HomeMy WebLinkAbout2229 PALOMAR AIRPORT RD; ; FA070005; PermitCity of Carlsbad
Fire Alarm Permit
Permit No: FA070005
2229 PALOMAR
Job Address:
AIRPORT RD
Permit Type: FALARM
Parcel No: 2130702900
Lot #: 0
Reference No.:
PC #:
Status: ISSUED
Applied 1/4/2007
Approved: 1/4/2007
Issued: 1/4/2007
Inspector:
Project Title: HAMPTON INN TWO FIRE ALARM INSPECTIONS @ $62/EA
Applicant:
DC ASSOCIATES
3671 INDUSTRY AV
LAKEWOOD, CA
562-988-8525
Owner:
AGO HILLS LLC
C/O EDWARD G COSS
620 NEWPORT CENTER DR
NEWPORT BEACH CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
124 0 124 0
DCA
D C Associates Inc.,
Complete Fire Alarm System
Material Submittal
Preparedfor.'
APPR
RTMP1
OVEDUBITTED
CARLSBAIA I . 1
Hampton Inn
Carlsbad, CA 92011
email: rcruz@dcalarm.com
Phone: (562) 988-8525 Fax: (562) 988-0964 24-Hour Service: (562) 988-8545
C
r L
9
Hampton Inn
6106 Yarrow Drive
Carlsbad, CA 92011
Manufacturer Device Model #1 Description C.S.F.M. #
Siemens MXL Fire Alarm Control Panel 7170-0067:154
Silent Knight 5129 Digital Communicator 7300-0559:120
Siemens RCC-3 Remote Annunciator 7300-0067:152
Wheelock PS-12124-8MP Power Supply 7315-0785:115
Siemens TRI-D Dual Input Module 7300-0067:146
Siemens TRI-R Single Input w/ Relay 7300-0067:146
Siemens TRI-B6M Monitor Module 7300-0067:146
Siemens ICP-B6 Intelligent Control Point 7300-0067:172
E.S.T PAM-1 Relay 7300-0067:172
Siemens MSI-10B Manual Station 7300-0067:145
Siemens FP-11 Intelligent Smoke Detector 7272-0067:203
include with:
DB-1 1 Detector Base 7300-0067:134
Siemens FP-1 1 Intelligent Smoke Detector 7272-0067:203
include with:
ADBX-1 1 Sounder Base 7300-0067:134 . Siemens. FPT-1 1 Intelligent Thermal Detector 7270-0067:202
include with:
DB-1 1 Detector Base 7300-0067:134
Wheelock AS-24MCCH-FW 177cd Ceiling-Mounted Horn Strobe (White) 7125-0785:131
Wheelock RSS-24MCW-FW 15cd Wall-Mounted Strobe (White) 7125-0785:141
include with:
RSS-24MCW-FW 30cd Wall-Mounted Strobe (White) 7125-0785:141
RSS-24MCW-FW 110cd Wall-Mounted Strobe (White) 7125-0785:141
Wheelock AS-24MCW-FW 15cd Wall-Mounted Horn Strobe (White) . 7125-0785:131
include with:
AS-24MCW-FW 30cd Wall-Mounted Horn Strobe (White) 7125-0785:131
Wheelock MIZ-24S-W Mini Horn 7135-0785:115
Wheelock MB-G10-24-R Flow Bell 7135-0785:113
AAMES DH1224 24V Electromagnetic Door Holder 3550-1039:100
S
Fire Safety
Advanced Protection System
ENGINEER AND ARCHITECT SPECI FICATIONS
UUKL Listed for Smoke Control
FirePrintTM Application Specific
Detection
Capacity for over 2,000 Intelligent
Input Devices
Dynamic Supervision of Intelligent
Devices
Security Device Monitoring
Sprinkler Supervision
Intelligent/Analog Detection Circuits,
Style 6 (Class A) or Style 4 (Class B)
Detector Sensitivity Readout/Printout
per NFPA 72 Chapter 7
Style D (Class A) or Style B (Class B)
Conventional Initiating Circuits
Style Z (Class A) or Style (Class B)
Notification Appliance Circuits
Degrade Mode Operation
Distributed Processing
80 Character Backlit Alphanumeric
Display
Thermal Strip Printer
Supervised Remote Printer
32 Character Custom Messages
Multiple Command Stations
Compare System Software
Fully Field Programmable Via Laptop
Computer
Menu Driven Operator Commands
Central & Distributed Architecture
800 Event History Logging
With On Line & Off Line Reports
User Help Screens
Multiple Levels of Password Protection
Automatic Environmental
Compensation for Smoke Detectors
One Person Walk Test by Loop,
Zone or System
Alarm Verification by Device or Zone
Logic Controlled Output Functions
Time Base Controlled Output
Functions
Holiday Schedule
a Citylie/Lease Line
Coded Outputs
Supervised Serial Annunciator
Driver/Input Interface
Interactive VDT - Monochrome
& Color
Color Graphics Option
Complies with NFPA 72
NEC 760 Power Limited Circuits
(UL 864 Compliant)
a 16 Gauge Steel Enclosure
® Listed 864, 1076, ULC Listed
a FM, CSFM, NYMEA, City of
Chicago and U.S. Coast
Guard Approved
Pre-action Releasing (NFPA 13)
a FM Approved for Sprinkler &
Deluge
FM Approved for Intrinsically
Safe Applications
Halon & FM-200 Releasing Ap-
proval (NFPA 12A & NFPA 2001)
Multi-Language Display
Intelligent Interface to Building/
Process Management Systems
Operates as an Interactive Peer
with Other MXLs, MXL-IQs or
MXLVs in a LifeLink Network
CXL Command Center
Monitoring
Pre-Alarm Operation
FireFinder Graphics
Introduction
The MXL is a microprocessor based advanced
protection system. Its use of unique multiprocessor
"Network" design along with its ability to utilize both
analog and conventional detection devices make it the
most flexible and reliable system in the life safety
field. . The MXL is ideally suited for commercial, institutional
and industrial fire detection and notification applica-
tions. It complies with the requirements of NFPA
Standard 72 and is listed by Underwriters Laboratories
under their standard 864. Underwriter's' Laboratories
of Canada also lists it for fire applications. It is
approved by Factory Mutual as well as CSFM, the City
of Chicago and NYMEA for use in those specific
locales.
In addition to the standard fire applications, MXL is
listed by Underwriters Laboratories under the category
UUKL for smoke control. MXL can be used as a listed
Fireman's Smoke Control Station in high-rise office
building, malls and other large structures. It also
complies with Uniform Building Code Section 905
requirements for smoke control.
CATALOG NUMBER 5000
S
MXL is approved by the US Coast Guard for marine
applications such as ships and oil drilling platforms. It
is listed by UL and approved by FM for releasing
Halon 1301, FM-200 and pie-action or deluge sprinkler
systems. These include foam or water applications.
MXL follows the releasing requirements specified in
the NFPA Standards 12A, 13 and 2001.
Description
The basic MXL control unit consists of the following
subassemblies.- MMB-2 Main Control Board; MPS-6,
MPS-12 Power Supply; MKB-2 Annunciator and Key-
board; MME-3, MLE-6 or MSE-2 Enclosures. Optional
modules which can be installed with the MXL System
include: MOM-2/4 Expansion Card Cage; ALD-21 Analog
Loop Driver; CRM-4 Controllable Relay Module; NIM-
1W Network/Foreign Systems Interface Module; REP-1
Network Repeater Module; XLD-1 "X" Series Loop
Driver; CSM-4 Controllable Signal Module; CZM-4
Conventional Zone Module; PIM-i Peripheral Interface
Driver; CMI-300 CXL Modem Interface Module; PSR-i
Remote Power Supply; MXL-VDT Interactive Video
Display Terminal; NET-4 Style 4 Network Interface;
NET-7 Style 7 Network Interface.
Additionally, the MXL system includes option modules
MOI-7 System Interface, MOD-16 Output Driven and
MID-16 Point Input Module. These can be used to
drive graphic annunciators and Fireman's Smoke
Control Stations or to monitor foreign systems.
The MXL is compatible with a full line of intelligent
initiating devices highlighted by the FirePrint Applica-
tion Specified Detectors, models FP-ii and FPT-ii. It
is also compatible with FireFinder, the NCC series of
text and graphic command centers.
MMB-2 Main Control Board
The function control of the MXL is contained on the
MMB-2 Main Control Board. The MMB-2 controls,
operates and monitors input device identity, network
communications as well as operator commands that
are entered through the MKB annunicator/keyboard. All
operations are supported by either the MPS-6 or the
MPS-12 power supply, eliminating the need for exter-
nal power supplies. The MMB-2 is a direct replace-
ment of the MMB-1 therefore providing total backward
compatibility.
The MMB-2 provides 2 ALD (Analog Loop Driver)
circuits. Each ALD loop can be configured as Style 4
(Class B) or Style 6 (Class A) and can monitor and
control up to 60 Siemens Building Technologies, Fire
Safety Division intelligent input devices and 60 pro-
grammable outputs, either relay, audible or LED. The
MMB-2 is equipped with 2 programmable and codable
Style Y (Class B) or Style Z (Class A) notification
appliance circuits. Each circuit Fire Safety can activate
The MMB-2 includes a built-in battery charger and
transfer circuit. The charger is microprocessor con-
trolled and incorporates a brownout circuit that
switches the system to standby batteries during the
loss and reduction of the primary source AC. Upon
command, the system is capable of displaying the
real time, battery voltage, AC voltage and the charge
current and other power data on the MKB alphanu-
meric display. It also has a 1 amp, 24 VDC output that
powers the CZM-i conventional zone modules.
The MMB-2 is designed with a built-in mounting
bracket. The MMB-2 mounts directly to the MBR-MP
mounting plate for mounting in either the MME-3 or
MME-6 backbox enclosure. The MMB-2 can also be
mounted in the MBR-2 or MBA-i enclosures. MBA-i
requires additional mounting brackets.
The on-board 16 bit microprocessor along with non-
volatile EPROM and Flash memory allow the system
to be custom configured to meet a wide range of
customer requirements. The MMB-2 provides a port
for connection to a laptop computer allowing for off-line
field programming. Complete system configuration
can be easily uploaded, downloaded, edited and
changes verified using CSGM custom programming
software with integrated Compare system software.
Program options include but are not limited to smoke
detector environmental compensation with two
maintenance alert levels, history logging, output
control by event, time based control, detector sensitiv-
ity, alarm verification by device or zone, 32 character
custom alphanumeric messages, system operation
passwords and NAC coding.
MMB-2
MKB-2 Annunciator/Keypad
The MKB-2 mounts on a hinged frame in the MXL
enclosure and provides an 80 character backlit LCD
alphanumeric annunciator which continuously scrolls to
display information concerning system status along
with 32 character user defined device messages.
When multiple events occur, the MKB-2 displays the
last event of the highest priority. Additional data can
be viewed by depressing the NEXT key. At any time,
the display scroll can be stopped by depressing the
HOLD button. Switches are provided for acknowledg-
ing fire alarms, supervisories, security conditions, and
system troubles. An individual switch is also provided
for silencing the system notification appliance circuits.
A separate switch is used for resetting the control
panel.
•
up to 1.5 amps of audible and visual notification
appliances.
A 10 digit numeric keypad is supplied to allow entry of
the user passwords, as well as perform specific menu
driven operation, programming and maintenance
functions. Another series of switches located on The
S MKB-2 allows user access to the TSP-40 Thermal Strip
Printer, when used.
A set of user assignable 'Function" keys provide single
button access to a variety of system commands.
These switches may be used to perform system
operation such as "Drill," manual relay control, zone
disconnect, etc. Contained on the MKB-2 annunciator
are system status indicator LED's which can function
even if the main system microprocessor fails. They
provide indication of Main Power On, Fire Alarm,
Security Condition, System Trouble, Super-visories,
System Audibles Active/Silenced and Partial System
Disable.
The MKB-2 Annunciator communicates with the MMB-
2 Main Control Board through the system network link.
MPS-12
MOM-4 Network Option Module Card Cage
The MOM-4 Card Cage provides the MXL Main Unit or
Remote Units with card slots for option modules. Each
MOM-4 supplies connection space for either two full
width option modules (ALD-21, CZM-4, NIM-113, XLD-1)
or four half width option modules (CSM-4, CRM-4,
CMI-300, NET-7, REP-1) or a combination of one full and
two half width modules.
MPS-6 Power Supply
The MPS-6 is a fully supervised power supply which
provides the system with primary DC power. It is
rated at 6.5 Amps and is unfiltered and unregulated.
It supplies the MXL Control Unit and its expansion
modules with power required for normal operation. The
unit incorporates a circuit breaker on the primary input
and includes a built in AC line filter for surge and noise
suppression. The MPS-6 mounts in the MXL enclosure
backbox.
MOM-2 Network Option Module Card Cage
The MOM-2 provides the MXL main unit, remote units
or MXL small enclosures (MSE-2) with card slots for
optional modules. Each MOM-2 provides space for one
full-width (ALD-21, CZM-4, NIM-1 R) or two half-width
optional modules (CSM-4, CRM-4, CMl-300, NET-7,
REP-11).
-
—T
MOM-2
ALD-21 Analog Loop Driver
The ALD-21 is an MXL Network option module which
supplies two intelligent analog circuits utilizing Fire
Safety "Iv "ILl' and FP series intelligent devices. It
occupies two addresses on the Network and through
the use of a unique communication protocol, devices
connected to the ALD-21 circuits are dynamically
supervised by the MXL control panel. Up to 60
programmable input and output devices may be
connected to each of its two circuits. Each Circuit may
be wired as Class B (Style 4) or Class A (Style 6).
MPS-12 Power Supply
The MPS-12 is a fully supervised power supply which
•
provides the system with preliminary DC power. It is
rated at 12 Amps. and is unfiltered and unregulated.
It supplies the PSR-1, MMB-2 and their expansion
modules with power required for normal operation. The
unit incorporates a resettable circuit breaker on the
primary input and includes abuilt-in AC line filter for
surge and noise suppression. The MPS-12 mounts in
the MXL enclosure backbox.
f nm
=, _____ •r
—:: -
-
£Tz:
ALB-21
CSM-4 Controllable Signal Module
The Controllable Signal Module CSM-4 provides two
fully supervised, programmable notification appliance
circuits. The CSM-4 supplies two Class B (Style Y) or
Class A (Style Z) type output circuits for the supervi-
sion and control of listed audible or visual notification
appliances such as horns, bells, strobes, etc. Each
circuit can provide up to 1.5 amps (24 VDC) of current
to power notification appliances. The CSM-4 is also
used for extinguishing agent releasing (FM-200, Halon,
Pre-Action Sprinkler and Deluge systems). Leased line
and municipal tie connections are also possible with
the CSM-4.
CSM-4
CRM-4 Controllable Relay Module
The Controllable Relay Module CRM-4 is designed to
provide auxiliary control of building functions such as
door holder release, elevator capture, smoke control,
lock release, etc. It provides four fully programmable
relays. Each relay contains one set of SPDT contacts
rated at 2 amps 30 VDC/120 VAC resistive.
CRM-4
CPdll-300 CXL/MXL Interface Module Whe CMl-300 is an MXL option module which provides
oclem communication between an MXL and a CXL
command center. This interface board translates
signals between the MXL network and a CXL and
fully supervises their interconnection.
NET-4 Communication Module
The NET-4 is a plug-in type module used to provide
communication between the Fire Safety MXL and
various other MXL Remote Modules. It is designed
to plug into an edge connector type slot on the PSR-1
Network Supply. The NET-4 provides NFPA Style 4
type communication. This communication is RS-485
operating at 19.2K Baud. The communication is
fully digital.
NET-7 Style 7 Network Interface Card
The NET-7 is a microprocessor controlled MXL network
interface module which allows the wiring of the MXL
RS-485 network in an NFPA Style 7 configuration. The
NET-7 plugs into a half slot of the MOM-2!4 card cage
at the MXL command center (MMB-2) and the PSR-1
or MOM-4 slot at the MXL remote units (MXLR,
MXLRV). The NET-7 provides two independent and
fully supervised communication paths allowing system
operation through an open as well as short circuit. It
also isolates the power supplies at each remote unit
providing the ability to localize ground fault conditions.
The communication operates at 19.2K Baud and is
digital.
NET-7
REP-1 Network Repealer Module
The REP-1 provides the ability to configure the MXLs
local or global networks in a star or daisy chain configu-
ration. The REP-] provides two Style 4 or one Style 7
RS-485 network circuits. Through the use of the REP-1,
the MXL's local network (MXL-MXLR) can
be expanded up to 64 nodes.
MW-i Output/input Module
The M01-7 is an MXL RS-485 Network module which
provides a fully programmable serial interface to the
MOD-16 output drivers and MID-16 input drivers.
When used with the MOD-16's, it provides a serial
annunciator output or relay driver. When used with
MID-16, it provides programmable inputs.
Each M01-7 can operate up to eight MOD-16's and
eight MID-16's simultaneously. Each MOD-16 output
and MID-16 input is independently programmable via
the MXL custom software.
PSR-1 Remote Power Supply
The PSR-1 is a microprocessor controlled remote
power supply and battery charger for use with the Fire
Safety MXL. It operates in conjunction with either an
MPS-6 or MPS-12 to provide 6 or 12 Amps of power
for use with various MXL modules. When used with a
NET-4 or NET-7 plug-in communication module, the
PSR-1 becomes a part of the MXL's internal network. It
acts as an interface between remote option modules
and the MXL.
MOD-16 Output Driver
The MOD-16 is an output driver module used in
conjunction with the M0I-7 as a part of the Fire Safety
MXL System. Up to eight (8) MOD-16s can be con-
nected to an M01-7 interface module. Each MOD-16
provides 16 open collector current sinking outputs
rated at 24 VDC, 50mA. MOD-16 outputs are program-
mable through the MXL custom software.
PIM-1 Peripheral Interface Driver
The PIM-1 is an MXL option module which provides
a bidirectional isolated RS-232 port for connection to
peripheral devices such as printers, CRT's, VDT's,
Color Graphics, Alpha-Numeric Pagers and Remote
Diagnostics Hardware. The PIM-1 mounts in the MXL
Enclosure. It connects to the MMB-2 and provides
a screw terminal block for connection of RS-232. A
number of supervised and non-supervised formats
are available.
MID-16 Programmable Input Driver
The MID-16 is an input module used in conjunction
with the M0I-7 as a part of the Fire Safety MXL
System. Up to eight MID-16s can be connected to a
single M01-7 along with eight MOD-16 output driver
modules. Each MID-16 provides a non-supervised
input which can monitor normally open contact de-
vices. Each individual MID-16 input can be separately
used as a part of the MXL custom programming logic.
These inputs can be individually set for either Alarm,
Supervisory, Trouble, Security or Status usage. They
can also be configured to provide supervision for
lamps driven by MOD-16 outputs. Screw terminals
and connectors are provided on the MID-16 modules
for interface to monitored devices.
S
MME-3 MXL/V Standard Size Enclosure
The MME-3 enclosure set Consists of a sheetmetal
backbox and door with keylock. The MME-3 can be
used for either the MXL System, MXLV Voice Com-
mand Console, MXLR Transponder, MXLRV Voice
Transponder or Amplifier Equipment (using the MSR-1
Rail Kit). To mount MXL/MXLV modules in the MME-3,
the MBR-MP removable module mounting plate is
required. Using the MBR-MP mounting plate (1) MMB
or (1) PSR-1 and up to 3 expansion cardcages (MOM or
0MM) can be mounted in the MME-3 enclosure. When
used to mount MXL amplifiers (EL-410), the MBR-MP
is not required, instead up to (3) EL-410 amplifiers may
be installed in the MME-3 by using (3) MSR-1 Rail Kits.
When amplifiers are mounted in any enclosure always
install MDG-1 grills in the door for proper ventilation.
MME-3 is designed for surface of semi-flush mounting
and includes various knockouts for wire and conduit
entry. The door in the MME-3 set has two cutouts for
either blear lenses, blank plates or grills depending on
the application, and contains a key lock.
MBR-MP MME-3 and MLE-6 MXL
Module Mounting Plate
The MBR-MP MXLN Module Mounting Plate is
required for use in both MME-3 and MLE-6 enclosures
to mount all MXL and MXLV equipment. MBR-MP is
not necessary if the MME-3 and MLE-6 enclosures are
to be used only for mounting of amplifiers (EL-410).
MBR-MP mounting plate bolts to either the MME-3 or
MLE-6 enclosures for easy installation on the job site.
The MBR-MP also has handles to allow easy transport
and mounting. The MBR-MP contains mounting studs
for (1) MMB or PSR-1, (1) PiM-1, (1) TBM-2, and up to
(3) MOM or 0MM cardcages or 2 cardcages and (1)
TSP-40 Printer (same mounting studs as the MBR-2
enólosures).
The MBR-MP is ordered and shipped separately from
the MME-3 and MLE-6 enclosures.
