Loading...
HomeMy WebLinkAboutPD 2022-0003; KEMPER RESIDENCE; UPDATED GEOTECHNICAL REPORT; 2022-07-01ALL,IED EARTH TECHNC•LOGY ROBERT CHAN. P.E. 7915 SILVERTON AVENUE, SUITE 317 SAN DIEGO. CALIFORNIA 92126 PH. (858) 586-1665 FAX (858) 586-1650 (6 I 9) 44 7-474 7 UPDATE GEOTECHNICAL REPORT PROPOSED RESIDENTIAL BUILDING SITE 7133 A VIARA DRIVE CARLSBAD, CALIFORNIA FOR MR. STEVE KEMPER PROJECT NO. 21-1127C6 JULY 1, 2022 ALLIED EARTI-1 TECHNOLOGY 7915 SIL VER TON A VENUE. SUITE 317 SAN DIEGO. CALIFORNIA 92126 PH. (858) 586-1665 FAX (858) 586-1650 (619)447-4747 ROBERT CHAN. P.E. July 1, 2022 Mr. Steve Kemper Clo Marrokal Design Center 9474 Kearny Villa Road, Suite 205 San Diego, CA. 92126 Subject: Project No. 21-l 127C6 Update Geotechnical Report Proposed Residential Building Site 713 3 A viara Drive Carlsbad, California Dear Mr. Kemper : In accordance with your request, we have performed an update geotechnical report for the proposed residential building site on subject property, more specifically referred to as being Lot No. 29 of Tract No. 85-35, according to Map thereof No. 12412 (APN 215-610-28-00), in the City of Carlsbad, State of California. It is our understanding that a single-family residence is proposed for the site. The proposed structure, will be of wood-frame/stucco and slab-on-grade construction. The approximate location of subject property is shown on Figure No. 1, entitled, "Site Location Map". The purpose of this update geotechnical investigation was to inspect and determine the subsurface soil conditions and certain physical engineering properties of the soils beneath the site, so that engineering recommendations could be presented for the safe and economical construction of the residence as proposed. 1. In order to accomplish this purpose, the following were accomplished : a. Review of"As-Built Grading Plans, Aviara, Carlsbad Tract No. 85-35, Unit D" dated December 30 1991. b. Review of "As-Graded Geotechnical Repot, Units A through E, A viara, Carlsbad, California", dated January 18, 1990. Project No. 21-1127C6 Steve Kemper 07/01/22 Page2 7133 Aviara Drive c. A reconnaissance of the site, and the excavation of 3 exploratory trenches on July 20, 2021. d. Preparation of this Update Geotechnical Report to present our finding and recommendations. 2. From the review of documents and site inspection, it was determined that : a. Subject property is a rectangular-shaped property of approximately 0.25 acres, situated on the west side of A viara Drive. Topographically, the site is approximately 2 feet lower than the lot to the north and approximately 2 feet higher than the lot to the south. The site is graded as a split level lot, with a 5-foot descending slope between the eastern and western portions of the site. A descending slope at the west end of the existing pad building descends onto the A viara golf course. Proposed site grading will consist of slight elevation of the existing pads, and the import of 385 cubic yards of fill soils. b. The site was graded as part of the A viara development between April and November, 1989. Currently the site is vacant, and covered with low weeds. There were no evidence of any seepage, erosion or slope instability. c. Three exploratory trenches were excavated on the property. The location of these exploratory trenches ae shown on Figure No. 2, entitled, "Approximate Location of Exploratory Trenches". The exploratory trenches were excavated to a depth of 8 feet below existing ground surface. The soil type encountered consist of light brown/light gray, dense to very dense silty fine sand of the Torrey Sandstone Formation. Samples of the soils encountered were obtained for laboratory testing and analysis. The results of the laboratory test are presented on page L-1 hereto. Laboratory test results indicate that the on-site soils possess low expansion potential (Expansion Index= 22), and a sulfate content of 0.003%.(negliglble) d. Regional and local faulting With regard to local faulting, our review of the Geologic Map of the Encinitas and Rancho Santa Fe Quadrangles (Tan and Kennedy, 1996) indicates the site is not underlain by known active or potentially active faults. Tan and Kennedy (1996) indicate that several steeply dipping northwest trending short fault segments no Project No. 21-1127C6 Steve Kemper 07 /0 l /22 Page 3 7133 Aviara Drive more than a few hundred feet in length lie to the north and east of the site. The closest active fault is the Rose Canyon fault that lies offshore several miles to the west. The Coronado Bank Fault is the nearest regional fault and lies approximately 24 miles to the west. Other active regional faults, the Elsinore, San Jacinto, and