HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; ; AS070180; Permit10/29/2020 AS070180 Permit Data
City of Carlsbad
Sprinkler Permit
2310 CAMINO VIDA
Job Address:
ROBLE
Permit Type: SPRINK
Parcel No: 2130500800
Lot #: 0
Reference No.:
Permit No: AS070180
Status: ISSUED
Applied 7/12/2007
Approved: 7/24/2007
Issued: 7/24/2007
PC #: Inspector:
Project Title: CISCO TI FIRE SPRINKLER PLAN CHECK & INSPECTION
Applicant:
PACIFIC FIRE SUPPRESSION, INC
1642 S. CLEMENTINE ST
ANAHEIM, CA
714-502-0211
Owner:
R J VIDA ROBLE INVESTORS L L C
2333 STATE ST #200
CARLSBAD CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
124 0 124 0
1/1
tqCIY /Fire & Building.
I Products
Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500
Series EC. Il & EC-14 - 11.2 and 14O K-factor
Extended Coverage (Light and Ordinary Hazard)
Upright, Pendent, and Rec. Pendent Sprinklers
General
Description
The Series EC-11 and EC-14 Ex-
tended Coverage Upright and Pendent
Sprinklers are decorative glass bulb
sprinklers designed for use in light or
ordinary hazard occupancies. They
are intended for use in automatic
sprinkler systems designed in accord-
ance with standard installation rules
(e.g., NFPA 13) for a maximum cover-
age area of 400 ft2 (37,2 m2), as com-
pared to the maximum coverage area
of 130 ft2 (12,1 M2) for standard cover-
age sprinklers used in ordinary haz-
ard occupancies or 225 ft2 (20,6 m2)
for standard coverage sprinklers used
in light hazard occupancies.
The Series EC-11 and EC-14 Sprin-
klers feature a UL and C-UL Listing
that permits their use with unob-
structed or non-combustible ob-
structed ceiling construction as de-
fined and permitted by NFPA 13, as
well as a specific application listing for
use under concrete tees.
The Series EC-11 and EC-14 Ex-
tended Coverage Sprinklers have
been fire tested to compare their per-
formance to that of standard coverage
spray sprinklers. These tests have
shown that the protection provided is
equal to or more effective than stand-
ard coverage spray sprinklers.
IMPORTANT
Always refer to Technical Data
Sheet TFP 700 for the "INSTALLER
144RN!NG'. that pro vides. cuJinns
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
tained when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these corrosion resistant coatings
for any given corrosive environment.
The effects of ambient temperature,
concentration of chemicals, and
gas/chemical velocity, should be con-
sidered, as a minimum, along with the
corrosive nature of the chemical to
which the sprinklers will be exposed.
WARNINGS
The Series EC-11 and EC-14 Ex-
tended Coverage Sprinklers described
herein must be installed and main-
tained in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Model/Sprinkler
Identification
Number
TY5137 - Upright, 11.2K
TY5237 - Pendent, 11.2K
TY6137 - Upright, 14.0K
TY6237 - Pendent,14.OK
—T-Y-537-sa-redesgnator.SorC5137,
G1894, and S2510.
TY5237 is a redesignation for 05237,
G1893, and S2511.
TY6137 is a redesignation for C6137,
G1896, and S2610.
TY6237 is a redesignation for C6237,
G1895, and S2611.
oto.
Page 2 of 8 TFP22O
WRENCH 3/4" ** ESCUTCHEON PLATE
FLAT NPT SEATING SURFACE
2-7/16"
(61,9 mm)
UPRIGHT &
PENDENT
1/2(12,7mm) J
NOMINAL MAKE-IN
UPRIGHT
CROSS
PENDENT SECTION
1 - Frame
2 - Button
3 - Sealing Assembly
4 - Bulb
5 - Compression Screw
6- Deflector"
"Temperature rating is
indicated on deflector
Pipe thread
connections per ISO
7/1 can be provided
on special request.
6"
nm
6*
FIGURE 1
SERIES EC-Il AND EC-14 EXTENDED COVERAGE SPRINKLERS
11.2 K-FACTOR (TY5137) UPRIGHT AND (TY237) PENDENT
14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT
SPRINKLER FINISH (See Note 5)
HAZARD TYPE TEMP. BULB
LIQUID
NATURAL
BRASS i CHROME
PLATED
I WHITE*
1POLYESTER1
LEAD
COATED
LIGHT
Refer to Table B for
Sensitivity Rating
and
Refer to Table C for
FM
Sensitivity Rating
UPRIGHT
K11.2 (TY5137)
PENDENT
K=11.2 (TY5237)
K14.0 (TY6237)
135"F/57°C Orange
1,2,3—,4 155°F168°C Red
175°F/79°C Yellow
1,2,4 1,2,4 200"F193"C Green
UL and C-UL
286°F/141°C Blue
REC. PENDENT
K=11.2 (TY5237)
K14.0 (TY6237)
With Style 30
Escutcheon
135"F/57°C Orange
1, 2,3,4
1, 2,4
N/A 155°F/68"C Red
175°F179"C Yellow
200"F/93"C Green
286°F/141"C Blue
ORDINARY
Refer to Table B for
UL and C-UL
Sensitivity Rating
and
Refer to Table C for
FM
Sensitivity Rating
UPRIGHT
K=11.2 (TY5137)
K=14.0 (TY6137)
and
PENDENT
K11.2(TY5237)
K=14.0 (TY6237)
135°F157°C Orange
1, 2,3,4
1, 2,3,4 155"F/68°C Red
175°F/79°C Yellow
1, 2, 4 200°F/93°C Green
286°F/141°C Blue
REC. PENDENT
K=1 1.2 (TY5237)
K=14.0 (TY6237)
With Style 40
Escutcheon
135°F157"C Orange
1,2,4 N/A 1557F/68°C Red
175°F/79°C Yellow
200°F193"C Green
NOTES:
1.Listed by Underwriters Laboratories, Inc. (UL).
21isted by Underwriters Laboratories, Inc. for use in Canada (C-UL).
Approved by Factory Mutual Research Corporation (FM).
Approved by the City of New York under MEA 177-03-E.
Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion Resistant Sprinklers.
*Frame and Deflector only. Listings and approvals apply to color (Special Order).
** Pendent Only.
N/A: Not Available
TABLE A, LABORATORY LISTINGS AND APPROVALS
TFP220 Page 3of8
LIGHT HAZARD
135°F 155°F 175°F 200°F 286°F
ORDINARY HAZARD
135°F 155°F 175°F 200°F 286°F
AREA STYLE
14 x 14 Up. or Pend. - - - - - OR OR OR OR
14 x 14 Style 30 Recessed - - - - - OR OR OR OR
14 x 14 Style 40 Recessed - - - - - OR OR OR OR
16 x 16 Up. or Pend. QR* QR* QR* QR* QR* SR SR SR SR
16 x 16 Style 30 Recessed QR* QR* QR* QR* QR*. SR SR SR SR
16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR
18 x 18 Up. or Pend. QR* QR* QR* QR* QR- SR SR' SR SR
18 x 18 Style 30 Recessed QR QR* QR* QR* QR* SR SR SR SR
18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR
20 x 20 Up. or Pend. QR* QR* QR* SR* SR* SR SR SR SR
20 x 20 Style 30 Recessed QR* SR* OR*. SR* SR* SR SR SR SR
20 x 20 Style 40 Recessed N/A N/A. N/A N/A N/A SR SR SR SR
OR: Quick Response
SR: Standard Response
N/A: Not Applicable
* Does not apply to Upright K 14.0
TABLE B
SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS
(SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS)
LIGHT HAZARD ORDINARY HAZARD
135°F 155°F 175F 200°F 286°F 135°F 155°F 175°F 200°F 286°F
AREA STYLE
14 x 14 Up. or Pend. - - - - - SR SR SR SR SR
14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A
14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A
16 x 16 Up. or Pend. OR* QR* N/A N/A N/A SR SR SR SR SR
16 x 16 Style 30 Recessed OR OR NIA N/A N/A N/A N/A N/A N/A N/A
16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
18 x 18 Up. or Pend. 0R QR* N/A N/A N/A SR SR SR SR SR
18 x 18 Style 30 Recessed OR OR N/A N/A NIA N/A N/A N/A N/A N/A
18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
20 x 20 Up. or Pend. QR QR* N/A N/A N/A SR SR SR SR SR
20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A
20x20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
OR: Quick Response
SR: Standard Response
N/A: Not Applicable
* Pendent Only
TABLE C
SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 I OR EC-I4 SPRINKLERS
(SEE FM LOSS PREVENTION DATA SHEET2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS)
SR
N/A
N/A
SR
N/A
N/A
SR
N/A
N/A
SR
N/A
N/A
Page 4 of 8 TFP220
Finish 2.
