Loading...
HomeMy WebLinkAbout5490 GRAND PACIFIC DR; ; FPC2017-0189; PermitPERMIT REPORT C c:ity of Carlsbad H AG pwm I I Print Date: 10/15/2021 Permit No: FPC2017-0189 Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: 2122710200 $14,074,332.00 Track #: Lot #: Project #: DEV14056 Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 07/13/2017 Issued: 08/28/2017 Finaled Close Out: 08/11/2021 Inspector: Final Inspection: 5490 GRAND PACIFIC DR, CARLSBAD, CA 92008 Status: Closed - Finaled FIRE-Construction Commercial Work Class: Fire Sprinklers Project Title: WESTIN HOTEL & TIMESHARE Description: WESTIN HOTEL -SPRINKLER (NEW) >100 HEADS 1/9 ADDITIONAL RISERS 4-LEVEL /I 72 ROOMS Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST POWAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 FIRE NFPA 13 System> 100 heads (includes 1 riser) $1,188.00 Total Fees: $2,020.00 Total Payments To Date: $2,020.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I I I Western Fire Protection Inc. I I WESTIN HOTEL 5490 GRAND PACIFIC DRIVE I CARLSBAD, CA 92008 I Fire Sprinkler Hydraulic Calculations I I I I I I I FPC20I7-0189 1 5490 GRAND PACIFIC DR 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Hotel 3 SR#: (Assigned upon plan submittal) PROJECT ADDRESS: The Crossings Drive south of Stewart Road CITY: Carlsbad PHONE: ( 858 ) 513-4949 (Western Fire Protection) FAX NUMBER: I Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): The Crossings Drive south of Stewart Road TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 63 PSI Hydrant Number (if applicable): H60365 Elevation of test: 229 est. Feet Date/Time of Test': Pitot Tube Reading:_________________ Psi Corresponding Flow: GPM Total Flow: 8,000 GPM Residual Pressure 22 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. 'Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name:2n*,f_.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signat / Title/O Manager Date: 02/10/2017 I 1 I I I I I I I I I I I L I I I I I I I I ROCKEFELLER R D Hotel Fire- Flow, I I 80 RD 8 0 & co I, LJII1Im/ I Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name : Westin Hotel (Hotel 3) Basement Building Location System Contract Data File : Basement.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I I I I I 11 I I I I I Water Supply Curve C Western Fire Protection Inc Westin Hotel (Hotel 3) Basement City Water Supply: Demand: Cl - Static Pressure : 63 Dl - Elevation : -1.263 C2 - Residual Pressure: 22 D2 - System Flow : 400.003 C2 - Residual Flow : 8000 D2 - System Pressure : 48.096 Hose ( Demand) : 250 D3 - System Demand : 650.003 Safety Margin : 14.509 150 140 130 p120 R11° E10° 590 s 8° U70 R60 D2 E 50 40 - 30 - - C2 20 10 10t2000 3000 4000 5000 6000 7000 8000 9000 FLOW( N"1.85) - Page Date Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 — — = — — — — M — = M _. — - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) Basement Date Fitting Legend Abbrev. Name 1/2 3/4 1 1% 11/2 2 2½ 3 31/z 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90 Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90Tee-BranchGry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Page 3 Western Fire Protection Inc Westin Hotel (Hotel 3) Basement Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Si -0.917 5.6 12.39 na 19.71 0.15 130 7.0 S2 -0.917 5.6 11.25 na 18.78 0.15 48 7.0 -0.917 12.39 na S3 -0.917 5.6 12.46 na 19.77 0.15 130 7.0 S4 -0.917 5.6 12.13 na 19.5 0.15 130 7.0 S5 -0.917 5.6 12.16 na 19.53 0.15 130 7.0 12.5 na 2 -0.917 S6 -0.917 5.6 12.85 na 20.08 0.15 130 7.0 S7 -0.917 5.6 14.74 na 21.5 0.15 121 7.0 S8 -0.917 5.6 16.52 na 22.76 0.15 121 7.0 S9 -0.917 5.6 18.87 na 24.33 0.15 121 7.0 Sb -0.917 5.6 21.27 na 25.83 0.15 121 7.0 Sli -0.917 5.6 21.19 na 25.78 0.15 121 7.0 4 -0.917 21.31 na S12 -0.917 5.6 S13 -0.917 5.6 21.45 22.05 na na 25.93 26.3 0.15 0.15 121 121 7.0 7.0 S14 -0.917 5.6 23.4 na 27.09 0.15 121 7.0 S15 -0.917 5.6 24.33 na 27.62 0.15 130 7.0 S16 -0.917 5.6 24.39 na 27.66 0.15 130 7.0 ' S17 -0.917 5.6 24.71 na 27.84 0.15 130 7.0 3 -0.917 23.22 na 5 -0.917 23.53 na 6 -0.917 24.83 na TR -0.917 37.28 na BRB -4.083 44.6 na SPL -1.167 43.52 na RRI -1.167 44.21 na RR2 -1.167 . 44.57 na UG1 -1.167 44.88 na UG2 -4.0 46.55 na FDC -4.0 46.65 na 250.0 UG3 -4.0 46.83 na 47.03 na I UG4 -4.0 TEST 2.0 48.1 na The maximum velocity is 16.33 and it occurs in the pipe between nodes S9 and 3 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel (Hotel 3) Basement Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I Si 19.71 2.157 0.0 0.500 12.391 K Factor = 5.60 to 120.0 0.0 0.0 0.0 1 19.71 0.0040 0.0 0.500 0.002 Vel = 1.73 0.0 I 19.71 12.393 K Factor = 5.60 S2 18.78 1.049 T 5.0 4.875 11.249 K Factor = 5.60 I to 1 18.78 120.0 0.1158 0.0 0.0 5.000 9.875 0.0 1.144 Vel = 6.97 1 19.71 2.157 0.0 5.500 12.393 to 120.0 0.0 0.0 0.0 S3 38.49 0.0131 0.0 5.500 0.072 Vel = 3.38 I S3 19.78 2.157 0.0 1.083 12.465 K Factor = 5.60 to 120.0 0.0 0.0 0.0 2 58.27 0.0277 0.0 1.083 0.030 Vel = 5.12 I 0.0 58.27 12.495 K Factor= 16.48 S4 19.50 2.157 0.0 9.667 12.125 K Factor= 5.60 I to 120.0 0.0 0.0 0.0 S5 19.5 0.0037 0.0 9.667 0.036 Vel = 1.71 S5 19.53 2.157 T 12.307 12.625 12.161 K Factor 5.60 120.0 0.0 12.307 0.0 I to 2 39.03 0.0134 0.0 24.932 0.334 Vel = 3.43 2 58.26 2.157 0.0 4.917 12.495 to 120.0 0.0 0.0 0.0 S6 97.29 0.0726 0.0 4.917 0.357 Vel = 8.54 I S6 20.08 2.157 21 8.615 9.792 12.852 K Factor = 5.60 to 120.0 0.0 8.615 0.0 S7 117.37 0.1027 0.0 18.407 1.890 Vel = 10.30 I S7 21.50 2.157 0.0 12.667 14.742 K Factor= 5.60 to 120.0 0.0 0.0 0.0 S8 138.87 0.1401 0.0 12.667 1.775 Vel = 12.19 I S8 22.76 2.157 0.0 12.667 16.517 K Factor =5.60 to 120.0 0.0 0.0 0.0 S9 161.63 0.1856 0.0 12.667 2.351 Vel = 14.19 S9 24.33 2.157 T 12.307 5.792 18.868 K Factor= 5.60 to I 120.0 0.0 12.307 0.0 3 185.96 0.2406 0.0 18.099 4.354 Vel = 16.33 0.0 I 185.96 23.222 K Factor= 38.59 S1O 25.83 2.157 0.0 6.083 21.273 K Factor 5.60 to 120.0 0.0 0.0 0.0 4 25.83 0.0062 0.0 6.083 0.038 Vet = 2.27 I 0.0 25.83 21.311 KFactor= 5.60 SII 25.78 2.157 T 12.307 6.417 21.194 K Factor 5.60 to I 120.0 0.0 12.307 0.0 4 25.78 0.0062 0.0 18.724 0.117 Vel = 2.26 4 25.83 2.157 0.0 6.083 21.311 to 120.0 0.0 0.0 0.0 I S12 51.61 0.0225 0.0 6.083 0.137 Vel = 4.53 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel (Hotel 