MLE-6 MXL/V Large Size Enclosure
The MLE-6 enclosure set consists of a sheetmetal
backbox and door with two key locks. The MLE-6 can
be used for either the MXL system, MXLV Voice
Command Console, MXLR Transponder, MXLRV Voice
Transponder or Amplifier Equipment (using the MSR-1
Rail Kit. To mount MXLN modules in the MLE-6, the
MBR-MP removable module mounting plate is re-
quired with the MBR-3MP optionally available for use.
Using the MBR-MP mounting plate (1) MMB or PSR-1
and up to (3) expansion cardcages (MOM or 0MM) can
be mounted in the MLE-6. If additional cardcages are
required, the MBR-3MP optional cardcage mounting
plate can also be installed in the MLE-6 below the
MBA-MR The MBR-3MP allows mounting of an addi-
tional (3) MOM or 0MM module expansion cardcages.
Various combinations of hardware can be installed in
the MLE-6. If only amplifiers are to be installed in the
MLE-6, no MBR-MP or MBR-3MP plaies are required.
Instead up to (5) EL-410 amplifiers can be installed by
using (5) MSR-1 rail kits. The MLE-6 can also be used
to mount up to (3) MXL cardcages and (2) amplifiers.
This configuration would be typical of a remote voice
transponder cabinet. In this configuration (1) MBR-MP
would be used in the upper half of the MLE-6 to
mount the MXL modules, while the lower half would
use (2) MSR-1 rail kits to mount up to (2) EL-410
amplifiers.
The MLE-6 is designed for surface or semi-flush
mounting and includes various knockouts for wire and
conduit entry. The door supplied with the MLE-6 set
has (3) cutouts for either clear lenses, blank plates or
grills, depending on the application. The door also
contains (2) key locks --keyed the same. Various
combinations of dead front mounting plates are
possible with the MLE-6 enclosure. A typical MXLV
installation would have (1) MKB-2 at the top, and (2)
MHD-3 dead front plates in the middle (for (14) VSM/
VLMNFM modules per plate) and (1) or (2) MHD-2
lower dead front plates.
The MBR-MP is a removable MXLN module mounting
plate that allows the enclosure MME-3 or MLE-6 to be .hipped to the job site for installation of wiring and
onduit, while the system hardware (electronics) is
mounted to the studs on the MBR-M pre-wired,
programmed and tested prior to delivery and installa-
tion at the job site. This allows for quicker, more
efficient system start ups with less chance of the
sensitive electronics being damaged while field wiring
and conduit are connected to the system enclosure.
S
MHO-1 Upper or Middle Dead Front Panel
The MHD-1 is a hinged sheet metal panel which
attaches to either the MME-3 or the MLE-6 enclosure
backbox. It fits in either the upper or the middle section
of the MME-3 backbox or the upper or either of the two
middle sections of the MLE-6 backbox. It has an opening
with a cover plate for the TSP-40 printer when used and
attaches to the backboxes with screw fasteners. When
in place it covers and protects modules and wiring,
providing dead front construction in that area.
- MLIE-6
MBR-3MP MLE-6 Optional Cardcage Mounting Plate
The MBR-3MP is an optional MXL/MXLV cardcage
mounting plate for use exclusively in the MLE-6
enclosure. When installed in the MLE-6 backbox,
the MBR-3MP adds the option of mounting up to an
additional (3) MOM or 0MM expansion cardcages.
MDL-1 Clear Lens
The MDL-1 is a clear Plexiglas' lens which fits in either
one of the two openings in the MME-3 enclosure door
or in one of the three openings in the MLE-6 enclosure
door. One lens is included in the MDL-1 package.
MDL- 1
MOB-11 Sheet Metal Blank Plate
The MDB-1 is a sheet metal blank plate which fits in
either one of the two openings in the MME-3 enclo-
sure door or in one of the three openings in the MLE-6
enclosure door. One blank plate is in the MDB-1
package.
MHO-2 Lower Dead Front Panel
The MHD-2 is a hinged sheet metal panel which
attaches to either the MME-3 or the MLE-6 backboxes.
It mounts in the lower section on the MME-3 and on
the lower two sections of the MLE-6 backbox. It has
no openings and attaches to the enclosures with screw
fasteners. When in place, it covers and protects
modules and wiring, providing dead front construction
in that area.
MHO-3 Middle Dead Front Plate for Mounting
Switch/LED/Fan Control Modules
The MHD-3 is a hinged sheet metal panel that attaches
to the MME-3 or MLE-6 backboxes. It fits in either the
middle or the upper sections of these enclosures. It has
openings for two rows of VSM-1 Switch Modules, VLM-1
LED Annunciator Modules, VFM-1 Fan Control Modules
orVSB-1 Blank Plates. Each row can mount up to (7)
modules for a total of (14) modules per MHD-3. The
MHD-3 attaches to the backboxes with screw fasteners.
It is hinged for easy access to the rear of the modules
and inside of the enclosure.
S
MOB-1
S
MHO-4 Middle Dead Front Plate for the Switch/LED/
Fan control Modules with Printer Cutout
The MHD-4 is a hinged sheet metal panel that attaches
to the MME-3 or the MLE-6 backboxes. It fits in the
middle section of both enclosures. It has two rows for
mounting of VSM-1 Switch Modules, \/LM-1 LED
Annunciator Modules, VFM-1 Fan Control Modules or
'JSB-1 Blank Modules. Each row has space to mount
(4) modules, for a total of (8) modules per MHD-4 The
MHD-4 also has a Cutout to display the TSP-40 Internal
Thermal Strip Printer. The MHD-4 mounts to the
backboxes with screw fasteners. It is hinged for easy
access to the rear of the modules and inside of the
enclosure. When in place, it covers and protects
modules and wiring, providing dead front construction
in that area.
HO-
MSR-1 Rail Kit
The MSR-1 is a System 3 type rail kit which fits into
either the MME-3 or the MLE-6 enclosures. The MSR-1
MSE-2 MXL Small Enclosure
The MSE-2 is a small MXL enclosure capable of
housing an MMB-2 or PSR-1 and MPS-6 or MPS-12.
When expansion is required the MSE-2 provides for
mounting of either one (1) MOM-2 or OMM-2. MSE-2
is part of the MXL-SS and MXLV-SS packages.
MS E -2
MXL-VDT Interactive Video Display Terminal
The MXL-VDT is a 14" amber monitor with detachable
keyboard. It provides an interactive terminal for
secondary display of MXL information, and operation
of MXL functions such as Acknowledge, Silence and
Reset, as well as arming and disarming devices. It also
provides a means for generating system reports such
as listing smoke detector sensitivity settings and
voltages, battery and power supply voltages and
current, and displaying the event log. A printer may
be connected to the MXL-VDT
MXL-VDT
TSP-40 Thermal Strip Printer
The TSP-40 is a thermal strip printer designed for use
with the Fire Safety MXL system. It mounts in the
MXL enclosure and its printout is visible through a
window in the locked enclosure door. Printouts are
automatically spooled on a take-up reel for easy
record storage.
.comes with a U-bracket and a Z-bracket. It allows
modules such as the EL-410 amplifier, PS-35 Power
Supply, BC-35 Battery Charger,MOI-7 I/O Interface,
MID-16 Input Driver, MOD-16 Output Driver, PS-5A
Power Supply, SYS3-MPFO for mounting the D2300CP
Fiber Optic Interface modules or the CCU Pager
interface, or any other System 3 type module required
to be mounted in the MME-3 or the MLE-6 enclosures.
When used in the MME-3 enclosure (3) MSR-1 Rail
Kits can be installed to mount up to three rows for up
to (3) EL-410 amplifiers. When used in the MLE-6, up
to (5) MSR-1 Rail Kit rows can be installed to allow
mounting up to (5) EL-410 amplifiers. When the MLE-6
enclosure is used with the MBR-MP mounting plate to
install MXL or MXLV equipment, up to (2) MSR-1 Rail
Kit rows can also be installed in the MLE-6 for mount-
ing of either (2) EL-410 amplifiers or some complement
of System 3 type mount modules.
S MSR-1 TSP-40
S
CC-i Remote Command Console
The RCC-i is a remotely located MXL annunciator
display module. The RCC-i contains an 80 character
LCD display and control keypad (MKB) and a PS-51\17
network interface. RCC-1 s can be located anywhere
that control or annunciation is required. RCC-i can be
programmed for display only or can provide display
and system control. If a PlM-1 is added to the RCC-1,
remote printers, VDT or graphics computers can be
located throughout a facility.
RCC-1
PIM-2 Parallel Printer Interface
The PlM-2 is an MXL or CXL parallel printer interface
module. PlM-2 connects to PlM-i to allow MXL
connection and supervision of any EDP UL listed
printer.
PAL-1 UL Listed Parallel Printer
The PAL-1 is a UL listed supervised parallel system
printer for MXL or CXL. The PAL-1 connects to the PlM-2
and PlM-i to provide MXL with a UL listed parallel
printer that is supervised.
ICP-36 Intelligent Control Point
The ICP is a field mounted output module capable of
being programmed to be either a remote bell or horn,
speaker or telephone zone. The ICP communicates with
the MXL via the ALD loop.
lcP
LlM-1 Line Isolator Module
The LlM-i is a short circuit isolator module for use
on the MXLs analog loops. The LlM-i is capable of
providing Style 4 or Style 6 wiring of ALD loops.
Multiple short circuit isolators can be used on a single
ALD loop to prevent loss of protection in the event of
a short circuit.
LIM-1
PS-5N7 5 Volt Power Supply/Network Interface
The PS-51\17 is a 5V power supply and MXL local
network interface module. The PS-5N7 is an integral
part of the RCC-i. The PS-51\17 can be used to provide
a Style 4or Style 7 network interface for either a
remote transponder for MXLV with either T8 M-2, ACM-
1 and VSM-1NLM-1NFM-1 or to drive 0MM-1 and
associated MXLV cards.
PS-5A 5 Volt Power Supply
The PS-5A provides 5 Volts for powering the M0I-7 It
obtains its power from the 24-volt supply in the MXL
system. Both the M0I-7 and the PS-5A mount on
system 3 rails. They can also be mounted external to
the MXL control. They typically drive remote graphic
annunciators or monitor foreign systems and devices.
ROM-MXL, ROM-PC
The RDM-MXL in combination with the RDM-PC
provides the ability to call up an MXL system to
check on the system status. The RDM-PC connects
a remote computer to the MXL equipped with the
RDM-MXL. The RDM-PC initiates a call to the MXLs
RDM-MXL module. The RDM-MXL answers the call.
The RDM-PC identifies itself with the login name.
As a built-in security measure, when the login name
is recognized by the RDM-MXL, it then hangs up and
initiates a call back to verify the login and password.
Once the login and password is verified, the operator
is on-line with the MXL. The operator can list system
status, alarms, troubles, supervisories, and/or security
events I
NlM-W Network Interface Module
The NIM-IW allows the interconnection or networking
of up to 63 MXL systems. The NlM-1VV provides an
RS-485 communication path in either Style 4 or Style
S 7 wiring configurations. The NIM-1W allows MXLs to
have interpanel logic and communicate in a peer to
peer fashion. The NIM-1W can be programmed via
CSGM logic as a Foreign System Interface to commu-
nicate with external building management systems.
RW
-3 .... m c:& -
I
£ ••iI
NIM-1W
FireFinder NCC-G - Network Color Graphics
FireFinder is a PC based color graphics command
center designed for use with the LifeLlNK network and
provides full control and annunciation for a LifeLlNK
network of up to 63 MXL-IQ or MXL systems. The
NCC-G is used to monitor and control alarms, troubles,
security, supervisory and all system events from one
of many MXL series systems. The NCC-G maintains an
extensive history log of all system events and has
S extensive report generation capabilities. User program-
mable function buttons allow site specific control
functions. Multiple NCC-Gs may be connected to a
LifeLINK network. PC ordered separately. The model
NCC-GL is a color graphics command center for a
single, stand-alone MXL system. It has all of the
features of the NCC-G.
FireFinder NCC-G
CCU/M Alphanumeric Pager Interface
The CCU/M is a ancillary module that connects to the
PlM-1 to transmit MXL status information in text
message format to an alphanumeric pocket pager. The
CCU/M can be connected to an existing phone line and
can dial out to a pager using its onboard modem to
transmit information via a paging service. The CCU/M
can also connect directly to an existing on-site paging
S system. Through programming the CCU/M can send
different types of events to different pagers. Up to 8
different messages can be sent to pagers directly
from the CCU/M. Alarms, Troubles, Supervisory,
Security, Arm/Disarm, Status Points, Audible Status,
and Reset can be directed to all or only certain alpha-
numeric pocket pagers.
Model
Number Description
Part
Number
CZM-1 Conventional Zone Module 315-090721
ILi-i/1HI1A/IAH Intelligent Ion Detectors 315-09272'
ILP.1/IPLT-1 Intelligent Photo Detectors 315-09259'
JLT-1 Intelligent Heat Detectors 359333
iLI-1 B/i BH Intelligent Ion High Vei 315-093234
ILP-2 FirePrint Application
Specific Detection
315-095023
MSI-I08/208 Intelligent Manual Station 315-093329
MS-MI Intelligent Metal Manual Station 315-092169
TRl-86/360/1361`1 Intelligent Monitor Module
single/dual_and with array)
315-093315
TRl-86M Intelligent Mini-Monitoring Module 315-094547
ICP Intelligent Control Point 315-092471
LIM-1 Line Isolator Module 315-092135
FP- 11 Intelligent FireprinrM Detector 315-095921
jlRl-S/D/R Intelligent Monitor Module 315-096242
For further details refer to MXL Manual P/N 315-092036
MMB-2
Electrical Specifications for Analog Loop Devices (T82. 1-4 and T3, 1-4)
1. Electrical Ratings:
Supervisory: 24VDC peak, 105mA max.
Alarm: 24 VDC peak, 105mA max.
(60 devices in alarm)
All wiring must be in accordance with Article 760 of
NEC or local building codes.
Only Cerberus Pyrotronics devices may be used.
(See Table 1)
A maximum of 60 devices in any combination may
be connected to a single analog loop.
No end of line device required.
Both circuits are power limited to NFPA 70/NEC.
Each detector or group of detectors, requires a two
wire circuit of minimum 18 AWG thermoplastic
fixture wire enclosed in a conduit or minimum 18
AWG limited energy shielded cable without
conduit, if permitted by local codes.
Total circuit resistance must not exceed 100 ohms.
Maximum capacitance:
0.4pF between + loop and - loop
0.8pF between + loop and chassis
0.8pF between - loop and chassis
7 T-tapping is not allowed on Class A (Style 6) loops
0 MMB-2 CZM-1 Power
AUX power is available on TB5 terminals 9-12
All wiring must be in accordance with Article 760 of
NEC or local building codes.
AUX power is power limited to NFPA 70/NEC 760.
Electrical Ratings: 18-31 VDC, 1A max.
MMB-2 Notification Appliance Circuits
(TB5, 1-4 and TB5, 5-8)
These notification appliance circuits are for alarm
notification appliances only (NFPA 72 Local). For
Municipal tie (NFPA 72, Chapter 4 ) or Leased Line
(NFPA 72, Chapter 4), use model CSM-4.
All wiring must be in accordance with Article 760 of
NEC or local building codes.
Both notification appliance circuits are power
limited to NFPA 70/NEC 760.
Electrical Ratings:
Supervisory 18-31 VDC, 12mA max
Alarm 18-31 VDC, 1.5A max.
0 5, End of Line Device: EOL 2.2K, 1/2VV
(P/N 140-820380)
6. Line Resistance: Not to exceed 3 ohms max
For compatible notification appliances see 315-096363
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
S LiSTING SERVICE
LISTING No. 7170-0067:154 Page 1 of 1
2 CATEGORY: Control Unit (High-Rise)
LISTEE: Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Model MXL and MXL-IQ fire alarm control units. Coded or noncoded; local, auxiliary, remote and
central station proprietary service; automatic, manual waterfiow, releasing service and sprinkler
supervisory service when used as a remote station (protected premise) unit or proprietary fire
receiving unit. Refer to listee's data sheet for additional detailed product description and
operational considerations. Basic components:
MMB-1 1, *21
, *-3'/ SMB-12, 22, *..32 Main Control Board
M KB- 1', 21, .42 *1 *..62 Keyboard/Annunciator Panel
MPS-6, -12 Power Supply
CRM-4 Relay Module
CSM-4 Signal Module
CZM-4 Conventional Zone Module
BTX-1, BP-61 Battery Set Module
MSE-21, ..32, *..3M2 Enclosure *MSE3MD Enclosure Door
Silent Knight 5128, 5129 Dialer/DACT (Listing No. 7300-0559:120)
- For use with Model MXL only. . 2
- For use with Model MXL-IQ only.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and
in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating, and UL label.
APPROVAL: Listed as fire alarm control units for high rise application when used in conjunction with listee's listed
Model VoiceCom system (CSFM Listing No. 6911-0067:173) and separately listed compatible
initiating and indicating devices. See (CSFM Listing No. 7300-0067:172) for optional control unit
accessories. Refer to listee's Installation Instructions Manual for details.
*These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition.
Rev. 01-02-2005
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. .Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
Fire Safety
[IJ RCC=3/3F
MXL/MXLV Remote Annunciator/Keyboard
w/Enhanced Display
ENGINEER AND ARCHITECT SPECIFICATIONS
[1
Remote MKB for Display and Control
Full Command Keyboard
6" LCD Display
Automatic Backlight
Displays 8 Events and System Status
Programmable Function Keys
Partial System Disable LED
Power LED
Alarm, Supervisory, Trouble And Security LED's
Audibles Active/Silenced LED with Local Audible
Menu Driven Operator Commands
User Help Screens
Printer Control Keys
Display Control Keys
Tactile Membrane Switches With Audible Feedback
Metal Enclosure with Key lock Door
Restricts Keypad Access
@ ULC Listed
Description
The RCC-3 is a full control remote display/keyboard
center for use with the Siemens Fire Safety MXL and
MXLV systems.The RCC-3 includes its own enclosure
with a lockable door. It provides a complete operator
interface including a 6" ¼-VGA backlit LCD for display of
all system information.The LCD shows up to eight
events in sequential order by priority and includes event
type, the custom message for the event, and an indica-
tion If the event has been acknowledged. Up and down
arrow keys allow the user to scroll through the list of
events, and a separate key will display more information
about the highlighted event, including device type and
location and the time of the event. The display will also
give a system status line, indicating how many of each
type of event is present on the system.
The RCC-3 provides a set of keypads used to execute
system commands such as Acknowledge, Silence,
S Reset as well as disarming of devices for maintenance
and generation of system diagnostic reports. From the
keypad the operator is able to change the sensitivity
setting of smoke detectors, check device voltages, obtain
system power reports, disarm input and output devices
and manually toggle remote and local relays. All com-
mands are menu driven and a Help key allows the
operator to get further explanation of the command
structure. Operator actions are prompted so training is
kept to a minimum.
The RCC-3 also provides a set of 12 programmable
functions keys.The keys can be configured to activate
functions such as Drill, Fan Shutdown, Door Release, etc.
LEDs on the RCC-3 in conjunction with a local audible
signal, indicate active conditions such as Alarm, Supervi-
sory, Trouble and Security. The LEDs flash and the audible
sounds until events are acknowledged. Additional LEDs
indicate Audibles Silenced, Power On and Partial System
Disable.The Partial System Disable LED illuminates
whenever an input or output device is disarmed.
CATALOG NUMBER 5078
Multiple RCC-3s can be used in the system each provid- ing full control of the MXL system. Up to four multiline
displays (MKB-5, MKB-6, or RCC-3) can operate in a fully
supervised mode, each with independent printer driver
capability built-in.
The RCC-3 keypad and display are covered by a clear lens
as a part of the enclosure's lockable door.
This equipment is approved for operation over the
temperature range of 0°C to 49°C.
Ordering Information
Model
Number Description Part Number
Rcc-3 Fd cipia 5QC-64535
RCC-3F e.rno.e C.mmeti Cr1ar ,/ Eh.oced Cip(v
1 70tiflt
500-E4259S
RCC-3C. IRC. w.,Eianted ispIs lfrenthiEnglishi 5t3C-B4657
RCC-3FC
j
Fcc - Ecared Dica' lFrenchEnJish.
1L!.5t1 t!t8I.MtI
500-648985
S
S
Siemens,Buflding Technologies
Fire Safety
Fire Safety
8 Fernwood Road
Fiorhan, Park, NJ 07932
Tel: (973) 593-2600
FAX: (973) 593-6670
Websice wwwsbt.siernens.com/fis
ff103
SM
SFS-IG
Printed in U.S.A.
Fire Safety
2 Kenview Boulevard
Brampton, Ontario
Canada L61 5E4
Tel: (906) 799-9937
FAX. (905) 799-9858
November2003
Ne IS5L9
LISTING No.
