Loading...
HomeMy WebLinkAboutCUP 2020-0004; KYLLE SEBREE STUDIO; Administrative DeterminationDIRECTORY TENANT CONTACT/APPLICANT KYLLE SEBREE STUDIO Contact: Kylie Sebree 3500 Roosevelt Street, Unit B Carlsbad, CA 92008 Phone: 7 60.27 4.4245 Email: kyllesebree@gmail.com BUILDING OWNER 3135-3181 TYLER PROPERTIES LLC. APN: 204-010-03-00 AND 204-010-04-00 ONE LEGAL LOT PER TITLE REPORT Contact: Matt Hall (Member Manager) 2604-B El Camino Real PMB#334 Carlsbad, CA 92008 Phone: 760.801.8055 Email: MHall4046@gmail.com LOCATION MAP NOTTO SCALE NOTTO SCALE DESIGNER OF RECORD BHG DESIGNS Contact: Brian H. Garrett l 7215 Rockhouse Rd. Ramona, CA 92065 Phone: 619.944.4810 Email: Brian@BHGDesigns.net ,,, ,, ,::/ c'; ,'-' ', , , , : ' , ',, , , ' -.111...JS.EH·.PERMf'f TRUE NORTH SPECIAL INSPECTION & OFF-SITE FABRICATION STRUCTURAL OBSERVATION SPECIAL INSPECTION: 0 YES ONO STRUCTURAL OBSERVATION: 0 YES ONO OFF-SITE FABRICATION: 0 YES ONO UTILITY/ SERVICE DISTRICTS WATER: SEWER: SCHOOL: CARLSBAD MUNICIPAL WATER DISTRICT (7 60.438.2722) CITY OF CARLSBAD WASTEWATER DIVISION (7 60.438.2722) CARLSBAD UNIFIED SCHOOL DISTRICT (7 60.33 l .5000) TRAFFIC IMPACT(ADT): AVG. DAILY TRAFFIC PER SANDAG (NOT SO) BREIF GUIDE INDUSTRIAL: MANUFACTURING/ASSEMBLY= 4 / 1,000 SQ.FT. PRODUCTION/FABRICATION AREA {INCLUDES RESTROOM) 2,940 I 1,000 = 2.94 X4 = l l .76 = 12 ADT EXISTING GYM (CREDIT) = 30 / 1,000 SQ.FT. DRAWING INDEX NO. SHT. NO. SHEET TITLE Tl TITLE SHEET, DRAWING INDEX, STANDARDS AND CODES 2 SPl OVERALL SITE PLAN f--2 t----+-------+--------------------------------, "" LUt----+-------+--------------------------------, ~ 3 Al EXISTING FLOOR PLAN -(NO PROPOSED CHANGES) U) i------+------i----------~-------~---------------, ::::J <(i------+------t---------------------------------, Zt----+------t----------------------------_____, 0 f-t----+------t---------------------------------' 0 4 A2 EXTERIOR ELEVATIONS Zt----+-----+--------------------------------, 0 Ut----+-----+--------------------------------' WATER DEMAND PER CARLSBAD MUNICIPAL CODE VOL. 2: 3.2. l .B NON-RESIDENTIAL: AVG. DAILY FLOW = 2,300 GPD / l 0,000 SQ.FT. .23 GPD (PER l ,000) X 2,940 SQ. FT.