Loading...
HomeMy WebLinkAboutSDP 2021-0016; CARLSBAD OAKS NORTH, LOT 3; PRELIMINARY STORM WATER QUALITY MANAGEMENT PLAN; 2021-12-06•, '' CITY OF CARLSBAD PRIORITY DEVELOPMENT PROJECT (PDP) PRELIMINARY STORM WATER QUALITY MANAGEMENT PLAN, r f f~ (SWQMP) FOR Lot 3, Whiptail Loop FEB O ii 2022 SOP 2021-0016 Cl fY 0;-CARLSBAD NGINEER OF WORK: Danny Abada, P.E. PREPARED FOR: Owner/Subdivider: Tech Contractors c/o Dean Smith 3575 Kenyon St., Suite 200, San Diego, CA 92110 619-223-1663 dean@techbilt.com PREPARED BY: SPEAR & ASSOCIATES, INC. CIVIL ENGINEERING & LAND SURVEYING 475 Production Street San Marcos, CA 92078 Telephone: (760) 736-2040 DATE: 12/6/21 RECORD COPY Initial TABLE OF CONTENTS Certification Page Project Vicinity Map FORM E-34 Storm Water Standard Questionnaire Site Information FORM E-3(;> Standard Project Requirement Checklist Summary of PDP Structural BMPs Attachment 1: Backup for PDP Pollutant Control BMPs Attachment 1 a: OMA Exhibit Attachment 1 b: Tabular Summary of DMAs and Design Capture Volume Calculations Attachment 1 c: Harvest and Use Feasibility Screening (when applicable) Attachment 1d: Categorization of Infiltration Feasibility Condition (when applicable) Attachment 1 e: Pollutant Control BMP Design Worksheets I Calculations Attachment 2: Backup for PDP Hydromodification Control Measures Attachment 2a: Hydromodification Management Exhibit Attachment 2b: Management of Critical Coarse Sediment Yield Areas Attachment 2c: Geomorphic Assessment of Receiving Channels Attachment 2d: Flow Control Facility Design Attachment 3: Structural BMP Maintenance Thresholds and Actions Attachment 4: Single Sheet BMP (SSBMP) Exhibit ( t ( CERTIFICATION PAGE Project Name: Lot 3, Whiptail Loop I hereby declare that I am the Engineer in Responsible Charge of design of storm water BMPs for this project, and that I have exercised responsible charge over the design of the project as defined in Section 6703 of the Business and Professions Code, and that the design is consistent with the requirements of the BMP Design Manual, which is based on the requirements of SDRWQCB Order No. R9-2013-0001 (MS4 Permit) or the current Order. I have read and understand that the City Engineer has adopted minimum requirements for managing urban runoff, including storm water, from land development activities, as described in the BMP Design Manual. I certify that this SWQMP has been completed to the best of my ability and accurately reflects the project being proposed and the applicable source control and site design BMPs proposed to minimize the potentially negative impacts of this project's land development activities on water quality. I understand and acknowledge that the plan check review of this SWQMP by the City Engineer is confined to a review and does not relieve me, as the Engineer in Responsible Charge of design of storm water BMPs for this project, of my responsibilities for project design. Danny Aba?a, P.E. RCE 45381 Expiration 9/30/22 V Spear & Associates Inc. Company 12/6/21 Date PROJECT VICINITY MAP LOCATION MAP (No scale) [Insert City's Storm Water Standard Questionnaire (Form E-34) here] ~ City of Carlsbad STORM WATER STANDARDS QUESTIONNAIRE Development Services Land Development Engineering 1635 Faraday Avenue (760) 602-2750 www.carlsbadca.gov E-34 I INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the city requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMPs) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual, refer to the Engineering Standards (Volume 5). This questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'STANDARD PROJECT' requirements or be subject to 'PRIORITY DEVELOPMENT PROJECT' (PDP) requirements. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the fina l assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you , this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the city. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A completed and signed questionnaire must be submitted with each development project application. Only one completed and signed questionnaire is requ ired when multiple development applications for the same project are submitted concurrently. PROJECT INFORMATION PROJECT NAME: Lot 3, Whiptail Loop PROJECT ID: ADDRESS: Lot 3, Whiptail Loop, Carlsbad, CA 92008 APN: 209-120-02 The project is (check one):~ew Development D Redevelopment The total proposed disturbed area is: 225775 ft2 ( 5.18 ) acres The total proposed newly created and/or replaced impervious area is: 151060 ft2 ( 3.47 ) acres If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the SWQMP # of the larger development project: Project ID SWQMP#: Then , go to Step 1 and follow the instructions. When completed , sign the form at the end and submit this with your application to the city. E-34 Page 1 of 4 REV 02/16 STEP 1 TO BE COMPLETED FOR ALL PROJECTS To determine if your project is a "development project", please answer the following question: YES NO Is your project LIMITED TO routine maintenance activity and/or repair/improvements to an existing building □ ~ or structure that do not alter the size (See Section 1.3 of the BMP Design Manual for guidance)? If you answered "yes" to the above question, provide justification below then go to Step 5, mark the third box stating "my project is not a 'development project' and not subject to the requirements of the BMP manual" and complete applicant information. Justification/discussion: (e.g. the project includes only interior remodels within an existing building): If you answered "no" to the above question, the project is a 'development project', go to Step 2. STEP2 TO BE COMPLETED FOR ALL DEVELOPMENT PROJECTS To determine if your project is exempt from PDP requirements pursuant to MS4 Permit Provision E.3.b.(3), please answer the following questions: Is your project LIMITED to one or more of the following : 1J YES NO 1. Constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet the following criteria: a) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non-~ erodible permeable areas; □ b) Designed and constructed to be hydraulically disconnected from paved streets or roads; c) Designed and constructed with permeable pavements or surfaces in accordance with USEPA Green Streets guidance? 2. Retrofitting or redeveloping existing paved alleys, streets, or roads that are designed and constructed in □ rL" accordance with the USEPA Green Streets guidance? 3. Ground Mounted Solar Array that meets the criteria provided in section 1.4.2 of the BMP manual? □ < If you answered "yes" to one or more of the above questions, provide discussion/justification below, then go to Step 5, mark the second box stating "my project is EXEMPT from PDP ... " and complete applicant information. Discussion to justify exemption ( e.g. the project redeveloping existing road designed and constructed in accordance with the USEPA Green Street guidance): If you answered "no" to the above questions, your project is not exempt from PDP, go to Step 3. 0 E-34 Page 2 of 4 REV 04/1 7 STEP3 C TO BE COMPLETED FOR ALL NEW OR REDEVELOPMENT PROJECTS To determine if your project is a PDP, please answer the following questions (MS4 Permit Provision E.3.b.(1 )): YES NO 1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces collectively over the entire project site? This includes commercial, industrial, residential, mixed-use, .v □ and public development projects on public or private land. 2. Is your project a redevelopment project creating and/or replacing 5,000 square feet or more of impervious surface collectively over the entire project site on an existing site of 10,000 square feet or □ ~ more of impervious surface? This includes commercial, industrial, residential, mixed-use, and public development projects on public or private land. 3. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface collectively over the entire project site and supports a restaurant? A restaurant is ~ a facility that sells prepared foods and drinks for consumption, including stationary lunch counters and □ refreshment stands selling prepared foods and drinks for immediate consumption (Standard Industrial Classification (SIC) code 5812). 4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious ~ surface collectively over the entire project site and supports a hillside development project? A hillside □ development project includes development on any natural slope that is twenty-five percent or greater. 5. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more ~ of impervious surface collectively over the entire project site and supports a parking lot? A parking lot is □ a land area or facility for the temporary parking or storage of motor vehicles used personally for business or for commerce. 6. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more ~ of impervious street, road, highway, freeway or driveway surface collectively over the entire project □ site? A street, road, highway, freeway or driveway is any paved impervious surface used for the transportation of automobiles, trucks, motorcvcles, and other vehicles. C'· 7. Is your project a new or redevelopment project that creates and/or replaces 2,500 square feet or more of impervious surface collectively over the entire site, and discharges directly to an Environmentally ~ Sensitive Area (ESA)? "Discharging Directly to" includes flow that is conveyed overtand a distance of □ 200 feet or less from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the project to the ESA (i.e. not commingled with flows from adjacent lands).* 8. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square ~ feet or more of impervious surface that supports an automotive repair shop? An automotive repair □ shop is a facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013, 5014, 5541, 7532-7534, or 7536-7539. 9. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square ~ feet or more of impervious area that supports a retail gasoline outlet (RGO)? This category includes □ RGO's that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic (ADT) of 100 or more vehicles per day. 10. Is your project a new or redevelopment project that results in the disturbance of one or more acres of land r< □ and are expected to generate pollutants post construction? 11 . Is your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of impervious surface or (2) increases impervious surface on the property by more than 10%? (CMC □ ~ 21 .203.040) If you answered "yes" to one or more of the above questions, your project is a PDP . If your project is a redevelopment project, go to step 4. If your project is a new project, go to step 5, check the first box stating "My project is a PDP ... " and complete applicant information. If you answered "no" to all of the above questions, your project is a 'STANDARD PROJECT.' Go to step 5, check the second box stating "My project is a 'STANDARD PROJECT' ... " and complete aoolicant information. E-34 Page 3 of 4 REV 04/17 STEP4 TO BE COMPLETED FOR REDEVELOPMENT PROJECTS THAT ARE PRIORITY DEVELOPMENT PROJECTS (PDP) ONLY Complete the questions below regarding your redevelopment project (MS4 Permit Provision E.3.b.(2)): YES NO Does the redevelopment project result in the creation or replacement of impervious surface in an amount of less than 50% of the surface area of the previously existing development? Complete the percent impervious calculation below: Existing impervious area (A) = sq. ft. □ □ Total proposed newly created or replaced impervious area (B) = sq . ft. Percent impervious area created or replaced (B/A)*100 = % If you answered "yes", the structural BMPs required for PDP apply only to the creation or replacement of impervious surface and not the entire development. Go to step 5, check the first box stating "My project is a PDP ... " and complete applicant information. If you answered "no," the structural BM P's required for PDP apply to the entire development. Go to step 5, check the check the first box stating "My project is a PDP ... " and complete applicant information. STEPS CHECK THE APPROPRIATE BOX AND COMPLETE APPLICANT INFORMATION My project is a PDP and must comply with PDP stormwater requirements of the BMP Manual. I understand I must prepare a Storm Water Quality Management Plan (SWQMP) for submittal at time of application. 