Sprinkler: Refer to Table A
Recessed Escutcheon: White Coated,
Chrome Plated, and Brass Plated
Technical
Data
Approvals
UL and C-UL Listed. FM Approved.
(Refer to Table A for complete ap-
proval information including corrosion
resistant status. The approvals apply
to the service conditions indicated in
the Design Criteria section.)
Maximum Working Pressure
175 psi (12,1 bar)
Pipe Thread Connection
3/4 inch NPT
Discharge Coefficients
K = 11.2 GPM/psi112
(161,3 LPM/bar112)
K = 14.0 GPM/ps1112
(201,6 LPM/barl'2)
Temperature Ratings
135°F/57°C to 286°F/141°C
Physical Characteristics
Frame ..............Bronze
Button .............Bronze
Sealing Assembly ..........
Beryllium Nickel wlTeflon 1
Bulb ........Glass (3 mm dia.)
Compression Screw .........
.........Bronze
Deflector ............Brass
Patents
U.S.A. Patent Numbers 5,366,022;
5,579,846; 5,584,344; 5,609,211;
5,862,994; and 5,865,256.
Operation
The glass bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, which then allows the
sprinkler to activate and flow water.
Design
Criteria
The Series EC-11 and EC-14 Ex-
tended Coverage Sprinklers must only
be installed in accordance with the ap-
plicable UL and C-UL Listing or FM
Approval requirements as indicated
below. Only the Style 30 or 40 Re-
cessed Escutcheon is to be used for
recessed installation, as applicable
(Ref. Table A, B, and C)..
UL and C-UL Listing
Requirements
The Series EC-1 1 and EC-14 Sprin-
klers may be used for the coverage
areas shown in Table D, based on
maintaining the minimum specified
flow rate as a function of coverage
area and hazard group for all of the
sprinklers in the design area.
The Series EC-1 I and EC-14 Sprin-
klers are permitted to be used with
unobstructed or non-combustible
obstructed ceiling construction as
defined and permitted by NFPA 13.
For example:
Unobstructed, combustible or non-
combustible, ceiling construction
with a deflector to ceiling/roof deck
distance of Ito 12 inches (25 to 300
mm).
Obstructed, non-combustible, ceil-
ing construction with a deflector lo-
cation below structural members of
Ito 6 inches (25 to 150 mm) and a
maximum deflector to ceiling/roof
deck distance of 22 inches (550
mm).
The Series EC-1 I and EC-14 Sprin-
klers having been specifically tested
and listed for non-combustible ob-
structed construction are permitted
to be used within trusses or bar joists
having non-combustible web mem-
bers greater than 1 inch (25.4 mm)
when applying the 4 times obstruc-
tion criteria rule defined under "Ob-
structions to Sprinkler Discharge
Pattern Development".
The minimum allowable spacing be-
tween the Series EC-Il and EC-I4
Sprinklers, to prevent cold solder-
i8feet(2rn)foruprightsprin-
klers and 9 feet (2,7 m) for pendent
sprinklers.
The Series EC-11 and EC-14 Sprin-
klers are to be installed in accord-
ance with all other requirements of
NFPA 13 for extended coverage up-
right and pendent sprinklers. For ex-
ample: obstructions to sprinkler dis-
charge, obstructions to sprinkler
pattern development, obstructions
to prevent sprinkler discharge from
reaching hazard, clearance to stor-
age, etc.
UL and C-UL Specific Application
Listing Requirements For
Installation Under Concrete Tees
The Series EC-11 and EC-14 Ex-
tended Coverage Upright and Pendent
Sprinklers (TY5137, TY5237, TY6I 37
& TY6237) have a UL and C-UL Spe-
cific Application Listing for use under
concrete tees when installed as fol-
lows:
The stems of the concrete tee con-
struction must spaced at less than
7.5 feet (2,3 m) on center but more
than 3 feet (0,9 m) on center. The
depth of the concrete tees must not
exceed 30 inches (762 mm). The
maximum permitted concrete tee
length is 32 feet (9,8 m); however,
where the concrete tee length ex-
ceeds 32 feet (9,8 m), non-combus-
tible baffles, equal in height to the
depth of the tees, can be installed so
that the space between the tees
does not exceed 32 feet (9,8 m) in
length.
The sprinkler deflectors are to be
located in a horizontal plane at or
above I inch (25,4 mm) below the
bottom of the concrete tee stems.
When the sprinkler deflectors are
located higher than a horizontal
plane 1 inch (251,4 mm) beneath the
bottom of the concrete tee stems,
the obstruction to sprinkler dis-
charge criteria requirements of
NFPA 13 for extended coverage up-
right sprinklers applies.
FM Approval
Requirements
The Series EC-11 and EC-I4 Ex-
tended Coverage Sprinklers are to be
installed in accordance with the appli-
cable Factory Mutual Loss Prevention
Data Sheet for limited use in buildings
of specific roof construction and for the
protection of certain specific ordinary
hazard (non-storage and/or non-flam-
mable or combustible liquid) occupan-
cies. Information provided in the FM
Loss Prevention Data Sheets relate to,
- ..butarenotiimited.to, hydrauUc. design,
ceiling slope and obstructions, mini-
mum and maximum allowable spac-
ing, and deflector-to ceiling distance.
These criteria may differ from UL
and/or NFPA criteria, therefore the de-
signer should review and become fa-
miliar with Factory Mutual require-
ments before proceeding with design.
TFP22O
2-718" DIA.
- 1/2±1/8" (73,0 mm) 112" (12,7 mm)
(12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm)
FACE OF (57,2 mm)
SPRINKLER
FITTING (3,2 mm)
MOUNTING 60MOUNTING SURFACE
PLATE
CLOSURE/__
1-3/8"(34,9mm)
1-1/8"(28,6 mm)
FIGURE 2
SERIES EC-1 I AND EC-I4 RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
Page 5 of 8
"FITTING SIDE"
TOWARDS SPRINKLER
FITTING
WRENCH
RECESS /
(END -A-)
FIGURE 4
W-TYPE 3 SPRINKLER
WRENCH
WRENCH
RECESS - -
LLJI
WRENCH
HEX
FIGURE 5
W-TYPE 22 RECESSED
SPRINKLER WRENCH
2-7/8" DIA.