CATEGORY
LISTEE:
DESIGN:
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
USTING SERVICE
7300-0067:152 Page 1 of 1
Misc. Devices/Control Unit Accessories
Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
Control unit accessories as listed below. Refer to listee's data sheet and control unit's
installation instructions for additional detailed product description and operational
considerations.
S
PSR-1
NET-4, -7, -7M
M0I-1/M0I-7
MOD-16
VCP-25
FT-30 1/C/CL, FT-302/C/CL
FJ-303, P1-303, -304,
FJ-303SS, -304, -304SS
CP-2297
CP-2341
PAL-1
MID-16
VDT
ICP, ICP-B6
PIM-2, RSE-1
RCC-1, RCC-1F, RCC-2, *RCC..3 *RCC..3F
CP 7537-394
CP 7554-001, CP-7574, CP-75741
SCD-19M, -191M, SCD-21M, -21TM
MXL-G/CXL-G
CPP
LLM-1
CP-7585-33/-66/-1 00/-P 133
SCD-550, -5501, -550-DOS
AIC-4Z, NCC-1F
Remote Power Supply
Communications Interface
Voice and Annunciator Driver
Output Driver
Remote Indicating Device Zone Output Module
Remote Telephone Station
Remote Telephone Station
Remote Telephone Station
Signal Line Suppressor
Supply Line Suppressor
Printer
Input Module
Video Display Terminal
Intelligent Control Point Module
Printer Interface Module
Remote Command Center
Computer
Monitor
Monitor
Graphic Interface
Multiplexer
Leased Line Module
Computer
Computer
Interface Card
INSTALLATION:
MARKING:
APPROVAL
In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
Listee's name, model number, electrical rating, and UL label.
Listed as control unit accessories for use with listee's separately listed compatible fire alarm
control units. Refer to listee's Installation Instruction Manual for details.
Rev. 10-28-2004
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
(\ and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.
v' Refer to listee's data sheet, installation instructions and/or other suitable information sources.
S
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
Series PS-12/24-8CP
Series PS-I 2/24-8MP
:- wneoc;'c
AD\ El S J
Helping People Take Actl•onSM
Description
POWERPATHTM Series PS-12/24-8CP and PS-12/24-8MP are
power limited 8 amp power supply/chargers used to expand
the supervised power capability of a fire alarm control panel
(FACP) for notification appliance circuits (NAC).
The PS-12/24-8CP provides up to 200 milliamps of continuous
auxiliary output that can be used for control functions during
alarm (or up to 60 milliamps for 60 hour battery requirements).
The PS-12/24-8MP provides up to 3.5 amps of auxiliary output
that is available only during nonalarm condition for such
applications as door holder systems.
Both models provide regulated and filtered 12 or 24 VDC output
to four (4) Class "B" or two (2) Class "A' circuits. Each Class "B'
circuit has a rating of three (3) amps with a total output of up to
eight (8) amps. Each Class "A" circuit is rated at three (3) amps.
Two (2) Class "A" or Class "B" inputs from an FACP and two (2)
dry contact inputs are provided to trigger the outputs. The units
accept either 12 or 24 VDC inputs and provide 12 or 24 VDC
outputs. Both units support a full 8 amps of notification power
even if the battery is in a degraded mode and only AC power is
connected.
POWERPATH Series PS-12/24-8CP and PS-12/24-8MP are compatible with all Wheelock 12 or 24 VDC Life Safety Notification
Appliances and with their Patented BUILT-IN SYNCHRONIZED
MODE feature, they can control and operate all of Wheelock's
Synchronized Notification Appliances, including silencing
audibles while maintaining strobe activation.
POWERPATH TM
NAC POWER SUPPLIES
(Batteries Not Included)
S
Features
Approvals
Approvals Include: UL Standard 864, California State Fire
Marshal (CSFM), (New York City (MEA), Factory Mutual
(FM), Chicago (BFP) See Approvals by model in
Specification and Ordering Information
Compliant with NFPA 72
Inputs
Compatible with 12 or 24 VDC FACP
115 VAC @50/60 Hz or 240 VAC @50/60 Hz
Two 12 or 24VDC NAC Initiating Circuits from host panel
Two "Dry" contact input circuits
Accepts 2 Class "A" or 2 Class "B" NAC circuit inputs
Additional activation options are: NC contacts or open
collector of a transistor
Outputs
8 amperes rated supply current @ 12 or 24 VDC
Filtered and regulated power supply outputs
Class 2 rated power limited outputs
- Dip switch selectable options
Field selectable 12 or 24 VDC outputs
4 Class "B" or 2 Class "A" or 1 Class "A" and 2 Class
"B" Notification Appliance Circuits)
Each Class "B" output has a maximum rating of three
(3) amperes
- Each Class "A" output has a maximum rating of
three (3) amperes
Code 3 (Temporal) option
Steady output option
Copyright 2004 Wheelock, Inc. All rights reserved.
Outputs Cont.
Built-In Wheelock Synchronization Protocol
Input and output synchronization (including pass
through)
Supervision
FACP NAC supervision steered to either input #1 or #2
Common input and output trouble circuit
Input and output LED indicators
AC fail supervision (Form "C" contacts rated @ 1 amp
24 VDC or 115 VAC)
Battery presence and low battery supervision (Form
"C" contacts rated @ 1 amp @ 24 VDC or 115 VAC)
Ground fault detection
4 latching LED's for NAC trouble annunciation
Power
Not Battery Dependent - Full 8A even if battery is
degraded
Automatic switch over to standby batteries when AC
fails
Supports sealed lead acid or gel type batteries
Fused battery protection
Thermal and short circuit protection with auto reset
Supports both TAH or I2AH batteries in the same
cabinet (Cabinet Size: 16" H x 12.25" W x 5" D)
Auxiliary Power
Up to 200 mA continuous with PS-12/24-8CP
Up to 3.5 amps nonalarm with PS-12/24-8MP
Normal Mode (Class B)
OUT I
IN 0 Ui- S NC
- WHEELOCKSYSOT
IEMPORXL
• F
INn INPUT SELECT -
IC NEXT APPLI NCE OUT
OR EOLFR=- REIn -
C POWERPk
OUTJ
sWg -
OUT
TO NEXT APPLIANCE
OR EOLR
(2.2K OHMS)
TO NEXT APPLIANCE
OR EOLR
(2.2K OHMS)
TO NEXT APPLIANCE
OR EOLR
(2.2K OHMS)
TO NEXT APPLIANCE
OR EOLR
(2.2K OHMS)
Normal Mode (Class A)
0 U T 1-4 + IN OUT SYNC OUTi
Ni =10- WHEELOCK SYNC - - TEMPORAL
TO NEXT APPLIA CE INPUT SELECT
F OR EOLR OR RETU _____ RET1 _
TO FACP OUTI_____
(CLASS A) -_____
POWERPA H C
OUTj
S
0UT___
I,, S
POWERPATHTM Operating Modes (refer to Installation Manual):
Normal Mode: Provides constant 12 VDC or 24 VDC output upon initiation by a
voltage to input IN or 1N2 or by a contact opening on DRY1 or DRY2. The unit returns
to standby mode when the input is deactivated.
Wheelock Sync Mode: Provides signals for synchronization of patented Wheelock
audible and strobe notification appliances. Audibles can also be silenced in this mode
while the strobes continue to flash.
ln>Out Sync Mode: Accepts a coded signal or synchronization signal on the input to
provide a coded output or synchronized output. This signal may come from a FACP,
another POWERPATH or a Wheelock SM or DSM synchronization module. Caution:
Do not use strobes on coded output circuits.
Temporal Mode: Codes the output voltage in a code-3 temporal pattern to drive audible
appliances such as horns, bells or chimes. Caution: Do not use strobes on coded
output circuits.
S
0
S
S
Architects and Engineers Specifications
The power supplies shall be Wheelock POWERPATH Series PS-12/24-8CP or PS-i 2124-8MP, or equivalent. The units shall be stand alone power supplies intended for powering fire alarm notification appliances via their own Notification Appli
a
n
c
e
C
i
r
c
u
i
t
(
s
)
(NAC). The units shall be UL 864 Listed for power limited operation of their outputs and comply with NFPA 70 (NEC), article 760
The power supplies shall support a full 8A of notification power even if the battery is in a degraded mode and onl
y
A
C
p
o
w
e
r
is connected.
The power supplies shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (
F
A
C
P
)
or a "Dry contact' closure. The units shall be 8 ampere, 12 0r24 VDC, regulated and filtered, supervised remote power s
u
p
p
l
y
!
chargers. The power supplies shall provide a full 8 amperes of current and shall not be battery dependent. They shall o
p
e
r
a
t
e
over the voltage range of 8 to 33 VDC or FWR. The primary application of the units shall be to expand fire alarm syst
e
m
capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support
system accessories or functions. The power supplies shall provide four Class "B", two Class "A', or two Class "B" and one Class "A"
N
A
C
c
i
r
c
u
i
t
(
s
)
.
The PS-12/24-8CP units shall also supply up to 200 mA of auxiliary power that is available during both nonalarm a
n
d
a
l
a
r
m
.
The PS-12/24-8MP units shall also supply auxiliary power of not less than 3.5A at 24 VDC during nonalarm. The po
w
e
r
supplies shall be capable of charging batteries of up to 12 ampere hours per NFPA 72 (1999). Input activation options shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed
t
o
a
n
y
combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 3 amperes for Class "B" applications or 3 amperes each for Class "A". The outputs shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The power supplies shall provide independent loop supervision for eith
e
r
C
l
a
s
s
"
A
"
o
r
Class "B" FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incomi
n
g
N
A
C
circuit. The units shall have common output terminals. The power supplies shall be powered from a 120 VAC or 240
V
A
C
source with a current consumption of 5 amperes max. The unit shall incorporate short circuit protection with aut
o
r
e
s
e
t
.
T
h
e
power supply shall incorporate a built in battery charger for lead acid or gel type batteries with automatic switchover to batt
e
r
y
b
a
c
k
up in the event of AC power failure. The charger shall incorporate fused protection for the batteries and have the ability to repo
r
t
low battery and/or no battery condition(s). Standby current for battery back up shall be 100
mA max. The cabinet dimensions shall be 16!'H x 12.25" W x 5" D.
A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING S
P
E
C
I
F
Y
I
N
G
O
R
A
P
P
L
Y
I
N
G
THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT
I
N
I
M
P
R
O
P
E
R
A
P
P
L
I
C
A
T
I
O
N
,
INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROP
E
R
T
Y
D
A
M
A
G
E
,
A
N
D
SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
Specifications and Ordering Information
Model Number Order Code Input Voltage/Current Approvals
I UL MEA J CSFM FM I
PS-12/24-8CP 3047 120/220 VAC @ 50/60 Hz: 5.0 amps max. X * X *
PS-12/24-8MP 3046 120/220 VAC @ 50/60 Hz: 5.0 amps max. X X J I X
Output NAC Circuits Output Voltage/Current
XApproved
Pending
I
Aux Output
PS-12/24-BCP
200 mA
60 mA
200 mA
60 mA
Four (4) Class "B' 12/24 VDC @ 3 amps per Circuit
Two (2) Class "A" or 12/24 VDC @ 3 amps per Circuit
One (1) Class "A" and Two (2) Class "B" 12/24 VDC @ 3 amps per Circuit (Class "A")
12/24 VDC @ 3 amps per Circuit (Class "B")
Standby Current 0.060 Amps 1
urrent I Alarm Current I 0.100 Amps
Total NAC Current 8 Amps Max.
Standby Batteries Standby I
Time
Alarm Output Aux Output
Total Amps/Minutes PS-12124-8MP H
24 VDC/12 AH
(uses two (2) 12 voc batteries in series)
24 Hours 8 Amps/i 5 Minutes
8 Amps/15 Minutes
, 3 5A dung
8 Amps/15 Minutes non alarm
8 Amps/iS Minutes .
60 Hours
12VDC/12AH 24 Hours
60 Hours
NOTE: Due to continuous development of our products, specifications and offerings are subject to
c
h
a
n
g
e
w
i
t
h
o
u
t
n
o
t
i
c
e
in accordance with Wheelock Inc. standard terms and conditions.
WE ENCOURAGE AND SUPPORT NICET CERTIFICATION
3 YEAR WARRANTY
National Sales Office Made in USA
800-631-2148
Canada 800-397-5777
E-Mail: lnfo@wheelockinc.com . .NXERUAN
Distributed By:
S900011/04 273 BranchportAveriue Long Branch, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
USJ1NG SERVICE O LISTING No. 7315-0785:162 Page 1 of 1
CATEGORY: Power Units
LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch, NJ 07740
Contact: *Brian Lampe (800) 631-2148 x6389 FAX (732) 222-5607
DESIGN: Model. PS-12/24-8MP, PS-12/24-8CP, *ps..24.8Mc Indicating Circuit Power Supply. Unit
is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded
power driving capability of up to four notification appliance circuits (NAC). Units may be
connected to any 12VDC or 24VDC fire alarm control panel. The unit is intended for use
with listee's Model MPEOL end-of-line resistor. Replacement printed circuit board
assembly part number PSX-12/24-8MP, PSX-12/24-8CP and *psx..24..8Mc Model PS- 4CA Class A Card for use with Model PS-24-8MC. Refer to listee's data sheet for
additional detailed product description and operational considerations.
RATING: 120/240 VAC, 50/601-1z input; 12 or 24 VDC output
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and
in a manner acceptable to the authority having jurisdiction
MARKING: Listee's name, model number, electrical rating, and UL label.
APPROVAL: Listed as a power supply unit for use with separately listed compatible fire alarm control units.
Refer to listee's Installation Instruction Manual for details.
NOTE: For fire alarm use, the secondary (standby) power supply shall supply energy during power
loss to operate a protected premises, central station, or proprietary system for 24 hours or an
auxiliary or remote station system for 60 hours in the normal condition, followed by not less
than 5 minutes of alarm as required by code. Two 12V batteries are required for 24V
operation, one 12V battery is required for 12V operation.
Rev. 06-23-2006
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
... . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
bate Issued: JUNE 23, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
Heonci eop1e Take .ct"on
Wi.'4OC
-
SERIES RSS & RSSP SINGLE
& MULTI-CANDELA STROBES
& STROBE PLATES
S
DESCRIPTION
Wheelock's patented Series RSS Strobe Appliances
and Series RSSP Strobe Plates have lower current draw
while maintaining outstanding performance, reliability
and cost effectiveness. These versatile appliances will
satisfy virtually all requirements for indoor, wall or ceiling
mount applications.
Strobe options for wall mount models include 1575 or
Wheelock's Patented MCW multi-candela strobe with
field selectable candela settings of 15/30/75/11 0cd or
the high intensity MCWH strobe with field selectable
135/185cd. Ceiling mount models include the patented
MCC multi-candela ceiling strobe with field selectable
intensities of 15/30/75/95cd or the high intensity MCCH
strobe with field selectable 115/177cd.
All models may be synchronized using the Wheelock SM,
DSM Sync Modules or the PS-12/24-8CP and
PS-12/24-8MP Power Supplies with Wheelock's
Patented Sync Protocol. Synchronized strobes can
eliminate possible restrictions on the number of strobes
in the field of view. Wheelock's synchronized strobes
offer an easy way to comply with ADA recommendations
concerning photosensitive epilepsy as well as meeting
the requirements of NFPA 72.
Wheelock's Series RSS Strobes employ a Patented
Integral Strobe Mounting Plate that can be mounted to a
single gang, double gang, 4" square, 1 00m European
backboxes or the SHBB surface backbox. If the flush
backbox has side or top space between it and the
finished wall, the NAIP (Notification Appliance lrimplate)
may be used. It provides an additional .65" of trim for
the Appliance. An attractive cover plate is provided for
a clean, finished appearance on all models.
The Series RSSP Multi-Candela Strobe Plates are a cost
effective way to retrofit required wall strobe appliances to
bells, horns, chimes, multitones or speakers and easily
mounts to standard 4" backboxes or for surface mount
use with Wheelock's SBL2 surface backbox.
For Weatherproof Series RSS See Datatsheet S9004
Copyright 2004 Wheelock, Inc. All rights reserved.
'New Look
Series RSS
f1R
Series RSSP RSS Round
Multi-Candela Indicator
(bottom of Strobe Lens)
Features
Approvals include: UL Standard 1971, New York City
(MEA), California State Fire Marshal (CSFM). Factory
Mutual (FM), and Chicago (BFP) See approvals by
model in Specifications and Ordering Information
ADA/N FPNUFC/ANSI compliant. Meets OSHA 29
Part 1910.165
Wall mount Multi-Candela models are available
with Field Selectable Candela Settings of 15/30!
751110cd or 135/185cd. Single Candela models
are available in 1575cd
Ceiling mount Multi-Candela models are
available with field selectable candela settings of
15130175/95cd or 115/177cd. (Round or Square)
Strobes produce 1 flash per second over the
regulated voltage range
12 and 24 VDC models with wide UL "Regulated
Voltage" using filtered (DC) or unfiltered VRMS input
voltage
Synchronize using Wheelock's sync modules or
power supplies with built-in sync protocol
Fast installation with IN/OUT screw terminals using
#12 to #18 AWG wire
NOTE: All CAUTIONS and WARNINGS are identified by the symbolA. All warnings are printed in bold capital letters.
WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,
SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT
IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN
PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
Genera' Notes S Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second.
All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971.
Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 F to 120 F (O C
t
o
49 C) and maximum humidity of 93% (± 2%).
"Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range".
Table 1: Average RMS Current*
RSS/RSSP - Wall Mount RSS - Ceiling Mount
RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH
Models
1575cd 15cd 30cd 75cd 110Cd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd
24vdc 0.060 1 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270
UL max* 1 0.090 10.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 I 0.300 0.420 I
RSS/RSSP
24VDC
Models
12 vdc
UL max"
RSS/RSSP * RMS current ratings are per UL average RMS method. UL max Current Wall Mount rating is the maximum RMS current within the listed voltage range (16-33v
121575W for 24v units). For strobes the UL max current is usually at the minimum
listed voltage (16v for 24v units). For audibles the max current is usually at
0.152 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings,
see installation instructions.
0.255
Table 2: AudibleslSpeakers for RSSP Strobe Plate
Product Series
Multitone Appliances AMT, MT
Horns AH, NH, HS
Motor Bells MB-G6/G10
Speakers ET-1010/1080, E70, ET70
Chimes CH70
A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET (P82380) ON TH
E
S
E
PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE P
R
O
D
U
C
T
S
.
T
H
E
S
E
MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDI
N
G
:
TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES.
FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS.
ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCU
L
A
T
E
C
U
R
R
E
N
T
D
R
A
W
TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED
C
A
P
A
C
I
T
Y
O
F
T
H
E
POWER SOURCE OR FUSES.
COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW.
THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE".
INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS.
STALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES.
E STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR
TERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH.
FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER I
N
S
T
A
L
L
A
T
I
O
N
,
APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND S
E
R
I
O
U
S
INJURY OR DEATH TO YOU AND/OR OTHERS,
CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THE
S
E
P
R
O
D
U
C
T
S
,
PARTICULARLY IN RETROFIT INSTALLATIONS.
FROM
PRECEDING
APPLIANCE OR -
ACP
+ TO NEXT
PPLJeNCE
- OR ECLA
S
Wiring Diagrams
[SERIES RSS/RSSP APPLIANCE
FROM ____ TO NEXT
PRECEDING
________
APPLIANCE APPLIANCE. SYNC OR EOLR MODULE, POWER
SUPPLY OR FACP
1
SERIES RSS/RSSP APPLIANCES SYNCHRONIZED
WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT
DSM STROBE
NAC SYNC
CIRCUIT - 0 I
OUT u ——-
IN 1 ASS ASS PISS
MINuS
FACP
AUDIBLE
LTROBE
MINUS 2 I
iN2 ASS ASS ASS
CIRCUIT
RETURN
ROBE/PLATE ASSEMBLY
DIBLE & VISIBLE APPLIANCE OPERATE IN UNISON
TO NEXT
FROM
_____ _______ ______
APPLIANCE
PRECEDING ± OR EOLR
APPLIANCE, SYNC
MODULE, POWER
SUPPLY OR FACP
STROBE AUDIBLE
STROBE/PLATE ASSEMBLY
AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY
SERIES RSS/RSSP APPLIANCEYSYNCHRONIZED WITH
SM MODULE SINGLE CLASS "B" NAC CIRCUIT
Strobe - STROBE A NAC
SS C Circuit
SJEOLR
Audibjep
Audible,
SERIES RSS/RSSP APPLIANCES SYNCHRONIZED
WITH MULTIPLE DSM MODULES
DSM #1
Strobe NACCir. SC i-i + I RSSI IRSSI F
DSM #2
A
Strobe NAC Cir. .sYnc ASS ASS C DSM #3 P ____ Sync
Strobe NAC Cir.