3) Basement Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.C. or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I S12 25.93 2.157 0.0 12.667 21.448 K Factor= 5.60 to 120.0 0.0 0.0 0.0 S13 77.54 0.0477 0.0 12.667 0.604 Vel = 6.81 I S13 26.30 2.157 T 12.307 5.792 22.052 K Factor = 5.60 to 120.0 0.0 12.307 0.0 5 103.84 0.0818 0.0 18.099 1.481 Vel = 9.12 0.0 I 103.84 23.533 KFactor 21.41 S14 27.09 2.157 T 12.307 6.875 23.402 KFactor = 5.60 to 120.0 0.0 12.307 0.0 I 5 27.09 0.0068 0.0 19.182 0.131 Vel = 2.38 0.0 27.09 23.533 K Factor = 5.58 S15 27.62 2.157 0.0 8.667 24.328 K Factor = 5.60 I to 120.0 0.0 0.0 0.0 S16 27.62 0.0072 0.0 8.667 0.062 Vel = 2.43 I S16 to 27.66 2.157 120.0 T 12.307 0.0 4.875 12.307 24.390 0.0 K Factor= 5.60 6 55.28 0.0255 0.0 17.182 0.438 Vel = 4.85 0.0 55.28 24.828 K Factor= 11.09 I S17 27.84 2.157 T 12.307 3.792 24.712 K Factor 5.60 to 120.0 0.0 12.307 0.0 6 27.84 0.0072 0.0 16.099 0.116 Vel = 2.44 I 0.0 27.84 24.828 K Factor= 5.59 3 185.96 3.26 0.0 9.667 23.222 120.0 0.0 0.0 0.0 I to 5 185.96 0.0322 0.0 9.667 0.311 Vel = 7.15 5 130.93 3.26 0.0 15.000 23.533 to 120.0 0.0 0.0 0.0 I 6 316.89 0.0863 0.0 15.000 1.295 Vel = 12.18 6 83.11 3.26 51 33.599 60.208 24.828 to 120.0 0.0 33.599 0.0 TR 400.0 0.1328 0.0 93.807 12.454 Vel = 15.37 I TR 0.0 3.26 B 13.44 4.500 37.282 to 120.0 I 6.72 40.319 1.371 BRB 400.0 0.1328 T 20.159 44.819 5.951 Vel = 15.37 I BRB 0.0 6.357 J 31.433 2.917 44.604 to 120.0 0.0 31.433 -1.263 SPL 400.0 0.0052 0.0 34.350 0.177 Vel = 4.04 I SPL 0.0 6.357 51 62.867 72.667 43.518 to 120.0 0.0 62.867 0.0 RRI 400.0 0.0051 0.0 135.534 0.696 Vel = 4.04 RRi 0.0 6.357 31 37.72 19.583 44.214 I to 120.0 B 12.573 50.293 0.0 RR2 400.0 0.0051 0.0 69.876 0.359 Vel = 4.04 RR2 0.0 6.357 31 37.72 22.833 44.573 I to 120.0 0.0 37.720 0.0 UG1 400.0 0.0051 0.0 60.553 0.311 Vel = 4.04 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 6 Westin Hotel (Hotel 3) Basement Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I UG1 0.0 8.249 F 10.571 248.875 44.884 to 120.0 2E 42.282 52.853 1.227 UG2 400.0 0.0014 0.0 301.728 0.435 Vel = 2.40 I UG2 0.0 7.98 G 5.317 75.167 46.546 to 140.0 0.0 5.317 0.0 FDC 400.0 0.0013 0.0 80.484 0.103 Vel = 2.57 FDC 250.00 7.98 T 46.522 10.208 46.649 Qa = 250 I to 140.0 0.0 46.522 0.0 UG3 650.0 0.0031 0.0 56.730 0.178 Vel = 4.17 UG3 0.0 11.65 3E 95.65 125.167 46.827 I to 140.0 2T 141.704 283.408 0.0 UG4 650.0 0.0005 3F 46.054 408.575 0.203 Vel = 1.96 UG4 0.0 11.65 3E 108.672 57.750 47.030 to 150.0 F 17.441 206.611 0.951 * * Fixed Loss = 3.55 I TEST 650.0 0.0004 T 80.498 264.361 0.115 Vel = 1.96 Zaf 0.0 0.0 650.00 48.096 K Factor = 93.73 I I I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I 1 I I I I I I I 1 I I I I I Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name Westin Hotel (Hotel 3)1st Floor Building Location System Contract Data File : Hotel 31st Floor—King Room.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - Water Supply Curve C Western Fire Protection Inc Westin Hotel (Hotel 3)1st Floor City Water Supply: Cl - Static Pressure : 63 C2 - Residual Pressure: 22 C2 - Residual Flow : 8000 = - - M - - - - - - Page Date Demand: Dl - Elevation : 3.032 D2 - System Flow : 116.683 D2 - System Pressure : 44.512 Hose ( Demand) :100 D3 - System Demand : 216.683 Safety Margin : 18.437 150 140 130 p120 R 11 E10° 90 580 U70 R 60 E 50 -Dr- 40 30 - - C2 20 10 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - = - - - - — Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3)1st Floor Date Fitting Legend Abbrev. Name 1/2 3/4 1 1Y4 11/2 2 21/2 3 3½ 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 C NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90Tee-BranchGry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 T NFPA 139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Fire Protection Inc Page 3 I Westin Hotel (Hotel 3)1st Floor Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. I Si 9.0 5.6 12.65 na 19.92 0.1 8 7.0 S2A 9.0 5.6 12.76 na 20.0 0.1 200 7.0 I S211 9.0 5.6 S3 9.0 5.6 14.71 23.66 na na 21.48 27.24 0.1 0.1 150 15 7.0 7.0 S4 9.0 5.6 25.08 na 28.04 0.1 144 7.0 9.0 12.98 na A 9.0 14.33 na B 9.0 16.51 na I 3 9.0 25.45 na 400 9.0 26.96 na 401 9.0 27.0 na 403 9.0 27.02 na I TR 9.0 33.84 na BR113 4.0 37.47 na BR48 34.042 24.66 na 408 39.0 HV3 47.792 22.7 18.96 na na I H4 47.792 19.05 na HV4 47.792 19.44 na TS2 47.792 19.5 na SPL2 -1.167 40.77 na I RR1 -1.167 40.85 na RR2 -1.167 40.88 na UG1 -1.167 40.91 na I UG2 -4.0 FDC -4.0 42.19 42.2 na na 100.0 UG3 -4.0 42.22 na UG4 -4.0 42.25 na TEST 2.0 44.51 na I it in between B 400 and The maximum velocity is 20.69 and occurs the pipe nodes I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel (Hotel 3)1st Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I Si 19.92 1.101 E 3.825 1.000 12.653 K Factor= 5.60 to 150.0 0.0 3.825 0.0 1 19.92 0.0676 0.0 4.825 0.326 Vel = 6.71 0.0 I 19.92 12.979 K Factor = 5.53 S2A 20.00 1.101 2E 7.65 6.000 12.755 K Factor = 5.60 150.0 T 9.563 17.212 0.0 I to A 20.0 0.0680 0.0 23.212 1.579 Vel = 6.74 0.0 20.00 14.334 K Factor = 5.28 I S213 21.48 1.101 2E 7.65 6.000 14.711 K Factor =5.60 to 150.0 T 9.563 17.212 0.0 B 21.48 0.0777 0.0 23.212 1.803 Vel = 7.24 0.0 I 21.48 16.514 KFactor= 5.29 S3 27.24 1.101 E 3.825 1.500 23.661 K Factor = 5.60 to 150.0 T 9.563 13.387 0.0 27.24 0.1204 0.0 14.887 1.793 Vel = 9.18 I3 0.0 27.24 25.454 K Factor = 5.40 S4 28.04 1.101 E 3.825 1.875 25.080 K Factor= 5.60 I to 150.0 T 9.563 13.387 0.0 403 28.04 0.1272 0.0 15.262 1.941 Vel = 9.45 0.0 1 28.04 27.021 K Factor = 5.39 1 19.92 1.101 E 3.825 16.250 12.979 to 150.0 0.0 3.825 0.0 A 19.92 0.0675 0.0 20.075 1.355 Vel = 6.71 l A 20.00 1.101 0.0 8.917 14.334 to 150.0 0.0 0.0 0.0 B 39.92 0.2445 0.0 8.917 2.180 Vel= 13.45 I B 21.48 1.101 T 9.563 9.708 16.514 to 150.0 0.0 9.562 0.0 400 61.4 0.5419 0.0 19.270 10.443 Vel = 20.69 0.0 I 61.40 26.957 K Factor = 11.83 3 27.24 1.101 T 9.563 3.292 25.454 150.0 0.0 9.562 0.0 I to 401 27.24 0.1205 0.0 12.854 1.549 VeI = 9.18 0.0 27.24 27.003 K Factor = 5.24 1 400 61.40 2.635 0.0 6.000 26.957 to 150.0 0.0 0.0 0.0 401 61.4 0.0077 0.0 6.000 0.046 Vel = 3.61 401 27.24 2.635 0.0 1.167 27.003 I to 150.0 0.0 0.0 0.0 403 88.64 0.0154 0.0 1.167 0.018 Vel = 5.22 403 28.04 2.635 71 87.128 156.833 27.021 I to 150.0 T 24.894 112.022 0.0 TR 116.68 0.0254 0.0 268.855 6.818 Vel = 6.86 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 I