HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; ; AS070180; Permit10/29/2020 AS070180 Permit Data City of Carlsbad Sprinkler Permit 2310 CAMINO VIDA Job Address: ROBLE Permit Type: SPRINK Parcel No: 2130500800 Lot #: 0 Reference No.: Permit No: AS070180 Status: ISSUED Applied 7/12/2007 Approved: 7/24/2007 Issued: 7/24/2007 PC #: Inspector: Project Title: CISCO TI FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: PACIFIC FIRE SUPPRESSION, INC 1642 S. CLEMENTINE ST ANAHEIM, CA 714-502-0211 Owner: R J VIDA ROBLE INVESTORS L L C 2333 STATE ST #200 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 1/1 tqCIY /Fire & Building. I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series EC. Il & EC-14 - 11.2 and 14O K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 M2) for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER 144RN!NG'. that pro vides. cuJinns with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK —T-Y-537-sa-redesgnator.SorC5137, G1894, and S2510. TY5237 is a redesignation for 05237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. oto. Page 2 of 8 TFP22O WRENCH 3/4" ** ESCUTCHEON PLATE FLAT NPT SEATING SURFACE 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT CROSS PENDENT SECTION 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6- Deflector" "Temperature rating is indicated on deflector Pipe thread connections per ISO 7/1 can be provided on special request. 6" nm 6* FIGURE 1 SERIES EC-Il AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHT AND (TY237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB LIQUID NATURAL BRASS i CHROME PLATED I WHITE* 1POLYESTER1 LEAD COATED LIGHT Refer to Table B for Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K11.2 (TY5137) PENDENT K=11.2 (TY5237) K14.0 (TY6237) 135"F/57°C Orange 1,2,3—,4 155°F168°C Red 175°F/79°C Yellow 1,2,4 1,2,4 200"F193"C Green UL and C-UL 286°F/141°C Blue REC. PENDENT K=11.2 (TY5237) K14.0 (TY6237) With Style 30 Escutcheon 135"F/57°C Orange 1, 2,3,4 1, 2,4 N/A 155°F/68"C Red 175°F179"C Yellow 200"F/93"C Green 286°F/141"C Blue ORDINARY Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2 (TY5137) K=14.0 (TY6137) and PENDENT K11.2(TY5237) K=14.0 (TY6237) 135°F157°C Orange 1, 2,3,4 1, 2,3,4 155"F/68°C Red 175°F/79°C Yellow 1, 2, 4 200°F/93°C Green 286°F/141°C Blue REC. PENDENT K=1 1.2 (TY5237) K=14.0 (TY6237) With Style 40 Escutcheon 135°F157"C Orange 1,2,4 N/A 1557F/68°C Red 175°F/79°C Yellow 200°F193"C Green NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL). 21isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the City of New York under MEA 177-03-E. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. *Frame and Deflector only. Listings and approvals apply to color (Special Order). ** Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS TFP220 Page 3of8 LIGHT HAZARD 135°F 155°F 175°F 200°F 286°F ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - OR OR OR OR 14 x 14 Style 30 Recessed - - - - - OR OR OR OR 14 x 14 Style 40 Recessed - - - - - OR OR OR OR 16 x 16 Up. or Pend. QR* QR* QR* QR* QR* SR SR SR SR 16 x 16 Style 30 Recessed QR* QR* QR* QR* QR*. SR SR SR SR 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 18 x 18 Up. or Pend. QR* QR* QR* QR* QR- SR SR' SR SR 18 x 18 Style 30 Recessed QR QR* QR* QR* QR* SR SR SR SR 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 20 x 20 Up. or Pend. QR* QR* QR* SR* SR* SR SR SR SR 20 x 20 Style 30 Recessed QR* SR* OR*. SR* SR* SR SR SR SR 20 x 20 Style 40 Recessed N/A N/A. N/A N/A N/A SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K 14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS (SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. OR* QR* N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR NIA N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. 