Loading...
HomeMy WebLinkAboutCT 12-01; MILES PACIFIC SUBDIVISION; Tentative Map ExhibitTENTATIVE MAP & COASTAL DEVELOPMENT PLAN CT 12-01/PUD 12-08/CDP 12-15 BENCifMARK CITY OF CARLSBAD PT. NO. 139 (RECORD OF SURVEY 17271) DESCRIPTION: FD. CADT DISK IN SOUTH SIDEWALK NEAR THE EAST END OF LAS F1-0RES DRIVE BRIDGE OVER INTERSTATE 5. STAMPED 5-50. 7, 1989. LOCATION: MONUMENT IS IN SOUTH SIDEWALK NEAR THE EAST END OF LAS F1-0RES DRIVE BRIDGE OVER INTERSTATE 5, 50 FT. £AST OF CENTER OF OVERPASS AND 2.5 FT. SOUTH OF CURB. ELEV: 82.221 DA TUM: NA VD29 BASIS OF BEARINGS THE BASIS OF BEARINGS FOR THIS SURVEY IS A PORTION OF THE EASTERLY RIGHT-OF-WAY OF ROUTE 11-SD-5, AS SHOWN ON MS 734; /.£ NORTH 3-1'26'53• IIE'ST. SAID BEARING AND TH£ BEARINGS SHOWN HEREON AR£ IN TERMS OF THE CAUFORNIA COORDINATE SYSTEM 27 ZONE 6. QUOTED BEARINGS FROM REFfRENCE MAPS OR DEEDS MAY OR MAY NOT BE IN TERMS OF SAID SYSTEM. LEGAL DESCRIPTION A PORTION OF TRACT 7 OF LAGUNA MESA TRACTS, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CAUFORNIA, ACCORDING TO MAP THEREOF NO. 1719, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JUNE 21, 1921. APN'S: 156-351-0.J, 07 .t 08 SITE ADDRESS: 2373 .t 2375 PIO PICO DRIVE, CARLSBAD, CA 92008 EASEMENT NOTES (TI -ABUTTER'S RIGHTS RELEASED .t RillNQU/SHED TO INTERS TA TE 5 FREEWAY, PER DOCUMENT RECORDED: NOVEMBER 5, 1951, IN BOOK 4281, PAGE 412, DOCUMENT / 133960 OF OFFICIAL RECORDS. lg) -8.00 FOOT EASEMENT FOR PUBUC UT/UT/£5, INGRESS .t EGRESS TO SAN DIEGO GAS .t ELECTRIC COMPANY, RECORDED: JUN£ 6, 1966, AS !)OCUMENT / 92989 OF Off/CIAL RECORDS. !JI -12.00 FOOT EASEMENT FOR PUBUC UT/UT/ES, INGRESS .t EGRESS TO SAN DIEGO GAS &- ELECTRIC COMPANY, RECORDED: JULY 22, 1966, IN DOCUMENT/ 119604 OF OFFICIAL RECORDS. @] -10.00 FOOT EASEMENT FOR SEIIE'R PURPOSES TO THE CITY OF CARLSBAD, RECORDED: JULY 28, 1961, IN DOCUMENT/ 110843 OF OFFICIAL RECORDS. ~ -ABUTTER'S RIGHTS RELEASED &-RELINQUISHED TO INTERSTATE 5 FREEWAY PER DOCUMENT RECORDED: JULY 15, 1969, IN DOCUMENT/ 126759 OF OFFICIAL RECORDS. [§] -AGREEMENT OF RECIPROCAL SEIIE'R EASEMENT BETWEEN MILES PACIFIC UM/TED PARTNERSHIP &- FRANK/LORIGENE SOHAEI, RECORDED: JANUARY 24, 2011, AS DOCUMENT I 2011-0042671 OF OFFICIAL RECORDS. [ZJ -12.00 FOOT EASEMENT FOR PUBLIC UTILITIES, INGRESS &-EGRESS