Westin Hotel (Hotel 3)1st Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I TR 0.0 2.635 E 12.447 5.833 33.839 to 150.0 T 24.894 51.861 2.166 BR1B 116.68 0.0254 B 14.521 57.694 1.463 Vel = 6.86 I BR1B 0.0 4.26 21 18.434 37.000 37.468 to 120.0 0.0 18.434 -13.011 BR413 116.68 0.0037 0.0 55.434 0.204 Vel = 2.63 BR413 0.0 ,4.26 21 18.434 32.542 24.661 I to 120.0 0.0 18.434 -2.147 408 116.68 0.0037 0.0 50.976 0.188 Vel = 2.63 408 0.0 4.26 I 9.217 8.792 22.702 I to 120.0 0.0 9.217 -3.808 HV3 116.68 0.0037 0.0 18.009 0.067 Vel = 2.63 HV3 0.0 4.26 J 21.067 4.250 18.961 ' to 120.0 0.0 21.067 0.0 H4 116.68 0.0037 0.0 25.317 0.093 Vel= 2.63 H4 0.0 4.26 I 9.217 73.833 19.054 120.0 J 21.067 30.284 0.0 I to HV4 116.68 0.0037 0.0 104.117 0.385 Vel = 2.63 HV4 0.0 4.26 I 9.217 8.208 19.439 to 120.0 0.0 9.217 0.0 TS2 116.68 0.0037 0.0 17.425 0.064 Vet = 2.63 I TS2 0.0 6.357 31 37.72 58.125 19.503 to 120.0 J 31.433 69.153 21.204 SPL2 116.68 0.0005 0.0 127.278 0.067 Vel = 1.18 ' SPL2 0.0 6.357 51 62.867 72.667 40.774 to 120.0 0.0 62.867 0.0 RRI 116.68 0.0005 0.0 135.534 0.072 Vel= 1.18 ' RR1 0.0 6.357 31 37.72 19.583 40.846 to 120.0 B 12.573 50.293 0.0 RR2 116.68 0.0005 0.0 69.876 0.036 Vel = 1.18 RR2 0.0 6.357 31 37.72 22.833 40.882 I to 120.0 0.0 37.720 0.0 UG1 116.68 0.0005 0.0 60.553 0.032 Vel = 1.18 UGI 0.0 8.249 F 10.571 248.875 40.914 ' to 120.0 2E 42.282 52.853 1.227 UG2 116.68 0.0001 0.0 301.728 0.045 Vet = 0.70 UG2 0.0 7.98 G 5.317 75.167 42.186 I FDC to 140.0 116.68 0.0001 0.0 0.0 5.317 80.484 0.0 0.010 Vet = 0.75 FDC 100.00 7.98 T 46.522 10.208 42.196 Qa = 100 to 140.0 0.0 46.522 0.0 UG3 216.68 0.0004 0.0 56.730 0.023 Vel = 1.39 I UG3 0.0 11.65 3E 95.65 125.167 42.219 to 140.0 2T 141.704 283.408 0.0 UG4 216.68 0.0001 3F 46.054 408.575 0.027 Vel = 0.65 I UG4 0.0 11.65 3E 108.672 57.750 42.246 to 150.0 F 17.441 206.611 2.250 * * Fixed Loss = 4.849 I TEST 216.68 0.0001 T 80.498 264.361 0.016 Vel = 0.65 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 6 Westin Hotel (Hotel 3)1st Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 Zaf 0.0 0.0 216.68 44.512 KFactor= 32.48 1 1 I I 1 I 1 I 1 I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name : Westin Hotel (Hotel 3) Exhibition Hall Building Location System Contract Data File Hotel 3—Exhibition HalI.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - -U lu_U - - -__I Water Supply Curve C Western Fire Protection Inc Page Westin Hotel (Hotel 3) Exhibition Hall Date City Water Supply: Demand: Cl - Static Pressure : 63 Dl - Elevation : 11.694 C2 - Residual Pressure: 22 D2 - System Flow : 279.294 C2 - Residual Flow : 8000 D2 - System Pressure : 61.000 Hose ( Demand) : 100 D3 - System Demand : 379.294 Safety Margin : 1.854 150 140 130 p120 R° E10° S90 80 U 70 R 60 E 5 D3-- 40 30 - .z:::z:::I:III: C2 20 10 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - - = IMI- - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) Exhibition Hall Date Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11,4 2 21,4 3 31,4 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Fire Protection Inc Page 3 Westin Hotel (Hotel 3) Exhibition Hall Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. I Si 29.0 5.6 16.14 na 22.5 0.1 225 7.0 S2 29.0 5.6 16.27 na 22.59 0.1 225 7.0 I S3 29.0 5.6 S4 29.0 5.6 16.53 17.43 na na 22.77 23.38 0.1 0.1 225 225 7.0 7.0 S5 29.0 5.6 16.83 na 22.97 0.1 225 7.0 S6 29.0 5.6 16.9 na 23.02 0.1 225 7.0 S7 29.0 5.6 17.15 na 23.19 0.1 225 7.0 S8 29.0 5.6 17.67 na 23.54 0.1 225 7.0 I S9 29.0 5.6 17.78 na 23.62 0.1 225 7.0 S1O 29.0 5.6 17.86 na 23.67 0.1 225 7.0 Sil 29.0 5.6 18.13 na 23.84 0.1 225 7.0 S12 29.0 5.6 18.67 na 24.2 0.1 225 7.0 I 300 29.0 18.79 na 301 29.0 18.95 na 302 29.0 20.02 na I 303 29.0 304 29.0 30.11 35.75 na na TR 9.0 49.02 na BR1 4.0 54.51 na SPL -1.167 56.85 na RR1 -1.167 57.2 na I RR2 -1.167 57.39 na UG1 -1.167 57.55 na UG2 -4.0 59.0 na I FDC -4.0 UG3 -4.0 59.05 59.12 na na 100.0 UG4 -4.0 59.19 na I TEST 2.0 61.0 na I I I I I I I The maximum velocity is 16.43 and it occurs in the pipe between nodes 302 and 303 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel (Hotel 3) Exhibition Hall Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv.. Ln. Total Pf Pn I Si 22.50 2.1 57 21 8.615 17.417 16.143 K Factor = 5.60 to 120.0 0.0 8.615 0.0 S2 22.5 0.0048 0.0 26.032 0.126 Vel = 1.98 S2 22.59 2.157 0.0 14.917 16.269 K Factor = 5.60 I to 120.0 0.0 0.0 0.0 S3 45.09 0.0175 0.0 14.917 0.261 Vet = 3.96 S3 22.77 2.157 21 8.615 15.667 16.530 K Factor = 5.60 I to 120.0 0.0 8.615 0.0 S4 67.86 0.0373 0.0 24.282 0.905 Vel = 5.96 S4 23.38 2.157 T 12.307 8.667 17.435 K Factor = 5.60 120.0 0.0 12.307 0.0 I to 300 91.24 0.0644 0.0 20.974 1.351 Vet = 8.01 0.0 91.24 18.786 KFactor= 21.05 I S5 22.97 2.157 0.0 15.000 16.828 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S6 22.97 0.0050 0.0 15.000 0.075 Vet = 2.02 I S6 23.03 2.157 0.0 13.750 16.903 K Factor = 5.60 to 120.0 0.0 0.0 0.0 S7 46.0 0.0181 0.0 13.750 0.249 Vet = 4.04 S7 23.19 2.157 0.0 13.500 17.152 K Factor = 5.60 I to 120.0 0.0 0.0 0.0 S8 69.19 0.0387 0.0 13.500 0.522 Vel = 6.07 S8 23.54 2.157 T 12.307 6.917 17.674 K Factor= 5.60 120.0 0.0 12.307 0.0 I to 301 92.73 0.0664 0.0 19.224 1.276 Vel = 8.14 0.0 92.73 18.950 KFactor= 21.30 I S9 23.62 2.157 0.0 15.000 17.784 K Factor = 5.60 to 120.0 0.0 0.0 0.0 sio 23.62 0.0053 0.0 15.000 0.079 Vel = 2.07 I S10 23.66 2.157 0.0 13.750 17.863 K Factor = 5.60 to 120.0 0.0 0.0 0.0 SII 47.28 0.0191 0.0 13.750 0.263 Vel = 4.15 Si 1 23.85 2.157 0.0 13.500 18.126 K Factor = 5.60 I to 120.0 0.0 0.0 0.0 S12 71.13 0.0406 0.0 13.500 0.548 Vel = 6.25 S12 24.20 2.157 T 12.307 6.917 18.674 K Factor = 5.60 I to 120.0 0.0 12.307 0.0 302 95.33 0.0699 0.0 19.224 1.344 Vel = 8.37 0.0 95.33 20.018 KFactor= 21.31 I 300 91.24 2.635 0.0 6.750 18.786 to 120.0 0.0 0.0 0.0 301 91.24 0.0243 0.0 6.750 0.164 Vel = 5.37 I 301 92.73 2.635 0.0 12.000 18.950 to 120.0 0.0 0.0 0.0 302 183.97 0.0890, 0.0 12.000 1.068 Vel = 10.82 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel (Hotel 3) Exhibition Hall Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C',or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 302 95.32 2.635 T 16.474 27.708 20.018 to 120.0 I 8.237 24.711 0.0 303 279.29 0.1926 0.0 52.419 10.096 Vel = 16.43 I 303 0.0 2.635 I 8.237 21.000 30.114 to 120.0 0.0 8.237 0.0 304 279.29 0.1926 0.0 29.237 