Loading...
HomeMy WebLinkAbout1435 YOURELL AVE; ; AS160345; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160345 Job Address: 1435 YOURELL AV Permit Type: SPRINK Parcel No: 1560520400 Lot #: 0 Status: ISSUED Applied 10/25/2016 Approved: 10/25/2016 Reference No.: Issued: 10/25/2016 PC #: Inspector: Project Title: LLOYD RESIDENCE INSTALLATION OF SPRINKLER 13D SYSTEM Applicant: ALWAYS FIRE PROTECTION CHRIS FOX 1451 KENT AV. ESCONDIDO, CA 760-535-9234 Owner: GLEASON LAUREN D LIVING TRUST 06- 11-09 36540 SILVER SPUR RD TEMECULA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 348 0 348 348 HYDRAULIC DESIGN INFORMATION SHEET Name: Lloyd Residence Date: September 20, 2016 Location: 1435 Yourell Avenue System No.: Carlsbad, CA 92008 Contract No.: Building: Drawing No.: Contractor: Lloyd & Associates Calculated by: B.R. File Name: Lloyd Res 9-20-16.the Construction: II Combustible 0 Noncombustible Ceiling Height: 12'-6" ft Occupancy: Single Family Dwelling AHJ: Carlsbad Fire Department SYSTEM DESIGN O NFPA 13: {J Light Hazard Ordinary Hazard Group: 0 Extra Hazard Group: Figure: Curve: fI Other (Specify): NFPA 130 O Specific Rulling: Made By: Area of Sprinkler Operation: 256 sqft System Type: EI Wet 0 Dry 0 Deluge 0 Pre-Action Density: .05 gpm/sqft Area per Sprinkler: 256 sqft SPRINKLER or NOZZLE Hose Allowance Inside: gpm Make: Tyco Model: LF II Hose Allowance Outside: gpm Size: .5 in K-factor: 4.9 Rack Sprinkler Allowance: gpm Temperature Rating: 160 OF CALCULATION SUMMARY Flow Required: 31.53 gpm Pressure Required: 52.36 psi At: SRC 'C Factor Used: Overhead: 150 Underground: 150 WATER SUPPLY WATER FLOW TEST PUMP DATA TANK OR RESERVOIR Date: 9-19-16 Rated Capacity: gpm Capacity: gals Time: 10:00 AM At: psi Elevation: ft Static: 64.95 psi Elevation: ft Residual: 63.95 psi WELL Flowing: 50 gpm Proof Flow: gpm Elevation: 179 ft Location: 1435 Yourell Avenue Carlsbad, CA 9200 Source of Information: Carlsbad Municipal Water Nelson COMMODITY STORAGE Commodity: Class: Location: Storage Height: Area: Aisle Width: Storage Method: Solid Pile: % Palletized: % Rack: % RACK STORAGE Single Row IJ Conventional Pallet 0 Automatic Storage 0 Encapsulated F1 Double Row 0 Slave Pallet J Solid Shelving 0 Nonencapsulated F] Multiple Row 0 Open FLUE SPACING CLEARANCE FROM TOP OF STORAGE TO CEILING Longitudinal: in Transverse: in ft in Horizontal Barriers Provided: AS 1 60345 1435 YOU RELL AV Date: File: Lloyd Res 9-20-16.the Page 1 of 1 Hydraulic Summary WATER SUPPLY INFORMATION Static (psi): 58.46 Residual (psi): 57.56 @ (gpm): 50.00 Hose (gpm): 0.00 System req. (gpm): 31.53 @ (psi): 52.36 Supply available: 58.08 psi Safety margin: 5.72 psi Maximum velocity in the system is: Continuity at all nodes satisfied to: Pipe Type Legend CP = Central - BlazeMaster CPVC CL = Copper Type L PP = PVC CK = Copper Type K 13.01 ft/sec in the pipe between Nodes: SRC and U3 0.01 gpm Fitting Type Legend E = 90 degree elbow = Tee - Flow thru branch F = 45 degree elbow H = Tee - Flow thru run C = Check valve U = Flow Indicator N =90 degree elbow M = 45 degree elbow NOTES 09/20/16 "THE" Sprinkler Program 2001 File: Lloyd Res 9-20-16.the Page 1 of 1 Node Pressure Flow Hose Elevation K-factor Area Density psi gpm gpm feet gpm/(psi)1/z sqft gpm/sqft 1 7.05 13.00 187.830 4.90 256.00 0.051 2 7.64 13.53 187.830 4.90 256.00 0.053 A 9.57. 