= 676 GPO (GALLONS PER DAY) SEWER GENERATION: DFU PER TABLE 702. l OF THE C.P.C.: PER TABLE 610.3 OF THE C.P.C.: (E) WATER SUPPLY FIXTURE UNITS (WSFU) IS 3.5 PER TABLE 610.4 OF THE C.PC.: MAX. l 00 FT LENGTH AT 46 TO 60 PSI WITH ¾" SUPPLY PIPE AND METER CURRENTLY SUPPORTS EXISTING WSFU. CURRENT DRAINAGE FIXTURE UNITS (DFU) IS 5 THE DFU IS WELL UNDER THE MIN. REQUIREMENT FOR THE EXISTING SIZE OF THE 4" SEWER DRAIN CONDITIONS. SEWER GENERATION IMPACT: EDU GYM INCLUDING TOILET ROOMS= 2,940 / 1,000 = 2.94 X 30 ADT = 88.2 ADT CREDIT PER CARLSBAD MUNICIPAL CODE VOLUME l: CHAPTER 4.E.: BUILDING DEPT. INFO. BUILDING PROJECT ADDRESS, 3135-55 TYLER STREET OF CARLSBAD, CA 92008 LEGAL DESCRIPTION, THE NORTHEASTERLY 140.00 FEET OF LOT 2 OF INDUSTRIAL TRACT, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO.1743 FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, JANUARY 23, 1923. APN, 204-010-03-00 -204-010-04-00 CONSTRUCTION TYPE, TYPE ill-8, NON-SPRINKLERED OCCUPANCY TYPE (PER 2016 CBC), F-1 (MODERATE HAZARD. FACTORY) PRODUCTION FURNITURE MAKING WITH RETAIL SCOPE OF WORK, 1) THE CUP PERMIT REQUEST CONSISTS OF CONVERTING THE SPACE TO MEET THE REQUESTED 'USE" ONLY. NO BUILDING MODIFICATIONS ARE BEING REQUESTED AT THIS TIME AND THE TENANT WOULD LIKE TO USE THE SPACE "AS-iS". 2) UPGRADES CONSISTS OF, A) NEW SIGNAGE FOR COMPANY NAME AND LOGO B) RELOCATING RECYCLE/TRASH RECEPTACLES PER APPROVED LETTER 3) NO NEW ADDED BUILDING SQUARE FOOTAGE IS PROPOSED FOR THIS SCOPE OF WORK. C1 ....,,-CARLSBAD Administrative Permit C,;e No. C..up -Zo2.o -C:,oo'-f ExibitNo. A-l) Date -, Is /z,,.,z.o BUILDING DESCRIPTIONS/ PROJECT AREAS, PRODUCTION AREA EXISTING BUILDING SF, 2940 SQ. FT. (INTERIOR) NOTE, All SF IS CALCULATED TO INT WALLS OF TENANT SPACE ZONE, PINE-TYLER MIXED-USE (PT) SETBACKS FRONT YARD, 5 ft. FRONT YARD LANDSCAPE (PARKING AREA) 10 It SIDE YARD INTERIOR, 0 It. SIDE YARD EXTERIOR, 0 It. REAR YARD (COMMERCIAL USE), 10 ft. HEIGHT, 35 FT MAX. BUILDING CODES• 2016 CALIFORNIA BUILDING CODES, THIS PROJECT SHALL COMPLY WITH, THE 2016 CALIFORNIA BUILDING CODE THc 2016 CALIFORNIA FIRE CODE THE 2016 CALIFORNIA ELECTRICAL CODE THE 2016 CALIFORNIA PLUMBING CODE THE 2016 CALIFORNIA MECHICAL CODE THE 2016 GREEN BUILDING STANDARDS CODE THE 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) THE CURRENT CITY OF CARLSBAD MUNICIPAL CODE PROJECT # CUP 2020-00 V, z 0 z -0 V, i= -"= > "' ~ u "' V, w 0 ~ 0 "" 2 >-V, 17215 Rockhouse Rd. Ramona, CA 92065 y;_,.W.--~ P, 619.944.4810 F: Save poper ... pleose scan and send to email. E: brian@bhgdesigns.net 0 -Q :) ... rn f- UJ w UJ w 0:::: a: f- Cl) m w 0:::: UJ rn _j ~ w f- f-..I L() w ..I L() w ' I ~ L() : i.J.J VJ (") . -' f-w i= _J '<""" (") CJ f- cc f-I U) PROJECT LOCATION, >< w 0 z f-w w I VJ >-' Cl-". 