10/27/2020 AS080036 Permit Data
City of Carlsbad
Sprinkler Permit
1911 CALLE
Job Address:
BARCELONA
Permit Type: SPRINK
Parcel No: 2550120400
Lot #: 0
Permit No: AS080036
Status: ISSUED
Applied 3/20/2008
Approved: 3/20/2008
Reference No.: Issued: 3/20/2008
PC #: Inspector:
Project Title: FREE PEOPLE, SUITE 152 T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTION
Fees ($) Add'I Fees ($) Total ($) Balance
130 0 .130 0
1/1
FIRE PROTECTION INC.
FREE PEOPLE
1911 CALLE BARCELONA STE152
CARLSBAD, CA
FIRE PROTECTION SUBMITTALS
MANUFACTURE'S DATA SHEETS
** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the
construction schedule and shall be deemed accepted by the Purchaser.
I. APPROV 'TSUB1TTED
CARLSBAD FUPARTMENT
many angles. reducing
assembly effort. This sprin-
kler is available in various
temperature ratings (see
chart on page 2) and fin-
ishes to meet many design
requirements.
The recessed pendent
should be utilized with a
Model V27 recessed
escutcheon which pro-
vides up to ,3/4' (19 mm) of
adjustments.
Sprinkler Operation
The operating mechanism
is a frangible glass bulb
which contains a heat
responsive liquid. During a
fire, the ambient tempera-
tore rises causing the liquid
in the bulb to expand.
When the ambient temper
ature reaches the rated
temperature of the sprin-
kler, the bulb shatters. As a
result, the waterway is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to dis-
tribute the water in a pat-
tern that is most effective
in controlling the fire.
Coverage
For coverage area and
sprinkler placement. refer
to NFPA 13 standards.
A lii.r3 - ''
- •- • a TijSij ,I.
V27, K5.6
Models V2703, V2704, V2707 and V2708
Standard Spray
Upright, Pendent and Recessed Pendent
Standard and Quick Response
=
PRODUCT DESCRIPTION
. These Model V27 standard
spray sprinklers are
designed to produce a
hemispherical spray pat-
tern for standard commer-
V2707
I t4 V2708
cial applications. They are
available with either stan-
Recessed dard or quick response
-; '- Pendent bulbs. The design incorpo-
rates state-of-the-art, heat
SeeVictaulic
publication 10.01 responsive, frangible glass
V2707 bulb design (standard or
V2708 , ' quick response,) for prompt,
precise operation.
The die cast frame is more
streamlined and attractive
Pendent V2703 ' than traditional sand cast
V2704 frames. It is cast with a
) hex-shaped wrench boss to
allow easy tightening from Upright
TECHNICAL SPECIFICATIONS
Models: V2703. V2704, V2707
\.2708
Style: Pendent, Upright or
Recessed Pendent
Nominal Orifice Size:
1/2' (13 mm)
K-Factor: 5.6 Imp. (8,1 S.V)
Nominal Thread Size:
1/2'NPT(l5mm)
Max. Working Pressure:
175 psi (1200 kPa) FM Global
250 psi (1725 kPa) UL
Factory Hydrostatic Test:
100% @ 500 psi (3450 kPa)
Mm. Operating Pressure:
7 psi (48 kPa)
Temperature Rating: See
chart on page 2.
MATERIAL
SPECIFICATIONS
Upright Deflector:
Bronze per UNS C22000
Pendent Deflector:
Bronze per UNS C51000
Bulb: Glass with glycerin solo-
non.
Bulb Nominal Diameter:
U Standard: 5,0 rem
U Quick Response: 3.0 into
Load Screw: Bronze per FibS
C65100
Pip Cap: Bronze per UNS
C65100
Spring: Beryllium nickel
Seal: Teflon* tape
Frame: Die cast brass 6530
Lodgement Spring:
Stainless steel per UNS S30200
ACCESSORIES
Installation Wrench:
U Open End: V27
U Recessed: V38, V38-3
U Socket: V27
Finishes:
U Plain brass
Ii Chrome plated
U White painted*
U Custom painted
U Lead
U Proprietary nickel Teflon*
coating**
155, 200, 286 Standard
Response Only:
U Wax *
U Wax over lead**
For cabinets and other accesso-
ries refer to separate street.
