Loading...
HomeMy WebLinkAbout2560 FARADAY AVE; ; FPC2021-0055; Permit'i : ACI ]r:I Cr'cityr of Carlsbad 'k (I11ft@ Print Date: 04/20/2022 Permit No: FPC2021-0055 Job Address: 2560 FARADAY AVE. CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Special Equipment Parcel #: 2091200100 Track #: Applied: 04/15/2021 Valuation: $0.00 Lot #: Issued: 06/10/2021 Occupancy Group: Project #: Finaled Close Out: 04/20/2022 #01 Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: OAKMONT - EMERGENCY RESPONDER RADIO COVERAGE FPContractor: CAL BUILDING SYSTEMS INC 3900 PROSPECT AVE, # B YORBA LINDA, CA 92886-1745 (714) 993-9650 FEE AMOUNT FIRE Plan Resub (3rd&Subsequent Submittal/hr) $204.00 FIRE Special Equipment (Ovens, Dust, Battery) $417.00 Total Fees: $621.00 Total Payments To Date: $621.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov ERRCS Technical Booklet Fire/Life Safety Access Controt CCTV Phone Systems Intercom SITE ADDRESS: 2560 FARADAY AVE. CARLSBAD, CA 92008 BDA LOCATION: 1ST FLOOR MPOE BDA MODEL & SN#: COMBA RX7W22-78B33348 SN# N/A CUSTOMER CONTACT: OAKMONT SENIOR LIVING CONTRACTOR CONTACT: JOHN CALVIN CAL BUILDING SYSTEMS (951) 640-9163 BILL OF MATERIALS IManufacturer CommScope Model LMAX-O-CPUSEi Cell-Max Omnidirectional in-Building Antenna System - 698-960 MHz and 1710-2700 MHz - N-Female 29 Laud 0612 06-896 MHz 12-Element 11 dB Gold Anodized Vagi Antenna N/f 1 CommScope L4RP-50 1'2" Air Dielectric, Plenum Rated (CATVP), HL Series - 50-ohm 2,000 ft Times Microwave Systems MR-240-3.28ft 50 Ohm - 3.28 ft LMR-240 jumper Cable N-male to N-male 30 Times Microwave Systems MR-240-3.28ft SO Ohm -3.28 ft LMR-240 Jumper Cable N-female to N-female 35 CommScope F4-50A 50 ohms - 1/2" coaxial cable - foam dielectric 200 ft CommScope L4PNM N for LDF4-SOA, Low Density Foam Dielectric Cable 75 Comba 7W22-78AA3348 X7W22-78B33348 RX78V1B3348UL* Class B Dual Band 700/800 Amplifier 48VDC 1 Comba C-R06-ON300C(XH) N.Ameri ca) (Passive) 6 dB Directional Coupler, 698-2700 MHz, N-Female Connectors 12 Comba C-R10-0N300C(XH) N.Ameri ca) (Passive) 10 dB Directional Coupler, 698-2700 MHz, N-Female Connectors 7 Comba C-R15-0N300C(XH) N.America)(Passive) 15 dB Directional Coupler, 698-2700 MHz, N-Female Connectors 5 Comba PS-E2-ON50M(XH) N.America)(Passive) 2-Way Wideband In-line Wilkinson Power Splitter 4 Newmar E-48V-480W-55AH-UL Newmar NEMA-4 UL Certified, NFPA compliant battery back up power 1 PolyPhaser XZ-+36NFNF-A 400-1200 MHz. DC PASS COAX PROTECTION, NF TO NF 1 DAS Alert 1221-B Dedicated Annunciator and Monitoring Panel 1 Rohn ROHFRM125 60" x 1.25" OD Mast Fiat Roof Non-Penetrating Mount 1 Rohn ROHFRMMAT Mat Kit for FRM Mounts (1 per) 42-1/2'x 36" x 1/8" Thick 1 CommScope 1088-1 IStandard Grounding Kit for 1/2 in corrugated coaxial cable and elliptical waveguide180 and 220 1 CriticalPointTM Public Safety Bi-Directional Amplifier C@Mba RX-7W22 Class B PS 700/800MHz BDA Features Digital/programmable utilizing FPGA Supports public safety 700/800MHz in single band or dual band version Supports P25 P1/P2 digital and conventional analog communications simultaneously Supports FirstNetT11 LIE band 14 Single band versions include license to switch from original band to alternate band Single band can be upgraded to dual band via license key Each band supports up to 3 wide band filters 2W output power for each band Built-in mandatory isolation test to prevent BDA oscillation Auto shutdown with alarm upon oscillation detection Web based GUI for intelligent configuration, SNMP supported NFPA compliant dry contact alarms, NEMA 4X enclosure FCC: PX8RX-7W22-B, IC: 11919A-RX7W22 UL 60950-1 & UL 60950-22 Compliant Specifications Electrical 700MHz 800MHz Frequency Range, Uplink MHz US: 788-805, CA: 798-806 US:806-817, CA:806-824 Frequency Range, Downlink MHz US: 758-775, CA: 768-776 US:851-862, CA:851-869 Filter Bandwidth MHz 0.2-10 0.2-10 Number of Filters 3 3 Total Output Power, Uplink dBm 27 Total Output Power, Downlink dBm 33 33 Maximum System Gain dB 90 90 Gain Adjustment Range (1dB step) dB 0-30 0-30 Pass Band Ripple, p-p dB 15 5 < 5 Uplink Noise Figure dB < 5 :5 5 System Group Delay Msec :~ 6.5 !~ 6.5 Out-of-Band Suppression dBc ~ 45 @ filter edge + 0.6MHz 2:60 filter edge + 1MHz 45 @ filter edge + 0.6MHz 2: 60 @ filter edge+ 1MHz Intermodulation dBm < -13 -13 Spurious 9kHz to 1GHz dBm FCC Compliance FCC Compliance 1GHz to 12.75GHz dBm Maximum RF Input Power without Damage dBm 10 10 Maximum RF Input Power without Overdrive dBm -20 -20 ALC Range dB 60 60 Input VSWR :5 1.5 1.5 Impedance 50 50 © 2017 Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of ordering. Pagel of 2 Specifications may differ depending on region and customers' requirements. Ds-control: 1-2-2 / 0119 Mechanical Dimensions, H x W x D in(mm) 20.9 x 15.4 x 8.3 (530 x 390 x 210) Weight (without bracket) lb(kg) 50.7 (23) Power Supply VAC 100-240/47-63Hz VDC -40---58 Power Consumption Single band W 80 Dual band W 100 Enclosure Cooling Convection RF Connectors N-Female Test Port SMA, -22dB Maximum Input for Dry Contact Port 24VDC, 1A / 11OVAC, 0.5A Operating Temperature °F(°C) i -27 to +140 (-33 to +60) Operating Humidity <— 95% Environmental Class NEMA 4X MTBF hr ~ 100,000 @77°F Note: Typical specifications at room temperature, Outline Drawing Part Numbers Product Type PN (AC Version) PN (DC Version) Class B (US) Single band 700MHz RX7W22-0713333AC RX7W22-07B33348 Single band 800MHz RX7W22-08B333AC RX7W22-08B33348 Dual band 700/800MHz RX7\N22-78B333AC RX7W22-78B33348 Class B (Canada) Single band 700MHz RX7W22-C7B333AC RX7W22-C7B33348 Single band 800MHz R1-7W22-C8B333AC RX7W22-C8B33348 Dual band 700/800MHz RX7W22-CFB:333AC RX7W22-CFB33348 License Dual Band (700/800MHz) License I RX7W22-L78B333 © 2017 Comba Telecom. All rights reserved Information contained in this document is subject to confirmation at time of orcering. Page 2 of 2 Specifications may differ depending on region and customers' requirements. DS-Control: 1-2-2/0119 Enclosure B 48V, 100AH Ell, 116 I Ell UL Certified Public Safety/BDA In-Building Coverage An integral part of an in-building solution for emergency response radio coverage is the backup power system. NFPA codes relating to the autonomous operation and monitoring of the BDA power is quite stringent. These back up power enclosures were engineered to meet every aspect of NFPA 1221 and provide integrators configuration