Loading...
HomeMy WebLinkAbout3257 CAMINO DE LOS COCHES; 306; AS070036; Permit10/29/2020 AS070036 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS070036 3257 CAMINO DE LOS 30(0 Job Address: Status: ISSUED COCHES Permit Type: SPRINK Applied 2/14/2007 Parcel No: 2550313200 Approved: 2/15/2007 Lot #: 0 Reference No.: Issued: 2/15/2007 PC #: Inspector: Project Title: DR. FRUIN T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O BOX 713194 SANTEE, CA 619-562-6247 Owner: LOSCOCHES VILLAGE LLC C/O CRAIG W CLARK 4180 LA JOLLA VILLAGE DR #405 LA JOLLA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 1/1 OOO tqC01Fire & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 I Series RFII 5,6 K-factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, "Royal Flush Il" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprin- klers must be cut. The Series RFII Sprinklers are shipped with a Disposable Protective IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) 'Royal Flush II" Concealed Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. WARNINGS The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers 1Y3551 (5mm bulb) & 1V3531 (3 mm bulb): maximum 175 psi (12,1 bar) by UL, C-UL, FM, LPCB and NYC. TY3504 (5 mm bulb) & TV3505 (3 mm bulb): maximum 250 psi (17,3 bar) by JULY, 2004 ----;:: . . . - . UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM. Technical Data Approvals for Series RFII UL and C-UL Listed. FM Approved. NYC under MEA 353-01-E. LPCB (Ref. No. 094a/09 for 1Y3551 & 094a/10 for TY3531) Approved. The approvals apply only to the serv- ice conditions indicated in the Design Criteria section and maximum pres- sure ratings indicated in the Model/Sprinkler Identification Num- bers section. Approvals for Air & Dust Seal (Part #10908100) UL and C-UL Listed for use with the RFII (TY3551 & TY3504) Standard Re- sponse Concealed Sprinkler. Temperature Ratings 155F/68C Sprinkler - 135F/57C Plate 200F/93C Sprinkler - 165F174C Plate Discharge Coefient K = 5.6 GPM/psi" (80,6 LPM/bar112) Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) TFPI8I Page 2 of 4 TFPI8I 1/2'NPT SEALING ASSEMBLY FRAME _______ CAP SUPPORT - CUP WITH BULB ROLL FORMED - THREADS - COMPRESSION - CREW S GUIDE PINS (2) DEFLECTOR (DROPPED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO H TAINER SUPPORICUP 0 THREAD UNTIL MOUNTING 0 MPLES SURFACE IS FLUSH WITH LEJECTION CEILING RING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER ASSEMBLY Physical Characteristics Frame .............Bronze Support Cup . Chrome Plated Steel Guide Pins ......Stainless Steel Deflector ...........Bronze Compression Screw ......Brass Bulb ...............Glass Cap ........Bronze or Copper Sealing Assembly .......... Beryllium Nickel w/Teflon* Cover Plate ...........Brass Retainer ............Brass Ejection Spring . . . . Stainless Steel Patents U.S.A. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551 & TY3504), 5 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C-UL Listed as stand- ard response - standard spray sprin- klers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (1Y3531 & TY3505) 3 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Ap- proved as standard response - stand- ard spray sprinklers for use in accord- ance with the current FM Loss Prevention Data Sheets. The Series RFII Concealed Pendent Sprinklers are only listed and ap- proved with the Series RFII Concealed Cover Plates having a metallic or white painted finish. The Series RFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. Installation The Series RFII must be installed in accordance with the following instruc- tions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/680C and 3/32 inch (2,4 mm) for the 200°F/930C tem- perature ratings. A leak tight 1/2 inch NPTsprink!er joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the Center point of the Protec- tive Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". * Registered Trademark of DuPont TFPIBI Page 3 of 4 H 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4" (82,6 mm) C: 2-3/8" to 2-518" (60,3 to 66,7 mm) 3/16" (4,8 mm) D: 1-3/4" to 2-1/4"(44,5 to 57,2 mm) FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C j SPRINKLER SUPPORT CUP ASSEMBLY 1/2" (12,7 mm) THREADED D ADJUSTMENT - FACE OF CEILING, RETAINING RING I MOUNTING _ ___ SURFACE 771 FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORT CUP [ -L 0 .j- LI— 7/8" (23 mm) SQUARE ALIGN ARROWS WITH FRAME ARMS ACCEPTS /11 1/2" SOCKET - DRIVE FIGURE 3 RFII SPRINKLER WRENCH Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- tainer. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The Series RFII must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. Page 4 of 4 TFPIBI SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL / BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY CLEAN ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551 it TY3504) When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTiES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: (SIN), (specify temperature rating) Series RFII Concealed Pen- dent Sprinkler, P/N (specify). 155F/680 200F/93C TY3551 51-790-1-155 51-790-1-200 TY3504 51-796-1-155 51-796-1-200 TY3531 51-792-1-155 51-792-1-200 TY3505 51-797-1-155 51-797-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). 135F/57C(a) 165F/74C*(b) Brass 56-792-1-135 56-792-17165 Bright Brass 56-792-2-135 56-792-2-165 Chrome 56-792-9-135 56-792-9-165 Brushed Chrome 56-792-6-135 56-792-8-165 White 56-792-0-135 56-792-0-165 White (RAL9010)* 56-792-3-135 56-792-3-165 Bright White 56-792-4-135 56-792-4-165 Ott White 56-792-5-135 56-792-5-165 Black 56-792-6-135 56-792-6-165 Custom 56-792-x-135 56-792-X-165 For use with 155F/68C sprinklers. For use with 200F/93C sprinklers. * Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 'S tqC0 Flre & Building I)Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB - 28,429 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2NPT TY1231 - Pendent 2.8K, 1/2'NPT TY2131 - Upright 4.2K, 1/2'NPT TY2231 - Pendent 4.21K, 1/2NPT TY3131 - Upright 5.6K, 1/2 NPT TV3231 - Pendent 5.61K, 1/2'NPT 1Y4131 - Upright 8.0K, 3/4'NPT TY4231 - Pendent 8.0K, 3/4"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/p5i112 (40,3 LPM/barl/2) K = 4.2 GPM/psi112 (60,5 LPM/barl'2) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi1/2 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Page 1 of 8 JULY, 2004 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 7/16" (11,1 mm) 1/2" ** NOMINAL MAKE-IN NPT -r- 2-1/4" (57,2 mm) - TFPI7I Page 2 of 8 STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR (11,1 mm) FFLATS NOMINAL 7/16" MAKE-IN2-3/16" CH (55,6 mm) 1/2 NPT ** SSP DEFLECTOR * H - 2-7/8 (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2 ** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR 2-3/16" 7/16" 1,1 mm) NOMINAL (55,6 mm) (38,11 mm) H ..: ;[6 MAKE WREN( 1-1/2 I 2-3 WRENCH (55,6 mm) FLATS SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. I 1/2 NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Recessed Escutcheon: White Coated, Deflector .......Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) .......Bronze Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. TFPI7I Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) 7/16" (11,1 mm) 1/2" ** NOMINAL MOT MAKE-IN SSP DEFLECTOR* STYLE 10or20 RECESSED ESCUTCHEON SSU DEFLECTOR 6* 7/16 1 5 (11,1mm) NOMINAL MAKE-IN ); 2-3/16' -' (55,6 mm) 1/2' NPT** I 2-7/8 (73,0 mm) DIA. —I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU* 1/2" * NPT DEFLECTOR 2-5/16" (12,7 mm) NOMINAL (58,7 mm) 1-9/16" MAKE-IN 2 1 (39,7 mm) WRENCH (57,2 mm) 3 FLATS SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. 3/4" NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Seating 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE - QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (TV4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler Page 4 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME I WHITE*** LIQUID BRASS PLATED frOLYESTER 135°F/57°C Orange PENDENT (TY1231) and 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/930C Green 2.8 (TY1131) 286°F/141"C Blue 1/2" NPT 135°F/57°C Orange RECESSED PENDENT 155°F/68"C Red 175°F/79°C Yellow (TY1231)* Figure 5 1,2, 5 200°F193°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY1231)** Figure 6 200°F/930C Green 135°F/57°C Orange PENDENT (TY2231) 1551F1681C Red 175°F/79°C Yellow and UPRIGHT 200°F/93°C Green 4.2 1/2" (TY2131) 1,2 286°F/141°C Blue 135°F157"C Orange NPT RECESSED PENDENT 155°F/68°C Red 175°F/79°C Yellow (TY2231)* Figure 7 200°F/93"C Green 135°F/57°C Orange RECESSED PENDENT 1551F/680C Red 175°F/79°C Yellow (TY2231)** Figure 8 200°F/93°c Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED IPOLYESTER