Loading...
HomeMy WebLinkAbout3136 CARLSBAD BLVD; ; FPC2017-0350; PermitI :1JI I1 IIs]:i (ity of Carlsbad 1I1IFi 17 Print Date: 03/02/2022 Job Address: 3136 CARLSBAD BLVD, CARLSBAD, CA 92008-2908 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2032502600 Track #: Valuation: $11,266,343.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2017-0350 Status: Closed - Finaled Fire Alarm Applied: 11/28/2017 Issued: 12/15/2017 DEV05019 Finaled Close Out: 12/08/2020 Inspector: Final Inspection: Project Title: DKN HOTEL Description: SPRINGHILL SUITES MARRIOTT -FIRE ALARM (NEW) Applicant: FPContractor: WEST COAST FIRE AND INTEGRATION INC WEST COAST FIRE AND INTEGRATION INC DALTON AMMANN 3199 AIRPORT LOOP DR, # STE D 3199 AIRPORT LOOP DR, # STE D COSTA MESA, CA 92626-3414 COSTA MESA, CA 92626-3414 (714) 957-5750 (714) 309-9805 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE New Alarm System $1,227.00 FIRE Plan Review Per Hour - Office Hours $132.00 Total Fees: $1,518.00 Total Payments To Date: $1,518.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov C 4 4 )Fire est Coast Alarm • Access Control Dennis Grubb and Associates Plan Reviewer: Dennis Grubb (951) 772-0007 6550 Van Buren Blvd. Suite - E Riverside, CA 92503 Fire & Integration Security • CCTV • Nurse Call • Voice/Data f Z.FC, OPJ Project: Springhill Suites Marriott 3136 Carlsbad Blvd. Carlsbad, CA 92008 Project No.: C7486 B. Administration: 1. Three final set(s) of construction documents will be required during permit issuance. 4. Remove all plans, details or notes that do not pertain to the project from the final set of construction documents. Correction Response to B. I & B. 4: Returning plans for resubmittal with corrections per plan check comments. Submitting (3) corrected sets of plans and separate answer sheet responding to each correction comment per plan check. The following sheets have been clouded and marked with Delta I. C. Fire Alarm - Plan Check Comments 5. The smoke detectors are over-spaced in the Hallways and Great Room. Relocate / add additional smoke detectors as needed per 2016 NFPS 72 § 17.7.3.2.3.1. Correction Response to C. 5: On sheet FAI.40 relocated smoke detector in Great Room. On sheet FAI.41 relocated smoke detector in Hallway. Feel free to contact me personally if you have any further questions. Respectfully, la4"~n Y& Jason Stobie System Designer jstobie@westcoastfireinc.com (714) 957-5750 SALES • DESIGN • INSTALLATION • SERVICE 3199-D Airport Loop Drive Phone (714) 957-5750 Lic.# CIO-989173 Costa Mesa, CA. 92626 Fax (714) 957-5749 ACO# 7407 www.westcoastfireinc.com Dennis Grubb and Associates, ILILC Assisting Cities Build Safe Communities PLAN CORRECTIONS (FIRE) DGA #: C7486 Carlsbad Permit #: FPC20I7-0350 Checked by: D. Grubb Jurisdiction: Carlsbad Applicant: Dalton Annmann Phone#: 714-957-5750 Date of Review: 11/30/17 Project Name: Springhill Suites Marriott Project Address: 3136 Carlsbad Blvd The plans submitted for the project referenced above have been reviewed. The following information is needed to show compliance with the 2016 California Building and Fire Codes (CBC and CFC), and other codes as adopted and amended by state regulation and the City of Carlsbad. It will be necessary to reevaluate the project after the receipt of additional information as specified below. INSTRUCTIONS Resubmit three sets of the revised plans along with one set of the original plans. Provide a written response for each correction on this correction list. You may write directly on this list, or you may provide a separate "Response List" which addresses each correction item by item. Incorporate all corrections into the blue/black line drawings; cloud or call out all corrections. Return plans to Dennis Grubb & Associates, 6550 Van Buren Blvd, Ste E, Riverside, CA. 92503 CORRECTIONS ON THE PLANS THE FOLLOWING SHALL BE PROVIDED: 1. The smoke detectors are over-spaced in the Hallways and the Great Room. Relocate/add additional smoke detectors as needed per 2016 NFPA 72 § 17.7.3.2.3.1. 6550 Van Buren Blvd, Ste E, Riverside, CA. 92503 (800) 9757395 * (951)772-0007 S (. )Fireest Coast Fire & Integration Alarm • Access Control • Security • CCTV • Nurse Call • Voice/Data FPC20I7-0350 3136 CARLSBAD BLVD SPRINGHILL SUITES MARRIOTT - FIRE ALARM (NEW) DEV05019 2032502600 11/28/2017 FPC20I 7-0350 Springhill Suites Marriott 3136 Carlsbad Blvd. Carlsbad, CA 92008 Job# 17-307-00 Fire Alarm System Product Data SALES • DESIGN • INSTALLATION • SERVICE 3199-0 Airport Loop Drive Phone (714) 957-5750 Lic.# CIO-989173 Costa Mesa, CA. 92626 Fax (714) 957-5749 ACO# 7407 www.westcoastfireinc.com S S DN-7070:L • A-b NFS2-3030 NOTI Fl ER® Intelligent Addressable Fire Alarm System by Honeywell General C The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- cations. The NFS2-3030 is part of the ONYX® Series of prod- ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situa- tion, fire progression, and evacuation details. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments; wireless fire protection; and many additional options. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when a marine-listed ver- sion is used with marine-listed compatible equipment. See DN-60688. Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. Wireless fire protection using SWIFT Smart Wireless Inte- grated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. - Detectors can be any mix of ion, photo, thermal, or multi- sensor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Large 16 line, 640 character LCD backlit display or use display-less as a network node. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online/off line program option. NFS2-3030 (left) and NFS2-3030 with DVC audio option (right) With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. EIA-485 annunciators, including custom graphics. History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. Advanced history filters allow sorting by event, time, date, or address. Alarm Verification selection per point, with automatic counter. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM Positive Alarm Sequence (PAS) Presignal. Silence Inhibit and Auto Silence timer options. Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Up to 1000 powerful Boolean logic equations. Supports SCS Series smoke control system in both HVAC and FSCS modes. FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. EIA-232 printer port. EIA-485 annunciator port. DN-70701 • 09/09/2014 - Page 1 of 8 640-CHARACTER DISPLAY FEATURES Backlit, 640-character display. Program keypad: full QWERTY keypad. Up to nine users, each with a password and selectable access levels. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLAsHSCAN@ INTELLIGENT FEATURES Polls up to 318 devices on each loop in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Sensitivity levels: - Ion - 0.5 to 2.50/6/foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.0%/foot obscuration. Sample System Options IN] ... .......... ........FAPT-851 FSL-751 Up o .L LCD-160 FSP-851 LCD2-80 remote FSA-8000 displays ...etc. EIA-485 _____ p. ElA-485 L-J. SMA NEWA CPU2-3030D - display or II 11 LiLJ:LJ.:Li - Acclimate PIusTM - 0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Programmable activation of sounder/relay bases during alarm or pre-alarm. Read Status displays the level of detector cleanliness. FSL-751 VIEWS (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the tire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. SLC Intelligent Loop DEVICES u- I t I FWSG NBG-I2LX T T XP6I10 I/O Modules FMM-1 FRM-1 IDC Relay Contact 3072 annunciator/control points !! !.uI.uIiIi ACM-8R ACM/AEM-24A1 LDM-32 Relay Control LED Annunciator Custom Graphics S o Dual phone lines to Optional 2048-point UDACT Central Station ElA-232 NFS2-3030 Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. Page 2 of 8— DN-7070:L • 09/09/2014 S FAPT-851 ACCLIMATE PLUS TM LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FSA-8000 INTELLIGENT FAAST DETECTOR Connects directly to the SLC loop of compatible ONYX series panels Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. Advanced algorithms reject common nuisance conditions FCO-851 INTELLIQUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE Interface to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds. FM Approved, Class 6320 (Stationary Gas Sensors! Detectors). SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). Solid state message generation. Hard-wired voice control module options. Firefighter telephone option. 30- to 120-watt analog amplifiers (AA Series). Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- tion of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- DN-70701 • 09/09/2014 - Page 3 of 8 NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-413, or in an annunciator box, such as the ABS-213. In CAB-4 top-row applications, a DP-DlSP and two BMP-1 blank modules are required for mounting. Non-English versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For marine applications, order NCA-2-M; for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX. See DN-7047. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 6861. HS-NCM-WIMF/SF/WMFIWSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 6971, ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI software, and computer hardware. See DN-7048 for spe- cific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN is - GW-EM.) See DN-60499. NWS-3: NOTI•FIRE•NETTM Web Server. See DN-6928. CAP-GIN: Common Alerting Protocol Gateway. See DN- 60576. VESDA-HLl-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTl.FIRE.NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACR Charges 7 to 200 AH batteries. Occupies up to five addresses on an SLC, depending on configuration. Primary input power for panel. See DN-6883. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. AMPS-24 uses two 12 volt, 7 to 200 AH batteries. See DN-6933. ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VERIFIRE® TOOLS VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 'Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 5 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, ElA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 5 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-FACP systems (one NFS2-3030D), the display option is the CPU2-3030D. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. MAIN SYSTEM COMPONENTS CPU2-3030D: NFS2-3030 Primary Display. CPU2-3030D ships with keypad/display installed; includes 640-character backlit LCD display, OWERTY programming and control key- pad. CPU2-3030 is a central processing unit and requires an AMPS-24(E) power supply. Non-English versions are avail- able: CPU2-3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2-3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- 3030D-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- tions order CPU2-3030D-M and the appropriate KP-KIT-XX. (See DN-60688.) C131.112-3030ND: CPU2-3030 without display. Non-English ver- sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, CPU2-3030ND-SP, CPU2-3030ND-TC. LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- ers for a total of ten SLCs. See DN-6881. LEM-320: Loop Expander Module. Expands an LCM-320. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-DlSF two BMP-1s, CHS-M3, two LCM- 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- 100, batteries. Page 4 of 8— DN-70701 • 09/09/2014 AUDIO OPTIONS NOTE: See "Enclosures, Chassis, and Dress Plates" on page 6 for mounting hardware. S DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2JDAX Series amplifiers. See DN-60633. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly • with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. RM-1IRM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabinets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 Vrms. AA-100 is 100 watts, 70.7 Vrms. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to ON- 60257. . COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24A1: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-BR: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. Sup- ports Canadian requirements. See DN-6940. