HomeMy WebLinkAboutCDP 2021-0020; KIDD ADU; Administrative DeterminationI
I
' \\
I
I
I Area
320 SF
Building Area Legend
=:J 320SF
\
i
L ..l
G 111
'I
\ .r Ii
' 'I ,.
rn d][1)
DETACHED ADU ADDITION
vicinnty map:
PROJECT SITE:
7346 GREBE DRIVE ----
CARLSBAD, CA 92011 I
EN INITAS RANCH/
GOLF COURSE /
I /
CITY OF CARLSBAD
Administrative Permit
Case No. C.DP .2ul I-{N2.()
Exibit No . .,A -E Date Jfr~p2{[-
' '
project data:
PROJECT OWNER = ERIK KIDD
OWNER ADDRESS = 7346 GREBE DRIVE
CARLSBAD, CALIFORNIA 92011
OWNER EMAIL = erikrkidd@hotmail.com
OWNER PHONE = 210-207-2846
PROJECT ADDRESS = 7346 GREBE DRIVE
CARLSBAD. CALIFORNIA 92011
0 ROJECT DESCRIPTION = ONE STORY DETACHED ACCESSORY
DWELLING UNIT (ADU). THE ADU WILL BE PLACED IN THE NORTHWEST CORNER OF THE
REAR YARD. THE ADU WILL HAVE A GREAT ROOM, KITCHEN WITH ISLAND, BATHROOM,
BED AREA AND A LOFT. THE WEST FACING WALL WILL HAVE A LARGE SLIDING DOOR AND
fHE SOUTH FACING WALL WILL HAVE TWO FRENCH DOORS AND A BIFOLDING WINDOW
WITH AN OUTDOOR BAR TOP. THE ADU EXTERIOR WILL MATCH THE EXISTING
RESIDENCE.
LEGAL DESCRIPTION = LOT 17 MAP 13331
APN = 215-761-07-00
YEAR BUILT = 1988
GENERAL PLAN DESIGNATION= R-4 RESIDENTIAL SINGLE FAMILY
OCCUPANCY = R-3
CONSTRUCTION TYPE = V-B
ZONE = P-C
LOT AREA = 9,000 SF
BUILDING AREAS
(G) 1 ST FLOOR RESIDENCE = 1,810SF
(E) 2ND FLOOR RESIDENCE = 1 697 SF
(E) MAIN RESIDENCE AREA = 3,507 SF
(E) GARAGE AREA = 640 SF
(N) DETACHED ADU = 320 SF
LOT COVERAGE = [(1,810SF + 640SF + 320SF)/ 9,00DSF] X100%=31%
FcOOR AREA RATIO = 3,507SF + 320SF/ 9,000SF= .42%
BIJI LDING HEIGHT = 1s·-2··
#OF STORIES = ONE
PARKING = EXISTING ATTACHED 3 CAR GARAGE
GRADING = NONE REQUIRED OR PROPOSED
FIRE SPRINKLERS = NONE REQUIRED OR PROPOSED
BUILDING CODES = SEE CODE TABLE THIS SHEET
-
codes -construction: governing
20 ;9 CALIFORNIA BUILDING CODE TITLE 24 PART 2, V. 1&2 20·,9 CALIFORNIA RESIDENTIAL CODE TITLE 24 PART 2.5
20d CALIFORNIA ELECTRICAL CODE TITLE 24 PART 3 2019 CALIFORNIA MECHANICAL CODE TITLE 24 PART 4 20"9 CALIFORNIA PLUMBING CODE TITLE 24 PART 5 20,., CALIFORNIA ENERGY CODE TITLE 24 PART 6 20,9 CALIFORNIA FIRE CODE TITLE 24 PART 9 2Q"!g CALIFORNIA GREEN BUILDING CODE TITLE 24 PART 11
project team:
ARCHITECT = DZN PARTNERS
682 SECOND ST
ENCINITAS, CA 92024
760-753-2464
BART SMITH, AIA LEED AP
b.smith@dznpartners.com
PROJECT MANAGER = DZN PARTNERS City of Carlsbad 682 SECOND ST
ENCINITAS, CA 92024 JUL 2 9 2021 760-753-2464
MARISOL BARBA
marisol@dznpartners.com Planning Division' ~-I
STRUCTURAL ENGINEER = PCS□ ENGINEERING CORP
3529 COASTVIEW COURT
CARLSBAD, CA 92010
(760) 207-1885
PAUL CHRISTENSON
paul.pcsd@gmail.com
ENC:RGY ENGINEER = BEAR TECHNOLOGIES CONSULTING, INC.
