Loading...
HomeMy WebLinkAboutSUP 2022-0001; OMNI LA COSTA GOLF COURSE; LIMITED GEOTECHNICAL INVESTIGATION; 2021-04-15LIMITED GEOTECHNICAL INVESTIGATION CHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA PREPARED FOR TRT HOLDINGS, INC. DALLAS, TEXAS APRIL 15, 2021 PROJECT NO. T2754-22-04 Project No. T2754-22-04 April 15, 2021 Mr. Clint Gulick TRT Holdings, Inc. 4001 Maple Avenue, Suite 600 Dallas, Texas 75219 Subject: LIMITED GEOTECHNICAL INVESTIGATION CHAMPIONS COURSE RENOVATIONS ONMI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA Dear Mr. Gulick: In accordance with your authorization of the work order authorization dated February 17, 2021, Geocon West Inc. (Geocon) herein submits the results of our limited geotechnical investigation for the subject site. The accompanying report presents the results of our study and conclusions and recommendations pertaining to the geotechnical aspects of the proposed golf course renovations. The site is considered suitable for development provided the recommendations of this report are followed. Should you have questions regarding this report, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, GEOCON WEST, INC. Paul D. Theriault CEG 2374 Joseph E. Vettel GE 2401 PDT:JJV:hd (e-mail) Addressee (Clint.Gulick@Omnihotels.com) GEOCON W E S T, I N C. GEOTECHNICA L ■ ENVIRONMENTAL • MATE RI ALSO 41571 Corning Ploce, Suite l 01 ■ Murrieto, Colilornio 92562-7065 ■ Telephone 951.304.2300 ■ Fox 951 .304.2392 Geocon Project No. T2754-22-04 - i - April 15, 2021 TABLE OF CONTENTS 1. PURPOSE AND SCOPE ...................................................................................................................... 1 2. SITE AND PROJECT DESCRIPTION ................................................................................................ 1 3. GEOLOGIC SETTING ......................................................................................................................... 2 4. SOIL AND GEOLOGIC CONDITIONS ............................................................................................. 2 4.1 Undocumented Fill (afu) ............................................................................................................. 2 4.2 Young Alluvial Deposits (Qya) .................................................................................................. 2 5. GROUNDWATER ............................................................................................................................... 3 6. GEOLOGIC HAZARDS ...................................................................................................................... 3 6.1 Faulting ....................................................................................................................................... 3 6.2 Ground Rupture .......................................................................................................................... 5 6.3 Liquefaction ................................................................................................................................ 5 6.4 Expansive Soil ............................................................................................................................ 5 6.5 Seiches and Tsunamis ................................................................................................................. 5 6.6 Inundation ................................................................................................................................... 5 6.7 Landslides ................................................................................................................................... 6 6.8 Rock Fall Hazards....................................................................................................................... 6 6.9 Slope Stability ............................................................................................................................. 6 7. CONCLUSIONS AND RECOMMENDATIONS ................................................................................ 7 7.1 General ........................................................................................................................................ 7 7.2 Excavation and Soil Characteristics ........................................................................................... 8 7.3 Seismic Design Criteria ............................................................................................................ 10 7.4 Temporary Excavations ............................................................................................................ 12 7.5 Grading ..................................................................................................................................... 12 7.6 Earthwork Grading Factors ....................................................................................................... 14 7.7 Foundation and Concrete Slab-On-Grade Recommendations .................................................. 14 7.8 Concrete Flatwork .................................................................................................................... 15 7.9 Conventional Retaining Walls .................................................................................................. 16 7.10 Lateral Loading ......................................................................................................................... 18 7.11 Preliminary Pavement Recommendations ................................................................................ 18 7.12 Site Drainage and Moisture Protection ..................................................................................... 20 7.13 Grading and Foundation Plan Review ...................................................................................... 21 LIMITATIONS AND UNIFORMITY OF CONDITIONS LIST OF REFERENCES TABLE OF CONTENTS (Concluded) Geocon Project No. T2754-22-04 - ii - April 15, 2021 MAPS AND ILLUSTRATIONS Figure 1, Vicinity Map Figure 2, Boring Location Map Figure 3, Wall/Column Footing Detail Figure 4, Typical Retaining Wall Drain Detail APPENDIX A FIELD INVESTIGATION Figures A-1 through A-6, Logs of Borings (Geocon, this report) Figures A-7 through A-14, Logs of Borings (Geocon, 2002) APPENDIX B LABORATORY TESTING Figure B-1, Laboratory Test Results Figure B-2, Direct Shear Test Results Figures B-3 and B-4, Laboratory Test Results (Geocon, 2002) APPENDIX C RECOMMENDED GRADING SPECIFICATIONS Geocon Project No. T2754-22-04 - 1 - April 15, 2021 LIMITED GEOTECHNICAL INVESTIGATION 1. PURPOSE AND SCOPE This report presents the results of our limited geotechnical investigation for the renovations planned at the Champions Course at the Omni La Costa Resort & Spa, located at 2100 Costa Del Mar Road, Carlsbad, California as depicted on the Vicinity Map, Figure 1. The purpose of the limited geotechnical investigation is to evaluate the surface and subsurface soil conditions and general site geology, and to identify geotechnical constraints that may affect the proposed renovations. In addition, we provided recommendations for remedial grading, shallow foundations, concrete flatwork, rigid pavement, and retaining walls. This investigation also included a review of readily available published and unpublished geologic literature (see List of References). The scope of this investigation included performing a site reconnaissance, field exploration, engineering analyses, and preparing this report. We performed our field investigation on March 15, 2021, by drilling two small-diameter borings to a maximum depth of approximately 20 feet below the existing ground surface and advancing four hand auger borings to depths of approximately 5 feet below the existing ground surface. The Boring Location Map, Figure 2, presents the approximate locations of the borings. Appendix A provides a detailed discussion of the field investigation including logs of the borings including boring logs from our 2002 geotechnical investigation (Reference 18). Details of the laboratory tests and a summary of the test results are presented in Appendix B and on the boring logs in Appendix A as well as laboratory data from our 2002 geotechnical investigation. Recommendations presented herein are based on analyses of data obtained from our site investigation and our understanding of proposed site development. If project details vary significantly from those described herein, Geocon should be contacted to evaluate the necessity for review and possible revision of this report. 2. SITE AND PROJECT DESCRIPTION The subject site is the Champions Golf Course, part of the Omni La Costa Resort and Spa’s 36 hole, two-course system, located at 2100 Costa Del Mar Road, Carlsbad, California. The Champions Course generally runs in a north-south direction and is east of El Camino Real, south of Poinsettia Lane and north of La Costa Avenue. The Course consists of an 18-hole, variable elevation course, with existing tee boxes, cart paths, water hazards, sand traps, fairways and greens over and approximately 7,172-yard distance (black tees). Based on a review of the Conceptual Plans prepared by Hanse Golf Course Design, Inc., we understand that the proposed renovations will consist of adding and removing hazards, reshaping Geocon Project No. T2754-22-04 - 2 - April 15, 2021 fairways and greens, realigning carts paths, adding a retaining wall near the 18th green, and foot bridges spanning a creek between the 1st and 15th holes. The site descriptions and proposed development are based on a site reconnaissance, review of published geologic literature, our field investigation, a review of the conceptual plan, and discussions with you. 3. GEOLOGIC SETTING The site is located on wave cut platforms west of the Santa Ana Mountains within the Peninsular Ranges Geomorphic Province (Province). In the vicinity of the site, the Province is characterized by sandstone deposits on regionally uplifted wave cut platforms which display elevated erosional surfaces surrounded by alluvium-filled valleys. The Santa Ana Mountains Block is characterized by heterogeneous granitic bedrock with a moderate amount of volcanic and metamorphic rocks, and some terrestrial sedimentary rocks. The Peninsular Ranges are bound by the Transverse Ranges (San Gabriel and San Bernardino Mountains) to the north and the Colorado Desert Geomorphic Province to the east. The Peninsular Ranges Geomorphic Province extends westward into the Pacific Ocean and southward to the tip of Baja California. Overall, the Province is characterized by Cretaceous-age granitic rock and a lesser amount of Mesozoic-age metamorphic rock overlain by terrestrial and marine sediments. Faulting within the Province is typically northwest trending and includes the San Andreas, San Jacinto, Elsinore, Newport-Inglewood and Rose Canyon faults. 4. SOIL AND GEOLOGIC CONDITIONS We observed undocumented fill and young alluvial deposits during our field investigation. The description of the geologic units encountered are shown on the boring logs in Appendix A. The surficial soil and geologic units are described herein in order of increasing age. 4.1 Undocumented Fill (afu) Undocumented Fill was encountered in all of the borings to depths ranging from one-half to one foot and consisted of fine sandy clay that was damp to moist, stiff, dark brown; and silty fine to medium sand that was damp, medium dense, and brown. Varying amounts of mica were observed in the undocumented fill. 4.2 Young Alluvial Deposits (Qya) Young Alluvial Deposits were encountered beneath the undocumented fill in all the borings to the maximum depth drilled and consisted of sandy clay that was moist to saturated, stiff, dark brown with varying amounts and size of sand to clayey fine to coarse sand that was saturated, medium dense to silty sand that was moist, medium dense, and brown. Geocon Project No. T2754-22-04 - 3 - April 15, 2021 5. GROUNDWATER Groundwater was encountered in borings B-1 and B-2 at depths of 7.2 and 8.0 feet below the ground surface, respectively. It is not uncommon for seepage conditions to develop where none previously existed. Groundwater and seepage are dependent on seasonal precipitation, irrigation, land use, among other factors, and varies as a result. Proper surface drainage will be important to future performance of the planned improvements. 6. GEOLOGIC HAZARDS 6.1 Faulting The numerous faults in southern California include active, potentially active, and inactive faults. The criteria for these major groups are based on criteria developed by the California Geological Survey (CGS, formerly known as CDMG) for the Alquist-Priolo Earthquake Fault Zone Program (Bryant and Hart, 2007). By definition, an active fault is one that has had surface displacement within Holocene time (about the last 11,700 years). A potentially active fault has demonstrated surface displacement during Quaternary time (approximately the last 1.6 million years) but has had no known Holocene movement. Faults that have not moved in the last 1.6 million years are considered inactive. The site is not within a currently established State of California Alquist-Priolo Earthquake Fault Zone or a San Diego County Safety Study Hazard Zone for surface fault rupture hazards. No active or potentially active faults with the potential for surface fault rupture are known to pass directly beneath the site. Therefore, the potential for surface rupture due to faulting occurring beneath the site during the design life of the proposed school is considered low. However, the site is located in the seismically active southern California region, and could be subjected to moderate to strong ground shaking in the event of an earthquake on one of the many active southern California faults. According to the Fault Activity Map of California (2010), 7 known active faults are located within a search radius of 62 miles from the property. The nearest known active fault is Newport-Inglewood Fault Zone located approximately 5.7 miles west of the site, and is the dominant source of potential ground motion. Earthquakes that might occur on these fault zones or other faults within the southern California and northern Baja California area are potential generators of significant ground motion at the site. Table 6.1.1 lists the estimated maximum earthquake magnitude for the most dominant faults in relationship to the site location. Geocon Project No. T2754-22-04 - 4 - April 15, 2021 TABLE 6.1.1 SIGNIFICANT ACTIVE FAULTS WITHIN 100 KM OF THE SITE Fault Direction Distance from Site (Miles) Magnitude Newport-Inglewood WSW 5.7 7.1 Coronado Bank WSW 20.3 7.2 Elsinore NE 22.9 6.8 San Diego Trough WSW 31.3 7.2 San Jacinto NE 49.8 6.9 Casa Loma NE 47.6 6.9 Rose Canyon S 60.1 7.2 Historic earthquakes in southern California of magnitude 6.0 and greater, their magnitude, distance, and direction from the site are listed in Table 6.1.2. TABLE 6.1.2 HISTORIC EARTHQUAKE EVENTS WITH RESPECT TO THE SITE Earthquake Date of Earthquake Magnitude Distance to Epicenter (Miles) Direction to Epicenter (Oldest to Youngest) San Jacinto April 21, 1918 6.8 48 NNE Loma Linda Area July 22, 1923 6.3 63 N Long Beach March 10, 1933 6.4 54 NW Buck Ridge March 25, 1937 6.0 62 ENE Imperial Valley May 18, 1940 6.9 88 NE Desert Hot Springs December 4, 1948 6.0 77 NE Arroyo Salada March 19, 1954 6.4 70 E Borrego Mountain April 8, 1968 6.5 72 E San Fernando February 9, 1971 6.6 115 NW Joshua Tree April 22, 1992 6.1 85 NE Landers June 28, 1992 7.3 93 NE Big Bear June 28, 1992 6.4 81 NNE Northridge January 17, 1994 6.7 111 NW Hector Mine October 16, 1999 7.1 121 NE Geocon Project No. T2754-22-04 - 5 - April 15, 2021 6.2 Ground Rupture Ground surface rupture occurs when movement along a fault is sufficient to cause a gap or rupture where the upper edge of the fault zone intersects the earth’s surface. The potential for ground rupture is considered to be very low due to the absence of active or potentially active faults at the subject site. 6.3 Liquefaction Liquefaction is a phenomenon in which loose, saturated, relatively cohesionless soil deposits lose shear strength during strong ground motions. Primary factors controlling liquefaction include intensity and duration of ground motion, gradation characteristics of the subsurface soils, in-situ stress conditions, and the depth to groundwater. Liquefaction is typified by a loss of shear strength in the liquefied layers due to rapid increases in pore water pressure generated by earthquake accelerations. The proposed retaining wall and foot bridges will be built on alluvial soils and liquefaction may be a design consideration. 6.4 Expansive Soil Previous work at the site (Geocon, 2017) has indicated that a “medium” expansion potential with expansion indices of 74 and 78 as defined by ASTM D4829. 6.5 Seiches and Tsunamis A seiche is a run-up of water within a lake or embayment triggered by fault- or landslide-induced ground displacement. Batiquitos Lagoon is located approximately 2,000 feet west of the site. However, due to an elevation gain of approximately 20 feet towards the site and the shallow nature of the eastern portion of the lagoon, seiches are not a design consideration for the site. A tsunami is a series of long period waves generated in the ocean by a sudden displacement of large volumes of water. Causes of tsunamis include underwater earthquakes, volcanic eruptions, or offshore slope failures. The first order driving force for locally generated tsunamis offshore southern California is expected to be tectonic deformation from large earthquakes (Legg, et al., 2003). Although the site is located 2.8 miles from the coast, and 2,000 feet from the mouth of the Batiquitos Lagoon, a Tsunami Inundation Map for Emergency Planning prepared by the California Emergency Management Agency indicates the site is not within a tsunami inundation zone; therefore, risk associated with tsunamis is not a design consideration. 