DSM Interconnecting wiring shown. Maximum of
twenty (20)
SERIES RSS/RSSP APPLIANCES SYNCHRONIZED
WITH PS-12/24-8CP or PS-12/24-8MP
Series PS-2/24-81VIP
AS RSS
F -
EOLR
1-4
4-CLASS
A OR AS ASS
C 2-CLASS
P
AS RSS
_
Series PS-12J24-EMP ]a
PRECEDING I - i r - - - - - STROBE OR
FROM -
- + TO NEXT
STROBE. SYNC
- - 1 11 r - - - - - - EOLR MODULE. POWER
SUPPLY OR FACP I I I
0
STROBE APPLIANCE
For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For
•
wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12!24-8MP.
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and
operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance
with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed
by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA). Underwriters Laboratories
(UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county. province, district, federal and other
applicable building and flre standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and th
e
requirements of the local authority having jurisdiction (AHJ).
Architects and Enaineers Soecifications
The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL
Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet
the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range
and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of
circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and
IT
hall have the same electronic circuitry as the Wheelock Series RSS.
he Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable ettings and shall be rated per UL Standard 1971 at 15/30/75/ll0cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount.
he selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 1Listing with 75 candela on axis is required (e.g. ADA compliance).
When synchronization is required, the appliance shall be compatible with Wheelock's SM. DSM Sync Modules or Wheelocks PS-12124-8CP and PS-
12124-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the
sync module or Power Supply fails to operate. (i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall
be designed for indoor surface of flush mounting.
The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang,
4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided.
An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw
heads visible when the installation is completed.
The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the
Wheelock SBL2 backbox for surface mounting.
All notification appliances shall be backward compatible.
NOTE: Due to continuous development of our products. specifications and offerings are subject to change without notice in accordance with Wheetocti. Inc. standard terms and conditions.
Specifications and Ordering Information
M d 0 e Order
Code
Wall
Mount
Ceiling
Mount
Non-
Sync
I I Strobe
Candela
24
VDC
12
VDC
Color
RED
Color
WHITE M --- oun ing ptions
Square
or
Round
-
Agency Approvals
UL ____F
CS
FM MEA __ - FM - BFP
RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,EF,G.H,J,N,O.R,X Square X X X X X
RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D.E,F.G.H,J,N,O.R,X Square X X X X X
RSS-241575W-FR 7471 X - X 15 (75 on Axis) X - X - B,D.E,F.G.H,J,N,O.R,X Square X X X X X
SS-241575W-FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F.G,H,J,N,O,R,X Square X X X X
-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D.E,F.G.H,J,N,O.R,X Square X X X X X
RSS-121575W-FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X
RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X *
RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,OR,X Square X X X X *
RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G.H,J,N,O.R,X Round X X X X
RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X *
RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D.E,F.G.H,J,N.O.R,X Round X X X X
RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O.R,X Square X X X X *
RSSWP2475WFR** 9013 X - X 180@ 77*F X X X - B,D,E,F,G,H,J,N,O,R.X Square X X X X *
RSSWP2475WFW** 3034 X - X 180@ 77-F X X - X B.DE.F,G,H,J,N,O,R.X Square X X X X *
RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,EZ Square X X X X X
RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D.E,Z Square X X X X X
RSSP-241575W-FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X
RSSP-24MCWH-FR 9482 X X 135/185 X X B.D,E.F,G,H,J,N,OR,X Square X x X IEIJ All models sync with Wheelock SM, DSM or PS- 12/24-8CP or PS- 1 2/24-8MP. *PENDING # Models are available in either Red or White. Call Customer Service for Order Code & Delivery.
**For Weatherproof Series RSS Strobe specifications see data sheet S9004.
***Refer to data sheet S7000 for mounting options.
WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
3 YEAR WARRANTY
Made in USA NATIONAL SALES OFFICE I
1-800-631-2148
I Canada 800 397-5777 if, I WPEAW W", E-mail: Info(wheelockinc.com I
http://www.wheelockinc.com I
WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880•FAX: 732-222-2588 S041003106
buted By:
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM
USTNG SERVICE O LISTING No. 7125-0785:141 Page 1 of 1
CATEGORY: Fire Alarm Devices for the Hearing Impaired
LISTEE: Wheelock Inc. 273 Branchport Ave. Long Branch NJ 07740
Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607
DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows:
RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 24100 24100 24100 24100 24110 24110
1215 1215
121575 121575
Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP-
24MCC, *RSS..24MCWH *RSS..24MCWHR *Rssp..24McwH *RSS..24MCCH *Rss..
24MCCHR, and *RSSP..24MCCH Model numbers may be followed by any two
alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations.
RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110110cd (Wall)
RSS-24MCW, RSSP-24MCW--Selectable 15cd, 30cd, 75cd or 1 10cd
RSS-24MCC, RSS-24MCCR and RSSP-24MCC - Selectable 15cd,
30cd, 75cd and 95cd
*Rss..24McwH *RSS24MCWHR, *RSSP24MCWH
- Selectable 135cd, 185cd
*RSS..24MCCH *RSS..24MCCHR *RSSP..24MCCH
- Selectable 11 5cd, 1 77cd
Flash rate 60 flashes/minute
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction. Models with
suffix —W, wall mount only. Models with suffix —C, ceiling mount only. All models are for
indoor use only.
MARKING: Listees name, model number, electrical/candela rating, and UL label.
APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed
electrically compatible fire alarm control units. For synchronization strobes, Models SM-
12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No.
7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details.
Rev. 06-13-06
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. . Date Issued: JUNE 13,, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
-i
9ci
7 •ii -A
Description:
Wheelock Series MIZ piezoelectric Mini Horns are compact
electronic alarm appliances that are listed under UL Standard
464 for Audible Appliances in Public Mode Fire Protection
Systems. The Series MIZ-24S models provide a field
selectable Continuous or Code 3 horn tone when connected
directly to a fire alarm control panel. They can also provide
a synchronized code 3 horn tone using the Wheelock SM,
DSM Sync Modules or PS-12/24-8CP and PS-12/24-8MP
Power Supplies. The series MIZ appliances are attractive,
offer high sound output along with low current draw and are
ideal for alarm signaling in individual rooms, apartments,
hotels, motels and offices. Color choices of red or off-white
will blend with any decor.
Applications:
Individual Rooms
Apartments
Hotels
Motels
Offices
Wiring Diagrams (for all models)
FROM
-
PRECEDING TO NEXT
APPLIANCE ~ APPLIANCE
OR EOLR OR FACP
SERIES MIZ-24S MINI HORN
TEMPORAL (CODE 3) OR
CONTINUOUS TONE
Features:
Approvals include: UL Standard 464, California St
Fire Marshal (CSFM), New York City (MEA), Fact
Mutual (FM), and Chicago (BFP)
Field selectable settings for Temporal (Code 3) or
Continuous Horn
Synchronized code 3 horn when used with
Wheelock's Sync Module
Designed to meet or exceed NFPNANSI standarc
Convenient mounting to any standard single-gang
box
Beauty plugs to cover mounting screws
No additional trimplate required for flush mounting
Fast installation with In/Out screw terminals using
#12to#18AWG
High sound output with low current draw
Available in red or off-white color
Specifications and Ordering Information
Order Mounting Agency Approvals Model Description Code Options**.UL MEA CSFM FM BFP
MIZ-24S-R 8485 124 Volt, Red B X X X X *
MIZ-24S-W 8484 24 Volt White B X X X X *
*PENDING . **Refer to Data Sheet S7000 for Mounting Options.
General Notes:
Mini Horn models are Listed for indoor use with a temperature range of 32° F to 1200 F (00 C to 49° C) and maximum humidity of 93% RH ±2%.
Rated Input voltage (either filtered DC or unfiltered full-wave-rectified FWR): 16-33 VDC (for 24 VDC MIZ-24S
models)
Copyright 2003 Wheelock Inc. All rights reserved.
Architects and Enaineers Soecifications
The notification appliance shall be a Wheelock MIZ-24S audible appliance or approved equal. The Notification Appliance
shall be electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support coded
systems operation. The anechoic sound pressure measurement on Temporal (Code 3) setting shall be 87 dBA minimum
at 24VDC. The anechoic sound pressure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC.
Operating voltages shalt be 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall
have provision for standard reverse polarity type supervision and IN/OUT wiring using terminals that accept #12 to 918
AWG wiring. The appliances shall be mounted indoors and mount on standard single-gang electrical backboxes requiring
no additional trimolates or adaoters.
Table 1: UL Listed Models and Ranges I
Reverberant dBA Anechoic dBA
Regulated: Average PerUL464@l0ft @lOft
RMS ________________... Mounting Model UL Current* Continuous ! Code 3 Continuous Code 3 Options Voltage (AMPS) dBA dBA dBA dBA
24 VDC 0.025j 832 '78.8 87.9 87.9 B MIZ-24S UL max* 0.026 85.8 81.3 90.6 89.7 B
* RMS current ratings are per UL average RM
method. UL max current rating is the maximun
RMS current within the listed voltage range (16-33
for 24v units). For strobes the UL max current i
usually at the minimum listed voltage (16v for 24
units). For audibles the max current is usually a
the maximum listed voltage (33v for 24v units). Foi
unfiltered FWR ratings, see installation instructions.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters.
AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY
BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,
CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE
PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR
DEATH TO YOU AND/OR OTHERS.
AIWARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P84408) AND "GENERAL FORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS
IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT
INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING:
TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES.
FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE
CIRCUITS.
THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE.
FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN
IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH
COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND
INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS.
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed,
operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least
twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application,
installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with
all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC),
Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building
and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the
requirements of the local authority having jurisdiction (AHJ).
NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in
accordance with Wheelock Inc. standard terms and conditions.
WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
3 YEAR WARRANTY NATIONAL SALES OFFICE
800-631-2143
Canada 800-397-5777
E-Mail: Info@wheeIockinc.com http://www.wheelockinc.com
Distributed By:
273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588
S170007/04
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTINGNo. 7135-0785:115 Page 1 of 1
CATEGORY: Audible Devices
LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740
Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607
DESIGN: Models MIZ-1 2 and MIZ-24 series horns. Refer to listees data sheet for additional detailed
product description and operational considerations.
INSTALLATION: In accordance with Iistee's printed installation instructions, NFPA 72, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model designation, electrical rating and UL label.
APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units.
If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire
Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition,
the appliance must be used with a fire alarm control unit that can generate the temporal
pattern signal. Refer to manufacturer's Installation Manual for details.
*Rev. 06-13-2006
11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
-
1 WP
AD :1 mw
Heiping Peope Take ACtiflSM
SERIES AS
SINGLE & MULTI-CANDELA
AUDIBLE STROBE APPLIANCES
SERIES AH AUDBLES
Description
Wheelock's patented 2-wire Series AS Audible Strobe
Appliances and Series AH Audibles offer more features
with low current draw.
S
S
Strobe options for wall mount models include 1575cd or
Wheelock's patented MCW multi-candela wall strobes
with field selectable candela settings of 15130/75/11Ocd,
or the high intensity MCWH strobe with field selectable
135/185cd.
Ceiling mount models incorporate Wheelock's patented
MCC multi-candela ceiling strobe with field selectable
intensities of 1 5/30175195cd or the high intensity MCCH
strobe with field selectable 115/177cd.
The audible provides a selectable choice of either a
continuous horn or temporal pattern (Code 3) when
constant voltage from a Fire Alarm Panel (FACP) is
applied. Each tone has 3 dBA settings to choose from.
When used with the Wheelock Series SM or DSM Sync
Module or Wheelock PS-12/24-8CP and PS-1 2/24-8MP
Power Supplies with Patented Sync Protocol,
synchronization of the continuous horn tone provides the
temporal (code 3) tone (mandated by NFPA 72)
simultaneously for all audible appliances. This ensures a
distinct temporal (code 3) pattern when 2 or more audibles
are within hearing distance. If not synchronized the
temporal sound could overlap and not be distinctive. At
the same time the strobes will be synchronized. This
provides the ability to comply with ADA guidelines
concerning photosensitive epilepsy and the NFPA
standards when installing 2 or more visual appliances
within the field of view all of this plus the ability to silence
the audible is achieved by using only 2 wire.
For Weatherproof Series AS, See Datasheet S9004
Copyright 2004 Wheelock Inc. All rights reserved.
SERIES AS SERIES AH
Multi-Candela Indicator
(bottom of lens)
Features
Approvals include: UL Standard 1971, UL Standard 464
New York City (MEA), California State Fire Marshal (CSFM),
Factory Mutual (FM), and Chicago (BFP). See approvals by
model in Specifications and Ordering Information.
ADNNFP1AJUFC/ANSl Compliant
Wall mount models are available with Field Selectable
Candela Settings of 15/30/75/ ll0cd or 135/185cd
(Multi-Candela models) or 1575cd (single candela
model)
Ceiling mount models are available with field selectable
candela settings of 15/30/75/95cd or 115/1 77cd
(multi-candela ceiling models)
Selectable Continuous Horn or Temporal (Code 3).
3 Selectable dBA settings (99. 95 and 90 dBA) in both
tones
Patented 2-Wire Audible Strobe Appliance.
Patented Universal Mounting Plate
Weatherproof models are available for outdoor use
Strobes produce 1 flash per second over the regulated
voltage range
12 and 24 VDC models with wide UL "Regulated
Voltage Range" using filtered DC or unfiltered FWR input
voltage
o The strobes can be synchronized using Wheelock's sync
modules or power supplies with built in sync protocol
Fast installation with IN/OUT screw terminals using
#12 to #18 AWG wires
NOTE: All CAUTIONS and WARNINGS are identified by the symbol A . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR
APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCT1ONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER
APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
S General Notes
Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash
rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second.
All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971.
Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32' F to 120' F (0' C to 49' C) and
maximum humidity of 93% (± 2%).
Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (indoor use only).
Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F
(-35°C to 66°C) and maximum humidity of 95%.
"Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL
used the terminology "Listed Voltage Range".
Table 1: Ratings Per UL 1971
Model Input Voltage VDC Regulated Voltage
Range VDC/FWR I Strobe Candela (Cd)
AS-24McW 24 16.0-33.0 15130/75/110
AS-24MCCH 24 16.0-33.0 115/177
IAS-241575W 24 16.0-330 15 (75 on As)
t
AS-121575W 12 8.0-17.5 15 175 on Axis)
AS-24MCc 24 16.0-33.0 15/30,75/95
AS.24MCWH 24 16.0-33.0 135/185
ASWP.2475W 24 16.0-33.0 75 -31°F
Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VOC Audible
Description Volume Reverberant dBA
Per UL464@lOft.
Anechoic
dBA@loft.
High
S continuous Horn Medium
Low
91
88
83
99
95
90
High
Code 3 Horn Medium
Low
87
84
79 I
99
95
90
Table 3: Average RMS Current
Audible
24 VDC Models AH-24
Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models
AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH
1575cd 1 5c 30cd 75cd
f
110cd 135cd 185cd 15cd I 30cd 75cd 95cd 115cd 177cd
24 vdc 0.062 High(99)dBA
UL max' 0.080
0.100
0.121
0.080 0.102 0.150 0.194
0.088 . 0.1251 0.200 0.267
0.250 0.320 0.088 1 0.114 0.165 10.205
0.355 0.480 0.095 0.1381 0.221 0.285
0.2501 0.320
0.355 0.480
24 vdc 0.033 Med (95) dBA
UL max* 0.043
0.080 0.060 0.0841 0.132 0.173 0.230 0.305 0.066 10.09210.145 1 0.186 1 0.230 j 0.305
0.107 0.074 0.110 1 0.190 1 0.2531 0.340 0.465 1 0.080 0.122) 0.20110.26910.3-40: 0.465
24 vdc 0.017 1 0.072 0.052 0.076 0.121 0.158 0.220 0.295 it 0.056 0.082 1 0.132 0.173 l 0.220 i 0.295 1 Low(90)dBA
UL max I 0.021 0.100 0.068 0105 0182 0245 0335 0460 0,074 1 0113 0.198 0.263 0335 0.460
I Audible Wall Mount
12 VDC Models Audible Strobe
AH-12 AS-121575W
High (99) d8A
12 vdc 0.163 0.260
UL max* 0.192 0.320
12 vdc 0.076 1 0.195
Med(95)dBA UL max'
: 0.108 0.275
12 vdc 0.039 0.175
Low (90) dBA
UL max' 0.058 0.265
* RMS current ratings are per UL average RMS method. UL max current
rating is the maximum RMS current within the listed voltage range (16-
33v for 24v units). For strobes the UL max current is usually at the
minimum listed voltage (16v for 24v units). For audibles the max current
is usually at the maximum listed voltage (33v for 24v units). For unfiltered
FWR ratings, see installation instructions.
TO NEXT
APPLIANCE APPLIANCE OR EOLR OR FACP
PRECEDING
SM
AINACI
Strob STROBE 0-
Circud
EOL.R
Audible Audible
NAC
Circuit
FROM
SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM
MODULES
DSM #1
S
A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P8
4
0
2
4
)
S
E
R
I
E
S
AS SINGLE CANDELA, (P83519)SeiesAH, (P83641) Series AH-WP AND 'GENERAL INFORMATION" SHEET (P82380) ON THESE PRODU
C
T
S
.
T
H
E
S
E
DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS.
T
H
E
S
E
M
A
T
E
R
I
A
L
S
CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, IN
C
L
U
D
I
N
G
:
TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES.
FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS.
ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCUL
A
T
E
C
U
R
R
E
N
T
DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEE
D
T
H
E
R
A
T
E
D
CAPACITY OF THE POWER SOURCE OR FUSES.
COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW.
THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE".
INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS.
INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES.
THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON
A
N
D
O
F
F
.
FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INST
A
L
L
A
T
I
O
N
,
APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAM
A
G
E
A
N
D
SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATI
O
N
O
F
T
H
E
S
E
PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS.
Wiring Diagrams
SERIES AS APPLIANCES NON-SYNCHRONIZED SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE
SINGLE CLASS "B" NAC CIRCUIT WITH ALJDIBLESILENCE FEATURE
SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE
CL.ASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE
S ØSVNC øsThc -
+ OUT
a
MINUS
* AUDIBLE
SIISI&Bi. Rc,rrp 3 - AUDIBLE
OUT2
14NUS2
SIGNAU CIRCUIT RETUR,ul
APPLIANCE APPLIANCE
DSM Interconnecting wiring shown. Maximum of
twenty (20)
SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP
and PS-12/24-8MP
ouTpuTs EOLR
F 1.4
- 4-CLASS
A 13
C
OR AS RSS 2.CLASS
P
AS ASS
Senes PS-I2J24.BCP
orP5.1V24.BMP
II For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. F
o
r
w
i
r
i
n
g
information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP.
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, install
e
d
,
o
p
e
r
a
t
e
d
,
m
a
i
n
t
a
i
n
e
d
and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often
a
n
d
i
n
accordance with local, state and federal codes, regulations and laws. Specification, application, installation. operation, maintenance and
t
e
s
t
i
n
g
must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association
(
N
F
P
A
)
.
Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), l
o
c
a
l
,
s
t
a
t
e
,
c
o
u
n
t
y
,
province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not l
i
m
i
t
e
d
t
o
,
a
l
l
appendices and amendments and the requirements of the local authority having jurisdiction (AHJ).
S
S
Architects and Enairieers SDecifications
The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or
approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor
Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet
the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit
wiring by a Fire Alarm Control Panel (FACP).
The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a
choice of continuous or temporal (Code 3) audible outputs.
The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and
shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where
Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL
Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The
selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela
UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance).
When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's
PS-12/24-8CP or PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shalt not drift out of
synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed),
the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be
silenced while maintaining strobe activation when used with Wheelock synchronization.
The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow
mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If
required, an NATP (Notification Appliance Trimplate) shall be provided.
All notification appliances shall be backward compatible.
Specifications and Ordering Information
Model Order
Code Strobe Candela NonSync
Sync w/SM OSM
PS.12124.8CP or
PS.121244MP
24
VDC
12
VOC
Wall
Mount
Ceilin g
. Mount Mounting Options
Agency Approvals
UL' MEA. CSFM' FM 812P
AS24MCWFR 9024 15/30175010 X X X X ABDEFHJ'JORX x x x x x
AS-24MCW-FW
As24TcwHFR
9025
3468
15/30/75/110
135/185
X
X
X
1<
X
X
. X
X
- A.B.D,E,FGHJ.N,O,R.X
ABOEFI1JNORX
X
x
x
x
x
x
x
x
x
AS24MCWI-IFW 3469 135/185 x x X X ABDEFHJNORX x x x x *
AS-241575W-FR 7405 15(75OnAxis) X X X X
-
. A,SO.E.FH,J,N.O.R.X X X X X X
AS-121575w-FR 7410 15 (75 onA)s) x X X X A,S.D.E,F,H,J.N.O,R.X x x x x x
AS 24MCC FR 3161 15/30/75/95 X X X X A SO E FG,H J N OR X X x x x *
AS 24MCC FW 3162 15/30175/95 X X X X A 80 E FGJ-t J N OR X X X X X
As24MccHFw 3467 115/177 X X X X ABDEFG/-IJNORX X X X X
ASWP 2475W FR 9012 75 @ -31-F X X X X I (see Data Sheet S9004) X X X X X
AH-24-R
AH-24-VV
AHI2R
AH12W
-
7892
7893
7891
7894
. x
X
X
X
x
X
X
X
X
X
.