0R QR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR N/A N/A NIA N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. QR QR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20x20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable * Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 I OR EC-I4 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS) SR N/A N/A SR N/A N/A SR N/A N/A SR N/A N/A Page 4 of 8 TFP220 Finish 2. Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status. The approvals apply to the service conditions indicated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/psi112 (161,3 LPM/bar112) K = 14.0 GPM/ps1112 (201,6 LPM/barl'2) Temperature Ratings 135°F/57°C to 286°F/141°C Physical Characteristics Frame ..............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel wlTeflon 1 Bulb ........Glass (3 mm dia.) Compression Screw ......... .........Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C).. UL and C-UL Listing Requirements The Series EC-1 1 and EC-14 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. The Series EC-1 I and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with a deflector to ceiling/roof deck distance of Ito 12 inches (25 to 300 mm). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of Ito 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-1 I and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses or bar joists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". The minimum allowable spacing be- tween the Series EC-Il and EC-I4 Sprinklers, to prevent cold solder- i8feet(2rn)foruprightsprin- klers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-11 and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6I 37 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above I inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-I4 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, - ..butarenotiimited.to, hydrauUc. design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. TFP22O 2-718" DIA. - 1/2±1/8" (73,0 mm) 112" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER FITTING (3,2 mm) MOUNTING 60MOUNTING SURFACE PLATE CLOSURE/__ 1-3/8"(34,9mm) 1-1/8"(28,6 mm) FIGURE 2 SERIES EC-1 I AND EC-I4 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON Page 5 of 8 "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS / (END -A-) FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - - LLJI WRENCH HEX FIGURE 5 W-TYPE 22 RECESSED SPRINKLER WRENCH 2-7/8" DIA. 518±114" (73,0 mm) 3/4"(19,1 mm (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) I SPRINKLER 1/8" FITTING (3,2 mm) IJ MOUNTING MOUNTING SURFACE PLATE CLOSURE 1-3/8"(34,9 mm 7/8" (22,2 mm) FIGURE .3 SERIES EC-1 I AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON GROUP I ORDINARY HAZARD 0.15 GPM" GPM PSI 30 7.2 .39 12.1 49 19.1 60 28.7 30 7.2 39 12.1 49 19.1 60 28.7 39 7.8 49 12.3 60 18.4 GROUP II ORDINARY HAZARD 0.20 GPMIFT2 GPM PSI 39 12.1 51 20.7 65 33.7 80 51.0 39 12.1 51 20.7 65 33.7 80 51.0 51 13.3 65 21.6 80 32.7 DESCRIPTION TY5137 (K=11.2) UPRIGHT TY5237 (K=11.2) PENDENT 1Y6137 (K=14.0) UPRIGHT LIGHT HAZARD 0.10 GPMIFT2 GPM PSI 30 7.2 33 8.7 40 12.8 30 7.2 33 8.7 40 12.8 NIA N/A N/A N/A N/A N/A N/A N/A AREA 14x 14 16 x 16 18 x 18 20 x 20 14 x 14 16x 16 18x18 20 x 20 14 x 14 16x 16 18 x 18 20 x 20 Page 6 of 8 TFP22O 14x 14 16x16 18 x 18 1Y6237 (K=14.0) PENDENT l ft. =0.3048m 1ft2=0.093m2 I gpm = 3.785 1pm I psi = 0.06895 bar I gpm/ft2 = 40.74 mm/min 37 7.0 39 7.8 51 13.3 37 7.0 49 12.3 65 21.6 40 8.2 60 18.4 80 