6.6 Inundation According to the State of California, Department of Water Resources, Inundation Map for San Marcos Dam, dated November 26, 1973, the site is within an inundation zone due to dam failure of the San Marcos dam, and the California Department of Water Resources, Division of Safety of Dams (DSOD), the site is within an inundation zone for the Stanley A. Mahr Reservoir. Geocon Project No. T2754-22-04 - 6 - April 15, 2021 6.7 Landslides There are no steep slopes on or adjacent to the site. Therefore, landslides are not a design consideration for the site. 6.8 Rock Fall Hazards Rock falls are not a design consideration due to the lack of natural bedrock slopes above and adjacent to the site. 6.9 Slope Stability Based on the preliminary site plan and relatively flat site topography, it does not appear that significant slopes will be constructed. Therefore, slope stability will not be a design consideration for the site. Geocon Project No. T2754-22-04 - 7 - April 15, 2021 7. CONCLUSIONS AND RECOMMENDATIONS 7.1 General 7.1.1 Neither soil nor geologic conditions were encountered during the investigation that would preclude construction of the proposed project provided the recommendations presented herein are followed and implemented during design and construction 7.1.2 Potential geologic hazards at the site include seismic shaking, liquefaction and seismic settlement, and expansive soils. Based on our investigation and available geologic information, active, potentially active, or inactive faults are not present underlying or trending toward the site. 7.1.3 Our field investigation indicates the site consists of undocumented fill underlain by young alluvial deposits. Undocumented fill and the upper portion of the alluvial soils are not considered suitable for the support of compacted fill and settlement-sensitive structures. Remedial grading of the surficial soil will be required as discussed herein. The existing site soils are suitable for re-use as engineered fill provided the recommendations in the Grading section of this report are followed. 7.1.4 Moisture contents in the borings were generally high. Drying back of overly wet soils or importing of dryer material should be expected during construction. 7.1.5 Due to the high moisture content, caving in unshored excavations should be expected at the site. It is the responsibility of the contractor to ensure that excavations and trenches are properly shored and maintained in accordance with OSHA rules and regulations to maintain the stability of adjacent existing improvements. 7.1.6 The laboratory tests on soils near the site indicate that the site soils are expansive and have a “medium” expansion potential. If highly expansive soils are encountered in areas where deformation sensitive improvements are planned, they should be exported from the site or selectively graded and placed in the deeper fill areas to allow for the placement of low to medium expansion material at the finish pad grade. 7.1.7 – Water soluble sulfate concentrations indicate Exposure Class S1 and S2 and will therefore require Type II or Type V cement. 7.1.8 Groundwater was encountered at 7.2 and 8.0 feet below the existing ground surface in borings B-1 and B-2, respectively. Groundwater could impact site improvements. Geocon Project No. T2754-22-04 - 8 - April 15, 2021 7.1.9 The planned structures can be supported on a shallow foundation system with a slab-on- grade floor system. 7.1.10 Changes in the design, location or elevation of improvements, as outlined in this report, should be reviewed by this office. Once final grading plans become available, they should be reviewed by this office to evaluate the necessity for review and possible revision of this report. 7.1.11 Recommended grading specifications are provided in Appendix C. 7.2 Excavation and Soil Characteristics 7.2.1 Excavation of the in-situ soils can be excavated with moderate effort using conventional excavation equipment. Some caving should be anticipated in unshored excavations, especially where saturated soils are present. 7.2.2 It is the responsibility of the contractor to ensure that excavations and trenches are properly shored and maintained in accordance with applicable OSHA rules and regulations to maintain safety and the stability of existing adjacent improvements. 7.2.3 Onsite excavations must be conducted in such a manner that potential surcharges from existing structures, construction equipment, and vehicle loads are resisted. The surcharge area may be defined by a 1:1 projection down and away from the bottom of an existing foundation or vehicle load. Penetrations below this 1:1 projection will require special excavation measures such as sloping or shoring. Excavation recommendations are provided in the Temporary Excavations section of this report. 7.2.4 The soil encountered in the field investigation is considered to be “expansive” (expansion index [EI] of greater than 20) as defined by 2019 California Building Code (CBC) Section 1803.5.3. Table 7.2.4 presents soil classifications based on the expansion index. Based on the laboratory test results of nearby soils, we expect a majority of the soil encountered will possess a “medium” expansion potential (EI between 0 and 20). If highly expansive soils are encountered at the site, they should not be placed within 4 feet of the proposed foundations, flatwork or paving improvements. Additional testing for expansion potential should be performed during grading and once final grades are achieved. Geocon Project No. T2754-22-04 - 9 - April 15, 2021 TABLE 7.2.4 EXPANSION CLASSIFICATION BASED ON EXPANSION INDEX Expansion Index (EI) ASTM D 4829 Expansion Classification 2019 CBC Expansion Classification 0 – 20 Very Low Non-Expansive 21 – 50 Low Expansive 51 – 90 Medium 91 – 130 High Greater Than 130 Very High 7.2.5 We performed laboratory tests on samples of the site materials to evaluate the percentage of water-soluble sulfate content. Appendix B presents results of the laboratory water-soluble sulfate content tests. The test results indicate the on-site materials at the location tested possess a sulfate content of 0.100 to 1.390 percent (1,002 to 13,390 parts per million [ppm]) equating to an exposure class of “S1” to “S2” as defined by 2019 CBC Section 1904.3 and ACI 318. Table 7.2.5 presents a summary of concrete requirements set forth by 2019 CBC Section 1904.3 and ACI 318. The presence of water-soluble sulfates is not a visually discernible characteristic; therefore, other soil samples from the site could yield different concentrations. Additionally, over time landscaping activities (i.e., addition of fertilizers and other soil nutrients) may affect the concentration. TABLE 7.2.5 REQUIREMENTS FOR CONCRETE EXPOSED TO SULFATE-CONTAINING SOLUTIONS Exposure Class Water-Soluble Sulfate (SO4) Percent by Weight Cement Type (ASTM C 150) Maximum Water to Cement Ratio by Weight1 Minimum Compressive Strength (psi) S0 SO4<0.10 No Type Restriction n/a 2,500 S1 0.10<SO4<0.20 II 0.50 4,000 S2 0.20<SO4<2.00 V 0.45 4,500 S3 SO4>2.00 V+Pozzolan or Slag 0.45 4,500 1 Maximum water to cement ratio limits do not apply to lightweight concrete. Geocon Project No. T2754-22-04 - 10 - April 15, 2021 7.2.6 Previous laboratory testing (Geocon, 2002) indicates the site soils have a minimum electrical resistivity of 427 ohm-cm, and a pH of 8.0. As shown in Table 7.2.6 below, the site would be classified as “corrosive” to buried improvements, in accordance with the Caltrans Corrosion Guidelines (Caltrans, 2018). TABLE 7.2.6 CALTRANS CORROSION GUIDELINES Corrosion Exposure Resistivity (ohm-cm) Chloride (ppm) Sulfate (ppm) pH Corrosive <1,100 500 or greater 1,500 or greater 5.5 or less 7.2.7 Geocon does not practice in the field of corrosion engineering. Therefore, further evaluation by a corrosion engineer may be performed if improvements that could be susceptible to corrosion are planned. 7.3 Seismic Design Criteria 7.3.1 The following table summarizes summarizes site-specific design criteria obtained from the 2019 California Building Code (CBC; Based on the 2018 International Building Code [IBC] and ASCE 7-16), Chapter 16 Structural Design, Section 1613 Earthquake Loads. The data was calculated using the online application Seismic Design Maps, provided by OSHPD. The short spectral response uses a period of 0.2 second. We evaluated the Site Class based on the discussion in Section 1613.2.2 of the 2019 CBC and Table 20.3-1 of ASCE 7-16. Although the site is subject to liquefaction resulting in Site Class F, because the period of the planned structures is less than 0.5 seconds, values of Site Class D are applicable. The values presented in Table 7.3.1 below are for the risk-targeted maximum considered earthquake (MCER). Geocon Project No. T2754-22-04 - 11 - April 15, 2021 TABLE 7.3.1 2019 CBC SEISMIC DESIGN PARAMETERS Parameter Value 2016 CBC Reference Site Class D Section 1613.3.2 MCER Ground Motion Spectral Response Acceleration – Class B (short), SS 1.00g Figure 1613.3.1(1) MCER Ground Motion Spectral Response Acceleration – Class B (1 sec), S1 0.36g Figure 1613.3.1(2) Site Coefficient, FA 1.3 Table 1613.3.3(1) Site Coefficient, FV 1.94 Table 1613.3.3(2) Site Class Modified MCER Spectral Response Acceleration (short), SMS 1.20 Section 1613.3.3 (Eqn 16-37) Site Class Modified MCER Spectral Response Acceleration (1 sec), SM1 .704 Section 1613.3.3 (Eqn 16-38) 5% Damped Design Spectral Response Acceleration (short), SDS 0.801 g Section 1613.3.4 (Eqn 16-39) 5% Damped Design Spectral Response Acceleration (1 sec), SD1 0.469 Section 1613.3.4 (Eqn 16-40) Note: *Per Section 11.4.8 of ASCE/SEI 7-16, a ground motion hazard analysis shall be performed for projects for Site Class “E” sites with Ss greater than or equal to 1.0g and for Site Class “D” and “E” sites with S1 greater than 0.2g. Section 11.4.8 also provides exceptions which indicates that the ground motion hazard analysis may be waived provided the exceptions are followed. Using the code based values presented in the table above, in lieu of performing a ground motion hazard analysis, requires the exceptions outlined in ASCE 7-16 Section 11.4.8 be followed. 7.3.2 Table 7.3.2 presents additional seismic design parameters for projects located in Seismic Design Categories of D through F in accordance with ASCE 7-16 for the mapped maximum considered geometric mean (MCEG). TABLE 7.3.2 2019 CBC SITE ACCELERATION PARAMETERS Parameter Value ASCE 7-10 Reference Site Class D Section 1613.3.2 Mapped MCEG Peak Ground Acceleration, PGA 0.44g Figures 2 through 42-7 Site Coefficient, FPGA 1.2 Table 11.8-1 Site Class Modified MCEG Peak Ground Acceleration, PGAM 0.527g Section 11.8.3 (Eqn 11.8-1) Geocon Project No. T2754-22-04 - 12 - April 15, 2021 7.3.3 Conformance to the criteria in Tables 7.3.1 and 7.3.2 for seismic design does not constitute any kind of guarantee or assurance that significant structural damage or ground failure will not occur if a large earthquake occurs. The primary goal of seismic design is to protect life, not to avoid all damage, since such design may be economically prohibitive. 7.4 Temporary Excavations 7.4.1 The recommendations included herein are provided for temporary excavations. It is the responsibility of the contractor to provide a safe excavation during the construction of the proposed project. 7.4.2 Excavations on the order of 5 to 10 feet in vertical height are expected during grading operations and utility installation. The contractor’s competent person should evaluate the necessity for lay back of vertical cut areas. Vertical excavations up to 5 feet may be attempted where loose soils or caving sands are not present, and where not surcharged by existing structures or vehicle/construction equipment loads. 7.4.3 Vertical excavations greater than 5 feet will require sloping measures in order to provide a stable excavation. We expect that sufficient space is available to complete the majority of the required earthwork for this project using sloping measures. If necessary, compound excavation, slot-cutting, and or shoring recommendations will be provided in an addendum. 7.4.4 Where sloped embankments are utilized, the top of the slope should be barricaded to prevent vehicles and storage loads at the top of the slope within a horizontal distance equal to the height of the slope. If the temporary construction embankments are to be maintained during the rainy season, berms are suggested along the tops of the slopes where necessary to prevent runoff water from entering the excavation and eroding the slope faces. The contractor’s personnel should inspect the soil exposed in the cut slopes during excavation so that modifications of the slopes can be made if variations in the soil conditions occur. Excavations should be stabilized within 30 days of initial excavation. 7.5 Grading 7.5.1 Grading should be performed in accordance with the recommendations provided in this report, the Recommended Grading Specifications contained in Appendix C and City of Carlsbad Standards. 7.5.2 Prior to commencing grading, a pre-construction conference should be held at the site with the owner/developer, city inspector, grading contractor, civil engineer, and geotechnical engineer in attendance. Special soil handling requirements can be discussed at that time. Geocon Project No. T2754-22-04 - 13 - April 15, 2021 7.5.3 Site preparation should begin with the removal of previous structures and infrastructure, deleterious material, debris, buried trash, and vegetation. The depth of removal should be such that material exposed in cut areas or soil to be used as fill is relatively free of organic matter. Material generated during stripping and/or site demolition should be exported from the site. 7.5.4 The undocumented fill and the upper portion of the alluvium in structural areas should be removed to expose competent alluvium. Removals below structures should be extended 2 feet below the bottom of footings or pads and extend laterally two feet beyond the footprint. Where the lateral over-excavation is not possible, deepened footings may be required. 7.5.5 Removals in pavement and walkway areas should extend at least 2 feet beneath the pavement or flatwork subgrade elevation. 7.5.6 The actual depth of removal should be evaluated by the engineering geologist during grading operations. Deeper excavations may be required if loose, soft, or porous materials are present at the base of the removals. The bottom of the excavations should be scarified to a depth of at least 1 foot, moisture conditioned as necessary, and properly compacted. 7.5.7 The site should then be brought to final subgrade elevations with fill compacted in layers. In general, soil native to the site is suitable for use as fill if free from vegetation, debris and other deleterious material. If highly expansive soils (EI > 90) are encountered, they should be placed more than 4 feet below planned improvements. Layers of fill should be about 6 to 8 inches in loose thickness and no thicker than will allow for adequate bonding and compaction. Fill, including backfill and scarified ground surfaces, should be compacted to a dry density of at least 90 percent of the laboratory maximum dry density at 0 to 2 percent above optimum moisture content, as determined in accordance with ASTM D 1557. Fill materials placed below optimum moisture content may require additional moisture conditioning prior to placing additional fill. The upper 12 inches of subgrade soil underlying pavement should be compacted to a dry density of at least 95 percent of the laboratory maximum dry density at 0 to 2 percent above optimum moisture content shortly before paving operations. 7.5.8 Import fill soil (if necessary) should consist of granular materials with a “low” expansion potential (EI of less than 50), free of deleterious material and rock fragments larger than 6 inches and should be compacted as recommended herein. Geocon should be notified of the import soil source and should perform laboratory testing of import soil prior to its arrival at the site to determine its suitability as fill material. Geocon Project No. T2754-22-04 - 14 - April 15, 2021 7.5.9 Foundation excavation bottoms must be observed and approved in writing by the Geotechnical Engineer, prior to placing fill, steel, gravel or concrete. 7.6 Earthwork Grading Factors 7.6.1 Estimates of shrinkage factors are based on empirical judgments comparing the material in its existing or natural state as encountered in the exploratory excavations to a compacted state. Variations in natural soil density and in compacted fill density render shrinkage value estimates very approximate. As an example, the contractor can compact the fill to a dry density of 90 percent or higher of the laboratory maximum dry density. Thus, the contractor has an approximately 10 percent range of control over the fill volume. Based on our experience and the densities measured during our investigation, the shrinkage of undocumented fill and alluvium soil is expected to be up to 10 percent when compacted to at least 90 percent of the laboratory maximum dry density. This estimate is for preliminary quantity estimates only. Due to the variations in the actual shrinkage/bulking factors, a balance area should be provided to accommodate variations. 7.7 Foundation and Concrete Slab-On-Grade Recommendations 7.7.1 The foundation recommendations presented herein are for the proposed structures subsequent to the recommended grading assuming that the structures are founded in soils with a low to medium expansion potential. If soils with a high expansion potential are placed within 4 feet of finish grade, then Geocon should be contacted for additional recommendations. The proposed structure can be supported on a shallow foundation system bearing in newly placed compacted fill. 7.7.2 Foundations for the structure should consist of either continuous strip footings and/or isolated spread footings. Continuous footings should be at least 18 inches wide and extend at least 18 inches below lowest adjacent pad grade. Isolated spread footings should have a minimum width of 24 inches and should also extend at least 18 inches below lowest adjacent pad grade. A wall/column footing dimension detail depicting footing embedment is provided on Figure 3. 7.7.3 From a geotechnical engineering standpoint, concrete slabs-on-grade for the structure should be at least 4 inches thick and be reinforced with at least No. 3 steel reinforcing bars placed 24 inches on center in both directions. The concrete slab-on-grade recommendations are based on soil support characteristics only. The project structural engineer should evaluate the structural requirements of the concrete slab for supporting equipment and storage loads. A thicker concrete slab may be required for heavier loading conditions. To reduce the effects of differential settlement on the foundation system, thickened slabs and/or an increase in steel reinforcement can provide a benefit to reduce concrete cracking. Geocon Project No. T2754-22-04 - 15 - April 15, 2021 7.7.4 Steel reinforcement for continuous footings should consist of at least four No. 4 steel reinforcing bars placed horizontally in the footings, two near the top and two near the bottom. Steel reinforcement for the spread footings should be designed by the project structural engineer. 7.7.5 The recommendations presented herein are based on soil characteristics only (EI of 90 or less) and are not intended to replace steel reinforcement required for structural considerations. 7.7.6 Foundations may be designed for an allowable soil bearing pressure of 3,000 pounds per square foot (psf) (dead plus live load). The value presented herein is for dead plus live loads and may be increased by one-third when considering transient loads due to wind or seismic forces. 