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD2-80 (DN-60548). SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. COMPATIBLE INTELLIGENT DEVICES FWSG Wireless SWIFT Gateway: Addressable gateway sup- ports wireless SLC devices. Not appropriate for ULC applica- tions. See DN-60820. FSA-8000: Intelligent FAAST Fire Alarm Aspiration Sensing Technology®. Intelligent aspirating smoke detector. For Cana- dian applications, order FSA-8000A. See DN-60792. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-604 12. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See DN- 6985. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. DN-70701 • 09/09/2014 - Page 5 of 8 FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNR(W). See DN-6935. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851: FlashScan thermal detector 135°F (57C). See DN- 6936. FST-851 R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate PlusTM low-profile multi-sen- sor detector. See DN-6937. FSL-751: FlashScan VIEW® laser photo detector. See DN- 6886. DNR: lnnovairFlex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751PL/FSD- 751 RPL. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224Bl: Isolator base for low-profile detectors. See DN- 60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4' (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1: FlashScan dual monitor module. See DN-6 720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720. FMM-101: FlashScan miniature monitor module. See DN- 6720. FMM-4-20: FlashScan 4-20 mA protocol monitor module. See DN-60411. FCM-1: FlashScan control module. See DN-6 724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FTM-1: Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See DN-6989. FRM-1: FlashScan relay module. See DN-6724. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered separately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See DN- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Order CPU2-3030D-M; for non- English marine applications order CPU2-3030D and appropri- ate KP-KIT-XX. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-3030D/3030ND. CA-2: Chassis for FACP control panel when DVC-EM is used with firefighter's telephone. Mounts in the top two rows of a CAB-4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. DP-i B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2IDAX series or AA-series amplifier. See DN-7046. CHS-BH1: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA2 chassis. See DN-7046. Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMlC-1 microphone and its well (optional). See DN-7045. Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-134 (below). ADDR-134: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-134: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMlC-i is not used. Provides mounting options on right two S Page 6 of 8- DN-70701 • 09/09/2014 S bays for two ACS annunciators, or for blank plates. See DN- 7045. ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2IDAX series or AA-series amplifier. BP2-4: Battery plate, required. CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CHS-4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. Mounts up to six modules in any CAB-4 series row. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power supply, if needed. 30" (76.20 cm) wide x 25" (63.50 cm) high x 7.5" (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. 30" (76.20 cm) wide x 36' (91.44 cm) high x 7.5" (19.05 cm) deep; depth includes door. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24' (610 mm) wide x 14" (356 mm) high x 7.75" (197 mm) deep. Door: 24.125" (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625' (approx. 1.6 mm) to depth. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure. Black; for red, order BB-UZC-R. See DN-3404. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411UDAC: Digital alarm communicator. See DN-6 746. IPDACT-2, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IF See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red; for black, order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ...........1 expandable to 10 Intelligent detectors..........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.............................over 2000 ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24AT/-48A. SPECIFICATIONS Primary Input Power: - AMPS-24:110-120 VAC, 50/60 Hz, 4.5 A maximum. - AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum. DC Output: - Main 24 VDC: Up to 5.0 A - Aux 24 VDC: Up to 5.0 A -5VDC: Up to 0.15 A. Current draw (Standby/Alarm): < - CPU2-3030D board: 0.340 A. - CPU2-3030ND board: 0.120 A. - LCM-320: 0.130 A. - LEM-320: 0.100 A. - AMPS24(E)*: 0.13 A. (Draws power from secondary power source only.) NOTE: See AMPS-24(E) Manual 51907 for a complete current draw calculation sheet and details of input and output values. Battery charger range: 7 AH - 200 AH. Use separate cabinet for batteries over 26 AH. Float Rate: 27.6 V. SHIPPING WEIGHT CPU2-3030D: 5.95 lb (2.70 kg). CPU2-3030ND: 2.90 lb (1.32 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C * 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. MEA: 232-06-E. Fire Dept. of New York: COA#6114. CSFM: 7165-0028:0224 (Commercial). FM Approved. FM6320 Approved. Class 6320 for Gas Detection. City of Chicago. City of Denver. Singapore Productivity and Standards Board (PSB). DN-70701 • 09/09/2014 - Page 7 of 8 CCCF listed. Fire Services Department (Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). Lloyd's Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-3030 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). (NFS2-3030 version 20 or higher) LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). CBC 2007 (Seismic). S InteIliQuadTM, NOTI.FIRE.NEPM, ONYXWorksTM, and SWIFTTM are all trademarks; and Acclimate® PIusTM, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are all registered trademarks of Honeywell International Inc. ©2014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. = b We cannot cover all specific applications or anticipate all requirements. 1311111111111111111 & MANIFACT11111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8 of 8— DN-70701 • 09/09/2014 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0224 Page 1 of 4 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Model NFS-3030, NFS-3030E, NFS2-3030, NFS2-3030E fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), automatic, manual, waterfiow and sprinkler supervisory services. Suitable for use as a releasing service, Emergency Voice/Alarm Communication System and Process/Energy Management Equipment. Refer to listee's data sheet for detailed product description and operational considerations. System components: AA-30/-100/-120; Amplifiers ACM-8R1-1 6AT/-24A1/-32A/-48A; Annunciator Control Modules ACPS-610; Addressable/Charger Power Supply ACPS-2406; Addressable Charger/Power Supply ACT-1/-2/-4/-25/-70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Doors AEM-1 6AT/-24AT/-32N-48A; Annunciator Expander Modules AFM-1 6A/-I6AT/-32A; Annunciator Fixed Modules AKS-1B; Annunciator Key Switch AMG-1 /-E; Audio Message Generator AMPS-24, CPS-24; Addressable Main Power Supply APS-6R, APS2-6R; Auxiliary Power Supply ARM-4; Auxiliary Relay Module BDA-25V/-70V; Backup Digital Audio Amplifiers BGRA-SCS, BGRB-SCS, CEF-SCS, RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station BB-17/-25/-100/-200; Battery Box BMP-1; Blank Module BP-4; Battery Panel BP2-4; Dress Panel CA-1/-2; Chassis CAB-3/4 Series, EQ Series; Enclosures *CABRP CAB-RPR; Cabinets CHG-120; Battery Charger CHS-4L/-4MB/-4N/-6/-M3/-PS/-BH1; Chassis CMIC-1, CMlCRP*; Microphone Assembly CPU2-3030D/CPU2-3030ND; CPU Board *Rev. 05-08-12 gt This the listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct i operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 2 of 4 CRE-4; Control Relay Expander CRM-4RK; Control Relay Module CRT-2; Display Terminal DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers, Fiber Mode DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF Series; Digital Audio Amplifiers DAA-PS; Power Supply DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DCM-4RK; Dual Channel Module DP-1B; Blank Panel DP-DlSP; Display Dress Panel DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-134, DR-13413, DR-134BR, DR-B4R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DPDW-1B, DPSW-IB, XPDP; Dress Panels VP-2B, DPA-1/-1A4/-2; Dress Panels DPI-232; Direct Panel Interface DVC-AO; Digital Voice Command DVC-EM; Extended Memory fl DVC-EMF/DVC-EMSF; Digital Voice Command/Ext Memory DVC-KD; Keypad Board *DvC..Rpu; Remote Paging Unit EQBB-B4, EQBB-C4, EQBB-04; Backbox Assembly EQDR-B4, EQDR-C4, EQOR-D4; Door Assembly FCM-1-REL; Releasing Control Module FCPS-24S6/S8; Field Charger/Power Supply FFT-7/-75; Fire Fighter's Telephones FlRSTVlSlON-LCD; Interactive Firefighters' Display FlRSTVlSlON-ENC; FirstVision Backbox Enclosure and Door FMM-4-20; Analog Input Module FHS; Fireman's Handset FCM-1; Addressable control module FDM-1; Dual monitor module FORM-i *; Dual Relay/Monitor Module FMM-l; Monitor module FMM-101; Miniature monitor module *Rev. 05-08-12 gt øT1 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S Listing No. 7165-0028:0224 Page 3 of 4 FRM-1; Addressable relay module FTM-1; Firephone Control Module FPJ; Fireman's Phone Jack FZM-1; Two-wire detector monitor module HS-NCM-W/-MF/SF/-WMF/-WSF/-MFSF; High Speed Network Control Modules ICE-4; Indicating Control Expander ICM-4RK; Indicating Circuit Module IPDACT-2/-2UD/IPENC; IP Digital Alarm Communicator ISO-X; Isolator Module IZE-A; Initiating Zone Expander IZM-8RK; Initiating Zone Module LCD-80, -160; Liquid Crystal Display Module LCD2-80; Liquid Crystal Display LCM-320; Loop Control Module LDM-32/-E32/-R32; Lamp Driver Module LEM-320; Loop Expander Module MP-113; Blank Panel MPS-2413; Power Supply Module NBG-12; Series Addressable Manual Pull Station NBG-12LX; Manual pull station, addressable. See DN-6726 NCA/NCA-2; Network Control Annunciator NCM-W/-F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station, Wire/Fiber NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station, Wire/Fiber ONYXWorks-EW/-NW/NF/-HNW/-HNMF/-HNSF/-TSI-EW-TS/-NF-TS/-HW-TS/-HNMFT/ -HNSFTI- HNWT; Graphics PC workstation for NOTI-FIRE-NET Wire/Fiber/with Touch-screen monitors S N-ELR; End of Line Resistors NFS-LBB/-LBBR; Battery Box PRN-6; Printer R-120/-2.2K/-27K/-470/-47K; End of Line Resistors RA-400/400Z; Remote Annunciators RKS-S; Remote Security Keyswitch RM-1/-ISA; Remote Microphone RPJ-1; Remote Paging Jack RPT-W/-F/485W/-485WF; Repeater SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly SCS-8; Smoke Control Station SCS-8L; Smoke Control Lamp Driver Station SCE-8; Smoke Control Expander SCE-8L; Smoke Control Expander Lamp STS-1; Security Tamper Switch *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 4 of 4 TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256/BB--UZC; Universal Zone Coder/Backbox VCE-4; Voice Control Expander VCM-4RK; Voice Control Module VS4095/5; Keltron Remote Printer XP5-CI-M; Transponder XPC-8; Transponder Control Module XPlQ; Transponder Quad Intelligent Audio Module XPM-8/-8L; Transponder Monitor Modules XPP-1; Transponder Processor XPR-8; Transponder Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units suitable for high rise applications for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined with Listing No. 7170-0028:223 S *Rev. 05-08-12 gt ri.° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SRD ACE-Il SYSTEM RECORD DOCUMENTS The SRD is the perfect item to help you meet demanding code requirements today. NFPA 72 2013 7.7.2.4 states that a cabinet must be "prominently labelled 'SYSTEM RECORD DOCUMENTS'." The SRD is the perfect fit to meet todays demanding code requirements. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2013 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 41313 USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the software not being on site when technicians arrive to service the system. Along with your fire alarm software you can store your test & inspection, service records, manuals & system records. Using a standard USB B connector you may also store you records electronically (See NFPA 72 2013 7.5.6.7). The SRD has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has an organized record for identifying equipment information, required documentation locations (See NFPA 72 2013 7.2.1). L Standard Features: Installed with a 4 GB digital flash drive with USB B connector 2 key ring hooks to hold system keys Business card holder for key contacts Overall dimensions are 12" x 13" tali and 2 1/4" deep 18 gauge steel box and cover for security Durable powder coat baked on finish other colors available Standard 3/4" cat 30 key lock. Other lock assemblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "SYSTEM RECORD DOCUMENTS" Legend sheet for documentation, passwords and system information Electronics Inc. 1S09,001- MNFPA COMPANY 800.486.1723 Toll Free BER Made I.S.A. REGEED,/Tsa!om' 508.485.0966 Local 7M n~U Space Age Electronics, Inc. 2013 ED0584 LT10641 Rev.A 1/2 No Excuses, Just Solutions! I SPACE AGE 7ELECTRONICS, INC. Specifications: 0 The system record documents box (SRD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with I" high lettering "SYSTEM RECORD DOCUMENTS "with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system informattqp. The SRD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a staIdard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. Ordering Information: Part # Description SSU00689 System Record Documents Cabinet Space Age Electronics, Inc. SSU00690 Custom screening with you door legend sheet r Logo 1 Toll EA0315 10 pack800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0584 LTI 0641 Rev.A 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFI, IFX/A and IFX/D enclosures. Models ACE-11, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S DN-6940:131 •D-115 LCD-160 NOTI Fl ER® Liquid Crystal Display by Honeywell General The LCD-160 is a 640-character Liquid Crystal Display (LCD) annunciator and remote control for the NOTIFIER NFS-30301 NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030's 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and can display other panel information. LCD-160 Features 640-character Liquid Crystal Display with backlit control. On-board input, output, and status indicators to support diagnostics. Software upgrades and foreign-languages character sets via serial port from a panel or other device using the Remote Data Port (RDP) interface. Upgrades do not require the replacement of any programmable devices. Rubberized keypad. Input for AKS-1 B key switch. Fits in two ACS annunciator module locations. Display and Control Center (DCC) participation/indication. RDP Interface Any communication between the control panel and any RDP device, such as the LCD-160, occurs over an RDP interface. RDP interface communication is supervised by the FACP and the LCD-160. RDP bus can drive up to 32 RDP devices. The FACP must be at one end of the bus; the last RDP device on the circuit must have an enabled end-of-line resistor. Each LCD-160 on the bus requires a non-resettable 24 VDC power connection. The power circuit is inherently supervised and a loss of power registers as a communica- tion failure at the control panel. The LCD-1 60-can be powered by a regulated remote power supply listed for fire-protective signaling use. If the 24 VDC power comes from a non-power-limited source, it must remain separate from the power-limited RDP bus. Specifications Input supply voltage (T132): Regulated, filtered 24 VDC via non-resettable power supply interface listed for fire-protective signaling use. Sources can be: panels with integrated power supplies, main power supplies (AMPS-24, etc.), auxiliary power supplies (APS2-6R, etc.); or a compatible accessories output. If RDP devices are to be powered by separate power supplies, a common reference connection must be estab- lished. Data communications port (TB1): Power-limited RDP inter- face. Current draw: Standby current: 0.300 A with backlight on, 0.075 A with backlight off. Alarm current: 0.325 A with back- light on, all LEDs active. RDP BUS WIRING SPECIFICATIONS Wiring distance: 4000 feet (1219.2 m) at 18 AWG (0.78 mm2) between the panel and the last device on the RDP bus (sub- ject to system's power restrictions). Wiring size: 18 to 12 AWG (0.78 to 3.1 mm2) twisted-pair cable, with characteristic impedance of 120 ohms ± 20%. Wire resistance: Limit total wire resistance to 100 ohms on the RDP bus, and 10 ohms on the RDP device power circuit. Unloaded resistance between RDP connectors must be greater than 1K ohm. A remote power supply is required if total power wiring resistance exceeds 10 ohms. NOTE: 1) DO NOT RUN CABLE adjacent to, or in the same con- duit as: 120 VAC service; "noisy" electrical circuits that are power- ing mechanical bells or horns; audio circuits above 25 Vrms; motor control circuits; SCR power circuits; or non-power-limited circuits. 2) Refer to LCD- 160 Manual, document no. 51850, if RDP devices are to be mounted in SEPARATE CABINETS or powered by REMOTE POWER SUPPLIES. PHYSICAL SPECIFICATIONS Temperature/humidity range: This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F Shipping weight: 2.50 lb. (1.134 kg) DN-6940:B1 • 8/31/2011 - Page 1 of 4 LCD-I60 Interface and Indicators The liquid crystal display is 40 characters wide and 16 lines deep, and displays all programming screens and other infor- mation. The keypad is functional only when an entry is requested by the system. Enter or change fields and issue commands on the display by using the two types of keys on the keypad: fixed function and soft keys. Fixed function keys are the ten keys labeled on the front of the LCD-1 60, operating at all times on all screens unless oth- erwise noted. With both an active command center and DCC enabled at the panel, Acknowledge, Signal Silence, System Reset, and Drill require permission before they can be pro- cessed. Acknowledge: Press to respond to any event or trouble sig- nal. If enabled, silences the LCD-1 60 piezo sounder. Sends an acknowledge message to the panel. Signal Silence: Press to send a system silence command to the panel, with the particular silencing action information stored at the FACP. Verification screen appears on networked displays. System Reset: Press to send a system reset command to the panel, with the particular reset action information stored at the FACP. Verification screen appears on networked displays. Drill: Press (hold for two seconds) to activate all silenceable fire output circuits. Lamp Test: Press to test the LED indicators and the piezo, or display firmware version numbers. Fire Alarm: Scroll/display a list of associated events. Security: Scroll/display a list of associated events. Supervisory: Scroll/display a list of associated events. Trouble: Scroll/display a list of associated events. Other Event: Scroll between preaarm and disabled events. For complete information on key functions and effects on dif- ferent panels, refer to the LCD-160 Manual and panel manu- als. Soft keys are the six keys to the right and left of the display. Use them to select commands that appear on the display for each different screen. Refer to the screens in the LCD-160 Manual for descriptions of the applicable soft keys. STATUS LED INDICATORS Power (green) illuminates when AC power is within normal operating limits. Fire Alarm (red) illuminates when at least one fire alarm event exists. It will flash if any of these events are unacknowledged. Pre-Alarm (red) illuminates when at least one pre-alarm event exists. It will flash if any of these events are unacknowledged. Security (blue) illuminates when at least one security event exists. It will flash if any of these events are unacknowledged. Supervisory (yellow) illuminates when at least one supervi- sory event exists. It will flash if any of these events are unac- knowledged. System Trouble (yellow) illuminates when at least one trou- ble event exists. It will flash if any of these events are unac- knowledged. Other Event (yellow) (future release). S NUP .jIIL 4 J3 ftj JI LCD BACKLIGHT LCD-1 60 KEY SWITCH J2 1 2 = = LCD 19'-2O C 'POWER __iauonuI1nDaonnoDu IjUOOOUOOOUUd': L_____J IN STATUS +24VDCOUTTB (IIIOIIIUIRIRIIRIIIIIIHIIII' COMMON IN LEDII COMMON OUT RDP TB1RDP+ MICRO FAIL == j,RDP+ 1-614 RECEIVE -- RDP- -- RDP—. naouonuuu0000a SWI7 LEDI2 REF C REF C TRANSMIT EARTh LEDI3 Page 2 of 4— DN-6940:B1 • 8/31/2011 ACKNOWLEDGED TROUBLE ELEVATOR LOBBY EAST WING FIFTH FLOOR Z239 SMOKE (PHOTO) 11:58:45A WED JUN 26, 2003 L03DD02 EVENT COUNTS FIRE ALARMS:000 PREALARII:000 TROUBLE:001 SUPERVISORY:000 SECURITY:000 DISABLE:000 11:58:46A WED JUN 26, 2011 SIGNAL SILENCE MORE INFORMATION SYSTEM RESET PROGRAM MENU Signals Silenced (yellow) illuminates if notification appli- ances have been silenced. It flashes if some, but not all, of the NACs have been silenced. S Point Disabled (yellow) illuminates when at least one device has been disabled. It will flash until all disabled points have been acknowledged. Controls Active (green) illuminates when the LCD-160 assumes control of the node as a primary display. DIAGNOSTIC LED INDICATORS Status, LED1 1 (green), blinks when the LCD-1 60 is on. Visi- ble to the installer/troubleshooter only. Receive, LED1 2 (green), blinks when data is received from the panel. Visible to the installer/troubleshooter only. Transmit, LED1 3 (green), blinks when data is transmitted to the panel. Visible to the installer/troubleshooter only. Microfail, LED14 (yellow), illuminates if the microcontroller fails. Visible to the installer/troubleshooter only. Event Handling and the Display and Control Center UL and ULC require that when multiple command and control centers are installed, only one operator at any location can be in control at any given time for functions such as acknowledge, silence, and reset. This is called the Display and Control Cen- ter (DCC). DCC operation provides a mechanism to pass net- RDP Bus Wire Runs LCD-160 Power FACP 12to18AWG LCD-1 60 I Two-wire RDP Bus - - - - - 4000 feet (1219.2 m) max. power-limited and supervised Sample Screen: Point Event Display work control to alternate network control centers. This protocol allows for a "request for control" from another networked panel, which will be accepted or rejected from the current DCC. A 15-second time-out allowance provides for an auto- matic passing of control in the event there is no response from the original DCC. If the NFS-3030/NFS2-3030 panel associ- ated with an LCD-160 has been programmed to participate in DCC, all remote displays with Local Control ON will automati- cally participate. Agency Listings and Approvals These listings and approvals apply to the LCD-160. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S635 ULC: S635 MEA: 8-04-E (annunciator only) FDNY: COA#6065 (with NFS2-3030) CSFM: 7120-0028:0227, 7165-0028:0224 FM Approved DN-694031 • 8/31/2011 - Page 3 of 4 Product Line Information LCD-160: 640-character Liquid Crystal Display annunciator Backboxes The following backboxes can be surface- or semi-flush- mounted to provide an enclosure for remote mounting. Use with 1/2 (1.27 cm) conduit in the provided knockouts. ABS-2101 (black) and ABS-2DR (red): Surface- or semi-flush enclosure for remote mounting. Mounts an LCD-1 60 directly to the enclosure's hinged dress plate. The ABS-2D and ABS- 2DR do NOT support the installation of the AKS-1B key- switch. Not for use in Canadian applications. Optional trim ring TR-ABS2D for semi-flush mounting. Dimensions, box: 12.0" (30.480 cm) H x 12.0" (30.480 cm) W x 3.797' (9.644 cm) D (NOTE: The black ABS-20 is slightly deeper). Dimensions, door: 12.0' (30.480 cm) H x 12.0 (30.480 cm) W x 1.250' (3.175 cm) D. ABS-41) (black) and ABS-4DR (red): Surface- or semi-flush- enclosure for remote mounting. Mounts an LCD-160 and two annunciators directly to the enclosure's hinged dress plate. The ABS-4D and ABS-4DR do NOT support the installation of the AKS-1 B key-switch. Dimensions, box: 11.97' (30.40 cm) H x 19.87 (50.47 cm) W x 3.5" (8.89 cm) D. Dimensions, door: 11.97' (30.40 cm) H x 19.87' (50.47 cm) W x 1.250" (3.175 cm) D. ABF-2B: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Not for use in Canadian applications. Includes a painted black metal trim plate [11' (27.94 cm) high x 10.625" (26.99 cm) wide] and adhesive-backed annunciator label. 