0.00 186.990 Al 14.56 0.00 188.330 A2 19.00 0.00 188.330 TOR 24.38 0.00 186.740 BOR 29.71 5.00 5.00 178.160 BFI 42.33 0.00 179.000 BF2 35.16 0.00 177.000 Ui 32.62 0.00 174.240 U2 34.76 0.00 177.000 U3 42.42 0.00 179.000 SRC 52.36 31.53 177.000 Source 09/20/16 "THE" Sprinkler Program 2001 File: Lloyd Res 9-20-16.the Page 1 of 2 Node Node Node Flow Node Flow Pipe Flow K-factor Elevation K-factor Elevation Pressure Pressure Diameter HWC Velocity Fittings Length Fric Loss Eqv Length Elev Loss Ttl Length Ttl FL 1 13.00 4.90 187.83 7.05 1.101 10.770 0.031 2 13.53 4.90 187.83 7.64 150 E I 8.500 0.00 13.00 4.38 19.270 0.59 2 13.53 4.90 187.83 7.64 1.101 6.600 0.115 A 0.00 186.99 9.57 150 E 2F H 7.000 0.36 26.53 8.94 13.600 1.56 A 0.00 186.99 9.57 1.101 25.270 0.115 Al 0.00 188.33 14.56 150 E2F31 23.300 -0.58 26.53 8.94 48.570 5.57 Al 0.00 188.33 14.56 1.101 23.410 0.115 A2 0.00 188.33 19.00 150 E4H I 15.300 0.00 26.53 8.94 38.710 4.44 A2 0.00 188.33 19.00 1.101 25.800 0.115 TOR 0.00 186.74 24.38 150 4E 3H 15.100 0.69 26.53 8.94 40.900 4.69 BOR 5.00 178.16 29.71 1.101 8.580 0.115 TOR 0.00 186.74 24.38 150 C U 5.500 3.72 26.53 8.94 14.080 1.62 UI 0.00 174.24 32.62 1.265 6.000 0.080 BOR 5.00 178.16 29.71 150 3N 9.000 1.70 31.53 8.05 15.000 1.20 U2 0.00 177.00 34.76 1.394 63.000 0.050 UI 0.00 174.24 32.62 150 2F 3.781 -1.20 31.53 6.63 66.780 3.34 BF2 0.00 177.00 35.16 1.394 4.000 0.050 U2 0.00 177.00 34.76 150 E 3.991 0.00 31.53 6.63 7.990 0.40 BFI 0.00 179.00 42.33 1.245 8.000 0.087 BF2 0.00 177.00 35.16 150 4N 2C 22.000 -0.87 31.53 8.31 30.000 8.04 The Flow Dependent Pressure Loss Device in this pipe accounts for 5.43 psi of the total friction loss. U3 0.00 179.00 42.42 1.245 1.000 0.087 BF1 0.00 179.00 42.33 150 0.000 0.00 31.53 8.31 1.000 0.09 SRC 31.53 Source 177.00 52.36 0.995 10.000 0.259 U3 0.00 179.00 42.42 150 2M 2.000 0.87 31.53 13.01 12.000 9.08 The Flow Dependent Pressure Loss Device in this pipe accounts for 5.97 psi of the total friction loss. 09/20/16 "THE" Sprinkler Program 2001 File: Lloyd Res 9-20-16.the Page 2 of 2 Node Node Flow K-factor Elevation Pressure Diameter Length Fric Loss Node Node Flow K-factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity Ttl Length Ttl FL Units Legend Flow = gpm Elevation = feet Pressure = psi Diameter = inches Velocity = ft/sec Length, Eqv Length, Ttl Length = feet Fric Loss = psi/ft Elev Loss, Ttl FL = psi 09/20/16 'THE" Sprinkler Program 2001 Water Supply vs. Sprinkler Demand 80 - 70 60 - 50 58 32@52 50 CL ;40 (0 (0 a) 3C 0 20 40 60 80 100 120 140 Flow (gpm) Fire Protection Products Worldwide www.tyco-fire.com Contacts RAWD RESPONSE Series ILFHY Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (1Y2524) are dec- orative, fast response, fusible solder sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. The Cover Plate/Retainer Assem- bly conceals the sprinkler operating components above the ceiling. The flat profile of the Cover Plate provides the optimum aesthetically appealing sprinkler design. Additionally, the con- cealed design of the Series LFII Resi- dential Flat-Plate Concealed Pendent Sprinklers provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Flat- Plate Concealed Pendent Sprinklers are intended for use in the following systems: wet and dry pipe residential sprinkler systems for one- and two- family dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page I of 6 The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap protects the sprinkler during ceiling installation or finish. After ceiling installation is com- plete, the Protective Cap is removed and the Cover Plate/Retainer Assem- bly is installed. Removing the Protec- tive Gap is required for proper sprinkler performance. Dry Pipe System Application The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residen- tial sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Flat-Plate Concealed Sprinklers (TY2524) need not be increased over the number of design sprinklers (hydraulic design area) specified for wet pipe sprinkler systems, as is customary for density/ area sprinkler systems designed per NFPA 13,13D, or 13R. Consequently, the Series LFII Resi- dential Flat-Plate Concealed Sprin- klers (TY2524) offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. JANUARY 2016 The Series LFII Residential Flat- Plate Concealed Pendent Sprinklers (TY2524) described herein must be installed and maintained in compli- ance with this document and the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or sprinkler manufacturer with any questions. 