5.631 Vel = 16.43 304 0.0 3.26 I 6.72 20.417 35.745 I to 120.0 2T 40.319 47.039 8.662 TR 279.29 0.0683 0.0 67.456 4.608 Vel = 10.74 TR 0.0 3.26 E 9.408 5.750 49.015 I to 120.0 T 20.159 43.007 2.166 BR1 279.29 0.0683 B 13.44 48.757 3.330 Vel = 10.74 BR1 0.0 6.357 J 31.433 5.167 54.511 to 120.0 0.0 31.433 2.238 I SPL 279.29 0.0027 0.0 36.600 0.097 Vel = 2.82 SPL 0.0 6.357 51 62.867 72.667 56.846 to 120.0 0.0 62.867 0.0 I RR1 279.29 0.0026 0.0 135.534 0.358 Vel = 2.82 RR1 0.0 6.357 31 37.72 19.583 57.204 to 120.0 B 12.573 50.293 0.0 RR2 279.29 0.0026 0.0 69.876 0.185 Vel = 2.82 I RR2 0.0 6.357 31 37.72 22.833 57.389 to 120.0 0.0 37.720 0.0 UG1 279.29 0.0026 0.0 60.553 0.160 Vel = 2.82 I UG1 0.0 8.249 F 10.571 248.875 57.549 to 120.0 2E 42.282 52.853 1.227 UG2 279.29 0.0007 0.0 301.728 0.224 Vel = 1.68 UG2 0.0 7.98 G 5.317 75.167 59.000 I to 140.0 0.0 5.317 0.0 FDC 279.29 0.0007 0.0 80.484 0.053 Vel = 1.79 FDC 100.00 7.98 T 46.522 10.208 59.053 Qa = 100 I to 140.0 0.0 46.522 0.0 UG3 379.29 0.0011 0.0 56.730 0.065 Vel = 2.43 UG3 0.0 11.65 3E 95.65 125.167 59.118 140.0 2T 141.704 283.408 0.0 I to UG4 379.29 0.0002 3F 46.054 408.575 0.075 Vel = 1.14 UG4 0.0 11.65 3E 108.672 57.750 59.193 150.0 F 17.441 206.611 1.764 * * Fixed Loss = 4.363 I to TEST 379.29 0.0002 T 80.498 264.361 0.043 Vel = 1.14 Zaf 0.0 0.0 379.29 61.000 K Factor= 48.56 I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name : Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Building Location System Contract Data File : Hotel 3-4th Floor—Deluxe King Room.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - M - M M - - - - - - - Water Supply Curve C Western Fire Protection Inc Page 1 Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Date City Water Supply: Demand: Cl - Static Pressure : 63 Dl - Elevation : 15.592 C2 - Residual Pressure: 22 D2 - System Flow :167.332 C2 - Residual Flow : 8000 D2 - System Pressure : 57.743 Hose ( Demand) :100 D3 - System Demand : 267.332 Safety Margin : 5.180 150 140 130 p120 R11° E 100 590 s 80 U70 -02 R 60 E 50 D3 4 -0 30 - -=ZIIIIIJ C2 20 10 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW (N"1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - M - TEE M - - - - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Date Fitting Legend Abbrev. Name 1/2 % 1 1% 11/2 2 21/2 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I U I U I I I I I I I I I I I I I I I Pressure I Flow Summary - STANDARD Western Fire Protection Inc Page 3 Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Si 38.0 5.6 7.38 na 15.22 0.1 8 7.0 S2 38.0 5.6 7.66 na 15.5 0.1 155 7.0 S3 38.0 5.6 9.06 na 16.86 0.1 151 7.0 S4 38.0 5.6 11.89 na 19.31 0.1 180 7.0 S5 38.0 5.6 14.87 na 21.59 0.1 63 7.0 S6 38.0 5.6 14.96 na 21.66 0.1 108 7.0 S7 38.0 5.6 10.86 na 18.45 0.1 125 7.0 S8 38.0 5.6 10.98 na 18.56 0.1 120 7.0 S9 38.0 5.6 12.99 na 20.18 0.1 150 7.0 39.0 7.74 na 2 39.0 7.86 na 3 39.0 9.36 na 4 39.0 12.41 na 5 39.0 15.15 na 6 39.0 15.7 na 7 39.0 10.99 na 8 39.0 11.46 na 9 39.0 13.69 na 404 39.0 19.14 na 405 39.0 19.28 na 406 39.0 19.42 na 407 39.0 21.96 na TR4 39.0 30.57 na BR413 34.042 37.01 na 408 39.0 35.23 na HV3 47.792 31.55 na H4 47.792 31.73 na HV4 47.792 32.48 na TS2 47.792 32.61 na SPL2 -1.167 53.94 na RR1 -1.167 54.08 na RR2 -1.167 54.15 na UGi -1.167 54.21 na UG2 -4.0 55.53 na FDC -4.0 55.55 na 100.0 UG3 -4.0 55.58 na UG4 -4.0 55.62 na TEST 2.0 57.74 na The maximum velocity is 22.54 and it occurs in the pipe between nodes 4 and 404 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 I Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Date Hyd. Qa Dia. Fitting Pipe Pt Pt - Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn U Si 15.22 1.101 E 3.825 5.958 7.383 K Factor= 5.60 to 150.0 T 9.563 13.387 -0.433 1 15.22 0.0410 0.0 19.345 0.794 Vet = 5.13 0.0 I 15.22 7.744 K Factor = 5.47 S2 15.50 1.101 E 3.825 1.500 7.661 K Factor= 5.60 I to 2 15.5 150.0 0.0425 T 9.563 0.0 13.387 14.887 -0.433 0.632 Vel = 5.22 0.0 15.50 7.860 K Factor = 5.53 I S3 16.86 1.101 E 3.825 1.500 9.060 K Factor = 5.60 to 150.0 T 9.563 13.387 -0.433 3 16.86 0.0496 0.0 14.887 0.738 Vel = 5.68 0.0 I 16.86 9.365 K Factor= 5.51 S4 19.31 1.101 E 3.825 1.500 11.891 K Factor 5.60 to 150.0 T 9.563 13.387 -0.433 I 4 19.31 0.0637 0.0 14.887 0.949 Vel = 6.51 0.0 19.31 12.407 KFactor= 5.48 S5 21.59 1.101 2E 7.65 1.500 14.870 K Factor 5.60 I to 150.0 0.0 7.650 -0.433 5 21.59 0.0784 0.0 9.150 0.717 Vel = 7.28 I 0.0 21.59 15.154 KFactor= 5.55 S6 21.66 1.101 E 3.825 1.500 14.962 K Factor 5.60 to 150.0 T 9.563 13.387 -0.433 6 21.66 0.0789 0.0 14.887 1.174 Vel = 7.30 I 0.0 21.66 15.703 K Factor = 5.47 S7 18.45 1.101 2E 7.65 2.000 10.859 K Factor =5.60 I to 150.0 0.0 7.650 -0.433 7 18.45 0.0587 0.0 9.650 0.566 Vel = 6.22 0.0 I 18.45 10.992 K Factor = 5.56 S8 18.56 1.101 E 3.825 2.000 10.982 K Factor= 5.60 to 150.0 T 9.563 13.387 -0.433 8 18.56 0.0593 0.0 15.387 0.912 Vel = 6.25 I 0.0 18.56 11.461 K Factor = 5.48 I S9 to 20.18 1.101 150.0 E T 3.825 9.563 3.042 13.387 12.988 -0.433 K Factor =5.60 9 20.18 0.0692 0.0 16.429 1.137 Vel = 6.80 0.0 20.18 13.692 K Factor = 5.45 I 1 15.22 1.101 0.0 2.833 7.744 to 150.0 0.0 0.0 0.0 2 15.22 0.0409 0.0 2.833 0.116 Vet = 5.13 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel (Hotel 3)4th Floor - DELUXE KING Date Hyd. Qa Dia. Fitting Pipe Pt Pt - Ref. "C" or Ftngs Fe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 2 15.50 1.101 0.0 10.000 7.860 to 150.0 0.0 0.0 0.0 3 30.72 0.1505 0.0 10.000 1.505 Vel 10.35 I 16.85 1.101 0.0 9.000 9.365 to 150.0 0.0 0.0 0.0 4 47.57 0.3380 0.0 9.000 3.042 Vel = 16.03 4 19.31 1.101 T 9.563 1.042 12.407 I to 150.0 0.0 9.562 0.0 404 66.88 0.6349 0.0 10.604 6.733 Vel = 22.54 0.0 I 66.88 19.140 K Factor = 15.29 5 21.59 1.101 0.0 7.000 15.154 to 150.0 0.0 0.0 0.0 6 21.59 0.0784 0.0 7.000 0.549 Vel = 7.28 I 6 21.67 1.101 T 9.563 3.042 15.703 to 150.0 0.0 9.562 0.0 405 43.26 0.2835 0.0 12.604 3.573 Vet = 14.58 I 0.0 43.26 19.276 K Factor= 9.85 7 18.45 1.101 0.0 8.000 10.992 150.0 0.0 0.0 0.0 I to 8 18.45 0.0586 0.0 8.000 0.469 Vet = 6.22 8 18.56 1.101 0.0 10.500 11.461 I to 9 37.01 150.0 0.2125 0.0 0.0 0.0 10.500 0.0 2.231 Vel = 12.47 9 20.18 1.101 T 9.563 2.500 13.692 to 150.0 0.0 9.562 0.0 406 57.19 0.4753 0.0 12.062 5.733 Vel = 19.27 I 0.0 57.19 19.425 K Factor = 12.98 404 66.88 2.635 0.0 10.000 19.140 I to 120.0 0.0 0.0 0.0 405 