Loading...
HomeMy WebLinkAbout3247 CAMINO DE LOS COCHES; 100; AS130187; Permit10/27/2020 AS130187 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS 130187 3247 CAM INO DE LOS Job Address: Status: APPROVED COCHES Permit Type: SPRINK Applied 10/19/2013 Parcel No: 2550313100 Approved: 10/19/2013 Lot #: 0 Reference No.: Issued: 10/19/2013 PC #: Inspector: Project Title: TITLE BOXING TENANT IMPROVEMENT TO EXISTING FIRE SPRINKLER SYSTEM Applicant: ARNOLD'S FIRE SPRINKLERS 13168 MAPLEVIEW ST LAKESIDE CA 619-987-0295 Owner: LOS GOGH ES PROPERTIES L L C 101 N WESTLAKE BLVD #201 WESTLAKE VILLAGE CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 0 0 0 0 1/1 3t7 C-J As [:~)o GENERAL NOTES: TYPICAL Up! DOWN GETAiL — w000w ERSEW&V — AQAISTAaEAIPOOa PROVIDE NEW UPRIGHT SPRINKLER PROTECTION FOR TENANT IMPROVEMENT OF EXISTING SPRINKLERED BUILDING. SCOPE OF WORK: UI CC —C Ld zo z Ffl)OIl11, C-1- . - #l1. 1BA LII VICINITY MAP FP-1 HANGER DETAIL 1111111111 I. THE FIRE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA #13(2015) EDITION. IT IS THE RESPONSIBILITY OF THE BUILDING OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. THE SPRINKlER CONTRACTOR WILL PROVIDE THE OWNER WITH THE NECESSARY INSTRUCTION MANUALS FOR THE UP KEEP OF THE SYSTEM AS WELL AS A COPY OF NFPA #25 AT PROJECT CLOSE OUT IF APPUCABLE ONLY NEW SPRINKLERS SHALL BE USED IN THE INSTALLATION OF THE SPRINKlER SYSTEM. SPRINKLER PLANS SHALL BE MAINTAINED AT ALL TIMES ON THE JOBSTTE. AN APPOINTMENT SHALL BE MADE IN ADVANCE WITH THE APPROPRIATE FIRE PREVENTION OFFICE FOR ALL INSPECTIONS AND TESTS, ALL SYSTEM PIPING SHALL BE HYDROSTATIC TESTED AT 200 PSI FOR TWO HOURS. OR AT SO PSI ABOVE THE SYSTEM OPERATING PRESSURE WHICH EVER IS GREATER IFAPPUCABLE. ALL UNDERGROUND MAINS. AND LEAD-IN CONNECTIONS ARE DUSTING. ALL VALVES SHALL HAVE A PERMENATELY AFFIXED SIGN INDICATING ITS FUNCTION AND/OR AREA OF USE. A STOCK OF SPARE SPRINKLERS OF EACH STYLE, TYPE, AND TEMPERATURE RATING ALONG WITH A SPRINKLER WRENCH SHALL BE LOCATED NEXT TO THE THE MAIN BUILDING RISER. II. ANY PORTION OF THE SPRINKLER SYSTEM WHICH IS EXPOSED TOFREEZING SHALL BE ADEQUATELY PROTECTED AGAINST EXPOSURE. WHEN SERVING MORE THAN 105 SPRINKLERS AUTOMATIC SPRINKLER SYSTEM! SHALL BE SUPERVISED BY AN APPROVED CENTRAL PROPRIEIORY OR REMOTE STATION SERVICE AND/OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. ALL WALLS SHOWN ON PLANS ARE FULL HEIGHT WALLS (UNLESS NOTED OTHERWISE). TENANT IMPROVEMENT NOTES: ALL WORK AND MATERIALS ARE DESIGNED TO BE IN ACCORDANCE WITH THE NFPA 13 AND THE CARLSBAD FIRE DEPARTMENT REQUIREMENTS. FIRE SPRINKLERS ARE SPACED PER LIGHT HAZARD OCCUPANCY WITH A MAXIMUM SPACING OF 225 SQ. FT. ANY INCIDENTAL ORDINARY HAZARD OCCUPANCIES ARE SPACED AT 130 SQ. FT. ALL NEW PIPING TO BE SCHEDULE 30 BLACK STEEL PIPE WITH THREADABLE CAST OR DUCTILE IRON FiTTiNGS, SUPPLY NEW PENDANT SPRINKLERS FROM EXISTING BRANCH LINES. HANG ARMOVER PIPING TO ROOF! FLOOR STRUCTURE ABOVE WITH HANGERS AS DETAILED. B. FIELD VERIFY CEIUNG HEIGHTS AS INDICATED ON PLANS. A. GRAPHIC SCALE FIRE SPRINKLER LAYOUT PLAN