1.iI1ii$i1ltI TFP843 TFP443 Page 20f6 lli!il1/ .t Approvals UL and C-UL Listed Certified to all requirements of NSF/ANSI 61 BODY SEALING ASSEMBLY (1/2' NP-0 CAP SPRINKLER 11111 WRENCHING AREA SADDLE COMPRESSION SUPPORT SCREW CUP WITH ROLL FORME THREADS LEVER GUIDE PIN _____ SOLDER LINK ELEMENT I' GUIDE PIN I II HOUSING DEFLECTOR / I I I DEFLECTOR C . (OPERATED POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO I I RETAINER SUPPORT -ii WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS FLUSH WITH CEILING EJECTION SPRING SOLDER' COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only listed with the Series LFII Concealed Cover Plates having a factory-applied finish. These Cover Plates and their part numbers can be found in the Ordering Procedure section at the end of this data sheet. (Refer to the Design Criteria section for details on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 4.9 GPMJpsi (70,6 LPM/bar') Temperature Rating Sprinkler: 160°F (71°C) Cover Plate: 139°F (59°C) Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to the Ordering Procedure section Physical Characteristics Cover Plate/Retainer Assembly: Cover Plate .......................Copper Ejection Spring ..............Stainless Steel Retainer ...........................Brass Sprinkler/Support Cup Assembly: Body ..............................Brass Cap ..............................Bronze Saddle.............................Brass Soldered Link Halves Nickel Lever.............................Bronze Compression Screw..................Brass Deflector ..........................Bronze Guide Pin Housing ..................Bronze Guide Pins ........................Bronze Support Cup .......................Steel Sealing Assembly. .Beryllium Nickel w/TEFLON When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. At this point, the Deflec- tor, supported by the Guide Pins, drops down to its operated position. The Solder Link Element of the Sprin- kler/Support Cup Assembly is com- prised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprin- kler to activate and flow water. The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinklers (1Y2524) are UL and C-UL Listed for installation in accordance with this section: Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the authority having jurisdiction. System Type Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of Residential Sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 130 or NFPA 13R, the minimum required sprinkler flow rate are given in Tables A and B as a function of tempera- ture rating and the maximum allow- able coverage areas. The sprinkler flow rate is the minimum required dis- charge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. TFP443 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressurel'1 Maximum Maximum Coverage Spacing Ordinary Temp Rating Area(-) Ft. x Ft. Ft. 160-F (71-C) Deflector to Installation Minimum (m x m) (m) Ceiling Type Spacing Flow Pressure GPM PSI Ft. (m) (Llmin) (bar) 12x12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 7/8to1-1/8 inches. 14x14 14 13 7.0 (4,3 x 4,3) (4,3) 49.2) (0,48) Beamed 16 x 16 (4,9 X 4,9) 16 (4,9) 13 (49,2) 7.0 (0,48) Ceilings per NFPA 130 Concealed a (2,4) 13R, or 13 Installed in beam 7/8to 18x18 18 17 12.0 (5,5 x 5,5) (5,5) (64,3) (0.83) 1-1/8 inches below bottom 20 x 20 20 20 16.7 of beam (6,1 x6,1) (6,1) (75,7) (1,15) For coverage area dimensions less than or between those indicated, use the minimum required flow for the n e x t h i g h e s t c o v e r a g e a r e a f o r which Hydraulic Design section under the Design criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (LPM) from each sprinkler. The ass o c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u - lated using the nominal K-factor. Refer