flexibility and rapid delivery directly to site, batteries included. Features Certified to UL 924 (models with UL suffix) NFPA Compliant All Required monitoring alarms Batteries included Choose capacity to match system requirements NEMA-4 Enclosure Prewired with waterproof feed thru' s for easy on-site connections: Customization to meet local AHJ 's requirements Enclosure A 12, 24, & 48V DC, 18- 100AH Specifications Input: 115/230 VAC (factory wired for 120V AC) Outputs: DC: 12, 24 and 48V, with 120, 240 and 480 watt DC UPS AC: 11 OV at 96 watts - see reverse for detailed specifications Protections: Battery breaker, AC input breaker, NEMA enclosure, liquid tight cord grips NFPA 1221 Compliant Alarms (Form C, Dry Contact) AC fail Battery discharged to 30% of capacity Charger fail Batteries Included: maintenance free, valve regulated, sealed lead acid, 18, 55, and 100 AH capacity Enclosure Size including Mounting Flanges (H x W x D): 30" x 23" x 10.5" 25" x 24" x 24" T Usn IsmO Conforms to NFPA® UL Standard MEMBER 924 2018-2019 Enclosure A: NEMA-4, UL listed, welded aluminum with IP 65 battery vent and locking door, 4 each 1/2" knock-outs for cable entry on sides and bottom (16 total), IP-68 cable entries. Red powder coat wall mount. Enclosure B: NEMA-4, welded aluminum with IP 65 vent, pad lockable door handle, 8 each 1/2" knock-outs for cable entry (4 ea. on bottom left and right), IP-68 cable entries. Red powder coat wall mount, Output (Model Voltage PE-12V-120W-18AH-UL 12V DC PE-12V-120W-55AH-UL 12V DC PE-12V-120W-100AH-UL 12V DC PE-24V-240W-18AH-UL 24V DC PE-24V-240W-55AH-UL 24V DC PE-24V-240W- 100AH-UL 24V DC PE-48V-480W-18AH-UL 48V DC PE-48V-480W-55AH-UL 48V DC PE-48-480W-100AH 48V DC PE-1 I OV-1 Dow-i OOAH/24V 110V AC *See reverse for battery specifications DC UPS Batt. A/H System w/ Batt. Shipping Enclosure Power Watts Capacity' Wt. (Lbs.) Wt. (Lbs.) Size 18 18 49 89 A 55 55 75 115 A 60 100 111 151 A 36 18 63 103 A 110 55 114 154 A 120 100 186 226 A 72 18 90 130 A 200 55 190 230 A 480 100 371 411 B 96 100 191 231 A UL: Models ETL Listed to UL Standard 924 Power/na the Network HFPA Compliant Battery Back-Up Power Battery Specifications Max Max Electrolyte Content Continuous Continuous Model Amp/Hour Battery Quantity Load 12 Hour Load Pounds Gallons Rating 24 Hour Rating 12V DC PE12V120Wf18AHUL. ES17-12S 1 1.5A/18W .75A/9W 1.9 03 PE- 12V-120W--55AH-UL XP12-210FR 1 4.6A/55W 2.33A/28W 7.6 0.8 PE- 12V-120W-l100AH-UL PYL12V100FS 1 5A/60W 4.6A/55W 22.8 1.6 1 24-V DC ___________--____ _____ - PE-24V-240Wi1-18AH-UL ES17-12S 2 1.5A/36W .75A/18W 3.9 0.6 PE-24V-240W155AH-UL XP12-210FR 2 4.6A/11OW 2.33A/56W 15,2 1.6 PE-24V-240W11 -UL PYL12V100FS 2 5A/120W 4.6A/110W 45.7 3.2 48V DC PE.48V-480W}18AH-UL ES17-12S 4 1.5A/72W .75A/36W 7.7 1.3 PE-48V-480W--55AH-UL XP12-210FR 4 4A/192W 2.33A/112W 30.5 3.2 PE-48V-480W'I-lOOAH PYL12V100FS 4 8.5A/392W 4.6A/221W 91.3 6.3 Ic PE-110V-100WIf1OOAH/24V PYL12V100FS 4 N/A 96W 91.3 6.3 Based on 100% duty cycle. Back-up time increase if intermittent duty cycle loads applied. * Certified to UL 924 Standards Door Mounted Alarm Indicator Lights Alarm Contacts Typical Wiring Diagram Battery Disconnect AC Input Breaker Disconnect Breaker BDS-DIN-UPS-48- 10, DIN Pail DC UPS, 48V DC, 10 Amps 115V AC Jumper Manual Holder a(1 (((f[[(III/IIif (I 1111 I IU1IIr l"w Battery (-) Battery Jumpers x 3 Battery (+) Power/no the Network ALLiRPV5O AL4RPV_50, HELIAX® Plenum Rated Air Dielectric Coaxial Cable, corrugated aluminum, 1/2 in, off white PVC jacket This product is part of the CommScope Wired for Wireless® Solution Product Classification Brand HELIAX® Product Series AL4-50 Product Type Air coaxial cable Construction Materials Jacket Material PVC Dielectric Material PE spline Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Off-white Outer Conductor Material Corrugated aluminum Dimensions Nominal Size 1/2 in Cable Weight 014 lb/ft Diameter Over Jacket 15.748 mm I 0.620 in Inner Conductor OD 4.5720 mm I 0.1800 in Outer Conductor OD 14.046 mm I 0.553 in Electrical Specifications Cable Impedance 50 ohm ±2 ohm Capacitance 75.5 pF/m I 23.0 pF/ft dc Resistance, Inner Conductor 0.480 ohms/kft dc Resistance, Outer Conductor 0.480 ohms/kft dc Test Voltage 4000 V Inductance 0.190 JH/m 1 0.058 pH/ft Insulation Resistance 100000 Mohms.km Jacket Spark Test Voltage (rms) 5000 V Operating Frequency Band 1 - 6000 MHz Peak Power 40.0 kW Power Attenuation 2.325 Pulse Reflection 0.5% Velocity 88 % page 1 of 4 AL'+PPV-50 Environmental Specifications Installation Temperature Operating Temperature Storage Temperature General Specifications Ordering Note Mechanical Specifications Bending Moment Fire Retardancy Test Method Flat Plate Crush Strength Minimum Bend Radius, Multiple Bends Minimum Bend Radius, Single Bend Number of Bends, minimum Tensile Strength -5 °C to +60 °C (+23 °F to +140 °F) -20°C to +85 °C (-4°F to +185 °F) -20°C to +85°C (-4°F to +185 °F) CommScope® standard product (Global) 6.8 N-rn I 5.0 ft lb NFPA 262/CATVP/CMP 80.0 lb/in 127.00 mm 5.00 in 63.50 mm 2.50 in 15 79 kg I 1741b Note Performance Note Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C 68 °F Average Power, Ambient Temperature 40 °C 104 °F Average Power, Inner Conductor Temperature 100 °C 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 700-894 MHz 125 19.10 806-960 MHz ' 1.25 19.10 1700-2200 MHz 1.25 19.10 page 2 of 4 AL+PPV-5O Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.152 0.046 40.00 1 0.216 0.066 35.37 1.5 0.264 0.081 28.84 2 0.306 0.093 24.95 10 0.691 0.211 11.04 20 0.985 0.3 7.75 30 1.213 0.37 6.29 50 1.581 0.482 4.83 85 2.087 0.636 3.66 88 2.126 0.648 3.59 100 2.274 0.693 3.35 108 2.368 0.722 3.22 150 2.821 0.86 2.70 174 3.054 0.931 2.50 200 3.292 1.003 2.32 204 3.327 1.014 2.29 300 4.104 1.251 1.86 400 4.808 1.466 1.59 450 5.134 1.565 1.49 460 5.197 1.584 1.47 460 5.197 1.584 1.47 500 5.445 1.659 1.40 512 5.517 1.682 1.38 600 6.032 1.839 1.26 700 6.583 2.007 1.16 800 7.105 2.166 1.07 824 7.227 2.203 1.06 894 7.574 2.308 1.01 960 7.892 2.405 0.97 1000 8.081 2.463 0.94 1218 9.068 2.764 0.84 1250 9.207 2.806 0.83 1500 10.256 3.126 0.74 1700 11.053 3.369 0.69 1794 11.416 3.48 0.67 1800 11.439 3.487 0.67 2000 12.192 3.716 0.63 2100 12.559 3.828 0.61 2200 12.92 3.938 0.59 2300 13.276 4.046 0.57 2500 13.975 4.259 0.55 2700 14.656 4.467 0.52 3000 15.649 4.77 0.49 3400 ., 16.928 5.159 0.45 3600 17.551 