7.7.7 The maximum expected static settlement for the planned structures supported on conventional foundation systems with the above allowable bearing pressure and deriving support in engineered fill is estimated to be 1 inch and to occur below the heaviest loaded structural element. Differential settlement is estimated to be on the order of ½ inch over a horizontal distance of 40 feet. Once the design and foundation loading configuration proceeds to a more finalized plan, the estimated settlements within this report should be reviewed and revised, if necessary 7.7.8 Once the design and foundation loading configuration proceeds to a more finalized plan, the estimated settlements within this report should be reviewed and revised, if necessary. 7.7.9 Special subgrade presaturation is not deemed necessary prior to placing concrete; however, the exposed foundation subgrade soil should be moisturized to maintain a moist condition as would be expected in any such concrete placement. 7.7.10 Geocon should be consulted to provide additional design parameters as required by the structural engineer. 7.8 Concrete Flatwork 7.8.1 Exterior concrete flatwork not subject to vehicular traffic should be constructed in accordance with the recommendations herein. Slab panels should be a minimum of 4 inches thick and, when in excess of 8 feet square, should be reinforced with No. 3 reinforcing bars spaced 24 inches on center in each direction to reduce the potential for wide cracking. In addition, concrete flatwork should be provided with crack control joints to reduce and/or control shrinkage cracking. Crack control spacing should be determined by the project structural engineer based upon the slab thickness and intended usage. Criteria of the Geocon Project No. T2754-22-04 - 16 - April 15, 2021 American Concrete Institute (ACI) should be taken into consideration when establishing crack control spacing. Subgrade soil for exterior slabs not subjected to vehicle loads should be compacted in accordance with criteria presented in the grading section prior to concrete placement. Subgrade soil should be properly compacted and the moisture content of subgrade soil should be checked prior to placing concrete. 7.8.2 Even with the incorporation of the recommendations within this report, the exterior concrete flatwork has a likelihood of experiencing some movement due to swelling or settlement; therefore, the steel reinforcement should overlap continuously in flatwork to reduce the potential for vertical offsets within flatwork. Additionally, flatwork should be structurally connected to the curbs, where possible, to reduce the potential for offsets between the curbs and the flatwork. 7.8.3 Where exterior flatwork abuts structures at entrant or exit points, the exterior slab should be dowelled into the structure’s foundation stemwall. This recommendation is intended to reduce the potential for differential elevations that could result from differential settlement or minor heave of the flatwork. Dowelling details should be designed by the project structural engineer. 7.8.4 The recommendations presented herein are intended to reduce the potential for cracking as a result of differential movement. However, even with the incorporation of the recommendations presented herein, concrete will still crack. The occurrence of concrete shrinkage cracks is independent of the soil supporting characteristics. Their occurrence may be reduced and/or controlled by limiting the slump of the concrete, the use of crack control joints and proper concrete placement and curing. Crack control joints should be spaced at intervals no greater than 12 feet. Literature provided by the Portland Concrete Association (PCA) and American Concrete Institute (ACI) present recommendations for proper concrete mix, construction, and curing practices, and should be incorporated into project construction. 7.9 Conventional Retaining Walls 7.9.1 The recommendations presented herein are generally applicable to the design of rigid concrete or masonry retaining walls having a maximum height of 10 feet. In the event that walls higher than 10 feet or other types of walls are planned, Geocon should be consulted for additional recommendations. 7.9.2 Retaining walls not restrained at the top and having a level backfill surface should be designed for an active soil pressure equivalent to the pressure exerted by a fluid density of 35 pounds per cubic foot (pcf). Where the backfill will be inclined at no steeper than 2:1 (horizontal to vertical), an active soil pressure of 55 pcf is recommended. These soil pressures assume that the backfill materials within an area bounded by the wall and a Geocon Project No. T2754-22-04 - 17 - April 15, 2021 1:1 plane extending upward from the base of the wall possess an EI of 50 or less. For walls where backfill materials do not conform to the criteria herein, Geocon should be consulted for additional recommendations. 7.9.3 Unrestrained walls are those that are allowed to rotate more than 0.001H (where H equals the height of the retaining portion of the wall in feet) at the top of the wall. Where walls are restrained from movement at the top, walls with a level backfill surface should be designed for a soil pressure equivalent to the pressure exerted by a fluid density of 60 pcf. 7.9.4 The structural engineer should determine the seismic design category for the project in accordance with Section 1613 of the CBC. If the project possesses a seismic design category of D, E, or F, proposed retaining walls in excess of 6 feet in height should be designed with seismic lateral pressure (Section 1803.5.12 of the 2019 CBC). 7.9.5 A seismic load of 10 pcf should be used for design of walls that support more than 6 feet of backfill in accordance with Section 1803.5.12 of the 2019 CBC. The seismic load is applied as an equivalent fluid pressure along the height of the wall and the calculated loads result in a maximum load exerted at the base of the wall and zero at the top of the wall. This seismic load should be applied in addition to the active earth pressure. The earth pressure is based on half of two-thirds of PGAM calculated from ASCE 7-10 Section 11.8.3. 7.9.6 Unrestrained walls will move laterally when backfilled and loading is applied. The amount of lateral deflection is dependent on the wall height, the type of soil used for backfill, and loads acting on the wall. The retaining walls and improvements above the retaining walls should be designed to incorporate an appropriate amount of lateral deflection as determined by the structural engineer. 7.9.7 Retaining walls should be provided with a drainage system adequate to prevent the buildup of hydrostatic forces and waterproofed as required by the project architect. The soil immediately adjacent to the backfilled retaining wall should be composed of free draining material completely wrapped in Mirafi 140N (or equivalent) filter fabric for a lateral distance of 1 foot for the bottom two-thirds of the height of the retaining wall. The upper one-third should be backfilled with less permeable compacted fill to reduce water infiltration. Alternatively, a drainage panel, such as a Miradrain 6000 or equivalent, can be placed along the back of the wall. A typical drain detail for each option is shown on Figure 4. The use of drainage openings through the base of the wall (weep holes) is not recommended where the seepage could be a nuisance or otherwise adversely affect the property adjacent to the base of the wall. The recommendations herein assume a properly compacted backfill (EI of 50 or less) with no hydrostatic forces or imposed surcharge load. If conditions different than those described are expected or if specific drainage details are desired, Geocon should be contacted for additional recommendations. Geocon Project No. T2754-22-04 - 18 - April 15, 2021 7.9.8 Wall foundations should be designed in accordance with the above foundation recommendations. 7.10 Lateral Loading 7.10.1 To resist lateral loads, a passive pressure exerted by an equivalent fluid density of 300 pounds per cubic foot (pcf) should be used for the design of footings or shear keys. The allowable passive pressure assumes a horizontal surface extending at least 5 feet, or three times the surface generating the passive pressure, whichever is greater. The upper 12 inches of material in areas not protected by floor slabs or pavement should not be included in design for passive resistance. 7.10.2 If friction is to be used to resist lateral loads, an allowable coefficient of friction between soil and concrete of 0.35 should be used for design. The friction coefficient may be reduced depending on the vapor barrier or waterproofing material used for construction in accordance with the manufacturer’s recommendations. 7.10.3 The passive and frictional resistant loads can be combined for design purposes. The lateral passive pressures may be increased by one-third when considering transient loads due to wind or seismic forces. 7.11 Preliminary Pavement Recommendations 7.11.1 In the event flexible pavements are constructed, we calculated flexible pavement sections in general conformance with the Caltrans Method of Flexible Pavement Design (Highway Design Manual, Section 608.4) and San Diego County specifications using a range of Traffic Indices. The project civil engineer and owner should evaluate the final Traffic Index for the pavements and review the pavement designations to determine appropriate locations for pavement thickness. Based on the laboratory testing of the onsite soils, we have used a preliminary R-value of 7 for the subgrade soils for the purposes of this analysis. The final pavement sections should be based on the R-value of the subgrade soil encountered at final subgrade elevation. Table 7.11.1 presents the preliminary flexible pavement sections. TABLE 7.11.1 PRELIMINARY FLEXIBLE PAVEMENT SECTION Location Assumed Traffic Index Subgrade R-Value Asphalt Concrete (inches) Class 2 Aggregate Base (inches) Driveways for automobiles and light-duty vehicles 5.5 7 3.0 11.5 Medium truck traffic areas 6.0 3.5 12.5 Driveways for heavy truck and fire truck traffic 7.0 4.0 15.0 Geocon Project No. T2754-22-04 - 19 - April 15, 2021 7.11.2 Prior to placing base materials, the upper 12 inches of the subgrade soil should be scarified, moisture conditioned as necessary, and recompacted to a dry density of at least 95 percent of the laboratory maximum dry density at 0 to 2 percent above optimum moisture content as determined by ASTM D 1557. Similarly, the base material should be compacted to a dry density of at least 95 percent of the laboratory maximum dry density at 0 to 2 percent above optimum moisture content. Asphalt concrete should be compacted to a density of at least 95 percent of the laboratory Hveem density in accordance with ASTM D 2726. 7.11.3 Base materials should conform to Section 26-1.028 of the Standard Specifications for The State of California Department of Transportation (Caltrans). The asphalt concrete should conform to Section 203-6 of the Standard Specifications for Public Works Construction (Greenbook). 7.11.4 A rigid Portland cement concrete (PCC) pavement section should be placed in heavy truck areas, driveway aprons, and cross gutters. We calculated the rigid pavement section in general conformance with the procedure recommended by the American Concrete Institute report ACI 330R Guide for Design and Construction of Concrete Parking Lots using the parameters presented in Table 7.11.4. TABLE 7.11.4 RIGID PAVEMENT DESIGN PARAMETERS Design Parameter Design Value Modulus of subgrade reaction, k 200 pci Modulus of rupture for concrete, MR 500 psi Traffic Category, TC C and D Average daily truck traffic, ADTT 100 and 700 7.11.5 Based on the criteria presented herein, the PCC pavement sections should have a minimum thickness as presented in Table 7.11.5. TABLE 7.11.5 RIGID PAVEMENT RECOMMENDATIONS Location Portland Cement Concrete (inches) Cart Paths (no heavy truck traffic) 4.0 Automobile Parking Stalls (TC=C) 6.5 Heavy Truck and Fire Lane Areas (TC=D) 7.5 Geocon Project No. T2754-22-04 - 20 - April 15, 2021 7.11.6 The PCC pavement should be placed over subgrade soil that is compacted to a dry density of at least 95 percent of the laboratory maximum dry density at 0 to 2 percent above optimum moisture content. This pavement section is based on a minimum concrete compressive strength of approximately 3,500 psi (pounds per square inch). 7.11.7 A thickened edge or integral curb should be constructed on the outside of concrete slabs subjected to wheel loads. The thickened edge should be 1.2 times the slab thickness or a minimum thickness of 2 inches, whichever results in a thicker edge, and taper back to the recommended slab thickness 4 feet behind the face of the slab (e.g., 6-inch and 7.5-inch-thick slabs would have an 8- and 9.5-inch-thick edge, respectively). Reinforcing steel will not be necessary within the concrete for geotechnical purposes with the possible exception of dowels at construction joints as discussed herein. 7.11.8 In order to control the location and spread of concrete shrinkage cracks, crack-control joints (weakened plane joints) should be included in the design of the concrete pavement slab in accordance with the referenced ACI report. 7.11.9 The performance of pavements is highly dependent on providing positive surface drainage away from the edge of the pavement. Ponding of water on or adjacent to the pavement surfaces will likely result in pavement distress and subgrade failure. Drainage from landscaped areas should be directed to controlled drainage structures. Landscape areas adjacent to the edge of asphalt pavements are not recommended due to the potential for surface or irrigation water to infiltrate the underlying permeable aggregate base and cause distress. Where such a condition cannot be avoided, consideration should be given to incorporating measures that will significantly reduce the potential for subsurface water migration into the aggregate base. If planter islands are planned, the perimeter curb should extend at least 6 inches below the level of the base materials. 7.12 Site Drainage and Moisture Protection 7.12.1 Adequate site drainage is critical to reduce the potential for differential soil movement, erosion and subsurface seepage. Under no circumstances should water be allowed to pond adjacent to footings. The site should be graded and maintained such that surface drainage is directed away from structures in accordance with 2019 CBC 1804.4 or other applicable standards. In addition, surface drainage should be directed away from the top of slopes into swales or other controlled drainage devices. Roof and pavement drainage should be directed into conduits that carry runoff away from the proposed structure. Geocon Project No. T2754-22-04 - 21 - April 15, 2021 7.12.2 In the case of walls retaining landscaping areas, a water-proofing system should be used on the wall and joints, and a Miradrain drainage panel (or similar) should be placed over the waterproofing. The project architect or civil engineer should provide detailed specifications on the plans for all waterproofing and drainage. 7.12.3 Landscape planters that saturate the subsurface should not be used within 20 feet of the proposed structure or other settlement sensitive on grade improvements. Localized surface settlement should be anticipated in areas where water is allowed to infiltrate into the subsurface. 7.12.4 Underground utilities should be leak free. Utility and irrigation lines should be checked periodically for leaks, and detected leaks should be repaired promptly. Detrimental soil movement could occur if water is allowed to infiltrate the soil for prolonged periods of time. 7.12.5 Landscaping planters adjacent to paved areas are not recommended due to the potential for surface or irrigation water to infiltrate the pavement's subgrade and base course. Area drains to collect excess irrigation water and transmit it to drainage structures or impervious above-grade planter boxes can be used. In addition, where landscaping is planned adjacent to the pavement, construction of a cutoff wall along the edge of the pavement that extends at least 6 inches below the bottom of the base material should be considered. 7.12.6 If not properly constructed, there is a potential for distress to improvements and properties located hydrologically down gradient or adjacent to infiltration areas. Factors such as the amount of water to be detained, its residence time, and soil permeability have an important effect on seepage transmission and the potential adverse impacts that may occur if the storm water management features are not properly designed and constructed. We have not performed a hydrogeology study at the site. Down-gradient and adjacent structures may be subjected to seeps, movement of foundations and slabs, or other impacts as a result of water infiltration. 7.13 Grading and Foundation Plan Review 7.13.1 Geocon should review the project grading and foundation plans prior to final design submittal to verify that the plans have been prepared in substantial conformance with the recommendations of this report and to provide additional analyses or recommendations, if necessary. Geocon Project No. T2754-22-04 April 15, 2021 LIMITATIONS AND UNIFORMITY OF CONDITIONS 1. The firm that performed the geotechnical investigation for the project should be retained to provide testing and observation services during construction to provide continuity of geotechnical interpretation and to check that the recommendations presented for geotechnical aspects of site development are incorporated during site grading, construction of improvements, and excavation of foundations. If another geotechnical firm is selected to perform the testing and observation services during construction operations, that firm should prepare a letter indicating their intent to assume the responsibilities of project geotechnical engineer of record. A copy of the letter should be provided to the regulatory agency for their records. In addition, that firm should provide revised recommendations concerning the geotechnical aspects of the proposed development, or a written acknowledgement of their concurrence with the recommendations presented in our report. They should also perform additional analyses deemed necessary to assume the role of Geotechnical Engineer of Record. 