0 f-u w Cl-". ·-· 0 -CL <( 2: >-f- z -u > 3135-55 TYLER STREET CARLSBAD, CALIFORNIA 92008 PROJECT NO, 20-03 0ATE: 19 MAY 2020 INDUSTRIAL PROPERTY: l EDU/ 5,000 SQUARE FEET PRODUCTION/FABRICATION AREA= 2,940 / 5,000 = .588 EDU TERM s AN D C D N D IT I D N s DRAWN BY BHG 1------------------------tCHECKED BY, BHG BHG Designs reserves copyright and ownership of all drawings, design, notes, ideas, and APPROVED BY: __ SUMMARY OF ADT: 12 -88 (CREDIT) = -7 6 ADT (CREDIT) TOTAL= .588 = .59 EDU concepts produced under this Agreement. The same shall not be reproduced, changed or copied in any manner or form whatsoever, nor are they to be assigned to any third party without the written consent of the Designer. Owner may not sell nor assign plans or specifications. SHEET 07 OF 04 Tl TENANT/APPLICANT CONTACT KYLLE SEBREE STUDIO Contact: Kylie Sebree 3500 Roosevelt Street, Unit B Carlsbad, CA 92008 Phone: 760.274.4245 Email: Kyllesebree@gmail.com BUILDING PROJECT ADDRESS: 3135-55 TYLER 51 REET CARLSBAD, CA 9200B APN: 204-010-03-00 AND 204-010-04-00 (PER TITLE REPORT APN'S ARE ADDRESSED A5 ONE LEGAL LOT) UTILITY/ SERVICE DISTRICTS WATER: CARLSBAD MUNICIPAL WATER DISTRICT (760.438.2722) SEWER: CITY OF CARLSBAD WASTEWATER D!VIS!ON {760.438.2722) SCHOOL CARLSBAD UNIFIED SCHOOL DISTRICT (7 60.331.5000) AREA CALC EXISTING TOW COMPANY: I ,625 SQ. FT. VACANT SUITE: 1,580 SQ. FT. PROPOSED BUILDING AREA FOR TENANT IMPROVEMENT: 2,940 SQ. FT. (INT. 8" CMU WALLS/ COLUMNS AND OCCUPANCY SEPARATION: 80 SQ. FT. TOTAL BUILDING AREA: 6,225 SQ FT. PARKING CALC PROPOSED FURNITURE MAKING: PRODUCTION: 2,940/415 =CZ) EXISTING TOW COMPANY 1,625 AT 1/415 =@) VACANT SUITE: 1,580 AT ½is=@) TOTAL REQUIRED =@PARKING TOTAL PROVIDED = @PARKING . SITE LEGEND SYMBOL SYMBOL DEFINITION ---If_ · PROPERTY LINE -----SETBACK CENTERLINE ROAD AREA OF EXTENT FOR SCOPE OF WORK OF SINGLE STORY DIRECTION OF TRAFFIC FLOW INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN CROSSWALK AREA AND/OR NO PARKING AREA PLANTER BOXES FOR LANDSCAPE BUFFERING i Qu'_ -' 0 0, ..,. ,.. :r: 0 o2 ...-----.... --' -ll.J 0.... " 06 (.') u"' z V) 0 V) _J ::r: :=i f-co LL I (.') 