9.938" (25.24 cm) high x 9.188" (23.34 cm) wide x 3.75" (9.525 cm) deep. ABF-2DB: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Does not support the installation of AKS-1B. Box dimensions: 9.938' (25.24 cm) high x 9.188" (23.24 cm) wide x 3.75" (9.525 cm) deep.Door dimensions: 11(29.94 cm) high x 10.375" (26.35 cm) wide x 0.75" (1.9 cm) deep. ABF-4B: Black flush enclosure for remote mounting of one LCD-160 and two annunciator modules directly to the enclo- sure's dress plate. Knockouts are provided for use with 1/2' (1.27 cm) conduit. Includes a painted black metal trim plate [11(27.94 cm) high x 19.375" (49.21 cm) wide] and an annun- ciator label. 9.938" (25.24 cm) high x 17.75" (45.09 cm) wide x 2.5" (6.35 cm) deep. CAB-4 Series cabinets: Surface- or semi-flush-mounted, in sizes to accommodate one to four rows of equipment plus bat- teries (up to two 26 AH batteries). Four sizes are available. Doors are ordered separately, and feature reversible hinges to mount doors on the left or right side. Doors also open a full 180°. Keylocks are included. For dimensions and further infor- mation, see datasheet DN-6857. ACCESSORIES DP-DISP: Dress Panel Display for cabinet mounting of an LCD-160. LCD-160 mounts directly to the dress panel, which hinge-mounts to the top tier of a CAB-4 Series backbox. ADP-4B: Annunciator Dress Panel-413 (black) for cabinet mounting of an LCD-160. LCD-160 mounts directly to the dress panel, which hinge-mounts to the tier of a CAB-4 Series backbox. TR-ABS2D: Optional trim ring for semi-flush mounting ABS- 2D(R). VP-213: Vented Dress Panel for use with the ADP-413 dress panel installed in the top tier of a NOTIFIER cabinet. It covers the gap between the dress panel and top of the cabinet. AKS-1 B: Annunciator Key Switch provides access security for the control switches on the LCD-160. Key-switch kit includes key, hardware, and an annunciator label. NOTIFIER® is a registered trademark of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. S S This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINERINS &MNIMCfflN wig All specifications are subject to change without notice. QUALITY SYSTEMS Made in the lJ.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4- DN-6940:1211 • 8/31/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0227 Page 1 of I CATEGORY: 7120 -- ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneyweII.com DESIGN: Model *LCD..160 annunciator control system. Unit has the ability to display custom messages, graphics and mirror the compatible FACP display annunciation. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit consists of the following modules: ABF-213, 413 Enclosures ABS-2D/-2DRI-40/-4DREnclosures CAB 4 Series Enclosures ADP-4B Annunciator Dress Panel DP-DISP Dress Panel VP-2/-2B Vented Dress Panel AKS-1, -lB Annunciator Key Switches RATING: 17.6-30Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. S MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an annunciator for use with separately listed compatible Model NFS-3030 fire alarm control unit (CSFM Listing No. 7165-0028:224 & 7170-0028:223). Refer to listee's Installation Instruction Manual for details. *Recel.t 04-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not v" an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to verify correct listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Each output and be independently configured for various applications and installations. Each output can be independently configured for Class A or Class B operation, constant power, ANSI Temporal Code 3, Single, Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal S flexibility in new and retrofit installations. The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Description The PSN series of notification power supplies offers reliable notification Sensof® strobe devices. Each output can be configured the same sync power with unprecedented versatility. The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. Each output is rated at 3 amps and it may be used continuously without any derating. The power supply operates on either 120 VAC or 220 VAC power input and has a regulated 24 VDC output. In addition, the panel can charge up to 55 AH batteries and leads the industry in housing up to 18 AH batteries. The cabinet is constructed out of 18 gauge cold rolled steel and has a durable red powder coat finish. In addition, a key lock is provided for securing the door. Ample electrical knockouts are provided on the sides and the top, allowing the installer options for running wires and maintaining the correct separations. The power supply offers an industry leading Quadrasync function that allows for multiple strobe circuits of different brands to be synchronized to flash at the same time. The panel can have four different brands each connected to its own circuit and all of the strobes flash together. Each output can independently be configured to provide one of In addition, the panel has an input PassThru mode allows the outputs to follow the input signal and sync up the input flash. The panel will recognize the type of input being supplied and pass this through to the outputs with the same pattern. This input pass through can be selected on each output independently. The power supply contains simple dipswitch programming and LED indications providing the installer indications of the operation and the ability to correct any faults. A Trouble Memory is provided to allow an installer to review past troubles and make the necessary repairs. Each output has an LED to pin point the exact circuit where a problem may have occurred. Relays are provided for monitoring the general system and AC failure. ® POTTER The Symbol of Protection palent pending c®uS $ LISTED S2930 7315-0328:0189 Product includes a 5 year warranty • Dimenions: 16 1/8W x 16 3/4'H x 3 1/2'D Stock Number: 3006436 PSN-64 Red Enclosure 3006437 PSN-106 Red Enclosure 3006446 PSN-106 Black Enclosure PSN SERIES POWER SUPPLY UL, cUL, CSFM Listed PSN-64 has 6 amps regulated with 4 Outputs PSN-106 has 10 amps regulated with 6 Outputs Outputs Rated at 3 amps maximum each May be configured as up to three class "A" Style "Z" notification circuits 3 amp, 24 VDC programmable output power Supervised Battery Charger: 27.3 @ 1A (supports 7-55 AH batteries) Easy to install cabinet with leveling mounts and key lock Wiring knockouts provided on sides and top of cabinet Two Trouble Relays (5A at 30VDC) General System Trouble (programmable for AC delay) Low AC Trouble with optional delay settings Diagnostic LED's Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault (Amber),AC (Green), Battery Fault (Amber) Trouble Memory feature captures troubles which have previously restored Synchronized notification appliance circuits Potter/AMSECO®, Wheelock®, Gentex®, System Sensor® Configurable output circuits (DIP switch sets options for each circuit) 15 mA at 8-33 VDC input trigger Reference EOL allows 2K - 27K EOL value to be used Quadrasync provides panel wide synchronization of same or multiple brands PassThru mode allows the Outputs to match the Input Signal Electrical Specs: 120/240 VAC 50-60 Hz input 5.l Amps @ 120 VAC or2.5 Amps @24OVAC Standby Current 60 mA Alarm Current 200 mA* *no external load Potter Electric Signal Co., LLC • St. Louis, MO • Cast Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT. #8910013 - REV C2 PAGE 1 OF 2 11/12 -. LOW Ac TROUBLE NCCOMNO NCCOMNO Common relays are non-power limited. €!- POTTER The Symbol of Protection PSN SERIES POWER SUPPLY is PSN-106 Wiring Diagram 120 VAC 50Hz-6OHz 240 VAC 50Hz-60Hz Connect to separate unswitched AC circuit COT [ 120/240 VAC [J Jumper Position Cq Black —White GND FAULT DETECT ENABLE oNJ OFF Status LED's S S S • • • • S7 -St IUlllllll} IBli 11111 00 ~F.se Do 11 0 o = ILFOfOSl I 0 0 0 - Interconnect. AC Power El E El EHH I Low Battery I II (2nd PoutS Comm [II 1:1 [I El F-1[II] Bulk Options LI _____ NAC2 -L3 NAC4 NA-NAC6 yCP7R Buttery + \\ Rofoinuce 00 L DC Power Trigi MUM Battery connection (non-power limited). Note: PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two (2)12V batteries connected in series. supply is triggered. There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply. The power supply shall operate on either 120 or 240 VAC input. The panel shall be capable of continuous load power without any degradation to the main supply or the distribution board. The cabinet shall be capable of housing up to 18 AR batteries and the panel shall be capable of charging up to 55 AH batteries in an external cabinet. The panel shall have dip switches for simplistic configuration of the system and LEDs to provide visual indication to the installer of the status of the system. The dip switches shall allow for AC power delay selection, Class A/B operation per output, Door Holder Power options, constant auxiliary power, trigger input type, ANSI Code 3 Temporal Code, Pass Thru (input tracking), Potter/AMSECO® sync, Gentex® Sync, System Sensor® Sync or Wheelock® sync. The LEDs shall provide indication of communication between the power supply and distribution circuit assemblies. The LEDs shall have distinct flash patterns to provide further indication ofthe troubles present. The panel shall have selectable Trouble Memory to provide the installer an indication that a past trouble existed on a circuit for diagnostic purposes. Each output of the power supply shall be capable of 3 amps of continuous powerwithout degradation overtime. The power supply shall provide for multiple circuits of strobe appliances. The power supply shall synchronize the flashes of any of the above listed strobe appliances on a per circuit basis. Up to four different strobe circuits may be connected and all of the strobes shall flash in unison as required by UL 864. In addition to this Quadrasync feature, the panel shall allow any of the four above mentioned sync patterns as an input and pass this signal through and synchronize the outputs to match the input flash pattern. 0 PRINTED IN USA MKT. #8910013 - REV C2 PAGE 2 OF 2 11/12 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0328:0189 Page 1 of I CATEGORY: 7315 -- POWER UNITS LISTEE: Potter Electric Signal Col 609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignaI.com DESIGN: Models PSN-I06, PSN-64, PSB-10 Notification Appliance Circuit (NAC) Power Supply Units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input 120/240 VAC 50/60Hz Output 24VDC @ 1 O INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the unit must provide battery backup suitable for at least 24 hours. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. 01-27-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG-7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD t COMMERCIAL FIRE PRODUCT FEATURES I Certified for use on the AT&T LTE network for long, sunset-free installation. I- Meets UL 864 requirements for sole, primary or backup path communications. I Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/40 if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. VOLY TG-7FS LTE-A CELLULAR ALARM COMMUNICATO1 FOR LTE NETWORK, TELG UARD ji-K1II± Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 Central station burglar alarm units: Line security servcies Residential 985 Household fire warning systems 1023 Household burglar alarm systems ULC Listings S545 Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telcjuard.com. SECURITY SIGNALING SECURITY C us ASSOCIATION' NFPA LISTED INTERNATIONAL by AT&T Telguard, a Division of Telular Corporation 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 • USA 800-229-2326. Option 5 • www.Telguard.com • Copyright c 2017 Telular Corporation All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosarajutelular.com DESIGN: Models *TG7LM0I *TG7LA00I *TG7lJF01 and *TGKlTIJ1 digital cellular radio alarm transmission system for fire/burglar alarm syste I units. Models **TG7L,a.p01 *TG7LA00I are household application. Mod *TG7FO1 nd *TGKITLAI are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This . product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 01-04-2017 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct J*V% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TELGUARD I CELLULAR ALARM TGm7FS COMMUNICATOR P/N:TG7GFSO4 FOR 3G/4G NETWORKS a COMMERCIAL FIRE PRODUCT FEATURES I- Meets UL 864 requirements for sole, primary or backup path communications. I- Provides RMR protection by leveraging technology that operates on 30/4G networks. I- Supports listen-in, two-way voice verification over cellular. I- Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7ES, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. UL Listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units: Line security servcies Residential 985 Household fire warning systems For the most current product specifications and UL Listings visit www.Telguard corn. I] PMWWM ELECTRONIC LISTED INTERNATIONAL TG=7FS CELLULAR ALARM CCMMUNICATO FOR 3G/4G NETWORKIJ TELGUARD P/N: TG7GFS04 Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. Telguard, a Division of Telular Corporation • Cumberland Center IV 3225 Cumberland Blvd Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 • www.Telguard.com • Copyright C 2012 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM n LISTING SERVICE LISTING NoT 7300-1402:0110 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES IF CALi FIRE LA Page 1 of I LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosarajutelular.com DESIGN: Models *TG7LVO01 *TG7LVA01 *TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. C *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division r DN-6724:B3 FCM-1(A) & FRM.1(A) NOTIFIER® Series Control and Relay Modules by Honeywell General S FCM-1 (A) Control Module: The FCM-1 (A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 - 99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style V or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheef (DN-60390) for new FlashScan@ releasing applications. Construction The face plate is made of oft-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). 