle ALL GARAGES TO HAVE AUTOMATIC 15 and R-23 shall be equipped with an automatic GARAGE DOOR OPENER general plan garage door opener. designations 0 feet May cantilever over a drive-aisle, Balconies/deck provided the balcony/deck complies with s (unenclosed all other applicable requirements, such as: and Setbacks from property lines • uncovered) • Building separation • Fire and Engineering Department requirements From the perimeter property The building setback from an interior side lines of the project site (not or rear perimeter property line shall be adjacent to a public/private the same as required by the underlying zone for an interior side or rear yard street) setback. Minimum E.6 Building 10 feet Separation If a project is located within the R-23 general plan designation, resident parking shall be provided as All dwelling specified below, and may also be provided as follows: • 25% of the units in the project may include a tandem types two-car garage (minimum 12 feet x 40 feet). • Calculations for this provision resulting in a fractional unit may be rounded up to the next whole number. 2 spaces per unit, provided as either: • a two-car garage (minimum 20 feet x 20 feet), or One-family • 2 separate one-car garages (minimum 12 feet x 20 and two- family feet each) Resident dwellings • In the R-W Zone, the 2 required parking spaces may E.7 Parking (5I be provided as 1 covered space and 1 uncovered space (SI 1.5 spaces per unit, 1 of which must be covered l5I Studio and When calculating the required number of one-bedroom parking spaces, if the calculation results NA Multiple-units in a fractional parking space, the family required number of parking spaces shall dwellings always be rounded up to the nearest whole number. Units with two or more 2 spaces per unit, provided as either: NA bedrooms ATTACHMENT 15 PLANNED DEVELOPMENTS {CMC SECTION 21.45.080) TABLE E: CONDOMINIUM PROJECTS REF. SUBJECT DEVELOPMENT STANDARD COMPLIANCE COMMENT NO. • a one-car garage (12 feet x 20 feet) and 1 covered or uncovered space; or (5) • a two-car garage (minimum 20 feet x 20 feet), or • 2 separate one-car garages (minimum 12 feet x 20 feet each) • In the R-W Zone and the Beach Area Overlay Zone, the 2 required parking spaces may be provided as 1 covered space and 1 uncovered space (51 Required parking may be provided within an enclosed parking garage with multiple, open parking spaces, subject to the following: • Each parking space shall maintain a standard stall size of 8.5 feet by 20 feet, exclusive of supporting NA columns; and • A backup distance of 24 feet shall be maintained in addition to a minimum 5 feet turning bump-out located at the end of any stall series. Required resident pa rking spaces shall be located no more than 150 feet as measured in a logical walking NA path from the entrance of the units it could be considered to serve. Required private recreational space shall be designed so as to be functional, usable, and easily accessible from One-family, the dwelling it is intended to serve. two-family, Required private recreational space shall be located and multiple-adjacent to the unit the area is intended to serve. family Required private recreational space shall not be located dwellings within any required front yard setback area, and may not include any driveways, parking areas, storage areas, or common walkways. Projects not within the R-400 square Minimum 15 or R-23 general plan feet designations total area Projects within the R-15 or Private per unit 200 square E.8 Recreational R-23 general plan feet Space designations May consist of more t han one recreational space. One-family May be provided at ground level and/or as a and two-deck/balcony on a second/third floor or roof. family Not within dwellings the R-15 or R- 23 general 15 feet If provided Minimum plan at ground designations level dimension Within the R- 15 or R-23 10 feet general plan designations • ATTACHMENT 15 PLANNED DEVELOPMENTS (CMC SECTION Zl.45.080} TABLE E: CONDOMINIUM PROJECTS REF. SUBJECT NO. DEVELOPMENT STANDARD COMPLIANCE COMMENT Shall not have a slope gradient greater than 5%. Attached solid patio covers and decks/balconies may project into a required private recreational space, subject to the following: • The depth of the projection shall not exceed 6 feet (measured from the wall of the dwelling that is contiguous to the patio/deck/balcony). The length of the projection shall not be limited, except as required by any setback or lot coverage standards. Open or lattice-top patio covers may be located within the required private recreation space (provided the patio cover complies with all applicable standards, including the required setbacks). If provided Minimum dimension 6 feet above ground level as a 60 square deck/ balcony Minimum area feet or roof deck Minimum total area per unit (patio, 60 square NA porch, or balcony) feet Minimum dimension of patio, porch or 6 feet NA balcony Multiple-family Projects of 11 or more units that are within the R-23 dwellings general plan designation may opt to provide an additional 75 square feet of community recreation space NA per unit (subject to the standards specified in Table C of this Chapter), in lieu of providing the per unit private recreational space specified above. 111 If a project is located within the Beach Area Overlay Zone, building height shall be subject to the requirements of Chapter 21.82 of this code. 121 See Table C in Section 21.45.060 for required setbacks from an arterial street. 131 Building setbacks shall be measured from the outside edge of the required street right-of-way width, whichever is closest to the building. l4l Building setbacks shall be measured from one of the following (whichever is closest to the building): a) the outside edge of the required drive-aisle width; b) the back of sidewalk; or c) the nearest side of a parking bay located contiguous to a drive- aisle (excluding parking located in a driveway in front of a unit's garage). l5l Any uncovered required parking space in the R-W zone may be located within a required front yard setback and may be tandem. 161 This standard does not apply to housing for senior citizens (see Chapter 21.84 of this code). l7l Protrusions above the height limit shall be allowed pursuant to Section 21.46.020 of this code. Such protrusions include protective barriers for balconies and roof decks. ATTACHMENT 16 TRANSPACIFIC ARCHITECTS 888 O'FARRELL STREET , TRINITY TOWERS S U ITE W606, SA N FRANCISCO , CA 9 4 109 415.844.0783 MAY l, 2018 PLANNING DEPARTMENT Community & Economic Development, City of Carlsbad 1635 Faraday Avenue, CA 92008-7314 SUBJECT: Applicant Proposal for an Architectural Style that Complies with the Purpose and Intent of Policy 44, for PUD,SDP,CDP, BREAKERS VIEW CARLSBAD This documentation demonstrates the proposed project's compliance with the purpose and intent the Council Policy 44 allowing for an alternative architectural style The proposed two-family residential air- space condominium project proposes a deviation to the architectural guideline #1 of City Cou ncil Policy No.44 which states: All residential projects shall be required to have a minimum number of different floor plans, different front and corresponding matching rear elevations with different color schemes, ... and 2- 4 unit dwellings shall provide 1 floor plan and 2 different elevations. Policy 44 is geared toward multiple, one-family or multiple two-family developments projects where multiple buildings are proposed in close proximity. The policy does not apply to one, single-family home. However, it technically applies to one, two-family homes. The policy would not apply to a multiple-family building containing three or more units. City Council Policy 44 allows a project to propose an architectural style that complies with the purpose and intent of the policy which states: 'The purpose and intent of the architectural guidelines is t o ensure that a variety of architectural elements are incorporated into sin gle-family homes and two-family structures so that they: a) are visually interesting, b) have sufficient building articulation to reduce their bulk and mass, c) are in scale to their lot size, and d) strongly contribute to the creation of livable neighborhoods.' 1 ATTACHMENT 16 ARCHITECTURAL GUIDELINES 1 . 0 THE ARCHITECTURAL STYLE of the Breakers' View building is an updated version of the Arts & Craft Prairie House Style. The two-story Pallas Verde stone building, ninety- one feet long, has three nearly continuous horizontal bands, at three different vertical locations, and on every building elevations. This strong horizontal elements give structural theme and design unity to each and every building elevation. These long low layered lines reflect the shapes of where land and sea intersect and are expressed in the interplay of roof, balcony and landscape planter wall elements and the vertically of key architectural elements, together producing a dynamic and graceful cohesive architectural design. The first band is located at grade level and is a series of low, exposed architectural-grade concrete landscape- planter walls, which are essential to forming a strong visual foundational-base where the building appears to have organically grow out of the site, (and not just dropped down on a flat lot), and thus integrating the building design and the site design into a unified whole. The second band is the required Policy 44 -Single Story Building Edge. (Guideline #9.c option used) Again, this element is also comprised of three primary parts. The first part, is the 'clerestory awning'. This element is key to setting a human scale to the architecture, and a signature design feature of the Prairie House style -eliminating the 'headers' or short pieces of wall that extend between the top of the doors or windows, and where they meet the ceiling/ floor assembly that is above them. The first floor has a ceiling height of eleven-feet, a floor-to-floor height of twelve-feet, and with eight- foot opening heights at all doors and windows, which leaves a problematic four-foot high section of header- wall. This is resolved by replacing the 'header' with a twelve-inch thick, by eighteen-inch deep, low-roof element or 'clerestory awning roof' element, then replacing the piece of 'short-wall' with clerestory windows, that fill the space between the top of clerestory awing and the bottom of the floor/ ceiling 2 assembly above. The second part of the Single Story Building Edge band, is the cantilevering of the second floor framing out two-feet beyond the exterior walls, thereby creating a first floor roof edge. The eighteen- inch high, two-part, accent colored, and stepped clerestory awning roof fascia assembly integrates the first floor roof with the clerestory awning below and the balcony guardrails above. The third part of the Single Story Building Edge band are the second-floor balcony guardrails, who's color accented wall-caps and wrought iron decorative handrails, provide a ATTACHMENT 16 cohesive design detail, that simultaneously allows for accommodating changes in floor plans and exterior elevations, and still maintains overall architectural design consistency. The third band are the flat-roofs / roof-decks over the second-floor. Repeating the same thickness, profile, color scheme, and cantilever distance as the first floor roof edge, the second floor lower roof lines unifies the massing of building and emphases the horizontal lines of the building. 1 . 1 TH E E NT RY to the project is from Carlsbad Boulevard for pedestrians, vehicles gain access to the garages and guest parking through the rear alley that is entered off Juniper Avenue. There are separate pedestrian decorative walkways extending from the public sidewalk to private covered entry porches for each unit, and each entry is located on separate sides of the building. When viewed from the front, only one unit entry can be seen at time, giving the impression that the building is a single family home. Unit One's entry is on the North side, and Unit Two's entry in on the South side. The entry walkways are separated from the first -floor front-yard recreational view patio by architectural concrete landscape planters that provide both physical and visual privacy from the walkways, as well as Carlsbad Blvd. Both entryways extend from the front street to the rear guest parking and driveway areas. Two pedestrian gates provide access control to the walkways, as a legacy (1926) private driveway access easement precludes providing a driveway access control gate at the public alley, and thereby insuring the complete inability to properly secure the site. 1 . 2 f L O O R P LA N S A N D E L EV AT I O N S The proposed two-family residential air-space condominium project proposes a deviation to the architectural guideline #1 of City Council Policy No.44 which states: All residential projects shall be required to have a minimum number of different floor plans, different front and corresponding matching rear elevations with different color 3 schemes ... , ... 2-4 unit dwellings shall provide 1 floor plan and 2 different elevations. Policy 44 is geared toward multiple, one-family or multiple two-family developments projects where multiple buildings are proposed in close proximity. The policy does not apply to one, single-family home. However, it technically applies to one, two-family homes. The policy would not apply to a multiple-family building containing three or more units. ATTACHMENT 16 City Council Policy 44 allows a project to propose an architectural style that complies with the purpose and intent of the policy which states: 'The purpose and intent of the architectural guidelines is to ensure that a variety of architectural elements are incorporated into single-family homes and two-family structures so that they: a) are visually interesting, b) have sufficient building articulation to reduce their bulk and mass, c) are in scale to their lot size, and d) strongly contribute to the creation of livable neighborhoods.' The proposed deviation is to provide: 1) two different floor plans, and 2) one single integrated exterior elevation design that creates a visual impression of a single two-story single-family home, and not that of a two-story stacked-flat apartment building. The proposed floor plans and elevation designs meet the purpose, intent and all other requirements of the Policy 44. Below are the justifications for the deviation and an illustration of how compliance will be achieved. 1.3 THE FLOOR PLAN for each of the two units is comprised of two parts, a front section of the building that faces directly onto Carlsbad Boulevard with unobstructed white-water ocean views from both units, and a rear section that opens onto a public ally for vehicle access, a driveway for two enclosed garages and guest parking. The front portion of the building is arranged in a two-story 'stacked-flats' configuration. The rear portion of the building is arranged in a two-story, side-by-side, town-house configuration. The stacked flat configuration of the front portion of the building was to insure that both units had full and equal ability to take advantage of the outstanding beach views. Doing this gives each unit the same plus forty-foot wide unobstructed view from their great-rooms, patio or balcony and roof deck. The town-house configuration of the rear portion of the building allows for two side-by-side two-car enclosed garages, first and second floor bedrooms and baths, individual stairs, private elevators, separate roof decks, and most importantly, separate street facing entry walkways with covered entry porches. While the floor plan for rear portion of the building is the same for both units, by necessity, the floor plan for each unit in the front portion must be different to accommodate the separate street entryways, since they are on opposite sides of the building. Unit One's entry in on the north side, and Unit Two's is on the south side. 4 ATTACHMENT 16 1.4 THE EXTERIOR ELEVATIONS as proposed clearly meet the requirements of Policy 44 which states: 'Every house should have a coherent architectural style. All elevat ions of a house, including front, side and rear, should have the same design integrity of forms, details and materials. The discussion above in the Architectural Style section above describes in detail how compliance is to be achieved. But a more significant issue is what consideration should be given for the fact that the project is acting as a buffer between the forty-five foot high, three and one-half stories condo building immediately to the south and the more residential scaled two-story single-family and multiple residential units extending t o the north. 2.0 To minimize the impact of the proposed project on the property immediately adjoining to the north, the higher slopped roof has been setback between seven and twelve feet from the edge of the lower roof, and t hirty-feet from the rear property line. A R C H I T E C T U R A L M A T E R I A L S A N D D E TA I L S Th e proposed two-family building provides covered first level porches, en tryways and patio's, second story ba lconies and third story roof decks. The building has a variety of materials consisting of tan stucco, stone and tile veneer, met al clad wood fascia, recessed metal-clad casement window, entry & sliding doors, and exterior bi-fold doors. A standing seam metal roof with a 3:12 pitch covers a portion of the building. Low landscape walls in conjunction with the second floor balcony's two-part wood capped 5 2.1 DESIGN DETAILS ATTACHMENT 16 stucco pony wall with wrought iron railing and the roof deck's high-profiled metal-clad fascia edge with decorative wrought iron railing are include around the building at various location and emphases the horizontal lines of the building. Residential projects as per Policy 44 require a minimum of four out of the eight following architectural design details. The proposed two-family home incorporates all eight of the design details listed. 1-Second-floor balconies and roof decks have two-part guardrails. Each guardrails has a lower two-foot high wood-framed pony wall, with an attached, eighteen-inch high wrought iron decorative handrail, with an overall total height of forty-two inches. 2-Exposed architectural concrete structural-tower structures, incorporating fireplaces, fire pits and BBQ's. Towers elements extend from grade level through and above both the lower and upper roofs. These design elements create the strong vertical lines that create the visual design tension between the horizontal and vertical architectural elements. 3-Exposed architectural concrete planter walls at finish grade 4-Custom standing seam metal roof with integral concealed gutters 5-Vertical wood, stucco and concrete pilasters that create recessed doors and window wall panels. 6-Exterior wall finishes that include exposed architectural concrete walls, precast concrete wall panels with architectural concrete or textured wood finishes, wood trim and casings at balcony rails, and exterior wood siding and trim elements 7-Wood and concrete accent materials at walls and roofs 8-Stair and elevator towers with roof deck access and mechanical equipment penthouses. 2.2 ROOF DESIGN & HEIGHTS: The proposed design has three different roof levels. The lowest roof level is comprised of the flat roof area, plus the individual roof decks, has a height of 21 feet (maximum height of 24'-0") and an area of 2,030 square feet (45%). The next roof level is the sloped standing seam metal roof with a 3:12 roof pitch, has a maximum height of 30'-0" and an area of 1,768 square feet (40%}. The third roof level is the stair/elevator penthouse roofs. It is a sloped standing seam metal roof with a 3:12 pitch and a maximum height of 35 feet and has the smallest area of the three at 734 square feet (15%}. 6 0 ATTACHMENT 16 2 .3 POLICY 44 -SINGLE STORY BUILDING EDGE: Architectural Guideline No. 9 -C: a single story building edge element with a minimum width of 3 feet wid e, for 40% of the total building perimeter. Proposed building perimeter= 266 In. ft. x .40 = 106 In . ft. required Single Story Build ing Edge = 110 In. ft. provided MULTIPLE BU IL DING PLANES: There are no fewer than 8 separate building planes on the street/front elevation with offset planes that ra nge from 18 inches to 29 feet in depth. At the rear elevation there are no fewer than 6 separate building planes with offset planes ranging from 2 feet to 17 feet in depth. Both the side elevations have offsets and cutouts that range between 2 feet and 20 feet deep. WI N DOWS AN D DO O RS: In keeping with the architectural style signature Prairie style doors and windows of varied shapes and sizes are utilized. All doors and windows are recessed or projected a minimum of 2 inches and are constructed of pre-finished metal cladding over wood interiors and frames. Thank you for your time and consideration of our and I look forward to your comments. Sincerely yours, Rachel f3LLe H ege S orrow Rachel Elle Hege Sorrow, AIA TR ANS P AC IFI C AR CH IT ECT 7 ~ . (]1 ACHMENT18 AT TA CHMENT 1 8 BREAKERS' VIEW CARLS BAD 304& c.-.,useAO l!I..VO CARLSBAD C.ALIFORNIA 92008 3648 C ARLSBA D B LVD., LL C A3 A 1, •F~ Su 1.: 1 · ;, V~IE-1)1:VIELOVMIENT SIET NOT 1'0~ CONST~UCTION A I I A~HIVll=N I. ·1 ~ 1 OF3 1 -NORTHERLY VIEW OF PROPERTY FROM CARLSBAD BLVD. 2 -NORTH WEST VIEW OF CARLSBAD BLVD. FROM FRONT OF PROPERTY MI I MvnlVIC.l'I I I 0 . . . 20F3 3 -SOUTHERLY VIEW OF CARLSBAD BLVD. FROM FRONT OF PROPERTY 4-NORTHERLY VIEW OF REAR DRIVEWAY FROM JUNIPER A VE. A I I Avt11Vlt:l'JI. I p , 30F3 5 -NORTHERLY VIEW OF ALLEY LO CATED BEHIND PROPERTY FROM JUNIPER A VE. 6 -SOUTHERLY VIEW OF ALLEY FROM REAR DRIVEWAY CHICAGO TITLE COMPANY ATTACHMENT 4 PRELIMINARY REPORT Order No.: Property: 73718004139-PM 3648 Carlsbad Boulevard Carlsbad, CA 92008 In response to the application for a policy of title insurance referenced herein, Chicago Title Company hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a policy or policies of title insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an exception herein or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations or Conditions of said policy forms. The printed Exceptions and Exclusions from the coverage and Limitations on Covered Risks of said policy or policies are set forth in Attachment One. The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than that set forth in the arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. Limitations on Covered Risks applicable to the CL TA and ALT A Homeowner's Policies of Title Insurance which establish a Deductible Amount and a Maximum Dollar Limit of Liability for certain coverages are also set forth in Attachment One. Copies of the policy forms should be read. They are available from the office which issued this report. This report (and any supplements or amendments hereto) is issued solely for the purpose of facilitating the issuance of a policy of title insurance and no liability is assumed hereby. If it is desired that liability be assumed prior to the issuance of a policy of title insurance, a Binder or Commitment should be requested. The policy(ies) of title insurance to be issued hereunder will be policy(ies) of Chicago Title Insurance Company, a Florida corporation. Please read the exceptions shown or referred to herein and the exceptions and exclusions set forth in Attachment One of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered. It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects and encumbrances affecting title to the land. Countersigned By: Authorized Officer or Agent Cl TA Preliminary Report Form -Modified (Adopted: 11.17.2006) Chicago Title Insurance Company By: President Attest: Secretary Printed: 05.02. 18 @ 11 : 58 AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 Visit Us on our Website: www.ctic.com CHICAGO TITLE COMPANY ATTACHMENT 4 ISSUING OFFICE: 2365 Northside Drive, Suite 600, San Diego, CA 92108 FOR SETTLEMENT INQUIRIES, CONTACT: Matthew Castriotta • FAX PRELIMINARY REPORT Title Officer: Patty Meredith Email: patty.meredith@ctt.com Phone No.: (619)521-3449 Fax No.: (619)209-3494 Title No.: 73718004139-PM PROPERTY ADDRESS(ES): 3648 Carlsbad Boulevard, Carlsbad, CA EFFECTIVE DATE: April 26, 2018 at 07:30 AM Customer: Matthew Castriotta Email: Matthew@mynmark.com Phone No.: Fax No.: Ref. No.: The form of policy or policies of title insurance contemplated by this report is: AL TA Homeowner's Policy of Title Insurance 2013 AL TA Loan Policy 2006 1. The estate or interest in the Land hereinafter described or referred to covered by this Report is: A Fee as to Parcel(s) 1 Easement(s) more fully described below as to Parcel(s) 2 2. Title to said estate or interest at the date hereof is vested in: Michael Jason Ianni, and Shauna L. Ianni, as Trustees of The Ianni Living Trust dated September 15, 2011 Subject to Item No. 11 3. The Land referred to in this Report is described as follows: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 2 Printed: 05.02.18@11:SBAM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 For APN/Parcel ID(s): 204-232-12-00 PARCEL 1: EXHIBIT "A" Legal Description ATTACHMENT 4 LOT "P" IN BLOCK 2 OF PALISADES HEIGHTS, IN THE COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO THE MAP THEREOF NO. 1777, FILED IN THE OFFICE OF THE RECORDER OF SAID SAN DIEGO COUNTY, JANUARY 11, 1924. PARCEL 2: A RIGHT OF WAY FOR ROAD PURPOSES OVER AND ACROSS THE NORTHEASTERLY 15.0 FEET OF LOTS "Q" AND "R" IN BLOCK 2 OF PALISADES HEIGHTS, IN THE CITY OF SAN DIEGO, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO THE MAP THEREOF NO.1777, FILED IN THE OFFICE OF THE RECORDER OF SAID SAN DIEGO COUNTY, JANUARY 11, 1924. SAID RIGHT OF WAY IS FOR THE BENEFIT OF AND APPURTENANT TO PARCEL 1, HEREINDESCRIBED, AND SHALL INSURE TO THE BENEFIT OF AND MAY BE USED BY ALL PERSONS WHO MAY HEREAFTER BECOME THE OWNERS OF SAID APPURTENANT PROPERTY OR ANY PARTS OR PORTIONS THEREOF .. CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 3 Printed: 05.02.18@11:58AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 C 0 ATTACHMENT 4 Title No.: 73718004139-PM AT THE DATE HEREOF, EXCEPTIONS TO COVERAGE IN ADDITION TO THE PRINTED EXCEPTIONS AND EXCLUSIONS IN SAID POLICY FORM WOULD BE AS FOLLOWS: 1. Property taxes, which are a lien not yet due and payable, including any assessments collected with taxes to be levied for the fiscal year 2018-2019. 2. Property taxes, including any personal property taxes and any assessments collected with taxes, are paid. For proration purposes the amounts were: Tax Identification No.: Fiscal Year: 1st Installment: 2nd Installment: Exemption: Code Area: 204-232-12-00 2017-2018 $9,949.00 $9,949.00 $0.00 09000 3. Supplemental taxes, including any personal property taxes and any assessments collected with taxes, assessed pursuant to the provisions of Chapter 3.5 (commencing with Section 75) of the Revenue and Taxation Code of the State of California, are as follows: Tax Identification No.: Fiscal Year: 1st Installment: 2nd Installment: Code Area.: 204-232-12-00 2017-2018 $4,380.36, paid $4,380.36, paid 09000 4. The lien of supplemental or escaped assessments of property taxes, if any, made pursuant to the provisions of Chapter 3.5 (commencing with Section 75) or Part 2, Chapter 3, Articles 3 and 4, respectively, of the Revenue and Taxation Code of the State of California as a result of the transfer of title to the vestee named in Schedule A or as a result of changes in ownership or new construction occurring prior to Date of Policy. 5. Easement(s) or right(s) of way for the purpose(s) shown below and rights incidental thereto, as granted and/or reserved in various deeds of record: Purpose: Affects: Ingress and egress, pipelines, drainage and/or public utilities and incidental purposes thereto over, under, along and across the easement parcel(s) herein described. Parcel 2 6. The Following Recital Contained in Deed from Laura G. Bates, to Wit, "Subject to an Easement Granted the San Diego Consolidated Gas and Electric Company, June 22, 1923". Said Easement is not a Matter of record. Recorded: in Book 264, Page 182 of Official Records 7. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: Purpose: Recording Date: Recording No.: Affects: San Diego Gas and Electric Company public utilities November 21, 1950 in Book 3870, Page 105, of Official Records a portion of said land as more particularly described in said document Cl TA Preliminary Report Form -Modified (Adopted: 11.17.2006) Printed 05.02.18@ 11:58 AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 4 EXCEPTIONS (continued) ATTACHMENT 4 Title No.: 73718004139-PM 8. Easement(s) for the purpose(s) shown below and rights incidental thereto as set forth in a document: Purpose: Recording Date: Recording No.: Affects: road and incidental purposes July 7, 1952 in Book 4516, Page 314, of Official Records a portion of said land as more particularly described in said document Said easement has been granted and/or reserved in various instruments of record. 9. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document: Granted to: Purpose: Recording Date: Recording No.: Affects: San Diego Gas and Electric Company public utilities August 25, 1982 1982-263033, of Official Records a portion of said land as more particularly described in said document 10. A deed of trust to secure an indebtedness in the amount shown below, Amount: Dated: Trustor/Grantor: Trustee: Beneficiary: Loan No.: Recording Date: Recording No.: $1,496,000.00 June 27, 2017 Michael Jason Ianni and Shauna L Ianni as trustees of Ianni Living Trust dated 09/15/2011 Chicago Title Company Mortgage Electronic Registration Systems, Inc. (MERS), solely as nominee for Banner Bank 18037584 June 29, 2017 2017-0296550, of Official Records NOTE: This loan appears to be registered with Mortgage Electronic Registration Systems, Inc., (MERS). The name, address and telephone number for loan servicing should be obtained from the MERS website: www.mers-servicerid.org or by calling, 1-888-679-MERS (1-888-679-6377), and referring to the Mortgage Identification Number (MIN) 1001679-0000968266-5. 11. Any invalidity or defect in the title of the vestees in the event that the trust referred to herein is invalid or fails to grant sufficient powers to the trustee(s) or in the event there is a lack of compliance with the terms and provisions of the trust instrument. If title is to be insured in the trustee(s) of a trust, (or if their act is to be insured}, this Company will require a Trust Certification pursuant to California Probate Code Section 18100.5. The Company reserves the right to add additional items or make further requirements after review of the requested documentation. CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 5 Printed: 05.02.18@11:SBAM CA-CT-FWO0-02180.055820-SPS-1-18-73718004139 C ATTACHMENT 4 Title No.: 73718004139-PM EXCEPTIONS ( continued) The Company will require a current Trust Certification, pursuant to California Probate Code Section 18100.5, confirming the following facts and containing the following information, with respect to the hereinafter named Trust(s): Name of Trust(s): The Ianni Living Trust 1. Date of execution and continued existence of the Trust; 2. Identity of the Settlor(s)/Trustor(s) and the currently acting Trustee(s); 3. Powers of the Trustee(s); 4. Whether the Trust is revocable or not and, if revocable, who holds the power to revoke the Trust; 5. If there are multiple trustees, the signature authority of the Trustees, including how many of the trustees are required to exercise powers of the Trust; 6. The Trust Identification Number [usually a Social Security Number or an Employer Identification Number]; 7. The manner in which title to Trust assets should be held; 8. The legal description of any interest in real property held in the trust; and 9. The Certificate of Trust must contain a statement that the trust has not been revoked, modified, or amended so as to cause the representations to be incorrect and that it is being signed by all current Trustee(s) in the form of an acknowledged declaration. Note: If an Affidavit of Death of a Trustee or Co-Trustee was or will be recorded, the signing successor or Surviving Trustee(s) must have the right to exercise the powers of the Trust. The Company reserves the right to add additional items or make further requirements after receipt of the Trust Certification. 12. Any rights, interests or claims, which are not shown by the public records but which could be ascertained by an inspection of the Land or which may be asserted by persons in possession thereof. 13. In order to complete this report, the Company requires a Statement of Information to be completed by the following party(ies), Seller(s): Michael Jason Ianni and Shauna L. Ianni The Company reserves the right to add additional items or make further requirements after review of the requested Statement of Information. NOTE: The Statement of Information is necessary to complete the search and examination of title under this order. Any title search includes matters that are indexed by name only, and having a completed Statement of Information assists the Company in the elimination of certain matters which appear to involve the parties but in fact affect another party with the same or similar name. Be assured that the Statement of Information is essential and will be kept strictly confidential to this file. CL TA Preliminary Report Fom1 -Modified (Adopted: 11.17.2006) 6 Printed: 05.02.18@ 11:58 AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 C EXCEPTIONS ( continued) ATTACHMENT 4 Title No. 73718004139-PM 14. In order to complete this report, the Company requires a Statement of Information to be completed by the following party(ies), Party(ies): Buyer(s) The Company reserves the right to add additional items or make further requirements after review of the requested Statement of Information. NOTE: The Statement of Information is necessary to complete the search and examination of title under this order. Any title search includes matters that are indexed by name only, and having a completed Statement of Information assists the Company in the elimination of certain matters which appear to involve the parties but in fact affect another party with the same or similar name. Be assured that the Statement of Information is essential and will be kept strictly confidential to this file. END OF EXCEPTIONS CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 7 Printed: 05.02.18@ 11 :58 AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 Note 1. Note 2. Note 3. Note 4. Note 5. C 0 ATTACHMENT 4 Title No.: 73718004139-PM NOTES Notice: Please be aware that due to the conflict between federal and state laws concerning the cultivation, distribution, manufacture or sale of marijuana, the Company is not able to close or insure any transaction involving Land that is associated with these activities. If a county recorder, title insurance company, escrow company, real estate agent or association provides a copy of the declaration, governing document or deed to any person, California law requires that the document provided shall include a statement regarding any unlawful restrictions. Said statement is to be in at least 14-point bold faced typed and may be stamped on the first page of any document provided or included as a cover page attached to the requested document. Should a party to this transaction request a copy of any document reported herein that fits this category, the statement is to be included in the manner described. Any documents being executed in conjunction with this transaction must be signed in the presence of an authorized Company employee, an authorized employee of an agent, an authorized employee of the insured lender, or by using Bancserv or other approved third-party service. If the above requirements cannot be met, please call the company at the number provided in this report. Your application for title insurance was placed by reference to only a street address or tax identification number. Based on our records, we believe that the legal description in this report covers the parcel(s) of Land that you requested. If the legal description is incorrect, the seller/borrower must notify the Company and/or the settlement company in order to prevent errors and to be certain that the correct parcel(s) of land will appear on any documents to be recorded in connection with this transaction and on the policy of title insurance. Note: The only conveyances(s) affecting said Land, which recorded within 24 months of the date of this report, are as follows: Grantor: Grantee: Recording Date: Recording No.: Kovens Cherry Carlsbad LLC, A Nevada Limited Liability Company Michael Jason Ianni, and Shauna L. Ianni, as Trustees of The Ianni Living Trust dated September 15, 2011 June 29, 2017 2017-0296549, of Official Records Note 6. A Preliminary Change of Ownership form is required upon a change in ownership of the Land. Section 480 of the Revenue and Taxation Code of the State of California requires that a grantee of real property complete a Preliminary Change of Ownership statement, which is to be filed at the time that a grant deed is recorded. In the event that the statement is not completed and presented at the time of the recording of the deed, the County Recorder will assess the grantee an additional charge to record the deed. In addition to the additional charge at the time of recording, the County Assessor may assess additional fees and penalties for failure to file the Ownership Statement within the required time. Note 7. Note: The Company is not aware of any matters which would cause it to decline to attach CLTA Endorsement Form 116 indicating that there is located on said Land a multiple family residence, known as 3648 Carlsbad Boulevard, Carlsbad, CA, to an Extended Coverage Loan Policy. Note 8. Note: None of the items shown in this report will cause the Company to decline to attach CL TA Endorsement Form 100 to an Extended Coverage Loan Policy, when issued. Note 9. If the Land is located within the area affected by a Geographic Targeting Order issued by FinCEN (California counties of Los Angeles, San Diego, San Francisco, Santa Clara and San Mateo), the Company must be supplied with a completed ALTA Information Collection Form ("ICF"). Note 10. Pursuant to Government Code Section 27388.1, as amended and effective as of 1-1-2018, a Documentary Transfer Tax (OTT) Affidavit may be required to be completed and submitted with each document when OTT is being paid or when an exemption is being claimed from paying the tax. If a governmental agency is a party to the document, the form will not be required. OTT Affidavits may be available at a Tax Assessor-County Clerk-Recorder. CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 8 Printed: 05.02.18@11:SBAM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 NOTES ( continued) END OF NOTES CL TA Preliminary Report Form -Modified (Adopted: 11.17.2006) 9 ATTACHMENT 4 Title No.: 73718004139-PM Printed: 05.02.18@ 11:58 AM CA-CT-FWD0-02180.055820-SPS-1-18-73718004139 ATTACHMENT 4 ::1w1 RE SAFE"' ' Inquire before you wire! WIRE FRAUD ALERT This Notice is not intended to provide legal or professional advice. If you have any questions, please consult with a lawyer. All parties to a real estate transaction are targets for wire fraud and many have lost hundreds of thousands of dollars because they simply relied on the wire instructions received via email, without further verification. If funds are to be wired in conjunction with this real estate transaction, we strongly recommend verbal verification of wire instructions through a known, trusted phone number prior to sending funds. In addition, the following non-exclusive self-protection strategies are recommended to minimize exposure to possible wire fraud. • NEVER RELY on emails purporting to change wire instructions. Parties to a transaction rarely change wire instructions in the course of a transaction. • ALWAYS VERIFY wire instructions, specifically the ABA routing number and account number, by calling the party who sent the instructions to you. DO NOT use the phone number provided in the email containing the instructions, use phone numbers you have called before or can otherwise verify. Obtain the number of relevant parties to the transaction as soon as an escrow account is opened. DO NOT send an email to verify as the email address may be incorrect or the email may be intercepted by the fraudster. • USE COMPLEX EMAIL PASSWORDS that employ a combination of mixed case, numbers, and symbols. Make your passwords greater than eight (8) characters. Also, change your password often and do NOT reuse the same password for other online accounts. • USE MULTI-FACTOR AUTHENTICATION for email accounts. Your email provider or IT staff may have specific instructions on how to implement this feature. For more information on wire-fraud scams or to report an incident, please refer to the following links: Federal Bureau of Investigation: http://www. fbi. gov Internet Crime Complain Center: http://www.ic3.gov Wire Fraud Alert Original Effective Date: 5/11/2017 Current Version Date: 5/11/2017 73718004139bc-WIRE0016 (OSI Rev. 12/07/17) TM and© Fidelity National Financial, Inc. and/or an affiliate. All rights reserved FIDELITY NATIONAL FINANCIAL PRIVACY NOTICE Revised May 1, 2018 ATTACHMENT 4 Fidelity National Financial, Inc. and its majority-owned subsidiary companies (collectively, "FNF", "our," or "we") respect and are committed to protecting your privacy. This Privacy Notice explains how we collect, use, and protect personal information, when and to whom we disclose such information, and the choices you have about the use and disclosure of that information. Types of Information Collected We may collect two types of information from you: Personal Information and Browsing Information. Personal Information. FNF may collect the following categories of Personal Information: contact information (e.g., name, address, phone number, email address); demographic information (e.g., date of birth, gender, marital status); identity information (e.g. Social Security Number, driver's license, passport, or other government ID number); financial account information (e.g. loan or bank account information); and other personal information necessary to provide products or services to you. Browsing Information. FNF may automatically collect the following types of Browsing Information when you access an FNF website, online service, or application (each an "FNF Website") from your Internet browser, computer, and/or mobile device: Internet Protocol (IP) address and operating system; browser version, language, and type; domain name system requests; and browsing history on the FNF Website, such as date and time of your visit to the FNF Website and visits to the pages within the FNF Website. How Personal Information is Collected We may collect Personal Information about you from: information we receive from you on applications or other forms; information about your transactions with FNF, our affiliates, or others; and information we receive from consumer reporting agencies and/or governmental entities, either directly from these entities or through others. How Browsing Information is Collected If you visit or use an FNF Website, Browsing Information may be collected during your visit. Like most websites, our servers automatically log each visitor to the FNF Website and may collect the Browsing Information described above. We use Browsing Information for system administration, troubleshooting, fraud investigation, and to improve our websites. Browsing Information generally does not reveal anything personal about you, though if you have created a user account for an FNF Website and are logged into that account, the FNF Website may be able to link certain browsing activity to your user account. Other Online Specifics Cookies. When you visit an FNF Website, a "cookie" may be sent to your computer. A cookie is a small piece of data that is sent to your Internet browser from a web server and stored on your computer's hard drive. Information gathered using cookies helps us improve your user experience. For example, a cookie can help the website load properly or can customize the display page based on your browser type and user preferences. You can choose whether or not to accept cookies by changing your Internet browser settings. Be aware that doing so may impair or limit some functionality of the FNF Website. Web Beacons. We use web beacons to determine when and how many times a page has been viewed. This information is used to improve our websites. Do Not Track. Currently our FNF Websites do not respond to "Do Not Track" features enabled through your browser. Links to Other Sites. FNF Websites may contain links to other websites. FNF is not responsible for the privacy practices or the content of any of those other websites. We advise you to read the privacy policy of every website you visit. Privacy Statement SCA0002565_CTLA.doc I Updated: 01.29.18 Printed: 05.02.18@11:SBAMbye -73718004139 ATTACHMENT 4 Use of Personal Information FNF uses Personal Information for three main purposes: To provide products and services to you or in connection with a transaction involving you. To improve our products and services. To communicate with you about our, our affiliates', and third parties' products and services, jointly or independently. When Information Is Disclosed We may make disclosures of your Personal Information and Browsing Information in the following circumstances: to enable us to detect or prevent criminal activity, fraud, material misrepresentation, or nondisclosure; to nonaffiliated service providers who provide or perform services or functions on our behalf and who agree to use the information only to provide such services or functions; to nonaffiliated third party service providers with whom we perform joint marketing, pursuant to an agreement with them to jointly market financial products or services to you; to law enforcement or authorities in connection with an investigation, or in response to a subpoena or court order; or in the good-faith belief that such disclosure is necessary to comply with legal process or applicable laws, or to protect the rights, property, or safety of FNF, its customers, or the public. The law does not require your prior authorization and does not allow you to restrict the disclosures described above. Additionally, we may disclose your information to third parties for whom you have given us authorization or consent to make such disclosure. We do not otherwise share your Personal Information or Browsing Information with nonaffiliated third parties, except as required or permitted by law. We reserve the right to transfer your Personal Information, Browsing Information, and any other information, in connection with the sale or other disposition of all or part of the FNF business and/or assets, or in the event of bankruptcy, reorganization, insolvency, receivership, or an assignment for the benefit of creditors. By submitting Personal Information and/or Browsing Information to FNF, you expressly agree and consent to the use and/or transfer of the foregoing information in connection with any of the above described proceedings. Please see "Choices With Your Information" to learn the disclosures you can restrict. Security of Your Information We maintain physical, electronic, and procedural safeguards to guard your Personal Information. We limit access to nonpublic personal information about you to employees who need to know that information to do their job. When we provide Personal Information to others as discussed in this Privacy Notice, we expect that they process such information in compliance with our Privacy Notice and in compliance with applicable privacy laws. Choices With Your Information If you do not want FNF to share your information with our affiliates to directly market to you, you may send an "opt out" request by email, phone, or physical mail as directed at the end of this Privacy Notice. We do not share your Personal Information with nonaffiliates for their use to direct market to you. Whether you submit Personal Information or Browsing Information to FNF is entirely up to you. If you decide not to submit Personal Information or Browsing Information, FNF may not be able to provide certain services or products to you. For California Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties, except as permitted by California law. For Nevada Residents: You may be placed on our internal Do Not Call List by calling (888) 934-3354 or by contacting us via the information set forth at the end of this Privacy Notice. Nevada law requires that we also provide you with the following contact information: Bureau of Consumer Protection, Office of the Nevada Attorney General, 555 E. Washington St., Suite 3900, Las Vegas, NV 89101; Phone number: (702) 486-3132; email: BCPIN FO@ag. state. nv. us. For Oregon Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties for marketing purposes, except after you have been informed by us of such sharing and had an opportunity to indicate that you do not want a disclosure made for marketing purposes. Privacy Statement SCA0002565_CTLA.doc / Updated: 01.29.18 Printed 05.02.18@ 11 58 AM bye -73718004139 ATTACHMENT 4 For Vermont Residents: We will not disclose information about you creditworthiness to our affiliates and will not disclose your personal information, financial information, credit report, or health information to nonaffiliated third parties to market to you, other than as permitted by Vermont law, unless you authorize us to make those disclosures. Information From Children The FNF Websites are meant for adults and are not intended or designed to attract persons under the age of eighteen (18). We do not collect Personal Information from any person that we know to be under the age of thirteen (13) without permission from a parent or guardian. International Users FNF's headquarters is located within the United States. If you reside outside the United States and choose to provide Personal Information or Browsing Information to us, please note that we may transfer that information outside of your country of residence for any of the purposes described in this Privacy Notice. By providing FNF with your Personal Information and/or Browsing Information, you consent to our collection, transfer, and use of such information in accordance with this Privacy Notice. FNF Website Services for Mortgage Loans Certain FNF companies provide services to mortgage loan servicers, including hosting websites that collect customer information on behalf of mortgage loan servicers (the "Service Websites"). The Service Websites may contain links to both this Privacy Notice and the mortgage loan servicer or lender's privacy notice. The sections of this Privacy Notice titled When Information is Disclosed, Choices with Your Information, and Accessing and Correcting Information do not apply to the Service Websites. The mortgage loan servicer or lender's privacy notice governs use, disclosure, and access to your Personal Information. FNF does not share Personal Information collected through the Service Websites, except (1) as required or authorized by contract with the mortgage loan servicer or lender, or (2) as required by law or in the good-faith belief that such disclosure is necessary to comply with a legal process or applicable law, to enforce this Privacy Notice, or to protect the rights, property, or safety of FNF or the public. Your Consent To This Privacy Notice; Notice Changes By submitting Personal Information and/or Browsing Information to FNF, you consent to the collection and use of the information in accordance with this Privacy Notice. We may change this Privacy Notice at any time. The revised Privacy Notice, showing the new revision date, will be posted on the FNF Website. Each time you provide information to us following any amendment of this Privacy Notice, your provision of information to us will signify your assent to and acceptance of the terms of the revised Privacy Notice for all previously collected information and information collected from you in the future. We may use comments, information or feedback that you submit to us in any manner that we may choose without notice or compensation to you. Accessing and Correcting Information; Contact Us If you have questions, would like to access or correct your Personal Information, or want to opt-out of information sharing for affiliate marketing, send your requests via email to privacy@fnf.com, by phone to (888) 934-3354, or by mail to: Privacy Statement SCA0002565_CTLA.doc / Updated: 01.29.18 Fidelity National Financial, Inc. 601 Riverside Avenue, Jacksonville, Florida 32204 Attn: Chief Privacy Officer Printed: 05.02.18 @ 11 :58 AM bye -73718004139 0 ATTACHMENT ONE CALIFORNIA LAND TITLE ASSOCIATION STANDARD COVERAGE POLICY-1990 EXCLUSIONS FROM COVERAGE ATTACHMENT 4 The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance or governmental regulation (including but not limited to building or zoning laws, ordinances, or regulations) restricting, regulating, prohibiting or relating (i) the occupancy, use, or enjoyment of the land; (ii) the character, dimensions or location of any improvement now or hereafter erected on the land; (iii) a separation in ownership or a change in the dimensions or area of the land or any parcel of which the land is or was a part; or (iv) environmental protection, or the effect of any violation of these laws, ordinances or governmental regulations, except to the ex1ent that a notice of the enforcement thereof or a notice of a defect, lien, or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any governmental police power not excluded by (a) above, except to the ex1ent that a notice of the exercise thereof or notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Rights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) whether or not recorded in the public records at Date of Policy, but created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting in no loss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy; or (e) resulting in loss or damage which would not have been sustained if the insured claimant had paid value for the insured mortgage or for the estate or interest insured by this policy. 4. Unenforceability of the lien of the insured mortgage because of the inability or failure of the insured at Date of Policy, or the inability or failure of any subsequent owner of the indebtedness, to comply with the applicable doing business laws of the state in which the land is situated. 5. Invalidity or unenforceability of the lien of the insured mortgage, or claim thereof, which arises out of the transaction evidenced by the insured mortgage and is based upon usury or any consumer credit protection or truth in lending law. 6. Any claim, which arises out of the transaction vesting in the insured the estate or interest insured by this policy or the transaction creating the interest of the insured lender, by reason of the operation of federal bankruptcy, state insolvency or similar creditors' rights laws. EXCEPTIONS FROM COVERAGE -SCHEDULE B, PART I This policy does not insure against loss or damage (and the Company will not pay costs, attorneys' fees or expenses) which arise by reason of: 1. Taxes or assessments which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the public records. Proceedings by a public agency which may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the public records. 2. Any facts, rights, interests, or claims which are not shown by the public records but which could be ascertained by an inspection of the land or which may be asserted by persons in possession thereof. 3. Easements, liens or encumbrances, or claims thereof, not shown by the public records. 4. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other facts which a correct survey would disclose, and which are not shown by the public records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b) or (c) are shown by the public records. 6. Any lien or right to a lien for services, labor or material not shown by the public records. Attachment One (05/06/16) ATTACHMENT 4 ATTACHMENT ONE (CONTINUED) CLTA HOMEOWNER'$ POLICY OF TITLE INSURANCE (12-02-13) ALT A HOMEOWNER'$ POLICY OF TITLE INSURANCE EXCLUSIONS In addition to the Exceptions in Schedule B, You are not insured against loss, costs, attorneys' fees, and expenses resulting from: 1. Governmental police power, and the existence or violation of those portions of any law or government regulation concerning: a. building; b. zoning; c. land use; d. improvements on the Land; e. land division; and f. environmental protection. This Exclusion does not limit the coverage described in Covered Risk 8.a., 14, 15, 16, 18, 19, 20, 23 or 27. 2. The failure of Your existing structures, or any part of them, to be constructed in accordance with applicable building codes. This Exclusion does not limit the coverage described in Covered Risk 14 or 15. 3. The right to take the Land by condemning it. This Exclusion does not limit the coverage described in Covered Risk 17. 4. Risks: a. that are created, allowed, or agreed to by You, whether or not they are recorded in the Public Records; b. that are Known to You at the Policy Date, but not to Us, unless they are recorded in the Public Records at the Policy Date; c. that result in no loss to You; or d. that first occur after the Policy Date -this does not limit the coverage described in Covered Risk 7, 8.e., 25, 26, 27 or 28. 5. Failure to pay value for Your Title. 6. Lack of a right: a. to any land outside the area specifically described and referred to in paragraph 3 of Schedule A; and b. in streets, alleys, or waterways that touch the Land. This Exclusion does not limit the coverage described in Covered Risk 11 or 21. 