2. The recommendations of this report pertain only to the site investigated and are based upon the assumption that the soil conditions do not deviate from those disclosed in the investigation. If any variations or undesirable conditions are encountered during construction, or if the proposed construction will differ from that anticipated herein, Geocon should be notified so that supplemental recommendations can be given. The evaluation or identification of the potential presence of hazardous or corrosive materials was not part of the scope of services provided by Geocon. 3. This report is issued with the understanding that it is the responsibility of the owner or their representative to ensure that the information and recommendations contained herein are brought to the attention of the architect and engineer for the project and incorporated into the plans, and the necessary steps are taken to see that the contractor and subcontractors carry out such recommendations in the field. 4. The findings of this report are valid as of the date of this report. However, changes in the conditions of a property can occur with the passage of time, whether they be due to natural processes or the works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and should not be relied upon after a period of three years. Geocon Project No. T2754-22-04 - 1 - April 15, 2021 LIST OF REFERENCES 1. American Concrete Institute, 2014, Building Code Requirements for Structural Concrete and Commentary on Building Code Requirements for Structural Concrete, prepared by the American Concrete Institute Committee 318, dated September. 2. American Concrete Institute, 2008, 330R Guide for the Design and Construction of Concrete Parking Lots, American Concrete Institute Committee 330, dated June. 3. American Concrete Institute, 2006, 302.2R Guide for Guide for Concrete Slabs that Receive Moisture-Sensitive Flooring Materials, American Concrete Institute Committee 302. 4. Anderson, J. G., T. K. Rockwell, and D. C. Agnew, 1989, Past and Possible Future Earthquakes of Significance to the San Diego Region: Earthquake Spectra, v.5, no. 2, p.299-333. 5. ASCE 7-16, 2018, Minimum Design Loads for Buildings and Other Structures, Second Printing, April 6. 6. Boore, D. M., and G. M Atkinson 2008, Ground-Motion Prediction for the Average Horizontal Component of PGA, PGV, and 5%-Damped PSA at Spectral Periods Between 0.01 and 10.0 S, Earthquake Spectra, Volume 24, Issue 1, pp. 99-138, February. 7. California Building Standards Commission, 2019, California Building Code (CBC), California Code of Regulations Title 24, Part 2. 8. California Department of Conservation, 1996, Division of Mines and Geology, Probabilistic Seismic Hazard Assessment for the State of California, Open File Report 96-08. 9. California Department of Transportation (Caltrans), 2018, Division of Engineering Services, Materials Engineering and Testing Services, Corrosion Guidelines, Version 3.0, dated March. 10. Caltrans, 2017, Highway Design Manual, Sixth Edition. 11. Caltrans, 2015, Standard Specifications. 12. California Geological Survey, 2002, Seismic Shaking Hazards in California, Based on the USGS/CGS Probabilistic Seismic Hazards Assessment (PSHA) Model, (revised April 2003). 10% probability of being exceeded in 50 years. http://redirect.conservation.ca.gov/cgs/rghm/pshamap/pshamain.html 13. California Geologic Survey, 2008, Special Publication 117A, Guidelines for Evaluating and Mitigating Seismic Hazards in California, Revised and Re-adopted September 11. 14. Campbell, K. W., and Y. Bozorgnia, 2008, NGA Ground Motion Model for the Geometric Mean Horizontal Component of PGA, PGV, PGD and 5% Damped Linear Elastic Response Spectra for Periods Ranging from 0.01 to 10 s, Preprint of version submitted for publication in the NGA Special Volume of Earthquake Spectra, Volume 24, Issue 1, pages 139-171, dated February. LIST OF REFERENCES (Continued) Geocon Project No. T2754-22-04 April 15, 2021 15. Carlsbad General Plan, available at www.carlsbadca.gov/services/depts/planning/update/ documents.asp, accessed January 30, 2016. 16. Carlsbad, Engineering Standards, Volume 3, Standard Drawings and Specifications, dated 2004. 17. Chiou, Brian S. J., and Robert R. Youngs, 2008, A NGA Model for the Average Horizontal Component of Peak Ground Motion and Response Spectra, preprint for article to be published in NGA Special Edition for Earthquake Spectra. 18. Geocon Inc, 2002, Geotechnical Investigation, La Costa Trunk Sewer, La Costa California, Project No. 06796-22-01, revised July 17 19. Google Inc., Google Maps online mapping software, accessed January 24, 2017. 20. Google Inc., Google Earth Pro, Version 7.1.2.2041, accessed January 24, 2017. 21. Harden, D.R., California Geology, Prentice-Hall, Inc., 479 pp., 1998. 22. Jennings, C. W., 2010, California Division of Mines and Geology, Fault Activity Map of California and Adjacent Areas, California Geologic Data Map Series Map No. 6. 23. Legg, M. R., J. C. Borrero, and C. E. Synolakis, Evaluation of Tsunami Risk to Southern California Coastal Cities, 2002 NEHRP Professional Fellowship Report, dated January 2003. 24. Morton, D.M., Preliminary Digital Geologic Map of the Santa Ana 30’x60’ Quadrangle, Southern California. 25. OSPD, 2018, Seismic Design Maps, https://seismicmaps.org Accessed November 18, 2018. 26. Public Works Standards, Inc., 2018, Standard Specifications for Public Works Construction “Greenbook,” Published by BNi Building News. 27. Tan, S.S., and Kennedy, M. P. 1996, Geologic Map of the Encinitas and Rancho Santa Fe 7.5’ Quadrangles, San Diego County, California, in DMG OFR 96-02. 28. Unpublished Geotechnical Reports and Information, Geocon West, Inc. SOURCE: Google Earth, 2021 VICINITY MAP CHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA APRIL 2021 PROJECT NO. T2754-22-04 FIG. 1LCW PROJECT BOUNDARY SCALE: 1” = 3000’ 0’ 3000’ 6000’ La Costa Avenue GEOCON W E S T , I N C. GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101 , MURRIETA, CALIFORNIA 92562 PHONE 951 -304-2300 FAX 951-304-2392 I I BORING LOCATION MAP APRIL 2021 PROJECT NO. T754-22-04 FIG. 2LCW CHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROADCARLSBAD, CALIFORNIA SOURCE: Google Earth 2021 SCALE 1” = 800’ 0                          800                         1600 GEOCON LEGEND Locations are approximate B-6 ……. BORING LOCATION (GEOCON, THIS REPORT) B-8 ……. BORING LOCATION (GEOCON, 2002) .….. PROJECT LIMITS B-3 B-1 B-2 B-4 B-5 B-6 B-5 B-4 B-6 B-8 B-7 B-1 B-3 B-2 N GEOCON W E S T , I N C. GEOTECHNICAL ENVIRONMENTAL MATERIALS 41571 CORNING PLACE, SUITE 101 , MURRIETA, CA 92562 PHONE 951-304-2300 FAX 951-304-2392 I -Ill ' ' t I NO SCALENOTE: SEE REPORT FOR FOUNDATION WIDTH AND DEPTH RECOMMENDATION APRIL 2021 PROJECT NO. T2745-22-04 FIG. 3 WALL / COLUMN FOOTING DETAIL PDT WALL FOOTING CONCRETE SLAB FINISHED PAD GRADE FOUNDATIONEMBEDMENTFOUNDATIONEMBEDMENTFOUNDATION WIDTH CLEAN SAND VAPOR BARRIER COLUMN FOOTING CLEAN SAND VAPOR BARRIER FOUNDATION WIDTH FOUNDATIONEMBEDMENTCHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA <l <l <l <! <l jl <1 <l <! <! <!· ~ ,)i::_/A/~ LI. v <!<l <l ,; <l <J GEOCON W E S T , I N C. GEOTECHNICAL ENVIRONMENTAL MATERIALS 41571 CORNING PLACE, SUITE 101, MURRIETA, CA 92562-7065 PHONE 951-304-2300 FAX 951-304-2392 1/ Y, 1/ <! <l <l <! <! " <l "<! <l <l A <J <l <! <! <! 1l <! '1 <l d %'-..':/);:/A ~ ~ \ <l<! <! <l <l <! I ;:,,>::f>:: <l I .. .... ..... ................... . ............ .. ... APRIL 2021 PROJECT NO. T2745-22-04 FIG. 4PDT TYPICAL RETAINING WALL DRAIN DETAIL NOTES: DRAIN SHOULD BE UNFORMLY SLOPED TO GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPIMG CONCRETE BROW DITCH RECOMMENDED FOR SLOPE HEIGHTS  GREATER THAN 6 FEET 2/3 H GROUND SURFACE CONCRETE BROWDITCH PROPOSED RETAINING WALL GROUND SURFACE FOOTING TEMPORARY BACKCUT PER OSHA MIRAFI 140N FILTER FABRIC (OR EQUIVALENT) OPEN‐GRADED ¾” MAX. AGGREGATE 4” DIA. PERFORATED SCHEDULE 40 PVC PIPE EXTENDED TO  APPROVED OUTLET 1” 12” . 2/3 H GROUND SURFACE CONCRETE BROWDITCH PROPOSED RETAINING WALL PROPOSED  GRADE FOOTING MIRAFI 140N FILTER FABRIC (OR EQUIVALENT) OPEN‐GRADED ¾” MAX. AGGREGATE (1 CU. FT./FT.) 4” DIA. PERFORATED SCHEDULE 40 PVC PIPE EXTENDED TO  APPROVED OUTLET 12” .... .... .. WATER PROOFING PER ARCHITECT PROPERLY COMPACTED BACKFILL WATER PROOFING PER ARCHITECT DRAINAGE PANEL (MIRADRAIN 6000 OR EQUIVALENT) NO SCALE CHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOCON W E S T , I N C. GEOTECHNICAL ENVIRONMENTAL MATERIALS 41571 CORNING PLACE, SUITE 101, MURRIETA, CA 92562-7065 PHONE 951-304-2300 FAX 951-304-2392 I I APPENDIX A Geocon Project No. T2754-22-04 -A- April 15, 2021 APPENDIX A FIELD INVESTIGATION Field work for our investigation included a site reconnaissance, subsurface exploration, and soil sampling. The Boring Location Map, Figure 2 presents the locations of the exploratory borings. Boring logs and an explanation of the geologic units encountered are presented in figures following the text in this appendix. We located the borings in the field using existing reference points. Therefore, actual boring locations may deviate slightly. We performed a field investigation on March 15, 2021 which consisted of drilling 2 exploratory borings to a maximum depth of approximately 19.5 feet below existing grade with a CME 75 drill rig equipped with 8-inch-diameter hollow-stem auger and 4 hand auger borings to depths of 5 feet below existing grade. We collected bulk and relatively undisturbed samples from the borings by driving a 3-inch O. D., California Modified Sampler into the “undisturbed” soil mass with blows from a 140-pound hammer falling 30 inches on an auto hammer. The California Modified Sampler was equipped with 1-inch high by 23/8-inch inside diameter brass sampler rings to facilitate removal and testing. Relatively undisturbed samples and bulk samples of disturbed soils were transported to our laboratory for testing. The type of sample is noted on the exploratory boring logs. The samplers were driven 18 inches into the bottom of the excavations. Blow counts are recorded for every 6 inches the sampler is driven. The penetration resistances shown on the boring logs are shown in terms of blows per foot. The values indicated on the boring logs are the sum of the last 12 inches of the sampler if driven 18 inches. If the sampler was not driven for 18 inches, an approximate value is calculated in term of blows per foot or the final 6-inch interval is reported. These values are not to be taken as N-values; adjustments have not been applied. We estimated elevations shown on the boring logs from Google Earth. We visually examined the soil conditions encountered within the borings, classified, and logged in general accordance with the Unified Soil Classification System (USCS). Logs of the borings are presented on Figures A-1 through A-6. Logs of borings from a previous investigation (Geocon, 2002) are presented on Figures A-7 through A-14. The logs depict the general soil and geologic conditions encountered and the depth at which we obtained the samples. 96.0 101.7 99.0 99.7 99.7 27 21 15 19 19 14 CL CL SC B-1@0-5' B-1@2.5' B-1@5.0' B-1@7.5' B-1@10.0'' B-1@15.0' B-1@18.0' UNDOCUMENTED FILL (afu) sandy CLAY, stiff, moist, dark brown; fine sand; micaceous; grass on surface YOUNG ALLUVIAL DEPOSITS (Qya) Sandy CLAY, moist, stiff, dark brown; fine sand; micaceous -Becomes wet -Becomes saturated -Becomes fine to coarse sand, light brown with some gray Clayey SAND, medium dense, saturated, light brown with reddish yellow staining; fine to coarse sand Total depth 19.5 feet Groundwater stabilized at 7.2 feet Penetration resistance for 140 lb. hammer falling 30" by auto hammer Backfilled with curttings on 3/15/2021 20.8 25.1 24.3 21.1 25.8PENETRATION ... DRIVE SAMPLE (UNDISTURBED) HOLLOW STEM AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-1, Log of Boring B-1, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 6 8 10 12 14 16 18 SAMPLE NO.RESISTANCE21 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE BORING B-1 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,--// ~ -~ 1// ~ ,--~ ½ ~ -~ ,--~ ~ ½ ~ - ,--½ ~ -"¥- ,--½ ~ - ,--½ ~ -½ ,-- ~ -½ ,-- ~ -½ ,--~ ~ - ?/-/ ,---·/ (// ~ -<-// ---- I ---------------------------------- I] liiiiJ - - - - - - - - - - - - - - - ----------- - 98.4 90.6 87.9 86.5 87.8 20 17 7 14 9 13 CL CL SC CL B-2@0-5.0' B-2@2.5' B-2@5.0' B-2@7.5' B-2@10.0' B-2@15.0' B-2@18.0' UNDOCUMENTED FILL (afu) sandy CLAY, stiff, moist, dark brown; fine sand; micaceous; grass on surface YOUNG ALLUVIAL DEPOSITS (Qya) Sandy CLAY, moist, stiff, dark brown; fine sand; micaceous Clayey SAND, medium dense, moist, reddish brown; fine to coarse sand; micaceous Sandy CLAY, stiff, wet, dark brown; fine sand; some medium sand; micaceous -Becomes saturated, black -Becomes gray with red staining; fine sand Total depth 19.5 feet Groundwater stabilized at 8.0 feet Penetration resistance for 140 lb. hammer falling 30" by auto hammer Backfilled with curttings on 3/15/2021 21.1 35.2 36.1 28.2 37.2PENETRATION ... DRIVE SAMPLE (UNDISTURBED) HOLLOW STEM AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-2, Log of Boring B-2, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 6 8 10 12 14 16 18 SAMPLE NO.RESISTANCE12 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE BORING B-2 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,--// ~ -~ (-Ii) ~ ,--------~ ;-_/;; ~ -~ ;// ,--~ ~ ✓/f ~ -"'/ , 1// ,-- ~ -½ ,--"¥-½ ~ - ,--½ ~ - ,--½ ~ - ,--½ ~ -½ ,-- ~ -~ ,-- ~ - I h ,---- \ I L _______________________________ J - I] liiiiJ - - - - - - - - - - - - - - - r-------- SM SM B-3@0-5.0'UNDOCUMENTED FILL (afu) Silty SAND, damp, light brown, moist; fine to medium sand; some coarse sand; micaceous YOUNG ALLUVIAL DEPOSITS (Qya) Silty SAND, moist, medium dense, brown; fine to medium sand; micaceous Total depth 5.0 feet Groundwater not encountered Backfilled with cuttings on 3/15/2021 PENETRATION... DRIVE SAMPLE (UNDISTURBED) HAND AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-3, Log of Hand Auger B-3, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 SAMPLE NO.RESISTANCE122 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE HAND AUGER B-3 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,-- ~ -~ ~ ,--~ ~ -~ ~ ,-- ~ ~ .1 1_-1_ :-1. 7-l l~ ·1 :-l rl- .-1-l :i--! ·1 I] liiiiJ - - - - SM SM B-4@0-5.0'UNDOCUMENTED FILL (afu) Silty SAND, damp, light brown, moist; fine to medium sand; some coarse sand; micaceous YOUNG ALLUVIAL DEPOSITS (Qya) Silty SAND, moist, medium dense, brown; fine to medium sand; micaceous Total depth 5.0 feet Groundwater not encountered Backfilled with cuttings on 3/15/2021 PENETRATION... DRIVE SAMPLE (UNDISTURBED) HAND AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-4, Log of Hand Auger B-4, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 SAMPLE NO.RESISTANCE135 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE HAND AUGER B-4 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,-- ~ -~ ~ ,--~ ~ -~ ~ ,-- ~ ~ .1 1_-1_ :-1. 7-l l~ ·1 :-l rl- .-1-l :i--! ·1 I] liiiiJ - - - - SM SM B-5@0-5.0'UNDOCUMENTED FILL (afu) Silty SAND, damp, light brown, moist; fine to medium sand; some coarse sand; micaceous YOUNG ALLUVIAL DEPOSITS (Qya) Silty SAND, moist, medium dense, brown; fine to medium sand; micaceous Total depth 5.0 feet Groundwater not encountered Backfilled with cuttings on 3/15/2021 PENETRATION... DRIVE SAMPLE (UNDISTURBED) HAND AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-5, Log of Hand Auger B-5, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 SAMPLE NO.RESISTANCE96 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE HAND AUGER B-5 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,-- ~ -~ ~ ,--~ ~ -~ ~ ,-- ~ ~ .-1-~l :-1. 7-l l~ ·1 :-l rl- .-1-l "J-~ -l I] liiiiJ I - - - SM SM B-6@0-5.0'UNDOCUMENTED FILL (afu) Silty SAND, damp, light brown, moist; fine to medium sand; some coarse sand; micaceous YOUNG ALLUVIAL DEPOSITS (Qya) Silty SAND, moist, medium dense, brown; fine to medium sand; micaceous Total depth 5.0 feet Groundwater not encountered Backfilled with cuttings on 3/15/2021 PENETRATION... DRIVE SAMPLE (UNDISTURBED) HAND AUGERLITHOLOGYGROUNDWATERSOIL CLASS (USCS) SAMPLE SYMBOLS DATE COMPLETED (P.C.F.)GEOCON Figure A-6, Log of Hand Auger B-6, Page 1 of 1 ... DISTURBED OR BAG SAMPLE 0 2 4 SAMPLE NO.RESISTANCE66 EQUIPMENT ELEV. (MSL.) ... CHUNK SAMPLE HAND AUGER B-6 DRY DENSITYDEPTH IN FEET ... WATER TABLE OR SEEPAGE 3/15/21 P. THERIAULTBY: T2754-22-04 BORING LOGS.GPJ(BLOWS/FT.)... SAMPLING UNSUCCESSFUL CONTENT (%)... STANDARD PENETRATION TEST MATERIAL DESCRIPTION MOISTUREBULKDR/SPTNOTE: PROJECT NO. THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. T2754-22-04 ,-- ~ -~ ~ ,--~ ~ -~ ~ ,-- ~ ~ .-1-~l :-1. 7-l l~ ·1 :-l rl- .-1-l "J-~ -l I] liiiiJ I - - - FIGURE A-7 PROJECT NO. 06796-22-01 a:: BORING B 1 >-UJ ZUJ"' >-,..., g I-<I: Ou• I-" wX DEPTH _J 3 SOIL Hzl-H. 0::'-' IN SAMPLE 0 □ CLASS ..... <I: LL. (/)LL. =>1-NO. :i:: z ELEV. (MSL.) 12 DATE COMPLETED 4/1/02 <I: I-' z. 1-:z FEET I-::::> (USCS) 0:: CJ) CJ) UJu oow H 0 l:uH8 □. H>-_J a:: EQUIPMENT m A-300 zOO _J >-a.. Oz (.!) W U.110 a:::'-' I:o Q.. 0:: V 0 u MATERIAL DESCRIPTION -0 ~ --SM ALLUVIUM .... Loose, moist to wet, dark brown, Silty, fine to coarse -2 -SAND with clay .... Bl-1 ~-~ ,--~✓-} ---------------------------------------4 -SC -Becomes Clayey SAND ,_ ... -</,1 --------------------------------------Bl-2 ~~ v/ 5 102.3 27.2 / ,I -Becomes soft, wet, grayish brown, CLAY ... 6 -/; - /',/ ... -/1/ -/V /1/ ,-8 -/V /; -/V /; CL /V /; ,--/V /v - / / /v ... 10 -// /V -B1 -3 / / /v -Becomes stiff, gray, Silty CLAY 11 88.0 33.4 --// /',I -// /v // /; -12 -~ //v - //i; --//v -~ //v -14 -//11 -//V I~ //'i,, --/'/v -Becomes very soft, saturated, greenish gray, Silty -Bl-4 //v 2 -16 -~ //v CLAY -/,I BORING TERMINATED AT 16.5 FEET No groundwater encountered Figure A-1, Log of Boring B 1 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDA.RD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) I!§ .•. DISTURBED OR BAG SAMPLE liiiJ ... CHUNK SAMPLE J ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHO\JN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. FIGURE A-8 PROJECT NO. 06796-22-01 a:: BORING B 2 >-UJ Zw'"' >-"' (!) I-0 <C Ou• t:;r-w~ OEPTH ...J :I SOIL Hzl-Cl) • a::"' IN SAMPLE 0 0 CLASS 1-<CIJ.. zu.. :::>1-NO. ::x: z ELEV. (MSL.) 11 DATE COMPLETED 4/1/02 <C1-' w· 1-z FEET I-::) (USCS) o:: en U> □~ U>w H 0 1-H::I ~!z ...J a:: WcnO >-a.. (.!) EQUIPMENT ffi A-300 Zw-' ~ a::!9 O::::v I:o 0 u MATERIAL DESCRIPTION ... 0 ·~ ... -SM ALLUVIUM ... / vv ,; Loose, wet, brown, Silty, fine 10 medium SAND with r ... 2 -i~ ~~ I " __ clay ________________________________ ,' ... 8 2-1 ,; ... --Becomes sofl, dark brown, Silty CLAY ... ~ i/!/ ; :t: ... 4 -vv -~ i/!/ ,I=- ... -vv ,I vv ,I -Becomes firm, saturated, dark gray brown, fine to ,-. 82-2 ~~ ,I CL 8 102.5 21.7 ... 6 -~ / coarse Sandy CLAY -,I ... -/ // / ,-. // /,1 -8 -/i/ /'/ .... /!