Loading...
HomeMy WebLinkAboutCDP 2021-0020; KIDD ADU; Administrative DeterminationI I ' \\ I I I Area 320 SF Building Area Legend =:J 320SF \ i L ..l G 111 'I \ .r Ii ' 'I ,. rn d][1) DETACHED ADU ADDITION vicinnty map: PROJECT SITE: 7346 GREBE DRIVE ---- CARLSBAD, CA 92011 I EN INITAS RANCH/ GOLF COURSE / I / CITY OF CARLSBAD Administrative Permit Case No. C.DP .2ul I-{N2.() Exibit No . .,A -E Date Jfr~p2{[- ' ' project data: PROJECT OWNER = ERIK KIDD OWNER ADDRESS = 7346 GREBE DRIVE CARLSBAD, CALIFORNIA 92011 OWNER EMAIL = erikrkidd@hotmail.com OWNER PHONE = 210-207-2846 PROJECT ADDRESS = 7346 GREBE DRIVE CARLSBAD. CALIFORNIA 92011 0 ROJECT DESCRIPTION = ONE STORY DETACHED ACCESSORY DWELLING UNIT (ADU). THE ADU WILL BE PLACED IN THE NORTHWEST CORNER OF THE REAR YARD. THE ADU WILL HAVE A GREAT ROOM, KITCHEN WITH ISLAND, BATHROOM, BED AREA AND A LOFT. THE WEST FACING WALL WILL HAVE A LARGE SLIDING DOOR AND fHE SOUTH FACING WALL WILL HAVE TWO FRENCH DOORS AND A BIFOLDING WINDOW WITH AN OUTDOOR BAR TOP. THE ADU EXTERIOR WILL MATCH THE EXISTING RESIDENCE. LEGAL DESCRIPTION = LOT 17 MAP 13331 APN = 215-761-07-00 YEAR BUILT = 1988 GENERAL PLAN DESIGNATION= R-4 RESIDENTIAL SINGLE FAMILY OCCUPANCY = R-3 CONSTRUCTION TYPE = V-B ZONE = P-C LOT AREA = 9,000 SF BUILDING AREAS (G) 1 ST FLOOR RESIDENCE = 1,810SF (E) 2ND FLOOR RESIDENCE = 1 697 SF (E) MAIN RESIDENCE AREA = 3,507 SF (E) GARAGE AREA = 640 SF (N) DETACHED ADU = 320 SF LOT COVERAGE = [(1,810SF + 640SF + 320SF)/ 9,00DSF] X100%=31% FcOOR AREA RATIO = 3,507SF + 320SF/ 9,000SF= .42% BIJI LDING HEIGHT = 1s·-2·· #OF STORIES = ONE PARKING = EXISTING ATTACHED 3 CAR GARAGE GRADING = NONE REQUIRED OR PROPOSED FIRE SPRINKLERS = NONE REQUIRED OR PROPOSED BUILDING CODES = SEE CODE TABLE THIS SHEET - codes -construction: governing 20 ;9 CALIFORNIA BUILDING CODE TITLE 24 PART 2, V. 1&2 20·,9 CALIFORNIA RESIDENTIAL CODE TITLE 24 PART 2.5 20d CALIFORNIA ELECTRICAL CODE TITLE 24 PART 3 2019 CALIFORNIA MECHANICAL CODE TITLE 24 PART 4 20"9 CALIFORNIA PLUMBING CODE TITLE 24 PART 5 20,., CALIFORNIA ENERGY CODE TITLE 24 PART 6 20,9 CALIFORNIA FIRE CODE TITLE 24 PART 9 2Q"!g CALIFORNIA GREEN BUILDING CODE TITLE 24 PART 11 project team: ARCHITECT = DZN PARTNERS 682 SECOND ST ENCINITAS, CA 92024 760-753-2464 BART SMITH, AIA LEED AP b.smith@dznpartners.com PROJECT MANAGER = DZN PARTNERS City of Carlsbad 682 SECOND ST ENCINITAS, CA 92024 JUL 2 9 2021 760-753-2464 MARISOL BARBA marisol@dznpartners.com Planning