Loading...
HomeMy WebLinkAboutCT 00-16; Poinsettia Properties Deck/Patio Cover Exhibit; Tentative Map Exhibit.., I(. • BALCONY /DECK DESIGN GUIDELINES THE FOLLOWING ARE DESIGN GUIDEUNES/STANDARDS FOR BALCONIES AND DECKS WITHIN PLANNING AREAS 2 AND 4 OF THE POINSEmA PROPERTIES SPEC/RC PLAN. THE PURPOSE OF THE DESIGN GUIDELINES IS TO PERMIT 7HE CONSTRUCTION OF BALCONIES/DECKS 7HA T ARE AES7HETICALL Y PLEASING AND UNOBTRUSIVE. 7HE DESIGN GUIDELINES ARE ACCOMPANIED BY A BALCONY/DECK EXHIBIT THAT IDENTIFIES WHICH UNITS MAY HA VE BALCONIES/DECKS ANO THE LOCATION OF THE BALCONY/DECK ON A UNIT-BY-UNIT BASIS. BASIC REQUIREMENTS 1. ALL BALCONIES/DECKS SHALL COMPLY WITH THE REQUIF/EMENTS OF THE UNIFORM BUILDING CODE. 2. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR A BALCONY /DECK, PROOF MUST BE SHOWN THAT THE BALCONY /DECK HAS BEEN APPROVED BY THE HOMEOWNERS ASSOC/A TION. APPROVAL BY THE HOA IS DISCRETIONARY AS OUTLINED IN THE CC&RS (HOA LETTER OR HOA STAMP ON PLANS). J. A BALCONY /DECK MUST 8£ OF COLOR AND DESIGN THAT IS COMPATIBLE WITH THE DWELLING UNIT. 4. A BALCONY /DECK MUST MAINTAIN All Sf7BACK REQUIREMENTS AS SPEC/RED IN THE PO/NSEmA PROPERTIES SPECIFIC PLAN, THE PLANNED DEVELOPMENT ORDINANCE, OR THE BALCONY/DECK DESIGN GUIDELINES, WHICHEVER IS MOST RESTRICTIVE. 5. NO BALCONY/DECK MAY INTRUDE INTO ANY YARD SO AS NOT TO COMPLY WITH SECTION 21.46.120 OF THE CITY ZONING ORDINANCE. 6. THIRD-LEVEL BALCONIES/DECKS ARf NOT PERMITTED. 7. BALCONIES/DECKS ARE PERMITTED ONLY ON THE UNITS SPECIF/CALLY /DENT/RED AS ALLOWING FOR BALCONIES/DECKS PER THE BALCONY/ DECK EXHIBIT. SPEC/RC DEVELOPMENT STANDARDS 1. SECOND-STORY BALCONIES/DECKS SHALL BE A MAXIMUM OF 10 FEET DEEP ANO 20 FEET WIDE, AND MAINTAIN A MINIMUM 5-FOOT SETBACK Fl?OM FENCES, SOUND WALLS, OR COMMUNITY WALLS. 2. THE OUTSIDE EDGE OF A BALCONY /DECK MUST MAINTAIN A MINIMUM DISTANCE OF 10 FEET FROM ANY ADJOINING DWELLING UNIT OR OTHER BALCONY /DECK POST. J. THE LOCATION OF BALCONIES/DECKS MAY BE MOD/RED FROI.I THE COVERAGE AREA SPEC/RCALLY /DENT/RED BY THE BALCONY/DECK EXHIBIT, SUBJECT TO THE APPROVAL OF THE HOMEOWNERS ASSOC/A TION ANO THE CITY OF CARLSBAD PLANNING DEPARTMENT. TRELLIS/PA TIO COVER DESIGN GU/OEUNES THE FOLLOW/NC ARE DESIGN GUIDELINESjSTANDARDS FOR TRELLIS/PA TIO COVERS WITI-IIN PLANNING AREAS 2 AND 4 OF THE POINSEmA PROPERTIES SPECIFIC PLAN. TIIE PURPOSE OF THE DESIGN GUIDELINES IS TO PERMIT