/ /'/ /V /'/ --~~ /',1 .... /',1 -10 // --------------------------------------82-3 l l 4 --11 ., Becomes loose, Silly, fine 10 coarse SAND with clay - -12 -: 1 t 1· -SM --J ·l .... -14 -ti., -. I ~-1· ---82-4 r .11.-,. 7 ... 16 -I i ·1 ... BORING TERMINATED AT 16.5 FEET Groundwater encountered at 4 feet Figure A-2, Log of Boring B 2 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) l;l§ ... DISTURBED OR BAG SAMPLE liiJ . . . CHUNK SAMPLE ]I'. ... YATER TABLE OR SEEPAGE .. NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. FIGURE A-9 PROJECT NO 06796-22-01 0:: BORING B 3 >-w zw,-.. >-" (.!) I- 0 (C Ou• l:ii-; w~ DEPTH ...J 3 SOIL ~zt;: o::"' IN SAMPLE 0 0 CLASS <C (C" (f),LL. ::::> I-NO. :c z ELEV. (MSL.) 22 DATE COMPLETED 4/1/02 0:: I-(/) ffi . 1-z FEET I-::::> (USCS) I-(/) :::r 0 1~ (/)u.l H 0 wHo ~~ ...J 0:: EQUIPMENT m A-300 Z(f)..J >-·o.. (.!) wWco a::'-' :Co 0.. O::v-0 u MATERIAL DESCRIPTION -0 0 --ALLUV1UM -Loose, wet, dark brown, Silty, fine to medium SAND -2 -with clay -B3-1 0 SM ,.. -- -4 -:;rt i - ,.. -V / /1..' --------------------------------------B3-2 // /'/ -Becomes firm, saturated, dark blackish gray, Silty 8 89.8 31.4 ,_ 6 -// /i,, -,I/ /v CLAY with abundant organics and many pinholes. ,_ -// /i,, -// /i,, CL ,_ 8 -/ / /i,, -/ / /v // /v ,_ -~ //ii,, - //v ,.. 10 -I~ / /y -B3-3 //v -Becomes stiff, dark olive brown with few organics 11 --//y -/Vv 12 ~ /Vii,, - -/Vv - V !//ii,, --~ V!/v - -14 -~~~ -//ii,, B3-4 m :/!/v 4 - -!/i/y -Becomes soft ,... /v,, -16 -!/V,, --,,, /I.I BORING TERMINATED AT 16.5 FEET Groundwater encountered at 4 feet Figure A-3, Log of Boring B 3 LCGTS SAMPLE SYMBOLS 0 ... SAMPL ING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) §§ ... DISTURBED OR BAG SAMPLE liiiJ ... CHUNK SAMPLE J ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHOWN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION ANO AT THE DATE INDICATED, IT IS NOT WARRA~TEO TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS ANO TIMES. FIGURE A-10 PROJECT NO. 06796-22-01 ffi BORING B 4 >-Zw-'"' >--'"' (.!) I-I--'"' UJ~ 0 <c: Ou• DEPTH _J 3 SOIL Hzl-H, e:: '-' IN SAMPLE 0 C CLASS I-<J:u. U>u. ~ .... NO. :::c: z ELEV. (MSL.) 22 DATE COMPLETED 4/1/02 <l:1-'-z. FEET I-::J o::: en en Wu enZ H 0 (USCS) t-H3 c. HW _J e:: WenO >-a.. ol- (!) EQUIPMENT ffi A-300 ZUJ_J e:: '-' ;cZ ~e::e 0 C u MATERIAL DESCRIPTION -0 l/ vv ,I ~ vv I ALLUVIUM --vv ,I - V Vi/ ,I Soft, wet, dark brown, Silly CLAY ... 2 -m vv I -B4-1 vv I CL ... -vv ,I -~~ ✓i / -4 -/ vv I - / ~~ ,I --I~ -B4-2 vv ,I 16 -6 -!/V ,, -V/ ,, -Becomes stiff, saturated, dark olive brown, Sandy V !/ / ,I SILT --i V v ,, -!/ / y -8 -// y -// y --// /11 -I// /Y 10 V/ 1/,; I--~ --------------------------------------B4-3 -No recovery 10 I---CL -Becomes firm, dark olive tan, Sandy CLAY ... 12 -,---~ --14 -.% f- I----------------------------------------84-4 ~ CL 7 -16 --Becomes olive tan to light gray, Silty CLAY - TRENCH TERMINATED AT 16.5 FEET Groundwater encountered at 3.5 feet Figure A-4, Log of Boring B 4 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDAIRD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) ~ •.• DISTURBED OR BAG SAMPLE ~ ... CHUNK SAMPLE ! ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHO\JN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. FIGURE A-11 PROJECT NO 06796-22-0 I 0:: BORING B 5 >-LU zl.U,-,.. >-" t!) I-0 a: Ou• I-'"' w~ DEPTH ...J 3 SOIL Hzl-H . Q:: V IN SAMPLE 0 0 CLASS I-(Cl&.. (J)LL =>1-:I: z ELEV. (MSL.) 25 DA TE COMPLETED 4/J /02 <I:1-' ffi . NO. Ct::(/)(/) 1-z FEET I:; ::::, (USCS) a~ (/)UJ 0 I-H3 H1-...J a:: LJJ(/)0 >-a. Oz t!) EQUIPMENT m. A-300 ffi w~ o::'-' :Co Q. a::'-" a u MATERIAL DESCRIPTION ,-0 r1.; ,--SC ALLUVIUM -B5-1 v<// Loose, wet, light brown, Clayey SAND -2 ---------------------------------------... -~ -Becomes soft, dark brown, Silty CLAY - -4 -- --~ I -B5-2 CL -No recovery 11 -6 -- --~ - -8 -- --- ... 10 -z -B5-3 -No recovery 23 --. -~ - ~✓-~ --------------------------------------... 12 -B5-4 SC Loose, saruratcd, tan, brown, Clayey, fine to coarse -8 ✓ ✓·I; . ... -) / ·,~ I . __ SAND ______________________________ , I - , ; ,I/ -Becomes firm, saruratcd, ligh1 gray and tan, Sandy ... 14 -• ./LI -,) _, LI ML SILT with clay ,--r~ /;), -85-5 /I;'. 9 · vii -16 -_;,, ·1; - BORING TERMINATED AT 16.5 FEET Groundwater at 5 feet Figure A-5, Log of Boring B 5 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) ffli ... DISTURBED OR BAG SAMPLE ~ -•• CHUNK SAMPLE ~ ••• \JATER TABLE OR SEEPAGE ... NOTE: THE LOG OF SUBSURFACE CONDITIONS SHO',IN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT ~ARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. FIGURE A-12 PROJECT NO 06796-22-0 I 0:: BORING B 6 >-IJJ ZIJJ" >-" (.!) I-0 <J: Ou • I-" w.-: DEPTH ...J :::t SOIL ~zt H . a::"' IN SAMPLE 0 a CLASS <I: <I:' (/)u.. =>1-NO. ::c z ELEV. (MSL.) 32 DATE COMPLETED 4/1/02 o:: I-en r5 . 1-z FEET l=i ::::, (USCS) 1-(/):::t a~ <nw 0 wHo HI-...J a:: EQUIPMENT IR A-300 Z(l)...J >-Q. Oz (.!) wWa::, o::v l:o Q. 0::...., a u MA TERlAL DESCRJPTION -0 :-1. 1 ·l FILL --ll-1 SM Loose, wet, dark brown, Silty, fine lo medium SAND -86-1 -2 -// /i,, with some clay /,I /y ALLUVIUM --/ ,I /i,, I -/ ,I /y Soft, wet, dark olive brown, Silty CLAY -4 -// /it CL -/ ,I /v --i/i/ / 1 ✓· '·/---------------------------------------86-2 1/;; -Becomes loose, dark gray brown, Clayey, fine to 10 111.4 19.9 -6 --{// coarse SAND with silt --[(// -SC .... 8 -//. -v:// 0--~/}. - -10 -I {// -86-3 ,. __ -!-!S~l_b~o~E,_q>~~eJ '!!l~ ~ale! _________________ ,· I '7 1('1 .., 'lC: A -- I~ -Becomes stiff, wcl, light olive tan and green, Sandy --12 -CLAY -CL - -~ - -14 -----86-4 [0 16 -16 ---Becomes light olive green and gr.ay. fine to coarse SAND I BORING TERMINATED AT 16.5 FEET Groundwater al 3.5 feet Figure A-6, Log of Boring B 6 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) ~ ••. DISTURBED OR BAG SAMPLE ~ -.. CHUNK SAMPLE ~ ... WATER TABLE OR SEEPAGE .... NOTE: THE LOG OF SUBSURFACE CONDITIONS SHO\.IN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCAT IONS AND TIMES. FIGURE A-13 PROJECT NO. 06796-22-0J Q:: BORING B 7 >-IJJ Zw" >-,... (.!) I-0 <t Ou• ~~ wX DEPTH SAMPLE ...J :I SOIL Hzl-Q::'"' IN 0 0 CLASS I-<CLL zLL =>,-NO. ::c z ELEV. (MSL.) 44 DATE COMPLETED 4/1/02 <Cl-' w· 1-z FEET l::i ::) (USCS) a::(/)(/) a~ (/) UJ 0 I-H3 H,-....J Q:: EQUIPMENT W(l)O >-0.. Oz t!) fR A-300 Zw....J Q::'-' :Co ~o::~ 0 u MATERIAL DESCRIPTION ... 0 ~ ... -SM FILL I-fil Loose, wet, light tan brown, Silty , fine to medium ... 2 -SAND with clay I- 87-1 v·/·/: f---~---) ALLUVIUM .... I-4 -t// SC Loose, moist to slightly wet, dark brown, Clayey, fine - ;, /./ to coarse SAND ... ---------------------------------------87-2 I~ -Becomes stiff, light tan brown, fine 10 medjum 18 102.7 23.2 ... 6 -I-Sandy CLAY --I- -8 -z ? CL .... --½ ,- -10 ---------------------------------------87-3 ~~ /'/ 26 // -Becomes very stiff, saturated, light olive gray and --~~ /'/ .... // green, Silty CLAY -12 -/V /i,; ,-/V /i,; CL --/V /i,; ,... ~~ // 14 /i,; --/V /y - /V /y ... -1 <-.M --------------------------------------87-4 I 'l ~,t . -Becomes medium dense, saturated, light tan, Silty, i f--16 -ML I fine to medium SAND ,- I ------------------------------------, Becomes stiff, wet, olive tan, Clayey SILT BORING TERMINATED AT 16.5 FEET Groundwater at 8 feel Figure A-7, Log of Boring B 7 LCGTS SAMPLE SYMBOLS 0 ... SAMPLING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) ~ .•. DISTURBED OR BAG SAMPLE ~ -.. CHUNK SAMPLE ~ ..• \./ATER TABLE OR SEEPAGE - NOTE: THE LOG OF SUBSURFACE CONDITIONS SHO\.IN HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION AND AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS AND TIMES. FIGURE A-14 PROJECT NO 06796-22-01 0:: BORING B 8 >-IJJ ZIJJ"' §-; ,... (.!) I-0 <t Ou . w:-: DEPTH SAMPLE ...J ::I SOIL Hzf-o::'-' IN 0 □ CLASS f-<CIJ.. zLL =>1-NO. :c z ELEV. (MSL.) 46 DATE COMPLETED 4/1/02 <tt-" IJ.J • t-z FEET t-=> (USCS) O::u,U> 0~ (/)UJ H 0 l:uH5 H1-...J 0:: EQUIPMENT IR A-300 zU>...J >-a.. Oz (.!) w IJJtO 0::'"' Eo a.. 0::...., 0 u MATERIAL DESCRIPTION -0 --.1: 1 :1· SM FILL -B8-I Loose, moist, light tan, brown, Silly, fine 10 medium -2 -V vv LI \ SAND / .... II /V y /V I ALLUVIUM --/V I ~ I-/V i,,_ Soft, wet, dark brown, Silly CLAY -4 -/V y --/1/ I CL ... -/V I ~~ i,, ... B8-2 y -Becomes stiff, wet, dark tan and brown 11 92.5 30.5 -6 -~ I ... /V I --/!,.I I ,-~ vv -8 -/V I vv I ,- vv I --~ vv I ,-vv I -10 -// 1-:]:y::· --------------------------------------B8-3 16 108.0 23.0 - --Becomes medium dense, saturated, light tan brown, ... SM Silty, fine to medium SAND with trace clay -12 -:·1 :-,. ... --:1-·l ,- -14 -:r.t,. ,- --v~~ ------------------------------------ -B8-4 ~ :; CL -Becomes firm, wet, light brownish gray, Silly CLAY 6 -16 -- BORING TERMINATED AT 16.5 FEET Groundwater encountered at 3.5 feet Figure A-8, Log of Boring B 8 LCGTS SAMPLE SYMBOLS D ... SAMPL ING UNSUCCESSFUL IJ ... STANDARD PENETRATION TEST ■ ... DRIVE SAMPLE (UNDISTURBED) I!§ ... OISlURBEO OR BAG SAMPLE ~ ..• CHUNK SAMPLE J ... WATER TABLE OR SEEPAGE NOTE: THE LOG OF SUBSURFACE CONDITIONS SHQ',/N HEREON APPLIES ONLY AT THE SPECIFIC BORING OR TRENCH LOCATION ANO AT THE DATE INDICATED. IT IS NOT WARRANTED TO BE REPRESENTATIVE OF SUBSURFACE CONDITIONS AT OTHER LOCATIONS ANO TIMES. APPENDIX B Geocon Project No. T2754-22-04 -B- April 15, 2021 APPENDIX B LABORATORY TESTING We performed laboratory tests in accordance with current generally accepted test methods of ASTM International (ASTM) or other suggested procedures. We analyzed selected soil samples for in-situ density and moisture content, maximum dry density and optimum moisture content, water-soluble sulfate, R-value, and direct shear strength. The results of the laboratory tests are presented on Figures B-1 and B-2. Results of previous laboratory test results (Geocon, 2002) are presented on Figures B-3 and B-4. The in-place dry density and moisture content of the samples tested are presented on the boring logs in Appendix A. LABORATORY TEST RESULTS CHAMPIONS COURSE RENAVATIONS OMNI LA COSTA RESORT & SPA 2100 COTSA DEL MAR ROAD CARLSBAD, CALIFORNIA PST APRIL 2021 PROJECT NO. T2754-22-04 FIG B-1 X SUMMARY OF LABORATORY MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT TEST RESULTS ASTM D1557 Sample No. Description Maximum Dry Density (pcf) Optimum Moisture Content (% of dry wt.) B-2 @ 0-5’ Sandy CLAY (CL), dark brown 119.5 8.5 SUMMARY OF WATER-SOLUBLE SULFATE TEST RESULTS Sample No. Sulfate Content (%) B-5 @ 0-5’ 0.100 B-3 @ 0-5’ 1.390 Water-soluble sulfate determined by California Test 417. SUMMARY OF LABORATORY R-VALUE TEST RESULTS ASTM D2844 Sample No. R-Value B-4 @ 0-5’ 7 GEOCON W E S T, I N C. GEOTECHNICAL ENVIRONMENTAL MATERIALS 41571 CORNING PLACE. SUITE 101. MURRIETA. CA 92562-7065 PHONE 951-304-2300 FAX 951-304-2392 I I I I Project No.: T2754-22-04 2.98 Boring No. B2 Normal Strest (kip/ft2) 1 3 5 Sample No. B2@0-5 Peak Shear Stress (kip/ft²) 0.71 1.91 0.05 Depth (ft) 0-5 Shear Stress @ End of Test (ksf) 0.71 1.87 2.95 Sample Type:Ring Deformation Rate (in./min.)0.05 0.05 Soil Identification:Initial Sample Height (in.)1.0 1.0 1.0 Clayey Sand (SC) - dark brown Ring Inside Diameter (in.)2.375 2.375 2.375 Initial Moisture Content (%)8.6 8.6 8.6 Strength Parameters Initial Dry Density (pcf)108.0 108.0 108.1 41.2 41.5 Peak 163 29.6 Soil Height Before Shearing (in.) 1.2 1.2 1.2 C (psf)Initial Degree of Saturation (%) 41.3 Ultimate 161 29.3 Final Moisture Content (%) 17.7 12.7 DIRECT SHEAR TEST RESULTS CHAMPIONS COURSE RENOVATIONS OMNI LA COSTA RESOR T & SPA CARLSBAD, CALIFORNIAConsolidated Drained ASTM D-3080 Checked by: 15.8 Apr 21 Figure B2 0.0 1.0 2.0 3.0 4.0 5.0 0.0 1.0 2.0 3.0 4.0 5.0Shear Stress (ksf)Normal Stress (ksf) I/' / --- V v · / - / V • ■ ... 0 □ ~ r ~ GEOCON FIGURE B-3 APPENDIX B LABORATORY TESTING Laboratory tests were performed in accordance wi th generally accepted test methods of the American Society for Testing and Materials (ASTM) or other suggested procedures. Selected samples were tested for their in-situ dry density and moisture content, compaction characteristics, direct shear strength, water-soluble sulfate content, sieve analysis, pH and resistivity test. Results of the laboratory tests are presented below. In -situ dry density and moisture content arc presented on the boring logs in Appendix A. Sample o. B 1-J B7-I Sample No. 81-2 B6-2 B8-3 TABLE B-1 SUMMARY OF LABORATORY MAXIMUM DRY DENSITY ANO OPTIMUM MOISTURE CONTENT TEST RESULTS ASTM D 1557-00 Maximum Dry O ptimum Description Density (pd) Moisture Content (% d ry wt.) Dark brown, Silty fine to coarse SAND 127.4 10.J with clay Dark brown, Silty, fine to medium SAND 126.6 9.9 with clay TABLE B-11 SUMMARY OF LABORATORY DIRECT SHEAR TEST RESULTS ASTM D 3080-98 Dry Density Moisture Content Unit Cohesion Angle of Shear (pc() (%) (ps() Resistance (degrees) 102.3 27.2 450 28 111.4 19.9 280 38 108.0 23.0 500 38 Projecl No. 06796-22-0 L -B-1 -Apnl 30, 2002 Revised July 17, 2002 FIGURE B-4 TABLE 8-111 SUMMARY OF LABORATORY WATER-SOLUBLE SULFATE TEST RESULTS CALIFORNIA TEST NO. 417 Sample No. Water-Soluble Sulfate(%) Sulfate Exposure (UBC Table 19-A-4) Bl-1 0.196 I "Moderate" B8-1 0.174 "Moderale" TABLE B-IV SUMMARY OF LABORATORY SIEVE ANALYSIS TEST RESULTS ASTM D 1140 Sieve Analysis ASTM D-42.2 Sample No. 82-3 Sample o. B4-2 (Sieve Size) (% Passing) (% Passing) No.4 100 100 No. 8 96 100 No. 16 91 99 No. 30 84 98 No. 50 75 92 No. 100 58 66 No. 200 48 52 TABLE B-V SUMMARY OF LABORATORY RESISTIVITY AND POTENTIAL OF HYDROGEN (pH) TEST RESULTS CALIFORNIA TEST NO. 643 Sample No. Resistance (ohm cm} B8-1 427 P rOJCCl No. 06796-22-0 I -B-2 - pH 8.0 Apnl 30. 2002 Revised July 17. 2002 APPENDIX C Geocon Project No. T2754-22-04 - C - April 15, 2021 APPENDIX C RECOMMENDED GRADING SPECIFICATIONS FOR CHAMPIONS COUSRE RENOVATIONS OMNI LA COSTA RESOR T & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA PROJECT NO. T2754-22-04 GI rev. 07/2015 RECOMMENDED GRADING SPECIFICATIONS 1. GENERAL 1.1 These Recommended Grading Specifications shall be used in conjunction with the Geotechnical Report for the project prepared by Geocon. The recommendations contained in the text of the Geotechnical Report are a part of the earthwork and grading specifications and shall supersede the provisions contained hereinafter in the case of conflict. 1.2 Prior to the commencement of grading, a geotechnical consultant (Consultant) shall be employed for the purpose of observing earthwork procedures and testing the fills for substantial conformance with the recommendations of the Geotechnical Report and these specifications. The Consultant should provide adequate testing and observation services so that they may assess whether, in their opinion, the work was performed in substantial conformance with these specifications. It shall be the responsibility of the Contractor to assist the Consultant and keep them apprised of work schedules and changes so that personnel may be scheduled accordingly. 1.3 It shall be the sole responsibility of the Contractor to provide adequate equipment and methods to accomplish the work in accordance with applicable grading codes or agency ordinances, these specifications and the approved grading plans. If, in the opinion of the Consultant, unsatisfactory conditions such as questionable soil materials, poor moisture condition, inadequate compaction, and/or adverse weather result in a quality of work not in conformance with these specifications, the Consultant will be empowered to reject the work and recommend to the Owner that grading be stopped until the unacceptable conditions are corrected. 2. DEFINITIONS 2.1 Owner shall refer to the owner of the property or the entity on whose behalf the grading work is being performed and who has contracted with the Contractor to have grading performed. 2.2 Contractor shall refer to the Contractor performing the site grading work. 2.3 Civil Engineer or Engineer of Work shall refer to the California licensed Civil Engineer or consulting firm responsible for preparation of the grading plans, surveying and verifying as-graded topography. 2.4 Consultant shall refer to the soil engineering and engineering geology consulting firm retained to provide geotechnical services for the project. GI rev. 07/2015 2.5 Soil Engineer shall refer to a California licensed Civil Engineer retained by the Owner, who is experienced in the practice of geotechnical engineering. The Soil Engineer shall be responsible for having qualified representatives on-site to observe and test the Contractor's work for conformance with these specifications. 2.6 Engineering Geologist shall refer to a California licensed Engineering Geologist retained by the Owner to provide geologic observations and recommendations during the site grading. 2.7 Geotechnical Report shall refer to a soil report (including all addenda) which may include a geologic reconnaissance or geologic investigation that was prepared specifically for the development of the project for which these Recommended Grading Specifications are intended to apply. 3. MATERIALS 3.1 Materials for compacted fill shall consist of any soil excavated from the cut areas or imported to the site that, in the opinion of the Consultant, is suitable for use in construction of fills. In general, fill materials can be classified as soil fills, soil-rock fills or rock fills, as defined below. 3.1.1 Soil fills are defined as fills containing no rocks or hard lumps greater than 12 inches in maximum dimension and containing at least 40 percent by weight of material smaller than ¾ inch in size. 3.1.2 Soil-rock fills are defined as fills containing no rocks or hard lumps larger than 4 feet in maximum dimension and containing a sufficient matrix of soil fill to allow for proper compaction of soil fill around the rock fragments or hard lumps as specified in Paragraph 6.2. Oversize rock is defined as material greater than 12 inches. 3.1.3 Rock fills are defined as fills containing no rocks or hard lumps larger than 3 feet in maximum dimension and containing little or no fines. Fines are defined as material smaller than ¾ inch in maximum dimension. The quantity of fines shall be less than approximately 20 percent of the rock fill quantity. 3.2 Material of a perishable, spongy, or otherwise unsuitable nature as determined by the Consultant shall not be used in fills. 3.3 Materials used for fill, either imported or on-site, shall not contain hazardous materials as defined by the California Code of Regulations, Title 22, Division 4, Chapter 30, Articles 9 GI rev. 07/2015 and 10; 40CFR; and any other applicable local, state or federal laws. The Consultant shall not be responsible for the identification or analysis of the potential presence of hazardous materials. However, if observations, odors or soil discoloration cause Consultant to suspect the presence of hazardous materials, the Consultant may request from the Owner the termination of grading operations within the affected area. Prior to resuming grading operations, the Owner shall provide a written report to the Consultant indicating that the suspected materials are not hazardous as defined by applicable laws and regulations. 