TO SAN DIEGO GAS .t ELECTRIC COMPANY, RECORDED: JULY, 22, 1966, IN DOCUMENT/ 119603 OF OFFICIAL RECORDS. HYDROLOGY AND HYDRAULIC REPORT SEE HYDROLOGY AND HYDRAULIC REPORT PREPARED BY BHA, INC. AND DATED MAY 24, 2012 GEOTECHNICALREPORT GEOSO/LS, INC. 5741 PALMER WAY CARLSBAD, CA. 92010 (760) 438-3155 FOR ,,;~>'· MILES -PACIFIC SUBDIVISION, CARLSBAD, CA r C 1 9 10 □ .:.:Z"\ KEYMAP ' -351 I . \, 56□ o;";===""'~ • "' IT--1-r--~ I I I I t~ 1c---1-.-I I ' -LAS FLORES DRIVE 'I KEY MAP LEGEND SHEET REFERENCE PROJECT BOUNDARY ---(W) --EXISTING WATER MAIN ---(SJ ---EXISTING SEWER MAIN M EXISTING FIRE HYDRANT [::«I PROPOSED FIRE HYDRANT o---Q EXISTING STREET LIGHT ~ PROPOSED STREET LIGHT ---en ---EXISTING TELEPHONE ---(E) --EXISTING ELECTRICAL SHEETINDEX 1 COVER SHEET 2 PLAN l-1EW {LOTS 1-4, 12-17) 3 PLAN l-1EW {LOTS 5-11) 4 DEMOL! TION PLAN 5 REMEDIAL GRADING EXH/8/ T FEMANOTE 100· 5o' o· 100' 200· ~EXISTING FIRE HYDRANT PANEL NO. 0607JC0761F, DA TED: JUNE 19, 1997 PANEL NO. 06073C0762F, DA TED: JUNE 19, 1997 ZONE: X (AREAS DETERMINED TO BE OUTSIDE 500 YEAR F1-00D PLAIN) LEGEND ~ _;5,5 ----"'1G --36'-- -(W)--(W)- --(SJ --CSJ - --(G)--{G)--- -(E)--(E)- --(T) --(T) - --s --s -- -s --O--s -----w --w ----,® ----,® [::«I M y y y EXISTING ELEVATION PROPOSED ELEVATION PROPOSED AC PVMT/BASE SLOPE DIRECTION FINISH GRADE CONTOUR PROJECT BOUNDARY RIGHT OF WAY LINE EXISTING WA TER LINE EXISTING SEWER LINE EXISTING GAS LINE EXISTING OVERHEAD ELECTRIC LINE EXISTING OVERHEAD TELEPHONE UNE EXISTING CONTOUR MAJOR EXISTING CONTOUR MINOR PROPOSED SEIIE'R UNE PROPOSED SEIIE'R MANHOLE PROPOSED WATER UN£ PROPOSED SEIIE'R LA TERAL PROPOSED WATER METER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED RETAINING WALL PROPOSED 6' HIGH MASONRY SOUND WALL (SI.UMP STONE) PROPOSED SLOPE EMBANKMENT PROPOSED SETBACK AREA PROPOSED BROW DITCH K: \Land Projects J\901-1224-400\DWG\ TM\901-124-TMOl.dwg 7-72-2013 5' WIDE SIDEWALK 5' 2X - 29' 58' 29' PROPOSED 4• AC PVMT OVER 4• AB {MINIMUM) TYPICAL SECTION STREET A (PRIVATE)· LOT 20 NOT TO SCALE Tl = 4.5 J4" 17' 17' 12' 12' 3• PERl-10US INTER-LOCKING PA VERS {ORCO AQUA-BRIC I OR EQUIV/LENT) 2X - PROPOSED 4• AC PVMT OVER 4• AB (MINIMUM} TYPICAL SECIION STREET B (PRIVATEDRIVEAISLE)-LOT20 NOT TO SCALE Tl = 4.5 2X - 5' 2X - 4.5' WIDE SIDEWALK SCALE: 1• = 100' 0.5' 5' WIDE SIDEWALK STREET 'A• PROPOSED AC PVMT/AB PROJECT LOCATION R/W 40' 20' It 10' 10'± 3'± I 4% -- R/W 20' 8'± CROWN 2,¥ :=--c... _ _J, ~ EXISTING AC PVMT ct BASE --p'\i \.._EXISTING GROUND PROPOSED CONCRETE CROSS GUTTER TYPICAL SECTION ..... ~ lHIS IS fflEAPl'ROIID18fA11vrlid/Sl'II PLAN FOR PROJECJNO, a.