Division' ~-I STRUCTURAL ENGINEER = PCS□ ENGINEERING CORP 3529 COASTVIEW COURT CARLSBAD, CA 92010 (760) 207-1885 PAUL CHRISTENSON paul.pcsd@gmail.com ENC:RGY ENGINEER = BEAR TECHNOLOGIES CONSULTING, INC. 3431 DON ARTURO DRIVE CARLSBAD, CA 92010 760-635-2327 WAYNE SEWARD wayne@beartechconsulting.com §heet index I I SHEET TITLE SHEET# ao.o TITLE SHEET a1 .o SITE PLAN a2.0 ABBREVIATIONS AND SYMBOLS a2.1 GENERAL NOTES a2.2 MUNICIPAL NOTES AND SCHEDULES a3.0 FLOOR PLAN a4.0 UTILITY PLANS as.a ROOF PLANS a6.0 EXTERIOR ELEVATIONS a7.0 BUILDING CROSS SECTIONS as.a ARCHITECTURAL DETAILS S1 FOUNDATION & ROOF PLAN SD1 STRUCTURAL DETAILS SN1 STRUCTURAL NOTES WSW1 STRONG WALL WSW WSW2 STRONG WALL WSW T-24.1 ENERGY REQUIREMENTS T-24.2 ENERGY REQU IREMENTS T-24.3 1 ENERGY REQU IREMENTS PROJECT# CDP 202 1-0020 AR PARTNERS 6 8 2 S E C O N D S T ENCINITAS.CA ( 7 6 o I 7 5 3 2 4 6 4 DZNPARTrlERS.CDM L ...J KIDD DETACHED ADU ADDITION CITY: CARLSBAD, CA 02/18/2021 07/26/2021 JOB: 202041 R TITLE SHEET aO.O (E) DIRT 16.§~ __ -____ .,,--...__ -4.06' 20.00' - (E) 6.0' HIGH, CEMENT PLASTER ----------,i,1 OVER 8" MASONRY FENCE (TYP.) 0 □ ~ :i" (N) WASTE LINE, TYP --------tt''---1-----_., -('-,. C\I T'"" T'"" T'"" :[ \ \ . ' ~r ~I ~ I !w~~ -~1 10.00' ' ' j SC-~I i/ ' (E) REPJSE // ' ( (E) WATER LATERAL, TYP -------_ __:\'<--__._i \ \ ! I ! I i I I __.-----(N)CLEANOUT,TYP ~-(E) LANDSCAPE (E) BALCONY ABOVE ------I ----------------I ----._J grading quantities CUT = 5CY FILL 0CY EXPORT 5CY IMPORT OCY NO REMDIAL GRADING ~----(E) 6.0' HIGH, CEMENT PLASTER OVER 8" MASONRY FENCE (TYP.) \ \ \ I \ \ \ I \ I \ \ \ \ J I ' I I \ \ \ I \ \ \ ' \ I \ ·, I I I I I I I I I I -~------------~----------··-···-------------------------------- PROPOSED ONE - STORY DETACHED ACCESSORY ~--------JI-~ DWELLING UNIT (ADU) 24.94' {E) SPA '0 BE RE'viOVEi:? SETBACK LINE (TYP.) -------l+;;cei'+-li ----, PROPERTY LINE (TYP.) -------• t' -('-,. C\I T'"" T'"" T'"" 10.00' ' 1=1=----- --/------- ~-(E) LANDSCAPE , I ,,i.cR\TCH1 <{;:-,;r -jO • C7?255L c::; °lJ, I\ c__::__ /: ,-:,/ l <; "-...._=--..) 8/31/2021 RENEWAL DATE Fer,;. PARTNERS 6 8 2 S E C O N D S T ENCINITAS.CA I 7 s o ) 7 5 3 2 4 s 4 DZNPARTNERS.C0M L J KIDD DETACHED ADU ADDITION CITY: CARLSBAD, CA 02/18/2021 07/26/2021 JOB: 202041 R SITE PLAN a1.0 . 0 "' /~\ , WH J '"---·_/ 8' -8" 2:.10 \ SKLT 4 a7.0 LOFT/STORA E SLP!J ClG, WD FLR SKLT .... 