3.4 The outer 15 feet of soil-rock fill slopes, measured horizontally, should be composed of properly compacted soil fill materials approved by the Consultant. Rock fill may extend to the slope face, provided that the slope is not steeper than 2:1 (horizontal:vertical) and a soil layer no thicker than 12 inches is track-walked onto the face for landscaping purposes. This procedure may be utilized provided it is acceptable to the governing agency, Owner and Consultant. 3.5 Samples of soil materials to be used for fill should be tested in the laboratory by the Consultant to determine the maximum density, optimum moisture content, and, where appropriate, shear strength, expansion, and gradation characteristics of the soil. 3.6 During grading, soil or groundwater conditions other than those identified in the Geotechnical Report may be encountered by the Contractor. The Consultant shall be notified immediately to evaluate the significance of the unanticipated condition 4. CLEARING AND PREPARING AREAS TO BE FILLED 4.1 Areas to be excavated and filled shall be cleared and grubbed. Clearing shall consist of complete removal above the ground surface of trees, stumps, brush, vegetation, man-made structures, and similar debris. Grubbing shall consist of removal of stumps, roots, buried logs and other unsuitable material and shall be performed in areas to be graded. Roots and other projections exceeding 1½ inches in diameter shall be removed to a depth of 3 feet below the surface of the ground. Borrow areas shall be grubbed to the extent necessary to provide suitable fill materials. 4.2 Asphalt pavement material removed during clearing operations should be properly disposed at an approved off-site facility or in an acceptable area of the project evaluated by Geocon and the property owner. Concrete fragments that are free of reinforcing steel may be placed in fills, provided they are placed in accordance with Section 6.2 or 6.3 of this document. GI rev. 07/2015 4.3 After clearing and grubbing of organic matter and other unsuitable material, loose or porous soils shall be removed to the depth recommended in the Geotechnical Report. The depth of removal and compaction should be observed and approved by a representative of the Consultant. The exposed surface shall then be plowed or scarified to a minimum depth of 6 inches and until the surface is free from uneven features that would tend to prevent uniform compaction by the equipment to be used. 4.4 Where the slope ratio of the original ground is steeper than 5:1 (horizontal:vertical), or where recommended by the Consultant, the original ground should be benched in accordance with the following illustration. TYPICAL BENCHING DETAIL Remove All Unsuitable Material As Recommended By Consultant Finish Grade Original Ground Finish Slope Surface Slope To Be Such That Sloughing Or Sliding Does Not Occur Varies “B” See Note 1 No Scale See Note 2 1 2 DETAIL NOTES: (1) Key width "B" should be a minimum of 10 feet, or sufficiently wide to permit complete coverage with the compaction equipment used. The base of the key should be graded horizontal, or inclined slightly into the natural slope. (2) The outside of the key should be below the topsoil or unsuitable surficial material and at least 2 feet into dense formational material. Where hard rock is exposed in the bottom of the key, the depth and configuration of the key may be modified as approved by the Consultant. 4.5 After areas to receive fill have been cleared and scarified, the surface should be moisture conditioned to achieve the proper moisture content, and compacted as recommended in Section 6 of these specifications. GI rev. 07/2015 5. COMPACTION EQUIPMENT 5.1 Compaction of soil or soil-rock fill shall be accomplished by sheepsfoot or segmented-steel wheeled rollers, vibratory rollers, multiple-wheel pneumatic-tired rollers, or other types of acceptable compaction equipment. Equipment shall be of such a design that it will be capable of compacting the soil or soil-rock fill to the specified relative compaction at the specified moisture content. 5.2 Compaction of rock fills shall be performed in accordance with Section 6.3. 6. PLACING, SPREADING AND COMPACTION OF FILL MATERIAL 6.1 Soil fill, as defined in Paragraph 3.1.1, shall be placed by the Contractor in accordance with the following recommendations: 6.1.1 Soil fill shall be placed by the Contractor in layers that, when compacted, should generally not exceed 8 inches. Each layer shall be spread evenly and shall be thoroughly mixed during spreading to obtain uniformity of material and moisture in each layer. The entire fill shall be constructed as a unit in nearly level lifts. Rock materials greater than 12 inches in maximum dimension shall be placed in accordance with Section 6.2 or 6.3 of these specifications. 6.1.2 In general, the soil fill shall be compacted at a moisture content at or above the optimum moisture content as determined by ASTM D 1557. 6.1.3 When the moisture content of soil fill is below that specified by the Consultant, water shall be added by the Contractor until the moisture content is in the range specified. 6.1.4 When the moisture content of the soil fill is above the range specified by the Consultant or too wet to achieve proper compaction, the soil fill shall be aerated by the Contractor by blading/mixing, or other satisfactory methods until the moisture content is within the range specified. 6.1.5 After each layer has been placed, mixed, and spread evenly, it shall be thoroughly compacted by the Contractor to a relative compaction of at least 90 percent. Relative compaction is defined as the ratio (expressed in percent) of the in-place dry density of the compacted fill to the maximum laboratory dry density as determined in accordance with ASTM D 1557. Compaction shall be continuous over the entire area, and compaction equipment shall make sufficient passes so that the specified minimum relative compaction has been achieved throughout the entire fill. GI rev. 07/2015 6.1.6 Where practical, soils having an Expansion Index greater than 50 should be placed at least 3 feet below finish pad grade and should be compacted at a moisture content generally 2 to 4 percent greater than the optimum moisture content for the material. 6.1.7 Properly compacted soil fill shall extend to the design surface of fill slopes. To achieve proper compaction, it is recommended that fill slopes be over-built by at least 3 feet and then cut to the design grade. This procedure is considered preferable to track-walking of slopes, as described in the following paragraph. 6.1.8 As an alternative to over-building of slopes, slope faces may be back-rolled with a heavy-duty loaded sheepsfoot or vibratory roller at maximum 4-foot fill height intervals. Upon completion, slopes should then be track-walked with a D-8 dozer or similar equipment, such that a dozer track covers all slope surfaces at least twice. 6.2 Soil-rock fill, as defined in Paragraph 3.1.2, shall be placed by the Contractor in accordance with the following recommendations: 6.2.1 Rocks larger than 12 inches but less than 4 feet in maximum dimension may be incorporated into the compacted soil fill, but shall be limited to the area measured 15 feet minimum horizontally from the slope face and 5 feet below finish grade or 3 feet below the deepest utility, whichever is deeper. 6.2.2 Rocks or rock fragments up to 4 feet in maximum dimension may either be individually placed or placed in windrows. Under certain conditions, rocks or rock fragments up to 10 feet in maximum dimension may be placed using similar methods. The acceptability of placing rock materials greater than 4 feet in maximum dimension shall be evaluated during grading as specific cases arise and shall be approved by the Consultant prior to placement. 6.2.3 For individual placement, sufficient space shall be provided between rocks to allow for passage of compaction equipment. 6.2.4 For windrow placement, the rocks should be placed in trenches excavated in properly compacted soil fill. Trenches should be approximately 5 feet wide and 4 feet deep in maximum dimension. The voids around and beneath rocks should be filled with approved granular soil having a Sand Equivalent of 30 or greater and should be compacted by flooding. Windrows may also be placed utilizing an "open-face" method in lieu of the trench procedure, however, this method should first be approved by the Consultant. GI rev. 07/2015 6.2.5 Windrows should generally be parallel to each other and may be placed either parallel to or perpendicular to the face of the slope depending on the site geometry. The minimum horizontal spacing for windrows shall be 12 feet center-to-center with a 5-foot stagger or offset from lower courses to next overlying course. The minimum vertical spacing between windrow courses shall be 2 feet from the top of a lower windrow to the bottom of the next higher windrow. 6.2.6 Rock placement, fill placement and flooding of approved granular soil in the windrows should be continuously observed by the Consultant. 6.3 Rock fills, as defined in Section 3.1.3, shall be placed by the Contractor in accordance with the following recommendations: 6.3.1 The base of the rock fill shall be placed on a sloping surface (minimum slope of 2 percent). The surface shall slope toward suitable subdrainage outlet facilities. The rock fills shall be provided with subdrains during construction so that a hydrostatic pressure buildup does not develop. The subdrains shall be permanently connected to controlled drainage facilities to control post-construction infiltration of water. 6.3.2 Rock fills shall be placed in lifts not exceeding 3 feet. Placement shall be by rock trucks traversing previously placed lifts and dumping at the edge of the currently placed lift. Spreading of the rock fill shall be by dozer to facilitate seating of the rock. The rock fill shall be watered heavily during placement. Watering shall consist of water trucks traversing in front of the current rock lift face and spraying water continuously during rock placement. Compaction equipment with compactive energy comparable to or greater than that of a 20-ton steel vibratory roller or other compaction equipment providing suitable energy to achieve the required compaction or deflection as recommended in Paragraph 6.3.3 shall be utilized. The number of passes to be made should be determined as described in Paragraph 6.3.3. Once a rock fill lift has been covered with soil fill, no additional rock fill lifts will be permitted over the soil fill. 6.3.3 Plate bearing tests, in accordance with ASTM D 1196, may be performed in both the compacted soil fill and in the rock fill to aid in determining the required minimum number of passes of the compaction equipment. If performed, a minimum of three plate bearing tests should be performed in the properly compacted soil fill (minimum relative compaction of 90 percent). Plate bearing tests shall then be performed on areas of rock fill having two passes, four passes and six passes of the compaction equipment, respectively. The number of passes required for the rock fill shall be determined by comparing the results of the plate bearing tests for the soil fill and the rock fill and by evaluating the deflection GI rev. 07/2015 variation with number of passes. The required number of passes of the compaction equipment will be performed as necessary until the plate bearing deflections are equal to or less than that determined for the properly compacted soil fill. In no case will the required number of passes be less than two. 6.3.4 A representative of the Consultant should be present during rock fill operations to observe that the minimum number of “passes” have been obtained, that water is being properly applied and that specified procedures are being followed. The actual number of plate bearing tests will be determined by the Consultant during grading. 6.3.5 Test pits shall be excavated by the Contractor so that the Consultant can state that, in their opinion, sufficient water is present and that voids between large rocks are properly filled with smaller rock material. In-place density testing will not be required in the rock fills. 6.3.6 To reduce the potential for “piping” of fines into the rock fill from overlying soil fill material, a 2-foot layer of graded filter material shall be placed above the uppermost lift of rock fill. The need to place graded filter material below the rock should be determined by the Consultant prior to commencing grading. The gradation of the graded filter material will be determined at the time the rock fill is being excavated. Materials typical of the rock fill should be submitted to the Consultant in a timely manner, to allow design of the graded filter prior to the commencement of rock fill placement. 6.3.7 Rock fill placement should be continuously observed during placement by the Consultant. 7. SUBDRAINS 7.1 The geologic units on the site may have permeability characteristics and/or fracture systems that could be susceptible under certain conditions to seepage. The use of canyon subdrains may be necessary to mitigate the potential for adverse impacts associated with seepage conditions. Canyon subdrains with lengths in excess of 500 feet or extensions of existing offsite subdrains should use 8-inch-diameter pipes. Canyon subdrains less than 500 feet in length should use 6-inch-diameter pipes. GI rev. 07/2015 TYPICAL CANYON DRAIN DETAIL 7.2 Slope drains within stability fill keyways should use 4-inch-diameter (or lager) pipes. NATURAL GROUND _,,,,/.,,--- SEE DETAL BELOW NOTES: 1 ...... 8-lNCH DIAMETER, SCHEDULE 80 PVC PERFORATED PIPE FOR FILLS IN EXCESS OF 100-FEET IN DEPTH OR A PIPE LENGTH OF LONGER THAN 500 FEET. 2 ...... 6-INCH DIAMETER, SCHEDULE 40 PVC PERFORATED PIPE FOR FILLS LESS THAN 100-FEET IN DEPTH OR A PIPE LENGTH SHORTER THAN 500 FEET. ., .,,.,,.,, .,...,,.,,,,,..,,,. BEDROCK NOTE: FINAL 20' OF PIPE AT Olm.ET SHALL BE NON-PERFORATED. 9 CUBIC FEET I FOOT OF OPEN GRADED GRAVEL SURROUNDED BY MIRAFI 140NC (OR EQUIVALENl) FILTER FABRIC NO SCALE GI rev. 07/2015 TYPICAL STABILITY FILL DETAIL 7.3 The actual subdrain locations will be evaluated in the field during the remedial grading operations. Additional drains may be necessary depending on the conditions observed and the requirements of the local regulatory agencies. Appropriate subdrain outlets should be evaluated prior to finalizing 40-scale grading plans. 7.4 Rock fill or soil-rock fill areas may require subdrains along their down-slope perimeters to mitigate the potential for buildup of water from construction or landscape irrigation. The subdrains should be at least 6-inch-diameter pipes encapsulated in gravel and filter fabric. Rock fill drains should be constructed using the same requirements as canyon subdrains. DETAIL FORMA TIONAL MATERIAL 1 ..•.. EXCAVATE BACKCUT AT 1:1 INCUNATION (Ui'LESS OTHERWISE NOTED~ 2 .... .BASE OF STABILITY FILL TO BE 3 FEET INTO FORMATIONAL MATERIAL, SLOPING A MINIMUM 5')1, INTO SLOPE. 3 ..... STABIUTY FLL TO BE COMF'OSED OF PROPEFa. Y COMPACTED GRANLA.AR SOIL. 4 ..... CHIMNEY DRAINS TO BE APPROVED PREFABRICATED CHIMNEY DRAIN PANas (MIRADRAIN G200N OR EQUIVALENTI SPACED AF'PROXIMATELY 20 FEET CENTER TO CENTER ANO 4 FEETWIDE. CLOSER SPACING MAY BE REQUIRED IF SEEPAGE IS ENCOUNTERED. 5 ..... Fll TER MATERIAL TO BE 31'4-INCH, OPEN-GRADED CRUSHED ROCK ENCLOSED IN APPROVED FL TER FABAIC (MIRAFl 140NCi 6 ..... COLLECTOR PIPE TO BE 4-INCH MINIMUM DIAMETER, PERFORATED, THICK-WAULED PVC SCI-IEDULE 40 OR EQUIVALENT, AND SI.OPEC TO CRAIN AT 1 PERCENT t.lNMUM TO APPROVED ounET. NO SCALE GI rev. 07/2015 7.5 Prior to outletting, the final 20-foot segment of a subdrain that will not be extended during future development should consist of non-perforated drainpipe. At the non-perforated/ perforated interface, a seepage cutoff wall should be constructed on the downslope side of the pipe. TYPICAL CUT OFF WALL DETAIL 7.6 Subdrains that discharge into a natural drainage course or open space area should be provided with a permanent headwall structure. FRONT VIEW SIDE VIEW ' CONCRETE CUT-OFF WAIJ. CONCRETE CUT-OFF WAIJ. SOLID SUBDRAJN PIPE / NO SCALE 6" MIN. (TYP) PE•RFoRATED SUBORA1N PIPE . . . . . 6" MIN. (TYP) NO SCALE GI rev. 07/2015 TYPICAL HEADWALL DETAIL 7.7 The final grading plans should show the location of the proposed subdrains. After completion of remedial excavations and subdrain installation, the project civil engineer should survey the drain locations and prepare an “as-built” map showing the drain locations. The final outlet and connection locations should be determined during grading operations. Subdrains that will be extended on adjacent projects after grading can be placed on formational material and a vertical riser should be placed at the end of the subdrain. The grading contractor should consider videoing the subdrains shortly after burial to check proper installation and functionality. The contractor is responsible for the performance of the drains. FRONT VIEW SIDE VIEW 8"0R8" SUlDRAIN CONCRETE HEADWALL 8"0RB" SUBORAIN ~ 24• NOTE: HEADWALL SHOULD ounET AT TOE OF FILL SLOPE OR INTO CONTROLLED SURFACE DRAINAGE -::--:.-: :.r4~---. :~ . NO SCALE 12" NO SCALE GI rev. 07/2015 8. OBSERVATION AND TESTING 8.1 The Consultant shall be the Owner’s representative to observe and perform tests during clearing, grubbing, filling, and compaction operations. In general, no more than 2 feet in vertical elevation of soil or soil-rock fill should be placed without at least one field density test being performed within that interval. In addition, a minimum of one field density test should be performed for every 2,000 cubic yards of soil or soil-rock fill placed and compacted. 8.2 The Consultant should perform a sufficient distribution of field density tests of the compacted soil or soil-rock fill to provide a basis for expressing an opinion whether the fill material is compacted as specified. Density tests shall be performed in the compacted materials below any disturbed surface. When these tests indicate that the density of any layer of fill or portion thereof is below that specified, the particular layer or areas represented by the test shall be reworked until the specified density has been achieved. 