Loading...
HomeMy WebLinkAbout2533 NAVARRA DR; ; FPC2019-0266; Permit4ity of Carlsbad Print Date: 04/14/2022 Permit No: FPC2019-0266 Job Address: 2533 NAVARRA DR. CAR BAD CA 92009-7039 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial - Work Class: Fire Alarm Parcel #: 2161705401 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Project Title: Description: COSTA VERDE CONDOS -REPLACING FIRE ALARM CONTROL PANEL Applicant: FIRE WATCH TRISH LOVELESS 522 FRONT ST EL CAJON, CA 92020-4233 (619) 299-3473 Applied: 11/21/2019 Issued: 12/04/2019 Finaled Close Out: 04/14/2022 Inspector: Final Inspection: FPContractor: FIRE WATCH 522 FRONT ST EL CAJON, CA 92020-4233 (619) 299-3473 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov DF-52266:132 • A2-260 MS-4(E) PureuTeALarms Fire Alarm Control Panel by Honeywell - General The Fire'Lite MS-4 and MS-4E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to con- .. - ventional fire controls. The MS-4 is compatible with the j3TM smoke detectors from System Sensor, with drift compensation, . . maintenance alert, and freeze warning. Automatic synchroniza- tion of audio/visual devices with three selections for manufac- turer protocol. The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The MS-4 is compatible with conventional input devices such as . * two- and four-wire smoke detectors, pull stations, waterflow . . devices, tamper switches and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete list of compatible devices. Note: Unless indicated otherwise, the term "MS-4" refers to both . . . MS-4 and MS-4E models. . . Features Four Style B (Class B) Initiating Device Circuits (lDCs). Two Style Y (Class B) NACs. Optional module that converts all four lDCs and two NACs to Class A operation. 24VDC. f3TM Technology features: - Drift compensation automatically adjusts detector sensitiv- ity and increases resistance to false alarms caused by dust accumulation. - Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). - Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. - Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets, and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. - Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. - Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: - Synchronization of standard ANSI audible signals as required by NFPA 72. - Synchronization of ADA compliant strobes per NFPA 72. - Selectable for System Sensor, Wheelock, and Gentex protocols. - Selective Silence feature for manual silence of horns while strobes continue to flash on the same NAC. - Alarm verification selectable for each zone. - Disable switches provided per zone. NACs programmable for: - Silence Inhibit - Auto Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady signal - Silenceable or Nonsilenceable Silent or audible Walk Test operation mode commanded from the front keypad, with automatic return-to-normal after one hour of inactivity. Each zone may be programmed for supervisory or fire; each zone has separate red and yellow LEDs. Zone 4 is programmable for combination of tamper supervi- sory monitoring and waterflow alarm. Form-C Alarm, Trouble, and Supervisory relays. 