7~7 FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAG). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1 (A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAG shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. Contact Ratings for FRM-1 (A) External supply voltage (between Terminals T1 and Til): Maximum (NAG): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM..1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C) Humidity range: 10% to 93% non-condensing. Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 30 VDC Inductive Coded (LIR=5ms) 1A 30 VDC Inductive Coded (L/R2ms) A .3 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF0.35) Non-Coded Inductive 2 A 25 VAC (PF0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W 11 Dimensions: 4.5" (114.3 mm) high x 4° (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 IJLC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document /56-1169. FRM-1(A) Installation document /56-3502. Notifier SLC Wiring Manual, document 51253. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. 0 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I S0 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MCINERINS & MANUFACTUMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 S DN-6720:C • H-220 FMM.1 (A), MM-101 (A), FZM.1 (A) & FDM-1 (A) Monitor Modules with FlashScan® by Honeywell General S S Four different monitor modules are available for Notifier's intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3(3.302 cm) H x 2.75 (6.985 cm) W x 0.5' (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class FMM-1(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5 (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 cm) deep box. DN-6720:C • 10/06/2010 - Page 1 of 4 FMM-1 01(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 - 99 on CLIP loops. 1415 0 1 ADDRESS 0 1 c LOOP 8 7 6 0~. " TENS ONES oul •O - - UJ • UJ 0 Or ca The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-1 01(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3 (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 (A) Interface Module S Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMFIRFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5 (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 cm) deep box. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for 40 Style D application. Page 2 of 4— DN-6720:C • 10/06/2010 FDMI (A) Dual Monitor Module The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire S initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM- 1(A) provides two Style B (Class B) IDC circuits ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 490C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. F0M-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically S assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM- 1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1 (A), FZM-1 (A), and FDM-1 (A) modules mount directly to a standard 4" (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-1 01(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 S . FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-1I-101, FZM-1) - 94/60004/E2 (AFP-200: except FDM- 1) - 02/60007 (NFS -640: FDM-1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01 (A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:C • 10/06/2010 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENCRIERINS & MANIFACTIMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:C • 10/06/2010 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. • 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not RVt an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Multi-Voltage Conventional Relays S System Sensor's multi-voltage conventional relays are used for high-current switching applications such as On and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 01/201 and R-1 4T/24T Removable front cover on steel enclosure for R-1 OE/R-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware The R-1 OT, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-1 OT is a single FORM—C (SPDT) relay with a red activation LED, and the R-1 4T is a four-gang 1 FORM—C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM—C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM—C (DPDT) relay with four red activation LEDs. The R-1OE!R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-i IPR-2IPR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR-3 is identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-i is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Agency Listings MEA approved LISTED PR-i EOLR-1 PR-3 R- IOE & R-20E Enclosure PR-2 R-14T S 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2 Fax: 630-377-6495 R-10T 20117 System Semmsor. Product specification, subject to change wmthout °00ce. Visit systemesensom.coes for current product information, including the latest version of this data sheet. A05-0372-005 .3/07 '#1782 R-14E & R-24E Enclosure Multi-Voltage Conventional Relay Specificatioi Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8 minimum Dimensions 0.91 H x 1.65W x 1.22'lJ Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature -22°F to 140°F (-30°C to 60°C) Humidity Range 10- 93% RH Wire Length 8" minimum Is Operating Voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 15 mA DC max. @24 VDC, 24 VAC, 120 VAC Operating Temperature —40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8" minimum Dimensions 0.871-I x 2.01W x 1.42D Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-1 OT/R-141) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, -- 230 VAC (R-20T/R-24T) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OT/R-201: 2.51 x 3.35W x 1.21-I R-14T/R-24T: 101x3.35Wx 1.21-1 Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 120 VAC: 1/6 HP 230 VAC: 7 A Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-1 OE/R-14E) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature —40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OE/R-20E: 5.11 x 3.75W x 2.51-I R-14E/R-24E: ill x 5.3W x 251-1 Contact Ratings 24 VDC: 7 A with L/R = 5 mS 12O VAC: 1OA 120 VAC: 1/6 HP 23O VAC: 7A CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0172 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Mo els PR-I, - , -3 Multi-Voltage Relay. Refer to listee's data sheet for detailed product descrip i and operational considerations. RATING: PR-11 = 24 VDC/ (+); 24 VAC; 120 VAC, 60 Hz PR-2, -3 = 10-40 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:232 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct vl operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S DN-6936:13 • H-211 (a NOTIFIER® with FlashScan® - by Honeywell - General FST-851 (A) Series Intelligent Thermal (Heat) Detectors Notifier FST-851 (A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851 (A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 135°F/570C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 RIA) in a low-profile package. FST-851H(A) provides fixed high-temperature detection at 190°F/88°C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST- 851 (A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FST-851(A) in B2IOLP(A) Base 94-5V plastic flammability rEtng. Remote LED output connection to optional RA1 00Z(A) remote LED annunciator. Optional sounder, relay, and isolator bases. Optional flanced surface mcunting kit. Features Specifications • Sleek, low-profile, stylish design. Size: 2.1(5.3 cm) high; base determines diameter. S . State-of-the-art thermistor technology for fast response. • Rate-of-rise model (FST-851R/A), 15°F (8.3°C) per minute. - B21OLP(A): 6.1' (15.5 cm) diameter. <-- • Factory preset fixed temperature at 135°F (57°C); high-tern- - B501 (A): 4.1 (10.4 cm; ciameter. perature model fixed at 190°F (88°C). - 13200S(A): 6.875° (17.46 cm) diameter. • Addressable by device. - B200SR(A): 6.875 (17.46 cm) diameter. • Compatible with FlashScan® and CLIP protocol systems. - B224RB(A): 6.2 (15.748 cm) diameter. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 - B224B1(A): 6.2 (15.748 cm) diameter. on FlashScan systems). Shipping weight: 4.8 oz. (137 g). • Two-wire SLC connection. Operating temperature rarge: FST-851 (A) Series, FST- • Visible LEDs "blink" every time the unit is addressed. 851 R(A): —20°C to 38°C (-4.F to 100°F); FST-851 H(A): —20°C • 360°-field viewing angle of the visual alarm indicators (two to 66°C (-4°F to 150°F). bi-color LEDs). LEDs blink green in Normal condition and Detector spacing: UL approved for 50 ft. (15.24 m) center to turn on steady red in Alarm. center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. • Integral communications and built-in device-type identifica- Relative humidity: 10% - 3% noncondensing. • tion. Remote test feature from the panel. Thermal ratings: fixed-temperature setpoint 135°F (57C), rate-of-rise detection 15°F 8.3°C) per minute, high tempera- • Built-in functional test switch activated by external magnet. ture heat 190°F (88°C). • Walk test with address display (an address of 121 will blink ELECTRICAL SPECIFICATIONS the detector LED 12-(pause)-1). • Low standby current. Voltage range: 15 - 32 volts DC peak. • Backward-compatible. Standby current (max. avg.: 300 pA @ 24 VDC (one com- • Built-in tamper-resistant feature. munication every 5 seconds with LED enabled). • Designed for direct-surface or electrical-box mounting. LED current (max.): 6.5 mA @ 24 VDC ("ON"). • Sealed against back pressure. • Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- Use thermal detectors for protection of property. For further S . tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. information, go to systems rs or. com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- • Constructed of off-white fire-resistant plastic, designed to i vdes detailed information or detector spacing, placement, commercial standards, and offers an attractive appearance. zoning, wiring, and special applications. DN-6936:B • 12/07/2011 - Page 1 of 2 Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5 (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747. ULC Listed: S6978. MEA Listed: 383-02-E. FM Approved. CSFM: 7270-0028:0196. BSMI: C1313066760025. CCCF: Certif. #2004081801000018. U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC induc- tive. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B21 OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B21OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes T55-127-010. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. 