3431 DON ARTURO DRIVE
CARLSBAD, CA 92010
760-635-2327
WAYNE SEWARD
wayne@beartechconsulting.com
§heet index
I I SHEET TITLE SHEET#
ao.o TITLE SHEET
a1 .o SITE PLAN
a2.0 ABBREVIATIONS AND SYMBOLS
a2.1 GENERAL NOTES
a2.2 MUNICIPAL NOTES AND SCHEDULES
a3.0 FLOOR PLAN
a4.0 UTILITY PLANS
as.a ROOF PLANS
a6.0 EXTERIOR ELEVATIONS
a7.0 BUILDING CROSS SECTIONS
as.a ARCHITECTURAL DETAILS
S1 FOUNDATION & ROOF PLAN
SD1 STRUCTURAL DETAILS
SN1 STRUCTURAL NOTES
WSW1 STRONG WALL WSW
WSW2 STRONG WALL WSW
T-24.1 ENERGY REQUIREMENTS
T-24.2 ENERGY REQU IREMENTS
T-24.3 1 ENERGY REQU IREMENTS
PROJECT# CDP 202 1-0020
AR
PARTNERS
6 8 2 S E C O N D S T
ENCINITAS.CA
( 7 6 o I 7 5 3 2 4 6 4
DZNPARTrlERS.CDM
L ...J
KIDD
DETACHED
ADU ADDITION
CITY: CARLSBAD, CA
02/18/2021
07/26/2021
JOB: 202041 R
TITLE SHEET
aO.O
(E) DIRT 16.§~ __ -____ .,,--...__
-4.06' 20.00' -
(E) 6.0' HIGH, CEMENT PLASTER ----------,i,1
OVER 8" MASONRY FENCE (TYP.)
0 □ ~
:i" (N) WASTE LINE, TYP --------tt''---1-----_.,
-('-,.
C\I
T'""
T'""
T'""
:[ \
\
.
'
~r
~I
~ I !w~~
-~1 10.00'
'
' j SC-~I i/ '
(E)
REPJSE //
'
(
(E) WATER LATERAL, TYP -------_ __:\'<--__._i
\
\
! I
! I
i I
I
__.-----(N)CLEANOUT,TYP
~-(E) LANDSCAPE
(E) BALCONY
ABOVE
------I ----------------I ----._J
grading quantities
CUT = 5CY
FILL 0CY
EXPORT 5CY
IMPORT OCY
NO REMDIAL GRADING
~----(E) 6.0' HIGH, CEMENT PLASTER
OVER 8" MASONRY FENCE (TYP.)
\
\
\
I
\
\
\
I
\
I
\
\
\
\
J
I
' I
I
\
\
\
I
\
\
\
' \
I \ ·, I I
I
I
I
I
I
I
I
I
-~------------~----------··-···--------------------------------
PROPOSED ONE -
STORY DETACHED
ACCESSORY ~--------JI-~
DWELLING UNIT
(ADU)
24.94'
{E) SPA '0
BE RE'viOVEi:?
SETBACK LINE (TYP.) -------l+;;cei'+-li ----,
PROPERTY LINE (TYP.) -------• t'
-('-,.
C\I
T'""
T'""
T'""
10.00'
'
1=1=-----
--/-------
~-(E) LANDSCAPE
,
I
,,i.cR\TCH1
<{;:-,;r -jO
• C7?255L c::; °lJ, I\ c__::__ /: ,-:,/ l <; "-...._=--..)
8/31/2021
RENEWAL
DATE
Fer,;.
PARTNERS
6 8 2 S E C O N D S T
ENCINITAS.CA
I 7 s o ) 7 5 3 2 4 s 4
DZNPARTNERS.C0M
L J
KIDD
DETACHED
ADU ADDITION
CITY: CARLSBAD, CA
02/18/2021
07/26/2021
JOB: 202041 R
SITE PLAN
a1.0
.
0
"'
/~\
, WH J
'"---·_/
8' -8"
2:.10
\ SKLT
4
a7.0
LOFT/STORA E
SLP!J ClG, WD FLR
SKLT
....