-r l~-o I NICINDIIION NO. '7 OFtAIUIIADPIMllil"' COMMISSION RESOWIIOllllft. p 'j 8 6 ~/A(t1 J'AA ~ 1kof1, PLAHN.IHGDMSION DATE EJIGJNEERIN~ DATE f1-0RES DR/ VE REV. DESCRIPTION DATE APPD VICINITY MAP N. T.S. - /~· RONALD L. HOLLOWAY NO. 29271 ('Jyl\, OWNER'S CERTIFICATE 11£' HEREBY C£RnFY Tl-IA r 11£' ARE THE RECORD OWNERS OF Tl-IE PROPERTY SHOWN ON THE TENTATIVE SUBDIVISION MAP AND Tl-iAT SAID MAP SHOWS ALL OUR CONTIGUOUS OWNERSHIP IN WHICH 11£' HA VE ANY DEED OR TRUST INTEREST. 11£' UNDERSTAND Tl-iAT OUR PROPERTY IS CONSIDERED CONTIGUOUS EVEN IF IT IS SEPARATED BY ROADS, STREETS, UTIUTY EASEMENT$, OR RAILROAD RIGHTS-OF-WAY. OlVNER/DEVELOPER ROBERT MILES MILES PACIFIC UM/TED PARTNERSHIP 18J3 BUENA VISTA WAY CARLSBAD, CA 92008 PHONE: 760-889-9011 ROBERT MILES, PARTNER ENGINEER OF WORK bl-tA,lnc. DATE land planning, clvll engineering, surveying 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 RONALD L. HOLLOWAY RC£ 29271 PROJECT DATA ZONING DATE R-1 {FAMILY RESIDENTIAL) GENERAL PLAN DESIGNATION LAND USE RLM {LOW-MEDIUM DENSITY 0-4 DU/AC) RES/DEN TIAL COASTAL ZONE DRAINAGE DISTRICT: SITE AREA DWELLING UNITS LOT SIZE: EXISTING DENSITY PROPOSED DENSITY GRADING QUANTITIES CUT FIU REMEDIAL AREA OF GRADING VOLUME OF GRADING PER GRADED ACRE SETBACK DATA FRONT SIDE REAR AVERAGE DAILY TRAFFIC EXISTING: PROPOSED: INCREASE: PUBLIC UTILITIES YES A {NW QUADRANT} 5.4 AC 17 D/U 7,525 SF. TO 13,626 SF. 4.00 DU/AC. 3.15 DU/AC. 9,910 CY. 9,910 CY. 59,300 CY. 6.2 ACRES (INCLUDES OFFS/TE AREA} 1598 CY. PER GRADED ACRE 20' /OX OF LOT WIDTH (2 X SIDE SETBACK) 10 ADT PER UNIT X I = 10 ADT 10 ADT PER NURSERY X I = 10 ADT 10 AOT PER UNIT X 17 = '70 ADT 150 ADT WATER SUPPLY SEWER CARLSBAD MUNICIPAL WATER DISTRICT CITY OF CARLSBAD GAS &-ELECTRIC TELEPHONE FIRE POLICE SCHOOLS CABLE S.D.G.