518±114" (73,0 mm) 3/4"(19,1 mm
(15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm)
FACE OF (57,2 mm) I
SPRINKLER 1/8"
FITTING (3,2 mm)
IJ
MOUNTING MOUNTING
SURFACE PLATE
CLOSURE
1-3/8"(34,9 mm
7/8" (22,2 mm)
FIGURE .3
SERIES EC-1 I AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
GROUP I
ORDINARY HAZARD
0.15 GPM"
GPM PSI
30 7.2
.39 12.1
49 19.1
60 28.7
30 7.2
39 12.1
49 19.1
60 28.7
39 7.8
49 12.3
60 18.4
GROUP II
ORDINARY HAZARD
0.20 GPMIFT2
GPM PSI
39 12.1
51 20.7
65 33.7
80 51.0
39 12.1
51 20.7
65 33.7
80 51.0
51 13.3
65 21.6
80 32.7
DESCRIPTION
TY5137 (K=11.2) UPRIGHT
TY5237 (K=11.2) PENDENT
1Y6137 (K=14.0) UPRIGHT
LIGHT HAZARD
0.10 GPMIFT2
GPM PSI
30 7.2
33 8.7
40 12.8
30 7.2
33 8.7
40 12.8
NIA N/A
N/A N/A
N/A N/A
N/A N/A
AREA
14x 14
16 x 16
18 x 18
20 x 20
14 x 14
16x 16
18x18
20 x 20
14 x 14
16x 16
18 x 18
20 x 20
Page 6 of 8 TFP22O
14x 14
16x16
18 x 18
1Y6237 (K=14.0) PENDENT
l ft. =0.3048m
1ft2=0.093m2
I gpm = 3.785 1pm
I psi = 0.06895 bar
I gpm/ft2 = 40.74 mm/min
37 7.0 39 7.8 51 13.3
37 7.0 49 12.3 65 21.6
40 8.2 60 18.4 80 32.7
TABLE D
FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS
Installation Step 1. The sprinkler must be installed
with the deflector parallel to the mount-
ing surface. Pendent sprinklers must
The Series EC-11 and EC-14 Sprin- be installed in the pendent position,
klers must be installed in accordance and upright sprinklers must be in-
with the following instructions: stalled in the upright position.
NOTES Step 2. After installing the Style 30 or
Do not install any bulb type sprinkler if 40 mounting plate (or other escutch-
the bulb is cracked or there is a loss of eon, as applicable) over the sprinkler
liquid from the bulb. With the sprinkler pipe threads and with pipe thread
held horizontally, a small air bubble sealant applied to the pipe threads,
hand tighten the sprinkler into the should be present. The diameter of the
air bubble is approximately 1/16 inch sprinkler fitting.
(1,6 mm) for the 1350F/570C to 3/32 Step 3. Wrench tighten upright or pen-
inch (2,4 mm) for the 2860F/141°C dent sprinklers using only the W-Type
temperature ratings. 3 (End A) Sprinkler Wrench. Wrench
A leak tight 3/4 inch NPTsprinkler joint tighten the recessed pendent sprin-
should be obtained with a torque of 10 klers using only the W-Type 22 Sprin-
to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- kler Wrench. The wrench recess of the
mum of 30 ft.Ibs. (40.7 Nm) of torque applicable sprinkler wrench (Ref. Fig-
is to be used to install sprinklers. ure 4 and 5) is to be applied to the
sprinkler-wrench-flats-(.Ref..Eigurei)........- .
sprinkler inlet with consequent leak-
age or impairment of the sprinkler.
Do not attempt to compensate for in-
sufficient adjustment in an Escutcheon
Pl.jte by under- or over-tightening the
Sprinkler. Readjust the position of the
sprinkler fitting to suit.
stalling contractor or sprinkler manu-
facturer should be contacted relative
to any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
TFP22O
Care and
Maintenance
The Series EC-11 and EC-14 Sprin-
klers must be maintained and serviced
in accordance with the following in-
structions:
NOTE
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection systems must
be obtained from the proper authori-
ties and all personnel who may be
affected by this action must be notified.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
- - The owner is responsible for thiñ-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
Page 7 of 8
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or com-
ponents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor
authorizes any person to assume for
it, any other obligation in connection
with the sale of products or parts of
products. TFBP shall not be responsi-
ble for sprinkler system design errors
or inaccurate or incomplete informa-
tion supplied by Buyer or Buyers rep-
resentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
The foreaoinciwarrantv is made in lieu
press or implied. including warranties
of merchantability and fitness for a
particular ouroose.
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
--
whole or part, of any portion of this
warranty will not affect the remainder.
Page 8 of 8
Ordering
Procedure
When placing an order, indicate the full
product name. Please specify the
Sprinkler Identification Number (SIN),
quantity, and temperature rating. Re-
fer to the Price List for complete listing
of Part Numbers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (specify SIN), (specify K-Fac-
tor), (specify temperature rating),
(specify Pendent or Upright) Extended
Coverage Sprinkler with (specify fin-
ish), P/N (specify - from Table E.
where applicable).
Recessed Escutcheon:
Specify: Style (specify 30 or 40) Re-
cessed Escutcheon with (specify fin-
ish), P/N (specify).
Style 30 Recessed Escutcheon
Chrome Plated ............PSN 56-705-9-011
White Color Coated ........PSN 56-705-4-011 White (RAL90IO)*PSN 56-705-3-011
Brass Plated ..............PSN 56-705-2-011
Style 40 Recessed Escutcheon
Chrome Plated ............PSN 56-700-9-010
White Color Coated ........PSN 56-7004-010
White (RAL9O1O). ......... PSN 56-700-3-010
Brass Plated .......... .... PSN 56-700-2-010
*Eastern Hemisphere sales only.
Sprinkler Wrench:
Specify: W-Type 3 Sprinkler Wrench,
P/N 56-895-1-001
Specify: W-Type 22 Recessed Sprin-
kler Wrench, P/N 56-665-7-001
TFP22O
P/N 51 - AAA - B -CCC
AAA = 893 (for 1Y5237
K11.2 Pendent)
AAA = 894 (for 1Y5137
K11.2 Upright)
AAA = 895 (for 1Y6237
K14.0 Pendent)
MA = 896 (for TY6137
K14.0 Upright)
B = I (for Natural Brass)
B = 3 (for White [RAL9010])
B = 4 (for White Polyester)
B = 7 (for Lead Coated
B = 9 (for Chrome Plated)
CCC = 135 (for 1350F/570C)
CCC = 155 (for 155°F/680C)
CCC = 175 (for 175°F/79°C)
CCC = 200 (for 200°F/93°C)
*Eastem Hemisphere sales only.
TABLE E
PART NUMBERS FOR
EC-11 AND EC-14 SPRINKLERS
-1
tqC121,Rre & Building
rOducts
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
Series 7Y-FRB - 28, 42, 56, and 80 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The Series TY-FRB, 2.8, 4.2, 5.6, and
8.0 K-factor, Upright and Pendent
Sprinklers described in this data sheet
are quick response - standard cover-
age, decorative 3 mm glass bulb type
spray sprinklers designed for use in
light or ordinary hazard, commercial
occupancies such as banks, hotels,
shopping malls, etc.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where ap-
plicable, is intended for use in areas
with a finished ceiling. It uses either a
two-piece Style 10 (1/2 inch NPT) or
Style 40 (3/4 inch NPT) Recessed Es-
cutcheon with 1/2 inch (12,7 mm) of
recessed adjustment or up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendent position, or a two-piece
Style 20 (1/2 inch NPT) or Style 30 (3/4
inch NPT) Recessed Escutcheon with
1/4 inch (6,4 mm) of recessed adjust-
ment or up to 1/2 inch (12,7 mm) of
total adjustment from the flush pen-
dent position. The adjustment pro-
vided by the Recessed Escutcheon re-
duces the accuracy to which the fixed
pipe drops to the sprinklers must be
cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WAP(IINi'" that prividc
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fall
to operate in a fire situation or cause
it to operate prematurely.