to 'Hydraulic Design in the Design Criteria section for details. For NFPA 13 residential applications, the greater of 0.1 gpm/ttz over the design area or the flow in accord a n c e w i t h t h e c r i t e r i a i n t h i s t a b l e must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2524) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (b) Maximum Maximum Coverage Areat°1 Spacing Ordinary Temp Rating 160°F (71°C) Minimum Ft. x Ft. Ft. (m) Deflector to Installation Spacing Flow Pressure (m x m) Ceiling Type Ft. GPM Psi (m) (L/min) (bar) 12x12 12 15 9.4 (3,7 x 3,7) (3,7) (56,8) (0.65) Smooth Ceilings 7/8to1-1/8 14x14 14 15 94 (4,3 x 4,3) (4,3) (56,8) (0,65) inches. Beamed 16x16 (4,9 x 4,9) 16 (4,9) 16 (60,6) 10,7 (0,74) Ceilings per NFPA 130 Concealed 8 (2,4) 13R, or 13 Installed in beam 7/8to 18x18 18 17 12.0 (5,5 X 5.5) (5,5) (64,3) (0,83) 1-1/8 inches below bottom 20 x 20 20 21 18,4 of beam (6,1 x6,1) (6,1) (79,5) (1,27) For coverage area dimensions less than or between those indicated, use the minimum required flow f o r t h e n e x t h i g h e s t c o v e r a g e a r e a f o r which Hydraulic Design section under the Design Criteria are stated. The Minimum Flow requirement is based on minimum flow in GPM (1PM) from each sprinkler. The associated r e s i d u a l p r e s s u r e s a r e c a l c u - lated using the nominal K-factor. Refer to "Hydraulic Design" in the Design Criteria section for detail s , For NFPA 13 residential applications, the greater of 0.1 gpm/1t2 over the design area or the flow in accordance with the criteria in this table must be used, TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY2 5 2 4 ) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP443 Page 4 of 6 2-1/2' DIA. SPRINKLER- (63,5 mm) 1/2° (12,7 mm) FACE OF SUPPORT CUP -7 SPRINKLER 1/2" THREADED SPRINKLER ASSEMBLY N ADJUSTMENT FITTING OPERATED ER - 1 718'±1/4" COVER (3,2 mm) PLATE /8° GAP ±6,4 mm) RETAINER ' (47,6 mm H 7/8' (22,2 mm) I COVER- SPRINKLER- j MOUNTING 1-1/8' (28,6 mm) RETAINER SUPPORT CUP SURFACE I ASSEMBLY ASSEMBLY (4,8 mm) I \ 3-3/16° DIA. DISPOSABLE I SABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 2 RAPID RESPONSE SERIES LFII RESIDENTIAL FLAT-PLATE (TV2524) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable coverage area A minimum discharge of 0.1 gpm/ ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when design- ing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Flat-Plate Concealed Pendent Sprin- klers (TY2524) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Install sprinklers relative to the ceiling mounting surface (Ref. Figure 2). The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup can delay sprinkler operation in a fire situation. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A) being hydraulically calculated (e.g., a maximum of 12 feet for a 12 ft. x 12 ft coverage area or 20 feet for a 20 ft. x 20 ft. coverage area). The TYCO RAPID RESPONSE Series LFll Residential Flat-Plate Concealed Pendent Sprinklers must be installed in accordance with this section: General Instructions Damage to the Solder Link Element during installation can be avoided by handling the sprinkler by the Support Cup only; that is, do not apply pres- sure to the Solder Link Element (Ref. Figure 1). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate/Retainer Assembly by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers in the pendent position, with the center- line of the sprinkler perpendicular to the mounting surface. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 18 SPRINKLER WRENCH Step 2. Remove the Protective Cap. Step 3. With pipe-thread sealant applied to the pipe threads, and using the W-Type 18 Wrench (Ref. Figure 3), install and tighten the Sprinkler! Support Cup Assembly into the fitting. The W-Type 18 Wrench accepts a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup (Ref. Figure 2). The Protective Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. TFP443 Page 5 of 6 LL As long as the protective Cap remains in place, the system is considered "Out Of Service' Step 5. After the ceiling has been completed with the 2-112 inch (63 mm) diameter hole and in preparation for installing the Cover Plate/Retainer Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate! Retainer Assembly until its flange contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Mount- ing Cup or the Cover Plate/Retainer Assembly cannot be engaged suffi- ciently to contact the ceiling, the Sprin- kler Fitting must be repositioned. 11111111V~1111 4 111111:4 4 T_~t _11111i, ~, If IT I The TYCO RAPID RESPONSE Series LFII Residential Flat-Plate Concealed Pendent Sprinkler (TY2524) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling needs repainting after sprinkler installation, exercise care to ensure that the new paint does not seal off any of the air gap. Failure to do so may impair sprin- kler operation. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Retainer. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or overheated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. For warranty terms and conditions, visit www.tyco-fire.com. Contact your local distributor for avail- ability. When placing an order, indicate the full product description and Part Number (PIN). Sprinkler/Support Cup Assembly Specify: Series LFII (TY2524), K = 4.9 (70 6), Residential Flat-Plate Concealed Pendent Sprinkler without Cover Plate/ Retainer Assembly, P/N 51-114-1-160 Cover Plate/Retainer Assembly Specify: Series LFII (TY2524), K = 4.9 (70,6), Residential Flat-Plate Concealed Pendent Sprinkler Cover Plate/Retainer Assembly with (specify) finish, P/N (specify): Ivory (RAL 1015)...............56-202-0-135 Beige (RAL 1001) .............. 66-202-2-135 Pure White" (RAL 9010) ........56-202-3-135 Signal White (RAL 9003).......56-202-4-135 Grey White (RAL 9002) .........56-202-5-135 Brown (RAL 8028) .............56-202-6-135 Black (RAL 9005)..............56-202-7-135 Brushed Brass ................56-202-8-135 Brushed chrome ..............56-202-9-135 Custom Paint .................56-202-X-135 Previously known as Bright White Eastern Hemisphere sales only Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 TFP443 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright® 2016 Tyco Fire Products, LP. All rights reserved. tqc cr TEFLON is trademark of The DuPont Corporation Fire Protection Precincts Worldwide I www.tyco-firecom Contacts RAPID "I"IESPONSE Series LFH Residential 9-factor Pendent Sprinkler Wet irzand Dry Pipe Systems i TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions- JANUARY 2016 Sprinkler Mumic-per (Simi, Approvals UL Listed (for use with wet pipe and dry pipe systems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section for details on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi112 (70,6 1pm/bar112) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame .............................Brass Button ...........................Copper Sealing Pssembly., Beryllium Nickel w/TEFLON Bulb (3 mm) ............ ............ Glass Compression Screw .................Bronze Deflector ..........................Bronze TFP400 TFP400 Page 2 of 6 7/16' (11,1 mm) ,, ESCUTCHEON Components: NOMINAL NPT PLATE SEATING MAKE-IN SURFACE 1 - Frame 2-Button 3 - Sealing Assembly 1 4-Bulb 5 - Compression 2 / Screw 2-1/4" 6 - Deflector* -- (57,2 mm) _________ 1-5/8" (41,3 mm) * Temperature H rating is indicated on 6* Deflector. CROSS SECTION PENDENT 2-7/8" DIA. (73,0 mm) WRENCH W) STYLE 20 FLATS RECESSED ESCUTCHEON RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design CrEte rii The TYCO RAPID RESPONSE Series LFIl Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 130 or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. The