0 My project is a 'STANDARD PROJECT' OR EXEMPT from PDP and must only comply with 'STANDARD PROJECT' stormwater requirements of the BMP Manual. As part of these requirements, I will submit a "Standard Project Requirement Checklist Form E-36' and incorporate low impact development strategies throughout my project. Note: For projects that are close to meeting the PDP threshold, staff may require detailed impervious area calculations and exhibits to verify if 'STANDARD PROJECT' stormwater requirements apply. D My Project is NOT a 'development project' and is not subject to the requirements of the BMP Manual. Applicant Information and Signature Box Applicant Name: Applicant Title: Applicant Signature: Date: • Environmentally Sens1t1ve Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; Habitat Management Plan; and any other equivalent environmentally sensitive areas which have been identified by the City. Th . B ~ C"t U O I IS ox or IW se n1v YES NO City Concurrence: □ □ By: Date: Project ID: E-34 Page 4 of 4 REV 04/17 (_) SITE INFORMATION CHECKLIST Project Summary Information Project Name Lot 3, Whiptail Loop Project ID SOP 2021-0016 Project Address Whiptail Loop, Carlsbad, CA 92008 . Assessor's Parcel Number(s) (APN(s)) 209-120-02 Project Watershed (Hydrologic Unit) Carlsbad 904 Parcel Area 5.18 Acres ( 225,775 Sauare Feet) Existing Impervious Area 0.34 Acres ( 14,700 Square Feet) (subset of Parcel Area) Area to be disturbed by the project 5.18 Acres Square Feet) (Project Area) (225,775 Project Proposed Impervious Area 3.47 Acres (subset of Project Area) (151,060 Square Feet) Project Proposed Pervious Area 1.72 Acres Square Feet) (subset of Project Area) (74,715 Note: Proposed Impervious Area+ Proposed Pervious Area= Area to be Disturbed by the Project. This may be less than the Parcel Area. Description of Existing Site Condition and Drainage Patterns Current Status of the Site (select all that apply): Existing development X Previously graded but not built out □ Agricultural or other non-impervious use □ Vacant, undeveloped/natural Description/ Additional Information: The site includes an existing single family residence. Existing Land Cover Includes (select all that apply): X Vegetative Cover □ Non-Vegetated Pervious Areas □ Impervious Areas Description/ Additional Information: The site is mostly bare and covered with patches of native grass. Underlying Soil belongs to Hydrologic Soil Group (select all that apply): D NRCS Type A NRCS Type B D NRCS Type C X NRCS Type D Approximate Depth to Groundwater (GW): D GW Depth < 5 feet □ 5 feet < GW Depth < 1 0 feet X 1 0 feet < GW Depth < 20 feet GW Depth > 20 feet Existing Natural Hydrologic Features (select all that apply): □ Watercourses □ Seeps □ Springs □ Wetlands X None Description/ Additional Information: Description of Existing Site Topography and Drainage [How is storm water runoff conveyed from the site? At a minimum, this description should answer (1) whether existing drainage conveyance is natural or urban; (2) describe existing constructed storm water conveyance systems, if applicable; and (3) is runoff from offsite conveyed through the site? if so , describe]: The existing drainage is urban. The site drains from the northwest to the southeast corner of the lot and is intercepted by an existing catch basin and a 60" RCP on Whiptail loop per drawing # 415-9. It is then directed to an existing offsite detention basin, previously designed to attenuate future development increases in flow rate. The Basin is located west of the project site near the intersection on Faraday Avenue and El Fuerte Street. (Refer to "Hydrology Study for Carlsbad Oaks North Phase 2, CT 97-13-02" prepared by O'Day Consultants Inc. Dated 11/1/2005 and Revised 7/31/2006).The drainage then continues approximately 0.43 miles north to Agua Hedionda Creek, then 5.2 miles west to the Pacific Ocean. conveyed trough the site No offsite runoff Description of Proposed Site Development and Drainage Patterns Project Description / Proposed Land Use and/or Activities: Proposed land use is for a commercial development with 3 buildings, a parking lot, underground utilities, covered trash enclosures, landscaping, and biofiltration for stormwater treatment. LisUdescribe proposed impervious features of the project (e.g ., buildings, roadways, parking lots, courtyards, athletic courts, other impervious features): Building rooftops, driveways and hardscape. LisUdescribe proposed pervious features of the project (e.g., landscape areas): Landscaping and biofiltration. Does the project include grading and changes to site topography? XYes D No Description/ Additional Information: The development will require minor grading onsite; however, slope patterns will be significantly maintained as in pre-development. Does the project include changes to site drainage (e.g ., installation of new storm water conveyance systems)? XYes No Description/ Additional Information: Proposed drainage will maintain existing site characteristics and will include biofiltration for stormwater treatment. The stormwater will be directed to biofiltration basins fitted with overflow risers. Their flow will be directed to new stromdrains onsite draining into a 60" RCP on Whiptail Loop per drawing 415-9. Peak flows will be attenuated to pre-development rates by an existing offsite detention basin located west of the project site near the intersection on Faraday Avenue and El Fuerte Street. (Refer to "Hydrology Study for Carlsbad Oaks North Phase 2, CT 97-13-02" prepared by O'Day Consultants Inc. Dated 11/1/2005 and Revised 7 /31 /2006).The drainage then continues to Encinitas Creek and the Pacific Ocean. Identify whether any of the following features, activities, and/or pollutant source areas will be present (select all that apply): X On-site storm drain inlets □ Interior floor drains and elevator shaft sump pumps □ Interior parking garages □ Need for future indoor & structural pest control X Landscape/Outdoor Pesticide Use □ Pools, spas, ponds, decorative fountains, and other water features □Foodservice X Refuse areas □ Industrial processes □ Outdoor storage of equipment or materials □ Vehicle and Equipment Cleaning □ Vehicle/Equipment Repair and Maintenance □ Fuel Dispensing Areas □ Loading Docks X Fire Sprinkler Test Water □ Miscellaneous Drain or Wash Water X Plazas, sidewalks, and parking lots Identification of Receiving Water Pollutants of Concern Describe path of storm water from the project site to the Pacific Ocean (or bay, lagoon, lake or reservoir, as applicable): Site runoff will be directed to a 60" RCP on Whiptail Loop per drawing 415-9. Peak flows will be attenuated to pre-development rates by an existing offsite detention basin located west of the project site near the intersection on Faraday Avenue and El Fuerte Street. (Refer to Hydrology Study for Carlsbad O aks North Phase 2, CT 97-13-02 prepared by O Day Consultants Inc. D ated 11 /1/2005 and Revised 7 /31/2006).The drainage then continues to Encinitas Creek and the Pacific Ocean. List any 303(d) impaired water bodies within the path of storm water from the project site to the Pacific Ocean (or bay, lagoon, lake or reservoir, as applicable), identify the pollutant(s)/stressor(s) causing impairment, and identify any TMDLs for the impaired water bodies: 303(d) Impaired Water Body Pollutant(s)/Stressor(s) TMDLs Agua Hedionda Creek Benthic Community effects, Bifenthrin, Chlorpyrifos, Cypermethrin, Tndicator, Bacteria, Malathion, Manganese, Nitrogen, Selenium, Total Dissolved Solids, Toxicity. Agua Hedionda Lagoon Toxicity Identification of Project Site Pollutants Identify pollutants anticipated from the project site based on all proposed use(s) of the site (see BMP Design Manual Appendix B.6): Also a Receiving Not Applicable to Anticipated from the Water Pollutant of Pollutant the Project Site Project Site Concern X Sediment X Nutrients X X Heavy Metals X Organic Compounds X Trash & Debris Oxygen Demanding X Substances X Oil & Grease X Bacteria & Viruses X Pesticides Hydromodification Management Requirements Do hydro modification management requirements apply (see Section 1.6 of the BMP Design Manual)? X Yes, hydromodification management flow control structural BMPs required. No, the project will discharge runoff directly to existing underground storm drains discharging directly to water storage reservoirs, lakes, enclosed embayments, or the Pacific Ocean. □ No, the project will discharge runoff directly to conveyance channels whose bed and bank are concrete-lined all the way from the point of discharge to water storage reservoirs, lakes, enclosed embayments, or the Pacific Ocean. □ No, the project will discharge runoff directly to an area identified as appropriate for an exemption by the WMAA for the watershed in which the project resides. Description/ Additional Information (to be provided if a 'No' answer has been selected above): Critical Coarse Sediment Yield Areas* *This Section only required if hydromodification manaaement reauirements aoolv Based on the maps provided within the WMAA, do potential critical coarse sediment yield areas exist within the project drainage boundaries? □Yes X No, No critical coarse sediment yield areas to be protected based on WMAA maps If yes, have any of the optional analyses presented in Section 6.2 of the BMP Design Manual been performed? □ 6.2.1 Verification of Geomorphic Landscape Units (GLUs) Onsite □ 6.2.2 Downstream Systems Sensitivity to Coarse Sediment □ 6.2.3 Optional Additional Analysis of Potential Critical Coarse Sediment Yield Areas Onsite □ No optional analyses performed, the project will avoid critical coarse sediment yield areas identified based on WMAA maps If optional analyses were performed, what is the final result? □ No critical coarse sediment yield areas to be protected based on verification of GLUs onsite □ Critical coarse sediment yield areas exist but additional analysis has determined that protection is not required. Documentation attached in Attachment 8 of the SWQMP. □ Critical coarse sediment yield areas exist and require protection. The project will implement management measures described in Sections 6.2.4 and 6.2.5 as applicable, and the areas are identified on the SWQMP Exhibit. Discussion/ Additional Information: Flow CCritontrol for Post-Project Runoff" *This Section only required if hydromodification management requirements aooly List and describe point(s) of compliance (POCs) for flow control for hydromodification management (see Section 6.3.1 ). For each POC, provide a POC identification name or number correlating to the project's HMP Exhibit and a receiving channel identification name or number correlating to the project's HMP Exhibit. POC 1 @ t he SE corner of the site. Has a geomorphic assessment been performed for the receiving channel(s)? X No, the low flow threshold is 0.1 Q2 ( default low flow threshold) □ Yes, the result is the low flow threshold is 0.1 Q2 □ Yes, the result is the low flow threshold is 0.3Q2 □ Yes, the result is the low flow threshold is 0.5Q2 If a geomorphic assessment has been performed, provide title, date, and preparer: Discussion/ Additional Information: (optional) Other Site Requirements and Constraints When applicable, list other site requirements or constraints that will influence storm water management design, such as zoning requirements including setbacks and open space, or City codes governing minimum street width, sidewalk construction, allowable pavement types, and drainage requirements. Infiltration based treatment BMPs are not feasible, according to Worksheet C.4-1 "Categorization of Infiltration Condition" prepared by the geotechnical consultant. Optional Additional Information or Continuation of Previous Sections As Needed This space provided for additional information or continuation of information from previous sections as needed. [Insert City's Standard Project Requirement Checklist Form E-36 (here)] C cityof Carlsbad Project Name: Lot 3, Whiptail Loop Project ID: DWG No. or Building Permit No.: ST AND ARD PROJECT REQUIREMENT CHECKLIST E-36 Project Information Source Control BMPs Development Services Land Development Engineering 1635 Faraday Avenue (760) 602-2750 www.carlsbadca.gov All development projects must implement source control BMPs SC-1 through SC-6 where applicable and feasible. See Chapter 4 and Appendix E.1 of the BMP Design Manual (Volume 5 of City Engineering Standards) for information to implement source control BMPs shown in this checklist. Answer each category below pursuant to the following. • "Yes" means the project will implement the source control BMP as described in Chapter 4 and/or Appendix E.1 of the Model BMP Design Manual. Discussion/justification is not required. • "No" means the BMP is applicable to the project but it is not feasible to implement. Discussion/justification must be provided. Please add attachments if more space is needed. • "N/A" means the BMP is not applicable at the project site because the project does not include the feature that is addressed by the BMP (e.g., the project has no outdoor materials storage areas). Discussion/justification may be provided. Source Control Requirement Applied? SC-1 Prevention of Illicit Discharges into the MS4 Iii Yes □ No □ N/A Discussion/justification if SC-1 not implemented: SC-2 Storm Drain Stenciling or Signage Iii Yes □ No □ N/A Discussion/justification if SC-2 not implemented: SC-3 Protect Outdoor Materials Storage Areas from Rainfall, Run-On, Runoff, and Wind □ Yes D No Iii N/A Dispersal Discussion/justification if SC-3 not implemented : none proposed E-36 Page 1 of 4 Revised 09/16 Source Control Requirement (continued) Aoolied? SC-4 Protect Materials Stored in Outdoor Work Areas from Rainfall, Run-On, Runoff, and □ Yes □ No Iii N/A Wind Dispersal Discussion/justification if SC-4 not implemented: none proposed SC-5 Protect Trash Storage Areas from Rainfall, Run-On , Runoff, and Wind Dispersal Iii Yes □ No □ N/A Discussion/justification if SC-5 not implemented: SC-6 Additional BMPs based on Potential Sources of Runoff Pollutants must answer for each source listed below and identify additional BMPs. (See Table in Aooendix E.1 of BMP Manual for Quidance). □ On-site storm drain inlets Iii Yes □ No □ N/A □ Interior floor drains and elevator shaft sump pumps □ Yes □ No Iii N/A □ Interior parking garages □ Yes □ No Iii N/A □ Need for future indoor & structural pest control □ Yes □ No Iii N/A □ Landscape/Outdoor Pesticide Use Iii Yes □ No □ N/A □ Pools, spas, ponds, decorative fountains, and other water features □ Yes □ No Iii N/A □ Food service □ Yes □ No Iii N/A □ Refuse areas Iii Yes □ No □ N/A □ Industrial processes □ Yes □ No Iii N/A □ Outdoor storage of equipment or materials □ Yes □ No Iii N/A □ Vehicle and Equipment Cleaning □ Yes □ No Iii N/A □ Vehicle/Equipment Repair and Maintenance □ Yes □ No Iii N/A □ Fuel Dispensing Areas □ Yes □ No Iii N/A □ Loading Docks □ Yes □ No Iii N/A □ Fire Sprinkler Test Water Iii Yes □ No □ N/A □ Miscellaneous Drain or Wash Water □ Yes □ No Iii N/A □ Plazas, sidewalks, and parking lots Iii Yes □ No □ N/A For "Yes" answers, identify the additional