THE CONSTRUCT/ON OF TRELLIS/PA TIO COVERS THAT ARE AESTI-IETICALL Y PLEASING AND UNOBTRUSIVE. THE DESIGN GUIDELINES ARE ACCOMPANIED BY A TRELLIS/PA TIO COVER EXHIBIT THAT IDENTIFIES WHICH UNITS MAY HA VE TRELLIS/PA TIO COVERS AND THE LOCATION OF 7HE TRELLIS/PA TIO COVER ON A UNIT BY UNIT BASIS. BASIC REQUIREMfNTS 1. ALL TRELLIS/PATIO COW::RS SHALL COMPLY WITII Tl/£ REQUIREMENTS OF THE BUILDING UNIFORM CODE. 2. PRIOR TO THE ISSUANCE OF BUILDING PERMIT FOR A TRELLIS/PA TIO COVER, PROOF MUST BE SHOWN THAT THE TRELLIS/PA TIO COVER HAS BEEN APPROVED BY THE HOI.IEOWNERS ASSOC/A TION. APPROVAL BY Tl-/£ HOMEOWNERS ASSOC/A TION IS DISCRETIONARY AS OUTLINED IN THE CC&RS (HOA LETTER OR HOA STAMP ON PLANS). J. A TRElLIS/PATIO COVER MUST BE OF COLOR AND DESIGN TI-IAT IS COMPATIBLE WITII Tl/£ DWELLING UNIT. 4. A TRELLIS/PA TIO COVER MUST MAINTAIN ALL SEITJACK REQUIREMENTS AS SPECIFIED IN Tl-IE POINSETTIA PROPERTIES SPECIFIC PLAN, THE PLANNED DEVELOPMENT ORDINANCE, OR Tl-IE TRELLIS/PA TIO COVER DESIGN GUIDELINES, WHICHEW::R IS MOST RESTRICTIVE. 5. NO TRELLIS/PA TIO COVER MAY INTRUDE INTO ANY YARD SO AS NOT TO COMPLY ltlTII SECTION 21.46.120 OF THE CITY ZONING ORDINANCE. 6. TRELLIS/PATIO COVERS ARE PERMITTED ONLY ON THE UNITS SPEC/RCALLY !DENT/RED AS ALLOWING FOR TRELLIS/PA TIO COVERS PER THE TRELLIS/PA TIO COVER EXHIBIT. 7. DETACHED PA TIO COVERS MAY BE ALLOllrn OUTSIDE OF THE COVERAGE AREA SPECIF/CALLY IDENTIFIED BY THE BALCONY & PA TIO COVER EXHIBIT, PROVIDED Tl-IE DETACHED PATIO COVER DOES NOT fNCROACH INTO THE USABLE 15 FOOT BY 15 FOOT REAR YARD AREA AND PROVIDED ALL SETBACKS ARE MAINTAINED, SUBJECT TO Tl-IE APPROVALS OF THE HOMEOWNERS ASSOC/A TION AND THE CITY OF CARLSBAD PLANNING DEPARTMENT. 8. ALL LOTS MUST MAINTAIN A USABLE 15-FOOT BY 15 FOOT REAR YARD AREA. ONLY OPEN-ROOF TRELLIS OR OPEN-ROOF PATIO COVERS (E.G., LATTICE PANELS OR MA7rn/ALS ARRANGED PARALLEL TO EACH OTHER AS 2• X 2• WOOD WITH SPACES BETWEEN EACH PIECE) MAY EXTEND INTO Tl-IE REQUIRED 15-FOOT BY 15 FOOT REAR YARD AREA. SPECIFIC DEVELOPMENT STANDARDS 1. ALL TRELLIS/PA TIO COVERS SHALL HA VE A MAXIMUM DEPTH OF NO MORE THAN 20 FEET ANO MUST MAINTAIN A MINIMUM 5-FOOT SETBACK FROM RfAR ANO SIDE YARD FENCES, SOUND WALLS, OR COMMUNITY WALLS. 