5.349 0.43 page 3 of 4 /L4RPV-5O 3700 17.859 5.443 0.43 3800 18.164 5.536 0.42 3900 18.467 5.628 0.41 4000 18.768 5.72 0.41 4100 19.066 5.811 0.40 4200 19.363 5.902 0.39 4300 19.658 5.991 0.39 4400 19.951 6.081 0.38 4500 20.241 6.169 0.38 4600 20.531 6.257 0.37 4700 20.818 6.345 0.37 4800 21.104 6.432 0.36 4900 21.388 6.519 0.36 5000 21.671 6.605 0.35 6000 24.42 7.443 0.31 * Values typical, guaranteed within 5% Regulatortj Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant ETL Certification CATVP/CMP ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system c(ETL)us Certification CATVP!CMP ®O 4 page 4 of 4 LDF'+-501\ TALLE You Connect the World. We Make it Easy.' LDF4501t,, HELIAX® Low Densitj Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket Product Classification Brand HELIAX® Product Series LDF4-50A Product Type Coaxial wireless cable Standards And Qualifications EN50575 CPR Cable EuroClass Fca Construction Materials Jacket Material PE Outer Conductor Material Corrugated copper Dielectric Material Foam PE Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Black Dimensions Nominal Size 1/2 in Cable Weight 0.15 lb/ft I 0.22 kg/m Diameter Over Dielectric 12.954 mm I 0.510 in Diameter Over Jacket 15.875 mm 0.625 in Inner Conductor OD 4.8260 mm 0.1900 in Outer Conductor OD 13.970 mm 0.550 in Electrical Specifications Cable Impedance 50 ohm ±1 ohm Capacitance 23.1 pP/ft I 75.8 pP/rn dc Resistance, Inner Conductor 0.450 ohms/kft 1 1.480 ohms/km dc Resistance, Outer Conductor 0.820 ohms/kft I 2.690 ohms/km dc Test Voltage 4000 V Inductance 0.190 pH/rn I 0.058 pH/ft Insulation Resistance 100000 Mohms.km Jacket Spark Test Voltage (rms) 8000 V Operating Frequency Band 1 - 8800 MHz Peak Power 40.0 kW page 1 of 4 October 11, 2018 LDFLi5OA Velocity Environmental Specifications Installation Temperature Operating Temperature Storage Temperature General Specifications Ordering Note Mechanical Specifications Bending Moment Flat Plate Crush Strength Minimum Bend Radius, Multiple Bends Minimum Bend Radius, Single Bend Number of Bends, minimum Number of Bends, typical Tensile Strength Note Performance Note rALLE You Connect the World. We Make It Easy.' 88% -40°C to +60°C (-40 OF to +140 °F) -55 °C to +85°C (-67 OF to +185 °F) -70 °C to +85 °C (-94°F to +185 °F) ComrnScope® standard product (Global) 3.8 N-rn I 2.8 ft lb 110.0 lb/in 2.0kg/mm 127.00 mm 5.00 in 50.80 mm 2.00 in 15 50 113 kg I 2501b Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C 68 OF Average Power, Ambient Temperature 40 °C 104 OF Average Power, Inner Conductor9emperature 100 °C 212 OF Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 680-800 MHz 1.13 24.30 800-960 MHz 1.13 24.30 1700-2200 MHz 1.13 24.30 2300-2700 MHz 1.13 24.30 page 2 of 4 LDFLE5OA rALLE You Connect the World. We Make it Easy. Attenuation Frequency (MHz) 0.5 1.5 2 10 20 30 50 85 88 100 108 150 174 200 204 300 400 450 500 512 600 700 800 824 894 960 1000 1218 1250 1500 1700 1794 1800 2000 2100 2200 2300 2500 2700 3000 3400 3700 4000 5000 Attenuation (dB/100 m) 0.149 0.211 0.259 0.299 0.672 0.954 1.172 1.521 1.995 2.031 2.169 2.256 2.673 2.887 3.103 3.135 3.835 4.462 4.749 5.021 5.085 5.533 6.009 6.456 6.56 6.855 7.124 7.284 8.11 8.226 9.093 9.744 10.039 10.058 10.666 10.961 11.251 11.535 12.09 12.627 13.407 14.401 15.118 15.815 18.01 Attenuation (dB/100 ft) 0.045 0.064 0.079 0.091 0.205 0.291 0.357 0.463 0.608 0.619 0.661 0.688 0.815 0.88 0.946 0.956 1.169 1.36 1.447 1.53 1.55 1.686 1.831 1.968 1.999 2.089 2.171 2.22 2.472 2.507 2.771 2.97 3.06 3.066 3.251 3.341 3.429 3.516 3.685 3.849 4.086 4.389 4.608 4.82 5.489 Average Power (kW) 40.00 36.11 29.46 25.50 11.35 7.99 6.51 5.02 3.82 3.76 3.52 3.38 2.85 2.64 2.46 2.43 1.99 1.71 1.61 1.52 1.50 1.38 1.27 1.18 1.16 1.07 1.05 0.94 0.93 0.84 0.78 0.76 0.76 0.72 0.70 0.68 0.66 0.63 0.60 0.57 0.53 0.50 0.48 0.42 page 3 of 4 October 11, 2018 LDF4-50A 1ALLE You Connect the World. We Make it Easy.* 6000 20.055 6.113 0.38 8000 23.826 7.262 0.32 8800 25.244 7.694 0.30 * Values typical, guaranteed within 5% Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant China RoHS Si/I 11364-2006 Below Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system CENELEC EN 50575 compliant, Declaration of Performance (DoP) available page 4 of 4 October 11, 2018 L-fTNM-PSA You Connect the World. We Make it Easy. lljpe N Male Positive StopTM for 112 in /L4RPV-50, LDF'-i.-50A, HL+RPV- 50 cable ( . This product is part of the CommScope Wired for Wireless® Solution Product Classification Brand HELIAX® I Positive StopTM Product Type Wireless and radiating connector General Specifications Interface N Male Body Style Straight Harmonized System (HS) Code 854420 (Coaxial cable and other coaxial electric conductors) Mounting Angle Straight Ordering Note CommScope® standard product (Global) Electrical Specifications Connector Impedance 50 ohm Operating Frequency Band 0 - 8800 MHz Cable Impedance 50 ohm 3rd Order IMD, typical -116 dBm @910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimum 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiveness -130 dB page 1 of 3 LLITNMP5A rALLE You Connect the World. We Make it Easy. Outline Drawing MAlES. TO MIL—STD--34, CPU mm) Mechanical Specifications Outer Contact Attachment Method Ring-flare Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Contact Plating Silver Attachment Durability 25 cycles Interface Durability 500 cycles Interface Durability Method IEC 61169-16:9.5 Connector Retention Tensile Force 890 N 1 200 lbf Connector Retention Torque 5.42 N-rn 48.00 in lb Insertion Force 66.72 N 15.00 lbf Insertion Force Method MIL-C-3901 2C-3.12, 4.6.9 Coupling Nut Proof Torque 4.52 N-rn 40.00 in lb Coupling Nut Retention Force 444.82 N I 100.00 lbf Coupling Nut Retention Force Method MIL-C-39012C-3,25, 4.6.22 Dimensions Nominal Size 1/2 in Diameter 22.35 mm I 0,88 in page 2 of 3 LLFTNMPSA 1ALLE You Connect the World. We Make it Easy. Length 76.70 mm 1 3.02 in Weight 94.71 g 1 0.21 lb Environmental Specifications Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F) Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F) Immersion Depth 1 m Immersion Test Mating Unmated Immersion Test Method IEC 60529:2001, lP68 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 60529:2001 , IP66 Moisture Resistance Test Method MIL-STD-202F, Method 106F Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition I Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-i, Low Temperature -55°C Vibration Test Method IEC 60068-2-6 Corrosion Test Method MIL-STD-1344A, Method 1001. 