HomeMy WebLinkAboutCDP 2021-0028; FLAMMER ADU; Administrative Determination2943 JEFFERSON ST. CARLSBAD, CA 92008 INITIAL BUILDING PERMIT SUBMITTAL SET SYMBOLS LEGEND REFER TO ARCHITECTURAL FLOR PLAN SHEETS AND CONSUL TANT DRAWINGS FOR ADDITIONAL SYMBOLS AND REFERENCE DESIGNATIONS DIMENSION REFERENCE .....,,_ __ □,_M _____ FACE OF OBJECT DIM CENTER LINE OF .,_ _____ -., OBJECT DETAIL REFERENCE -----DETAIL NUMBER 1 SI~ REFERENCE A120 LABEL WHERE OCCURES SHEET NUMBER SECTION REFERENCE ~l,_<,=--~-=-===-SECTION NUMBER Sl/,ir REFERENCE _1_ A12_0,07_..___ LABEL WHERE OCCURES SHEET NUMBER TAGS AND MARKERS PLAN REF. GRID AND/OR INTERIOR FIN.TYPE REVISION MARKER PLAN KEY NOTES Room name~ ROOM LABEL 150 SF..,._____ -........_ ROOM NAME -----ROOM NUMBER 0 WALL TYPE MARKER DOOR ID DOOR DESIGNATION ROOM NUMBER CENTER LINE MATERIALS REFERENCE f-1l1j [_:,,:\~J~Q EARTH GRAVEL/ROCK CONCRETE ~ ~ CONCRETE BLOCK (CMU) !'>,:•:.•:·:;-'.! SAND, GROUT, OR PLASTER fOJ STEEL PLYWOOD WOOD, CONTINUOUS MEMBER WOOD, BLOCKING WOOD, FINISH GRADE CABINET TYPES (PC) -PREFINISHED CABINETS (PM) -PREFINISHED MOBILE CABINETS (PR) -PREFINISHED MOVEABLE CABINETS (PU) -PREFINISHED UTILITY CABINETS (PS) -SCIENCE CABINETS NOTE: REFER TO SPECIFICATIONS FOR SPECIFIC CABINET TYPE REQUIREMENTS. PROJECT TEAM OWNER KIM FLAMMER 2943 JEFFERSON ST CARLSBAD, CA 92008 ARCHITECT DEVELOPMENT INTERGRATION GURUS INC. CONTACT: STEPHEN SUN LICENSE: C-38556 55 E 3RD AVE. SAN MA TEO, CA 94401 STEPHEN@DIGROUP.DESIGN 213.448.6489 TITLE 24 CONSUL TANT GETTITLE24 CONTACT: VIRANCHI VIRANCHl@GETTITLE24.COM CELL: 714.888.4736 DEFERRED ITEMS 1. PHOTOVOLTAIC SYSTEM 2. TRUSS SYSTEM CONTRACTOR SNAP ADU CONTACT: MIKE MOORE LICENSE: B-984791 YUCCA ROAD OCEANSIDE, CA 92054 WHITNEY@SNAPADU.COM 201.987.6024 STRUCTURAL ENGINEER TBD THE DEFERRED SUBMITTALS SHALL BE REVIEWED AND APPROVED BY THE ARCHITECT AND/OR ENGINEER OF RECORD PRIOR TO SUBMITTING TO THE CITY FOR REVIEW AND APPROVAL. THE DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED AND APPROVED BY THE CITY PRIOR TO FABRICATIONS AND INSTALLATIONS OF THESE ITEMS ----------------------------------~- PROJECT DATA ADDRESS: LEGAL DESCRIPTION APN: ZONING: YEAR BUILT: LOT SIZE: OCCUPANCY: CONSTRUCTION TYPE: SPRINKERED: COASTAL ZONE: EXISTING USE: EXISTING BUILDING AREA: EXISTING LOT COVERAGE: PROPOSED USE: DEMOLISHED AREA: PROPOSED ADDITION: NEW TOTAL BUILDING AREA: NEW LOT COVERAGE: STRUCTURE HEIGHT: NUMBER OF STORIES: FLOOR AREA RATIO: PARKING REQUIREMENTS REQUIRED CAR PARKING SPACES: PROVIDED CAR PARKING SPACES: ADU DEVELOPMENT GUIDELINES MAX ADU SIZE: MAX ADU HEIGHT: ADU FRONT SETBACK: ADU REAR SETBACK ADU SIDE SETBACK: ADU STREET SIDE SETBACK: 2943 JEFFERSON ST. CARLSBAD, CA 92008 TR775 BLK 49 LOTS 23 & 24 203-303-18-00 V-R, VILLAGE CENTER (VC) 1947 7,006 SF R-3 V-B NO YES SINGLE FAMILY DWELLING 1,288 SF (MAIN DWELLING)+ 400 SF (GARAGE) 1,688 / 7,006 = 024 SINGLE FAMILY DWELLING W/ DETACHED ADU 400 SF 749 SF 2,042 SF 2,042/ 7,006= 0.288 14' -1" (ADU) 1 0.288 1 1 1,200 SF 15' 5' 4' 4' 4' APPLICABLE CODES AND REGULATIONS 2 3 4 5 6 7 8 2019 BUILDING STANDARDS ADMINISTRATION CODE (PART 1, TITLE 24, CCR) 2019 CALIFORNIA RESIDENTIAL CODE (PART2.5, TITLE 24, CCR) (2018 INTERNATIONAL BUILDING CODE WITH 2019 CALIFORNIA AMENDMENTS) 2019 CALIFORNIA ELECTRICAL CODE (PART 3, TITLE 24, CCR) (2011 NATIONAL ELECTRICAL CODE WITH 2019 CALIFORNIA AMENDMENTS) 2019 CALIFORNIA MECHANICAL CODE (PART 4, TITLE 24, CCR) (2012 UNIFORM MECHANICAL CODE WITH 2019 CALIFORNIA AMENDMENTS) 2019 CALIFORNIA PLUMBING CODE (PART 5, TITLE 24, CCR) (2016 UNIFORM PLUMBING CODE WITH 2019 CALIFORNIA AMENDMENTS) 2019 CALIFORNIA ENERGY CODE (PART 6, TITLE 24, CCR) 2019 CALIFORNIA FIRE CODE (PART 9, TITLE 24, CCR) (2016 INTERNATIONAL FIRE CODE WITH 2019 CALIFORNIA AMENDMENTS) 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (PART 11, TITLE 24, CCR) 9 2019 CALIFORNIA REFERENCED STANDARDS CODE (PART 12, TITLE 24, CCR) 10 2016 ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PART 36) CITY OF CARLSBAD Administrative Permit CaseNo.Cv?20Zl -o"-2 ~ Exibit No.A".. '°N" .... ,He ... s · r w I Zj SCOPE OF WORK ADDITION OF NEW DETACHED 1 STORY ACCESSORY DWELLING UNIT (749 SF) TO AN EXISTING SINGLE FAMILY PROPERTY VICINITY MAP DRAWING INDEX SHEET NUMBER SHEET NAME OO_GENERAL NOTES G-001 !TITLE SHEET T24-1 iTITLE 24 ENERGY COMPLAINCE REPORT ------------MM-1 TITLE 24 ENERGY MANDATORY MEASURE ----- G-002 'GENERAL NOTES G-003 CALGREEN NOTES f----------~--G-004 :BMP 01-ARCHITECTURAL A-001 EXISTING SITE PLAN A-002 i PROPOSED SITE PLAN A-101 PROPOSED FLOOR PLAN A-201 EXTERIOR ELEVATIONS t---------=~ A-301 ,SECTIONS AND DETAILS --- A-502 SCHEDULES AND CALLOUTS f----------~-- YUCCA ROAD OCEANSIDE. CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co C) C) z N a, 0 <( u --I--0 Cll -.n C en -.:::: Cll C u <( ...... (f) C ::J 0 e Q) C :::::: Q) <( -, (") ""'" 0) N PROJECT STATUS NO. DESCRIPTION DATE 03 -ELECTRICAL ------------~ -----· --~ E1 .01 : ELECTRICAL FLOOR PLAN --~ _________ _,I-------- 1-----------l TOTAL SHEETS: 13 f------------------------------------------i DATE 2/1/2021 5:05:10 PM AGENCY# DIG JOB# SA 20182 TITLE SHEET G-001 -!,) CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Galcufation Description: Title 24 Analysis GENERAL INFORMATION 01 Project Name 2943 Jefferson St ADU 02 Run Title Title 24 Analysis 03 Project Location 2943 Jefferson St 04 City Carlsbad 06 Zip code 92008 08 ClimateZone 7 10 Building Type Single family 12 Project scope Newconstruction 14 Addition Cond. Floor Area {ft2) 0 16 Existing Cond. Floor Area (ft:2) n/a 18 Total Cond. Floor Area {ft2} 754 20 ADU Bedroom Count n/a 22 Is Natural Gas Available? Yes COMPLIANCE RESULTS 01 Building Compties with Computer Peliormance Calculation Date/Time: 202lcQ2~01T10:55:17~08:00 Input File Name: 1435_2943 Jefferson St._Energy Analysis_V8.ribd19x 05 Standards Version 2019 07 Software Version EnergyPro 8.2 09 Front Orientation (deg/ Cardinal) 90 11 Number of Dwelling Units 1 13 Number of Bedrooms 2 Number of Stories 1 Fenestration Average U-factor 0.3 Glaiing Percentage(%} 17.77% ADU Conditioned Floor Area n/a CFlR-PRF-OlE (Page 1 of 9} 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under ~he supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 421-P010014482A-000-000-0000000-0000 . Registration Date/Time: 02.101/2021 11 :5J _ HERS Provider: CHEERS NOTICE: This document has been generated by ConSo/ Home Energy Efficie1:ry Ratin9 System Servu::es, Jnr. (CHEERS) using inform«tion up/caded by t/1ir<1 P.,rt/cs r.ot affi/,ared with or related to CH£ERS_ Therefore, CHEERS is not responsible for, and amnrx guarantee, the accuracy or r;;ompleteness of the mformabon ,;ontamed m this document. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Calculation Description: Title 24 Analysis OPAQUE SURFACES 01 02 Name Zone Front Wal! E Living Area Rear Wall W Living Area RrghtWall N Living Area Left wans UvITlg Area Attic Roof Living Area ATTIC 01 02 Name Construction 04 Construction Azimuth R-19 Wall+ ws_ 90 R-19 Wall+ ws_ 270 R-19Wall+WS_ 0 R-19Wal!+WS_ 180 R-30 Roof Attic n/a ,, 03 .· 04 Type Calculation Date/Time: 2021-02-0lTl0:55:17-08:00 Input File Name: 1435_2943 Jefferson St._Energy Analysis_V8.ribd19x 05 Orientation Front Back Right Left ,;, 05 06 ~15.4 ).15.4 224 224 754 06 Roof Emittance 07 Window and Door Area (ft2) 62 0 40 32 o/a 07 Radiant Barrier CFlR-PRF-OlE {Page 4 of 9) 08 Tilt {deg) 90 90 90 90 n/a 08 Cool Roof Attic Living Area Attic RoofLivlng Area Ventilated .4 0.1 0.85 Yes No FENESTRATION/ GLAZING 01 02 03 04 05 Name Type Surface Orientation Azimuth Window 1-5040_ Window Front Wall E Front 90 Door 3-5070_ Window Front Wall E Front 90 Window 1-5040_ 2 Window Right Wall N Right 0 Door 4-3068_ Window Right Wall N Right 0 Window 1-5040 3 Window left Wall S Left 180 Window 2-3040 _ Window left Wal! S Left 180 Width {ft) H'eight (ft) 08 1 1 1 1 1 1 09 Area {ft') 20 42 20 20 20 12 10 LI-factor 0.3 0.3 0.3 0.3 0.3 0.3 11 LI-factor Source NFRC NFRC NFRC NFRC NFRC NFRC 12 SHGC 13 SHGC Sourc e 0.23 NFRC 0.23 NFRC 0.23 NFRC 0.23 NFRC 0.23 NFRC 0.23 NFRC 14 Exterior Shading Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Registration Number: 421-P010014482A-000-000-DOOOOOO-OOOO Registration Date/Time: 02/01/2021 11 :53 HERS Provider: CHEERS NOTICE, This document h;,s been gene,ateo by Con Sol Home'. Energy Efficiency Ratillf! System Services, rnc. (CHEERS) usmg intormat,on uploaded bV tli/rd parties Mt affiliated wirh or related to CHEERS. Therefore, CHEERS fs not rr,sponsible For, and cannot guarantee, the acr:uracv or completeness of the fnformabon contained in this doc1.Jment. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU cafculation Description: Title 24 Analysis HVAC -HEATING UNIT TYPES 01 Name Heating Component 1 HVAC -COOLING UNIT TYPES 01 02 Name System Type Cooling Component 1 No Cooling HVAC-DISTRIBUTION SYSTEMS 01 Name Air Distribution System 1 02 Type Unconditioned attic HVAC DISTRIBUTION -HERS VERIFICATION 01 Name Air Distribution System 1-hers-dist 02 Duct Leakage Verification Yes 02 System Type Central gas furnace 03 04 calculation Date/Time: 2021-02-01T10:55:17-08:00 CF1R-PRF-01E {Page 7 of 9) Input File Name: 1435_2943 Jefferson St._Energy Analysis_ V8.ribd19x 03 04 Number of Units Heating Efficiency 1 AFUE-80 05 06 07 08 Number of Units Efficiency EER/CEER Efficiency SEER Zonally Controlled Mu lit-speed Compressor HERS Verification 1 03 Design Type Non-Verified 03 Duct Leakage Target{%) 5.0 ,1, 04 Duct Ins. R-value Supply Return R-8 04 Verified Duct Location Not Required R-8 ",· ,, n/a Not Zonal 07 08 09 Duct Location Surface Area Supply Return Supply Return Attic OS Verified Duct Design Not Required Attic n/a 06 Buried Ducts Not Required n/a 07 Deeply Buried D,cts Credit not taken Single Speed n/a 10 11 12 Bypass D,ct Duct Leakage HERS Verification No Bypass Duct 08 Sealed and Tested Low-leakage Air Handler Not Required Ale Distribution System 1-hers-dlst 09 Low Leakage Ducts Entirely in Conditioned Space No Registration Number: 421-P0100144B2A-000-000--0000000-0000 Registration Date/Time: 02/01/2021 11 :53 HERS Provider: CHEERS NOTICE: T.~;5 document has been gene,-ated by Co.~Sol Home E~erg~ Eff/dency Ratin_g System Services, Inc. (CHEERS) usm~ information ~•ploaaed by third p;,rt,i,s not affiliated wir:h or related to CHEERS. Therefore, CHEERS is nor respunsib/e for, ana cannot guarontee, tile. acce1raq' or completeness of the mform;mon crmramed m this do,;:ument. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Calculation Description: Title 24 Analysis ENERGY DESIGN RATING Standard Design Proposed Design Calculation Date/Time: 2021-02-0lTl0:55:17-08:00 Input File Name: 1435_2943 Jefferson St._Energy Analysls_V8.ribd19x Energy Design Ratings Compliance Margins CF1R-PRF-01E {Page 2 of 9) Effidency1 (EDR) Total2 (EDR) Efficiency1 {EDR) TotaP (EDR) 60.5 30 60.5 29.9 0 0.1 RESULT: 3: COMPLIES 1: Efficiency EDR includes improvements to the building envelope and m<'Jre efficient equipment 2: Total EDR includes efficiency and demand response measures such as photo11oltaic (PV} 'sy51:'emS and batteries 3: Building complies when efficiency and total compliance margins are gr;:ater than or equal to zero, • Standard Design PV Capacity: 1.75 kWdc • PV System resized to 1.75 kWdc (a factor of 1.752) to achieve 'Standard Design PV' P_V scaling Energy Use {kTDV/ft2-yr) Space Heating Space Cooling IAQ Ventilation Water Heating Self Utilization/Fiexibility Credit Compliance Energy Total REQUIRED PV SYSTEMS-SIMPLIFIED 01 DC System Size {kWdc) 1.75 02 Exception NA I 03 Module Type Standard Standard Design 0.43 10.07 3.58 26.69 o(, 40.77 04 Array Type Fixed ENERGY USE SlJMMARY I 05 Power Electronics none Proposed Design 1.47 9.07 3.58 26.69 0 40.81 06 true 07 Azimuth (deg) 150-270 I 08 TIit Input n/a Compliance Margin -1.04 1 0 D 0 -0.04 09 Array Angle {deg) cf, 10 Tilt: {x in 12) <=:7:12 Percent Improvement 11 -241.9 9.9 0 0 n/a -0.1 12 Inverter Eff. (%) Annual Solar Access (%) 96 100 Registration Number: 421-P010014482A-000-000-0000000-0000 Registration Date/Time: 02/01/2021 'il:53 HERS Provider: CHEERS NOTJCE: This document has boon generated by Con Sc/ Home Energy Efficiemcy P.atmg Svst""! Services, Inc. (CHEERS) usmg infarmetion up/oadea by third pa;-t.ies not «ffiliated with o0 related to CHEERS. ThereFore, CHEER.S ,snot responsible for, and cannot guarantee, th<' a"';uraey or completeness of the inform~t:Jor, contamed 1,1 t/115 doc1.Jment CA Building Energy Efficiency Standards -2019 Residential Compliance Report Versfon: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Calculation Description: Title 24 Analysis SLAB FLOORS 01 02 Name Zone Slab-on-Grade Uving Area OPAQUE SURFACE CONSTRUCTIONS 01 Construction Name R-19 Wall+ ws_ Attic RoofUving Area R-30 Roof Attic_ 02 Surface Type Exterior Walls Attic Roofs Ceilings (below attic) BUILDING ENVELOPE-HERS VERIFICATION 01 Quality Insulation Installation (Q!I) Not Required Calculation Date/Time: 2021-02-0lTl0:55:17-08:00 CF1R-PRF-01E (Page 5 of 9) Input File Name: 1435_2943 Jefferson St._Energy Analysis_V8.ribd19x 03 754 03 Construction Type Wood Framed Wall Wood Framed , Ceiling Wood Framed Ceiling 02 04 Perimeter {ft} 110 04 ., Fraff'ling-- .... 2x6@ 16_iri. Ci. _C. 2x4@ 24 in. 0. C. High R-value spray Foam Insulation Not Required OS Edge rnsul. R-va!ue and Depth none 05 06 Edge lnsul. R-value and Depth 0 06 Interior/ Exterior 07 08 Carpeted Fraction Heated 80% No 07 08 Total Cavity R-value Continuous LI-factor Assembly Layers R-value R-19 None/ None 0.07 ,.o None/ None 0.644 R-30 None/ None 0.032 03 Building Envelope Air Leakage Not Required inside Finish: Gypsum Board Cavity/ Frame: R-19 in 5-1/2 in. [R-18) / 2,6 Exterior ~inish: Wood Si ding/ sheathing/decking Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/ decking Cavity/ Frame: no 1nsul. / 2x4 Over Ceiling Joists: R-20.9 insul. Cavity/ Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 04 CFMSO ,;, Registration Number: 421-P010014482A-OOO-OOO-OOOOOOO-OOOO Registration Date/Time: 02101/2021 11:53 HERS Provider: CHEERS ~~J;o~!ib!::'.{/0~~;ti;~:;?g~~';.