7. The transfer of the Title to You is invalid as a preferential transfer or as a fraudulent transfer or conveyance under federal bankruptcy, state insolvency, or similar creditors' rights laws. 8. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake or subsidence. 9. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances. LIMITATIONS ON COVERED RISKS Your insurance for the following Covered Risks is limited on the Owner's Coverage Statement as follows: For Covered Risk 16, 18, 19 and 21, Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A. The deductible amounts and maximum dollar limits shown on Schedule A are as follows: Covered Risk 16: Covered Risk 18: Covered Risk 19: Covered Risk 21: Your Deductible Amount 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less) 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less) 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less) 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less) Our Maximum Dollar Limit of Liability $ 10,000.00 $ 25,000.00 $ 25,000.00 $ 5,000.00 Attachment One (05/06/16) ATTACHMENT ONE (CONTINUED) 2006 ALT A LOAN POLICY (06-17-06) EXCLUSIONS FROM COVERAGE ATTACHMENT 4 The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, costs, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1 (a) does not modify or limit the coverage provided under Covered Risk 5. (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant: (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, 13, or 14); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Insured Mortgage. 4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applicable doing-business laws of the state where the Land is situated. 5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evidenced by the Insured Mortgage and is based upon usury or any consumer credit protection or truth-in-lending law. 6. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that the transaction creating the lien of the Insured Mortgage, is (a) a fraudulent conveyance or fraudulent transfer, or (b) a preferential transfer for any reason not stated in Covered Risk 13(b) of this policy. 7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the Insured Mortgage in the Public Records. This Exclusion does not modify or limit the coverage provided under Covered Risk 11(b). The above policy form may be issued to afford either Standard Coverage or Ex1ended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: EXCEPTIONS FROM COVERAGE [Except as provided in Schedule B -Part II,[ t[or T]his policy does not insure against loss or damage, and the Company will not pay costs, attorneys' fees, or expenses that arise by reason of: [PARTI [The above policy form may be issued to afford either Standard Coverage or Ex1ended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that are not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material not shown by the Public Records.] PARTII In addition to the matters set forth in Part I of this Schedule, the Title is subject to the following matters, and the Company insures against loss or damage sustained in the event that they are not subordinate to the lien of the Insured Mortgage:] Attachment One (05/06/16) ATTACHMENT 4 ATTACHMENT ONE (CONTINUED) 2006 ALTA OWNER'S POLICY (06-17-06) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, costs, attorneys' fees, or expenses that arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1 (a) does not modify or limit the coverage provided under Covered Risk 5. (b) Any governmental police power. This Exclusion 1 (b) does not modify or limit the coverage provided under Covered Risk 6. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 9 and 10); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Title. 4. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that the transaction vesting the Title as shown in Schedule A, is (a) a fraudulent conveyance or fraudulent transfer; or (b) a preferential transfer for any reason not stated in Covered Risk 9 of this policy. 5. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the deed or other instrument of transfer in the Public Records that vests Title as shown in Schedule A. The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: EXCEPTIONS FROM COVERAGE This policy does not insure against loss or damage, and the Company will not pay costs, attorneys' fees, or expenses that arise by reason of: [The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage: 1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 2. Any facts, rights, interests, or claims that are not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records. 6. Any lien or right to a lien for services, labor or material not shown by the Public Records.] 7. [Variable exceptions such as taxes, easements, CC&R's, etc., shown here.] Attachment One (05/06/16) C ATTACHMENT 4 ATTACHMENT ONE (CONTINUED) ALT A EXPANDED COVERAGE RESIDENTIAL LOAN POLICY -ASSESSMENTS PRIORITY (04-02-15) EXCLUSIONS FROM COVERAGE The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to (i) the occupancy, use, or enjoyment of the Land; (ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or (iv) environmental protection; or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1 (a) does not modify or limit the coverage provided under Covered Risk 5, 6, 13(c), 13(d), 14 or 16. (b) Any governmental police power. This Exclusion 1 (b) does not modify or limit the coverage provided under Covered Risk 5, 6, 13(c), 13(d), 14 or 16. 2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8. 3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, 16, 17, 18, 19, 20, 21, 22, 23, 24, 27 or 28); or (e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Insured Mortgage. 4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applicable doing-business laws of the state where the Land is situated. 5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evidenced by the Insured Mortgage and is based upon usury, or any consumer credit protection or truth-in-lending law. This Exclusion does not modify or limit the coverage provided in Covered Risk 26. 6. Any claim of invalidity, unenforceability or lack of priority of the lien of the Insured Mortgage as to Advances or modifications made after the Insured has Knowledge that the vestee shown in Schedule A is no longer the owner of the estate or interest covered by this policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11. 7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching subsequent to Date of Policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11 (b) or 25. 8. The failure of the residential structure, or any portion of it, to have been constructed before, on or after Date of Policy in accordance with applicable building codes. This Exclusion does not modify or limit the coverage provided in Covered Risk 5 or 6. 9. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that the transaction creating the lien of the Insured Mortgage, is (a) a fraudulent conveyance or fraudulent transfer, or (b) a preferential transfer for any reason not stated in Covered Risk 27(b) of this policy. 10. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence. 11. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances. Attachment One (05/06/16) ATTACHMENT 4 Notice of Available Discounts Pursuant to Section 2355.3 in Title 10 of the California Code of Regulations Fidelity National Financial, Inc. and its subsidiaries ("FNF") must deliver a notice of each discount available under our current rate filing along with the delivery of escrow instructions, a preliminary report or commitment. Please be aware that the provision of this notice does not constitute a waiver of the consumer's right to be charged the filed rate. As such, your transaction may not qualify for the below discounts. You are encouraged to discuss the applicability of one or more of the below discounts with a Company representative. These discounts are generally described below; consult the rate manual for a full description of the terms, conditions and requirements for such discount. These discounts only apply to transactions involving services rendered by the FNF Family of Companies. This notice only applies to transactions involving property improved with a one-to-four family residential dwelling. Not all discounts are offered by every FNF Company. The discount will only be applicable to the FNF Company as indicated by the named discount. FNF Underwritten Title Companies CTC -Chicago Title Company Available Discounts Underwritten by FNF Underwriters CTIC -Chicago Title Insurance Company CREDIT FOR PRELIMINARY TITLE REPORTS AND/OR COMMITMENTS ON SUBSEQUENT POLICIES (CTIC) Where no major change in the title has occurred since the issuance of the original report or commitment, the order may be reopened within 12 to 36 months and all or a portion of the charge previously paid for the report or commitment may be credited on a subsequent policy charge. FEE REDUCTION SETTLEMENT PROGRAM (CTC, CTIC) Eligible customers shall receive a $20.00 reduction in their title and/or escrow fees charged by the Company for each eligible transaction in accordance with the terms of the Final Judgments entered in The People of the State of California et al. v. Fidelity National Title Insurance Company et al., Sacramento Superior Court Case No. 99AS02793, and related cases. DISASTER LOANS (CTIC) The charge for a Lender's Policy (Standard or Extended coverage) covering the financing or refinancing by an owner of record, within 24 months of the date of a declaration of a disaster area by the government of the United States or the State of California on any land located in said area, which was partially or totally destroyed in the disaster, will be 50% of the appropriate title insurance rate. CHURCHES OR CHARITABLE NON-PROFIT ORGANIZATIONS (CTIC) On properties used as a church or for charitable purposes within the scope of the normal activities of such entities, provided said charge is normally the church's obligation the charge for an owner's policy shall be 50% to 70% of the appropriate title insurance rate, depending on the type of coverage selected. The charge for a lender's policy shall be 32% to 50% of the appropriate title insurance rate, depending on the type of coverage selected. Notice of Available Discounts SCA0002565_CTLA.doc / Updated: 01.29.18 Printed: 05.02.18@ 11:58 AM bye -73718004139 Cl~ H • !l !f i .. OD ~"' &3 12§: !l •= n ~! h ... "I. !l Ji ,, ,i I .u !1;,f s J ! if',: fit gl~ ·11 ii J! •g II "' !!.= f _a I !1 H l ~:. ~ ~l 0 ... I! ., I .. !lo. l :• lj i i¾Q, i~ 11 i H 09 IH'-~~~ I stt1°~-Jf 3 ~ ~J I @ I I @ I 'L l l GARFIELD ST • t7 ...... # • ' s,~•,,•,r -#U•.t:J"tl ,t 0 j. f• S. ""',.. ·• •l.JZ HJ:J UU ,., .. fDH U•• WU :11, '° r- ~ ,. ~ I© !:: PAAI UI UI ll ~ I W 0 ~0a W ~ 14 13 >-0 @ G) 0 0 -~ D ~ -r.::,. 1 c{ 1"7-'iHi~~'l::,,.~~lll!:~-U A B C D E PM21475. ,., @ I ~ # .. ,, .. n UU ~ ~ , N,, " ~---~~ ---@ , BLK @) C ~ BLK G) 0 I ; • F ~ 18 M--------,~-'1.,.,.,ll:14,~"'2!~f F G ~ ~ (@)@ 19 1 :,~, ! (!} G) @ , BLK @H I0 2 @ ===,~TY l;j @) a @) , •• I '--....... --==-i • H I ' i @) @ I IQ W ,. 13 20 ,..,,. .,.,..., '.j ®21 ~ " ~ @ ~ ! J K -~-Q9 :r ,. r.,. ~ r.:,,. II Q. t.:\ <( ,... ,...,,~ K , .. ,, ► ,;.-PMl~t ' U \!!I \!!I ~,.. i (e) c( f ~22 I U .,.. u .,.. .. CC \ell W,Pf-R. o : ~ 9 --•• -4( ® Gi> @ ® ® ffi ...... "" -1 ./,,, PM i2449 Q: .. • ·: It Ii tlf 'I 11@1 ~ I ~L""' lit'.'\ I 1.:::1 I I .. 1 •• .. I ~ ' i5 ® @) @) I G ® 5 3 r 4 ti I ,. ,11 mitt~ 11:;:l ~ L .. , ! ; \ i t , 10•, 11• : • ":" , , EB L M N 1 0 P ~ ; ; ~ ~mo, ,. ~)",. M"'5, ~ ... .,. N 0 CARLSBAD 6o -.J:,... '!.~~~·Z--7:{_, ~#4 -6, a; i Cf:'; ,, 0 I~ ! ' z ' ,~ ~ .,~~ I<.:~ ~I; ~~11m~• ,~ H U! ~ 1:18 38 8 S ~ ~~ . <.lii I :i ~1 u ll~ • 1 ft 1 '°" ·i j .... N t:: st a! 1c1: aa a! au <Al•SD· 21U @1•CONOO e-CONOO LA~ .DOER BEACH DOC1177'°468747 DOC1lll3-0008807 (SEE StfT 2) (SEE 8tfT 2) 10'COID) MONROY Pl.ACE ooc,_ (SEESHT3) 2" CONDO 1"' COfCX) MELE I ANDREWBLAPOSADA NOi Hl.1. OOC197&-038053t DOC1-.o3t0521 (SEE 8HT 2) {SEE SHT 3) 11" COfO) (PEND) BAIICOCK ooc,_, S" CONDO 8" CONDO 12" CONDO K:,K',,IA,VII.I.AS MAPLE COURT JUNIPERATGARFELOMONROY Pl.ACE DOC1974-008IIOIIB DOC1181M11501S39 D0C2001--0242219 (SEE SHT 2) I 00C200f..1221"'53 (SEE SHT 3) 4" CONDO (SEE SHT 3) 13• CONJO CMTAMAR 9' CON>O VILLAS 0E LUZ DOC1174-00IJIIS101 & 1975-00IS9518 ~~ D0C2001'..()19732B ,.=:rr2) (SEE8HT3) r~~r,,936 l'&~~.:\', MAP 8695 -CARLSBAD TRACT NO 77-4 (LA POSADA) BOOK 204 PACE 2l SHT 1 Of" 3 t8EESHT2> MAP 1777 -PALISADES HEIGHTS REFILED MAP 1747 -PALISADES ROS 22534 0 ...... ~~ • ~ -:r.. • ~.'C.' -r--;s.. ;.,_ ,. ~ ""-' ,r;;;,._ __, ~ '"t ~j·u~ /, . ~ 1) DETAIL , .. (' -V,sl <"' (S) -v,, ~-~ ,:.~ V t 'o (,~J , .. DETAIL "A" CHICAGO TITLE COMPANY ORDER NO. 73718004139 05/02/2018 APN 204-232-12-00 Legend CJ PAR1 ~ PAR 2 [Iill] [Iill] Ease for Undisclosed Purpose recorded Bk264 Pg 182 OR -Item 6 (Unlocatable) Ease for Public Utilities recorded 11/21/1950 Bk3870 Pg105 OR -Item 7 (Centerline of Undisclosed Width Strip) Ease for Road recorded 07/07/1952 Bk4516 Pg314 OR -Item 8 Ease for Public Utilities recorded 08/25/1982 # 1982-263033 OR -Item 9 This map/plat is being furnished as an aid in locating the herein described Land in relation to adjoining streets, natural boundaries and other land, and is not a survey of the land depicted. Except to the extent a policy of title insurance is expressly modified by endorsement, if any, the Company does not insure dimensions, distances, location of easements, acreage or other matters shown thereon. ATTACHMENT 6 I dn L::.onsulf'ing, In&. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 www.ldnconsulting.net fax 760-689-4943 April 14, 2016 Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 Subject: Breakers View Beach House Residential Development Noise Assessment in the City of Carlsbad CA The firm of Ldn Consulting is pleased to submit the following interior noise impact analysis for the proposed Breakers View Beach House residential development in the City of Carlsbad. The purpose of the survey is to determine the estimated interior noise levels within the residential structures and recommend mitigation measures for compliance with the California Code of Regulations Title 24 and the City of Carlsbad guidelines and requirements for interior noise. project Location t pescci ptjon The project site is located at 3648 Carlsbad Boulevard, approximately 0.6 miles south of Carlsbad Village Drive and 0.6 miles west of the Interstate 5 (I-5) freeway in the City of Carlsbad, CA. The project vicinity can be seen in Figure 1 on the following page. The project proposes a 2 unit residential development. The project site configuration is provided in Figure 2 on Page 3. The main source for noise is from vehicular traffic from adjacent Carlsbad Boulevard. Acoustjcal Fundamentals Noise is defined as unwanted or annoying sound which interferes with or disrupts normal activities. Exposure to high noise levels has been demonstrated to cause hearing loss. The individual human response to environmental noise is based on the sensitivity of that individual, the type of noise that occurs and when the noise occurs. 4/14/16 1 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 Carlsbad 4/14/16 ATTACHMENT 6 Ldn Contlulllng, /ne,. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 Figure 1: Project Site Location \ Project Location -.. 2 t l f 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 4/14/16 ATTACHMENT 6 Ldn Conlfu/Hng, lne.. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 Figure 2: Project Site Configuration CARLSBAD BL VD 3 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATTACHMENT 6 Ldn~Hng, lne.. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 Sound is measured on a logarithmic scale consisting of sound pressure levels known as a decibel (dB). The sounds heard by humans typically do not consist of a single frequency but of a broadband of frequencies having different sound pressure levels. The method for evaluating all the frequencies of the sound is to apply an A-weighting to reflect how the human ear responds to the different sound levels at different frequencies. The A-weighted sound level adequately describes the instantaneous noise whereas the equivalent sound level depicted as Leq represents a steady sound level containing the same total acoustical energy as the actual fluctuating sound level over a given time interval. The Community Noise Equivalent Level (CNEL) is the 24 hour A-weighted average for sound, with corrections for evening and nighttime hours. The corrections require an addition of 5 decibels to sound levels in the evening hours between 7 p.m. and 10 p.m. and an addition of 10 decibels to sound levels at nighttime hours between 10 p.m. and 7 a.m. These additions are made to account for the increased sensitivity during the evening and nighttime hours when sound appears louder. CNEL values do not represent the actual sound level heard at any particular time, but rather represents the total sound exposure. Additionally, Sound Transmission Class (or STC) is an integer rating of how well airborne sound is attenuated by a building partition. STC is widely used to rate interior partitions, ceilings/floors, doors, windows and exterior wall configurations (see ASTM International Classification E413 and E90). The STC number is derived from tested sound attenuation values found at the 1/3 octave band frequencies. These transmission-loss {TL) values are then plotted and compared to a standard reference contour. Acoustical engineers fit these values to the appropriate TL Curve to determine a single STC value found at 500 Hertz. STC is roughly the decibel reduction in noise a partition can provide, abbreviated 'dB'. If an 85 dB sound on one side of a wall is reduced to 50 dB on the other side, that partition is said to have an STC of 35. This number does not apply across the range of frequencies because the STC value is derived from a curve-fit from the tested 1/3 octave band frequencies. Any partition will have less TL at lower frequencies. For example, a wall with an STC of 35 may provide over 40 dB of attenuation at 3000 Hz but only 15 dB of attenuation at 125 Hz. Exterior Noise standards The City of Carlsbad's Noise Element requires that all exterior sensitive areas shall limit noise exposure. For noise sensitive residential land uses, the City has adopted a policy which has 4/14/16 4 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATTACHMENT 6 Ldn L:ontluillng, lne.. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 established a "normally acceptable" exterior noise level goal of 60 dBA CNEL for the outdoor areas and an interior noise level of less than 45 dBA CNEL. For residential properties identified as requiring a noise study, a study shall be prepared by an acoustical professional. This study shall document the projected maximum exterior noise level and mitigate the projected exterior noise level to a maximum allowable noise level as identified in Noise Guideline Manual. Interior Nojse standards California's Title 24 Noise Standards In 1974, the California Commission on Housing and Community Development adopted noise insulation standards for multi-family residential buildings (Title 24, Part 2, California Code of Regulations or CCR). CCR Title 24 establishes standards, based on the U.S. Department of Housing and Urban Development (HUD) requirements, for interior room noise (attributable to outside noise sources). The regulations also specify that acoustical studies must be prepared whenever a multi-family residential or motel/hotel building or structure is proposed to be located near an existing or adopted freeway route, expressway, parkway, major street, thoroughfare, rail line, rapid transit line, or industrial noise source, and where such noise sources create an exterior CNEL (or Ldn) of 60 dBA or greater. Such acoustical analysis must demonstrate that the residence has been designed to limit intruding noise to an interior CNEL (or Ldn) of at least 45 dBA. Analysis procedures Exterior Noise Levels The primary source of noise impacts to the project site will be vehicular noise from adjacent Carlsbad Boulevard. The projected roadway noise levels from vehicular traffic were calculated using the methods in the Highway Noise Model published by the Federal Highway Administration (FHWA Highway Traffic Noise Prediction Model, FHWA·RD-77-108, December, 1978). The FHWA Model uses the traffic volume, vehicle mix, speed, and roadway geometry to compute the equivalent noise level. A spreadsheet calculation was used which computes equivalent noise levels for each of the time periods used in the calculation of CNEL. Weighting these equivalent noise levels and summing them gives the CNEL for the trafficprojections. 4/14/16 5 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATTACHMENT 6 Ldn Condu/Hng, lne. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 Mobile noise levels radiant in an almost oblique fashion from the source and drop off at a rate of 3 dBA for each doubling of distance under hard site conditions and at a rate of 4.5 dBA for soft site conditions. Hard site conditions consist of concrete, asphalt and hard pack dirt wh ile soft site conditions exist in areas having slight grade changes, landscaped areas and vegetation. The future traffic noise model also utilizes the vehicle mix referenced in the City's Noise Guideline Manual of 97.9% Autos, 1.8% Medium Trucks and 0.3% Heavy Trucks for all roadways. The vehicle mix provides the hourly distribution percentages of automobile, medium trucks and heavy trucks for input into the FHWA Model. Carlsbad Boulevard is expected to have 13,700 ADT according to the SANDAG Series 13 Traffic Prediction Model for the year 2035. The speed limit along this segment of Carlsbad Boulevard is 25 MPH. Based on the exterior noise model, the worst-case noise level from the roadway was found to be 63.3 dBA CNEL at the site. The modeling results are shown in Figure 3. No noise barriers, existing structures or topography that may affect noise levels were incorporated in the calculations. Figure 3: Future Noise Levels Project Name: Breakers View Date: 4-Apr-16 Project Number: 15-104 Location: Carlsbad Tralllc Volumes, Mix ancl seeecls I Autos Med. Trucks Heavy Trucks Mix Ratio by Percent 97.9 1.8 0.3 Propagation Rule Soft Roadway ADT Speed MPH CNEL @ SO Feet 60 CNEL (Feet) Carlsbad Boulevard 13,700 25 63.3 83 Noise Recluction due to Distance Distance Reduction Resultant Level Carlsbad Boulevard 50 0.00 63.3 Cumulative Noise Level 63.3 dBA CNEL 4/14/16 6 15143-02 Breakers View Beach House Noise Matthew castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATTACHMENT 6 Ldn em.ulllng, lne.. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 The proposed project includes an outdoor terrace and balcony along carlsbad Boulevard. Utilizing the same worst-case noise levels identified above for the building fac;ade the outdoor use area could be exposed to noise levels of 63 .3 dBA CNEL. This noise level is slightly above the normally acceptable level of 60 dBA CNEL but within the conditional compatible levels. As a design feature the project is proposing a solid planter area on the ground level and a solid railing at the second floor balcony that would help shield traffic related noise. To determine the noise level reductions from the solid planter box and railing, the Fresnel Barrier Reduction Calculations were modeled based on distance, source height and receiver elevation. It was found that the shielding would reduce the noise levels at the outdoor use area 3 or more decibels. Therefore, the traffic related noise level would be meet the 60 dBA CNEL goal and no outdoor impacts from the roadways are anticipated. Interior Noise Levels The methodology used to determine the resultant interior noise levels is based upon the exterior noise level minus the sound transmission loss as identified in the American Society of Testing and Materials (ASTM) guidelines: E413 &E90. Standard building construction will provide a noise reduction of approximately 12-15 dBA with a windows open condition and a minimum 20 dBA noise reduction with the windows closed. The exterior noise levels at the proposed structures calculated in terms of dBA are converted to the six octave band sound pressure levels between: 125 -4000 Hertz. Acoustical modeling of the proposed project dwelling units was performed in accordance with the above guidelines and included combining the transmission loss for each of the building components that will reduce the interior noise levels. Building components typically include the windows, exterior doors, and exterior walls. The total noise reduction is dependent upon the transmission loss of each building component, their subsequent surface area, quality of the building/construction materials, a building fac;ade and angle correction. The interior noise level is also dependent on the acoustical energy absorbed within the room based upon the Noise Reduction Coefficients (NRC). NRC is a scalar representation of the amount of sound energy absorbed upon striking a particular surface and the arithmetic value average of sound absorption coefficients indicating a material's ability to absorb sound. The absorption coefficients for individual surface areas such as carpet, drywall and furnishings are used to calculate the interior room effects. The calculated building noise reduction includes 4/14/16 7 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATT AC HM ENT 6 Ldn Comlu/Hng, Irie.. 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 both the room absorption characteristics and the transmission loss from the exterior wall assembly. The interior noise reduction calculations were performed using Ldn's interior noise model. The model converts the exterior sound level to octave band frequencies and accounts for the transmission loss, correction factors and room absorption. The floor plans used for this analysis were provided by Transpacific Architects, 2016. The following construction details were utilized for each of the building assemblies to determine the noise reduction characteristics: Exterior walls and roof assemblies must have a Sound Transmission Class (STC) rating of 46 or better. Exterior walls with this rating consist of 2"x4" studs or larger, spaced 16" o.c. with R-13 insulation minimum and an exterior surface of 7/8" cement plaster (stucco). Interior wall and ceiling surfaces shall be at least 1/2" thick gypsum or plaster. Roof assemblies should have a minimum of 1/2" sheathing, R-19 insulation and sealed to prevent noise leaks. Exterior entry doors should be of solid core construction and glass assemblies should be dual- glazed and acoustical sealant applied around the exterior edges. The window and door assemblies are generally the weakest noise reducing component but are the most convenient and cost effective elements to change if additional attenuation is needed. The STC ratings for the glass assemblies and exterior entry doors were calculated in the interior noise model and provided in the findings below. Bathrooms, kitchens, closets and corridors are not required to meet the 45 dBA CNEL standard and therefore were not modeled. All living areas where lower noise levels are essential for conversation and sleep should have carpeting installed; this includes bedrooms. The living and dining rooms were considered to have tile or hardwood flooring and modeling to account for less noise absorption. These rooms and were modeled to determine the interior noise reductions. If the modeled interior noise levels were found to be higher than 45 dBA CNEL in the living areas with the minimum assembly requirements described above additional modeling was performed to determine the minimum STC rating for the glass assemblies to further reduce interior noise levels below the acceptable interior threshold of 45 dBA CNEL. Eiodings The outdoor usable areas will be at or below the City's normally acceptable goal of 60 dBA CNEL with the incorporation of the solid planter and upper level solid rail. The building facade noise levels were determined to be as high as 63.3 dBA CNEL based on the analysis above. Basic 4/14/16 8 15143-02 Breakers View Beach House Noise Matthew Castriotta 3648 Carlsbad Blvd., LLC 29888 Sycamore Ridge Road Murrieta, CA 92563 ATTACHMENT 6 Ldn C8ntJuillng, I~ 42428 Chisolm Trail, Murrieta CA 92562 phone 760-473-1253 Fax 760-689-4943 calculations show that a windows open condition will typically reduce the interior noise levels 12- 15 dBA CNEL and not provide adequate interior noise mitigation. To meet the 45 dBA CNEL interior noise standard, an overall minimum interior noise level reduction of 18-19 dBA CNEL is needed for the proposed project. Therefore a closed window condition is required to reduce interior noise levels to comply with CCR Title 24 and City of Carlsbad requirements. The windows closed condition requires that mechanical ventilation is installed to move air within the structure and control temperatures. The mechanical ventilation must meet the jurisdictional requirements for these dwelling units. The necessary Sound Transmission Class and transmission losses for all glass assemblies are provided in Table 1. The modeled results with an anticipated interior noise level of 45 dBA CNEL or less are provided as an Attachment to this report. Table 1: Sound Transmission Class Ratings STC Octave Band Transmission Loss {Hz)1 Assembly Rating1 125 250 500 1000 2000 4000 Windows 26 21 17 25 32 37 38 Fixed Windows 26 17 16 22 31 35 27 Glass Doors 26 21 24 27 27 24 28 1 STC and Octave ratings used in Model No impacts are anticipated with the incorporation of the STC ratings provided in Table 1. If you have any questions, please do not hesitate to contact me directly at (760) 473-1253 or jlouden@ldnconsulting.net. Sincerely, Ldn Consulting, Inc. Jeremy Louden, Principal Attachments: Interior Noise Model Calculations 4/14/16 ATTACHMENT 6 9 1 5 1 4 3 0 2 B r e a k e r s V i e w B e a C h H 0 u s e N 0 i s e INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 1 A Living/Dining Exterior Noise Levels Exterior Assembly Stucco Windows Fixed Window Glass Doors Exterior Door Source NBS W-50-71 Champion Champion Thermal Tru NBS Monograph 77 Room Absorption (RA} Interior Olaracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 1020 30 24 420 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 125 46 27 26 21 26 17 26 21 26 16 NRC 125 0.28 0.15 0.45 0.32 0.07 0.09 0.8 0.56 125 -26.8 19.3 e Exposure Overall Reduction from Tranmission Loss + Room Absorption -Surfac Building Fa<_;ade Noise Level (dBA CNEL) 250 42 17 16 24 14 250 0.17 0.29 0.08 0.54 250 -26.8 19.3 ATTACHMENT 6 Ldn Consulting, Inc. Date: 4/12/16 Project# 15-143 Transmission Loss { dB} Frequency {Hz.