Loading...
HomeMy WebLinkAbout1915 CALLE BARCELONA; 130; AS150072; PermitCity of Carlsbad Sprinkler Permit Permit No: AS150072 1915 CALLE Job Address: Status: ISSUED BARCELONA Permit Type: SPRINK Applied 4/6/2015 Parcel No: 2550120400 Approved: 4/8/2015 Lot #: 0 Reference No.: Issued: 4/8/2015 PC #: Inspector: Project Title: SUR LA TABLE RELOCATE NEW OR CONCEALED SPRINKLERS PER SUR LA TABLE KITCHEN HOOD LAYOUT. Applicant: Owner: US FIRE PROTECTION T-C FORUM AT CARLSBAD L L C 945 SAMAR CT C/O TIAA-CREF CORONA, CA 92880 4675 MACARTHUR CT #1100 NEWPORT BEACH CA 951-316-5665 Fees ($) Add'I Fees ($) Total ($) Balance ($) 70 0 70 0 3 A I" SCHEDULE- 10/40 Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule- 10 /Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule- 10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1h/?_ 8") pipe and Sch-40 (1"- 214I) pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WI/Lift (21) WI/Lilt (24') WI/Lilt (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. WI. WI. (1420 Filled) Pcs/ Wt/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 (9 <~> 9 Listed Approved Listed 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 -3 Galvanized Pipe Schedule- 10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqco/Flow Control c; allied TUBE & CONDUIT SAMMYS® FOR WOOD Not less than 2" nominal width II Not less than 3" nominal thickness (2-1/2") (depth or side of member) Wood Wood Joist Double Sheebock Ceiling No pre-drilling required. "Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. "Made in the U.S.A. 17. Watch a aides demosshstion www.ftwbuildex.com) a. #14 Black Nut Driver Part # 8113910 i . #14 SW Red NO Driver Part 4 8114910 - 1/4" 8002957 GST 100 1/40 1" 25 125 8003957 GST 200 1/4v2' 1760 (Ri) 25 125 1/4" 8004957 GST 300 1/40 3 2060 (Fir) 25 125 3/8" 8007957 GST 10 1/401" 210 (7116- 300 25 125 1 T' 3/8 8008957 GST 20 114x2" 1760 (Fir) 850 1475 25 125 8 8068925 GST 20-SS 1/4n2 1760 - 850 T5 125 3/8"8009925 GST 25-380 3/8x2-112" 2113 (Fir) 1500 25125 E30 80957 GST 3O 1/4x3 2060 (FIr) 1500 1475 25 125] 3/8" 8069925 GST 3O-SS114x3"2060(Fir) 25125 L895 _GST 4O_ 1/4x4 2180 (Fir) 125 -1/2" 8013925 GST 2 - 1/4x2" 1760 (Fir) 25 125 1/2 8014925 GST 2S-380_3/8x21/2" ________ 2113 (FIr) -- 25 125 - 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 0 MADEINUS7 'T ( DoHS SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pie-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. / (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in f- hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cIJI) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4 (20mm) thru 8 (200mm)). Fig. 201 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pie-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Fig. 200_21/2 to 200-8 a Fig. 200 ". 1 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B311ONF) ODTOLCCT Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) C@ us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) WED Fig. 2005 - "Trimline" Adjustable Band Hanger with Non-Captured Nut Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. WtJ100 lbs. (kg) 200-1/2 1/2" (15) /8"-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) ii (5.0) 200-1 1" (25) 3/8"-16 3/e" (85.7) 2/8" (66.1) 12 (5.5) 200-11M 11/4' (32) /t -16 33/4' (94.0) 2/t" (73.0) 13 (5.9) 200-1/2 11/2" (40) 3/8"-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 20 (50) 3/8"-16 41/2° (114.3) 3' (76.3) 15 (6.9) 200-21/2 21/2° (65) /8"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3° (75) /s-16 5/8' (149.1) 4" (101.6) 29 (13.3) 200_31/2 31/2" (90) /-16 7/8" (181.3) 51/4" (133.3) 34 (15.6) 200-4 4' (100) It"-16 73/s' (187.3) 5" (121.0) 35 (16.0) 200-5 50 (125) 1/2..13 91/8" (231.8) 6114" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8" (257.2) 6/4' (171.4) 73 (33.4) 200-8 - 80 (200) 1/2"_13 131/80 (333.4) 8/4" (222.2) 136 (62.3) C Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 B-Line by Er.T.ft Fig. 24 - Hanger for CPVC Plastic Pipe & lPS Steel Pipe** Double Fastener Strap Side Mounted (Cooper B-Line B3183) Size Range: 3/4' (20mm) thru 2" (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" X 1" tek type screws. Meets and exceeds the requirements of NFPA 13,1311 and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws" furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact ) tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. 24-I4 CPVC 3/4" (20) 2/16" (58.7) 1/32" (27.8) 1/16" (30.2) 51/2 (1.67) lr_ Head /16" Hex Size (7.9) 9 j . (4.1) 24-1 1" (25) 2/8" (66.7) 1I16" (33.3) 1/16" (30.2) 6 (1.83) /16" (7.9) 9 (4.1) 24.11/4 11/4" (32) 3" (76.2) 11/2 (38.1) 1/16" (30.2) 61/2 (1.98) /16" (7.9) 11 (5.0) 24_11/2 11/2 (40) 31/4' (82.5) 15/8" (42.3) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 24-2 1 2" 1 (50) 311/16" 1 (93,7) 1127/32' 1 (43.6) 11/16" 1 (30.2) 1 8 1 (2.44) 1 5/16" 1 (7.9) 1 15 1 (6.8) Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4" (20mm) thru 2" (40mm) pipe. Material: - Pre-Galvanized Steel c®us USTED Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4" (20mm) thru 2' (40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. P p—OOøL B-Line co2- Worldwide I www.tyco-fire.com Contacts Series RFII - 56 K-factor "Royal Flush Il" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-F) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/p5i112 (80,6 LPM!bar1/2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPI8I SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT [j WITH THREAD CUP UNTIL 0 0 %_— DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING / SOLDER -' -_ COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY GUIDE PINS (2) DEFLECTOR 1/2 NPT FRAME SUPPOR CUP WIll ROLL FORF THREADS EALING SEMBLY CAP BULB PRESSION CREW FLECTOR POPPED POSITION) TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. LLI1t(.I Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and B: 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2' (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER - DIMENSION C 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32' (2,4 mm) POSITION ASSEMBLY Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. COVER PLATE PROFILE DEPTH DIMENSION B A: 3-1/4 inches (82,6 mm) COVER PLATE DIAMETER DIMENSION A C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) As long as the Protective Cap remains in place, the system is considered "Out of Service" Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFPI8I Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING -"*— SEAL BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass .......... 56-792-1 -135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005) .... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-x-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales Only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tuco TEFLON is trademark of The DuPont Corporation. -