20' -O'
2
a7.0
Kl CHEN
I I
ENTO_J
BELOW
I
_J
-LPD CL
ONCH.:_
0
-·-·-·-·-·-·····-------
~
FRIGIDAIRE FFTH 1022R2
10,000 BTU ELECTRIC HEAT/COOL
BUILT-IN AIR CONDITIONER, 20 AMP
BREAKER WITH NEMA 6-20R
RECEPTACLE, OAE
0
"'
RHEEM ECOSENSE RETE-18
18KW 2.73 GMP
ELECTRIC WATER HEATER, 2-40 -.
" a:i
0 <Ii
::::, a, 0
<(
-' ;,. "'
"' "' "'
"' 0
AMP BREAKERS, OAE
4' -O"
ADU S.B.
;
20' -O'
8' -4"
' l I HVAc
-,Ji 'L=c=. o==''--Jil
BATH
i D s dG•;,;;2ieS·DR
20· -o':
-
11' -8"
....
5' -6"
3' -O"
O.H.
26'71lFROR:
.
. ' :,~
··;"~-~-'i'":'.. '~.
] ., ':
;;:
0 ;;:
0 ~
0 '\-(. ffi
__ "'"" ____ _
~ I :c{·~_;: 0 · 0
n ~ .,,
LlJ z "' Q_ ... • g,
00
-i=' o~i I +-r~,_,~cr;;r"'<_,:8...,:--------~-+1-~--+-------.1
-.u i
-j :,-. . c-----· _ _.:._' -·-J ,, __ ;
wall legend:
= EXISTING 4" STUD WALL TO DEMOLISH
EXISTING 4" STUD WALL TO REMAIN
NEW 4" STUD WALL
NEW 6" STUD WALL
floor plan notes:
1. SEE SHEET a2.0 FOR ABBREVIATIONS AND SYMBOLS RELATING TO THE
FLOOR PLAN.
2. SEE SHEET a2.2 FOR SCHEDULES RELATING TO THE FLOOR PLAN.
3. ALL MATERIALS, TEXTURES, AND COLORS TO BE SELECTED BY
OWNER.
5. LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR
FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH
LANDING SHALL NOT BE LESS THAN THE DOOR SERVED AND HAVE A
MINIMUM OR 36-INCHES MEASURED IN THE DIRECTION OF TRAVEL.
EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT
TO EXCEED ¼-INCH PER FOOT. LANDINGS OR FINISHED FLOORS
SHALL NOT BE MORE THAN 1.5 INCHES LOWER THAN THE TOP OF THE
THRESHOLD FOR OUTWARD SWINGING EXTERIOR DOORS OR 7.75" FOR
DOORS THAT DO NOT SWING OUTWARDS. R311.3.
6. GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE SHOWN ON THE
PLANS AS SAFETY GLAZING MATERIAL IN ACCORDANCE WITH
SECTION R308.4:
A) GLAZING IN DOORS.
B) GLAZING ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL
EDGE OF THE GLAZING IS WITHIN A 24" ARC OF EITHER VERTICAL EDGE
OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM
EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE
WALKING SURFACE.
C) GLAZING IN THE WALLS/DOORS FACING OR CONTAINING
BATHTUBS, SHOWERS, WHERE THE BOTTOM EXPOSED EDGE OF THE
GLAZING IS LESS THAN 60" ABOVE THE STANDING SURFACE.
EXCEPTION: GLAZING THAT IS MORE THAN 60", MEASURED
HORIZONTALLY, FROM THE WATER'S EDGE OF A BATHTUB, HOT TUB,
SPA, WHIRLPOOL OR SWIMMING POOL.
7. HANDRAILS (SECTION R311.7.8):
a) SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH STAIRWAY
WITH FOUR OR MORE RISERS.
b) HANDRAILS AND EXTENSIONS SHALL BE 34" TO 38" ABOVE NOSING
OF TREADS AND BE CONTINUOUS.
c) THE HANDGRIP PORTION OF ALL HANDRAILS SHALL BE NOT LESS
THAN 1-¼ INCHES NOR MORE THAN 2 INCHES IN CROSS-SECTIONAL
DIMENSION. SEE
SECTION R311.7.8.3 FOR ALTERNATIVES .
d) HANDRAILS PROJECTING FROM WALLS SHALL HAVE AT LEAST 1-½
INCHES BETWEEN THE WALL AND THE HANDRAIL.