20' -O' 2 a7.0 Kl CHEN I I ENTO_J BELOW I _J -LPD CL ONCH.:_ 0 -·-·-·-·-·-·····------- ~ FRIGIDAIRE FFTH 1022R2 10,000 BTU ELECTRIC HEAT/COOL BUILT-IN AIR CONDITIONER, 20 AMP BREAKER WITH NEMA 6-20R RECEPTACLE, OAE 0 "' RHEEM ECOSENSE RETE-18 18KW 2.73 GMP ELECTRIC WATER HEATER, 2-40 -. " a:i 0 <Ii ::::, a, 0 <( -' ;,. "' "' "' "' "' 0 AMP BREAKERS, OAE 4' -O" ADU S.B. ; 20' -O' 8' -4" ' l I HVAc -,Ji 'L=c=. o==''--Jil BATH i D s dG•;,;;2ieS·DR 20· -o': - 11' -8" .... 5' -6" 3' -O" O.H. 26'71lFROR: . . ' :,~ ··;"~-~-'i'":'.. '~. ] ., ': ;;: 0 ;;: 0 ~ 0 '\-(. ffi __ "'"" ____ _ ~ I :c{·~_;: 0 · 0 n ~ .,, LlJ z "' Q_ ... • g, 00 -i=' o~i I +-r~,_,~cr;;r"'<_,:8...,:--------~-+1-~--+-------.1 -.u i -j :,-. . c-----· _ _.:._' -·-J ,, __ ; wall legend: = EXISTING 4" STUD WALL TO DEMOLISH EXISTING 4" STUD WALL TO REMAIN NEW 4" STUD WALL NEW 6" STUD WALL floor plan notes: 1. SEE SHEET a2.0 FOR ABBREVIATIONS AND SYMBOLS RELATING TO THE FLOOR PLAN. 2. SEE SHEET a2.2 FOR SCHEDULES RELATING TO THE FLOOR PLAN. 3. ALL MATERIALS, TEXTURES, AND COLORS TO BE SELECTED BY OWNER. 5. LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED AND HAVE A MINIMUM OR 36-INCHES MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCEED ¼-INCH PER FOOT. LANDINGS OR FINISHED FLOORS SHALL NOT BE MORE THAN 1.5 INCHES LOWER THAN THE TOP OF THE THRESHOLD FOR OUTWARD SWINGING EXTERIOR DOORS OR 7.75" FOR DOORS THAT DO NOT SWING OUTWARDS. R311.3. 6. GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE SHOWN ON THE PLANS AS SAFETY GLAZING MATERIAL IN ACCORDANCE WITH SECTION R308.4: A) GLAZING IN DOORS. B) GLAZING ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE. C) GLAZING IN THE WALLS/DOORS FACING OR CONTAINING BATHTUBS, SHOWERS, WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE STANDING SURFACE. EXCEPTION: GLAZING THAT IS MORE THAN 60", MEASURED HORIZONTALLY, FROM THE WATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SWIMMING POOL. 7. HANDRAILS (SECTION R311.7.8): a) SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH STAIRWAY WITH FOUR OR MORE RISERS. b) HANDRAILS AND EXTENSIONS SHALL BE 34" TO 38" ABOVE NOSING OF TREADS AND BE CONTINUOUS. c) THE HANDGRIP PORTION OF ALL HANDRAILS SHALL BE NOT LESS THAN 1-¼ INCHES NOR MORE THAN 2 INCHES IN CROSS-SECTIONAL DIMENSION. SEE SECTION R311.7.8.3 FOR ALTERNATIVES . d) HANDRAILS PROJECTING FROM WALLS SHALL HAVE AT LEAST 1-½ INCHES BETWEEN THE WALL AND THE HANDRAIL. 