tamed when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
An intermediate level versions of the
Series TY-FRB Pendent. Sprinklers
are detailed in Technical Data Sheet
TFP356, and Sprinkler Guards are de-
tailed in Technical Data Sheet TFP780
WARNINGS
The Series TY-FRB Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Model/Sprinkler
Identification
Numbers
TYI 131 - Upright 2.8K, 1/2"NPT
TY1231 - Pendent 2.8K, 1/2"NPT
TY2131 - Upright 4.2K, 1/2"NPT
TY2231 - Pendent 4.2K, 1/2"NPT
TY3131 - Upright 5.6K, 1/2"NPT
TY3231 - Pendent 5.6K, 1/2"NPT
TY4131 - Upright 8.0K, 3/4"NPT
TV21 - Pndnf R.flK /4"NPT
1Y4831- Upright 8.0K, 1/2"NPT
1Y4931- Pendent 8.0K, 1/2"NPT
7/16"
11,1 mm)
1OMINAL
MAKE-IN
2-3/16"
(55,6 mm) WRENC
FLATS
1/2" NPT
6*
5
Page 2 of 10
I ESCUTCHEON 7/16"(11 ,1 mm)
I PLATE SEATING NOMINAL
SURFACE 1/2 MAKE-IN
T-1 — -
2-1/4"
NPT
(57,2 mm) T=
I
1-9/16"
(39,7 mm)
TFPI7I
STYLE 10or20
RECESSED SSu*
- ESCUTCHEON DEFLECTOR
L
7116"
6
(11,1mm) 4 NOMINAL i
MAKE-IN 2
WRENCH $ (55,6 mm)
I
I 2-3/16" •' 3
FLATS
1/2' NPT I SSP DEFLECTOR * I — 2-7/8" (73,0 mm) DIA
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
-Frame 3-Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2- Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
STYLE 10or20
RECESSED
ESCUTCHEON
ESCUTCHEON 7116"(11,1 mm)
PLATE SEATING NOMINAL
SURFACE 112"
NPT MAKE-IN
2-3/16"
(55,6 mm) I I \.
1-1/2"
(38,1 mm)
SSP DEFLECTOR * h— 2-7/8"(73,0 mm) DIA.
SSU*
DEFLECTOR
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2- Button Assembly 5 - Compression orifice seat on frame. Screw
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS
4.2 K-FACTOR, 112 INCH NPT
TFPI7I Page 3 of 10
ESCUTCHEON
PLATE SEATING
SURFACE
i 2-3/16"
(55,6 mm)
f
1-1/2"
(38,1 mm)
112"
NPT
7116"(11,1 mm) STYLE 10or20
NOMINAL RECESSED
MAKE-IN ESCUTCHEON SSU
DEFLECTOR
7/16"
(11,1 mm) I
NOMINAL I 1
i;
MAKE-IN
2-3/16"
WRENCH
FLATS
1/2" NPT t__(55,6 mm) SSP DEFLECTOR * 1-"----- 2-7181(73,0 mm) DIA.
6*
4
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
I - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
£6 K-FACTOR, 1/2 INCH NPT
iI
CROSS SECTION
I - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS
&O K-FACTOR, 314 INCH NPT
ESCUTCHEON 1/2" (12,7 mm)
PLATE SEATING NOMINAL
SURFACE NPT MAKE-IN
(58,7 mm)
1-9/16"
(39,7 mm)
1
WRENCH
FLATS
SSP DEFLECTOR * I 2-7/8" (73,0 mm) DIA. 3/4" NPT
PENDENT RECESSED PENDENT UPRIGHT
STYLE 30 or 40
RECESSED ssu ESCUTCHEON DEFLECTOR
6*
1/2"..
(12,7 mm)
NOMINAL
MAKE-IN
2-1/4"
(57,2 mm)
Page 4 of 10 TFPI7I
7116"(11,1 mm)
NOMINAL SSU
MAKE-IN DEFLECTOR
2-1/4"
(57,2 mm)
1/2"
NPT
WRENCH
FLATS
'...-.- SSP*
DEFLECTOR
PENDENT
1-Frame 3-Sealing 4-Bulb 6-Deflector
2- Button Assembly 5-Compression
Screw
CROSS
UPRIGHT SECTION
* Temperature rating is indicated on deflector or adjacent to
orifice seat on frame.
-I-
FIGURE 5
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS
8.0 K-FACTOR, 1/2 INCH NPT
Technical
Data
Approvals
UL and C-UL Usted.
FM, LPCB, and NYC Approved.
(Refer to Table A and B for complete
approval information including corro-
sion resistant status.)
Maximum Working Pressure
Refer to Table C.
Discharge Coefficient
K = 2.8 GPM/psi112 (40,3 LPM/barl'2)
K = 4.2 GPM/psil'2 (60,5 LPMIbar112)
K = 5.6 GPM/psi112 (80,6 LPMIbar"2)
K = 8.0 GPM/p51112 (115,2 LPM/barl'2)
Temperature Ratings
Refer to Table A and B
Finishes
Sprinkler: Refer to Table A and B.
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated.
Physical Characteristics
Frame .............Bronze
Button ..........Brass/Copper
Seslinq-AsembIy -
Beryllium Nickel w/Teflont
Bulb ...............Glass
Compression Screw .....Bronze
Deflector .......Copper/Bronze
Bushing (K=2.8) .......Bronze
Operation
The glass Bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design.
Criteria
The Series TY-FRB Pendent and Up-
right Sprinklers are intended for fire
protection systems designed in ac-
cordance with the standard installation
rules recognized by the applicable
Listing or Approval agency (e.g., UL
Listing is based on the,requirements of
NFPA 13, and FM Approval is based
on the requirements of FM's Loss Pre-
vention Data Sheets). Only the Style
10, 20, 30, or 40 Recessed Escutch-
eon, as applicable, is to be used for
recessed pendent installations.
TFPI7I
SPRINKLER FINISH (See Note 7)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
I CHROME
PLATED
WHITE
1POLYESTER
2.8
1/2"
PENDENT
(7Y1231)
and
UPRIGHT
(TYII3I)
135"F/57°C Orange
1,2,3,5
155°F168"C Red
175"F/79"C Yellow
200" F/93"C Green
2867F1141"C Blue
NPT 135"F/57"C Orange
1, 2,5
RECESSED
PENDENT
(TY1231)"
Figure
155°F168"C Red
175°F/79°C Yellow
200"F/93°C Green
135°F/57'C Orange
RECESSED
PENDENT
(IY1231)"
Figure 7
155"F/68"C Red
175"F/79"C Yellow
200°F/93"C Green
4.2
1/2"
NPT
PENDENT
Y221)
and
UPRIGHT
(TY2131)
135°F157°C Orange
1,2
155"F168"C Red
175°F/79"C Yellow
200" FI93°C Green
286°F1141"C Blue
135"F/57C Orange
RECESSED
PENDENT
(TY2231)*
Figure 8
155°F168°C Red
175°F179°C Yellow
200°F193"C Green
135°F/57°C Orange
RECESSED
PENDENT
(TY2231)"
Figure 9
155"F/68°C Red
175"Fff9°C Yellow
200"F/93"C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re-
sponse Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin-
klers.
5. Approved by the City of New York under MEA 354-01-E.
7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin-
klers are UL and C-UL listed as Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2" NPT) or Style 40 3/4" NPT) 3/4" Total Adjustment
Recessed Escutcheon, as applicable.
Installed with Style 20 (112" NPT) or Style 30 3I4" NPT) 1/2" Total Adjustment
Recessed Escutcheon, as applicable.