8. R311.7.1 WIDTH. STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914
MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL
HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS
SHALL NOT PROJECT MORE THAN 41/2 INCHES (114 MM) ON EITHER
SIDE OF THE STAIRWAY AND THE CLEAR WIDTH OF THE
STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS
AND LANDINGS, SHALL BE NOT LESS THAN 311/2 INCHES (787 MM)
WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698
MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES.
EXCEPTION: THE WIDTH OF SPIRAL STAIRWAYS SHALL BE IN
ACCORDANCE WITH SECTION R311.7.10.1.
9. R311.7.5.2 TREADS. THE TREAD DEPTH SHALL BE NOT LESS THAN 10
INCHES (254 MM). THE TREAD DEPTH SHALL
BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF
THE FOREMOST PROJECTION OF ADJACENT TREADS
AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE
GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS
SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM)
10. THE SUPPORTING CONSTRUCTION OF FIRE-RATED FLOOR ASSEMBLIES
SHALL HAVE AN EQUAL OR GREATER FIRE-RATING. SECTION R302.3.1.
11. PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR--CEILINGS AND
ROOF-CEILINGS SHALL BE PROTECTED AS REQUIRED IN CRC SECTION
R302.4.
12. PER CEC ARTICLE 210.11(C)1, THERE WILL BE A MINIMUM OF 2 SMALL
APPLIANCE BRANCH CIRCUITS WITHIN THE LOCATIONS SPECIFIED IN
ARTICLE 210.52(B), I.E., KITCHEN AND DINING AREAS.
"' :s:
• C-22557
;.L, ~-}-~11·1 I, (=-----/ -,:.,,~;\ ' j( '
' ' ) ' ' 8/31/2021
RENEWAL
DATE
PARTNERS
6 8 2 S E C O N D S T
ENCINITAS,CA
(760)7532464
DZNPARTNERS.COM
•
L ..I
KIDD
DETACHED
ADU ADDITION
CITY: CARLSBAD, CA
02/18/2021
07/26/2021
JOB: 202041R
FLOOR PLAN
a3.0
(N) ALUi\lllNUM GtJTTER &
DOWNSPOUT, TYP
(N} UNE OF ROOF, TYP
(1\1) UNE OF BUILDING. TYP
(NJ SP;>J\liSH TILE ROOFING, TME,
TYP.
::::,
" 0 _<( ___ _
------, __ ------, ---------
{N} SKYi.JGHTS ----------j
(E) PROPERTY LINE, TYP
" I 0'
4' -0"
ADU S.S.
1' -. ' {;H --
..:. . ....i. ,.i __ '-·· -.......
; i I as.o • w
~ I
20' -O"
'J ' ' ' · ·•,j · ,' 1 t ,,
' ~-"--·;•"·+------.::. _____ , .... ___ --"~~;C::...
20' -0.i
---
&
I .
' '
\ a6.0 !
J -I.
I
'--,-
I •• _
--------
0
'
' I
'
1 !
I
--(N) ASP!lAL T SHINGLE ROOF!NG,
TME. TYP.
a6.0
roof plan notes:
1. §R806.1 ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-
RESISTANT METAL MESH WITH 1/16" MINIMUM TO 1/4" MAXIMUM OPENINGS.
2. §R806.2 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN
1/150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT REDUCTION OF
THE TOTAL AREA TO 1/300; IS PERMITTED PROVIDED THAT AT LEAST 50 PERCENT
AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO
BE VENTILATED AT LEAST 3 FEET BELOW THE RIDGE OR CORNICE VENTS WITH
THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE
VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA MAY BE
REDUCED TO 1/300; WHEN A CLASS I OR II VAPOR BARRIER IS INSTALLED ON THE
WARM-IN-WINTER SIDE OF THE CEILING.
MINIMUM VENT AREA= 1/150 OF ATTIC AREA-NO (N) ATTIC AREA PROPOSED
3. §R806.2 WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL
NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1-INCH SPACE SHALL BE
PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE
LOCATION OF THE VENT.
4. §R807.1 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION
SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30
SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR GREATER. THE
VERTICAL HEIGHT SHALL BE MEASURED FROM THE TOP OF THE CEILING
FRAMING MEMBERS TO THE UNDERSIDE OF THE ROOF FRAMING MEMBERS.
THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30
INCHES AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
LOCATION. WHEN LOCATED IN A WALL, THE OPENING SHALL BE MINIMUM OF 22
INCHES WIDE BY 30 INCHES HIGH. WHEN THE ACCESS IS LOCATED IN A CEILING,
MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE 30 INCHES
AT SOME POINT ABOVE THE ACCESS MEASURED VERTICALLY FROM THE
BOTTOM OF CEILING FRAMING MEMBERS. SEE THE CALIFORNIA MECHANICAL
CODE FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS
LOCATED IN A TT/CS.
5. NEW ROOF ASSEMBLIES TO ACHIEVE A CLASS 'A' ASSEMBLY.
6. ATTIC ACCESS SHALL BE A MINIMUM SIZE OPENING OF 22" x 30". THERE SHALL BE 30"
HEADROOM CLEARANCE ABOVE THE OPENING. SECTION R807.1.
9. NEW SKYLIGHT WILL BE VELUX, VS-COS MODEL, COMPLIES WITH IBC SECTION
2405.5 -HALLMARK CERTIFIED PRODUCTS 426-H-695, 696,697,698.
10. NEW ROOF TO BE CLAY ROOF TILE, ICC-ESR-1489. TME.
11. REQUIRE EXHAUST FANS WITH A MINIMUM 100 CFM DUCTED TO THE EXTERIOR.
DETAIL COMPLIANCE BY INCLUDING A COMPLYING EXHAUST FAN OR A DUCTED
RANGE HOOD TO THE EXTERIOR.
12. ALL FANS INSTALLED TO MEET ALL OF THE PRECEDING VENTILATION REQUIREMENTS
MUST BE SPECIFIED AT A NOISE RATING OF A MAXIMUM 1 "SONE" (CONTINUOUS USE)
OR 3 "'SONE" (INTERMITTENT).
• \ _¥;~25~
/C -'<-\ i J \, ,._.) vi;. J '.""\
8/31/2021
RENEWAL
DATE
PARTNERS
6 8 2 S E C O N D S T
ENCINITAS.CA
( 7 6 0 ) 7 5 3 2 4 6 4
DZNPARTNERS.COM
L ..J
KIDD
DETACHED
ADU ADDITION
CITY: CARLSBAD, CA
02/18/2021
07/26/2021
JOB: 202041 R
ROOF PLANS
a5.0
(N) SKYLIGHT, TYP -----_
(N) SPANISH TILE ROOFING, -----
TME, TYP ---------.._ ------------
...._ -----~--.... (N) CONTINUOUS PAINTED -;i~\'1:
ALUMINUM GUTTER, TYP -----~ ----~ (N) METAL DRIP EDGE -----··-· -------,°'
(N) 2X10 FASCIA BOARD,TME. TYP ==-=-_ -"_ =_ =_ =_=_--'_= _-1_.:b_:-...,1~
(N) 6X10 OUTRIGGER --
(N) STUCCO SIDING, TME, -----------+--<_..
TYP.
(N) EXTERIOR LIGHT FIXTURE -------►
(E) CMU WALL --------l>c
EXISTING AND
FINISH GRADE ~
'
(N) SPANISH TILE ROOFING, __ _
TME, TYP
(N) SKYLIGHT, TYP
(N) CONTINUOUS PAINTED
ALUMINUM GUTTER, TYP
_[N) METAL DRIP EDGE
(N) 2X10 FASCIA BOARD,TME. TYP
(N) 6X10 OUTRIGGER
(N) FIBERGLASS ASPHALT
SHINGLE ROOFING, TME. TYP. --·------. ~~~----
(N) STUCCO SIDING, TME, --------+--
TYP.
(N) OUTDOOR COUNTER ----.._
EXISTING AND
FINISH GRADE ~
L
~ UJ I c.,z .. :::;
CXl t-UJ <fl
::, ..
I< >I
!I
4' -O"
4' -O"
~w '-' z -,:::;
ID ... w
<fl
::,
C ..
ti
I< >I
I
I
I
I
I
I
I
I
I
I
I
I
ROOF HT
PL HT
'
1ST FLR DTP ~
+ 112.08'
+ 108 8' LOFT FL "'
LOFT~LRFF
~+---
-~ HDRHT "'
C i:c-i --
EG/FG
ROOF HT
LOFT
+ 108.08'
_1=ST FLR FF O
+100.00' VII
--t-PL HT
'
1ST FLR DTP ~
+112.08'
<c I "' LOFT FL ,
<c I C,
HDRHT
I ----'I.-t!!