0 ---------.. FST-851: Intelligent thermal detector. Must be mounted to one of the bases listed below. FST-851A: Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise fea- ture. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. lEIINC & MANIMC1UHIN& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6936:13 • 12/07/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0196 Page 1 of I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kire honeywell.com DESIGN: Model FST- 1 -851, -8 IR, -851H (fixed temperature) and FST-751R (fixed temperature with Rate- - iso) nic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-751, -751R, -851, and -851R = 135°F fixed temperature Model FST-851H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501, *B2IOLP (CSFM Listing No. 7300-1653:0109), or B7IOLP base (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. C *11222016 dc M. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6935:D • H-202 S NOTIFIER® by Honeywell General FSP-851 (A) Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3601 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. FSP-851(A) in 32IOLP(A) Base - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.74e cm) ciameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 1201F). FSP-851(A), D°C. to 38°C (32°F to 100°F). Low temperature signal fcr FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.541C). FSP-85 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 158°F). ULIIJLC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installatioi in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-tempatLra setpoint 135°F (570C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spaci-ig detectors in compliance with NFPA 72. In low airflow appl caons with smooth ceiling, space detectors 30 feet (9.144m) to- ceikrg heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICA TI ONS Voltage Range: 15-32 volts )C pea<. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LEE enabled). LED Current (max.): 6.5mA © 24 VDC ('ON"). Installation FSP-851(A) plug-in detectors ue a separate base to simplify installation, service, and ma itnaice. A special tool allows maintenance personnel to plug ard remove detectors without using a ladder. Mount base (all base types: on ai e.ectrical backbox which is at least 1.5" (3.81 cm) deep. For a c-iart of compatible junction boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases,. consult the ISO-X(A) installation Specifications Sensitivity: 0.5% to 2.35% per foot obscuration . Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1 (15.5 cm) diameter. - B501(A): 4.1" (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. r65:D.12/o8/2o11—Page 1 of 2 sheet /56-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. Ul Listed: S1115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit # 2122. BSMI: C1313066760036. CCCF: Certif. # 2004081801000017 (FSP-8511) Certif. # 2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-3200, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 3200, excluding B21OLP(A)). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. F110BP: Bulk pack of Fib; package contains 15. F210: Replacement flange for B21OLP(A) base. RA1 OOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-200B: White detector covers for use with FSP-851(A) only; box of 10. Product Line Information NOTE: "A" suffix indicates ULC Listed model. -> FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-8511: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. -> B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. 135011 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. S -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. 9331=1M I We cannot cover all specific applications or anticipate all requirements. ENSINEMINS & MMVMCTURINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:1) • 12/08/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0206 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-8 , FSP-851, FSP851R* and FSP-8511 photoelectric type smoke detectors. Models F - and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-7511, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air • velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to verify correct listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division f SYSTOW S SENSOR ..• B200S/B200S.LF) V Intelligent Sounder Bases HE System Sensor B2005 series sounder bases set a 200S:1f B200S new standard for performance, installation ease, and aesthetics. B200S Series Features Addressability for maximum configuration flexibility Two volume levels (75 or 85 dBA) Multiple event-driven tone outputs 5 • Supports Continuous, ANSI Temporal 3, ANSI Temporal 4, and March Time tones Custom tone capability with some FACP models Ability to synchronize with other System Sensor notification devices UL 268 and UL 464 compliant Pre-wire mounting plate fits various junction box sizes Mechanical locking feature prevents removal of attached sensor head Additional terminal connections on Canadian model (B200SA) enable silence feature 520 Hz +1- 10% square wave tone (B200S-LF) The B200S sounder base series is designed for new and existing dwelling unit applications. It offers maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The sounder base "listens in" to the communication between the attached sensor head and the fire alarm control panel (FACP) to adopt the same address as the detector, but as a unique device type on the loop. The FACP can then use that address to command an individual sounder - or a group of sounders - to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. In addition, some FACPs will enable custom tone patterns.t The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal - along with other System Sensor horns, horn strobes, and chimes - when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B200S series offers several key advantages. The sounder base employs a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. The housing also locks with the mounting plate using two retaining screws, for added tamper resistance. The 8200S-LF low frequency sounder base is designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to awaken sleeping occupants, even those with mild to severe hearing loss. tRefer to the appropriate FACP manual for more information. Agency Listings 0 & -.4~ 0 LISTED APPROVED SOIl 3035027 82005 7135-1653:0213 8200S.LF: 7300-1653:0238 Base Diameter 6.875"(17.46 cm) Base Height 2.0-(5.08 cm) less sensor Shipping Weight B200S: 0.50 lb. (227 gm); B200S-LF: 0.60 lb. (272 gm) Operating Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Operating Humidity Range 10% to 93% relative humidity (non-condensing) External Supply Voltage 16 to 33 VDC (VRNR) External Supply Standby Current 500 pA maximum Alarm Current 35 mA maximum at high-volume setting; 15 mA maximum at low-volume setting SLC Operatinqyoltage 15 to 32 VDC External Supply Voltage 16 to 33 VDC (VRNR) External Supply Standby Current 550 pA maximum Alarm Current High volume setting: 70 mA maximum @ 33.0 VDC 90 mA maximum @ 24.0 VDC 140 mA maximum @16.0 VDC Low volume setting: 15 mA maximum @33.0 VDC 20 mA maximum @ 24.0 VDC 25 mA maximum @ 16.0 VDC SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 pA maximum (base only, refer to applicable sensor specification) High Volume Greater than 85 dBA minimum - measured in a UL reverberant room at 10 ft. 24 Volts (in continuous tone) Low Volume Greater than 75 dBA minimum - measured in a UL reverberant room at 10 ft. 24 Volts (in continuous tone) S SYSTEM Ohio Avenue • St. Charles, IL 60174 02015 System Sensor Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change wctmut notice. Visa systemsensoccmrr SENSOR for current product information, including the latest version at this data sheet. www.systemsensor.com SPDS53602 • 02/15 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0238 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models B200S-LF and 8200SR-LF Low Frequency Intelligent Sounder Bases. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 16-33 VDCNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as low frequency intelligent sounder bases for use with listee's compatible separately listed detectors. These units can generate a low frequency alarm signal for sleeping areas in accordance with NFPA 72. Refer to listee's Installation Instruction Manual for details. 11-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not 'RVI an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to verify correct listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 200 Series Mounting Base Options System Sensor mounting bases and kits provide a variety of installation options for detectors in any application. Features Bases enable quick and secure detector plug-in SEMS screws provide easy wiring connection Support for 12-24 AWG (14-24 for B224RB and B224B1) provides S installation flexibility Multiple accessory options provide mounting flexibility Sounder bases are compliant with UL 464 and UL 864 Agency Listings Model Listings —r B501 B21OLP UL, ULQ FM, CSFM UL, ULC, FM, CSFM B200S UL, ULC, FM S B200SR UL, ULC, CSFM B224RB UL, ULC, CSFM B224B1 UL, ULC, FM, CSFM For ULC-listed products, add "Ato the model number (e.g., B501 A) To meet local code and application requirements, System Sensor offers relay, isolator, and sounder base options for 200 Series detectors. Relay bases provide one form C contact relay for control of auxiliary functions, such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in a combination temporal 3 and continuous tone model or an addressable model (13200S) that can be activated by the fire alarm control panel based on the event. 200 Series Bases provide a variety of mounting options to meet your installation challenges. Bases come in flanged or flangless versions for mounting to a variety of junction boxes. See the 200 Series Junction Box Selection Guide on the next page for junction box options. Surface mounting boxes are also available. Consult your fire alarm control panel manufacturer for compatibility with the addressable model of the sounder base. Specifications, 200 Series Bases Diameter B501: 4.1° (104mm); B21OLP, B224RB, B224B1: 6.1(155 mm); B200SR, B200S: 6.875" (175 mm) Wire Gauge B224B1, B224R8: 24 to 14 AWG; B200SR, B200S: 24 to 12 AWG Temperature Range 32°F to 120°F (0°C to 49°C); B501, B21OLP: -4°F to 150°F (-20°C to 66°C) Humidity Range 10% to 93% RH non-condensing Operating Voltage 15 to 32 VDC (powered by SLC) External Supply Voltage 16 to 33 VDC (VFWR) Standby Ratings <500 pA maximum @24 VDC Standby Current 500 uA max. Set Time (132241113 only) Short Delay: 55 to 90 msec Long Delay: 6 to 9 sec ResetTirne (132241113 only) 20 msec max. Relay Characteristics 2 coil latching relay Sound Output Greater than 90 dBA measured in anechoic (B224RB only) 1 Form C contact room at 10 feet, 24 volts. 