2. TIIE OUTSIDE EDGE OF A TRELLIS/PA TIO COVER MUST MAINTAIN A MINIMUM DISTANCE OF 10 FEET FROM ANY ADJOINING DWELLING UNIT OR OTI-IER TRELLIS/PA TIO COVER POST. A MAXIMUM OF 2 FEET OVERHAND IS ALLOWED PAST Tl-IE POST. J. THE LOCATION OF TRELLIS/PATIO COVERS MAY BE MODIFIED FROM THE COVERAGE AREA SPECIRCALLY IDENTIFIED BY Tl-IE TRELLIS/PA TIO COVER EXHIBIT, SUBJECT TO THE APPROVAL OF THE HOMEOWNERS ASSOC/A TION AND THE CITY OF CARLSBAD PLANNING DEPARTMENT. [@ LOT NUMBER FLOORPLAN TYPE ----- @ I I Q i ............... SHORELINE DRIVE i7AR] MAXIMUM LIMITS OF OPTIONAL ANO PROPOSED DE:Cl<S -- PR.omcrDF.SKJNCoNsvLrANTS PLQiNINO • PJrrAIIWPDEm&♦ BNDI Cl• IUWVBYJUI 1111 B --BOO, Sm Dloeo, CA 92101 MAXIMUM LIMITS OF PAT/OS COVERS (DEPTII NO MORE TIIAN20? (SEE NOTE RE: 15'x15' USABLE AREA REQUIRED) ,19-23'"6471 FAX ,19-234-0349 I I ! AVENfoA ENCINAS ---- ® [El @ ~ - ® i3ARI -- ---- WA7E'RS END DRIVE @ iJCRI SKeiiWATER STREET ® [El 0204060 GRAPHICAL SCALE @ iJCRI ----- ---- SEA HOUSE II I ---- rtt--...J...J@) [2~ @) i2BRI ® iJCRI @ I ~ "C i I ® ~ - @ iJCRI I I - I I /\ I \ \ \ DECK & PA TIO COVER EXHIBIT POINSETTIA PROPERTIES CITY OF CARLSBAD, CALIFORNIA I I ® iJCRI I I I I I I I I I I I I ~ I I I I I I I I I I I ! I I I' I I 11 /I I I /I I ,1 II I I /I I I / / I I I I II / t/ I I/ I I I I I SHEET 1 OF 2 I I "' It Q 'X .., 0 Ill \, t I,. { " Iii })..i-~ ~l-~~ NI V :t I(\ )< \J ~ ' ~"" ' ~ 'l I I,. • l..''1 <l () ., II:: ~ Iii II) t ~ \-. ~\\.. \I~ ~ ?-~~ BALCONY /DECK DESIGN GUIDELINES THE FOLLOltlNG ARE DESIGN GUIDELINES/STANDARDS FOR BALCONl£S AND 0£CKS ltlTHIN PLANNING AR£AS 2 AND 4 OF TH£ PO/NSEmA PROP£RTIES SPECIFIC PLAN. TH£ PURPOSE OF TH£ DESIGN GU/0£LINES IS TO P£RMIT TH£ CONSTl?UCTION OF BALCONIES/DECKS THAT AR£ AESTHETICALLY PLEASING ANO UNOBTRUS/\1£ TH£ D£SIGN GUID£LINES ARE ACCOMPANIED BY A BALCONY/DECK £XHIBIT THAT ID£NTIF/£S WHICH UNITS MAY HA V£ BALCONIES/DECKS AND THE LOCATION OF THE BALCONY/D£CK ON A UNIT-BY-UNIT BASIS. BASIC REQUIREMENTS 1. ALL BALCONIES/DECKS SHALL COMPLY ltlTH TH£ REQUIREMENTS OF THE UNIFORM BUILDING COD£. 2. Pl?IOR TO TH£ ISSUANCE OF A BUILDING PERMIT FOR A BALCONY /DECK, PROOF MUST BE SHOWN THAT THE BALCONY /DECK HAS BEEN APPROVED BY THE HOMEOWNERS ASSOC/A TION. APPROVAL BY THE HOA IS DISCRETIONARY AS OUTLINE{) IN THE CC&RS (HOA LETTER OR HOA STAMP ON PLANS). J. A BALCONY /DECK MUST BE OF COLOR ANO {)£SIGN THAT IS COMPA TIB1£ ltlTH TH£ DWELLING UNIT. 4. A BALCONY /DECK MUST MAINTAIN ALL SE1EIACK REQUIR£MENTS AS SPECIFIED IN THE PO/NSE:TTIA PROPE:RTIES SPECIFIC PLAN, TH£ PLANNED D£\/ELOPMENT ORDINANCE, OR THE BALCONY/D£CK DESIGN GU/OELINES. WHICHEVER IS MOST RESTRICTIVE. 