Loading...
HomeMy WebLinkAboutCUP 00-20; WESTBLUFF PLAZA PCS; Site Plan-JOs;p;o 'c.i. "' -- \i) ~ " N "'<: ·\j i r{ li I :.) (.:) --J °'J <£) ~ ~-\J) ::::i lU u ~;; APPilOVE.D AN EASEMENT FOR UNDERGROUND UTILITIES AND -- RIGHTS INCIDENTAL THERETO GRANTED TO THE COSTA REAL MUNICPAL WATER DISTRICT RECORDED MARCH 28, 1980 AS INSTRUMENT 80-107961, OF OFFICIAL RECORDS. REFER TO EASEMENT 14 ON THE TITLE REPORT (SHOWN DASHED) I I I DOVE LANE ( ' I I ' I I I L _ _j C I 1() 1,~ ,-1Z 10 I \\\\ EXISTING CONCRETE CURB, GUTTER & SIDEWALK TO REMAIN II \I I\ II II " . \I I ·------. . I\ -----.11 I \l II 1- PROPOSED PACIFIC BELL WIRELESS ANTENNAS FACADE 1-1\ MOUNTED TO EXISTING BUILDING WALL WITH LNA UNITS I \ EXISTING ASPHALT PARKING ____"\, \ AREA TO REMAIN (TYPICAL) \ \\, _! -. c-::_-::_-::_ ___ > EXISTING DRIVEWAY I I MOUNTED IN ATTIC SPACE BEHIND ANTENNAS. ANTENNAS, ,___J 1,? ----) ANTENNA MOUNTS AND ALL EXPOSED CABLE SHALL BE c----" PAINTED TO MATCH EXISTING ADJACENT SURFACES. -•• _ _ _______ I_II/,_ SEE EXTERIOR ELEVATIONS SHEET A-2 \ _" I, I I I ' I \ \11 ,I II II \I 1\ II II II I \I I 1\ EXISTING 800 AMP MAIN SWITCHGEAR IN ELECTRICAL CLOSET WITH 120/208V, 3 PHASE, 4 WIRE I -----------r· -. ------\II I ii I II POWER SOURCE (POWER SERVICE CONNECTION) I " EXISTING PACIFIC BELL MPOE IN ELECTRICAL CLOSET (TELCO SERVICE CONNECTION) I I I \ // y" AN EASEMENT FOR UNDERGROUND UTILITIES AND ---" I RIGHTS INCIDENTAL THERETO GRANTED TO THE COSTA I REAL MUNICPAL WATER DISTRICT RECORDED MARCH 28, 1980 AS INSTRUMENT 80-107961, OF OFFICIAL RECORDS. REFER TO EASEMENT 14 ON THE TITLE REPORT (SHOWN DASHED) I ' II \I 1\ \11 1\ \I I\ 111 I I 11\ \\-"~ \\,_./ / \ \ /__,II I I // \\ \ \ II I I II I \\ \, \ \\ \ \ ~ II I I W \I I \ © ~ i\ 1 1 I ~ II 1 I ,,,c, \\ \ \ ----/-~ ~ ~ \1 I .,/~_.., 0.... 1\ ~Y \ 0.. II \ \ <C ~------\ \ \ /.....✓-------\1 \ ~----, DIMENSION NOTE: 1 1\ 1 1 II l \ DIMENSIONS SHOWN FROM PROPERTY LINES ARE -~-\\ 1 r----j APPROXIMATE AND ARE SHOWN FOR GENERAL \ Ii 1 •;,· REFERENCE. REFER TO DIMENSIONS ON SHEET \_ II V\ A-1 FOR EQUIPMENT LOCATION REFERENCED TO , 1111 __ ./ 11 1 EXISTING FEATURES IN THE IMMEDIATE VICINITY OF 11 1i'1 / 1 PROPOSED WORK I II \ 1//11\1 \\ I, II \ II I AN EASEMENT FOR UNDERGROUND UTILITIES AND __ /I 1111 \1 RIGHTS INCIDENTAL THERETO GRANTED TO THE COSTA 1\ \1\ 11 REAL MUNICPAL WATER DISTRICT RECORDED APRIL 15, 11 1 SECTOR A 350' .. 1982 AS INSTRUMENT 82-105098, OF OFFICIAL I \I 1 RECORDS. REFER TO EASEMENT 15 ON THE TITLE 1\ 1 1 REPORT (SHOWN DASHED) \ '-i\ \ 11 N 89" 45' 46" W ' I I I I I ' I \_ \ ' ' II I \I I Iii I II 11 II I \I I 11 I I I I I ' I I' I ,,\ I \\ \ \\ \ \, \ '\\ \ '\, \ ' ' ' ' / 188.45' \ ', '',, : ~' ----------------------------~ I I ' THIS lS THE APPROVED TENTATIVE MAP/SITE \ I PLAN PER CONDITION NG. tf_fri . ,ANNING COMM!SSJON RESOLUT!O I NO. , ALGA ROAD i'.,, 'v-. ra/aJ(o, E ering Dept. -Date I I ' / / ,/ --// .SECTOR 90' 0) 0) w b 0 z B EXISTING ADJACENT RETAIL SHOPS & BUSINESS FACILITIES (TYPICAL) PROPERTY LINE (TYPICAL) PROPOSED PACIFIC BELL WIRELESS ANTENNAS AND LNA UNITS MOUNTED INSIDE NEW DORMER STRUCTURE. NEW DORMER SHALL MATCH EXISTING BUILDING IN COLOR AND TEXTURE AND EXISTING DORMER IN SCALE AND DETAIL. SEE ROOF PLAN SHEET A-1 PROPOSED PACIFIC BELL WIRELESS