1, Test Condition A Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 45-1000 MHz 1.02 39.00 1010-2200 MHz 1.03 37.00 2210-3000 MHz 1.05 33.00 3010-4000 MHz 1.09 27.00 4010-6000 MHz 1.25 19.00 6010-8000 MHz 1.33 17.00 Requlatorlj Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption China RoHS Si/T 11364-2006 Above Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system * Footnotes Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05rifreq (GHz) (not applicable for elliptical waveguide) page 3 of 3 TrTIMES MICROWAVE SYSTEMS L9eDe Low Loss Co cos Coax ildeal for... Jumper Assemblies in Wireless Communications Systems Short Antenna Feeder runs (e.g. WLL, GPS, LMR, Mobile Antennas) Any application (e.g. WLL, GPS, LMR, WLAN, WISP, WiMax, SCADA, Mobile Antennas) requiring an easily routed, low loss RF cable LMR-240 Outdoor PE Black 54021 LMR-240-DB OutdoorN\/atertight PE Black 54090 LMR-240-FR Indoor/Outdoor Riser CMR FRPE Black 54029 LMR-240-FR-PVC Indoor/Outdoor Riser CMR FRPVC Black 54214 LMR-240-PVC General Purpose PVC Black 54140 LMR-240-PVC-W General Purpose PVC White 54202 LMR-240-MA Indoor & Mobile Antenna PVC Black 54046 Environmental Specnications Performance Property DF C. Installation Temperature Range -40/+185 -40/+85 Storage Temperature Range -94/+185 -70/+85 Operating Temperature Range -40/+185 -401+85 Bend Radius: installation in. (mm) 0.75 (19.1) Bend Radius: repeated in. (mm) 2.5 (63.5) Bending Moment ft-lb (N-m) 0.25 (0.34) Weight lb/ft (kg/rn) 0.034 (0.05) Tensile Strength lb (kg) 80 (36.3) Flat Plate Crush lb/in. (kg/mm) 20 (0.36) Inner Conductor Solid BC 0.056 (1.42) Dielectric Foam PE 0.150 (3.81) Outer Conductor Aluminum Tape 0.155 (3.94) Overall Braid Tinned Copper 0.178 (4.52) Jacket (see table) 0.240 (6.10) Electrical Specifications Performance Property Units us (metric)4- Velocity of Propagation 83 Dielectric Constant NA 1.42 Time Delay nS/ft (nS/m) 1.21 (397) Impedance ohms 50 Capacitance pF/ft (pF/m) 24.2 (79.4) Inductance uH/ft (uH/m) 0.060 (0.20) Shielding Effectiveness dB >90 DC Resistance Inner Conductor ohmsl1000ft (/km) 3.2 (10.5) Outer Conductor ohms/1000ft (/km) 3.89 (12.8) Voltage Withstand Volts DC . 1500 Jacket Spark Volts RMS 5000 Peak Power kW 5.6 18 (800) TMS-COAX • www.timesmicrowave.com 7rTIMES MICROWAVE SYSTEMS - Calculate Attenuation = (0.242080) . '.J FMHz + (0.000330). FMHz (interactive calculator available at http://www.timesmicrowave.com/cable_calculators) Attenuation: VSWR=1.0 Ambient = +25°C (77°F) Power: VSWR=1.0; Antient= +40°C; Inner Conductor = 10°C (212°F); Sea Level; dry air; atmospheric pressure; no solar loading (800) TMS-COAX • www.timesmicrowave.com 19 7rTIMES MICROWAVE SYSTEMS IL Rfl Or-2,60 FkerOlbge Low Loss Co cos Coz 2 - 4 3 / W / TC-240-FM-X EZ-240-NMH-X EZ-240-NMH-RA-X v TC-240-NMH-RA-1 3190-2891 3190-2893 3190-6143 3190-2426 5 6 7 8 i : TC-240-NMH-X TC-240-NMC VTVEZ-240-1023M TC-240-NF-BH-X 3190-2887 3190-244 3190-6283 3190-2888 9 10 12-13 11 EZ40-BM-X / TC-240-BM-X TC-240-NF-PM-X EZ-240-NF-X TC-240-BMC 1906120 - 3190-2890 3190-2889 3190-2795 3190-242 14 15 16 17. TC-240-BM-RA-D EZ-240-BM-RA-X EZ-240-TM-X TC-240-TM-X - 3190:2869 3190-2868 3190-2725 - 3190-2797 18 .- 20 21 -- 19 40TM-RA-D 3190-2798 EZ-240-TM-RP-X '-D EZ-240-TF-X EZ-240-TF-RP-X 3190-2892 - 3190-6204 3190-6167 22 23 !24 - ,- 25 - - EZ-240-QM-X 40- EZ-240-QM-RA-X EZ-240-SM-X TC-240-SM-SS-X 3190-2894 3190-2895 3190-2897 3190-2898 26 j 27 28 29 C 1 1 1 ( TC-240-SM-RA-SS-X EZ-240-SM-RA-X .-- TC-240-SM-RP TC-240-SF-SS-BH-X 3190-2900 3190-2899 3190-326 3190-2896 30 -- 31 32f - TC-240-MUHF \_..J TC-240-716M TC-240-716M-RA-D 3190-445 3190-2982 3190-2983 FMale StraighiPlug TC-240-FM-X 3190-2891 <1.25:1 (2.5) Knurl Solder Crimp N/G 1.1 (28) 0.45 (11.4) 0.014 (6.4) NMale StraightPlug EZ-240-NMH-X 3190-2893 <1.25:1 (2.5) Hex/Knurl SpringFinger Crimp A/G 1.5 (38.1) 0.78 (19.8) 0.086 (39.0) N Male RightAngle EZ-240-NMH-RA-X 3190-6143 <1.35:1 (6) Hex Spring Finger Crimp NG 1 (25.1) 1.04 (26.4) 0.115 (52.0) 20 (800) TMS-COAX • www.timesmicrowave.com 7rTIMES MICROWAVE SYSTEMS 4. NMale RightAngle TC-240-NMH-RA-D 3190-2426 <1.35:1 (6) Hex/Knurl Solder Crimp A/C 1.2 (32.4) 1.22 (31.0) 0.091 (41.7) S. NMale StraightPlug TC-240-NMH-X 3190-2887' <1.25:1 (2.5) Hex/Knurl Solder Crimp N/S 1.5 (36) 0.75 (19.1) 0.086 (39.0) 6. NMale StraightPlug TC-240-NMC 3190-244 <1.25:1 (2.5) Knurl Solder Clamp S/C 1.5 (38) 0.75 (19.1) 0.082 (37.2) 7.10/2.3 DIN StraightPlug EZ-240-1023M 3190-6283 <1.35:1 (2.5) knurl Spring Finger Crimp N/C 1.1 (2285) 0.33 (8.5) 0.014 (6.63) 8. NFemale Bulkhead Jack TC-240-NF-BH-X 3190-2888 <1.25:1 (2.5) NA Solder Crimp A/C 1.7 (44) 088 (22.2) 0.115 (52.2) 9.NFemale PanelMount TC-240-NF-PM-X 3190-2889W <1.25:1 (6) NA Solder Crimp A/C 1.7 (44) 0.88 (22.2) 0.115 (52.2) 10.NFemale StraightJack EZ-240-NF-X 3190-2795 <1.25:1 (6) NA SpringFinger Crimp A/G 1.4 (35.4) 0.62 (15.8) 0.040 (18.0) BNC Male StraightPlug TC-240-BMC 3190-242 <1.25:1 (2.5) Knurl Solder Clamp SIC 1.7 (43) 0.56 (14.2) 0.040 (18.1) BNC Male StraightPlug EZ-240-BM-X 3190-6120 <1.25:1 2.5 Knurl SpringFinger Crimp A/C 1.3 (34) 0.58 (14.7) 0.043 (19.5) BNC Male StraightPlug TC-240-BM-X 3190-2890 <1.25:1 (2.5) Knurl Solder Crimp A/C 1.3 (34) 0.58 (14.7) 0.043 (19.5) BNC Male RightAngle TC-240-BM-RA-D 3190-2869 <1.25:1 (2) Knurl Solder Crimp A/C 1.0 (25.1) 0.57 (14.5) 0.115 (52.0) BNC Male RightAngle EZ-240-BM-RA-X 3190-2868 <1.30:1 (4) KNURL SpringFinger Crimp A/C 1.3 (33.6) 1.19 (30.1) 0.091 (41.7) 16.TNC Male StraightPlug EZ-240-TM-X 3190-2725 <1.25:1 (2.5) Knurl Spring Finger Crimp N/C 1.4 (34.3) 0.59 (15.0) 0.043 (19.5) INC Mate StraightPlug TC-240-TM-X 3190-2797 <1.25:1 (2.5) Knurl Solder Crimp N/C 1.7 (43) 0.59 (15.0) 0.043 (19.5) INC Male Reverse Polarity EZ-240-IM-RP-X 3190-2892 <1.25:1 (6) Knurl SpringFinger Crimp A/C 1.4 (36) 0.59 (15.0) 0.043 (19.5) 19.INCMale RightAngle TC-240-IM-RA-D 3190-2798 <1,25:1 (6) Hex Solder Crimp A/C 1.0 (25.1) 0.62 (15.7) 0.115 (52.0) 20.INCFemale StraightJack EZ-240-IF-X 3190-6204 <1.25:1 (6) NA SpringFinger Crimp A/C 1.1 (272) 0.87 (22.0) 0.033(15.0) 21.INCFemale ReversePolarityEZ-240-IF-RP-X 3190-6167 <1.35:1 (6) NA SpringFinger Crimp A/C 1.1 (27.2) 0.87 (22.0) 0.033(15.0) 