Frame and Deflector only. listings and approvals apply to color (Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
Page 5 of 10
Page 60f 10 TFPI7I
SPRINKLER FINISH (See Note 8)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
I CHROME
PLATED
J
P
OWHITE""
LYESTER
LEAD
COATED
5.6
1/2"
PENDENT
(TY3231)
and
UPRIGHT
(TY3131)
135"F/57°C Orange
1,2,3,4,5,6,7 1,2, 3, 5
15s"F/68°C Red
175" F/79°C Yellow
200°F193°C Green
286°F/141"C Blue
NPT 135°F/57"C Orange
1,2,4,5 N/A
RECESSED
PENDENT
(TY3231)0
Figure 10
1 55"F/68"C Red
175°F179C Yellow
200"F/93"C Green
-
135"F/57"C Orange
1,2,3,4,5 1,2,4,5 N/A
RECESSED
PENDENT
(TY3231)"
Figure 11
155°F/68°C Red
175°F/79"C Yellow
200°F193°C Green
8.0
3/4"
PENDENT
(TY4231)
and
UPRIGHT
(TY4131)
135°F157°C Orange
1,2,3,4,5,6, 7
1, 2, 5
1550 F168°C Red
175"F179"C Yellow
200°F193"C Green
286"F/141"C Blue
NPT 135"FI5rC Green
1,2,4,5 N/A
RECESSED
PENDENT
(TY4231)"
Figure 12
1"F/68°c Orange
1750 F/79°C Red
200°F/93"C Yellow
135°F/57"C Orange
1,2,3,4,5 N/A
RECESSED
PENDENT
(1Y4231)"
Figure 13
155"F/68"C Red
1750 F/79°C Yellow
200"17/93"C Green
8.0
1/2"
NPT
PENDENT
(1Y4931)
and
UPRIGHT
(TY4831)
135"F/57c Orange
1,2, 4, 5,6
1, 2, 5 155"F/68°C Red
175°F/79°C Yellow
200"F/93°C Green
286*F/141*Cl Blue
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers.
.3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the
LPCB does not rate the thermal sensitivity of recessed sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved-(For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377).
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers.
_&.WhereJ?oiystr CnatetandLeadCoate Sprinkler are notedio.beiiLanthCdlL Listedthe..spdnkier !eliLarid CULListed s
Corrosion Resistant Sprinklers. Where lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a
Corrosion Resistant Sprinklers.
Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to color (Special Order).
NIA: Not Available
TABLE B
LABORATORY LISTINGS AND APPROVALS
5.6 AND 8.0 K-FACTOR SPRINKLERS
TFPI7I Page 7 of 10
SPRINKLER FINISH
K TYPE NATURAL CHROME WHITE LEAD
BRASS PLATED POLYESTER
I
COATED
PENDENT (TY3231)
and
2.8 UPRIGHT (TY3131) 175 P81(12,1 BAR) N/A
1l2 RECESSED PENDENT NPT (TY323)
PENDENT (1Y4231)
and
4.2 UPRIGHT (rY4131) 175 PSI (12,1 BAR) N/A
314 RECESSED PENDENT NPT (TY4231)
PENDENT (TY3231)
and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR)
5.6 UPRIGHT (TY3131) OR
112 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A
PENDENT (TY4231)
and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR)
8.0 UPRIGHT (1Y4131)
3I4 RECESSED PENDENT NPT (TY4231) N/A
8.0 PENDENT (T'4931)
1/? and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR)
NPT UPRIGHT (1Y4831)
NOTES:
1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by
Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York.
TABLE C, MAXIMUM WORKING PRESSURE
Installation
The Series TY-FRB Sprinklers must
be installed in accordance with the fol-
lowing instructions:
NOTES
Do not install any bulb type sprinkler if
The bulb is cracked or there is loss of
liquid from The bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/570C to 3/32
—r4m)-fr-the-286FI14i-°C
temperature ratings.
A leak tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28,5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 ft.lbs.
(13,4 to 26,8 Nm). A maximum of 30
ft.lbs. (40, 7Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening The
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-FRB Pendent and Up-
right Sprinklers must be installed in
aecordance-with-the4ollowirig-instruc-
tions.
Step 1. Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the WLlype
6 Sprinkler Wrench (Ref. Figure 14).
With reference to Figures 1, 2, 3, 4,
and 5, the W-Type 6 Sprinkler Wrench
is to be applied to the sprinkler wrench
flats.
The Series TY-FRB Recessed Pen-
dent Sprinklers must be installed in
accordance with the following instruc-
tions.
Step A. After installing the Style 10.
20, 30, or 40 Mounting Plate, as appli-
---cabe--over-thesprinker-threads-and
with pipe thread sealant applied to the
pipe threads, hand tighten the sprin-
kler into the sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 15). With reference to Figure 1,
2, 3, and 4, the W-Type 7 Recessed
5/8±1/4'
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
1/2±1/8'
(12,7±3,2 mm)
FACE OF
SPRINKLER
FITTING
MOUNTING
SURFACE
I \ -
MOUNTING
SURFACE
CLOSURE SERIES CLOSURE SERIES
2-7/8'DIA.
(73,0 mm) 3/4' (19,1 mm)
2-1/4' DIA. 1/4' (6,4 mm) I
(57,2 mm) MOUNTING I D,Ar I
1/8" I
(3,2 mm)
t f
1-114"(31.8 mm) I
3/4"(19,1 mm)
2-7/8"DIA. - (73,0 mm) I 1/2"(12,7 mm)
2-1/4'DIA. 1/4"(6,4 mm)
(57,2 mm) MOUNTING
F-I,I I I
(3
j
2mm) I
-t
1-1/4"(31,8 mm)
1" (25,4 mm)
Page 8 of 10
2-718'DIA. -,
(73,0 mm) J 314"(19,1 mm)
' 1/4 (6,4 mm) I 2-1/4'DIA. I (57,2 mm) ;i;-J I MOUNTING I
- fllA1t I ( rLnl
1/8'
(3,2 mm)
MOUNTING "4 .
SURFACE
CLOSURE SERIES 1-5/16" (33,3 mm)
TY-FRB 13/16' (20,6 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
TFPI7I
- 2-7/8' DR. -
1/2±1/8' I (73,0 mm) 1/2'(12,7 mm) r (12,7±3,2 mm) 2-1/4' DR. I 1/4" (6,4 mm) I
I SPRINKLER I I I - PLATE
FACE OF
i572 mm)
i1 I MOUNTING
I FITTING rrr 2mm)
1/8'
(
t MOUNT
IN,,,,
/11 k1k1r
SURFACE
CLOSURE SE 1-5/16" (33,3 mm)
TY-FRB 1-1/16' (27,0 mm)
FIGURE 7
SERIES TY-FRB. RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
5/8±1/4'
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
FIGURE 8
SERIES .TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
Sprinkler Wrench is to be applied to
the sprinkler wrench flats.
Step C. After the ceiling has been in-
stalled or the finish coat has been ap-
plied, slide on the Style 10, 20, 30, or
40 Closure over the Series TY-FRB
Sprinkler and push the Closure over
the Mounting Plate until its flange
comes in contact with the ceiling.
Care and
MAN- __r - - - vliU&CfIahiVtc
The Series TY-FRB Sprinklers must
be maintained and sarviced in accord-
ance with the following instructions:
NOTES
Before closing a fire piviaction system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
The owner must assure that the sprin-
klers are not used for hanging of any
objects; otherwise, non-operation in
the event of a fire or inadvertent opera-
tion may result.