85 dBA minimum in UL ULJCSA Rating: reverberant room 0.9 A @ 125 VAC Alarm Current 35 mA max. 0.9 A @ 110 VDC 3A@3OVDC 200 Series Junction Box Selection Guide Single 3.5" 4" 4" 4" 50 60 70 75 Model Gang Octagonal Octagonal Square Square* mm mm mm mm BS01 No Yes No No Yes Yes Yes Yes No B21OLP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes Yes No Yes Yes Yes B224B1 No Yes Yes Yes Yes No Yes Yes Yes B200SPJB200S Yes Yes Yes Yes Yes No No Yes No with 3.0 mud ring Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information, 200 Series Bases B200S Addressable Sounder Base ' Product Overview 8501'° 4"Flangeless Mounting Base When used with compatible fire alarm control panels, the B200S B501 BP* 4" Flangeless Mounting Base Bulk Pack sounder base provides unmatched flexibility to configure the B210LP 6" Flanged Mounting Base output to various events. When combined with System Sensor B210LPBP 6" Flanged Mounting Base Bulk Pack SpectrAlert Advance notification appliances, the B200S can serve B200SR* Standard Sounder Base (Compatible with B501 BH Series) as a component of the general evacuation signaling, improving B200S* Intelligent Addressable Sounder Base aesthetics and reducing system costs. B224RB Relay Base B224Bl Isolator Base Features: 200 Series Accessories . Simple addressing scheme - base adopts the same address as SMB600 Surface Mounting Kit (flanged) attached sensor F110 Accessory Flange Ring for 6" Base f. ckn, Dir,,, , D,-I. Synchronizable with SpectrAlert Advance notification appliances !LLLJJL)I y I CI ILflhIIILM U UUJCLJUIP. CLI', F21 0 Accessory New Smaller Flange Ring for 611 Base Four standard tone patterns at two selectable volumes RA100Z* Remote LED Annunciator Custom tone capability M02-04-01 Detectorlest Magnet Support forTemporal-4 CO annunciation M02-09-00 Test Magnet with Telescoping Handle XR2B Detector Removal Tool (155-1 27-000 included) XP-4 Extension Pole for XR2B (5 to 15 ft.) T55-127-000 Detector Removal Head BCK-200B Black Detector Kit WCK-200B White Detector Kit Add "A"to model number for ULC-listed product (e.g., 8501 A) 02011 System Sensor. IVa5TE7P1 3825 Ohio Avenue. St. Charles, IL 60174 ct to change Without mi Visit systernsensoccom for .SIJ5'OR° Phone: 800-SENSOR2. Fax: 630-377-6495 current product information including the latest version of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7300-1653:0109 Page 1 of I CATEGORY 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, 1340213, B404B, B404BT, B406B, 13501, B501 B, 14506587-002, B501 131-1, 135 , B110LP, BIIORLP, 13IIORLP750, 13112LP, 13II4LP, B1I4LPBT, Bil P ~B21OLPectorbases. Refer to listee's data sheet for detailed product description and siderations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 S 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM S $ SENSOR Intelligent Non-Relay Photoelectric Duct Smoke Detector The InnovairFIef Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features The InnovairFIex DNR intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct Photoelectric, integrated low-flow technology smoke detector feature a pivoting housing that fits both square and (detector head sold separately) rectangular footprints capable of mounting to a round or Air velocity rating from 100 ft/min to 4000ft1min (0.5m/s to 20.32m/sec) rectangular duct. Versatile mounting options: square or rectangular configuration DNRW duct smoke detector, with its NEMA 4 rating, is listed as a watertight enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). An improved cover design isolates the sensor head from the low- flow feature for simple maintenance. A cover tamper feature was added to indicate a trouble signal for a removed or improperly installed sensor cover.The InnovairFIex housing provides a 1/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of relay module. The InnovairFIex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. WARNING: Duct smoke detectors have specific limitations. • Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required New Cover tamper signal Increased wiring space with a newly added 1/4-inch conduit knockout Available space within housing to accommodate mounting of relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires corn line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV Resistant, UL listed housing and cover material (DNRW only) Agency Listings DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, S LISTED 2911 APPROVED 3029700 MSFM approved 3242-1653:209/210 2125 NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector application information. InnovairFiex Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex° DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA4 Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100ft/min to 4000 ft/mm (0.5 rn/sec to 2032 m/sec). The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS451 KEY/RTS15 1 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular) 14.38 in (37 cm) Length; Sin (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square) 7.75 in (19.7cm) Length; 9 in (22.9cm) Width; 2.5 in (6.35cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA4 (DNRW only) Operating Temperature Range: —4°F to 158°F (-20°C to 70°C) Storage Temperature Range: —22°F to 1S8°F (-30°C to 70°C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 20.32 m/s) DCOlL (if included): 17.5— 26.4 VDC, 95 mA max j. Please see detector head installation manual for electrical spccihcations Device Standby Alarm RA400Z/RA100Z OmA 12mAMax. RTS451/RTS451KEY 0 m 12 m Max. RTS151/RTS151KEY S Installing the InnovairFiex Sampling Tube The InnovairFiex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). _l 2ND DETECTOR IN LOOP Wiring for Intelligent Non-Relay Duct Smoke Detector . System wiring diagram for DNR: I I '----1 --I I I -----I UL/FM LISTED 1ST CONTROL DETECTOR PANEL IN LOOP DNR to RA400Z/RA100Z: + RA - RA400Z/RA1 - RA - COMM. LINE I REMOTE ALARM LED OPTION 1 PER UNIT I DNR to RTS4S1/RTS4S1KEY/RTS151fRTS151KEY with "R" Remote Test Capable Detector Head Option: TEST COIL + TEST COIL— COMM+ OUT (CONV ONLY) + COMM - RAIRTS— RA+ RTS+ RTS451/RTS451 KEY RTS151/RTS151KEY :JUMPER 2 L -[ 4 ---------- 5 DNR to RT5451/R15451 KEY/RTS151/RTS151 KEY with DCOIL Option*: TEST COIL+ TEST COIL— XTERNAL SUPPLY COMM + OUT (CONV ONLY) + R1S451/RTS451 KEY COMM- J RTS151/RTS151KEY REMOTE TEST STATION RA/RTS - LED OPTION RA+ 1 PER UNIT RTS + TEST COIL OPTION I PER UNIT 95mA CURRENT DRAW *Important Notes -The use of either R1S451/RTS151 or RTS451 KEY/RTS151 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. -The RTS451/RTS451 KEY/RTS151/RTS151KEY test coil circuit requires an external 24VDC power supply which must be UL listed. AOSO422003 DCOIL Remote test coil required with RT5451/RT545 1 KEY/RTS 15 1 /RTS 151 KEY DST1 Metal sampling tube duct width up to 1 ft (03m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft (12 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft (24 to 3.7 m) DI-14000E-1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 ft (0.3m) M02-04-00 Test magnet P48-21-GO End cap for metal sampling tubes RA400Z/RA100Z Remote annunciator alarm LED RTS451/RTS15 1 Remote test station RTS45 1 KEY/RTS15 1 KEY Remote test station with key lock Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. LV RTS151 UL S2522 RTS1 51 KEY UL S2522 RA100Z UL S2522 S Ordering Information I DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories (D201 0 System Sen5o, SVSTEM 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications subject to change without nofice. Visit systermsensorcorn for Phone: 800-SENSOR2. Fax: 630-377-6495 41 sheet. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE I' LISTING No. 3242-1653:0209 Page 1 of I CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VI ir.Kireyevhoneywell.com DESIGN: M dels DNR, DNR , DNRHS and DNRECL* analog photoelectric duct smoke detector ho s. The u consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. S Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM S $ SENSOR® C01224 Carbon Monoxide Detector System Sensor's CO 1224 provides early warning when its electrochemical sensing technology accurately measures carbon monoxide levels in the air. Carbon monoxide is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels, such as wood, gasoline, S charcoal and oil, are burned with insufficient air, The majority of residential and commercial fatalities caused from these fuels come from heating systems, power tools and charcoal grills. If carbon monoxide is detected, the C01224 will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. Features Full compliance with UL 2075 A code required trouble relay Wiring supervision with SEMS terminals A six-year end-of-life timer 12/24 VDC A current draw of 20mA in standby and 40mA in alarm Versatile mounting for wall and ceiling Electrochemical sensing technology The C01 224 is specifically designed for system operation. This means the detector is fully listed to UL 2075, offering a code required trouble relay, which sends a sensor failure or end-of-life signal to the control panel and the central station, as well as SEMS-type terminal Philips-head screws, which provide a quicker and more positive wiring connection and code required wiring supervision. Also, the C01224 offers a low current draw, allowing more detectors to be connected to the panel without having to purchase a more expensive panel or an extra power supply. Because the C01224 is a 12/24VDC detector, it will operate on most industry security or fire alarm control panels. Agency Listings ®:;:IMEA LISTED approved 2075 5276.1653:194 45406'S S Specifications Carbon monoxide detector shall be a System Sensor model number COI 224, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector's base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Size Length: 5.1", Width: 3.3", Height: 1.3" Approximate Weight 7 oz Operating Temperature Range 0° - 40°C (32° - 104°F) Operating Humidity Range 22-90% RH InputTerminals 14-22 AWG Mounting Single-gang back box; surface mount to wall or ceiling ration Modes Normal Blink 1 - (standby) per minute - Blink in Sound in Alarm - temp4 temp pattern pattern Information Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes. Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the sensor inside the detector has reached the end of its useful life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. S C01224 12/24 volt, 4-wire system-monitored carbon monoxide detector S 5'VC7T'AC'11I' ©2007 System Sensor. \. 1 N 3825 Ohio Avenue St. Charles, IL 601 74 Product rpeoficotiorosubject to change uithout notice. Visit systerrrser,sor.coru for SEiJ5'OAR Phone: 800-SENSOR2 Fax: 630-377-6495 oftfrodota sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 5278-1653:0219 Page 1 of I CATEGORY: 5278 -- CARBON MONOXIDE DETECTORS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models C01224, C01224T, and C0I224TR Carbon Monoxide detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 10-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes, NFPA 720, and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee;s name, Model number, electrical rating and UL label. APPROVAL: Listed as Carbon Monoxide detectors for use with separately listed fire alarm control units. NOTE: Carbon Monoxide detectors are not intended/suitable for fire and smoke detection. 12-06-10 bh TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S CP*i) SCRL Architect/Engineer Specifications GENERAL L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 1/8 inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall termi- nate at the universal mounting plate. Also, L-Series products, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regu- lated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95,115, 150, and 177. STROBE The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective ser- vice. The strobe shall be wired as a primary-signaling notifica- tion appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. HORN STROBE COMBINATION DN-60938:A indoor Selectable-Output Strobes and Horn Strobes forD p N OTI F I E R eiIing Applications by Honeywell S General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthet- ics. The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring conti- nuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances, flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non- coded power supply. S DN-60938:A • 2/3/2017 - Page 1 of 4 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective . service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8 inch back box. The module shall also con- trol two Style V (class B) circuits or one Style Z (class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity Range: 10 to 93% non-condensing Strobe Flash Rate: 1 flash per second Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 Aerating Voltage Range2 8 to 17.5V (12V nominal) or 6 to33V(24Vnonunal) Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal) Input terminal wire gauge: 12 to 18 AWG Ceiling-Mount Dimensions (including lens): 6.8 diame- ter 2.5° high (173 mm diameter 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9° diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: S 1. Full Wave Rectified (FWR) voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Dl UL MAX. STROBE Candela 8 15 30 75 95 115 150 177 [1 *This data represent current draw will vary depending upon coding selected. S Page 2 of 4— DN-60938:A • 2/3/2017 UL MAx. CHIME/STROBE CURRENT DRAW Candela 8 VDC 15 EM Temp Hi 103 1 EM Temp Low 96 1 EM Cont Hi 106 1 EM Cont Low 95 1 3.1K Temp Hi 111 1 3.lK Temp Low 103 1 3.1K Cont Hi 111 1 