&-£ AT&T CITY OF CARLSBAD CITY OF CARLSBAD CARLSBAD UNIFIED SCHOOL DISTRICT TIME WARNER CABLE CONSTRAINTS INFORMATION NO CONSTRNNTS EXIST. SITE HAS BEEN 100 PERCENT D/SnJRBED. ABBREVL4TIONS AC BC BVC aw C&-G CL co DC EC EP EVC FFC fl_ FG GB HP ASPHALT CONCRETE BEGIN CURVE BEGIN VERTICAL CURVE BOTTOM OF WALL CURB AND GUTTER CENTERUNE CLEANOUT DEPRESSED CURB END CURVE EDGE OF PAVEMENT END VERTICAL CURVE FRONT FACE OF CURB F1-0WLINE FINISHED GRADE GRADE BREAK HIGH POINT bl-tA,lnc. land planning, cMI englnoo~ng. surveying 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 IE LT MH NTS PCC PRC RCP RT RW ss SD SDRSD SW TC TW INVERT ELEVATION LEFT MANHOLE NOT TO SCALE POINT OF COMPOUND CURVE POINT OF REVERSE CURVE REINFORCED CONCRETE PIPE RIGHT RIGHT-OF-WAY SANITARY SEl1£R STORM DRAIN SAN DIEGO AREA REGIONAL STANDARD DRAWING SIDEWALK TOP OF CURB TOP OF WALL TENTATIVE MAP ~~ .. -~ MILES PACIFIC .-.~"'i-~ COV~R SJ-fEET .. 't.. .... ' ' ,, -~--... .... ' :'ii, ..,: ... CAR{,SBAD, CA lV.O. 901-1224-400 · SHEET ..L OF _J_ II 0 SEWER DATA NO, BEARING/DEL TA RADIUS LENGTH REMARKS 8 N59'20'00"E 17.40' 8" PVC @I 20% 9 N49"38'24"E 98.34' 8" PVC @I 2.0% 10 N74"54'54"E 108.02' 8" PVC @ 6.5% 11 N89'25'04'W 128.28' 8' PVC @ 5.5% 12 N35"32'27 •w 65.38' 8' PVC @ 2. 0% 13 N0'30'48"E 163.48" 8" PVC @I 2.0% 14 N3374'44"W 179.97' 8" PVC @ 1. 9% K: \land Projects J\901-1224-400\DWG\TM\901-1224-TM02.dwg 7-12-2013 TENTATIVE MAP & COASTAL DEVELOPMENT PLAN 'FOR CT 12-01/PUD 12-08/CDP 12-15 SEESHEETJ CARLSBAD, CA. L_ t EX !fTINl}_(,AS-ll :::::::::--.___ 0 APN 15/f.-351-11 PRQP SED PCC f!!JOW DITCH, D-75 ~', --~ ,. ,_'-.,'· T [L U) <( V tn 0 IS Ix I I ,,,o APN 156-351-17 "-._ ___ ____,,,,, ~AP~ VJ r;.,a-351-19 11"----'"'.J iffiITT'inf:TJi-7~~ -~ ·~ ~/.-:-: ,, .: . . . . .-, ~~~;,--: , , ,:, " n ' s :;,~t :{ " ,': ' : ' ~: ;;;; r:if::D,fcH,, q 75 __, ~T,JY-=; 1~ 'P. ,_ GROSS +I-__j • /'· 9 , j . . 56-351-1 w );:_ I 1/ {I 7.1 LT MJf ~ t'i l,,_,111 " 9' . 8 8.0 ~ :t ,J~ 1 I I PROPOs;f: 6' HIGH :· _:: •c(<f~ :.~<, ' .. , (ASIT F;~ou;_D, -~N} ·, '""-""' .: .f ;< <'-' s '-,, ' >-:<s. :, ' (_) 1 s' o· ~ 30' 60' 90' I iiiiiiiiiiiiiiiiiiiiiiiiii !'!""I ~~~I SCALE: 1 • = 30' REV. DESCRIPTION FIRE NOTES: 1. FIRE ACCESS ROAD SURFACE THE SURFACE OF ALL FIRE DEPARTMENT ACCESS ROUTES SHALL BE OF AN IMPERVIOUS "ALL-WEATHER' SURFACE MATERIAL, DESIGNED TO CARRY A MINIMUM LOAD OF 75, 000 POUNDS AXLE WEIGHT. 