Loading...
HomeMy WebLinkAbout2215 CALLE BARCELONA; ; FA070021; PermitCity of Carlsbad Fire Alarm Permit Job Address: 2215 CALLE BARCELONA Permit Type: FALARM Parcel No: 2552730700 Lot#: 0 Reference No.: PC#: Permit No: FA070021 Status: ISSUED Applied 2/5/2007 Approved: 2/5/2007 Issued: 2/5/2007 Inspector: Project Title: COASTLINE COMMUNITY CHURCH TWO FIRE ALARM INSPECTIONS @ $62/EA Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Fees($) 124 Add'I Fees($) 0 Owner: COASTLINE COMMUNITY CHURCH 511 ENCINITAS BLVD #104 ENCINITAS CA Total($) 124 Balance($) 0 FIRE ALARM -SECURITY LOW VOLT AGE SYSTEMS Coastline Community Church Modular Building -Phase II CARLSBAD FIR Arroyo La Costa Church Site 2215 Calle Barcelona Carlsbad, CA FIRE ALARM SYSTEM fAo:,-002-( c:::::t Coastline Community Church Modular Building -Phase II Arroyo La Costa church Site 2215 Calle Barcelona Carlsbad, CA BILL OF MATERIALS NOTIFIER NFW2-100 FIRE ALARM CONTROL PANEL CSFM# 7165-0028:235 NOTIFIER FDU-80 LIQUID CRISTAL DISPLAY FIRE ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER NOT-BG12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:199 NOTIFIER NP-100 ADDRESSABLE PHOTO ELECTRIC SMOKE DETECTOR CSFM# 7272-0028:231 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULES CSFM# 7300-0028:230 WHEELOCK AS AUDIBLE STROBE APPLIANCES CSFM# 7125-0785:131 WHEELOCK SERIES RSS STROBE APPLIANCES CSFM# 7125-0785:141 FireWarden-100-2(E) Intelligent Addressable FACP with Built-In Communciator GENERAL The Notifier FireWarden-100-2 (NFW2-100) is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This com- pact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 3 for specific installation instructions.) The FireWarden-100-2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. Available accessories include LED, graphic and LCD annunci- ators, and reverse polarity/city box transmitter. The panel is programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. NOTE: Unless otherwise specified, the terms FireWarden-100-2 is used in this document to refer to both the FireWarden-100-2 and the FireWarden-100-2E FACPs (Fire Alarm Control Panels). FEATURES • On-board DACT. • Four Class B or two Class A NAC circuits. • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. • Complies with UL 864 9th Edition requirements. • Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. • Up to 32 annunciators or remote annunciators via EIA- 485. • EIA-232 printer/PC interface (variable baud rate) on main circuit board. • Integral BO-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings control. • Detector sensitivity test capability (NFPA 72 compliant). • History file with 1,000-event capacity. • Maintenance alert warns when smoke detector dust accu- mulation is excessive. • Automatic device type-code verification. • One person audible or silent walk test with walk-test log and printout. • Point trouble identification. • Waterflow (nonsilenceable) selection per monitor point. • System alarm verification selection per detector point. DN-7101 • A1-110 (@NOTI Fl ER® by Honeywell • PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: • SLC can be configured for NFPA Style 4, 6, or 7 operation. • SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). • SLC loop maximum length 10,000 ft. (3,000 m.). See wire table on page 3. NOT/FICA T/ON APPLIANCE CIRCUITS (NAGS): • Four onboard NACs with additional NAC capability using output control modules (NC-100). • Silence Inhibit and Auto Silence timer options. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. • Selectable strobe synchronization per NAC. • 2.5 amps maximum per each NAC circuit. NOTE: Maximum or total 24VDC system power shared between all NAG circuits and auxiliary power outputs is 3.6 amps. (System power increases to 6.6 amps with optional XRM-24 transformer.) PROGRAMMING AND SOFTWARE: • Autoprogram (learn mode) reduces installation time. • Custom English labels (per point) may be manually entered or selected from an internal library file. • Two programmable Form-C relay outputs. • 99 software zones. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. DN-7101 • 06/02/06 -Page 1 of 4 USER INTERFACE LED INDICATORS • AC POWER (green) • FIRE ALARM (red) • SUPERVISORY (yellow) • ALARM SILENCED (yellow) • SYSTEM TROUBLE (yellow) • MAINTENANCE/PRESIGNAL (yellow) • DISABLED (yellow) • BATTERY FAULT (yellow) • GROUND FAULT (yellow) KEYPAD CONTROLS • ACKNOWLEDGE/STEP • ALARM SILENCE • DRILL • SYSTEM RESET (lamp test) • 16-key alpha-numeric pad (similar to telephone keypad) • 4 cursor keys • ENTER ORDERING OPTIONS NFW2-100(E): 19B-point addressable Fire Alarm Control Panel, one SLC loop. Includes BO-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. DP-9692B: Optional dress panel for FireWarden-100-2. TR-CEB: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24(E): Optional transformer. Increases system power to 6.6 amps. Use XRM-24E with FireWarden-100-2E. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. COMPATIBLE ANNUNCIATORS ACM-BR: Relay module provides B Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: BO-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the FireWarden-100-2, see the following data sheets (docu- ment numbers) ACM-BR (DN-3558), ACS/ACM Series (DN-0524), LDM Series (DN-0551 ), FDU-80 (DN-6820). Page 2 of 4 -DN-7101 • 06/02/06 COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. Nl-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detec- tor. NP-100T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. ND-100: Photoelectric low-flow duct smoke detector. ND-100R: Photoelectric low-flow duct smoke detector with relay option. NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.o• (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0' (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMBS00: Used to mount all modules except the NMM-100P. NOTE: For more information on Compatible Addressable Devices for use with the FireWarden-100-2, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100/NP-t00T (DN-6995), Nl-100 (DN-6996), NH-100/NH-t00R (DN-6997), ND- 100/ND-1 00R (DN-7006), NMM-100/NMM-1 00PINDM-1 00INZM- 100 (DN-6999), NC-100/NC-t00R (DN-7000), and NOT-8G12LX (DN-7001). WIRING REQUIREMENTS While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. SLCWire Distance in Feet Wire Size Wire Type Requirements (m) Non-Plenum (FPLR): Twisted-pair, unshielded 10,000 feet (3,048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 16AWG (1.31 mm2) Genesis 4311, Belden 5220UL 4,875 feet (1,486 m) Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL FireWarden-100-2 Wire Requirements DN-7101 • 06/02/06 -Page 3 of 4 SYSTEM SPECIFICATIONS SYSTEM CAPACITY • Intelligent Signalling Line Circuits ....................................... 1 • Addressable device capacity .......................................... 198 • Programmable software zones ......................................... 99 • Annunciators .................................................................... 32 ELECTRICAL SPECIFICATIONS AC Power: FireWarden-100-2: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7 -18 AH. FireWarden-100-2 cabinet holds maxi- mum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) or one Style Z (Class A) for a total of four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (PIN 71252 UL listed) for Style Y (Class B) NAC. Refer to Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.5 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.5 amps for powering four- wire smoke detectors. Power-limited. Refer to Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 voe. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Requires dedicated business tele- phone number with a minimum of 7 volts DC. Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. CABINET SPECIFICATIONS Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.12' (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CEB): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. SHIPPING SPECIFICATIONS Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0-49° C/32-120° F and at a relative humidity 93% ± 2% RH (noncon- densing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27° C/60-80° F. NFPA STANDARDS The FireWarden-100-2 complies with the following NFPA 72 Fire Alarm Systems requirements: -LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). -AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). -REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTMF). -PROPRIETARY (Automatic, Manual and Waterflow). -CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). -AUTO DETECTOR SELF TEST AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic FireWar- den-100-2 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S624 Microsoft® and Windows® are registered trademarks of the Microsoft Corpo- ration. ©2006 by Honeywell lntemational Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. kd=I ;ii iii =f •J ENllNHIINC I MANDIAfflBINC QUlllTY SYSTEMS Page 4 of 4 -DN-7101 • 06/02/06 We try to keep our prodLJct information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIF ORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-0028:235 Control Unit (Non High-Rise) Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 Page 1 of 1 Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/ReseVRestart period shall not exceed 30 seconds. 7165-0075:208 *Rev/Recert 06-27-2006 jew This listing is based upon technical datc1 submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 27, 2006 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 @) NOTI Fl ER® GENERAL The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER AFP-300, AFP- 400, AFC-600, and.NFS-640 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and dis- plays complete system point status information. Up to 32 FDU- 80s may be connected onto the EIA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. NOTES: 1) The FDU-80 Is compatible with the NOTIFIER AFP-300/ 400 Rev. 3.62 or higher, AFC-600 (all revisions), and NFS- 640 Rev. 2.01 or higher. 