Absence of an escutcheon, which is
-used-to cover-a-clearance hole--may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been corn-
5/8±1/4"
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
MOUNTING
SURFACE
1/2±1/8"
(12,7±3,2 mm)
FACE OF
SPRINKLER
FITTING
CLOSURE SERIES
I \ -
MOUNTING
SURFACE
CLOSURE SERIES
2-7/8" DIA.
(73,0 mm) 3/4"(19,11 mm)
2-1/4" DIA. 1/4" (6,4 mm) I
(57,2 mm) ( MOUNTING
flIAr ( I I
1/8" I
(3,2 mm)
t
1-1/4" (31,8 mm) I
3/4" (19,1 mm)
2-718"DIA.
(73,0 mm) 1/2" (12,7 mm)
2-1/4" DIA. :1 1/4"(6,4mm) I
(57,2 mm) MOUNTING I
L:" L
(32 m)
l C I
I f
1-1/4"(311,13 mm)
1" (25,4 mm)
TFPI7I Page 90f 10
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR. 1/2 INCH NPT
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
5/8±1/4"
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
2-7/8" DIA.
(73,0 mm) 314"(19,1 mm)
2-1/4" DIA. 1/4" (6,4 mm)
(57.2 mm) MOUNTING
01 AIM
1/2±1/8"
(12,7±3,2 mm)
FACE OF
SPRINKLER
FITTING
2-7/8" DIA.
(73,0 mm) 1/2" (12,7 mm)
2-1/4" DIA. I 1/4"(6,4 mm)
(57,2 mm) 31 MOUNTING I
DIAT I
MOUNTING
SURFACE
CLOSURE SERIES
TY-FRB
10
1-5116"(33,3 mm)
13/16'(20,6 mm)
I \ -
MOUNTING
SURFACE
CLOSURE SERIES
TY-FRB
1/8
(32 mm)
1-&16"(33,3 mm
1-1/16" (27,0 mm)
FIGURE 12
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
FIGURE 13
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
jjj"jj, proteco system de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25); in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 14
WRENCH
facturer should be contacted relative
to any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
WRENCH
RECESS
PUSH WRENCH
INTO ENSURE
ENGAGEMENT
WITH SPRINKLER
FIGURE 15
W-TYPE 7 RECESSED
SPRINKLER WRENCH
Inspection Service in accordance with
local requirements and/or national
codes.
Page 10 of 10 TFPI7I
P/N 57-XXX-X---XXX
I I TEMPERATURE I MODEL/SIN I I SPRINKLER _ L....
RA11NG
330 2.8K UPRIGHT (112NPT) TY1131 11 135 135°F/57C
331 2.8K PENDENT (1/2NPT) TY1231 1 NATURAL BRASS 155 155FI68C
340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 175°F179C
341 4.2K PENDENT (1/2NPT) 1Y2231 3 WHITE (RAL90I0)* 200 200FI93C
370 5.6K UPRIGHT (1/2NPT) TY3131 9 CHROME PLATED 286 286°F1141°C
371 5.6K PENDENT (1/2NNPT) TY3231 7 LEAD COATED
390 8.0K UPRIGHT (3I4NPT) 1Y4131
391 8.0K PENDENT (314"NPT) 1Y4231 * Eastern Hemisphere sales only.
360 8.0K UPRIGHT (1/2NPT) 1Y4831
361 8.0K PENDENT (1/2"NPT) TY4931
TABLED
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
Limited In no event shall TFBP be liable, in
contract, tort, strict liability or under Ordering
any other legal theory, for incidental, Procedure Warranty indirect, special or consequential dam-
ages, including but not limited to labor
Products manufactured by Tyco Fire & charges, regardless of whether TFBP When placing an order, indicate the
Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price
ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num-
ten (10) years against defects in mate- TFBP's liability exceed an amount bers.
nat and workmanship when paid for
and properly installed and maintained equal to the sales price. Contact your local distributor for avail-
under normal use and service. This The foregoing warranty is made in lieu ability.
warranty will expire ten (10) years
from date of shipment by TFBP. No
of any and all other warranties, ex- Sprinkler Assemblies with NPT press or imolied. including warranties
warranty is given for products or corn- of merchantability and fitness for a par- Thread Connections:
ticular purpose. ponents manufactured by companies
not affiliated by ownership with TFBP
_______
This limited warranty sets forth the ex-
Specify: (Specify Model/SIN), Quick
Response, (specify K-factor), (specify
temperature rating), Series TY-FRB or for products and components which clusive remedy for claims based on (specify Pendent or Upright) Sprinkler have been subject to misuse, improper
installation, corrosion, or which have failure of or defect in products, materi-
als or components, whether the claim with (specify type of finish or coating),
not been installed, maintained, modi- is made in contract, tort, strict liability P/N (specify from Table D).
fled or repaired in accordance with ap-
plicable Standards of the National Fire
or any other legal theory. Recessed Escutcheon:
Protection Association, and/or the This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
Specify: Style (10, 20, 30, or 40) Re-
cessed Escutcheon with (specify*) fin- standards of any other Authorities
Having Jurisdiction. Materials found whole or part, of any portion of this ish, P/N (Specify*).
hv TFRP to be dpfprtivp shall be either warranty will not affect the remainder. -
repaired or replaced, at TFBPs sole
optim._TEBEiieitheLassumes,_nor
authorizes any person to assume for it,
any other obligation in connection with
the sale f products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or mac-
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentative.
.......................
Refer to Technical Data Sheet it-r'iu.
SprinkierWrench
-
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
tqccyllproducts
F/re & Building
Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500
Series TY-B - 28.5,6. and 8.0 K-factor
Upright, Pendent; and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
General
Description
The Series TV-B, 2.8, 5.6, and 8.0
K-factor, Upright and Pendent Sprin-
klers described in this data sheet are
standard response - standard cover-
age, decorative 5 mm glass bulb type
spray sprinklers designed for use in
light, ordinary, or extra hazard, com-
mercial occupancies such as banks,
hotels, shopping malls, factories, refin-
eries, chemical plants, etc.
The recessed version of the Series
TV-B Pendent Sprinkler, where appli-
cable, is intended for use in areas with
a finished ceiling. It uses a two-piece
Style 10(1/2 inch N PT) or Style 40(3/4
inch NPT) Recessed Escutcheon. The
Recessed Escutcheon provides 1/2
inch (12,7 mm) of recessed adjust-
ment or up to 3/4 inch (19,1 mm) of
total adjustment from the flush pen-
dent position. The adjustment pro-
vided by the Recessed Escutcheon re-
duces the accuracy to which the fixed
pipe drops to the sprinklers must be
cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
tained when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fall
to operate Tha fire situation or cause
it to operate prematurely.
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
An intermediate level version of the
Series TV-B Pendent Sprinkler can be
obtained by utilizing the Series TV-B
Pendent Sprinkler in combination with
the Model S2 Shield.
WARNINGS
The Series TY-B Sprinklers described
herein must be installed and main-
tained in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Model/Sprinkler
Identification
Numbers
TYII5I - Upright 2.8K, 1/2"NPT
TY1251 - Pendent 2.8K, 1/2"NPT
TY3151 - Upright 5.6K, 1/2"NPT
TY3251 - Pendent 5.6K, 1/2"NPT
TY4151 - Upright 8.0K, 3/4"NPT
TY4251 - Pendent 8.0K, 3/4"NPT
TY4851 - Upright 8.0K, 1/2"NPT
TY4951 - Pendent 8.0K, 1/2"NPT
:,.