66.88 0.0136 0.0 10.000 0.136 Vel = 3.93 405 43.26 2.635 0.0 6.500 19.276 I to 150.0 0.0 0.0 0.0 406 110.14 0.0229 0.0 6.500 0.149 Vel = 6.48 406 57.19 2.635 E 12.447 38.833 19.425 150.0 0.0 12.446 0.0 I to 407 167.33 0.0494 0.0 51.279 2.533 Vet = 9.84 407 0.0 2.635 41 49.787 74.667 21.958 to 150.0 2T 49.787 99.576 0.0 TR4 167.33 0.0494 0.0 174.243 8.609 Vel = 9.84 I TR4 0.0 2.635 E 12.447 6.000 30.567 to 150.0 T 24.894 80.904 2.147 BR413 167.33 0.0494 B 14.521 86.904 4.294 Vel = 9.84 I S 29.043 BR413 0.0 4.26 21 18.434 32.542 37.008 to 120.0 0.0 18.434 -2.147 408 167.33 0.0072 0.0 50.976 0.366 Vel = 3.77 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 6 Westin Hotel (Hotel 3) 4th Floor - DELUXE KING Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 408 0.0 4.26 I 9.217 8.792 35.227 to 120.0 0.0 9.217 -3.808 HV3 167.33 0.0072 0.0 18.009 0.130 Vel = 3.77 HV3 0.0 4.26 J 21.067 4.250 31.549 I to 120.0 0.0 21.067 0.0 H4 167.33 0.0072 0.0 25.317 0.182 Vel = 3.77 H4 0.0 4.26 I 9.217 73.833 31.731 I to 120.0 J 21.067 30.284 0.0 HV4 167.33 0.0072 0.0 104.117 0.749 VeI= 3.77 HV4 0.0 4.26 I 9.217 8.208 32.480 120.0 0.0 9.217 0.0 I to TS2 167.33 0.0072 0.0 17.425 0.126 Vel = 3.77 TS2 0.0 6.357 31 37.72 58.125 32.606 120.0 J 31.433 69.153 21.204 I to SPL2 167.33 0.0010 0.0 127.278 0.130 Vel = 1.69 SPL2 0.0 6.357 51 62.867 72.667 53.940 to 120.0 0.0 62.867 0.0 RR1 167.33 0.0010 0.0 135.534 0.139 Vel = 1.69 U RR1 0.0 6.357 31 37.72 19.583 54.079 to 120.0 B 12.573 50.293 0.0 RR2 167.33 0.0010 0.0 69.876 0.072 Vel = 1.69 I RR2 0.0 6.357 31 37.72 22.833 54.151 to 120.0 0.0 37.720 0.0 UGI 167.33 0.0010 0.0 60.553 0.062 Vel = 1.69 I UG1 0.0 8.249 F 10.571 248.875 54.213 to 120.0 2E 42.282 52.853 1.227 UG2 167.33 0.0003 0.0 301.728 0.087 Vel = 1.00 UG2 0.0 7.98 G 5.317 75.167 55.527 I to 140.0 0.0 5.317 0.0 FDC 167.33 0.0002 0.0 80.484 0.020 Vel = 1.07 FDC 100.00 7.98 T 46.522 10.208 55.547 Qa = 100 I to 140.0 0.0 46.522 0.0 UG3 267.33 0.0006 0.0 56.730 0.035 Vel = 1.71 UG3 0.0 11.65 3E 95.65 125.167 55.582 140.0 2T 141.704 283.408 0.0 I to UG4 267.33 0.0001 3F 46.054 408.575 0.039 Vel = 0.80 UG4 0.0 11.65 3E 108.672 57.750 55.621 to 150.0 F 17.441 206.611 2.100 **Fixed Loss 4.699 I TEST 267.33 0.0001 T 80.498 264.361 0.022 Vel = 0.80 Zaf 0.0 0.0 267.33 57.743 KFactor= 35.18 I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I H I Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name : Westin Hotel (Hotel 3) 4th Floor - Housekeeping Building Location System Contract Data File : Hotel 34th Floor_Housekeeping.WXF I I I H I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - _ - - - - - - - - - Water Supply Curve C Western Fire Protection Inc Page 1 Westin Hotel (Hotel 3) 4th Floor - Housekeeping Date City Water Supply: Demand: Cl - Static Pressure : 63 Dl - Elevation : 15.592 C2 - Residual Pressure: 22 D2 - System Flow : 199.058 C2 - Residual Flow : 8000 D2 - System Pressure : 60.486 Hose ( Demand ) : 250 D3 - System Demand : 449.058 Safety Margin : 2.315 150 140 130 120 R11° E10° S90 s 8° u 7° R 60 E 50 D3-- 40 30 - C2 20 DI 10 .I I I I . 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - = M - - - - - - M - - - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) 4th Floor - Housekeeping Date Fitting Legend Abbrev. Name 1/2 11/4 1% 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90'Grvd-Vic Elbow #lO 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Fire Protection Inc Westin Hotel (Hotel 3) 4th Floor - Housekeeping Node Elevation K-Fact Pt Pn Flow No. Actual Actual Si 38.0 5.6 12.13 na 19.5 S2 38.0 5.6 12.93 na 20.14 I S3 S4 38.0 38.0 5.6 5.6 16.35 15.15 na na 22.64 21.8 S5 38.0 5.6 16.0 na 22.4 S6 38.0 5.6 17.71 na 23.57 S7 38.0 5.6 19.02 na 24.42 S8 38.0 5.6 15.42 na 21.99 I S9 38.0 5.6 16.29 na 22.6 1 39.0 12.87 na 2 39.0 13.62 na 3 39.0 17.31 na I 4 39.0 16.02 na 5 39.0 16.93 na 6 39.0 18.77 na 39.0 20.18 na 8 39.0 16.31 na I 9 39.0 17.24 na 450 39.0 23.69 na 451 39.0 23.7 na 452 39.0 24.12 na I TR4 39.0 31.29 na BR413 34.042 39.36 na 408 39.0 37.72 na I HV3 H4 47.792 47.792 34.09 34.34 na na HV4 47.792 35.37 na TS2 47.792 35.55 na SPL2 -1.167 56.93 na I RR1 -1.167 57.12 na RR2 -1.167 57.22 na UG1 -1.167 57.31 na UG2 -4.0 58.65 na FDC -4.0 58.68 na 250.0 I UG3 -4.0 58.77 na UG4 -4.0 58.87 na TEST 2.0 60.49 na I The maximum velocity is 23.12 and it occurs in the pipe between nodes 3 and 450 I I I I I Page 3 Date Density Area Press 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 0.15 130 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel (Hotel 3) 4th Floor - Housekeeping Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I Si 19.50 1.049 E 2.0 2.500 12.125 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 1 19.5 0.1242 0.0 9.500 1.180 VeI= 7.24 0.0 I 19.50 12.872 K Factor= 5.44 S2 20.14 1.049 E 2.0 1.500 12.930 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 I 2 20.14 0.1318 0.0 8.500 1.120 Vel 7.48 0.0 20.14 13.617 K Factor = 5.46 S3 22.64 1.049 E 2.0 1.500 16.349 K Factor = 5.60 I to 120.0 T 5.0 7.000 -0.433 3 22.64 0.1636 0.0 8.500 1.391 Vel = 8.40 0.0 I 22.64 17.307 K Factor = 5.44 S4 21.80 1.049 E 2.0 1.500 15.153 K Factor = 5.60 to 120.0 T 5.0 7.000 -0.433 4 21.8 0.1526 0.0 8.500 1.297 Vel = 8.09 I 0.0 21.80 16.017 K Factor = 5.45 S5 22.40 1.049 E 2.0 1.500 16.002 K Factor 5.60 I to 120.0 T 5.0 7.000 -0.433 5 22.4 0.1605 0.0 8.500 1.364 Vel = 8.32 0.0 I 22.40 16.933 K Factor = 5.44 S6 23.57 1.049 E 2.0 1.500 17.708 K Factor = 5.60 to 120.0 T 5.0 7.000 -0.433 6 23.57 0.1762 0.0 8.500 1.498 Vel = 8.75 .I 0.0 23.57 18.773 K Factor= 5.44 S7 24.42 1.049 E 2.0 1.500 19.016 K Factor= 5.60 I to 120.0 T 5.0 7.000 -0.433 7 24.42 0.1882 0.0 8.500 1.600 Vel = 9.07 0.0 24.42 20.183 K Factor = 5.44 I S8 21.99 1.049 E 2.0 1.500 15.425 K Factor = 5.60 to 120.0 T 5.0 7.000 -0.433 8 21.99 0.1551 0.0 8.500 1.318 Vel = 8.16 I 0.0 21.99 16.310 KFactor= 5.45 S9 22.60 1.049 E 2.0 1.500 16.287 K Factor= 5.60 I to 120.0 T 5.0 7.000 -0.433 9 22.6 0.1632 0.0 8.500 1.387 Vel = 8.39 0.0 22.60 17.241 K Factor = 5.44 I 1 19.50 1.049 0.0 6.000 12.872 to 120.0 0.0 0.0 0.0 2 19.5 0.1242 0.0 6.000 0.745 Vel = 7.24 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 u Westin Hotel (Hotel 3) 4th Floor - Housekeeping Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. I.G. or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 2 20.14 