San Andreas Faults lie approximately 28, 50, and 80 miles, respectively, to the east. e. Mapping of the Encinitas Quadrangle by Tan and Griffen for the California Division of Mines and Geology ( 1995) indicates the site lies in Hazard Category 3-1 defined as generally susceptible to land sliding particularly when adverse dips are present in graded cut slopes. Review of historic aerial photographs that predate the development of the property made for this report indicates there is no geomorphic evidence of past land sliding and it is concluded the presence of an ancient landslide in this area is unlikely. In addition, the original geotechnical report prepared by San Diego Soils Engineering for the development of the subdivision, then known as Pacific Rim Country Club and Resort ( dated January 29, 1986) also indicates that there re no landslides present in the area of Aviary Drive. Several large landslides were identified in that report that are present on the west side of the canyon below and to the west of A viara Drive. The presence of these landslides will not adversely affect the stability of the subject property. The geologic unit underlying the site as indicated by test pits placed during our geotechnical investigation of the site is composed of moderately cemented sandstone that is not prone to seismic induced land sliding or surficial instability. Manufactured and proposed slopes on the site do not exceed 5 feet in height and once they are properly landscaped with erosion resistant vegetation they will not be subject to surficial instability or creep. Since the site is underlain by sandstone bedrock, total and differential settlements are anticipated to be less than one inch across the length and width of the floor slab. The site is located 1.6 miles from the Pacific Ocean at an elevation of approximately 263 feet. Accordingly it is our professional opinion that the proposed residence will not be subject to tsunami inundation. The site classification and Spectral response characteristics are included on Page 6 of our geotechnical report. 3. Based on the results of the document review and site inspection, there appear to be no significant geotechnical hazard constraints on site that preclude the proposed development, and it is our opinion that the development is feasible from a geotechnical engineering Project No. 21-1127C6 Steve Kemper 07/01/22 Page 4 7133 A viara Drive standpoint, provided that the recommendations presented in this report are incorporated into the design plan(s) and are properly implemented during the construction phase: Grading a. There will be no impacts to adjacent property and improvements as a result of site grading and construction. b. The grading of subject property has been accomplished as part of mass grading of Aviara development in 1989, The grading of subject building pad had been done in accordance with the approved grading plans, and has remained substantially in the same condition, with no changes. It is our conclusion that the existing building pad is adequate for it intended purpose as support of the proposed residential building. However, the upper soils have been subject to weathering since grading was completed inl 989, and the upper 12 inches of the on-site soils were found to be dry and loose. c. It is recommended that the upper soils within 5 feet outside the foundation line of the proposed structure(s) be scarified to a depth of 12 inches. The scarified soils should be properly moistened, and uniformly compacted to at least 90 percent of maximum dry density in accordance with ASTM Dl557, in order to provide an uniform base for the slab of the proposed structure(s) Foundation and Slab Design d. It is recommended that a safe allowable soil bearing value of 2,000 pounds per square foot be used for the design and checking of continuous footings that are 12 inches in minimum horizontal dimension, and isolated pier footings that are 15 inches in minimum horizontal dimension, and are embedded at least 12 inches (for single story) and 18 inches (for two stories) below the surface of the competent natural or compacted fill soils. e. It is recommended that the continuous footings for the proposed structure(s) be reinforced with a minimum of 4 #5 rebars; two rebars located near the top, and the other two rebars near the bottom of the footings. All isolated pier footings should be reinforced with a minimum of 2 #5 rebars in both directions, placed near the bottom of the footings. f. The concrete slab-on-grade should be 4 ½ inches in thickness, and be reinforced with #3 rebars @ 18 inches on center in both directions, placed at mid-height of Project No. 21-l 127C6 Steve Kemper 07/01 /22 Page 5 7133 Aviara Drive concrete slab. The concrete slab should be underlain by 4 inches of clean sand, a 10-mil moisture barrier and covered by another inch of clean sand. The above foundation and slab reinforcement requirements are based on soil characteristics, and should be superseded by the requirements of the project architect. g. Foundations placed closer to the existing slope should be deepened such that the outer edge of the foundation along the bottom is at least 5 feet back from the face of slope at that level. h. It is recommended that our firm inspect the foundation trench excavations to ensure proper embedment into competent natural or compacted fill soils. 