BMP per Appendix E.1. Provide justification for "No" answers. (SEE E-1 SOURCE CONTROL BMP REQUIREMENTS AT THE END OF CHECKLIST E-36) E-36 Page 2 of 4 Revised 09/16 Site Design BMPs All development projects must implement site design BMPs SD-1 through SD-8 where applicable and feasible. See Chapter 4 and Appendix E.2 thru E.6 of the BMP Design Manual (Volume 5 of City Engineering Standards) for information to implement site design BMPs shown in this checklist. Answer each category below pursuant to the following. • "Yes" means the project will implement the site design BMPs as described in Chapter 4 and/or Appendix E.2 thru E.6 of the Model BMP Design Manual. Discussion / justification is not required. • "No" means the BMPs is applicable to the project but it is not feasible to implement. Discussion/justification must be provided. Please add attachments if more space is needed. • "N/A" means the BMPs is not applicable at the project site because the project does not include the feature that is addressed by the BMPs (e.g., the project site has no existing natural areas to conserve). Discussion/justification may be provided. Site Design Requirement I Applied? SD-1 Maintain Natural Drainage Pathways and Hydrologic Features I [i] Yes I □ No I □ N/A Discussion/justification if SD-1 not implemented: SD-2 Conserve Natural Areas, Soils, and Vegetation I □ Yes I □ No I [i] N/A Discussion/justification if SD-2 not implemented: none existing SD-3 Minimize Impervious Area I [i] Yes I □ No I □ N/A Discussion/justification if SD-3 not implemented: SD-4 Minimize Soil Compaction I [i] Yes I □ No I □ N/A Discussion/justification if SD-4 not implemented: SD-5 Impervious Area Dispersion I [i] Yes I □ No I □ N/A Discussion/justification if SD-5 not implemented: E-36 Page 3 of 4 Revised 09/16 Site Design Requirement (continued) I Aoolied? SD-6 Runoff Collection I Iii Yes I □ No I □ N/A Discussion/justification if SD-6 not implemented: SD-7 Landscaping with Native or Drought Tolerant Species I Iii Yes I □ No I □ N/A Discussion/justification if SD-7 not implemented: SD-8 Harvestinq and Usinq Precipitation I □ Yes I Iii No I □ NIA Discussion/justification if SD-8 not implemented: not feasible. Refer to Form 1-7 E-36 Page 4 of 4 Revised 09/16 Structural BMP Summary Information [Copy this page as needed to provide information for each individual proposed structural BMP] Structural BMP ID No. Biofiltration Basin A Drainage Area Map Sheet No. 1 Type of structural BMP: □ Retention by harvest and use (HU-1) □ Retention by infiltration basin (INF-1) □ Retention by bioretention (INF-2) □ Retention by permeable pavement (INF-3) □ Partial retention by biofiltration with partial retention (PR-1) X Biofiltration (BF-1) □ Flow-thru treatment control included as pre-treatment/forebay for an onsite retention or biofiltration BMP (provide BMP type/description and indicate which onsite retention or biofiltration BMP it serves in discussion section below) □ Detention pond or vault for hydromodification management □ Other (describe in discussion section below) Purpose: Pollutant control only □ Hydromodification control only X Combined pollutant control and hydromodification control □ Pre-treatment/forebay for another structural BMP □ Other (describe in discussion section below) Discussion (as needed): Structural BMP Summary Information [Copy this page as needed to provide information for each individual proposed structural BMP] Structural BMP ID No. Biofiltration Basin B Drainage Area Map Sheet No. 1 Type of structural BMP: □ Retention by harvest and use (HU-1) □ Retention by infiltration basin (I NF-1) □ Retention by bioretention (INF-2) □ Retention by permeable pavement (INF-3) □ Partial retention by biofiltration with partial retention (PR-1) X Biofiltration (BF-1) □ Flow-thru treatment control included as pre-treatment/forebay for an onsite retention or biofiltration BMP (provide BMP type/description and indicate which onsite retention or biofiltration BMP it serves in discussion section below) □ Detention pond or vault for hydromodification management □ Other (describe in discussion section below) Purpose: Pollutant control only □ Hydromodification control only X Combined pollutant control and hydromodification control □ Pre-treatment/forebay for another structural BMP □ Other (describe in discussion section below) Discussion (as needed): Appendix E: BMP Design Fact Sheets E.1 Source Control BMP Requirements Worksheet E.1-1: Source Control BMP Requirements How to comply: Projects must comply with this requirement by implementing all source control BMPs listed in this section that are applicable and feasible for their project. Applicability must be determined through consideration of the development project's features and anticipated pollutant sources. Appendix E.1 provides guidance for identifying source control BMPs applicable to a project. The Standard and PDP SWQMP templates include sections that must be used to document compliance with source control BMP requirements. How to use this worksheet: 1. Review Column 1 and identify which of these potential sources of storm water pollutants apply to your site. Check each box that applies . 2. Review Column 2 and incorporate all of the corresponding applicable BMPs in your project site plan. 3. Review Columns 3 and 4 and incorporate all of the corresponding applicable permanent controls and operational BMPs in a table in your project- specific storm water management report. Describe your specific BMPs in an accompanying narrative, and explain any special conditions or situations that required omitting BMPs or substituting alternatives. E-3 February 26, 2016 1 Potential Sources of Runoff Pollutants ~ A. Onsite storm drain inlets D Not Applicable fil 2 Permanent Controls-Show on Drawings Locations of inlets. 3 Permanent Controls-List in Table and Narrative ~ Mark all inlets with the words "No Dumping! Flows to Bay" or similar. See stencil template provided in Appendix I-4 E-4 Appendix E: BMP Design Fact Sheets 4 Operational BMPs-Include in Table and Narrative Kl Maintain and periodically repaint or replace inlet markings. E3 Provide storm water pollution prevention information to new site owners, lessees, or operators. :CJ See applicable operational BMPs in Fact Sheet SC-44, "Drainage System Maintenance," in the CASQA Storm Water Quality Handbooks at www .casqa.org/resources /bmp- handbooks /municipal-bmp- handbook. ~ Include the following in lease agreements: "Tenant shall not allow anyone to discharge anything to storm drains or to store or deposit materials so as to create a potential discharge to storm drains." February 26, 2016 If These Sources Will Be on the Project Site ... □ fi:l □ Clil 1 Potential Sources of Runoff Pollutants B. Interior floor drains and elevator shaft sump pumps Not Aeelicable C. Interior parking garages Not Applicable □ Dl. Need for future indoor & structural pest control l:i:I Not Applicable Appendix E: BMP Design Fact Sheets . .. Then Your SWQMP must consider These Source Control BMPs 2 Permanent Controls-Show on Drawings 3 Permanent Controls-List in Table and Narrative □ State that interior floor drains and elevator shaft sump pumps will be plumbed to sanitary sewer. □ State that parking garage floor drains will be plumbed to the sanitary sewer. □ Note building design features that discourage entry of pests. E-5 4 Operational BMPs-Include in Table and Narrative □ Inspect and maintain drains to prevent blockages and overflow. □ Inspect and maintain drains to prevent blockages and overflow. □ Provide Integrated Pest Management information to owners, lessees, and operators. February 26, 2016 1 Potential Sources of Runoff Pollutants IXI D2. Landscape/ Outdoor Pesticide Use □ Not Applicable 2 Permanent Controls-Show on Drawings (Z1 0 Ill Show locations of existing trees or areas of shrubs and ground cover to be undisturbed and retained. Show self-retaining landscape areas, if any. Show storm water treatment facilities. 3 Permanent Controls-List in Table and Narrative State that final landscape plans will accomplish all of the fo llowing. lJ Preserve existrng drought tolerant trees, shrubs, and ground cover to the maximum extent possible. ~ Design landscaping to rrururruze irrigation and runoff, to promote surface infiltration where appropriate, and to minimize the use of fertilizers and pesticides that can contribute to storm water pollution. Cll Where landscaped areas are used to retain or detain storm water, specify plants that are tolerant of periodic saturated soil conditions. ~ Consider using pest-resistant plants, especially adjacent to hardscape. ij To ensure successful establishment, select plants appropriate to site soils, slopes, climate, sun, wind, rain, land use, air movement, ecological consistency, and plant interactions. E-6 Appendix E: BMP Design Fact Sheets 4 Operational BMPs-lnclude in Table and Narrative Cli1 Maintain landscaping using minimum or no pesticides. q See applicable operational BMPs in Fact Sheet SC-41, "Building and Grounds Maintenance," in the CASQA Storm Water Quality Handbooks at www .casqa.org/resources /bmp -handbooks/municipal-bmp- handbook. 1,.1 Provide IPM information to new owners, lessees and operators. February 26, 2016 If These Sources Will Be on the Project Site ... 1 Potential Sources of Runoff Pollutants □ E. Pools, spas, ponds, decorative fountains, and other water features. Iii Not Applicable □ F. Food service ~ Not Applicable Appendix E: BMP Design Fact Sheets . .. Then Your SWQMP must consider These Source Control BMPs 2 Permanent Controls-Show on Drawings □ Show location of water feature and a sanitary sewer cleanout in an accessible area within 10 feet. □ For restaurants, grocery stores, and other food service operations, show location (indoors or in a covered area outdoors) of a floor sink or other area for cleaning floor mats, containers, and equipment. □ On the drawing, show a note that this drain will be connected to a grease interceptor before discharging to the sanitary sewer. 3 Permanent Controls-List in Table and Narrative □ If the local municipality requires pools to be plumbed to the sanitary sewer, place a note on the plans and state in the narrative that this connection will be made according to local requirements. □ Describe the location and features of the designated cleaning area. □ Describe the items to be cleaned in this facility and how it has been sized to ensure that the largest items can be accommodated. E-7 4 Operational BMPs-lnclude in Table and Narrative □ See applicable operational BMPs in Fact Sheet SC-72, "Fountain and Pool Maintenance," in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources /bm p-handbooks/municipal- bmp-handbook. February 26, 2016 If These Sources Will Be on the Project Site 1 Potential Sources of rn G. Refuse areas D Not Applicable Appendix E: BMP Design Fact Sheets ... Then Your SWQMP must consider These Source Control BMPs 2 Permanent Controls-Show on Drawings IX! Show where site refuse and recycled materials will be handled and stored for pickup. See local municipal requirements for sizes and other details of refuse areas. l]I If dumpsters or other receptacles are outdoors, show how the designated area will be covered, graded, and paved to prevent run- on and show locations of berms to prevent runoff from the area. Also show how the designated area will be protected from wind dispersal. Gl Any drains from dumpsters, compactors, and tallow bin areas must be connected to a grease removal device before discharge to sanitary sewer. 3 Permanent Controls-List in Table and Narrative ~ State how site refuse will be handled and provide supporting detail to what is shown on plans. ~ State that signs will be posted on or near dumpsters with the words "Do not dump hazardous materials here" or sim.ilar. E-8 4 Operational BMPs-lnclude in Table and Narrative 6'I State how the following will be implemented: Provide adequate number of receptacles. Inspect receptacles regularly; repair or replace leaky receptacles. Keep receptacles covered. Prohibit/ prevent dumping of liquid or hazardous wastes. Post "no hazardous materials" signs. Inspect and pick up litter daily and clean up spills immediately. Keep spill control materials available on-site. See Fact Sheet SC-34, "Waste Handling and Disposal" in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources/bmp- handbooks /municipal-bmp-handbook. February 26, 2016 1 Potential Sources of Runoff Pollutants □ H. Industrial processes. :0 Not Applicable □ I. Outdoor storage of equipment or materials. (Sec rows J and K for source control measures for vehicle cleaning, repair, and maintenance.) 