2. FIRE LANES. FIRE LANES ARE TO BE DES!GNA TED AND THEY SHALL BECOME THE RESPONSIBILITY OF THE DEvFLOPER TO HA vF SAID ACCESS RESTRICTIONS RECORDED, THAT THE OWNER IS RESPONSIBLE TO PROVIDE AND MAINTAIN TO IDENTIFY, AND ENSURE ENFORCEMENT OF THOSE DESIGNATED ACCESS. J. IN ACCORDANCE wrn-1 CARLSBAD RESIDENT/AL AND FIRE CODES EFFECTlvF JANUARY 1, 2011, ALL RESIDENT/AL PROPERTIES REGARDLESS OF SIZE OR LOCATION NOT PERMITTED FOR CONSTRUCT/ON PRIOR TO JANUARY 1, 2011 SHALL BE PROVIDED mTH AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM. 4. THE CENTER OR THE FURTHEST MOST WALL OR PROJECTION OF THE DWELLING CANNOT EXCEED 150 FEET FROM THE "CENTER-UN£' OF THE NEAREST FIRE DEPARTMENT ACCESS. THIS DISTANCE IS MEASURED ALONG A PATH THAT SIMULATES THE ROUTE A FIREFIGHTER MAY TAKE TO ACCESS ALL PORTIONS OF THE EXTERIOR OF A STRUCTURE FROM THE NEAREST PUBLIC ROAD OF FIRE ACCESS ROAD. 5. PROJECT WILL BE REQUIRED TO INSTALL A ONE INCH (1") OR GREATER WATER SERVICE AND WATER METER. THIS IS TO ENSURE THAT THERE IS ADEQUATE WATER PROVIDED IN THE EVENT OF A FIRE SPRINKLER ACTIVATION DURING PERIODS OF OTHER USES AND/OR DEMANDS, £G. IRRIGATION. NOTE: 28' 18' 5' 2% - PROPOSED 4• AC PVMT OVER 4• AB (MINIMUM) SECTIOND-D STREET A (PR/VA TE) NOT TO SCALE OFF-SITE 5' WIDE SIDEWALK PROPOSED RETAINING WALL - SPLIT FACE BLOCK -TAN EXISTING GROUND SUMMARY TABLE LOT LOT LOT SETBACKS SIZE SF WIDTH FRONT INT. SID£ STREET SIDE REAR 1 11,942 138 20 10 10 20 2 13,626 105 20 10 10 20 3 11,909 60 20 6 70 12 4 11,238 114 20 10 10 20 5 10,190 60 20 6 10 12 6 10,149 60 20 6 10 12 7 9,088 60 20 6 70 12 8 8,007 60 20 6 10 12 9 10,017 60 20 6 70 12 10 10,080 60 20 6 10 12 11 10,130 60 20 6 70 12 12 9,005 102 20 10 10 20 13 9,312 92 20 9 10 19 14 9,571 81 20 8 10 17 15 9,411 81 15 8 10 17 76 7,509 80 20 8 70 16 17 8,662 13 20 7 10 15 NOTES: • MINIMUM LOT SIZE IS 7,500 S.F. • LOT WIDTH IS 60 FEET MIN. (MEASURED A FRONT YARD SETBACK} • FRONT YARD SETBACK IS 20' • SIDE YARD SETBACK EQUAL TO 10:f OF LOT WIDTH (MIN. 5' AND NEED NOT £EXCEED 10'} • STREET SIDE YARD SETBACK IS 70' • STREET •a• IS A DR/vF AISLE :it LOT 15 IS A KEY LOT (15' FRONT YARD SETBACK) • ALL SOUND WALLS TO BE SPLIT FACE BLOCK -TAN ___ ...,....