0 z f- f-Cr'. -<( V) X 0.... ll.J f- 0 z - fr/ a, !' ~ "' { \ 6 z ~t:; ~~ ~Q ~0 I ::, es o <~ -I "'-~ \ EXISTING RESTKOOM EXISTING RESTROOM ~ a, - ~ C/ CJ N X "' 2'. ~ ~ u ;1 ~ 0 z Q "' < ~ "' ::i 0 ~ " I l1oJ 15'-6'" (El WAd0NP..Y [El PARK!I\G STALLS (ADJACENT PROPERTY) (E) PARKING STALLS {ADJACi:NT PROPERTY) (E) PAR:<ING STALLS [ADJACENT PROPERTY) (E) 0ARKiNG STALLS (ADJACENT PROPERTY) (E) PARr<ING STALLS [ADJAC:'NT PROPERT'-1 (E) PARKII\G STALLS (ADJACENT PR.OPER'f'1 9 CJ N C) 6 \-s V, ~ u <( V, ~ {j 9 ZCJ QN oc X <( C ~ -0 <{ co 0 ~ -0 ! L (E) CURB GUTTER (E) 6' HIGH CHAIN LINK FENCE t TRASH BIi\: #1 117'-0" APN: 204-0 l 0-03-00 AND APN: 204-010-04-00 ROPER Y LINE 58.50' 13 58'-6" TOTAL BLDG SQ.FT. 6225 SQ.FT. / .,"' •• ' 7 '"'"'' ,,, PR.0PERTY LI NE1S8;:so 1 '~ l ;'.;{''' ,,_;,···.,,_,Ir:·,,/. / I/ )/ APN: 204-01 0-1 6-00 (E) GAS METER PROPERTY Ll~<JE 88. 90' -,<- ' ! .• -------.· ------,:__.J___ ~-----',· .. ------------• ' ----- A-1 .TOWING ' NO WORK J....C-...f.-..i...-i.....-1.--J~TRASH ENCLOSURE SHALL BE 1/ I ,( I . I I 0'-0" S.Y.S.B. SETBACK :,. 5'-0" k K 7 1 2 3 4 9'-6" I (7'-0" MIN.) f 6 Mil\. STRIPING WI0TI-: PARKH'<G 20-0' 8 9 10 l l 12 ENCLOSED BY 6FT HIGH MASONRY WALL WiTH GATES PE~ CITY STANDARDS AND MI\J. DEH REQ. CURRE:1\-:-L".' WASTE MANAGEMENT HAS EXISTING TENANTS/OWNERS ROLL-OUT 311\ SERV:c:: THROUGHOUT 24'-0" [24'-0" MIN.) CJ cc 0-- 4- C I :1 12" HIGH LITTERING 1'. i[E) ASPHALT PAVED AREA (NO 18'-0" ,(E) COILING I DOOR 14 I 20'-0" ~ (MIN.) 1 I 15 EXISTING POST (E) COILING oq.o, 6 (E) COILING 23,_0,, ---,1'~f!-. DOOR ··• 20'-0" MIN. 'I' .· MODIFICATl:ONS) STRl?ING :"OR DRIVEWAY GUIDP.NCE STR;PING FOR DRIVEWAYl EXISTING FENCII\G 50'-0" VACANT SUJTE I 0'-0" S.Y.S,B i SETBACK I I I I I I (E)BLDG. 0'-0" ~ .. SETBACK f\ '',;;,: :;:+;· ;:;;·; ;:,;;-, ,, "' 3067 SQ.FT. [EXTERIOR DIM.) 2940 SQ.FT. (INTERIOR DIM.) U..::'.1 ,Z _J >-~ w 0.... 0 ,~I .. ~L ,~,;;_,;:r,,, I I I '. (E) SUCCU~ENT CAFE SUATE B&C (E) ELECTRICAL METER ' ,· / (E).tLECTRICAL POL.E'/ EXISTING BU!l..DING -SUIT&A (NOT PARJOF THIS SCOPE) 'U_! I .:...•-------,,-'-------~------...,.•'--'-_..L'---' (E) 6'-0" HIGH r WOOD FENCE ............ ' ................... -.. """"" """""'"""" """ -_,. .......... -" -. . . ....... "-··· I NOT A PART OF SCOPE '~ .· .. / ( i / ~~ !Ef 6FT ~,1:;::;::::::<IPING AREA I FOR SDGE LINE/POLES AND WIRES I (BOOK 4402: PAGE 30 + BOOK : 4475:PAGi: 308) ·~~ [E) 1 ECTRIU\2 3 /'./ I METRAl:'<DSUPLY · I PbR SDGE LETT~R pN FILE: SDGE s ALL HAVE Ui'.RE~±ICTED 0. N·SITE :./ JccESS TO TGrr,'POLE AND METER Wl'Th 3FT OF CLE!'\RANCE 4 5 / C:OMPACT 6 GUIDANCE \ I r, il.f,ODULAR PLA' 7ERS OR SCREENS ARE AL~OWED WIT :IN T:--!E AREA. ffil (E) AS?HALT PAV _ o ~ AREA [NO ~ U I IL,TY AREA .,.., _ ~ MODiF:CATIONS) ! • I I ~ (E} ¾• WATER METER; TO REMAIN. MAINTAIN MIN. CLEARANCES FOR (:)WATER METER LOCATION. 