1. The soils in the exploratory trenches were loosely backfilled after completion of the field investigation. It is recommended that these exploratory trenches be located during the development of the site, and the backfill sols removed and them properly compacted with a backhoe mounted sheepsfoot roller. J. It is recommended that surface drainage along the perimeter of the building be allowed to flow away from the structure at a minimum gradient of 2 percent for a distance of at least 5 feet. No surface water is permitted to pond adjacent to the structure. k. The on-site soils possess negligible sulfate content. The on-site soils also possess low expansion potential, and no special design of foundation and slab to resist the detrimental effects of expansive soils are necessary. I. According to the project civil engineer, no infiltration of on-site storm water is proposed. Lateral Loading m. To resist lateral loads, it is recommended that the pressure exerted by an equivalent fluid weight of 300 pounds per square foot per foot of depth (maximum of 1,200 pounds per square foot) be used for footings or shear keys poured neat against competent natural or compacted fill soils. The upper 12 inches of material in areas not protected by floor slabs or pavements should not be included in the design for passive resistance. This value assumes that the horizontal distance of the soil mass extends at least 10 feet or three times the height of the surface generating the passive pressure, whichever is greater. Project No. 21-1127C6 Steve Kemper 07/01 /22 Page 6 7133 Aviara Drive n. A coefficient of sliding friction of 0.35 (total frictional resistance equals coefficients of friction times the dead load) may be used for cast-in-place concrete on competent natural or compacted fill soils. Footings can be designed to resist lateral loads by using a combination of sliding friction and passive resistance. The coefficient of friction should be applied to dead load forces only. o. Seismic earth pressures can be taken as an inverted triangular distribution with a maximum pressure at the top equal to 12H pound per square foot (with H being the height ofretained earth in feet). This pressure is in addition to the static design wall load. The allowable passive pressure and bearing capacity can be increased by 1/3 in determining the stability of the wall. A factor-of-safety of 1.2 can be used in determining the stability of the retaining wall under seismic conditions. p. The seismic coefficients in accordance with the current California Building Code were determined and the results are presented below : Site Coordinates : Latitude = 33.1014 Longitude = -117.0290 Site Class = C Spectral Response Acceleration At Short Periods Ss = 0.896 g Spectral Response Acceleration At I -second Period SI = 0.326 g Sms = FaSs = 1.075 g Sml = FvSl = 0.489 g Sds = 2/3*Sms = 0.717 g Sdl = 2/3*Sml = 0.326 g Seismic Design Category = D Fa = 1.2 Fv = 1.5 q. In consideration of the competent natural and compacted fill soils underlying the site, and the lack of a permanent groundwater table near the ground surface, it is our opinion that soil liquefaction does not present a significant geotechnical hazard to the proposed site development r. It is recommended that our firm review the foundation plans to ascertain that the recommendations presented herein are incorporated. s. We have reviewed the project grading and foundation plans, and confirmed that the plans have been prepared in accordance with the geotechnical recommendations. Project No. 21-1127C6 Steve Kemper 07/01 /22 Page 7 7133 Aviara Drive t. It is further recommended that the proposed residence be constructed in accordance with the approved plans and applicable regulations, except where items 2(a) to sr) above are more stringent. Page L-1 , and Figure Nos. I to 5, inclusive are parts of this report. Michael W. Hart CEG 706 Engineering Geologist Project No. 21-1127C6 Steve Kemper 7133 Aviara Drive REFERENCE 07/01/22 -Aerial