Loading...
HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; 150; AS100024; Permit10/29/2020 AS100024 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS100024 1950 CAMINO VIDA *fO Job Address: Status: ISSUED ROBLE Permit Type: SPRINK Applied 2/23/2010 Parcel No: 2120931200 Approved: 2/23/2010 Lot #: 0 Reference No.: I Issued: 2/23/2010 PC #: Inspector: Project Title: JITTERBUG Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE, CA 619-562-6247 Owner: CARLSBAD CC L P C/O MATTHEW J ROOT 10188 TELESIS CT #222 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) T Balance ($) 130 0 130 0 1/1 As toXDZ tqca /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series EC-8 - 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 It2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 inch (19,1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the eld user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-8 Extendeo Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number 1Y4232 - Pendent, 8.0K TY4232 is a redesignation for C4232. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 8.0 GPM/psi112 (115,2 LPM/barl'2) Page 1 of 6 MARCH, 2007 TFP223 Page 2 of 6 TFP223 Components: 3/4" ** ESCUTCHEON PLATE 1 - Frame NPT SEATING SURFACE 2 Button 3 - Sealing Assembly —_ _J 4 - Bulb 2 5 - Compression 2-1/8" Screw 3 (54,0 mm) * 6 - Deflector 1/2" _ * ( 12,7 mm) Temperature rating is NOMINAL 16" indicated on Deflector. MAKE-IN (36,5 mm) ** Pipe thread connections per ISO - 7/1 can be provided 6* on special request. FIGURE 1 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINISH (See Note 4) HAZARD TYPE TEMP. BULB NATURAL I CHROME WHITE LIQUID BRASS PLATED 1 POLYESTER LIGHT PENDENT 135Fi57°C Orange Refer to Table B for UL and C-UL ________________ 1,2,3,5 155°F/68°C Red REC. PENDENT 1350Fi57*C Orange Sensitivity Rating and w/ Style 30 Esc. 1, 2, 3, 5 Refer to Table C for FM 155°Fi68°C Red REC. PENDENT 135°F/57°C Orange Sensitivity Rating w/ Style 40 Esc. 1,2,5 155°F/68°C Red NOTES: Listed by Underwriters Laboratories, Inc. (UL), Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Temperature Ratings 135°F/57°C and 155°F/68°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ........Glass (3 mm dia.) Compression Screw ......... .........Bronze Deflector ............Brass t Registered trademark of DuPont Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be in- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). UL and C-UL Listing Requirements The Series EC-8 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and haz- ard group for all of the sprinklers in the design area. With respect to heat sensitivity, the Series EC-8 Sprinklers can be used with unobstructed construction con- sisting of flat, smooth ceilings (in- cluding bar joists) with a maximum pitch of one in six as defined and permitted by NFPA 13, The minimum allowable spacing be- TFP223 135°F 155°F AREA STYLE 16x16 Pendent OR OR 16 x 16 Style 30 Recessed OR OR 16 x 16 Style 40 Recessed OR OR 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR SR 18 x 18 Style 40 Recessed OR SR 20 x 20 Pendent OR SR 20 x 20 Style 30 Recessed OR SR 20 x 20 Style 40 Recessed SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 135°F 155°F AREA STYLE 16x16 Pendent OR OR 16 x 16 Style 30 Recessed OR N/A 16 x 16 Style 40 Recessed N/A N/A 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR N/A 18 x 18 Style 30 Recessed N/A N/A 20 x 20 Pendent OR OR 20 x 20 Style 30 Recessed OR N/A 20 x 20 Style 40 Recessed N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS Page 3 of 6 Installation The Series EC-8 Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment of an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads, and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten pendent sprin- klers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprinklers using only the W-Type 23 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figure 4 and 5) is to be applied to the sprinkler wrench flats (Rel. Figure 1). tween the Series EC-8 Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are lobe installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are lobe installed in accord- ance with the applicable Factory Mu- tual Loss Prevention Data Sheet. Infor- mation provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructons, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. Page 4 of 6 TFP223 DESCRIPTION AREA GPM PSI TY4232 (K8.0) PENDENT 16 x 16 26 10.6 18x18 33 17.0 20x20 40 25.0 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 2-7/8' DIA. 1/2±1/8" (73,0 mm) 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 ml FACE OF (57,2 mm) SPRINKLER FITTING (3,2 mm) 1/8 __ II MOUNTING MOUNTING SURFACE / PLATE CLOSURE 1-1/4" (31,8 1" (25,4 mm) FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. 9/16±1/4" (73,0 mm) 3/4" (19,1 mm) (14,3±6,4 mm) 2-1/4"DIA. 1/4"(6,4m FACE OF (57,2 mm) 1/8 SPRINKLER ________ (3,2 FITTING NG MOUNTING OU SURFACE / PLATE -5/16" (33,3 CLOSURE 13/16"(20,6mm) FIGURE 3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON "FITTING SIDE" TOWARDS SPRINKLER FITTING / WRENCH RECESS / (END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS FIGURE 5 W- TYPE 23 RECESSED SPRINKLER WRENCH Care and Maintenance The Series EC-8 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to TFP223 Page 5 of 6 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must he exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should he made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives, In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- pjes or implied, including warranties of merchantability and fitness for a jcj,tir purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Re- fer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: TY4232, (specify tempera- ture rating), Extended Coverage Pen- dent Sprinkler with (specify finish), P/N (specify). 135°F157°C Natural Brass .............PSN 50-801-1-135 White Coated ... .......... PSN 50-801-4-135 White (RAL9010)*PSN 50-801-3-135 Chrome Plated ............PSN 50-801-9-135 155FI68C Natural Brass ........ ..... PSN 50-801-1-155 White Coated .............PSN 50-801-4-155 White (RAL9010)*PSN 50-801-3-155 Chrome Plated ............PSN 50-801-9-155 *Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style (30 or 40) Recessed Escutcheon with (specify finish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL9O1O). .......... PSN 56-705-3-011 Brass Plated ........ ...... PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700-9-010 White Color Coated ........PSN 56-700-4-010 White (RAL901 0)...........PSN 56-700-3-010 Brass Plated ..............PSN 56-700-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Specify: W-Type 23 Recessed Sprin- kler Wrench, P/N 56-000-6-838. Page 6of6 TFP223 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446