} 500 1000 2000 44 46 49 25 32 37 22 31 35 27 27 24 23 30 36 Absorption c.oetfidents Frequency {Hz.} 500 1000 2000 0 .12 0.32 0.52 0.42 0.58 0.60 0.05 0.03 0.06 0.59 0.93 1.18 500 1000 2000 -26.8 -26.8 -26.8 19.3 19.3 19.3 4000 54 38 27 28 26 4000 0.30 0.48 0.09 0.87 4000 -26.8 19.3 21.5 63.3 Resultant Interior Noise Level (dBA CNEL) 42 * Corrections for Fa~ade Level was accounted for in the modeling. ATTACHMENT 6 INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 1 A Den/Bedroom 3 Exterior Noise Levels Exterior Assembly Stucco Windows Fixed Window Glass Doors Exterior Door Source NBS W-50-71 Champion Champion Thermal Tru NBS Monograph 77 Room Absorption {RAJ Interior Olaracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 216 0 0 84 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 46 26 26 26 26 NRC 0.28 0.45 0.07 0.8 Overall Reduction from Tranmission Loss + Room Absorption -Surfa Building Fac;ade Noise Level (dBA CNEL) 125 27 21 17 21 16 125 0.15 0.32 0.09 0.56 125 -22.0 16.3 ce Exposure Ldn Consulting, Inc. Date: 4/12/16 Proj ect # 15-143 4000 Transmission Loss {dB) Frequency {Hz.) 250 500 1000 2000 4000 42 44 46 49 54 17 25 32 37 38 16 22 31 35 27 24 27 27 24 28 14 23 30 36 26 Absorption Coeffidents Frequency {Hz.) 250 500 1000 2000 4000 0.17 0.12 0.32 0.52 0.30 0.29 0.42 0.58 0.60 0.48 0.08 0.05 0.03 0.06 0.09 0.54 0.59 0.93 1.18 0.87 250 500 1000 2000 4000 -22.0 -22.0 -22.0 -22.0 -22.0 16.3 16.3 16.3 16.3 16.3 24.5 63 3 Resultant Interior Noise Level (dBA CNEL) 39 * Corrections for F~ade Level was accounted for in the modeling. ATTACHMENT 6 INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 2 A Master Bedroom Exterior Noise Levels Exterior Assembly Stucco Windows Fixed Window Glass Doors Exterior Door Source NBS W-50-71 Champion Champion Thermal Tru NBS Monograph 77 Room Absorption {RA) Interior 01aractefistics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 360 38 36 68 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 46 26 26 26 26 NRC 0.28 0.45 0.07 0.8 Overall Reduction from Tranmission Loss + Room Absorption -Surfa Building Fac;ade Noise Level (dBA CNEL) 125 27 21 17 21 16 125 0.15 0.32 0.09 0.56 125 -24.2 18.8 ce Exposure Ldn Consulting, Inc. Date: 4/12/16 Project# 15-143 Transmission Lass {dB} Frequency {Hz.} 250 500 1000 2000 4000 42 17 16 24 14 250 0.17 0.29 0.08 0.54 250 -24.2 18.8 44 25 22 27 23 46 32 31 27 30 49 37 35 24 36 Absorption OJeffidents Frequency {Hz.} 500 1000 2000 0.12 0.32 0.52 0.42 0.58 0.60 0.05 0.03 0.06 0.59 0.93 1.18 500 1000 2000 -24.2 -24.2 -24.2 18.8 18.8 18.8 54 38 27 28 26 4000 0.30 0.48 0.09 0.87 4000 -24.2 18.8 23.9 63.3 Resultant Interior Noise Level (dBA CNEL) 39 • Corrections for Fa~ade Level was accounted for in the modeling. ATTACHMENT 6 INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 2 A Bedroom 2 Exterior Noise Levels Exterior Assembly Source Stucco NBS W-50-71 Windows Champion Fixed Window Champion Glass Doors Thermal Tru Exterior Door NBS Monograph 77 Room Absorption {RAJ Interior 01aracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 144 0 24 84 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 125 46 27 26 21 26 17 26 21 26 16 NRC 125 0.28 0.15 0.45 0.32 0.07 0.09 0.8 0.56 125 -21.0 17.4 Overall Reduction from Tranmission Loss + Room Absorption -Surfa ce Exposure Building Fac;ade Noise Level (dBA CNEL) Ldn Consulting, Inc. Date: 4/12/16 Project# 15-143 Transmission Loss { dB} Frequency {Hz.} 250 500 1000 2000 4000 42 44 46 49 54 17 25 32 37 38 16 22 31 35 27 24 27 27 24 28 14 23 30 36 26 Absorption C,oeffidents Frequency {Hz.} 250 500 1000 2000 4000 0.17 0.12 0.32 0.52 0.30 0.29 0.42 0.58 0.60 0.48 0.08 0.05 0.03 0.06 0.09 0.54 0.59 0.93 1.18 0.87 250 500 1000 2000 4000 -21.0 -21.0 -21.0 -21.0 -21.0 17.4 17.4 17.4 17.4 17.4 21.8 63.3 Resultant Interior Noise Level (dBA CNEL) 42 • Corrections for Fa~ade Level was accounted for in the modeling. INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 1 B Den/Bedroom 3 Exterior Noise Levels Exterior Assembly Source Stucco NBS W-50-71 Windows Champion Fixed Window Champion Glass Doors Thermal Tru Exterior Door NBS Monograph 77 Room Absorption (RA} Interior 01aracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 192 0 0 68 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 125 46 27 26 21 26 17 26 21 26 16 NRC 125 0.28 0.15 0.45 0.32 0.07 0.09 0.8 0.56 125 -21.2 16.1 ce Exposure Overall Reduction from Tranmission Loss + Room Absorption -Surfa Building Fa<_;ade Noise Level (dBA CNEL) 250 42 17 16 24 14 250 0.17 0.29 0.08 0.54 250 -21.2 16.1 ATTACHMENT 6 Ldn Consulting, Inc. Date: 4/12/16 Project # 15-143 Transmission Loss {dB} Frequency {Hz.} 500 1000 2000 4000 44 46 49 54 25 32 37 38 22 31 35 27 27 27 24 28 23 30 36 26 Absorption Coeffidents Frequency {Hz.) 500 1000 2000 4000 0.12 0.32 0.52 0.30 0.42 0.58 0.60 0.48 0.05 0.03 0.06 0.09 0.59 0.93 1.18 0.87 500 1000 2000 4000 -21.2 -21.2 -21.2 -21.2 16.1 16.1 16.1 16.1 24.6 63.3 Resultant Interior Noise Level (dBA CNEL) 39 • Corrections for Fa~ade Level was accounted for in the modeling. ATTACHMENT 6 INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 2 B Living/Dining Exterior Noise Levels Exterior Assembly Source Stucco NBS W-50-71 Windows Champion Fixed Window Champion Glass Doors Thermal Tru Exterior Door NBS Monograph 77 Room Absorption {RAJ Interior 01aracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 1128 78 150 384 24 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 46 26 26 26 26 NRC 0.28 0.45 0.07 0.8 Overall Reduction from Tranmission Loss + Room Absorption -Surfa Building Fa<,;ade Noise Level (dBA CNEL) 125 27 21 17 21 16 125 0.15 0.32 0.09 0.56 125 -27.6 20.4 ce Exposure Ldn Consulting, Inc. Date: 4/12/16 Project # 15-143 Transmission Loss { dB) Frequency {Hz.) 250 500 1000 2000 4000 42 44 46 49 54 17 25 32 37 38 16 22 31 35 27 24 27 27 24 28 14 23 30 36 26 Absorption Coeffidents Frequency {Hz.) 250 500 1000 2000 4000 0.17 0.12 0.32 0.52 0.30 0.29 0.42 0.58 0.60 0.48 0.08 0.05 0.03 0.06 0.09 0.54 0.59 0.93 1.18 0.87 250 500 1000 2000 4000 -27.6 -27.6 -27.6 -27.6 -27.6 20.4 20.4 20.4 20.4 20.4 20.6 63.3 Resultant Interior Noise Level (dBA CNEL) 43 • Corrections for Fa~ade Level was accounted for in the modeling. INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 2 B Master Bedroom Exterior Noise Levels Exterior Assembly Stucco Windows Fixed Window Glass Doors Exterior Door Source NBS W-50-71 Champion Champion Thermal Tru NBS Monograph 77 Room Absorption {RA} Interior Olaracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 432 38 36 68 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 46 26 26 26 26 NRC 0.28 0.45 0.07 0.8 Overall Reduction from Tranmission Loss + Room Absorption -Surfa Building Fac;ade Noise Level (dBA CNEL) 125 250 27 42 21 17 17 16 21 24 16 14 125 250 0.15 0.17 0.32 0.29 0.09 0.08 0.56 0.54 125 250 -24.2 -24.2 18.8 18.8 ce Exposure ATTACHMENT 6 Ldn Consulting, Inc. Date: 4/12/16 Project # 15-143 Transmission Loss { dB} Frequency {Hz.} 500 1000 2000 4000 44 46 49 54 25 32 37 38 22 31 35 27 27 27 24 28 23 30 36 26 Absorption O:Jeffidents Frequency {Hz.} 500 1000 2000 4000 0.12 0.32 0.52 0.30 0.42 0.58 0.60 0.48 0.05 0.03 0.06 0.09 0.59 0.93 1.18 0.87 500 1000 2000 4000 -24.2 -24.2 -24.2 -24.2 18.8 18.8 18.8 18.8 23.8 63.3 Resultant Interior Noise Level (dBA CNEL) 39 * Corrections for Fa~ade Level was accounted for in the modeling. ATTACHMENT 6 INTERIOR NOISE CALCULATIONS Project Name: Building (s) Floor Level Arch Plan: Room Type: Breakers View All 2 B Bedroom 2 Exterior Noise Levels Exterior Assembly Stucco Windows Fixed Window Glass Doors Exterior Door Source NBS W-50-71 Champion Champion Thermal Tru NBS Monograph 77 Room Absorption {RA} Interior G1aracteristics Source Carpet Army TM 5-805-4 Furnishings Army TM 5-805-4 Drywall Netwell Overall Absorption Factor (Furnished Room) Noise Reduction Area 120 0 24 84 0 Noise Reduction from Absorption based upon Floor Area Noise Level Increase for Defects and Exposed Surface Area STC 125 46 27 26 21 26 17 26 21 26 16 NRC 125 0.28 0.15 0.45 0.32 0.07 0.09 0.8 0.56 125 -19.8 17.3 Overall Reduction from Tranmission Loss + Room Absorption -Surfa ce Exposure Building Fac;ade Noise Level (dBA CNEL) Ldn Consulting, Inc. Date: 4/12/16 Project # 15-143 Transmission Loss { dB} Frequency {Hz.} 250 500 1000 2000 4000 42 44 46 49 54 17 25 32 37 38 16 22 31 35 27 24 27 27 24 28 14 23 30 36 26 Absorption Q:,effidents Frequency {Hz.} 250 500 1000 2000 4000 0.17 0.12 0.32 0.52 0.30 0.29 0.42 0.58 0.60 0.48 0.08 0.05 0.03 0.06 0.09 0.54 0.59 0.93 1.18 0.87 250 500 1000 2000 4000 -19.8 -19.8 -19.8 -19.8 -19.8 17.3 17.3 17.3 17.3 17.3 20.6 63.3 Resultant Interior Noise Level (dBA CNEL) 43 • Corrections for Fa~ade Level was accounted for in the modeling. ATTACHMENT 5 Ccityof Carlsbad DETERMINATION OF PROJECT'S SWPPP TIER LEVEL AND CONSTRUCTION THREAT LEVEL E-32 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www .carlsbadca.gov I'm applying for: ~ Grading Permit □ Building Permit □ Right-of-way permit □ Other Project Name: Breakers View Condominiums Project ID: _____ DWG #/CB# ____ _ Address: 3648 Carlsbad Boulevard APN 204-232-12 Disturbed Area:~ Ac Section 1: Determination of Project's SWPPP Tier Level (Check applicable criteria and check the corresponding SWPPP Tier Level, then go to section 2) Exempt -No Threat Project Assessment Criteria My project is in a category of permit types exempt from City Construction SWPPP requirements. Provided no significant grading proposed, pursuant to Table1, section 3.2.2 of Storm Water Standards, the following permits are exempt from SWPPP requirements: □ Electrical □ Patio D Fire Sprinkler D Mechanical D Mobile Home D Re-Roofing 0 Plumbing □Sign D Spa (Factory-Made) D Roof-Mounted Solar Array Tier 3 -Significant Threat Assessment Criteria -(See Construction General Permit (CGP) Section I.Bt □ My project includes construction or demolition activity that results in a land disturbance of equal to or greater than one acre including but not limited to clearing , grading, grubbing or excavation; or, □ My project includes construction activity that results in land disturbance of less than one acre but the construction activity is part of a larger common plan of development or the sale of one or more acres of disturbed land surface; or, □ My Project is associated with construction activity related to residential, commercial, or industrial development on lands currently used for agriculture; or □ My project is associated with construction activity associated with Linear Underground/Overhead Projects (LUP) including but not limited to those activities necessary for installation of underground and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire, towers, poles, cables, wires, connectors, switching, regulating and transforming equipment and associated ancillary facilities) and include but not limited to underground utility mark out, potholing, concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road, tower footings/foundation, pavement repair or replacement, stockpile/borrow locations. O Other per CGP _____________________ _ Tier 2 -Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat Assessment Criteria described above and meets one or more of the following criteria: ~ Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, □ Project will result in 2,500 sq. ft. or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • located within 200 ft. of an environmentally sensitive area or the Pacific Ocean; and/or, • disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical; and/or • disturbed area is located along or within 30 ft. of a storm drain inlet, an open drainage channel or watercourse; and/or • construction will be in itiated during the rainy season or will extend into the rainy season (Oct. 1 -Apr. 30) Tier 1 -Low Threat Assessment Criteria □ My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt permit type per above and the project meets one or more of the following criteria: • results in some soil disturbance; and/or • includes outdoor construction activities (such as roof framing, saw cutting , equipment washing, material stockoilino, vehicle fuelino, waste stockpiling) SWPPP Tier Level D Exempt D Tier 3 ~ Tier2 □ Tier 1 • Items fisted are excerpt from CGP. CGP governs criteria for triggers for Tier 3 SWPPP. Developer/owner shall confirm coverage under the current CGP and any amendments, revisions and reissuance thereof. E-32 Page 1 of 2 REV. 02/16 ATTACHMENT 5 SWPPP Section 2: Determination of Project's Construction Threat Level Construction Tier (Check applicable criteria under the Tier Level as determined in section 1, check the Threat Level corresponding Construction Threat Level, then complete the emergency contact and Level signature block below) Exempt -Not Applicable -Exempt Tier 3 -High Construction Threat Assessment Criteria: M~ Project meets one or more of the following: □ Project site is 50 acres or more and grading will occur during the rainy season □ Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA D High □ Soil at site is moderately to highly erosive (defined as having a predominance of soils with Tier3 USDA-NRCS Erosion factors k1greater than or equal to 0.4) □ Site slope is 5 to 1 or steeper □ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 -April 30) □ Owner/contractor received a Storm Water Notice of Violation within past two years Tier 3 -Medium Construction Threat Assessment Criteria □ Medium □ All projects not meeting Tier 3 High Construction Threat Assessment Criteria Tier 2 -High Construction Threat Assessment Criteria: M~ Project meets one or more of the following: □ Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA □ Soil at site is moderately to highly erosive (defined as having a predominance of soils with D High USDA-NRCS Erosion factors k1 greater than or equal to 0.4) Tier2 D Site slope is 5 to 1 or steeper □ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1 -Apr. 30) □ Owner/contractor received a Storm Water Notice of Violation within past two years □ Site results in 10,000 sq. ft. or more of soil disturbance Tier 2 -Medium Construction Threat Assessment Criteria ~ Medium ~ My project does not meet Tier 2 High Threat Assessment Criteria listed above Tier 1 -Medium Construction Threat Assessment Criteria: M:ii: Project meets one or more of the following: □ Owner/contractor received a Storm Water Notice of Violation within past two years □ Medium □ Site results in 500 sq. ft. or more of soil disturbance Tier 1 □ Construction will be initiated during the rainy season or will extend into the rainy season (Oct.1 -April 30) Tier 1 -Low Construction Threat Assessment Criteria D Low □ My project does not meet Tier 1 Medium Threat Assessment Criteria listed above I certify to the best of my knowledge that the above statements are true and correct. I wtll prepare and submit an appropriate Iler level SWPPP as determined above prepared in accordance with the City SWPPP Manual. I understand and acknowledge that I must adhere to and comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above. The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where ii can be shown that a lesser or higher SWPPP Tier Level is warranted. Emergency Contact Name: Telephone No: Jason Ianni 760-521-1228 Owner/Owner's Authorized Agent Name: Title: Jason Ianni Owner ~ Owner/Owner's AutflQJft'ed Agent Signature: Date:/J-~/O-/ %" ~ , FOR CITY USE ONLY Yes No City Concurrence: By: Date: E-32 Page 2 of 2 REV. 02/16 ATTACHMENT 7 C city of Carlsbad STORM WATER STANDARDS QUESTIONNAIRE Development Services Land Development Engineering 1635 Faraday Avenue (760) 602-2750 www.carlsbadca.gov E-34 I INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the city requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMPs) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual, refer to the Engineering Standards (Volume 5). This questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'STANDARD PROJECT' requirements or be subject to 'PRIORITY DEVELOPMENT PROJECT' (PDP) requirements. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionna ire and resubmit to the city. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A completed and signed questionnaire must be submitted with each development project application. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. -PROJECT INFORMATION PROJECT NAME: PROJECT ID: ADDRESS: 3648 Carlsbad Blvd. APN: 204-232-12 The project is (check one): D New Development 1lf Redevelopment The total proposed disturbed area is: 6,894 ft2 ( 0.16 ) acres The total proposed newly created and/or replaced impervious area is: 4 984 ft2 ( 0.11 ) acres If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the SWQMP # of the larger development project: Project ID SWQMP#: Then, go to Step 1 and follow the instructions. When completed , sign the form at the end and submit this with your application to the city. E-34 Page 1 of 4 REV 02/16 ATTACHMENT 7 -STEP1 TO BE COMPLETED FOR ALL PROJECTS To determine if your project is a "development project", please answer the following question: YES NO Is your project LIMITED TO routine maintenance activity and/or repair/improvements to an existing building I or structure that do not alter the size (See Section 1.3 of the BMP Design Manual for guidance)? □ if If you answered "yes" to the above question, provide justification below then go to Step 5, mark the third box stating "my project is not a 'development project' and not subject to the requirements of the BMP manual" and complete applicant information. Justification/discussion: (e.g. the project includes only interior remodels within an existing building): If you answered "no" to the above question, the project is a 'development project', go to Step 2. STEP2 TO BE COMPLETED FOR ALL DEVELOPMENT PROJECTS To determine if your project is exempt from PDP requirements pursuant to MS4 Permit Provision E.3.b.(3), please answer the following questions: Is your project LIMITED to one or more of the following: YES NO 1. Constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet the following criteria: a) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non- erodible permeable areas; □ {I b) Designed and constructed to be hydraulically disconnected from paved streets or roads; c) Designed and constructed with permeable pavements or surfaces in accordance with USEPA Green Streets guidance? 2. Retrofitting or redeveloping existing paved alleys, streets, or roads that are designed and constructed in □ ~ accordance with the USEPA Green Streets guidance? 3. Ground Mounted Solar Array that meets the criteria provided in section 1.4.2 of the BMP manual? D it If you answered "yes" to one or more of the above questions, provide discussion/justification below, then go to Step 5, mark the second box stating "my project is EXEMPT from PDP ... " and complete applicant information. Discussion to justify exemption ( e.g. the project redeveloping existing road designed and constructed in accordance with the USEPA Green Street guidance): If you answered "no" to the above questions, your project is not exempt from PDP, go to Step 3. E-34 Page 2 of 4 REV 04/17 ATTACHMENT 7 ·-STEP3 -~.~~' TO& CQMJIILS'.'fBD FQRALL !NEWO as~~ -~ To determine if your project is a PDP , please answer the following questions (MS4 Permit Provision E.3.b.(1)): YES NO 1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces collectively over the entire project site? This includes commercial, industrial, residential, mixed-use, □ fl and public development proiects on public or orivate land. 2. Is your project a redevelopment project creating andlor replacing 5,000 square feet or more of impervious surface collectively over the entire project site on an existing site of 10,000 square feet or □ ft more of impervious surface? This includes commercial, industrial, residential, mixed-use, and public development oroiects on oublic or orivate land. 3. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface collectively over the entire project site and supports a restaurant? A restaurant is ~ a facility that sells prepared foods and drinks for consumption, including stationary lunch counters and □ refreshment stands selling prepared foods and drinks for immediate consumption (Standard Industrial Classification (SIC) code 5812). 4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface collectively over the entire project site and supports a hillside development project? A hillside □ ~ development project includes development on anv natural slooe that is twentv-five percent or areater. 5. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface collectively over the entire project site and supports a parking lot? A parking lot is □ {$ a land area or facility for the temporary parking or storage of motor vehicles used personally for business or for commerce. 6. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious street, road, highway, freeway or driveway surface collectively over the entire project □ {$ site? A street, road, highway, freeway or driveway is any paved impervious surface used for the transoortation of automobiles, trucks, motorcvcles, and other vehicles. 7. Is your project a new or redevelopment project that creates and/or replaces 2,500 square feet or more of impervious surface collectively over the entire site, and discharges directly to an Environmentally ~ Sensitive Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of □ 200 feet or less from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the project to the ESA (i.e. not commingled with flows from adiacent landsJ. • 8. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface that supports an automotive repair shop? An automotive repair □ ~ shop is a facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013, 5014, 5541, 7532-7534, or 7536-7539. 9. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious area that supports a retail gasoline outlet (RGO)? This category includes □ ft RGO's that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic (ADT) of 100 or more vehicles oer dav. 10. Is your project a new or redevelopment project that results in the disturbance of one or more acres of land □ 4 and are expected to generate pollutants post construction? 11 . Is your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of ~ impervious surface or (2) increases impervious surface on the property by more than 10%? (CMC □ 21 .203.040) If you answered "yes• to one or more of the above questions, your project is a PDP. If your project is a redevelopment project, go to step 4. If your project is a new project, go to step 5, check the first box stating "My project is a PDP ... • and complete applicant information. If you answered "no" to all of the above questions, your project is a 'STANDARD PROJECT.' Go to step 5, check the second box statina "Mv project is a 'STANDARD PROJECT' .. ." and complete aoolicant information. E-34 Page 3 of 4 REV04117 ATTACHMENT 7 STEP4 TO BE COMPLETED FOR REDEVELOPMENT PROJECTS THAT ARE PRIORITY DEVELOPMENT PROJECTS (PDP) ONLY Complete the questions below regarding your redevelopment project (MS4 Permit Provision E.3.b.(2)): YES NO Does the redevelopment project result in the creation or replacement of impervious surface in an amount of less than 50% of the surface area of the previously existing development? Complete the percent impervious calculation below: Existing impervious area (A) = sq. ft. □ □ Total proposed newly created or replaced impervious area (B) = sq. ft. Percent impervious area created or replaced (B/A)*100 = % If you answered "yes", the structural BMPs required for PDP apply only to the creation or replacement of impervious surface and not the entire development. Go to step 5, check the first box stating "My project is a POP ... • and complete applicant information. If you answered "no." the structural BMP's required for PDP apply to the entire development. Go to step 5, check the check the first box stating "My project is a POP ... • and complete aoolicant information. STEPS CHECK THE APPROPRIATE BOX AND COMPLETE APPLICANT INFORMATION O My project is a PDP and must comply with POP stormwater requirements of the BMP Manual. I understand I must prepare a Storm Water Quality Management Plan (SWQMP) for submittal at time of application . -,¢ My project is a 'STANDARD PROJECT' OR EXEMPT from PDP and must only comply with 'STANDARD PROJECT' stormwater requirements of the BMP Manual. As part of these requirements, I will submit a "Standard Project Requirement Checklist Form E-36" and incorporate low impact development strategies throughout my project. Note: For projects that are close to meeting the PDP threshold, staff may require detailed impervious area calculations and exhibits to verify if 'STANDARD PROJECT' stormwater requirements apply. D My Project is NOT a 'development proj ect' and is not subject to the requirements of the BMP Manual. Applicant Information and Signature Box Applicant Name: Jason Ianni ~c Applicant Title: Owner Applicant Si~ Date: f/4//t> ~7 ' • Environmentally Sensitive Areas include but are not limited to all Clean Water Ni Section 303(d) 1mpa1red water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Mufti Species Conservation Program within the Plies and County of San Diego; Habitat Management Plan; and any other equivalent environmentally sensitive areas which have been identified by the City. This Box for City Use Onlv YES NO City Concurrence: □ □ By: Date: Project ID: E-34 Page 4 of 4 REV 04/17 ATTACHMENT 21 PRELIMINARY DRAINAGE STUDY TENTATIVE PARCEL MAP BREAKERS VIEW CONDOMINIUMS CITY OF CARLSBAD APN: 204-232-12 Prepared for: Jason Ianni 2337 Catalina Avenue Vista, CA 92084 Prepared by: bl-tA, Inc lancl planning, civil engineering, surveying 5115 Avenida Encinas, Suite L Carlsbad, CA 92008-4387 (760) 931-8700 April 26, 2016 July 25 , 2016 Revised May 10, 2018 w.o. 1013-1369-400 ATTACHMENT 21 TABLE OF CONTENTS I. DISCUSSION ........................................................................... 3 Vicinity Map ........................................................ 3 Purpose and Scope ................................................ 4 Project Description ............................................... 4 Study Method ...................................................... 5 Hydrology and Hydraulic Calculations ...................... 7 Conclusions ........................................................ 8 Declaration of Responsible Charge ........................... 9 II. EXHIBITS .............................................................................. 10 Existing Hydrology Map & Proposed Hydrology Map ... 10 III. HYDRAULIC CALCULATIONS ................................................ 11 Rational M ethod Hydrograph ................................. 12 Basin Storage and Outflow Calculations .................... 13 Flow-Through Planter Detail ................................... 15 Storage Basin Hydrograph Routing Model ................ 16 IV. REFERENCES ......................................................................... 