Loading...
HomeMy WebLinkAbout5780 FLEET ST; 200; FPC2022-0007; PermitI-:i 415N III I MIN 4,261 Mao Print Date: 04/14/2022 Permit No: FPC2022-0007 Job Address: 5780 FLEET ST, # 200, CARLSBAD, CA 92008-4714 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel 4*: 2111001300 Track #: Applied: 01/11/2022 Valuation: $272,000.00 Lot 4*: Issued: Occupancy Group: Project 4*: Finaled Close Out: 04/14/2022 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check 4*: Final Inspection: Project Title: Description: NORTHWESTERN MUTUAL -SPRINKLER TI (30 HEADS) Applicant: FPContractor: BRAD WRIGHT SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD 4760 MURPHY CANYON RD SAN DIEGO, CA 92123-4321-SAN DIEGO SAN DIEGO, CA 92123-4321 (858) 279-6122 (858) 279-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $607.00 Total Fees: $607.00 Total Payments To Date: $607.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov ?I', M-7. NORTHWESTERN MUTUAL MATERIAL SUBMITTAL 5780 FLEET STREET CARLSBAD, CA 2008 1-10-22 SPRINKLERS orldwide I tqC00 Contacts www.tyco-fure.com W Series TY.FRB - 2.8, 4.2, 56, and 80 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall ks operate In if he sftutkri or cauas it to operate prematurely. Page 1 of 12 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet 1FP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. NOTICE The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. DECEMBER 2020 Sprinkler Identification Number (SIN) TY1131 . . . Upright 2.8K, 1/2 in. NPT 1Y1231.. Pendent 2.8K, 1/2 in. NPT TY2131 . . . Upright 4.2K, 1/2 in. NPT TY2231.. Pendent 4.2K, 1/2 in. NPT TY3131. . Upright 5.6K. 1/2 in. NPT ITY3231.. Pendent 5.6K, 1/2 in. NPT I TY4131 . . . Upright 8.0K, 3/4 in. NPT TY4231.. Pendent 8.0K, 3/4 in. NPT TY4831 . . . Upright 8.0K, 1/2 in. NPT TY4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved See Tables A, B, C and D for complete approval information including corrosion- resistant status. Maximum Working Pressure See Table E TFPI7I T(52 1/4" mm) 1-9/16 (39,7 mm) STYLE 10 or 20 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. -.- RECESSED PENDENT CROSS SECTION 7 1 STYLE 10 or 20 H— 2-7/8° (73,0 mm) DIA. - RECESSED PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION 6° nm) TFPI7I Page 2 of 12 * Temperature rating -'-' Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector, special request. PLATE SEATING SURFACE 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing 7/16° (111 , mm) NOMINAL r MAKE-IN 2-3/16° 1/2° NPT** t WRENCH FLATS UPRIGHT PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT ('TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT * Temperature rating -- Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7/16° 1,11 mm) NOMINAL MAKE-IN I 2-3/16' (55,6 mm) 1/ 1/2" NPT WRENCH FLATS UPRIGHT FIGURE 2 QUICK RESPONSE SERIES TYFRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient K=2.8 GPM/p5i½ (40,3 LPM/bar½) K=4.2 GPM/p5i½ (60,5 LPM/bar1h) K=5.6 GPM/psi½ (80,6 LPM/bar"4) K=8.0 GPM/psi (115,2 LPM/bar'h) Temperature Rating See Tables Aand B Finishes Sprinkler: See Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb ...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel* Bulb...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON *Type L316 stainless steel (UNS 31603) per ASTM A479/479M or BS EN 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. * Temperature rating is indicated on Deflector. Pipe thread connections per ISO 7-1 can be provided on special request. 1/2° NPT UPRIGHT 7/16° 1,1 mm) OMINAL lAKE-IN I 2-3/16° (55,6 mm) UPRIGHT PENDENT STYLE 10 RECESSED ESCUTCHEON 2-3/16° (55,6 mm) (38,1 mm) 2-7/8° (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY TFPI7I Page 3 of 12 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ESCUTCHEON PLATE SEATING SURFACE 7/16° :11,11 mm) 'IOMINAL T(55,6 MAKE-IN mm) 2-3/16 ( (55,15 mm) t WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON CROSS SECTION 2-7/8° (73,0 mm) DIA. RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2° ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. FIGURE 3 ______ QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT rTY3231)ISPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N•m). Higher 111101111 at t1t1ue on dItot the iplhkli- inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Fi ure 1 to Figure 5, apply the W-1qe pHrikle Wenoh tti the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, see Figure 15. With reference to Figure 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mowritipg rJPtP intI !to flange cornea in contact *lth the ce I ng. 2-7/8" (73,0 mm) DIA. - RECESSED PENDENT CROSS SECTION RECESSED PENDENT CROSS SECTION / W. 2-7/8" (73,0 mm) DIA. TFPI7I Page 4 of 12 * Temperature rating -- Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 1/2 (12,7 mm) NOMINAL F1 7—r-- 6 " MAKE-IN 5/1 2-1'/4"1-9/16 I (57,2 mm) (58,7 mm) 3/4U NPT t WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON ALL FINISHES EXCEPT POLY-STAINLESS UPRIGHT WRENCH 3/40 ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated 1/2" NOMINAL (12,7 mm) _________ SURFACE 4 - Bulb 6 - Deflector* on Deflector. - MAKE-IN (58,7 mm) 1-9/16" I (57,2 mm) STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TYFRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw i 3 - Sealing 6 - Deflector * Assembly 4 - Bulb 2-1/4" _______ (57,2 mm) (39,7 mm) IY6* * Temperature rating is 1-9/16" indicated on Deflector. 