8. R311.7.1 WIDTH. STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 41/2 INCHES (114 MM) ON EITHER SIDE OF THE STAIRWAY AND THE CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698 MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. EXCEPTION: THE WIDTH OF SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R311.7.10.1. 9. R311.7.5.2 TREADS. THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM) 10. THE SUPPORTING CONSTRUCTION OF FIRE-RATED FLOOR ASSEMBLIES SHALL HAVE AN EQUAL OR GREATER FIRE-RATING. SECTION R302.3.1. 11. PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR--CEILINGS AND ROOF-CEILINGS SHALL BE PROTECTED AS REQUIRED IN CRC SECTION R302.4. 12. PER CEC ARTICLE 210.11(C)1, THERE WILL BE A MINIMUM OF 2 SMALL APPLIANCE BRANCH CIRCUITS WITHIN THE LOCATIONS SPECIFIED IN ARTICLE 210.52(B), I.E., KITCHEN AND DINING AREAS. "' :s: • C-22557 ;.L, ~-}-~11·1 I, (=-----/ -,:.,,~;\ ' j( ' ' ' ) ' ' 8/31/2021 RENEWAL DATE PARTNERS 6 8 2 S E C O N D S T ENCINITAS,CA (760)7532464 DZNPARTNERS.COM • L ..I KIDD DETACHED ADU ADDITION CITY: CARLSBAD, CA 02/18/2021 07/26/2021 JOB: 202041R FLOOR PLAN a3.0 (N) ALUi\lllNUM GtJTTER & DOWNSPOUT, TYP (N} UNE OF ROOF, TYP (1\1) UNE OF BUILDING. TYP (NJ SP;>J\liSH TILE ROOFING, TME, TYP. ::::, " 0 _<( ___ _ ------, __ ------, --------- {N} SKYi.JGHTS ----------j (E) PROPERTY LINE, TYP " I 0' 4' -0" ADU S.S. 1' -. ' {;H -- ..:. . ....i. ,.i __ '-·· -....... ; i I as.o • w ~ I 20' -O" 'J ' ' ' · ·•,j · ,' 1 t ,, ' ~-"--·;•"·+------.::. _____ , .... ___ --"~~;C::... 20' -0.i --- & I . ' ' \ a6.0 ! J -I. I '--,- I •• _ -------- 0 ' ' I ' 1 ! I --(N) ASP!lAL T SHINGLE ROOF!NG, TME. TYP. a6.0 roof plan notes: 1. §R806.1 ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION- RESISTANT METAL MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUM OPENINGS. 2. §R806.2 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT REDUCTION OF THE TOTAL AREA TO 1/300; IS PERMITTED PROVIDED THAT AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET BELOW THE RIDGE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA MAY BE REDUCED TO 1/300; WHEN A CLASS I OR II VAPOR BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. MINIMUM VENT AREA= 1/150 OF ATTIC AREA-NO (N) ATTIC AREA PROPOSED 3. §R806.2 WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1-INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT. 4. §R807.1 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR GREATER. THE VERTICAL HEIGHT SHALL BE MEASURED FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE UNDERSIDE OF THE ROOF FRAMING MEMBERS. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. WHEN LOCATED IN A WALL, THE OPENING SHALL BE MINIMUM OF 22 INCHES WIDE BY 30 INCHES HIGH. WHEN THE ACCESS IS LOCATED IN A CEILING, MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE 30 INCHES AT SOME POINT ABOVE THE ACCESS MEASURED VERTICALLY FROM THE BOTTOM OF CEILING FRAMING MEMBERS. SEE THE CALIFORNIA MECHANICAL CODE FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN A TT/CS. 5. NEW ROOF ASSEMBLIES TO ACHIEVE A CLASS 'A' ASSEMBLY. 6. ATTIC ACCESS SHALL BE A MINIMUM SIZE OPENING OF 22" x 30". THERE SHALL BE 30" HEADROOM CLEARANCE ABOVE THE OPENING. SECTION R807.1. 9. NEW SKYLIGHT WILL BE VELUX, VS-COS MODEL, COMPLIES WITH IBC SECTION 2405.5 -HALLMARK CERTIFIED PRODUCTS 426-H-695, 696,697,698. 10. NEW ROOF TO BE CLAY ROOF TILE, ICC-ESR-1489. TME. 11. REQUIRE EXHAUST FANS WITH A MINIMUM 100 CFM DUCTED TO THE EXTERIOR. DETAIL COMPLIANCE BY INCLUDING A COMPLYING EXHAUST FAN OR A DUCTED RANGE HOOD TO THE EXTERIOR. 12. ALL FANS INSTALLED TO MEET ALL OF THE PRECEDING VENTILATION REQUIREMENTS MUST BE SPECIFIED AT A NOISE RATING OF A MAXIMUM 1 "SONE" (CONTINUOUS USE) OR 3 "'SONE" (INTERMITTENT). • \ _¥;~25~ /C -'<-\ i J \, ,._.) vi;. J '.""\ 8/31/2021 RENEWAL DATE PARTNERS 6 8 2 S E C O N D S T ENCINITAS.CA ( 7 6 0 ) 7 5 3 2 4 6 4 DZNPARTNERS.COM L ..J KIDD DETACHED ADU ADDITION CITY: CARLSBAD, CA 02/18/2021 07/26/2021 JOB: 202041 R ROOF PLANS a5.0 (N) SKYLIGHT, TYP -----_ (N) SPANISH TILE ROOFING, ----- TME, TYP ---------.._ ------------ ...._ -----~--.... (N) CONTINUOUS PAINTED -;i~\'1: ALUMINUM GUTTER, TYP -----~ ----~ (N) METAL DRIP EDGE -----··-· -------,°' (N) 2X10 FASCIA BOARD,TME. TYP ==-=-_ -"_ =_ =_ =_=_--'_= _-1_.:b_:-...,1~ (N) 6X10 OUTRIGGER -- (N) STUCCO SIDING, TME, -----------+--<_.. TYP. (N) EXTERIOR LIGHT FIXTURE -------► (E) CMU WALL --------l>c EXISTING AND FINISH GRADE ~ ' (N) SPANISH TILE ROOFING, __ _ TME, TYP (N) SKYLIGHT, TYP (N) CONTINUOUS PAINTED ALUMINUM GUTTER, TYP _[N) METAL DRIP EDGE (N) 2X10 FASCIA BOARD,TME. TYP (N) 6X10 OUTRIGGER (N) FIBERGLASS ASPHALT SHINGLE ROOFING, TME. TYP. --·------. ~~~---- (N) STUCCO SIDING, TME, --------+-- TYP. (N) OUTDOOR COUNTER ----.._ EXISTING AND FINISH GRADE ~ L ~ UJ I c.,z .. :::; CXl t-UJ <fl ::, .. I< >I !I 4' -O" 4' -O" ~w '-' z -,:::; ID ... w <fl ::, C .. ti I< >I I I I I I I I I I I I I ROOF HT PL HT ' 1ST FLR DTP ~ + 112.08' + 108 8' LOFT FL "' LOFT~LRFF ~+--- -~ HDRHT "' C i:c-i -- EG/FG ROOF HT LOFT + 108.08' _1=ST FLR FF O +100.00' VII --t-PL HT ' 1ST FLR DTP ~ +112.08' <c I "' LOFT FL , <c I C, HDRHT I ----'I.