SSU*
DEFLECTOR
7/16"
11,1 mm)
IOMINAL
MAKE-IN
I 2-3116"
(55,6 mm)
6*
Page 2 of 8 TFPI 51
ESCUTCHEON 7/16'(11,1 mm) - -
PLATE SEATING 1/2" ** NOMINAL SSU
SURFACE MAKE-IN DEFLECTOR
2-1/4"
NPT
zMal
_I"wRE
t(55,6
NCH
2-3/16" 1 I
(57,2 mm) mm)
1-9/16"
(39,7 mm) FLATS
SSP*
DEFLECTOR CROSS
PENDENT UPRIGHT SECTION
1 -Frame 3-Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 1
STANDARD RESPONSE SERIES TY-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
ESCUTCHEON 7/16"(11,1 mm)
PLATE SEATING 1/2" ** NOMINAL
SURFACE MAKE-IN
T_ _T i 2-3/16" _
NPT
(55,6 mm) f
1-1/2"
(38,1 mm)
STYLE 10
RECESSED
ESCUTCHEON
N
WRENC
FLATS
SSP DEFLECTOR* I-"--- 2-7I8" (73,0 mm) DR.
PENDENT RECESSED PENDENT
1/2" NPT**
UPRIGHT CROSS SECTION
- Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
STANDARD RESPONSE SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS
5.6 K-FACTOR, 112 INCH NPT
ESCUTCHEON 1/2"(12,7 mm) PLATE SEATING ** NOMINAL SURFACE
NPT MAKE-IN
_F_
2J16 _ (58, mm)
1-9/16'
(39,7 mm)
I.
STYLE 40
RECESSED
ESCUTCHEON
N
WRENCH
FLATS
SSP DEFLECTOR I 2-7/8"(73,0 mm) DIA
PENDENT RECESSED PENDENT
SSU*
DEFLECTOR
ESCUTCHEON
PLATE SEATING
SURFACE
7/16(11,1 mm)
112** NOMINAL
MAKE-IN NPT
-..-.. SSP*
DEFLECTOR CROSS
SECTION PENDENT UPRIGHT
2-1/4"
(57,2 mm)
OH
S
4
2
TFPI5I
Page 3 of 8
SSU *
DEFLECTOR
I
M
2,7 mm)
MINAL I AKE-IN
2-1/4"
(57,2 mm)
3/4" NPT
UPRIGHT CROSS SECTION
1 -Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw
**Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 3 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4151) AND PEND
E
N
T
(
T
Y
4
2
5
1
)
S
P
R
I
N
K
L
E
R
S
8.0 K-FACTOR, 3/4 INCH NPT
- Frame
2- Button 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to Assembly 5 - Compression orifice seat on frame. Screw
Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 4 STANDARD RESPONSE SERIES TV-B UPRIGHT (TY4851) AND P
E
N
D
E
N
T
(
T
V
4
9
5
1
)
S
P
R
I
N
K
L
E
R
S
8.0 K-FACTOR, 112 INCH NPT
Page 4 of 8 TFPI5I
SPRINKLER FINISH (See Note 8)
K TYPE TEMP. BULB NATURAL I CHROME I WHITE" LEAD I WAX I WAX OVER
LIQUID BRASS PLATED JPOLYESTER COATED
J
COATED
J
LEAD COATED
135"F157°C Orange
2.8
1/2"
PENDENT
(TY1251)
and
Red
1,2,-3 Yellow N/A
155"F/68°C
175°F/79"C
NPT UPRIGHT Green it 200°F/93°C (TYII5I)it
Blue IN it 286"F/141°C
360"F/1 82"C Mauve 1,2
r 135°F/57"C Orange
PENDENT
(TY3251)
and
Red
1,2,3,4,5,6,7 Yellow 1,2,3,5 1,2,3,5 1,2,3,5
155"F/68"C
175°F/79"C
UPRIGHT Green 200°17/93°C
5.6
1/2"
(TY3151)
Blue 286"F1141°C 1—,2—,3—,5— 1", 2, 3", 5
360"F/182"C _____________
N/A NPT Mauve
135°F157"C Orange
RECESSED
PENDENT
(7Y3251)"
Red
1,2,3,4,5 Yellow 1,2,4,5 NIA
55- -C
175"F/79°C
Figure 4 Green 200"F193"C
286°F/141"C Blue It 1 1,2 it
135"F/57"C Orange It
8.0
PENDENT
(TY4251)
and
UPRIGHT
(TY4151)
NPT ___
Red 11 it
Yellow N it 1,2,3, 4, 5,6, 7
Green
Blue
1,2,5 1,2,3,5 1,2,5
155"F/68°C
175°F/79°C
200"F/93"C
286"F/141"C 5"
PEE
1",2,5"
360°F1182"C N/A Mauve
135°F/57"C Orange 111
Red
1, 2, 3,4, 5 Yellow N/A
RECESSED
PENDENT
(TY4251)*
155°F/68"C
175°F/79"C
Figure 5 Green 200"F193°C
286°F/141"C Blue 1,2
135"F/57°C Orange
8.0
PENDENT
(TY4951) Red 155°F/68°C
175°FR9"C 1/2" and Yellow 1,2,3, 5 N/A
NPT UPRIGHT
(1Y4851)
200"F/93°C Green
Blue 286"F/141°C
Mauve 360°F/182"C
NOTES:
Listed by Underwriters Laboratories, Inc. (UL).
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
Approved by Factory Mutual Research Corporation (FM).
Approved by the Loss Prevention Certiflcatioi Board (LPCB Ref. No. 007k/03).
-
VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377).
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05).
Where Polyester Coated, lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the
sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated
Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable.
150°F/66"C Maximum Ceiling Temperature.
TABLE A, LABORATORY LISTINGS AND APPROVALS
TFPI 51 Page 5 of 8
SPRINKLER FINISH
K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER
BRASS PLATED POLYESTER COATED COATED LEAD COATED
28 PENDENT (TY1251)
112° and 175 PSI (12,1 BAR) N/A
NPT UPRIGHT (Ff1151)
PENDENT (TY3251)
5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR)
1/2° UPRIGHT (Ff3151) OR
NPT 175 PSI (12,1 BAR) RECESSED PENDENT
(Ff3251) (SEE NOTE 1) N/A
8.0 PENDENT (Ff4251)
3/4° and 175 PSI (12,1 BAR)
NPT UPRIGHT (TY4151)
RECESSED PENDENT
(TY4251) 175 PSI (12,1 BAR) N/A
8.0. PENDENT (Ff4951)
1/2° and 175 PSI (12,1 BAR)
NPT UPRIGHT (TY4851)
NOTE:
1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by
Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York.
TABLE B, MAXIMUM WORKING PRESSURE
Technical
Data
Approvals
UL and C-UL Listed.
FM, LPCB, VdS, and NYC Approved.
(Refer to Table A for complete ap-
proval information including corrosion
resistant status.)
Maximum Working Pressure
Refer to Table B.
Discharge Coefficient
K = 2.8 GPM/psi112 (40,3 LPM/bar112)
K = 5.6 GPM/psi112 (80,6 LPM/bar112)
K = 8.0 GPM/psi112 (115,2 LPM/barll2)
Temperature Ratings
Refer to Table A.
Finishes
Sprinkler: Refer to Table A.
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated.
Physical Characteristics_
Frame .............Bronze
Button .........Brass/Copper
Sealing Assembly ..........
Beryllium Nickel w/Teflont
Bulb ...............Glass
Compression Screw .....Bronze
Deflector ...........Copper
Bushing (K2.8) .......Bronze
Operation
The glass Bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The Series TV-B Pendent and Upright
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules rec-
ognized by the applicable Listing or
Approval agency (e.g., UL Listing is
based on the requirements of NFPA
13, and FM Approval is based on the
requirements of FM's Loss Prevention
Data Sheets). Only the Style 10 or 40
Recessed Escutcheon, as applicable,
sobeused_forrecessed.penderit.
installations.