number of "design sprinklers" specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFlI Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). TFP400 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Ordinary Temperature Rating Intermediate Temperature Rating Coverage 155°F (68°C) 175°F (79°C) Minimum Area 1 Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (m x m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (048) (49,2) (0,48) Ceilings 1-1/4 to 14x14 (4,3 x 4,3) 13 (49.2) 7.0 (0,48) 13 (49.2) 7.0 (0,48) 4inches Recessed Beamed using Style 20 16x16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 130 or 13R non-recessed per NFPA 130, 13R, or 13 (2,4) 18 x 18 17 12.0 17 12.0 (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) - (1,15) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highes t c o v e r a g e a r e a f o r w h i c h h y d r a u l i c d e s i g n criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calc u l a t e d u s i n g t h e n o m i n a l K-factor. Refer to Hydraulic Design under the Design criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/tt.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure (2)(3) Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (1) 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. Deflector to Installation Spacing (mxm) Flow Pressure Flow Pressure Ceiling Type Ft. gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 X 3,7) (49,2) (0.48) (49,2) (0,48) Ceilings 1-1/4 to 4 14 X 14 (4,3x4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) inches Beamed Recessed using Style 20 16x16 15 9.4 15 9.4 Ceilings Escutcheon or 8 (4,9x4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 130 or 13R non-recessed per NFPA 130, 13R, or 13 (2,4) 18 x 18 18 13.5 18 13.5 (5,5x5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1x6,1) (79,5) (1,27) (79,5) (1,27) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow fo r t h e n e x t h i g h e s t c o v e r a g e a r e a f o r w h i c h h y d r a u l i c d e s i g n criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are ca l c u l a t e d u s i n g t h e n o m i n a l K-factor. Refer to Hydraulic Design under the Design criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmlft.S over the design area or' e flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 4 of 6 WR ENCH RECESS (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH - 2-7/8 DIA. 7/16±1/8° (73,0 mm) 1/2" (12,7 mm) (11,1±3.2 mm) 2-1/4" DIA. 1/4 (6,4 mm) FACE OF (57,2 mm) . SPRINKLER \ MOUNTING FITTING ,rr1 PLATE \ / MOUNTING I SURFACE/ (3,2m) 1- 3/8 (34,9 mm) / CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH frI)Ifn'I TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-(bs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFll Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFlI Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 5 of 6 1Care and (:1.jl • ,: J,r' TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. d1E For warranty terms and conditions, visit www.tyco-fire.com. Ordering Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (PIN). Sprinkler Assemblies Specify: Series LFll 4.9K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass.................51-201-1-155 Pure White (RAL 9010)' .........51-201-3-155 Signal White (RAL 9003) ........51-201-4-155 Chrome Plated................51-201-9-155 175°F (79°C) Natural Brass .................51-201-1-175 Pure White (RAL 9010)' .........51-201-3-175 Signal White (RAL 9003) ........51-201-4-175 Chrome Plated................51-201-9-175 * Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of the DuPont Corporation. Prothw:: STANDARD MATERIALS LIST Part Name Material Body, Caps, Ball Valve Shutoffs, Test cocks Bronze C89836 (Lead Free*) Check Valve Cartridges Glass-Filled PRO Springs 300 Senes Stainless Steel Seat Discs