6'l Not Applicable 2 Permanent Controls-Show on Drawings □ □ □ Show process area. Show any outdoor storage areas, including how materials will be covered. Show how areas will be graded and bermed to prevent run-on or runoff from area and protected from wind dispersal. Storage of non-hazardous liquids must be covered by a roof and/ or drain to the sanitary sewer system, and be contained by berms, dikes, liners, or vaults. □ Storage of hazardous materials and wastes must be in compliance with the local hazardous materials ordinance and a Hazardous Materials Management Plan for the site. Appendix E: BMP Design Fact Sheets 3 Permanent Controls-Listin Table and Narrative □ If industrial processes are to be located onsite, state: "All process activities to be performed indoors. No processes to drain to exterior or to storm drain system." □ Include a detailed description of materials to be stored, storage areas, and structural features to prevent pollutants from entering storm drains. Where appropriate, reference documentation of compliance with the requirements of local Hazardous Materials Programs for: • Hazardous Waste Generation • Hazardous Materials Release Response and Inventory • California Accidental Release Prevention Program • Aboveground Storage Tank • Uniform Fire Code Article 80 Section 103(6) & (c) 1991 • Underground Storage Tank E-9 4 Operational BMPs-Include in Table and Narrative Table and Narrative □ See Fact Sheet SC-10, "Non- Storm Water Discharges" in the CASQA Storm Water Quality Handbooks at https: // www.casqa.org/resou rces/bmo-handbooks. □ See the Fact Sheets SC-31, "Outdoor Liquid Container Storage" and SC-33, "Outdoor Storage of Raw Materials" in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources /bm p-handbooks/municipal-bmp- handbook. February 26, 2016 1 Potential Sources of Runoff Pollutants □ J. Vehicle and Equipment Cleaning ~ Not Applicable 2 Permanent Controls-Show on Drawings □ Show on drawings as appropriate: (1) Commercial/industrial facilities having vehicle / equipment cleaning needs must either provide a covered, bermed area for washing actl.Vltles or discourage vehicle/ equipment washing by removing hose bibs and installing signs prohibiting such uses. (2) Multi-dwelling complexes must have a paved, bermed, and covered car wash area (unless car washing is prohibited onsite and hoses are provided with an automatic shut- off to discourage such use). (3) Washing areas for cars, vehicles, and equipment must be paved, designed to prevent run-on to or runoff from the area, and plumbed to drain to the sanitary sewer. (4) Commercial car wash facilities must be designed such that no runoff from the facility is discharged to the storm drain system. Wastewater from the facility must discharge to the sanitary sewer, or a wastewater reclamation system must be installed. E-10 3 Permanent Controls-List in Table and Narrative □ If a car wash area is not provided, describe measures taken to discourage onsite car washing and explain how these will be enforced. Appendix E: BMP Design Fact Sheets 4 Operational BMPs-lnclude in Table and Narrative Describe operational measures to implement the following (if applicable): □ Washwater from vehicle and equipment washing operations must not be discharged to the storm drain system. □ Car dealerships and similar may rinse cars with water only. □ See Fact Sheet SC-21, "Vehicle and E quipment Cleaning," in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources/bm p-handbooks /municipal-bmp- handbook. February 26, 2016 1 Potential Sources of Runoff Pollutants □ K. Vehicle/Equipment Repair and Maintenance E:I Not Applicable □ □ □ 2 Permanent Controls-Show on Drawings Accommodate all vehicle equipment repair and maintenance indoors. Or designate an outdoor work area and design the area to protect from rainfall, run-on runoff, and wind dispersal. Show secondary containment for exterior work areas where motor oil, brake fluid, gasoline, diesel fuel, radiator fluid, acid- containing batteries or other hazardous materials or hazardous wastes are used or stored. Drains must not be installed within the secondary containment areas. Add a note on the plans that states either (1) there are no floor drains, or (2) floor drains are connected to wastewater pretreatment systems prior to discharge to the sanitary sewer and an industrial waste discharge permit will be obtained. 3 Permanent Controls-List in Table and Narrative □ □ □ State that no vehicle repair or maintenance will be done outdoors, or else describe the required features of the outdoor work area. State that there are no floor drains or if there are floor drains, note the agency from which an industrial waste discharge permit will be obtained and that the design meets that agency's requirements. State that there are no tanks, containers or sinks to be used for parts cleaning or rinsing or, if there are, note the agency from which an industrial waste discharge permit will be obtained and that the design meets that agency's requirements. E-11 Appendix E: BMP Design Fact Sheets 4 Operational BMPs-Include in Table and Narrative In the report, note that all of the following restrictions apply to use the site: □ No person must dispose of, nor permit the disposal, directly or indirectly of vehicle fluids, hazardous materials, or rinsewater from parts cleaning into storm drains. □ No vehicle fluid removal must be performed outside a building, nor on asphalt or ground surfaces, whether inside or outside a building, except in such a manner as to ensure that any spilled fluid will be in an area of secondary containment. Leaking vehicle fluids must be contained or drained from the vehicle immediately. □ No person must leave unattended drip parts or other open containers containing vehicle fluid, unless such containers are in use or in an area of secondary containment. February 26, 2016 □ Kl 1 Potential Sources of Runoff Pollutants 2 Permanent Controls-Show on Drawings L. Fuel Dispensing I □ Fueling areas 16 must have impermeable floors (i.e., portland cement concrete or equivalent smooth impervious surface) that are (1) graded Areas Not Applicable at the minimum slope necessary to prevent ponding; and (2) separated from the rest of the site by a grade break that prevents run-on of storm water to the MEP. D Fueling areas must be covered by a canopy that extends a minimum of ten feet in each direction from each pump. [Alternative: The fueling area must be covered and the cover's minimum dimensions must be equal to or greater than the area within the grade break or fuel dispensing areal.] The canopy [or cover] must not drain onto the fueling area. 3 Permanent Controls-List in Table and Narrative Appendix E: BMP Design Fact Sheets 4 Operational BMPs-Include in Table and Narrative □ The property owner must dry sweep the fueling area routinely. D See the Business Guide Sheet, "Automotive Service-Service Stations" in the CASQA Storm Water Quality Handbooks at https://www.casqa.org/resources/b mp-handbooks. 16 The fueling area must be defined as the area extending a minimum of 6.5 feet from the comer of each fuel dispenser or the length at which the hose and nozzle assembly may be operated plus a minimum of one foot, whichever is greater. E-12 February 26, 2016 1 Potential Sources of Runoff Pollutants M. Loading Docks Kl Not Applicable 2 Permanent Controls-Show on Drawings □ Show a preliminary design for the loading dock area, including roofing and drainage. Loading docks must be covered and/ or graded to minimize run-on to and runoff from the loading area. Roof downspouts must be positioned to direct storm water away from the loading area. Water from loading dock areas should be drained to the sanitary sewer where feasible. Direct connections to storm drains from depressed loading docks are prohibited. □ Loading dock areas draining directly to the sanitary sewer must be equipped with a spill control valve or equivalent device, which must be kept closed during periods of operation. □ Provide a roof overhang over the loading area or install door skirts (cowling) at each bay that enclose the end of the trailer. 3 Permanent Controls-List in E-13 Appendix E: BMP Design Fact Sheets 4 Operational BMPs-Include in Table and Narrative D Move loaded and unloaded items indoors as soon as possible. □ See Fact Sheet SC-30, "Outdoor Loading and Unloading," in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources /bmp- handbooks /municipal-bmp-handbook. February 26, 2016 1 Potential Sources of Runoff Pollutants ~ N. Fire Sprinkler Test Water D Not Applicable 0. Miscellaneous Drain or Wash Water □ Boiler drain lines □ Condensate drain lines □ Rooftop equipment □ Drainage sumps □ Roofing, gutters, and trim Ciit Not Applicable 2 Permanent Controls- Show on Drawings Appendix E: BMP Design Fact Sheets ~ 3 Permanent Controls-List in Table and Narrative Provide a means to drain fire sprinkler test water to the sanitary sewer. □ Boiler drain lines must be directly or indirectly connected to the sanitary sewer system and may not discharge to the storm drain system. □ Condensate drain lines may discharge to landscaped areas if the flow is small enough that runoff will not occur. Condensate drain lines may not discharge to the storm drain sys tem. □ Rooftop mounted equipment with potential to produce pollutants must be roofed and/ or have secondary containment. □ Any drainage sumps onsite must feature a sediment sump to reduce the quantity of sediment in pumped water. □ Avoid roofing, gutters, and trim made of copper or other unprotected metals that may leach into runoff. E-14 4 Operational BMPs-Include in Table and Narrative q See the note in Fact Sheet SC- 41, "Building and Grounds Maintenance," in the CASQA Storm Water Quality Handbooks at www.casqa.org/resources /bm p-handbooks/municipal-bmp- handbook February 26, 2016 1 Potential Sources of Runoff Pollutants Kl P. sidewalks, parking lots. D Not Applicable Plazas, and 2 Permanent Controls-Show on Drawings 3 Permanent Controls-List in Table and Narrative E-15 Appendix E: BMP Design Fact Sheets 4 Operational BMPs-Include in Table and Narrative lia Plazas, sidewalks, and parking lots must be swept regularly to prevent the accumulation of litter and debris. Debris from pressure washing must be collected to prevent entry into the storm drain system. Washwater containing any cleaning agent or degreaser must be collected and discharged to the sanitary sewer and not discharged to a storm drain. February 26, 2016 ATTACHMENT 1 BACKUP FOR PDP POLLUTANT CONTROL BMPS This is the cover sheet for Attachment 1 . Check which Items are Included behind this cover sheet: Attachment Contents Checklist Sequence Attachment 1 a OMA Exhibit (Required) Attachment 1 b Attachment 1 c Attachment 1 d See OMA Exhibit Checklist on the back of this Attachment cover sheet. (24"x36" Exhibit typically required) Tabular Summary of DMAs Showing OMA ID matching OMA Exhibit, OMA Area, and OMA Type (Required)* *Provide table in this Attachment OR on OMA Exhibit in Attachment 1 a Form 1-7, Harvest and Use Feasibility Screening Checklist (Required unless the entire project will use infiltration BMPs) Refer to Appendix B.3-1 of the BMP Design Manual to complete Form 1-7. Form 1-8, Categorization of Infiltration Feasibility Condition (Required unless the project will use harvest and use BMPs) Refer to Appendices C and D of the BMP Design Manual to complete Form 1-8. X Included X Included on OMA Exhibit in Attachment 1 a □ Included as Attachment 1 b, separate from OMA Exhibit X Included □ Not included because the entire project will use infiltration BMPs X Included □ Not included because the entire project will use harvest and use BMPs Attachment 1e Pollutant Control BMP Design X Included Worksheets / Calculations (Required) Refer to Appendices B and E of the BMP Design Manual for structural pollutant control BMP design guidelines ATTACHMENT 1 Use this checklist to ensure the required information has been included on the OMA Exhibit: The OMA Exhibit must identify: □ Underlying hydrologic soil group □ Approximate depth to groundwater □ Existing natural hydrologic features (watercourses, seeps, springs, wetlands) □ Critical coarse sediment yield areas to be protected (if present) □ Existing topography and impervious areas □ Existing and proposed site drainage network and connections to drainage offsite □ Proposed grading □ Proposed impervious features □ Proposed design features and surface treatments used to minimize imperviousness □ Drainage management area (OMA) boundaries, OMA ID numbers, and OMA areas (square footage or acreage), and OMA type (i.e., drains to BMP, self-retaining, or self-mitigating) □ Structural BMPs (identify location and type of BMP) --------------------------____L__ -------------------------. --____.,/~· ! "'f' CT.. •,, '------------- ------2:---- -----• • I ' ;·:t:.-::.. -!'~~-:; ' :. .,. ' I-,-~-~ . • wttPTALLOOP ~ WMIPTAI.LOOP l,1 t~ C l-l...kl :JI ----7 .. .J:..•-~-____::.::::-~----4---___,!_t~-------!-~---:.----F,-~~:---r--pfk{~oif·!:.$_~------- ----,,_ ... _..,. ___ ..,_h -N. .._ ·-~::T'~-·--------~_,;·~~~-1 \,-,.,c..,.._ ---1 {1&111,f /t~E__:-?""51)11.,1JJ.r )tt, 1), J)jf),_ /)))}),1.))...1-7)//,.,,,..//~ •/J/1.✓)j/ )/tt;)J-,, ': I \ (~;~.ICl U•,>f ;•·1 ,t-:{,¢ ~ J/' ··./' t '/ , . I .1. ' h I // --, -t •/• ./,! ~~~ JO ,s O JO 60 i-L-=:J L== SCALE: 1• -JO' PLANS PREP,o,REO BY: SP EAR & ASSOCIATES, INC. CIVIL. EN0 1NEERtN0 & L.AND SURVe.VINO '475 PROOUCnON STREET, SAN MARCOS, CA 92078 Pl-lONE (760) 736-2040 FAX (760) 736-•866 ~~--~~~--- TC FLOW_PA1H L•560' LF-- ~ T T • bl-It> !'' 1 'CJ • > /1.: J:·. ~n ACRES f 8UILOINO•c• ,,.., J.OO'f!!!:!1 "'<NN!XTT0 ~ 1 /·/IO?fUSllff"· J"•~S..01'ASnl .'IO,JJ)-o,,aJ·a-aoa.t;Sfr»tl (ASrllMl/l)WrR•al'OR051TT "\\,.,.-. ~ Kl6Wl" ('U 51XS --~-::Sl~N'°i~ "°' '/l;/1 :;Jr.~~ !i£.M6D.~1 Oltl<l's,'S1IM :::: 1 [£ OO'rHf'OtS(»S ""'"' (SC£"1J1'£1£/i£0N} . .J:..":a""'~t"" to.so· t~ Gl.l'ffl.tllP I!! .:i_,..,. i ASTIIM'.l. 51STCM: IA'9i' '""""""" ,·t11o1.P£1ifOO.rrDA(;!JlaR«I.NN (.J' (Tf'SC1 IN Olltflct PU.TC} nPICAL DOM. ~ O(lnIT C&INCCTION IIOT-10-SCN.£ T 1uuii..o-1• :-.::::-- T raJ!ifDIIJ!..J a'ltQC T'IPf OPCWII; F(:,/IJMlfOWIC(f'v.T[~ I JlfTIOJflOIM\&IHCBafS I o/ At~;;;~ai~0 •·'11i12"P1AlC 0• ¾"MO<CM.-i!.D IIIJlifOWIC£JltAf[ !POYfstolllOCA!CH tMSWIIT[f(J(lll"AL! '"tM..PCliFaiA!CD &_C-BJ~ ~INTENANCE PLATE OETAIL Al1JDI ID INTCRIORINlIT 11\U or J6'1JiS·etfCH~ -~':.J.;.Ck.~·;v-: ?J t ---·--- ,t~; 't I. IULOtNQ"A" ::~-: ,.I ,·, / / :.-/,, ,. ORAINAGE MANAGEMENT AREA BREAKDOWN ~ Nl£A SiRF,11:C I me:l .. ,,,.. ~~ A'I~'!)~ ll'I SEIF~~!MZ -..-RUY>P J5.151SQFT I 2tt_,J«1son ~AISI.£ •1,tJ5gSQn 41,4!1$SOn oson ~ om son 1,165sor1 osor, LN/IJ5l:,APN; Jl,MSOFT J:S,"'°SOFT 1,5/0SOFT 114JC5son 1 ,01ason I 1,5,oson ,OlJtS//fNE,A.