1 EXISTING EXISTING · • crit EXISTING EXIST:NG ~I PARKING PARKING , "'. , COMPACT PARKING 19 20 "'► ! 21 2 , .. . . -p OPERTY JNE 5 ' -· I ;-. c• "! ~(E) GUTTER (E) CURB & GUTTER ---,, ----- (E) 6'-0" HIGH CHAINLINK FENCE (E) FIRE HYDRANT ~ (E) ELECTRICAL POLE ~ (E) SLIDING GATE \ (E) 4" SEWER LATERAL (E) DRIVEWAY j --Cf: ,/" {E) 6" SEWERLATERAL MAIN AT STREET (PER DWG 118-9, SHEETS-8 & 19) --5-l ~ (C) 6' CITY SEWER MAIN -C~NT:RLINE ~F TRAVEL , j ~, -5---S-·-·-·-·-·S-·-~ TYLER ST J_ s-J,1-6",CIJVSEWEfMAIN , -5--, _ , _ --5 _ , _ s--'\ ~ ~ LAN~S ~ -W·--W· [E) 6' WATER MAii\ -e--w-- APN PARCEL 204-010-03-00 AND 204-010-04-00 (CONSIDERED ONE LOT PER. TITLE K.EPORT) -W-· _ ------f J_E)~" WATER LATERAL MAIN AT STREET (PER DWG 217-9, SHEET~)_ ___ ,t \_ -W--w {E)6W~MAJN_ ~ APN PARCEL 204-010-16-00 NOT A PART Of SCOPE I . ' I I I 5-0 I ; i I I I I I I ! /I I I I I -': p ' Ir. I ol 0 0 --st" /I I .LI ::i.... •<{ ..) .· .n '.J z <( __, .:U-.~ ::,,:: _J -<( 3: ll.J 0 V) 40'-0" w :) z w ' (E) CURB ~ ~ <( I (.') z ::,,:: Cr'. ~ f- ll.J ll.J Q'.'. f- V) LL LL 0 0 (E) 6'-0" HIGH CHAINLINK FENCE (E) ELECTRICAL P (E) SIGN TO REMAIN PROJECT # CUP 2020-00 0.: w °' ~ 17215 Rockhouse Rd. Romona, CA 92065 y;_,..H:"~ P: 619.944.4810 F: Save paper ... pleose scan and send to email. E: brian@bhgdesigns.net 0 -Q ::, I-u, I-w w w w 0::: a:: f- (J) z m 0::: -<( w _J w Q_ 0 ___J w >-f- w I-U) ...I LO _J ..I LO _J I -<( > LO w ct: (") ~ r c= w ~ ..-> (") ,.. G 0 LJ :c (f) PROJECT LOCATION: 3 I 35-55 TYLER STREET CARLSBAD, CALIFORNIA 92008 C? EXIS7ING BUILDING RE-USE TENANT IMPROVEMENT +----",~.,-----;d;ot-------\;=============================~ WiTH PROPOSED PATIO AT FRONTYARDANDS:OE PROJcCT NO: 20-03 9 ~ ~ BUiLNIG AND PROPOSED PA~KING RESTRIPE tr) u ~ OCCUPANCY CLASS PER 2016 CBC PROPOSED TENANT IMPROVEMENT: TYPE F-1 / FURNITURE MAKER EXISTING ADJACENT: VACANT EXISTING WEST TENANT: OVERALL SITEPLAN PLAN NORTH llrTI PREVIOUS TENANT SPACE: A I-TOWING, TYPE F-1 TYPE A-3 ASSEMBLY/FITNESS GYM (2,805 SQ.FT. EXCLUDING RESTROOMS) TRUE NORTH GRAPHIC SCALE { IN FEET ) 1inch=1D :rt. T DATE: 19 MAY 2020 TERMS AND CONDITIONS DRAWN BY BHG 1---------------------------IICHECKED BY: BHG BHG Designs reserves copyright and ownership of all drawings, design, notes, ideas, and APPROVED BY: __ concepts produced under this Agreement. The same shall not be reproduced, changed or copied in any manner or form whatsoever, nor are they to be assigned to any third party without the written consent of the Designer. Owner may not sell nor assign plans or specifications. SHEET 02 OF 04 SP1 UP +0'-0" ' EXISTING 8" MASONRY BLOCK WALL CONSTRUCTION. TYPICAL AT ALL CQ EXTERIOR WALLS. 