2) The FDU-80 can be used on the same data loop as the LCD-80/LCD-B0TM annunciators revision 1.6 software or higher. FEATURES • BO-character Liquid Crystal Display. Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. • No programming necessary -FDU-80 connects to the terminal mode port. Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. • Time and date display field. • Aesthetically pleasing design. • May be powered by 24 voe from the host FACP or by remote power supplies (requires 24 VDC). • Up to 32 FDU-80 annunciators per FACP. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. • Local piezo sounder with alarm and trouble resound. • Semi-flush-mounts to 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. • Surface-mounts to NOTIFIER SBB-3 surface backbox. OPERATION The FDU-80 annunciator provides the FACP with point an- nunciation with full display text on an BO-character LCD dis- play. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. NOTIFIER® is a Honeywell company. July 20, 2004 DN-6820 • D-123 FDU-80 BO-Character Liquid Crystal Display fire Annunciator Section: Annunciators ®@ I California State Fire Marshal 7120-0028:209 LISTED cs 1 oo S635 MEA 245-00-E t I . . µ ._,._ ..... o.:w: . • f ~_q,~;-tGJ~r--, FDU-80 Annunciator The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communica- tions (two in and two return); and two for the 24 VDC regu- lated power. Dip switches control local functions such as: piezo disable, control switches/key switch disable, transmiU receive mode. INSTALLATION The FDU-80 can be semi-flush mounted to a 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three-gang able electrical switch boxes. Alter- nately, an SBB-3 surface backbox is available for surface- mount applications. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED ENCINEElll't: I MANIIFACTUIII'& QUALITY SYSTEMS @) NOTI Fl ER" 12 Clintonville Road, Northford, Connecticut 06472 Made In the U.S.A. DN-6820 • 07/20/04 -Page 1 of 2 ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. 10103 SBB-3 Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush-mount applications. Three-gang surface backbox for surface-mount applications. FDU-80 TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVICE in the EIA-485 loop Terminal Mode Ir FDU-80 FDU-80 EIA-485 Notes: (2-wires) 24VDC (2-wires) Up to 6,000 ft. ( 1828.B m) / back from last device to end of EIA-485 loop FDU-80 Terminal Mode EIA-485 return (2-wires) 1) EIA-485: Maximum of 6,000 feet (1828.B m) cable length from FACP to FDU-80 annunciators and back to FACP (6,000 feet [1828.8 m] total). Circuit is power-limited. 2) Up to 32 FDU-80 annunciators may be used on the EIA-485 circuit. When multiple FDU-80s are used, certain panels will require additional power supplies (refer to panel documentation). 3) Between each FDU-80 annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. 4) On the AFP-300/400, software revision 3.62 or higher is required. MOUNTING TO IACKBOX(ES) The FDU-80 annunciators can be semi-flush-mounted in a three-gang electrical box with a minimum depth of 2.188" (5.556 cm) (NOTIFIER P/N 10103). The FDU-80 annunciators can be mounted in three gangable electrical switch boxes connected together. NOTE: Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. 5.813" (14.764 cm) wide x 4" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (NOTIFIER PIN 10103, shown at right). Page 2 of 2 -DN-6820 • 07/20/04 Mounting Holes (4) FDU-80 flange 0 0 •· ,_;: FIRE'ALARM ANNUNCIAJ"OR, 6 · '.iaiim :~ miit •.·· ... ·· · SYSTEMS ALL NORMAL 11:00 A MON 3/20/00 .. '-. .. . "' 88§8 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST A TE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7120-0028:209 Annunciators Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 Page 1 of 1 Models FDU-80 and *FDU-B0G remote fire annunciators. Units are compact BO-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. *Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: OCTOBER 3, 2006 Listing Expires June 30, 2007 JAMES PARSEG/AN, Supervising Deputy Program Manager @)NOTIFIER® by Honeywell GENERAL The NOTIFIER NOT-BG12LX is a state-of-the-art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for NOTIFIER's addressable FireWarden-100 fire alarm control panel. Because the NOT-BG 12LX is addres- sable, the control panel can display the exact location of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES • Aesthetically pleasing, highly visible, dual-action design. • Meets ADA 5 lb. maximum pull force. • Easily operated (dual-action). • Attractive shape and textured finish. • Mounts, semi-flush, to a standard single-gang (2.125" [5.398 cm] minimum depth), double-gang, or 4.0" (10.16 cm) square electrical box. • When the handle latches in down position, the word "AC- TIVATED" appears at the top of the handle in bright yel- low to clearly indicate the station has been operated. • Key/lock reset; needs only a 1/4-turn to lock/unlock. • Includes Braille text on station handle. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). • Optional trim ring (BG-TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- vided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/O; or semi-flush mount- ing on a standard single-gang, double-gang, or 4.0" ( 10.16 LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. June 15, 2005 DN-7001 • A1-380 NOT-BG12LX Addressable Manual Pull Station for FireWarden-100 Section: Addressable Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 09/686,286 6~~v® ~ LISTED ~ S692 APPROVED California State Fire Marshal 7150-0028:199 The NOT-BG12LX Addressable Manual Pull Station cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. This document is not intended to be used for installation purposes. We try to keep our product Informat1on up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED @)NOTIFIER' by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 ENGINEEIING & MANUFAClUIINC QUALITY SYSTEMS DN-7001 • 06/15/05 -Page t ol 2 Maximum SLC loop current: 230 µA. INSTALLATION The NOT-BG 12LX can be semi-flush mounted into a single- gang, double-gang, or standard 4.0' (10.16 cm) square elec- trical outlet box, or surface mounted to the Model SB-10 or SB-I/O surface backbox. If the NOT-BG12LX is semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4.0' (10.16 cm) or double-gang boxes (not with single-gang boxes). CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bot- tom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action re- sets the handle; closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops. Each manual station, on command from the control panel, sends data to the panel representing the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION NOT-BG12LX Dual-action addressable pull station. Includes key lock/reset feature. SB-10 Surface backbox. SB-I/O BG-TR Surface indoor/outdoor backbox. Optional trim ring. Detail of <=u BREAKAWAYTAB* Back of station without door. I .__ ___ ___.! I Ml! IHl~ij«i! I MJW(O)IDJ JI.II lO«il (C__ ___________ J) CB ,.. .. OTlf'IK"' 0 - ===□- Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2 of 2 -DN-7001• 06/15/05 ~ 12 11 ROTARY DECIMAL SWITCHES LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-0028:199 Page 1 of 1 Boxes/Pull Stations Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-*7161 FAX (203) 484-7309 Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG- 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG- 12SP, NOT-BG12LX, and *NBG-12LXSP fire alarm pull boxes. All units except Model NBG- 12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. • In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12LO, NBG- 12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB- 1/0, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *Rev. 1-06-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 7, 2006 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 (Gj')NOTIFIER® by Honeywell GENERAL The NP-100 and NP-100T addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelec- tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden-100Addressable Fire Alarm Con- trol Panel (FACP). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C}. Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). FEATURES SLC/oop: • Two-wire loop connection. • Unit uses base for wiring. Addressing: • Addressable by device. • Direct Decade 01 -99 (FireWarden-100) entry of ad- dress. Architecture: • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low-profile design. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. Operation: • Withstands air velocities up to 4,000 feet-per-minute (20 m/sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED "blinks" when the unit is addressed (com- municating with the fire panel} and latches on in alarm. Mechanicals: • Sealed against back pressure. • Direct surface mounting or electrical box mounting. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring -included). Other system features: • Fully coated circuit boards and superior RF/transient June 15, 2005 DN-6995 • A 1-310 NP-100 and NP-100T Addressable Photoelectric Detectors Section: Addressable ® California ~ ~t!~::~~e. ~ LISTED 1212-0020.231 APPROVED S1115 MARYLAND State Fire Marshal Permit # 2173 MEA 243-02-E Vol. II NP-1 DOT with B710LPbase protection. • 94-V0 plastic flammability rating. • Low standby current. Options: NP-100 with B710LP base • Remote LED output connection (P/N RA400Z). SPECIFICATIONS Voltage range: 15 -32 voe (peak). Standby current: 300 µA @ 24 voe. LED current: 6.5 mA@ 24 voe (latched "ON"). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B71 OLP base. Height: 2.1" (5.33 cm) installed in B71 OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°c to 49°C (32°Fto 120°F); forNP-100T:0°Cto38°C (32°Fto 100°F). Temperature: 0°c -49°C (32°F -120°F). Relative humidity: 10% -93%, non-condensing. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED @)NOTIFIER~ by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 fNGINEEIING I MANllli1&TIIIING QUALITY SYSTEMS DN-6995 • 06/15/05 -Page 1 of 2 APPLICATIONS Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, espe- cially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-1 OO{T) plug-in, low-profile smoke detectors are de- signed to commercial standards and offer an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches {3.81 cm) deep. Suitable boxes include: • 4.0" (10.16 cm) square box with plaster ring. • 4.0" (10.16 cm) octagonal box. • 3.5" (8.89 cm) octagonal box. • Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T- taps" or branches are permitted for Style 4 (Class 8) wiring. OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP-1 OO(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) with- out sending an alarm level signal. Because of its unipo- lar chamber, the NP-100{T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to a FireWarden-100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100 for record keeping. Page 2 of 2 -DN-6995 • 06/15/05 PRODUCT LINE INFORMATION NP-100 Addressable photoelectric detector; B71 OLP base included: NP-100T Same as NP-100 but with thermal element; B710LP base included: RA400Z Remote LED. Mounts to a single-gang box. B710LP Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1 Plug-in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). 'Prior to 03/28/05, the 8710LP base was sold separately. LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-0028:231 Page 1 of 1 Photoelectric Smoke Detector Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 Models NP-100 and NP-100T photoelectric type smoke detectors. Model NP-100T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 7, 2006 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 @) NOTI Fl ER® by Honeywell GENERAL Four different monitor modules are available for NOTIFIER's FireWarden-100 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke detectors {NZM-100). NMM-100 -The NMM-100 Monitor Module is a standard- sized module (typically mounts to a 4.0' (10.16 cm] square box) that supervises either a Class A (Style D) or Class B {Style B) circuit of dry-contact input devices. NMM-100P -The NMM-100P is a Miniature Monitor Mod- ule (a mere 1.3' (3.302 cm) H x 2.75' (6.985 cm) W x 0.5' (1.270 cm) D) used to supervise a Class B (Style B) cir- cuit. Its compact design allows the NMM-1 00P to be mounted in a single-gang box behind the device it is moni- toring. NZM-100 -The NZM-100 Interface Module is a stan- dard-sized module used to monitor and supervise com- patible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. NDM-100 -The NDM-100 Dual Monitor Module is a stan- dard-sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises two Class B (Style B) circuits of dry-contact input devices. NMM-100 MONITOR MODULE • Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise {EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct Decade 01 -99 {FireWarden-100) entry of ad- dress. • LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. NMM-100 Applications -Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class D) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is re- June 15, 2005 DN-6999 • A1-350 Addressable Monitor Modules for the FireWarden-100: NMM-100, NMM-1 00P, NZM-100, NDM-100 ® LISTED S635 Section: Addressable MEA 72-01-E Vol. II (except NDM-100) i . . <§> APPROVED () 0 0 0 0 NMM-100 and NZM-100 California State Fire Marshal 7300-0028:230 (except NDM-100) quired for supervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. NMM-100 Operation -Each NMM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm {subject to current limitations on the loop). NMM-100 Specifications Nominal operating voltage: 15 to 32 voe. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 µA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4.0' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4.0' (10.16 cm) square x 2.125' (5.398 cm) deep box. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ISO 9001 CERTIFIED @)NOTIFIER~ by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 ENGINEEIINli I MANDFACTIIIINli QUALITY SYSTEMS DN-6999 • 06/15/05 -Page 1 of 3 NMM-I00P MINI MONITOR MODULE • Built-in type identification automatically identifies this de- vice as a monitor module to the FireWarden-100. • Powered directly by two-wire SLC Loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address (01-99 for FireWarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-1 00P is intended for use in in- telligent, two-wire systems where the individual address of each module is selected using rotary switches. It pro- vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. ~~:1 ADDRESS ~j I LOOP □ 10 5 9 8 7 6 9 8 7 6 TENS ONES LJF ~,i l~I f ~ s: I-! ' ~ 0 UJ Q, (.) ..,J ..,J UJ • s ID "0 ct: I.' >,: ,,, s: p, co 1\] NMM-100P Applications -Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact devices. May also be used to monitor