· 215.l~SOFT LEGEND OF SYMBOLS SfPCctCCNTUlt./JC cx1srw;ca,iraRS DlllfCf/CMrTDIMINAIZ /Mf4/Nll(L '-KA @ ~ D/iAJIW,Cl>IANAGDCNf -"KA lESIGMI"-"' L!KLST nuv PAIH l'IKX'OS£.D SJIJ/lf D/WN ,CAICHWIN<PVI> PROJECT ADORESS: LOT .I, llf-FTA.I. LOOP CAlit5BNJ,CA91008 PROPER'TY OWNER CARI.S8AD (WIS NOR TH \£N Tl.IRES LP. ADORCSS:J51$K(N'l'OfJS11l(Cr.Sl.ftr200 SAN DICOO, CA 91110 CON/ACT: DENI SlillTH •TECH CCNIRACTORS PH&IC NO: ('19) 11J-l66J fsirul CITY OF' CARLSBAD fsi'CNl L...l...J CNCilMC(li!l"-G DCPMHMCMl LJ_j l'OST Dg'r'tlDPWENT DWA PUM FOR: LOT 3, WHIPTAIL LOOP CARLS8AO, CA 92008 Appendix B: Storm Water Pollutant Control Hydrologic Calculations and Sizing Methods Wkh B31H d U F "b"li S . Harvest and Use Feasibility Screening Form 1-7 1. Is there a demand for harvested water (check all that apply) at the project site that is reliably present during the wet season? IXI Toilet and urinal flushing IXI Landscape irrigation D Other: _____ _ 2. If there is a demand; estimate the anticipated average wet season demand over a period of 36 hours. Guidance for planning level demand calculations for toilet/urinal flushing and landscape irrigation is provided in Section B.3.2. Toilet & Urinal Flushing: 20 employees (36 hour total) = 44.1 c.f. Landscape Irrigation: Total Planted Area 74,715 s.f., w/drought tolerant low water use (36 hour total) = 60 c.f. Anticipated Total Use Over 36 hours = 104 c.f. 3. Calculate the DCV using worksheet B-2.1. 7,662 c.f. 0.25 DCV = 1,916 c.f. 3a. Is the 36-hour demand greater than or equal to the DCV? Yes /X No ~ JJ Harvest and use appears to be feasible. Conduct more detailed evaluation and sizing calculations to confirm that DCV can be used at an adequate rate to meet drawdown criteria. 36. Is the 36-hour demand greater than 0.25DCV but less than the full DCV? Yes /X No ~ Harvest and use may be feasible. Conduct more detailed evaluation and sizing calculations to determine feasibility. Harvest and use may only be able to be used for a portion of the site, or (optionally) the storage may need to be upsized to meet long term capture targets while draining in longer than 36 hours. 3c. Is the 36-hour demand less than 0.25DCV? XYes Harvest and use is considered to be infeasible. X Appendix I: Forms and Checklists '"~ c~~~:gorizati~~ of !~filtration Feasibility Form 1-8 .. , Condition Part 1-Full Infiltration Feasibility Screening Criteria Would infiltration of the full design volume be feasible from a physical perspective without any undesirable consequences that cannot be reasonably mitigated? Criteria Screening Question Is the estimated reliable infiltration rate below proposed facility locations greater than 0.5 inches per hour? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.2 and Appendix D. Provide basis: Yes No X As discussed in Sections 4 and 8.13 of the update geotechnical report, the lot consists of dense to very stiff compacted fill overlying hard granitic rock. The bedrock is also exposed at grade. After planned grading, the compacted fill will be approximately 5 to 55 feet thick and bedrock will also be near or at grade. Previous infiltration testing performed on other lots within the Carlsbad Oaks North Business Park with similar soi l conditions (see Geocon Inc., report titled Update Geotechnical Report, Carlsbad Oaks North Business Park -Lol 17, Carlsbad, California, dated March 25, 2016 (Proeject No. 06442-32-21) indicated a factored infiltration rate between J0-4 to 10-1 iph (after applying a feasibility factor of safety of2). 2 Can infiltration greater than 0.5 inches per hour be allowed without increasing risk of geotechnical hazards ( slope stability, groundwater mounding, utilities, or other factors) that cannot be mitigated to an acceptable level? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.2. Provide basis: X rrhe site is underlain by dense to very stiff compacted fill overlying hard granitic rock. After planned grading, the compacted fill will be approximately 5 to 50 feet thick and bedrock will also be near or at grade. Based on existing and ultimate geologic conditions, infiltration could not be incorporated without increasing the risk of geotechnical hazards including uncontrolled water lateral migration, shrinking and swelling, induced hydro-compression of the fill and water mi gration within pipe zone of underground utilities. 1-3 February 2016 Appendix I: Forms and Checklists Criteria 3 Form I-8 Page 2 of 4 Screening Question Can infiltration greater than 0.5 inches per hour be allowed without increasing risk of groundwater contamination ( shallow water table, storm water pollutants or other factors) that cannot be mitigated to an acceptable level? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.3. Provide basis: Yes No X Groundwater is not located within 10 feet of proposed BMP basins. The risk of storm water infiltration adversely impacting groundwater is considered negligible. 4 Can infiltration greater than 0.5 inches per hour be allowed without causing potential water balance issues such as change of seasonality of ephemeral streams or increased discharge of contaminated groundwater to surface waters? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.3. Provide basis: Researching downstream water rights and evaluating water balance issues to stream flows is beyond the scope of the geotechnical engineer. Part 1 Result * If all answers to rows 1 -4 are "Yes" a full infiltration design is potentially feasible. The feasibility screening category is Full Infiltration If any answer from row 1-4 is "No", infiltration may be possible to some extent but would not generally be feasible or desirable to achieve a "full infiltration" design. Proceed to Part 2 NO *To be completed using gathered site information and best professional judgment considering the definition ofMEP in the MS4 Permit. Additional tes ting and/ or studies may be required by the City to substantiate findings. 1-4 February 2016 Appendix I: Forms and Checklists Part 2 -Partial Infiltration vs. No Infiltration Feasibility ScreeningCriteria Would infiltration of water in any appreciable amount be physically feasible without any negative consequences that cannot be reasonably mitigated? Criteria 5 Screening Question Do soil and geologic conditions allow for infiltration in any appreciable rate or volume? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.2 and AppendixD. Provide basis: Yes No X The site is underlain by dense to very stiff compacted fill overlying hard granitic rock. After planned grading, the compacted fill will be approximately 5 to 50 feet thick. The bedrock is also exposed at grade. Previous infiltration testing performed on other lots within the Carlsbad Oaks North Business Park with similar soi l conditions (see Geocon Inc., report titled Update Geotechnical Report, Carlsbad Oaks North Business Park -Loi 17, Carlsbad, California, dated March 25, 2016 (Proeject No. 06442-32-21) indicated a factored infiltration rate between 10-4 to 10-1 iph (after applying a feasibility factor of safety of 2). Summarize findings of studies; provide reference to studies, calculations, maps, data sources, etc. Provide narrative discussion of study/ data source applicability and why it was not feasible to mitigate low infiltration rates. 6 Can Infiltration in any appreciable quantity be allowed without increasing risk of geotechnical hazards (slope stability, groundwater mounding, utilities, or other factors) that cannot be mitigated to an acceptable level? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.2. Provide basis: X The site is underlain by dense to very stiff compacted fill overlying hard granitic rock. After planned grading, the compacted fill will be approximately 5 to 50 feet thick and bedrock will also be near or at grade. Based on existing and ultimate geologic conditions, infiltration could not be incorporated without increasing the risk of geotechnical hazards including uncontrolled water lateral migration, shrinking and swelling, induced hydro- compression of the fill and water migration within pipe zone of underground utilities. Summarize findings of studies; provide reference to studies, calculations, maps, data sources, etc. Provide narrative discussion of study/data source applicability and why it was not feasible to mitigate low infiltrationrates. 1-5 February 2016 Appendix I: Forms and Checklists ') ~ .. , ,__ ~ , '~".-'V/'-1:"'' l' ••~1f): '.',c/ ~•,a•,,,~ •. · Forµ-i J:-8 Page 4 of 4 Criteria 7 Screening Question Can Infiltration in any appreciable quantity be allowed without posing significant risk for groundwater related concerns (shallow water table, storm water pollutants or other factors)? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.3. Provide basis: Yes No X Groundwater is not located within l O feet of proposed BMP basins. The risk of storm water infiltration adversely impacting groundwater is considered negligible. Summarize findings of studies; provide reference to studies, calculations, maps, data sources, etc. Provide narrative discussion of study/ data source applicability and why it was not feasible to mitigate low infiltration rates. 8 Can infiltration be allowed without violating downstream water rights? The response to this Screening Question shall be based on a comprehensive evaluation of the factors presented in Appendix C.3. Provide basis: Researching downstream water rights and evaluating water balance issues to stream flows is beyond the scope of he geotechnical engineer. Summarize findings of studies; provide reference to studies, calculations, maps, data sources, etc. Provide narrative discussion of study/ data source applicability and why it was not feasible to mitigate low infiltration rates. Part 2 Result* If all answers from row 5-8 are yes then partial infiltration design is potentially feasible. The feasibility screening category is Partiallnfiltration. If any answer from row 5-8 is no, then infiltration of any volume is considered to be infeasible within the drainage area. The feasibility screening category is No Infiltration. No Infiltration *To be completed using gathered site information and best professional judgment considering the definition ofMEP in the MS4 Permit. Additional testing and/ or studies may be required by the City to substantiate findings. 1-6 February 2016 Runoff Factors DMAA s.f. (A) acres (C) Runoff CxA Roof 35256 0.809 0.9 0.73 Pvmt 41059 0.943 0.9 0.85 Hardscape 4705 0.108 0.9 0.10 Landscape 37345 0.857 0.1 0.09 total 118365 2.717 1.76 Composite C 0.65 DMAB s.f. (A) acres (C) Runoff CxA Roof 20380 0.468 0.9 0.42 Pvmt 42495 0.976 0.9 0.88 Hardscape 7165 0.164 0.9 0.15 Landscape 35860 0.823 0.1 0.08 total 105900 2.431 1.53 Composite C 0.63 Appendix B: Storm Water Pollutant Control Hydrologic Calculations and Sizing Methods Worksheet B.2-1 DCV DMAA 1 85th percentile 24-hr storm depth from Figure B.1-1 d= 0.64 inches 2 Area tributary to BMP (s) A= 2.72 acres 3 Area weighted runoff factor ( estimate using Appendix B.1.1 and C= 0.65 unitless 4 Trees Credit Volume TCV= cubic-feet 5 Rain barrels Credit Volume RCV= cubic-feet 6 Calculate D CV = (3630 x C x d x A) -TCV -RCV DCV= 4103 cubic-feet DMAB 1 85th percentile 24-hr storm depth from Figure B.1-1 d= 0.64 inches 2 Area tributary to BMP (s) A= 2.43 acres Ar a ight d runoff factor ( estimate using Appendix B.1.1 and C= 0.63 unitless 4 Trees Credit Volume TCV= cubic-feet 5 Rain barrels Credit Volume RCV= cubic-feet 6 Calculate D CV = (3630 x C x d x A) -TCV -RCV DCV= 3558 cubic-feet Appendix B: Storm Water Pollutant Control Hydrologic Calculations and Sizing Methods Worksheet B.5-1: Simple Sizing Method for Biofiltration BMPs DMAA ._ .. ,. ... _ lill■un-•• • • 1111 ,... • • CV after implementing retention BMPs 4,103.00 cubic-feet Partial Retention 2 Infiltration rate from Worksheet D.5-1 if partial infiltration is feasible 0.00 in/hr. 3 Allowable drawdown time for airn:regate storage below the underdrain 36 hours 4 Depth of runoff that can be infiltrated [Line 2 x Line 3] 0 inches 5 Aggregate pore space 0.4 in/in 6 Required depth of gravel below the underdrain [Line 4/ Line 5] 3 inches 7 Assumed surface area of the biofiltration BMP 5,940.00 sq-ft 8 Media retained pore storage 0.1 in/in 9 Volume retained by BMP [[Line 4 + (Line 12 x Line 8)]/12] x Line 7 891.00 cubic-feet 10 DCV that requires biofiltration [Line 1 -Line 9] 3,212.00 cubic-feet BMP Parameters 11 Surface Ponding [6 inch minimum, 12 inch maximum] 12.00 inches 12 Media Thickness [18 inches minimum], also add mulch layer thickness to this 18.00 inches line for sizing calculations 13 Aggregate Storage above underdrain invert (12 inches typical) -use 0 15.00 inches inches for sizing if the aggregate is not over the entire bottom surface area 14 Freely drained pore storage 0.2 in/in 15 Media filtration rate to be used for sizing (5 in/hr. with no outlet control; if the 1.13 in/hr. filtration rate is controlled by the outlet use the outlet controlled rate which will be less than 5 in/hr.) Baseline Calculations 16 Allowable Routing Time for sizing 6 hours 17 Depth filtered during storm [ Line 15 x Line 16] 6.78 inches 18 Depth of Detention Storage 21.6 inches [Line 11 + (Line 12 x Line 14) + (Line 13 x Line 5)] 19 Total D epth Treated [Line 17 + Line 18] 28.38 inches Ootion 1-Biofilter 1.5 times the DCV 20 Required biofiltered volume [1.5 x Line 10] 4,818.00 cubic-feet 21 Required Footprint [Line 20/ Line 19] x 12 2,037.21 sq-ft Option 2 -Store 0.75 of remaining DCV in pores and ponding 22 Required Storage (surface+ pores) Volume [0.75 x Line 10] 2,409.00 cubic-feet 23 Required Footprint [Line 22/ Line 18] x 12 1,338.33 sq-ft Footprint of the BMP 24 Area draining to the BMP 118,365.00 sq-ft 25 