' -
EGIFG
LOFTF~RFF
+10 8'
~ FLR ~
+ 108.08'
-~1~ST FL,.,,R_,,F.,__F~Ol"",.,I
+100.00' VII
~W I ...J I '-' z -.. -a.
...I -ID W ... -
w b I (N) SKYLIGHT, TYP ~ -__ 4'. O"
(N) SPANISH TILE ROOFING, ~~1 --. =!_
TME, TYP ·-....--.._ ----
(N) METAL DRIP EDGE ----~----
(N) 6X10 OUTRIGGER ··
(N) CONTINUOUS PAINTED /1,,_..,/·
ALUMINUM GUTTER, TYP __ ,.-c
(N) STUCCO SIDING, TME, ----1------+f-
TYP.
(N) EXTERIOR LIGHT FIXTURE ----t=------+t-
(E) PERIMETER WALL ----;
EXISTING AND
FINISH GRADE
~ I -I
(N) SPANISH TILE ROOFING, ____ I
TME, TYP ----
(N) SKYLIGHT, TYP
(N) CONTINUOUS PAINTED
ALUMINUM GUTTER, TVP
__ {N_LMETAL DRIP_J:DG~
(N) 2X10 FASCIA BOARD,TME. TV?
(N) 6X10 OUTRIGGER
--c,,'-
(NJ STUCCO SIDING, TME,
TYP. -
,_
(N) EXTERIOR LIGHT FIXTURE ----;::: ===::::F;
(E) PERIMETER WALL ----F
EXISTING AND
FINISH GRADE ---
II
elevation notes:
1. ROOF PLAN NOTES THE LOCATION OF GUTTERS AND DOWNSPOUTS.
2. ROOF PLAN NOTES THE LOCATION OF ROOF MOUNTED ATTIC VENTS.
3. EXTERIOR FINISHES WILL MATCH EXISTING HOME PURSUANT TO CMG SECTION
21 .10.030(E)(7).
ROOF HT
PL HT 1
C, .' L
. ' ' :l
ROOF HT
PLHT
. "'
"' LOFT FL , --".':!'<
c HDRHT
EG/FG
"'
EG/FG
door schedule
1ST FLR DTP
+112.08'
LOFT FLR FF
-+108.58'
LOFT Fl.R
+ 108.08'
·=---1ST FLR FF!
+ 100.00'
1ST FLR DTP
+112.08'
LOFT FLR FF
+108-:58'
LOFT FlR
+ 108.08'
~
~
~
Mark I Width I Height I Head Height I Type I Level I Comments
01 2' -6" 7' -O" 7' -O" 2670 FRENCH DOOR 1ST FLR FF TG
02 2' -6" 7 -O" 7' -O" 2670 FRENCH DOOR 1ST FLR FF TG
04 2' -4" 6' -8" 6' -8" 2468 SINGLE PANEL 1ST FLR FF
11 15' -11" 6' -11 1 /2" 6' -111/2" Door-MultiGlide-Andersen-Contemporary_ 1ST FLR FF TG
Clad-Interior Stacking
window schedule
Mark I Width I Height Head Height I Type I Level I Comments
01 3' -O" 3' -011 7' -O" 3030 -VERTICAL SLIDER 1ST FLR FF TG
02 8' -O" 3' -6" 7' -O" 8036 4 PANEL Bl-FOLD 1ST FLR FF NEW, TG
03 81 -O" 2' -O" 3' -6" Arch Window 16301 LOFT FLR FF
04 2' -O" 4' -6'' 2046 OPERABLE SKYLIGHT 1ST FLR DTP
05 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP NEW
06 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP NEW
07 2' -O" 4' -6" 2046 OPERABLE SKYLIGHT 1ST FLR DTP
• C-22557
~Ylf\,_
8/31/2023
RENEWAL DATE
F CAI..
PARTNERS
6 8 2 S E C O N D S T
ENCINITAS .CA
(760)7532464
D2NPARTNERS.COM
L .J
KIDD
DETACHED
ADU ADDITION
CITY: CARLSBAD, CA
02/18/2021
09/02/2021
JOB: 202041R
EXTERIOR
ELEVATIONS
a6.0