22.QMAMale StraightPlug EZ-240-QM-X 3190-2894 <1.25: (6) Knurl SpringFinger Crimp N/C 1.2 (30.0) 0.41 (10.5) 0.014 (6.35) 23.QMA Male RightAngle EZ-240-QM-RA-X 3190-2895 <1.25: (<6) Knurl SpringFinger Crimp N/C 0.8 (20.3) 0.65 (16.5) 0.019 (8.62) SMA Male StraightPlug EZ-240-SM-X 3190-2897 <1:25: (6) Hex Spring Finger Crimp N/C 1.0 (25.4) 0.32 (8.1) 0.016 (7.26) SMA Male StraightPlug IC-240-SM-SS-X 3190-2898 <1.25:1 (10) Hex Solder Crimp SSIC 1.0 (25) 0.32 (8.1) 0.016 (7.3) SMA Male RightAngle IC-240-SM-RA-SS-X 3190-2900 <1,35:1 (6) Hex Solder Crimp SSIC 0.8 (20) 0.65 (16.5) 0.019 (8.6) 27.SMAMale RightAngle EZ-240-SM-RA-X 3190-2899 <1,25:1 (6) Hex SpringFinger Crimp A/C 0.9 (22.8) 0.31 (7.9) 0.019 (8.6) SMA Male Reverse Polarity lC-240-SM-RP 3190-326 <1.25:1 (2.5) Hex Solder Crimp SSIG 1.0 (25) 0.32 (8.1) 0.016 (7.3) SMAFemate Bulkhead Jack TC-240-SF-SS-BH-X 3190-2896'<1.25:1 (2.5) NA Solder Crimp SSIG 1.1 (29) 0.31 (7.9) 0.019 (8.6) 130. Mini-UHF StraightPlug IC-240-MUHF 3190-445 <1.25:1 (2.5) Knurl Solder Crimp N/C 1.1 (28) 0.45 (11.4) 0.014 (6.4) 7/16 Din Male Straight Plug IC-240-716M 3190-2982 <1.35:1 131 Hex SpringFinger Crimp A/S 2.0 (50.5) 1.26 (32.0) 0.186 (84.4) 7/16Din Male RightAngle IC-240-716M-RA-D 3190-2983 <1.35:1 (3) Hex Solder Crimp A/S 1.4 (343) 1.60 (40.6) 0.239 (108.5) *Finish metals: N=Nickel, S=Silver, C=Cotd, SSStainless Steel, A=Alballoy **VS spec based on 3 foot cable with a connector pair*Available in bulk pack "aird waire Accessories Ground Kit GK-5240T1 GK-S240TT Standard Ground Kit (each) Weatherproof Kit WSB-240 3109-400 Weatherproof/Strain relief kit for LMR-240 WSB-240 3109-400 GK-S24OTT cT-240/200/195/100 3190-667 3192-165 3192-162 3192-001 O lm stm oo cU©o5s 3192-086 Crimp Tool CT-240/200/195/100 3190-667 Crimp tool for LMR-100, 195, 200 and 240 connectors Strip Tool CST-240A 3192-152 Prep tool for LMR-240 connectors Deburr Tool DBT-U 3192-001 Removes center conductor rough edges Cutting Tool CCT-02 3192-165 Cable end flush cut tool Replacement Blade RB-02 3192-166 Replacement blade for cutting tool Replacement Blade Kit RB-CST 3192-086 Replacement blade kit for all CST strip tools (800) TMS-COAX • www.timesmicrowave.com 21 CELLMAX-O-CPUSEI Cell-MaxTM 0mn1 In-building Antenna, 698-960 MHz and 1710-2700 MHz Product Classification Product Type Product Brand General Specifications Application Antenna Type Antenna Array Characteristic Polarization Color Mounting Number of Ports Pigtail Cable Radome Material RF Connector Interface Dimensions Height Pigtail Length Outer Diameter In-building antenna Cell-Max Indoor Omni SISO Vertical White (RAL 9016) Thru-hole ceiling mount (optional) 670-141 SXE, plenum rated ABS N Female 85 mm I 3.346 in 500 mm I 19.685 in 186 mm I 7.323 in Page] of 3 3 [ELLMAX-O-CPUSEI Outline Drawing Electrical Specifications Electrical Note Impedance Operating Frequency Band 1710-2700MHz 1 698-960MHz PIM specifications are less than or equal to the stated value 50 ohm Electrical Specifications Frequency Band, MHz Gain, dBi Beamwidth, Horizontal, degrees VSWR I Return loss, dB 698-800 800-960 2 2 360 360 1.8110.9 1.5114,0 1710-2700 5 360 1.5 114.O Page 2 of 3 CELLMAX-O-CPUSEI PIM, 3rd Order, 2 x 20W, dBc -140 -140 -140 Input Power per Port, maximum, watts 50 50 50 Environmental Specifications Operating Temperature Relative Humidity Packaging and Weights Height, packed Width, packed Length, packed Packaging quantity Weight, gross Weight, net -40 °C to +60 C (-40 °F to +140 °F) Upto 100% 135mm I 5.315 in 195 mm I 7.677 in 195mm I 7.677in 0.4 kg I 0.8821b 0.3 kg I 0.6611b Regulatorçj Compliance/Certifications Agency Classification CHINA-ROHS Below maximum concentration value ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance ROHS Compliant .Ms 9001:2015 Page 3 of 3 fit i C - - j '1!i11_ 1f1ir Y8066 and Y8063 shown with YM78HD Heavy Duty Mounting Kit Voyager Field tunable for quick field deployment Rugged design performs in harsh environments UV inhibiting insulators will not crack, decay, or disassemble with UV exposure . VG1SO5 and VG4505 shown with optional FM2 Mounting Kit Directional Yagis 360 Fully Welded Gold Anodized mcdels or value leader Silver Series available Line up includes 3 element/7.1 dBd gain to 18 elementl14 dBd gain variatiors Internal matching design will not ice up, detune, or corrode OF Custom tuning available Model Frequency Range Gain Length Extended Length WHFModels V61502 150-174 MHz 2dBi 55' 102' V61325 132-150 MHz 5 55" 102" VG1505 150-174 MHz 5dBi 55' 102' VG1326 132-150 MHz 6dBi 55" 102" VG1506 150-174 MHz 6 55" 102" V02002 200-225 MHz 2 55" 102" LJHF Models VG4065 406-450 MHz 5 dBi 25" 35" VG4505 450-512 MHz 5dBi 25" 35" VG4506 450-512 MHz 6 d8i 25" 35" Model Description Mast IVIounting Options 1 FM1 Stainless Steel U Bolt Mount (2) 1 7/8" FM2 Heavy Duty Base Mounting Bracket (2) 2 1/2' Model Frequency Elements Gain Front-Back Boom Boom Ratio Length Diameter EJAnodized Non Welded VHF Models Y1363 136-150 MHz 3 7.1 dBd 17 dB 41-1/2" 7/8" Y1365 136-150 MHz 5 9.2 dBd 20 dB 72" 1-1/4" Y1503 150-174 MHz 3 7.1 dBd 17 dB 41-1/2" 7/8" Y1505 150-174 MHz 5 9.2 dBd 20 dB 72" 1-1/4" '(2203 220-250 MHz 3 7.1 dBd 17 dB 41-1/2" 7/8" Y2205 220-250 MHz 5 9.2 dBd 20 dB 72" 1-1/4" 153old Anodized Fullv Welded VHF Models* YXXX3W User Defined 3 7.1 dBd 17 dB 41-1/2" 7/8" YXXX5VV User Defined 5 9.2 dBd 20 dB 72" 1-1/4" .may require truck freight [d Anodized fülIv Welded UHF Models '(4065 406-430 MHz 5 9.2 dBd 20 dB 37" 7/8" Y4066 406-430 MHz 6 10.2 dBd 20 dB 44" 7/8" '(4303 430-450 MHz 3 7.1 dBd 17 dB 20-3/16" 7/8" '(4305 430-450 MHz 5 9.2 dBd 20 dB 37" 7/8" Y4306 430-450 MHz 6 10.2 dBd 20 dB 44" 7/8" Y43012 430-450 MHz 12 11 dBd 20 dB 68-1/16" 1-1/4" '(4503 450-470 MHz 3 7,1 dBd 17 dB 20-3/16" 7/8" Y4505 450-470 MHz 5 9.2 dBd 20 dB 37" 7/8" '(4506 450-470 MHz 6 10.2 dBd 20 dB 44" 7/8" Y45012 450-470 MHz 12 11 dBd 20 dB 68-1/16" 1-1/4" '(4705 470-490 MHz 5 9.2 dBd 20 dB 37" 7/8" Y4706 470-490 MHz 6 10.2 dBd 20 dB 44" 7/8" oji Anodized Fully Welded 8/0 MHz Models '(8063 806-896 MHz 3 6 dBd 15dB 16-3/4" 7/8" '(8066 806-896 MHz 6 9dBd 16 dB 27-11/16" 7/8" ,Y80612 806-d96 MHz 12 11 dBd 20 dB 48-7/8" 7/8" '(8963 896-970 MHz 3 6 dBd 15 dB 163/4" 7/8" '(8966 896-970 MHz 6 9d8d 16 dB 2711/16" 7/8" '(89612 896-970 MHz 12 11 dBd 20 dB 48-7/8" 7/8" '(80618 806-896 MHz 18 14 dBd 25 dB 697/8" 1" '(89618 896-870 MHz 18 14 dBd 25 dB 697/8" 