Adjusted Runoff Factor for drainage area (Refer to Appendix B.1 and 0.65 26 BMP Footprint Sizing Factor (Default 0.03 or an alternative) 0.03 27 Minimum BMP Footprint [Line 24 x Line 25 x Line 26] 2,308 sq-ft 28 Footprint of the BMP = Maximum(Minimum(Line 21, Line 23), Line 27) 2,308 sq-ft Check for Volume Reduction [Not applicable for No Infiltration Condition] (N/ A per form 1-8) 29 Calculate the fraction of DCV retained in the BMP [Line 9 /Line 1] 0.22 unitless 30 Minimum required fraction of DCV retained for partial infiltration 0.3 75 unitless 31 Is the retained DCV 2: 0.375? If the answer is no increase the footprint sizing □ Yes □ No XN/A Appendix B: Storm Water Pollutant Control Hydrologic Calculations and Sizing Methods Worksheet B.5-1: Simple Sizing Method for Biofiltration BMPs DMA B __ ..... "'" ....... _ 1 Remaining D CV after implementing retention BMPs 3,558.00 cubic-feet Partial Retention 2 Infiltration rate from Worksheet D.5-1 if partial infiltration is feasible 0.00 in/hr. 3 Allowable drawdown time for aggregate storage below the underdrain 36 hours 4 Depth of runoff that can be infiltrated [Line 2 x Line 31 0 inches 5 A2:2:regate pore space 0.4 in/in 6 Required depth of gravel below the underdrain [Line 4/ Line SJ 3 inches 7 Assumed surface area of the biofiltration BMP 5,160.00 sq-ft 8 Media retained pore storage 0.1 in/in 9 Volume retained by BMP [[Line 4 + (Line 12 x Line 8))/12) x Line 7 774.00 cubic-feet 10 DCV that requires biofiltration [Line 1 -Line 9) 2,784.00 cubic-feet BMP Parameters 11 Surface Ponding [6 inch minimum, 12 inch maximum] 12.00 inches 12 Media Thickness [18 inches minimwn], also add mulch layer thickness to this 18.00 inches line for sizing calculations 13 Aggregate Storage above underdrain invert (12 inches typical) -use 0 15.00 inches inches for sizing if the aggregate is not over the entire bottom surface area 14 Freely drained pore storage 0.2 in/in 15 Media filtration rate to be used for sizing (5 in/hr. with no outlet control; if the 1.1 3 in/hr. filtration rate is controlled by the outlet use the outlet controlled rate which will be less than 5 in/hr.) Baseline Calculations 16 Allowable Routing Time for sizing 6 hours 17 Depth filtered during storm [ Line 15 x Line 16) 6.78 inches 18 Depth of Detention Storage 21.6 inches [Line 11 + (Line 12 x Line 14) + (Line 13 x Line 5)) 19 Total Depth Treated [Line 17 + Line 18) 28.38 inches Option 1-Biofilter 1.5 times the DCV 20 Required biofiltered volwne [1.5 x Line 10) 4,176.00 cubic-feet 21 Required Footprint [Line 20/ Line 19) x 12 1,765.75 sq-ft Option 2 -Store 0. 75 of remaining DCV in pores and ponding 22 Required Storage (surface+ pores) Volume [0.7 5 x Line 10) 2,088.00 cubic-feet 23 Required Footprint [Line 22/ Line 18) x 12 1,160.00 sq-ft Footprint of the BMP 24 Area draining to the BMP 105,900.00 sq-ft 25 Adjusted Runoff Factor for drainage area (Refer to Appendix B.1 and 0.63 26 BMP Footprint Sizing Factor (Default 0.03 or an alternative) 0.03 27 Minimum BMP Footprint [Line 24 x Line 25 x Line 26) 2,002 sq-ft 28 Footprint of the BMP = Maximum(Minimwn(Line 21, Line 23), Line 27) 2,002 sq-ft Check for Volume Reduction [Not applicable for No Infiltration Condition] (N/ A per form 1-8) 29 Calculate tl1e fraction of DCV retained in the BMP [Line 9 /Line 1] 0.22 unitless 30 Minimum required fraction of DCV retained for partial infiltration 0.375 unitless 31 Is the retained DCV 2: 0.375? If the answer is no increase the footprint sizing □ Yes □ No XN/A BACKUP FOR PDP HYDROMODIFICATION CONTROL MEASURES [This is the cover sheet for Attachment 2.] Indicate which Items are Included behind this cover sheet: Attachment Contents Checklist Sequence Attachment 2a Hydromodification Management X Included Exhibit (Required) See Hydromodification Management Exhibit Checklist on the back of this Attachment cover sheet. Attachment 2b Management of Critical Coarse X Exhibit showing project drainage Sediment Yield Areas (WMAA Exhibit boundaries marked on WMAA is required, additional analyses are Critical Coarse Sediment Yield optional) Area Map (Required) See Section 6.2 of the BMP Design Optional analyses for Critical Coarse Manual. Sediment Yield Area Determination □ 6.2.1 Verification of Geomorphic Landscape Units Onsite □ 6.2.2 Downstream Systems Sensitivity to Coarse Sediment □ 6.2.3 Optional Additional Analysis of Potential Critical Coarse Sediment Yield Areas Onsite Attachment 2c Geomorphic Assessment of Receiving X Not performed Channels (Optional) □ Included See Section 6.3.4 of the BMP Design Manual. Attachment 2d Flow Control Facility Design and X Included Structural BMP Drawdown Calculations (Required) See Chapter 6 and Appendix G of the BMP Design Manual ATTACHMENT 2 Use this checklist to ensure the required information has been included on the Hydromodification Management Exhibit: The Hydromodification Management Exhibit must identify: □ Underlying hydrologic soil group □ Approximate depth to groundwater D Existing natural hydrologic features ( watercourses, seeps, springs, wetlands) □ Critical coarse sediment yield areas to be protected (if present) □ Existing topography □ Existing and proposed site drainage network and connections to drainage offsite □ Proposed grading □ Proposed impervious features □ Proposed design features and surface treatments used to minimize imperviousness □ Point(s) of Compliance (POC) for Hydromodification Management □ Existing and proposed drainage boundary and drainage area to each POC (when necessary, create separate exhibits for pre-development and post-project conditions) □ Structural BMPs for hydromodification management (identify location, type of BMP, and size/detail) \ d " ,, ------------------------_L__ ---------------.. -------__./ +' --. ""·.~= lc"t"· ,,'--...,_ __ -• --;· -•--·-·-c·;:-•-•-•-· -• °:cl". i :::; "'---~ ~ _'.'.~::'. _:__"".'1"°'. · H;,.. _:_ -~Lt' ~-_ --~~~~ _-~G(!'_~~- 5 : 8 ~-=,~~;ru»c -7;;,.,,---l -•' .. ~h 1----•-·--"'.'>-W• ~ -• -=rr -,+,;-~---------" C,IS'1NGct>UtJRS -•· .. . :=_::-:,~:::~, ~~;: _~·' . , ,--, ,""::' ~~:£'.~:?'"~-:': :: ,,f ::i,;.-·:-:::__ -_ --~ ~ §,=.;--·· \•' :'j.·.• '~ /./, ,/ TC FLOW.PA1H L•560' LF- ~·r . ,., . a1 -;-.1 .. '.: .:,;, ,,, j , ... 'J - T of-•cu~-<,,!-,'/.j: ,! .. i k' w -~· ,)~ •)',' .(' i,;: I ~-_;~ f ·:• ....,, ,. < ' I J/ / I ,'. •/ / ./- E / f:/,,_,,;-'_,,.(/ -, ',/,, . ! ? ",I· I . I ~~~ .JO 1.5 0 JO 50 90 ~ L===1 I SCALE: 1. = 30' PLANS PREP .... m:o BY: SPEAR & ASSOCIATES, INC . CIVIi.. ENGINEERING & LANO SURVEYING 475 PRCX>UCTION STREET, SAN UAACOS, CA 92078 Pl-;ONE {760) 7.36-20'10 f'AX (760) 7315-4866 ,,, au•::~·c-T l:IIOTaSl.Off-1 ;{.;~~;,:_JJ,, (ASrlJN0.6)1,0fRO-lal'POR()SflY MIJIQ6~('9SIX.S-. r=Jit-:s1~Ll'l'f.-~ 1 ~~~~~ I ~ ,,...,.. 1 IJRUBJ TWI04JCH 1,11,1/7DWiCE l'tAr! «oMCCWJN{Wrf.RIOlls«QFCA/DitkS#f) BJOFILTRATION BASIN T /\ Blltll•.i.-•a• ::r;~' 13 T ~-l1fCKCN.IIWlf'D WMrCww::lf'iAfC EPOl"fSE.Al.fOCATCH ~JNlfllOJAt ,• tk POFr:tl.MlD ,,.,__, CWCC"1H (OICRiOR} -----£:i==::=== Prl!flJSCD SJ'OOf DRAIN I CAICHIA$/N(PVF) ,. { ,:> __ :., .I I :. /,; ' '"'. ;, ·:",,. DRAINAGE MANAGEMENT AREA BREAKDOWN r:IWHACCJM,I.SUlfJCE!Sl'M!O. .. ,,,... IJUIJJMC ,anrx, ~7,. ~NIQ A'IDIWN,l,CCMf",A 'B'I SCJFJ#l&,llil(; 11· 11· 11· J5.256SOfT_L_1!1,_J40SOfT !.E!.!I.. ~~ ~ 4t,D59Sl)fT ] •1.mson oson ,_... DWISU!l-Mrk ~ •.ltl$SOn j 1,115son I oson JI..J45Sl)n JS.#Oson ,_s,o.son 11(,¼j:SOfT 110:,,fQISOfT I 1,510$/)fT u5.mson LL] PROJECT ADDRESS: lOTJ. ... TA.l IO<P CIR'lSBAD.CA91008 PROPERTY OWNER CARI.SBAD('l,I.KSHCWTH'oOI/Ulifil.P. ~.J.PSKCNrrJNSTRCCT.SlATr200 SAN Dt£ct), CA 92110 ca,/IACI: DCM Sl.ltrH •TCCH CONrftACTOIIS PHOIIC NO: ('79) 22.J-166) POST DK\'t:UlPMENT DWA PLAN f'OR: ~-~~~~- T)PJCAL OCTAL d' oun.cr CONNCCrlCN NOT-TO-SC.Al.£ MAINTENANCE PLATE DETAIL ATW:HfOINfCRIORIII.CTIMUOF .J6",J6"C'AfCHi!,,,SIN LOT 3, WHIPTAIL LOOP CARLSBAD. C.t. 92006 Self Mitigating Areas: SM 1,510 s.f. Landscaping ( BMP Sizing Spreadsheet V3.0 Project Name: Lot 3, Whiptail Loop Project Applicant: Tech Contractors c/o Dean Smith Jurisdiction: City of Carlsbad Parcel (APN): 209-120-02 Hydrologic Unit: Carlsbad Rain Gauge: Oceanside Total Project Area (sf): Enter Total Project Area Channel Susceptibility: High BMP Sizing Spreadsheet V3.0 Proiect Name: lot 3, Whiotail loop HydrololliC Unit: Carlsbad Project Applicant: Tech Contractors c/o Dean Smith Rain Gauge: Oceanside Jurisdiction: City of Carlsbad Total Project Area: Enter Total Project Area Parcel !APNl: 209·12CMl2 low Flow Threshold: 0.1Q2 BMPName: A BMPType: Blofiltratlon BMP Native Soil Type: D BMP Infiltration Rate (in/hr): 0.025 Areas Draining to BMP HMP Sizing Factors Minimum BMP Size Area Weighted Runoff OMA Pre Project Soil Post Project Factor Surface Area Surface Area (SF) Name Area (sf) Type Pre-Project Slope Surface Type (Table G.2-1)1 A 35,256 D Flat Roofs 1.0 0.07 2468 A 41,059 D Flat Concrete 1.0 0.07 2874 A 4,705 D Flat Concrete 1,0 0.07 329 A 37,345 D Flat Landscape 0.1 0.07 261 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BMP Tributary Area 118,365 Minimum BMP Size 5933 Proposed BMP Size• 5940 !• Assumes standard configuration Surface Ponding Depth 12.00 in Bioretention Soil Media Depth 18.00 in Fitter Coarse 6.00 in Gravel Storage Layer Depth 12 in Underdrain Offset 3.0 in t12W; 1. Runoff factors which are used for hydromodification management flow control (Table G.2-1) are different from the runoff factors used for pollutant control BMP sizing (Table B.1-1). Table references are taken from the San Diego Region Model BMP Design Manu Describe the BMP's in sufficient detail in your PDP SWQMP to demonstrate the area, volume, and other criteria can be met within the constraints of the site. BMP's must be adapted and applied to the conditions specific to the development project such as unstable slopes or the lack of available head. Designated Staff have final review and approval authority over the project design. This BMP Sizing Spreadsheet has been updated in conformance with the San Diego Region Model BMP Design Manual, April 2018. For questions or concerns please contact the jurisdiction in which your project is located. BMP Sizing Spreadsheet V3.0 Project Name: Lot 3, Whiptail Loop Hydrologic Unit: Carlsbad Project Applicant: rrech Contractors c/o Dean Smitt Rain Gauge: Oceanside Jurisdiction: City of Carlsbad Total Project Area: Enter Total Project Area Parcel (APN): 209-120-02 Low Flow Threshold: 0.1Q2 BMP Name A BMPType: Biofiltration OMA Rain Gauge Pre-developed Condition Unit Runoff Ratio DMA Area (ac) Orifice Flow -%Q2 Orifice Area Name Soil Type Slope (cfs/ac) (cfs) (in2) A Oceanside D Flat 0.571 0.809 0.046 0.66 A Oceanside D Flat 0.571 0.943 0.054 0.77 A Oceanside D Flat 0.571 0.108 0.006 0.09 A Oceanside D Flat 0.571 0.857 0.049 0.70 3.75 0.155 2.21 1.68 Max Tot. Allowable Max Tot. Allowable Max Orifice Max Orifice Head Orifice Flow Orifice Area Diameter .(feet) (cfs) (in2) (in) 0.145 0.155 2.22 1.680 Average outflow during Max Orifice Outflow Actual Orifice Area Selected surface drawdown Orifice Diameter (cfs) (cfs) (in2) (in) Drawdown (Hrs) 11.4 BMP Sizing Spreadsheet V3.0 Proiect Name: Lot 3, Whiptail Loop Hydrolooic Unit: Carlsbad Project Applicant: Tech Contractors c/o Dean Smith Rain Gauge: Oceanside Jurisdiction: City of Carlsbad Total Project Area: Enter Total Project Area Parcel (APN): 209-120--02 Low Flow Threshold: 0.1Q2 SMP Name: B BMPType: Bk>filtration BMP Native Soil Type: D BMP Infiltration Rate (In/hr): 0.025 Areas Draining to BMP HMP Sizing Factors Minimum BMP Size Area Weighted Runoff OMA Pre Project Soil Post Project Factor Surface Area Surface Area (SF) Name Area (sf) Type Pre•Project Slope Surface Type (Table G.2-1)1 B 20,380 D Flat Roofs 1.0 0.07 1427 B 42,495 D Flat Concrete 1.0 0.07 2975 B 7,165 D Flat Concrete 1.0 0.07 502 B 35,860 D Flat ~ndscape 0.1 0.07 251 o o o o o 0 o o o o o o o o o o o o o o o o BMP Tributary Area 105,900 Minimum BMP Size 5154 Proposed BMP Size• 5160 • Assumes standard configuration Surface Ponding Depth 12.00 in Bioretention Soll Media Depth 18.00 in Filter Coarse 6.00 in Gravel Storage Layer Depth 12 in Underdrain Offset 3.0 in Notes: 1. Runoff factors which are used for hydromodification management flow control {Table G.2·1) are different from the runoff factors used for pollutant control BMP sizing (Table 8.1·1). Table references are taken from the San Diego Region Model BMP Design Manu Describe the BMP's in sufficient detail in your POP SWQMP to demonstrate the area, volume, and other criteria can be met within the constraints of the site. BMP's must be adapted and applied to the conditions specific to the development project such as unstable slopes or the lack of available head. Designated Staff have final review and approval authority over the project design. This BMP Sizing Spreadsheet has been updated in conformance with the San Diego Region Model BMP Design Manual, April 2018. For questions or concerns please contact the jurisdiction in which your project is located. BMP Sizing Spreadsheet V3.0 Project Name: Lot 3, Whiptail Loop Hydrologic Unit: Carlsbad Project Applicant: Tech Contractors c/o Dean Smith Rain Gauge: Oceanside Jurisdiction: City of Carlsbad Total Project Area: Enter Total Project Area Parcel (APN}: 209-120-02 Low Flow Threshold: 0.1Q2 BMP Name B BMPType: Biofiltration DMA Rain Gauge Pre-developed Condition Unit Runoff Ratio DMA Area (ac} Orifice Flow -%Q2 Orifice Area Name Soil Type Slope (cfs/ac} (cfs} (in2} B Oceanside D Flat 0.571 0.468 0.027 0.38 B Oceanside D Flat 0.571 0.976 0.056 0.79 B Oceanside D Flat 0.571 0.164 0.009 0.13 B Oceanside D Flat 0.571 0.823 0.047 0.67 3.75 0.139 1.98 1.59 Max Tot. Allowable Max Tot. Allowable Max Orifice Max Orifice Head Orifice Flow Orifice