~,fr':,;~~tt,;'~iiu ... ~~;5a0: :o~pie~~i:?tr fr!:i/ir;Z,':;,~f;~,f{~~Y;';r;~~"f~ldi:/2ic:S~~~f.RS} using information uploaded by thira parrif!S not afflhated ~it/1 or re/;,ted ro CHEERS 711~efore, Ci--/f:CRS /$ noL CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021--02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Calculation Description: Title 24 Analysis HVAC-FAN SYSTEMS 01 Name HVAC Fan 1 !AQ (INDOOR AIR QUALITY} FANS 01 02 Dwelling Unit IAQCFM SFam IAQVentRpt 45 02 Type HVAC Fan 03 IAQ Watts/CFM Calculation Date/Time: 2021-02-01T10:55:17-08:00 CF1R-PRF-01E {Page 8 of 9) Input File Name: 1435_2943 Jefferson St._Energv Analysis_ V8.ribd19x 04 IAQFanType Default 03 04 Fan Power {Watts/CFM) Name 0.45 n/a 05 06 !AQ Recovery Effectiveness - IAQ Recovery Effectiveness{%) SREIAQ Recovery Effectiveness -SRE 0 n/a Registration Number: 421-P010014482A-000-000-0000000-0000 Registration Date/Time: 02/0112021 11:53 HERS Provider: CHEERS NOTICE; This doc~,ment has been generaterf by Consol Home Energy Efnciency Rating Sy5tem Ser,(ices, !nc. {CHEERS) using mform,;t1on up/o.,dc,d by third parties not affilic:ted with or related to CHEERS. Therefore, CHEERS 1s not respons,ble for, f!r.d rannot 91.Jarantee, the accuracy o, completeness of the informahOn r:or.ta;M:d m this document, CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:3S Schema Version: rev 20200901 CERTIFICATE_ \JF COMPLIANCE Calculation Date/Time: 2021-02-01T10:55:17-08:00 CF1R-PRF~01E (Page 3 of 9) Project Nam~: 2943 Jefferson St ADU Calculation gescription: Title 24 Analysis Input File Name: 1435_2943 Jefferson St._Energy Analysis_ V8.ribd!9x >-R-EQ_u_,-:·'_"~S-P-,C:c~IA_L_'_'_AT_u_._" ________ ~ ___ _c:... _____ :::_:------------------==------------·~·· 1 The following '.Jre features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts With hlgh level of insulation HERS FEATURi;_ SUMMARY The following 1s a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computei-analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: • Indoor i1ir quality ven"':.ilation • Kitchen range hood Cooling System Verifications: • -None-- Heating Syste1n Verifications: • --None- HVAC Distribution System Verifo:atlons: • Duct leokage testing Domestic Hot Water System Verifications: • -None-- BUILDING -F(A.TURES INFORMATION 01 02 Projt'ct Name Conditioned Floor Area {tt2) 2943 Jeffa:rsor, St ADU 754 ZONE INFORMATION 01 02 03 Number of Dwelling Units 1 03 04 05 Number of Bedrooms Number of Zones 2 1 04 05 06 Number of Ventilation Cooling Systems 0 06 07 Number of Water Heating Systems 1 07 Zone Name 2one Type HVACSystem Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Living Area Conditioned HVAC Systeml 7S4 8 DHW Sys 1 N/A Registration Number: 421-P010014482A-000-000-0000000·0000 Registration Date/Time: 02/011202111:53 HERS Provider: CHEERS NOTICE: rhis document has been generated bf Con So/ Hrnne Energy E.'flclencv Ratin_g Sy_e:tem Services, ;n,:. (CHEERS} usmg mform;;t,on 1.Jp/oeded by ::hrrd pE1rt1es rmt affiiiatCTi with or re/atr!d to CHEERS_ Thert'fore, CHEERS 1s not responsible fo,, t,lld c,,nr,ot g,ia,rantee, the acc1,ra,y o, ,omplewness of the mformat1on con tamed in th's docum2nt. CA Building Energy Efficiency Stanc!ards -2019 Residential Com;:iliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU calculation Description: Title 24 Analysis WATER HEATING SYSTEMS 01 02 03 Calculation Date/Time: 2021-02-01T10:55:17-08:00 Input File Name: 1435_2943 Jefferson St._Energy Analysis_ V8.ribd19x 04 05 06 CF1R-PRF~01E {Page 6 of 9) 07 Nam,a System Type Distribution Type Water Heater Name{#) Solar Heating System Compact Distribution HERS Verification DHWSvs 1 WATER HEATERS 01 Name DHW Heak,1 Domestic Hot Water (D,'7W) Standard Distribution System 02 Heating E!ement Type Gas 03 Tank Type Consumer Instantaneous 04 #of Units 1 05 Tank Vol. (gal) 0 WATER HEATING -HERS VERIFICATION 01 02 03 06 Energy Factor or Efficiericy 0.81-UEF 04 DHW Heater 1 (1) 07 tnput Rating or",Pilot 200000- Btu/Hr' I 08 Tank Insulation R•va!ue (Int/Ext) 0 05 n/a 09 10 Standby Loss 1st Hr. Rating or Recovery Eff or Flow Rate n/, n/a 06 Name Pipe Insulation Parallel Piping . Compact Distribution Compact Distribution Type . Recirculation Control DHW Sys l -1/1 Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 Name HVAC Syster.il 02 System Type Heating and cooling system other 03 04 Heating Unit Cooling Unit Name Name Heating Component 1 Cooling Component 1 Fan Name HVAC Fan 1 None 06 Distribution Name Air Distribution System 1 Not Required 07 Required Thermostat Type Setback 08 Status New None c/a 11 12 NEEA Heat Pump Brand or Model Tank Location or Ambient Condition n/a 07 Central DHW Distribution Not Required 09 Verified Ex:isting Condition NA n/a 08 Shower Drain Water Heat Recovery Not Required 10 Heating Equipment Count 1 11 Cooling Equipment Count 1 Registration Number: 421-P010014482A-OOO-OOO-OOGOOOO-ODOO Registration Date/Time: 02/01/2021 11.53 HERS Provider: CHEERS NOTICE: Th,s document h«s been gencratc:<1 by ConSo! Home Energy Efficfoncy P,c,,;in,; Sv5tem Sen·ic~ .. Inc. (CHEERS) using i11format1on uploaded by C~ird pc,rtie5 not affiliated w/U1 or related to CHEERS. Therefore, CHEERS is not responsfble for, am:1 cannot ge1arant;;e, the accuracy or comp/etene5S of the mtorma/ion contc>m~d ,rr th,s doCl.!ment. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 2020090::_ CERTIFICATE OF COMPLIANCE Project Name: 2943 Jefferson St ADU Calculation Description: Title 24 Analysis DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and rnmplete. Documentiltion Author Name: Viranchi Shah Company: www.gettitle24.com Address: 14730 Beach Blvd., #133 Oty/State/Zip· La Mirada, CA 90638 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State uf California· Calculation Date/Time: 2021-02-0lTl0:55:17-08:00 Input File Name: 1435_2943 Jefferson St._Energy Analysis_V8.ribd19x Documentiltion Author Signature: vw~ 5'/uih, Signature Date: 02/01/2021 CEA/ HERS Certificiltion Identification (lfilpplicable): Phone: 714-888-4736 1. ! am eligible under Divlsion 3 of the B1.:siness ;,nd Professiorcs Code to acceot responsibility f6r th0,building design idimtified on this Certific;ite of Compliance. CFlR-PRF-OlE (Page 9 of 9) 2. ! certify that t~e energy features and performance specifications identified on this Certificate of Compliarice conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Comp!iance,are consistent with the information provided on other appilcabie compiiance docurn':!nts, worksheets, calculations, p:ans and specifications submitted to the enforcement ageni:y for approval with this building permit application. Responsible Designer Name· Stephen Sun Company: Deveiopment Integration Gurus Address: 645 California Street City/State/Zip· Mountain View, CA 94041 , Responsible Designer Signature: Steph0n, S U¥v Date Signed: 02/01/202,1 Phone· (213) 448-6489 Registration Number: 42i-P010014482A-OOO-OOO-OOOOOOO-OOOO Registration Date/Time: 02/01/202111:53 HERS Provider: CHEERS NOTICE: This drxumenr has been generated by Con Sol Home Ene.-gy Efficiency Fl.atinq System Ser•1ices, Inc. (CHEERS) r,s,ng in Formation uploc>ded by third {)<lrties not affiliated with or related to CHEERS. Therefore, CHEERS ts not responsible for, and a,nnot guarc1ntee, the arwracv or comp!ar:eness MtM /Mormation con tamed m this document. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.300 Report Generated: 2021-02-01 10:56:35 Schema Version: rev 20200901 >-co 0 w 0:::: <( Q_ w 0:::: Q_ ,;::I" N I- l-o:::: 0 Q_ w 0:::: w 0 z <( ...J Q_ 2: 0 0 >-(9 0:::: ..... w ZLL wo w ~ 0 s::f"..- N1- WW ...J w I-I I-C/) ::> 0 <( -C/) C: 0 ~ ~ Q) -, (") ,;::I" O"l N co 0 ~o (/)N cm O<( ~() ~ - Q) ~ -, .0 <:') (/) "St--c a, "' NO (/) (/) w D:'. 0 0 <( <O <:') !'- "St- ' co co co w z 0 I a. T24-1 . RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type @ Single Family □ Addition Alone 2943 Jefferson St ADU □ Multi Family □ Existing+ Addition/Alterauon Project Address 2943 Jefferson St Carlsbad California Energy Climate Zone CA Climate Zone 07 ', Total Cond, Floor Area I ' 754 Ad~iition nta I # of ~nits INSULATION Construction Type Cavity Area (ff) Special Features Status Wall Wood Framed R 19 745 New Slab Unheated Slab-on•Grade -no insulation 754 Perim = 110' New >-----------------·---·----------------------------------------1 ---------I FENESTRATION Orientation Area(ff) I Totai Area: U-Fac 1341 Glazinn Percentane: 17.8% I New/Altered Averane U-Filctor: 0.30 SHGC Overhang Sidefins Exterior Shades Status Front (E) 20.0 0.300 0.23 none none NIA New Front (E) 42.0 0.300 0.23 none none NIA New Right(N) 20.0 0.300 0.23 none none NIA New Right (NJ 20.0 0.300 0.23 none none NIA New --...... ··-····"· ---------... , .... ------ Left. (S) 32.0 0.300 0.23 none none NIA New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Centre! Furnace 80%AFUE No Cooling 14.0 SEER Setbeck New >------------------------------·-·-·· -·· HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC System Ducted Ducted Attic 8.0 New 1----------------~---· WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Small Instantaneous Gas 0.81 Standard New EnemvPro 8.2 bv EnerovSoft User Number: 3835 ID: 001 Pane 12 of17 -- § 150.0(k)2G: § 150.0(k)2H: § 150.0(k)21, § 150.0(k)2J: § 1500(k)2K: § 150.0(k)3k § 150.0(k)38i § 150.0(k)3C: § 150.0(k)4: § 150.0(k)5: § 150.0(k)6A, § 150.0(k)6B: 2019 Low-Rise Residential Mandatory Measures Summary Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it: provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of§ 130.4; meets the EMCS reouirements of S 130.0/e); and meets all other requirements in G 150.0/k\2. Interior Switches and Controls. A multiscene programmable contro!!er may be used to comply with dimmer requirements in § 150.0(k) if it orovides ihe functionalitv of a dimmer accordino to t 110.9, and complies with al! other aoolicable reouirements in & i 50,0(k'l2. Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in ear:h of these spaces must be controlled by an occupant sensor or a vacancy sensor providing automatic-off functionality. If an occupant sensor is installed, it must be initially configured to manual-on operation using the manual control required under Section 150.0(k)2C. Interior Switches and Controls. Luminalres that are or contain light sources that meet Reference Joint Appendix JA8 requirements for dimmino, and that are not controlled bv occupancv or vacancv sensors. must have dimmino controls. Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling-installed lighting systems_ Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must meet the requirement in item§ 150.0(k)3Ai (ON and OFF switch) and the requirements in either S 150.0(k)3Aii (photocell and either a motion sensor or automatic time switch control) or S 150.0(k)3Aiii /astronomical time clock), or an EMCS. Residential Outdoor Lighting. Far low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances, balconies. and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either§ 150.0(k)3A or with the apolicable reauirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0, Residential Outdoor Lighting. For !ow-rise residentia! buildings with four or more dwelling units, any outdoor lighting for residential parking lots-· or carports with a total of eight or more vehicles per site and any outdoor fighting not regulated by§-150.0(k)3B or§ 150.0(k}3D must comply with the applicable requirements in Sections ': 10.9, 130.0, 130.2, 130.4, 140.7 and 141.0 Internally illuminated address signs. Internally illuminated address signs must comply with§ 140.8; or must consume no more than 5 watts of oower as determined accordinc to~ 130.0[c). Residential Garages for Eight or More Vehicles. Lighting for resfdentlal par'i<ing garages for eight or more vehicles must comply wijh the applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. ---·· ~-~-~~~; Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that buildinq must be comptvwith Table 150.0-A and be controlled bv an occupant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in that building must: i. Comply with the applicable requirements in Sections 110.9, 13G.O, 130.1. 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors trc1t reduce the lighting power in each space by at least 50 percent. The occupant sensors must Je capable of turning the tight fully on and off from all designed pa~hs of ingress and egress. Solar Ready Buildings: § 110.10(a)1: § 110.10(a)2: § 110.10(b)1: § 110.10(b)2, § 110.10(b)3A: § 110.10(b)3B: § 110.10(b)4: § 110.10(c): § 110.10(d), § 110.10(e)1: § 110.10(e)2: Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a ohotovoltaic svstem installed, must comntv with the renuirements of s 110:lO(b) throunh s 110.10(e\. Low-rise Multifamily Buildings. Low-rise multi-family buildings that do not have a photovoltaic system installed must comply with the requirements of§ 110.10(b) through § 110.10(d). Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation. and spacing requirements as specified in Title 24, Part 9 or other parts of Titie 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi-famiiy buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of anotller structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone requirement is applicable to the entire buiiding, including mixed occupancy.' Azimuth. All sections of the solar zone located on steep-sloped roofs must be oriented between 90 degrees and 300 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted eoui□ment.· Shading. A.ny obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projectlon of the nearest point of the solar zone, measured in the vertical plane.· Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof dead load and roof !ive load must be clearlv indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location reserved fur inverters and metering equipment and a pathway reserved for roubng of conduit from the solar zone to the point of interconnection with the electrical service; and for single family residences and central waler-heatina svstems. a oathwav reserved for routina [ lumbina from the solar zone to the water-heatino svstem. Documentation. A copy of the construction documents or a comparable document indicating the information from§ 110.1 O(b) through & 110.1 O(c\ must be provided to the occupant. Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Eiectrical Service Panel. Tne main electrical service panel must have a reserved space to allow for the installation of a double pole circuit breaker for a future solar electric instaliation. The reserved space must be permanently marked as "For Future Solar Electric". 2019 Low-Rise Residential Mandatory Measures Summary NOTE: Low➔rise residential buildings subject to the Energy Standards must comply with a!/ applicable mandatory measures. regarciless of the compliance approach used. Review the respective section for more information 'Exceptions may app/y_ (01120201 Building Envelope Measures: § 110.6(a)1: ji 110.6(a)5: § 110.6(b): § 110.7: § 110.B(a): § 110.8(g), § 110.BQ): § 110.BG): § 150.0(a) Air Leakage. Manufactured fenestration. exterior doors, and extertor pet doors must limit air leakage 10 0.3 CFM per square foot or less when tested ner NFRC-400, ASTivl E283 or AAMAJWDMAJCSA 101/l.S2/A440-2011.· Labeling. Fenestration products and exterior doors must have a labe! meeting the requirements of§ 10-111 (a}. Field fabricated exterior doors and fenestration products must use Li-factors and solar heat gain coefficient (SHGC} values from Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. Thev must be caulked and/or weather-strioped.' Air Leakage. All joints, penetrations, and ether openings in the building envelope that are potential S(Jurces of air leakage must be caulked, casketed, or weather striooed. Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods and Services (BHGS). Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of§ 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values o~the roofing material must meet tile requirements of S 110.8/i) and be labeled oer srn-113 when the installati@ of a cool roof is soecifled on the CF1 R. Radiant Barrier. When required. radiant barriers must have an emit"..ance of 0.05 or less and be certified to the Department of Consumer Affairs Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame celling; or the weighted average LI-factor must not exceed 0.043. Minimum R-19 or weighied average U-factor of 0.054 or less in a rafter roof alteration. Attic access dnors must have permanently attached insulation using adhesive or mechanlcal fasteners. The attic access must be gasketed to prevent air l1Jakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is seaied to limit infiltration and exfiltration as spocified in§ 110.7, including but not limited >-------~to~,o~l•~c=ing Insulation either above or below the roof deck oron top of a drywall_celling.' ______ ~·· ··--- § 150.0(b), § 150.0(c): § 150.0(d): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wa!I Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or have a Li-factor of0.071 or less. Opaque non-framed assemblies must have an overall assembly Li-factor not exceeding 0.102. Masonry walls must meet Tables 150.1-A or B.' Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-ractor. --·---.• -·-·-""·-·- § 1so.orn, Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rrile, for the insulation material alone without facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor. meet the requirements of§ 110.B(g). --·---· .. -----~-~~~-~~---~~~~~-~~-~--~-~---~--~~~~-~~~~-------1 Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawi space must be covered with a Class I or Class II vapor § 150.0(g)1 retarder. This reauirement also a~lies to controiled ventilation crawl space for buildi~g~c_q__n:ipJ1'l!:!a_w1th the exception to §_150.D(d).0. ~---a Vapor Retarder. In climate zones 14 and 16. a Class I or Class I! vapor retarder must be installed on the conditioned space side of all § 150.0(g)2, § 150.0(q): insulation in all exterior walls, vented attics, and unvented attics witii air-oermeab!e insulation. Fenestration Products. Fenestration, including sl{yiighls, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of a!I fenestration must not exceed 0.58.· Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 1 i0.5(e) Pilot Light Coniinuously burning pilot li-ghts are not allowed for indoor and outdoor fireplaces. § 150.0(e)1 §1500(e)2, § 150.0(e)3: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is eauloped with a readilv accesslble, ooerable, and tiohl-fittina damoer or combustion-air control device: Flue Damper. Masonry or factory-built :ireplaces must have a fiue damper with a readily accessible control.' Space Conditioning, Water Heating, and Plumbing System Measures: Certification. Heating. ventilation and air conditioning (HVAC) equipment, water heaters, showerileads. faucets, and all other regulated § 110.0-§ 110.3: aooliances must be certified bv the manufacture:-to the California Enerov Commission: § 110.2(a): §1102(b), § 110.2(c): § 110.3(c)4: § 110.3(c)6: § 110.5: § 15C.O(h)1: HVAC Efficiency. Equipment must meet the app!icabie efficiency requirements in Table 110.2-A through Table 110.2-K.T Controls for Heat Pumps wlth Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for comoression heatina is hiaher than the cut-off temoerature for suo□!emenlarv heatina: Thermostats. All heating or cooltng systems not controlled by a central energy management control system (EMCS) must have a setback thermostat." Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating reclrculation loops serving multiple dweliing units must meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculatiorl loop connection requirements of § 110.3(c)4. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must !",ave iso!abon valves with hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited ior natural gas: fan-type central iumaces; household cooking appliances (except appliances without an electrical s:.ippiy voltage connec'-Jon with pilot lights that consume less than 150 Btu per hour); and pool and spa healers. Building Cooling and Heating Loads. Heating and/or cooling loads ar,e calculated in accordance with the ASHR.A.E Handbook. Equipment Volume. Applications Volume. and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual: orlhe ACCA Manual J using design conditions specriied in§ 150.0(h)2. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name 2943 Jefferson St ADU System Name HVACSyslem ENGINEERING CHECKS Number of Svstems SYSTEM LOAD 0.te 211/2021 Floor Area 754 COlL COOUNG PEAK COlL HTG. PEAK CFM I Sensible Latent CFM Sensible Heating ~ts.;,e_m _____ ~-------l Output per System 40,000 Tota! Room Loads cl ___ 2s_o~i ___ s_.1_o_e+-------""--9+ __ 2_0_0+ ___ 7_.7_8S--l0 Return Vented Lighting I O Total Output (Btuh) 40,000 Output {Btuh/sqft) 53.1 Return Air Ducts r-;9-5 328 Cooling System Output per System 0 Return Fan ~---+-----o_ Ventilation I ~---+----0 0 0 0 0 0 Total o,.-ut IBtuh} D Supp I y Fan 0 0 Supply Air Ducts 195 ----- 328 Total Output (Btuh/sqft) 0.0 449 8.445 Total OutJ?.!:•.1J~_qftJTo_!!}_ ______ .. , .. ______ o.~ TOTAL SYSTEM LOAD 6,496 ·------·------~----~---~---~-------l Afr System CFM per System 0 HVAC EQUlPMENT SELECTlON Airflow (cfm) 0 Standard Fau Airflow (cfm/sqft) Q_OD Airflow (cfm/Ton} _ 0.0 ~--··-·-... ~-----------_,,. __ ,, __ -·---- Outside Air(%) 0.0% Total Adjusted System Output Outside Air (cfm/sqft) 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK HEATING SYSTEM PSYCHROMETRICS {Airstream Temperatures at Time of Heating Peak) 67°F i-J5°i= s -+---.-----+----+ fs!E,?1----------+-□l-- outsicte Air = :J --0ctm Heating Coil 67 Of ------'-----<----□ 1:.1 COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 33:67"F 75!62°F 55/54°F ---+--,,..,.___. ________ ~-------• l,i_ Outside Air _ ~ ~ 1 Dcfm Cooling Coil 75ie2"F f7 ---------+-------iJ 0 0 40,000 0 0 40,000 Aug 3 PM I Jani AM ROOM :~!~ 68 °F I 55l54°F § 150.0(h)3A: § 150.0(h)3B: § 150.0(j)1: § 150.0G)2A: § 150.00)3: § 150.0(n)1: § 150.0(n)2, § 150.0(n)3· 2019 Low-Rise Residential Mandatory Measures Summary Clearances. Air conditioner and heai pump ourdoor condensing units must have a s!earance of at least five feet from the outlet of any dryer Liquid Line Drier. Air condiEioners and heat pump systems must be equipped with 1iquid line filter driers if required, as specified by the manufacturer's instructions. Stora_ge Tank Insulation. UnTI:ed hot waier tanks, such as s_t_orage tanks and backup storage tanks for solar water-heating systems, must have a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water-heating System Piping, and Space Conditioning Sy;1;tem Line Insulation. All domestic hot water piping must be insulated as specified in Secticn 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum insulation wali _thickness of one inch or a minimum insulation R-value of 7. 7: the first five feet of cold water pipes fmm the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch: all hot water piping with a nominal diameter iess than 3/4 inch that is: associated with a domestic hot water reclrculation system, frorn the heating source to storage tank or between tanks. buried below grade, and from the heating source to kttchen fixtures.~ Insulation Protection. Piping insulation must be protected from damage, including that due lo sunlight, moisture, equipment maintenance. and wind as required by Section 120.3(:J). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes). Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be proiected by, a Class ! or Class I! va;:ior reiarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane waler heaters to serve individual dwelling units must ir.clude ali of the following: A dedicated 125 volt. 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 1 O AWG copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the word "spare" and be electrically isolated. Have a reserved single pole circuit breaker space in the elecirical panel adjacent to the circull breaker for the branch circuit and labeled with the words 'Future 240V Use'; a Category Ill or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base of the water heater, and allows natural draining without pump assistance: and a gas supply line with a capacity of at least 200,000 Btu per hour. Recirculating Loops. Recircu!ating ioops serving multiple dwelling units must meet the requirements of§ 140-3(c)5_ Solar Water-heating Systems. Solar water-heating systems and coliectors m:.ist btil certified and rated by the Solar Rating and Certification Corporation (SRCC). the lntem1ational Association of Plumbing and Mechanical Officials, Research and Testing (lAPMO R&T). or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: § 150.0im)1: § 150.0(m)2: § 150.0(m)3: § 150.0(m)?, § 150.0(m)B: § 150.0(m)9: § 150.0(m)10, § 150.0(m)11 § 150.0(m)12: § 150.0(m)13: Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). !fa contractor instalis the insulation. the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air-distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0. 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated to a minimum installed level ofR-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core offlexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duel-closure system that meets the applicable requirements of UL 18"!, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. !f mastic or tape is used to seal openings greater than¼ inch, the combination of mastic and either mesh or tape must be used. Building cavities. support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet me'.al, dee! board or flexible duct must not be used to convev conditioned air. Building cavities and support platforms may contain ducts_ Ducts installed in cavities and support platforms must not be com Pressed lo cause reductions in the cross-sectionai area: Factory-Fabricated Duct Systems. Factory-fabricated duct sys1ems must comply with applicable requirements for duct construction, connections. and closures; joints and seams of duct systems and their components mus! not be sealed wlth cloth back rubber adhesive duct tapes unless such tape is used in Gombination with mastic and draw bands Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requiremenis for: pressure-sensitive iapes, mastics, sealants, and other requirements specified for duct construction. Backdraft Damper. Fan systems that exchange air between the conditioned ;:,-psce and outdoors must have backdraft or automaiic dampers. Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readi!)'' accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents_ Protection of Insulation. Insulation must be protected from damage, sunlight moisture, equipment maintenance. and wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water r(J!ardant and provides shielding from solar radiation. Porous Inner Core Flex Duct. Pero us inner core flex ducts must have a non-porow; layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use fr_irced air duct systems to supply conditioned air to an occupiable space, the ducts must be sealed and duel leakage tested, as confirmed through field verification and diagnostic testing, in accordance1Alth § 150.0{m)11 and Reference Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements ir: §150.0(m)12. Filters must be accessible for regular service.* Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole for the placement of a static pressure probe. or a permanently installed static pressure probe in the supply plenum. Airflow must be;;: 350 CFM per ton of nominal cooling capacity. and an air-handling unii fan efficacy :a;; 0.45 watts per CFM for gas furnace air handlers and :a;; 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow;;: 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy :a;; 0.62 watts par CFM. Field verification testing is required ir. accordance with Reference Residential Appendix RA3.3.* 2019 Low-Rise Residential Mandatory Measures Summary Requirements for Ventilation and Indoor Air Quality: § 150.0(o)l Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requiremenis of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. -------~~~~~~-~------------~~~-~-~-~~~~---------------< Single FamHy Detached Dwelling Units. Single family detached dwelling units, and attacl:ed dwelling units not sharing ceilings or floors with § 150.0(o)IC: § 150.0(o)1E: § 150.0(o)1F: § 150.0(o)1G, other dwelling units, occupiabre spaces, publlc garages. or commercial spaces must have mechanical venti[ation airflow provided at rates determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in§ 150.0(o)1C. Multifamily Attached Dwelling Units. Muitifamily attached dwelling units must have mechanical ventilation airrlow provided at rates in accordance with Equation 150.0-B and must be either a ba!anced system or continuous supply or continuous exhaust system. If a balanced system is not used, all units in the building must use the same system type and the dwelling-uni! envelope leakage must be :::i 0.3 CFM at 50 Pa (0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Central Ventilation Systems. Central ventilalion systems that serve multiple dwelling units must be balanced to provlde venUiation airflow for each dwelling unit served at a rate equal to or greater than the rate specm"ed by Equation 150.0-B. Ali unit airflows mus! be within 20 oercent of the unit with the lowest airflow raie as it relates to the individual unit's minimum required airflow rate needed for comoliance. Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2. Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential § 150.D(o)2: Appendix RA3.7. A kitchen range hood must be verified In accordance with Reference Residential Appendix RA3.7.4.3 to confinn it is rated bv HV! to comply with the airflow rates and sound recuirements as specified in Section 5 and 7 2 of ASH RAE 62.2. Pool and Spa Systems and Equipment Measures: § 110.4(a): § 110.4(b)1: § 110.4(b)2, § 110.4(b)3: § 110.5: § 150.0(p), Certification by Manufacturers. Any pooi or spa healing system or equipment must be certified to have all of the following: a thermal efficiency thai complies with the Appliance Efficiency Regulations: an on-off switch mounted outside of the heater that al!owo; shutting off the heater without adjusting the thermostat setting: a permanent weatherproof plate or card with operating instructions: and must not use electric resistance heatino.' Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to al!ow for future solar heatina. Covers. Outdoor pools or spas that have a heat pump or gas heater must ha,1e a cover_ Directional Inlets and Time Switches for Pools. Pools must have directionai inlets ihat adequately mfx the pool water, and a lime switch that will allow all □umps to be set or □roorammed lo run onlv durino off-oeak electrlc demand periods, Pilot Light Natural gas pool and spa heaters must not have a conUnuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing. flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: § 150.0(k)1A: § 150.0(k)1B: § 150.0(k)1C, § 150.0(k)1D: § 150.0(k)1E §1500(k)1F § 150.0(k)1G: § 150.0(k)1H: § 150.0(k)11: § 150.0(k)2A, § 150.0(k)2B: § 150.0(k)2C: § 150.0(k)2D, § 150.0(k)2E § 150.0(k)2F, lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of§ 110.s· Luminaire Efficacy. All installed luminaires must meet the requiremenis in Table 150.0-A, Blank Electrical Boxes. The number of electricai boxes that are more than five feet above the finished floor and do not contain a luminaire or other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. Electronic Ballasts for Fluorescent Lamps. Ballasts for f!uoresceni lamps rated 13 watts or greater must be electronic and must have an outout freauencv no less than 20 kHz. Night Lights, Step Lights, and Path Lights. Night lights, step ligl1ts and patll lights are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens. Lighting lntegra[ to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of G 150_0(k).' Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8: ----------------------~-----------1 Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JAB elevated temperature requirements, including marking requirements. must not be installed in enclosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to comply with Table 150.0-A or be conirolled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no more than 150 !umens, and are equipped with controls that automtttically tum the lighting off when the drawer, cabinet or linen closet is closed. Interior Switches and Controls. All ior.vard phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems: Interior Switches and Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manual[y turned ON and OFF.