8.3 During placement of rock fill, the Consultant should observe that the minimum number of passes have been obtained per the criteria discussed in Section 6.3.3. The Consultant should request the excavation of observation pits and may perform plate bearing tests on the placed rock fills. The observation pits will be excavated to provide a basis for expressing an opinion as to whether the rock fill is properly seated and sufficient moisture has been applied to the material. When observations indicate that a layer of rock fill or any portion thereof is below that specified, the affected layer or area shall be reworked until the rock fill has been adequately seated and sufficient moisture applied. 8.4 A settlement monitoring program designed by the Consultant may be conducted in areas of rock fill placement. The specific design of the monitoring program shall be as recommended in the Conclusions and Recommendations section of the project Geotechnical Report or in the final report of testing and observation services performed during grading. 8.5 We should observe the placement of subdrains, to check that the drainage devices have been placed and constructed in substantial conformance with project specifications. 8.6 Testing procedures shall conform to the following Standards as appropriate: 8.6.1 Soil and Soil-Rock Fills: 8.6.1.1 Field Density Test, ASTM D 1556, Density of Soil In-Place By the Sand-Cone Method. GI rev. 07/2015 8.6.1.2 Field Density Test, Nuclear Method, ASTM D 6938, Density of Soil and Soil-Aggregate In-Place by Nuclear Methods (Shallow Depth). 8.6.1.3 Laboratory Compaction Test, ASTM D 1557, Moisture-Density Relations of Soils and Soil-Aggregate Mixtures Using 10-Pound Hammer and 18-Inch Drop. 8.6.1.4. Expansion Index Test, ASTM D 4829, Expansion Index Test. 9. PROTECTION OF WORK 9.1 During construction, the Contractor shall properly grade all excavated surfaces to provide positive drainage and prevent ponding of water. Drainage of surface water shall be controlled to avoid damage to adjoining properties or to finished work on the site. The Contractor shall take remedial measures to prevent erosion of freshly graded areas until such time as permanent drainage and erosion control features have been installed. Areas subjected to erosion or sedimentation shall be properly prepared in accordance with the Specifications prior to placing additional fill or structures. 9.2 After completion of grading as observed and tested by the Consultant, no further excavation or filling shall be conducted except in conjunction with the services of the Consultant. 10. CERTIFICATIONS AND FINAL REPORTS 10.1 Upon completion of the work, Contractor shall furnish Owner a certification by the Civil Engineer stating that the lots and/or building pads are graded to within 0.1 foot vertically of elevations shown on the grading plan and that all tops and toes of slopes are within 0.5 foot horizontally of the positions shown on the grading plans. After installation of a section of subdrain, the project Civil Engineer should survey its location and prepare an as-built plan of the subdrain location. The project Civil Engineer should verify the proper outlet for the subdrains and the Contractor should ensure that the drain system is free of obstructions. 10.2 The Owner is responsible for furnishing a final as-graded soil and geologic report satisfactory to the appropriate governing or accepting agencies. The as-graded report should be prepared and signed by a California licensed Civil Engineer experienced in geotechnical engineering and by a California Certified Engineering Geologist, indicating that the geotechnical aspects of the grading were performed in substantial conformance with the Specifications or approved changes to the Specifications. Project No. T2754-22-04 October 10, 2022 REVISED November 21, 2022 LC Investments 2010, LLC d/b/a Omni La Costa Resort & Spa 4001 Maple Avenue, Suite 300 Dallas, Texas 75219 Attention: Mr. Clint Gulick Subject: GEOTECHNICAL RESPONSE GEOTECHNICAL REPORT REVIEW LETTER DATED SEPTEMBER 28, 2022 OMNI LA COSTA GOLF COURSE GRADING PERMIT NO. GR2022-0038, PROJECT ID: SUP2022-0001 CARLSBAD, CALIFORNIA References: 1. Geotechnical Report Review, Omni La Costa Golf Course (1st review) dated September 28, 2022, prepared by the City of Carlsbad. 2. Rough Grading Plan for Omni Resort Golf Course, Sheets 1 through 22, dated September 1, 2022, prepared by O’Day Consultants 3. Limited Geotechnical Investigation, Champions Course Renovations, Omni La Costa Resort & Spa, 2100 Costa Del Mar Road, Carlsbad, California, Project T2754- 22-04, dated April 15, 2021, prepared by Geocon West, Inc. Dear Mr. Gulick: This response letter has been prepared to provide geotechnical responses to report review questions presented in the City of Carlsbad Geotechnical Report Review letter dated September 28, 2022 (Reference1) with respect to the Limited Geotechnical Investigation report prepared by Geocon West, Inc. (Geocon) dated April 15, 2022 (Reference 3). This provides an item-by-item response to the review comments. Reference 1 is attached herein for ease of reference. This response has been revised to correct a typo in Geocon’s response to Comment 9. Comment 1: Please review the most current grading plan for the project and provide any additional geotechnical recommendations or modifications to the geotechnical report, as necessary. Response 1: Geocon has reviewed the grading plans (Reference 2) which depict the proposed improvements to include: realignment of cart paths, filling of the pond in the northern portion of the Course; cuts and fills of 5 feet or less to level some areas of the site and to raise other areas; and construction of three cart path and foot bridges that will span 25 feet or less. Geocon has considered the final proposed improvements depicted on reference 2 with respect to the Limited Geotechnical GEOCON W E S T, I N C. GEOTECHNICA L ■ ENVIRONMENTAL ■ MATERIALS °' 41571 Corning Ploce, Suite l 01 ■ Murrieto, Colilornio 92562-7065 ■ Telephone 951.304.2300 ■ Fox 951 .304.2392 Geocon Project No. T2754-22-04 - 2 - REVISED November 21, 2022 Investigation report (Reference 3) and the expected improvements are generally similar to those proposed at the time of Reference 3 in 2021 with the exception that no retaining walls are proposed on the plans. Reference 3 remains applicable to the project unless superseded herein. Comment 2: Please provide a statement addressing the potential impact of the project on adjacent properties from a geotechnical standpoint. Response 2: The proposed improvements will be constructed within the existing golf course and do not pose a hazard to adjacent properties from a geotechnical standpoint. Comment 3: Please provide an updated “Boring Location Map” utilizing a reduced version of the grading plan for the project as a base map but at a sufficiently large scale to clearly show (at a minimum): a) the existing limits of the golf course, individual fairways, drainages, and water hazards, etc., and b) the locations of subsurface exploration. Please note that the “Boring Location map” presented in the submitted report consists of a Google aerial photograph of the site that is on an 8.5x11” sheet and is at a significantly small scale (approximately 1”=1230’) that results in difficulty showing the actual locations of the subsurface exploration with respect to the course. Please produce a map at a scale that is sufficiently large to clearly distinguish the fairways and other features of the golf course and show the specific locations of the borings on the golf course; a sheet larger than 8.5x11” will likely be necessary to increase the legibility and show all information. Response 3: We have utilized the referenced grading plans (Reference 2) Sheets 4 through 22 as a base map for our Geologic Map presented herein as Figures 1 through 19. This provides the information at a scale of approximately 1”=93’ when printed on 11 X 17 sheets. The grading plans depict the existing conditions and the proposed improvements. Comment 4: Please clarify the range in depth of the existing unsuitable fill and young alluvium for the areas of the proposed cart paths, bridges, and retaining wall. Response 4: The depth of fill over alluvium is presented on the Geologic Map next to each boring location for ease of reference. Generally, based on the boring data, a majority of the golf course has less than 3 feet of previously placed fill over alluvium. Deeper fill is expected within tee areas, bunker berms, and hills within the fairways. The improvements proposed for this project include the realignment of cart paths; the flattening of topography in some localized areas within the Champions Course to remove small hills and straighten the front of slopes along the perimeter of the course; and the construction of three 25 ft long cart path or foot bridges. The bridges are expected to be supported on spread footing foundations. No retaining walls are proposed or depicted on the plans. Geocon Project No. T2754-22-04 - 3 - REVISED November 21, 2022 Geocon recommends that the fill and upper, unsuitable alluvium be removed to expose competent alluvium resulting in at least 2 feet of engineered fill beneath the new improvements. Please see section 7.5 in the referenced Limited Geotechnical Investigation report. Comment 5: As the site is described as underlain by young alluvium and there is no consolidation testing reported, please provide the basis for the values of potential settlement (total and differential) for new structures and improvements that are provided in the report. Response 5: Planned improvements are lightly loaded structures (on the order of 1,500 psf maximum bearing pressure) with a minimum of 2 feet of compacted fill beneath small footings. Typical settlement evaluation was performed utilizing static settlement methods (Schmertmann). Since loading is light and footings are relatively small, the loads will mostly be supported within compacted fill. Only minor loads will be imposed on saturated clays at depth. Therefore, long term consolidation settlement evaluation was not considered necessary. Comment 6: The report indicates liquefaction may be a design consideration for the proposed bridges and the retaining wall associated with the project. Please further address and clarify the potential for liquefaction relative to the proposed project and provide recommendations to mitigate, as necessary. Response 6: There are no retaining walls planned for this project. Slopes at bridges are 2 to 5 feet high, bridges are single span, lightly loaded and not particularly settlement sensitive. Therefore, incorporation of liquefaction settlements or lateral movements are considered necessary. Following a large earthquake event, releveling may be required. Comment 7: Please clarify the foundation recommendations for the supports for the proposed bridges. Response 7: The three proposed bridges will be approximately 25-foot-long single spans and will be either prefabricated or cast in place founded on shallow spread footing foundations. Section 7.7 provides foundation recommendations. In addition, the following is recommended: Where bridge footings are located next to a descending 3:1 (horizontal:vertical) fill slope or steeper, the foundations should be extended to a depth where the bottom outside edge of the footing is at least 7 feet horizontally from the face of slope. Comment 8: Please provide horizontal setback distance from adjacent slopes for foundations associated with the proposed bridges and the retaining wall. Response 8: No retaining walls are proposed. The three bridges are proposed in areas where the topography is relatively flat with no significant slopes in proximity to the bridge locations. The streams Geocon Project No. T2754-22-04 - 4 - REVISED November 21, 2022 which the bridges span are 2 to 5 feet deep with fairly steep slopes ranging from vertical to approximately 1;1 (h:v). The additional recommendation provided in Response No. 7 addresses slope setbacks. Comment 9: Please address if creep load should be applied to the foundations for the proposed bridges located adjacent to sloping ground: provide lateral creep load, as necessary. Response 9: Slopes are 2 to 5 feet, bridges are single span, lightly loaded and not particularly settlement sensitive. Therefore, evaluation and incorporation of creep loads are considered unnecessary. Comment 10: Please provide any recommendations to address the relative shallow groundwater with respect to the foundations for the proposed bridges or retaining wall, as necessary. Response 10: There are no retaining walls proposed for this project. Groundwater is shallow at the site and bridge foundation excavations could encounter groundwater. If encountered, groundwater should be pumped from the excavation and the excavation bottom stabilized if not firm and unyielding as with typical grading operations. Comment 11: Please clarify if reinforcing is recommended for all hardscape improvements due to the expansive soils and underlying young alluvium. Response 11: Per Section 7.8.1 of the referenced Limited Geotechnical Investigation report, Geocon recommends that concrete flatwork be reinforced with No. 3 bars placed 24 inches on center. Comment 12: As the results of Expansion Index testing presented in the report indicate a medium expansion potential (EI=74 to 78), please provide recommendations as necessary and a statement that the proposed foundation system/slabs-on-grade will meet the requirements of section 1808.6 of the 2019 California Building Code. As soils with expansion index (EI) over 20 are considered expansive and require mitigation in accordance with sections 1803.5.3 and 1808.6 of the 2019 CBC, please indicate the method of section 1808.6 (1808.6.1 through 1808.6.4) that is being recommended to satisfy the requirement and provide the Effective Plasticity Index and any other parameters for foundation design in accordance with WRI/CRSI Design of Slab-on-Ground floors, as necessary. Response 12: Since the expansive soils will not be removed, stabilization will be required. Stabilization will consist of removing existing expansive soils beneath footings, wetting (presaturating) and placing as compacted fill. No slabs-on-grade are proposed for this project. Comment 13: Soluble sulfate testing presented in the report indicates both moderate and severs [sic] sulfate exposure (S1 and S2). Consequently, please provide recommendations for sulfate resistant Geocon Project No. T2754-22-04 - 5 - REVISED November 21, 2022 concrete (compressive strength, w/c ratio, type cement) consistent with the 2019 California Building Code and ACI 318, Tables 4.2.1 and 4.3.1 assuming “Severe” (S2) exposure class. Response 13: The Exposure Class with corresponding Cement Type, Water to Cement Ratio, and Minimum Compressive Strength are presented in Table 7.2.5 of the referenced Limited Geotechnical Investigation report. Comment 14: Please provide the OSHA Type Soil (A, B, or C) and associated temporary slope inclination (H:V) that the construction plans and contractors should adhere to during the design and construction of the development. Response 14: Geocon presents recommendations for temporary excavations in Section 7.4 of Reference 3. The site soils should be considered as Class C with the addition of saturation. Conditions can vary within excavations and Geocon may not be present during all site work, therefore the contractor’s competent person should provide specific recommendations for excavation in accordance with OSHA requirements. Comment 15: Please provide a complete summary list of the geotechnical observation and testing services that should be performed as part of the construction of this proposed development. Response 15: Geocon should provide geotechnical testing and observation services during the grading operations, foundation construction, utility installation, retaining wall backfill and pavement installation. Table 1 presents the typical geotechnical observations we would expect for the proposed improvements. TABLE 1 EXPECTED GEOTECHNICAL TESTING AND OBSERVATION SERVICES Construction Phase Observations Expected Time Frame Ground Modification Ground Modification Installation Full Time Confirmation Testing Part Time to Full Time Grading Base of Removal Part Time During Removals Geologic Logging Part Time to Full Time Fill Placement and Soil Compaction Full Time Soldier Piles Solder Pile Drilling Depth Part Time Tieback Anchors Tieback Drilling and Installation Full Time Tieback Testing Full Time Soil Nail Walls Soil Nail Drilling and Installation Full Time Soil Nail Testing Full Time Foundations Foundation Excavation Observations Full Time Drilling Operations for Piles Part Time Geocon Project No. T2754-22-04 - 6 - REVISED November 21, 2022 Utility Backfill Fill Placement and Soil Compaction Part Time to Full Time Retaining Wall Backfill Fill Placement and Soil Compaction Part Time to Full Time Subgrade for Sidewalks, Curb/Gutter and Pavement Soil Compaction Part Time Pavement Construction Base Placement and Compaction Part Time Asphalt Concrete Placement and Compaction Full Time LIMITATIONS The recommendations of this report pertain only to the subject site and are based upon the assumption that the soil conditions do not deviate from those disclosed in this and Geocon’s 2021 report. If any variations or undesirable conditions are encountered during construction, or if the proposed construction will differ from that expected herein, Geocon West, Inc. should be notified so that supplemental recommendations can be given. The evaluation or identification of the potential presence of hazardous materials was not part of the scope of services provided by Geocon West, Inc. This report is issued with the understanding that it is the responsibility of the owner, or of their representative, to ensure that the information and recommendations contained herein are brought to the attention of the architect and engineer for the project and incorporated into the plans, and the necessary steps are taken to see that the contractor and subcontractors carry out such recommendations in the field. The findings of this report are valid as of the date of this report. However, changes in the conditions of a property can occur with the passage of time, whether they are due to natural processes or the works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and should not be relied upon after a period of three years. The firm that performed the geotechnical investigation for the project should be retained to provide testing and observation services during construction to provide continuity of geotechnical interpretation and to check that the recommendations presented for geotechnical aspects of site development are incorporated during site grading, construction of improvements, and excavation of foundations. If another geotechnical firm is selected to perform the testing and observation services during construction operations, that firm should prepare a letter indicating their intent to assume the responsibilities of project Geotechnical Engineer of Record. A copy of the letter should be provided to the regulatory agency for their records. In addition, that firm should provide revised recommendations concerning the geotechnical aspects of the proposed development, or a written acknowledgement of their concurrence with the recommendations presented in our report. They should also perform additional analyses deemed necessary to assume the role of Geotechnical Engineer of Record. Geocon Project No. T2754-22-04 - 7 - REVISED November 21, 2022 If you have any questions regarding this report, or if we may be of further service, please contact the undersigned at your convenience. Very truly yours, GEOCON WEST, INC. Lisa A. Battiato CEG 2316 Joseph J. Vettel GE 2401 Attachments: Geotechnical Report Review dated September 28, 2022 Figures 1 through 19, Geologic Map Distribution: (pdf) Addressee (pdf) Mr. Keith Hansen, O’Day Consultants GEOTECHNICAL REPORT REVIEW __________________________________________________________ DATE: September 28, 2022 TO: City of Carlsbad Land Development Engineering 1635 Faraday Avenue Carlsbad, CA 92008 Attention: Emad Elias PROJECT ID: SUP2022-0001 GRADING PERMIT NO.: GR2022-0038 SUBJECT: Omni La Costa Golf Course (1st review) Items Submitted by Applicant Items Being Returned to Applicant  “Limited Geotechnical Investigation, Champions Course Renovations, Omni La Costa Resort & Spa, 2100 Costa del Mar Road, Carlsbad, California,” by Geocon West, Inc., dated April 15, 2021.  