-t!! ' - EGIFG LOFTF~RFF +10 8' ~ FLR ~ + 108.08' -~1~ST FL,.,,R_,,F.,__F~Ol"",.,I +100.00' VII ~W I ...J I '-' z -.. -a. ...I -ID W ... - w b I (N) SKYLIGHT, TYP ~ -__ 4'. O" (N) SPANISH TILE ROOFING, ~~1 --. =!_ TME, TYP ·-....--.._ ---- (N) METAL DRIP EDGE ----~---- (N) 6X10 OUTRIGGER ·· (N) CONTINUOUS PAINTED /1,,_..,/· ALUMINUM GUTTER, TYP __ ,.-c (N) STUCCO SIDING, TME, ----1------+f- TYP. (N) EXTERIOR LIGHT FIXTURE ----t=------+t- (E) PERIMETER WALL ----; EXISTING AND FINISH GRADE ~ I -I (N) SPANISH TILE ROOFING, ____ I TME, TYP ---- (N) SKYLIGHT, TYP (N) CONTINUOUS PAINTED ALUMINUM GUTTER, TVP __ {N_LMETAL DRIP_J:DG~ (N) 2X10 FASCIA BOARD,TME. TV? (N) 6X10 OUTRIGGER --c,,'- (NJ STUCCO SIDING, TME, TYP. - ,_ (N) EXTERIOR LIGHT FIXTURE ----;::: ===::::F; (E) PERIMETER WALL ----F EXISTING AND FINISH GRADE --- II elevation notes: 1. ROOF PLAN NOTES THE LOCATION OF GUTTERS AND DOWNSPOUTS. 2. ROOF PLAN NOTES THE LOCATION OF ROOF MOUNTED ATTIC VENTS. 3. EXTERIOR FINISHES WILL MATCH EXISTING HOME PURSUANT TO CMG SECTION 21 .10.030(E)(7). ROOF HT PL HT 1 C, .' L . ' ' :l ROOF HT PLHT . "' "' LOFT FL , --".':!'< c HDRHT EG/FG "' EG/FG door schedule 1ST FLR DTP +112.08' LOFT FLR FF -+108.58' LOFT Fl.R + 108.08' ·=---1ST FLR FF! + 100.00' 1ST FLR DTP +112.08' LOFT FLR FF +108-:58' LOFT FlR + 108.08' ~ ~ ~ Mark I Width I Height I Head Height I Type I Level I Comments 01 2' -6" 7' -O" 7' -O" 2670 FRENCH DOOR 1ST FLR FF TG 02 2' -6" 7 -O" 7' -O" 2670 FRENCH DOOR 1ST FLR FF TG 04 2' -4" 6' -8" 6' -8" 2468 SINGLE PANEL 1ST FLR FF 11 15' -11" 6' -11 1 /2" 6' -111/2" Door-MultiGlide-Andersen-Contemporary_ 1ST FLR FF TG Clad-Interior Stacking window schedule Mark I Width I Height Head Height I Type I Level I Comments 01 3' -O" 3' -011 7' -O" 3030 -VERTICAL SLIDER 1ST FLR FF TG 02 8' -O" 3' -6" 7' -O" 8036 4 PANEL Bl-FOLD 1ST FLR FF NEW, TG 03 81 -O" 2' -O" 3' -6" Arch Window 16301 LOFT FLR FF 04 2' -O" 4' -6'' 2046 OPERABLE SKYLIGHT 1ST FLR DTP 05 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP NEW 06 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP NEW 07 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP • C-22557 ~Ylf\,_ 8/31/2023 RENEWAL DATE F CAI.. PARTNERS 6 8 2 S E C O N D S T ENCINITAS .CA (760)7532464 D2NPARTNERS.COM L .J KIDD DETACHED ADU ADDITION CITY: CARLSBAD, CA 02/18/2021 09/02/2021 JOB: 202041R EXTERIOR ELEVATIONS a6.0