NOTE: Weather resistant recessed
esdLilcheolls available upon request.
For KFsctor when pressure is mea-
sured in [3cr. multiply S.I.units by
10.0.
- lotion is a registered trademark of
Dupont co.
'UL Listed for cortosion resistartcc in all
configurations.
VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific
Phone: 1-800-PlCKVIC (1-800.742.5842) Phone: 905 884 7444 Phone: 32-9-381-1500 Phone. 510-5.59-3300 Phone: 86-21-58855151
Fan: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 6105593608 Fax: 86-21-58851298
e-rnail:pickvic@victaxlit.com e-mail: viccanada@victaulic.com e-1112i1: viceuro@victaulic.be e-mail: vital@viclaulic.com e-mail: vicap@victxulic.com
2544 Rev E 11/04 tO Registered Trademar* of Victaul c C Copyright 2004 Victaulic SKU SWcAS-SSULTJ Prated in U.S A.
!i.ii I[t
Nominal Approved Temperature Ratings °FIC 1 1
Orifice Size K-Factor
Inches Imperial Deflector
Model millimeters S.l.° Response Type UL FM ULC NYC/MEAt CSFM §
½ 5.6 135- 360 135- 360 135- 360 135-360 1 35 - 360 V2703 13 81 Standard Upngnt 57-182 57-182 57-182 57-182 57- '182
½ 5.6 135-360 135- 360 135-360 135-36(1 135-300 V270i 13 81
. Standard Pendent 57- 182 57-182 57- 182 57 - 182 57-182
½ 56 Recessed Pendant 135-286 135 -200 135- 286 135- 286 135 -286 V2/0/ 13 8.1 Standard Upto1/4 Adjustment 57-141 1 57-93 57-141 57-111 57-111
V2/04 ½ 56 Quick -. Upright 135-286 135-286 135-286 135-286 135-286
13 8.1 57-141.1 57- 1.11 57- 141 57-111 'ill 57-
½56 135-286 135-286 135-286 135-286 735-286 V/08 13 8,1 Quick Pendent 57 - 141 57-141 57 -141 57-141 57-141
85 5.6 Recessed Pendent 135-200 135-200 135 -200 135-200 135-200 Vs 708 13 8,1 Quick lip to ½ Adjustment 57 - 93 57. 93 57 .93 57 - 93 57 93
1/2 5.6 . Recessed pendent 135 -200 135 - 200 135- 200 135- 200 V2708 13 8,1 Qtiick Upto ~'Aciustmonl 57 -93 57-3 57'3
Listings and approval as 01 printing. 17 All are approved open, exceptt for areas riexipristed No".
For K-Factor when pressure is rrreasurod in Bar, multiply S. I. units by 10
MEA #62-99-E. § CSFM 47690-0531:112
Temperature -
Sprinkler Victaulic Nominal Maximum Glass
Temperature Part Temperature Ambient Temp. Bulb
Classification Identification Rating Allowed Color
Ordinary A '
135
57
100
38 Orange
Ordinary c 155 1 00
68 38 Red
intermediate E 175
79 65
150
.
Yellow
Intermediate F 200
93
750
65 Green
High J 286
1,11,10?
225 Blue
Extra High t K 360
182
300
- PLrrple
- M Open No Bulb
7 Standard response only.
All are approved open, oacopl for areas designated No"
-- 150165 if wax coated
RATINGS
All glass bulbs are rated for
temperatures fiorn -67°F
(-55°C) up to those shown
in adjacent table.
,41
Please specify the following
when ordering: 1,] Sprinkler Model Number U K-Factor U Sprinkler Finish
U Style U Thread Size U Escutcheon Finish
U Ternperat:ure Rating U Quantity U Wrench Model Number
Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation
of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products.
Installation rules, especially those governing obstruction, must be strictly followed.
Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed.
Failure to follow these instructions could result in serious personal injury and/or property damage.