Photographic, vertical -San Diego County, 1978/79, flt 15, frames 33 and 34 California Building Code, 2019, Title 24, Part 2 Volume l & 2 Page 8 California Department of Conservation, Division of Mines and Geology (California Geological Survey), 1997. -Civil Landwork -Grading Plan for Kemper Residence, dated February 17, 2022 Foundation and Earth Structures, Naval Facilities Engineering Command, DM7.02 "Green Book" Standard Specifications for Public Works Construction, Public Works Standards, 2018 edition. Kennedy, M.P. and Tan S.S., 2005 Geologic Map of the San Diego 30' x 60' Quadrangle, California Geologic Survey and U.S. Geological Survey digital map series. Lindavall, S.C., Rockwell, T.K., and Lindvall, C.E., 1990, the seismic hazard of San Diego revised: New evidence of Magnitude 6+ Holocene earthquakes on the Rose Canyon Fault Zone, in Proceedings of U.S. Tan. S.S., and Kennedy, M.P., 1996, Geologic Maps of the Encinitas and Rancho Santa Fe 7.5 min. Quadrangle, Calif., DMG Open File Report 96-92. Tan, S.S.,and Giffen, 1995, Preliminary Landslide Map of the Encinitas Quadrangle, Calif. Div. of Mines and Geology, DMG open file report 95-04. Project No. 21-l 127C6 Steve Kemper 07/01 /22 Page L-1 7133 Aviara Drive LABORATORY TEST RESULTS 1. The Expansion Index of the most clayey soils was determined in accordance with A.S.T.M. D4929-08. The results of the test are presented as follows: Soil Type 1 Soil Expansion Description Index Light brown/light gray silty fine sand (SM) 22* *Considered to possess LOW expansion potential LABORATORY R E P O R T Telephone (619) 425-1993 Fax 425-7917 Established 1928 CLARKSON LABORATORY AND SUPPLY INC. 350 Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab .com A N A L Y T I C A L A N D C O N S U L T I N G C H E M I S T S Date: May 25, 2022 Purchase Order Number: NONE Sales Order Number: 55755 Account Number: A.TORC To: *-------------------------------------------------* Torres Construction 5267 Edge Park Way San Diego 92124 Attention: Arturo Torres Laboratory Number: SO8852 Sample Designation: Customers Phone: 619-756-5665 *-------------------------------------------------* One soil sample received on 05/23/22 at 10:25am, marked as follows: ANALYSIS: Water Soluble Sulfate ($04 ) California Test 417 (Turbidity Method) Sample #1 7133 Aviara Dr Rosa Bernal ,RMB/arr 0.003 Ism NOT TO SCALE PROJECT NO. 21-1127 C6 FIGURE N0.1 7129 AWAA DRIVE LOT 290 APN: 215-610-29 MAP NO.: 12412 ~2tiJi!J;iP _.: ··"'<{>-'!. · · -~'-." -:-:E'~;::;-. r·'=1 . ·~•.;_,_.-·.L ... . .. .I .•.· •• ,,~ • -.::-.-:::-> I I · · [ L:.. _ •. , • · , 3 1', .. · .. · .. ·1r •J ~ _,_-' · -· ---"·:-:--:--: .• .,.-Ii -• ,_ r.......:::r ---= -, . • .· .. · .· .:.: . .-•·. ( . .. • 4• .••• ,,~ .··,I " •·• · ol , . ; · . · • • LOT 289 . ff;\: : •, . APN:215-610-28 1 It~ ~~ .. -. MAPN0.12412 _' · I llJ/~ ~l~L~~ {g:' : • 1#2 -. ___ .....:111 :t 1-· • ' .· !fi t~ . . . . . ji3" I L 'C .1J,1 l r. i I I L ~ .r •. . . . . 'J/~-:.i ,, ~"!:if ..... · .. , ·• . -2 ~r .. ·:-::-:: ·: • . • . • ,< L . • ._-.. • ·.; .. · .. , ..• :~ .. :_._.-. t --. 1t ~i;;,,-.t · II -· ,.,. -· .-://;¥tiff// .... · ~-. : ~ ----·. .-:. : ·.{\:}\ . :-~-. -~--ll =r ···-·>{:·.-t· i·rt·t· 'Jf::-,-.FT"--J ... · .:,._ .... ·-.i,;.;:_ . ~-,;;Jl._-. •• ~ ••• 'l ..... :< ~-~ 7---'-!--.:...1•·.· -1-· .. -_._.-_:-.:.:~--=-:-1:7:\..T • ~':--~~ ·• • . ·' ,i,._I .· ... •. : : ·-~·-·:-·:-:.:.: ·.• .·,:-....::-:.·:-:.·.:~ . -. SITE PLAN AND GEOLOGIC MAP 7133 AVIARA DRIVE, CARLSBAD, CALIFORNIA LEGEND II I I I I I l I I i~ <( I I ~ ~ k_ c--: ·-, ·---... _____ t' .,.2 I I ,,:,A.1' ;~. I NOTTO SCALE, I I APPROXIMATE LOCATION OF EXPLORATORY TRENCHES ~ Approximate Location of Exploratory Trench T t TORREY SANDSTONE PROJECT NO. 21-1127 C6 FIGURE N0.2 FT. 0 TRENCH LC)G SHEET TRENCH NO 1 Elev. 262' ms! DESCRIPTION Light brown/light gray, loose (Torrey Sandstone) 1 ______________ _ Damp, medium dense 2 3 4 5 6 7 8 Moist, dense BOTTOM OF TRENCH (No Refusal) LEGEND SOIL TYPE SILTY FINE SANO (SMi 0 -Indicates representative sample Project No. 21-1127(6 Figure No. 3 FT. (J I 1 TR ENC H LC) G SH E ET TRENCH NO . 2 Elev. 262 • msl DESCRIPTION Light brown/light gray, dry, loose (Torrey Sandstone) -~---------------- 2 3 4 5 6 7 8 Medium dense Moist, dense SOIL TYPE SILTY FINE SAND (SM ) ·------------·-------·-----____ r BOTTOM OF TRENCH (No Refusal) Project No. 21-1127C6 Figure No. 4 , -I I I ; . ' I I I I ! ! ' FT. l f :J i I I i ! I r I ! I I ~ I I I 3 I ~ I .. I s I 5 7 8 Project No. 21-1127C6 TRENCH LOG SHEET TRENCH NO. 3 E/ev. 266* msl DESCRIPTION Brown, damp, oose (Torrey Sandstone) Medium dense Moist, dense TRENCH (No Refusal) SOIL TYPE SIL TY FINE SAND (SM Figure No. 5