__ IND/CA TES LOCATION OF SPLIT FACE BLOCK SOUND WALL ALL SIDE YARD AREAS SHALL HA VE 6 FOOT FENCING. SOUND WALL LOCATION SCALE: I•=10o' DATE APPD bl-t~lnc. land planning, cMI englnoo~ng, surveying 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 TENTATIVE MAP MILES PACIFIC PLAN VIEW CARLSBAD, CA JV.O. 901-1224-400 SJIEET ..L OF J_ TENTATIVE MAP & COASTAL DEVELOPMENT PLAN FOR CT 12-01/PUD 12-08/CDP 12-15 CATCH BASIN TYPE F PER D-7 X=4: Y=4: V=6.15: T=6" MANHOLE FRAME AND COVER PER M-2~ DEEP ROOTED, DENSE, DROUGHT TOLERANT PLANT/NG SUITABLE FOR flf"LL DRAINED SOIL DEEP ROO TEO, DENSE. DROUGHT TOLERANT PLAN TING SUI TABLE FOR CARLSBAD} CA. 12" PVC OUn.ET PIPE 12" PVC INLET PIPE FROM CATCH BASIN 36" -6.13' 85.77' 84.64' RESTRICTOR PLATE TO LIMIT FLOW FROM V2 STORAGE AREA, 0.9" DRAIN DOWN HOLE ) TW 85.50' 18" ENGINEERED SOIL MIX 2' V2 STORAGE LA YER, 3/4" CRUSHED ROCK 4• PERFORATED PVC UNDERDRAIN PIPE Pl.ACE PIPE WITH PERFORATIONS AT THE INVERT IMPERMEABLE LINER THROUGHOUT BIO RETENTION SECTION DETAIL: BASINA NOT TO SCALE 12" PVC OUn.ET PIPE WELL DRAINED SOIL 85.89' 83.84' ) TW 84.60' ,.-,.,,_..., 18" ENGINEERED 6.09' ·-... ' .. 78.50' ~t7fl.~~O!!~..._~'""'-s;;"--......,'8.:'G_';'f,,~~;;!!;;~~cW.. SOIL MIX 2' V2 STORAGE LA YER, 3/4" CRUSHED ROCK 4" PERFORATED PVC UNDERDRAIN PIPE PLACE PIPE WITH PERFORATIONS AT THE INVERT RESTRICTOR PLATE TO LIMIT FLOW FROM V2 STORAGE AREA, 1. o• DRAIN DOWN HOLE IMPERMEABLE LINER THROUGHOUT BIO RETENTION SECTION DETAIL: BASINB NOT TO SCALE SEESHEET2 I -.. ½fJf;-31---~@~-~I-- I LOFf- FE=~---2,,~~:___----11 IB~ ~' .. OT12~<{ PE94. l MH 5 V _.......--\I _-._v " ½ , 9§.a. € -~ 0 156-351 HI~ 'N~ WAI# -T, ~g _,-yy 0 g 0 :Ji N 0 PROPOSED 6' HIGH MASONRY SOUND WALL (SLUMP STONE-TAN) 2.0' ,-1111 I-2: 1 SLOPE 2: 1 SLOPE LOT 8 PAD EL: 87.5 \-,Ll',1~.13------~ li!.I INSTALL MASONRY "> a.':l· EXIST/NG =-_ UND , r 18" ENGINEERED MATERIAL O BASIN RETAINING WALL u \'41 IMPERMEABLE LINER SECTION A-A NOT TO SCALE o_ K: \Land Projects J\901-1224-400\DWG\!M\901-124-TMOJ.dwg 7-12-2013 J1----t-t ---::_.:-_---i---- NOTE: " BASIN "dj &-"B" DETENT/QN &-STORMWA TER MANAGEMENT BASINf"TO' BE MAINTAINED B H.O.A. 168'+ - OJ DESCRIPTION PROPOSED 6' HIGH MASONRY SOUND WALL (SPLIT FACE BLOCK-TAN} 20' 1110£ 2.0· I PUBLIC SEWER EASEMENT TOP 90.0 I-PROPOSED 6' HIGH CHA/Nl/NK FENCE '1>1~ .... LOT 9 Ci,· PAD EL: 88.0 SEE DETAIL ABOVE FOR STORM DRAIN