1" More Info: 800.323.3757 Items printed in green are in-stock and available for immediate delivery www(airdtech.cem n~, DASalert Models 1221-A & 1221-B Meets NFPA-72 (2010, 2013 & 2016) and current NFPA-1221 codes for a Dedicated Annunciator and Monitoring Panel Displays Status of: BDA Donor Antenna AC Power Battery Capacity Battery Charger System Status Includes Form-C relay contacts to interlace with any fire alarm system Monitors communications link for integrity Includes independent circuitry to check antenna, AC power, battery capacity, charger and overall system status Mates with or augments monitoring of any BDA, antenna, charger, battery or UPS Low cost, easy to install and program Small size NEMA-4: 10"H x 8"W x 4"D Backed up by internal battery (included) Easy installation to optional primary power sources: 48 VDC or 24 VDC, or 120 VAC Model 1221-A Monitor and Annunciator Panel Typical Application BDA 'AC POWER I 'ANTENNA CHARGER Am~c —120 VAC Comm fAULT Fault Outputs to flre Alarm System To Indoor 24-Hour Optional DC Power Antennas Code Requirements The current edition of the NFPA 1221 fire code (shown below) and NFPA-72 (2010, 2013 & 2016) describe the requirements for monitoring the performance of Public Safety in-building two-way Radio Enhancement Systems with a dedicated panel. This panel is required to be located in the fire command center but some jurisdictions require that it be located in the same room as the Radio Enhancement System. These panels are designed to meet all these requirements. In addition, Model 1221-A contains additional circuitry to enhance and augment the alarm sensing capabilities of the BDA and the DAS backup emergency power supply if they are not code compliant. Fault Signaling Relays Some DAS components are not configured with the appropriate Form-C alarm relays that can interface properly with all Fire Alarm Systems. This unit provides these alarm relays. They can be programmed to mate with any Fire Alarm System with their 'normally OFF' or 'normally ON' states for any 'fail safe' convention that is required by the Fire Alarm System. Enclosure & Power Requirements The enclosure is NEMA-4 rated consistent with the other requirements of the code and a small backup battery (included) inside the panel provides over 24 hours of service if this is needed to supplement loss of primary power. Primary power is provided by an AC socket-mounted 15 VDC power supply (included). Communication Integrity Per code, fault detection cables between the Radio Enhancement System and the panel are monitored to detect open circuits or short circuits to ground. If this condition is detected the panel will trigger a fault alarm to the Fire Alarm System signaling the loss of communications integrity. Antenna Monitoring (Model 1221-A) If the bi-directional amplifier (BDA) in the Radio Enhancement System does not have the capability to monitor donor antenna faults, the panel can provide this by adding external Bias-Ts in line with the antenna. The panel will detect common faults such as open circuits, short circuits, disconnected or severed cables leading to the antenna without impacting the RF performance of the system. Installation This panel provides an economical easy-to-install solution to meeting the code requirements and the flexibility to interface with and augment, if required, the fault detection and alarm signaling capabilities of a large variety of standard components used in these systems. The small size and light-weight enclosure can be wall-mounted into any installation. Model Comparison Module Model 1221 A Model 1221 B Annunciator System with FORM-C relay outputs to main fire alarm installation / Alternative Donor Antenna Failure Sense Module (Bias-T fittings not included) / Alternative DAS Battery Capacity Sense Module / Alternative DAS Battery Charger Failure Sense Module I Annunciator System Backup Battery (9 Ahr) I I Annunciator System Power Supply and Battery Charger / I Price $1600.00* $110 * Prices shown are for standard 120 VAC powered models. Add $90 for 48 VDC or 24 VDC powered models. Models 1221A and 1221B Module Descriptions Annunciator System with FORM-C relay outputs to main fire alarm system (Models 1221A & Model 1221B) This is the basic annunciator system that accepts ALARM signaling from external relays contained in the DAS equipment. The system accepts relay signaling indicating the following alarms: Loss of AC Power Amplifier Problems Antenna Problems DAS Battery Capacity below 30% DAS Battery Charger Fail Communications Faults Summary System Alarm The annunciator system provides FORM-C dry relay contacts to provide alarm signaling with any fire alarm installation. The system will operate with DAS installations that include multiple amplifiers, antennas and power sources, and includes circuitry to detect communications faults (open or short circuits) with the DAS equipment. Annunciator System Backup Battery Both models are shipped with an 9 Ahr rechargeable SLA battery that mounts inside the enclosure to provide over 24 hours of backup power. Annunciator System Power Supply and Charger Both models are shipped with an external 15 VOC power supply and battery charger that can be connected to any 120 VAC power outlet. The battery charger includes indicators that show the health of the panel's backup battery. The need to replace this battery can be signaled to the building's main fire alarm system. Alternative Donor Antenna Failure Sense Module (Model 1221-A only) This module provides a means of detecting open circuit, short circuits, disconnected, severed or lose connector problems in the antenna feed from the donor. This circuitry utilizes external bias-T fittings (not included). Multiple antennas can be connected in parallel to the same monitoring port. Model 1221A should be used if your amplifier or other components in your installation do not have the means of detecting donor antenna problems. Alternative DAS Battery Capacity Sense Module (Model 1221-A only) If your installation has a backup battery to provide emergency DAS power in the event of an AC power failure it must be monitored to detect when it has less than 30 % capacity left to power the system when primary power is lost. Model 1221A should be used if your emergency power unit does not have this capability. Alternative DAS Battery Charger Failure Sense Module (Model 1221-A