6 0 N EXISTING SERVICE RAMP; TO RE/IA.A.IN ~ (E) SERVICE RAMP lANDING AND STEPS; TO REMAIN . ' I' . :s 'o 0 -' 0 0 ('.) z f-a, @ Cl z z w 0.. 0 .. g I~ 'W Q_ 0 l 0'-8" CD ~ ADjACENT TENANT J SPACE NOT PART OF THIS SCOPE 48'-8" 4 7'-6" VERIFY IN FIELD FOK EXISTING WALL TO MEET MIN. 2-HR FIRE RATING FOK OCCUPANCY SEPARATION ~ EXISTING CONCRETE ~ ScAB ON GRADE; TYP. ',). FURNITURE MAKING/ PRODUCTION AREA OPEN ROOM ~ EXISTING ~ON':RETE ~ S:..A3 ON uRAD~; TYP. '::J_ NO PROPOSED BLDG. MODIFICATIONS OR SITE MODIFICATIONS. CUP PERMIT REQUESTED FOR "PROPOSED USE" ONLY. ~ EXISTING CONCRETE ~ SLAB or--.· GRA:)E; TYP. ~ EXISTING OUTSWING DOORS 5'-i" 18" " 93" I-4 n e --.....__' / RESfROOM \ SINGLE ACC0M. L\ 1 UNISEX ~ '-..___ ADJACENT TENANT SPACE NOT PART OF THIS SCOPE ALL STRUCTURAL MASONRY COLUMNS SHALL REMAIN. TYP. A:..L STRUCTURAL M/lSONRY COLUMNS SHALL REMAIN. TYP. EXISTING WINDOW I i t JC~~~~~~~3l:====~:;~= ~=-=~== ~= ~=~ -----'k---------------'ls-EXISTING WINDOW EXISTING 4"-8" 8'-l~" i 5'-l~" 8'-0·' 48'-8' (INTERIOR CMU WALL) 50'-0" (EXTERIOR CMU WALL) FLOOR PLAN -EXISTING (NO PROPOSED WORK) 12'-l" 0 0 ELECTRICAL METER AND SUPPLY 0 EXISTING FENCC LOCATION PlAN NORTH 0 0 V IJm l ' T:1UE NORTH SCALE I 3' l O' 15' 5' l/4" = l '-0" (l : 48) PROJECT # CUP 2020-00 V, z ' 0 I V, > w ~ 0.: w "' ' Q_ z 0 e= Q_ i2 u V, w 0 l 7215 Rockhouse Rd. Ramona, CA 92065 3S:-t~ P: 619.944.4810 F: Save poper ... please scan and send to email. E: brian@bhgdesigns.net 0 -Q :::, I- ti) f-w w w w 0::: ~ f- m Cl) 0::: w w ti) ....J >-w f- -I I.() ..J I.() I > I.() Cl) ~ ...--- Cl) w -" f-i= tc w I U1 ,,--__ c,:'.'. O:'. 0 s 0 w (.fJ 0 Q_ 0 O:'. O_ 0 z '---./ C) z f-- (./J X w z <C ____J Q_ O:'. 0 0 ____J LL PRO~ECT LOCATION: 3135-55 TYLER STREET CARLSBAD, CALIFORNIA 92008 PROJECT NO: 20-03 DATE: 19 MAY 2020 TERMS AND CON DITIDNS DRAWN BY BHG 1--------------------::-----,----,--;------,------;-1 CHEC~ED BY: BH G BHG Designs reserves copyright and ownership of all drawings, design, notes, ideas, and APPROVED BY: __ concepts produced under this Agreement. The same shall not be reproduced, changed or copied in any manner or form whatsoever, nor are they to be assigned to any third party without the written consent of the Designer. Owner may not sell nor assign plans or specifications. SHEET 03 OF 04 A1 ~ Nu PROPOSED BLDG. MODIFICATIONS OR SITE ~ ✓ MODIFICATIONS. PERMIT REQUESTED FOR ~ "PROPOSED USE" ONLY. :JRIVEWAY 23'-2' ~ $ CEILING HEIGHT N 9 0 N Kylie Sebree ·.