DATE APPD \~ PROPOSED MASONRY RETAINING WALL I', NOTE: ALL SIDE YARD AREAS SHALL HA VE 6 FOOT FENCING. NO. BEARING/DEL TA RADIUS LENGTH RF:MARKS 1 N41'38'31"W 16.51' 8" PVC@ 0.40% 2 48.72' 8" PVC @ 0.40% 3 N37'39'14 "W 240.18' 8" PVC @ 0.40% 4 N34'27'04"W 155.33' 8• PVC @ 0.40% 5 N00'29'38"E 154.31' 8" PVC @ 0.40% 6 N89'30'22"W 98.53' 8" PVC @ 0.40% 7 N89'30'22"W 208.44' 8" PVC @ 1.00% b~A,lnc. W' SE',fER -owe, 155_9 TO~ WER MOVE 7Vll-.H. ID RI · 8 .35 · (\J CD X 10' SEl1£ / I i---CALTRANS R/W 85-------------2-t_-i~E~SM~T.~. -83-.2--------85 PROPOSED ----~-..:..._,~ f'G. OFFSITE GRADi'f.i(; --. ..___ SO-PROPOSED 8 SE~ , ,, iLJM/ EXIST/NG PCC 0 BROWDITClt---oO \ . -.. .. --~~%fJJ!:% \ 75---SEeTION:'e--FJL--------~ -75 SCAL[: HORIZ.: 1"=20' VER r.: 1 •=4' 30' 15' o' 30' 60' 90' SCALE: 1" = 301 ~VESS[ RONALD J. HOLLOWAY NO. 29271 land planning, cMI englnooi!ng, surveying TENTATIVE MAP MILES PACIFIC PLAN VIEW C[VU, 5115 AVENIDA ENCINAS SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 CARLSBAD, CA WO. 901-1224-400 SHEET_}_ OF J_ X78.6 X79,3 ----B 0--..._ X81.2 X77,7 X81.4 K: \land Projects 3\901-1224-400\DWG\TM\901-124-TIJ04dwg 7-12-20/J X84.7 X82.6 -·----- ~ \ f. 1$ '/{Ci ~~ , ·,~c-:,,.; ' TENTATIVE MAP & COASTAL DEVELOPMENT PLAN FOR CT 12-01/PUD 12-08/CDP 12-15 9>1.0 X87.7 OBSCUR~D CARLSBAD, CA. V 0 ~ Oo 0 0 "' 0 0 99,7 0 8 .o 1 r', X ---.cc ~ 1J2.7 ' ' . "' "' rri ~ ·< X116.7 [-. '"'·' r-,--X-->!9-4.4,~..,,._----~.....,._'""'v"'......,,..l---..,,........,,..---.,...L,._~~~~~-.d:..,,:,,,~_b..J~_ ~ [,'l"---~l EXISTING FENCE TO BE REMOVED ~-- [ ~ c~I----,,,.,,,--=-~ . ~ . -£XI Tlt{f Jfis1DENCE \ ~ ----r,G. '. (TO Bt.-(f MO\,f'D)m . --~-EXISTING GR££ OUSE -TO 8£ REMO\,f'~•-,c--\ i "i(ISTING ' -I '-' I AREA O/3SCURED BY ShAD CLOTH \ \ \ EXIST. PO'M:R POLE / ?221964 -TO BE REMOVED fENHOUSE -TO BE REMOVED----'s'~----. AREA OB CURED BY SHADECLOTH \ X98.4 ,Ori £ /ST. POWER POLE .P!f21963 -TO BE' EMO\.£DJ0.5 110.9 EXISTIN,G SH£ - TO BE ~EMO D \ 1 1211-.5 r REV. DESCRIPTION I Vt,ILIT/ES ~. 8£ .. . EXIST/ ~ 1.1 Ii! p VA 7F <fMO\,f'D 1 . . Ace£ S.fASEMEN. TPER F/P . <AID-· y"'( ,,.,._....,, , 93-0 59431 Of._9.R. ,,,., ,,., l ( 0 110.2 DATE APPD 125,Q " ':J! I 4.6 ~, I I 12.0.4 b~A,lnc. (]) NOTE: ALL EX/STING FENCES AROUND PROPER TY (EXCEPT FOR CAL TRANS CHA/NL/NK FENCE} TO BE REMOVED & RECONSTRUCTED WITH THE APPROVAL & COOPERATION OF ALL ADJACENT PROPERTY OWNERS. 