Loading...
HomeMy WebLinkAbout6170 INNOVATION WAY; ; AS080026; Permit1/30/23, 4:58 PM AS080026 Permit Data about:blank 1/1 City of Carlsbad Sprinkler Permit Permit No:AS080026 Job Address:6170 INNOVATION WY Status:ISSUED Permit Type:SPRINK Applied 2/26/2008 Parcel No:2132621000 Approved:2/26/2008 Lot #:0 Reference No.:Issued:2/26/2008 PC #:Inspector: Project Title:SALVAGIO TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant:Owner: INDUSTRIAL FIRE SPRINKLER CO., 3845 IMPERIAL AV SAN DIEGO CA 619-266-6030 ---------- PALOMAR AIRPORT ROAD LLC 9171 TOWNE CENTRE DR #460 SAN DIEGO CA ---------- Fees ($)Add'l Fees ($)Total ($)Balance ($) 130 0 130 0 Oct-29-2007 09:47 AM CityofCarlsbad Fire Prevention 602-8561 ~ A 5080020 CARLSBAD FIRE PREVENTION DIVISION Permit Applic~tion FQrm A. Check or fill in pertinent infonnation for type of permit you are submitting. AS-Automatic Sprinklers (Clieck off type of plans being submitted) __ New System -How many risers/levels? __ X Tenant Improvement __ Residential -How many systems and/or buildings? __ __ Underground for approval __ :Underground included for reference only FA -Fire Alarm 25 Devices or less ---Over 26 devices # of devices __ _ Monitoring System FS -Fixed Systems (Circle One) Hood & Duct, Special Chemical Agent Suppression System, Standpipe, Spray Booth or Appliance. Failed Inspection fee Is $65.00. Total Fees '!:>i/ 3 0 ~ Total Fees __ _ Total Fees ___ _ B. Name of Project: .5· ~ L \/' A \):-..; C) /., I., Jo k? ~ ~ e X>I\Q._-:> or <e,no C. Address of job site: ...k+tg: ;!. J)J N Q VIT 1 O 14 \:<?A,-,, . I f Suite# ___ _ Building Permit# CB ~ C &ob :3 b GS- o 1 ii D. Contractor Information :PJJlp 7~ . Address 3YS <f ) ,.L M 9 ~Q-..0~ L. A lJ ;,, City S:A H ~ J ~ o Smte ~ Zip'j.l-, 1 3 Phone (bl'jj £_,<,,,~,..~o 3o Fax (i,1i) ~~,., ,.602:,S 3/3 Kind of License and Number F,2..t,, :S ,'•gJ ,_.k U c_1<,,-S:5':ilo ~ LJ Exp. Dated-~1,~ --c9 ~ ~ Do you currently have a business license on file with the City of Carlsbad? @ or No / 2 o (,, r; 2-( ~ Signature d-(,%.L / Date ¥2-tb( I lPlease estimate at least 10 business days for plan review comments and/or approval. We will contact you by telephone when the plans are mpproved/disappiroved. Tb.ank you! '+-( 3v/og I J u Plan Review Requirements Category: SPRINK , TI Date of Report: 03-11-2008 Name: Address: INDUSTRIAL FIRE SPRINKLER CO., 3845 IMPERIAL AV SAN DIEGO CA 92113 Permit #: AS080026 Job Name: SALVAGIO Job Address: 6170 INNOVATION WY CBAD Reviewed by: ~ IHC6i\lPL1!:'fl!: The item you hue o aaefltitteti io, 18, iow is-iM:1:Hnitpl8t0 1 t thii tim.-, thic e~ci sarret adoqttn1el, eennuet a 10 e ic .. to dctcnninc conrpiiancc ce Hh Mm applicabk codes and/bl Stdliddld§. Fl6£e review -•rafitl15 811 @OMfflCHts attadtcd. Please tcsabnrit etm necessaty ptans aiiWdf specificauons, wnh changes "ciouded", to thio ofii:00 in rouiour lift8 iflfJH 0si Conditions: Cond: CON0002655 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 03/11/2008 By: CWONG Action: AP TO ATT STREET CITY PHONE INDUSTRIAL FIRE SPRINKLER CO., INC. 3845 IMPERIAL AVE., SAN DIEGO, CA, 92113 C-16 558084 Phone (619) 266-6030 Fax (619) 266-6035 Carlsbad Fire Dept. 2560 Orion Way Carlsbad STATE CA. I ZIP I 92010 1-760-931-FAX 2141 GENTLEMEN: WE ARE SENDING YOU { 181 HEREWITH 0 UNDER SEPARATE COVER VIA 0 PREUM. ORA WINGS 181 PRINTS 0 APPROVED PLANS DATE 2/22/08 I JOB# I 08-600 JOB .Salvagio T .I Towers at Bressi Ranch Lots 24-28 &t~~- STREET 61.Jk1nnov~ti~n Way CITY Carlsbad STATE CA I ZIP I 92009 PHONE FAX .. } THE FOLLOWING ITEMS: 0 SAMPLES 181 MATERIAL CUT SHEETS 0 CALCULATIONS 0 SAFETY DATA SHEETS 0 COPY OF LETTER 0 OTHER: QUANTITY SHEETS DESCRIPTION 3 2 Fire sprinkler T .I. plans 1 2 Material cut sheets 1 1 Check in the amount of $130.00 THESE ARE TRANSMITTED: 181 FOR APPROVAL 0 FOR YOUR USE 0 AS REQUESTED 0 DISTRIBUTION TO ARCHITECT O DISTRIBUTION TO MEP TRADES 0 FOR REVIEW AND COMMENT 0 OTHER REMARKS: CC: FROM: Ste SIGNED: ---.,l-~-#---__,,,.~:::;__-1------.-------- . ER THAN INDICATED, OFFICE AT ONCE. Lo .... -.···s.·-··.E···· ................ . . . ( ' . . : ·:,' .. · .. ' -.: . f'IRIJSPIIINKLER CORPORATION QUICK RESPONSE AUTOMATIC SPRINKLERS GLSERIES DESCRIPTION AND OPERATION UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount offluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings-135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141 °C). • WaterWorking Pressure Rating-175 psi (12 Bars). • Factory tested hydrostaticallyto500psi (34 Bars). • Maximum low temperature glass bulb rating is-67°F (-55°C). • Frame -bronze • Deflector -brass • Screw -brass • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb-glass with alcohol based solution, 3mm size. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION ORDINARY INTERMEDIATE HIGH AVAILABLE SPRINKLER TEMPERATURES 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 DECEMBER 2006 A-20 BULB COLOR ORANGE/RED BLUE N.F.P.A. MAXIMUM CEILING TEMPERATURE 989-846-4583 • FAX 989-846-9231 BULLETIN GL5615, REV. #6 QUICK-RESPONSE AUTOMATIC SPRINKLERS GLSERIES UPRIGHT• PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH 1 FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1 HORIZONTAL SIDEWALL IS 2 9/16". STYLE SIN K 135°F 155°F MODEL FACTOR s1°c 68°C GL2815 2.8 X X GL4215 4.2 X X UPRIGHT GL5615 5.6 X X GL8115 7.8* X X GL8118 8.1 X X GL2801 2.8 X X GL4201 4.2 X X PENDENT GL5601 5.6 X X GL8101 7.8* X X GL8106 8.1 X X VERTICAL GL5632 5.6 X X SIDEWALL GL8133 8.1 X X GL2826 2.8 X X HORIZONTAL GL4226 4.2 X X SIDEWALL§ GL5626 5.6 X X GL8127 8.1 X X CONVENTIONAL GL5624 5.6 X X (OLD STYLE) GL8125 8.1 X X 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. 175°F 200°F 286°F NYC -DOB 79°c 93°c 141°c cULus F.M. LPC CE MEA 101-92-E X X X X ---X X X X X ----X X X X X X X X X X X X X X ----X X X X X X X X X X X X X ----X X X X X ----X X X X X X X X X X X X X X --X X X X X X X X X X X X X X ---- X X X X ---- X X X X ---X X X X X -----X X X X X X ---X X X X X ---- X X X --X X - X X X --X X - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity -Wrenches -P/N 325390 (1/2"); P/N 312366 (L.O.) LOBE. FIRE SPRINKLER CORPORATION DECEMBER 2006 PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. *1/2" NPT. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #6 QUICK RESPONSE AUTOMATIC SPRINKLERS GLSERIES DESCRIPTION AND OPERATION UPRIGHT• PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount offluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings-135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141 °C). • WaterWorking Pressure Rating-175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34Bars ). • Maximum lowtemperatureglassbulbrating is-67°F (-55°C). • Frame -bronze • Deflector-brass • Screw -brass • Bulb seat -copper • Spring -nickel alloy • Seal -teflon • Bulb-glasswithalcoholbasedsolution, 3mmsize. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION ORDINARY INTERMEDIATE AVAILABLE SPRINKLER TEMPERATURES BULB COLOR ORANGE/RED LLOW/GREEN HIGH BLUE 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 DECEMBER 2006 A-20 N.F.P.A. MAXIMUM CEILING TEMPERATURE 989-846-4583 • FAX 989-846-9231 BULLETIN GL5615, REV. #6 QUICK RESPONSE AUTOMATIC SPRINKLERS GLSERIES UPRIGHT• PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH 1 FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1 HORIZONTAL SIDEWALL IS 2 9/16". STYLE SIN K 135°F 155°F MODEL FACTOR s1°c 68°C GL2815 2.8 X X GL4215 4.2 X X UPRIGHT GL5615 5.6 X X GL8115 7.8* X X GL8118 8.1 X X GL2801 2.8 X X GL4201 4.2 X X PENDENT GL5601 5.6 X X GL8101 7.8* X X GL8106 8.1 X X VERTICAL GL5632 5.6 X X SIDEWALL GL8133 8.1 X X GL2826 2.8 X X HORIZONTAL GL4226 4.2 X X SIDEWALL§ GL5626 5.6 X X GL8127 8.1 X X CONVENTIONAL GL5624 5.6 X X (OLD STYLE) GL8125 8.1 X X 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. 175°F 200°F 286°F NYC-DOB 19°c 93°c 141°c cULus F.M. LPC CE MEA 101-92-E X X X X ---X X X X X -----X X X X X X X X X X X X X X --X X X X X X X X X X X X X ---X X X X X ---X X X X X X X X X X X X X X --X X X X X X X X X X X X X X --- X X X X ---- X X X X ---X X X X X ---X X X X X X --X X X X X ---- X X X --X X - X X X --X X - § HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity -Wrenches -P/N 325390 (1/2"); P/N 312366 (LO.) LOBE. FIRE SPRINKLER CORPORATION DECEMBER 2006 PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. *1/2" NPT. GLOBE8) PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL5615, REV. #6