1.049 0.0 8.000 13.617 to 120.0 0.0 0.0 0.0 3 39.64 0.4612 0.0 8.000 3.690 Vel = 14.72 3 22.64 1.049 T 5.0 1.000 17.307 I to 120.0 0.0 5.000 0.0 450 62.28 1.0642 0.0 6.000 6.385 Vet = 23.12 0.0 I 62.28 23.692 K Factor= 12.80 4 21.80 1.049 0.0 6.000 16.017 to 120.0 0.0 0.0 0.0 S21.8 0.1527 0.0 6.000 0.916 Vel = 8.09 I 5 22.40 1.049 T 5.0 7.000 16.933 to 120.0 0.0 5.000 0.0 451 44.2 0.5642 0.0 12.000 6.771 Vel = 16.41 I 0.0 44.20 23.704 K Factor= 9.08 6 23.57 1.049 0.0 8.000 18.773 I to 120.0 0.0 0.0 0.0 7 23.57 0.1762 0.0 8.000 1.410 Vet = 8.75 7 24.42 1.049 T 5.0 1.000 20.183 120.0 0.0 5.000 0.0 I to 452 47.99 0.6570 0.0 6.000 3.942 Vet = 17.82 0.0 47.99 24.125 K Factor = 9.77 I 8 21.99 1.049 0.0 6.000 16.310 to 120.0 0.0 0.0 0.0 9 21.99 0.1552 0.0 6.000 0.931 Vel = 8.16 9 22.60 1.049 T 5.0 7.000 17.241 I to 120.0 0.0 5.000 0.0 452 44.59 0.5737 0.0 12.000 6.884 Vel = 16.55 I 0.0 44.59 24.125 K Factor= 9.08 450 62.28 2.635 0.0 1.000 23.692 to 120.0 0.0 0.0 0.0 451 62.28 0.0120 0.0 1.000 0.012 Vel = 3.66 I 451 44.20 2.635 0.0 13.000 23.704 to 120.0 0.0 0.0 0.0 452 106.48 0.0324 0.0 13.000 0.421 Vet = 6.26 I 452 92.58 2.635 31 37.34 43.000 24.125 to 150.0 T 24.894 62.234 0.0 TR4 199.06 0.0681 0.0 105.234 7.168 Vel = 11.71 I TR4 0.0 2.635 E 12.447 6.000 31.293 to 150.0 T 24.894 80.904 2.147 BR413 199.06 0.0681 B 14.521 86.904 5.921 Vel = 11.71 29.043 BR413 I s 0.0 4.26 21 18.434 32.542 39.361 to 120.0 0.0 18.434 -2.147 408 199.06 0.0099 0.0 50.976 0.505 Vet = 4.48 I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 6 Westin Hotel (Hotel 3) 4th Floor - Housekeeping Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C'.or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 408 0.0 4.26 I 9.217 8.792 37.719 to 120.0 0.0 9.217 -3.808 HV3 199.06 0.0099 0.0 18.009 0.179 Vel = 4.48 HV3 0.0 4.26 J 21.067 4.250 34.090 I to 120.0 0.0 21.067 0.0 H4 199.06 0.0099 0.0 25.317 0.251 Vel = 4.48 H4 0.0 4.26 I 9.217 73.833 34.341 I to 120.0 J 21.067 30.284 0.0 HV4 199.06 0.0099 0.0 104.117 1.033 Vel = 4.48 HV4 0.0 4.26 I 9.217 8.208 35.374 120.0 0.0 9.217 0.0 I to TS2 199.06 0.0099 0.0 17.425 0.173 Vel = 4.48 TS2 0.0 6.357 31 37.72 58.125 35.547 120.0 J 31.433 69.153 21.204 I to SPL2 199.06 0.0014 0.0 127.278 0.180 Vel = 2.01 SPL2 0.0 6.357 51 62.867 72.667 56.931 to 120.0 0.0 62.867 0.0 RR1 199.06 0.0014 0.0 135.534 0.191 Vel = 2.01 I RRI 0.0 6.357 31 37.72 19.583 57.122 to 120.0 B 12.573 50.293 0.0 RR2 199.06 0.0014 0.0 69.876 0.099 Vel = 2.01 I RR2 0.0 6.357 31 37.72 22.833 57.221 to 120.0 0.0 37.720 0.0 UG1 199.06 0.0014 0.0 60.553 0.085 Vel = 2.01 I UG1 0.0 8.249 F 10.571 248.875 57.306 to 120.0 2E 42.282 52.853 1.227 UG2 199.06 0.0004 0.0 301.728 0.120 Vel = 1.20 UG2 0.0 7.98 G 5.317 75.167 58.653 I to 140.0 0.0 5.317 0.0 FDC 199.06 0.0003 0.0 80.484 0.028 Vel = 1.28 FDC 250.00 7.98 T 46.522 10.208 58.681 Qa = 250 I to 140.0 0.0 46.522 0.0 UG3 449.06 0.0016 0.0 56.730 0.090 Vel = 2.88 UG3 0.0 11.65 3E 95.65 125.167 58.771 to 140.0 2T 141.704 283.408 0.0 I UG4 449.06 0.0002 3F 46.054 408.575 0.102 Vel = 1.35 UG4 0.0 11.65 3E 108.672 57.750 58.873 to 150.0 F 17.441 206.611 1.554 * * Fixed Loss = 4.153 I TEST 449.06 0.0002 T 80.498 264.361 0.059 Vel 1.35 Zaf 0.0 0.0 449.06 60.486 K Factor= 57.74 I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name : Westin Hotel (Hotel 3) 4th Floor Building Location System Contract Data File : Hotel 3-4th Floor—King Room.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I I I I I I I I I I I - - - - - = - - - - - - - Water Supply Curve C Western Fire Protection Inc Page 1 Westin Hotel (Hotel 3) 4th Floor Date City Water Supply: Demand: Cl - Static Pressure : 63 Dl - Elevation : 15.592 C2 - Residual Pressure: 22 D2 - System Flow : 116.683 C2 - Residual Flow : 8000 D2 - System Pressure : 57.758 Hose ( Demand) :100 D3 - System Demand : 216.683 Safety Margin : 5.190 150 140 130 p120 R11° E 100 s 9° s 8° u 7° T :Z R6° E 50 D3 40 - - 30 - - C2 :DI 10002000 3000 4000 5000 6000 7000 8000 9000 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - - - - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) 4th Floor Date Fitting Legend Abbrev. Name 1/2 % 1 11/4 1V2 2 2h/ 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139OStandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90'Grvd-Vic Elbow #lO 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90Tee-BranchGry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I I I I I I I I I I I I I I I I I I Pressure I Flow Summary - STANDARD Western Fire Protection Inc Page 3 Westin Hotel (Hotel 3) 4th Floor Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Si 38.0 5.6 12.65 na 19.92 0.1 8 7.0 S2A 38.0 5.6 12.76 na 20.0 0.1 200 7.0 S213 38.0 5.6 14.71 na 21.48 0.1 150 7.0 S3 38.0 5.6 23.66 na 27.24 0.1 15 7.0 S4 38.0 5.6 25.08 na 28.04 0.1 144 7.0 39.0 12.55 na A 39.0 13.9 na B 39.0 16.08 na 3 39.0 25.02 na 400 39.0 26.52 na 401 39.0 26.57 na 403 39.0 26.59 na 404 39.0 27.29 na 405 39.0 27.67 na 406 39.0 27.84 na 407 39.0 29.14 na TR4 39.0 33.56 na BR413 34.042 37.91 na 408 39.0 35.95 na HV3 47.792 32.21 na H4 47.792 32.3 na HV4 47.792 32.69 na TS2 47.792 32.75 na SPL2 -1.167 54.02 na RR1 -1.167 54.09 na RR2 -1.167 54.13 na UG1 -1.167 54.16 na UG2 -4.0 55.43 na FDC -4.0 55.44 na 100.0 UG3 -4.0 55.47 na UG4 -4.0 55.49 na TEST 2.0 57.76 na The maximum velocity is 20.69 and it occurs in the pipe between nodes B and 400 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel (Hotel 3) 4th Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C'.or Ftng's Pe Pv ******* Notes Point Qt P1/Ft Eqv. Ln. Total P1 Pn I Si 19.92 1.101 E 3.825 1.000 12.653 K Factor = 5.60 to 150.0 0.0 3.825 -0.433 1 19.92 0.0676 0.0 4.825 0.326 Vel = 6.71 0.0 19.92 19.92 12.546 KFactor = 5.62 S2A 20.00 1.101 2E 7.65 6.000 . 