3.lK Cont Low 103 1 HORN AND HORN STROBE OUTPUT (DBA) Switch Position Sound Pattern dB 8-17.5 Volts DC 1 Temporal High 84 2 Temporal Low 75 3 Non-Temporal High 85 4 Non-Temporal Low 76 5 3.1 KHz Temporal High 83 6 3.1 KHz Temporal Low 76 7 3.1 KHz Non-Temporal High 84 8 3.1 KHz Non-Temporal Low 77 Candela I6VFWR 15 [ 30 75 95 115 150 177 EM Temp Hi 107 135 179 198 223 254 286 EM Temp Low 78 101 151 172 199 229 262 EM Cont Hi 107 135 179 198 223 254 286 EMContLow 78 101 151 172 199 229 262 3.1K Temp Hi 108 135 179 200 225 255 289 3.lK Temp Low 79 101 150 171 196 229 260 3.1K Cont Hi 108 135 179 200 225 255 289 3.lK Cont Low 79 101 150 171 196 229 260 Horn Strobe Tones and undOutptData S DN-60938:A • 2/3/2017 - Page 3 of 4 Product Drawings: L-Series Dimensions 2.47 1.37 2.50 Horn Strobes (Ceiling) Surface Mount Back Box (Ceiling) Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULJULC-Listed - S401 1 Ceiling horn strobes - S5512 Ceiling strobes - S5512 ALERT strobes with clear lenses FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. CEILING HORN STROBES WL", PC2RL. 2-Wire, HiTSVob(Whit)Red). CEILING STROBES SCWLSCRL 1Strobe (Ite Red) SCWL-CLR-ALERT. Strobe, ALERT (White). ACCESSORIES TR-2W, TR-2. Universal Wall Trim Ring (White, Red). SBBCWL, SBBCRL. Ceiling Surface Mount Back Box (White, Red). NOTIFIER® and SpectrAlert® are registered trademarks and Sync.CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 1111313=1=1 U .1 We cannot cover all specific applications or anticipate all requirements. E11116ERINS & MNUFAC1UUNC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-60938:A • 213/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL CHRL Chimes; P2 R , P2WL, Y2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobe PC2RL and PC2WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt i-v This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60918:A Indoor Selectable-Output __ NOTI Fl ER Horns, Strobes, and Horn __ p )Strobes for Wall Apphcat.onsj by Honeywell ol General The L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower cur- rent draws and modern aesthetics. With white and red plastic housings, standard and small footprint devices, and plain, FIRE-printed devices, L-Series can meet virtually any applica- tion requirement. The L-Series product line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features Updated modern aesthetics. Small profile devices for Horns and Horn Strobes. Plug-in design with minimal intrusion into the back box. Tamper-resistant construction. Automatic selection of 12- or 24-volt operation at 15 and 30 candela. Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185. Horn rated at 88+ dBA at 16 volts. Rotary switch for horn tone and two volume selections. Universal mounting plate for all standard and all compact wall units. Mounting plate shorting spring checks wiring continuity. before device installation. Electrically Compatible with legacy SpectrAlert® and SpectrAlert Advance devices. Compatible with MDL3 sync module. Listed for wall mounting only. Architectural/Engineering Specifications General: L-Series standard horns, strobes, and horn strobes shall mount to a standard 2' x 4 x 1/8" back box, 4 x 4' x 11/2' back box, 4' octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4" x 1/' back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard-size models and a separate universal mounting plate shall be used for mounting compact wall models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal P2RL im. F F I R P2GWL SGWL :au 12 or 24 volts. When used with the Sync.Circuit Module, 12- volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unaltered power supply. Strobes and horn strobes shall have field-select- able candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe. The strobe shall be a L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appli- ance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. S DN-60918:A • 2/3/2017 - Page 1 of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visi- ble signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (contin- uous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module. The module shall be a Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/6 x 411/° x 21/8 back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS Standard Operating Temperature: 32°F to 120°F (0°C to 49°C). Humidity Range: 10 to 93% non-condensing. Strobe Flash Rate: 1 flash per second. Nominal Voltage: Regulated 12 DC or regulated 24 DC! FWR1 (full wave rectified). 8 to 17.5 V (12 V nominal) or to 33V(?4Vnonilnál)3 Operating Voltage Range: MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) Input Terminal Wire Gauge: 12 to 18 AWG. Wall-Mount Dimensions (including lens): 5.6° L x 4.7 W x 1.25° D (143 mm Lx 119 mm W x 32 mm D). Compact Wall-Mount Dimensions (including lens): 5.26" Lx 3.46" W x 1.93" D (133 mm Lx 88 mm W x 49 mm D). Horn Dimensions: 5.6° Lx 4.7W x 1.25" D (143 mm Lx 119 mm W 32 mm D). Compact Horn Dimensions: 5.25" L x 3.45" W x 1.25" 0 (133mm Lx 88mm W x 32mm D). Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time- varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. L-Series Drawings Compact Horn k-3.46 1.25 .27 L N 0 :!!hIP,I Compact Combo Horn Combo 4.70 5.67 - 3.46 5.27 -. Page 2 of 4— DN-60918:A • 2/3/2017 Sound Pattern dB 8-17.è_ Volts( Voltsl DC( tD) FWR Temporal High 39 54 Temporal Low 28 ( 54 Non-Temporal High 43 ( () 54 Non-Temporal Low 29 ( () 54 3.1 KHz Temporal High 39 ( j) 54 3.1 KHz Temporal Low 29 ( 32 54 3.1 KHz Non-Temporal High 42 ( ) 54 3.1 KHz Non-Temporal Low 28 ( ) 54 Coded High 43 ( 54 3.1 KHz Coded High 42 rl L41 54 S UL Current Draw Data L MAX. CURRENT 8-17.5 Volt( DC Input :\ DC Input: 16-33 Volts FWR Input: 16 FWR 15 cd cd 15 cd 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd 15 d 30 cd 75 cd 95 cd 110 cd 135 cd 185 cd EM Temp Hi 98 158 54 74 121 142 162 196 245 3 107 156 177 198 234 287 EM Temp Low 93 154 44 65 111 133 157 184 235 8 91 145 165 185 223 271 EM Cont Hi 106 166 73 94 139 160 182 211 262 11 135 185 207 230 264 316 EM Cont Low 93 156 51 71 119 139 162 190 239 9 104 157 175 197 235 283 3.1K Temp Hi 93 15 53 73 119 140 164 190 242 1 105 155 177 196 234 284 3.lKTemp Low 91 154 45 66 112 133 160 185 235 8 90 145 166 186 222 276 3.1K Cont Hi 99 16 69 90 135 157 175 208 261 04 131 177 204 230 264 326 3.1k Cont Low 93 15 52 72 119 138 162 192 242 7 102 156 177 199 234 1 291 HORN TONES AND SOUND OUTPUT DATA: HORN AND HORN STROBE OUTPUT (DBA) Pos. Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR 1 Temporal High 84 89 89 2 ITemporal Low 75 83 83 3 Ion-Temporal High 85 90 90 4 Ion-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7t 3.1 KHz Non-Temporal High 84 89 89 8t 3.1 KHz Non-Temporal Low 77 83 83 9t oded High 85 90 90 10 3.1 KHz Coded High 84 89 89 DN-60918:A • 2/3/2017 - Page 3 of 4 S Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC-Listed - S4011 Wall Horn Strobes - S5512 Wall Strobes - S5512 Wall Horns FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. WALL HORN STROBES P2WL(A), P2RL(A). 2-Wire, Horn Strobe (White, Red). P2GWL(A), P2GRL(A). 2-Wire, Compact Horn Strobe (White, Red). P2WL(A)-P, P2RL(A)-P 2-Wire, Horn Strobe, Plain (White, Red). P2WL-SP, P2RL-SP 2-Wire, Horn Strobe, FUEGO (White, Red). WALL STROBES SWL(A), SRL(A). Strobe, Red (White, Red). SGWL(A), SGRL(A). Compact Strobe (White, Red). SWL(A)-P, SRL(A)-P. Strobe, Plain (White, Red). SRL-SP. Strobe, FUEGO (Red). S SWL-CLR-ALERT. Strobe, ALERT (White). SWL-ALERT. Strobe, Wall, Amber Lens, Alert (White). HORNS HWL(A), HRL(A). Horn (White, Red). HGWL(A), HGRL(A). Compact Horn (White, Red). ACCESSORIES TR-21111, TR-2. Universal Wall Trim Ring (White, Red). SBBWL, SBBRL. Wall Surface Mount Back Box (White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White, Red). Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. ULC-listed "A" models have FIRE/FEU marking on cover. NOTIFIER® and SpectrAlert® are registered trademarks and Sync.CircuitTM is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 10 ISO 9001 We try to keep our product information up-to-date and accurate. VTTT We cannot cover all specific applications or anticipate all requirements. ENSINEERING & MUFACTURINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-60918:A • 2/3/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCR3Id Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC S Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrA lert Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. [torr+r Sy9 t e no 'S ,.e n s 0 r Features Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30,75,95,110,115,135,150,177, and 185 Plug-in design with minimal intrusion into the back box -Tamper-resistant construction Universal mounting plate for wall- and ceiling mount units Mounting plate shorting spring tests wiring continuity before devices are installed Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Rated from —40°F to 151°F Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Agency Listings The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12-or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SIGNALING LISTED 54011 (chimes, horn strobe,, horns) APPROVED 53593 (outdoor and alert strobes) 3023572 0 MEA 730& 1653:187 (outdoor strobes) approved 7125-1653:188 (horn strobes, chime strobes) MEA452-05-E 7135-1653:189 (horn,, chimes) SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model -listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The horn strobe shall be suitable for use in wet environments. Operating Temperature —40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) • 68" diameter x 2.5" high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6'L x 4.7W x 2.5"D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6"L x4.7"Wx 1.3"D(142 mm Lx 119 mmWx 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7" Lx 5.1 "W x 2.0"D (145 mm Lx 130 mm W x 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC) 7.1 "diameter x 2.0" high (180 mm diameter x 51 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AOS-0456'002 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d8 DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 -Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela 42 ratings must be reduced in accordance with this table. 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 tsettings 7, 8, and 9 are not available on 2-wire horn strobe AOS0456-002 ____________________________ Listed Candela . . .• .- Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 SpectrAlert Advance Dimensions _ Wall-mount horn strobes Wall weatherproof back box 2.5 ''- I Ceiling-mount horn strobes 7 1- ia Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor P2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor P2WHKt 2-Wire Horn Strobe, High cd, White, Outdoor P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor P2RHK-1 20 2-Wire Horn Strobe, High cd, Red, Outdoor, 120V Wall Strobes SRKt Strobe, Standard cd, Red, Outdoor SRHKt SWKt Strobe, High cd, Red, Outdoor Strobe, Standard cd, White, Outdoor SWHKt Strobe, High cd, White, Outdoor ) Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor PC2WHK 2-Wire, Horn Strobe High cd, White, Outdoor PC4WK 4-Wire, Horn Strobe, Standard cd, White, Outdoor PC4WHK 4-Wire, Horn Strobe, High cd, White, Outdoor Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCWK Strobe, Standard cd, White, Outdoor SCWHK Strobe, High cd, White, Outdoor Horns HRK Horn, Red, Outdoor Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and \NTPW. "Standard cdrefers to strobes that include 1515/75,30,75,95, 110, and 115 candela settings."High cdrefers to strobes that include 135, 150,177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. S Th SYSTEM SENSOR ©2009 System sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications subject moohangemmhootnommoe.wmwemmensocomnfor Phone: 800-SENSOR2. Fax: 630-377-6495 ourreempmodsmm,nfommwrsrmdwgthelatestvernonofthndatasheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywelI.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be n icating indoor or outdoor use, or may be followed by suffix "P' for followed by the su Weerrir plain housing with ng. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division