21 Methodology -San Diego County Hydrology Manual StormTrap® Typical Specifications for "Single Trap" System bl-tA, Inc. Breakers View Condominiums Project Number land planning, civil engineerin g, surveying Preliminary Drainage Study 2 VICINilY MAP: Breakers View Condominiums Project Number Preliminary Drainage Study I. DISCUSSION ~ VICINITY MAP NTS ATTACHMENT 21 bJiA, Inc. land planning, civil engineering, surveying 3 ATTACHMENT 21 PURPOSE AND SCOPE: The purpose of this report is to publish the results of a hydrology and hydraulic analysis for the proposed condominium project at 3648 Carlsbad Boulevard, City of Carlsbad. The proposed project is a 0.16-acre site. The scope is to study the existing and proposed hydrology and hydraulics as it influences the surrounding properties during a 100-year frequency storm event, and make recommendations to intercept, contain and convey QlO0 to the historic point of discharge. PROJECT DESCRIPTION: The project is located at 3648 Carlsbad Boulevard, near the southwest corner of the intersection of Cherry Avenue and Carlsbad Boulevard, in the City of Carlsbad. The project proposes the development of two condominiums with parking areas. The disturbed area is 0.16 acres; the existing si te is 41 % impervious pre-redevelopment (2,859 square feet) and 72% impervious post- development (4 ,993 square feet). The proposed drainage basin matches th e existing drainage basin in terms of overall area and basin limits. Storm flows affecting the site are limited to the rainfall that lands directly on this property. The following table summarizes the existing condition runoff information from the site. Please refer to th e Existing Condition Hydrology Map for existing drainage area. TABLE I-Summary of Existing Condition Peak Flows Discharge Location Drainage Area 100-Year Peak Flow (acres) (cfs) Carlsbad Boulevard 0.16 0.62 The proposed drainage pattern will be similar as the ex1stmg drainage pattern with some modifications to incorporate the Low Impact Development (LID) Best Management Practices (BMPs) into the project design to mimic the impacts on storm water runoff and quality. The proposed runoff from the project is divided into two separate basin areas. 1) Runoff from the two condominium roofs will be captured and conveyed via roof drains to the proposed flow-through planter for storm water treatment. Runoff will be filtered through the media layer and aggregate storage layer before draining via underdrain pipe to a sidewalk underdrain at the southwest corner of the property. The sidewalk underdrain will direct flow south on Carlsbad Boulevard. Flow will then be intercepted by the existing curb inlet on Carlsbad Boulevard near the southwest corner of the property. 2) Runoff from the landscape, concrete sidewalk, and permeable pavement areas will flow to a 4"- dia PVC storm drain system. The permeable pavement areas will provide pollutant control Breakers View Condominiums Project Number Preliminary Drainage Study bJ.tA, Inc. land planning, civil engineering, surveying 4 • ATTACHMENT 21 treatment of the storm water before discharging into the storm drain system. The storm drain system will run along the northern and southern project boundaries and will direct flow into a proposed underground vault in the southeastern corner of the project. The underground vault will be sized to store the anticipated 0100 storm event volume. A sump pump in the underground vault will pump flows west to the flow through planter for treatment based at a maximum of 0.03 cubic feet per second (13.5 gallons per minute). At this rate the drawdown time of the underground vault is 3.5 hours, less than 96 hours. For stormwater runoff greater than a 100-year storm event, a backup pump will start automatically to empty the underground vault. The table below summarizes the expected cumulative 100-year peak flow rate. Please refer to the Proposed Hydrology Map. Per the San Diego County Rainfall Isopluvial maps, the design 100-year rainfall depth for the site area is 2.7 inches. TABLE 2-Summary of Developed Conditions Peak Flows Drainage Area 100-Year Undetained 100-Year Detained Discharge Location Peak Flow Peak Flow (cfs) (acres) (cfs) Carlsbad Boulevard 0.16 0.78 0.60 STUDY METHOD: The method of analysis was based on the Rational Method according to the San Diego County Hydrology Manual (SD HM). Drainage basin areas were determined from the proposed shown on the tentative parcel map. Initial time of concentration of 5 minutes is used for P6 for 100 year storm, see References. Rainfall Intensity= I= 7.44 *(P6)*(Tc) ~-0·645 P6 for 100 year storm = 2.7" In accordance with the County of San Diego standards, runoff coefficients were based on land use and soil type. An appropriate runoff coefficient (C) for each type of land use in the subarea was selected from Table 3-1 of San Diego Hydrology Manual multiplied by the percentage of total area (A) included in that class. The sum of the products for all land uses is the weighted runoff coefficient (2, [CA]). All landscape and pervious pavement areas were considered 0% impervious, and all roof and concrete areas were considered 95% impervious. For the existing condition, all landscape and concrete areas were tabulated and the total existing si te was calculated to be 41 % impervious. A runoff coefficient of 0.55 was assigned for the existing hydrology. For the proposed condition, OMA Breakers View Condominiums Project Number Preliminary Drainage Study bl--tA, Inc. land planning , civil engineering, surveying 5 ATTACHMENT 21 1, which encompasses the roof area draining to the LID planter, is considered 94 % impervious. A runoff coefficient of 0.87 was calculated for DMA l. DMA 2, which encompasses the landscape, concrete sidewalk, and pervious pavement areas draining to the LID planter, is considered 38% impervious. A runoff coefficient of 0.48 was calculated for DMA 2. See the runoff coefficients and impervious area percentages in the Hydrology and Hydraulic Calculations on the following pages. Also refer to the calculations for sizing the underground vault and LID BMP sizing. Breakers View Condominiums Project Number Preliminary Drainage Study bl-tA, Inc. land planning, civil engineering, surveying 6 • HYDROLOGY AND HYDRAULICS CALCULATIONS: EXISTING CONDITION HYDROLOGY IMPERVIOUS AREA= 0.066 PERCENT IMPERVIOUS 41.0% IO=CIA PERCENT IMPERVIOUS C I (in/hr) 0.55 7.11 DEVELOPED CONDITION HYDROLOGY OMA 1 -ROOF DRAINING DIRECTLY TO LID PLANTER IMPERVIOUS AREA= PERCENT IMPERVIOUS lo=c1A 0.088 100.0% PERCENT IMPERVIOUS ATTACHMENT 21 Tc=S MIN 41% A (ac) Q (cfs) 0.160 0.62 Tc=S MIN A (ac) Q (cfs) 0.09 0.54 OMA 2-AREAS DRAINING TO UNDERGROUND STORAGE VAULT, THEN PUMPED TO LID PLANTER IMPERVIOUS AREA= PERCENT IMPERVIOUS lo=c1A 0.026 38.0% PERCENT IMPERVIOUS Tc=S MIN A (ac) Q (cfs) 0.07 0.24 TOTAL DEVELOPED Q (cfs) 0.78 VOLUME OF STORM EVENT= CP 6A TOTAL PROJECT IMPERVIOUS AREA (ac) TOTAL PROJECT IMPERVIOUS PERCENTAGE 0.115 72% UNDERGROUND VAULT (CISTERN) SIZING CALCULATIONS TOTAL VOLUME OF STORM EVENT= CP6A 0.092 ac-in 333 ft3 333 ft3 bHA, Inc. Breakers View Condominiums Project Number land planning, civil engineering, surveying Preliminary Drainage Study 7 C ATTACHMENT 21 DECLARATION OF RESPONSIBLE CHARGE I hereby declare that I am the Engineer of Work for this project, that I have exercised responsible charge over the design of the project as defined in section 6703 of the business and professions code, and that the design is consistent with current standards. I understand that the check of project drawings and specifications by the City of Carlsbad is confined to a review only and does not relieve me, as Engineer of Work, of my responsibilities for project design. Bruce Rice R.C.E. 60676 Breakers View Condominiums Project Number Preliminary Drainage Study Date bl-tA, Inc. land planning, civil engineering, surveying 9 • - TOTAL VOLUME OF UNDERGROUND VAULT 100 YEAR STORM EVENT VOLUME PLUS 15% OF STORM EVENT VOLUME I TOTAL VOLUME ASSUME UNDERGROUND VAULT DIMENSIONS* *BASED ON STORMTRAP TYPE VII SINGLETRAP DIMENSIONS HEIGHT= 5'-8" WIDTH= 4'-10" LENGTH= 15'-4" VOLUME OF UNDERGROUND VAULT I VOLUME (ft3)=1 418 333 ft3 so ft3 383 ft3 ATTACHMENT 21 TIME TO DRAIN VAULT WITH FLOW PUMP OUT AT 0.03 CFS (13.5 GPM) 383 ft3/0.03 cfs= 12,765 seconds 1.-------'--3-.5-h_o_u_r_s ----~ CONCLUSION: The hydraulic calculations show that the proposed underground vault can sufficiently contain the anticipated Q 100 storm event volume of 383 cubic feet. This stored runoff can then be pumped to the flow through planter for treatment. Drainage patterns reflected on the Proposed Hydrology Map will increase the total developed runoff due to an increase in impervious area, however routing runoff, increasing the overall Time of Concentration, and implementing a flow-through planter, permeable pavements and a stormwater vault as proposed within this project will decrease the flow rate at the curb outlet on Carlsbad Boulevard. This project is effective at mitigating the potential impacts that development can have on stormwater runoff. By utilizing the proposed LID systems, this project mitigates both the quantity of runoff generated during storm, and the quality of runoff that will ultimately leave the property. It is our professional opinion that the recommendations provided in this report, and the drainage system as proposed effectively intercept, contain, convey, detain and treat the expected storm water runoff generated by this property to mimic pre-redevelopment conditions. Breakers View Condominiums Project Number Preliminary Drainage Study bl-tA, Inc. land planning, civil engineering, surveying 8 Breakers View Condominiums Project Number Preliminary Drainage Study C II. EXHIBITS EXISTING HYDROLOGY MAP &· ' PROPOSED HYDROLOGY MAP bl-IA, Inc. ATTACHMENT 21 land planning, civil engineering, surveying 10 • ATTACHMENT 21 \"~~~\ .. \ '--\' , ,,, J ;:4~:.:~: EXISTING HYDROLOGY MAP \ Lif/\. \ i f ~f~S BREAKERS VIEW CONDOMINIUMS \ \ .>~$ .·; ~·· /&\V . _. \ \\ ,,--·/t<q, /' \(,.' ,,/'f~ / --.•✓,j//;/;~·~;;:t,i:':<::.-··· , \ (::. ,,,,1 -----\ \ ,,,, .. ->( . ~~\ · \-l_'\ {'~,·,, •vi. V/ ( ... ··,~/---W-,/f::>>········· /1/ I.\ / \ \__ ,: \ \..., \\t · ---. / / 8"" ,,-·x--\) \ .. ~··----\·. .>----· ·:, ,,~}~~' /\ ,.· ' / ~<·~: \\::-:,:;//~.:': ' /, ::,_ \ / ~ ./' . ' . 0--.. ' \ ' \ / / .·· . /·· .. ·:•· . // ,-\ //,, ,:/· --, ·,._ . \---/ \ A. _,,,:'?",-:/~--\ ~r✓-,,, . /\ \ . -------,'-. \\ \ \ . ,• _ _,, / _,/·::;,;:• / \ ./\' \ \ \ \):.-\\ ' ~~ ~~ . "y· .. ,/ _ .. --.. ,,,:•:./·':.,.·1.::, ,• ..... ··'···, \ .... >·\ \ / \ ' '\ \i, ~ _.,/ ./ ' ,::.( .·>:-<>,/· .. • \ .· , ,,, \\..\ ... ··<r·· C ---./.,. ,,,, -----\ . ' ' ,, ~ ✓ ,\ .\ .~, ,/ ✓--~y:•' /! ', / \ :J >-< • 4 C ' ' . -:_\4 ,' ___,~ ~ V ,•· ,,, > ______ ,,, .. , \\' . \ , '. '----" '\ ,---::;~~-; .. ·: :-··.·~~:>··\··. . d ~ _,, ' '\; ~""' ~~'./ // / \ \ \ \\ \ .\ '\)'~·' :: ':~;--:',,,.:''.>··· '-...,..:~-/ \ \-, ', \ . ' ,t'y .,,:.• \ "\ \'\~ \\ \\ ••., ,\ \ ·~I·.·· .. ,,-··"'.<~<. \ ' \ '. ,-\\ \ -,;5;' \'~·-\\/ >-.4/t, \ \ \ \ ~ \ \ ' \ .... '' \ ,, \ \ \ \ ' \ " ,, \ . \/ \ \ ·. \ ' ,~ / /,;,,,/ \,., \ ', \ ' , ~~;?C 'x 1d7 .~·\ ·t ''//, .. ·~-~ '-\-\ ,\ 0 \ ' \ .. • ;~ \ '\\ \ \ "7 \ . \ \\' \ \ "' \ \ \"\ \ \ --r. \ ', \ " ' ,,. \ -.\ ~ \ \ ', \ ' \ ...... ,\, \ <: \ \ \ / . 0 '· \ \ -., I'\ \ \ ' " --·, ,., '\ ' \ ~ \ , \ ,,. .' . · .• •· X · u ~ ,. \ \ ~ \ \ \ : ,_;,.-- \\ ~··~. -. <\. \\ ~ \ \ \~\:.\.\( I \~ ,_,. \'-\ \ \ \ ' ' \ . \ '\: •. ,7 \ \ \ \ \\ \ '---. " \ ,·' p' \ \ \ \ ': " 11\ ~· 0~\ ,,, \ \\ \~0 \ ~~.. ,\\ \. / ,\\-\. .. \ \ \ \ \ ~ . .~\\.1\\ \ \', \ :\ \ ·, C. . ·~ . \ .'\ "\'\',__, \.\\~ , 4.<'1Y.\ \-:-, \_ '\.· 7 \ ;s. ~'~\.\' ?..."' \ \ \ \\ ' \ \ ~ (~"-\ \ "' ' ... ~ ,~ .. \, \ .. \ \ :}. \\, \ L ~ ~. \ \ ~-~\_.'\-·: .. -,' ~ \\'' ----'\ \'~ \ \ ~ '\ \\\~ ;• ~~-.. ~~~~'~ \/ \ t0z1 "~\\ \ \, \ ~ ' ~,\\\, I\;\ \' ~,, \ \\ -\._ \\ ' L •· • \ \ ~ ·\\', ~\~~ .. "' A '\. J \ \ , ' ,. ~ \ . ' ,\ \' \ ~ ''·\\\'-.'~\?\_ :·r-."\~--\ \'~··'\'\ ·"''--' \ \. ·"' ~\\\\~~ '\;~ ' '. \ \\, · .. \-~z5'}\, I \\ \ ~\ \ ~ \ . \.:. . ', \ \ \ ,, \\ \ \.• \• \ '\,\1;,_\\~'-\"-~~' ' /\,'\\,\ \\\ ,,:,0,'\ '\ '\: = @ LEG-~·-· SURFACE NOOE t 1 SURFACE now. 100 YfAR (CFS)0.62 PROJECT CHARACTERISTICS APN 204-232-12 BASIN All£A BASIN UUIT 11 OW 0/REC nON @ K:\Ovil 30\1369\D\YG\HVDRO&SVVMP\1013-1369-EX HYORO.dwg, 5/14nolB ll:08:26 AM SOIL TYPE PRO.ECT AREA 8 10 5 0 r-Sii-..., 10 0.16 ACRES SCALE: I" = 10' 20 JO ! < \ -( ' //---_,,,.-· /· / \:'''\. ) v✓······ //> ~' \ .__y·,,,-..•:•: ,r::? • ,.., r-; !,\ \ ,--✓- ... :; ;~ ,-,:,./ / , ;; ,/ /,, A \ \ \ \ \ / ,-' ·// /// // ,.-· \ /_,.,--····---- \ :·.::-'>s:i· ./ ',£~-~---·-_;f \ \ \ \ ,,,_. __ ... , .x \ \1 \ --! '76 ~\ . . _,,,.-····/\~\~t _.,/" .,,· \ ~\ ,,..,.,.. l\ \ ~ \ ,., '\\ \ ~ . ..--·__,,,-::--,. ~\ \~~\,,..-··· .. /, / , ~-\~ ,,/ ... :(/ ___ ,.,.-\ ~ \ ... •' .jY \ \ "'\ \ "' ,.;::::-·· \ \ ~ ,• .,:•· .. \ \ / .-· :;r"::· .· ,\\ Y,( / ~ ./ .,,,, .. --· , \t\ ../~✓-0. ----.--~\._..-'is. \ '\ u ..... . .. --· ' .. ·.1' ""'" \ \ \ \ ., v· l. , \\ ' J ,••' ~,;,1 , / \ \ \ J.,..--,,(' .::i'';• -•:~: \ \ \ I .. -··.:->...--_,,f!i';;:'-"'. (---:.· \ ' . ' \ :.," \ /_.-/ -<· ·""\ \ '· \ \ ./ \ ... -.<(· .:;::,.::/\·:.>\ \"/-\~.· _>·✓--~~ :--_,,.·-~,,,,::::>::.::/,,,. / A .---···' ,/ .-✓_,.-~- _,,-, ,,,,,:..-:'"'1 .. ,-::•''/ /// ,.,..--,) .. -/ / //> . bliA.lnc. EXISTING HYDROLOGY MAP BREAKERS VIEW CONDOMINIUMS CITY OF CARLSBAD land ~. cMI --...-ovr,g 5115 AVENIDA ENCINAS sum: "L· CARLSBAD, CA. 92006-4387 (760) 931-8700 ATTACHMENT 21 $ __ ,,.:,;,:,/ ·> '1 /, , ., ~v . !'-/ _,.,..._"'" ~ / f .· ' / _ . .-,•' •' f ,• ·.·-,,· 11 ,,..· '·'· .::•_·,,,,,' ~> ,.. i _:'/ PROPOSED HYDROLOGY MAP ~BAKERS VIEW CONDOMINIUMS c# ~.•·\· (:_·· _,./::'::·f\v1/ /'_/_/ C/¼;,,;/~;:~--~-:·:;;;:(?: ..... /} '_\.-\\vv ( ~# $ // :-"<i ,:~, \ \ \ "'/· / \ 1/ .... <, _✓ ... V7 ,?r:::::::-:>-···· \s'y \ .__,\ -,-'•~,_,,( \ / \. ,.,.',·\.·',.-"\· . ' ') '-,\ -;,-...cc_~ \.\ / / c-'> -K,'. / .( \ ,• , \ -~ \ ,\. . -:,-'4/ \ ,,..-:::,~}\\ . ' / _./··· \_.--·' <J> ... ~"\,:---., _ ,: -~ ..... '. 0%2/ ,,.-·<(;;:-::>' \ /. / / /,.. \ / .:\// .. ·· ' r~:·_-<'?~ ,.·/ /,/'·(' ~ 1/ ,,.-- PROJECT CHARACTERISTICS APN 204-232-12 SOIL TYPE B PRO.E:CT AREA 0.16 ACRES DISTURBED AREA 0.16 ACRES PROPOSED IMPERVIOUS AREA 0.11 ACRES PROPOSED P[RV/OUS AREA 0.05 ACRES '"ENGINEERED SOIL MIX SHALL PROV,0£ A MINIMUM SUSTAINED INFIL TRA nON RA TE OF 5"/HR. MIX SHALL 8£ SANDY LOAM TOP SOIL CONSJSnNG OF 50% SAND, JO% PLANTTNG SOIL, 20% SHREDDED HARDWOOD MULCH. 50.67 TC ----~ 24"X24" BROOKS PCC CA TCH BASIN W/ GRA TEO INLET 2" MULCH IMPERMEABLE LIN ::~~:ND aorrf!, ~R\,£:;,L~Al EXISTTNG 5/DEWALK~PIPE SLEEVE- !f~~AK UNDERDRAIN CARLSBAD BL~ . - S£'ftFR LATERAL EXISTTNG GR, SHALL BE 5 FT~ BELOW GRADE AT PROPERTY LINE EE.. 5• P£RFORA TED PVC PIPE W/ MIN .. J" AGGREGATE BELOW PLACE PIPE WITH PERFORA nONS AT THE INVERT BASIN OUTLET DETAIL SUMMARY NOT ro SCALE NOTES: 1) ROOF DRAINS TO FLOW-THROUGH PLANTER. 2) LANDSCAPE, CONCRETE SIDEWALK, AND PERMEABLE PAVEMENT DRAINS TO UNDERGROUND VAULT. J) ROOF SYSTEM TO INCORPORATE A FIRST SYSTEM TO CAPTURE THE FIRST WASH/OFF OF SEDIMENT, DEBRIS DURING A RAINFALL [VENT, OF DEVELOPED CONDITION RESULTS DISCHARGE LOCA nON I AREA (AC) 1 •00-Yf:AR UNO[TAIN[D I 100-Yf:AR DETAINED P[AK now (CFS) PEAK n ow (CFS) CARLSBAD BOULEVARD I 0.16 I 0.78 I 0.60 K:\Civil 30\1369\DWG\HYDRO&SWMP\1013·1369· PROP HYDRO.dwg, 5/14/2018 11:14:03 AM \ \ ' \ . . \ ,,. ' i· .·7-' _, , \ ,.,. / \ fP 1.,, , , .. /: _..::,,,:::··· . . )~•\ \ '',.'.<.' ,,,.<~ ,\,• ,,/ ...... ··:::>::: .. <>·tIC ,,,./ . /// / / / .:5 \~ ... . .. , ,». ,• / /__,;:,".•,,• /1/ / /// /// /,/~ \ ,<J \ . i:;,-, '/ ,, ,,,. . \-\ \ ,/._ ,,,-,;? ~~---······;_ .. ::··.:, . ...--··· /2 L~ >oi', \ \~\_;. /' ,~~ .• \ _),<,/ _,// '-'\. ~ , '" \ "--c-\~ ., , , .. V )(' \<)\ \'~~~9~/f../ \ . \\ \.-'.,_ ~ "''A"/ ~ .•. / \/'~:t\.\ ~~-' ,~-~---~·>",::/ \ \ ~ ,,..--\ \ '• \ ~ ' \ , \ ( ~. \ . <J> ·\<£, \ \ '· ~-\( .\ . '. \ \ \ . y' . ',\ \ . ~-\, \ ~/ /4 / ,------•'• /~~~ / / / / /,, __; ~I--.-~- \ \\ ___ \\\ J_.· ,/_/, ,• \\ \~~-\ / / ~~\ './,-~. ~6 \, ~ ·------.,,, \ \~ \; ~ \\ \ 0 \\ ~ \ \~ \' ~ \ \ ~ \; ' ~ ~ \\ ' tr>. \ '-\ \ \ b' / \ \~ \, \ _. \\ \_Mt-L 8' \ \ \ \' ~\ \,. \ \_ LEGE~:\\_7 : \\. -; 7->\, f"\'\.;~ %:· DUA 1 -ROOF AREAS DRAINING TO UD PU.NTER (0-0.52 CFS, ARCA~0.09 AC) ---fl///j/1/J OMA 2 -ARCAS DRAINING TO UNOERGROUND STORAGE VAULT (0,.0.2< CFS, ARtA=0.07 AC) l n ow-THROUGH PLANTER <<<I ---------IJ . ~1 P£R',10US PA VERS CONCRETE 51D[WALJ( ---------1 .. ' ·J OMA BOUNDARY ---------------------------- \.,.,,"' \ \, C \ \ ;::._\ \ { ,,.y· / / / / / _,.·· _),\,_ \ '\ ,.·•'/~ (:\ _./ ~~ \(' .->Y1/ /1/ / /1/ / / // .. _) "~ .y,:::'/ / / / / / / / / /•'/ \. )'':) \ ~ \ \:,)">,~ x,~ /./ /j~?<:/j~--_ ........ x. /· \ \'\\ '-J • /L \ / ,/ , \ \ \ ~ "'-'C 'J \ _,./,,,-_.,-::·',... \.' \ ~ \ . /,,·· _,/'t''':: . .-<~--, \ : ~ \ ,,.,,.· . ;#:Z,;:_" _,,.:;,\ \ '\ \ ~' / ( £/\ \ \\\ .· _,..,,.. _,,i/'';! ~ \ \ \ \ \\ .... ~-:-~::--··_,\,>'!:'' ,_.../ \ . \ / /'~---·:::.;;·~,,:::~_~; \\<---~ bliA.lnc. land plcrn,g, cM ~-~ 5115 AVENIDA ENCINAS SUITE •L• CARLSBAD, CA. 92008-4387 (760) 931-8700 10 5 0 10 20 JO i--\-++.._ I SCALE: 1 • = 10' PROPOSED HYDROLOGY MAP BREAKERS VIEW CONDOMINIUMS CITY OF CARLSBAD Breakers View Condominiums Project Number Preliminary Drainage Study III. ATTACHMENT 21 HYDRAULIC CALCULATIONS bl-rn, Inc. land planning, civil engineering, surveying 11 ATTACHMENT 21 RATIONAL METHOD HYDROGRAPH RATIONAL METHOD HYDROGRAPH PROGRAM COPYRIGHT 1992, 2001 RICK ENGINEERING COMPANY RUN DATE 5/9/2018 HYDROGRAPH FILE NAME Text1 TIME OF CONCENTRATION 5 MIN. 6 HOUR RAINFALL 2.7 INCHES BASIN AREA 0.16 ACRES RUNOFF COEFFICIENT 0.7 PEAK DISCHARGE O 78 CFS TIME (MIN)= 0 TIME (MIN)= 5 TIME (MIN)= 10 TIME (MIN)= 15 TIME (MIN)= 20 TIME (MIN)= 25 TIME (MIN)= 30 TIME (MIN)= 35 TIME (MIN)= 40 TIME (MIN)= 45 TIME (MIN)= 50 TIME (MIN)= 55 TIME (MIN)= 60 TIME (MIN)= 65 TIME (MIN)= 70 TIME (MIN)= 75 TIME (MIN)= 80 TIME (MIN)= 85 TIME(MIN)= 90 TIME (MIN)= 95 TIME (MIN)= 100 TIME (MIN)= 105 TIME (MIN)= 110 TIME (MIN)= 115 TIME (MIN)= 120 TIME (MIN)= 125 TIME (MIN)= 130 TIME (MIN)= 135 TIME (MIN)= 140 TIME (MIN)= 145 TIME (MIN)= 150 TIME (MIN)= 155 TIME (MIN)= 160 TIME (MIN)= 165 TIME (MIN)= 170 TIME (MIN)= 175 TIME (MIN)= 180 TIME (MIN)= 185 TIME (MIN)= 190 TIME (MIN)= 195 TIME (MIN)= 200 TIME (MIN)= 205 TIME (MIN)= 210 TIME(MIN)= 215 TIME (MIN)= 220 TIME (MIN)= 225 TIME (MIN)= 230 TIME (MIN)= 235 TIME (MIN)= 240 TIME (MIN)= 245 TIME (MIN)= 250 TIME (MIN)= 255 TIME (MIN)= 260 TIME (MIN)= 265 TIME (MIN)= 270 TIME (MIN)= 275 TIME (MIN)= 280 TIME (MIN)= 285 TIME (MIN)= 290 TIME (MIN)= 295 TIME (MIN)= 300 TIME (MIN)= 305 TIME (MIN)= 310 TIME (MIN)= 315 TIME (MIN)= 320 TIME (MIN)= 325 TIME (MIN)= 330 TIME (MIN)= 335 TIME (MIN)= 340 TIME (MIN)= 345 TIME (MIN)= 350 TIME (MIN)= 355 TIME (MIN)= 360 TIME (MIN)= 365 DISCHARGE (CFS)= 0 DISCHARGE (CFS) = 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0 1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.2 DISCHARGE (CFS)= 0.2 DISCHARGE (CFS)= 0. 78 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0.1 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 DISCHARGE (CFS)= 0 Breakers View Condominiums Project Number Preliminary Drainage Study For Flow-Through Planter bliA, Inc. land planning, civil engineering, surveying 12 L___ ATTACHMENT 21 BASIN STORAGE AND OUTFLOW CALCULATIONS FLOW THROUGH PLANTER Table 2.A, Overflow Capacity of 24"x24" Brooks Catch Basin Outlet Using Broad Crested Weir Formula equation (6-10) O=CLH1.5 where Coefficient C is 3.3. Basin Elev Coefficient Weir Length H (ft) Q (cfs) (ft) 0.5 3.3 8 0.067 0.46 0.6 3 .3 8 0.167 1.80 0.7 3.3 8 0.267 3.64 0.8 3.3 8 0.367 5.87 0.9 3.3 8 0.467 8.43 1.0 3.3 8 0.567 11.27 Table 2.B, Capacity of 4.0"-dia Draindown Orifice Plate Using standard submerged Orifice Flow Equation (6-12) O=CoA(2gH)0 5 Basin. Elev. Basin Orifice Size Diameter Coefficient Head (ft) Odrain (cfs) (ft) Depth (ft) Dia. (ft) Area (sf) 49.50 0.00 0.3333 0.08727 0.62 1.3333 0.499 49.60 0.10 0.3333 0.08727 0.62 1.5833 0.544 49.70 0.20 0.3333 0.08727 0.62 1.8333 0.586 49.80 0.30 0.3333 0.08727 0.62 2.0833 0.625 49.90 0.40 0.3333 0.08727 0.62 2.3333 0.661 50.00 0.50 0.3333 0.08727 0.62 2.5833 0.696 50.10 0.60 0.3333 0.08727 0.62 2.8333 0.729 50.20 0.70 0.3333 0.08727 0.62 3.0833 0.761 50.30 0.80 0.3333 0.08727 0.62 3.3333 0.791 50.40 0.90 0.3333 0.08727 0.62 3.5833 0.820 50.50 1.00 0.3333 0.08727 0.62 3.8333 0.849 b~A, Inc. Breakers View Condomin iums Project Number land planning, civil engineering, surveying Preliminary Drainage Study 13 ATTACHMENT 21 Table 2.C-Main Basin Depth vs. Storage and Discharge Information Bottom Basin Area (sf) = 231 Elev Volume CF Depth Vlume acre-ft Outflow 49.50 103.95 0 0.0024 0.4987 Total Storage in Soil Media*** 49.60 127.75 0.1 0.0029 0.5439 49.70 152.95 0.2 0.0035 0.5857 49.80 179.55 0.3 0.0041 0.6246 49.90 207.55 0.4 0.0048 0.6613 50.00 236.95 0.5 0.0054 1.1538 50.10 267.75 0.6 0.0061 2.5307 50.20 .. 299.95 0.7 0.0069 4.4030 50.30 333.55 0.8 0.0077 6.6606 50.40 368.55 0.9 0.0085 9.2455 50.50 404.95 1.0 0.0093 12.1200 ***assuming 25% Void Ratio in Engineered Soil Layer (typical value) Drawdown calculator: Flow through orifice plate gol.€rns drain-down flow 352 Basin Volume@ 6" Depth (ft3): 1----------1 0. 70 Q of 4" orifice plate at 6" Basin Depth (cfs) 1----------1 0.14 Drawdown time (hrs)< 24 hrs .__ ___ __, Breakers View Condominiums Project Number Preliminary Drainage Study ✓ 61-tA, Inc. land planning, civil engineering, surveying • '--- ATTACHMENT 21 FLOW-THROUGH PLANTER DETAIL Not to Scale 'JO 67 TG 24 "X24 .. BRnOKS P(I CATCH BA C:.!N N/ C,RA T[O IN ET '[NG!NffR[D SOI~ Ml'< SHAL~ PRO ✓ID[ A MINIMJM SJSTA!NED !NFIL TRA TION RAT[ OF c:, '/HR MIX SHALL 8[ SANDY LOAM rop SOI' '::ONSI::, T/W; OF 5:]% C::.AND, 3')% PLAN T!NC 50/:_, 2'.Jt /-IR£DD[D HARDl/!]OD MU_ .. H 2" MJLCH- DffP R00TED, DENSE, DROUGHT TOLERANT PLANTING SU/TAB [ FOR NELL DRAINED SOI~ R[STRV'T[R PLAT[ TO LIMIT-, FL OIi (;U f OF P/r PIP[, 4 "-DIA LID ORIFICE 2·· OF P[A CRA /[L !MP[RM[ABL[ LIN[R ON ✓ERTICAL NALLS ANC BOTT M, PER S:JILS R[PnRT EXh TIN(., ::,/DUIALK SIDEWALK UND[RDRAIN- 415:] FL R/W CARLSBAD BLVD--.-. ~~~~~~===:~6~~~W 4 7 70 FL //~-~, OUT--~ 47 72 FL// L6" HOP[ IN___,. OUTLET PIP[ SEWER LATERAL [XISTING GROUND SHALL 8[ 5 FT~ BELO!✓ GRAD[ AT ~ PROPERTY LIN[ !B" [N'J/NffRED SOIL MIX' 49 5 FF P£RM£AB [ PAV[R::, 6" PERFORATED PIC PIP[ W/ MIN. 3" AGGR[GA TE BELOW PLACE PIPE WITH PERFORATIONS AT THE INVERT BASIN OUTLET DETAIL Breakers View Condominiums Project Number Preliminary Drainage Study NOT TO SOI [ b~A, Inc. land planning, civil engineering, surveying 15 ATTACHMENT 21 STORAGE BASIN HYDROGRAPH ROUTING MODEL **************************************************************************** HYDRAULICS ELEMENTS -II PROGRAM PACKAGE STORAGE BASIN HYDROGRAPH ROUTING MODEL **************************************************************************** (c) Copyright 1983-2016 Advanced Engineering Software (aes) Ver . 21 .1 Release Date : 01/J7/2016 License ID 1459 Analysis prepared by : BHA INC . 5115 AVENIDA ENCINAS , SUITE L CARLSBAD , CA 92008 ************************** DESCRIPTION OF STUDY ************************** * FLOW THROUGH PLANTER DETENTION CALCULATIONS * 100 YEAR STORM EVENT * ************************************************************************** FILE NAME : K:\HYDRO\1369\1369Bl .DAT TIME/DATE OF STUDY : 13 :37 05/09/2018 ENTERED INFORMATION : TOTAL NUMBER OF INFLOW HYDROGRAPH INTERVALS= 74 CONSTANT HYDROGRAPH TIME UNIT(MINUTES) = 5 .000 ASSUMED INITIAL DEPTH(FEET) IN STORAGE BASIN= ENTERED INFLOW HYDROGRAPH ORDINATES (CFS) : *INTERVAL FLOW *INTERVAL FLOW *INTERVAL * NUMBER (CFS) * NUMBER (CFS) * NUMBER * 1 : 0.00* 2 : 0 .00* 3: * 4 : 0.00* 5 : 0.00* 6: * 7; 0.00* 8 ; 0.00* 9; * 10 : 0.00* 11 : 0 .00* 12 : * 13 ; 0 .00* 14 : 0 .00* 15: * 16 : 0 .00* 17 : 0 .00* 18 : * 19 : 0 .00* 20 : 0 .00* 21 : * 22 : 0 .00* 23 : 0.00* 24 : * 25 : 0 .00* 26 : 0 .00* 27 : * 28 : 0 .00* 29 : 0 .00* 30 : * 31 : 0 .00* 32 : 0 .00* 33 : * 34 : 0 .00* 35 : 0 .00* 36 : * 37 : 0 .00* 38 : 0 .00* 39 : * 40 : 0 .10* 41 : 0 .10* 42 : * 43 : 0 .10* 44 : 0 .10* 45 : * 46 : 0 .10* 47 : 0.10* 48 : * 49 : 0 .20* 50 : 0 .78* 51 : * 52 : 0 .10* 53 : 0 .10* 54 : * 55 : 0 .00* 56 : 0 .00* 57 : * 58 : 0 .00* 59 : 0 .00* 60 : * 61 : 0 .00* 62 : 0 .00* 63 : * 64 : 0 .00* 65 : 0 .00* 66 : * 67 : 0 .00* 68 : 0 .00* 69 : * 70 : 0 .00* 71 : 0 .00* 72 : * 73 : 0 .00* 74 : 0 .00* 0 .00 FLOW * (CFS) * 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .10* 0 .10* 0 .20* 0 .10* 0 .10* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* 0 .00* DEPTH-VS .-STORAGE AND DEPTH-VS .-DISCHARGE INFORMATION : bl-tA, Inc. * * * Breakers View Condominiums Project Number land planning, civil engineering, surveying Preliminary Drainage Study 16 ATTACHMENT 21 TOTAL NUMBER OF BASIN DEPTH INFORMATION ENTRIES= 11 *BASIN-DEPTH STORAGE OUTFLOW **BASIN-DEPTH STORAGE OUTFLOW * * (FEET) (ACRE-FEET) (CFS) ** (FEET) (ACRE-FEET) (CFS) * * 0 .000 0 .000 0 .000** 0 .100 0 .003 0 .544* * 0 .200 0 .004 0 .586** 0 .300 0 .004 0 .625* * 0 .400 0 .005 0 .661** 0 .500 0 .005 1 .154* * 0 .600 0 .006 2 .531** 0 . 700 0 .007 4 .403* * 0 .800 0 .008 6 .,661** 0 .900 0 .009 9 .245* * 1 .000 0 .009 12 .120** **************************************************************************** INITIAL BASIN DEPTH(FEET) = 0 .00 INITIAL BASIN STORAGE(ACRE-FEET ) = 0 .00 INITIAL BASIN OUTFLOW(CFS ) = 0 .00 BASIN STORAGE , OUTFLOW AND DEPTH ROUTING VALUES : INTERVAL {S-O*DT/2) {S+O*DT/2) NUMBER (ACRE-FEET) (ACRE-FEET) 1 0 .00000 0 .00000 2 0 .00103 0 .00477 3 0 .00148 0 .00552 4 0 .00195 0 .00625 5 0 .00252 0 .00708 6 0 .00143 0 .00937 7 -0 .00261 0 .01481 8 -0 .00826 0 .02206 9 -0 .01524 0 .03064 10 -0 .02334 0 .04034 11 -0.03244 0 .05104 WHERE S=STORAGE(AF ) ;O=OUTFLOW (AF /MIN .) ;DT=UNIT(MIN .) *UNIT-HYDROGRAPH STORAGE-BASIN ROUTING* NOTE : COMPUTED BASIN DEPTH, OUTFLOW , AND STORAGE QUANTITIES OCCUR AT THE GIVEN TIME . BASIN INFLOW VALUES REPRESENT THE AVERAGE INFLOW DURING THE RECENT HYDROGRAPH UNIT INTERVAL . GRAPH NOTATION : "I "=MEAN UNIT INFLOW; "O"=OUTFLOW AT GIVEN TIME TIME INFLOW (HOURS) (CFS ) OUTFLOW (CFS) 0 .00 0 .08 0 .00 (BASIN DEPTH (FEET ) = 0 .17 0 .00 0 .00 (BASIN DEPTH (FEET) = 0 .25 0 .00 0 .00 [BASIN DEPTH (FEET) = 0 .33 0 .00 0 .00 (BASIN DEPTH (FEET) = 0 .42 0 .00 0 .00 (BASIN DEPTH (FEET) = 0 .50 0 .00 0 .00 (BASIN DEPTH (FEET) = 0 .58 0 .00 0 .00 (BASIN DEPTH (FEET) STORAGE (ACRE-FT ) 0 . 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0. 0 . 1. bl-fA, Inc. 1. Breakers View Condominiums Project Number land planning, civil engineering, surveying Preliminary Drainage Study 17 ATTACHMENT 21 0 .67 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 0 .75 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 0 .83 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 0 .92 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1.00 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1.08 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 1.1 7 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1 .25 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 1. 33 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1. 42 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 1. 50 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1. 58 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 1. 6 7 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1 .75 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1. 83 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET ) = 0 .00] 1. 