~ Interior Switches and Controls. Controls and equipment must be installed in accordance wltil manufacturer's instructions. Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to comply with~ 150.0{k}. Interior Switches and Controls, Lighting controls must comply with the applicable requirements of§ 110.9. >-E a::i 0 0 (.) E w s::t-0 0::: N () Q) st <( N -CD o__ f--w ::8 -CD 0::: Q) Ol O>@l o__ -- $ _c ~ () $ C N (ll $ ~ I-s (/) w 0::: :::, (/) <( w 2: >-0::: 0 I- <( 0 z...- UJ !;;: 0 <( LL 2:0 ~...- N 1- WW _J w I-I I-(/) :::, 00 0 0 <( -a Cl) N -cm (/) D<( ~o C 2 - ---""O 0 CD <ll (/) -, ..Q ,__ "' .!!!. ~ st~ a, "' -NO <l) Cl) ---, Cl) C") UJ 0::: ~ 0 0) 0 N <( {D "' t---st ' 00 00 00 ~ st ~ t---~ UJ z 0 I CL MM-1 - A ,:;;- - - 1 -· ' ; ELECTRICAL NOTES 1. 2. 3 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. PROVIDE A 125 VOLT 15 OR 20 AMP RECEPTACLE WITHN 25" OF HEATING OR AIR CONDITIONING EQUIPMENT. 210.63 CEC/2019 TWO SMALL APPLIANCE BRANCH CIRCUITS ARE REQUIRED FOR THE KITCHEN ;;ND LIMITED TO SUPPL YING WALL AND COUNTER SPACE OUTLETS FOR THE KITCHEN, PANTRY, BREAKFAST ROOM, Dl:J!NG ROOM, OR SIMILARAREAS. NOTE; THESE CIRCUITS CANNOT SERVE OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, !JISHWASHERS OR MICROWAVES -ONLY THE REQUIRED COUNTERTOP/WALL OUTLETS INCLUOIN~ THE REFRIGERATOR. CEC 210.11(C)(1) & 21052(8) A DEDICATED MINIMUM 20-AMP CIRCUIT IS REQUIRED TO SERVE THE REQUIRED BATHROOM OUTLETS. THS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENTWITHN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED.) CEC 210.11 (C)(3) AND 210.52(0) A MINIMUM 10 AMP SMALL APPLIANCE BRANCH CIRCUITS SHALL BE PROVIDED FOR ALL RECEPTACLE OUTLETS IN THE KITCHEN, DINING AREA, PANTRY, OR OTHER SIMILAR AREAS (CEC 210.11 (C) (1)) AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY LAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVENO OTHER OUTLETS. (CEC 210. 11(C) (2)) IN EVERY DWELLNG UNITE, FIXED APPLIANCES SUCH AS FOOD WASTE GRINDERS, DISHWASHERS, WASHING MACHINES, DRYERS, LAUNDRY TRAY LOCATIONS BUILT-IN RFFHGERATORS OR FREEZERS, FURNACES, AC UNITS, BUILT-IN HEATERS OR ANY OTHER FIXED APPLIANCE WITH A MOTOR OF M-<HJ>. OR LARGER SHALL BE ONA SEPARATE 20 AMP. BRANCH CIRCUIT. 125-AND 250-VOLT RECEPTACLES INSTALLED OUTDOORS IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. (CEC 406.8 (8) (11). TAMPER RESISTANT RECEPTACLES AT ALL 124 VOLT, 15 AND 20 AMP RECEPTACLES. CEC 406.11 AFCI PROTECTED RECEPTACLES IN FAMILY ROOM, DINNG ROOM. LIVING ROOM, PARLORS, LIBRARIES, DENS, BEDROOMS. SUNROOMS, RECREATING ROOMS, CLOSETS, HALLWAYS, OR SIMII..AR ROOMS OR AREAS PER CEC 210 12(6) SMOKE ALARMS SHALL RECEIVE THEIR PHMARY POWER FROM THE BUILONG WIRING, NTERCONNECTED, AND WIRED ON A LIGHTNG CIRCUIT WITH BATTERY BACKUP. EXISTNG AREAS MAY BE SOLELY BATTERY OPERATED. SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN A 36" HORIZONTAL PATH FROM THE SUPPLY OR RETURN REGISTERS OF A HEATING OR COOLING SYSTEM. R314 CRC/2019 CARBON MONOXIDE ALARMS: SAME REQUIREMENTS AS SMOKE ALARMS EXCEPT NOT REQUIRED IN BEDROOMS. R315 CRC/2019 ELECTRICAL SPECS APPLIANCES DESIGNER TO BE FIXED N POSITION SHALL BE SECURELY FASTEN IN PLACE SUPPORTS FOR APPLIANCES SHALL BE DESIGNED AND CONSTRUCTED TO SUSTAIN VERTICAL ANO HORIZONTAL LOADS WITHIN THE STRESS LIMITATIONS SPECIFIED IN THE BUILDING CODE 303.4 CMC / 2019 (SEISMIC BRACING FOR GAS APPLIANCES.) APPLIANCES INSTAI.LED IN GARAGES OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE SHALL BE GUARDED AGAINST BY INSTALLED BEHIND PROTECTIVE BARRIERS OR ELEVATED OR OUT OF THE NORMAL PATH OF VEHICLES. NSTALL A 4" DIAMETER BOLLARD (FILLED W/ CONCRETE) EMBEDDED 36" INTO 12" DIAMETER FOOTNG IN FRONT OF APPLIANCE OR PROVIDE A DETAIL AND OR CALCULATION FROM AN ENGINEER FOR REVIEW 604.1 CMC / 2019 APPLIANCES DESIGNER TO BE FIXED IN POSITION SHALL BE SECURELY FASTEN IN PLACE. SUPPORTS FOR APPLIANCES SHALL BE DESIGNED AND CONSTRUCTED TO SUSTAIN VERTICAL ANO HORIZONTAL LOADS WITHIN THE STRESS LIMITATIONS SPECIFIED IN THE BUILDING CODE. 303.4 CMC / 2019 (SEISMIC BRACING FOR GAS APPLIANCES.) ALL STEEL REBARS MEASURING 1/2" OR MORE IN DIAMETER AND 20' OR LONGER N LENGTH THAT IS ENCASED IN NOT LESS THAN 2 INCHES OF CONCRETE SHALL BE BONDED TO THE BUILDNG'S GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 250 (ELECTRICAL SUBCOOE) SECTION 250.52(A)(3). THE"UNDER" GROUND CAN BE 20 L.F. OF# 2 OR #4 COPPER WIRING LAID INSIDE THE FOOTING AND THE SAME WIRE IS LONG ENOUGH TO REACH TO THE LOCATION OF THE MAIN ELECTHCAL PANEL OF THE HOUSE UFER GROUND CAN BE (1) L-SHAPED PIECE OF #4 STEEL REBAR CONNECTED TO THE OTHER STEEL REBAR IN THE FOOTING AND STICKING OUT IN SUFFICIENT LENGTH FOR CONNECTION AT THE LOCATION OF THE MAIN ELECTRICAL PANEL OF THE HOUSE NOTE SWITCHES, CONTROLLER, THERMOSTAT, ETC MOUNTING HEIGHT@ MNIMUM 15" TO MAXIMUM 48" MECHANICAL NOTES 1. IN LIEU OF NATURAL VENTILATION IN BATHROOMS CONTAINING A BATH AND/OR SHOWER AND SIMILAR ROOMS, A MECHANICAL SYSTEM COMPLYING WITH CMC 403.7 TABLE 4-1 AND CBC 1203.4.2.1 AND 1203.1 MAY BE PROVIDED. 2. PROVIDED TOILET ROOMS WITH A MECHANICALLY OPERATED EXHAUST SYSTEM TO THE OUTSIDE WHICH PROVIDES A COMPLETE AIR CHANGE EVERY 15 MINUTES. C.B.C. SECTION 1202.2.1. 3. DRAWINGS FOR HVAC WORK ARE DIAGRAMATIC SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWING SHALL NOT BE SCALED FOR EXACT MEASUREMENT, REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIOS. PROVIDE ALL DUCTWORK, MATERIALS, CONNECTIONS, ACCESSORIES, FITTINGS, OFFSETS, TRANSITIONS, DAMPERS AS REQUIRED FOR A COMPLETE WORKABLE SYSTEM. 4 ALL EQUIPMNENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND APPROVED LISTING. ALL EQUIPMENT, PIPING AND SUPPORTS SHALL BE RESTRAINED IN ACCORDANCE WITH THE LATEST EDITION OF THE "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS" BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA). ALL EQUIPMENT SHALL BE ANCHORED TO RESIST THE LATERAL FORCE REQUIREMENTS OF CHAPTER 16 OF THE 2012 INTERNATIONAL BUILDING CODE 5. COORDINATE THE INSTALLATION OF THE HVAC SYSTEM WITH ALL OTHER TRADES PRIOR TO FABRICATION OR INSTALLATION. COORDINATE THE LOCATIONS OF PENETRATIONS AND FINAL LOCATION OF ALL EQUIPMENT WITH THE GENERAL CONTRACTOR. PROVIDE EQUIPMENT WEIGHTS, EQUIPMENT DIMENSIONS, PLATFORM SIZES & LOCATIONS, CURB SIZES & LOCATIONS, CONCRETE PAD SIZES AND LOCATIONS AST REQUIRED. COORDINATE LOCATIONS OF GAS & CONDENSATE LINES WITH PLUMBING CONTRACTOR COORDINATE LOCATIONS OF POWER DISCONNECTS, ANO CONTROL CONDUIT WITH THE ELECTRICAL CONTRACTOR COORDINATE LOCATIONS OF ALL DIFFUSERS, REGISTERS, AND GRILLES WITH ARCHITECTURAL PLANS, ELECTRICAL LIGHTING PLANS AND ARCHITECTURAL ELEVATIONS. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. DETAILS FOR EQUIPMENT PADS, PLATFORMS, AND FLASHING SHALL BE AS INDICATED BY THE ARCHITECTURAU STRUCTURAUCIVIL DRAWINGS, UNLESS NOTED OTHERWISE. ALL EQUIPMENT, DUCTS, PIPING, SUPPORTS, AND OTHER DEVICES OUTSIDE OF THE BUILDING OR EXPOSED TO WEATHER, SHALL BE COMPLETELY WEATHER-PROOFED. OUTSIDE AIR INTAKES SHALL BE ATLEAST 10 FT. AWAY OR 3 FT. BELOW ANY VENT OR EXHAUST DISCHARGE. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. DUCTWORK SHALL BE CONSTRUCTED, ERECTED, INSULATED AND TESTED IN ACCORDANCE CHAPTER 6 OF THE 2012 INTERNATIONAL MECHANICAL CODE. ALL EXHAUST FANS SHALL BE EQUIPED WITH A BACK DRAFT DAMPER. DUCT AND AIR TRANSFER PENETRATIONS THRU BUILDING ASSEMBLIES REQUIRING PROTECTION SHALL BE PROTECTED WITH FIRE DAMPERS, SMOKE DAMPERS, COMBINATION SMOKE/FIRE DAMPERS AND CEILING RADIATION DAMPERS IN ACCORDANCE WITH SECTION 607 OF THE INTERNATIONAL MECHANICAL CODE DUCTS NOT REQUIRING DAMPERS SHALL COMPLY WITH SECTION 714 & 717 OF THE 2012 INTERNATIONAL BUIDLING CODE. INSTALL SMOKED DETECTORS AND PROVIDE FOR SMOKE DETECTION AND AUTOMATIC SHUT-OFF OF ALL AIR HANDLING EQUIPMENT IN ACCORDANCE WITH SECTION 606 OF THE INTERNATIONAL MECHANICAL CODE. UNLESS NOTED OTHERWISE, ALL LINE VOLTAGE WIRING, CONDUIT, FINAL CONNECTIONS, DISCONNECTS, STARTERS, AND OVER CURRENT PROTECTION DEVICES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AS INDICATED ON THESE MECHANICAL DRAWINGS AND/OR ELECTRICAL DRAWINGS AND/OR ELECTRICAL SECTION OF THE SPECIFICATIONS. INSTALL ALL LOW VOLTAGE HVAC CONTROL WIRE AND DEVICES PER PLAN. ALL WIRE SHALL BE IN CONDUIT PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. PROVIDE OWNER WITH THREE COPIES OF A CERTIFIED AIR BALANCE REPORT PREPARED IN BY A THIRD PARTY CERTIFIED BY THE AABC OR NEBB. TEST, ADJUST AND BALANCE THE HVAC SYSTEM IN ACCORDANCE WITH AABC OR NEBB PROCEDURES. PROVIDE START-UP/TEST REPORTS FOR ALL AIR HANDLING EQUIPMENT, FANS, AND REFRIGERATION EQUIPMENT. TEST AND VERIFY PROPER OPERATION OF ALL MAKE-UP AIR/EXHAUST AIR INTERLOCK SYSTEMS AND THEIR SEQUENCES OF OPERATION. BALANCE ALL AIR FLOWS WITHIN 5% OF DESIGN VALUES. PERMANENTLY MARK BALANCE POSITION OF ALL REGULA TING DEVICES. PROVIDE OWNER WITH THREE SETS OF AS-BUILT PLANS AND OPERATIONS AND MAINTENANCE MANUALS. CLEARLY IDENTIFY ALL EQUIPMENT WITH PERMANENT PLASTIC OR METAL LABELS/TAGS (PEN MARKING NOT ACCEPTABLE). PROVIDE ONE YEAR WARRANTY ON ALL LABOR, PARTS AND MATERIALS. ANY CHANGE OR DEVIATION FROM THESE PLANS OR SPECIFICATIONS SHALL REQUIRE THE WRITTEN APPROVAL OF THE ENGINEER PRIOR TO COMMENCEMENT OF SUCH WORK. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. PLUMBING NOTES THE ENTIRE INSTALLATION SHALL CONFORM TO THE REQUIREMENiS OF THE 2019 UNIFORM PLUMBING CODE, 2019 INTERNATIONAL BUILDING CODE. 2019 INTERNATIONAL ENERGY cofJSERVATION CODE AND ALL OTHER APPLICABLE CODES AND REGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION. IN THE EVENT OF CONFLICT BETWEEM SPECIFICATIONS, CODES, AND REGULATIONS, THE MORE RESTRICT/VE SHALL APPLY. COORDINATE ENTIRE INSTALLATOIN OF THE PLUMBING SYSTEM WITH THE WORK OF OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATOIN. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. REPORT ANY DISCREPANCIES, IN WRITING, TO THE ENGINEER PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS WITH ALL CHANGES NOTED THEREON AT THE COMPLETION OF THE PROJECT IN ACCORDANCE WITH THE SPECIFICATIONS. PROVIDE ONE YEAR WARRANTY ON ALL PARTS AND LABOR. THE DRAWINS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOP~ CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE THE BEST ARRANGEMENT OF ALL DUCT, PIPE, CONDUIT, ETC ALL CUTTING AND PATCHING OF THE EXISTING STRUCTURE SHALL BE PROVIDED UNDER OTHER SECTIONS OF THE WORK. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. ALL HOT WATER PIPING AND RECIRCULATION PIPING (EXCEPT RUNOUTS 12FT. OR SHORTER TO INDIVIDUAL FIXTURES) SHALL BE INSULATED TO MEET THE REQUIREMENTS OF THE2019 INTERNATIONAL ENERGY CONSERVATION CODE CONDENSATE DRAINS SHALL BE PROVIDED FOR EACH AIR CONDITIONING UNIT.HORIZONTAL CONDENSATE DRAINS ABOVE ANY CEILING SHALL BE INSULATED WITH MIN. 3/8" THICK CLOSED CELL INSULATION. PIPING: WASTE, VENT, AND STORM DRAIN PIPING SHALL BE CO-EXTRUDED PVC ASTM 01785) PIPE 1. WATER PIPE SHALL BE PVC PIPE 2. CCONDENSATE PIPING SHALL BE CO-EXTRUDED PVC (ASTM D1785) PIPE 3 INSIDE GAS PIPING SHALL BE BLACK IRON ASTM D1785 WITH MALLEABLE IRON FITTINGS. OUTSIDE SHALL BE GALVANIZED IRON ASTM D1785 WITH GALVANIZED FITTINGS. GAS LINE TO BE PAINTED GRAY IN COLOR. A 24 HOUR METERED GAS TEST SHALL BE REQUIRED. 4 ALL PIPING NOT ENCLOSED IN CONDITION SPACE OR AT EXTERIOR WALLS SHALL BE INSULATED. 5. PIPING: PVC ASTM D1785, SCHEDULE 80 AND CPVC PIPING WITH SOLVENT WELD FITTINGS SHALL BE USED WHERE PERMITTED BY CODE/ LOCAL AUTHORITIES ALL VENTS OR EXHAUSTS SHALL BEAT LEAST 10 FT. AWAY OR 3 FT. ABOVE ANY WINDOW, DOOR, OPENING, OR AIR INTAKE. CLEANOUTS SHALL BE INSTALLED PER THE UNIFORM PLUMBING CODE. PROVIDE WATER TIGHT FLASHINGS WHEREVER PIPES PASS THROUGH EXTERIOR WALLS, ROOFS, OR FLOORS. PROVIDE ISOLATION FOR ALL PIPES THAT COME IN CONTACT WITH THE STRUCTURE LOCATION OF EXISTING UTILITIES AND POINTS OF CONNECTION ARE APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTHS OF EXISTING UTILITIES AND SERVICES PRIOR TO STARTING WORK OF THIS SECTION. IF INDICATED POINTS OF CONNECTION CANNOT BE MADE TO EXISTING UTILITIES AS FOUND. THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO INSTALLING ANY WORK WHICH MAY BE AFFECTED. VALVES SHALL BE NIBCO, JENKINS, HAMMOND, RED & WHITE OR APPROVED EQUAL SERVICE PRESSURE SHALL BE SUITEABLE FOR SERVICE INTENDED. THE MAIN WATER SHUT OF VALVE SHALL BE A FULL PORT BALL TYPE AND APPROVED FOR SERVICE INTENDED. CONTRACTOR SHALL PROVIDE ALL SHUT OFF VALVES AS NECESSARY TO ISOLATE ANY EQUIPMENT, PLUMBING ITEMS, OR FIXTURES, THAT MAY NEED SERVICING OR ARE SUBJECT TO FAILURE WHETHER OR NOT SUCH VALVES ARE SHOWN ON THE DRAWINGS. PROVIDE HANGERS AND SUPPORTS AS REQUIRED. PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE. CONTRACTOR IS RESPONSIBLE FOR HIS OWN TRENCHING, BACKFILL, AND COMPACTION OF TRENCHES NECESSARY TO COMPLETE HIS SCOPE OF WORK. BACKFILLED TRENCHES SHALL BE RETURNED TO THEIR ORIGINAL GRADE UNLESS NOTED OTHERWISE CONTRACTOR SHALL AFFIX A MAINTENANCE LABEL TO ALL EQUIPMENT REQUIRING ROUTINE MAINTENANCE AND SHALL PROVIDE MAINTENANCE AND OPERATIONAL MANUALS IN ACCORDANCE WITH THE SPECIFICATIONS. 21. ALL EQUIPMENT THAT REQUIRES KEYS OR SPECIAL TOOLS TO OPERATE SHALL SUPPLY THE OWNER WITH TWO OF ANY SUCH KEYS OR TOOLS FOR EACH PIECE OF EQUIPMENT THAT REQUIRE THE SAME. 22. ANY CHANGE OR DEVIATION FROM THESE PLANS OR SPECIFICATIONS SHALL REQUIRE THE APPROVAL, IN WRITING, OF THE ENGINEER PRIOR TO COMMENCEMENT OF SUCH WORK. 23. ALL PLUMBING, ELECTRICAL, AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE. ALL LINES NOT CONCEALED SHALL BE SECURED 6" OFF THE FLOOR AND¾" FROM THE WALLS USING STANDOFF BRACKETS. 24. AN APPROVED BACKFLOW PREVENTOR SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY AND SOURCE OF COMTAMINATION. 25. WATER SUPPLY CARBO RA TORS SHALL BE PROTECTED BY AN APPROVED REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTOR THE RELIEF VALVE SHALL DRAIN IN-DIRECTLY TO A FLOOR SINK WITH A 1" MIN. AIR GAP. STRUCTURAL NOTES 1. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. ALL ROOF GUTTERS AND DOWNSPOUTS SHALL BE CONSTRUCTED OF NONCOMBUSTIBLE MATERIALS. 2. DRIP EDGE FLASHING USED AT THE FREE EDGES OF ROOFING MATERIALS SHALL BE NON-COMBUSTIBLE 3. VALLEY FLASHINGS SHALL BE NOT LESS THAN 0.019-INCH (NO 26 GALVANIZED SHEET GAGE) CORROSION- RESISTANT METAL INSTALLED OVER A MINIMUM 36-INCH-WIDE UNDERLAYMENT CONSISTING OF ONE LAYER OF NO. 72 ASTM CAP SHEET RUNNING THE FULL LENGTH OF THE VALLEY. 4. TURBINE ATTIC VENTS SHALL BE EQUIPPED TO ALLOW ONE-WAY DIRECTION ROTATION ONLY AND SHALL NOT FREE SPIN IN BOTH DIRECTIONS. GLAZING FRAMES MADE OF VINYL MATERIALS SHALL HAVE WELDED CORNERS, METAL REINFORCEMENT IN THE INTERLOCK AREA, AND BE CERTIFIED TO THE MOST CURRENT EDITION OF ANSI/AAMAINWWDA 101/1.S.2 STRUCTURAL REQUIREMENTS. BMP NOTES STORM WATER QUALITY NOTES -CONSTRUCTION BMP'S THIS PROJECT SHALL COMPLY WITH ALL CURRENT REQUIREMENTS OF THE STATE PERMIT: CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD (SDRWQCB), SAN DIEGO MUNICIPAL STORM WATER PERMIT, THE LAND DEVELOPMENT CODE, AND THE STORM WATER STANDARDS MANUAL. NOTES BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION BMP'S. 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP OF ALL SLIT AND MUD ON ADJACENT STREET(S), DUE TO CONSTRUCTION VEHICLES OR ANY OTHER CONSTRUCTION ACTIVITY, AT THE END OF EACH WORK DAY, OR AFTER A STORM EVENT THAT CAUSES A BREACH IN INSTALLED CONSTRUCTION BMP'S WHICH MAY COMPROMISE STORM WATER QUALITY WITHIN ANY STREET(S). A STABILIZED CONSTRUCTION EXIT MAY BE REQUIRED TO PREVENT CONSTRUCTION VEHICLES OR EQUIPMENT FROM TRACKING MUD OR SILT ONTO THE STREET. 