Chloramine-resistant Silicone 0-rings Chlorarnine-resistant EPOM 1 A nfl! /-pOW) Valves SUBMITTAL SHEET Model DCLF 4A Dni ihie Check Valves Job Name: Job Location: Engineer. Contractor Tag: P0 Number: Representative: Wholesale Distributor. -J DESCRIPTION The Apollo' Model DCLF4A Lead Free* Double Check Valves prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are objectionable to the potable water supply, but non-health hazards. The top accessed modular check valve cartridges provide captured springs, replaceable seats and reversible silicone seat discs. This Made in America assembly features Apollo0 ball valves with stainless steel handles and nuts as standard and carries the five-year Apollo' factory warranty. FEATURES Low pressure loss documented by independent approval agencies Easily removable modular check valve cartridge Captured stainless steel springs Apollo0 bail valves WI SS handles & nuts standard Top-mounted test cocks for easy testing No special tools required Chloramine-resistant elastomers Designed, cast, machined, assembled and tested IN THE USA PERFORMANCE RATING Maximum Working Pressure 175 psi Temperature Range 33'F - 180'F APPROVALS ASSE 1015 - Horizontal and Vertical Flow Up (W'-21 CSA B.64.5 - Horizontal and Vertical Flow Up (½_20) Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California - Horizontal and Vertical Flow Up (1/2"2") DIMENSIONS Model Number Size (in.) Dimensions (in.) Wt. (lbs.) A Acmoi B C D 4ALF103-12F 1/2' 11-1/8 12-9/32 7-3/8 3-1/4 2-1/2 4.4 4ALF-104-72F 3/40 12-3/4 14-9/32 8-1/2 3-1/2 3 6.0 4ALF-105-T2F 1" 14-5/8 16-7/32 9-1/2 4 3-1/4 10.0 4ALF-106-T2 1_1140 18-5/8 20-5/32 1-3/4 4-1/2 4-3/4 14.0 4ALF-107-12 1_1fl0 18-3/4 20-31/32 11-5/8 4-1/2 4-3/4 17.0 4ALF-108-T2 20 21-1/8 22-13/16 12-3/4 5 5-318 25.4 j&4 I - I rj- E - *LEAD FREE: The wetted surfaces of this product shall contain no more than 0.25% lead Apollo Valves, Manufactured by Conbraco Industries, Inc. by weighted average. Complies with CAABI9S3, WAct 193, MD HB372, LA HB471 and 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA Federal Public Law 111-380. ANSI 3rd partyapproved and listed www.apoIlovalves.com 1(704) 841-6000 This ped&ationisvidef(urefeencewdy. (bwwhuIusfria Inc iena the httocbaneanypoUonofthssp&ffwIionwilhoufnWiceandwithoutincurring obligo1bntomasch changes WonbmwproduouswsubequfaIfrsaId Pfeaserâi1ou,webiite@wwoUwafmiomf&thmosfwieflinformatian SS1206003/14Pagelof2 • - _,-- / - ---. ---- -.--- - , 7 --- • 314_ - .112 — - 10 20 30 40 RATE OF FLOW (GPM) 7.5 fps r 7.5 fps I 1I4 20 18 it- 16 cn 14 Ca) 9 12 0 10 20 30 40 50 60 70 80 90 100 110 RATE OF FLOW (GPM) 1.311J5 a ut 'DIIJL -•----- ..- ----- ---- iir>" 0 20 40 60 80 100 120 140 160 180 200 220 240 RATE OF FLOW (GPM) 20 Is 16 a. 7 0 20 18 16 14 9 12 Lu Ir to .41 'Apoio' Valves S BMITTALSHE!T Model DCLF 4A Double Check Valves FACTORY CODE V-STRAINER SIZE 4A = Standard 10 0= Standard 0 3= 1/2" 4ALF= Lead Five 10 1= w/Y-strainer 0 4= 3/4" (shipped loose) 0 5 = 1 0 6= 1-1/4° 7= 1-1/2" 8=2' FLOW CURVES 0 Meter Rated Flow 7.51ps 1)2 7.5fps314 SHUT-OFF VALVES I OPTIONS (CAN BE COMBINED) El 1= less ball valves (UL classified 314°-fl El F = SAEthreaded test cocks (standard 1/2"3I4' 1") El 2= w/ball valves (Standard) El LL= locking lever handles (1-1/4 1_1/22* El 4= w/union ball valves El LT = Locking tee handles (3/4"-1') El P11= Press El P = Push (3/4"11 Curves developed from independent approval agencies actual tests - Consult factory for details. indicates rated flow as determined by approval agencies, 7.5 ftlsecis the typical maximum Plumbing system flow rate. Apollo Valves, Manufactured by Conbraco Industries, Inc. 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA www.apolIovalves.com 1 (704) 841-6000 misspecafira8ona(pmWddforffferenceonly. obI1omolsuththo(onbawproduWworsubiequsuUysoM PIeaevMarrstri(e@wweuollocthemotwua,i1Womw1i,s 551206 ©03/14 Page 2of2