92 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 2 .00 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 2 .08 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 2 .17 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 2.25 0 .00 0 .00 0 .000 0 [BASIN DEPTH(FEET) = 0 .00] 2 .33 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 2 .42 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 2.50 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 2 .58 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 2 .67 0 .00 0 .00 0 .000 0 [BASIN DEP TH(FEET ) = 0 .00] 2 .75 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 2 .83 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 2 .92 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET) = 0 .00] 3 .00 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 3 .08 0 .00 0 .00 0 .000 0 [BASIN DEPTH (FEET ) = 0 .00] 3 .17 0 .00 0 .00 0 .000 o [BASIN DEPTH (FEET ) 0 .00] Breakers View Condominiums b~A, Inc. Project Number land planning, civil engineerin g, surveying Preliminary Drainage Study 18 3 .25 0 .00 0 .00 [BASIN DEPTH (FEET ) = 3 .33 0 .10 0 .08 [BASIN DEPTH(FEET) = 3 .42 0 .10 0 .10 [BASIN DEPTH(FEET) = 3 .50 0 .10 0 .10 [BASIN DEPTH(FEET) = 3 .58 0 .10 0 .10 [BASIN DEPTH(FEET) = 3 .67 0 .10 0 .10 [BASIN DEPTH(FEET) = 3 .75 0 .10 0 .10 [BASIN DEPTH (FEET ) = 3 .83 0 .10 0 .10 [BASIN DEPTH (FEET ) = 3 .92 0 .10 0 .10 [BASIN DEPTH(FEET) = 4 .00 0 .20 0 .18 [BASIN DEPTH(FEET) = 4 .08 0 .20 0 .20 [BASIN DEPTH (FEET ) = 4 .17 0 .78 0 .60 [BASIN DEPTH (FEET ) = 4 .25 0 .10 0 .26 [BASIN DEPTH(FEET) = 4 .33 0 .10 0 .14 [BASIN DEPTH(FEET) = 4 .42 0 .10 0 .11 [BASIN DEPTH(FEET) = 4 .50 0 .10 0 .10 [BASIN DEPTH(FEET) = 4 .58 0 .00 0 .02 [BASIN DEPTH(FEET) = 4 .67 0 .00 0 .00 [BASIN DEPTH (FEET) = 4 .75 0 .00 0 .00 [BASIN DEPTH (FEET) = 4 .83 0 .00 0 .00 [BASIN DEPTH (FEET) = 4 .92 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .00 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .08 0 .00 0 .00 [BASIN DEPTH(FEET) = 5 .17 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .25 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .33 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .42 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .50 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .58 0 .00 0 .00 [BASIN DEPTH (FEET) = 5 .67 0 .00 0 .00 [BASIN DEPTH ( FEET) = 5 .75 0 .00 0 .00 [BASIN DEPTH (FEET) Breakers View Condominiums Project Number Preliminary Drainage Study ATTACHMENT 21 0 .000 0 0 .00] 0 .000 OI 0 .01] 0 .001 OI 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .001 or 0 .03] 0 .001 0 0 .04] 0 .004 0 I 0 .23] 0 .001 I 0 0 .05] 0 .001 IO 0 .02] 0 .001 0 0 .02] 0 .001 0 0 .02] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 O 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00) 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00) 0 .000 0 0 .00) 0 .000 0 0.00) 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00) bl-tA, Inc. land plann ing , civil engineering, surveying 19 5 .83 0 .00 0 .00 [BASIN DEPTH(FEET ) = 5 .92 0 .00 0 .00 [BASIN DEPTH (FEET ) = 6 .00 0 .00 0 .00 [BASIN DEPTH (FEET ) = 6 .08 0 .00 0 .00 [BASIN DEPTH(FEET ) = 6.17 0 .00 0 .00 [BASIN DEPTH(FEET ) = Breakers View Condominiums Project Number Preliminary Drainage Study • ATTACHMENT 21 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0 .000 0 0 .00] 0.000 0 0 .00] bHA, Inc. land planning, civi l engineerin g, surveying 20 L_ • I Breakers View Condominiums Project Number Preliminary Drainage Study IV. REFERENCES ATTACHMENT 21 bl-tA, Inc. land planning, civil engineering, surveying 21 I • ATTACHMENT 21 METHODOLOGY -SAN DIEGO COUNTY HYDROLOGY MANUAL PROJECT SITE LOCATION •·1-u:..r•1ri:·r-11-,,,ffi,, H-'-1+1 1 '-tl· , 'l-L ,. I' ~ .. ,,, .. !' .l !I ~· :!!t11I~J .. Lf1r IJr IIJ-!-r1 i·rlo . ' •I ! ·t ~!, '-++m-11 :~1j ·l•(:·r:::: :~ ----1· • '. ;:...JJ ., •. I .-• • • I I l I 11 l-' CD '+-l-'-+ ., . " ' ' ' I • U • -· ' -. . d±• . .,_ -4-,,~---· a ,·-,J-1 'IT. -I' 1 -J ___!_ -Ir :. ..,~. ',,;.,~r,ge . -j-: , .. ' I l , ·1 ~~r:l r· 1 o-T"t...-~... · I -• t. UJ ! •·~/7 I _II ::.'. .. 1 1 . ,--• ..I I • • , f ;..: • -: , " . 1 1 , f _r ,~· I ....._t • I 33•30' 7 . ! County of San Diego Hydrology Manual ' • ' I ,· i 1 '... ·1 . :.~_l.·'.'...1 • .-l -. -...,. ' • " I j l": •· h r L t ).,L . -"f",~ -+-::1:·,-I I !·. ·, 1 '-; I . ····, . .. . . . -.,..... 1 · I i . . . ·•, ·•• -+ I :-II . iT,:;-J:,., ' ' i,. . .J·.1.1);~! . 1'1 -~-•R~.i .. f::,:;. -1-·•·-... , : )'::.. i h , , 7 ,., :-..-,-r .-1. -. ,.1.. .,.,... -I · 1.1 r~n •,, · ·, -, ·•-,·~ H,!,. • .1\I :,,l kL ··J ·• -;;1 I:' · • V}H , "'"l-1 ., ,-, ,-133•~ ' ' ' -, r·., r• , .. 1 -i •1 · r ·-· • · ·-1 l[f .. r •·•r ,; 11\I l l \ I• 1, ........... _ u J ,.I 1. U r:·, I' I I L1...~L -j ::l /·,.! ~t.1;~ i-' Li I ~:._rr,-1· ,·~11••J L• .!. .WI j w.,...--~ . . .. ~ ~"··· .. 1 ·,·~1-I . ~•.2 .1 1 , • -f , ·... r·=... • I I,,·, ,=u~-, p; ,.T -1~:t:,14 .!N.,1,Y<.'Wa~~~ --··~, .. ,.. · ·-.. .. ~ h-,, r---~, 1' llit:.Jff'i:!'>!d~ l ., . I 1 ·• r rn ' ,. I -, .. '.,'fir-... =.._,""'-'~ ---+-i-+-1 . ·',:-r l I :•~ . . I, . --'· ~ r J I. ,·:1 . ·-· f LJ J ,-L-u.--.~,_,.... : ' I . 8. -~·~: · .,,..,..,".._,_.....l +-..-1'.i..+-l-l,l -'tt-;;-:-~=-f · ~·00 I • -n ~- 1 ;. t J l ' ,:-=,'"-"'"-l-tl,1--1-'r'lr'I l--~t-t-H-----l---3- 101 '···h-l, l·1 L! ~(l;g~:F . .. I I --0·' , , · :-:-' i"I IT '--f 1 ·.JS:1.-h_ .I , u.:· :·· ~l · l"1 r 1-,-...1 T"· "!;[•.'I. : 1 .. ·, . ! I ~ er , ,·, .-j 1 I • ·•··t·:+ .. .1, · · l · 1 1, J '1· =1 ~H-jl !-i I -JI_ 11 .,...,._."""'-'' ·-.~F::! . .r-~_,..... .. ··.··,·, ·.·· • -·11 -· -t J~ ~~~~~ ~-~~ l '·· r•1•-i-;n· i"I '-'-'-I . :.•' • L I 11 ~ 7'..,-•.A-'-14-,.r -1\ \ •. ~ ,· •. ,J "T :•,+:_•.! ,r.: i !• q .. / .. p-l. r ~'. l&~~~cti +.!/.~.-,,:,...::.J~ L. •.l .\ \:-,i \J •~, .,,f,;-,1n -= ,3nsiJ --,-;-'-• I I -, • •. ,. j t .. rn,-.-Ll.1 ··t_r1~1 ' .. , s1. 1 .. :::n.L [LL-::-UJ7,pf1,,_~.-HTI~l-b""",'-I l'ti"""t_T' i l;J•l,..J;i ,:-H~~~:::t'i""r ,_;.~ L', f : I . 11111 'II!' ' j • I ' J I f • " - -! . J i i-. ! . --, . I ._ ' ,:.I.I r:i t !..!~. •1 !±I I -. ,-,_, ·--i--: ;-s-: 1 ,_, _ • ,J_ .. 1 • • ,-,--· ., ,~, ~! 1-1 .• .. , Lr;'-'-, t_:--. ,-' , '!!..; Rainfall Isopluvials 100 Year Rainfall Event -6 Hours [ ······--lsopluvial (inches) GPS COORDINATES: P6=2.7" P6/P24= 56% DPW ~~~~ s1fiGI~ ~~ lb\ ........ :: IA.ru< u, .. u~ N nQW#ll"""1IICICD¥!'fflUJl'"l#Wfngl--~,. ~t.Oll-...... ...- :,-1.[": I ,:! •~ · .. 1 , .. I ,Jj-r• 1-' I J '1,1-~ _.,J.1 1.1 I .JI J t I I I J . ' ~ .-1, _ =! i: 0 ~ , ·i:' 1 =-==-..::.=.=:"..=:.-==.:---~ + :==:-.::..~~...:... ----'l,IICAA m I ' •32'3o! I I I j I ' I ' I.... "j .-, I f .i ,:w-:f'-i :r 0"' Jr·,----,-1:1,-~ 1 -1 L ' _; j -L-..__l. _ _1 ·-· _ , , .. I' I :0 I • .- :Z•rr:-,J ' __ H_ . 1· -~-l 1fi ''-=- I -----------z . -----""-----s --l 0 3 MIies N ...... PROJECT SITE LOCATION -1 ,-1-'.:jr,TI '1 ! ',-'r'1..!' rr' ~:-i I ,I ·-mr -: I ··,,-1•1 ', ! 'I.-.... ' I 1r-1-,~r,,' I. . ' I -· ~-.u O ' • • · r,, I I t I I I --1 ·-· I I r,,. .-.. -•• J.:.. ... I I ii jl lj ?i I I VJ .,_ .I •. 'r l I ·, ·1~, ,--, 1ml -.... W..-c.;b l~ ~-I ,_ I • • .i.! . .-~.i 1 ,· ,_ · H ~ I ( · -· :0 _ __,....J.+.4i.j ,, 1 • ., • • i 1 ! i'; 1-/; -,_, 1 .. , -L ~1---.-+-r-T i-r· ~ -, · :-, r t · r · I :: r _, ,.., • ·, • ' -l I ' ; I l • ; 1-33 J r -~...:...J..I. -. -,-...,..----... , I LIJ ,~1 fT I I I J y I I I I I ,--, .. , ; .-,•-•f I +-- 1 ~ I I;-,· ·-• • I • • • ~·7"" 1 , I 1 ·'J .' otJl-j • ' 1 ~ ,-, rL ·a. ,•1.,:.:.-1 ;, fttp;i7r)ff'1h17ti~:E~B-~'i-+~'i~+,;::~1:-FFF?k:j;:;~h!-+J---l=i., -__,_J T' ~ . '•' I -i 1 : , j ,:-D ·:::-::-.~:r: .1: '"•· .. , H ·r-'..:r j I I I -·,··, ' ,,· -.6 F=..;T --1 ---. '5-ff••··~' -t. .... .. ~"" ', ' '...!..' ·--:j fl .J I I. -~>+-JI-\H l ,• .. , ' ' I j ···,•.' ''I' I I ···•I . ·! l• ,-, 1 ' • ; • I l t -i l r·1 \ ' r, . i I ··•V f J--, t I I r, -' . -;-J· J-\t• I • . . ! I !..! . ·-~ 1· H-1.1 · ;\ ,' ···,.i • ,-y---....._ • ~ I_, L'...: 'I I :· .... .I· i:I. u_:·:, 1-: ,-; r. rt ··j:t<··:·: :· ······· TTf , __ ....,_ '· .1.1.~,~ . I T'-:1-~'"f;_~ '"j"iTI, -~·'•' !-', u.L , •~~~~~ · • -f ., , , l}-1 ,-,·; i:-i-. •; I'~. ~ nr .. ,·-;•.~ ~ .. -:..i !1..r·:..r · "' ~--· :r--r.-----;--+--,-t-t-h-1 _,' i ,1 ] n_;-'.'. ... -. , 1 W.2 ·-: ;....u t !. f J : I I L '--, i I t ' -·----' r.r-.7".:-L! i_u.1±1 ;-; ·-f--l,Q-1 '-l It rluT~,{~~':Yk~~u·11 :i.[l li-iJ..:t.Y.··t'iTlUTl~··-.,t~•c'(:.flltC· r . .iJ•• .. :J:t.:J:,r~d .. 1--,, :·, ~ ,-, j 1! :::0 l !J_r, LJ_j'"'l~~,,lffl-, I i-1~~ffl:-I :l h-J-P, Jlr:~; .111Trt<kM1~]::·.:!·l~L · ··-···;p:_:,! i:1 }.l i·~ .. I ,-L •...J ~ I •• !, · ~:~77Li-t1 .::-,-:-. t.L.:T• 1~criT"1 ttt~~~t~f1.t:::PH-l~H~~~~%!+tW%m.m;J.4~<~w.1..1.J.~t=wi, J... , 3•00--1 1 I~.;-_-:..:_-:--j_J ~j ti-l h ---~ : '--:: I ·' i.t i . _ , , I , . , I , 3 -· ..... . 1 !_t •-.... J. .. -\..:.1>:J'b:r--+-' 'ml ' ! I JI] 1_ 1 , '7 I ,-1-. --···1 ::i r""---..--. m Lr-i1::: '-~~; ,--•1 h 'c--=r-'--,t -i -· ·, .-1-;-: ~=d 1-1.1 · g. . 1 ·;-; :i· :·u:t, ; i r: · m:~~~~u~~~-~+----1""r:~.r.. :::, 4 I i ; : r ! . .'.I. • ·1-:· ;:i-. ~iiJi!!;.U.,:c.,:.-1..l...!J 1~~~ri ,r.-:-.,o,,,~j , c. I L-7-.., l j !.. ,_tl-l ; I • 32'f5l· I I • ...; I • I :7..! '-w:r,·.c.a,,...,11 2•45•1 1 -· .-:--·, L· • • ~~11rm ~......... -. · 1 •-i r ~r :-!1cLU-~-. -11 , ~ , . ··-~]~-., · :! i . -i I i ·; ; i L'.]'J !. _ !. , . r 1 , • ••• __ . . • • _ , • ·1.: , ,. County of San Diego Hydrology Manual Rainfall Isopluvials 100 Ye11r Rainfall Event-24 Hours [ ....... . loopluvtal (Inches) GPS COORDINATES: P24=4.8" P6/P24= 56% DPW ~-j rj-J -i-t I fi 1 i , ... ~rr-.·r 1 ·-!..!..! Ir:·· { 1.rr;-,.t L ~G.J.~ SaiiGI$ 1 .. ·----\~.. \\1."ll." .. '1:1 lll.-r,1<.t""'':i> I i -=-14N :::,.==._~=~-~-~• ['•;t.l[.:.r!,t.7 j ~;' ,-, l·q:; :•:_. !. -'3f'SO: I I I • • I ; I -,-• -: '· r-,--• -~~-,-+--,.. I I --.,( .,tf-i'T" H-'---'-.1 .. en . I t ..:.-,-; [~ 1..LL:;:' .....J. · 1·: C.,_ 1:-. ~ '-L-,--t,~J,Mffi-m"ICNttJll••"'"'°""".u.ms I l ~--.... -..- E ==:.,-~:=:-..=.::,.~_:.-~ --•INCAG m ::=.,:,~~-=----z s -l 3 0 3 Mlles N r--, -->. San Diego County Hydrology Manual Date: June 2003 Table 3-1 Section: Page: RUNOFF COEFFICIENTS FOR URBAN AREAS Land Use I Runoff Coefficient "C" Soil T~ee NRCS Elements Coun Elements % IlvlPER. A B Undisturbed Natural Terrain (Natural) Permanent Open Space 0* 0.20 0.25 Low Density Residential (LOR) Residential, 1.0 DU/A or less 10 0.27 0.32 Low Density Residential (LDR) Residential, 2.0 DU/A or less 20 0.34 0.38 Low Density Residential (LDR) Residential, 2.9 DU/ A or less 25 0.38 0.41 Medium Density Residential (MOR) Residential, 4.3 DU/A or less 30 0.41 0.45 Medium Density Residential (MOR) Residential, 7.3 DU/A or less 40 0.48 0.51 Medium Density Residential (MDR) Residential, 10.9 DU/A or less 45 0.52 0.54 Medium Density Residential (MOR) Residential, 14.5 DU/A or less 50 0.55 0.58 High Density Residential (HDR) Residential, 24.0 DU/A or less 65 0.66 0.67 High Density Residential (HDR) Residential, 43.0 DU/A or less 80 0.76 0.77 Commercial/Industrial (N. Com) Neighborhood Commercial 80 0.76 0.77 Commercial/Industrial (G. Com) General Commercial 85 0.80 0.80 Commercialt1ndustrial (O.P. Com) Office Professional/Commercial 90 0.83 0.84 Commercial/Industrial (Limited I.) Limited Industrial 90 0.83 0.84 Commercial/Industrial {General 1.) General Industrial 95 0.87 0.87 C 0.30 0.36 0.42 0.45 0.48 0.54 0.57 0.60 0.69 0.78 0.78 0.81 0.84 0.84 0.87 3 6 of26 D 0.35 0.41 0.46 0.49 0.52 0.57 0.60 0.63 0.71 0.79 0.79 0.82 0.85 0.85 0.87 *The values associated with 0% impervious may be used for direct calculation of the runoff coefficient as described in Section 3.1 .2 (representing the pe1vious runoff coefficient. Cp, for the soil type), or for areas that will remain undisturbed in perpetuity. Justification must be given that the area will remain natural forever (e.g., the area is located in Cleveland National Forest). DU/A"" dwelling units per acre NRCS ~ National Resources Conservation Service 3-6 )> -I -I )> () I s:: m z -I I\.) ...... • ) , \ ,, 0 ATTACHMENT 21 San Diego County Hydrology Manual Date: June 2003 Section: Page: ,., -' 5 of26 Where: C = 0.90 x (%Impervious)+ Cp x (1 -% Impervious) Cp = Pervious Coefficient Runoff Value for the soil type (shown in Table 3-1 as Undisturbed Natural Terrain/Pennanent Open Space, 0% Impervious). Soil type can be determined from the soil type map provided in Appendix A. The values in Table 3-1 are typical for most urban areas. However, if the basin contains rural or agricultural land use, parks, golf courses, or other types of nonurban land use that are expected to be permanent, the appropriate value should be selected based upon the soil and cover and approved by the local agency. 3-5 I ♦' Iii UJ LL ~ UJ (_) z ~ Cl) 5 w en ci:: ::, 0 {,) c:r: Lil ~ ~ 100I 1.5 I HF'J I I 1 ..,,, Ji, I ·~ I ✓l ::A 130 Cl) LU I-::, z 0 20 ~ z w :::?: i== s: 0 ...J I.I,_ 10 ~ ::s Ct: w eS ~ 0 EXAMPLE: Given: Watercourse Distance (D) = 70 Feet Slope (s) = 1.3% Runoff Coefficient (C) = 0.41 Overland Flow Time (T) = 9.5 Minutes T = 1.8 (1.1-C) V!5 3\fs SOURCE: Airport Drainage, Federal Aviation Administration, 1965 FIGURE Rational Formula -Overland Time of Flow Nomograph 3-3 I ► -I ~ () I ~ m z -I N ..... • ) J ; C ~E Feet 5000 4000 EQUATION Tc .. (1~t)0.385 Tc = Time of concentration (hours) L = Watercourse Distance (miles) .6.E = Change in elevation along 0 effective slope tine (See Rgure 3-S)(feet} .6.E 300-0 2000 1000 0 0 ' 500 '-' 400 '- 300 200 100 30 20 10 5 ,~ .;:~,,,. ~'& ' ' ' ' ' ' ' ' SOURCE: California Division of Highways (1941) and Kirpieh (1940) L Miles Feet '1 ' 3000 0.5 ' 2000 300 200 L ' Nomograph for Determination of ' ' ' ' ATTACHMENT 21 Tc ' Tc 50 40 30 20 18 16 14 12 10 9 8 1 6 5 4 3 FIGL"RE Time of Concentration (Tc) or Travel Time (Tt) for Natural watersheds ~ • Q) a. 0 in G) Q) b, 0 -;R. 0 20 18 16 14 12 10 9 8 7 6 5 4 3 2 1.8 1.6 1.4 1.2 1.0 0.9 0.8 0.7 0.6 - - 0.5 - 0.4 1 -+--n = .015--. 1 ___ 2% ~ n ~ .0175 ----______:;..:.::.. ___ ___J 2% • I !-- / H ~, -;j· ~ -1 I --- r---.... I I / r----I I ~ I t--. I /~ I ~ , I I ..... t,, _ ~ .s. Concrete Gutter I L_ I I -- __ a;- '-'--QJ) P; <::> .s ~7--- / ~ I i""'j _ I I ' r--..._ I I r-- I ' r--... I --, ..__ j r r--.._;' ::(::- Paved t ---. ,._____ v, j --------:-10, r ~ r----.. r----I J r--..~ '8r1J_s I ~ J J --,..... I I ------- .... v,,,.s I ...._r-!P-s I r---;..... ~"'"s ~ -i!!:.':...r-1_ I/ -....... v.,, I ~ if) cJ' i----.:: '1 f" .... ~~-... -1.t__, I ill r---.. ~ CY.._ r---.. I f:J --.......... (.<,'1' I -----...... l ~v"'".J Q0.,, ........... ~, J J s,---.........__ r--.. f.p_s ~ I K ... , , 01 r---... r----i;,"'"< I r-..... I r----...:-sr r---.. I ~-s. ---.......1 I '-I_ / ............... , I --......... I ~ .....____ I/"'"< f .....__ 'r--. , I ..... -P,s_ -' ✓ I/ ~/ I • ---........_ r----..._ r-... I I" ATTACHMENT 21 RESIDENTIAL STREET ONE SIDE ONLY . 7---v,__ I --.::__z__<, ·/:) -I ~ ~ I I ~ I J .............. / ~ I ....... ~ ........ j ~ I I Ir" I r---... I l I"-~ ,,.......__ ..... -' ..... r-.../ 1.t..rfff I c:,'<?J .._ I (lJ 1/ ....... "l.t__(IJ a?-r----$1 Q I SJ, r-... I L j I [/ I Q? ......_t-,. , I'--.. j I' '-..... ....... I ..... ~ ... 2 3 4 5 6 7 8 9 10 20 30 40 50 Discharge (C.F.S.} EXAMPLE: Given: Q = 10 S = 2.5% Chart gives: Depth= 0.4, Velocity = 4.4 f.p.s. SOURCE: San Diego County Department of Special District Seivices Design Manual FIGURE Gutter and Roadway Discharge -Velocity Chart ~ '{' 0 E Q) a. Q) .& .!: w CL 0 ....I U) 0.3 0.2 0.15 0.002 0.001 0.0009 0.0008 0.0007 0.0006 0.0005 0.0004 0.0003 C EQUATION: V = 1.49 R2J3 s ,;, n 02 0.3 4 5 6 7 8 9 10 20 GENERAL SOLUTION 0 > SOURCE: USDOT, FHWA, HDS-3 (1961) Manning's Equation Nomograph 20 2 1.0 0.9 0.8 0.7 0.6 0.5 ATTACHMENT 21 0.01 0.02 C 0.03 c Cl) ·o ~ 0 0.04 0 en en ~ ro.os I C) 0.06 :::> 0 a:: 0.07 0.08 0.09 0.10 0.2 0.3 0.4 • FIGURE ~ ! illi f1 6.0 I -5.0,-T'RJ'I N N--l rt-I [N,.IJ I ~ r,, ::GJ HttHmfll EQUATION mm ~11111111111! ~.: ~=:~~:~~tioo(lo) · -D = Duration (min) I .. ,,rm ~ I- I ''ir1iffiE.lffllB::: •m~m•--~ :~ -_: ~ :.· • • ..... ~m•- 'r' :x: __ .11 TI i .. -■ "' ·~o.s1 I I I I I 1111111 II I l'l'IUIIIIIIIIIIIIIIIIIII · · -•-. · ~ !•11 I I I I I I 11111111111111111111111111 ~ l!Ml!11111111111111~.c.·• ·-· ·-······ o.s1 I I I I I I I I 1111111111111 IIIIIIIIIIII I II II ll I I o.51 I I I I I I I I I I 11 -[> ""-'- " I ._1 I I jm --1"'. I~ "' 0.41111 1 1111111111111111111 11111111111 11111111111111111111111m1m1n 0.3 J---+--. 0 ~ l' ~ (0 I Q. -6.0 '2. 5.5 i fnll s.o g 4.5 I 4.0 CD 3.5-.!!!. 3.0 2.5 2.0 --r-i--1-•t--+---+ -+-!-+-+·· 1--1----(;4,•+-➔· 0.2 1.5 ~ ±J rffll·· t ll LL l: 0.1 , 5 6 7 8 9 10 15 20 30 40 50 2 3 4 ··1·11~ 5 6 Minutes Duration Hours lntenslty~Duratlon Design Chart ~ Template ATTACHMENT 21 Directions for Applleatlon: (1) From precipitation maps determine 6 hr and 24 hr amounts for the selected frequency. These maps are Included in the County Hydrology Manual (10, 50, and 100 yr maps Included in the Design and Procedure Manual). (2) Adjust 6 hr precipitation (If necessary) so that it is within the range of 45% to 65% of the 24 hr precipitation (not applicapfe to Desert). (3) Plot 6 hr precipitation on the right side of the chart. (4) Draw a line through the point parallel to the plotted lines. (5) This line is the intensity-duration curve for the location being analyzed. Application Form: {a) Selected frequency _JQQ_ year (b) Pe= 2.7 in. P24 = 4.8 ~ = 56 %(2) --' --'P24 -- (c) Adjusted P6<2l = __ in. (d) tx = _5_ min. (e) I = _?.1_!_ in./hr. Note: This chart replaces the Intensity-Duration-Frequency curves used since 1965. P6 1 1.5 : 2 ' 2.5 3 : 3.5 1 4 . 4.5 5 s:s 6 ou;atiori: i' I I I . ;-I I : I l I TT j i I .... ~:_J._ ... _.Al~. :?_ ,§l_s; __ -_--'_~ns __ .59 J_,!I_Oli !!,2_,2 j 0.54_, I 1.86;_ 1_ 3.17: 14 . .49: 15.81 ...... 7. 2.12 ,3.18, 4.24 j 5.30 l 6.3& 7.42 i ll.48 i 9.54 : 10.60: 11.66, 12.72 .... 10 __ 1.68_&S3.l?.~71~-21:s.os15.90, 67~17.58;_8.4,:', ~,27_:1/'.UI 1_5 .. ,,3-9 :1,95Li!-5!1,j ~,_24.;?:894~·54[§.J!l 1 ~·131;~,~~-Jl_<i\J,!8 __ 20 __ t.08 , 1,82L2 1?1 2,6!!_1?,23: (l:!.7!.1,31 __ , 4_.!!~+s,;i!I_, 5,§l~i §...4!> _ 25 _ 0.93, ; _I_A9;J.~7 L?:~tl_2.~ 4 :l.2(i :Ji'~.: 4.20 i 4,67.; __ 5.13 : 5J3(} _ .30 .. 9·~ 11,24(.166\2.07 ;2_4~i?•~i :3,J:? ! 3,73; 415 ,_456: 4.98 . 4.9 __ o_,fl!l I 1.03\ 1.3fl ).172; 2.07; 2.41 i 278 j 3.1{) [ 3,45 : 3.79 :. 4.13 _so .o,so_,0.9Cl;;U~i 1_.49, t.79.;2.09! 2.391:i_,i,:~-' 2.98, 3.2s: 3 .. ss . so os:i ;0B0: 100, 1,33, 1.59;1.ae: 2.12; 2.39_ 2.ss 2.921 3_1_s I· •• 90 .'J..~1 .... illJ1_;_08.2i 1,_0?(1.23;L431163.i 1_.84;2,01,.2,25\245_ _1~ 0.34 ,o.51 10,68(0,Bs_; 1.0011.191L361.1,53. 1-70: 1,8.7 j 204_ _ -~s_o _Q.ge ;o,4-:,ui,~1o.73_;0,011:1,93j u~; 1,~; 1,41: 1,s21_ 1.16 .1.~ _().:lll.;OJ.9!0·52_1 o,~5;1l-~,O.91, 1,°:f+ 1,18 1 L31 , t_,4~ p 57 J~ J~_riit~:;1z:xt~'.:t~:~g: g:% J i::t: 6:~t:t;,t:-}J~ 360 0.17 '0.2Si0.33,0.42'0.50 0.58 0.67 0.15,0.&1: 0.~2I 1.00 ~~: I . . . • ' C ATTACHMENT 21 San Diego County Hydrology Manual Date: June 2003 Section: Page: 3 20 of26 3.2 DEVELOPING INPUT DAT A FOR THE RATIONAL METHOD This section describes the development of the necessary data to perfonn RM calculations. Section 3 .3 describes the RM calculation process. Input data for calculating peak flows and Tc's with the RM should be developed as follows: I. On a topographic base map, outline the overall drainage area boundary, showing adjacent drains, existing and proposed drains, and overland flow paths. ') ,,. .. 3. Verify the accuracy of the drainage map in the field. Divide the drainage area into subareas by locating significant points of interest. These divisions should be based on topography, soil type, and land use. Ensure that an appropriate first subarea is delineated. For natural areas, the first subarea flow path length should be less than or equal to 4,000 feet plus the overland flow length (Table 3-2). For developed areas, the initial subarea flow path length should be consistent with Table 3-2. The topography and slope within the initial subarea should be generally uniform. 4. Working from upstream to downstream, assign a number representing each subarea in the drainage system to each point of interest. Figure 3-8 provides guidelines for node numbers for geographic information system (GIS)-based studies. 5. Measure each subarea in the drainage area to determine its size in acres (A). 6. Determine the length and effective slope of the flow path in each subarea. 7. Identify the soil type for each subarea. 3-20 • I • Study Area SC .. ,··1 I , ~ 17 l.. I / \ /' l-· Study Area LA 0 Define Study Areas {Two-Letter ID) 0 Define Maps {or Subregions on Region Basis) © Define Model Subareas on Map Basis , .... "" ' , 1.,."'° I ! ,' ....... -ot,. ... ' . . 0 Define Major Flowpaths in Study Area 0 Define Regions on Study Area Basis Subarea ID= (LA010112) Node# l Map#----·-- Region# st,dy Anoa (ID) • l l l . © Define Model Nodes (Intersection of Subarea Boundaries with Flowpath Lines) GIS/Hydrologic Model Data Base Linkage Setup: Nodes, Subareas, Links LA 01 01 03 0 Number Nodes ~ ~~_J )> -i ~ 0 I s:: m z -i N ....... -.J ' 1 \, , San Diego County Hydrology Manual Date: June 2003 0 Section: Page: ATTACHMENT 21 3 22of26 8. Determine the runoff coefficient (C) for each subarea based on Table 3-1. If the subarea contains more than one type of development classification, use a proportionate average for C. In determining C for the subarea, use future land use taken from the applicable community plan, Multiple Species Conservation Plan, National Forest land use plan, etc. 9. Calculate the CA value for the subarea. I 0. Calculate the L(CA) value(s) for the subareas upstream of the point(s) of interest. 11. Detennine P6 and P24 for the study using the isopluvial maps provided in Appendix B. If necessary, adjust the value for P6 to be within 45% to 65% of the value for P24. See Section 3.3 for a description of the RM calculation process. 3.3 PERFORMING RATIONAL METHOD CALCULATIONS This section describes the RM calculation process. Using the input data, calculation of peak flows and Tc's should be performed as follows: l. Determine T; for the first subarea. Use Table 3-2 or Figure 3-3 as discussed in Section 3.1.4. If the watershed is natural, the travel time to the downstream end of the first subarea can be added to Ti to obtain the Tc. Refer to paragraph 3.1.4.2 (a). 2. Determine I for the subarea using Figure 3-1. If Ti was less than 5 minutes, use the 5 minute time to determine intensity for calculating the flow. 3. Calculate the peak discharge flow rate for the subarea, where Qp = L(CA) I. In case that the downstream flow rate is less than the upstream flow rate, due to the long travel time that is not offset by the additional subarea runoff, use the upstream peak flow for design purposes until downstream flows increase again. 3-22 San Diego County Hydrology Manual Date: Jun.: 2003 4. Estimate the Ti to the next point of interest. 5. Add the T1 to the previous Tc to obtain a new Tc. Section: Page: ATTACHMENT 21 3 23 of26 6. Continue with step 2, above, until the final point of interest is reached. 'Jote: The MRM should be used to calculate the peak discharge when there is a junction from independent subareas into the drainage system. 3.4 MODIFIED RATIONAL METHOD (FOR JUNCTION ANALYSIS) The purpose of this section is to describe the steps necessary to develop a hydrology report for a small watershed using the MRM. It is necessary to use the MRM if the watershed contains junctions of independent drainage systems. The process is based on the design manuals of the City/County of San Diego. The general process description for using this method, including an example of the application of this method, is described below. The engineer should only use the MRM for drainage areas up to approximately I square mile in size. If the watershed will significantly exceed 1 square mile then the NRCS method described in Section 4 should be used. The engineer may choose to use either the RM or the MRM for calculations for up to an approximately I-square-mile area and then transition the study to the NRCS method for additional downstream areas that exceed approximately I square mile. The transition process is described in Section 4. 3.4.1 Modified Rational Method General Process Description The general process for the MRl\1 differs from the RM only when a junction of independent drainage systems is reached. The peak Q. Tc, and I for each of the independent drainage systems at the point of the junction are calculated by the RM. The independent drainage systems are then combined using the MRM procedure described below. The peak Q, Tc, and I for each of the independent drainage systems at the point of the junction must be calculated prior to using the MRM procedure to combine the independent drainage systems, as these 3-23 San Diego County Hydrology Manual Date: June 2003 0 Section: Page: ATTACHMENT 21 3 24 of26 values will be used for the MRM calculations. After the independent drainage systems have been combined, RM calculations are continued to the next point of interest. 3.4.2 Procedure for Combining Independent Drainage Systems at a Junction Calculate the peak Q, Tc, and I for each of the independent drainage systems at the point of the junction. These values will be used for the MRM calculations. At the junction of two or more independent drainage systems, the respective peak flows are combined to obtain the maximum flow out of the junction at Tc. Based on the approximation that total runoff increases directly in proportion to time, a general equation may be written to determine the maximum Q and its corresponding Tc using the peak Q, Tc, and I for each of the independent drainage systems at the point immediately before the junction. The general equation requires that contributing Q's be numbered in order of increasing Tc. Let Q1, T1, and 11 correspond to the tributary area with the shortest Tc. Likewise, let Q2, T2, and Ii correspond to the tributary area with the next longer Tc; Q3, T3, and h correspond to the tributary area with the next longer Tc; and so on. When only two independent drainage systems are combined, leave Q3, T3, and h out of the equation. Combine the independent drainage systems using the junction equation below: Junction Equation: Ti< T2 < T3 3-24 4 I I • ATTACHMENT 21 San Diego County Hydrology Manual Date: June 2003 Section: Page: 3 25 of26 Calculate Qn, Qn, and Qr,. Select the largest Q and use the Tc associated with that Q for further calculations (see the three Notes for options). If the largest calculated Q's are equal (e.g., Oi-1 = Qn > QT3), use the shorter of the Tc's associated with that Q. This equation may be expanded for a junction of more than three independent drainage systems using the same concept. The concept is that when Q from a selected subarea ( e.g., Q2) is combined with Q from another subarea with a shorter T0 (e.g., Qi), the Q from the subarea with the sh011er Tc is reduced by the ratio of the I's (hil1); and when Q from a selected subarea (e.g., Q2) is combined with Q from another subarea with a longer Tc (e.g .• Q3), the Q from the suharea with the longer Tc is reduced by the ratio of the Tc's (T)Ti). Note #1: At a junction of two independent drainage systems that have the same Tc, the tributary flows may be added to obtain the Q~. This can be verified by using the junction equation above. Let Q3, T3, and 13 = 0. When Tr and T2 are the same, 11 and hare also the same, and T1/T2 and h/1 1 = I. T1/T2 and fi/1 1 are cancelled from the equations. At this point, QT1 = QT2 = Qi + Q2. Note #2: In the upstream part of a watershed, a conservative computation is acceptable. When the times of concentration (Tc's) are relatively close in magnitude (within 10%), use the shorter Tc for the intensity and the equation Q = L(CA)l. Note #3:. An optional method of determining the Tc is to use the equation Tc= [(L (CA)7.44 P6)/Q] 155 This equation is from Q = I(CA)I = I(CA)(7.44 Ptlfc645 ) and solving for Tc. The advantage in this option is that the Tc is consistent with the peak flow Q, and avoids inappropriate fluctuation in downstream flows in some cases. 3-25 C 0 I '' • ATTACHMENT 21 STORMTRAP® TYPICAL SPECIFICATIONS FOR "SINGLE TRAP" SYSTEM STORMTRAP INSTALLATION SPECIFICATION 1 STORMTRAP MODULES SHALL BE MQ.NUFACTUREO ACCORDING TO SHOP DRAWINGS APPROVED BY THE INSTALLING CONTRACTOR AND ENGINEER. THE SHOP DAAWltGS SHALL INDICATE SIZE AND LOCATION Of ROOF OPENINGS AND INLET/OUTLET PIPE OPENINGS. 2 STORMTRAP SHAU. BE INSTALLED IN ACCORDANCE WITH ASTM C891-09, STANDARD PRACTICE FOR "4$TALLATION OF UNDERGROUND PRE-CAST CONCRETE UTILITY STRUCTURES THE FOLLOWING ADDITIONS AN DIOR EXCEPTIONS SHALL APPLY A SPECIFICATIONS ON THE ENGINEER'S DRAWINGS SHALL TAKE PRECEDENCE B STORMTRAP MODULES SHALL BE PLACED ON LEVEL FOUNDATION (SEE SHEET 3.1) WITH A 1'-0" OVERHANG ON AU.SIDES THAT SHALL BE POURED lN PLACE BY INSTALLING CONTRACTOR C THE STOAMTRAP MODULES SHALL BE PLACED SUCH THAT THE MAXIMUM SPACE BETWEEN ADJACENT MODULES DOES NOT EXCEED 3;4'. IF THE SPACE EXCEEDS 3,'4' THE MODULES SHALL BE RESET WITH APPAOPRIA TE ADJUSTMENT MA.DE TO LINE AND GRADE TO BRING THE SPACE INTO SPECIFICATON D. THE PER METER HO RIZO NT Al JOINT OF THE STORMTRAP MOO LILES SHALL BE SEALED TO THE FOLtJDATION WITH PREFORMED MASTIC JOINT SEALER ACCORDING TO ASH..t C891-09. 8.8 AND 8.12. SEE DETAIL "A". E ALL EXTERIOR JOINTS BETWEEN ADJACENT STORMTRAP MODULES SHALL BE SEALED WITH PRE-FORMED, COLD-APPLIED, SELF-ADHERING ELASTOMERIC RESIN BONDED TO A WOVEN HIGHLY PUNCTURE RES,STANT POLYMER WRAP CONFORMING TO ASTM C891- 09AND SHALL BE0'-8" INTEGRATED PRIMER SEALANT AS M'PROVED BY STOAMTRAP THE ADHEStiE EXTERK>R JOINT WRAP SHALL BE INSTALLED ACCORDING TO THE FOLLOWING INSTALLATION INSTRUCTIONS: 1. USE A BRUSH DA WET CLOTH TO THOROUGHLY CLEAN THE OUTSIDE SURFACE AT THE POINT WHERE THE JOINT WRAP IS TO BE APPLIED 2 A RELEASE PAPER PROTECTS THE ADHESNE SIDE OF THE JOINT WRAP. PtACE THE ADHESIVE TAPE (BUTYL SIDE DOWN) AROUND THE SIBUCTURE, REMOVING THE REL.EASE PAPER AS YOU GO PRESS THE JOINT WRAP FIRMLY AGAINST THE STOAMTRAP MODULE SURFACE WHEN APPLYING F. THE FILL PLACED AROUND THE STORMTRAP UNITS MUST BE DEPOSITED ON BOTH SIDES AT THE SArvE TIME AND TO APPROXIMATELY THE SAME ELEVATION. AT NO TIME SHALL THE FLL BEHIND ONE SIDE WALL EE MORE THAN 2'-0" HIGHER THAN THE ALL ON THE OPPOSITE SIDE. BACKFILL SHALL BE COMPACTED TO 95';\S STANDARD PROCTOR DENSITY OR OTHERWISE SPECIFIED BY ENGINEER. CARE SHALL BE TAKEN TO PREVENT ANY WEDGING ACTION AGAINST THE STRUCTURE, ANO ALL SLOPES BOUNDING OR WITHIN THE AREA TO BE BACKFILLED MUST BE STEPPED OR SERRATED TO PREVENT WEDGE ACTION. (REFERENCE ARTICLE 502.10 l.0.0.T. S S.R.B.C.J CARE SHALL ALSO BE TAKEN AS NOT TO DISRUPT THE JOINT WRAP FROM THE JOINT DURING THE MCKFLL PROCESS BACKFILL W\TEAIA.L SHALL BE CLEAN, CRUSHED, ANGULAR No.5 l,AASHTO M431 AGGREGATE a EXTERIORWALL FOUNDATION OF STORMTRAP (/) JOINT TAPE APPLIED OUND THE PERIMErER OFTHE SYSTEM ONLY DETAIL "A" JOINT TAPE INSTALLATION JOINT WRAP (SEE NOTE 2E) ALLOWABLE MAX GRADE = TBD ALLOWABLE MIN. GRADE = TBD IF SPECIFIED BY ENGINEER GEOFABRIC PROVIDED AND INSTALLED BY CONTRACTOR STEPPED OR SERRATED AND APPLICABLE OSHA REQUIREMENTS SEE NOTE2F ~-------------.