Area Diameter (feet) (cfs} (in2) (in) 0.130 0.139 1.99 1.590 Average outflow during Max Orifice Outflow Actual Orifice Area Selected surface drawdown Orifice Diameter (cfs} (cfs} (in2} (in} Drawdown (Hrs} 11.1 Structural BMP Maintenance Information Use this checklist to ensure the required information has been included in the Structural BMP Maintenance Information Attachment: Preliminary Design/Planning/CEQA level submittal: Attachment 3 must identify: X Typical maintenance indicators and actions for proposed structural BMP(s) based on Section 7.7 of the BMP Design Manual Final Design level submittal: Attachment 3 must identify: o Specific maintenance indicators and actions for proposed structural BMP(s). This shall be based on Section 7.7 of the BMP Design Manual and enhanced to reflect actual proposed components of the structural BMP(s) o How to access the structural BMP(s) to inspect and perform maintenance o Features that are provided to facilitate inspection (e.g., observation ports, cleanouts, silt posts, or other features that allow the inspector to view necessary components of the structural BMP and compare to maintenance thresholds) o Manufacturer and part number for proprietary parts of structural BMP(s) when applicable o Maintenance thresholds for BMPs subject to siltation or heavy trash(e.g., silt level posts or other markings shall be included in all BMP components that will trap and store sediment, trash, and/or debris, so that the inspector may determine how full the BMP is, and the maintenance personnel may determine where the bottom of the BMP is . If required, posts or other markings shall be indicated and described on structural BMP plans.) o Recommended equipment to perform maintenance o When applicable, necessary special training or certification requirements for inspection and maintenance personnel such as confined space entry or hazardous waste management OPERATION & MAINTENANCE (O&M) PLAN 1. Contents 1. PROJECT DESCRIPTION .................................................................................................. 1 2. OPERATION & MAINTENANCE (O&M) PLAN ........................................................... 1 3. Operation & Maintenance of BMP'S .................................................................................. 1 A. Training .............................................................................................................. 2 B. Landscaping ....................................................................................................... 2 C. Irrigation System ................................................................................................ 5 D. Roof Drains ........................................................................................................ 5 E. Trash Storage Areas .......................................................................................... 5 F. Storm Water Conveyance System Stenciling and Signing ................................. 5 G. Structural BMP: Biofiltration .............................................................................. 7 H. Outlet Structures ................................................................................................ 8 I. Vector Control Owner Responsibilities .................................................................. 8 ATTACHMENTS Al. Inspection & Maintenance Schedule Bl. Cost Estimate Cl. BMP Training Log D1. Inspection & Maintenance Log -i- 1. PROJECT DESCRIPTION Proposed land use is for a commercial development with 3 buildings, a parking lot, underground utilities, covered trash enclosures, landscaping, and biofiltration for stormwater treatment. 2. OPERATION & MAINTENANCE (O&M) PLAN This document has been prepared in compliance with the San Diego Regional Water Quality Control Board requirements and in accordance with requirements set by the City. A Storm Water Quality Management Plan (SWQMP) has been prepared for the project. It identifies the specific Best Management Practices (BMPs) required for the project. Refer to this project's SWQMP for additional information on BMPs. Proper maintenance of the project BMP's is required for their intended and effective function. This O&M Plan provides operation and maintenance procedures for the BMPs designated in the SWQMP. It includes procedures to be followed for inspection and maintenance of the BMPs, instructions for documenting the work performed, record keeping, and outlining the requirement and procedures for training of personnel involved in the process. 3. Operation & Maintenance of BMP'S It shall be the responsibility of the "Owner or Designated Responsible Party" to maintain and to train all employees for the maintenance and operation of all BMPs, to achieve the maximum pollutant reduction they are designed for, as addressed in the approved Project's SWQMP. The following schedule of O&M' s must be followed to satisfy the Conditions of Concern and the Pollutants of Concern as addressed in the approved Project's SWQMP. This schedule shall include periodic inspections of all Source Control and Treatment Control BMP's. All maintenance records for training, inspection and maintenance shall be retained and provided to the city upon request. The owner may also be required to provide to the City, as part of the maintenance and operation agreement an executed access easement that shall be binding on the land throughout the life of the project. Responsible Party for O&M and For Training Tech Contractors c/o Dean Smith 3575 Kenyon St., Suite 200, San Diego, CA 92110 619-223-1663 dean@techbilt.com The Designated Responsible Party will be responsible for ensuring that individuals involved in O&M activities, including but not limited to contractors and new owners, will be trained according to the training program herein, Additionally, upon any future sale of the property, the Owner will be responsible for ensuring that the new Designated Responsible Party is familiar with the contents of the plan and the requirements for the routine inspection, routine and non-routine maintenance and 1 record keeping tasks as described herein. All parties involved in the O&M activities will be required to read this plan. A. Training Personnel training is an important component of the implementation of this O&M Plan. The employee training program may consist of a meeting with any new owners, Designated Responsible Party or contractor/employees involved in the O&M activities to review the contents of this plan and to physically tour the facility to observe the BMPs and describe O&M requirements for each BMP. The Designated Responsible Party will implement the training program. All new contractors involved in landscape and/or facility maintenance at the site shall receive training within 30-days of hire and shall receive updated annual training. Maintenance contractor shall verify staff training annually. The Designated Responsible Party shall be responsible for documenting all training activities and for maintaining records related to training. Forms for documentation of training are included in Attachment C 1 of this plan. Training records must be shall be retained and provided to the city upon request. B. Landscaping Operational and maintenance needs include: • Vegetation management to maintain adequate drainage and to limit habitat for mosquitoes, rodents and other disease-carrying vectors. :) • Parking lot sweeping. • Animal and vector control (any method to limit or eradicate the mammals, birds, insects or other arthropods which transmit disease pathogens). • Periodic sediment removal to optimize performance. • Trash, debris, grass trimmings, tree pruning, and leaf collection and removal to prevent obstruction of landscape areas so as not to prohibit their use as a BMP. • Monitoring irrigation equipment. • Removal of standing water, which may contribute to the development of aquatic plant communities or mosquito breeding areas. • Preventive maintenance on sampling, flow measurement, and associated BMP equipment and structures. • Erosion and structural maintenance to prevent the loss of soil and maintain the performance of all landscaping. Inspection Frequency The facility will be inspected and inspection visits will be completely documented: • Once a month at a minimum. • After every large storm (after every storm monitored or these storms with more than 0.50 inch of precipitation.) • On a weekly basis during extended periods of wet weather. 2 c· Inspect for proper irrigation and fertilizer use, and ensure that all landscaped areas have minimum of 80% coverage. Visual Inspection as part of landscape maintenance • Inspect before and after the rainy season (Rainy season (Oct. 1 to April 30)). Aesthetic Maintenance The following activities will be included in the aesthetic maintenance program: Grass Trimming: Trimming of grass will be done on all landscaped areas, around fences, at the inlet and outlet structures, and sampling structures. Weed Control. Weeds will be removed through mechanical means. Herbicide shall not be used because these chemicals will impact the water quality monitoring. Functional Maintenance Functional maintenance has two components: • Preventive maintenance • Corrective maintenance Preventive Maintenance Preventive maintenance activities to be instituted for landscaped areas are: • • • • • • Grass Mowing: Vegetation seed, mix within the landscaped areas, are to be designed to be kept short to maintain adequate drainage and to limit the development of faunal habitats. Prohibitive dumping placards . Trash and Debris: During each inspection and maintenance visit to the site, debris and trash removal will be conducted to reduce the potential for inlet and outlet structures and other components from becoming clogged and inoperable during storm events. Sediment Removal: Sediment accumulation, as part of the operation and maintenance program at of landscaped areas, will be monitored once a month during the dry season, after every large storm (0.50 inch), and monthly during the wet season. Specifically, if sediment reaches a level at or near plant height, or could interfere with flow or operation, the sediment will be removed. If accumulation of debris or sediment is determined to be the cause of decline in design performance, prompt action (i.e., within ten working days) will be taken to restore the landscaped areas to design performance standards. Actions will include using additional fill and vegetation and/or removing accumulated sediment to correct channeling or ponding. Characterization and Appropriate disposal of sediment will comply with applicable local, county, state, or federal requirements. The landscaped areas will be re-graded, if the flow gradient has changed, and then replanted with sod. Removal of Standing Water: Standing water must be removed if it contributes to the development of aquatic plant communities or mosquito breeding areas. Fertilization and Irrigation: The vegetation seed mix is to been designed so that fertilization and irrigation is to be kept at a minimum. 3 • Elimination of Mosquito Breeding Habitats. The most effective mosquito control program is J one that eliminates potential breeding habitats. Corrective Maintenance Corrective maintenance is required on an emergency or non-routine basis to correct problems and to restore the intended operation and safe function of all landscaped areas. Corrective maintenance activities include: Removal of Debris and Sediment: Sediment, debris, and trash, which impede the hydraulic functioning of landscaping and prevent vegetative growth, will be removed and properly disposed. Temporary arrangements will be made for handling the sediments until a permanent arrangement is made. Vegetation will be re-established after sediment removal. Structural Repairs: Once deemed necessary, repairs to structural components of landscaping will be done within 10 working days. Qualified individuals (i.e., the designers or contractors) will conduct repairs where structural damage has occurred. Embankment and Slope Repairs: Once deemed necessary, damage to the embankments and slopes of landscaped areas will be repaired as soon as possible, and within IO working days maximum. Erosion Repair: Where a reseeding program has been ineffective, or where other factors have created erosive conditions (i.e., pedestrian traffic, concentrated flow, etc.), corrective steps will be taken to prevent loss of soil and any subsequent danger to the performance and use of landscaped areas as BMPs. There are a number of corrective actions than can be taken. These include erosion control blankets, riprap, sodding, or reduced flow through the area. Designers or contractors will be consulted to address erosion problems if the solution is not evident. J Elimination of Animal Burrows Animal burrows will be filled and steps taken to remove the animals if burrowing problems continue to occur (filling and compacting). If the problem persists, vector control specialists will be consulted regarding removal steps. This consulting is necessary as the threat of rabies in some areas may necessitate the animals being destroyed rather than relocated. If the BMP performance is affected, abatement will begin. Otherwise, abatement will be performed annually in September. General Facility Maintenance: In addition to the above elements of corrective maintenance, general corrective maintenance will address the overall facility and its associated components. If corrective maintenance is being done to one component, other components will be inspected to see if maintenance is needed. Maintenance Frequency The Inspection & Maintenance Schedule included in enclosed Attachment A 1 for all BMPs lists