only) If your installation has a backup battery to provide emergency DAS power in the event of an AC power failure, the battery charger must be monitored to detect if it has failed or is degraded. Model 1221A should be used if your charger unit does not have this capability. Excerpted from NFPA 1221 (2016 Edition): Similar requirements in NFPA-72 (2010, 2013, 2016) Standard for Installation, Maintenance, and Use of Emergency Services Communications System 9.6.13.2 Dedicated Panel. (1) A dedicated monitoring panel shall be provided within the fire command center to annunciate the status of all RF emitting devices and system component locations. The monitoring panel shall provide visual and labeled indications of the following for each system component and RF emitting device: Normal ac power Loss of normal ac power Battery charger failure Low battery capacity (to 70 percent depletion) Donor antenna malfunction Active RF emitting device malfunction System component malfunction (2) The communications link between the dedicated monitoring panel and the two-way radio communications enhancement system must be monitored for integrity. Specifications Dimensions Weight 10" x 8" x 4" Fault inputs from Radio Enhancement System Donor Antenna OK I Fail 11.7 lbs Amplifier OK / Fail Charger OK / Fail Battery Capacity OK / Low Form C Dry Relay Outputs to to Fire Alarm System AC Power AC Power ON / OFF System (Summary Alarm) Analog Inputs Donor Antenna Sense Amplifier (BDA) DAS Battery Antenna Battery a ery Charger Certifications UL: E65324, [IL: 4002961 Battery _Capacity Communications Fault Power 120 VAC, 24 VDC or 48 VDC (100 mA max) E. i) II 3J t#]SX5 1] 11IP1IjII .it GX Seres The GX Series of RF DC pass surge arrestors are engineered for RE coaxial applications where DC current is needed on the coaxial line. The GX Series can be used on GPS and other active antenna systems that operate in the range from DC 1 to2700MHz. N FEATURES Frequency ranges from DC to 2.7 GHz Patented hybrid surge protection Repeatable RF performance after surge Flexible bulkhead and bracket mounting options Weatherproof when installed 7/16 DIN, N-Type and TNC STANDARDS Weatherproof: lEC 60529 IP 67 Bellcore TA-NWT-000487 Procedure 4. 11, Wind Driven (120 MPH) CE and RoHS PATENTED LIGHTNING ARRESTOR TECHNOLOGY The GX product family is based on PolyPhaser's patented hybrid protection technology. This hybrid circuit integrates the quick response of a silicon avalanche suppression diode (SASD) with the surge handling capabilities of a MOV and gas tube. The GX technology has been field tested for more than a decade and has been used in critical RF networks world-wide. SCHEMATIC r_TIT GENERAL SPECIFICATIONS* Insertion Loss !~0.10 VSWR :91.1 or Better Over Frequency Range Return Loss <26dB Max Operational Current 4A Typical Surge Withstand 20kA 8120ps Waveform GXJ Bias-I SMA Connector as DC Injector 1st Three Identifiers Frequency Range AGX DC to 50MHz BOX 40MHz to 400MHz CGX 400MHz to 1200MHz DGX 800MHz to 2500MHz Type Description E Extended Frequency H High Power J Bias-I w/ Injector Port Z DC-Pass Connector Types Description D 7/16" DIN N N-Type I INC Example of Naming Convention for GX Family** D GX J + 06 D M F A Frequency Series Type Positivity Voltage Surge Side Surge Side Protected Side Lid Band Connector Connector Connector Configuration Type Gender Gender *Confirm with product specific datasheet for detailed specifications **Not all combinations available 1464-044 RevD c) PolyPnaser 1,017 AT rratrts reserved AVAILABLE GX PART NUMBERS Pa ITh1I1TTh,Ie AGXZ+15TFTF-A j1'[ DC-50MHz i1i!(. TNC 15V 1W Energy" :51000pJ BGXZ-60NFNF-AT 40MHz - 400MHz N-Type BOV ioow 52.5mJ BGXZ-60NFNF-CNS 40MHz - 400MHz N-Type 60V 100W :525mJ BGXZ-60NFNM-ALT 40MHz-400MHz N-Type 60V 100W 152,5m3 BGXZ-60NFNM-AS 5MHz-400MHz N-Type 60V 40W :52,5mJ CGXi+15NFNF-A 400MHz - 1.2GHz N-Type 15V 300W 525pJ CGXJ+36NFNF-A 400MHz - I .2GHz N-Type 36V 300W 525pJ CGXZ+15NFNF-A 400MHz -1.2GHz N-Type 15V 300W 5500pJ CGXZ+15NMNF-A 400MHz - 1.2GHz N-Type 15V 300W 15500pJ CGXZ+36NFNF-A 400MHz - 1.2GHz N-Type 36V 300W 51500pj CGXZ+36NMNF-A 400MHz - 1.2GHz N-Type 36V 300W 51000pJ DGXE+24DMDF-A 400MHz - 2.5GHz 7/16' DIN 24V 600W ~1 mJ DGXE+3ONMNF-A 650MHz - 2,7GHz N-Type 30V 400W 51.5mJ DGXH-'48DMDF-A BOOM Hz-2,5GHz 7116" DIN 48V 500W sl46pJ DGXJ+24NFNF-A 800MHz - 2.5GHz N-Type 24V 300W s25pJ DGXJ-24NFNM-A BOOM Hz - 2.5GHz N-Type 24V 300W 25J DGXZ+OBDFDF-A BOOM Hz - 2.5GHz 7/16" DIN 6V 300W s175pJ DGXZ#OBDMDF-A 800MHz- 2.5GHz 7/16" DIN 6V 300W :5175pJ DGXZ'406NFNF-A 800MHz - 2.5GHz N-Type 6V 300W !075pJ DGXZ+06NFNF-8 BOOM Hz- 2.5GHz N-Type 6V 300W :5175pJ DGXZ-s06NFNF-F BOOM Hz - 2.5GHz N-Type SV 300W 5175pJ DGXZ+OBNFNM-A BOOM Hz - 2,5GHz N-Type 6V 300W :5175pJ DGXZ+06NFNM-B BOOM Hz - 2.5GHz N-Type 6V 300W :5175pJ DGXZ+06NMNF-A 800MHz-2,5GHz N-Type 6V 300W !0751JJ DGXZ.00NMNF-Z 800MHz - 2.5GHz N-Type 6V 300W 15175PJ DGXZ+06TFTF-A 800MHz-2.5GHz TNC 6V 300W 15175pJ DGXZ+15DMDF-A 800MHz - 2.5GHz 7/16" DIN 15V 300W :55001JJ DGXZ.15NFNF-A 800MHz - 2.5GHz N-Type 15V 300W 15500pJ DGXZ+15NFNM-A 800MHz - 2.5GHz N-Type 15V 300W !~500pJ DGXZ+15NMNF-A BOOM Hz- 2.5GHz N-Type 15V 300W 5500iJ DGXZ+15TFTF-A BOOM Hz-2,5GHz TNC 15V 300W 500pJ DGXZ+15TFTF-BN BOOM Hz - 2.5GHz INC iSV 300W 5500jjJ DGXZ.36NFNF-A 800MHz - 2.5GHz N-Type 36V 300W :51.5mJ DGXZ*36NMNF-A 800MHz - 2.5GHz N-Type 1 36V 300W ~51.5mJ DGXZ-BONFNF-A 800MHz - 2.5GHz N-Type 1 BOV 300W :52,5mJ ** Measured under a 3kA 8/20us Waveform DIMENSIONS ft t Wideband Directional Coupler DC-Exx-ON200L(XH) Low PIM(-153dBc), 138-960MHz, N-Female, 200W C@Mha keeps you connected Wideband design covering 138-960MHz Public Safety band (VHF & UHF & 700/800MHz) Available in 6, 10, 15 and 20dB values Suitable for indoor/outdoor environment High reliability and low insertion loss Electrical Specification Product Model Frequency (MHz) Coupling (dB) Coupling Tolerance (dB) 138-340MHz 340-960MHz Insertion Loss (dB) Directivity (dB) VSWR @ all ports PIM (dBc) Reflection Power, max (W) Average Power, max (W) Peak Power, max (W) Impedance (ohm) DC-E06-ON200L(XH) DC-E10-ON200L(XH) Dc-E15-ON200L(XH) Dc-E20-ON200L(XH) 138-960 6.0 10.0 15.0 20.0 ±1.5 ±1.5 ±1.7 ±1.7 ± 1.0 ±1.2 ± 1.3 ±13 5 1.9 15 1.2 5 0.6 5 0.5 20 51.25 ~-153 @ 2x43dBm 40 100 200 200 200 1000 50 Mechanical Specification Environment & Compliance Dimension (in/mm) 9.45x1.69x0.87 / 240.0x43.0x22.0 