5 Pipe thread connections Iprovided per ISO 7-1 can be on special request. CROSS SECTION Ll 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" 1/2 NPT t WRENCH FLATS UPRIGHT PENDENT FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFPI7I Page 5 of 12 2-7/8 DIA. (73,0 mm) 3/4" (19,1 mm) I 2-1/4 DIA. 1/4"(6,4mm) (57,2 mm) MOUNTING PLATE ~ /a 1/8" (3,2 mm) f 1-5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4° DIA. 1/4° (6,4 mm) / FACE OF (57 ' 2 mm) MOUNTING SPRINKLER / PLATE FITTING 1/8° ra~ (3,2 mm) MOUNTI SURFAC E/SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 3/4"(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 2-7/8 DIA. I.' (73,0 mm) 1/2±1/8" 1/2"(12,7mm) (12,7±3,2 mm) 2-1/4 DIA. I 1/4(6,4 mm) / FACE OF [_(572 mm) l MOUNTING SPRINKLER PLATE FITTING 1/8 (3,2 mm) P77 MOUNTING t _ SURFACE CLOSURE SERIES 1-5/16° (33,3 mm) - TY-FRB 1-1/16° (27,0 mm) FIGURE 7 SERIES TYFRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. (73,0 mm) 1/2±1/8" 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4° DIA. 1/4(6,4 mm) I / FACE OF [572 mm)1 MOUNTING SPRINKLER PLATE I FITTING 1/8" (3,2 mm) P72??. I MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) - CLOSURE TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 5/8±1/4° (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-FRB TFPI7I Page 6 of 12 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER f PLATE FITTING 1/8" (3,2 mm) \4 MOUNTING t j SURFACE CLOSURE SERIES 1-1/4' (31,8 mm)J TYFRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA 1/4" (6,4 mm) /(57,2 mm) -H FACE OF I MOUNTING SPRINKLER L _ PLATE FITTING 1/8" I I (3,2 mm) MOUNTING / SURFAC5// . CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13/16' (20,6 mm) FIGURE 12 SERIES TYFRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4" NPT MODELS) FIGURE 14 W-tYN I WRENCH 2-7/8" DIA. p.' (73,0 mm) 1/2±1/8" 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I / FACE OF [(572 mm)1 MOUNTING SPRINKLER PLATE I FITTING 1/8' / / (3,2 mm) __ p777> I $- K_ MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) - CLOSURE TYFRB 1" (25,4 mm) FIGURE 11 SERIES TY.FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) I (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE I FITTING I 1/8" (3,2 mm) \4 MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) - TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-tPNN p HflHIN$ SPRINKLER WRENCH TFPI7I Page 7 of 12 Sprinkler Finish5 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated I Polyester 135°F (57°C) Orange 155°F(68°C) Red Pendent (TY1231) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1,2,3,4 135°F (57°C) Orange 155-F (68-C) Red Upright (TY113I) 175°F (79°C) Yellow 2.8 200°F (93°C) Green 1/2 in. NPT 286-F (141-C) Blue 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY1231)a Figure 6 175°F (79°C) Yellow 200°F(93°C) Green 1,2,4 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY1231)b Figure 7 175°F (79°C) Yellow 200°F (93°C) Green NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFPI7I Page 8 of 12 Sprinkler Finish3 K-Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyester 135°F (57°C) Orange 155-F (68-C) Red Pendent 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Upright (TY2131) 175°F (79°C) Yellow 4.2 1/2 in. NPT 200°F (93°C) Green 2 286°F (141°C) Blue 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (rY2231)a Figure 8 175°F (79°C) Yellow 200°F(93°C) Green 135°F (57°C) Orange Recessed Pendent 155°F (68°C) Red (TY2231)b Figure 9 175°F (79°C) Yellow 200°F(93°C) Green NOTES Installed with Style 10(1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C*Frame and Deflector only. Listed by Underwriters Laboratories, Inc.,(UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFPI7I Page 9 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb I1iciuud Brass Chrome Polyesterc Plated C Lead PoIyStainlessC oated 135°F (57°C) Orange 155°F(68°C) Red Pendent 1, 2, 3, 4, 5, 6,7 1,2 1,2,3,5 175-F (79-q Yellow 200°F (93°C) Green 286-F (141-q Blue 135°F (57°C) Orange 155-F (68-q Red Upright (T331) 1, 2, 3, 5,6 1,2 1,2,3,5 175-F (79-q Yellow 200-F (93-q Green 17?n Blue 286-F (141-q NPT 135-F (57-q Orange 155°F (68°C) Red Recessed Pendent 1,2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green Figure 10 286-F (141-q Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)b 1, 2, 3, 4, 5 N/A N/A - 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286-F (141-q Blue NOTES Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. N"3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C*Frame and Deflector only. d. Not available (N/A). Listed by underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by underwriters Laboratories, Inc., for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Lose Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Lose Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFPI7I Page 10 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Brass I Chrome Plated Polyesterc PolyStainlessc Lead Coated 135°F (57°C) Orange 155°F (68°C) Red Pendent (TY4231) 175°F (79°C) Yellow 200°F(93°C) Green 286°F (141°C) Blue 1, 2, 3,4, 5, 6, 7 1,2 1,2,5 135°F (57°C) Orange 155°F (68°C) Red Upright (TY4131) 175°F (79°C) Yellow 200°F(93°C) Green 8.0 in. 3/4 Blue 286°F (141°C) NPT 135-F (57-C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)a 1, 2,5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green Figure 12 286-F (141-C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)b 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 13 286-F (141-C) Blue 135°F (57°C) Orange 155-F (68-C) Red Pendent (TY4931) 175°F (79°C) Yellow 200°F (93°C) Green 8.0 1/2 in. NPT 1, 2, 4, 5,6 N/A 1,2,5 286°F (141°C) Blue 135-F (57-C) Orange 155°F (68°C) Red Upright (TY4831) 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue NOTES Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C'Frame and Deflector only. d. Not available (N/A). Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLED LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 11 of 12 Sprinkler Finish K-Factor Type Natural I Chrome Polyester Lead Coated Brass Plated Pendent (TY1231) and 2.8 Upright (TYII31) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A Recessed NPT Pendent (TY2231) Pendent (TY3231) and 5.6 1/2 in. Upright (TY3131) 250 psi (17,2 bar) NPT or 175 psi (12,1 bar)' Recessed Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (1Y4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (rY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use In Canada (C-UL); and, the Approval by the City of New York. Not available (N/A). TABLE E MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Tha t at have beeM ex6eed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more information, see Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, 011 rn$It1tIhsd by n 11.111111411 IhøMu- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more informa- tion, see Installation section. Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resis- tant material of construction. There- after, annual inspections per NFPA 25 should suffice. Inspections of corro- sion-resistant sprinklers are recom- mended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long- term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 POLYESTER PURE WHITE - POLYESTER (RAL9010)2 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK - POLYESTER (RAL9005)3 7 LEAD COATED 9 I CHROME PLATED TFPI7I Page 12 of 12 P/N 57— XXX— X— )(XX I I SIN SPRINKLER 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) 1Y2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) 1Y4231 360 8.0K UPRIGHT (1/2 in. NPT) TY4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 TEMPERATURE RATINGS I 135 155 I 155-F (68-C) 175 I 175-F (79-C) 200 I 200°F(93°C) 286 I 286°F(141°C) NOTES Available only on TY3131, TV3231, 1Y4131, and TY4231 Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLE F SERIES TY.FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Ponnbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02020 Johns,,,, Control.. NI right. reserved. All specifications and other Intomnetlen shown were current as of document revision date and are subject to change without notice. Johnson 400 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA ore vefloteved frodon,ndvn of N000nd Fire Protection A000dofioc; Controls TEFLON Is rogistomed Eodnmutkof DuPont PIPE I —1 J cr 0 CT 1LTh1 —.w 13 0 Cj (n . 0 qcb ' 0 13 (I, IkVAIJA ID ull Moose Tube® is a customer focused, D growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. VA' www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 ( c®us LISTED APPROVED [40 NFM -==- BULL MOOSE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED APPROVED Gol NFN ADVANTAGES OF BULL MOoSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masur Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MlC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard It®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and witsout incurring obligation. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube's made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED <z> APPROVED C;] NF == 2.1 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 11/4 1660r 11.442 j 1.81 lbs/ft 11 - 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 [ 627 264 lbs/ft ( 4.223 - 37 2-1/2 875 _2 2.635 492 3.53 lbs/ft 5.893 30 3 T 3.500 - 3.260 ][ 154 [ 434 lbs/ffl 7.957 -.- -- ii 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS --a-. NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) - CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1380 'r 1.00 1.68 lbs/ft 2.055 70 11/4 1660 100 227IbsIft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2067_100 ik 3661bs/ft 5114 30 21/2* 2.875 2.468 -- 1.00 5.80 lbs/ft 7.875 30 3* 3500 3.068 1 100 L 7581bs/f' 10783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest Ut Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas TX Masur OH BULLIVIDOSE TUBE cotv,pAI%jv 63017 SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm lbs/ft. kg/rn CRR Lift 1¼ 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1'/a 1.500 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21/2 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.600114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CRR formula, UL Fire Protection Dlrecto,y, Category VIZY. The CRR Is a ratio value used to measure the ability eta pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES Ii,. mm In. mm - In. mm I Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1¼ 11 1.650 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CPR Is a ratio value used to measure the ability eta pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C@ <~> APPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and tJL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinklerpipe up to 6' receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: ENGINEER: LOCATIONS: fl BLACK 700 South Dock Street Sharon, PA 16146 P 800.257.8182 F 724.346.7260 CONTRACTOR: DATE: SPECIFICATION REFERENCE: SYSTEM TYPE: COMMENTS: O HOT-DIP GALVANIZED WFS-O51516 info@wheatland.com wheatland.com fVft4mt1andTube Follow us on Twitter: A DIVISION OF ZEKELMAN INDUSTRIES (8WheatlandTube FITTINGS TED APPROVED pproval Details and UmitaSons, abaSe at w.anv1lIntLcom or AiMP Sates Re pre sentative. FIG. 3201 900 Elbow FIGURE 3}101 900 ELBOW Nominal Size Maximum Working PressureA Dimension A - Approx. WI. Each In. (mm) PSI (kPo) in. (mm) 1bN. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11/4 500 1.75 0.90 32 3450 44.45 0.41 11/2 500 1.94 1.20 40 3450 49.216 0.54 2 500 2.25 1.85 50 3450 51.15 0.84 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME Bi 6.