5. NO BALCONY/DECK MAY INTRUDE INTO ANY YARD SO AS NOT TO COMPLY ltlTH SECTION 21.46.120 OF THE CITY ZONING ORO/NANCE. 6. THIRD-LE:'.f:L BALCONl£S/D£CKS ARE NOT PE:RMITTED. 7. BALCON/ES/0£CKS ARE PERMITTED ONLY ON THE UNITS SP£CIFICAU Y ID£NTIFIED AS ALLOWING FOR BALCONIES/DECKS PER THE BALCONY/ DECK EXHIBIT. SPECIFIC OEVELOPMENT STANOARDS 1. SECOND-STORY BALCONIES/DECKS SHALL BE A MAXIMUM OF 10 FEET DEEP AND 20 F££T WIDE, AND MAINTAIN A MINIMUM 5-FOOT SETBACK FROM FENCES, SOUND WALLS. OR COMMUNITY WALLS. 2. THE OUTSIDE EDGE OF A BALCONY /DECK MUST MAINTAIN A MINIMUM DISTANCE OF 10 FEET FROM ANY ADJOINING DWELLING UNIT OR OTHER BALCONY/DECK POST. J. THE LOCATION OF BALCONIES/DECKS MAY BE MODIFIED FROI.I 7HE COVERAGE AREA SPECIF/CALLY IDENTIFIED BY THE BALCONY/DECK EXHIBIT, SUBJECT TO 7HE APPROVAL OF THE HOMEOWN£RS ASSOC/A TION AND THE CITY OF CARLSBAD PLANNING DEPARTMENT. TRaUS/PA TIO COVER DESIGN GUID£LINES TH£ FOLLO'MNG ARE DESIGN GUIDELINES/STANDARDS FOR m£LLIS/PA TIO COVERS WITHIN PLANNING AREAS 2 AND 4 OF THE PO/NSEmA PROPERTIES SPECIFIC PLAN. THE PURPOSE OF TH£ D£SIGN GUID£LINES IS TO PERMIT THE CONSTRUCTION OF TRELLIS/PA TIO COVERS '/HAT ARE AESTHETICALLY PLEASING AND UNOBTRUSIVE. TH£ 0£SIGN GUID£LIN£S ARE ACCOMPANIED BY A TRELLIS/PA TIO COVER EXHIBIT THAT IDEN11F/£S WHICH UNITS MAY HA V£ TRELLIS/PA 110 COV£RS AND THE LOCATION OF THE TR£LUS/PA 110 COV£R ON A UNIT BY UNIT BASIS, BASIC REQUIR£MENTS 1. AU TR£LLIS/PA110 COVERS SHALL COMPLY WITH TH£ R£QUIREMENTS OF TH£ BUILDING UNIFORM COD£. 2. PRIOR TO TH£ ISSUANCE OF BUILDING PERMIT FOR A TR£LUS/PA TIO COVER, PROOF MUST 8£ SHOWN THAT TH£ TR£LLIS/PA TIO COVER HAS BE£N APPROVED BY THE HOMEOWNERS ASSOC/A 110N, APPROVAL BY THE HOMEOWNERS ASSOC/A 110N IS DISCRETIONARY AS OUTLINED IN THE CC&RS (HOA L£TTER OR HOA STAMP ON PLANS). J, A TR£LLIS/PA710 COVER MUST BE OF COLOR ANO D£SIGN THAT IS COMPATIBLE W/'/H THE DW£LLING UNIT. 4, A TR£LLIS/PA 710 COVER MUST MAINTAIN ALL S£TBACK REQUIR£M£NTS AS SP£CIFIED IN THE PO/NS£mA PROP£R11£S SPECIFIC PLAN, THE PLANNED DEVELOPMENT ORDINANCE, OR THE TR£LLIS/PA 110 COVER DESIGN GUID£LIN£S, WHICH£VER IS MOST RESTRICTIVE. 5. NO TRELLIS/PA 110 COVER MAY INTRUDE INTO ANY YARD SO AS NOT TO COi.iPL Y WITH S£CTION 21.46.120 OF TH£ CITY ZONING ORO/NANCE. 