--+------½---ll'SIDE HEIGHT ELEVATION= TBD 5'-C/' SINGLErRAP SEE DErAIL "A" "'l--'---'-4-------------L-,-J,---'1----SYSTEM INVERT= TBD 8' CONT REINFORCED CONCRErE FOUNDATION FOR STORMTPAP SYSTEM SEE SHEEr 3 1 FOR DEr AILS SEE SHEET 31 . FOR DErAILS 1'-Cl'MIN. 'ovERHANG 5'-0" SINGLETRAP STORMTRAP SPECIFICATION 1. TOTAL COVER: MN. 1.08 MAX. 10.00' CONSULT STORMTRAP FOR ADDITIONAL COVER OPTONS 2 CONCRETE CHAMBER DESIGNED FOR AASHTO HS-20 WHEEL LOADING. MIN. SOIL PRESSURE 3,000 PSF 3. ALL DIMENSIONS ANO SOIL CONDITIONS, INCLUDING BUT NOT LIMITED TO GROUNDW"ATER AND SOIL BEARING CAPACITY ARE TO BE VERFEO IN THE FIELD BY OTHERS PRIOR TO STORMTRAP INSTALLATION 4 FOR SIBUCTUAAL CALCULATIONS THE WATER TABLE IS ASSUMED TO BE BELOW THE SYSTEM INVERT, IF DIFFERENT THAN ASSUMED, CONTACT STORMTRAP 5 FOR STRUCTURAL CALCULATIONS THE SOIL DENSITY IS ASSUMED TO BE 120 PCF 6. FOR FLOT AT JON CALCULATIONS THE WATER TABLE IS ASSUMED TO BE BELOW THE SYSTEM INVERT. IF DIFFERENT THAN ASSUMED. CONTACT STOAMTRAP 7 STORMTRAP IS NOT WATERTIGHT. CONT ACT STORMTAAP FOR WATERTIGHT OPTIONS. WATERTIGHT APPLICATION TO BE PROVIDED BY OTHERS AH ufOR STRUCTUAALAND FLOTAT!ON CALCULATIONS THE WATER TABLE IS ASSUMED TO BE BELOW THE SYSTEM INVERT, IF DIFFERENT THAN ASSUMED CONTACT STORMTRAP ... .~ "'·2495 WEs1BuNcA~)w.1w MORR5 IL 60450 P: 815-941-4663 F:815-416-1100 ENGINEER INFORMATION- BHA ENGINEERS 5115AVENIDA ENCINAS CARLSBAD. CA 92008 Phone: (760) 931-8700 Fax: (760) 931-7780 PROJECT INFORMATION· BREAKERS VIEW CARLSBAD,CA ( CURRENT ISSUE DATE" I 05-APR-2016 rPPROVEDBY ISSUED FOR: I PRELIMINARY REV· DATE. DESC SCALE: SHEET TITLE SINGLETAAP INSTALLATION SPECIFICATIONS SHEET NUMBER. 1.0 BY· QTY. 0 0 0 0 0 1 2 4 1 I BILL OF MATERIALS PART NO. DESCRIPTION TYPEI 5'-0" SINGLETAAP TYPE I TYPEII 5'-0' SINGLETRAP TYPE II TYPE HI 5'--0" SINGLETAAP TYPE Ill TYPE IV 5'-0' SlNG..ETRAP TYPE IV TYPEV 5-0' SINGLETRAP TYPE V TYPE VIP 5--0" SINGLETRAP TYPE VIP END PANEL 6' THICK ENO PANEL JOINT TAPE JOINT TAPE-14.5' PER ROLL JOINTWAAP JOINT WRAP -150 PEA ROLL ~ I WEIG-IT 13555 8685 16025 9920 9920 18495 2904 CONCRETE SLAB 1'·0' (TYP) SEE SHEET 2 1 DIMENSION OF STORMTRAP SYSTEM AU.OW FCR A 3/~' GAP BETWEEN EACH UNIT 2. AU. DWENSIONS TO BE VERIFIED IN THE FIELD BY OTHERS. 3. SEE SHEET 2 FCR INSTALI.ATION SPECIFICATIONS -=-r~--------------1 15•0· I I I I I I I I I I I T J,• I ., LAYOUT DETAIL DESIGN CRITERIA INSIDE HEIGHT ELEVATION= TBD ALLOWABLE MIN GRADE = TBD ALLOWABLE MAX GRADE = TBD SYSTEM INVERT = TBD STORMTAAP VOLlNE = 418 50 C.F. i 0.02 A.F ~ATT~ ! 2-495 WEST BUNGALOW RD N !f'aW"i-111-~~f •. f:81;.;11,.1100 I ENGINEER INFORMATION BHA ENGINEERS 5115 AVENIDA ENCINAS CARLSBAD, CA 92008 Phone: (760) 931-8700 Fax: (760) 931-7780 PROJECT INFORM.ti. TION BREAKERS VIEW CARLSBAo,cO CURRENT ISSUE DATE: I 05-APR-2016 APPROVED SY I ISSUED FOR I PRELIMINARY REV. DATE OESC BY ~ -SCALE: SHEET TITLE· LAYOUT DETAIL SHEET NUMBER 3.0 .. ,. I I I ,,_ ___________ 17 ----------- NOTES 1. DIMENSION OF FOUNDATION MUST HAVE 1'-0' OVERHANG BEYOND EXTERNAL FACE OF UNITS 2. DIMENSION OF STORMTRAP SYSTEM ALLOW FOR A 3/4' GAP BETWEEN EACH UNIT 3. ALL DIMENSIONS TO BE VERIFIED IN THE FIELD BY OTHERS 4. SEE SHEET 2 FOR INSTALLATION SPECIFICATIONS. CONCRETE EOUNDAIIQN PLAN TOP OF FOUNDATION~~--'"-----~ s·-~ ~ J 3' I '-----r-CLR DETAIL "B' #5 BARS ,g: 10· o c --IN BOTH DIRECTIONS STORM TRAP FOUNDATION NOTES. 1 4.000 p.s.1. 1g) 28 DAYS, 5%-8% ENTRAII\EO A!R, 4'' MAX SLUMP 2 NET ALLOWABLE SOIL PRESSURE GREATER THAN OR EQUAL TO 2,000 p s.f 3 SOIL CONDITIONS TO BE VERIFIED ON SITE BY OTHERS 4 1 '-0' OVERHAI\G AROUND OUTSIDE OF SYSTEM 5. REBAR: ASTM A-615 GRADE 60. BLACK BAR .I. --., ATT,f<.~ 2495 WEs1BuNGALow rw MORR~ 11604.50 P:8I5-941-4663 F:815-416-1100 ENGINEER !NFORM"-TION· BHA ENGINEERS 5115 AVENIDA ENCINAS CARLSBAD, CA 92006 Phone: (760) 931-8700 Fax (760) 931-7760 PROJECT lt-E"OAMATION BREAKERS VIEW CARLSBAD, CA CURRENT ISSUE DATE 05-APR-2016 APPROVED BY: ISSUED FOR: PRELIMINARY REV: DATE: DESC SCALE SHEET TITLE CONCRETE FOUNDATION PLAN SHEET NUMBER- 3.1 J BY 7 COAST GEOTECHNICAL CONSUL TING ENGfNEERS AND GEOLOGISTS May 16, 2018 Michael Jason Ianni 23 3 7 Catalina Ave Vista, CA 92084 Subject: GEOTECHNICAL UPDATE REPORT 3648 Carlsbad Boulevard Carlsbad, California References: REVISED CITY OF CARLSBAD RESPONSE Proposed Twin Home Development 3648 Carlsbad Boulevard Carlsbad, California Prepared by Coast Geotechnical Dated July 25, 2016 PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Twin Home Development 3648 Carlsbad Boulevard Carlsbad, California Prepared by Coast Geotechnical Dated February 11, 2016 Dear Mr. Ianni: ATTACHMENT 22 This report presents the results of our review of the current architectural plans, previous geotechnical reports and data, and our site review. The purpose of this report is to update the Preliminary Geotechnical Report dated February 11, 2016 and evaluate if any additional recommendations are necessary based on the current plans. P.O. BOX 230163 * ENCINITAS, CALIFORNIA 92023 (858) 755-8622 C Coast Geotechoical SITE CONDITIONS 0 ATTACHMENT 22 May 16, 2018 W.O. P-6541115 Page 2 of3 The subject property is located at 3648 Carlsbad Boulevard, north of Juniper A venue, along the east side of Carlsbad Boulevard, in the city of Carlsbad. The subject property is a relatively level rectangular residential lot. The site includes a single story residence with an attached garage. Access to the rear of the site is via an alley which enters from Juniper A venue. The property is bounded along the north, south and east by developed residential lots. PROPOSED DEVELOPMENT Current architectural plans for the development of the site were prepared by Transpacific Architects. The project will include demolition of the existing structure and the construction of a new two (2) unit twin home structure. The structure will be constructed at or slightly below existing grade. The current plans suggest only minor changes have been made to the concept design addressed in the Preliminary Geotechnical Report. GEOLOGIC CONDffiONS The subject property is located in the Coastal Plains Physiographic Province of San Diego. The property is underlain at relatively shallow depths by Pleistocene terrace deposits which have recently been re-classified as Old Paralic Deposits. The paralic deposits are underlain at depth by Eocene-age sedimentary rocks which have commonly been designated as the Santiago Formation on published geologic maps. The terrace deposits are covered by thin soil deposits and, in part, by minor fill deposits. Coast Geotechnical ATTACHMENT 22 May 16, 2018 W.O. P-6541115 Page 3 of3 CONCLUSIONS AND RECOMMENDATIONS I) Based on a site review, no significant changes to the site from a geotechnical viewpoint were observed. 2) The recommendations presented in the Preliminary Geotechnical Report remain applicable and should be implemented during the design and construction phases. 3) The supplemental recommendations presented in our City of Carlsbad Response including subsurface infiltration cutoff walls and Permeable Paver section should be implemented during the design and construction phases. 4) A copy of the final plans should be reviewed by this office prior to the initiation of construction. 5) All of the recommendations in the Preliminary Geotechnical Report and supplemental reports which are not superceded by this report remain applicable and should be implemented during the design and construction phases. If you have any questions, please do not hesitate to contact us at (858) 755-8622. This opportunity to be of service is greatly appreciated. Respectfully submitted, COAST GEOTECHNI ,., " 1• C CER ,~,:::o ' • GINf.:.ERl Engineering Geolo ~ 7o2 · ghanet. P. · cal Engineer C 0 COAST GEOTECHNICAL CONSULTING ENGINEERS AND GEOLOGISTS February 11, 2016 Marc Kovens 18 Via Burrone Newport Coast, CA 92657 RE: PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Twin Home Development 3648 Carlsbad Boulevard Carlsbad, California Dear Mr. Kovens: ATTACHMENT 22 In response to your request and in accordance with our Proposal and Agreement dated November 23, 2015 we have performed a preliminary geotechnical investigation on the subject site for the proposed twin home development. The findings of the investigation, laboratory test results and recommendations for foundation design are presented in this report. From a geologic and soils engineering point of view, it is our opinion that the site is suitable for the proposed development, provided the recommendations in this report are implemented during the design and construction phases. However, remedial grading will be necessary for proposed footings and slabs. Additional recommendations may be necessary based on our review of preliminary development plans. If you have any questions, please do not hesitate to contact us at (858) 755-8622. This opportunity to be of service is appreciated. Respectfully submitted, COAST GEOTECHNICAL Mark Burwell, C.E.G. Engineering Geologist Vithaya Singhanet, P .E. Geotechnical Engineer 779 ACADEMY DRIVE * SOLANA BEACH, CALIFORNIA 92075 (858) 755-8622 * FAX (858) 755-9126 ATTACHMENT 22 PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Twin Home Development 3648 Carlsbad Boulevard Carlsbad, California Prepared For: MarcKovens 18 Via Burrone Newport Coast, CA 92657 February 11, 2016 W.O. P-6541115 Prepared By: COAST GEOTECHNICAL 779 Academy Drive Solana Beach, California 92075 VICINITY MAP INTRODUCTION C SITE CONDITIONS PROPOSED DEVELOPMENT SITE INVESTIGATION LABORATORY TESTING GEOLOGIC CONDITIONS CONCLUSIONS RECOMMENDATIONS TABLE OF CONTENTS 0 ATTACHMENT 22 4 5 5 5 6 6 8 11 11 A. REMOV ALS/RECOMPACTION 11 B. TEMPORARY SLOPES/EXCAVATION CHARACTERISTICS 12 C. FOUNDATIONS 13 D. SULFATE CONTENT 14 E. SLABS ON GRADE (INTERIOR AND EXTERIOR) 14 F. LATERAL RESISTANCE 15 G. RETAINING WALLS 15 H. DYNAMIC (SEISMIC) LATERAL EARTH PRESSURES 16 I. SETTLEMENT CHARACTERISTICS 17 J. SEISMIC CONSIDERATIONS 17 K. SEISMIC GROUND MOTION DESIGN PARAMETERS 18 L. PRELIMINARY PAVEMENT DESIGN 19 M. UTILITY TRENCH 19 N. DRAINAGE 20 0. GEOTECHNICAL OBSERVATIONS 20 P. PLAN REVIEW 21 LIMITATIONS REFERENCES APPENDIX A APPENDIXB APPENDIXC APPENDICES LABORATORY TEST RESULTS EXPLORATORY BORING LOGS CONCEPT SITE PLAN REGIONAL FAULT MAP SEISMIC DESIGN PARAMETERS DESIGN RESPONSE SPECTRUM GRADING GUIDELINES 21 23 Data use subject to license. © 2004 Delorme. Tope USA® 5.o. www.delorme.com VICINITY MAP 5.0 Scale 1 : 9,600 'f om ,! ,omno ~: -~_I 1 .. = 800_0 ft Data Zoom 14-0 Coast Geotechnical INTRODUCTION ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Pages This report presents the results of our geotechnical investigation on the subject property. The purpose of this study is to evaluate the nature and characteristics of the earth materials underlying the property, the engineering properties of the surficial deposits and their influence on the proposed twin home development. SITE CONDITIONS The subject property is located north of Juniper A venue, along the east side of Carlsbad Boulevard, in the city of Carlsbad. The subject property is a relatively level rectangular residential lot. The site includes a single story residence with an attached garage. Access to the rear of the site is via an alley which enters from Juniper A venue. The property is bounded along the north, south and east by developed residential lots. Vegetation includes grass, shrubs and a few trees. Drainage is generally by sheet flow to the east. PROPOSED DEVELOPMENT Concept plans for the development of the site were prepared by Transpacific Architects. It is our understanding that the project will include demolition of the existing structure and the construction of a new two (2) unit twin home structure. The structure will be constructed slightly below existing Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page6 grade. It is anticipated that excavation of approximately 1. 0 vertical feet will be necessary to achieve pad grade. SITE INVESTIGATION Two (2) exploratory borings were drilled to a maximum depth of20 feet with a tri-pod hollow-stem drill rig. Earth materials encountered were visually classified and logged by our field engineering geologist. Standard penetration tests (SPT) were performed in the hollow-stem borings. Undisturbed, representative samples of earth materials were obtained at selected intervals. Samples were obtained by driving a thin walled steel sampler into the desired strata. The samples are retained in brass rings of 2.5 inches outside diameter and 1.0 inches in height. The central portion of the sample is retained in close fitting, waterproof containers and transported to our laboratory for testing and analysis. LABORATORY TESTING Classification The field classification was verified through laboratory examination, in accordance with the Unified Soil Classification System. The final classification is shown on the enclosed Exploratory Logs. Moisture/Density The field moisture content and dry unit weight were determined for each of the undisturbed soil C 0 Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page7 samples. This information is useful in providing a gross picture of the soil consistency or variation among exploratory excavations. The dry unit weight was determined in pounds per cubic foot. The field moisture content was determined as a percentage of the dry unit weight. Both are shown on the enclosed Laboratory Tests Results and Exploratory Logs. Maximum Dry: Density and Optimum Moisture Content The maximum dry density and optimum moisture content were determined for selected samples of earth materials taken from the site. The laboratory standard tests were in accordance with ASTM D-1557-91. The results of the tests are presented in the Laboratory Test Results. Shear Test Shear tests were performed in a strain-control type direct shear machine. The rate of deformation was approximately 0.025 inches per minute. Each sample was sheared under varying confining loads in order to determine the Coulomb shear strength parameters, cohesion and angle of internal friction. Samples were tested in a saturated condition. The results are presented in the Laboratory Test Results. Sulfate Test A sulfate test was performed on a selected sample in accordance with California Test Method (CTM) 417. The results are presented in the Lab Test Results. Coast Geotechnical GEOLOGIC CONDITIONS ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page8 The subject property is located in the Coastal Plains Physiographic Province of San Diego. The property is underlain at relatively shallow depths by Pleistocene terrace deposits. The terrace deposits are underlain at depth by Eocene-age sedimentary rocks which have commonly been designated as the Santiago Formation on published geologic maps. The terrace deposits are covered by thin soil deposits and, in part, by minor fill deposits. A brief description of the earth materials encountered on the site follows. Artificial Fill (at) No evidence of significant fill deposits were observed on the site. However, minor fill deposits, up to approximately 1.0 foot, are present along the perimeter of the residence. The fill is composed of locally derived silty, fine and medium-grained sand. The rear parking area is covered by approximately 4.0 inches of gravel. Soil (Os) Approximately 8.0 inches of soil was encountered in the exploratory borings. The soil is composed of brown silty fine and medium-grained sand. The soil is generally slightly moist and loose. The contact with the underlying terrace deposits is gradational. C Coast Geotechnical Terrace Deposits (Ot) 0 ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 9 Underlying the surficial materials, poorly consolidated Pleistocene terrace deposits are present. The terrace deposits are composed of tan to reddish brown, fine and medium-grained sand and are generally moist to very moist and weathered in the upper 2.0 to 3. 0 feet. Below the weathered zone, the terrace deposits are in a medium dense to dense condition. The terrace deposits generally exhibit little or no cohesion. Regionally, the Pleistocene sands are considered flat-lying and are underlain at depth by Eocene-age sedimentary rock units. Medium-dense to dense terrace deposits are considered suitable for the support of foundations and fills. Expansive Soil Based on our experience in the area and previous laboratory testing of selected samples, the fill deposits, residual soil and Pleistocene sands reflect an expansion potential in the very low range. Groundwater No groundwater was observed to the depth explored. However, it should be noted that seepage problems can develop after completion of construction. These seepage problems most often result from drainage alterations, landscaping and over-irrigation. In the event that seepage or saturated ground does occur, it has been our experience that they are most effectively handled on an individual basis. Coast Geotechnical Tectonic Setting ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 10 The site is located within the seismically active southern California region which is generally characterized by northwest trending Quaternary-age fault zones. Several of these fault zones and fault segments are classified as active by the California Division of Mines and Geology (Alquist- Priolo Earthquake Fault Zoning Act). Based on a review of published geologic maps, no known faults transverse the site. The nearest active fault is the offshore Rose Canyon Fault Zone located approximately 4.3 miles west of the site. It should be noted that the Rose Canyon Fault is not a continuous, well-defined feature but rather a zone of right stepping en echelon faults. The complex series of faults has been referred to as the Offshore Zone of Deformation (Woodward-Clyde, 1979) and is not fully understood. Several studies suggest that the Newport-Inglewood and the Rose Canyon faults are a continuous zone of en echelon faults (Treiman, 1984 ). Further studies along the complex offshore zone of faulting may indicate a potentially greater seismic risk than current data suggests. Other faults which could affect the site include the Coronado Bank, Elsinore, San Jacinto and San Andreas Faults. The proximity of major faults to the site and site parameters are shown on the enclosed Seismic Design Parameters. Liguefaction Potential Liquefaction is a process by which a sand mass loses its shearing strength completely and flows. The temporary transformation of the material into a fluid mass is often associated with ground motion resulting from an earthquake. C 0 Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 11 Owing to the medium-dense nature of the Pleistocene terrace deposits and the anticipated depth to groundwater, the potential for seismically induced liquefaction and soil instability is considered low. CONCLUSIONS 1) The subject property is located in an area that is relatively free of potential geologic hazards such as landsliding, high groundwater tables, liquefaction and seismically induced subsidence. 2) The existing fill, soil and weathered terrace deposits encountered on the site are unsuitable for the support of proposed footings and concrete flatwork in their present condition. These surficial deposits should be removed and replaced as properly compacted fill for the support of foundations, concrete flatwork and exterior improvements. 3) The proposed development should not adversely affect the adjacent properties provided the recommendations of this report are implemented during the design and construction phases. RECOMMENDATIONS Removals/Recompaction The existing fill, soil and weathered terrace deposits in the building pad should be removed and replaced as properly compacted fill. All fill should be keyed and benched into the underlying terrace Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 12 deposits. Removals should extend a minimum of 5.0 feet beyond the building footprint. A I: I (horizontal to vertical) temporary slope should be graded along the property lines. Fill should be benched into the temporary slope. Additional recommendations will be necessary based on proposed plans and actual field conditions encountered during grading. The depth of removals are anticipated to be on the order of3.5 feet. However, a minimum of 1.5 feet of fill should underlie footings. Most of the existing earth deposits are generally suitable for reuse, provided they are cleared of all vegetation, debris and thoroughly mixed. Prior to placement of fill, the base of the removal should be observed by a representative of this firm. Additional overexcavation and recommendations may be necessary at that time. The exposed bottom should be scarified to a minimum depth of 6.0 inches, moistened as required and compacted to a minimum of 90 percent of the laboratory maximum dry density. Fill should be placed in 6.0 to 8.0 inch lifts, moistened to approximately 1.0 -2.0 percent above optimum moisture content and compacted to a minimum of 90 percent of the laboratory maximum dry density. Fill, soil and weathered terrace deposits in areas of proposed concrete flatwork and driveways should be removed and replaced as properly compacted fill. Imported fill, if necessary, should consist of non-expansive granular deposits approved by the geotechnical engineer. Temporary Slopes/Excavation Characteristics Temporary excavations, up to 5. 0 feet, should be trimmed to a gradient of 1 : 1 (horizontal to vertical) or less depending upon conditions encountered during grading. The terrace deposits exhibit little C 0 Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 13 or no cohesion and some degree of sloughing may occur along the temporary slope face. Based on the concept plans, shoring is not anticipated. Based on our experience in the area, the Pleistocene terrace deposits are easily rippable with conventional medium to heavy earth moving equipment in good working order. Foundations The following design parameters are based on footings founded into non-expansive approved compacted fill deposits or competent terrace deposits. Footings should not span cut/fill transitions. Footings for the proposed structure should be a minimum of 12 inches and 15 inches wide and founded a minimum of 12 inches and 18 inches below the lower most adjacent subgrade at the time of foundation construction for single-story and two-story structures, respectively. A 12 inch by 12 inch grade beam or footing should be placed across the garage opening. Footings should be reinforced with a minimum of four No. 4 bars, two along the top of the footing and two along the base. Footing recommendations provided herein are based upon underlying soil conditions and are not intended to be in lieu of the project structural engineer's design. For design purposes, an allowable bearing value of 1700 pounds per square foot and 2000 pounds per square foot may be used for foundations at the recommended footing depths for single and two story structures, respectively. Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 14 For footings deeper than 18 inches, the bearing value may be increased by 20 percent for each additional foot of embedment and 10 percent for each additional foot of width of footing to a maximum of 3500 pounds per square foot. The bearing value may be increased by one-third for short durations of loading, which includes the effects of wind and seismic forces. The bearing value indicated above is for the total dead and frequently applied live loads. This value may be increased by 33 percent for short durations of loading, including the effects of wind and seismic forces. Sulfate Content Based on selective testing, the soluble sulfate content is negligible. Slabs on Grade (Interior and Exterior) Slabs on grade should be a minimum of 5.0 inches thick and reinforced in both directions with No. 3 bars placed 18 inches on center in both directions. Exterior slabs on grade should be a minimum of 4.0 inches thick and reinforced with No. 3 placed 18 inches on center in both directions. The slab should be underlain by a minimum 2.0-inch coarse sand blanket (S.E. greater than 30). Where moisture sensitive floors are used, a minimum 10.0-mil Visqueen, Stego or equivalent moisture barrier should be placed over the sand blanket and covered by an additional two inches of sand (S.E. greater than 30). Utility trenches underlying the slab may be backfilled with on-site materials, compacted to a minimum of 90 percent of the laboratory maximum dry density. Slabs including 0 Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 15 exterior concrete flatwork should be reinforced as indicated above and provided with saw cuts/expansion joints, as recommended by the project structural engineer. All slabs should be cast over dense compacted subgrades. Exterior slabs should be provided with weakened plane joints at frequent intervals in accordance with the American Concrete Institute (ACI) guidelines. Our experience indicates that the use of reinforcement in slabs and foundations can reduce the potential for drying and shrinkage cracking. However, some minor cracking is considered normal and should be expected as the concrete cures. Moisture barriers can retard but not eliminate moisture vapor movement from the underlying soils up through the slab. Lateral Resistance Resistance to lateral load may be provided by friction acting at the base of foundations and by passive earth pressure. A coefficient of friction of 0.25 may be used with dead-load forces. A passive earth pressure of 200 pounds per square foot, per foot of depth of fill or terrace deposits penetrated to a maximum of 2500 pounds per square foot may be used. Retaining Walls Cantilever walls (yielding) retaining nonexpansive granular soils may be designed for an active- equivalent fluid pressure of 38 pounds per cubic foot for a level surcharge. Restrained walls (nonyielding) should be designed for an "at-rest" equivalent fluid pressure of 60 pounds per cubic foot. Wall footings should be designed in accordance with the foundation design recommendations. Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 16 All retaining walls should be provided with an adequate backdrainage system. A geocomposite blanket drain such as Miradrain 6000 or equivalent is recommended behind walls. The soil parameters assume a level nonexpansive select granular backfill compacted to a minimum of 90 percent of the laboratory maximum dry density. Dynamic (Seismic) Lateral Earth Pressures For proposed restrained walls (non-yielding), potential seismic loading should be considered. For smooth rigid walls Wood (1973) expressed the dynamic thrust in the following form: 6Pe = kb YH2 (non-yielding) where kb is ½ peak ground acceleration equal to 50 percent of the design spectral response acceleration coefficient (Sds) divided by 2.5 per C.B.C. (2007), Y is equal to the unit weight of backfill and H is equal to the height of the wall. The pressure diagram for this dynamic component can be approximated as an inverted trapezoid with stress decreasing with depth. The point of application of the dynamic thrust is at a height of 0.6 above the base of the wall. The magnitude of the resultant is : 6Pe = 20.1 H2 (non-yielding) This dynamic component should be added to the at-rest static pressure for seismic loading conditions. Coast Geotechnical ,-... '-" 0 ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 17 For cantilever walls (yielding), Seed and Whitman (1970) developed the dynamic thrust as: aPe = 3/8 kh YH2 (yielding) The pressure diagram for this dynamic component can be approximated as an inverted trapezoid with stress decreasing with depth and the resultant at a height of 0.6 above the base of the wall. The magnitude of the resultant is: aPe = 7 .5 H2 (yielding) This dynamic component should be added to the static pressure for seismic loading conditions. Settlement Characteristics Estimated total and differential settlement over a horizontal distance of 30 feet is expected to be on the order of 1.0 inch and 3/4 inch, respectively. It should also be noted that long term secondary settlement due to irrigation and loads imposed by structures is anticipated to be 1/4 inch. Seismic Considerations Although the likelihood of ground rupture on the site is remote, the property will be exposed to moderate to high levels of ground motion resulting from the release of energy should an earthquake occur along the numerous known and unknown faults in the region. The Rose Canyon Fault Zone located approximately 4.3 miles west of the property is the nearest known active fault and is considered the design earthquake for the site. Coast Geotechnical Seismic Ground Motion Design Parameters ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 18 Seismic ground motion values were determined as part of this investigation in accordance with Chapter 16, Section 1613 of the 2013 California Building Code (CBC) and ASCE 7-10 Standard using the web-based United States Geological Survey (USGS) ground motion calculator. Generated results including the Mapped (Ss, S1), Risk-Targeted Maximum Considered Earthquake (MCER) adjusted for site Class effects (SMs, SM1) and Design (Sos, S01) Spectral Acceleration Parameters as well as Site Coefficients (Fa, Fv) for short periods (0.20 second) and I-second period, Site Class, Design and Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrums, Mapped Maximum Considered Geometric Mean (MCEo) Peak Ground Acceleration adjusted for Site Class effects (PGAM) and Seismic Design Category based on Risk Category and the severity of the design earthquake ground motion at the site are summarized in the enclosed Appendix A. Site Class D Seismic Design Category D Ss: 1.161 S1: 0.445 SMs: 1.203 SMI: 0.692 SDs: 0.802 SDI: 0.461 Fa: 1.035 Fv: 1.555 C Coast Geotechnical Preliminary Pavement Design 0 ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 19 The following preliminary pavement section is recommended for proposed driveways: 4.0 inches of asphaltic concrete on 6.0 inches of select base (Class 2) on 12 inches of compacted subgrade soils or 5 .5 inches of concrete on 12 inches of compacted subgrade soils Subgrade soils should be compacted to the thickness indicated in the structural section and left in a condition to receive base materials. Class 2 base materials should have a minimum R-value of 78 and a minimum sand equivalent of 30. Subgrade soils and base materials should be compacted to a minimum of95 percent of their laboratory maximum dry density. Concrete should be reinforced with No. 3 bars placed 18 inches on center in both directions. It is suggested that concrete be underlain by a minimum of 4.0 inches of Class 2 base. The pavement section should be protected from water sources. Migration of water into subgrade deposits and base materials could result in pavement failure. Utility Trench We recommend that all utilities be bedded in clean sand (S.E. greater than 30) to at least one foot above the top of the conduit. The bedding should be moistened and tamped in place to fill all the voids around the conduit. Imported or on-site granular material compacted to at least 90 percent relative compaction may be utilized for backfill above the bedding. ,-. Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 20 The invert of subsurface utility excavations paralleling footings should be located above the zone of influence of these adjacent footings. This zone of influence is defined as the area below a 45 degree plane projected down from the nearest bottom edge of an adjacent footing. This can be accomplished by either deepening the footing, raising the invert elevation of the utility, or moving the utility or the footing away from one another. Drainage Specific drainage patterns should be designed by the project architect or engineer. However, in general, pad water should be directed away from foundations. Roof water should be collected and transferred to hardscape. Vegetation adjacent to foundations should be avoided. If vegetation in these areas is desired, sealed planter boxes or drought resistant plants should be considered. Other alternatives may be available, however, the intent is to reduce moisture from migrating into foundation subsoils. Irrigation should be limited to that amount necessary to sustain plant life. All drainage systems should be inspected and cleaned annually, prior to winter rains. Geotechnical Observations Structural footing excavations should be observed by a representative of this firm, prior to the placement of steel and forms. All fill should be placed while a representative of the geotechnical engineer is present to observe and test. C Coast Geotechnical Plan Review 0 ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page 21 Only concept plans were available at the time of this study. A copy of the preliminary plans should be submitted to this office for review prior to the initiation of construction. Additional recommendations may be necessary at that time. LIMITATIONS This report is presented with the provision that it is the responsibility of the owner or the owner's representative to bring the information and recommendations given herein to the attention of the project's architects and/or engineers so that they may be incorporated into plans. If conditions encountered during construction appear to differ from those described in this report, our office should be notified so that we may consider whether modifications are needed. No responsibility for construction compliance with design concepts, specifications or recommendations given in this report is assumed unless on-site review is performed during the course of construction. The subsurface conditions, excavation characteristics and geologic structure described herein are based on individual exploratory excavations made on the subject property. The subsurface conditions, excavation characteristics and geologic structure discussed should in no way be construed to reflect any variations which may occur among the exploratory excavations. Please note that fluctuations in the level of groundwater may occur due to variations in rainfall, temperature and other factors not evident at the time measurements were made and reported herein. Coast Geotechnical assumes no responsibility for variations which may occur across the site. ,,_ Coast Geotechnical ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page22 The conclusions and recommendations of this report apply as of the current date. In time, however, changes can occur on a property whether caused by acts of man or nature on this or adjoining properties. Additionally, changes in professional standards may be brought about by legislation or the expansion of knowledge. Consequently, the conclusions and recommendations of this report may be rendered wholly or partially invalid by events beyond our control. This report is therefore subject to review and should not be relied upon after the passage of two years. The professional judgments presented herein are founded partly on our assessment of the technical data gathered, partly on our understanding of the proposed construction and partly on our general experience in the geotechnical field. However, in no respect do we guarantee the outcome of the project. This study has been provided solely for the benefit of the client and is in no way intended to benefit or extend any right or interest to any third party. This study is not to be used on other projects or extensions to this project except by agreement in writing with Coast Geotechnical. C Coast Geotechnical REFERENCES 0 ATTACHMENT 22 February 11, 2016 W.O. P-6541115 Page23 1. California Building Standards Commission, January 1, 2013, 2013 California Building Code, California Code of Regulations. 2. Petersen, Mark D. and others (DMG), Frankel, Arthur D. and others (USGS), 1996, Probabilistic Seismic Hazard Assessment for the State of California, California Division of Mines and Geology OFR 96-08, United States Geological Survey OFR 96-706. 3. Treiman, J.A., 1984, The Rose Canyon Fault Zone, A Review and Analysis, California Division of Mines and Geology. 4. United States Geological Survey, 2007, Seismic Hazard Curves and Uniform Hazard Response Spectra, Volume 5.0.8. MAPS/ AERIAL PHOTOGRAPHS 1. California Division of Mines and Geology, 1994, Fault Activity Map of California, Scale 1 "=750,000'. 2. Geologic Map of the Oceanside, San Luis Rey and San Marcos 7.5' Quadrangles, 1996, DMG Open File Report 96-02. 3. Tan, S.S., and Giffen, D.G., 1995, Landslide Hazards in the Northern Part of the San Diego Metropolitan Area, San Diego County, Plate 35A, Open-File Report 95-04, Map Scale I :24,000. 4. Transpacific Architects, 2016, Concept Plans, Breaker View Beach House, 3648 Carlsbad Boulevard, Carlsbad, California, Scale 1/ 4 "= 1 '. 5. U.S.G.S., 7.5 Minute Quadrangle Topographic Map, Digitized, Scale Variable. ATTACHMENT 22 APPENDIX A C 0 ATTACHMENT 22 LABORATORY TEST RESULTS TABLE I Maximum Dry Density and Optimum Moisture Content (Laboratory Standard ASTM D-1557-91) Sample Location B-1@ 1.5'-3.0' Max. Dry Density (pcf) 127.8 TABLE II Optimum Moisture Content 9.2 Field Dry Density and Moisture Content Sample Location B-1 @ 3.0' B-1 @ 10.0' B-1 @ 15.0' B-2 @ 5.0' B-2 @ 8.0' B-2 @ 16.5' Sample Location B-1@ 1.5'-3.0' (Remolded) Field Dry Density (pcf) 101. 3 106.2 109.7 101.7 117.0 108.7 TABLE III Direct Shear Test Results Angle of Internal Friction 0 29 Degrees (Page 1 of 2) Field Moisture Content ! 11.8 5.9 5.2 7.1 7.0 3.5 Apparent Cohesion (psf) 37 ATTACHMENT 22 TABLE V Water Soluble Sulfate California Test 417 Sample B-1@ l.5'-3.0' (Page 2 of 2) Sulfate Content (%) 0.034 (negligible) P-6541115 LOG OF EX:rLORATORY BOR NQr~t22 DRILL RIG: TRI-POD HOLLOW-STEM AUGER BORING DIAMETER: 6 O" SURFACE ELEV.: 56' (Approximate) ,...._ ~ 0 -...., f--< p:: ....; 5 z t.ll C ~ f--< µ., Q -< ~ ..... .e z ~ t.ll f--< 11.. -< >-0 t.ll f--< > 0 f-u u 5 t.ll 0 :ii ~ -< .....l .....l z ~ 0 t.ll u t.ll I-LI .._ 0 f--< u .....l ;I: 5:l >-r:n r:n ~ ~ f--< 11.. 0 § 11.. ~ f:l 0 t.ll ::E r/J .....l -< 0 0 p'.) r/J 101.3 11.8 7 'O Q.) C: Q.) Cl) .D 0 ~ Q.) 106.2 5.9 ~ ~ 'O § 0 ~ 34 0 0 z 109.7 5.2 57 43 SHEET l OF I :Fl u r:n 2 r.ri r:n -< .....l u d 0 r:n SM SP PROJECT NO. P-654111 5 DATE DRILLED: 01-12-16 LOGGED BY: MB GEOLOGIC DESCRIPTION Gravel Surface for Parkin SOIL(Qs) Brn. fine and medium-grained sand, silty TERRACE DEPOSITS (Qt): Tan to Reddish brn., fine and med.-graine weathered in upper 3.0' to 4.0' Loose becomes increasingly dense with depth Dense From 14', apparent increase in density V. Dense Dense End of Boring @ 20' COAST GEOTECHNICAL LOG OF EXPLORATORY BORINGAiNt>U\i1lNT22 DRILL RIG: TRI-POD HOLLOW-STEM AUGER BORING DIAMETER: 6.0" SURFACE ELEV.: 56' (Approximate) ,..._ e [--, ~ ,...; z z L1l C r.t.l [--, µ.. 0 <) [--, -ct: ~ i::: 8 z ~ w 0-.. ~ >-, 0 Lil [--, 8 [--, u u s r.t.l (.I) ~ -ct: -l ..-l z ~ 0 r.t.l u L1l L1l ----Q ..... u ....:I ::r: ~ >-, Cl) Cl) :3: ~ [--, P-, 0 ~ 0-.. ~ ~ 0 L1l Q ::E -l ~ Q Cl) en C/l 0 101 .7 7.1 21 "O (I) ;> 117.0 7.0 ... (I) u, .0 0 ... 25 (I) ~ ~ "O § 0 .... 0 0 z 108.7 3.5 58 SHEET 1 OF I :ii :..) Cl) 2 r/i Cl) -ct: ..-l u d 0 C/) SM SP PROJECT NO. P-6541115 DATE DRILLED: 01-12-16 LOGGED BY: MB GEOLOGIC DESCRIPTION Gravel Surface for Parkin SOIL(Qs): Bm. fine and medium-grained sand, silty TERRACE DEPOSITS (Qt): Tan to Reddish brn., fine and med.-graine weathered in upper 3.0' to 4.0' Med. Dense Med. Dense becomes increasingly dense with depth From 14', apparent increase in density V. Dense End of Boring @ 20' COAST GEOTECHNICAL ~~-·- 'f : 11-'ftlCH'T!~ --,. .. !~ .. .,(~ • 1 I : I --·--·-·-·-·-·-·-·-·-·-·--,s-___________ j..p-_ I I 0 > .....J CD 0 ~ i 1 I ~ I· Cl:'. ~ ·-•~ ,-, I: ~ --- ' ' tT--.1,: ' I ~j : i ·) ' =:-='-~ . ..ll_tilh... __ -~=-==--==---: '.~:-··-~----_j.:__ "-"'-""' I '1 'a"~.-2:-;:;~~~~~~~,£~.ft:UN~'.'SIO<Y~~o_C~:fi=~GAic-c~~~:f.,.~. ~:-_-_-_-. -•' ~ · .. ·-' . -~ ·1• ,[;\j-. ! , ' ' ,, • .,.. I I ! : l / \ t I ! \ 1 -J~ -~ ~ : .. .,.;, ••• ,.., ~I ' I UNT-. ' I ! I I : < . ..-1 : I ,• -. I • ~~ ' -.u.,1la._____ ~ '°'"'" cAAeoe, , : l , .. IM"'.e .... _J -,1 1 , DRIVEWAY I ~---· '"" .,.,~,' 8-2 : 1 • ; ·J (3 _!------ . o' l ------L _ /~ ~--t rr----------···--1 .. /~-1---------~--~· ·: .. -; !-,_ ·L JI ,- ?~;;t,,;;;,;;,':;, ': : : ~1 j' i -,~_;__ 111 . ;: 1· ~---.. ~ ~ -----1· -------,J ' 0 "ot,r·==:-~V---~: \TE1 _ _ _ -~ . ' = I ' (~cc;..,._-I~ -~' :·~-: ~-,Co<• ' GEOLOGIC UNITS af ARTIFICIAL FILL Qs SOIL Qt TERRACE DEPOSITS J, .,. . '· CONCEPT-SITE PLAN SCALE : Reduced LEGEND ♦ BORING LOCATION (approx.) +· ~o . QQ lb' ~ COAST GEOTECHNICAL P-654I115 C.,11) -1-~u c.,W cc l-a. -II) :c zu cc Ill: Ill: cc I- ~ ci :: .. Q .. m ~ a: .. '-' .. "' '° ,.., C, 3: ..., :;: ..., ,r, -;;i .. Q c;> "' -1 ~~ffi =~ ~1::.: ~i 0 < <~ :;: ..., ..., -= :c .. :c Cl u aii, ;; ... 5-, tll A-2.1 . C , ' C ~I ~ t C < ! ~- ~ ~ ~" • v. u -: ; ~ I.I ATTACHMENT 22 APPENDIXB ATTACHMENT 22 CALIFORNIA FAULT MAP KOVENS 150 100 50 0 -50 -100 -150 -200 -250 -300 -350 -400 -450 -500 50 100 150 200 250 300 350 400 450 500 550 600 Design Maps Summary Report http://ehpI-earthquake.er .gov/designmaps/us/summary.php?templa ... I of I ATTACHMENT 22 IIUSGS Design Maps Summary Report User-Specified Input Report Title KOVENS Mon January 25, 2016 19:57:38 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 33.15°N, 117.347°W Site Soil Classification Site Class D -"Stiff Soil" Risk Category I/II/III USGS-Provided Output 55 = 1.161 g 51 = 0.445 g 5145 = 1.203 g SM1 = 0.692 g 5 05 = 0.802 g S01 = 0.461 g For information on how the SS and 51 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 'ii, -II u, MCE11 Response Spectrum 1.43 1.30 1.17 1.04 0.,1 0. 711 o.,s 0.52 O.i5 0.2, o.n 0.00 -!---1---+--+---1>---+--t--+---+--+-----i 0.00 0.20 0.40 0.60 0.110 l.00 1.20 1.40 1.,0 1.80 2.00 Period, T (sec) 'ii, -II u, Design Response Spectrum 0.,0 O.QI 0.72 O.G) 0.54 0.45 0.36 0.27 0.19 o.o, 0.00 4---1---+--+-->---+--+--+---+--+----i 0.00 o.zo 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.110 2.00 Period, T (sec) For PGAM, TL, c.s, and c., values, please view the detailed report. Although this informatiOn Is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implied , as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. 1/25/2016 12:00 PM Design Maps Detailed Report http://ehp 1-earthqua usgs.gov/designmaps/us/report.php?teinplate ... · I of6 ATTACHMENT 22 IIUSGS Design Maps Detailed Report ASCE 7-10 Standard (33.15°N, 117.347°W) Site Class D -"Stiff Soil", Risk Category I/II/III Section 11.4.1 -Mapped Acceleration Parameters Note: Ground motion values provided below are for the direction of maximum horizontal spectral response acceleration. They have been converted from corresponding geometric mean ground motions computed by the USGS by applying factors of l. 1 (to obtain S5) and l. 3 (to obtain 51). Maps in the 2010 ASCE-7 Standard are provided for Site Class B. Adjustments for other Site Classes are made, as needed, in Section 11.4.3. From Fjqure 22-1 £11 Ss = 1.161 g From figure 22-2 c21 S 1 = 0.445 g Section 11.4.2 -Site Class The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or the default has classified the site as Site Class D, based on the site soil properties in accordance with Chapter 20. Table 20.3-1 Site Classification Site Class A. Hard Rock B. Rock C. Very dense soil and soft rock D. Stiff Soil E. Soft clay soil F. Soils requiring site response analysis in accordance with Section 21.1 -Nor Heh -Vs s. >5,000 ft/s N/A N/A M••-•••••MO••••••••-•-••---• M••• 2,500 to 5,000 ft/s N/A N/A ••·•··-········ .. -·-"""''""""""'"''"'"· 1,200 to 2,500 ft/s >50 >2,000 psf 600 to 1,200 ft/s 15 to 50 1,000 to 2,000 psf <600 ft/s <15 <1,000 psf Any profile with more than 10 ft of soil having the characteristics: • Plasticity index PI> 20, • Moisture content w ~ 40%, and • Undrained shear strengths. < 500 psf ····•··················-____ ,..,,-................................. -............. -·•··----- See Section 20.3.1 For SI: lft/s = 0.3048 m/s 1Ib/ft2 = 0.0479 kN/m2 1/25/2016 12:06 PM ·oesign Maps Detailed Report http://ehp 1-earthquak gs.gov/designmaps/us/report.php?template ... 2 of6 ATTACHMENT 22 Section 11.4.3 -Site Coefficients and Risk-Targeted Maximum Considered Earthquake (MCI;) Spectral Response Acceleration Parameters Table 11.4-1: Site Coefficient F, Site Class Mapped MCE R Spectral Response Acceleration Parameter at Short Period 55 :5 0.25 55 = 0.50 55 = 0.75 Ss = 1.00 55 ~ 1.25 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C 1.2 1.2 1.1 1.0 1.0 D 1.6 1.4 1.2 1.1 1.0 E 2.5 1. 7 1.2 0.9 0.9 F See Section 11.4. 7 of ASCE 7 Note: Use straight-line interpolation for intermediate values of 55 For Site Class= D and S5 = 1.161 g, F0 = 1.035 Table 11.4-2: Site Coefficient F, Site Class Mapped MCE R Spectral Response Acceleration Parameter at 1-s Period s, :5 0.10 s, = 0.20 s, = 0.30 s, = 0.40 s, ~ 0.50 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C l. 7 1.6 1.5 1.4 1.3 D 2.4 2.0 1.8 1.6 1.5 E 3.5 3.2 2.8 2.4 2.4 F See Section 11.4. 7 of ASCE 7 Note: Use straight-line interpolation for intermediate values of 51 For Site Class = D and S1 = 0.445 g, F, = 1.555 1/25/2016 12:06 Pl\ Design Maps Detailed Report http://ehp 1-earthqua usgs.gov/designmaps/us/report.php?ternplate ... · 3 of6 ATTACHMENT 22 Equation (11.4-1): S Ms = F.55 = 1.035 x 1.161 = 1.203 g Equation (11.4-2): SMl = FvSl = 1.555 X 0.445 = 0.692 g Section 11.4.4 -Design Spectral Acceleration Parameters Equation (11.4-3): 505 = ½ SMs = ½ X 1.203 = 0.802 g Equation (11.4-4): 501 = ½ SMI = ½ X 0.692 = 0.461 g Section 11.4.5 -Design Response Spectrum From figure 22-12 c3J TL = 8 seconds II II! c .!! 1, .. • • " " < • .. i a. ~ II a: ii t II a. II! Figure 11.4-1: Design Response Spectrum 500 = 0. 802 501 = 0.461 T0 = 0.115 T,=0.575 T < T0 : S. = S08 ( 0.4 + 0.6 TIT,) T0:ST:ST5 :S,=Soa T. <Ts Tl : s, =-so, / T T >Tl: s, = so,TJ'fl l.000 Period, T becl 1/25/2016 12:06 PT'v Design Maps Detailed Report http:/ /ehp 1-earthquak isgs.gov/designmaps/us/report.php?template ... 4 of6 ATTACHMENT 22 Section 11.4.6 -Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrum The MCE• Response Spectrum is detennined by multiplying the design response spectrum above by 'it s,.., = 1. 203 -" Ill c 0 i .. II ] " < I IA C 0 IL Ill II " ii t II IL Ill s_,..1 = o.692 T0 =0.115 1.5. 1.000 Period, T heel 1/25/2016 12 :06 PM Design Maps Detailed Report http ://ehp I-earthquake gs.gov/designmaps/us/report.php?ten'iplate ... · 5 of6 ATTACHMENT 22 Section 11.8.3 -Additional Geotechnical Investigation Report Requirements for Seismic Design Categories D through F From Figure 22-7 £4J PGA = 0.464 Equation (11.8-1): Table 11.8-1: Site Coefficient F,GA Site Class Mapped MCE Geometric Mean Peak Ground Acceleration, PGA A B C D E F PGA $ 0.10 PGA = 0.20 PGA = 0.30 PGA = 0.40 PGA ~ 0.50 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.1 1.0 1.0 1.6 1.4 1.2 1.1 1.0 2.5 1. 7 1.2 0.9 0.9 See Section 11.4. 7 of ASCE 7 Note : Use straight-line interpolation for intermediate values of PGA For Site Class= D and PGA = 0.464 g, FPGA = 1.036 Section 21.2.1.1 -Method 1 (from Chapter 21 -Site-Specific Ground Motion Procedures for Seismic Design) From figure 22-17 csi CRs = 0.934 From Figure 22-18 £6 1 C Rl = 0.987 1/25/20 16 12:06 PM ·Design Maps Detailed Report http://ehp I -earthquake ISg.s .gov/designmaps/us/report. pbp?template ... 6 of6 ATTACHMENT 22 Section 11.6 -Seismic Design Category Table 11.6-1 Seismic Design Category Based on Short Period Response Acceleration Parameter RISK CATEGORY VALUE OF Sos I or II III IV Sos< 0.167g A A A 0.167g :S Sos< 0.33g B B C 0.33g :S Sos< 0 .50g C C D O.SOg :S Sos D D D For Risk Category = I and Sos = 0.802 g, Seismic Design Category = D Table 11.6-2 Seismic Design Category Based on 1-S Period Response Acceleration Parameter RISK CATEGORY VALUE OF So1 I or II III IV S01 < 0.067g A A A 0.067g :S S01 < 0.133g B B C 0.133g :S S01 < 0.20g C C D 0.20g :S S01 D D D For Risk Category = I and S,,1 = 0.461 g, Seismic Design Category = D Note: When 5 1 is greater than or equal to 0.75g, the Seismic Design Category is E for buildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective of the above. Seismic Design Category = "the more severe design category in accordance with Table 11.6-1 or 11.6-2" = D Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category. References 1. Figure 22-1 : http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-1. pdf 2. Figure 22-2: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-2. pdf 3. Figure 22-12: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-12. pdf 4. Figure 22-7: http://earthquake.usgs.gov/hazards/designma ps/downloads/pdfs/2010_ASCE-7 _Figure_22-7. pdf 5. Figure 22-17: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-17. pdf 6. Figure 22-18: http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7 _Figure_22-18. pdf 1/25/2016 12:06 PM ATTACHMENT 22 APPENDIXC ATTACHMENT 22 GRADING GUIDELINES Grading should be performed to at least the minimum requirements of the local governing agencies, the California Building Code, 2013 , the geotechnical report and the guidelines presented below. All of the guidelines may not apply to a specific site and additional recommendations may be necessary during the grading phase. Site Clearin& Trees, dense vegetation, and other deleterious materials should be removed from the site. Non- organic debris or concrete may be placed in deeper fill areas under direction of the Soils engineer. Subdraina&e 1. During grading, the Geologist and Soils Engineer should evaluate the necessity of placing additional drains. 2. All subdrainage systems should be observed by the Geologist and Soils Engineer during construction and prior to covering with compacted fill. 3. Consideration should be given to having subdrains located by the project surveyors. Outlets should be located and protected. Treatment of Existin& Ground 1. All heavy vegetation, rubbish and other deleterious materials should be disposed of off site. 2. All surficial deposits including alluvium and colluvium should be removed unless otherwise indicated in the text of this report. Groundwater existing in the alluvial areas may make excavation difficult. Deeper removals than indicated in the text of the report may be necessary due to saturation during winter months. 3. Subsequent to removals, the natural ground should be processed to a depth of six inches, moistened to near optimum moisture conditions and compacted to fill standards. Fill Placement 1. Most site soil and bedrock may be reused for compacted fill; however, some special processing or handling may be required (see report). Highly organic or contaminated soil should not be used for compacted fill. 2. Material used in the compacting process should be evenly spread, moisture conditioned, processed, and compacted in thin lifts not to exceed six inches in thickness to obtain a uniformly dense layer. The fill should be placed and compacted on a horizontal plane, unless otherwise fowid acceptable by the Soils Engineer. (1) ATTACHMENT 22 3. If the moisture content or relative density varies from that acceptable to the Soils engineer, the Contractor should rework the fill until it is in accordance with the following: a) Moisture content of the fill should be at or above optimwn moisture. Moisture should be evenly distributed without wet and dry pockets. Pre-watering of cut or removal areas should be considered in addition to watering during fill placement, particularly in clay or dry surficial soils. b) Each six inch layer should be compacted to at least 90 percent of the maximum density in compliance with the testing method specified by the controlling governmental agency. In this case, the testing method is ASTM Test Designation D-1557-91. 4. Side-hill fills should have a minimwn equipment-width key at their toe excavated through all surficial soil and into competent material (see report) and tilted back into the hill. As the fill is elevated, it should be benched through surficial deposits and into competent bedrock or other material deemed suitable by the Soils Engineer. 5. Rock fragments less than six inches in diameter may be utilized in the fill, provided: a) They are not placed in concentrated pockets; b) There is a sufficient percentage of fine-grained material to surround the rocks; c) The distribution of the rocks is supervised by the Soils Engineer. 6. Rocks greater than six inches in diameter should be taken off site, or placed in accordance with the recommendations of the Soils Engineer in areas designated as suitable for rock disposal. 7. In clay soil large chunks or blocks are common; if in excess of six (6) inches minimwn dimension then they are considered as oversized. Sheepsfoot compactors or other suitable methods should be used to break the up blocks. 8. The Contractor should be required to obtain a minimwn relative compaction of 90 percent out to the finished slope face of fill slopes. This may be achieved by either overbuilding the slope and cutting back to the compacted core, or by direct compaction of the slope face with suitable equipment. If fill slopes are built "at grade" using direct compaction methods then the slope construction should be performed so that a constant gradient is maintained throughout construction. Soil should not be "spilled" over the slope face nor should slopes be "pushed out" to obtain grades. Compaction equipment should compact each lift along the immediate top of slope. Slopes should be back rolled approximately every 4 feet vertically as the slope is built. Density tests should be taken periodically during grading on the flat surface of the fill three to five feet horizontally from the face of the slope. (2) ATTACHMENT 22 In addition, if a method other than over building and cutting back to the compacted core is to be employed, slope compaction testing during construction should include testing the outer six inches to three feet in the slope face to determine if the required compaction is being achieved. Finish grade testing of the slope should be performed after construction is complete. Each day the Contractor should receive a copy of the Soils Engineer's "Daily Field Engineering Report" which would indicate the results of field density tests that day. 9. Fill over cut slopes should be constructed in the following manner: a) All surficial soils and weathered rock materials should be removed at the cut-fill interface. b) A key at least 1 equipment width wide (see report) and tipped at least 1 foot into slope should be excavated into competent materials and observed by the Soils Engineer or his representative. c) The cut portion of the slope should be constructed prior to fill placement to evaluate if stabilization is necessary, the contractor should be responsible for any additional earthwork created by placing fill prior to cut excavation. 10. Transition lots (cut and fill) and lots above stabilization fills should be capped with a four foot thick compacted fill blanket (or as indicated in the report). 11. Cut pads should be observed by the Geologist to evaluate the need for overexcavation and replacement with fill. This may be necessary to reduce water infiltration into highly fractured bedrock or other permeable zones, and/or due to differing expansive potential of materials beneath a structure. The overexcavation should be at least three feet. Deeper overexcavation may be recommended in some cases. 12. Exploratory backhoe or dozer trenches still remaining after site removal should be excavated and filled with compacted fill if they can be located. Gradini Observation and Testini 1. Observation of the fill placement should be provided by the Soils Engineer during the progress of grading. 2. In general, density tests would be made at intervals not exceeding two feet of fill height or every 1,000 cubic yards of fill placed. This criteria will vary depending on soil conditions and the size of the fill. In any event, an adequate number of field density tests should be made to evaluate if the required compaction and moisture content is generally being obtained. 3. Density tests may be made on the surface material to receive fill, as required by the Soils Engineer. (3) ATTACHMENT 22 4. Cleanouts, processed ground to receive fill, key excavations, subdrains and rock disposal should be observed by the Soils Engineer prior to placing any fill. It will be the Contractor's responsibility to notify the Soils Engineer when such areas are ready for observation. 5. A Geologist should observe subdrain construction. 6. A Geologist should observe benching prior to and during placement of fill. Utility Trench Backfill Utility trench backfill should be placed to the following standards: 1. Ninety percent of the laboratory standard if native material is used as backfill. 2. As an alternative, clean sand may be utilized and flooded into place. No specific relative compaction would be required; however, observation, probing, and if deemed necessary, testing may be required. 3. Exterior trenches, paralleling a footing and extending below a 1 : 1 plane projected from the outside bottom edge of the footing, should be compacted to 90 percent of the laboratory standard. Sand backfill, unless it is similar to the inplace fill, should not be allowed in these trench backfill areas. Density testing along with probing should be accomplished to verify the desired results. (4)