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. 1I!Ill lINFORMATI ON A1 1ul'I.iSTAMP Project: Approved Address:[-]Approved as noted Contractor: J Not approved Engineer: Remarks: lUIIlUNl Poll: Notes 1: Notes 2: SPF/Dl-1.15 iTUl APPROVED Approval Data and Umftalions, abaSe at www.anvllinil.com or 1 Anvil* Sales Representative. FIG. 3201R Reducing 900 Elbow HB- + 10 1 x 2 2 FIGURE 3201R 1REDUCING 90 ELBOW Nominal Size Max. Working PressureA Dimensions Approx. WI. Each 1 x 2 A B In. (mm) PSI kPa) In. (mm) In. (mm) tbs. (kg) 1 x ½ 500 1.26 1.36 0.44 25x 15 3450 32.00 34.54 0.20 1 x V4 500 1.37 1.45 0.52 25x20 3450 34.79 36.83 0.24 11/4 x ½ 500 1.34 1.53 0.64 32x 15 1 34550 34.03 38.86 0.29 1¼ x V4 500 1.45 1.62 0.72 32x20 3450 36.83 41.14 0.33 1¼ x 1 500 1.58 1.67 0.75 32x25 3450 40.13 42.41 0.34 1½ X 500 1.65 1.80 0.92 40x25 1 3450 41.91 45.72 0.42 1½ x 1¼ 500 1.82 1.88 1.08 40x32 3450 46.22 47.75 0.49 2x½ 500 1.49 1.88 1.08 50x15 3450 37.84 47.75 0.49 2 x V4 500 1.60 1.97 1.24 50x20 1 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50x25 3450 43.94 51.30 0.64 2 x 11/4 500 1.90 2.10 1.52 50x32 3450 48.26 53.34 0.70 2x 11/2 500 2.02 2.16 1.65 50x40 1 3450 1 51.30 54.86 0.75 Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B 1 .20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest ULJULC, and FM pressure ratings versus pipe schedule, please visit anvilinil.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project: ]Approved Address: E] Approved as noted Contractor: J Not approved Engineer: Remarks: l$l1Il Ø: Notes 1: Notes 2: SPF/Dl-1.15 Victaulic® FireLockTM Outlet-I 4tauiicr Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 -21/2"/DN32--DN65 Threaded Outlet Sizes: ½"/DN15, 3/4°/DN2O, and 1"/DN25 NOTE IGS Grooved 1/DN25 Outlets available for this product. See publication 10.54. Maximum Working Pressure 300 psi/2068 kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS c@u <R> rVdjS OLKB LOM LPS iiee tseee 3.1 Cert1LPCB Ref. 4918127 NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. victaulic.Com 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. 1 4 irctaullicr victaulic.com I 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) E Orange coating. E Red coating (standard for EMEA-I and Asia Pacific). LI Optional: Contact Victaulic with your requirements for other coatings. Gasket': LI Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: LI Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type Ill (imperial) or Type II (metric). S S 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 A_CtaU1iC:r victaulic.com 4.0 DIMENSIONS I Style 922 'I IFj IUI ,4pUI I_I Style 922 Size Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T V W V Z (Each) inches inches inches inches inches inches inches inches lb ON mm mm mm mm mm mm mm kg 11/4 1/2 1.660 0.840 - 130 1.83 1.10 3.87 2.56 1 DN32 X DN15 42.4 X 21.3 2 %xl~ 33 1 47 28 98 65 0.5 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 DN2O i 26.9 2 ~ X 1 3A 33 47 28 98 65 0.5 1 ¶ 1.315 1.52 2.18 1.10 3.87 236 1 DN25_ 2 ~x1~ 39 55 28 98 65 0.5 11/2 1/2 1.900 0.840 1.42 1.95 1.22 4.08 256 1 40 DN15 48.3 21.3 2 %xl~ 36 50 31 104 65 0.5 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 DN20 26.9 2 %xl% 36 50 31 104 65 0.5 1.64 230 1.22 4.08 256 1 1 1.315 DN25 2 %xl~ 42 58 31 104 65 0.6 2 1/2 2.375 0.840 166 2.19 1.46 4.60 2.56 1 50 DN15 60.3 21.3 2 ~X 1% 42 56 37 117 65 0.6 1.64 2.19 1.46 4.60 256 1 3/4 1.050 DN20 26.9 2 ~ x 1 ~ 42 56 37 117 65 0.6 1.88 254 1.46 4.60 256 2 1 1.315 DN25 33.7 2 %x 13A 48 65 37 117 65 0.7 21/2 1/2 2.875 0.840 1.91 2.44 1.71 5.40 256 2 DN15 73.0 213 2 ~x1~ 49 62 43 137 65 0.7 1.89 2.44 1.71 5.40 256 2 3/4 1.050 DN20 26.9 2 ~x 1~ 48 62 43 137 65 0.7 2.13 2.79 1.71 5.40 236 2 1 1.315 DN25 2 ~x1~ 54 71 43 137 65 0.7 DN65 1/2 3.000 0.840 1.91 2.44 1.71 550 2.56 2 DN15 76.1 213 2 ~x 1~ - 49 62 1 43 140 65 0.7 1.89 2.44 1.71 5.50 256 2 3/4 1.050 DN20 26.9 2 3A x 1 ~ 48 62 43 140 65 0.7 2.13 2.79 1.71 550 256 2 1 1.315 DN25 2 ~x1~ 54 71 43 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 (tauIicr victaulic.com I 5.0 PERFORMANCE I Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 11/4 1 8.5 12.5 DN32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DNSO DN25 2.6 3.8 21/2 1 8.5 12.5 DN25 2.6 3.8 1 8.5 12.5 DN65 DN25 2.6 3.8 Hazen-Williams coefficient of friction is 120. 1 FireLockTm Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING QO • Read andunderstand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes 1 A6 30 1 ¼ 2 32 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 ,J1tIuIic victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 1¼x½ 300 300 300 232 232 232 DN32XDN15 2068 1 2068 2068 1600 1600 1600 1 1/4x3/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1¼x1 300 300 300 232 232 232 DN32XDN25 2068 2068 2068 1600 1600 1600 1½x½ 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1 ½x3A 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1½x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2x½ 300 300 300 232 232 232 DN50XDN15 2068 2068 2068 1600 1600 1600 2x% 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1 300 300 300 232 232 232 DN50XDN25 2068 2068 2068 1600 1600 1600 2½x½ 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x3A 300 - 300 300 232 232 232 2068 2068 2068 1600 1600 1600 21/2 x 1 300 300 300 232 232 232 2068 2068 2068 1600 , 1600 1600 300 232 232 232 DN65XDN15 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 300 232 232 232 0N65 X DN25 - - 2068 1 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide 29.01: Victaulic Terms and Conditions of Sale 1-100: Installation Instructions -922: Installation Instructions FireLockTM Outlet-T User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on WeChat. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 N/ HANGERS Fig. 25- Surge Restrainer c®t USTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line B3170N9 Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing (B-Line B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line B317ONFC) Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe ®TOLCO Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe ./ types and protect CPVC plastic pipe from abrasion. Captured design ,.- keeps adjusting nut from separating with hanger. Hanger is easily - -. installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in B hanger before installation. Adjusting nut is easily removed. / Approvals: Underwriters Laboratories listed 0/2" (15mm) thru 8" (200mm)) A in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 - - and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Ag. 200.1/2 to 200-2 FIg. 200-2/2 to 200-8 Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts r -I in place a knurl nut. :of Part number and pipe size I Order -- Note: For metric hanger rod sizes add the metric rod size to the figure number. Example: 200M8-11/2 or 200M10-11/2 Fig. 200 Fig. 200C Fig. 200F PartTlF'. 200-/2 ' Pipe Size Ii Ii. 1/11 (15) Rod /8"-16 ' Size M8 or M10 ' A i. 31/8° ' (79.4) 2I8" B (66.7) Max. Rec. 14.. 400 ' Load (1.78) Approx. )!/1Wi I ii i (5.0) 200-/4 /8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 400 (1.78) 11 (5.0) 200-1 ._ 1° (25) /8"-16 M8 or M10 3/8" (85.7) 2/8" (66.7) 400 (1.78) 12 (5.5) 200-1I4 11/4' (32) /8'-16 M8 or M10 33/4" (94.0) 2/" (73.0) 400 (1.78) 13 (5.9) 200-1/2 11/2" (40) /8"-16 M8 or M10 3/8" (98.4) 2/8" (73.0) 400 (1.78) 14 (6,4) 200-2 211 (50) 1 3/8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 400 (1.78) 15 (6.9) 200-2/2 21/2' (65) /8"-16 M10 5/8" (142.9) 41/8" (104.7) 600 (2.67) 27 (12.3) 200-3 3° (75) /8"-16 M10 5/8" (149.1) 4" (101.6) 600 (2.67) 29 (13.3) 200-3I2 31/21 (90) /8"-16 M10 7I8" (187.3) 51/4" (133.3) 600 (2.67) 34 (15.6) 200-4 4° (100) /8'-16 M10 7I8" (187.3) 5" (127.0) 1000 (4.45) 35 (16.0) 200-5 5° (125) 1/2"_13 M12 91/8" (231.8) 61/4" (158.7) 1250 (5.56) 66 (30.2) 200-6 6' (150) 1/211_13 M12 101/8" (257.2) 6/4" (171.4) 1250 (5.56) 73 (33.4) 200-8 1 8" (0) 1/2"13 M12 131/8" (333.4) 8/4 (222.2) 1250 (5.56) 136 (62.3) B-Line by 4'j All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are In millimeters unless otherwise specified. 61 Pipe Hangers & Supports 98 - Rod Stiffener Size Ranp- Secures 3/8" thru 7/8" hanger rod Material - Ca)bqn Steel Function - Securehannel to hanger rod for vertical seismic bracing. Approvals - Included'hour Seismic Restraints Catalog approved Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Order By - Figure number Component of State of California OSHPD Approved Seismic Restraints System Fig. 99 - All Thread Rod C to Length Size Range - Secures 3/8" thru 7/8")05 in 1" increments Material - Carbon Steel Maximum Te mperature Finish - P Note - Av and HDG finish materials. Order fl(— Figure number, rod diameter, rod lentt and finish Dimensions Rod Max. Rec. Load Lbs. s.Size For Service Temp 'N. 650°F 3/8 'N. 730 1/2 'N 1350 3/4 7/8 Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 1½" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1½ 19800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com STEEL HANGERMATE ""MI& CONCRETE HANGERMATE GENERAL INFORMA11ON GENERAL INFORMATION HANGERMATE® Rod Hanging Anchors Hangermate is an all steel threaded fastening system for suspending steel Threaded rod vertically overhead in pipe hanging, fire protection, electrical conduit and cable-tray applications. They are available in versions which can be installed in a variety of base materials including steel puriins, bar joists and beams, wood frame columns and beams, as well as concrete ceilings, beams and columns. Steel threaded rods in 1/4" and 3/8" diameters can be vertically suspended with Hangermate (a 1/2" diameter size is also available for wood). They are also offered in a side mount style for lateral installation of 1/4" and 3/8" diameter steel threaded rods onto joists, columns and overhead members. For all steel and wood hangers, a Hangermate Socket Driver is recommended to provide proper installation with a drill screw gun. For concrete hangers, a powered impact tool with a clutch is recommended. A pivot head version is also available for flexible connection angle and positioning of rod hangers. An acoustical ceiling eyelet version is also available for hanging wire or cable attachments. Hanging Pipe and Sprinkler Systems • HVAC Ductwork and Strut Channels Suspending Conduit and Cable Trays • Suspeiided Ceilings Lighting Systems and Overhead Utilities • Mounting Security Equipment + Ease and speed of overhead installation + Lower in-place cost, when compared to beam clamps, lag bolts and dropins + Steel and wood Hangermate can be installed with a drill screw gun + Side mount versions available for steel and wood Hangermate + Socket drivers, pole tool and accessories to optimize ease of installation FM Approvals M) - see listing for applicable sizes and types Pipe Hangers components for automatic sprinkler systems - File No. JI 3015153 Underwriters Laboratory (UL) - see listing for applicable sizes and types Pipe Hangers - File No. EX 1289 0 0 23 OZ II EIIEBIED rr?owerr SECTION CONTENTS General Information ......................... 1 Material Specificalions ................... 