· ··r<>~ J:. f.o'· >.i·· .o.:< I .. ····•·· •· •••· .. ··.· ,· .··• .·, ·· ... ·· .• ··· .. ·•· ... · ··. . · ... · .. -... · .. · ... .·. ·.. ·,. · ........... · .. · .. · .. ··.· ·• .. •.• .. · • ... • .. ··· .. ·. ·-.·• 1 _ __J --,-" ~_c _ ~ ~ _ ~ ~ ___________ -~-E~T:;~~~~:'~~~;;~ ~ ______ _ . I ,, ,; ' ' .:! J,; / "" ,, EXISTING NEW PROPOSED S!GN./-GE, TOTAL AREA NOT TO EXG:EED 50 SQ. FT. WITH TEXT HEIGHT 18" OR LESS PER VILLAGE MASTER PLAN. I ~!STING CMU BLOCK WALL; lYFICAL AT ALL LOCATIONS. NO PROPOSED MODIF!CA.TIONS. 6'-0" dsTJNG METAL ROOF; BEYON I I I ..___.-,::-~I I 6FT SDGE EASEMENT. MODULAR PLANTERS AND SCREENING ALLOWED PER SDGE LETTER ON F!LE. I . --· ·2 ~ · .· ·. ·: .;·...: ,'. ·:->--,:·J__ ·-·< · .. I ;_~~~~+----~ EXISTING GALVANIZED CONDUIT kf PIPE AND WIRE PER SDGE LINES. . ·. ·. :-. ·. , .. ·.--..;.. . '· I - I .· I . EXISTING SCUPPER AND DOWNSPOUT TO REMAIN. EXISTING EL:.:CTRICAL SDGE VAULT SHAC.L MAINTAIN MIN. ACCESS CEARANCES ~ EX:STING ASPHALT PAVING AREA; TO REMAIN. ~ TING GUTTER) ' ~ EXISTING ASPHALT PAVING AREA; TO REMAIN. ~ (SLOPES TO EXISTING GUTTER) -+--------(E) DRIVEWAY GATE ENTRANCE------------~,__ NO MODIFICATION 4S-8"(1~~U) ~ 50'-0" (EXTERIOR) : -++---------------------------------------~-+-----------------------~--------+~ PROPrnTYc!NE I (E) FENCE TO PROPERTY LINE AND EXISTING SLIDER GATE; TO REMAIN. NO PROPOSED BLDG. MODIFICATIONS OR SITE MODIFICATIONS. PERMIT REQUESTED FOR "PROPOSED USE" ONLY. $ CEILING HE!GHT MAXIMUM '.:XISTING GxADE CHANGE FROM FINSH FLOOR TO STEM WALL. CEili NG HEIGHT PROPERTY LINE PER SITEPLAI\ I 1. I, I I I b 6 N !i !,, EXISTING PIPE STffL FRAMED AWNING WITH EXTERIOR GRADE-FABRIC. 51-011 CITY PLANTER RIGHT-OF-WAY 5'-0" 14'-10" 15'-6' I l .1 I I I I I I EXISTING ASPHALT GRADE/SLO;:iE VARIES AWAY 'ROM 3LDG. AT PJ\1[)0T ~XISTING CMU BLOCK FACADE (E) FENCE TO PROPERTY c!NE AND EXISTiNG SLIDER GATE; TO REMAIN. EXISTING METAL ROOF TO REMAIN EXISTING EXTEi<IOR FRENCH DOORS; TO REMAIN. I I , h I· 11 'I ,. I I ' I I Ii !! Ii j\ I' ., / lj ' 'i l I I ' I ! i I I I :I 'I I I I . . . I I r -> .: ..... ·. •· ·•. < ··,·.: . < ·•··.. . ..... .· .•... · .... ·.· .... •·· .·. · ... · .. ·.• ·.. • . •.·· . . < ·,-·. . .· ·· .... · .. • _· ... • i .· .· .. ·.· -·· .· ·· .. · .. . .· ... ·• ... ·.· .. · < ; •·• . ·• .