2D' D' 4D' BO' 12D' ~~~~liiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii '~~~I SCALE: 1" ; 4D' RONALD L. HOLLOWAY NO. 29271 k::md planning, clvl anglneoong, suNeylng TENTATIVE MAP MILES PACIFIC DEMOLITION PLAN l']VI\, 5115 AVENIDA ENCINAS SUITE "L • CARLSBAD, CA. 9200B-4387 (76D) 931-87D0 CARLSBAD, CA w.o. 901-1224-400 SHEET _L OF J_ , PL 12· ' ' -----'---...a BJ.4 EX. GRD. -----: -I ' -·-· EX/SllNG GRADE X81.2 PROPOSED LOCA 77ON OF ALL 2. O' REMOVED CONTAMINA JED MA 1tRIAL -: I • ---- K: \Land Projects 3\901-1224-400\DWG\ TM\901-124-TM05.dwg 7-12-2013 X 81.4 92.8 EX. GRD. ------ ' ' ; I I TENTATIVE MAP & COASTAL DEVELOPMENT PLAN FOR X87.7 CARLSBAD, CA. ~H \ l~wl b=\IJ_(s) u: ' L,) ~(9i3) ~ . ---- -' ,71.9 FG ', AREA OSSCURED BY SHAD. CLOTH X94.4 \ 10"1,5_ ASPH. " ' d? X82.6 \2~.l> ll------'---'-,----+---'-~~~-=G=---"'' \+,-----------;" "j X98.4 ,7 ( 1: 1 SLOPE I .71.9 /r ', 91.6 EX. GRD. ~ 97.5 EX. GRD. ''1'.>< La,---~------;~~~rtf"l -_ I" 8.4 \ c;('-0; "'' X\02 7 A= I ' •· -·· I '----I , ____ , 2' REMOVAL OF ALL CONTAM/NA JED MA 1tRIAL TOXAPHENE \ = 7.LQ,/ FG 1: 1 SLOPE BOTTOM ELEV: 7 .0 AREA OB C ED fJ';OSHJ,DECLOTH 72_4 i r ·-__ . 1:1_ SLOPE ~ I ---------. ------- ~-- EX/SllNG GRADE --' ---' ---·· I __ , __ _ I .,. -' ' ! --··- ' ----' ' FG BOT\ ELEV: 78,8 PL ---: 1----' 1------! : ··.:~----_ i ' : _·_-_:. ! i I ------. ,---- -· ---I ; -_ :-~~ i I --=----~ --! , __ ' J -[>',/SPH. U~ ... TI 93:l EX/ GRD. ' j ASPH. ---,___----ll- X 116,7 REV. DESCRIPTION DAJE APPD b~A,lnc. CT 12-01/PUD 12-08/CDP 12-15 " i t TOTAL GRADED AREA: EARTHWORK: TOXAPHERE MATERIAL: NOTE: 2.89 ACRES 59,300 CY 17,500 CY SEE LIMITED PHASE II A GR/CULTURAL SURVEY, PREPARED BY GEOSOILS, INC. DATED: 8-4-2011, AS W.O. £6211.1-SC SCALE: 1 " ~ 40' TENTATIVE MAP RONALD HOLLOW NO. 292 land planning, civil engineering. surveying -I ;---·---5115 AVENIDA ENCINAS MILES PACIFIC REMEDIAL GRADING EXHIBIT TOXAPHENE REMOVAL & REPIACEMENT ·-I I -·-: :~~=~ i l ---' , ___ ! ; ----1 ! _____ _ --, I • -I •• ·-J I ' I ' SECTION 'E-E' SCALE: HORIZ: I•= 40' VERT: 1"=8' l'IVI SUITE "L" CARLSBAD, CA. 92008-4387 (760) 931-8700 CARLSBAD, CA WO. 901-1224-400 SHEET _J_ OF _J_