X
X
x
X
X
X
x
X
X
X
A,S.O,E.F,Gj-l.J.N.O.R,X
ABDEFGHJNORX
ABDEFGHJ'IORX
ASDEFGlJ'40RX
X
X
X
x:
X
X
X
X
X
X
xxx
X
X
X
X
X
AH24WPR 7416 X X X X X K X )( X x
AHI2WPR 7415 X X X X X 1< X X X x
*PENDING
Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery.
**For Weatherproof Series AS/AH specifications see data sheet S9004.
***Refer to Data Sheet S7000 for Mounting Options.
NOTE:, Due to continuous development of our products, specifications and offerings are subject to change without
notice in accordance with Wheelock Inc. standard terms and conditions.
WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
NATIONAL SALES OFFICE
1-800-631-2148
Canada 800 397-5777
E-mail: Info@wheelockinc.com
http://www.wheelockinc.com
3 YEAR WARRANTY
Made in USA Distributed By:
WHEELOCK, INC. - 273 BRANCHPORT AVE LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588
S810001/05
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
O USTNG SERVCE
LISTING No. 7125-0785:131 Page 1 of 2
CATEGORY: Fire Alarm Devices for the Hearing-Impaired
LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740
Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607
DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for
the hearing impaired followed by any three alpha/numeric characters indicating lens
orientation, lettering and color.
Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W
audible/strobes for the hearing impaired followed by any three alpha/numeric characters
indicating lens orientation, lettering and color. These units with suffix -W are for wall mount
only.
Models AS-2415C, -2430C, -2475C and -2410CC audible/strobes for the hearing impaired
followed by two alpha/numeric characters indicating lens lettering, orientation and color. These
units are intended for ceiling mount only.
Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or
numeric character indicating product color.
S Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric
character indicating lettering and product color.
Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling
for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use
when mounted to Model WPBB back box.
Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed
by two alpha/numeric characters indicating lens lettering and product color. Units with
suffix C are for ceiling mount only. Units with suffix W are for wall mount only.
Refer to the listee's data sheet for detailed product description and operational considerations.
RATING: Electrical: 8-17.5/16-33 VDCNFR
Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:1 l0cd
MCW: Selectable 15cd, 30cd, 75cd, llOcd
MCC: Selectable 15cd, 30cd, 75cd, 95cd
MCWH: Selectable 135cd, 185cd
MCCH: Selectable 11 5cd, 1 77cd
INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and
in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS-
24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with
suffix -C are for ceiling mount only.
S
Rev. 06-13-06
Listing No. 7125-0785:131
Page 2 of 2
S MARKING: Listee's name, model number, electrical/candela rating, and UL label.
APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used
in conjunction with separately listed electrically compatible fire alarm control units. For indoor use
only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor.
For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-
12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's
Installation Instruction Manual for details.
These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition.
NOTE: Models ASWP-2475W, AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for
the hearing impaired applications.
*Rev. 06-13-06
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
, . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007
O Authorized By: DIANE K A REND, Senior Deputy
Program Manager
Ceiling Mount
SERIES
-
RSSWP
SERIES
RSSWP
Mounted to
WPSBB-R
SERIES
ASWP
Mounted to
WPBB.R
Th WflOC 7.
09
He1101 ng Peoe Take ActonsM
Whe&ocs Weatherproof Strobe, Audible Strobe, Audible SERIES RSSWP, ASWP, AHWP, MTWP
Horn and Multitone Strobe appliances have an extended and MT-12/24 temperature range of -31F to 150'F (-35'C to 66C) that WEATHERPROOF STROBE will
and ceiling
virtually all outdoor, severe environment wall
WEATHERPROOF AUDIBLE STROBE
UL Standard 1638 Listed and rated for 180 candela on AND WEATHERPROOF AUDIBLES axis @ 77°F (25'C) and 75 candela at -31°F (35°C) with
low current draw.
Wall Mount
The Wheelock Weatherproof Appliances are designed for
maximum performance, reliability, and cost effectiveness SERIES while meeting or exceeding the latest requirements of NFPA MTWP 72 (National Fire Alarm Code), UL Standard 1638 (Standard Mounted to for Visual Signaling Appliances), and UL Standard 464 IOB-R (Standard for Audible Signaling Appliances).
Series RSSWP Strobes, Series ASWP Audible Strobes and
Series AHWP Audibles may be synchronized when used in
conjunction with the Wheelock SM and DSM Sync Modules
or the PS-12/24-8CP and PS-12/24-8MP Power Supplies
with Patented Sync Protocol. The Series MTWP is a true
4-wire appliance. The strobe portion can be synchronized
as stated above. The multitone portion cannot, but it can
be connected to a coded fire alarm system.
Weatherproof Strobe Series RSSWP
Is UL Standard 1638 approved for Indoor/Outdoor use.
The appliances use a Xenon flashtube with solid state
circuitry enclosed in a rugged Lexan® lens to provide
maximum visibility and reliability for effective visual
signaling. The Series RSSWP mounts to a Series WPSBB
Weatherproof Backbox.
Weatherproof Audible Strobe and Audible Series
ASWP and AHWP
Is UL Standard 1638 and UL Standard 464 approved for
Indoor/Outdoor use and offer a field selectable choice
of continuous horn or temporal pattern (Code 3) when
constant voltage from the Fire Alarm Control Panel (FACP)
is applied. Additionally, the audible has three (3) selectable
dBA settings of 99, 95, and 90 dBA in both tones and,
when synchronized, may be silenced while maintaining
strobe activation. The Series ASWP mounts to a WPBB
Weatherproof Backbox while the Series AH mounts to a
WBB Weatherproof Backbox.
Weatherproof Multitone Strobe and Multitone Horn
Series MTWP and MT-12124
Is UL Standard 1638 and UL Standard 464 approved for
Indoor/Outdoor use and offers a field selectable choice
of 8 nationally and internationally recognized alerting
signals. Additionally, the audible has 2 installer selectable
sound output levels: Standard and high covering a range
(depending on selected signal) of 76-94 dBA reverberant.
The Series MTWP is a true 4 wire appliance. The Strobe
•
portion can be synchronized or non-synchronized. The
multitone (audible) portion cannot be synchronized, but it
can be connected to a coded fire alarm system. The Series
MTWP and the MT-12/24 mount to a series JOB Backbox.
Copyright 20C4 Wheelock Inc. All rights reser..ed.
SERIES AHWP
Mounted to
WBB-R ;0,
(Series MTWP Ceiling
Mount not shown)
Features
Approvals include: UL Standard 1638 and 464, California
State Fire Marshal (CSFM) and New York City (MEA),
Factory Mutual (FM) and Chicago (BFP) See approvals by
model in Table 8
Designed to meet or exceed NFPA,/UFC/ANSI 117.1/ OSHA
Part 29, 1910.165, and ADA requirements
UL Standard 1638 and UL Standard 464 listed with extended
temperature range of -31° to 150°F (-35°C to 66°C)
24 VDC with new UL "Regulated" Voltage Range: of 16-33 VDC
using filtered DC or unfiltered FWR voltage Note: The Series
MT-12/24 voltage range is 10.5- 15.6 VDC (for 12V) and 20-31
VDC (for 24V)
Sync/Non-Sync in each product. Note: The audible portion of
the Series MTWP and MT-12/24 is non sync only
Synchronize with Series SM, DSM Sync Modules or PS-12/24-8CP
and PS-12/24-8MP Power Supplies with
built-in patented sync protocol
Selectable dBA settings
Selectable alert signals
IN and OUT wiring termination that accepts two 12-18 AWG wires
at each terminal
Inputs are polarized for compatibility with industry standard reverse
polarity supervision
I Q. i; ..MU I IVNQ drIU VVIAMNINk.7Z3 are iaentinea by the symbol Aj All WARNINGS are printed in bold capital letters.
àWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,
SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS, OR WARNINGS COULD
RESULT IN IMPROPER APPLICATION, INSTALLATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
General Notes:
S Wheelock UL Standard 1638 Strobes are designed to produce 3062 flashes per minute over the Regulated Voltage Range. If used in an indoor application, UL Standard 1638 strobes must be operated at a minimum of 20 VDC to meet the NFPA-72 flash rate of 1 t 2 flashes per second and
ADA Guideline flash rate of 1 to 3 flashes per second.
Wheelock Weatherproof Appliances are designed to operate over an extended temperature range of -31F to 1507 (-35C to 66'C) and at
candela ratings represent minimum effective strobe intensity based on UL Standard 1638. Maximum humidity of 93% RH ±2%.
"Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range".
àWARNlNG: CONTACT WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS' AND GENERAL INFORMATION" SHEET (P82380) ON
THESE PRODUCTS. THE INSTALLATION INSTRUCTIONS ARE AS FOLLOWS: P84135 FOR SERIES RSSWP, P83957 FOR SERIES ASWP, P83641
FOR SERIES AH-WP. P84150 FOR SERIES MTWP AND P824671 FOR SERIES MT-12124-R. THESE DOCUMENTS UNDERGO PERIODIC CHANGES.
IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS, THESE MATERIALS CONTAIN IMPORTANT INFORMATION
THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS. INCLUDING:
Total current required by all appliances connected to system secondary power sources.
Fuse ratings on notification appliance circuits to handle peak currents from all appliances on those circuits.
Adding, replacing or changing appliances will effect current draw. Recalculate current draw to insure that the total average current and total peak
required by all appliances does not exceed the rated capacity of the power source or fuses.
Composite flash rate from multiple strobes within a persons field of view.
The voltage applied to these products must be within their REGULATED VOLTAGE RANGE".
Use strobe only on circuits with continuously applied operating voltage. Do not use strobes on coded or interrupted circuits in which the applied
voltage is cycled on and off as the strobe may not flash.
Conductor size (AWG), length and ampacity should be taken into consideration prior to design and installation of these products, particularly in
retrofit installations.
Table 1: Average Current* for Series RSSWP and
Strobe in MTWP
Strobe 75 cd @
-31°F (-35°C)
Regulated
Voltage Range
Avg. Current *
24.0
VDC
UL
Max*
,mLRSSWP 16.0-33.OVDC 0.094 0.138
able 2: Average Current* (AMPS) For Series ASWP#
High dBA Medium dBA Low dBA
Voltage Setting Setting Setting
(99) dBA (95) dBA (90) dBA
24.0 VDC 0.128 0.105 0.098
UL Max* 0.168 0.155 0.150
"Audible and Visual combined.
Table 3: Average Current* (AMPS) for Series AHWP
Voltage AH-24WP Voltage AH-12WP
AH-24WP Hi/Med/Low AH-12WP Hi/Med/Low
24.0 VDC 0.062/0.033/0.017 12.0 VDC 0.163/0.076/0.039
UL Max* 0.080/0.043/0.021 . UL Max* 0.192/0.108/0.058
Table 4: dBA Ratings for Series ASWP & AHWP
Reverberant dBA Anechoic dBA Per UL 464
@ 10 ft. Description Volume 10 ft
24 VDC 24 VDC
High 91 99 Continuous Med 88 ' 95 Horn
Low 82 90
High 85 :99
de 3 Med 82 rn 95
Low 75 90
RMS current ratings are per UL average RMS method. UL max current
rating is the maximum RMS current within the listed voltage range (16-33v
for 24v units). For strobes the UL max current is usually at the minimum
listed voltage (16v for 24v units). For audibles the max current is usually
at the maximum listed voltage (33v for 24v units). For unfiltered FWR
ratings, see installation instructions.
Table 5: Average Current* (AMPS) for 24 V Series MTWP
Audible Strobe
Tone
24.0 VDC UL Max* 24.0
VDC
UL
Max
Standard I High Standard I High
0.094 0.138
Horn 0.033 0.074 0.044 0.108
Bell 0.018 0.040 0.024 0.053
March Time 0.033 0.067 0.038 0.104
Code 3 Horn 0.026 0.069 0.035 0.091
Code 3 Tone 0.026 0.061 0.035 0.075
Slow Whoop 0.028 0.069 0.037 0.098
Siren 0.027 0.080 0.036 0.104
Hi/Lo 0.020 0.044 0.026 0.057
Table 6: dBA Ratings for Series MTWP and MT.12/24
Tone Standard i MTWP i MT-12/24
116.0124 0 33.0 120.0I
High Setting IVDC I VDC VDC IVDC
24.0
VDC
10.5 12.0
VDC VDC
Horn
Standard
High Setting ,89 i 92
84l879082
94 88
8582 85,
91 88 91.
Bell -
Standard
High Setting
76
83
80
________
86
83
88
75
82
79 75 79
______________
85 82 85
March Time Standard
High Setting
80
86
84
89
87
91 '
79
85
82 79 82
88 : 85 88
Code 3 Horn' Standard ; -ighSetttng85j8890
79183186
11
75 79:75179
858585185
Code 3 Tone;
HlghSetting
Standard (76180182
81 85 86 79 1
75175
82
75
79 1
75
82
standard 181858718282 82182 Slow Whoop;
;High Setting 87;9092188188:88;88
I
Siren Standard i 81 84 87 82 82 82 82
:High Setting 86 89 92 85! 88 85 88
77 181 84 79 79 79 79 Hi/Lo ,'High Settingj 83 86; 89 : 82 1 85 82 85
Wiring Diagrams
SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE
IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED.
FROM
+ + TO NEXT PRECEDING APPLIANCE RED 1bkPPLIANCE OR EOLR IO RFACP HI BLACK
STROBE AUDIBLE
SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24
APPLIANCES
FROM + TO NEXT
PRECEDING APPLIANCE I APPLIANCE OR
I OR EOLR FACP
SERIES MTWP APPLIANCES SYNCHRONIZED STROBE
OPERATION WITH CODED FACP
MT'VP
Sync Circuit I
Module NACel
—o Audible S-la'2•a
Power
FACP Supply
NAC ;2!
I Note: Strobe circuit requires constant volt
SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED V
DSM MODULE SINGLE CLASS "A" NAC CIRCUIT
DSM STROBE
NAC SYNC 0 CIRCUIT
OUT OUT1
ii
0 Ni
0M1NUS1
___
0
L
FACP
0
MINUS 2
0 + IN 2
:__E1',RSS TROBE ______ _____
NAC ________
CIRCUIT
RETURN
Model Number Order
Code
Strobe cd
@77°F
Strobe cd
@-31°F dBA Input
Voltage
Outdoor
MountingOrder
Back B
Code
-
Agency Approvals
Strobe UL MEA CSFM !FM BF
RSSWP-2475W-FR 9013 180cd 75cd - 24 VDC T WPSBB-R (9751) X X X X *
RSSWP-2475W-FW 3034 180cd 75cd - 24 VDC I WPSBB-W (3033) X I X I X I X
RSSWP-2475C-FR 4338 180cd 75cd - 24 VDC I WPSBB-R (9751)1 X I X I X X
RSSWP-2475C-FW 4446 180cd 75cd - 24 VDC T WPSBB-W (3033) X I X I X X I *
Audible Strobe
ASWP-2475W-FR 9012 180cd 75cd 90/95/99 24 VDC I WPBB-R (9014) X X I X X X
ASWP-2475C-FR 4251 180cd 75cd 90/95/99 24 VDC I WPBB-R (9014) X X X X X
Multitone Strobe
MTWP-2475W-FR 8420 180cd 75cd 76-94 24 VDC M 10B-R (5046) X X X X *
MTWP-2475C-FR 4457 180cd 75cd 76-94 24 VDC M lOB-R (5046) X X X X
MTWP-2475C-FW 4458 180cd 75cd 76-94 24 VDC M IOB-W (5047) X X X X - HornsfAudibles
AH-24WP-R 7416 N/A I N/A 90/95/99 24 VDC K WBB-R (2959) X X X - X
AH-12WP-R 7415 N/A I N/A 90/95/99 12 VDC K WBB-R (2959) X X X - X
MT-12/24-R 5023 N/A N/A 76-94 12/24 VDC M lOB-R (5046) X X X X X
Speaker Strobe
ET70WP-2475W-FR i9077 180cd 75cd 77-93 24 VDC M lOB-R (5046) X X X *
ET70WP-2475C-FR 4452 180cd 75cd 77-93 24 VDC M lOB-R (5046) X X X *
ET7OWP-2475C-FW 4454 180cd 75cd 77-93 24 VDC M 1013-W (5047) X I X X
Fr,r ri,nre irifrrntion nr, the ET70WP Anoliance. see Soecification Sheet S9006.
C]
ARCHITECTS AND ENGINEERS SPECIFICATIONS
The Weatherproof Strobe appliances shall be Wheelock Series RSSWP-2475 strobes or approved equals for wall and ceiling mount
applications. The Series RSSWP shall meet and be listed for UL Standard 1 638 (Standard for Visual Signaling Appliances) for Indoor!
Outdoor use. The strobe appliances shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to
33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be rated at 75cd and shall operate
over an extended temperature range of -31°F to 150°F (-35°C to 66°C). All inputs shall be polarized for compatibility with standard
reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel. When synchronization is required, the appliances shall be
compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS-i 2/24-8MP Power Supply with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, (i.e.,
contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The Series RSSWP shall be mounted only to the
WPSBB-R Backbox.
I The Weatherproof Audible Strobe and Audible appliances shall be Wheelock Series ASWP-2475 Audible Strobes for wall and ceiling
mount applicaitons and Wheelock Series AHWPAudible Horns for wall mount or approved equals. The Series ASWP and SeriesAHWP
shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use. The strobe appliances
shall produce a flash rate of 30-62 flashes per minute over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon
flashtube enclosed in a rugged Lexan® lens. The strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31°F (-35°C) and shall operate over an extended temperature range at -31°F to 150°F (-35°C to 66°C) and be listed for maximum humidity at 95% RI-i. All inputs shall
be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The Series
ASWP shall be mounted only to the WPBB-R Backbox while the Series AHWP shall only be mounted to the WBB-R Backbox.
The weatherproof audible strobe appliances shall be designed for two-wire operation and shall provide either a continuous or temporal
(Code 3) tone when constant voltage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) is applied. They
shall be designed so that the audible signal may be silenced while maintaining strobe activation. When synchronization is required, the
appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or the Wheelock PS- 12/24-8MP Power Supply
with built-in, patented sync protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync fails to
operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate.
The Weatherproof Multitone Strobe and Multitone Audible appliances shall be a Wheelock Series MTWP and MT-12/24 or equivalent.
The Series MTWP shall meet and be listed for UL Standard 1638 (Standard for Visual Signaling Appliances) for indoor/outdoor use. The
strobe portion of the appliance shall produce a flash rate of 30-62 flashes per minute over the listed voltage range of 20-31 VDC and shall
incorporate a Xenon flash tube enclosed in a rugged Lexan® lens. llhe strobe shall be rated 180cd @ 77°F (25°C) and 75cd at -31°F (-35°C) and shall operate over an extended temperature range at -31°F to 150°F (-35°C to 66°C) and be listed for maximum humidity
at 95% RH. All inputs shall be polarized for compatibility with industry standard reverse polarity of circuit wiring by a Fire Alarm Control
anel. The audible portion of the Series MTWP as well as the Series MT-12/24 shall provide eight field selectable alarm signals. The
nals shall consists of: Horn, Bell, March Time, Code 3 Horn, Code 3 Tone, Slow Whoop, Siren and Hi/Lo. Tone selection shall be by
durable dip switch assembly. Clips or Jumpers are not acceptable. The appliance shall provide two output sound levels: Standard
and High dBA. The range of dBA shall be 75 to 94 dBA. The Series MTWP shall have an operating voltage of 24 VDC (nominal) while
the Series MT-12/24 shall operate at either 12 or 24 VDC (nominal) using filtered power or unfiltered power (full wave rectified). Both
models shall have provisions for In/Outfield wiring using terminals that accept #12 to #18 AWG wiring. When synchronization is required,
the Series MTWP shall be compatible with the Series SM and DSM Sync Modules or with the Series PS-1 2/24-8MP Power Supply with
built-in, patented sync protocol. Note: The Strobe portion of the Series MTWP may be synchronized. The audible portion of the
appliance cannot. The audible portion of the appliance can be connected to a coded fire alarm system. The Series MTWP and
the Series MT-12/24 shall be mounted only to the IOB-R Backbox.
Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance
with Wheelock Inc. standard terms and conditions.
WE ENCOURAGE AND SUPPORT NICET CERTIFICATION
MADE IN THE USA
I NAALES FFIC 3 YEAR WARRANTY NATIO
800-631-2148
Canada 800-397-5777
E-Mail: lnfo@wheelockinc.com http://www.wheelockinc.com
273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 'TEL: 732-222-6880 FAX: 732-222-2588
S900402/06
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7125-0785:131 Page 1 of 2
CATEGORY: Fire Alarm Devices for the Hearing-Impaired
LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740
Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607
DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for
the hearing impaired followed by any three alpha/numeric characters indicating lens
orientation, lettering and color.