32.7 TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS Installation Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must The Series EC-11 and EC-14 Sprin- be installed in the pendent position, klers must be installed in accordance and upright sprinklers must be in- with the following instructions: stalled in the upright position. NOTES Step 2. After installing the Style 30 or Do not install any bulb type sprinkler if 40 mounting plate (or other escutch- the bulb is cracked or there is a loss of eon, as applicable) over the sprinkler liquid from the bulb. With the sprinkler pipe threads and with pipe thread held horizontally, a small air bubble sealant applied to the pipe threads, hand tighten the sprinkler into the should be present. The diameter of the air bubble is approximately 1/16 inch sprinkler fitting. (1,6 mm) for the 1350F/570C to 3/32 Step 3. Wrench tighten upright or pen- inch (2,4 mm) for the 2860F/141°C dent sprinklers using only the W-Type temperature ratings. 3 (End A) Sprinkler Wrench. Wrench A leak tight 3/4 inch NPTsprinkler joint tighten the recessed pendent sprin- should be obtained with a torque of 10 klers using only the W-Type 22 Sprin- to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- kler Wrench. The wrench recess of the mum of 30 ft.Ibs. (40.7 Nm) of torque applicable sprinkler wrench (Ref. Fig- is to be used to install sprinklers. ure 4 and 5) is to be applied to the sprinkler-wrench-flats-(.Ref..Eigurei)........- . sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Pl.jte by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP22O Care and Maintenance The Series EC-11 and EC-14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. - - The owner is responsible for thiñ- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFBP shall not be responsi- ble for sprinkler system design errors or inaccurate or incomplete informa- tion supplied by Buyer or Buyers rep- resentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foreaoinciwarrantv is made in lieu press or implied. including warranties of merchantability and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- -- whole or part, of any portion of this warranty will not affect the remainder. Page 8 of 8 Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Re- fer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E. where applicable). Recessed Escutcheon: Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL90IO)*PSN 56-705-3-011 Brass Plated ..............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700-9-010 White Color Coated ........PSN 56-7004-010 White (RAL9O1O). ......... PSN 56-700-3-010 Brass Plated .......... .... PSN 56-700-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 TFP22O P/N 51 - AAA - B -CCC AAA = 893 (for 1Y5237 K11.2 Pendent) AAA = 894 (for 1Y5137 K11.2 Upright) AAA = 895 (for 1Y6237 K14.0 Pendent) MA = 896 (for TY6137 K14.0 Upright) B = I (for Natural Brass) B = 3 (for White [RAL9010]) B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 1350F/570C) CCC = 155 (for 155°F/680C) CCC = 175 (for 175°F/79°C) CCC = 200 (for 200°F/93°C) *Eastem Hemisphere sales only. TABLE E PART NUMBERS FOR EC-11 AND EC-14 SPRINKLERS -1 tqC121,Rre & Building rOducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series 7Y-FRB - 28, 42, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WAP(IINi'" that prividc with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent. Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYI 131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TV21 - Pndnf R.flK /4"NPT 1Y4831- Upright 8.0K, 1/2"NPT 1Y4931- Pendent 8.0K, 1/2"NPT 7/16" 11,1 mm) 1OMINAL MAKE-IN 2-3/16" (55,6 mm) WRENC FLATS 1/2" NPT 6* 5 Page 2 of 10 I ESCUTCHEON 7/16"(11 ,1 mm) I PLATE SEATING NOMINAL SURFACE 1/2 MAKE-IN T-1 — - 2-1/4" NPT (57,2 mm) T= I 1-9/16" (39,7 mm) TFPI7I STYLE 10or20 RECESSED SSu* - ESCUTCHEON DEFLECTOR L 7116" 6 (11,1mm) 4 NOMINAL i MAKE-IN 2 WRENCH $ (55,6 mm) I I 2-3/16" •' 3 FLATS 1/2' NPT I SSP DEFLECTOR * I — 2-7/8" (73,0 mm) DIA PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION -Frame 3-Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT STYLE 10or20 RECESSED ESCUTCHEON ESCUTCHEON 7116"(11,1 mm) PLATE SEATING NOMINAL SURFACE 112" NPT MAKE-IN 2-3/16" (55,6 mm) I I \. 1-1/2" (38,1 mm) SSP DEFLECTOR * h— 2-7/8"(73,0 mm) DIA. SSU* DEFLECTOR PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFPI7I Page 3 of 10 ESCUTCHEON PLATE SEATING SURFACE i 2-3/16" (55,6 mm) f 1-1/2" (38,1 mm) 112" NPT 7116"(11,1 mm) STYLE 10or20 NOMINAL RECESSED MAKE-IN ESCUTCHEON SSU DEFLECTOR 7/16" (11,1 mm) I NOMINAL I 1 i; MAKE-IN 2-3/16" WRENCH FLATS 1/2" NPT t__(55,6 mm) SSP DEFLECTOR * 1-"----- 2-7181(73,0 mm) DIA. 6* 4 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION I - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS £6 K-FACTOR, 1/2 INCH NPT iI CROSS SECTION I - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS &O K-FACTOR, 314 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE-IN (58,7 mm) 1-9/16" (39,7 mm) 1 WRENCH FLATS SSP DEFLECTOR * I 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT STYLE 30 or 40 RECESSED ssu ESCUTCHEON DEFLECTOR 6* 1/2".. (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) Page 4 of 10 TFPI7I 7116"(11,1 mm) NOMINAL SSU MAKE-IN DEFLECTOR 2-1/4" (57,2 mm) 1/2" NPT WRENCH FLATS '...-.- SSP* DEFLECTOR PENDENT 1-Frame 3-Sealing 4-Bulb 6-Deflector 2- Button Assembly 5-Compression Screw CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. -I- FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Usted. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/psil'2 (60,5 LPMIbar112) K = 5.6 GPM/psi112 (80,6 LPMIbar"2) K = 8.0 GPM/p51112 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button ..........Brass/Copper Seslinq-AsembIy - Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design. Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the,requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED WHITE 1POLYESTER 2.8 1/2" PENDENT (7Y1231) and UPRIGHT (TYII3I) 135"F/57°C Orange 1,2,3,5 155°F168"C Red 175"F/79"C Yellow 200" F/93"C Green 2867F1141"C Blue NPT 135"F/57"C Orange 1, 2,5 RECESSED PENDENT (TY1231)" Figure 155°F168"C Red 175°F/79°C Yellow 200"F/93°C Green 135°F/57'C Orange RECESSED PENDENT (IY1231)" Figure 7 155"F/68"C Red 175"F/79"C Yellow 200°F/93"C Green 4.2 1/2" NPT PENDENT Y221) and UPRIGHT (TY2131) 135°F157°C Orange 1,2 155"F168"C Red 175°F/79"C Yellow 200" FI93°C Green 286°F1141"C Blue 135"F/57C Orange RECESSED PENDENT (TY2231)* Figure 8 155°F168°C Red 175°F179°C Yellow 200°F193"C Green 135°F/57°C Orange RECESSED PENDENT (TY2231)" Figure 9 155"F/68°C Red 175"Fff9°C Yellow 200"F/93"C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (112" NPT) or Style 30 3I4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 60f 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED J P OWHITE"" LYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135"F/57°C Orange 1,2,3,4,5,6,7 1,2, 3, 5 15s"F/68°C Red 175" F/79°C Yellow 200°F193°C Green 286°F/141"C Blue NPT 135°F/57"C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231)0 Figure 10 1 55"F/68"C Red 175°F179C Yellow 200"F/93"C Green - 135"F/57"C Orange 1,2,3,4,5 1,2,4,5 N/A RECESSED PENDENT (TY3231)" Figure 11 155°F/68°C Red 175°F/79"C Yellow 200°F193°C Green 8.0 3/4" PENDENT (TY4231) and UPRIGHT (TY4131) 135°F157°C Orange 1,2,3,4,5,6, 7 1, 2, 5 1550 F168°C Red 175"F179"C Yellow 200°F193"C Green 286"F/141"C Blue NPT 135"FI5rC Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)" Figure 12 1"F/68°c Orange 1750 F/79°C Red 200°F/93"C Yellow 135°F/57"C Orange 1,2,3,4,5 N/A RECESSED PENDENT (1Y4231)" Figure 13 155"F/68"C Red 1750 F/79°C Yellow 200"17/93"C Green 8.0 1/2" NPT PENDENT (1Y4931) and UPRIGHT (TY4831) 135"F/57c Orange 1,2, 4, 5,6 1, 2, 5 155"F/68°C Red 175°F/79°C Yellow 200"F/93°C Green 286*F/141*Cl Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. .3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved-(For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. _&.WhereJ?oiystr CnatetandLeadCoate Sprinkler are notedio.beiiLanthCdlL Listedthe..spdnkier !eliLarid CULListed s Corrosion Resistant Sprinklers. Where lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). NIA: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 P81(12,1 BAR) N/A 1l2 RECESSED PENDENT NPT (TY323) PENDENT (1Y4231) and 4.2 UPRIGHT (rY4131) 175 PSI (12,1 BAR) N/A 314 RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 112 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) 3I4 RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (T'4931) 1/? and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if The bulb is cracked or there is loss of liquid from The bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 —r4m)-fr-the-286FI14i-°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40, 7Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening The sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in aecordance-with-the4ollowirig-instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the WLlype 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- ---cabe--over-thesprinker-threads-and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE I \ - MOUNTING SURFACE CLOSURE SERIES CLOSURE SERIES 2-7/8'DIA. (73,0 mm) 3/4' (19,1 mm) 2-1/4' DIA. 1/4' (6,4 mm) I (57,2 mm) MOUNTING I D,Ar I 1/8" I (3,2 mm) t f 1-114"(31.8 mm) I 3/4"(19,1 mm) 2-7/8"DIA. - (73,0 mm) I 1/2"(12,7 mm) 2-1/4'DIA. 1/4"(6,4 mm) (57,2 mm) MOUNTING F-I,I I I (3 j 2mm) I -t 1-1/4"(31,8 mm) 1" (25,4 mm) Page 8 of 10 2-718'DIA. -, (73,0 mm) J 314"(19,1 mm) ' 1/4 (6,4 mm) I 2-1/4'DIA. I (57,2 mm) ;i;-J I MOUNTING I - fllA1t I ( rLnl 1/8' (3,2 mm) MOUNTING "4 . SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16' (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8' DR. - 1/2±1/8' I (73,0 mm) 1/2'(12,7 mm) r (12,7±3,2 mm) 2-1/4' DR. I 1/4" (6,4 mm) I I SPRINKLER I I I - PLATE FACE OF i572 mm) i1 I MOUNTING I FITTING rrr 2mm) 1/8' ( t MOUNT IN,,,, /11 k1k1r SURFACE CLOSURE SE 1-5/16" (33,3 mm) TY-FRB 1-1/16' (27,0 mm) FIGURE 7 SERIES TY-FRB. RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 5/8±1/4' (15,9±6,4 mm) FACE OF SPRINKLER FITTING FIGURE 8 SERIES .TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and MAN- __r - - - vliU&CfIahiVtc The Series TY-FRB Sprinklers must be maintained and sarviced in accord- ance with the following instructions: NOTES Before closing a fire piviaction system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is -used-to cover-a-clearance hole--may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING CLOSURE SERIES I \ - MOUNTING SURFACE CLOSURE SERIES 2-7/8" DIA. (73,0 mm) 3/4"(19,11 mm) 2-1/4" DIA. 1/4" (6,4 mm) I (57,2 mm) ( MOUNTING flIAr ( I I 1/8" I (3,2 mm) t 1-1/4" (31,8 mm) I 3/4" (19,1 mm) 2-718"DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. :1 1/4"(6,4mm) I (57,2 mm) MOUNTING I L:" L (32 m) l C I I f 1-1/4"(311,13 mm) 1" (25,4 mm) TFPI7I Page 90f 10 FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR. 1/2 INCH NPT FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 314"(19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57.2 mm) MOUNTING 01 AIM 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. I 1/4"(6,4 mm) (57,2 mm) 31 MOUNTING I DIAT I MOUNTING SURFACE CLOSURE SERIES TY-FRB 10 1-5116"(33,3 mm) 13/16'(20,6 mm) I \ - MOUNTING SURFACE CLOSURE SERIES TY-FRB 1/8 (32 mm) 1-&16"(33,3 mm 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- jjj"jj, proteco system de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25); in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 TFPI7I P/N 57-XXX-X---XXX I I TEMPERATURE I MODEL/SIN I I SPRINKLER _ L.... RA11NG 330 2.8K UPRIGHT (112NPT) TY1131 11 135 135°F/57C 331 2.8K PENDENT (1/2NPT) TY1231 1 NATURAL BRASS 155 155FI68C 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 175°F179C 341 4.2K PENDENT (1/2NPT) 1Y2231 3 WHITE (RAL90I0)* 200 200FI93C 370 5.6K UPRIGHT (1/2NPT) TY3131 9 CHROME PLATED 286 286°F1141°C 371 5.6K PENDENT (1/2NNPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3I4NPT) 1Y4131 391 8.0K PENDENT (314"NPT) 1Y4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2NPT) 1Y4831 361 8.0K PENDENT (1/2"NPT) TY4931 TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited In no event shall TFBP be liable, in contract, tort, strict liability or under Ordering any other legal theory, for incidental, Procedure Warranty indirect, special or consequential dam- ages, including but not limited to labor Products manufactured by Tyco Fire & charges, regardless of whether TFBP When placing an order, indicate the Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num- ten (10) years against defects in mate- TFBP's liability exceed an amount bers. nat and workmanship when paid for and properly installed and maintained equal to the sales price. Contact your local distributor for avail- under normal use and service. This The foregoing warranty is made in lieu ability. warranty will expire ten (10) years from date of shipment by TFBP. No of any and all other warranties, ex- Sprinkler Assemblies with NPT press or imolied. including warranties warranty is given for products or corn- of merchantability and fitness for a par- Thread Connections: ticular purpose. ponents manufactured by companies not affiliated by ownership with TFBP _______ This limited warranty sets forth the ex- Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB or for products and components which clusive remedy for claims based on (specify Pendent or Upright) Sprinkler have been subject to misuse, improper installation, corrosion, or which have failure of or defect in products, materi- als or components, whether the claim with (specify type of finish or coating), not been installed, maintained, modi- is made in contract, tort, strict liability P/N (specify from Table D). fled or repaired in accordance with ap- plicable Standards of the National Fire or any other legal theory. Recessed Escutcheon: Protection Association, and/or the This warranty will apply to the full ex- tent permitted by law. The invalidity, in Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- standards of any other Authorities Having Jurisdiction. Materials found whole or part, of any portion of this ish, P/N (Specify*). hv TFRP to be dpfprtivp shall be either warranty will not affect the remainder. - repaired or replaced, at TFBPs sole optim._TEBEiieitheLassumes,_nor authorizes any person to assume for it, any other obligation in connection with the sale f products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or mac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentative. ....................... Refer