12.755 K Factor = 5.60 150.0 T 9.563 17.212 -0.433 I to A 20.0 0.0680 0.0 23.212 1.579 Vel = 6.74 0.0 20.00 13.901 K Factor = 5.36 1 S213 21.48 1.101 2E 7.65 6.000 14.711 KFactor = 5.60 to 150.0 T 9.563 17.212 -0.433 B 21.48 0.0776 0.0 23.212 1.802 Vel = 7.24 0.0 I 21.48 16.080 K Factor = 5.36 S3 27.24 1.101 E 3.825 1.500 23.661 K Factor = 5.60 to 150.0 T 9.563 13.387 -0.433 I3 27.24 0.1204 0.0 14.887 1.793 Vel = 9.18 0.0 27.24 25.021 K Factor = 5.45 S4 28.04 1.101 E 3.825 1.875 25.080 K Factor = 5.60 I to 150.0 T 9.563 13.387 -0.433 403 28.04 0.1272 0.0 15.262 1.941 Vel = 9.45 P 0.0 28.04 26.588 K Factor = 5.44 1 19.92 1.101 E 3.825 16.250 12.546 to 150.0 0.0 3.825 0.0 19.92 0.0675 0.0 20.075 1.355 Vel = 6.71 I A A 20.00 1.101 0.0 8.917 13.901 to 150.0 0.0 0.0 0.0 39.92 0.2444 0.0 8.917 2.179 Vel = 13.45 P B B 21.48 1.101 T 9.563 9.708 16.080 to 150.0 0.0 9.562 0.0 400 61.4 0.5420 0.0 19.270 10.444 Vel = 20.69 P 0.0 61.40 26.524 K Factor= 11.92 3 27.24 1.101 T 9.563 3.292 25.021 150.0 0.0 9.562 0.0 I to 401 27.24 0.1205 0.0 12.854 1.549 Vel = 9.18 0.0 27.24 26.570 K Factor 5.28 P 400 61.40 2.635 0.0 6.000 26.524 to 150.0 0.0 0.0 0.0 401 61.4 0.0077 0.0 6.000 0.046 Vel = 3.61 401 27.24 2.635 0.0 1.167 26.570 P to 150.0 0.0 0.0 0.0 403 88.64 0.0154 0.0 1.167 0.018 Vel = 5.22 403 28.04 2.635 0.0 27.667 26.588 I to 150.0 0.0 0.0 0.0 404 116.68 0.0254 0.0 27.667 0.702 Vel = 6.86 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel (Hotel 3) 4th Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I 404 0.0 2.635 0.0 10.000 27.290 to 120.0 0.0 0.0 0.0 405 116.68 0.0383 0.0 10.000 0.383 Vel = 6.86 405 0.0 2.635 0.0 6.500 27.673 I to 150.0 0.0 0.0 0.0 406 116.68 0.0254 0.0 6.500 0.165 Vel = 6.86 406 0.0 2.635 E 12.447 38.833 27.838 I to 150.0 0.0 12.446 0.0 407 116.68 0.0254 0.0 51.279 1.300 Vel = 6.86 407 0.0 2.635 41 49.787 74.667 29.138 I to 150.0 2T 49.787 99.576 0.0 TR4 116.68 0.0254 0.0 174.243 4.419 Vel = 6.86 TR4 0.0 2.635 E 12.447 6.000 33.557 to 150.0 T 24.894 80.904 2.147 I BR413 116.68 0.0254 B 14.521 86.904 2.204 Vel = 6.86 S 29.043 BR413 0.0 4.26 21 18.434 32.542 37.908 120.0 0.0 18.434 -2.147 I to 408 116.68 0.0037 0.0 50.976 0.188 Vel = 2.63 408 0.0 4.26 I 9.217 8.792 35.949 120.0 0.0 9.217 -3.808 I to HV3 116.68 0.0037 0.0 18.009 0.067 Vel = 2.63 HV3 0.0 4.26 J 21.067 4.250 32.208 to 120.0 0.0 21.067 0.0 H4 116.68 0.0037 0.0 25.317 . 0.093 Vel = 2.63 I H4 0.0 4.26 I 9.217 73.833 32.301 to 120.0 J 21.067 30.284 0.0 HV4 116.68 0.0037 0.0 104.117 0.384 Vel = 2.63 I HV4 0.0 4.26 I 9.217 8.208 32.685 to 120.0 0.0 9.217 0.0 TS2 116.68 0.0037 0.0 17.425 0.065 Vel = 2.63 I TS2 0.0 6.357 31 37.72 58.125 32.750 to 120.0 J 31.433 69.153 21.204 SPL2 116.68 0.0005 0.0 127.278 0.067 Vel = 1.18 SPL2 0.0 6.357 51 62.867 72.667 54.021 I to 120.0 0.0 62.867 0.0 RRI 116.68 0.0005 0.0 135.534 0.071 Vel = 1.18 RR1 0.0 6.357 31 37.72 19.583 54.092 I to 120.0 B 12.573 50.293 0.0 RR2 116.68 0.0005 0.0 69.876 0.037 Vel= 1.18 RR2 0.0 6.357 31 37.72 22.833 54.129 to 120.0 0.0 37.720 0.0 I UG1 116.68 0.0005 0.0 60.553 0.032 Vel = 1.18 UG1 0.0 8.249 F 10.571 248.875 54.161 120.0 2E 42.282 52.853 1.227 I to UG2 116.68 0.0001 0.0 301.728 0.044 Vel = 0.70 UG2 0.0 7.98 G 5.317 75.167 55.432 to 140.0 0.0 5.317 0.0 FDC 116.68 0.0001 0.0 80.484 0.011 Vel = 0.75 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 6 Westin Hotel (Hotel 3) 4th Floor Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I FDC 100.00 7.98 T 46.522 10.208 55.443 Qa = 100 to 140.0 0.0 46.522 0.0 UG3 216.68 0.0004 0.0 56.730 0.023 Vel = 1.39 I UG3 0.0 11.65 3E 95.65 125.167 55.466 to 140.0 2T 141.704 283.408 0.0 UG4 216.68 0.0001 3F 46.054 408.575 0.027 Vel = 0.65 UG4 0.0 11.65 3E 108.672 57.750 55.493 P to 150.0 F 17.441 206.611 2.250 * * Fixed Loss = 4.849 TEST 216.68 0.0001 T 80.498 264.361 0.015 Vel = 0.65 Zaf 0.0 I 0.0 216.68 57.758 K Factor = 28.51 I I I I I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I I [1 I I I I I I I I I Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 I I I I Job Name : Westin Hotel (Hotel 3) High Roof Building Location System Contract Data File : Hotel 3_High Roof.WXF I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 City Water Supply: Cl - Static Pressure : 63 C2 - Residual Pressure: 22 C2 - Residual Flow : 8000 Demand: Dl - Elevation : 19.850 D2 - System Flow :158.004 D2 - System Pressure : 52.179 Hose ( Demand) :100 D3 - System Demand : 258.004 Safety Margin : 10.750 - - - - - - - M - - - Water Supply Curve C Western Fire Protection Inc Page 1 Westin Hotel (Hotel 3) High Roof Date 150 140 130 p120 R° E10° 590 s 8° U70 R 60 D2 E 50 - 40D3 30 - - C2 20 10 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - _ = - M M - - M M - M M - M - •— Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel (Hotel 3) High Roof Date Fitting Legend Abbrev. Name % % 1 1'/4 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90'Grvd-Vic Elbow #lO 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Fire Protection Inc Westin Hotel (Hotel 3) High Roof Node Elevation K-Fact Pt Pn Flow No. Actual Actual I Si 47.833 5.6 16.38 na 22.67 S2 47.833 5.6 16.23 na 22.56 S3 47.833 5.6 16.14 na 22.5 I S4 47.833 5.6 16.14 na 22.5 S5 47.833 5.6 16.17 na 22.52 S6 47.833 5.6 16.21 na 22.54 S7 47.833 5.6 16.45 na 22.71 55 47.833 22.36 na I 50 47.833 20.88 na 51 39.833 26.11 na 53 39.833 26.28 na TRS 39.833 26.75 na I 54 46.167 24.04 na BR5 43.333 29.01 na BR4 34.042 33.08 na I SPL RR1 -1.167 -1.167 48.39 48.52 na na RR2 -1.167 48.58 na UG1 -1.167 48.64 na UG2 -4.0 49.94 na FDC -4.0 49.96 na 100.0 I UG3 -4.0 49.99 na UG4 -4.0 50.03 na TEST 2.0 52.18 na I I The maximum velocity is 8.83 and it occurs in the pipe between nodes 54 and BR5 I I I I I I I I Page 3 Date Density Area Press 0.1 225 7.0 0.1 225 7.0 0.1 225 7.0 0.1 225 7.0 0.1 225 7.0 0.1 225 7.0 0.1 225 7.0 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 I Westin Hotel (Hotel 3) High Roof Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I Si -50.23 2.703 I 9.325 12.500 16.383 K Factor = 5.60 to 120.0 0.0 9.325 0.0 S2 -50.23 -0.0071 0.0 21.825 -0.156 Vet = 2.81 S2 22.55 2.703 31 27.976 7.292 16.227 K Factor =5.60 I to 120.0 0.0 27.976 0.0 S3 -27.68 -0.0024 0.0 35.268 -0.083 Vel = 1.55 I S3 to 22.51 2.703 120.0 0.0 0.0 8.000 0.0 1 6.144 0.0 K Factor 5.60 S4 -5.17 -0.0001 0.0 8.000 -0.001 Vel = 0.29 S4 22.50 2.703 21 18.651 9.000 16.143 K Factor = 5.60 120.0 0.0 18.651 0.0 I to S5 17.33 0.0010 0.0 27.651 0.028 Vel = 0.97 S5 22.51 2.703 0.0 8.000 16.171 K Factor = 5.60 I to S6 39.84 120.0 0.0046 0.0 0.0 0.0 8.000 0.0 0.037 Vet = 2.23 S6 22.55 2.703 21 18.651 4.417 16.208 K Factor = 5.60 to 120.0 0.0 18.651 0.0 S7 62.39 0.0106 0.0 23.068 0.245 Vet = 3.49 I S7 22.71 2.703 81 74.603 219.500 16.453 - K Factor 5.60 to 120.0 T 18.651 93.254 0.0 55 85.1 0.0189 0.0 312.754 5.904 Vet = 4.76 I 55 0.0 2.703 31 27.976 21.167 22.357 to 120.0 0.0 27.976 3.465 TR5 85.1 0.0189 0.0 49.143 0.928 Vet = 4.76 I 0.0 