The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the
urrent National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional
maintenance, testing, and inspection requirements that must be followed.
If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton,
Pennsylvania 18044-0031, 610-559-3300.
40.10-2
(60
(25 mm)
Standard Pendent - V2707, V2708
(60
Standard Upright - V2703, V2704
S
==
DIMENSIONS
21'2 (60 mm)
Max. Hole
Min, Hole
:::::::::m 1P1
MAXIMUM RECESS
(75 mm)
MAXIMUM EXTENSION
1/a Adjustment
Recessed - V2707, V2708
(Drawing not to scale)
2% (60 mm)
Max. Hole
2" (51 mm)
Mm. Hole
(33 ing (24"mm) :±c
:::::::T/ii c6:
MAXIMUM RECESS
(75 mm)
MAXIMUM EXTENSION
3/4 Adjustment
Recessed - V2707, V2708
(Drawing not to scale)
AVAILABLE WRENCHES
V27
Socket
V38 or V38-3
Recessed
V27
Open End
V2707, V2708 Pendent / / /
V2707,V27O8 Recessed Pendent / / -
V2703, V2704 Upright - / /
40.10 - 3
DISTRIBUTION PATTERNS
S MODELS V2707, V2708
K5.6 STANDARD PENDENT AND RECESSED PENDENT
DISTRIBUTION PATTERNS - TRAJECTORY
'U
3,0 m
8'
2,4 m
7 psi
48 kPa
6'
1,8 m
15 psi
103 kPa
4-
1,2 m
30 psi -------
207 kPa
2-
0,6 m
(1
0,6 rn 1,2 In 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m
MODELS V2103, V2704
K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY
mi
0,6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m 4,9 m
NOTES:
L Data shown is approximate and can vary due to differences in installation.
These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireL,ocic Automatic Sprinklers. They are
provided as information for guidance in avoiding obstructions to sprinklers and should not he used as rniriiniurn sprinkler spacing jules for installation. Refer to
[I re appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and
Warranties.
All patterns are symmetrical to the centerline of the waterway.
WARRANTY . Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product shall be manufactured by Vic:iauiic company. All Droducis to be irisealit-rd ire ecc;ondanrca with curie-era Victaulic instollslionlassearhly risliuctions.
Victaulic reserves the right to chasge product specifications, designs and standard equipment WitliOLit notice and without incurring obligations.
40.10-4
10'
3,0 m
8
2,4
6
1,8
4
1,2
2
0,6
0
7psi
48 kPa
15 psi
103 kPa
30 psi
207 kPa
\jtaulic®
AUTOMATIC SJ -
; 1
V27, K5.6
Models V2709 and V2710
Standard Spray
Horizontal Sidewall and
Recessed Horizontal Sidewall
Standard and Quick Response
PRODUCT DESCRIPTION
V2709
Standard V2710
Horizontal Sidewall
FM
V2700
V2710
Recessed
Horizontal Sidewall
These Model V27, standard
spray horizontal sidewall
sprinklers are designed for
standard or recessed instal-
lation. The design provides
a crescent-shaped water
discharge pattern for instal-
lation along a wall or under
a beam or ceiling. The
design incorporates state-
of-the-art, heat responsive,
frangible glass bulb design
(standard or quick
response) for prompt, pre-
cise operation.
The die cast frame is more
streamlined and attractive
than traditional sand cast
frames. It is cast with a
hex-shaped wrench boss to
allow easy tightening from
many angles, reducing
assembly effort. This sprin-
kler is available in various
temperature ratings (see
chart on page 2) and
finishes to meet many
design requirements.
The recessed pendent
should be utilized with a
Model V27 recessed
escutcheon which pro-
vides up to 3/4 ' (19 mm) of
adjustments.
Sprinkler Operation
The operating mechanism
is a frangible glass bulb
which contains a heat
responsive liquid. During a
fire, the ambient tempera-
ture rises causing the liquid
in the bulb to expand.
When the ambient temper-
ature reaches the rated
temperature of the sprin-
kler, the bulb shatters. As a
result, the waterway is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to
distribute the water in a
pattern that is most effec-
tive in controlling the fire.