Models AS-1 215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W
audible/strobes for the hearing impaired followed by any three alpha/numeric characters
indicating lens orientation, lettering and color. These units with suffix -W are for wall mount
only.
Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired
followed by two alpha/numeric characters indicating lens lettering, orientation and color. These
units are intended for ceiling mount only.
Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or
numeric character indicating product color.
Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric
character indicating lettering and product color.
Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling
for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use
when mounted to Model WPBB back box.
Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed
by two alpha/numeric characters indicating lens lettering and product color. Units with
suffix C are for ceiling mount only. Units with suffix W are for wall mount only.
Refer to the listee's data sheet for detailed product description and operational considerations.
RATING: Electrical: 8-17.5/16-33 VDCNFR
Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd
MCW: Selectable 15cd, 30cd, 75cd, 110cd
MCC: Selectable 15cd, 30cd, 75cd, 95cd
MCWH: Selectable 135cd, 185cd
MCCH: Selectable 115cd, 177cd
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and
in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS-
24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with
suffix -C are for ceiling mount only.
*Rev. 06.13-06
Listing No. 7125-0785:131
Page 2 of 2
MARKING: Listee's name, model number, electrical/candela rating, and UL label.
APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used
in conjunction with separately listed electrically compatible fire alarm control units. For indoor use
only except Models AH-112WP and AH-24WP audible appliances are suitable for indoor/outdoor.
For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-
12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's
Installation Instruction Manual for details.
These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition.
NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for
the hearing impaired applications.
S
*Rev. 06-13-06
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
SERIES MB RSSP
REMOTE PLATE
Features
Approvals include: UL Standard 464, Factory Mutual (FM), Califorr
State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP)
Meets OSHA 29 Part 1910.165
High sound output with low current draw
Low frequency aluminum shells for better audibility through walls,
doors and other structures
6" and 10" shell sizes in 12 or 24 VDC models
Integral RFI suppression to minimize included noise on the NAC
circuit
Mounting options for surface, semi-flush, outdoor, and concealed
conduit installation
Built-in trimplate makes semi-flush mounting simpler and less
expensive
Screw terminals permit fast in-out field wiring of #12 to 18 AWG wir
Polarized for DC supervision of NAC circuits
Operates on filtered or unfiltered DC
For combined audible (bell) and visual signaling, convenient retrofi
plate assemblies are available with Multi-Candela or Single cande
strobes (Refer to Fire Alarm Products Catalog for Series RSSP Syn
Non-Sync Strobes specifications and technical information)
S
PQ NO
DA
_iTr,r-i T-.L 1
SERIES MB MOTOR BELLS 1
S
Description
Wheelock's Series MB Motor Bells provide a better
engineered motor bell for fire and life safety alarm
systems. The Wheelock Series MB Bells include higher
dBA, low current draw, built-in trimplate for semi-flush
mounting, low frequency aluminum shells, and low RFl
noise. The motor for Series MB Bells is a durable, high
torque permanent magnet motor selected for its high
performance and long life.
These DC vibrating Series MB Motor Bells are offered
in 6" and 10" shell sizes in both 12 and 24 VDC models.
Series RSSP Sync/Non-Sync retrofit plates are used in
conjunction with the Series MB Motor Bell when
combination appliances are required. The Series RSSP
retrofit plates are available with either
Multi-Candela or single candela strobes and easily
mount to a 4" square or Wheelock SBL-2 backbox. All
Series RSSP strobe appliances meet or exceed the
requirements of NFPA 72 (National Fire Alarm Code),
ANSI 117.1 (American National Standard for Accessible
and Usable Buildings and Facilities), ADA (Americans
with Disabilities Act) and UL Standard 1971 (Signaling
Devices for the Hearing Impaired).
The Series RSSP retrofit plates may be synchronized
when installed with the Wheelock Series SM, DSM, Sync
Modules or the PS-12/24-8CP or PS-12/24-8MP Power
Supply with Wheelock's patented sync protocol.
Wheelock's synchronized strobes offer an easy way to
comply with ADA requirements concerning photo-
sensitive epilepsy.
Ordering Information
C
Model
Number
Order
Code
Shell
Size
Input Voltage
(VDC)
Average RMS
Current UL Max* dBA@ 10 Ft. Mounting Options
MB-G6-12-R 3942 6" 12
12
24 I
24
12
12
24
24
______________________________________________
0.060
0.060
0.030
0.030
0.060
0.060 I
0.030
0.030 j
0.090 j
0.090
0.040
0.040 I
92 D.E,J.K.N.O.P,R,S 0.090
0.090
0.040
0.040
I MB-36-12-S 4221 6"
MB-G6-24-R 3941 6"
MB-G6-24-S 4222 6"
MB-G10-12-R • 3944 10' •
I MB-G10-12-S 4223 10"
MBG1024R 3943 10'
MB-G10-24-S 4224 10'
NOTES:
Typical dBA at 10 feet
is measured in an
anechoic chamber.
For bells all 12 VDC
models are UL rated for
9.0 to 15.6 VDC and all 2
VDC models for 18.0 to
31.0 VDC.
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v
for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually
at the maximum listed voltage (3v for 24v units). For unfiltered FWR ratings, see installation instructions.
Copyright 2005 Wheelock. Inc. All rights reserved.
Architects and Engineers Specifications
The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed
for Fire Protective Service. Shells shall be aluminum in 6' or 10' diameter. Sound output at 10 feet shall be 92 dBA. The bells shall
incorporate a permanent magnet motor and suppression circuit' to minimize RFI. They shall include a built-in trimplate for semi-
flush mounting to a standard 4' square backbox, or surface mounting to Wheelocks indoor BB backbox or outdoor WBB backbox.
For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. AU
bell models shall be polarized for line supervision and shall have screw terminals for in-out field wiring of #12 to #18 AWG wire.
Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be textured enamel.
Model Number Order
Code
Nominal Voltage
(VDC) Strobe Candela Current (AMPS)
at listed VDC UL MaMax*Average I Mounting
Options
RSSP-24MCW-FR 9402 24 15/30i75/110 .041/.063L109/.140 .060L092/.165L220 D,E.Z
RSSP-241575W-FR 7793 24 15 1,75 on-axis) .060 .090 f D.EZ
RSSP-121575W-FR 7798 12 15 (75 on-axis) f .152 .255 D.E2
* RMS current ratings are per UL average RMS method. UL max
current rating is the maximum RMS current within the listed voltage
range (16-33v for 24v units). For strobes the UL max current is
usually at the minimum listed voltage (16v for 24v units). For audibles
the max current is usually at the maximum listed voltage (33v for 24v
units). For unfiltered FWR ratings, see installation instructions.
Wiring
Fig. I Bell Models Fig. 2 Retrofit Strobe AUDIBLE STROBE Plate Models (RSSP) r - -'
1+
FROM
PRECEDING TO NEXT
FROM TO NEXT APPLIANCE OR
PACP ~ APPLIANCE + APPLIANCE OR EOLR
_____________ ___________
PRECEDING
APPLIANCE { } OR
RESISTOR
OR FACP (EOLR) FROM TO NEXT - PRECEDING STROBE OR STROBE OR + + FACP
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and
operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in
accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must
be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters'
Laboratories (UL). National Electrical Code (NEC). Occupational Safety and Health Administration (OSHA), local, state. county, province, district,
federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and
amendments and the requirements of the local authority having jurisdiction (AHJ).
AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING
SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD
RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH
COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/011 OTHERS.
NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In
accordance with Wheelock Inc. standard terms and conditions.
WE SUPPORT AND ENCOURAGE NICET CERTIFICATION
ASSEMBLED IN THE USA
7
NATIONAL SALES OFFICE 3 YEAR WARRANTY
800-631-2148
Canada 800-397-5777
E-Mail: lnfowheelockinc.com JEEMWiI.
http://www.wheelockinc.com F77" ~71111111111111
Distributed B
273 BRANCH PORT AVENUE ° LONG BRANCH, NJ 07740 ° TEL: 732-222-6880 • FAX: 732-222-2588
S1500 02105
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM
LIS"TI NG" SERVICE
LISTING No. 7135-0785:113 Page 1 of 1
CATEGORY: Audible Devices
LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740
Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607
DESIGN: Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for
outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating and UL label.
APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units.
If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire S Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition,
the appliance must be used with a fire alarm control unit that can generate the temporal
pattern signal. Refer to manufacturer's Installation Manual for details.
Rev. 06-13-2006
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
SIEMENS Fire Safety
S Intelli gent Initgo iating Devices
Manual Fire Alarm Boxes
MSl10B and MSI20B Intelligent Manual Fire Alarm Boxes
for MXL, IXL, and XL3 Control Panels
ENGI NEER AND ARCHITECT SPECIFICATIONS
Durable Design
Shock and Vibration Resistant
Pull Down Lever Remains Down Until Reset
S
Custom Microcomputer Chip Technology
a Dynamic Supervision
Polarity Insensitive with SureWireTM Technology
Reset with Allen Key
No Break Rods Necessary
Two Wire Operation
a Surface or Semiflush Installation
a DPU or FPI-32 Programs and Verifies Device's
'Address and Tests Device's Functionality
Electronic Address Programming is Easier
and More Dependable
a Single and Double Action Models Available
®, Listed, CSFM, FM and NYMEA Approved
Introduction
Siemens Building Technologies, Fire Safety Division
MSl-10B and 208 intelligent manual tire alarm boxes
provide the markets' most advanced method of
address programming and supervision, combined with
sophisticated control panel communication. Each MSI
manual fire alarm box incorporates a new custom
microcomputer chip. The microcomputer chip technol-
ogy, and its sophisticated bi-directional communication
capabilities with the control panel, achieves the state
of an "Intelligent Initiating Device."
Description
The MSI-10B and 208 are constructed of durable
molded polycarbonate material which is matte finished
in red with raised white lettering. The housing accom-
modates a "pull-down" lever which, when operated,
locks in position indicating the manual fire alarm box .has been activated. The pull down lever remains down
and locked until the manual fire alarm box is reset. The
manual fire alarm box is reset only by opening the
hinged housing cover with an allen key and then
closing and locking the cover.
Replaces Catalog No, 6162
The MSl-108 and 20B manual fire alarm boxes operate
with the MXL, lXLJlCON-1 and XL3 control panels.
The manual fire alarm box's microcomputer chip has
the capacity of storing, in memory, identification
information as well as important operating status
information.
Fire Safety's innovative technology also allows all MSI
Series Intelligent manual fire alarm boxes to be pro-
grammed by using the Model DPU or FPl-32 Program-
mer/Tester. The Programmer/Tester is a compact,
portable, menu driven accessory which makes pro-
gramming and testing a manual fire alarm box device
faster, easier and more dependable than previous
methods. The DPU or FPl-32 eliminates the need for
the device's mechanical addressing mechanisms, such
as program jumpers, dipswitches or rotary dials
because the Programmer/Tester electronically sets the
manual fire alarm box's address into its microcomputer
chip, nonvolatile memory. Vibration, corrosion and
CATALOG NUMBER 6187
S
other conditions which deteriorate mechanical address-
ing mechanisms are no longer a cause for concern.
The MSJ-108 and 20B are fitted with screw terminals
for connection to an addressable circuit. They can be
either surface or semiflush mounted.
The MSI Series manual fire alarm boxes derive their
power, communicate information and receive com-
mands over a single pair of wires.
The MS! Series is compatible on the same circuit with
all IL and (D-60 Series ionization, photoelectric or
thermal detectors, TRI Series interfaces or CZM Series
addressable conventional zone modules.
The MSI-108 and 20B intelligent manual fire alarm
boxes are Underwriters Laboratories, Inc. listed.
Mounting Data
HOUSING In.
HINGED TO
BACKPLATE
1 3A6 in wo
Ordering Information
Model Description
Shipping Wt.
Lb. Kg.
MSI-IOB Addressable Manual Fire
Alarm _Box, _Single Action
2 .90
MSI-20B Addressable Manual Fire
Alarm Box, Double Action
2.5 1.13
SB-513 Surface Mounting Box 1.5 .68
500-620490 Reset Tool Package (Contains 2 Tools) .5 .23
HOUSING
ADil \
BACKPLATE
SURFACE MOUNTING ENCLOSURE
3½ in DEEP
SWITCH BOX.
(USER SUPPLIED)
C
Siemens Building Technologies
Fire Safety
Fire Safety
8 Ferrn,00d Road
Florham Park, NJ 07932
Tel: (973) 593-2600
FAX (973) 593-6670
iVebst www.s.semenscornIfs
7'03
5 M
SFS-IG
Pnned in J,S.A.
Fire safety
2 Kenview Boulevard
Brampton, Ontario
Canada LST 5E4
Tel: (905) 799-9937
FAX: (905) 799-9853
July 2003
Sucersedes st'eer dated 4102
CAUFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM
UST I t, G SERVICE
LISTING No. 7300-0067:145 Page 1 of 1
CATEGORY: Misc. Devices/Control Unit Accessories
LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Model FP/32 field programmer/tester. Refer to listee's data sheet for additional detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name or Cerberus Pyrotronics, model number, electrical rating and UL label.
APPROVAL: Listed as an accessory device for use with Model ID60 series smoke detectors (CSFM
Listing No. 7271-0067:101, 7272-0067:121, and 7270-0067:108) and Model MSI series
boxes (CSFM Listing No. 7150-0067:036).
S
Rev. 10-26-2002
$ This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
need for cumbersome, unreliable mechanical program-
ming methods and reduces installation and service
costs by electronically programming and testing the
detector prior to installation.
The FP-11 fire detector is compatible with the MXL
family of control panels including the MXL, MXL-IQ,
and MXLV.
The FP-11 detector is Underwriters Laboratories and
Underwriters Laboratories of Canada Listed.
Description
M '01 EMENS Fire Safety
[1 FP-11 FirePrinfm Detector
Intelligent Fire Detector for MXL, MX640, and MXLV Control Panes
S
Most Sophisticated "Detector Intelligence' available today
Multi-Criteria fire detection for the price of a
photoelectric detector
FirePrintTM Technology to discriminate between deceptive
phenomena and an actual fire
Easily programmed to match specific hazard profiles from the
control panel
Pre-Alarm reporting based on fire profile selected
Remote sensitivity measurement capability
System logic activation based on any of three inputs from
detector (smoke, heat or neural network)
Field cleanable chamber with replaceable chamber
parts available
Multi-color detector status LED
Two-wire operation
Compatible with Model DPU or FPl-32 field
programmer/tester
Supports EnviroLlNK software based automatic
environmental compensation
Backward compatible with older MXL systems
(Rev. 2 and above)
Optional fully programmable relay base, audible base, and
duct housing
u UL Listed, ULC Listed, CSFM, FM, NYMEA L Approved
Introduction
The FP-ii Intelligent Fire Detector provides the life
safety industry with the most highly evolved detection
system available today. The FP-ii utilizes advanced
detection technology that allows the detector to
distinguish nonthreatening deceptive phenomena, such
as cigarette smoke, from actual fire hazards, while
optimizing detection for the area in which it is in-
stalled. No other detection system available today
offers a higher level of protection or nuisance
alarm immunity. The FP-ii uses state-of-the-art
microprocessor circuitry with error check, detector
self-diagnostics and supervision programs.
The FP-11 intelligent fire detector is compatible with .the Siemens Building Technologies, Fire Safety Divi-
sion, Model DPU or FPI-32 field programmer/tester,
which is a compact, portable, menu-driven accessory
for electronically programming and testing detectors,
easily and reliably. The DPU or FPl-32 eliminates the
CATALOG NUMBER 6175
The FP-11 is a plug-in, two-wire, multi-sensor detector
with both photoelectric and thermal inputs and is
compatible with the MXL family of control panel
systems. Each detector consists of a dust resistant,
field cleanable photo chamber, a solid state
S
non-mechanical thermal sensor, microprocessor based
electronics with a low-profile plastic cover and base.
The FP-11 utilizes state-of-the-art ASIC and surface
mount technology for maximum reliability. Every FP-11
fire detector is shipped with a protective dust cover
The FP-11 fire detector utilizes an infrared light
emitting diode (IRLED), and light sensing photodiode.
Under normal conditions, light transmitted by the LED
is directed away from the photodiode and scattered
through the smoke chamber in a controlled pattern.
The smoke chamber is designed to manage light
dissipation and extraneous reflections from dust
particles or other non-smoke airborne contaminants in
such a way as to maintain stable, consistent detector
operation. When smoke enters the detector chamber,
light emitted from the IRLED is scattered by the
smoke particles and is received by the photodiode.
The FP-11 also utilizes a modern, accurate, shock-
resistant thermistor to sense temperature changes.
The "on-board" FirePrint technology allows the
detector to gather smoke and thermal data, and to
analyze this information in the detector's "neural
network' By comparing data received with the
common characteristics of fires, or fire fingerprints,
the FP-11 can compare these "Fire Prints" to those of
deceptive phenomena that cause other detectors to
alarm. The advanced FirePrint technology allows the
FP-11 to accurately determine a true fire hazard from
a nonthreatening deceptive phenomena WITHOUT
needing to use alarm delaying verification and confir-
mation techniques, which can increase the probability
of losses due to fire.
The FP-11 provides the highest level of detector
intelligence available today with a detector/control
panel link that allows the user to program the detector
for the specific hazard profile Detectors are optimized
by selecting one of the following applications:
Office/Retail
Lobby
Computer Room
Dormitory
Healthcare
Parking Garage
Utility/Transformer Room
Hostile Environment
Precious Storage
Air Duct
Warehouse/Light Manufacturing
The software does the rest; no guessing on detector
sensitivities or alarm verification; the control panel
programs the FP-11 detector for the protected area
without hassle and without confirmation delays.
Once optimized for the hazards in the protected area,
the FP-11 provides the best detection you can buy.
evaluating this information with sophisticated
mathematical formulas, or algorithms, comparing this
input to characteristics of both threatening fires and
deceptive phenomena that would "fool" any ordinary
detector. This technology was developed over years of
research and reviewing the results of over 20 years of
fire test data in one of the worlds most advanced fire
research centers. The results of this research are the
mathematical models that form the algorithms used in
FirePrint. No other fire detector has this level of
intelligence or this amount of research and develop-
ment supporting it's design.
The microprocessor's software can identify and
disregard false input caused by radio frequency (RFI)
and electromagnetic (EMI) interference, and validates
all trouble conditions before annunciating or reporting
to the control panel. The FP-11 detector's microproces-
sor uses an integral EEPROM to store the detector's
address and other critical operating parameters which
include the assigned program values for alarm and
trouble thresholds. Communications within the
detector itself and between the FP-11 and the control
panel, or with the FPI-32 field programmer/tester, are
supervised and safeguarded against disruption by
reliable, microprocessor based error checking routines.
Additionally, the microprocessor supervises all
EEPROM memory locations and provides a high
degree of EEPROM failure fault tolerance.
In MXL(V) applications, the FP-11 determines its
operating status to be normal, in alarm, or in trouble
depending on the difference between the alarm
threshold values stored in the detector's memory and
the detector's latest analog measurement. The
detector then communicates changes in its status to
the control panel.
In addition, the MXL(V) control panel will sample the
value of the FP-1's analog signal over a period of time
in order to determine if those values indicate exces-
sive buildup in the photo chamber; if so, the MXL(V)
will indicate that the particular detector requires
maintenance.
The FP-11 is listed as a self-testing device. The FP-11's
visible light emitting diode (LED) flashes green every
4 seconds to indicate it is communicating with the
control panel and that it has passed its internal self-
test. Should the detector sense a fault or failure within
its systems, the LED will flash amber and the detector
will transmit that information to the control panel.
A quick visual inspection is sufficient to indicate the
condition of the detector at any time. If more detailed
information is required, a printed report can be
provided from the MXL panel indicating the status
and settings assigned to each individual detector.
When the FP-11 moves to the alarm mode, it will flash
amber and transmit that information to the control
panel. When the MXL(V) confirms the detectors
condition, the panel will instruct the FP-11 to flash red
and to continue flashing until the system is reset at
the control panel. At that same time, any user defined
•
Should the operator or installer forget to program the
detector, the FP-11 will revert to a default setting that
allows it to operate as a standard photoelectric or
photothermal detector.
The FP-11's FirePrint technology monitors input from
both the photo chamber and the thermal sensor,
All FP-11 detectors are approved for operation within.
the UL specified temperature range of 32 to 100
degrees F (0 to 38 degrees C).
Application Data
Installation of the FP-ll series of fire detectors
requires a two-wire circuit of 18 AVVG (minimum)
thermoplastic fixture wire enclosed in conduit, or 18
AWG limited energy, shielded cable without conduit,
if permitted by local codes. Field wiring should
conform to local and National Electric Codes and the
control panel wiring specifications.