E (a
------------ -- to-.-
I—
C)
(a
(a
C,) (a cr2
C, 0
Page 6 of 8 TFPI5I
5/8±1/4"
(15,9±6,4 mm)
FACE OF
SPRINKLER
FITTING
2-7/8" DIA.
(73,0 mm) 3/4"(19,1 mm)
2-1/4" DIA. 1/4" (6,4 mm) i
(57,2 mm) :1 MOUNTING / - PLATE
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
FIGURE 5
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
2-7/8" DIA.
5/8±1/4" (73,0 mm) 314"(19,1 mm)
(15,9±6,4 mm) _ 2-1/4" DIA. 1/4"(6,4 mm)
(57,2 mm) J FACE OF MOUNTING
SPRINKLER I PLATE
FITTING
1/8"
(3,2 mm)
_________
\4
.;;i MOUNTING
SURFACE//
CLOSURE SERIES 1-5116"(33,3 mm)
TV-B 13/16"(20,6 mm)
FIGURE 6
SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 8
W-TYPE 7 RECESSED
SPRINKLER WRENCH
Installation
The Series TV-B Sprinklers must be
installed in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type sprinkler if
the bulb is cracked or there is a loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/57°C to 3/32
inch (2,4 mm) for the 360"F/182°C
temperature ratings.
A leak tight 1/2 inch NPT sprinklerjoint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28.5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 ft.Ibs.
(13,4 to 26,8 Nm). A maximum of 30
ft.lbs. (40,7 Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
MOUNTING
SURFACE
CLOSURE SS
(3,2 mm)
1-1/4"(31,8 mm)
3/4"(19,1 mm)
WRENCH RECESS
(END "B" USED FOR
3/4" NPT MODELS)
FIGURE 7
W-TYPE 6 SPRINKLER
WRENCH
TFPI5I Page 7 of 8
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series. TV-B Pendent and Up-
right Sprinklers must be installed in
accordance with the following instruc-
tions.
Step 1. Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 7),
except that an 8 or 10 inch adjustable
Crescent wrench is to be used for wax
coated sprinklers. With reference to
Figures 1, 2, 3, and 4 the W-Type 7
Sprinkler Wrench or the adjustable
Crescent wrench, as applicable is to
be applied to the wrench flats.
When installing wax coated sprinklers
with the adjustable Crescent wrench,
additional care needs to be exercised
to prevent damage to the wax coating
on the sprinkler wrench flats or frame
arms and, consequently, exposure of
bare metal to the corrosive environ-
ment. The jaws of the wrench should
be opened sufficiently wide to pass
over the wrench flats without damag-
ing the wax coating. Before wrench
tightening the sprinkler, the jaws of the
wrench are to be adjusted to just con-
tact the sprinkler wrench flats. After
wrench tightening the sprinkler, loosen
the wrench jaws before removing the
wrench.
After installation, the sprinkler wrench
flats and frame arms must be in-
spected and the wax coating re-
touched (repaired) whenever the coat-
ing has been damaged and bare metal
is exposed. The wax coating on the
wrench flats can be retouched by gen-
tly applying a heated 1/8 inch diameter
steel rod to the areas of wax that have
been damaged, to smooth it back over
areas where bare metal is exposed.
The steel rod should be heated only to
the point at which it can begin to melt
the wax, and appropriate precautions
need to be taken, when handling the
heated rod, in order to prevent the
installer from being burned.
The Series TV-B Recessed Pendent
Sprinklers must be installed in ac-
cordance with the following instruc-
tions.
Step A. After installing the Style 10 or
40 Mounting Plate as applicable, over
the sprinkler threads and with pipe
thread sealant applied to the pipe
threads, hand tighten the sprinkler into
the sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 8). With reference to Figure 3
0r4, the W-Type 7 Recessed Sprinkler
Wrench is to be applied to the sprinkler
wrench flats.
Step C. After the ceiling has been in-
stalled or the finish coat has been ap-
plied, slide on the Style 10 or 40 Clo-
sure over the Series TV-B Sprinkler
and push the Closure over the Mount-
ing Plate until its flange comes in con-
tact with the ceiling.
Care and
Maintenance
The Series TV-B Sprinklers must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
The owner must assure that the sprin-
klers are not used for hanging of any
objects; otherwise, non-operation in
the event of a fire or inadvertent opera-
tion may result.
Absence of an escutcheon, which is
used to cover a clearance hole, may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
by brushing it with a soft bristle brush
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tións should be made, so as to better
determine the exact sprinkler condi-
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
spection, testing, and maintenance Of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative
to any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service in accordance with
local requirements and/or national
codes.
NOTES
-. On/v retouching of the waxioatinaep-
plied to the wrench flats and frame
arms is permitted, and the retouching
is to be performed only at the time of
the initial sprinkler installation.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned ...
by wiping the sprinkler with a cloth or
Page 8 of 8 TFPI5I
TY1251 P/N 57-XXX-X-XXX
I I ___
SPRINKLER
MODEL/SIN RATING
530 1 2.8K UPRIGHT (1/2NPT) TYI15I F , NATURAL BRASS] 135 I 135F/57°C
590 1 2.8K UPRIGHT (1/2"NPT) 4 WHITE POLYESTER 155 155'F/68°C
570 5.6K UPRIGHT (1/2"NPT) 3 WHITE (RAL9010) * 175 175°F179°C
571 5.6K PENDENT (1/2"NPT) 9 CHROME PLATED 200 200*F/93*C
590 8.0K UPRIGHT (314"NPT) 7 LEAD COATED 286 286°F/141°C
591 8.0K PENDENT (3/4NPT) 6 WAX COATED 360 1 360°F1182°C
2860F/141*C MAX.
560 8.0K UPRIGHT (1/2°NPT)
8 WAX OVER LEAD 561 8.0K PENDENT (1/2NPT) 286°F1141°C MAX.
TABLE C
PART NUMBER SELECTION
SERIES TY-B PENDENTAND UPRIGHT SPRINKLERS
Limited
Warranty
Products manufactured by Tyco Fire &
Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years
from date of shipment by TFBP. No
warranty is given for products or corn-
pónents manufactured by companies
not affiliated by ownership with TFBP
or for products and components which
have been subject to misuse, improper
installation, corrosion, or which have
not been installed, maintained, modi-
fied or repaired in accordance with ap-
plicable Standards of the National Fire
Protection Association, and/or the
standards of any other Authorities
Having Jurisdiction. Materials found
by TFBP to be defective shall be either
repaired or replaced, at TFBP's sole
option. TFBP neither assumes, nor
authorizes any person to assume for it,
any-other-obligation-in-connection-with--
the sale of products or parts of prod-
ucts. TFBP shall not be responsible for
sprinkler system design errors or inac-
curate or incomplete information sup-
plied by Buyer or Buyer's repre-
sentatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
F.T(T.T1iiT0 maT. WFIT41 [FrouiTiTgili1flj1
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity, in
whole or part, of any portion of this
warranty will not affect the remainder.
Ordering
Procedure
When placing an order, indicate the
full product name. Refer to the Price
List for complete listing of Part Num-
bers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (Specify Model/SIN), Stand-
ard Response, (specify K-factor),
(specify temperature rating), Series
TY-B (specify Pendent or Upright)
Sprinkler with (specify type of finish or
coating), P/N (specify from Table C).
Recessed Escutcheon:
Specify: Style (specify 10 or 40 ) Re-
cessed Escutcheon with (specify*) fin-
ish, P/N (specify*).
* Refer to Technical Data Sheet TFP770.
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001..