Coverage
For coverage area and
sprinkler placement, refer
to NFPA 13 standards.
S
TECHNICAL SPECIFICATIONS
Models: V2709, V2710
Style: Horizontal Sidewall or
Recessed Horizontal Sidewall
Nominal Orifice Size:
1/2" (13 mm)
K-Factor: 5.6 Imp. (8,1 5.1.")
Nominal Thread Size:
½" NPT (15 mm)
Max. Working Pressure:
175 psi (1200 kPa)
Factory Hydrostatic Test:
100% @ 500 psi (3450 kPa)
Mm, Operating Pressure:
7 psi (48 kPa)
Temperature Rating: See
chart on page 2.
MATERIAL
SPECIFICATIONS
Horizontal Deflector:
UNS C22000 Commercial bronze
Bulb: Class with glycerin solu-
tion.
Bulb Nominal Diameter:
Li Standard: 5,0 mm
Li Quick Response: 3,0 mm
Load Screw: UNS C65 100 Low
Silicon bronze
Pip Cap: UNS C65 100 Low Sili-
con bronze
Seal: Teflon* tape
Spring: Beryllium nickel
Frame: Die cast brass 65-30
Lodgement Spring:
UNS S30200 Stainless steel
ACCESSORIES
Installation Wrench:
Li Open End: V27
Li Recessed: V38-3
Finishes:
0 Plain brass
Li Chrome plated
Li White painted**
Li Flat black painted**
Li Custom painted**
Li Lead**
155, 200, 286SR Only:
Cl Wax**
Li Wax over lead**
For cabinets and other accesso-
ries refer to separate sheet.
For K-Factor when pressure is mea-
sured in Bar, multiply S.I. units by
10.0.
Teflon is a registered trademark of
Dupont cc.
UL Listed for corrosion resistance in
all configurations. (Exaggerated for clarity)
VICTAULICa IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of America Victaul',c. Company of Canada VictnuUc Europe Victaulic America ...alma Victaulic Asia Pacific
Phone: 1-800-PIcK-VIC (1.800-742-5842) Phone: 416-675-5575 Phone:329-381.1500 Phone: 610-559-3300 Phone: 65-6235-3035
Fax: 610-250-8817 Fax: 416-675-5565 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535
e-mail:pickvit@victaulic.com e-mail: xitcanailaOvittouli:.t:om e-mail: viceuro@victaulic.be e-mail: vital@victaulic.com e-mail: vicap@victaulit.com
2545 Rev.D 11102 5 Registered Trademark of Viclaulic St copyright 2002 Victaubc Printed in U.S.A.
fl
APPROVALS/LISTINGS
Nominal Approved Temperature Ratings °FI; 1: il
K-Factor
Orifice Size Imperial Deflector
Model lncheshr.r. Ui: Response Type UL FM@ ULC NYC/MEAt CSFM §
V2709 1/2
:.
5.6 Standard Horizontal Sidewall
135-360 135-360 135-360 135-360 135-360
V2709 1/2 56 Standard Recessed HSW 135-200 135-200 135-200 135-200 135-200
Up to 1/4" Adjustment - .
V2710 1/2 5.6 Quick 135-286 Horizontal Sidewall 135 - 286 135-286 135-286 135-286
V2710 1/2 5.6 Quick Recessed HSW 135-200 135-200 135-200 135-200 135-200
Upto lb" Adjustment
V2710
1/2 5. 6 . Quick RecessedHSW
Up to
135-200 No 135-200 135-200 135-200
: 1/4"Adjustment .: .
I Listings an approval as of printing. 0 All are approved open, except for areas designated "No". @ Light Hazard only.
For K-Factor when pressure is measured in Bar, multiply SI. units by 10.0.
MEA #62.99-E. § CSFM #7690-0531:112
RATINGS
All glass bulbs are rated for
temperatures from -67°F
(-55°C) to those shown in
adjacent table,
Temperature - °FI"C
Sprinkler Victaulic Nominal Maximum Glass
Temperature Part Temperature Ambient Temp. Bulb
Classification Identification Rating Allowed Color
Ordinary A 135 100 Orange
Ordinary c 15 1-
00
Red
Intermediate E 175
.