3.0 A total usable current. 6.0 A total usable current available with optional second transformer. Control buttons: - ACK (Acknowledge) - Alarm Silence - Reset - Walk Test - Zone Enable/Disable (one per zone) LED indicators: - Fire Alarm (one per zone) - Supervisory (one per zone) - Trouble (one per zone) - Maintenance (one per zone) —AC Power - NAC Disable - Zone Disable - NAC Fault - System Trouble - Power Trouble - Walk Test - Alarm Silence - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger Fault (on circuit board) Piezo sounder for alarm, trouble, supervisory and mainte- nance. Optional plug-in 4XTMF transmitter module. Optional plug-in 4XZMF zone relay module. Optional 4XLMF transmitter module for RZA-4XF remote LED annunciator. Optional dress panel. DF-52266:B2 • 12/21/2012 - Page 1 of 2 Operation Activation of a compatible smoke detector or any normally-open fire alarm initiating device activates audible and visual signaling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay and oper- ates an optional module used to notify a remote station or initi- ate an auxiliary control function. Specifications AC POWER - TB3 MS-4: 120 VAC, 50/60 Hz, 2.3 A. MS-4E: 240 VAC, 50 Hz, 1.15 A. Wire Size: Minimum 14AWG (2.0mm2) with 600Vinsulation. BATTERY (SEALED LEAD-ACID ONLY)- J8 Maximum charging circuit: normal flat charge 27.6 VCD © 0.8 A. Maximum battery charger capacity: 18.0 AH battery (two 7.0 AH batteries can be housed in the FACP cabinet. Larger batteries require a separate battery box such as the Fire-Lite BB-17F). INITIATING DEVICE CIRCUITS - TB3 Alarm zones 1 - 4. Power-limited circuitry. Operation: all zones Style B (Class B). Normal operating voltage: nominal 20 VDC. Alarm current: 15 mA minimum. Short-circuit current: 40 mA maximum. Maximum loop resistance: 100 ohms. End-of-line resistor: 4.7K ohm, ½ watt (P/N 71252). Standby current: 4 mA. Compatible devices: refer to the Fire-Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. NOTIFICATION APPLIANCE CIRCUITS - TB2 Two NACs. Power-limited circuitry. Normal operating voltage: nominal 24 VDC. Maximum signalling current: 2.5 A total with standard trans- former 5.0 A total (2.5 A maximum per NAC) with optional transformer. End-of-line resistor: 4.7K ohm, ½ watt (P/N 71252). Compatible devices: refer to the Fire-Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. FORM-C RELAYS Trouble Relay TBS (fail-safe). Alarm Relay TB6. Supervisory relay TB7. Relay contact ratings: 2.0 A © 30 VDC (resistive). AUXILIARY OUTPUT: RESE1TABLE POWER - TB1 Operating voltage: nominal 24 VDC. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors (see notes). Power-limited circuitry. Notes: 1) Refer to the Fire-Lite Device Compatibility Document for a complete list of compatible devices. 