to Technical Data Sheet it-r'iu. SprinkierWrench - Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. tqccyllproducts F/re & Building Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-B - 28.5,6. and 8.0 K-factor Upright, Pendent; and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TV-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10(1/2 inch N PT) or Style 40(3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate Tha fire situation or cause it to operate prematurely. cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII5I - Upright 2.8K, 1/2"NPT TY1251 - Pendent 2.8K, 1/2"NPT TY3151 - Upright 5.6K, 1/2"NPT TY3251 - Pendent 5.6K, 1/2"NPT TY4151 - Upright 8.0K, 3/4"NPT TY4251 - Pendent 8.0K, 3/4"NPT TY4851 - Upright 8.0K, 1/2"NPT TY4951 - Pendent 8.0K, 1/2"NPT :,. SSU* DEFLECTOR 7/16" 11,1 mm) IOMINAL MAKE-IN I 2-3116" (55,6 mm) 6* Page 2 of 8 TFPI 51 ESCUTCHEON 7/16'(11,1 mm) - - PLATE SEATING 1/2" ** NOMINAL SSU SURFACE MAKE-IN DEFLECTOR 2-1/4" NPT zMal _I"wRE t(55,6 NCH 2-3/16" 1 I (57,2 mm) mm) 1-9/16" (39,7 mm) FLATS SSP* DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 -Frame 3-Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) PLATE SEATING 1/2" ** NOMINAL SURFACE MAKE-IN T_ _T i 2-3/16" _ NPT (55,6 mm) f 1-1/2" (38,1 mm) STYLE 10 RECESSED ESCUTCHEON N WRENC FLATS SSP DEFLECTOR* I-"--- 2-7I8" (73,0 mm) DR. PENDENT RECESSED PENDENT 1/2" NPT** UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT ESCUTCHEON 1/2"(12,7 mm) PLATE SEATING ** NOMINAL SURFACE NPT MAKE-IN _F_ 2J16 _ (58, mm) 1-9/16' (39,7 mm) I. STYLE 40 RECESSED ESCUTCHEON N WRENCH FLATS SSP DEFLECTOR I 2-7/8"(73,0 mm) DIA PENDENT RECESSED PENDENT SSU* DEFLECTOR ESCUTCHEON PLATE SEATING SURFACE 7/16(11,1 mm) 112** NOMINAL MAKE-IN NPT -..-.. SSP* DEFLECTOR CROSS SECTION PENDENT UPRIGHT 2-1/4" (57,2 mm) OH S 4 2 TFPI5I Page 3 of 8 SSU * DEFLECTOR I M 2,7 mm) MINAL I AKE-IN 2-1/4" (57,2 mm) 3/4" NPT UPRIGHT CROSS SECTION 1 -Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4151) AND PEND E N T ( T Y 4 2 5 1 ) S P R I N K L E R S 8.0 K-FACTOR, 3/4 INCH NPT - Frame 2- Button 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to Assembly 5 - Compression orifice seat on frame. Screw Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4851) AND P E N D E N T ( T V 4 9 5 1 ) S P R I N K L E R S 8.0 K-FACTOR, 112 INCH NPT Page 4 of 8 TFPI5I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME I WHITE" LEAD I WAX I WAX OVER LIQUID BRASS PLATED JPOLYESTER COATED J COATED J LEAD COATED 135"F157°C Orange 2.8 1/2" PENDENT (TY1251) and Red 1,2,-3 Yellow N/A 155"F/68°C 175°F/79"C NPT UPRIGHT Green it 200°F/93°C (TYII5I)it Blue IN it 286"F/141°C 360"F/1 82"C Mauve 1,2 r 135°F/57"C Orange PENDENT (TY3251) and Red 1,2,3,4,5,6,7 Yellow 1,2,3,5 1,2,3,5 1,2,3,5 155"F/68"C 175°F/79"C UPRIGHT Green 200°17/93°C 5.6 1/2" (TY3151) Blue 286"F1141°C 1—,2—,3—,5— 1", 2, 3", 5 360"F/182"C _____________ N/A NPT Mauve 135°F157"C Orange RECESSED PENDENT (7Y3251)" Red 1,2,3,4,5 Yellow 1,2,4,5 NIA 55- -C 175"F/79°C Figure 4 Green 200"F193"C 286°F/141"C Blue It 1 1,2 it 135"F/57"C Orange It 8.0 PENDENT (TY4251) and UPRIGHT (TY4151) NPT ___ Red 11 it Yellow N it 1,2,3, 4, 5,6, 7 Green Blue 1,2,5 1,2,3,5 1,2,5 155"F/68°C 175°F/79°C 200"F/93"C 286"F/141"C 5" PEE 1",2,5" 360°F1182"C N/A Mauve 135°F/57"C Orange 111 Red 1, 2, 3,4, 5 Yellow N/A RECESSED PENDENT (TY4251)* 155°F/68"C 175°F/79"C Figure 5 Green 200"F193°C 286°F/141"C Blue 1,2 135"F/57°C Orange 8.0 PENDENT (TY4951) Red 155°F/68°C 175°FR9"C 1/2" and Yellow 1,2,3, 5 N/A NPT UPRIGHT (1Y4851) 200"F/93°C Green Blue 286"F/141°C Mauve 360°F/182"C NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the Loss Prevention Certiflcatioi Board (LPCB Ref. No. 007k/03). - VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). Where Polyester Coated, lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. 