Application Indoor / Outdoor Weight (lb/kg) 1.37/0.62 Operating Temperature -35°C to +85°C Shipping Dimension (in/mm) 12.71x3.46x1.57 / 322.0x87.009.0 Environment 1P65 Shipping Weight (lb/kg) 1.63/0.73 Relative Humidity Up to 100% Connector N-Female RoHS Compliant Outline Drawing OS-Control Comba Telecom Inc. 568 Gibraltar Drive, Milpitas, CA 95035. http://www.combausa.com/ Page lot 1 0-0-1/0319 Tel: +18668027961, Combausa(Scomba-teIecom.cQrn. Fax: +1408 526 0181 Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers requirements C@Mhu Wideband Power Splitter keeps you connected PS-E2-ON50M(XH)/PS-E3-ON50M(XH)/PS-E4-ON50M(XH) 2/3/4 Way, Low PIM(-1530c), 138-960MHz, N Female, 50W Wilkinson power splitter for Public Safety Band Wideband design covering 138-960MHz, Public Safety Band (VHF, UHF & 700/800HMz) Suitable for indoor/outdoor environment High reliability and low insertion loss Electrical Specification Product Model PS-E2-ON50M(XH) PS-E3-ON50M(XH) PS-E4-ON5OM(XH) 2-Way 3-Way 4-Way Frequency (MHz) 138-960 Split Loss (dB) 3.0 4.8 6.0 Insertion Loss (dB) 15 0.5 0.8 50.7 Isolation (dB) 20 18 >20 VSWR @ all ports 15 1.2 15 1.25 15 1.25 PIM (dBc) @550-960MHz 5-153 @ 2x43dBrn Average Power, max (W) 50 Impedance (ohm) 50 Mechanical Specification Dimension (in/mm) 5.49x6.54x0.87 / 139.5x166.1x22.0 5.71x8.84x0.87 / 145.0x224.6x22.0 6.91x8.23x0.87 / 175.5x209.1x22.0 Weight (lb/kg) 1.28/0.63 2.02/0.91 2.30 /1.04 Connector Type N Female N Female N Female Environment & Compliance Application Indoor / Outdoor Operating Temperature -25°C to +85°C Environment 1P65 Relative Humidity Up to 100% RoHS Compliant Outline Drawing DS-Control Comba Telecom Inc. 235 Charcot Avenue, San Jose, CA 95131. htto://www.combausa.com/ Page 1 of 1 104/ 0817 Tel: +1866 802 7961, combausaconiba-teIecom.com, Fax: +1408 526 0181 Information contained in this document is subject to confirmation at time of ordering. Specifications may differ depending on region and customers requirements 21+10881 Standard Grounding Kit for 1/2 in corrugated coaxial cable and elliptical waveguide 180 and 220 Product Classification Product Type Ordering Note General Specifications Bonding Conductor Jacketing Material Bonding Conductor Material Bonding Conductor Wire Size Cable Type Color Grounding Kit Type Grounding Strap Material Lug Attachment Lug Type Thread Size Dimensions Bonding Conductor Length Cable Jacketing Removal Length, maximum Cable Jacketing Removal Length, minimum Compatible Diameter, maximum Compatible Diameter, minimum Nominal Size Waveguide Size Electrical Specifications Grounding kit CommScope® non-standard product PVC Copper 6 gauge Corrugated I Elliptical waveguide Black Standard Grounding Kits Copper Factory attached Two-hole lug 3/8 in 609.6 mm I 24 in 58.42 mm I 2.3 in 55.88 mm I 2.2 in 16.51 mm I 0.65 in 15.494 mm I 0.61 in 1/2 in WR42 I WG20 I R220 I WR51 I WG19 I R180 Page 1 of 3 21+10881 Current Handling Current Handling Test Method Grounding, Bonding and Shielding Test Method Lightning Protection Test Method Material Specifications Rivet Material Tested to withstand 100,000 amps peak current surge MIL-STD-1757 MIL-STD-188-124A IEC 1024-1 Copper Environmental Specifications Operating Temperature Storage Temperature Blowing Rain Test Method Corrosion Test Method Freezing Rain/Icing Test Method Humidity Test Method Immersion Test Method UV Resistance Test Method Vibration Test Method Weatherproofing Method Packaging and Weights -40°C to +85 °C (-40°F to +185 °F) -40°C to +80°C (-40°F to +176 °F) MIL-STD-810, Method 506 MIL-STD-1344, Method 1001 MIL-STD-810, Method 521 MIL-STD-1344, Method 1002 IEC 60529:2001, 1P68 MIL-STD-810, Method 505 MIL-STD-202, Method 214 Butyl and electric tape Height, packed 266.7 mm 10.5 in Width, packed 266.7 mm 10.5 in Length, packed 58.42 mm I 2.3 in Included Grounding kit I Hardware I Lug I One roll of 2 in PVC tape I One roll of 24 in butyl rubber tape Packaging quantity Weight, gross 0.72 kg I 1.587 lb Regulatorij Compliance/Certifications Agency Classification CHINA-ROHS Below maximum concentration value ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance ROHS Compliant Page of 3 21+10881 ncluded Products 42615-10 - Butyl Rubber Tape, 24 in 9905-71 Black 2 in PVC Tape, 20 ft * Footnotes Grounding, Bonding and Shielding Test Method Military Standard for Grounding, Bonding, and Shielding: Bond Resistance Requirement of a Maximum dc resistance of 0.001 ohm Lightning Protection Test Method Protection Against Lightning Electromagnetic Impulse, Table 1—Protection Level Ill—IV, 1995-02 Page 3 of 3 FRM NON-PENETRATING The FRM mount is a lightweight mount and is galvanized for corrosion protection. The FRM mount is easily shipped via UPS. Order (1) optional FRMMAT (1/8"thick) or (1) optional FRM PAD (3/8"thick) for a protective barrier between the mount and the roof. Order (1) optional SCK1 50 safety cable kit (3/8" x 150'). 1.25" to 2.38" Mast Tube Diameters 2.5' and 5'Overall Mast Heights (See Most Descriptions) 16" Nominal Blocks 3' Square FRM BALLAST REQUIREMENTS MAST SPECIFICATIONS Mount Part No. Mast Part No. Mast Description & Height FRM125 FY202 1.25"O.D.x 16 GA. x 5.0'(PG) FRM 150 FY203 1.50" O.D. x 16 GA. x 2.5' (PG) FRM166 FY204 1.66"O.D.x 16 GA.x 2.5'(PG) FRM238 FY205 2.38"O.D. x 0.154" wall x 2.5' (HDG) FRM225 FY205SP 2.25"O.D. x 14 GA. x 5.0'(H DG) FRM238SP5 FY253 2.38"O.D. x 0.154' wall x 5.0'(H DG) Effective Zero Vmax at centroid of projected area, (MPH) Projected Ballast Velocity Vs Area (EPA) (LBS) Load (MPH) (FT 2) (PSF) h=2 FT h-3 FT h=4 FT h=5 FT 100 12 140 135 110 96 85 2 200 24 198 188 153 133 119 300 36 242 222 182 157 (154) 141 (131) 400 48 280 269 219(197) 190)154) 170(131) 100 12 99 96 78 68 60 4 200 24 140 133 108 94 84 300 36 171 157 129 111 99(93) 400 48 198 190 155(139) 134(109) 120(93) 100 12 81 78 64 55 49 6 200 24 114 108 88 77 68 300 36 140 128 105 91 (89) 81 (76) 400 48 161 155 127(114) 110)89) 98(76) PG = Pre-galvanized most h = Distance from support surface to centroid of EPA. HDG = Hot-dip galvanized most Vs = Effective wind velocity resulting in sliding on a flat surface with a .50 coefficient of friction. Vmax = Effective wind velocity based on strength or overturning. NOTE:The velocities in ( ) apply to the FRM1 25 mount when the strength of the FRM1 25 mast governs. Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The industry Sondord