HomeMy WebLinkAboutCT 84-09; CARLSBAD RESEARCH CENTER SERIES 6000 TM; Tentative Map Exhibit::..
R "'
I I
\
I
\ \
\ \ \
I
TENTATIVE MAP FO~ i.SERIES 5000
~ 0 R [l "' 0 / ~ -/
/
I
I I I I I 9/4.67' I
~ 0 -·--------~ ~ ~ g ~
I
.
/ ! i/ I '
I
I \) I I'. I '. . I ,
' \ \. ,/ \
C.T. 84-~I :
11
I
~.D.67
---------"'.""'"'--""'."'""-----===-===-~::-::-~ -::;-""".'"""""""" ____ "!-__ +-________ _ --NER/DEVELOPER ENGINEER OF WORK i
\
I I I
\ I
\ \,
'· \ (COMMON. LOT)
, t.5 ac.
\
\
.
304.5
.5tac. ·,,
CID
81::0G. 6018
304.-0
y
b"' \ ,
~ \
\~ ' I \ I -~
\
-I ' .
>.:63 . ~ .
. ~
0 \ -
\ \
®
BLDG. 60 6-,
"'
' I-----"-
I • ~ .c
scale: 1" 50'
I
CARLSBAD RESEARCH CENTER
7330 ENGINEER ROAD
SAN DIEGO, CALIFORNIA 92101
(619) 292-5550
I, I
LEGAL DESCRIPTION
RICK ENGINEERING COMPANY
3088 PIO PICO DRIVE
CARLSBAD, CALIFORNIA 92008
(619) 729-4987
C:--£.
ROBERT C. LADWIG L.S. 3189
LOTS·-2 ANO 3 OF RECORD MAP 10330 RECORDED FEBRUARY 18;
1982 IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO,
ST A TE OF CALIFORNIA.
ASSESSOR'S PARCEL NUMBER: 212-061-01 & 02
I I, I
GENERAL NOTES
1. TOTAL ACREAGE: 15.79 AC. (GROSS)
i 2. NUMBER OF LOTS: S.-
• 1 3. .EXISTING ZONING: C-M
I 4. PROPOSED ZONING: C-M
' ' 5. EXISTING GENERAL PLAN DESIGNATION: Pl
r • I r IT 11 6,4 PROPOSED GENERAL PLAN DESIGNATION: Pl
BLDG. 602,~
310.5
"' 6• ."'-.: -ac.
,... ,a,'-<------1
13//7 ·, , ____..-r=
, .
,f;~:~~'l.-:
~AClflC
OCEAN
NO .SC"-1.E
. "'
•'
.. ,..
-,. ~iifl""'\
Leucadia ,,
• ~ "-! -·t ....... ~ /-
, I VICINITY MAP
,-I :.i-a
a,,.,,. \ SIT
\ ____, I --~
~f~ijf.l~~~I~ ';:;:t4),:,::;.....ll\
,i.., '·" -~\ ------.___.....,\
,,
LOCATION MAP-
7€1 ----0 ~..,:: ~::::=--~ ~~~ ~
6x_p· vcP....... ,
=------==
~1 PLANS, OWG. +212-~~R~O-,,C'F--T.:._::._,,81-44
zL1"f2C I' " '3 .. a~-p.0'1'€.~~E::::-===---------'-1 __ -.::'...---.i e;JC p. \y,,• ::.:=......-: -__
I 7. STREET RIGHT-OF-WAY WIDTHS ARE SHOWN ON MAP.
1 8. FINISH GRADES SHOWN HEREON ARE APPROXIMATE
ONL V AND ARE SUBJECT TO CHANGE IN FINAL DESIGN.
I 9. CUT AND FILL SLOPE 2:1 UNLESS~OTHERWISE SHOWN. 1
1
10. EXISTING GROUND CONTOUR INTERVAL IS 1 FT. OR 10 FT. (M.S.L.)
11. ONSITE SEWER ANO WATER TO BE APPROVED BY CITY
ENGINEER IN FINAL DESIGN.
12. PUBLIC SERVICES AND DISTRICTS:
GAS & ELECTRIC -SAN DIEGO GAS & ELECTRIC
TELEPHONE -PACIFIC BELL
WATER -CITY OF CARLSBAD/ COSTA REAL:M.W.O.
SEWER -CITY OF CARLSBAD
STORM DRAIN -CITY OF CARLSBAD
FIRE DISTRICT -CITY OF CARLSBAD ,
I SCHOOL DISTRICT -CARLSBAD UNIFIED [SCHOOL DISTRICT
1
13. EASEMENTS AS REQUIRED BY CITY ANO DISTRICTS.
I 14.. ALL PROPOSED UTILITIES TO BE UNDERGROUND. ,.
,15 •. STREET LIGHTS AS REQUIRED BY CITY ENGINEER.
16., FIRE HYDRANTS AS REQUIRED BY CITY ENGINEER & FIRE MARSHAL
,17: FOR BLOG. DETAILS & PARKING TABl,ILATION, SEE ARCH. SITE PLAN.
:18 .. AS SPECIFIED IN SECTION 66456. 1 OF THE SUBDIVISION MAP
I~ ACT, MULTIPLE FINAL MAPS MAY BE FILED ON THIS PROJECT.
19. EXISTING UTILITIES ON-SITE TO BE RELOCA TEO AS REQUIRED.
120. ESTIMATED GRADING QUANTITY: CUT:; 12,000 C. Y. FILL: 12,000 C. Y.
.LEGEND
SUBDIVISION BOUNDARY
1 EXISTING SEWER W/ MANHOLES
! ! EXISTING STORM DRAIN WIG.OJ INLET
II EXISTING WATER
. EXISTING FIRE HYDRANT
11 EXISTING STREET LIGHT
----·--0
------=·------= ---
I' 1f'/L -fIJ)
J( ~ "ftLOcfl'[, ~E-'°'uE. 1
1
'
1
' EXRISTING ELEVATION
P OPOSED 1::LEVATIONS ii PROPOSED STORM DRAIN ,INLET & CLEANOU i Im
.
1
,, PROPOSED LOT LINE W/ DIMENSIONS
~
1310 I
~
=====,■, Eil
IZ4' f]( eJ' w':J. \ £]( ,
~ \
\
,,....~
""
~
t>v.,t:.s1'\. -i
DRIVEW AV SECTION
zo·
PARKING
STALL
2%Typ
~
24'
DRIVEWAY
z~TYP -
ZO'
PARKING
STALL
.4CPAVEM€NT~
~3' PCC SIVALE YA C /G"A B
SECTION A-A
2'/t'MIN
. LOT NUMBER
. ' I
I
NOTES (con't)
1 21. NO WATERCOURSES OR AREAS SUBJECT TO INUNOA TION
I
FROM FLOODS ARE EXISTING.
22. NO MAJOR VEGETATION EXISTING.
I
23. NO EXISTING OR PROPOSED PUBLIC OR PRIVATE EASEMENTS'
EXISTING.
REVISED APRIL 26, 1984
DA TE PREPARED: MARCH 6 1984
RICK ENGINEERING· COMPANY
308B PIO PICO DRIVE CAFlLSBAD CA 92008 (819] 72!a}-4987 365 SOWTH ~TA FE ~c SUITE 1CCl SAr,.J fVIIAiF=ICOS CA seoas CB1Sl744-4BOO
c1v1J ENGINEERS· SURVEYORS· PLANNING CONSULTANTS .
i==:ss8 J+ 9111
. I