2 Installation Specifications..............2 Perfonnance Data............................3 Ordering Information.......................5 ANCHOR MATERIALS Zinc Plated Carbon Steel ANCHOR SIZE RANGE (TYR) 1/4" to 3/8" for Steel 1/4" to 1/2" for Wood 1/4" to 3/8" for Concrete (Threaded Coupler Heads) THREAD VERSION Unified Coarse Thread (JNC) SUITABLE BASE MATERIALS Steel Puriins and Beams Wood and limber Concrete Members CSI Divisions: 03 16 00 - Concrete Anchors, 05 0523 - Metal Fastenings and 06 05 23 - Wood, Plastic, and Composite Fastenings. Rod Hangers shall be Hangermate anchors as supplied by DEWALT, Towson, MD. Anchors shall be installed in accordance with published instruction and the Authority Having Jurisdiction. WWW.DEWALTcOm WALT EI sr?owers- MATERIAL SPECIFICATIONS MATERIAL SPECIFICATIONS - - M Screw Body Case hardened carbon steel Coupling (UNC thread) / Eyelet Case hardened carbon steel Zinc Plating ASTM B633, SC1, Type Ill efZn5) INSTALLATION SPECIFICATIONS Steel Hanoermate Wood Hanaermate Rid GoiIsr She 1/4" 3/8" 112" Coupling Thread Size (IJNC) 1/4-20 3/8-16 1/2-13 Coupling Thread Depth (to.) 3/8 3/8 3/8 Coupling Height (in.) 13/16 13/16 13/16 Socket Driver Size (in.) 5/8 5/8 5/8 Note: the side mount couplings have full Thread depth (through head). Rod CoiiIur She 1/4" 3/8" Coupling Thread Size (UNC) 1/4-20 3/8-16 Coupling Thread Depth (in.) 3/8 3/8 Coupling Height (in.) 3/4 3/4 Socket Driver Size (in.) 1/2 1/2 Note: the side mount couplings have full thread depth (through head). Concrete Hannennate Rid CNOW Sb. 1/4H 318" ANSI Drill Bit (in.) 1/4 1/4 Overall Screw Shank Length 1-1/4 1-1/2 Anchor Thread Length (to.) 1-1/8 1-3/8 Coupler/ Washing Height (in.) 27/64 9/16 Integral Washer O.D. (in.) 31/64 39/64 Coupling Thread Size (UNC) 1/4-20 3/8-16 Coupling Thread Depth n.) 3/8 1/2 Socket Driver Size (in.) 3/8 1/2 Installation Guidelines 1. If pre-drilling is required (certain types of wood 2. Select the appropriate socket driver for the anchor 3. Thread the appropriate diameter steel threaded truss/wood joist and all concrete base materials), size and type to be installed and mount into chuck of rod or threaded bait into the coupling. The threaded select the recommended drill bit type and diameter. installation tool. Insert the Hangermate coupling into rod or bolt should fully engage the thread length the socket driver, and install perpendicular to the base of the coupling on a vertical mount fastener. The For Concrete Hangermate, drill a hole to the material surface. Drive the fastener with a smooth threaded rod or threaded portion of the bolt can pass appropriate embedment depth, adding at least 1/4" steady motion until the driver and coupling is seated through coupling of a side mount fastener. to the drilling depth to prevent the tip of the fastener against the surface of the base material. from running into the back of the anchor hole during installation. When installing Hangermate, eye protection should be worn as a safety precaution. For UL and/or FM listings for hangers Steel Hangermate should be installed with a retaining nut for parts that are packaged with a nut (see performance data and listings as applicable). Suggested drill speed for Steel Hangermate installations is 1200 to 1800 rpm. nil I Iii 1111 ii ITI 't'a ii ii Install with appropriate sized steel socket driver. Install with appropriate sized wood socket driver. Install with appropriate sized concrete socket driver (side and variable mount direction versions not pictured) (side and variable mount direction versions not pictured) (variable mount direction version not pictured) 1400-4thWAI:f PERFORMANCE DATA BlIy'owerr PERFORMANCE DATA Hanqennate for Steel - General Cat. No. Sorew Desafptlesi Mewit flkectlon Rod COUIIIS Se 1k * I I M. Thick. In. I Max. Thick. In. UL FM Max. Pipe Size IJL Thick. Max. Pipe size FM 11Ck. Hangennate For Sted - Vedical PFM2231 000 1/4-201" #3 Vert. 1/4 PFM2201200 (Silver) 0.060 0.210 - - PFM2231100 1/4-20 xl' #3 Vert. 3/8 PFM2201200 (Silver) 0.060 0.210 4" 060° - - PFM22311ON 1/4-20 xl" #3/nut Vert. 3/8 PFM2201200 (Silver) 0.060 0.210 4" 0.125" 4° 0.105 PFM2231150 1/4-20 x 1-1/2 #5 Vert. 3/8" PFM2201200 (Silver) 0.125 0.500 4" 0.060" 4" 0.060' PFM223115N l/4-20x 1-1/2" #5/nut Vert. 3/8" PFM2201200 (Silver) 0.125 0.500 4" 0.125" 4" 0.105" PFM2231200 1/4-20x 1-1/2" #3 Vert. 3/8" PFM2201200 (Silver) 0.060 0,210 4" 0.060" - PFM223120N 1/4-20 x 1-1/2" #3/nut Vert. 3/8" PFM2201200 (Silver) 0.060 0.210 4" 0.060" - - PFM2231250 1/4-20 x 2° #3 Vert. 3/8" PFM2201200 (Silver) 0.060 0.210 4° 0.125" H.Ia For Steel - Norizonbi PFM2241100 1/4-20 x 1 '#3 Side 3/8" PFM2201200 (Silver) 0.060 0,210 - - - - PFM22411ON 1/4-20 xl" #3/nut Side 3/8" PFM2201200 (Silver) 0.060 0.210 4° 0.060" 4" 0.060" PFM2241150 1/4-20x 1-1/2" #3 Side 3/8" PFM2201200 (Silver) 0.060 0,210 - - - - PFM224115N 1/4-20 x 1-1/2" #3/nut Side 3/8' PFM2201200 (Silver) 0.060 0,210 4" 0.060" 4" 0.060' PFM2241200 1/4-20x 1-1/2" #5 Side 3/8" PFM2201200 (Silver) 0.125 0.500 - - - - PFM224120N 1/4-20 x 1-1/2" #5/nut Side 1 3/8" 1 PFM221200 (Silver) 0.125 1 0.500 4" 0.060" 4" 0.060" Hanguath Pivot For Sled - Msd i,,&Ih.. PFM2281150 1/4-20 xl' #3 Variable 3/8" PFM2201250 0.060 0,188 - - - - PFM2281200 12-20 x 1-3/4" #5 Vanable 3/8" PFM2201250 0.125 0.500 - - - - PFM2281250 1/4-14 xl" #3 Variable 3/8" PFM2201250 0.060 0.188 - - - - Nongennate For Steel - AcomAllcall CeMag Screw Eyelet PFM2231500 1/4-14 x 7/8" #2(3/16" eyelet) Variable - PFM2201350 0.060 0.105 - - - - PFM2231550 1/4-14 x 2 #2 (3/16" eyelet) Variable - PFM2201350 0.060 0.105 - - - - Hanuermate for Steel - Ultimate Load Canacities when Installed In Steel, CatNo. ScmwDesciipllon rAnd I1n Rod CWft fte Sled Sang. I ihidmeca 1610.010 I I 1410.075 I I 1210.105 I I lJ5 I I 311610.187 I I 11410.250 I I 1/210.500 1hmgwWAftFor