Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; 204; AS100120; Permit10/21/2020 ASI00I20 Permit Data City of Carlsbad Sprinkler Permit 1905 CALLE *Z.o4 Job Address: BARCELONA Permit Type: SPRINK Parcel No: 2550120400 Lot #: 0 Permit No: ASI00I20 Status: ISSUED Applied 9/22/2010 Approved: 9/22/2010 Reference No.: Issued: 9/22/2010 PC #: Inspector: Project Title: QUATTRA VIA SPA T.I. FIRE SPRINLER PLAN CHECK & INSPECTIONS Applicant: AAA A & D FIRE SPRINKLERS, INC. 2ND FLOOR 11465 WOODSIDE AVE SANTEE, CA 92071 619-448-1962 FOURTH QUARTER PROPERTIES XXX L L C C/O THOMAS TROPEA 45 ANSLEY DR NEWNAN GA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 QUA TTRA VIA SPA 1905 CALLE BARCELONA SUITE 240 SAN DIEGO, CA, CALIFORNIA FIRE SPRINKLER SUBMITTALS MANUFACTURER DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. S 0 SJtaUIiC® AUTOMATIC SPRIKiS_- FIRE V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Mode! V27 standard ' ( spray sprinklers are designed to produce a hemispherical spray pat- tern for standard commer- v2707 cial applications. They are V2708 available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- rates state-of-the-art, heat See pua °tion O1 responsive, frangible glass V2707 bulb design (standard or V2708 quick response) for prompt W . \, precise operation. Pendent V2703 V2701 Upright The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to 3/4" (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts arid water is discharged towards the deflector. The defector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½" (13 mm) K-Factor: 5.6 Imp. (8,1 SI!') Nominal Thread Size: ½" NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) FM Global 250 psi (1725 kPa) UL Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS CS 1000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: 13 Standard: 5,0 mm 13 Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon" tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: 13 Open End: V27 13 Recessed: V38, V38-3 13 Socket: V27 Finishes: 13 Plain brass 13 Chrome plated 13 White painted** 13 Custom paintedna 1] Lead" LI Proprietary nickel Teflon" coating** 155, 200, 286 Standard Response Only: LI Wax"' LI Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. Teflon is a registered trademark of Dupont co. "UL Listed for corrosion resistance in all configurations. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-142-5842) Phone: 905-884-1444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 86-21-58855151 Fax: 610-250-8811 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fan: 86-21-58851298 e-mail:pickvic@victaulic.corn e-mail: viccanada@victaulic.com e-mail: viceuro@vtctaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com 2544 Rev.E 11104 ® Registered Trademark of Victaulic . © copyright 2004 Victaulic SKU 4WcAs-66ULTJ Printed in U.S.A. 11 L.. APPROVALS/LISTINGS Nominal Approved Temperature Ratings °FI'c f Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.l.° Response Type UL FM ULC NYC/MEAt CSFM § V2703 1/2 5.6 Standard Upright ]35-360 135-360 135-360 135-360 135-360 13 8,1 57 182 57-182 57-182 57- 182 57-182 V270] 1/2 5.6 Standard Pendent 135-360 135-360 135-360 135-360 135-360 13 8,1 57-182 57 182 '182 57- 57-182 57 182 V2707 112 5.6 Standard Recessed Pendent 135-286 135-200 135-286 135-286 135-286 13 8,1 Up to YV Adjustment 57- 141 57-93 57- 141 1 57-141 57-141 V2704 ½ 5.6 Quick upright 135-286 135-286 135-286 135-286 135-286 13 8,1 57-141 57-141 57-141 57-141 57 141 V2708 ½ 5.6 Quick Pendent 135-286 135-286 135-286 135-286 135-286 13 8,1 57- 141 57-141 57-141 57- 141 57-141 V2708 1/2 5.6 Quick Recess edPendent 135-200 135-200 135-200 135-200 135-200 13 8,1 Up to 1/2' Adjustment 57 -93 57-93 57-93 57-93 57-93 V2708 ½ 5.6 Quick Recessed Pendent 135-200 No 135-200 135-200 135-200 13 8.1 Up to Y4' Adjustment 5793 5793 5793 Listings and approval as of printing. 0 All are approved open, except for areas designated "No". For K-Factor when pressure is measured in Bar, multiply S.I. units by 10, I MEA #62-99-E. § CSFM #7690-0531:112 .1 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table, S Temperature - oFft Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 68 100 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 150 93 65 Green High 286 141 225 107 Blue Extra High . K 360 300 182 149 Purple - M Open No Bulb .1 Standard response only. All are approved open, except for areas designated "No". - 150/65 if max coated. ORDERING INFORMATION Please specify the following when ordering: J Sprinkler Model Number LJ K-Factor ZI Sprinkler Finish 1] Style Li Thread Size Ci Escutcheon Finish Ci Temperature Rating Ci Quantity Ci Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the I current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10-2 . DIMENSIONS 11/16, (37 mm) 2% (60 mm) 1W (41 mm) 1W i (41 mm) 23h I gJ (60 mm) I (25 mm) V Standard Pendent- V2707, V2708 Standard Upright - V2703, V2704 W (60 mm) Max. Hole min. Hole Typical Ceiling Tile I- Finished Surface (30 mm) MAXIMUM RECESS S (75 mm) MAXIMUM EXTENSION 'A Adjustment Recessed - V2707, V2708 (Drawing not to scale) 2% (60 mm) Max. Hole 2(51 mm) Min. Hole (24 mm)Typical Ceiling Tilef 111/16, Finished Surface (24 mm) MAXIMUM RECESS 2s (75 mm) MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright 40.10 -3 to ----'s ---_- -------- - - to In - - to 10' 3,0 in 8 2,4 6 1,8 4 1,2 2 0,6 C 7 psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa . DISTRIBUTION PATTERNS MODELS V2107, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT 10' 3,0 m 8' 2,4 m 6' 1,8 m 4, 1,2 m 2' 0,6 m 0 7psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa 2' 4' 6' 8' 10' 12' 14 0,6 m 1,2 m 1,8 in 2,4 m 3,0 m 3,7 m 4,3 at MODELS V2703, V2104 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 2 4' 6' 8' 10' 12 14' 16 0,6 in 1,2 m 1,8 m 2,4 m 3,0 in 3,7 tnt 4,3 tnt 4,9 m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not he used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. ..........- _________ WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4 all + i}UJI 3 •. • • tT iq:I i till ! ['IL6m !' Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. EI Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tLICO/F/ow Control c;: allied TUBE & CONDUIT S Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule- 10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (114T_ 8") pipe and Sch-40 (1"- 24") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. WI. Wt. (1120 Filled) Pcs/ WI/lift (21) WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft, Kg/rn Lift Lbs; Kg Lbs, Kg Lbs, Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5,37 44 1,140 1,303 1,357 2 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 763 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 '50 Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2' 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: @ <~> 9 Listed Approved Listed 16100 S. Lathrop' Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 -3 Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring S Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger: Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2' thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions -Weights Pipe Rod Size I Max. Rec. Approx. Size - Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25A 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25A 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/s 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 5/8 41/a 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 73/a 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 is 6 1/2 12mm 101/a 63/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwfolco.com