2. 3. 4. 5. 6. ALL STOCK PILES OF SOIL AND/OR BUILDING MATERIALS THAT ARE INTENDED TO BE LEFT FOR A PERIOD GREATER THAN SEVEN CALENDAR DAYS ARE TO BE COVERED. ALL REMOVABLE BMP DEVICES SHALL BE IN PLACEATTHE END OF EACH WORKING DAY WHEN FIVE DAY RAIN PROBABILIYT FORECAST EXCEED 40%. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECT WHICH PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPROVEMENTS WHICH ARE TO BE POURED IN PLACE ON SITE THE CONTRACTOR SHALL RESTORE ALL EROSION/SEDIMENT CONTROL DEVICES TO WORKING ORDER AFTER EACH RUN-OFF PRODUCING RAINFALL OR AFTER ANY MATERIAL BREACH IN EFFECTIVENESS. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTIVITY MUST BE PROTECTED AGAINST EROSION AND SEDIMENT TRANSPORT AT ALL TIMES. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPTMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRONMENT. 1 2 3. 4 5 6. 7. 8. 9. 10. 11. 12. 13. 14. GENERAL NOTES PROVIDE BACKING AS REQUIRED FOR INSTALLATION OF EQUIPMENT, FIXTURES, ACCESSORIES, AND CASEWORK. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL, IF REQUESTED, BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. WHERE SURFACES ARE TO BE PAINTED, USE TWO COATS (PLUS PRIMER, IF NEW CONSTRUCTION) MINIMUM. COMPLY WITH PAINT MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND APPLICATION. CONTRACTOR TO PROVIDE FINISH SAMPLES FOR ARCHITECT AND OWNER APPROVAL FOR· A ROOFING 8. CABINETRY (DOOR PANEL MIN) C. ELECTRICAL SWITCHPLATES AND SWITCHES D. CONCRETE FLOORING E. EXTERIOR PAVING MATERIAL F. WALL & CEILING PAINT BRUSH-OUTS G. SOFFIT VENTS H. WOOD FINISH ON SITE WALLS I. FASCIA SECTION -4' MIN J. CEMENT PLASTER TEXTURE CONTRACTOR TO PROVIDE SHOP DRAWINGS/SUBMITTALS FOR: A. INTERIOR WOOD DOORS B. EXTERIOR WINDOWS & DOORS C. CABINETRY D. AS REQUIRED BY CIVIL AND STRCUTURAL ENGINEERS ALL EARTHWORK AND SITE DRAINAGE, INCLUDING PARTIAL BASEMENT BACKFILL, PIER DRILLING, OR FOOTING EXCAVATIONS, PREPARATION OF SUBGRADE BENEATH SLAB-ON-GRADE. PLACEMENT AND COMPACTION OF ENGINEERED FILL, AND SURFACE DRAINAGE SHOULD BE PERFORMED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT AND, SHOULD BE PROVIDED AT LEAST 48 HOURS ADVANCE NOTIFICATION. ANY EARTHWORK OPERATIONS AND SHOULD BE PRESENT TO OBSERVE AND/ OR TEST AS NECESSARY THE EARTHWORK AND FOUNDATION INSTALLATION PHASES OF THE PROJECT. AN ELECTRONICALLY SIGNED AND REGISTERED INSTALLATION CERTIFICATE(S) (CF2R) POSTED BY THE INSTALLING CONTRACTOR SHALL BE SUBMITTED TO THE FIELD INSPECTOR DURING CONSTRUCTION AT THE BUILDING SITE A REGISTERED CF2R WILL HAVE A UNIQUE 21-DIGIT REGISTATION NUMBER FOLLOWED BY FOUR ZEROS LOCATED AT THE BOTTOM OF EACH PAGE. THE FIRST 12 DIGITS OF THE NUMBER WILL MATCH THE REGISTRATION NUMBER OF THE ASSOCIATED CF1R. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL FORMS CF2R IS REVIEWED AND APPROVED. AN ELECTRONICALLY SIGNED AND REGISTERED CERTIFICATE(S) OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (CF3R) SHALL BE POSTED AT THE BUILDING SIGNED AND REGISTERED CERTIFICATE(S) OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (CF3R) SHALL BE POSTED AT THE BUILDING SITE BY A CERTIFICATE HERS RATER A REGISTERED CF3R WILL HAVE A UNIQUE 25' DIGIT REGISTRATION NUMBER LOCATED AT THE BOTTOM OF EACH PAGE. THE FIRST 20 DIGITS OF THE NUMBER WILL MATCH THE REGISTRATION NUMBER OF THE ASSOCIATED CF2R. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL CF3R IS REVIEWED AND APPROVED. LIGHTING IN BATHROOMS SHALL HAVE ALL HIGH EFFICACY LUMINAIREAND AT LEAST ONE LUMINAIRE MUST BE CONTROLLED BY A VACANCY SENSOR. ALL THE INSTALLED WATTAGE OF LUMINAIRES IN KITCHENS SHALL BE HIGH EFFICACY AND SHALL HAVE A MANUAL ON/OFF IN ADDITION TO A VACANCY SENSOR OR DIMMER UNDER CABINET LIGHTING SHALL BE SWITCHED SE PARA TEL Y. LIGHTING IN GARAGE, LAUNDRY ROOMS, AND UTILITY ROOMS; ALL LUMINAIRES SHALL BE HIGH EFFICACY AND AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SWITCH ALL LUMINAIRES SHALL BE HIGH EFFICACY AND SHALL HAVE A MANUAL ON/OFF IN ADDITION TO A VACANCY SENSOR OR DIMMER OUTDOOR LIGHTING; ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDING ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES OR MUST BE CONTROLLED BY A MOTION SENSOR AND CONTROLLED BY ONE OF THESE AUTOMATIC CONTROL TYPES; PHOTOCONTROL AND A MOTION SENSOR, ASTRONOMICAL TIME CLOCK, OR ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) SHOWER COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A NONABSORBANT SURFACE THAT EXTENDS TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR EGRESS NOTES 1. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. THE MINIMUM NET CLEAR OPENING FOR EMERGENCY ESCAPE GRADE-LEVEL OPENINGS SHALL BE 5 SQUARE FEET. 2. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE FOLLOWING DIMENSIONS A MINIMUM CLEAR OPENING HEIGHT SHALL BE 24 INCHES. (CRC R310.12) THE MINIMUM CLEAR OPENING WIDTH SHALL BE 20 INCHES. (CRC R311.1.3) THE MAXIMUM SILL HEIGHT IS 44 INCHES. 3. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. ADDITIONAL NOTES A REFER TO STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, CIVIL AND LANDSCAPE DRAWINGS FOR EXTENT OF WORK 8. CONTRACTOR SHALL INVESTIGATE ALL UNDERGROUND UTILITIES AND VERIFY LOCATION AS INDICATED ON THESE PLANS AND/OR OWNER'S RECOR DRAWINGS AS FIRST ORDER OF WORK. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. C. PROVIDE TEMPORARY BARRICADES AND OTHER SUCH PROTECTION AS REQUIRED TO PROTECT THE OWNER'S PERSONNEL AND GENERAL PUBLIC FROM INJURY DUE TO SELECTIVE DEMOLITION WORK AND ALLOW FOR FREE AND SAFE PASSAGE FROM OCCUPIED PORTIONS OF BUILDINGS. D. REMOVE PROTECTION AT COMPLETION OF WORK PROTECT STRUCTURE, UTILITIES, SIDEWALKS, PAVEMENTS, AND LANDSCAPING, FROM DAMAGE DURING CONSTRUCTION. E. F. G. H. I J. K. MAINTAIN (E) UTILITIES INDICATED TO REMAIN, KEEP IN SERVICE AND PROTECT FROM DAMAGE DURING CONSTRUCTION. OBTAIN WRITTEN AUTHORIZATION FROM OWNER AND/OR AUTHORITY HAVING JURISDICTION PRIOR TO INTERRUPTING UTILITIES SERVING OCCUPIED FACILITIES. CREATION OF DUST SHALL BE MINIMIZED BY SPRINKLING OR OTHER EPA APPROVED METHOD. DO NOT USE WATER WHEN IT MAY CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS. REFER TO CONSULTANT DRAWING FOR FURTHER INFORMATION ON THE ABANDONMENT OR REMOVAL OF CERTAIN UNDERGROUND PIPES OR CONDUITS. RECORD DRAWINGS OF SITE UTILITIES AND BUILDING ARE AVAILABLE AT DISTRICT FOR REVIEW BEFORE STARTING ANY CONSTRUCTION WORK, FENCE FOUNDATION LOCATIONS NEED TO BE COORDINATED WITH EXISTING AND NEW UNDERGROUND UTILITIES TO AVOID ANY CONFLICTS DURING CONSTRUCTION. CONTRACTOR TO INFORM ARCHITECT IMMEDIATELY OF ANY CONFLICTS OR DISCREPANCIES. - 1. 2. 3. 4. 5 6. 7. 8. 9 10. 11. 12 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. GENERAL NOTES THE DESIGNER ASSUMES NO RESPONSIBILITY FOR COMPLETENESS OF PLANS FOR BID PURPOSES PRIOR TO ISSUANCE OF THE BUILDING PERMIT. THE INTENT OF DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL LABOR, MATERIAL SERVICES NECESSARY FOR THE NECESSARY COMPLETION OF ALL WORK SHOW, DESCRIBED OR REASONABLY IMPLIED BUT NOT LIMITED TO THAT EXPLICITLY INDICATED IN THE CONTRACT DOCUMENTS THE DESIGNER APPROVAL OF SHOP DRAWINGS SHALL NOT RELIEVE THE GENERAL CONTRACTOR OR SUBCONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS UNLESS HE HAS, IN WRITING, CALLED THE DESIGNERS ATTENTION TO SUCH DEVIATIONS AT THE TIME OF SUBMISSION NOR SHALL IT RELIEVE HIM FROM RESPONSIBILITY FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS. ' ALL WORK SHALL CONFORM TO THE 2019 EDITION OF ALL THE CALIFORNIA BUILDING CODES ADOPTED AND AMENDED BY THE CITY. HANDICAP REQUIREMENTS, AND ANY OTHER CODE AND ORDINANCES ENFORCED BY THE CITY AND COUNTY OF SAN DIEGO GOVERNING AGENCIES. UNLESS OTHERWISE SHOWN OR NOTED TYPICAL DETAILS AND GENERAL NOTES SHALL BE USED WHENEVER APPLICABLE. DIMENSIONS SHOWN IN FIGURES TAKES PRECEDENCE OVER DIMENSIONS SCALED FROM DRAWINGS. LARGE SCALE DRAWINGS ANO DETAILS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. UNLESS OTHER WISE NOTES OR INDICATED ALL DIMENSIONS THE PLANS SHALL BE FROM CENTERLINE OF THE COLUMN OR STUD, OR FACE OF Fl~ISH WALL THE CONTRACTOR AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AND SURROUNDING AREA FREE FROM DUST AND DEBRIS. THE WORK SHALL BE IN CONFORMANCE WITH THE AIR AND WATER POLLUTION CONTROL STANDARDS AND REGULATIONS OF THE STATE DEPARTMENT OF HEALTH. CONSTRUCTION DEBRIS AND WASTES SHALL BE DEPOSITED AT AN APPROPRIATE SITE. THE CONTRACTOR SHALL INFORM THE CITY ENGINEER OF THE LOCATION OF DISPOSAL SITES TO BE USED. THE SITE MUST ALSO FULFILL THE REQUIREMENTS OF THE GRADING ORDINANCES. THE CONTRACTOR SHALL CHECK AND VERIFY SIZE AND LOCATION OF DUCT OPENINGS AND PLUMBING RUNS WITH MECHANICAL CONTRACTOR BEFORE FORMING WALLS, FLOORS, ETC. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS. PLUMBING, ELECTRICAL WORK. ACCESS PANELS TO BE APPROVED BY THE DESIGNER. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION IN ACCORDANCE WITH CHAPTER 3306. CBC IF TRENCHES OR EXCAVATIONS 5' OR MORE IN DEPTH ARE REQUIRED OBTAIN NECESSARY ISSUANCE OF A BUILDING OR GRADING PERMIT. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. THE APPLICANT SHALL HAVE EVIDENCE OF CURRENT WORKMAN'S COMPENSATION INSURANCE COVERAGE O THE FILE WITH THE DEPARTMENT IN COMPLIANCE WITH THE CITY LABOR CODE. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB SITE PRIOR TO THE BEGINNING OF CONSTRUCTION AND REPORT AND DISCREPANCIES TO THE DESIGNER. ALL NOISE BARRIER BATTS (SOUND INSULATION) SHALL BE NON-COMBUSTIBLE. UNLESS NOTED OTHERWISE. ALL NON CONCRETE SURFACES TO BE PAINTED SHALL RECEIVE A MINIMUM OF THREE COATS OR TWO COATS ON PRIMER CONCRETE TO BE ON COAT OVER PRIMER. THE CENTER RECEPTACLE OUTLETS SHALL NOT BE LESS THAN 15 INCHES ABOVE THE FLOOR OR WORKING AREA. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATION EQUIPMENT, SHALL NOT BE LESS THAN 3-FEET NOR MORE THAN 4-FEET ABOVE THE FLOOR OR WORKING PLATFORM. THE CENTER OF THE FIRE ALARM INITIATION DEVICES (BOXES) (IF PROVIDED) SHALL BE LOCATED 48 INCHES ABOVE THE LEVEL FOR THE FLOOR WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. CITY APPROVED CONDITIONS OF APPROVAL FOR THIS PROJECT AND RECORDED BY THE CITY ARE TO BE CONSIDERED A PART OF THESE PLANS AND SHALL BE APPLIED. THE GENERAL CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR ALL MEANS, METHODS & PROCEDURES FOR THE COMPLETE CONSTRUCTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF ALL PERSONS ON THE JOB SITE PER CURRENT OSHA REQUIREMENTS. ALL WEATHER -EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTIVE BARRIER TO PROTECT THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. CBC 1708 ITEMS OF A CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, OR ELECTRICAL NATURE MAY NOT APPEAR ON THE ARCHITECTURAL DRAWINGS. SEE APPROPRIATE DRAWINGS FOR THESE ITEMS. THE FIRE SUPPRESSION SYSTEM, IE AUTOMATIC SPRINKLERS, HOOD-DUCT SYSTEM, WET STANDPIPES, AND HYDRANTS SHALL NOT BE INSTALLED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED BY THE FIRE & LIFE SAFETY GOVERNING BODY. FOOD HANDLING FACILITIES SHALL COMPLY WITH ALL LOCAL HEALTH DEPARTMENT REQUIREMENTS & CALIFORNIA UNIFORM RETAIL FOOD FACILITIES LAW. PRIOR TO BIDDING. THE GENERAL CONTRACTOR SHALL VISIT & INSPECT THE SITE TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS AFFECTING THE NEW WORK. THE GENERAL CONTRACTOR SHALL NOT DISPUTE, COMPLAIN, OR ASSERT THAT THERE IS ANY MISSUNDERSTANDING IN REGARDS TO LOCATION, EXTENT, NATURE, OR AMOUNT OF WORK TO BE PERFORMED UNDER THIS CONTRACT DUE TO THE CONTRACTOR'S FAILURE TO INSPECT THE SITE AND/OR FAILURE TO NSPECT THE CONTRACT DOCUMENTS. THE GENERAL CONTRACTOR & SUBCONTRACTORS ARE RESPONSIBLE FOR LOCATING & VERIFYING ALL EXISTING UNDERGROUND UTILITIES IN ALL AREAS OF THE NEW WORK PRIOR TO COMMENCEMENT OF EXCAVATION. EXISTING UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE ROUTING LOCATIONS AS BEST DETERMINED FROM EXISTING DRAWINGS & BY THE OWNER, BUT SHOULD NOT BE CONSTRUED TO REPRESENT ALL EXISTING UTILITIES ANY ALTERATIONS OF EXISTING FACILITIES TO ACCOMMODATE THE INSTALLATION OF NEW WORK SHALL BE REVIEWED BY THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. ALL EXISTING FINISHES OR MATERIALS DAMAGED OR DEMOLISHED DUE TO NEW CONSTRUCTION SHALL BE RESTORED TO THEIR ORIGINAL STATE OR REPLACED WITH NEW MATERIALS FINISHED TO MATCH EXISTING THE WORK INCLUDED UNDER THESE DRAWINGS CONSISTS OF ALL LABOR, MATERIALS, TRANSPORTATION, TOOLS AND EQUIPMENT NECESSARY FOR THE CONSTRUCTION OF THE PROJECT -LEAVING ALL WORK READY FOR USE. THE PLANS INCLUDE THE GENERAL EXTENT OF NEW CONSTRUCTION NECESSARY FOR THE WORK, BUT ARE NOT INTENDED TO BE ALL-INCLUSIVE. ALL NEW WORK NECESSARY TO ALLOW FOR A FINISHED JOB IN ACCORDANCE WITH THE INTENTION OF THE DRAWINGS IS INCLUDED REGARDLESS OF WHETHER SHOWN ON THE DRAWINGS OR MENTIONED IN THE NOTES. ANY ERRORS, OMISSIONS OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING. ALL WORK, MATERIALS AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES AND ORDINANCES, INCLUDING THE MOST RECENT REVISIONS, ADDITIONS. AMENDMENTS AND INTERPRETATIONS. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE THE CONTRACTOR SHALL REVIEW THE CONTRACT DOCUMENTS AND VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH ANY WORK. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON THE JOB SITE DURING ALL PHASES OF CONSTRUCTION FOR USE BY ALL TRADES AND SHALL PROVIDE ALL SUBCONTRACTORS WITH CURRENT CONSTRUCTION DRAWINGS AS REQUIRED. CONTRACTORS SHALL USE WRITTEN DIMENSIONS ONLY DO NOT SCALE DRAWINGS. DIMENSIONS ARE TO FACE OF STUD, UON. DIMENSIONS MARKED "CLR" SHALL BE TO FACE OF FINISHES. ALL DIMENSIONS NOTED V.I.F. ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. REPORT ANY VARIANCES TO THE ARCHITECT PRIOR TO PROCEEDING COORDINATE ALL ARCHITECTURAL WORK WITH STRUCTURAL, ELECTRICAL, AND MECHANICAL CONDITIONS BEFORE THE ORDERING OF, OR THE INSTALLATION OF, ANY ITEM OF WORK. INSTALL ALL FIXTURES, EQUIPMENT, AND MATERIALS PER MANUFACTURERS' RECOMMENDATIONS. FOLLOW MANUFACTURER'S INSTALLATION RECOMMENDATIONS AND STANDARD INDUSTRY AND BUILDING PRACTICES FOR SEALANT AND CAULKING LOCATIONS. THE GENERAL CONTRACTOR SHALL, ON A REGULAR BASIS, REMOVE ALL RUBBISH AND DEBRIS OF ALL SUBCONTRACTORS AND TRADES, AND SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING TO PREVENT ANY DEBRIS ORDUST FROM AFFECTING, IN ANYWAY, FINISHED AREAS IN OR OUTSIDE THE JOB SITE. YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER ex:, 0 0 z N 0) 0 <( (.) -I-"'O ro -.Cl C U) -;::: ro C (.) <C -en C ::::, 0 U) ,_ C & (]) <C --:, C") 'St 0) N PROJECT STATUS NO. DESCRIPTION DATE i--------------- DATE 2/1/2021 5:05:11 PM ,, AGENCY# DIG JOB# SA 20182 GENERAL NOTES G-002 ' SECTION 4.106 SITE DEVELOPMENT 4.106.1 GENERAL- PRESERVATION AND USE OF AVAILABLE NATURAL RESOURCES SHALL BE ACCOMPLISHED THROUGH EVALUATION AND CAREFUL PLANNING TO MINIMIZE NEGATIVE EFFECT ON THE SITE AND ADJACENT AREAS. PRESERVATION OF SLOPES, MANAGEMENT OF STORM WATER DRAINAGE AND EROSION CONTROLS HALL COMPLY WITH THIS SECTION. 4.106.2 STORM WATER - DRAINAGE AND RETENTION DURING CONSTRUCTION. PROJECT WHICH DISTURB LESS THAN ONE ACRE OF SOIL AND ARE NOT PART OF A LARGER COMMON PLAN OF DEVELOPMENT WHICH IN TOTAL DISTURBS ONE ACRE OR MORE, SHALL MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION. IN ORDER TO MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWING MEASURE HALL BE IMPLEMENTED TO PREVENT FLOODING OF ADJACENT PROPERTY, PREVENT EROSION AND RETAIN SOIL RUNOFF ON THE SITE. 1. RETENTION BASINS OF SUFFICIENT SIZE HALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. 2. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING AGENCY 3. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT ORDINANCE. 4.106.3 GRADING AND PAVING- CONSTRUCTION PLANS SHALL INDICATE HOW THE SITE GRADING OR DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. SWALES 2. WATER COLLECTION AND DISPOSAL SYSTEMS 3. FRENCH DRAINS 4. WATER RETENTION GARDENS 5. OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILDING AND AID IN GROUND WATER RECHARGE. EXCEPTION: ADDITIONS AND ALTERATIONS NOT ALTERING THE DRAINAGE PATH SECTION 4.303 INDOOR WATER USE 4.303.11 WATER CLOSETS- THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH. TANK -TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR TANK-TYPE TOILETS. 4.303.1.2 URINALS- THE EFFECTIVE FLUSH VOLUME OF URINALS SHALL NOT EXCEED 0.5 GALLONS PER FLUSH. 4.303.1.3 SHOWERHEADS- SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR SHOWERHEADS. MULTIPLE SHOWERHEADS SERVING ONE SHOWER WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. 4.303.1.4 FAUCETS- RESIDENTIAL LAVATORY FAUCETS. THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT EXCEED 1.5 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. PROVIDE LAVATORY FAUCETS WITH A MAXIMUM FLOW OF 1.2 GALLONS PER MINUTE (GPM). 4.303.1.4.2 LAVATORY FAUCETS IN COMMON AND PUBLIC USE AREAS. THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS INSTALLED IN COMMON AND PUBLIC USE AREAS (OUTSIDE OF DWELLINGS OR SLEEPING UNITS) IN RESIDENTIAL BUILDINGS SHALL NOT EXCEED 0.5 GALLONS PER MINUTE AT 60 PSI. 4.303.1.4.3 METERING FAUCETS WHEN INSTALLED IN RESIDENTIAL BUILDINGS SHALL NOT DELIVER MORE THAN 0.25 GALLONS PER CYCLE. 4.303.1.4.4 KITCHEN FAUCETS. THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2 2 GALLONS PER MINUTEAT60 PSI, AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. CALIFORNIA GREEN MANDATORY MEASURES 4.303.2 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURE§ AND FITTING SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1401.1 OF THE CALIFORNIA PLUMBING CODE. ALL PLUMBING FIXTURES AND FITTINGS WILL BE WATER CONSERVING AND WILL COMPLY WITH THE 2016 CGBSC. PER 2016 CGBSC, PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE (CPC). SECTION 4.304 OUTDOOR WATER USE 4.304.1 IRRIGATION CONTROLLERS. AUTOMATIC IRRIGATION SYSTEM CONTROLLERS FOR LANDSCAPING PROVIDED BY THE BUILDER AND INSTALLED AT THE TIME OF FINAL INSPECTION SHALL COMPLY WITH THE FOLLOWING: 1. CONTROLLERS SHALL BE WEATHER-OF SOIL MOISTURE-BASED CONTROLLERS THAT AUTOMATICALLY ADJUST IRRIGATION IN RESPONSE TO CHANGES IN PLANT'S NEEDS AS WEATHER CONDITIONS CHANGE. 2. WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS OR COMMUNICATION SYSTEMS THAT ACCOUNT FOR LOCAL RAINFALL SHALL HAVE A SEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATES WITH THE CONTROLLER(S). SOIL MOISTURE-BASED CONTROLLERS ARE NOT REQUIRED TO HAVE RAIN SENSOR INPUT 3. PERMANENT VACCUUM BREAKERS SHALL BE INCLUDED WITH ALL NEW HOSE BIBBS. SECTION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING- ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. SECTION 4.408 CONSTRUCTION WASTE REDUCTION. DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT- RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM 75 PERCENT OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH EITHER SECTION 4.408.2, 4.408.3, OR 4.408.4 OR MEET A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN- SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN IN CONFORMANCE WITH ITEMS 1 THROUGH 5. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL BE UPDATED AS NECESSARY AND SHALL BE AVAILABLE DURING CONSTRUCTION FOR EXAMINATION BY THE ENFORCING AGENCY. 1. IDENTIFY THE CONSTRUCTION AND DEMOLITION WASTE MATERIALS TO BE DIVERTED FROM DISPOSAL BY RECYCLING, REUSE ON THE PROJECT OR SALVAGE FOR FUTURE USE OR SALE. 2. SPECIFY IF CONSTRUCTION AND DEMOLITION WASTE MATERIALS WILL BE SORTED ON-SITE (SOURCE-SEPARATED) OR BULK MIXED (SINGLE STREAM). 3. IDENTIFY DIVERSION FACILITIES WHERE THE CONSTRUCTION AND DEMOLITION WASTE MATERIAL WILL BE TAKEN. 4. IDENTIFY CONSTRUCTION METHOD EMPLOYED TO REDUCE THE AMOUNT OF CONSTRUCTION AND DEMOLITION WASTE GENERATED. 5. SPECIFY THAT THE AMOUNT OF CONSTRUCTION AND DEMOLITION WASTE MATERIALS DIVERTED HALL BE CALCULATED BY WEIGHT OR VOLUME, BUT NOT BY BOTH. 4.408.3 WASTE MANAGEMENT COMPANY. UTILIZE A WASTE MANAGEMENT COMPANY, APPROVED BY THE ENFORCING AGENCY. WHICH CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF CONSTRUCTION AND DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL COMPLIES WITH SECTION 4.408.1. 4.408.5 DOCUMENTATION. DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS I THROUGH 5, SECTION 4.408.3 OR SECTION 4.408.4. 4.410.1 OPERATION AND MAINTENANCE MANUAL- AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DIC, WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY WHICH INCLUDES ALL OF THE FOLLOWING SHALL BE PLACED IN THE BUILDING: 1. DIRECTIONS TO THE OWNER OR OCCUPANT THAT THE MANUAL SHALL REMAIN WITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE. 2. OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE FOLLOWING 3. EQUIPMENT AND APPLIANCE, INCLUDING WATER-SAVING DEVICES AND SYSTEMS, HVAC SYSTEMS, WATER-HEATING SYSTEMS AND OTHER MAJOR APPLIANCES AND EQUIPMENT. 4. ROOF AND YARD DRAINAGE, INCLUDING GUTTERS AND DOWNSPOUTS. 5. SPACE CONDITIONING SYSTEMS, INCLUDING CONDENSERS AND AIR FILTERS. 6. LANDSCAPE IRRIGATION SYSTEMS. 7. WATER REUSE SYSTEMS. 3.INFORMATION FROM LOCAL UTILITY, WATER AND WASTE RECOVERY PROVIDERS ON METHODS TO FURTHER REDUCE RESOURCE CONSUMPTION, INCLUDING RECYCLE PROGRAMS AND LOCATIONS. 4.PUBLIC TRANSPORTATION AND/OR CARPOOL OPTIONS AVAILABLE IN THE AREA. 5.EDUCATIONAL MATERIAL ON THE POSITIVE IMPACTS OF AN INTERIOR RELATIVE HUMIDITY BETWEEN 30-60 PERCENT AND WHAT METHODS AN OCCUPANT MAY USE TO MAINTAIN THE RELATIVE HUMIDITY LEVEL IN THAT RANGE. 4.410.1 OPERATION AND MAINTENANCE MANUAL-CONT. 6. INFORMATION ABOUT WATER-CONSERVING LANDSCAPE AND IRRIGATION DESIGN AND CONTROLLERS WHICH CONSERVE WATER 7. INSTRUCTIONS FOR MAINTAINING GUTTERS AND DOWNSPOUTS AND THE IMPORTANCE OF DIVERTING WATER AT LEAST 5 FEET AWAY FROM THE FOUNDATION. 8. INFORMATION ON REQUIRED ROUTINE MAINTENANCE MEASURES, INCLUDING, BUT NOT LIMITED TO, CAULKING, PAINTING, GRADING AROUND THE BUILDING, ETC. 9. INFORMATION ABOUT STATE SOLAR ENERGY AND INCENTIVE PROGRAMS AVAILABLE. 10. A COPY OF ALL SPECIAL INSPECTION VERIFICATIONS REQUIRED BY THE ENFORCING AGENCY OR THIS CODE. 4.504.2.2 PAINTS AND COATINGS- ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH voe LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL SUGGESTED CONTROL MEASURE. AS SHOWN IN TABLE 4.504.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE voe CONTENT LIMIT FOR COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIAL TY COATINGS CATEGORIES LISTED IN TABLE 4.504.3 SHALL BE DETERMINED BY CLASSIFYING THE COATING AS A FLAT, NON FLAT OR NON FLAT-HIGH GLOSS COATING, BASED ON ITS GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36, AND 4.3 7 OF THE 2007 CALIFORNIA AIR RESOURCES BOARD, SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING FLAT, NON FLAT OR NONFLAT-HIGH GLOSS voe LIMIT IN TABLE 4.504.3 SHALL APPLY. 4.504.2.4 VERIFICATION- VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING· 1. MANUFACTURER'S PRODUCT SPECIFICATION. 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS. 4.504.3 CARPET SYSTEMS. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING: 1. CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM. 2. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH. "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS,'' VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS SPECIFICATION 01350.) 3. NSF/ANSI 140 AT THE GOLD LEVEL. 4. SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE'" GOLD. 4.504.3.1 CARPET CUSHION.- ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE'S GREEN LABEL PROGRAM. 4.504.3.2 CARPET ADHESIVE- ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS- WHERE RESILIENT FLOORING IS INSTALLED, AT LEAST 80 PERCENT OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING: 1. voe EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCTS DATABASE. 2. PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGUARD CHILDREN & SCHOOLS PROGRAM. 3. CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM. 4. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS," VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS SPECIFICATION 01350). 4.504.5 COMPOSITE WOOD PRODUCTS- HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD (17 CCR 93120 ET SEQ.), BY OR BEFORE THE DATES SPECIFIED IN THOSE SECTIONS, AS SHOWN IN TABLE 4.504.5. 4.504.5.1 DOCUMENTATION- VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE FOLLOWING 1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. 2. CHAIN OF CUSTODY CERTIFICATIONS. 3. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD PRODUCTS REGULATION (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.). 4. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2 STANDARDS OF THE ENGINEERED WOOD ASSOCIATION. THE AUSTRALIAN ASINZS 2269 OR EUROPEAN 6363S STANDARDS. 5. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. SECTION 4.505 INTERIOR MOISTURE CONTROL 4.505.1 GENERAL. BUILDINGS SHALL MEET OR EXCEED THE PROVISION OF THE CALIFORNIA BUILDING STANDARDS CODE. 4.505.2 CONCRETE SLAB FOUNDATIONS. CONCRETE SLAB FOUNDATIONS REQUIRED TO HAVE A VAPOR RETARDER BY THE CALIFORNIA BUILDING CODE, CHAPTER 19 OR CONCRETE SLAB-ON-GROUND FLOORS REQUIRED TO HAVE A VAPOR RETARDER BY THE CALIFORNIA RESIDENTIAL CODE, CHAPTER 5, SHALL ALSO COMPLY WITH THIS SECTION. 4.505.2.1 CAPILLARY BREAK. A CAPILLARY BREAK SHALL BE INSTALLED IN COMPLIANCE WITH AT LEAST ONE OF THE FOLLOWING: 1. A 4-INCH-THICK (101.6 RNRN) BASE OF L/ZINCH (12.7 MM) OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL INFORMATION. SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. 2. OTHER EQUIVALENT METHODS APPROVED BY THE ENFORCING AGENCY. 3. A SLAB DESIGN SPECIFIED BY A LICENSED DESIGN PROFESSIONAL. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE FRAMING MEMBERS EXCEED 19-PERCENT MOISTURE CONTENT. MOISTURE CONTENT SHALL BE VERIFIED IN COMPLIANCE WITH THE FOLLOWING: 1. MOISTURE CONTENT SHALL BE DETERMINED WITH EITHER A PROBE-TYPE OR CONTACT-TYPE MOISTURE METER. EQUIVALENT MOISTURE VERIFICATION METHODS MAY BE APPROVED BY THE ENFORCING AGENCY AND SHALL SATISFY REQUIREMENTS FOUND IN SECTION 101.8 OF TH IS CODE. 2. MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET (610 MM) TO 4 FEET (1219 MM) FROM THE GRADE STAMPED END OF EACH PIECE TO BE VERIFIED 3. AT LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED ON WALL AND FLOOR FRAMING WITH DOCUMENTATION ACCEPTABLE TO THE ENFORCING AGENCY PROVIDED AT THE TIME OF APPROVAL TO ENCLOSE THE WALL AND FLOOR FRAMING. INSULATION PRODUCTS WHICH ARE VISIBLY WET OR HAVE A HIGH MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO ENCLOSURE IN WALL OR FLOOR CAVITIES. WET -APPLIED INSULATION PRODUCTS SHALL FOLLOW THE MANUFACTURERS' DRYING RECOMMENDATIONS PRIOR TO ENCLOSURE. SECTION 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 BATHROOM EXHAUST FANS. EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 2. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL 3. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF:C:; 50 PERCENT TO A MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. 4. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL (I.E., BUILT- IN). NOTES 1. FOR THE PURPOSES OF THIS SECTION, A BATHROOM IS A ROOM WHICH CONTAINS A BATHTUB, SHOWER, OR TUB/SHOWER COMBINATION. 2. LIGHTING INTEGRAL TO BATHROOM EXHAUST FANS SHALL COMPLY WITH THE CALIFORNIA ENERGY CODE. SECTION 4.507 ENVIRONMENTAL COMFORT 4.507.1 RESERVED 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. HEATING AND AIR-CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED AND HAVE THEIR EQUIPMENT SELECTED USING THE FOLLOWING METHODS: 1. THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI! ACCA 2 MANUAL J-2004 (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. 2. DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI! ACCA 1 MANUAL D-2009 (RESIDENTIAL DUCT SYSTEMS), ASH RAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI! ACCA 3 MANUAL S-2004 (RESIDENTIAL EQUIPMENT SELECTION) OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY TO ENSURE THE SYSTEMS FUNCTION ARE ACCEPTABLE. SECTION 4.503 FIREPLACES 4.503.1 GENERAL- ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED- COMBUSTION TYPE. ANY INSTALLED WOODSTOVE OR PELLET STOVE SHALL COMPLY WITH U.S. EPA PHASE II EMISSION OR PELLET STOVE SHALL COMPLY WITH U.S. EPA PHASE II EMISSION PLACES SHALL ALSO COMPLY WITH APPLICABLE LOCAL ORDINANCES. SECTION 4.504 4.504.1 POLLUTANT CONTROL - COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION, DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF WATER, DUST AND DEBRIS, WHICH MAY ENTER THE SYSTEM. 4504.2 FINISH MATERIAL POLLUTANT CONTROL- FINISH MATERIALS SHALL COMPLY WITH THIS SECTION. 4.504.2.1 ADHESIVES, SEALANTS AND CAULKS- ADHESIVES, SEALANTS AND CAULKS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS UNLESS MORE STRINGENT LOCAL OR REGIONAL AIR POLLUTION OR AIR QUALITY MANAGEMENT DISTRICT RULES APPLY 1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE OR SCAQMD RULE 1168 voe LIMITS, AS SHOWN IN TABLE 4.504.1 OR 4.504.2, AS APPLICABLE. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE 1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, ETHYLENE DICHLORIDE, METHYLENE CHLORIDE, PERCHLOROETHYLENE AND TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS, AS SPECIFIED IN SUBSECTION 2 BELOW. 2. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN 1 POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE voe STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER 00 C) C) z N (j) 0 <( u --I-""O ctl -.0 en C .::: CCI C u <C ...... Cf) C ::> 0 en '-- C & Q) <C --., ("') "SI" (j) N PROJECT STATUS NO. DESCRIPTION DATE -----'----------------------------- DATE 21112021 5:05:12 PM AGENCY# DIG JOB# SA 20182 CALGREEN NOTES G-003 I --L------,c-. ----------,_-_----------~-------------------------------"-----------------------,-,-,.----------,----------,cc.:---------------------,-,:.,-,c-, ------------,-----------,-_-----------, .. -.----,------,,,;:..-,--, -----+------,,,.°' ____ _. '"" ,,.,, > -; ',.;,,:, '-•• , ., .• , ----------------------------------------------------------------------------------------------- -:·; ' c, L C L C L C L >-w ...I ...I c:i: 55' I (E) NEIGHBORING BUILDING r (E) TREE TO REMAIN TYP. 140' -O" ' '-., / / (i-..a,.,.:.~c<"" ........ ,:.:,~·-~--;: _________ ~_:·:-..::~~-"'"'""-•~-.---=:.-~:~ .. --,-·-:--·: .... '!!"!F l ·· / -~~--=--__ ,...:. ______ ----,,f.-1~..._.,C,, ""'--=--.. ·~--,."!Ill'·:..~ -~--~---=----""'""• ~-.... --------.. ----.... ~--~:-:"'-""""'-"'--·-·-~"'..-----------------------· ,: --~~•DRAINAGE l Ii·• I • ,, ---' -_____ ·:! I ; ,o,;,,,-,·,,.-_, .,,.~,--, --~ ,-l=•"'-""_.,, ,~,, --•~,,• """"?:~ "'°'~ -~ '" "'""'°'"'''"""'""'. ,.,; ~,,wi--C•·' ·-:,J -· n-• ---',:~,·~~~-DRAINAGE ii i '--.._ • •• • }...7' -2" · ... JL. - -tl+-"--.::_~jt _ _:~ __ __,.;__:_--f,; ___ ~_,R---,-,,.,..,----: l"R----CR-; 1--R i,'-r----'-------------------_-_--, --'J'-+- -(E) LAWN DRAINAGE ---'---- 57' (E) TREE1TO REMAIN TYP.i~,,,,, / .. .. . I , L I ,-- 1 R R R_ (N) DETACHED ACCESSORY DWELLING UNIT DWELLING AREA 749 SF R .. 