Loading...
HomeMy WebLinkAboutCT 98-08; ROMERIA ST CONDOS; Tentative Map ExhibitSAN D1£GO \ TW 90.0 H=6' --s4_0 BW 83.2 0 1 l,,o-----10.00'-----i •--~·,vr90:a· H;;,6~ FG 84.0 8 .20 TC B0.70 GT _]_··_.o "''" -•• .l.'.T--l,..LL...-~- 80,23 FL 4 ····-···---•T ,. ...... \ ' ' ' . ·,. ~: ' . . . . . ' N 00' 09' 46" W 233.51 EXIST 1' x 2' . GI !NN!TE -BIT€H--·--11--/- 6. H=S.5' C, ' j1~ 0-i i i 8 -~/JA r 11 I 1-\ 0 <,_0 -'\'¢" -M s H=8' 1,I C 78.30 TC 77.80 FS --- s \ 2% PEN SPACE • OPEN SPACE t:: - .... u ~ f/1 z .... 0.. 0 7'± SAFETY RAIUNG llil FLOOR SLAB ' ' I I ' -~L [_..J ~ EXIST SLOPE L,Ei:..,.;E:;::XIST RET. WALL PROP RET. WALi. SECTION A-A NO SCALE BLD WALL 2ND FLOOR FLOOR SLAB ,;,5r~ 30· ll!IGENERAL UTILITY. ACCESS AND DRAINAGE EASEMENT ~ RET. ALL DRIVEWAY 3" AC ON 6" CAL TRANS CLASS 11 GARAGE WATER PROOFING SECTION 8-8 & DRAINAGE PIPE PER SOIL REPORT ( IYF') NO SCALE 2ND FLOOR b ~ FLOOR SLAB PROP. RET WAU. (TYP) PROP. RET WAU. (TYP) • u ,_ · .. ,_ '-' --- ·- • -N N ... "' r--.: tO «J co ~ """"-LSL...L'<, «J 6. ~ @ l;;; ,..; ..,. ~ ~ BB I llil 30' 24' 1---------1-----H--1 s C GT •- . 1~ . co 6600' 8~ 83.03 TC 82.53 TG OPEN SPACE SECTION C-C NO SCALE __ ' ., ,P • ,W.'"-' ~, w CD ·-;-......._.10o TW 96.0 H=6' 8 9 I 58.4 TOF . I I 10 oo "? 0 a, • "' a, w a:, u.. u.. ~~ 0 If) ,-..: "' w l::: 0 ti --- 0 z N = o· <fl 10' ', . 10' 4.5' 5.5' ' - 7r ~tJI ',)"' II "' TW 102.5 H=4' II II II II II 10.U ~ FG 98.50 BW 97.8 ' TW 101.1 H=5' FG 96.0 BW 95.7 ~----11 -----100 60' 1GHT-0f WAY JO' • If JO" 20' 20' 10' , , 5.5' ' EXIST CVRfJ EXIST PA V£MEMT GUT7I:I? de ,:r, SJDcWALJ< --- I, , , , 4.5\. ' - TYPICAL STREET S£C710N ROMER/A STREET INFORMAnON ONLY -NOT A PART OF THIS PLAN NO SCALE LEGEND EXISTING CONTOUR PROPOSED CONTOUR EXISTING ELEVATION PROPOSED ELEVATION FINISH SURFACE, FINISH GRADE FINISH FLOOR ELEVATION TOP OF GRATE, INVERT £LE.VA TION CATCH BASIN B" PVC DRAIN PIPE (PR/VA TE} DAYLIGHT LINE DIRECTION OF FLOW TOP / TOE SLOPE CUT/ FILL SLOPE ( 2: 1 MAX } RETAINING WALL ( SEPARATE PERMIT} PROPOSED SEWER MAIN PROPOSED WATER MAIN PROPOSED 6" TYPE "G" CURB & GUTTER PROPOSED 6" TYPE "G" CURB CONCRETE DITCH ---280 ----· 276 505.80 505.16 FS, FG FFE TG, !E □ ----------------, 7 ---, r -- __ V_ ___ j/ __ _ -s--s-- -w---W- ASSESSSOR7S PARCEL NUMBER: 216-290-31 & 276-290-.J2 EX/S71NG ZONING: RD-M PROPOSED ZONING; PROPOSED ZONING: RD-M PROPOSED GENERAL PLAN RH TOTAL GROSS AREA O. 7.JS ACRE:s U71L/71ES: SCHOOL DISTRICT: TELEPHONE: FIRt PROTECTION: WATER DISTRICT: SEWER DISTRICT: ADT SAN DIEGU/TO UNION HIGH SCHOOL DISTRICT ENCINITAS UNION SCHOOL DISTRICT PACIFIC BELL CARLSBAD FIRE DISTRICT CARLSBAD MUNICIPAL WATER DISTRICT LEUCADIA COUNTY WATER DISTRICT A VER AGE DAILY RTAFFIC GENERA T£0 BY PROJECT -88 SITE DESIGN DA TA: LOT AREA: DENSITY; NO. OF LOTS/ UN/TS; USABLE OPf:N SPACE: BLDG. COVERAGE: OFF-STREET PARKING: RV PARKING: 0.735 ACRES 14.96 V/AC. 1 LOT/ 11 AIRSPACE UNITS 2780 SO. FT. 30% LOT AREA 6 (4 STD O 8.5X20 & 2 COMP. 0 8X15) 220 SO. FT. EARTHWORK QUAN7171ES: CUT.· 2800 CY FILL: 470 CY EXPORT.· 2.JIO CY SOURCE OF TOPOGRAPHY ANACAL ENGINEERING, DEC.2.J.1991 LEGAL DESCR/PTlON ENGINEER OF WORK ,.,._oFEss ClllfL £:NG/NEERING • LAND SUR\!cYING !:' -t, "' "' ., -~ $ • DAlF