150
, Yellow
Intermediate 1 200 150
c,'. Green
High J 286 225— Blue
Extra High t K 360 300 Mauve
- M Open T No Bulb
Standard response only.
All are approved open, except for areas designated "No".
- 150/65 if wax coated.
ORDERING INFORMATION
Please specify the following
when ordering: U Sprinkler Model Number
U Style
U Temperature Rating
U K-Factor U Sprinkler Finish
U Thread Size U Escutcheon Finish
U Quantity Cl Wrench Model Number
Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation
of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products.
Installation rules, especially those governing obstruction, must be strictly followed,
tot . • Painting, plating, or any re-coaling of sprinklers (other than that supplied by Victaulic) is not allowed.
Failure to follow these instructions could result in serious personal injury and/or property damage.
The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the
current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional
biaintenance, testing, and inspection requirements that must be followed.
If you need additional copies of this publication, or if you have any questions about the sale installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton,
Pennsylvania 18044-0031, 610-559-3300.
40.11-2
DIMENSIONS
3" (89 mm) . 21/4' (57 mm) -
(32 mm) •. -
(8 rn L mm)
Standard HSW - V2709, V2710
2~
(56 mm)
4-12"(102 - 305 mm)
Per NFPA
J
(17 mm)
AS" (14 mm) -11%" lYe"
(43 mm) 127 mm)
Finished Ceiling Finished Ceiling
4-12(102-305mm)
Per NFPA
2" (51 mm) 2%" (60 mm)
Min. Hole Max. Hole
Finished Surface -" -4 I- Typical Wall
MAXIMUM EXTENSION
I11 2" (51 mm) 21A" (60 mm)
(75 mm) - I Mix. Hole Max. Hole
I -
Finished Surface
Typical Wall
MAXIMUM RECESS
0
1/2" Adjustment
Recessed — V2709, V2710
(DrawI7g not to scale)
j(24rnrn)
21%" 9%" (14 mm) )- 1',is" -4-..- iSis" -' - - -
(56 mm) ' I ) (37 mm) I (33 mm)
I I \_ Finished Ceiling I z . . "— Finished Ceiling
4-12)102-305mm) I 4-12 (102-305mm)
Per NFPA ---I---------------------- Per NFPA -'
_- . .1 _=l
2" (51 mm) 23/h" (60 mm)
Mm. Hole Max. Hole
Finished Surface -'
—4 )— Typical Wall
MAXIMUM EXTENSION
2 5As" 11 2" (51 mm) 2~" (60 mm)
(75 mm) Mm. Hole MaxHole
Finished Surface t L_ Typical Wall
MAXIMUM RECESS
3/4" Adjustment
Recessed — V2709, V2710
(Drawog not to scale)
,,,-............
AVAILABLE WRENCHES
V38-3
Recessed
V27
Open End
No escutcheon / /
With escutcheon / -
40.11-3
DISTRIBUTION PATTERNS
[IJ MODELS V2109, V2710
K5.6 STANDARD HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL
DISTRIBUTION PATTERNS - TRAJECTORY
10' fl -
3,0 ti
8'
2,4 in
6'
1,8 rn
1,2 m
0,6 in
0
1 -
-
2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26'
0,6 in 1,2 m 1,8 m 2,4 in 3,0w 33 in 43 m 4,9 in 5,501 61 in 6,7 m 7.3 m 7,9 in
7ps1
48 kPa
15 psi
103 kPa
30 psi
207 kPa
MODELS V2109, V2710
K5.6 STANDARD HORIZONTAL SIDEWALL
DISTRIBUTION PATTERNS - PLAN VIEW
2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28'
0,6 in 1,2 in 1,8 in 2.4 in 3,0 in 3,7 m 4,3011 4,9 in 5,5 in 6,1 in 63 in 73 in 7,9 in 8,5rn
0,6 in
4,
1,2 in
6'
1,8 in
8'
2,4 ti
10'
3,0 in
12'
3,7 in
14'
4,3 in
16'
4,9 m
7psi
48 kPa
15 psi
103 kPa
30 psi
207 kPa
NOTES:
Data shown is approximate and can vary due to differences in installation.
