Loading...
HomeMy WebLinkAboutPD 2022-0007; HAGUE RESIDENCE; SOILS REPORT-RESPONSE TO COMMENTS; 2022-09-06 EDG Project No. 216614-1 Date: September 6th, 2022 To: Ms. Nichole Fine City of Carlsbad Land Development Engineering 1635 Faraday Avenue Carlsbad, California 92008-7314 Re: Proposed new, single-family residence, to be constructed at Cynthia Lane (APN:156-231- 70), Carlsbad, California Subject: Addendum No. 2 – Updated Recommendations and Response to Comments. EDG Project: 216614-1 Project ID: PD2022-0007 Grading No. GR2022-0011 References: 1. “Preliminary Geotechnical Investigation and Recommendations Proposed, New Single-Family Residence to be located at Cynthia Lane (APN:156-231-70), Carlsbad, California”, prepared by Engineering Design Group, dated October 18th, 2021. 2. “Addendum No. 1 – Updated Recommendations and Response to Comments”, prepared by Engineering Design Group, dated August 26, 2022. 3. Geotechnical Report Review, Hague Residence – Cynthia Lane, Carlsbad, California (2nd Review), dated August 5, 2020. From City of Carlsbad – Land Development Engineering. 4. Engineering Design Group, Grading Plan for Hague Residence– APN: 260-213-13, dated August 2022. 1.0 PURPOSE We have prepared this addendum to provide updated recommendations to the above referenced preliminary geotechnical report and addendum No. 1 (Reference No. 1 and No. 2, respectively) based upon the updated preliminary grading plans (Reference No. 4), for the proposed new, single-family residence, to be located at Cynthia Lane (APN: 156-231-70), in the City of Carlsbad. This addendum will ENGINEERING DESIGN GROUP www.designgroupca.com 2121 Montiel Road, San Marcos, CA 92069 760.839.7302 EDG Project No. 216614-1 also address City of Carlsbad – Land Development Engineering Department’s – Geotechnical Report Review comments (Reference No. 3). The response to comments will be incorporated into this Addendum. 2.0 GEOLOGY AND FAULTS – RESPONSE TO COMMENT NO. 1 As described in Addendum No. 1, the project site is located within the Peninsular Ranges Geomorphic Province of California. Site area topography consists of coastal foothill terrain and relatively shallow drainages. The site is underlain by late-to-middle, Pleistocene-era, paralic deposits (as mapped per Kennedy, et.al., 2007). The nearest mapped active fault (Holocene) is the Rose Canyon Fault (Newport-Inglewood Fault zone) in the Offshore Zone of Deformation, located approximately 22 miles southwest of the subject site. Other major mapped faults in the region are the Elsinore Fault and associated faults within the Elsinore zone, and the San Jacinto Fault and related branches within the San Jacinto zone. The subject site is approximately 24 miles southwest from the Elsinore Fault zone and approximately 48 miles west from the San Jacinto Fault zone. Our review of geologic literature pertaining to the general site area indicates the subject site is not within a mapped Alquist-Priolo fault zone. It is our opinion that the site could be subjected to moderate to severe ground shaking in the event of a major earthquake along any of the faults in the Southern California region. The seismic risk at this site is similar to that of the surrounding developed area. 3.0 SOIL TYPE AND VALUES – RESPONSE TO COMMENT NO. 2 During our subsurface investigation, penetrometer readings were taken within our test pits. Readings from our tests, indicate onsite soils posses an unconfined compressive strength of between 2.0 and 3.0 tons per square foot. Based upon onsite testing, observation of onsite soils and our experience, a conservative value of 2,000 PSF for bearing capacity was provided in our original report. 4.0 SITE CLASS – RESPONSE TO COMMENT NO. 3 For clarification purposes, we have provided the following values corresponding to Site Class D. Site Class D* Seismic Design Category D* ASCE 7-16 Seismic Design Parameters SS (g) 1.048 S1 (g) 0.381 SMS (g) 1.133 EDG Project No. 216614-1 SDS (g) 0.755 *Using the code values provided in the table above rather than performing a ground motion hazard analysis, requires the exception identified in ASCE section 11.4.8 be utilized in the structural design. All recommendations and design parameters from our original report, not discussed herein, remain applicable. If you have any questions regarding this letter, please feel free to contact our office. Sincerely, ENGINEERING DESIGN GROUP Erin E. Rist RCE #65122 Steven Norris GE 2590; CEG 2263 2590 Exp 12-31-23