St.d - VuOcal PFM2231000 1/4-201" #3 Vertical 1/4 785 1,140 1,740 2,375 2,820 - - PFM2231100 1/4-20x1"#3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - PFM22311ON 1/4-20 xl" #3/nut Vertical 3/8 3,435 4,025 4,280 4,690 5,810 - - PFM2231150 1/4 -20 x 1-1/2" #5 Vertical 3/8 - - - - 3,675 5,205 5,205 PFM223115N 1/4-20x1-1/2' #5/nut Vertical 3/8 3,435 4,025 4,280 4,690 5,810 5,810 5,810 PFM2231200 1/4-20 x 1-1/2" #3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - PFM223120N 1/4-20 x 1-1/2" #3/nut Vertical 3/8 3,435 4,025 4,280 4,690 4,695 - - PFM2231250 1/4-20x2"#3 Vertical 3/8 785 1,140 1,740 2,375 4,695 - - Haigennate For Sted - Heibonbi PFM2241100 1/4-20 x 1" #3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - PFM22411ON 1/4-20x1" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM2241150 1/4-20 x 1-1/2" #3 Side 3/8 1,740 1,945 2,420 2,570 2,810 - - PFM224115N 1/4-20 x 1-1/2" #3/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 - - PFM2241200 1/4-20 x 1-1/2" #5 Side 3/8 - - - - 2,205 2,810 2,810 PFM224120N 1/4-20 x 1-1/2" #5/nut Side 3/8 2,755 2,810 2,570 2,810 2,810 2,810 2,810 Hangeimate Pivot Per Steel - od Applcatkins PFM2281150 1/4-20 x 1" #3 Variable 3/8 635 - Vert. (875 @45°) 635 - Vert. (875 @45°) 1,130 - Vert. (875 @45°) 1,130 - Vert. (875 @45°) 1,640 - Vert. (875 @45°) - - PFM2281200 12-20 xl -3/4" #5 Variable 3/8 635 - Vert. (875 @ 45°) 635 - Vert. (875 @45°) 1,130 - Vert. (875 @ 45°) 1,130 - Vert. (875 @45°) 1,640 - Vert. (875 @ 45°) 1,640 - Vert. (875 @45°) 1,640 -Vert. (875 @45°) PFM2281250 1/4-14 x 1" #3 Variable 3/8 590 - Vert. (875 @45°) 590 - Vert. (875 @45°) 970 - Vert. (875 @45°) 970 - Vert. (875 @45°) 1,640 - Vert. (875 @45°) - - Haligeiniate For Steel. Acouslical Celbig Screw Eyelet PFM2231500 3/16 x 2" #2 Variable - 800 800 1,245 PFM2231550 3/16x3-1/4#2 f Variable - 800 800 1,245 The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 3.0 or greater to determine the allowable worldng load. The strength of the threaded rod used with the Hangerrnate anchors must be considered when determining the controlling load capacity of the assembly. www.DEWALTcom 0 0 0 0 0 rn 0 173-77 7117U,777,771 PERFORMANCE DATA Hangermate for Wood - Ultimate Lead Capacities when Installed in Wood'-' No Sasw Description Mount Rod Coupler Direction Size M rnlvsr It FMCat 11,001111118* ul. . . . she Haupsinate For Wood - Vertical PFM2251000 1/4'x 2" Vert. 1/4 PFM2201150 (Red) 1,510 - - PFM2251050 1/4" x 1 Vert. 3/8' PFM2201150 650 - - PFM2251100 1/4" x 2" Vert. 3/8' PFM2201150 1,510 - PFM2251150 5/16" x 2-1/2" Veil. 3/8' PFM2201150 (Reo 2,670 4" PFM2251200 1/4" x 3" Veil. 3/8' PFM2201150 2,075 3" - PFM2251250 1/4" x4" Veil. 3/8' PFM2201150 2,075 3" - PFM2251300 5/16" x 2-1/2 Veil. 1/2" PFM2201150 (Reo 2,670 - - Hangermnate For Wood - Hartaoedl PFM2261000 1/4" x 1" Side 1/4" PFM2201150 650 - - PFM2261050 1/4" x 1' Side 3/8" PFM2201150 650 - - PFM2261100 1/4" x 2' Side 3/8' PFM2201150(Red) 1,800 3" - PFM2261150 5/16" x 2-1/2' Side 3/8" PFM2201150 1,450 - 3' Nongerroato Pivot For Weed - Aned uppucatiens ____________ PFM2281100 1/4x2" F Variable 3/8' PFM2201250 j I HieerMo Fir Weed -Acoosticall Ce Screw Eyotet PFM2251500 3/16'x3-114" Variable - PFM2201350 I 880 *Ultimate Loads In Douglas Fir, Pine and Spruce Trussioist manufacturers may require pm-drilled holes with wood depending on the location of the anchor installation. Consult with the tnjssioist manufacturer for details. The values listed above are ultimate load capacities that must be reduced by a minimum safety factor of 3.0 or greater to determine the allowable working load. Concrete Hangennate — Ultimate Load Capacities when Installed In Normal-Weight Concrete"2'3 ..L...,.. Canasta Csuupreeslve Slreeglh (fc) Cat N. Red Coupler Screw mad Iu!!_Bft E. 2,000 pal 46000 psi 6,000 pd Tusslen Sheer Tessin Sheer Teusis. Show DiipUi• " rn. rn. rn06 rn06 IbL rn. PFM2217171 1/4 1/4"x1-1/4" Vertical 1/4 1-1/4 1,390 1,810 1,950 2,440 2,070 2,570 PFM2271713 3/8 1/4" x 1-1/2" Vertical 1/4 1-1/2 1,760 2,580 2595 2,640 2,770 2,700 The values listed above are ultimate load capacities for anchors installed in uncracked normal weight concrete. The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Linear interpolation may be used to determine load capacities for intermediate compressive strengths. Concrete Hangennate — Ultimate Load Capacities when Installed Through Metal Deck into Lightweight Concrete' 23'4 Urtw.It Csnc,ete Over Nab. Deck f"c ~ 3,000 pd Cat NIL Red Coupler She Dft *1151 Bit DirectionWonder EeO -- -.- G Oak TensIon Lead .t 45" escription b. rn. rn. PFM2217171 1/4 1/4'x1-1/4" Vertical 1/4 1-1/4 800 1,140 PFM2271713 3/8 1/4x1-1/2" 1 Vertical 1/4 1-1/2 1,780 1,500 The values listed above are ultimate load capacities for anchors installed in uncracked sand-lightweight concrete. The metal deck shall not exceed 18 gauge (0.048-inch base metal thiciwess) and conform to ASTM A 653. The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. The tabulated load values are for anchors installed with a minimum lower flute edge distance of 1-1/8-inch; or in the upper flute with consideration for integral washer clearance. Concrete Hangennate — Ultimate Lead Capacities when Installed In Hollow Core Concrete Plank12 Cat No. Red Coupler Sb.Sam Ill *llSIlk Bit ula Tension, Center si Web Tension, Center of Core 1106 kL 106 lie. lii. PFM2217171 1/4 1/4' x 1-1/4" Vertical 1/4 1-1/4 2,775 1,920 PFM2271713 3/8 1/4x1-1/2" Vertical 1/4 1-1/2 3,700 2,570 Tabulated load values are for anchors installed in 8-inch-thick uncracked hollow core concrete with minimum compressive strength 015,000 psi at the time of installation. The normal-weight concrete must have 1-1/2" cover