the schedule of maintenance activities to be implemented. Debris and Sediment Disposal Waste generated onsite is ultimately the responsibility of the Owner. Disposal of sediments, debris, and trash will comply with applicable local, county, state, and federal waste control programs. Hazardous Waste 4 ( Suspected hazardous wastes will be analyzed to determine disposal options. Hazardous wastes generated onsite will be handled and disposed of according to applicable local, state, and federal regulations. A solid or liquid waste is considered a hazardous waste if it exceeds the criteria listed in the CCR, Title 22, Article 11. C. Irrigation System Inspection Frequency and Procedure The Irrigation system shall be checked each week as a minimum. The following items shall be checked to insure that they are functioning properly: • Shut-off devices • Pressure drop sensors • Moisture sensors • All piping and sprinkler heads to insure there are no leaks and that proper water spread is maintained. • All flow reducers. • Check for overspray/runoff D. Roof Drains All roof drains shall be inspected Prior to August 31 of each year to ensure that they are clean and free from trash and in good repair. They shall be flushed and any leaks or damages piping shall be either replaced or repaired. Where roof drains flow onto grass areas splash structures and or rock rip-rap shall be maintained so the flow from the roof drains do not cause erosion or damage to the grass area. During the rain season roof drains shall be inspected weekly and after each rain storm to insure that there is no trash and or silt build up that will restrict the run-off flow from the roof. All trash and/or silt build up shall be removed immediately. • It is not permissible to directly connect roof drains into a drain system. • Roof drain downspouts shall discharge runoff to a landscaped area, and to allow the runoff to flow through landscape, prior to entering a private yard drain system. E. Trash Storage Areas All trash storage areas shall be inspected daily to insure that they are clean from trash. Also the following shall be inspected annually before and after the rainy season (Oct. 1 to April 30). • Pavement is in good repair. • Drainage will not run-off onto adjacent areas. • That they remain screened or walled to prevent off-site transport of trash. • That all lids are closed and/or awnings are in good repair to minimize direct precipitation. F. Storm Water Conveyance System Stenciling and Signing 5 ■ Signage/stenciling are to be inspected for legibility and visual obstruction and shall be repaired J and cleared of any obstruction within 5 working day of inspection. ■ Inspection Frequency: Semi-annually, and monthly during rainy season. 6 G. Structural BMP: Biofiltration Vegetated Infiltration or Filtration BMP Maintenance Indicators and Actions for Vegetated BMPs Typical Maint~nance lndicator(s) Maintenance Actions for Vegetated BMPs Accumulation of sediment, litter, or Remove and properly dispose of accumulated materials, without debris damage to the vegetation. Poor vegetation establishment Re-seed, re-plant, or re-establish vegetation per original plans. Overgrown vegetation Mow or trim as appropriate, but not less than the design height of the vegetation per original plans when applicable (e.g. a vegetated swale may require a minimum vegetation height). Erosion due to concentrated irrigation Repair/ re-seed/ re-plant eroded areas and adjust the irrigation flow system. Erosion due to concentrated storm Repair/ re-seed/ re-plant eroded areas, and make appropriate water runoff flow corrective measures such as adding erosion control blankets, adding stone at flow entry points, or minor re-grading to restore proper drainage according to the original plan. If the issue is not corrected by restoring the BMP to the original plan and grade, The City must be contacted prior to any additional repairs or reconstruction. Standing water in vegetated swales Make appropriate corrective measures such as adjusting irrigation system, removing obstructions of debris or invasive vegetation, loosening or replacing top soil to allow for better infiltration, or minor re-grading for proper drainage. If the issue is not corrected by restoring the BMP to :11e original plan and grade, iCitv sta§ must be contacted prior to any additional repairs or reconstruction. Standing water 1n bioretention, Make appropriate corrective measures such as adjusting irrigation biofiltration with partial retention, or system, removing obstructions of debris or invasive vegetation, biofiltration areas, or flow-through clearing underdrains (where applicable), or repairing/ replacing planter boxes for longer than 96 hours clogged or compacted soils. following a storm event"' Obstructed inlet or outlet structure Clear obstructions. Damage to structural components such Repair or replace as applicable. as weirs, inlet or outlet structures "These BMPs typically include a surface ponding layer as part of their function which may take 96 hours to drain following a storm event. 7 Inspection Frequency The facility will be inspected and inspection visits will be completely documented: ■ Once a month at a minimum. ■ After every large storm (after every storm monitored or these storms with more than 0.50 inch of precipitation.) ■ On a weekly basis during extended periods of wet weather. Maintenance is needed if vegetation height is greater than 5" (height shall be kept between 2" and 5"); if there is standing water; if debris are present or if sedimentation is occurring at the vegetation height; ensure that all landscaped areas have minimum of 80% coverage and that no animal burrows are present. Visual Inspection as part of landscape maintenance • Inspect before and after the rainy season (Rainy season (Oct. I to April 30)). H. Outlet Structures All outlet structures shall be kept functional at all times. Routine inspection and corrective maintenance shall include removal of trash sediment and debris and repair of any structural damage or clogging of orifice outlets. The minimum maintenance frequency shall be Prior to August 31 each year, weekly during rainy season or within 24 hours prior to rain forecasts. I. Vector Control Owner Responsibilities VECTOR MANAGEMET CONTROL REQUIREMENTS Any method to limit or eradicate the mammals, birds, insects or other arthropods which transmit disease pathogens. Management of mosquitoes and other vectors in stormwater management structures, such as Bioretention Facilities and Best Management Practices, is critical for protecting public health. In order to implement vector controls including minimizing the risk for mosquito-borne disease transmission, It is the responsibility of the Owner to regularly maintain the outlet structures and monitor the site after every storm event to ensure that the system (comprising of above and below ground storage facilities) is dewatered in less than 72 hours. Otherwise the owner will be required to implement a vector control plan in accordance with California Department of Public Health. ■ Maintain all drainage inlets and outlets trash free; remove silt; make sure to clear any standing water after 72-hours of ponding. Vector Control Resources: l. F of San Diego vector educational brochures please reference the following website: http://www.sdcounty.ca.gov/deh/pests/vector disease.html 2. Please contact the County of San Diego vector control program with specific questions or concerns. 8 ATTACHMENT "Al" INSPECTION & MAINTENANCE SCHEDULE PREVENTATIVE MAINTENANCE AND ROUTINE INSPECTION TYPE BMP Routine Action Maintenance Maintenance MAINTENANCE Indicator Freauencv ACTIVITY Landscaping & Proper irrigation Less than 80% Each year as Re-plant. Repair irrigation & Fertilizer. coverage needed and once Irrigation system during rainy season within 5-days. (Oct. 1 to April 30) Trash storage Trash free and Visual Daily inspection Remove trash and areas removal of silt Inspection silt Daily. Roof drain Trash free and Silt build up of Each year routinely Remove all trash removal of silt, more than 1" no as needed. and silt and repair sedimentation & trash any damage to Debris roof drains, Bioretention -Trash free and Silt build up of Monthly during rainy Remove trash and Biofiltration removal of silt. more than 2" no season, and silt -repair and Facilities Clear Clogged trash, after Storm Event reseed exposed outlets and Exposed soils, areas, maintain Standing Water. dead grass height so as vegetation, not be shorter ponded water, than 2" or higher and excessive than 5" remove all vegetation ponded water (see TC-30) weekly inspections, (See TC-30) Storm Water Must be legible Fading of paint Semi-annually each Repaint stenciling Conveyance at all times and or illegible year & monthly and/or replace system have a clear letters or during rainy season signs Stenciling & view. Signing Outlet Must be kept Silt, debris, Weekly during rainy Silt, debris, trash Structures functional at all trash season or within 24 accumulation and times. Clear accumulation, hours prior to rain repair any Clogged outlets Ponding Water forecasts. structural damage and Standing to the outlet Water. structures. 9 SITE-SPECIFIC REQUIREMENTS All slopes and landscaped areas are to have a minimum coverage of 80% All trash storage areas to be free from trash and silt at all times All Roof to be free from trash and silt and in good repair All bio-filters to be free from trash and silt at all times, grass area to be free from exposed soil and maintained to proper height, removal of any ponding of water for more than 72 hours. Appies to all stenciling and signs All outlet structures shall be kept functional at all times. ATTACHMENT "B1" ..., Annual Estimate to Maintain all BMPs Annual 10-Year Landscaping & Biofiltration Maintenance of landscaping and bio-filters is already included in the property management responsibilities. Additional cost: $400 $4,000 Irrigation System: Inspection and maintenance of the irrigation system is already included in the property management responsibilities, Additional cost: $100 $1,000 Roof Drains: Roof drain inspection and maintenance is already included in the property management responsibilities. Training: Once a year & training of new employees within their first week of employment. $100 $1,000 Stormdrain Signage (As needed or every 2 years) $100 $1,000 :) Trash Storage Areas: Inspection of trash storage area & maintenance to those areas is already included in the property management responsibilities. Additional cost: $50 $500 Total Estimated Annual Cost to Maintain BMPs $750 $7,500 10 ATTACHMENT "C1" BMP TRAINING LOG Personnel Date Type of Training Trained Trainer MO/Day/Yr 11 ATTACHMENT "D1" INSPECTION AND MAINTENANCE LOG Name of Date Repair made and BMP TYP & DATE Person Description of BMP Condition/ Description repair Description repair required if made and by LOCATION M/D/Y Inspecting any whom A 12 ATTACHMENT 3 ATTACHMENT 4 City standard Single Sheet BMP (SSBMP) Exhibit [Use the City's standard Single Sheet BMP Plan.] ------ -----------------------------------------------------------------------------------------------------EX. 12" VPVC WATER EX. 12~ PVC WATER -- ---•s--- ----- -~ ✓~ ;:, 30 15 0 30 60 90 SCALE: 1 " -30' PLANS PREPARED BY: SPEAR & ASSOCIATES, INC. CIVIL ENGINEERING & LAND SURVEYING 475 PRODUCTION STREET, SAN MARCOS, CA 92078 PHONE (760) 736-2040 FAX (760) 736-4866 WWW.SPEARINC.NET --------------· ------------------- ' EX. 16" CMLC WA"TER WHIPTAIL LOOP 18 EX. 8" PV~ SEWER * MINIMUM CURB DEPTH IS 12 INCHES; CURBS SHOULD BE VERTICAL ELBOW DOWELED TWO FEET INTO ADJACENT PCC PAVEMENT WITHIN 10 FEET OF THE 8/0RLTRATION BASIN. 3• HARDWOOD MULCH " ' EX. SMH ~ MAINTENANCE CLEAN-OUT CATCH BASIN EMERGENCY OVERFLOW STORM DRAIN STENCIL 50-13 3.oo'(MIN.} BENCH j WHEN NEXT TO A SLOPE ~✓-'=-,1.,-------- :;,; c::, s;;,"= ~ c§ -ffl C,"' cl e: -BASIN TOP (MIN.) (TO REMAIN CLOSED AT ALL TIMES) 6" MIN. FROM F.S. OF BASIN 6" P.C.C. CURB PER SDRSD G-1 1% MIN- TYPICAL DETAIL & OUTLET CONNECTlON NOT-TO-SCALE 17 s s: I s ' >,t EX. 16~ CMLC WATER EX. s; PVC SEWER s COREDR/ll KEYHOLE TYPE OPENING FOR MAINTENANCE PLATE REMOVAL WITHOUT REMOVING THE BOLTS -..i-½"x4" STAINLESS STEEL WEDGE ANCHOR BOLT 12x12" PLATE ¾ • THICK GAL VAN/ZED MAINTENANCE PLATE / ~ ---._, EPOXY SEAL TO CATCH t;:;' BASIN INTERIOR WALL ( l., lg \_-+-6" DIA. PERFORATED 8 \ ~11 8 PVC UNDERDRAIN , / CONNECTION (EXTERIOR} ORIFICE DRILLED THROUGH MAINTENANCE PLATE @ UNDERDRAIN CONNECTION. A= 1.68: B= 1.59" MAINTENANCE PLATE DETAIL ATTACH TO INTERIOR INLET WALL OF 36"x36" CATCH BASIN DRAINAGE MANAGEMENT AREA BREAKDOWN DRAINAGE AREA SURFACE SYMBOL DRAINAGE AREA JI' DRAINAGE AREA 'B' SELF MmGAT!NG SOil TYPE BUILDING ROOFTOP PARKING/DRIVE AISLE IMPERVIOUS AREA HARSCAPING/SIOEWALK LANDSCAPING OMA SUB-AREA: TOTAL SITE AREA: ~ 35,256 SQ FT [. • ' ,, I 4,705 SQ FT 118,365 SQ FT 20,380 SQ FT 0 SQ FT 42,495 SQ FT 0 SQ FT 7,165 SQ FT 0 SQ FT 35,860 SQ FT 1,510 SQ FT 105,900 SQ FT 1,510 SQ FT 225,775 SQ FT --------- LEGEND OF SYMBOLS ---------PROPERTY LINE ( [II}------- --- STREET CENTERLINE EXISTING CONTOURS DIRECTION OF DRAINAGE DRAINAGE AREA DRAINAGE MANAGEMENT AREA DESIGNA TIGN LONGEST FLOW PATH PROPOSED STURM DRAIN 8. CATCH BASIN (PVT> PROJECT ADDRESS: LOT J, WHIPTAIL LOOP CARLSBAD, CA 92008 PROPERTY OWNER CARLSBAD OAKS NORTH VENTURES LP. ADDRESS: 3575 KENYON STREET, SUITE 200 SAN DIEGO, CA 92110 CONTACT: DEAN SMITH @TECH CONTRACTORS PHONE NO: (619} 223-1663 I SH1EET I CITY OF CARLSBAD I SH1EETS I ::::::::=:=::::'...:::::=:::::E:::N:::G:::IN::::E=:E::::R:::IN:::G==:D:::E:::::P:::::AR::::T:::::M::::E:::N:::::T=--:=::. POST DEVELOPMENT DMA PLAN FOR: LOT 3, WHIPTAIL LOOP CARLSBAD, CA 92008 DRAWING NO. POST