ANTENNAS FACADE MOUNTED TO EXISTING BUILDING WALL WITH LNA UNITS MOUNTED IN ATTIC SPACE BEHIND ANTENNAS. ANTENNAS, ANTENNA MOUNTS AND ALL EXPOSED CABLE SHALL BE PAINTED TO MATCH EXISTING ADJACENT SURFACES. SEE EXTERIOR ELEVATIONS SHEET A-2 PROPOSED PACIFIC BELL WIRELESS BTS EQUIPMENT CABINETS ON A CONCRETE PAD ON GRADE INSIDE AN 8' -0" HIGH SLUMP BLOCK ENCLOSURE (SHOWN SHADED). SEE ROOF PLAN & BTS EQUIPMENT PLAN SHEET A-1 --EXISTING COX COMMUNICATIONS EQUIPMENT ENCLOSURE TO REMAIN EXSITING LANDSCAPING TO REMAIN (TYPICAL) EXSITING PLAZA AREA TO REMAIN -EXSITING ADJACENT BUILDING TO REMAIN BENCHMARK: STREET SURVEY WELL MONUMENT AT THE INTERSECTION OF EL CAMINO REAL AND ALGA ELEVATION 89.45' AT MEAN SEA LEVEL (NGVD BOUNDARY NOTE: ROAD 1929) THIS SITE PLAN WAS DEVELOPED FROM THE RECORD PLAT PROVIDED WITH THE TITLE REPORT AND WAS NOT SURVEYED IN ITS ENTIRETY. FOR DETAILED DATA IN THE VICINITY OF THE PROPOSED PROJECT, SEE SHEETS A-1 AND C-1 ELSEWHERE IN THESE PLANS SITE PLAN SCALE: 1• • 60' GENERAL SPECIFICATIONS 1. THE LATEST EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201 "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" ARE INCLUDED IN THESE SPECIFICATIONS AS IF COMPLETELY REPRODUCED HEREIN. 2. THIS FACILITY IS AN UNOCCUPIED PCS TELECOMMUNICATIONS SITE AND IS EXEMPT FROM DISABLED ACCESS REQUIREMENTS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS PARTICIPATING SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL FIELD CONDITIONS AFFECTING THE PROPOSED PROJECT INCLUDING DEMOLITION, ELECTRICAL, MECHANICAL AND STRUCTURAL INSTALLATIONS, AS WELL AS WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS AND SHALL CONFIRM THAT THE PROJECT CAN BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. SHOULD ANY ERRORS, OMISSION, OR DISCREPANCIES BE FOUND, THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT IN WRITING. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL INCLUDE THE MORE COSTLY OR EXTENSIVE WORK IN THE BID, UNLESS SPECIFICALLY DIRECTED OTHERWISE. IF A DISCREPANCY EXISTS AND THE PROJECT MANAGER AND ARCHITECT ARE NOT NOTIFIED, THE GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL COSTS INCURRED TO REPAIR OR CORRECT ALL PROBLEMS THAT RESULT. 4. DRAWINGS SHALL NOT BE SCALED. THESE DRAWINGS ARE INTENDED TO BE DIAGRAMMATIC ONLY. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS, OR BEGIN ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAS BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 5. THE CONTRACTOR SHALL INCLUDE IN HIS OR HER BID ALL MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE THE WORK AS INDICATED OR IMPLIED BY THESE DRAWINGS. 6. CONTRACTOR SHALL NOTIFY THE PACIFIC BELL WIRELESS PROJECT MANAGER, THE PROPERTY OWNER AND THE ARCHITECT IF ANY DETAILS ARE CONSIDERED IMPRACTICAL, UNSUITABLE, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO ANY DETAIL. DETAILS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 7. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 8. THE CONTRACTOR SHALL VERIFY ALL TELEPHONE & RADIO EQUIPMENT LAYOUTS, SPECIFICATIONS, PERFORMANCE, INSTALLATION AND FINAL LOCATIONS WITH PACIFIC BELL WIRELESS PROJECT MANAGER PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH ERICSSON RADIO SYSTEMS. 9. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE PACIFIC BELL WIRELESS PROJECT MANAGER AND THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK. 10. THE CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO PACIFIC BELL WIRELESS 11. THE CONTRACTOR SHALL PROVIDE CONTINUOUS SUPERVISION WHILE ANY SUBCONTRACTORS OR WORKMEN ARE ON THE SITE AND SHALL SUPERVISE AND DIRECT ALL WORK, USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 12_ WORKMANSHIP THROUGHOUT SHALL BE OF THE BEST QUALITY OF THE TRADE INVOLVED, AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM REFERENCE STANDARDS FOR QUALITY AND PROFESSIONAL CONSTRUCTION PRACTICE: NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION O'HARE INTERNATIONAL CENTER 10255 W. HIGGENS ROAD, SUITE 600 ROSEMONT, IL 60018 SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION 4201 LAFAYETTE CENTER DRIVE CHATILLY, VA 22021-1209 ITLP INTERNATIONAL INSTITUTE FOR LATH AND PLASTER 820 TRANSFER ROAD ST, PAUL, MN 55114-1406 13. INSTALL ALL EQUIPMENT AND MATERIALS PER THE LATEST EDITION OF THE MANUFACTURER'S INSTALLATION SPECIFICATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 14. THE CONTRACTOR SHALL VERIFY, COORDINATE, AND PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORTS FOR ALL ITEMS REQUIRING THE SAME. 15. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES, REGULATIONS, LAWS AND ORDINANCES AS WELL AS STATE DEPARTMENT OF INDUSTRIAL REGULATIONS AND DIVISION OF INDUSTRIAL SAFETY (OSHA) REQUIREMENTS. 16. THE CONTRACTOR SHALL PROTECT THE PROPERTY OWNERS, AND PACIFIC BELL WIRELESS PROPERTY FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING FINISHES, CONSTRUCTION, STRUCTURE, LANDSCAPING, CURBS, STAIRS, OR EQUIPMENT, ETC. SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF PACIFIC BELL WIRELESS, AND THE PROPERTY OWNER, OR THE OWNER'S REPRESENTATIVE, AT THE EXPENSE OF THE CONTRACTOR. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL REPLACE OR REMEDY, ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK BY PACIFIC BELL WIRELESS UNDER THIS CONTRACT. 18. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, OR CONTACT AN OUTSIDE AGENCY TO LOCATE ALL EXISTING UTILITIES. WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE PROJECT SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED AND ACCEPTED BY PACIFIC BELL WIRELESS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIITARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO PACIFIC BELL WIRELESS IS STRICTLY PROHIBITED. .. .. FLA Nill NG <,.II_LI{"' r· ](:·:}Iii .'11\CIIIH(_T 1;(,Q<I--J ::u.~rsEZ f--1,C-lr~CT ======== == ======== PREPARED FOR PACIFIC ■ BELL® Wireless 4420 ROSEWOOD DRIVE BUILDING 2, FOURTH FLOOR PLEASANTON, CALIFORNIA 94588 ======== :: ======== APPROVALS OPERATIONS DATE R.F. DATE ZONING DATE CONSTRUCTION DATE SITE ACQUISITION DATE ========= .. .. PROJECT NAME WEST BLUFF PLAZA PROJECT NUMBER SD-367-02 6994-B EL CAMINO REAL CARLSBAD, CA 92009 3/16/00 3/17/00 4/13/00 6/29/00 7/6/00 9/22/00 SAN DIEGO .. .. DRAWING DATES PRELIM ZD REVIEW ZONING SUBMITTAL PRELIM CD REVIEW PRELIM CD REVIEW 2 CD SUBMITTAL PERMIT SET .. ========= .. SHEET TITLE SITE PLAN GENERAL SPECIFICATIONS C <.A p c:,c, .. u, ======== == ======== PROJECTS\ PBW\ 9 9 09 6cd\ 9 9 09 6cAO. d w9 .. ========= .. A-0