150°F/66"C Maximum Ceiling Temperature. TABLE A, LABORATORY LISTINGS AND APPROVALS TFPI 51 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 28 PENDENT (TY1251) 112° and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (Ff1151) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2° UPRIGHT (Ff3151) OR NPT 175 PSI (12,1 BAR) RECESSED PENDENT (Ff3251) (SEE NOTE 1) N/A 8.0 PENDENT (Ff4251) 3/4° and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0. PENDENT (Ff4951) 1/2° and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics_ Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector ...........Copper Bushing (K2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TV-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, sobeused_forrecessed.penderit. installations. E (a ------------ -- to-.- I— C) (a (a C,) (a cr2 C, 0 Page 6 of 8 TFPI5I 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 3/4"(19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) i (57,2 mm) :1 MOUNTING / - PLATE WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 314"(19,1 mm) (15,9±6,4 mm) _ 2-1/4" DIA. 1/4"(6,4 mm) (57,2 mm) J FACE OF MOUNTING SPRINKLER I PLATE FITTING 1/8" (3,2 mm) _________ \4 .;;i MOUNTING SURFACE// CLOSURE SERIES 1-5116"(33,3 mm) TV-B 13/16"(20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The Series TV-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360"F/182°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28.5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.Ibs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause MOUNTING SURFACE CLOSURE SS (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH TFPI5I Page 7 of 8 leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series. TV-B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W-Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TV-B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 0r4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TV-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TV-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. by brushing it with a soft bristle brush Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tións should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance Of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES -. On/v retouching of the waxioatinaep- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned ... by wiping the sprinkler with a cloth or Page 8 of 8 TFPI5I TY1251 P/N 57-XXX-X-XXX I I ___ SPRINKLER MODEL/SIN RATING 530 1 2.8K UPRIGHT (1/2NPT) TYI15I F , NATURAL BRASS] 135 I 135F/57°C 590 1 2.8K UPRIGHT (1/2"NPT) 4 WHITE POLYESTER 155 155'F/68°C 570 5.6K UPRIGHT (1/2"NPT) 3 WHITE (RAL9010) * 175 175°F179°C 571 5.6K PENDENT (1/2"NPT) 9 CHROME PLATED 200 200*F/93*C 590 8.0K UPRIGHT (314"NPT) 7 LEAD COATED 286 286°F/141°C 591 8.0K PENDENT (3/4NPT) 6 WAX COATED 360 1 360°F1182°C 2860F/141*C MAX. 560 8.0K UPRIGHT (1/2°NPT) 8 WAX OVER LEAD 561 8.0K PENDENT (1/2NPT) 286°F1141°C MAX. TABLE C PART NUMBER SELECTION SERIES TY-B PENDENTAND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or corn- pónents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any-other-obligation-in-connection-with-- the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. F.T(T.T1iiT0 maT. WFIT41 [FrouiTiTgili1flj1 This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify 10 or 40 ) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001..