2) Total current for nonresettable power, resettable power and two NACs must not exceed 6.0 A for the MS-4 (required optional second transformer). CABINET DIMENSIONS Door: 15.342" (38.97 cm) high x 14.667" (37.28 cm) wide x 0.375" (0.95 cm) deep. Backbox: 15.0" (38.10 cm) high x 14.5" (36.83 cm) wide x 3.0" (7.62 cm) deep. BACKBOX MOUNTING The cabinet can be surface mounted. The door is removable during installation by opening and lifting it off the hinges. The cabinet mounts using two key slots at the top of the backbox and two additional 0.25" diameter holes at the bottom. Listings and Approvals UL Listed: S624 MEA: 297-01 -E CSFM: 7165-0075:200 Ordering Information MS-4: Four-zone conventional FACP; 120 VAC, 50/60 Hz, 2.3 A. MS-4E: Same as above, but 240 VAC, 50 Hz, 1.15 A operation. CAC-4: Class A converter module. Used to convert Style B (Class B) IDC to Style D (Class A) and Style Y (Class B) NAC to Style Z (Class A). The module connects to Ji on the MS-4 cir- cuit board. 4XTMF: Transmitter module. 4XLMF: LED interface module. 4XZMF: Zone relay module, 4 form C relay. RZA:-4XF: Remote Annunciator. BB-17F: Battery box, required to house two batteries greater than 7 AH to a maximum of 18 AH. 411/411UD: Three-input (channels) model 411, and four-input model 4111LID, dual-line Digital Alarm Communicator/Transmit- ters (DACT5). Can be used as slave communicators with the FACP. DP-MS214: Optional dress panel. MS-4RB: Replacement board. TA-i -R: Optional trim ring for semi-flush mounting. A 2-zone version of this panel is also available. See OF-52211. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. • ., We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS MadeintheU.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- DF-5226632 • 12/21/2012 G gene TM ,e n RANGE SUMMARY Publication No: US-NP-RS-004 • March 2008 Enejjyt So/tio,S 1TI±TZ1TT GENERAL SPECIFICATIONS GENESISTM NPH BATTERY SERIES '. mm (lri, k2n. NPH2-12FR 12 2 68 2.68 51 2.01 88 3.46 0.84 1.85 2 A NPH3.2-12 NPH3.2-12FR 3.2 134 5.28 67 2.64 64 2.52 1.38 3.05 3 NC GENESISTM NP BATTERY SERIES .i mm )m.) mm (in.) mm (In.) kOs. (ibs) NP1-6 NP1-6FR 6 1.0 51 2.01 42 1.65 57 2.24 0.28 0.61 1 5 A NP1.2-6 NP1.2-6FR 1.2 97 3.82 25 0.98 56 2.20 0.30 0.67 1 A NP2.8-6 NP2.8-6FR 2.8 67 2.64 33 1.30 105 4.13 0.59 1.30 5 NC NP3-6 NP3-6FR 3.0 134 5.28 33 1.30 67 2.64 0.69 1.53 1 A NP3.2-6 NP3.2-6FR 3.2 66 2.60 33 1.30 104 4.09 0.59 1.30 5 A NP3.8-6 NP3,8-6FR 3.8 66 2.60 33 1.30 125 4.92 0.75 1.65 1 A NP4-6 NP4-6FR 4.0 70 2.76 47 1.85 105 4.15 0.80 1.76 5 NC NP4.5-6 NP4.5-6FR 4.5 70 2.76 47 1.85 105 4.15 0.86 1.90 5 NC NP5-6 NP5-6FR 5.0 70 2.76 47 1.85 105 4.15 0.95 2.10 5 NC NP7-6 NP7-6FR 7.0 151 5.95 33 1.30 100 3.94 1.28 2.83 1 NC NP8.5-6 NP8.5-6FR 8.5 98 3.86 56 2.20 118 4.65 1.60 3.53 9 1 NC NP10-6 NP10-6FR 10.0 151 5.95 50 1.97 101 3.98 1.99 4.38 1 NC NP12-6 NP12-6FR 12.0 151 5.95 50 1.97 101 3.98 2.04 4.48 1 - - NC NPO.8-12 NP0.8-12FR - 12 j 0.8 - 96 - 3.78 - 25 - 0.98 - 61 - 2.42 - 0.37 - 0.82 7 H/I NP1.2-12 NP1.2-12FR 1.2 97 3.82 48 1.89 56 2.20 0.57 1.25 3 A NP2-12 NP2-12FR 2.0 150 5.91 20 0.79 89 3.50 0.70 1.54 8 NP2-12-C NP2-12CFR 2.0 182 7.17 24 0.93 61 2.40 0.73 1.61 6 L NP2.3-12 NP2.3-12FR 2.3 178 7.01 35 1.38 67 2.64 1.02 2.15 1 A NP2.6-12 NP2.6-12FR 2.6 134 5.28 67 2.64 66 2.60 1.36 3.00 3 A NP2.9-12 N62.9-12FR 2.9 79 3.11 56 2.20 105 4.13 1.24 2.73 1 A/C NP3-12 NP3-12FR 3.0 132 5.20 33 1.30 105 4.13 1.18 2.60 1 NC NP3.4-12 NP3.4-12FR 3.4 134 5.28 67 2.64 67 2.64 1.39 3.06 3 NC NP4-12 NP4-12FR 4.0 90 3.54 70 2.76 107 4.21 1.70 3.74 1 NC NP4.5-12 NP4.5-12FR 4.5 90 3.54 70 2.76 107 