"T-tapping" is permitted only for Style 4 (Class B)
wiring.
FP-11 fire detectors can be applied within the maxi-
mum 30 foot center spacing (900 sq. ft. areas) as
referenced in NFPA 72. This applications guideline is
based on ideal conditions, specifically, smooth ceiling
surfaces, minimal air movement, and no physical
obstructions between potential fire sources and the
detector. Do not mount detectors in close proximity
to ventilation or heating and air conditioning outlets.
Exposed joints or beamed ceilings may also affect safe
spacing limitations for detectors. Should questions
arise regarding detector placement, observe NFPA
72 guidelines.
Good fire protection system engineering and common
sense dictate how and when fire detectors are
installed and used. Contact your local Siemens
Building Technologies, Fire Safety Division authorized
sales outlet whenever you need assistance applying
FirePrint in unusual applications. Be sure to follow
NFPA guidelines, UL/ULC approved installation
instructions, which are included with every detector,
and local codes as for all fire protection equipment.
Dimensions
system alarm functions programmed into the system
are activated. Each FP-11 detector can operate one
remote alarm indicator, one auxiliary relay, or one
audible base.
Detector sensitivity, calibration, and identification are
dynamically supervised by the control panel. Detector
sensitivity and pre-alarm levels are a function of the
application chosen at the control panel and are
controlled by the panel. If an alternate, non-FirePrint
mode is selected, then the sensitivity can be changed
from the control panel.
The DPU or FPl-32 Program/Test accessory is used to
program and verify the detector's address. The
technician selects the accessory's program mode to
enter the desired address. The DPU or FPI-32 auto-
matically sets and verifies the address and tests the
detector. It also allows the user to change the device
ID from that of an FP-11 to an older detector ID such as
an lLP-1, ILPT-1, ILP-2, ID-60P or ID-60PT to allow for
easy replacement of older detectors without the need
of reprogramming the control panel.
The FPl-32 operates on AC power or rechargeable
batteries, providing flexibility and convenience in
programming and testing equipment almost anywhere.
When in the test mode, the DPU or FPl-32 will perform
a series of diagnostic tests without altering the
address or other stored data, allowing technicians to
determine if the detector is operating properly.
S The FP-11 fire detector may be installed on the same
initiating circuit with IL or ID series detectors (Photo-
electric, thermal, or ionization), MSl series manual
stations, TRI series interfaces, ICP output control
devices, or CZM series of addressable, conventional
zone modules.
All FP-11 detectors can be cleaned in the field, when
required, by simply removing the detector cover and
unsnapping the photo chamber. There is also the
option of cleaning the interior of the detector with a
clean, soft cloth or brush, or replacing the labyrinth and
bug screen included in the detector maintenance kit,
model DMK-11.
The FP-11 uses the low profile surface mounting base,
model DB-11. This base mounts on a 4-inch octagon,
square, or a single gang electrical box. The base
utilizes screw clamp contacts for electrical connections
and self-wiping contacts for increased reliability. The
base can be used with the optional LK-1 1 detector
locking kit which contains 50 detector locks and an
installation tool, to prevent unauthorized removal of
the detector head. The DB-11 base has integral decora-
tive plugs to cover the outer mounting screw holes.
The FP-11 is electrically compatible with existing MXL
detector accessories including relays, remote lamps,
S duct housings, and audible bases. With duct housings,
a base adapter and new detector housing cover are
required (order AD-li UK upgrade kit). To use existing
D13-3S base or audible base, the FP-11 requires a DB-
ADPT base adapter.
S
S
Tech*ai Specifications
Current Requirements: Normal 750 pa Alarm 750 pa
Operating Temperature: +32°F (0°C) to 100°F (38°C)
per UL 268/268A
Humidity: 0-93% Relative Humidity
Non-Condensing
Ordering Information
Model Description
Part
Number
FP-11 Addressable FirePrint Fire Detector 500-095112
DB-li Detector Mounting Base for Series 11 500-094151
DB-I1E Detector Base (Small) 500-094151E
AD-lip Air Duct Housing for Series 11 500-095656
AD-I1XPR Air Duct Housing w/Relay for Series 11
Intelligent Detector
500-096062
ADBX-11 Audible Base 500-096181
DB-XI1RS Relay Base for Series 11 Intelligent Detectors 500-096125
RLI-1 Remote (red) alarm indicator- 4 octagon box mount 500-390573
RLI-2 Remote (red) alarm indicator- single gang box mount 500-390674
LK-11 Base Locking Kit for Series 11 detectors 500-695350
DMK-11 Series 11 Maint Kit (replacement labyrinth and bug
bug screen)
500-695338
AD-Il UK Air Duct Housing Cover/Adapter Kit 500-695967
DB-ADPT Base Adapter to 08-3S Base 500-094187
In Canada Order:
FP-17C Addressable FirePrint Fire Detector (ULC( 500-095112C
08-11C Detector Mounting Base for Series 11 (ULC) 500-095687
AD-IIPC Air Duct Housing (ULC) 500-095984
DB-XI1RSC Relay Base for Series 11 Intelligent Detectors (ULC) 500-096125C
ADBX-11C Audible Base for Series 11 Intelligent Detector (ULC) 500-096181C
Siemens Building Technologies
Fire Safety
Fire Safety
3 Fernwood Road
Fiorharn Park, NJ 07932
Tel 9731 593-2600
FAX. (973) 593-6670
Nebsite. ww'.,sbt.s;emer,scorn/fis
6/03
10M
SFS-1G
Prritd in U S A
Fire Safety
2 Kenview Boulevard
Brampton, Ontario
Canada L61 5E4
Tel: (905) 799-9937
FAX: )905) 799-9853
June 2003
Suosrsedes sheet dated 7102
S
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
USfiNG SERVICE
LISTING No. 7272-0067:203 Page 1 of 1
CATEGORY: Photoelectric Smoke Detector
LISTEE: Siemens Building Technologies Inc., Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Models FP-1 1 HFP-1 1, and *HFP0..1 I analog and FP0-1 1 photoelectric type smoke
detectors. Models FP-1, and HFP-11 also have a supplemental 1350F heat sensor. Model DGH-1 1 detector guard housing suitable for use with Models HFP-1 1, *HFp0..1 1 and FP-11 smoke detectors. Refer to listee's data sheet for additional detailed product
description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. These detectors are
intended for installation on a vertical wall surface or the ceiling. They are also acceptable
for duct application with an air velocity of 04000 ft/mm. when used with Models DB-1 1,
DB-HR or DB-X1 IRS bases.
MARKING: Listee's name, model number, and UL label.
APPROVAL: Listed as photoelectric type smoke detectors for use with listee's separately listed base Model
DB-11, 06-HR or DB-X11RS (CSFM Listing No. 7300-0067:134) and separately listed
compatible fire alarm control units. Model DGH-1 1 detector guard housing is listed for use
only with FP-1 1 and HFP-1 1. Refer to listee's Installation Instruction Manual for details.
*Rev. 09-27-2004
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
S Date Issued: JUNE 9, 2006
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
Listing Expires June 30, 2007
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
USTNG SERVICE
LISTING No. 7300-0067:134 Page 1 of 1
CATEGORY: Misc. Devices/Control Unit Accessories
USTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Models D134T, D134TS, D134F, D134TF, DB4FS, D133S, ADB3, ADBX3, DB-HR, DBX3RS,
D8-1 1, DB-X1 1 RS, AD13I60, ADB-1 1 ADBH-1 1, ADBX-1 1 and 8837 detector bases and Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3
auxiliary relays. Model DB-11 is suitable for use only with Model RR-1 1 or RR-1 1 F
auxiliary relay. Models DB-1 1 base, ADBH-1 1 audible base, and DB-HR relay base are
intended to be used with Models HFP-1 1 and HFPT-1 I Intelligent Series smoke and heat
detectors (CSFM Listing No. 7272-0067:223 and 7270-0067:224). Refer to listee's data
sheet for additional detailed product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. Model DB-1 1, ADBH-1 1
and DB-HR may be installed on the ceiling or on the wall.
MARKING: Listees name or Cerberus Pyrotronics, model number, electrical rating and UL label.
APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and
fire alarm control units.
*Rev. 10-28-2002 JEW
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ., recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
•
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
r
L
Fire Safety
IntelligentThermal Detector for MXL MXUQ and MXLV Control Pane's
ENGI NEER AND ARCHITECT SPECI FICATIONS
FPT-11
Microprocessor Based Design
Rate of Rise and Fixed Temperature
S
Innovative Technology Provides High Speed,
Fault Tolerant System/Detector Communications
Multi-Color Detector Status LED
Optional Fully Programmable Relay Base and
Audible Base
Two-Wire Operation
Backward Compatible with Older MXL Systems
(Rev 2 and Above)
Compatible with DPU or FPI-32 Field
Programmer/Tester
• @Listed, ULC Listed
CSFM, FM, NYMEA Approved
Introduction
The FPT-11 intelligent thermal detector provides an
advanced method of detection, address programming and
supervision, combined with sophisticated control panel
communication.The FF1-il detector uses a state-of-the-
art thermistor providing 135°F fixed temperature and 15°
per minute rate-of-rise alarm points. The user also has the
option of disabling the rate-of-rise feature leaving just a
fixed temperature sensor.
The FPT-1 1 intelligent thermal detector is compatible with
the DPU and FPI-32 field programmer/testers.These
testers are compact, portable, menu-driven accessories
which make programming and testing detectors faster,
easier and more reliable than other methods. They
eliminate the need for cumbersome, unreliable mechani-
cal programming methods and reduce installation and
service costs by electronically programming addresses
and functionally testing the FF1-il's performance before
the detector is installed.
The FPT-i 1 thermal detector operates with the MXL
family of control panels including MXL, MXL-10
and MXLV
The FPT-1 1 intelligent thermal detector is Underwriters
Laboratory listed and Underwriters Laboratory of
Canada listed.
Description
The FPT-11 is a plug-in, two-wire thermal detector,
compatible with the MXL family of control panels.
Each FPT-11 has microcomputer chip technology and
highly stable solid state electronic circuitry.
The FPT-11 utilizes a modern, accurate, shock-resistant
thermistor to sense temperature changes. This elec-
tronic sensing method virtually eliminates thermal lag
associated with mechanical temperature sensing
devices and provides almost instantaneous tempera-
ture information to the control panel. The FPT-11, in its
default mode, is a combination 135°F fixed tempera-
ture and 15° per minute, rate-of-rise detector. It can
be programmed from the control panel as a fixed
temperature detector without rate-of-rise, at the
users option.
CATALOG NUMBER PL
The FPT-11 detector's microprocessor uses an integral
EEPROM to store the detector's address. Communi-
cations within the detector itself and between the FPT-
11 and the control panel, or with the FPI-32 field
programmer/tester, are supervised and safeguarded
against disruption by reliable, microprocessor based
error checking routines. Additionally, the microproces-
sor supervises all EEPROM memory locations and
provides a high degree of EEPROM failure fault
tolerance.
The FF1-li is listed as a self-testing device. The FFT-ll's
visible light emitting diode (LED) flashes green every 4
seconds to indicate it is communicating with the control
panel and that it has passed its internal self-test. Should
the detector sense a fault or failure within its systems,
the LED will flash amber and the detector will transmit
that information to the control panel. A quick visual
inspection is sufficient to indicate the condition of the
detector at any time. If more detailed information is
required, a printed report can be provided from the MXL
panel indicating the status and settings assigned to each
individual detector.
When the FF1-li moves to the alarm mode, it will flash
amber and transmit that information to the control panel.
When the MXL(V) confirms the detectors condition, the
panel will instruct the FPT-i 1 to flash red and to continue
flashing until the system is reset at the control panel. At
that same time, any user defined system alarm functions
programmed into the system are activated. Each FPT-11l
detector can operate one remote alarm indicator, one
auxiliary relay, or one audible base; but only one acces-
sory per detector.
A DPU or FPl-32 programmer/tester is used to program
and verify the detector's address. The user selects the
Program Mode to enter the desired address. The pro-
grammer/tester then automatically sets and verifies the
address as well as tests the detector. The programmer/
tester has rechargeable batteries, so a detector's address
can be programmed by the user from the most conve-
nient location. The user can also separately test the
detector for functionality. When the user selects theTest
Mode, a series of tests are automatically conducted and
the user is informed whether the detector has passed
or failed.
The FPT-i 1 detector is compatible on the same MXL
initiating circuit with other IL Series, FP Series or ID-60
Series addressable ionization, photoelectric, or thermal
detectors, MSI addressable manual stations, TRl
Series addressable interfaces, or CZM Series addressable
conventional zone modules.
Each FF1-il thermal detector is capable of operating one
"X" or "I" Series remote alarm indicator or auxiliary relay
or audible base.The FF1-li detectors use a surface
mounting base, Model DB-ll, which mounts on a 4-inch .octagonal, square or single gang electrical box. Relay base
Model DB-X11 RS mounts to a 4-inch square deep
electrical box. Audible base Model ADBX-11 also mounts
to a 4-inch square deep electrical box.
The DB-i 1, and the DB-X1 1 RS and ADBX-1 1 use screw-
clamp terminals for all electrical connections and self-
wiping contacts for reliability, The bases also contain a
provision for an optional concealed locking mechanism to
prevent unauthorized removal of the detector head, Model
LK-ll.
Application Data
The MXL uses ALD loop circuits with each circuit
capable of supporting up to sixty FPT-11 intelligent
detectors.
The detector, or group of detectors, require a two-wire
circuit of minimum 18 AWG thermoplastic fixture wire
enclosed in conduit, or minimum 18 AWG limited
energy, shielded cable without conduit if permitted by
local building codes. Wiring should conform to local
and National Electrical Codes, and to the control
panel's wiring specifications. T-tapping is permitted
only for Style 4 (Class B) wiring.
Locate the FPT-11 on the ceiling, at least 4 inches from
the side walls. For an ideal, smooth ceiling condition,
place the detectors at a maximum center spacing of 50
feet (2500 square feet), 25 feet from side walls or
room partitions.
Actual job conditions and sound engineering judge-
ment must determine detector spacing. Consider
environmental factors including ambient temperature
fluctuation, and the nature of the fire hazard. Room
or area configuration and ceiling type (sloped or flat,
smooth or beamed) also dictates placement.
Should questions arise regarding detector placement,
follow the drawings provided and/or approved by
Siemens Building Technologies, Fire Safety Division
or by its authorized distributors. This is extremely impor-
tant! The detector placements shown on these drawings
were chosen after a careful evaluation of the area being
protected. Fire Safety's extensive experience in design
of the system assures the best detector placement by
following these drawings.
Technical Specifications
Current Requirements: Normal 750 pa
Alarm 750 pa
Operating Temperatures: -i-32°F (0°C) to
100° F (38°C)
Humidity: 0-93% Relative Humidity
Non-condensating
Orderfrg Informati on
Model Description I Part No
FF1-I1 Addressable Thermal Fire Detector 500-095918
OB-li Detector Mounting Base for Series 11 500-094151
OB-II E Small 4.5 inch Diameter Detector Base 500-094151 E
DB-X1iRS Relay Base for Series 11 Intelligent
Detectors
500-096125
ADBX-11 Audible Base for Series Ii Intelligent
Detector
500-096181
RU - I Remote (red) alarm indicator-octagon
box mount
500-390673
RLI-2 Remote (red) alarm indicator-single
gang box mount
500-695350
LK-11 Base Locking Kit for Series 11 1 500-695350
DB-ADPT Base Adapter to 08-3S Base 500-094187
In Canada Order:
FPT-1 1 C Addressable Thermal Fire Detector )ULC) 500-095918C
DB-11C Detector Mounting Base for Series 11)ULC) 500-095687
DB-X11RSC Relay Base for Series II Intelligent
Detectors )ULC)
500-096125C
ADBX-11C Audible Base for Series II Intelligent
Detector )ULC)
500-096181C
Dimensions
S
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM . US11NG SERVICE
LISTING No. 7270-0067:202 Page 1 of 1
CATEGORY: Heat Detector
LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Model FPT-1 1 electronic fixed temperature heat detector. Refer to listees data sheet for
additional detailed product description and operational considerations.
RATING: 1350F fixed temperature
INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name or Cerberus Pyrotronics, model number, temperature rating and UL label.
APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units.
Intended for use with listees Model DB-1 1 base (CSFM Listing No. 7300-0067:134).
Rev. 10-26-2002
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
•
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K AREND, Senior Deputy
Program Manager
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
S USTNG SERVICE
LISTING No. 7300-0067:134 Page 1 of 1
CATEGORY: Misc. Devices/Control Unit Accessories
LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Models DB4T, DB4TS, DB4F, DB4TF, DB4FS, DB3S, ADB3, ADBX3, DB-HR, DBX3RS,
DB-1 1, DB-X1 1 RS, ADBI60, ADB-1 1 ADBH-1 1, ADBX-1 1 and 8837 detector bases and
Model DB-ADPT detector/base adapter. Suitable for use with Models RR2 or RR3
auxiliary relays. Model DB-1 1 is suitable for use only with Model RR-1 1 or RR-1 1 F
auxiliary relay. Models DB-1 1 base, ADBH-1 1 audible base, and DB-HR relay base are
intended to be used with Models HFP-1 1 and HFPT-1 1 Intelligent Series smoke and heat
detectors (CSFM Listing No. 7272-0067:223 and 7270-0067:224). Refer to Iistee's data
sheet for additional detailed product description and operational considerations.
INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. Model DB-11, ADBH-1 1
and DB-HR may be installed on the ceiling or on the wall.
S MARKING: Listees name or, Cerberus Pyrotronics, model number, electrical rating and UL label.
APPROVAL: Listed as detector bases for use with separately listed compatible smoke detector heads and
fire alarm control units.
Rev. 10-28-2002 JEW
S
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
MEMENS
Fire Safet
TRI Series
Intelligent Initiating Devices interface Modules
for MXL Fire Detection Panels TR-S,TRD,TRFR
S
Interfaces and Supervises Normally Open Contacts
Integral SPDT Relay (up to 4 amps) on TRI-R Model
Dual Input on TRI-D Model
Multi-color L.E.D. indicates status (green, amber, red)
Easy front access to programming port and
wiring terminals
Mounts in 4 inch square 21/4 deep box, or double
gang box
Dynamic Supervision
Comes with 5x5 inch faceplate
Two wire operation
Model DPU or FPl-32 Programs and Verifies
Device's Address and Tests Device's functionality
Electronic Address Programming is Easy
and Dependable
0L UL Listed, ULC Listed
CFSM, FM, NYMEAA Approved
PIN
Welft—
,
module reports the contact's status to the control
panel. The TRI-S model can only monitor and report the
status of the contact, while the TRI-R incorporates an
addressable Form C relay. The TRI-R relay and contact
device input are controlled at the same address. For
the MXL system, the relay and input contact can be
controlled as a separate function. The relay is typically
used where control or shunting of external equipment
is required.
The TRI-D is a dual input module and is designed to
supervise and monitor two sets of dry contacts. This
interface module requires two address settings. The
TRI-D is ideal for monitoring a waterflow switch and its
respective valve tamper switch.
The TRI has a multi-color Light Emitting Diode that
flashes green when operating normally, amber if unit
CATALOG NUMBER 6179
Introduction
The TRI Series Intelligent interface modules are
designed to provide the means of interfacing direct
shorting devices to the MXL system's ALD loop
circuit.
The TRI Series Intelligent interface modules provide
the market's most advanced method of address
programming and supervision, combined with sophis-
ticated control panel communication. Each TRI Series
interface module incorporates a microcomputer chip.
The TRI Series microcomputer chip technology and its
sophisticated bi-directional communication capabilities
with the control panel, achieve the state of an "Intelli-
gent Device"
5 Description
The TRI Series Intelligent interface modules are avail-
able in three models. The TRI-S and TRI-A are designed
to monitor a normally open dry contact. The interface
Mounting Data
Addressable interface Model TRI-S, TRI-D, TRI-R
mounts directly into a 4 inch square 2¼ deep box
or a double gang box (user supplied). A 5 inch square
off-white faceolate is included with each TRI.
MOUNTING SLOTS
FOR 4 INCH
SVVITCHBOX
TA -51-0/-A
MODULE
JUNTING
)LES FOR
VITCHPLATE
MOUNTING SLOTS
FOR DOUBLEGANG
SWITCHBOX
Figure A
Mounting the TRI-S/-R/-D
is in trouble condition, and red to indicate a change of
state. The TRI-D flashes twice, once for each address,
the TRI-R red LED. indicates a change of state in
the relay.
The device's microcomputer chip has the capacity of
storing, in memory, identification information as 'r'eli
as important operating status information.
Siemens Building Technologies, Fire Safety Division
innovative technology allows all TRI Series intelligent
interface modules to be programmed by usiig the
model DPU or FPl-32 Programmer/Tester. The Pro-
grammer/Tester is a compact, portable, menu driven
accessory that makes programming and testing an
interface device faster, easier and more dependable
than previous methods.