6. TR£LLIS/PA 110 COVERS ARE P£RMITTED ONLY ON TH£ UNITS SP£C/FICAU Y ID£NTIF/£0 AS ALLOWING FOR TRELLIS/PA 110 COVERS P£R THE TR£LUS/PA 110 COVER EXHIBIT. 7. DETACHED PA 110 COVERS MAY BE ALLOW£0 OUTS/0£ OF THE COVERAGE AR£A SP£CIFICALLY IDENTIFIED BY THE BALCONY & PA 110 COVER £XHIBIT. PROVIDED TH£ 0£TACH£D PA 110 COV£R DOES NOT ENCROACH INTO TH£ USABLE 15 FOOT BY 15 FOOT REAR YARD AREA AND PROVIDED ALL SETBACKS ARE MAINTAINED, SUBJ£CT TO THE APPROVALS OF THE HOMEOWN£RS ASSOC/A 110N AND TH£ CITY OF CARLSBAD PLANNING DEPARTMENT. 8. AU LOTS MUST MAINTAIN A USABLE: 15-FOOT BY 15 FOOT REAR YARD AR£A. ONLY OP£N-ROOF TRELLIS OR OP£N-ROOF PA 110 COV£RS (E.G .. LA me£ PANELS OR MA T£RIALS ARRANGED PARALL£L TO EACH OTH£R AS 2• X 2• WOOD WITH SPACES B£TWE£N EACH PIECE) MAY EXTEND INTO TH£ /?£QUIRED 15-FOOT BY 15 FOOT REAR YARD AR£A. SPECIFIC DEV£LOPM£NT STANDARDS 1. ALL TR£LLIS/PATIO COVERS SHALL HAVE A MAXIMUM DEPTH OF NO MOR£ THAN 20 FEET AND MUST MAINTAIN A MINIMUM 5-FOOT S£TBACK FROM REAR ANO SID£ YARD F£NC£S, SOUND WALLS, OR COMMUNITY WALLS. 2. TH£ OUTSIDE £OGE OF A TR£LLIS/PA TIO COVER MUST MAINTAIN A MINIMUM DISTANCE OF 10 F££T FROM ANY ADJOINING DW£LUNG UNIT OR OTH£R TR£LLIS/PATIO COVER POST. A MAXIMUM OF 2 F££T OVERHAND IS ALLOW£0 PAST TH£ POST. J, TH£ LOCATION OF TRELLIS/PA TIO COVERS MAY BE MOOIFIEO FROM 7HE COVERAGE AR£A SP£C/FICALL Y ID£NT1FIEO BY THE TRELLIS/PA TIO COVER £XHIBIT, SUBJECT TO TH£ APPROVAL OF TH£ HOM£0WN£RS ASSOC/A 110N ANO THE CITY OF CARLSBAD PLANNING DEPARTMENT. LOT NUMBER FLOORPLAN TYPE: - I I ' \ • ' \ y \ ' I ' I ' I ' I ' I ' I ' ),. !1 I ' I /'ti,,, . It.~_ .. -'\ I I ' I ' I ,i I ' I ' I ' I ' I ' I ' I ' I ' I ' I ' I ' I /~ 17 r"' ,{ ' I / I I I I I ~ I I I I :~~~p:::::==fH I I u MAXIMUM LIMITS OF OPTIONAL AND PROPOSED DECKS PR.OJBCTDFSIGN C'oNsvtrANIS PLIMNNI • BM • wmu. • JINOI a • smmar/GPS 701 B 8-Suite800, S..~ CA !12101 61-S-6411 FAX 619-23,M13,49 I ' ~ MAXIMUM LIMITS OF PA nos COVERS (DEPTH NO MORE 7HAN20') (SEE NOT£ R£: 15'x15' USABLE AREA REQUIRED) ----------- h [2,,jR) 2C I @> IE] .....-n--. CLEARWA'TER STREET SHOREI.JNE DRIVE THE TIDES 0204060 120 1 0 GRAPHICAL SCALE ---------- WA7Ei'IS END DRIVE ® l2CRI ® [Ml @r-r--1 l2CRI h-'-' -- @> l3BRI \ -- ' I 1 j2CR1 -- 0 DECK & PA TIO COVER EXHIBIT POINSETTIA PROPERTIES CITY OF CARLSBAD, CALIFORNIA I I: SHEET 2 OF 2 N "2_ "' "2_ ,.., 0 "' " TI N I X w I 0 f'C « a. I "' u w ? VJ ~ ~ .c X w / 00 <o 0 N / ~ "' C: ;':'- ""