4.21 1.76 3.88 1 NC NP5-12 NP5-12FR 5.0 90 3.54 70 2.76 107 4.21 1.81 4.00 1 NC NP7-12 NP7-12FR 7.0 151 5.95 65 2.56 100 3.94 2.59 5.72 4 NC NP12-12 NP12-12FR 12.0 151 5.95 98 3.86 100 3.94 4.06 8.95 4 C NP18-12 NP18-12FR 17.2 181 7.13 76 3.00 167 6.57 6.17 13.60 2 D/E NP24-12 NP24-12FR 24.0 166 6.54 175 6.89 125 4.92 9.07 20.00 2 C/DIE NP33-12 NP33-12FR 33.0 197 7.76 131 5.16 158+ 6.22+ 11.79 26.00 1 ElF NP35-12 NP35-12FR 35.0 198 7.80 132 5.20 170 6.69 12.61 27.80 1 F NP38-12 NP38-12FR 38.0 197 7.76 165 6.50 172 6.77 14.59 32.16 2 FIG NP55-12 NP55-12FR 56.3 229 9.02 138 5.43 207+ 8.15+ 18.01 39.70 1 M/G NP65-12 NP65-12FR 65.0 350 13.78 166 6.54 174 6.85 23.63 52.10 2 FIG NP75-12 NP75-12FR 77.5 259 10.20 169 6.65 208+ 8.19+ 26.50 58.42 1 M/G NP90-12 NP9O-12FR 90.0 304 11.97 168 6.61 229+ 9.02 31.18 68.74 M/G NP100-12 NP100-12FR 100.0 329 12.95 174 6.85 214+ 8.43+ 32.94 72.62 JIG NP120-12 NP120-12FR 120.0 407 16.02 173 6.81 235 9.25 38.41 84.68 JIG NP150-12 NP15O-12FR 150.0 483 19.02 170 6.69 241 9.49 47.13 103.90 JIG NP200-12 NP200-12FR 200.0 520 20.47 260 10.24 208 8.19 73.00 160.933 K/G nATARAFFM NPX RATTERY SERIES - • L?D j(3 mm (in.) mm (in) mm ft( kgs NPX-35-6 NPX-35-6FR 6 35W/Cell 8 151 5.95 33 1.30 100 3.94 1.43 3.15 1 NC NPX-50 NPX-50FR 50W/Cell 13 151 5.95 50 1.97 - 100 - 3.94 - 2.09 - 4.60 - 1 - - NC NPX-25 NPX-25FR 12 23W/Cell 5 - 90 - 3.54 - 70 2.75 107 4.21 1.95 4.30 1 NC NPX-35 NPX-35FR 35W/Cell 8 151 5.95 65 2.56 100 3.94 2.75 6.06 4 NC NPX-80 NPX-807 80W/Cell 20 181 7.13 76 2.39 167 6.57 6.35 14.00 2 D/E NPX-100 NPX-100FR 95W/Cell 28 166 6.54 125 4.92 175 6.89 9.70 21.38 2 D/E NPX-135 NPX-135FR 135W/Cell 33 197 7.76 131 5.16 158+ 6.22 11.94 26.32 1 E/F NPX-150 NPX-150FR 150W/Cell 40 197 7.76 165 6.50 172 6.77 14.29 31.50 2 FIG FOOTNOTES: * FR: UL94-VO, Flame Retardant Case and Cover (Oxygen index 28) + Height is top cover. Overall Height, including terminal is dependent on the terminal configuration Recognized by UL File No. MH16464 NOTE: All dimensions are +/- 0.08 inches (2mm); Weights are +1- 5% Torque Specifications: MS bolt: 26.6 lbf.in (3Nm) +1- 5% M6 bolt: 44.31 lbf.in )5Nm) +1-5% M5 receptacle: 35.4 lbf.in )4Nm) +1-5% M6 receptacle: 65 lbf.in )6.8Nm) +1- 5% 2 www.enersys.cOm Publication No: US-NP-RS-004 • March 2008 JJJJ J} gec2 NP I AVflhIT III IISTRATIflN L TI I LI L__ 2 L 3 ejie i L 4 i L i e j 6 I 7 8 ___L TflMIIJAI III IISTRATIflN A INCH MM 1r B I C aMM c ''°,7 INCH = MM 0.313 7.95 D NCH AM 0.472 11.99 0.250 8.35 0.472 11.99 0.197 4.75 0.250 6.35 ,_.. 0.250 6.35 fl 0.453 11.51 0004 010 0.004 010 M5 L LF 7 18-01 0551 14,00 0. .:: M6 0. 310 7.87 ! ': 18 0.420 10.67 160 4.06 Ll INCH MM 0.860 21.84 0.530 13.46 10.92 11,1115 7.49 KEA r FC37q J °°' 0 0.430 INCH = MM 1.524 26.51 .910 23.11 0~336 8~51 K INCH = MM 0.910 23.11 at go 9 0.39 1.100 27.94 4 L INCH MM 0.870 22.01 0.050 13.97 1::: 0.230 5.84 ________- LTi LM 0,630 INCH - Note: 0.806 20.47 E@ =rIr4iri I D.69D 0.760 0.690 0.630 19.30 17.53 16.00 Dimensions are in inches (mm) Tolerances are ± 0.02 in. for dimensions < 5mm 1 0.394 10.01 ± 0.04 in. for dimensions ~: 5mm • 0.335 8.50 ± 0.08 in. for all height dimensions unless otherwise specified. Charging Standby