These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are
provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to
the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War-
ranties.
WARRANTY
S
Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product shall be manufactured by Victaulic company. All products to be installed in accordance with current Victaulic installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
40.11 -4
J:); cjffii
Our advanced formula mill coating of-
fers a clean, durable surface. It is also
paint-ready for custom color applications
without special preparation.
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
products up to 4.5000" in diameter is
coated with our new Antibacterial For-
mula, "ABF". In scientific laboratory
test, ABS proved to have superior resis-
tance to microbial colonization of pipe
walls, thereby delaying or possibly pre-
venting the onset of Microbiologically
Influenced corrosion (MIC) when the
First Sprinkler System is first installed.
•
Welded Outlets
Hydrostatic Pressure
Side Wall Rupture
Vibration Test
tLICO/FIOw Control
S
itIt! I iPIi II [I]
Fully Listed and FM Approved Sprinkler Pipe
When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these
products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand.
Our Sch-10 (1'/4"- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe
products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.
Schedule-10/Schedule-40 product can be
"hot-dip" galvanized to meet FM
requirements for dry systems in
accordance with the zinc coating
specifications of ASTM A-123.
Meets "Buy American" requirement
and is available through distributors in
the USA, Canada and Mexico.
[sSpecifications
NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WtJl.ift (21') WI/Lift (24') WI/Lift (25)
In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1.049 1.680 2.05 70 2,470 2,822 2,940
25 26.6 2.5 3.05 70 1,120 1,280 1,334
1¼' 1.380 2.270 2.93 51 2,431 2,778 2,894
32 35.1 4.36 4.36 51 1,103 1,260 1,313
11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992
40 40.9 4.0 5.37 44 1,140 1,303 1,357
2.067 3.650 5.13 30 2,300 2,628 2,738
50 52.5 5.4 7.63 30 1,043 1,192 1,242
21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750
65 62.7 8.6 11.73 19 1,048 1,197 1,247
Sch-10 Specifications
NPS Nominal I.D. WI. WI. (H20 Filled) Pcsf Wt/LilI (21) WI/Lill (24') Wt/Litt (25')
In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1.097 1.400 1.81 91 2,675 3,053 3,185
25 27.9 2.1 2.70 91 1,213 1,385 1,445
11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760
32 36.6 2.7 3.75 61 1,052 1,208 1,252
11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172
40 42.7 3.1 4.52 61 1,208 1,381 1,439
2.157 2.640 4.22 37 2,051 2,344 2,442
50 54.8 3.9 6.28 37 930 1,063 1,108
21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648
65 66.9 5.3 8.77 30 1,009 1,153 1,201
3.260 4.330 7.94 19 1,728 1,975 2,057
80 82.8 6.4 11.82 19 784 896 933
4' 4.260 5.610 11.78 19 2,238 2,558 2,665
90 108.2 8.3 17.53 19 1,015 1,160 1,209
5.295 7.77 17.33 10 1,632 1,865 1,943
125 134.5 11.56 25.80 10 740 846 881
6.357 9.290 23.03 10 1,951 2,230 2,322
150 161.5 13.8 34.27 10 885 1,012 1,053
8" 8.249 16.490 40.15 7 2,424 2,770 2,885
200 209.5 24.5 59.75 7 1,100 1,256 1,309
Schedule-10/Schedule-40 pipe are in
compliance with the following:
ASTM A-135, and NFPA 13. Both pipe
products have a working pressure rating
of 300 psi maximum and also meet the
stringent requirement for the following
tests:
(@ <~> 9
Q Listed Approved Listed
Qallied 16100 S. Lathrop• Harvey, IL 60426 Customer Service:
r cJIIeI) 11350 Norcom Rd. - Philadelphia, PA 19154 (800) 8825543
TUBE& CONDUIT 2525 N. 27 th Ave. Phoenix, AZ 85009 Fax 708-339-1806
S5 -3