above and below cores and a minimum web thlcloress of 1-1/2". The values listed above are ultimate load capacities which must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load. Concrete Hangennate — Factory Mutual (FM Global) Listings for Pipe Hangers Cat No. I Rod Coupler Size Screw Description I I Mount Direction Bft I *llSl lkW Diameter ____ I DnliamhnentDepth I I I hi. I I I pipe Size PFM2271713 3/8 1 1/4" X 1-1/2" 1 Vertical 1/4 1-1/2 4" 1-8004 DWALt Cat. No. DescrIption Driver # (Silver) Mount Red Size Box Qty. Carton Qty. PFM2241100 1/4-20 x 1 '#3 PFM2201200 Side 3/8 25 125 PFM22411 ON 1/4-20 xl' #3/nut PFM2201200 Side 3/8' 25 125 PFM2241150 1/4-20 x 1-1/2" #3 PFM2201200 Side 3/8 25 125 PFM224115N 1/4-20 xl -1/2" #3/nut PFM2201200 Side 3/8" PFM2241200 1/4-20 xl -1/2" #5 PFM2201200 Side 3/8" d25125 125 PFM224120N 1/4-20x1-1/2°#5/nut PFM2201200 Side 3/8" 125 Hannermate Pivot for Steel - Annlod Annilcatlons Cat. No. DescrIption I Pivot Drivir # Mend Rod Size lax tRy. Carts. tRy. PFM2281 150 1/4-20x1_"#3 PFM2201 250 Variable 3/8" 25 125 PFM2281 200 12-20 x1-3/4"#5PFM2201250 Variable 3/8" 25 -125 PFM2281250 1/4-14 xl" #3 PFM2201 250 Variable 3/8 25 125 Hannennate Acoustical Celllno Eyelet for Steel Z C) m m ORDERING INFORMATION ORDERING Hanaeniiate for Steel - Vertical Cat. No. DescrIptIon Driver # (Silver) Mond Rod Size Box Qty. Carton Qty. PFM2231 000 1/4-20 x 1 '#3 PFM2201200 Vertical 1/4 25 125 PFM2231100 1/4-20 x "#3 PFM2201200 Vertical 3/8 25 125 PFM22311 ON 1/4-20 x 1 #3/nut PFM2201200 Vertical 3/811 25 125 PFM2231150 1/4-20 x 1-1/2 #5 PFM2201200 Vertical 3/8 25 125 PFM223115N 1/4-20 x 1-1/2 #5/nut PFM2201200 Vertical 3/8" 25 125 PFM2231200 1/4-20 x 1-1/2 #3 PFM2201200 Vertical 3/8 25 125 PFM223120N 1/4-20x1-1/2" #3/nut PFM2201200 Vertical 3/8° 25 125 PFM2231250 1/4-20 x 2" #3 PFM2201200 Vertical 3/8" 25 125 Hanoerniate for Steel - Horizontal EIOoxD .r?owers COL No. DescrIption Eyelet Drtver# Mount Eyelid Bole lox tRy. Carts. lIly. PFM2231 500 3/16" x 2 PFM2201350 1/4-14 x7/8'#2screw Variable 3/16" 25 125 PFM2231 550 3/16" x 3-1/4" PFM2201350 1/4-14 x 2' #2 screw Variable 3/16' 25 125 Hannennate for Wend - Vertical Cat. No. Description DrIver 0 (Red) Mount Rod Size lox lIly. Carton Qly. PFM2251000 1/4'_x2" PFM2201150 Vertical 1/4' 25 125 PFM2251 050 1/4'x1" PFM2201150 Vertical 3/8" 25 125 PFM2251 100 1/4"x2" PFM2201150 Vertical 3/8" 25 125 PFM2251150 5/16"x2-1/2" PFM2201150 Vertical 3/8" 25 125 PFM2251200 1/4'x3" PFM2201150 Vertical 3/8" 25 125 PFM2251250 1/4'_x 4" PFM2201150 Vertical 3/8" 25 125 PFM2251300 5/16"x2-1/2" PFM2201150 I Vertical 1/2° 25 125 Hannennate for Wood - Horizontal Cat. No. Description Driver 0 (Red) Mount Rod Size Box Qty. Cats. Qty. PFM2261 000 1/4'_x1" PFM2201150 Side 1/4" 25 125 PFM2261 050 1/4'_x1" PFM2201150 Side 3/8" 25 1 125 PFM2261100 1/4"x 2" PFM2201150 Side 3/8" 25 125 PFM2261150 5/16"x2-1/2" PFM2201150 Side 3/8" 25 125 Hannennate Pivot for Wend - Analed Anelicatlens Ct. No. I Desalplkm Pivot Driver * Mount Rod Size Box Qty. Carton lIly. PFM2281100 1 1/4" x 2" PFM2201250 Variable 3/8' 25 125 Hannormate Acoustical Cellino Eyelet for Wend Cat. N. Description Eyelet Drive, P Mount Eyelet Hole Box lIly. Carton Qty. PFM2251500 3/16" x3-1/4" PFM2201350 Variable 3/16" 25 125 www.DEWALTcom ORDERING INFORMATION EIUI mr?owers Haneerniate for Concrete - Vertical Cat No. Desc,lpuon D,tver # (Black) Momt Rod Sbo Box My. Carton Oty. PFM2217171 1/4° x 1-1/4 PFM1491050 Vertical 1/4 100 600 PFM2217173 1/4' x 1-1/2 PFM1491100 Vertical 3/8' 100 600 1. Concrete Hangermate require a pre-drilled hole using a 1/4 ANSI carbide drill bit (e.g. DW5517). Hangermate Pivot for Concrete - Angled Applications'.' Cat. No. D.sutØlon Pivot Other * Naiad Rod S. Box Qty. Caitmi Qty. PFM2281300 3/16° x 2" PFM2201250 Variable 3/8" 25 125 The Hangermate Pivot for concrete require a pie-drilled hole using a 3/16" ANSI carbide drill bit (e.g. DW5404. Ultimate load capacity for the Hangermate Pivot for concrete is 875 lbs. The ultimate load capacities must be reduced by a minimum safety factor of 4.0 or greater to determine the allowable worldng load. Concrete Installation Accessories and Tool Guide OiuUtlu Rstaiy Ha.ur Bit Max Thrilm I np&t Mar or h—act-Rat.d (It-L) Wrench Socket I ilver # mom Cat. No. DGf887 PFM1 491050 or PFM2217171 1/4" Vertical Hanger DCH273P2DH DW5416 DW5517 150 (1/4" Impact Driver) DWMT17311 0CF890 DW2284 (3/8") 1/4"x1-1/4" (1/4") (3/8" Impact Wrench) DCF887 PFM1491100 or PFM2217173 3/8' Vertical Hanger DCH273P2DH DW5416 DW5517 150 (1/4' Impact Driver) DWMT17311 DCF890 r(3/8'Impact 0W2286 (1/2) 1/4" x 1-1/2" (1/4") Wrench) Steel and Wood Hanaermate Pole Tool Cat No. Desatlan I Std. Pack PFM2201100 Hangermate Pole Tool (J(it) 1 The Hangermate pole tool kit is designed for use with standard 1/2" steel conduit tubing (conduit not include( and can be customized to various lengths and ceiling heights. Compatible with standard steel and wood Hangermate. Steel and Wood Hanaermate Pole Tool Cit No. DesaiIlen Std. Pack PFM2201200 1/4" & 3/8" Steel Hangermate Driver - Vertical and Horizontal Mounts (Silver) 5 PFM2201150 1/4" & 3/8" Wood Hangermate Driver - Vertical and Horizontal Mounts (Red) 5 PFM1491050 1/4" Concrete Hangermate Driver - Vertical Mount (BlacI 5 PFM1 491100 3/8" Concrete Hangermate Driver - Vertical Mount (Black) 5 PFM2201250 Hangermate Pivot Driver - Angled Mounts 5 PFM2201350 Hangermate Eyelet Driver - Angled Mounts 5 All Hangermate drivers have a 1/4-inch hex for connection to tools. Universal Installation Accessories Cat No. Descilpllco I Std. Pack PFM2201050 3/8" to 1/2" Adapter The 3/8" to 1/2' adaptor has a 3/8-16 external thread and a 1/2-13 internal thread. 1-aoo-4thWALY