WHITE*** LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 1 35°F/57"C Orange 1,2, 3,4,5, 6,7 1,2,3,5 155°F/68°C Red 175°F/79"C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (rf3231)" Figure 9 135°F/57°C Orange 1, 2, 4, 5 N/A 155°F/68"C Red 175°F179°C Yellow 200°F/93°C Green RECESSED PENDENT (rv3231)** Figure 10 135°F/57°C Orange 1, 2, 3, 4, 5 1, 2, 4, 5 N/A 155°F/68"C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 3/4,, PENDENT (TV4231) and UPRIGHT (TY4131) 135°F/57"C Orange 11 2, 3,4,5, 6,7 1,2,5 155°F/68"C Red 175°F/79°C Yellow 200°F/93"C Green 286'F/1 41'C Blue NPT RECESSED PENDENT (TY4231) Figure 11 135"F/57"C Green 1,2,4,5 N/A 155"F/68"C Orange 175"F/79°C Red 200°F/93°C Yellow RECESSED PENDENT (TY4231)** Figure 12 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 2-7/8 DIA. 5/8±1/4' (73,0 mm) 3/4" (19,1 mm) FACE OF *(3,'2 ATE I SPRINKLER 57,2 mm) MONTING (15,9±6,4 mm) .,_2-1/4" DIA. 1/4' (6,4 mm) I mm) FITTING /8" III \% MOUNTING I SURFACE , //" CLOSURE SERIES 1-5/16' (33,3 mm) TY-FRB 13/16' (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. - 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) _____________ (15,9±6,4 mm) - 2-1/4' DIA. I 1/4' (6,4 mm) FACE OF MOUNTING SPRINKLER , PLATE FITTING 57 2mm) 1/8" (32 mm)I MOUNTING /. SURFACE/ SERIES 1-1/4"(31,8 mm) CLOSURE TYFRB 3/4"(19,11 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWOPIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8' DIA. (73,0 mm) 1/2' (12,7 mm) 2-1/4' DIA. 1l /4"(6,4 mm) (57,2 mm) Tj MOUNTING ; rL,Ml I - 1/8" (3,2 mm) I f t 1-5/16' (33,3 mm) 1-1/16' (27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. -' (73,0 mm) 1/2±1/8" 1/2"(12,7mm) r (12,7±3,2 mm) 2-1/4' DIA. I 1/4(6,4mm) I FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE FITTING 1 1/8" (32mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING I \ - MOUNTING SURFACE CLOSURE SERIES TY-FRB Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I - 2-7/8' DIA. - 5/8±1/4" (73,0 mm) I 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF I MM) MOUNTING PLATE SPRINKLER L_S7,2 FITTING 1/8' 7 MOUNTING SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE FY-FRB 3/4' (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 5/8±1/4' (73,0 mm) 3/4'(19,1 mm) (15,9±6,4mm) 2-1/4" DIA. 1/4'(6,4 mm) I FACE OF (57,2 mm) MOUNTING PLATE SPRINKLER FITTING _______ _ _____________ (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13/16"(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 2-7/8' DIA. (73,0 mm) 1/2' (12,7 mm) 2-1/4' DIA. (57,2 mm) 1/4' (6,4 mm)l MOUNTING I - DI I 1/8" (3,2 mm) I 1-1/4' (31,8 mm) 1' (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2±1/8' (73,0 mm) 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4mm) (57,2 mm) f~ I I FACE OF MOUNTING SPRINKLER PLATE FITTING (3 2 mm MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 1/2±1/8' (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES tion and the long term integrity of the Corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI7I P/N 57-XXX---X-XXX I L MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) 1Y1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) 1Y2231 370 5.6K UPRIGHT (1/2"NPT) 1Y3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4NPT) 1Y4131 391 8.0K PENDENT (3/4'NPT) 1Y4231 I I I SPRINKLER 11 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED I 135 155 175 200 286 RATING TEMPERATUR 155°F/68°C 175°F/79°C 200°F/93°C 286°F/141°C * Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR I Ordering Procedure ®tt*ur hbcal distributor for avail- ab1y.indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2 (15 mm) Style 10 Chrome Plated ............P/N 56-701-9-010 White Coated .............P/N 56-701-4-010 White RAL9010*P/N 56-701.3.010 Brass Plated ..............P/N 56-701-2-010 1/2 (15 mm) Style 20 Chrome Plated ............P/N 56-705-9-010 White Coated .............P/N 56-705.4.010 White RAL9010*P/N 56-705-3-010 Brass Plated ..............P/N 56-705-2.010 3/4' (20 mm) Style 30 Chrome Plated ............P/N 56-705-9-011 White Coated .............P/N 56-705-4-011 White RAL9010*P/N 56-705-3-011 Brass Plated ..............P/N 56-705-2-011 3/4 (20 mm) Style 40 Chrome Plated ............P/N 56-700-9-010 White Coated .............P/N 56-700-4-010 White RAL9010*P/N 56-700-3-010 Brass Plated ..............P/N 56-700-2-010 Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446