85.10 26.750 KFactor= 16.45 Si 72.90 2.703 III 102.579 214.833 16.383 120.0 0.0 102.579 0.0 I to 50 72.9 0.0142 0.0 317.412 4.500 Vet = 4.08 50 0.0 2.703 31 27.976 77.833 20.883 to 120.0 T 18.651 46.627 3.465 51 72.9 0.0142 0.0 124.460 1.764 Vet = 4.08 I 51 0.0 2.703 I 9.325 2.542 26.112 to 120.0 0.0 9.325 0.0 53 72.9 0.0142 0.0 11.867 0.169 Vet = 4.08 I 53 0.0 2.703 I 9.325 7.792 26.281 to 120.0 T 18.651 27.976 -2.743 54 72.9 0.0141 0.0 35.768 0.506 Vet = 4.08 I 0.0 72.90 24.044 K Factor = 14.87 TR5 85.10 2.703 0.0 2.000 26.750 120.0 0.0 0.0 -2.743 I to 54 85.1 0.0185 0.0 2.000 0.037 Vet = 4.76 54 72.90 2.703 E 9.325 2.500 24.044 120.0 T 18.651 60.615 1.227 I to BR5 158.0 0.0593 B 10.88 63.115 3.744 Vet = 8.83 S 21.759 BR5 0.0 6.357 21 25.147 16.250 29.015 to 120.0 0.0 25.147 4.024 I BR4 158.0 0.0009 0.0 41.397 0.038 Vet = 1.60 I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel (Hotel 3) High Roof Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I BR4 0.0 6.357 T 37.72 35.208 33.077 to 120.0 0.0 37.720 15.249 SPL 158.0 0.0009 0.0 72.928 0.067 Vel = 1.60 I SPL 0.0 6.357 51 62.867 72.667 48.393 to 120.0 0.0 62.867 0.0 RR1 158.0 0.0009 0.0 135.534 0.125 Vet = 1.60 RR1 0.0 6.357 31 37.72 19.583 48.518 I to 120.0 B 12.573 50.293 0.0 RR2 158.0 0.0009 0.0 69.876 0.064 Vel = 1.60 RR2 0.0 6.357 31 37.72 22.833 48.582 I to 120.0 0.0 37.720 0.0 UG1 158.0 0.0009 0.0 60.553 0.056 Vel = 1.60 UG1 0.0 8.249 F 10.571 248.875 48.638 to 120.0 2E 42.282 52.853 1.227 I UG2 158.0 0.0003 0.0 301.728 0.078 Vel = 0.95 UG2 0.0 7.98 G 5.317 75.167 49.943 to 140.0 0.0 5.317 0.0 I FDC 158.0 0.0002 0.0 80.484 0.019 Vel = 1.01 FDC 100.00 7.98 T 46.522 10.208 49.962 Qa = 100 to 140.0 0.0 46.522 0.0 UG3 258.0 0.0006 0.0 56.730 0.032 Vet = 1.66 I UG3 0.0 11.65 3E 95.65 125.167 49.994 to 140.0 2T 141.704 283.408 0.0 UG4 258.0 0.0001 3F 46.054 408.575 0.037 Vet = 0.78 I UG4 0.0 11.65 3E 108.672 57.750 50.031 to 150.0 F 17.441 206.611 2.127 **Fixed Loss 4.726 TEST 258.0 0.0001 T 80.498 264.361 0.021 Vet = 0.78 Zaf 0.0 I 0.0 258.00 52.179 KFactor= 35.72 I I I I 1 I IComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Western Fire Protection Inc 13630 Danielson St Lic # C16-588039 Poway, CA 92064 858-513-4949 Job Name Westin Hotel - Hose Valve Building Location System Contract Data File : Hose Valve.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - - - - 1=11 M =11 - - M _ - _ _ _ Water Supply Curve C Western Fire Protection Inc Page Westin Hotel - Hose Valve Date City Water Supply: Demand: Cl - Static Pressure : 151 Dl - Elevation : 22.431 C2 - Residual Pressure: 150 D2 - System Flow C2 - Residual Flow : 1000 D2 - System Pressure : 139.791 Hose ( Demand) :1000 D3 - System Demand :1000 Safety Margin : 10.209 180 168 156 p144 R132 - D3 E120 5108 s 96 u84 R72 E6° 48 36 24 - ....I ......... 12 I.I.I.... I ... .......... .. I 100 200 300 400 500 600 700 800 900 FLOW( N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 - - - - - M - - - - M - Fittings Used Summary Western Fire Protection Inc Page 2 Westin Hotel - Hose Valve Date Fitting Legend Abbrev. Name % % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90'Grvd-Vic Elbow #lO 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Western Fire Protection Inc Westin Hotel - Hose Valve Node No. Elevation K-Fact Pt Actual Pn Flow Actual HV1 3.667 88.03 na 250.0 HV2 13.667 83.85 na 250.0 HI H2 3.0 13.667 92.3 87.83 na na H3 47.792 75.45 na HV3 47.792 87.6 na 250.0 H4 47.792 87.98 na HV4 47.792 100.0 na 250.0 TS2 47.792 103.42 na SPL2 -1.167 128.19 na RR1 -1.167 131.98 na RR2 -1.167 133.94 na UG1 -1.167 135.63 na UG2 -4.0 139.23 na FDC -4.0 139.79 na UG3 -4.0 139.79 na UG4 -4.0 139.79 na TEST 2.0 142.69 na Page 3 Date Density Area Press I The maximum velocity is 22.51 and it occurs in the pipe between nodes HV4 and TS2 I I I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 4 Westin Hotel - Hose Valve Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftngs Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I HV1 250.00 2.469 E 6.0 0.500 88.029 Qa = 250 to 120.0 T 12.0 18.000 0.289 Hi 250.0 0.2154 0.0 18.500 3.985 Vel = 16.75 0.0 I 250.00 92.303 K Factor= 26.02 HV2 250.00 2.469 E 6.0 0.500 83.850 Qa = 250 120.0 T 12.0 18.000 0.0 I to H2 250.0 0.2154 0.0 18.500 3.985 Vel = 16.75 0.0 250.00 87.835 K Factor= 26.68 Hi 250.00 4.26 0.0 10.000 92.303 I to 120.0 0.0 0.0 -4.620 H2 250.0 0.0152 0.0 10.000 0.152 Vel = 5.63 H2 250.00 4.26 I 9.217 34.792 87.835 to I 120.0 0.0 9.217 -14.780 H3 500.0 0.0545 0.0 44.009 2.399 Vel = 11.25 H3 0.0 4.26 41 36.868 171.875 75.454 120.0 J 21.067 57.935 0.0 I to H4 500.0 0.0545 0.0 229.810 12.528 Vel = 11.25 0.0 500.00 87.982 K Factor = 53.31 HV3 I 250.00 4.26 J 21.067 4.250 87.600 Qa = 250 to 120.0 0.0 21.067 0.0 H4 250.0 0.0151 0.0 25.317 0.382 Vel = 5.63 I H4 500.00 4.26 I 9.217 73.833 87.982 to - 120.0 J 21.067 30.284 0.0 HV4 750.0 0.1154 0.0 104.117 12.018 Vel = 16.88 HV4 250.00 4.26 I 9.217 8.208 100.000 Qa = 250 to U 120.0 0.0 9.217 0.0 TS2 1000.0 0.1966 0.0 17.425 3.425 Vel = 22.51 TS2 0.0 6.357 31 37.72 58.125 103.425 I to 120.0 J 31.433 69.153 21.204 SPL2 1000.0 0.0280 0.0 127.278 3.561 Vel = 10.11 SPL2 0.0 6.357 51 62.867 72.667 128.190 120.0 0.0 62.867 0.0 I to RRi 1000.0 0.0280 0.0 135.534 3.792 Vel = 10.11 RR1 0.0 6.357 31 37.72 19.583 131.982 120.0 B 12.573 50.293 0.0 I to RR2 1000.0 0.0280 0.0 69.876 1.955 Vel 10.11 RR2 0.0 6.357 31 37.72 22.833 133.937 to 120.0 0.0 37.720 0.0 UG1 1000.0 0.0280 0.0 60.553 1.694 Vel = 10.11 I UG1 0.0 8.249 F 10.571 248.875 135.631 to 120.0 2E 42.282 52.853 1.227 UG2 1000.0 0.0079 0.0 301,728 2.373 Vel = 6.00 UG2 I 0.0 7.98 G 5.317 75.167 139.231 to 140.0 0.0 5.317. 0.0 FDC 1000.0 0.0070 0.0 80.484 0.560 Vel = 6.41 I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Western Fire Protection Inc Page 5 Westin Hotel - Hose Valve Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn I FDC -1000.00 7.98 T 46.522 10.208 139.791 to 140.0 0.0 46.522 0.0 UG3 0.0 0.0 0.0 56.730 0.0 Vel = 0 UG3 0.0 11.65 3E 95.65 125.167 139.791 I to 140.0 2T 141.704 283.408 0.0 UG4 0.0 0.0 3F 46.054 408.575 0.0 Vel = 0 UG4 0.0 11.65 3E 108.672 57.750 139.791 I to 150.0 F 17.441 206.611 2.901 * * Fixed Loss = 5.5 TEST 0.0 0.0 T 80.498 264.361 0.0 Vel = 0 Zaf 0.0 I 0.0 0.0 142.692 K Factor = 0 I I I I I I I I I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087