use: Apply constant voltage charging at 2.275 volts per cell (or 2.25-2.30VPC). Cyclic use: Apply constant voltage charging at 2.40-2.50 VPC. Initial charging current should be set at less than 0.25CA. Top charge: Product in storage (ambient temperature 25°C/77°F) requires a top charge every six months. Apply constant voltage at 2.40 volts per cell, initial charging current should be set at less than 0.1 CA for 150020 hours. Discharge Stop operation when voltage has reached the minimum permissible voltage. Recharge immediately. Do not operate at 6CA or more current continuously. Storage Always store battery in a fully charged condition. If battery is to be stored for a long period, apply a recovery top-charge every 6 months. Store batteries in a dry and cool location. Temperature Keep within ambient temperatures of -15°C to +50°C for both charging and discharging. Incorporating battery into equipment Encase battery in a well ventilated compartment. Avoid installing battery near heated units such as a transformer. House the battery in the lowest section of the equipment enclosure or rack to prevent unnecessary battery temperature rise. Others Avoid terminal short circuit. DO NOT expose to open flame. Avoid setting batteries in environments which can cause direct contact to gasoline, paint thinner, organic solvents, synthetic resins, oil, etc. 3 www.enersys.com Publication No: US-NP-RS-004 9 March 2008 UI.. I Temperature TESTING CONDITIONS: DISCHARGE CURRENT: 0.1 7C Mop. (F.V 1.7V/CELL) CHARGING CURRENT: 0.09C Mop. CHARGING VOLUME: 125% OF DISCHARGED CAPACITY AMBIENT TEMPERATURE: 20 C (NTF TO 77F) lb AR 80 0 Ul 200 000 600 600 000 1200 1400 Number of Cycles t) B ICA - 6.900 hOly. 0.001 CONSTANT VOLTAGE 4009101148 15)0(61 (V) ATWClIt,l 20 100 700 0LTAGE M' IN to 0A I Charging Time (Hours) TESTING coNomorAs: FLOATING VOLTAGE: 2.25 TO 2.30V/CELL AMBIENT TEMPERATURE: 20CC TO 22C (60Ti TO 72F) (614%) 120 100 20 We (Veco) 1 ------- bçicTERsjcS 1 1: 0I0 f0)T1fl. 00. 11.1 hil • iuiiiIi • III.IRI1IIIlIII ___ uuiiau•uuiuu I Distributed by: Encr EnerSys EnerSys Europe I P.O. Box 14145 Zurich, Switzerland I I Reading, PA 19612-4145 Tel: +41(0)44215 74 10 I I USA Tel: +1-610-208-1991 EnerSys Asia © 2008 EnerSys. All rights reserved. I I +1-800-538-3627 Guangdong, China Trademarks and logos are the property Tel: +86 755 2689 3639 of EnerSys and its affiliates unless otherwise noted. www.enersys.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0200 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Model MS-2 and MS-4 fire alarm control units. Model MS-2 suitable for local, central station and proprietary (protected premises). Model MS-4 suitable for non-coded; local, remote station, auxiliary, proprietary (protected premises) and central station (protected premises) when used with appropriate option modules and additional separate listed equipment; automatic, manual, waterflow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-2, -4 Control Unit 411, 411UD, 4IIUDAC DACT 4XTMF Transmission Module CAC-4 Converter Module RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control panel for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division