1 .. I R R (E) LAWN ---., :-:·M$ Ii I JI'' : I -·· --: @I ~-_v----------- __ , (E) SINGLE FAMILY DWELLING UNIT APN: 203-303-18-00 DWELLING AREA: 1,288 SF LOT SIZE: 7,006 SF -~~ DRAINAGE - _J_ ----····-i'""":·~, ----- '· .I , .: (E) LAWN DRAINAGE --~- j_ I I i I j I I I I I I ' I I ' I I 5· -o·' ~.. I It • SiDEWtK : / 10' -0" r (E)6"CURB ! : 22'. O" r-(E) PLANTING STRIP \__ · SIDEWALK 1 i (Ii,_-'-____ , __ -·----_,_ -·-·-----a.=--~==iiiiiiiC:0 --~"-iiiiiii=•-=--====-==---==---------~ ...... -oiiiii-=-------=-=i--=a.-=-iiiiiiiiiiiiiiiC=a--=-a-c'-iiiiiiiiiiiiii',a.-=--=---··---·--·.:·-··,:;,"~-----·c;·-·-iiiiiiiiiiiiii.C--ai-'-"---•c, .. , iiiiiiiiiiiiii;.-:a..----~--.. ----------------------~l;--..L 55'j: ,, / :55•· -~-. / ·, - c_L••--'"-D'_-De_' --..ii--/ ~BMP ·~ 1/8" = 1'-0" (E) NEIGHBORING DETACHED GARAGE N fEJ (E) NEIGHBORING BUILDING C L C' L C' L C I Cl"'C .. lr"\ SITE LEGEND BMPLEGEN □-----~ I CONCRETE/ IMPERVIOUS SURFACE LANDSCAPE/ PERVIOUS SURFACE SOIL DISTURBANCE AREA EXISTING DWELLING FR FR SC7~1 I I I 1MS I I I SWM SC-5 FIBER ROLLS BARRIER SC-7 STREET SWEEPING AND VACUUMING WM-1 MATERIAL DELIVERY & STORAGE AREA WM-4 SPILL PREVENTION CONTROL WM-5 SOLID WASTE MANAGEMENT AREA --------PROPERTY LINE WM-8 CONCRETE WASTE MANAGEMENT DRAINAGE --~-WATER DRAIN FLOW DIRECTION CALCULATION LOT SIZE: TOTAL DISTURBANCE AREA: EXISTING IMPERVIOUS AREA: CREATED IMPERVIOUS AREA: REPLACED IMPERVIOUS AREA: NEW TOTAL IMPERVIOUS AREA, EXISTING IMPERVIOUSNESS: NEW IMPERVIOUSNESS: IMPERVIOUS PERCENT INCREASE· 7,006 SF 749 SF 1,914 SF 354 SF 400 SF 2,268 SF 27.3% 32.3% 5% CONSTRUCTION BMP GENERAL NOTES PRIOR TO ANY SOIL DISTURBANCE. TEMPORARY SEDIMENT CONTROLS SHALL BE INSTALLED BY THE CONTRACTOR OR QUALIFIED PERSON(S) AS INDICATED BELOW: 1. ALL REQUIREMENTS OF THE CITY STORM WATER STANDARDS MUST BE INCORPORATED INTO THE DESIGN AND CONSTRUCTION OF THE PROPOSED GRADING/IMPROVEMENTS CONSISTENT WITH THE APPROVED STORM WATER POLLUTION PREVENTION PLAN (SWPPP) AND/OR WATER POLLUTION CONTROL PLAN (WPCP) FOR CONSTRUCTION LEVEL BMPS AND, IF APPLICABLE. THE STORM WATER QUALITY MANAGEMENT PLAN (SWQMP) FOR POST-CONSTRUCTION BMPS. 2. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL STORM DRAIN INLET PROTECTION. INLET PROTECTION IN THE PUBLIC RIGHT-OF-WAY MUST BE TEMPORARILY REMOVED PRIOR TO A RAIN EVENT TO ENSURE NO FLOODING OCCURS AND REINSTALLED AFTER RAIN IS OVER. 3. ALL CONSTRUCTION BMPS SHALL BE INSTALLED AND PROPERLY MAINTAINED THROUGHOUT THE DURATION OF CONSTRUCTION. 4. THE CONTRACTOR SHALL ONLY GRADE, INCLUDING CLEARING AND GRUBBING, AREAS FOR WHICH THE CONTRACTOR OR QUALIFIED CONTACT PERSON CAN PROVIDE EROSION AND SEDIMENT CONTROL MEASURES. 5. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL SUB-CONTRACTORS AND SUPPLIERS ARE AWARE OF ALL STORM WATER BMPS AND IMPLEMENT SUCH MEASURES. FAILURE TO COMPLY WITH THE APPROVED SWPPP/WPCP WILL RESULT IN THE ISSUANCE OF CORRECTION NOTICES, CITATIONS, CIVIL PENAL TIES, AND/OR STOP WORK NOTICES. 6. THE CONTRACTOR OR QUALIFIED CONTACT PERSON SHALL BE RESPONSIBLE FOR CLEANUP OF ALL SILT. DEBRIS, AND MUD ON AFFECTED AND ADJACENT STREET(S) AND WITHIN STORM DRAIN SYSTEM DUE TO CONSTRUCTION VEHICLES/EQUIPMENT AND CONSTRUCTION ACTIVITY AT THE END OF EACH WORK DAY. 7. THE CONTRACTOR SHALL PROTECT NEW AND EXISTING STORM WATER CONVEYANCE SYSTEMS FROM SEDIMENTATION. CONCRETE RINSE, OR OTHER CONSTRUCTION-RELATED DEBRIS AND DISCHARGES WITH THE APPROPRIATE BMPS THAT ARE ACCEPTABLE TO THE CITY RESIDENT ENGINEER AND AS INDICATED IN THE SWPPP/WPCP 8. THE CONTRACTOR OR QUALIFIED CONTACT PERSON SHALL CLEAR DEBRIS, SILT, AND MUD FROM ALL DITCHES AND SWALES PRIOR TO AND WITHIN 3 BUSINESS DAYS AFTER EACH RAIN EVENT OR PRIOR TO THE NEXT RAIN EVENT, WHICHEVER IS SOONER. 9. IF A NON-STORM WATER DISCHARGE LEAVES THE SITE, THE CONTRACTOR SHALL IMMEDIATELY STOP THE ACTIVITY AND REPAIR THE DAMAGES THE CONTRACTOR SHALL NOTIFY THE CITY RESIDENT ENGINEER OF THE DISCHARGE, PRIOR TO RESUMING CONSTRUCTION ACTIVITY. ANY AND ALL WASTE MATERIAL, SEDIMENT, AND DEBRIS FROM EACH NON-STORM WATER DISCHARGE SHALL BE REMOVED FROM THE STORM DRAIN CONVEYANCE SYSTEM AND PROPERLY DISPOSED OF BY THE CONTRACTOR. 10. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES. ALL NECESSARY MATERIALS SHALL BE STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID DEPLOYMENT OF CONSTRUCTION BMPS WHEN RAIN IS IMMINENT 11. THE CONTRACTOR SHALL RESTORE AND MAINTAIN ALL EROSION AND SEDIMENT CONTROL BMPS TO WORKING ORDER YEAR ROUND. 12. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES DUE TO UNFORESEEN CIRCUMSTANCES TO PREVENT NON-STORM WATER AND SEDIMENT-LADEN DISCHARGES 13. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREATE A HAZARDOUS CONDITION, 14. ALL EROSION AND SEDIMENT CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP/WPCP SHALL BE INSTALLED AND MAINTAINED. ALL EROSION AND SEDIMENT CONTROLS FOR INTERIM CONDITIONS SHALL BE PROPERLY DOCUMENTED AND INSTALLED TO THE SATISFACTION OF THE CITY RESIDENT ENGINEER. 15. AS NECESSARY, THE CITY RESIDENT ENGINEER SHALL SCHEDULE MEETINGS FOR THE PROJECT TEAM (GENERAL CONTRACTOR, QUALIFIED CONTACT PERSON, EROSION CONTROL SUBCONTRACTOR IF ANY, ENGINEER OF WORK, OWNER/DEVELOPER. AND THE CITY RESIDENT ENGINEER) TO EVALUATE THE ADEQUACY OF THE EROSION AND SEDIMENT CONTROL MEASURES AND OTHER BMPS RELATIVE TO ANTICIPATED CONSTRUCTION ACTIVITIES, 16. THE CONTRACTOR OR QUALIFIED CONTACT PERSON SHALL CONDUCT VISUAL INSPECTIONS AND MAINTAIN ALL BMPS DAILY AND AS NEEDED. VISUAL INSPECTIONS AND MAINTENANCE OF ALL BMPS SHALL BE CONDUCTED BEFORE, DURING, AND AFTER EVERY RAIN EVENT AND EVERY 24 HOURS DURING ANY PROLONGED RAIN EVENT THE CONTRACTOR SHALL MAINTAIN AND REPAIR ALL BMPS AS SOON AS POSSIBLE AS SAFETY ALLOWS. 17. CONSTRUCTION ENTRANCE AND EXIT AREA TEMPORARY CONSTRUCTION ENTRANCE AND EXITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CASQA FACT SHEET TC-10R CAL TRANS FACT SHEET TC-01 TO PREVENT TRACKING OF SEDIMENT AND OTHER POTENTIAL POLLUTANTS ONTO PAVED SURFACES AND TRAVELED WAYS. WIDTH SHALL BE 10' OR THE MINIMUM NECESSARY TO ACCOMMODATE VEHICLES AND EQUIPMENT WITHOUT BYPASSING THE ENTRANCE. (a) NON-STORM WATER DISCHARGES SHALL BE EFFECTIVELY MANAGED PER THE SAN DIEGO MUNICIPAL CODE CHAPTER 4, ARTICLE 3, DIVISION 3 "STORM WATER MANAGEMENT AND DISCHARGE CONTROL". YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIMFLAMMER a:, 0 0 z N 0) 0 <( u -.. I--0 cu -_c C en .:: ro C u <( .... Cf) C ::> 0 en ._ C & <l.J <( -, (") "SI" 0) C'l st:-D ARc1-;. «_,~ ,"o?,;EN W S 1/)', 0 C-38556 cJ) 8/3112021 /': RENEWAL -~ -f1-: DATE R-"- (:-OF CALl'<O PROJECT STATUS NO. DESCRIPTION DA lE -----···""'-·~---··--- DATE 2/1/2021 5:05:13 PM AGENCY# DIG JOB# SA 20182 BMP G-004 C L C L C L (E) NEIGHBORING BUILDING 140'0" PL / cl L I ' ' " ' ·-~"-···~ - "''"·~··•:··••'""'-'" -•-•·•·':•'·· .··-· ,'.:;: ::~:.::::.: • :[:~ •..•••. : .. · • '' • ' ' ' ., ---·-·-"" -I I 10' -O" I I C -----------1·. ---------------~ I L r ! I I b :·-, (E) FENCE . ·••· ' """""'+• . . .. -,. --· ,, ·-·I 1 .•• 9'-6" 6" I SIDEWALK ' (E) LAWN ... 15'-0" I CURB TO PROPERTY UNE ' ./ I ·· (E) TREE TO REMAIN TYP. ~; 1. l (E) 6" CURB I , I t I . J ' 22' -O" C : I (E) LAWN (E) PAVED WALKWAY _/ I ' ·•l, --~ (E) DETACHED GARAGE (E) SINGLE FAMILY DWELLING UNIT . ·• ~ I GARAGE AREA: 400 SF APN: 203-303-18-00 ~ '··•,"1 ~ /I (E) PLANTING STRIP cl L C L C' L DWELLING AREA: 1.288 SF ~ I · f' " LOT SIZE: 7,700 SF N j J .· ' ,: ' i I DEMOLISH (E) DETACHED ~ ' (E) LAWN I ~ I · : ~ GARAGE I 53' -4" 24' -1" r-c--(E) FENCE I I ~1 ~------------...i.-.--'-i---.........l~.-=c . ....,,,,_.iiiiiiiiii=iiii.=.-=iiiiiiiiiiiiiii=..=-ii=iiiiiiiiii...,,,,__,=a-=___,,,,,~"iiiiiiiiiiiii.,,,__,,,,_iiio=, . ......._,.~c.-..=-=.-=--· iiiiiiiiii __ .~-=--=aiiiiiiiiiiiii.'-""'iiiiii=iiiiiiiiiiiio=i,=--"C=-aii=,_-=---a~------.. ~ 140'0" PL / :: ~ • ' I, : ½ i (E) NEIGHBORING DETACHED GARAGE (E) NEIGHBORING BUILDING l \, \___ SIDEWALK CD EXISTING SITE PLAN 1 >-----------------------------~ 1 /8" = 1 '-0" C L C L cl L I C L C L I N f£J LEGEND ---- (E) CONSTRUCTIONS (E) NEIGHBOR BLDG. SCOPE OF WORK (E) STRUCTURE TO BE DEMOLISHED IMPERVIOUS SURFACE/ CONCRETE PERVIOUS SURFACE/ LANDSCAPE PROPERTY LINE SETBACKS 314" WATER LINE GAS LINE POWER LINE 4" SEWAGE LINE (E) 100 AMPS ELECTRICAL METER (E) GAS METER (E) 1" WATER METER (E) TREES GENERAL NOTES 1. THIS PROJECT PROPOSES NO WORK WITHIN THE PUBLIC RIGHT-OF-WAY 2. ALL DRAINAGE FROM IMPERVIOUS AREAS & DOWNSPOUTS TO BE ROUTED TO LANDSCAPE AREAS & PLANTER BOXES. YUCCA ROAD OCEANSIDE, CA 92054 760-259· 1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co C) C) z N 0) 0 <( (,_) --I-"Cl co -.0 C Cf) ,_ co C (,_) <C ...... Cf) C: ::::, 0 Cf) ,_ C ~ Q) <C -, C") "ST 0) N PROJECT STATUS NO. DESCRIPTION DATE DATE 21112021 5:04:52 PM AGENCY# DIG JOB# SA 20182 EXISTING SITE PLAN A-001 ' 0 ,, C L C L C L I c' L >-w ...I ...I <( " - -' ll. 0 0 "' ~ 7'-2" ffe ,- I I I I I I I I I 1:-·t··, '. I I ·, I , C)-,~ • • '' u; -,> _ co : iE .. r , .-r . ···, -'. : I ; I ' I I • I 28' -O" 27' -5" -------------------1 / (N) DETACHED ACCESSORY DWELLING UNIT// //// DWELLING AREA: 749 SF (E) NEIGHBORING DETACHED GARAGE -- (E) LAWN 26'-5" I •. --·1 ----------------, 2 CJ (E) FENCE 6' 14' -O" (E) COMMERCIAL BUILDING 32' -6" (E) SINGLE FAMILY DWELLING UNIT . APN: 203-303-18-00 DWELLING AREA: 1,288 SF . LOT SIZE: 7,700 SF 53' -4" (E) NEIGHBOR SINGLE FAMILY DWELLING UNIT 6' -10" 24' -1" . ·--------.... / ·;' (E) PAVED WALl<:a/VAY _/ , . (E) LAWN 24' -1" (E) FENCE ,j ----- SIDEWALK \ \_I_ I ' 10' -0" 'i ' 22' -0" :/ (E)6"CURB /1: ' : i '! ' ! ! SIDEWALK. ii i' ! ! ii ! ii (E) PLANTING STRIP CD PROPOSED SITE PLAN 1 ~__::_______::____::__ ________________________________ _ 1/8" = 1 '-0" C L C L C L C L N LEGEND ---- (E) CONSTRUCTIONS (E) NEIGHBOR BLDG. SCOPE OF WORK PROPERTY LINE SETBACKS WATER LINE GAS LINE POWER LINE SEWAGE LINE (E) WATER METER (E) 200 AMPS ELECTRICAL METER (E) GAS METER (E) TREES GENERAL NOTES 1. THIS PROJECT PROPOSES NO WORK WITHIN THE PUBLIC RIGHT-OF-WAY 2. ALL DRAINAGE FROM IMPERVIOUS AREAS & DOWNSPOUTS TO BE ROUTED TO LANDSCAPE AREAS & PLANTER BOXES. YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co c:, c:, z N en 0 <( 0 -I-"O co -.0 C <fl '1:: co C 0 <C -Cf) C ::, 0 e C ~ (I) <C -, (") s:::i-en N PROJECT STATUS , NO. DESCRIPTION DATE DATE 2/1/2021 5:04:54 PM AGENCY# DIG JOB# SA 20182 PROPOSED SITE PLAN A-002 i l b 0 , : , I --'---·-·:--· I J MASTER BEDROOM 1oisF @) CLOSET BEDROOM 114:SF 10' -1" - 28' -O" I I I ob I ...... _ • I • I I 2 A-502 LIVING ROOM 182 SF 1------------ KITCHEN 13' -3" I V--ROOF OVERHANG TYP W1 P I I --J N f/J [; (N) EAVE VENT 3.05 SF IN TOTAL 9'-0112" c::=======:::i r-------------------------------------------------------1 r---------------------------------·--.-.-------.---------7 ! I I I I I I I I I I I I I I I I I I I I I I ~ ~/ ___ ASPHALT SHINGLES, CLASS A 13' -10 112" , 350W SOLAR PANEL@ 5 UNDER SEPARATE PERMIT 0 7 EXHAUST VENT EXHAUST VENT _/ci KITCHEN VENT -r N ~ "' ' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 L ----------------------------------------: .--·-----------...J I L ______________________________________________________ J c::·=======:::i C = = =·= :J 9' -0 1/2" 1'-G"; 3D' -O" 9'-0112" ~-RIDGE VENT 9'-0112" 1' -O" N f/J LEGEND %SLOPE @) @) 0 TWH : r---7 ~ .§12. _J 1--7 L £3\<'. _J (N) WALL (N) ASPHALT SINGLES, CLASS A, REF, 7/A-301 OVERHEAD LINES WALL LINE BELOW DIRECTION OF DRAINAGE SMOKE DETECTOR (HARDWIRED) CARBON MONOXIDE ALARM (HARDWIRED) (N) DOWNSPOUTS RINNAI HIGH EFFICIENCY 5.6 GPM, 120000 BTU OUTDOOR NATURAL GAS TAN KLESS WATER HEATER, MODEL# V53DEN OR SIMILAR HVAC SUPPLY AIR DIFFUSER HVAC RETURN AIR VENT PLUMBING FIXTURE MAIN DWELLING PLUMBING FIXTURE COUNT 1. TOILETS 1 2. BATH SINK 1 3. SHOWER/TUB 1 4. KITCHEN SINK 1 5. DISHWASHER 1 6, HOSE BIB 1 ROOF VENT CALCULATION ROOF VENT CALCULATION ROOF AREA: 914 SF CLASS-I VAPOR BARRIER PROVIDED ON WINTER-WARM-SIDE: YES RIDGE VENT YES TOTAL ROOF VENT AREA REQUIRED: 914 / 300 = 3.05 SF YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co C) C) :z N 0) 0 <( (_) --I-"O ro -.D. C <f) -;:: ro C u <C -(/) C: 0 :::, <f) ,._ Q) C :::::: Q) <C -, C") s::I" 0) N PROJECT STATUS NO. I DESCRIPTION DATE I DATE 2/112021 5:04:57 PM AGENCY# DIG JOB # SA 20182 PROPOSED FLOOR PLAN A-101 4' -D" ADU SIDE SETBACK ~ I I I I I I (E) FENCE , I I I I I I I (E)FENCE ~. r ·-· I I ,- --KITCHEN VENT -PAINTED WOOD SIDING FINISH --EXHAUSTVENT 1:1" r-EXAUST VENT I -Jil"-· ..... , __ , .. ___ .. ____ ,-1 I 11 ' ' !- ' ' 3'-3" 6'-6" 1'-9" 5'-D" 10'-6" -'-oc-:...:.~.i..-----'--=-----.i---= .. .i-.---=c_::__~-------__:::__::_ _____ --:,.- ~ ADU FRONT ELEVATION ~ 1/4" = 1'-0" PAINTED WOOD SIDING FINJSH KITCHEN VENT -- I EXHAUST VENT __ EXHAUSTVENT-=:\- \ ___ i. - 4' -D" I ADU SIDE SETBACK 4-0 J . j ADV SIDE SETBAC .. K I I -I "' I (E) FENCE I I I 6 " I I I T.O. ROOF 14' -1" B.O. CEILING 8' -O" GRADE LEVEL O' -O" r T.O. ROOF 14' -1" B.O. CEILING -81 -O" ~ -t-GRA.c1E LEVEL O' -O" ~ ~ ~ RIDGE VENT / EXHAUST VENT 3' -9" 5' -O" 6' -0" 3' -0" / KITCHEN VENT -1 \ I 'l O' -3" "' T.O. ROOF I'\ 14' -1" \_J LR,DE ':.'~: ... L PAINTED WOOD SIDING FINISH PAINTED WOOD SIDING FINISH - 19' -3" RIDGE VENT 1-EXHAUST VENT 5' -O" 0 ~,~.~ 1~1,,GHT ELEVATION ---·-------------.. ____ _ 3' -9" I I I I I I I I I I T.O. ROOF 14' -1" "' h B.O. CEILING g1 -O" ' RADE LEVEL O' -0" ------·--- GENERAL NOTES EXTERIOR FINISH PAINT COLOR ON TO MATCH THE EXISTING DWELLING UNIT YUCCA ROAD OCEANSIDE. CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIMFLAMMER 00 0 z 0 N 0) 0 <!: 0 --I-"'Cl C'il -.Cl C en ,..._ C'il C 0 <C -en C ::> 0 en ,..._ C & (I) <C -, ("") ~ 0) N PROJECT STATUS NO. ; DESCRIPTION DATE DATE 2/1/2021 5:05:02 PM AGENCY# OIG JOB# SA2D182 EXTERIOR ELEVATIONS A-201 ,. " ---,-----~• ------~·~· --~~--~--~ ____ _,;rc..._· -----'----'"'-----'----''----'---~--'--~~ --~---~-----,---~'---------"'---------'--------"';.:__ _____ :__:__ _____ __c:__ _____ ____L• ___ _c__ __ _j:f,., ___ -r-__ .....,!::.ec __ __, E.N. -- A E.N. --- B u --------CEILING JOIST OR TRUSS BOTTOM CHORD TYP. ~---SIMPSON STC TRUSS CLIP \2_ CEILING MATERIAL --------2x STUD WALL ~---CEILING JOIST OR TRUSS BOTTOM CHORD TYP. ~--2x NAILER WI 16d \2_ CEILING MATERIAL -------2x_STUDWALL I SECTION VIEW .- ·.:c.'~: < ;~• ',,'" ~ >. ',. <-,:·-:> ·' J.E::::_ __ .....::::~ . ,: . . -. ~i \ WALL TYPE \ '-'· PER PLAN '• ;, ~ I INTERIOR -~ ROOF INSTALLATION PER MANUFACTURER. WIDE WELD ON BOTH SIDES ---COVER BOARD, OVER TAPERED FOAM r-------GALVANIZED ROOF NAIL WITH SEALANT ~-----CONTINUO CLEAT WITH 26 GA FLASHING WITH DRIP EDGE -PLYWOOD DECK PER STRUCTURAL, RADIANT BARRIER PER PLAN -FRAMING PER STRUCTURAL 1'4---------26 GA GALVANIZED STEEL METAL FLASHING OVER UNDERLAYMENT ~11,__ _______ JIFFY SEAL (SELF ADHESIVE SHEET ..,=,,::J MEMBRANE) ---WALL FINISH BEYOND, WHERE OCCURS lL-----------~--WOOD SIDING FINISH EXTERIOR 6 8)-~-1~-.. ~-1-~_~_A_R_I N_G_W~A_L_L _S_T_U D CONNECTION ,~~. FASCIA AT WOOD SIDING WALL I 8 i 2x CEILING JOISTS INSULATION ----. PER TITLE 24 PROVIDE BACKING@ 16"O.C. - I INTERIOR SEE RCP FOR LIGHT LOCATIONS ®f--D_1 ~-1~-.. =_P1-,;-.~-I L_I_N_G_D_E_T_A_I_L ______ ~ ASPHALT SHllnE ROOF L\\DER!J\'IMENJ' 314' roGID INru!.ATlOO t'ELFJIDHER..l:fl ROOGHQl;'! A'IIXN) MElliR,.\NE iNOOL~Tl(l;! BJ!FR.E •~• ROOF · /IJR SElt Fl:R!IIETER 9-elrilNG \'iliHEXP/tl)IN(; RADIANT BARRIER FOAM SE/!U!NT __ ..,;P..::Ec;,R ;,,:PLA,,-N .. ___J SOFAT\/EMr WOO:l S~ SIDll'f3 IJRAJl>WlE MAf llUllC!NGFJ:\!lER ltl' P',Y'/11000/ OSB SlfATHNG 1 'A!GID ltfil.JIIl[ll ---Arne l!ID..ATlON I -' ) -4--_..,,.__ ,1oOOEttSCISSOO ROOFTRUS3 EXTERIOR INTERIOR 0 ~.:~~~ A ROOF TYPE ASPHALT SHINGLES ROOFING PAPER PLYWOOD, SHEATING GRADE, RADIANT BARRIER PER PLAN INSULATION PER PLAN 518 GYPSUM WALL BOARD PER: UL 790 OR ASTM E108 /-A.PPR.OPRlATE CAULK FUJ=SM V.'