Written report review comments. Based on our review of the submitted geotechnical report, we are providing the following comments that should be addressed prior to the next submittal. Please provide complete and thorough written responses to all comments. GEOTECHNICAL COMMENTS: 1. Please review the most current grading plan for the project and provide any additional geotechnical recommendations or modifications to the geotechnical report as necessary. 2. Please provide a statement addressing the potential impact of the project on adjacent properties from a geotechnical standpoint. 3. Please provide an updated “Boring Location Map” map utilizing a reduced version of the grading plan for the project as the base map but at a sufficiently large scale to clearly show (at a minimum): a) the existing limits of the golf course, individual fairways, drainages and water hazards, etc., and b) the locations of subsurface exploration. Please note that the “Boring Location Map” presented in the submitted report consists of a Google aerial photograph of the site that is on an 8.5x11” sheet and is at a significantly small scale (approximately 1” = 1230’) that results in difficulty showing the actual locations of the GR2022-0038 September 28, 2022 Page 2 of 2 subsurface exploration with respect to the course. Please produce the map at a scale that is sufficiently large to clearly distinguish the fairways and other features of the golf course and show the specific locations of the borings on the golf course; a sheet larger than 8.5x11” will likely be necessary to increase legibility and show all information. 4. Please clarify the range in depth of the existing unsuitable fill and young alluvium for the areas of the proposed cart paths, bridges, and retaining wall. 5. As the site is described as underlain by young alluvium and there is no consolidation testing reported, please provide the basis for the values of potential settlement (total and differential) for new structures and improvements that are provided in the report. 6. The report indicates liquefaction may be a design consideration for the proposed bridges and retaining wall associated with the project. Please further address and clarify the potential for liquefaction relative to the proposed project and provide recommendations to mitigate as necessary. 7. Please clarify the foundation recommendations for the supports for the proposed bridges. 8. Please provide the horizontal setback distance from adjacent slopes for foundations associated with the proposed bridges and the retaining wall. 9. Please address if a creep load should be applied to the foundations for the proposed bridges located adjacent to sloping ground; provide the lateral creep load as necessary. 10. Please provide any recommendations to address the relative shallow groundwater with respect to the foundations for the proposed bridges or retaining wall as necessary. 11. Please clarify if reinforcing is recommended for all hardscape improvements due to the expansive soils and underlying young alluvium. 12. As the results of Expansion Index testing presented in the report indicate a medium expansion potential (EI=74 to 78), please provide recommendations as necessary and a statement that the proposed foundation system/slabs on-grade will meet the requirements of Section 1808.6 of the 2019 California Building Code. As soils with expansion index (EI) over 20 are considered expansive and require mitigation in accordance with Sections 1803.5.3 and 1808.6 of the 2019 CBC, please indicate the method of Section 1808.6 (1808.6.1 through 1808.6.4) that is being recommended to satisfy the requirement, and provide the Effective Plasticity Index and any other parameters for foundation design in accordance with WRI/CRSI Design of Slab-on-Ground floors as necessary. 13. Soluble sulfate testing presented in the report indicates both moderate and severs sulfate exposure (S1 and S2). Consequently, please provide recommendations for sulfate resistant concrete (compressive strength, w/c ratio, type cement) consistent with the 2019 California Building Code and ACI 318, Tables 4.2.1 and 4.3.1 assuming a “Severe” (S2) exposure class. 14. Please provide the OSHA Type Soil (A, B, or C) and associated temporary slope inclination (H:V) that the construction plans and contractors should adhere to during the design and construction of the development. 15. Please provide a complete summery list of the geotechnical observation/testing services that should be performed as part of the construction of this proposed development. PROJECT NO. T754-22-04 FIG. 1 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) :I ~, ! ~ [[ o· 10· 40' 5 20 SCALE: 1" = 40' ,..... BO' _,,/' Dense ~ration / Gro'!fl<' Obscured //1/- 123.l 0 / ,/, / / / ./ / / LOT 4 / MAP 1454_3 0 ~ J ) )'~ ' -110 Dense Vegetation J'-Ground Obsc,p!(f I 11s9 1111 ~ , 115.8 } GEOCON W E S T , I N C . LOT 27 MAP 14543 '18 11.?.6 GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 \ D EB D E9 D D _I_ PROJECT NO. T754-22-04 FIG. 2 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. B-7 ½ -5’ Qya (SM) 0 -½’ afu Qya ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) :\ :, ! ~ [ o· 10· 40' 5 20 80' SCALE: 1" : 40' -f80- 184 \ _./ -~ ~nse Vegetation <fround Obscured 1/66 7 1416 ----------------- ~-;!i; \ I I , ,,, ~~u ,,..,---~ I 1398 / / r I I 1141 f LDT 28 ,sr ,,_,rfa'"( ,,x,• ,' / /3L / I < l:.i,4 MAP 14984 7 - I r ~~~\' : , )\\ \ ~' \ \ \ :,, :~~~,..,.,,,.u; . / 1,,r ! 1 I I i ~ o\ P 12 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 D EB D E9 D D _I_ PROJECT NO. T754-22-04 FIG. 3 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. B-5 1-5’ Qya (SM) 0 -1 afu Qya ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) /UfSCUreG / \ LDT 28 MAP 14984 1056 ", /i ~( I I I .., I I I I "'1 I I I I .... : Dense Vegetation , Ground Obswred ~ I I \ \ ... , ~---( .. __ ~\ 994 -✓ '~ l 9TH TE I I //'/ I I ~i ~~s CART PATH, REPLACE \/ITH NEIi . I PATH ON-GRADE / "'{°" Dense Vegetat11/1i~ Ground ObSC/J/11:1 I I LOT 28 MAP 14543 _! GEOCON W E S T , I N C . I f I I I I 1! {"R:" I I I I I I / / I /j I I/ _I I V l I / 105 110- 115 720 4.J J I [1213~ffo-11 I I I I I I LOT 88 MAP 14803 \ I \ Dense Vegetation Ground Obswred I MAP 14803 o· 10· 40• 5 20 SCALE: 1" = 40' GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 D EB D E9 D D _I_ BO' PROJECT NO. T754-22-04 FIG. 4 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. B-3 ½ -5’ Qya (SM) 0 -½’ afu Qya ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) I ! r o· 10· 40• 5 ~~ALE: 1" = 4ff w \ I • ) LDT 28 t, 124.1 .O AP 14984-'------I D EB ~5 I I ~17 ) i i /~ I I I I I C t I ~ I l I GEoc,q~ MATE IALS w E s T , AL ENVIRONME'::'.T~!:LIFORNIA 92562 GEOTECHNICPLACE #101, MURRIET , 41571 CORNING D EB D E9 D D _I_ PROJECT NO. T754-22-04 FIG. 5 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) I\ 1) I I I I 1~1, ii} :I --r"'-~=Ll=,:IL:-:1=-=-11-e;,,=, .. ,,_,,.,_.,,_"it--, oui _J G.B. b~~ .. □ :s.? Dense Veg GroundQ 'V/ 0 NEIi CART FS=105.2,~ ,--;'/ EXISTIN~ Den.le Veg~· . ' CAR1/ATH /Ground Cfl!scured ) ,i I !I, j ----m, I ,,/ ' ,'r I ,i.. /:/ --~ 91,1 /"\... 103.3 \ I J 94.1 984 r \ (!198 (· \ I ·) / 'll4 I \ \ , ... I ' \ ~Tj,zTEE I \ I .... __ , ) r 966 LDT 28 MAP 14984 r ---------- ( J 137 ~ S££ SHEET !J T __ j_...---\\ I 9."5 \\.4.-, • I I I I I l"-1 I I 909 93 INUNDATION LIMITS <EXISTING L PROPOSED> ;~,. I I I .,., \., ... I I -,--_,< ,----- / /' / , .... --_!.:_.---__ _ _Q(Jl ll I I I I Dense Vegetation Ground Obscured !NUNDA TION LIMITS (EXISTING L PROPOSED> LOT 28 MAP 14543 Dense Vegetahon Ground Obscured Dense Vegetation Ground Obscured GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 1 i o' 10' 40' D EB D E9 D D _I_ 5 20 BO' SCALE, 1 • = 40' PROJECT NO. T754-22-04 FIG. 6 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) LO\ 44 MAP 14543 # I I) r r;1 II~ ;: "' :;.t :'; ~ \ \ \ I I LDT 28 MAP 14984 "" \/ \ / ✓ I . 18.J \ \ 864 \ \ I \ \ I \ I I I l,/ ---l ,.,,, I ' \ "" r' I \ I \ .., ,r .)\ - ' I 88.6 .)\ ,,,.,/ ' / '/ d2.8 ,,, I _I /'< / / _.,, ,/ / / ,,.,,. _ ____..,i: __ J t./ ~ . \;- _/ _/ ----,!!~,H<r.e-...Y / . ,,· T/.5 I \ S££ SH££T 10 89,:, 895 ';,\\ "" I I I I --: I I I I .., I I I I --{ I I I I -,; I I I I -,.J, I I I I -.a I I so,, --1 L--"' ,./ I I GEOCON W E S T , I N C. \ --1 -.,.~\-;se Veg~ BSD Ground Obscu I • I I I GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 I I I I 1 i 0' 10' 40' D EB D E9 D D _I_ 5 20 60' SCALE: 1 • = 40' PROJECT NO. T754-22-04 FIG. 7 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) 762 I /, \ I 84.1 I ( \ I I I · 766 \ . I 9' I I I "·~ ::-----.. ✓ ).-___ {_ __ _ ,,,,. -., I • 4, )·----, .., -", I I ' .., ' / I j' /I LDT 28 / MAP 14984 9 'AB ,,'¾--:#- / '-...;> I ' 'Y' \ ..........._. ~-~'-~ ---... -..__ -...::::~--------..(' -.........:~ '---------- '-____:::,,, SEE SHEET 11 I . I ..i...:...._ ....:::=:---'\ LOT 28 MAP 14,5 1 J V / ( LOT 6)ii·/ MAP )-4805 ,-,( I / APN 213-201-06 I I I L I' ◊◊ ( 0 \,'-~ 982 r f'-r o· 10· 5 20 J 40' SCALE: 1• = 40' GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 D EB D E9 D D _I_ BO' PROJECT NO. T754-22-04 FIG. 8 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. B-6 1 -5’ Qya (SM) 0 –1’ afu Qya ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) "' "' ~ I "' ;;; z a. « _) J J J 1~ LOT 2 MAP 15719 I I " I ~~ <')" CV I'> N CV ...J II -...1 r1 gg ~g & " 0\ °' ,. ... .,;,, .... "'"' ........ .:s., LOT MAP 1 ' ',~/ '; ----.J l I ,,,-'--I --: I I I FS=88 1 ~ / 1 93 TING '--..,.._ }-... ..,: __ ' PATH \ \ "---T '--- ~ BUNKER 'Jf"....._:_ '7. ...,.,, ...... --... (\ ' \ /I 1'"' ,-....._, \ / I \/ I r- ~1>...,--.0'; : \ fi8,8 ""'--1 ----i_ ""'~/4.. __ j_ --,~ ,,,'-,-----f--- 41ii _, .. 69< -.., I cr UNK 708 l.,.j llJ ' I I I I ' 693 70.S fY I \ LDT 28 MAP 14984 611 7{J ----: I "\ ~\ I I , ---, _\_ S££ SH££T 12 /, / . I \ I ,,,__./ oltt, 1/ "-.......7_. ,t ---- I '-. .. '--t . • --zg ( BUNKER \ ,s,, .. ~ ... >J , LDT 28 MAP 14984 ,· ,. ---/ IAL -I ,,,, GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 o· 10· 40' D EB D E9 D D _I_ 5 20 60' SCALE: 1' = 40' PROJECT NO. T754-22-04 FIG. 9 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) /. 9 * i:s '< ~ ~ "( .__, ~ ~ t 8 ' / I I I I I I I , 1,' I/ I I 6 ,---, I I • f 4TH TEEJ I I \ I , __ ., LDT 28 MAP 14984 , , : I I .., \ ~· I I ..,, I I I 1 "'1 I I I I .,; 66] 6 , I I ~ 12TH GREEN ,,:/ , ,,,_ 7 l-,C' "'"' , .. .-~ Im '"{I I ., -I Wi Zj Oj N !<Ji., / ~i; -~--f-✓ fat& --· 0 ~ I 0 I ;'.? (\J -::: "'~ / I I I I <t: 2 . w LL ill ' I I ornse k¢~ 'imund Ob '~" /I ,, _, LOT 30 MAP 14543 LDT 28 MAP 14984 I I I I ,' I GEOCON W E S T , I N C . \ 0 ' . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 i O' 10' 40' D EB D E9 D D _I_ 5 20 BO' SCALE: 1" = 40' PROJECT NO. T754-22-04 FIG. 10 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) r g-; l L0~8 I '< AP 1 543 ~ 8.'5 :::s "" -..J !;;:! ·1 ~ CV'° "'"' tl "'"' ·~ ~~ ~~ 5;l 8'" ~fil1se Gr und ., 85A ~ APN 215-110-5 / ,.... / APN 215-110-60 ) <..., :_o/u,.c APN 215~61 I I I I I I I I I I APN 215-110-~7 I I / LOT 30 MAP 14543 LDT 28 MAP 14984 I I I APN 215-22~ APN 215-220-05 724 APN 215-220-58 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 i o' 10· 40' D EB D E9 D D _I_ 5 20 BO' SCALE: 1. = 40' PROJECT NO. T754-22-04 FIG. 11 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 ……GROUNDWATER ENCOUNTERED 3.5’ Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 B-7 1½ -5’ Qya (CL) 0 -1½’ afu Qya ……. GEOCON BORING LOCATION (2002) 3.5’ .....__ I I \' \"\ \ \ \ J I \/1:\ LDT 1 -•~t~~ ~MAP 14984 \ \ I -'--;,;~~--_-:-,.~:_-_-~-"'"'>~'°-:::="'.:::.c::;_..,!':,1/,. ; .::;-,- \ ~ <-- Dense Vegetation Ground Obscured \ \ \ \ AP 15-220-58 / * 7l2 ·, ,{+ ., "'✓ ~ ~Q '6" " ~~J.:, ' ~ sos ' 57.1 I I I I \ /,:1 I~- I I J I I / / / I I I ' I ,1 / I I.~--14 TEE ,/ (I I i / I I I ?'6' ,' I 4"l I I__ I S££ SH££T 15 ) \ \ \ I. I I I I ;4111 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 i O' 10' 40' D EB D E9 D D _I__ 5 20 BO' SCALE, I" = 40' PROJECT NO. T754-22-04 FIG. 12 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 B-7 2 ½ -16 ½ ’ Qya (SC & CL) 0 –2 ½’ afu Qya ……. GEOCON BORING LOCATION (2002) 8’ B-6 2 -16 ½ ’ Qya (CL) 0 –2 afu Qya3.5’ APN I 216-600-05 \ OJ f ~igfo ' iR :R "'\'' ~~, -_ ffi " d u12· PVC SM/ 6 I _/ __ , __ 421 _y_ 41 D E9 ---..,_ _!_ ,--=----..,_ ---..,_ ---..,_ ---..,_ ---..,_ D LDT 1 MAP 14984 ---..,_ ---..,_ ---..,_ ---..,_ ---..,_ -----: APN 215-220-22 GEOCON W E S T , I N C . GEOTECHNICAL ENVIRONME 41571 CORNING PLACE #101, MURRIET'::'.~~!:L.1~'i~l~R~~~; i o· JO' 40' 5 20 SCALE: I• = 40' D EB D E9 D D _I_ 80' PROJECT NO. T754-22-04 FIG. 13 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002)\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ APN 216-600-01 \ \ / \'&. \ \ l.- APN I' 216-600-o4 (:j ~ I ,J--..._ ' APr 216-600-03 I I I I I I EX 12" { PICSHI? I '-, _ __,, I~ ---,, '"'<: ', \/"' TEE 1;:lfi .. ~ I ,/~ ~ LOT 1 h y---'Tt'ft~~till.A.JJ'n"MAP 14984;:: ?' /, _/ :/ CART PATH REPLACE AT GRADE ~I [ J A / -.I' A,, ) __, I I/ L , I I GEOTECHN, I N C . 41571 CORNIN~~ALC, ENVIRONME E #101 NTAL , MURRIETA, CAL.l~ATERIALS ORNIA 92562 0' 10' 40' D EB D E9 D D _I_ 5 20 SCALE: 1 • = 40, 80' PROJECT NO. T754-22-04 FIG. 14 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 B-4 0 –16 ½ ’ Qya (CL) Qya ……. GEOCON BORING LOCATION (2002) 3.5’ \ / \ ) f I / 0 LIMITS (EXISTING L PR□P□SED> I I i • . <t: I • I -.w 'z 10 iN I i <t: -~ ,w I Li_ I I I I 1 ,, j I I I \ \ \ I \ /\ \ LDT 1 MAP 14984 .,,..---. . ;:. . ''{_ I ··-: = I ..,, \ \ \ - /: ,~ 1· \ ~ /1, '1 ,.: 1 I / / \ I , I -~' I I I I :._ I I • / I /.. I : ' ,I ~ .( I I', ..... I I \.-1 I I I ,"- I I I [ MAP 6941 APN 215-231-12 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 i O' 10' 40' D EB D E9 D D _I_ 5 20 80' SCALE, 1" = 40' PROJECT NO. T754-22-04 FIG. 15 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 B-7 0 –16 ½ ’ Qya (SM & CL) Qya ……. GEOCON BORING LOCATION (2002) 4’ 1-19 ½ ’ Qya (CL) 0 -1 afu Qya B-1 7.2’ '92,---- / ~ : I ; : I ,' 1ST TEE I ,' ;' _,,, .,f 1 \, It ' I \ \. ---t"\I ~(:~,, o, -~:!.., .... _ 19.3 ~, '---i Y1 ~~~ ... ----'----'"''~I"~ \ ~ 17.6 o'-',,,z'. ' ' \ LOT 1 MAP 14984 I\ I \ I I ' \ \,- \ \ \ 11 \ \ \ \ \ \ \ 16.S \ \ '. I \ \ \ \ \ 15.6 \ \ \ \ \ \ \ \ \ \ \ BUNK _____ j_ ___ --:ji~_f.__ __ \ \ \ ,\ \ Dense 'Vegetat.t· · 1 Groui Obscu GEOCON W E S T , I N C . 244 ~I NKER ~ . , h ~ I ' I 17 TEE \ :. -~---=-~~.;f GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 D EB D E9 D D _I_ PROJECT NO. T754-22-04 FIG. 16 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) l ! ~ ~ '10' 40' 20 80' '~LE: ,· = 40' u ___ .,. -- 21.5 ,-, ' '· ' ..... , ,... 10 -~---- ,...--(.. \ ,,.,,. _,,.,, l I ~6 \ \ 26.2 16.4 116 _,....,,, ..... __, C 25.6 25.3 ---L ____ t__ .. - -~t s--=17.5 - --~ ----_ -/- 17.8 _.. .. ,----,--, ,;r \ \ I }-. • I I I ,,:, C / I ,t.. I ~ ---·f ..... <?s .......... I I I ------t -~-==t :,,' --~-/ ~ -\- I ... I I I I //' 25.1 29.4 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 D EB D E9 D D _I_ PROJECT NO. T754-22-04 FIG. 17 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) ----~<, \ \k I I I I 16.5 I-- ,,.,,.,,.✓--- FS=,; 2 -----r----,-· . r·----18 TEE ----- I I 164 I I I I I \ \ \ '\,, '~,,. ' '<' \ \ -,.-----,.----~\ ------r t,; 7.oNf- 86 -') z.. 16.S 16.3 157 17.4 17.S 116 17.6 ---·- ! ! ~ o· 10· 40' 5 20 80' SCALE: ,· = 40' ~N ee·oe•40• ~-N ee•o9•o4,~ 243.36'> ~-~-~~32' ~-----..__ ..__ ..__ ..__ G , I N c EOTECH . 41571 CORNl~~~;C~~~lRONMENTAL M • MURRIETA, CALIFO A RIALS RNIA 92562 D EB D E9 ..__ D ..__ D _I_ PROJECT NO. T754-22-04 FIG. 18 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 B-2 1 ½ –16 ½ ’ Qya (SM & CL) Qya ……. GEOCON BORING LOCATION (2002) 4’ 1-19 ½ ’ Qya 0 -1 afu Qya B-2 8’ 0 –1 ½’ afu APN 216-590-01 22.8 i i . I I 125 / 0/ /. / / / / / / / ..,_,,t_ L-. --~ -- 1().4 122 D E9 kJ 14.3 1/u \ ----1 \, r '\ I \I '\ D E9 D E9 --!-I ~.________,__ _ __. D ,.......<~..wi.... .......... ...._ 1/S 1/J 11.6 112 1_?.J 124 114 t lm1' MAP 1498 ----------13.1 Id 1?.6 .; 158 154 116 18.J 16.6 16.J \ ·'\" \ \ I \ ·"1 r--1 ( .. I D __I_ U2 142 Q.3 GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 o· 10· 40• s 20 so· SCALE, 1" = 40' PROJECT NO. T754-22-04 FIG. 19 CHAMPIONS COURSE RENOVATIONSOMNI LA COSTA RESORT & SPA 2100 COSTA DEL MAR ROAD CARLSBAD, CALIFORNIA GEOLOGIC MAP HD OCTOBER 2022 Source: O’Day Consultants, Rough Grading Plan for Omni Resort Golf Course, prepared September 1, 2022. ……GROUNDWATER ENCOUNTERED 3.5’ GEOCON LEGEND Locations are approximate B-6 ……. GEOCON BORING LOCATION (2021) Qya .…. YOUNG ALLUVIAL DEPOSITS afu …...UNDOCUMENTED FILL B-8 ……. GEOCON BORING LOCATION (2002) \ -15- \ -\ \ \ --\ \ \ JlS \ 114 \ \. \ \ \ 175 ........_ <7 \ \ \ 12.:, \ / / \ \ \ \ \ / I \ \ .,.,. .-,·~·~ .-.,.,. _,,.· _.,.,. _.,.,. / / / / / / ,,- / I I / 116 14~ 18.4 ..- \ ~'r! \" \ y \ 1 --""' _,\;,,""---/ ,;:-,.,~t k _..,.-, / / I I I ·/ ~ l \ (✓~_,.. [......-,...,,,.--- ll6 / / / ,.-- / ,, / / 15.5 161 / / ,, 13.3 22 ,, _/ / / 192 / Dense Vegetation Ground Obscured /1 48 ..,,,,- / ----// L / ( 16.2 14.5 / ____,... / 169 U.5 ) 14.6 ) / 761 17~ 11., '-. -----' ' GEOCON W E S T , I N C . GEOTECHNICAL, ENVIRONMENTAL, MATERIALS 41571 CORNING PLACE #101, MURRIETA, CALIFORNIA 92562 -1 \ ~ o· 10' 40' 5 20 SCALE, 1• • 40' D EB D E9 D D _I_ 80'