nor- mally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Cir- cuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. NMM-100P Operation -Each NMM-100P uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). NMM-100P Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 µA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75' (6.985 cm) wide x 0.5' (1.270 cm) deep. Wire length: 6.0' {15.24 cm) minimum. Page 2 of 3 -DN-6999 • 06/15/05 NZM-100 INTERFACE MODULE • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source (resettable). • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address (01-99 for FireWarden-100). • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in- telligent, addressable systems, where the individual ad- dress of each module is selected using built-in rotary switches. This module allows intelligent panels to inter- face and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com- patible with the module. NZM-100 Applications -Use the NZM-100 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D {class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELA across terminals 8 and 9 for Style D application. NZM-100 Operation -Each NZM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status {open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm {subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 µA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F {0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' {11.43 cm) high x 4.0' {10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125' (5.398 cm) deep box. NDM-100 DUAL MONITOR MODULE • Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. • Powered directly by the two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address 01 -99 (FireWarden-100) uses two addresses per module. • LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independent two-wire fault-toler- ant Initiating Device Circuits (IDCs) at two separate, con- secutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. NDM-100 Applications -Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, waterflow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. NDM-100 Operation -Each NDM-100 uses two of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NDM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 µA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125' (5.398 cm) deep box. Accessories: SMB500 electrical box. INSTALLATION NMM-100, NZM-100, and NDM-100 modules mount di- rectly to a standard 4.o• (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and in- stallation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances and regulations. ARCHITECTS' /ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module. NZM-100 Two-wire detector monitor module. NDM-100 Dual monitor module. SMB500 Optional surface-mount backbox. MOUNTING DIAGRAMS for slandard-sized modules DN-6999 • 06/15/05 -Page 3 of 3 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING • BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-0028:230 Page 1 of 1 Misc. Devices/Control Unit Accessories Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. 15-32 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-0075:185 10-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: JUNE 7, 2006 DIANE K. AREND, Senior Deputy Program Manager Listing Expires June 30, 2007 ,,,, COOPER Wheelock Series AS Audible Strobe Appliances and Series AH Auddibles SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. <§> APPROVED E5946 151-92-E 7125-0785:131 S5391 Features • Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADNNFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/11 0cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones • Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires For Weatherproof Series AS, See Datasheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. _A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range·. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" Is the newest tennlnology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Table 2: dBA Ratings for 12 VDC and 24 VDC Series Model Input Regulated Strobe AS/AH 12 and 24 VDC Audible Number Voltage Voltage Range Candela (cd) VDC VDC/FWR Reverberant Anechoic dBA AS-24MCW 24 16.0 -33.0 1513on51110 Description Volume Per UL 464 dBA @10 ft. @10 ft. AS-24MCCH 24 16.0 -33.0 115/177 High 91 99 AS-241575W 24 16.0 -33.0 15 (75 on Axis) Continuous Medium 88 95 Hom AS-121575W 12 8.0-17.5 15 (75 on Axis) Low 83 90 AS-24MCC 24 16.0 -33.0 15/30/75/95 High 87 99 AS-24MCWH 24 16.0 -33.0 135/185 Code 3 Horn Medium 84 95 ASWP-2475W 24 16.0 -33.0 75@-31°F Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Celling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) 24vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Wall Mount Audible Audible 12 VDC Models Strobe Table 4: Average Current* (AMPS) For Series ASWP# High dBA Medium dBA Low dBA AH-12 AS-121575W Voltage Setting Setting Setting 12 vdc 0.163 0.260 (99) dBA (95) dBA (90) dBA High (99) 24.0 VDC 0.128 0.105 0.098 ciBA UL max* 0.192 0.320 UL Max* 0.168 0.155 0.150 Med (95) 12 vdc 0.076 0.195 dBA UL max* 0.108 0.275 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range ( 16-33v Low (90) 12 vdc 0.039 0.175 for 24v units). For strobes the UL max current is usually at the minimum dBA UL max* 0.058 0.265 listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams# SERIES AS APPLIANCES NON-SYNCHRONIZED FROM PRECEDING + APPLIANCE -JT'-"'- OR FACP TO NEXT ~ APPLIANCE OR EOLR + SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/24-SCP and PS-12/24-SMP F A C p OUTPUTS 1-4 4-CLASS ·5· OR 2-CLASS "A" Serles PS-12/24-SCP or PS-12/24-SMP EOLR SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE •10.NA.L eo,ou" ncTa;"N'------' Specifications and Ordering Information SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE F A C p Slrol.>e NAC Circuit Audible NAC Circuit SM SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A C p DSM Interconnecting wiring shown. Maximum of twenty (20) • For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-BMC. Order Strobe Non-Syncw/SM, 24 12 Wall Ceiling Agency Approvals Model Number Code Candela Sync DSM or VDC VDC Mount Mount Mounting Options*..., PS-24-8MC UL MEA CSFM FM BFP IAS-24MCW-FR 9024 15I3on5I110 X X X -X -A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCW-FW 9025 15I3on5I11 o X X X -X -A,B,D,E,F,G,H,J,N,O,R,X X X X X X IAS-24MCWH-FR 3468 135/185 X X X -X -A,B,D,E,F,G,H,J,N,O,R,X X X X X . AS-24MCWH-FW 3469 135/185 X X X -X -A,B,D,E,F,G,H,J,N,O,R,X X X X X • IAS-241575W-FR 7405 15 (75 on Axis) X X X -X -A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-121575W-FR 7410 15 (75 on Axis) X X -X X -A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCC-FR 3161 15I3on5I95 X X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X . -- AS-24MCC-FW 3162 15/30/7 5/95 X X X --X A,B,D,E,F,G,H,J,N,O,R,X X X X X . 14S-24MCCH-FW 3467 115/177 X X X --X A,B,D,E,F,G,H,J,N,O,R,X X X X X . ASWP-2475W-FR** 9012 75@-31°F X X X -X -I (see Data Sheet S9004) X X X X X ;A.H-24-R 7892 -X X X -X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-24-W 7893 -X X X -X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X AH-12-R 7891 -X X -X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X IAH-12-W 7894 -X X -X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X IAH-24WP-R** 7416 -X X X -X X K X X X X IAH-12WP-R** 7415 -X X -X X X K X X X X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alann Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30(75/110 or 135/185 candela for wall mount and 15/30f75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock PS-24-BMC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com NEMA I ,'. ht5 · 14 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA 58100 AS/AH 06/06 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-0785: 131 Page 1 of 2 Fire Alarm Devices for the Hearing-Impaired Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. Models AS-2415C, -2430C, -24 75C and -241 00C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix Care for ceiling mount only. Units with suffix Ware for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. Electrical: Candela: 8-17.5/16-33 VDCNFR 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100: 1 00cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 11 0cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix-Ware for wall mount only. Models with suffix -C are for ceiling mount only. •Rev. 06-13-06 MARKING: Listing No. 7125-0785:131 Page 2 of 2 Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785: 132). Refer to listee's Installation Instruction Manual for details. NOTE: These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. •Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager -" COOPER Wheelock Series RSS and RSSP Strobes and Strobe Plates Series RSS Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/11 0cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/7 5/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-BMC Power Supplies with the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. ®,,."::_1' ~-·;,-I MEA S5391 151-92-E 7125-0785:141 730o--0785:154 <8> APPROVED FIRE Series RSS Features 'Ff~_E 'i l'./11: • , !•··•••<. ♦ C..-·····'"'·"•· .. _. '--•·· l i 'FIRE 'I Series RSSWP RSS Round Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/11 0cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 voe models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or power sup- plies with built-in sync protocol Fast installation with IN/OUT screw tenninals using #12 to #18 AWGwire For Weatherproof Sen"es RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed in bold capital letters. A. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH homs are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" Is the newest terminology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current" RSS/RSSP -Wall Mount RSS -Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS/RSSP • RMS current ratings are per UL average RMS method. UL max current Wall Mount 24VDC rating is the maximum RMS current within the listed voltage range (16-33v Models 121575W for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at 12 vdc 0.152 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. UL max* 0.255 Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH,NH,HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT FACP DSM SYNC+ 0 ·0 .our 1 MINUS I 0+ 0 _ AUDIBL MINUS 2 ~--t-<l/l ♦IN2 L-------':'TROBE NAC CIRCUIT RETURN • UUT2 RSS RSS Wiring Diagrams # SERIES RSS/RSSP APPLIANCE FROM PRECEDING ~ -~,,~,~~ APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + TO NEXT ~ APPLIANCE OR EOLR SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES F A C p Strobe NAC Cir. Strobe NAC Cl . DSM Ill DSM Interconnecting wiring shown. Maximum of twenty (20) TROBE/PLATE ASSEMBLY UDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM ---+h-~ ~--APPLIANCE PRECEDING ": :::::::-,~ : OR EOLR APPLIANCE, SYNC MODULE. POWER SUPPLY OR FACP + _ 0 + _ STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY ~:~~EDING + -----~ ~----+ TO NFXT APPLIANCE UH -APPLIANCE FACP OR EOLR ~~~~m,Nc + --1 r --- ~~i.~~"s;~~F; --T1 l r -- SllPP\.Y OR FAC.P STROBE APPLIANCE +mNFXT STRORF. OR -F.01.R • For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24-BCP and P84333 for PS-12/24-BMP. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT F A C p Strobe NAC Circuit SM + STROBE • STROBE +Audibl EOLR ·Audibl SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-SCP or PS-12/24-SMP F A C p Serles PS-12/24-BMP OlITPUTS 1-4 4-CLASS ·s· OR 2-CLASS "A" Series PS-12/24-BM EOLR Order Wall Ceiling Non-Strobe 24 12 Color Color Square Agency Approvals Model Code Mount Mount Sync Candela VDC VDC RED WHITE Mounting Options••• RSS-24MCW-FR 940 X . X 15/30/75/110 X . X -B,D,E,F,G,H,J,N,O,R,X RSS-24MCW-FW 9401 X -X 15/30/75/110 X --X B,D,E,F,G,H,J,N,O,R,X RSS-241575W-FR 7471 X -X 15 (75 on Axis) X -X -B,D,E,F,G,H,J,N,O.R.X RSS-241575W-FW 7788 X -X 15 (75 on Axis) X --X B,D,E,F,G,H,J,N,O,R,X RSS-121575W-FR 7476 X -X 15 (75 on Axis) -X X -B,D,E,F.G,H,J,N,O,R,X RSS-121575W-FW 7468 X -X 15 (75 on Axis) -X -X B,D,E,F,G,H,J,N,O,R,X RSS-24MCC-FW 3158 -X X 15/30/75/95 X --X B,D,E,F,G,H,J,N,O,R,X RSS-24MCC-FR 3157 -X X 15/30/75/95 X -X -B,D,E,F,G,H,J,N,O,R,X RSS-24MCCR-FW 3160 -X X 15/30/7 5/95 X --X B,D,E,F,G,H,J,N,O,R,X RSS-24MCCH-FW 3461 -X X 115/177 X --X B,D,E,F,G,H,J,N,O,R,X RSS-24MCCHR-FW 3463 -X X 115/177 X --X B,D,E,F,G,H,J,N,O.R.X RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R.X RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X RSSWP-2475W-FR** 9013 X -X 180@ 77°F X X X -B,D,E,F,G,H,J,N,O,R,X 75@-31°F RSSWP-2475W-FW** 3034 X -X 180@ 77°F X X -X B,D,E,F,G,H,J,N,O,R,X 75@ -31 °F RSSP-121575W-FR 7798 X -X 15 (75 on Axis) -X X -D,E,Z RSSP-24MCW-FR 9402 X -X 15/30/75/110 X -X -D,E,Z RSSP-241575W-FR 7793 X -X 15 (75 on Axis) --X -D,E,Z All models sync with Wheelock SM, DSM or PS-12/24-BCP or PS-12/24-BMP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. or Round UL MEA CSFM FM BFP Square· X X X X X Square X X X X X Square X X X X X Square X X X X X Square X X X X X Square X X X X X Square X X X X . Square X X X X . Round X X X X . Square X X X X . Round X X X X . Square X X X X . Square X X X X . Square X X X X . Square X X X X . Square X X X X X Square X X X X X Square X X X X X *PENDING Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one ( 1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30n5/11 0cd or 135/185cd for wall mount and 15/30n5/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. lfrequired, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. _,, COOPER Wheelock 273 Branch port Avenue Long Branch, NJ 077 40 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com MENIA l,~ttn-14 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S0410 RSS/RSSP 11/06 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-0785:141 Page 1 of 1 Fire Alarm Devices for the Hearing Impaired Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS-MCC, *ZRS-MCW, *ZRS-MCCH and *ZRS-MCWH. Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. Electrical Candela Flash rate 12 = 8-17.5VDC/FWR OR 24 =16-33VDC/FWR 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=11 0cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS-MCW: Selectable 15cd, 30cd, 75cd or 110cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS-MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS-MCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS-MCCH: Selectable 115cd, 177cd 60 flashes/minute In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. Listee's name, model number, electrical/candela rating, and UL label. Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785: 132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By: DECEMBER 13, 2006 KEN VOLLENWEIDER, Senior Deputy Program Manager Listing Expires June 30, 2007