· ... •.. • • • •-• • . •· · .. ··. · .. :·.· ....... ·... •. ·. I -I 1.· ..... •·· 1::. . .. I -· . I . ! I . i I I I I I I I EX!STING EDGE OF INTERIOR WALL AT OCCUPANCY SEPARATION : •. .· ·... < .. ··... .. ··.·.. . . .· ....• · .. ·, ·. i•. •· .•. •. ·.·· .. •.··.. . . •. ··· .·.· .... · .. ·.• • .• . • • .. .... . _:_. .__._ i ..•...• -.__._ ~ .• ·.•• ·. •·· . · .. ,· •.· ... ·•·· .· . . ... · . . .. · .... · i. ·.· ·~ .· > . .· ......... · · ... · .. ·., .... •· .·· · .. · .• · ... .__._. . .· -.· .· •.. ·.. . . -~ < . ·. ··. ..· .. · ....... ·• i J -- NO WORK AT EXTERIOR EXISTING METAL ,OOF TO REMAIN :1 ' . \.. ENTR'/Y(: I i :I ,, i I i I l . I le---~ i I I . EXISTING CMU BLOCK FACADE EXISTING PIPE STEEL FRAMED AWNING WITH EXTERIOR GRADE-FABRIC. (E) BACKFLOW PREVENTION TO REMAIN AND TO ALLOW ACCESS F,OM OJTSIDE OF PATIO AREA l S' 0 N NO PROPOSED BLDG. MODIFICATIONS OR SITE MODIFICATIONS. PERMiT REQUESTED FOR 'PROPOSED USE" ONLY. PROPER.1Y LINE PER. SITE?LAN PROJECT # CUP 2020-00 V, z 0 z 0 V, F CL > o2 ~ u ~ V, ~ 0 ~ 0 CD ::,: >-V, 17215 Rockhouse Rd. Ramona, CA 92065 y;.,.~~ P, 619.944.4810 F: Save paper ... please scan and send to email. E: brian@bhgdesigns.net 0 -Q ::, I-,n f- .W w w w 0:::: (J) a:: f-z 0 m Cl) f-0:::: w <( w > ,n ....J w >-_J w f-w ..I LC') O::'. ..I LC') 0 I O::'. > LC') w C") ~ w c->= f-~ ,..... C") w X w w :r: rn PROcECT LOCATION• 3135-55 1YLER STREET CARLSBAD, CALIFORNIA 92008 PROJECT NO, 20-03 DATE: 7 9 MAY 2020 -' $FINISHED fLOOR LEVEL J! TERMS AND CON DITl □NS DRAWN BY BHG 1-----------------------------11 CHECKED BY, BHG BHG Designs reserves copyright and ownership of all drawings, design, notes, ideas, and APPROVED BY: __ .-,J ASPrlALT FINISHED PA~.K!NG GRAUE VARIES 1, EDGE OF EXISTING ADJACENT BUILDING. AND TERMINATION OF T~NANT SPACE. EXISTING EXTERIOR CMU 3!...0CK WAL'5-i. TYPICAL AT ALL LOCATIONS. NO MODIFICATIONS. 61 '-4" L EXISTING CONC. RAMP; TO REMAIN_ EXlSTiNG METAL ROL~-UP DOOR TO REMAIN. S!GNAGE PER CALSBAD ViLLAGE MUNICIPAL CODE. EXISTING ENTRY/EXIT oom EX!STING STEPS AND LANDING TO REMAIN. EXISTING ASPHALT GRADE/SLOPE VARIES AWAY FROM BLDG. AT FRONT 5'-0·' F.YS.B. 5'-0" Cl1Y PLANTER RIGHT-Of-WAY concepts produced under this Agreement. The same shall not be reproduced, changed or copied in any manner or form whatsoever, nor are they to be assigned to any third party without the -written consent of the Designer. Owner may not sell nor assign plans or specifications. SHEET 04 OF 04 A2