The DPU or FPl-32 eliminates the need for mechanical
addressing mechanisms, such as program jumpers,
DIP switches or rotary dials, because the Programmer!
Tester electronically sets the TRI interface's address
into the interface's microcomputer chip nonvolatile
memory. Vibration, corrosion and other conditions that
deteriorate mechanical addressing mechanisms are no
longer a cause for concern.
The TRI Series is fitted with screw terminals for
connection to an addressable circuit.
The TRI Series is fully compatible on the same MXL
•
circuit with all intelligent FIR IL and ID-60 Series
detectors, MSI Series addressable manual stations
or any other addressable intelligent modules, such
as the CZM or ICR
-
All TRI Series intelligent interface modules are
UL listed.
Environmental operating conditions for all TRI Series
modules are 32°F (°C) to 120°F (49°C) with a relative
humidity of not greater than 93% non-condensating.
Ordering Information
Model Description
Shipping Wt.
Lb. Kg.
TRI-S Single Input 7 oz. 2
TRI-R Single Input w/flelay 701. 2
TRI-D Dual Input 7 oz. 2
Electrical Ratings
Current Draw (Active or Standby): 1.5mA
TRI-R Relay Ratings
Resistive: 4A, 125 VAC
4A, 30 VDC
Inductive: 3.5A, 120 VAC (0.6RF.)
3.OA, 30 VDC (0.6RE)
2.OA, 120 VAC (0.4RF)
2.OA, 120 VAC (0.35RF.)
2.OA, 30 VDC (0.35PE)
Siemens Building Technologies
Fire Safety
Fire Safety
8 Fernwood Road
Fiorharn Park, NJ 07932
Tel: 973) 593-2600
FAX. (973) 593-6670
VVabsite: www.sbt siernens.corn/fis
7/03
SM
SF S-i C-
?nnted in U S A.
Fire Safety
2 Kenvew Boulevard
Brampton, Ontaro
Canada LST 584
Tel: (905) 799.9937
SAX. (905) 799-9868
July 2003
Sucersetes she,c -,ared '.03
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM
USTNG SERVICE
LISTING No. 7300-0067:146 Page 1 of 1
CATEGORY: Misc. Devices/Control Unit Accessories
LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Models TRI-2, TRI-2D, TRI-2R, TRI-60, TRI-60D, TRI-60R, TRI-136, TRJ-136D, TRI-136R,
TRI-B6M, TRI-D, TRI-R and TRI-S addressable modules and TRI-CB supervisory module.
Refer to Iistee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name or Cerberus Pyrotronics, model number and UL label.
APPROVAL: Listed as control unit accessories for use with Model XL3 (CSFM Listing No. 7165-0067:104
and 7170-0067:151), Model MXL(CSFM Listing No. 7165-0067:144 and 7170-0067:154) or
IXL (CSFM Listing No. 7165-0067:138 and 7170-0067:153) fire alarm control units. The TRI-
CB module is designed for use with the TRI-2, TRI-21D and TRl-2R modules when interfaced
with the INX module.
Rev. 10-26-2002
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources.
is Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. AREND, Senior Deputy
Program Manager
L
S
Fire Safet
Intelligent Device Interface Module
ENGINEER AND ARCHITECT SPECIFICATIONS
Intelligent Interface Modules For
MXL and IXL Control Panels
Interfaces and Supervises Normally Open (Fire Detection)
or Normally Closed Contacts (Security Detection)
Compact Size Allows Mounting in Single Gang Box
Behind Equipment
Operates with MXL ALD Loop, MXL XLD Loop
or IXL lCon Loop
Microcomputer Chip Technology
Innovative Technology Supports Comprehensive System
and Interface Communication
Dynamic Supervision
Two Wire Operation
SensorUNK, model FPI-32 Programs and Verifies
Device's Address and Tests Device's Functionality
a
S Electronic Address Programming is Easier and
More Dependable
Listed, ULC Listed, CSFM and NYMEA Approved
Introduction
TheTRl-B6M Intelligent interface module is designed
to provide the means of interfacing direct shorting
devices to the MXL system's ALD loop circuit, MXL XLD
loop or the IXL system's ICon loop circuit.
lhelRl-B6M Intelligent interface module provides the
market's most advanced method of address program-
ming and supervision, combined with sophisticated
control panel communication. Each TRI-B6M interface
module incorporates microcomputer chip technology
and its sophisticated bi-directional communication
capabilities with the control panel.
Description
The TRl-136M is designed to monitor a normally open or
closed dry contact and reports the contact's status to
the control panel. .The device's microcomputer chip has the capacity of
storing, in memory, identification information as well
as important operating status information.
wire nuts.
Siemens Building Technologies, Fire Safety Division
innovative technology allows aIlTRI-B6M intelligent
interface modules to be programmed by using the
SensorliNK model FPl-32 Programmer/Tester. The
FPl-32 Programmer/Tester is a compact, portable, menu
driven accessory that makes programming and testing an
interface device faster, easier and more dependable than
previous methods. The FPl-32 eliminates the need for
mechanical addressing mechanisms, such as program
jumpers, DIP switches or rotary dials, because it electroni-
cally sets theTRl-86M interface's address into the
interface's microcomputer chip non-volatile memory.
Vibration, corrosion and other conditions that deteriorate
mechanical addressing mechanisms are no longer a cause
for concern. This TRl-B6M is connected to the programmer/
tester with the programming cable provided with the
tester. This cable utilizes two (2) alligator clip connec-
tors, to attach to the TRl-136M. (P/N 110-694927)
The TRI-136 Series has five leads, one for grounding,
which are wired to the system with user supplied
CATALOG NUMBER 6170
The TRI-136M is fully compatible on the same MXL
circuit with all intelligent IL and ID-60 Series detectors, is MSI Series addressable manual stations or any other
addressable intelligent modules, such as the CZM or
ICR The TRI-136M is also fully compatible on the IXL
(ICon) circuit with all intelligent IL and ID-60 detectors
and MSI manual stations.
AllTRI-B6M intelligent interface modules are UL and ULC
listed.
Environmental operating conditions for allTRl-B6M mod-
ules are 32°F (°C) to 120°F (49°C) with a relative humidity
of not greater than 93% non-condensating.
Engineer & Architect Specifications
The addressable interface module shall incorporate a
custom microprocessor based integrated circuit that
shall provide communication with its compatible
control panel.
The addressable interface module shall be a Fire Safety
TRI-136M that shall be compatible with a IXL or MXL
control panel.
The TR I-B6M intelligent interface modules shall provide
the means of interfacing direct shorting devices to the
control panel's addressable circuits. The interface
module shall report the contact's status to the control
panel.
The TRl Series devices shall be capable of and listed for
interfacing normally closed security switches to the
MXL (per UL 1076).
The addressable interface module shall be UL and ULC
listed.
The addressable interface module shall be dynamically
supervised and uniquely identifiable by the control
panel.
The addressable interface module's address shall be
programmed with the use of a portable programming
accessory. The programming accessory shall be a Fire
Safety FPl-32 Programmer/Tester. The portable program-
mer shall be menu driven. Once the desired address is
entered the programmer shall set and verify the address.
The programming accessory shall also be capable of
testing the interface's functionality. The addressable
interface module's address shall be set by electronic
means only. No mechanical means such as programming
pins, DIP switches or rotary dials shall be required.
The TRI-B6M shall be compatible on the same MXL circuit
with other intelligent IL and ID-60 Series detectors, TRl
Series addressable interfaces, MSI Series addressable
X ,
anual stations or any other MXL addressable intelligent
odule. TheTRI-86M shall be compatible on the same
L (ICon) circuit as other intelligent IL and ID-60 Series
detectors, MSI Series manual stations and IRI Series
interfaces.
Ordering information
Shipping Wt.
Model Description oz. Kg.
rRI86M Single Input 3,5
TRI-86M.0 ULC Model for Canada 3,5
Typical Wfrkig
(Refer to Figures 1, 2, 3 or 4) Refer to the appropriate
wiring diagram below and wire the addressable inter-
face module accordingly.
Note: Recommended wire size:
18 AWG minimum
14 AWG maximum
Installing A Security Point
WARNING: These circuits intended for 24 hour
S alarm monitoring only.
UL 1076 requires a TSW-1 tamper switch as well as a
TSP-40 printer. A COMMUNICATION FAILURE with a
TRI device configured for SECURITY results in a SECU-
RITY ALARM as well as a communication trouble.
When installing a TRI device in the CSG-M, be sure to
set the device usage to security. When setting the
device address using the FPl-32, select the normally
closed alarm causing input.
Connect only one switch per TRI input.
Reminder: Proper installation procedure for TRI Devices
As part of the normal installation practice each TRI
device must be functionally tested. This includes
testing the supervision through the end of the line
resistor. The following steps must be followed for each
TRI device installed:
Open the end of line resistor.
Check that the system annunciates the programmed
trouble message.
3, Return the resistor to its proper connection.
Change the state of the switch to confirm that the
systems programmed response is executed.
Return the switch to its normal state.
Mounting Diagram
NOTE: DO NOT USE
REAR CONDUIT ENTRY
- - - - - -
G L TRI-B6M
SINGLE GANG
I SWITCHPLATE (BLANK)
(USER SUPPLIED)
0
L. SINGLE GANG
SWITCHBOX
(USER SUPPLIED)
[1
S
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
US11NG SERVICE
LISTING No. 7300-0067:146 Page 1 of 1
CATEGORY: Misc. Devices/Control Unit Accessories
LISTEE: Siemens Building Technologies Inc., *Fire Safety Div., 8 Fernwood Rd, Florham Park NJ 07932
Contact: Peter Pawchak (973) 593-2662 FAX (973) 593-6652
DESIGN: Models TRI-2, TRI-2D, TRI-2R, TRI-60, TRI-600, TRI-60R, TRI-136, TRl-136D, TRI-136R,
TRI-136M, TRI-D, TRI-R and TRI-S addressable modules and TRI-CB supervisory module.
Refer to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name or Cerberus Pyrotronics, model number and UL label.
APPROVAL: Listed as control unit accessories for use with Model XI-3 (CSFM Listing No. 7165-0067:104
and 7170-0067:151), Model MXL (CSFM Listing No. 7165-0067:144 and 7170-0067:154) or
IXL (CSFM Listing No. 7165-0067:138 and 7170-0067:153) fire alarm control units. The TRI-
CB module is designed for use with the TRI-2, TRI-21D and IRI-2R modules when interfaced
with the INX module.
S
Rev. 10-26-2002
'
~1,
.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
'. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 9, 2006 Listing Expires June 30, 2007
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
Dual Voltage
(rear view shown)
VOL—AGE
Optional Features:
Double brass plating.
o Extension and misalignment rods.
Surface mount back box.
Time saving drill fixture
for mounting catch plate).
.7 11 Eectroinmetic F ire Door Holders
I
S
Description: DR series fire door holders arr
constructed of the finest materials and
workmanship available. The door holder is
made of durable die-cast metal finished in high
lustre double chrome or brass plating.
Other features include standard dual voltage ac
or dc inputs of 12& 24V,24& l20V and 24&
220V models. While reducing stocking
requirements, model 24120 draws a mere .020 ma.
@ 24VDC lowering overall job costs. (in large
installations the cost savings can be substantial).
Other features: single or double coil floor mounting, surface mounting and direct wall
mounting. No brackets are required. The DR series door holder offers a new installation
technique using a adhesive template assuring alignment without secondary adjustments.
Accessories include extension and misalignment rods (various lengths) enabling
parallelism between door and wail at distances greater than 12 inches and misalignment
over 4 inches.
Aiding in installation is the aircraft quality DR drill fixture that reduces installation time and
provides a near perfect alignment or catch-plate and armature, again —lowering overall installation costs.
Basic units offer superior holding force and low residual magnetism. Models 1224 and 24120 can operate at higher listed
voltages producing holding forces in excess of 1001bs. (45.3kg.) for special applications.
[1
HEt ONE1.3 DHEZ
Si
ONE3 DE
3.
75.2 fl'fl.. 0
Standard Features:
Very low current draw.
Dual voltage inputs.
Terminal block connections.
High holding force.
Law residual magnetism.
Double chrome plating.
Mounting hardware & instructions.
Extension Rod
Applications
MADE IN THE U.S.A.
Doer Holder Legend:
DH = Door Holder
F = Flush Mount
S = Surface Mount
G = Ground Mount
C = Chrome Plating
B = Brass Plating
1 = Single Coil
2 = Double Coil
NOTE: #2 indicates double coil ground
mount model.
PERFORMANCE DATA:
MODEL VOLTAGE j DC/MA AC/mA Terminals,,! LB. KG.
1224 12V .040 .038 C & L 1 30 13.6
24V .040 .036 C & H 30 13.6
•
-
24120 24V .020 .019 C & L 40L.18.1
120V
- / .020 C & H 35 15.81
24V .020 .019 C & L 40 18.1 24220 220V - .015 C & H I 25 11.3
NOTE: Holding forces listed in above table correspond with shaded
values, non shaded values are slightly less.
MODEL VOLTAGE AC/mA 1 Terminals J LB. KG.
1224 24V .085 .081 f . C&L 1 75 34.0
24120 120V - .100 C&L 110 49.8
HIGH HOLDING FORCE/SPECIAL APPLICATIONS:
To obtain performance values in table above apply high listed voltage to
ow voltage terminals (C & L).
NOTE: This configuration can only be applied to models 1224 & 24120.
Example: DH (24120) ()
Door holder I
Model/Voltage
1224, 24120, 24220
Mount Style
Surface, Flush, Ground
Extensions:
xtension rods
ACCESSORIES
Surface Mounting:
DM82 (back box)
Finish
Chrome, Brass
Coils
1,2
-----
0-
84 MM.
.3f4
02I4 1f2
70mm. 38mm,
0146? 01464.3
...L
__ 'I2
38. 1 50.8 mm.
31163 08646
-- .. - -..---_.-.(6---------
6.2 mn..
.,
Extension
Wrenches Z-
Installation Tools:
DHOF (drill fixture)
S
ACCESSORIES:
Extensions:
DHE1C 1 inch extension chrome.
DHE113 1 inch extension brass.
DHE10 1-1/2 inch extension chrome.
DHE1513 1-1/2 inch extension brass.
DHE2C 2 inch extension chrome.
DHE23 2 inch extension brass;
DHE3C 3 inch extension chrome.
DHE38 3 inch extension brass.
DHEJAC 4 inch adjustable extension
chrome.
DHEAB 4 inch adjustable extension
brass.
Hardware:
DHCPC Catch plate assembly chrome.
DHCPB Catch plate assembly brass.
DHDC Catch disc only chrome.
DHDB Catch disc only brass.
DHBBC Surface back box chrome.
DHBBB Surface back box brass.
DHW Extension wrenches.
DHDF Drilling fixture.
CALIFORNIA DEPARTMENT OF FORESTRY & FARE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM
USTNG SERVICE
LISTING No. 3550-1039:100 Page 1 of 1
CATEGORY: Door Closer/Holders/Releasing Devices
LISTEE: RSG, 3300 E. 59th St., Long Bea äh CA 90805
Contact: Louis Finkle *(562) 6304684 FAX (562) 529-5100
DESIGN: Models DH-12, -24, -120, -1224, -24120, and -24220 doorcloser!holders. Refer to listee's data
sheet for additional detailed product description and operational considerations.
RATING: 12V, 24V, 120V, and 220V
INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances.
The system is intended to be mounted in a horizontal position only.
MARKING: Listee's name, model number, rating and UL label.
APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm
control units.
Rev. 06-13-2003
'? This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 15, 2005 Listing Expires June 30, 2006
Authorized By: DIANE K. A REND, Senior Deputy
Program Manager
I
5128/5129 Save IIJ1
Fire Communi cator 4 9JJ
Cost-effective solution to most fire
communicator applications.
The 5128 and 5129 (5128/29) are four channel slave fire communicators
designed to monitor UL listed local fire alarm systems. The 5128/29 are a
cost-effective answer to most fire communicator applications and are
easy to install and service. Silent Knight knows digital communication.
With hundreds of thousands of our communicators worldwide, it shows.
For more information about the IntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
S
Description
The 5128/29 fire communicators
provide four fully supervised channel
inputs to monitor UL listed fire alarm
systems. The 5128 comes in a vinyl
and acrylic enclosure for mounting in
the fire alarm control panel (FACP)
cabinet, The 5128 can report AC power
trouble using a dry contact active high
voltage input. The 5129 comes in a
metal cabinet for surface mounting
near the FACP. The 5129 can monitor
AC voltage directly.
Features
UL listed as a slave fire
communicator for connection to UL
listed 24 VDC local FACPs
Four fully supervised input channels
programmable as voltage input
active high or low or as a contact
closure input
Dual phone line interface and line
fault monitors
Automatic 24 hour test
Reports in most major
communication formats
Compact size of 5128 allows
mounting in most local FACPs
Easy to install and service
Program the 5128 to report FACP AC
trouble immediately or delay
reporting from 6 to 12 hours
Set up direct FACP AC monitoring
from the FACP's main power input
with the 5129
Onboard rionsilencing audible alarm
Program remotely, view current
status, and change the 24 hour test
time with a PC running DOS and
Silent Knight 5541 software (5530
modem also required)
Electrical Specifications
Primary AC: 120 VAC, 60 Hz, 45 mA
Primary DC: 18-40 VDC
Total DC Load: 84 mA @ 24 VDC max
Standby Current with Annunciator:
143 mA@ 24 VDC max
Standby Current without Annunciator:
84 mA @ 24 VDC max
Alarm Current with Annunciator:
227 mA @ 24 VDC max
Alarm Current without Annunciator:
154 mA @ 24 VDC max
Channel Inputs: 18 - 30 VDC
Active High Current: 15 mA max
Dry Contact Current: 4.7 VDC, 6 mA max
AC Monitor Input (5129 only): AC
trouble output from FACP or 120 VAC
Watchdog Response: 50 sec. max
Mechanical Specifications
5128 Physical Description
Dimensions:
4" W x 8.75" H x 1.25" D
(10.2 W x 22.2 H x 3.2 D cm)
Weight: 2 lbs (0.907 kg)
Color: Black
5129 Physical Description
Dimensions:
10.1' W x 10.4" H x 3" D
(25.7 W x 26.4 H x 7.62 D cm)
Weight: 6 lbs (2.7 kg)
Color: Red
Telephone Requirements:
FCC Part 15 approved
Type of Jack: RJ31X (two required)
LEDs:
Green: Power
Red: Phone line trouble
Yellow: Faulted input and system
trouble
5128
5129
Reporting
Formats: 5K 3/1; Sescoa 3/1 SK 4/2;
SK FSK (4/2); Radionics BFSK,
Contact ID: & SlA.
Approvals
NFPA 71 & NFPA 72
UL 864
CSFM 7300-0559:120
MEA429-92-E Vol. Ill
, SILENT
KNIGHT
by Hcreywefl
5128129 Save Are Communicator
24 VDC Power
Normally Open
Contact Wiring T
Fire Alarm Channel 1
Circuit Ground
Fire Trouble Channel 2
Circuit Ground
Sprinkler Super. Channel 3
Circuit Ground -.
Fire Alarm Channel 4
Circuit Ground
Active High Output
IL Circuit Ground --- -
UL Listed Local FACP
Wiring the 5128129 to a UL Listed Local FACP
Ordering Information
5128 Slave Fire Communicator
4 Channel Slave Fire Communicator
For mounting inside FACP cabinet.
5129 Slave Fire Communicator
4 Channel Slave Fire Communicator in
Cabinet. For mounting near FACP. 5530 Modem
Accessories Modem for use uploading and
5230 Remote Annunciator downloading programming information
For programming, troubleshooting, and from 5128/29 and other Silent Knight
system operations. One per 5128/29. fire alarm accessories.
5541 Downloading Software
Allows for remote programming of the
5128/29. Download at no cost from the
Silent Knight Web site. 5530 modem
required.
5230 Cable
Cable for the 5230 remote annunciator
(PN 130294) used to connect to the
5128/29.
SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA
KNIGHT keep our product information up-to-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are FORM# 350780 Rev.B, 05/06
subject to change without notice. For more information, contact Silent Knight Y hcnevweU 7550 Meridian Circle Suite 100, Maple Grove. Mn 55369-4927. Copyright . 2006 Silent Knight
Phone: (800) 328-0103, Fax: (763) 493-6475.
CATEGORY: Misc. Devices/Control Unit Accessories
LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927
Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464
DESIGN: Models 5128 dialer card and 5129 digital alarm communicator transmitter. Refer to
listee's data sheet for detailed product description and operational considerations.
Additional information may be found in the UL Directory.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model designation, and UL label.
APPROVAL: Listed as fire alarm accessory devices when used in conjunction with separately listed
compatible control unit.
*Rev. 06-12-2006
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007
Authorized By.. DIANE K. A REND, Senior Deputy
Program Manager
C]