/JNSUl.ArlON (B)B _ ROOF,YENTILATION DETAIL '-.______/ 3" = 1 '-0" -ROOF SHEATHING PER STRUCTURAL DRAWINGS WITH RADIANT BARRIER TRUSS PER STRUCTURAL DRAWINGS 1 --R-30 ROOF INSULATION, TYP. FURNACE EXHAUST VENT - EXHAUST VENT 5 r ROOF RIOGE VENT I I KITCHEN VENT / I R-19 INSULATION, TYP. A-304 n MASTER BEDROOM □ 107 SF \ I I I □ I □ □ \ BEDROOM 114 SF □ □□ i /. I .-!I-~~-,..._ r-,..., ,.-~~ ; ,-.,·. , --,·~ ,--+, ,..., o-•. --c":~....,---::;:-r, ,->'1"'7"'::-,~~-r~-r,;.::::c-·1::::•<~,:::::;--:-_, ;:;::.,----~-: ;_;.;;;,~,:-; ;.::.;-_,-:',l! _,r_~-::!J'v; I - "' s 00 l' _T.O. ROOF 14' -1" ' B.O. CEILING s· -011 GRADE LEVEL 01 -O" ~ ROOF SHEATHING PER STRUCTURAL DRAWINGS WITH RADIANT BARRIER 1 -R-30 ROOF INSULATION, TYP. T.O. ROOF 141 -111 TRUSS PER STRUCTURAL DRAWINGS / B.O. CEILING 81 -O" \ \ \ □ 00 R-19 INSULATION, TYP. I ! i -~ ~----,.,.,; __ : iUi ! ___ r_J:-:: I I □ ----------------GRADE LEVEL . "'· . .. --., -' .,.. -. . • _ ~rt:""': ?,S'"; 71-, 7r'.'""· 7r:,;--•_'7f"7", ;;;-., r;r,-~ ."e'.":<;; .<;;;"~7r\: _;,-,--c:-, 7~ '!'tr~?"-".'"\ :-en<;:~, tc""r<':"": 7,-s;-,, :s:,-':e 7,,--;:-; ,;::,-,~ ;;"('·. '?, --tr:_ --~_1/ __ ----------~ ~-.,_ iJl 01 -O" ~ ADU SECTION B 8 1/4" = 1'-0" ------------------------------- YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co 0 0 z N m 0 <( () -~ I--0 co -..0 C Cf) .::: co C () <C ...... Cf) C :::, 0 Cf) '- C :& (I) <C --, (Y') "ST m N PROJECT STATUS NO. DESCRIPTION DATE 1-------------- DATE 211/2021 5:05:04 PM AGENCY~ DIG JOB# SA 20182 SECTIONS AND DETAILS A-301 f, -j-----""""------------'"-------'------:::::::::::::-;2~6rGSA~G~.r1.FFl~~Sa!H~INN~GCP~A~NC,~----,----'~--------'----------------~·~·----------'-----T-----"'---------'----'------'-------~'---------'----il------,-T----~'~! ____ _;,_ ____ __:;,c._ ___ c._ ____ _j::,_ _________ ::1_ ____ -.-____ .::5.. ____ ~ " ""' 1 :2 MAX. THRESHOLD GRADIENT ffiHlM+-- -•4~-·· , -: _4,, __ :.~4->": : .. , ' ~ >., FULL WIDTH OF DOOR, SEE ISOMETRIC BELOW, SET IN B'"D OF SEA~NT. PROVIDE ISO~TOR BETWEEN TclRESHOLD AND PAN ~ ~ SLIDING GALSS DOOR PER ~------S~HEDULE "'= 1 --0\/vNER PROVIDED ', I Pi'{OVIDED RAMP ACCESSIBLE CONDITION SLOPE ----- :_ :-:.--';. ·'·:': :.--· _, -.. · .. ~ :.;" .:_--;·; ·::\:: ;:_-,'~ _.-~ 1/4" MIN. 6" ISOMETRIC VIEW, NTS. EXTERIOR FINISH PER ELEVATION ------~ MOISTURE BARRIER ------- MOLD AND MOISTURE RESISTANT 5/8" TYPE X EXTERIOR GYPSUM SHEATHING APPLIED WITH 1-3/4" GALVANIZED ROOFING NAILS 4" O.C. AT VERTICAL JOINTS. INCEASE NAIL LENGTH BY THICKNESS OF STRUC PANEL -----1:f STUD PER PLAN, MIN 16" O.C. (BATT INSULATION PER TITLE 24) STRUCTURAL PANEL PER STRUC -------- 5/8" TYPE X GYPSUM WALL BOARD APPLIED TO STUDS WITH 6D COATED NAILS @ 7" O.C. W/ END JOISTS ON NAILING MEMBERS. ------- _.----' ' ' COMPLY WITH GYPSUM ! ASSOCIATION DETAIL WP ( GA ' FILES NO. WP. 8105) I 47 STC WITH RESILIENT . CHANNELS PER NAIMA SOUND ] CONTROL FOR COMMERCIAL & RESIDENTIAL BUILDINGS I PUBLICATION FIGURE 19 ®-:-.. H-= ~-._~-.'!"-A __ L_L_F_I_R_E_R_A~TE_D_D_E_T_A_I L __ 8 MOISTURE BARRIER --------EXTERIOR FINISH PER ELEVATION _,-------FLOORING PER PLAN ll~~~~::;;,<liel1~~------4" SELF-ADHERING -->1.---2--"--~ WATERPROOF MEMBRANE <C --· .-. TO SEAL BOTTOM EDGE 0: -•• :, : ·}' OF STRUCT'L PANEL --11-ffi-i--....l ..... • < °'. .. ;._. · · (WHERE OCCURS) =-~"'-11--.;;~;;,i._.,_--.. --..r_.~> ":• ;4 '-:"". --;. <f . · ·:•: -.·· .. -m~~ --· .. . ~ COAT FACE OF CURB W/ CEMENTITIOUS SEALER -~ SLOPE EXTERIOR AWAY FROM UNIT HARDSCAPE PER ~NDSCAPE DWGS SELF ADHERING MEMBRANE; LAP UNDER AIR BARRIER SYSTEM, LAP INTO OPENING ----EXTERIOR FINISH PER ELEVATION SHIM AS REQUIRED CONTINUOUS FILLER BETWEEN GYPSUM BOARDAND FRAME, TYPICAL ..______ CORNER BEAD, TYPICAL ~--SLIDING DOOR PER SCHEDULE SLIDING GLASS DOOR HEAD 6" = 1 '-0" (,i\ DOOR HEAD 0 3" = 1 '-0" i. INTERIOR_] I ,, I ' ~ I I I 11.----EXTERIOR FINISH PER ELEVATION n.:J---MOISTURE BARRIER ---SELF-ADHERING WATERPROOF MEMBRANE SHEET METAL F~SHING -----DOOR FRAME EXTERIOR --------JAMB BEYOND ---DOOR PER SCHEDULE -----THRESHOLD SET IN MASTIC. ---ISO~TOR BETWEEN DISSIMILAR MATERIALS WHERE OCCURS 1/16"/12" ---MAT SLAB PER STRUCTURAL (A\ THRESHOLD @ GROUND LEVEL I 4 3"=1'-0" +-,-- 1 I I I WALL PER PLAN HEADER OR JAMB FRAMING PER STRUCTURAL SHIM SPACE WOOD DOOR FRAME, PAINTED WOOD DOOR STOP, PAINTED ,__ ____________ DOOR PER P~N ® l~~~~IOR WOOD DOOR JAMB (H~AD SIM.) STEP 1 HEADER WINDOW '> ROUGH-IN ~ OPENING .. ["' ,_ : :.\ :,:..=~-~ -,_-_:~-:: ~:~:; -. §L I ---- ' ,, I+ ATTACH SILL STRIP WITH TOP EDGE LEVEL WITH ROUGH SILL-EXTEND BEYOND EDGE OF ROUGH OPENING AT LEAST 8". SECURE FLASHING MATERIAL WITH GALVANIZED NAILS OR POWER-DRIVEN STAPLES. STEP 3 INSTALL WINDOW INTO ROUGH OPENING WITH SILL AND JAMB F~NGES OVER PREVIOUSLY INSTALLED FLASHING. ATTACH HEAD STEP2 -, -HEADER --·--1---"==-'---ri :,>: --- WINDOW ROUGH-IN OPENING ATTACH JAMB STRIPS WITH SIDE EDGE EVEN WITH ROUGH-JAMB FRAMING START STRIP 1" BELOW LOWER EDGE OF SILL STRIP AND EXTEND 4" ABOVE LOWER EDGE OF LINTEL. STEP4 :· .. \,{<-·\·1:\ ---C COMMENCING AT THE BOTTOM (SILL PLATE) OF THE WALL ~y BUILDING PAPER UNDER SILL STRIP. (A) FLASHING OVER THE WINDOW FLANGE. NOTE: CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND ABOVE THE INSTALL 18" WIDE STRIP OF WIRE MESH SILL F~NGE LINE ON EACH SIDE OF REINFORCING AT CORNERS OF ALL THE OPENING (SHOWN AS SHORT WINDOWS. DOORS & RE-ENTRANT DASHED LINES). CORNERS, TYPICAL. DO NOT SPLICE BUILDING PAPER HORIZONTALLY SO THAT THE PAPER WILL LAP OVER THE JAMB STRIPS. INSTALL SUCCESSIVE LINES OF BUILDING PAPER (B,C,D, ETC.) OVER JAMB AND HEAD FLANGES, LAPPING EACH COURSE. 1. LINE-WIRE WHEN USED AS BACKING TO SUPPORT BULIDLING PAPER BENEATH WIRE LATH (NETTING) FOR PORTLAND CEMENT (STUCCO), SHALL BE INSTALLED, AS FOLLOWS 2. 3. 4. WIRE GAUGE, SPACING AND ATTACHMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SPECIFICATIONS. PERIPHERAL F~SHING AT ALL EDGES OF WALL OPENINGS MUST COVER THE WIRE BACKING. NO ATTACHMENT DEVICES NOR THE WIRE BACKING SHALL COVER OR PENETRATE THE F~SHING MATERIAL . WINDOW FLASHING SHALL BE 'MOISTOP' MINIMUM 12" WIDE (UNLESS OTHERWISE DETAILED). PROVIDE SEA~NT AROUND WINDOW (VERIFY WITH WINDOW MANUFACTURER ANY CONFLICT TO BE CONFIRMED WITH ARCHITECT PRIOR TO INSTALLATION. AT WINDOW HEAD, JAMBS AND SILL, ALL FASTENERS ARE TO BE NAILED THROUGH THE WINDOW FIN NO CLOSER THAN 3 INCHES TO CORNERS, AND NO MORE THAN 10 INCHES FROM CORNERS, NAIL SHALL BE NO MORE THAN 16 INCHES ON CENTER. CD :;.~· WINDOW FLASHING WOOD ~p SIDING VENTED AIRSPACE INSULATION PER P~N PLYWOOD SHEATHING AND - FRAMING PER STRUCTURAL BUILDING PAPER --- SELF-ADHESIVE M EM BRAN E --......:fil'im,IJ-l,,:::::::--=-::7J F~SHING CONTINUOUS BEAD OF SEA~NT METAL CAP F~SHING EXPANDING FOAM SEA~NT WINDOW UNIT PER SCHEDULE, SHIM AS REQUIRED WINDOW UNIT PER SCHEDULE, SHIM AS REQUIRED 1/2" BACK DAM -~- EXPANDING FOAM SEALANT SELF-ADHESIVE F~SHING BUILDING PAPER VENTED AIRSPACE CONTINUOUS BEAD OF SEA~NT --- INSU~TION PER P~N PLYWOOD SHEATHING AND FRAMING PER STRUCTURAL ® ~~~.~?W HEAD/SILL AT WOOD SIDING YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co 0 0 z N 0:, 0 <( 0 -I--0 cu -..c, C en -;:: cu C 0 <C -Cf) C => 0 en '-Cl) C tt:: Cl) <C --, C") '<:I" 0:, N 8/31/2021 (.f)/1: RENEWAL --·--_.:§" ~J-. DATE R:-' i:" OF CALl'<O PROJECT STATUS NO. DESCRIPTION DATE DATE 2/1/2021 5:05:06 PM AGENCY# DIG JOB # SA 20182 DETAILS A-401 (,~ 2 ,,,,,-LOUVERED DOOR ___,,__ __ 2_·,c..C10'--·· __ ,..i= 4" DRYER VENT WITH BACKDRAFT DAMPER VENT TO EXTERIOR 3'. T' ~ /'---' ,,,,,-'.\ r------· ·--~--i ' 6 • ' t----\ 6' -O" 3' -8" ~ ENLARGED LAUNDRY ~ .. (0. ENLARGED KITCHEN PLAN (!_j 1/2"=1'-0" . FURNACEEXHAUSTVENT=-----_-_-_------------.:~ FORCED AIR UNIT I FURNACE - PER TITLE 24 CALCULATION R-30 ROOF INSULATION --, R-19 INSULATION --~ □ [i] 0 T.O. ROOF 14' -1" B.O. CEILING 81 -O" D 0f--E_11~-.. :-~-.~-.~-E_D_BA_T_H_R_O_O_M_S_E_C_T_I_O_N_ (N)EXHAUST FAN VENTS TO ROOF EXHAUST FAN 3" SMOOTH DUCT VENT SIZE (50 CFM MIN), TYP. 5' • 1" i T ' I 1' -1 O" - 0 ENLARGED BATHROOM 0 1/2" = 1'-0" DOOR SCHEDULE ... ]/pe Mark TYPE I WIDTH Height HEAT TRANSFER COEFFICIENT (U VALUE) SOLAR HEAT GAIN COEFFICIENT (SHGC) - D1 SF 2' -6" 7' -O" 0.6520 01 'SF 2' -611 7' -O" 0.6520 02 SF 2' -4" 7' -O" 0.6520 03 SG 6' -0" 7' -O" 0.3 0.23 D4 GD 3' -0" 6' -8" 0,3 0.23 05 1so 5' -O" 6' -8" 0.6520 05 SD 5' -0" 6' -8" D.6520 D6 !SF 2' -6" 6' -8" 06520 D6 SF 2' -6" 6' -8" 0.6520 DOOR TYPES •DIMENSIONS PER SCHEDULE I\ ' \ \ \ \ \ \ I GLAZING '\ A ' Ill '\ ,(!; VI GLAZING \ 11 I \ \ I I I G= = I /I \ 0 ' I I , f I I I // I , I I I I I , I r I I I I / I SF SG GD SD SINGLE FLUSH DOOR SLIDING GLAZED DOOR SWING GLAZED DOOR SLIDING DOOR WINDOW SCHEDULE NOMINAL NOMINAL HEAT TRANSFER COEFFICIENT (U TYPE MARK TYPE _l_s1LL HEIGHT WIDTH HEIGHT VALUE) SOLAR HEAT GAIN COEFFICIENT (SHGC) W1 W1 W1 W2 SW 3' -8" 5' -O" 4' -0" 0.3 .[sw 3' -8" 5' -O" 4' -O" 0,3 SW 3' -8" 5' -0" 4' -0" 0.3 cw 3' -8" 3' -0" 4' -0" 0.3 WINDOW TYPES •DIMENSIONS PER SCHEDULE '- '- ' " " "- / / / / / / SW cw SLIDING WINDOW CASEMENT WINDOW DOOR & WINDOW NOTES 1. FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING 2. DOOR SWING DIRECTION PER PLAN 3. DIMENSIONS DO NOT INCLUDE DOOR FRAME, U.N.O. 4. ALL HARDWARE TO MATCH FRAME COLOR UN.0. 5. PROVIDE SUITABLE ISOLATOR BETWEEN DIS-SIMILAR METALS (I.E. ALUMINUM & STEEL) 6. REFER TO SPECIFICATIONS FOR HARDWARE SETS, DOOR AND WINDOW MANUF., AND PRODUCT INFO. 7. ALL GLAZING IN DOORS SHALL BE TEMPERED 8. ALL WINDOWS (UN.O.) SHALL BE GLAZED PER TITLE 24 REQUIREMENTS. 9. ALL MANUFACTURERED WINDOWS SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONAL FENESTRATION RATING COUNCIL (NFRC) AND SHOWING COMPLIANCE WITH THE TITLE 24 ENERGY REPORT 13 ALL WINDOWS SHOULD HAVE A MAX U-FACTOR OF .36, A MAXIMUM SHGC OF .25, AND A MINIMUM VT OF .50. 14. PROVIDE TEMPERED GLASS ("TEMP") AT WINDOWS WITHIN A24-INCH ARCH OF A DOOR JAMB, AND AT GLAZING UNITS ABOVE THE SHOWER OR BATHTUB, IN SAUNAS OR STEAM ROOMS WHERE THE SILL IS WITHIN 60 INCHES MEASURED VERTICALLY FROM THE WET STANDING SURFACE 0,23 0,23 0.23 0.23 COMMENTS LOUVERED TEMPERED TEMPERED COMMENTS SNAR"' .,~.,, 1 · 0!:=;;"' Y,,-d ,, ,,,.._.,.,,.,_,,,,,c1,;,, YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU.COM WWW.SNAPADU.CO M CLIENT KIM FLAMMER 00 C, C, z N 0) 0 <( u --I--.::, Cll -_Q C CJ) -;:: Cll C u <( -en C => 0 CJ) '-- C ~ Q) <( --, ("") "SI- 0) N PROJECT STATUS NO. , DESCRIPTION DATE DATE 2/1120215:0508 PM AGENCY# DIG JOB # SA 20182 SCHEDULES AND CALLOUTS A-502 "Jc b DATA / ELECTRICITY IS e--'! PROVIDED FROM THE , (N) ELECTRICAL METER 10" Q I /~ VENT/LIGHT , COMBO I I 11" --1·.7• DATA \ I I SCONCE LIGHT ,_,,::-v-THERMOSTAT CONTROL / ,- I I I I 1-VENT/LIGHT COMBO \ 4r (GFCI ~AFCI II \ \ / ~--240V 3 PRONG PLUG FOR WASHER I DRYER I 0 f / I I 11' C, U)- 1 I \ \ ~GFCI \ ~--110V I 120V 3 PRONG PLUG FOR REFRIDGERATOR N (Df---E_11~-.~-=~-.:-~-IC_A_L_F_L_O_O_R_P_L_A_N _____ ~ f[J ------------------- POWER NOTES 1. ALL ELECTRICAL WORK SHALL BE DESIGN PER 2019 CALIFORNIA ELECTRICAL CODE, 2019 NATIONAL ELECTRICAL CODE, AND 2019 BUILDING ENERGY EFFICIENCY STANDARDS. 2. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 3. THE MAXIMUM COMBINED VOLTAGE DROP ON BOTH INSTALLED FEEDER CONDUCTORS AND BRANCH CIRCUIT CONDUCTORS TO THE FARTHEST CONNECTED LOAD OR OUTLET SHALL NOT EXCEED 5 PERCENT 4, ALL THE CONDUCTOR'S SPECIFIED IN THE PANEL SCHEDULES ARE GROUNDED SEPARATELY. 5. PURCHASE RTU WITH FACTORY INSTALLED DISCONNECT COORDINATE PROPER RATING OF DISCONNECT WITH MANUFACTURER 6. INSTALL WEATHERPROOF (WP), GFI PROTECTED, WEATHER RESISTANT RECEPTACLE OUTLETS ON THE ROOFTOP AND WITHIN 25 FT OF HEATING/AIR CONDITIONING AND IDENTIFIED AND LISTED AS "EXTRA DUTY" PER ARTICLE 406,9 (8)(1 ), 7. ALL WORK PERFORMED SHALL COMPLY WITH ALL STATE AND LOCAL ALL ELECTRICAL CODES. 8. ALL BRANCH CIRCUIT BREAKERS SHALL BE 10,000 AIC RATING, UNLESS NOTED OTHERWISE. 9. ALL THE HVAC UNITS ARE EQUIPPED WITH FACTORY INSTALLED DISCONNECT SWITCH UNLESS NOTIFIED OTHERWISE, COORDINATE WITH MANUFACTURE BEFORE INSTALLATION AND IN THE ABSENCE OF DISCONNECT SWITCH PROVIDE REQUIRED DISCONNECT AS PER NEC 430.104 AND 430.110. 10. ALL 120-VOLT, SINGLE-PHASE, 15-AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, SUNROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, AND SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS OR AREA SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN 21D.12(A)(1) THROUGH (6) 11. ALL OUTLETS IN KITCHEN AND BATHROOMS SHALL BE GFCI PER CEC 210,8 LIGHTING NOTES 1, PROVIDE LIGHTING CONTROL WITH CONTINUOUS DIMMING IN ALL AREAS. PROVIDE REQUIRED DRIVERS AND DIMMER SWITCHES FOR CONTINUOUS DIMMING USING 0-10 VOLT DIMMING. 2, LIGHTING SHALL PROVIDE NOT LESS THAN 215 LUX (20 FOOTCANDLES) AS MEASURED 30" ABOVE FLOOR. 3. ALL INSTALLED LUMINAIRES SHALL MEET THE REQUIREMENTS OF THE 2019 CALIFORNIA ENERGY CODE TABLE 150.0-A 4, BATHROOMS, GARAGE, LAUNDRY ROOMS, AND UTILITY ROOM LIGHTING TO HAVE ONE LUMINAIRE CONTROLLED BY A VACANCY OR OCCUPANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY PER GENG SECTION 150.0(K)21. IF AN OCCUPANT SENSOR IS INSTALLED, IT SHALL BE INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL REQUIRED UNDER SECTION 150.0(K)2C. 5, ALL OTHER LUMINAIRES THAT CONTAIN LIGHT SOURCES THAT MEET REFERENCE JOINT APPENDIX JAS REQUIREMENTS ARE TO BE CONTROLLED BY A VACANCY/OCCUPANCY SENSOR OR DIMMER PER CENC SECTION 150.0(K)2J. NOTE THAT CLOSETS WITH AN AREA LESS THAN 70 FT2 AND HALLWAY LIGHTING ARE EXEMPT FROM THIS REQUIREMENT. 6 SPECIFY RECESSED DOWN LIGHTING TO MEET THE FOLLOWING REQUIREMENTS PER CENC 150.0(K)1.C: A LUMINAIRES SHALL MEET THE REQUIREMENTS OF CENC TABLE 150.0A 8. BE LISTED FOR ZERO CLEARANCE INSULATION CONTACT C. AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75PASCALS D. BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING E. SHALL NOT CONTAIN SCREW BASED SOCKETS 7. IF APPLICABLE, SPECIFY THAT THE EXHAUST FANS TO BE ON A SEPARATE SWITCH FROM LIGHTS PER CENC 150.0(K)2B * SIC 08 2 -DOUBLE DOLE DISCONNECT SWITCH -PADDLE LIGHTING CONTROL SWITCH WITH DIMMER -SURFACE MOUNTED LED LIGHT FIXTURE -SURFACE MOUNTED LED LIGHT FIXTURE WITH VACANCY SENSOR HIGH EFFICACY LUMINARIES -DUPLE, RECEPTACLE 11 DV, "2' DENOTES CIRCUIT NUMBER, "GFCI" DENOTES GROUND FAULT CIRCUIT INTERRUPTER TYPE DEVICE, "WP" DENOTES WEATHER PROOF COVER, 7" A.F.F. U.N.O, THE OUTLET IS KIDS TAMPER PROOF -DUPLEX RECEPTACLE 11 OV MOUNTED 6" ABOVE COUNTER TOP OR AS INDICATED ON ARCHITECTURAL PLANS -CEILING FAN WITH VANITY LIGHT -VENTILATION FAN PROVIDING VENTILATION CAPABLE OF 50 CFM EXHAUSTED DIRECTLY TO THE OUTSIDE. EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE TO THE OUTSIDE OF BUILDING. EXHAUST FANS, NOT FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. SMOKE DETECTOR JUNCTION BOX EXTERIOR WALL LIGHT METER MAIN 0 ENCLOSED ~ BREAKER COMBINATION DEVICE PANE L-A 200A I 1P MCB '--. I 1201240V, 1PH, 3W ~ PANEL NDING TO POWER PROVIDED BY POWER PROVIDER '....._ #3CUWITHABO TERMINAL FOR LOW VOLTA GE UNITS --..._ #3 310 & 1 #6 GND IN 2" C. -, ' I ' ' I ' , ' -I --.... u G METAL WATER PIPE IF PPLICABLE A I \ I co NNECTION TO I BUI '~ LDING FOOTER STEEL IF ~------AVAILABLE, INSTALL----~ -COPPER SERVICE ELECTRICAL RISER DIAGRAM !--------·---·---------------------------- 6" = 1 '-0" -------------~ YUCCA ROAD OCEANSIDE, CA 92054 760-259-1985 INFO@SNAPADU,COM WWW.SNAPADU.COM CLIENT KIM FLAMMER co C) C) z N 0) 0 <( 0 -I-"O CCl -..c en C -;:: CCl C 0 <C -en c:: ::::, 0 Cl) '--Q) C :t::: Q) <C -, C") "SI-0) N PROJECT STATUS NO. DESCRIPTION DATE DATE 21112021 5:0509 PM AGENCY# DIG JOB# SA 20182 ELECTRICAL FLOOR PLAN E1.01 ' -