Loading...
HomeMy WebLinkAbout2700 ARGONAUTA ST; ; FPR2021-0062; Permit4ity of Carlsbad ne1PeTr.mit Print Date: 05/25/2022 Job Address: 2700 ARGONAUTA ST, CARLSBAD, CA 92009 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2154600500 Track #: Valuation: $915,872.82 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2021-0062 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 06/22/2021 Issued: 07/13/2021 DEV2019-0049 Finaled Close Out: 05/25/2022 Final Inspection: INSPECTOR: Cheung, Nathaniel Salcedo, Felix Project Title: 2700 ARGONAUTA RESIDENCE Description: ARGONAUTA RESIDENCE -NEW 13D SYSTEM FOR NEW SFR (50 HEADS) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 9475 CHESAPEAKE DR 12155 PAINE PL SAN DIEGO, CA 92123-1336-SAN DIEGO POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov Hydraulic Calculations for Project Name: ARGONAUTA RESIDENCE Location: 2700 ARGONAUTA ST. CARLSBAD, CA 92009,, Drawing Name: ARGONAUTA RES 20-0447 Calculation Date: 6/17/2021 Design Remote Area Number: 1 Remote Area Location: UNIT Occupancy Classification: RESI 1 HD Density 0.050gpm/ft2 Area of Application: 400.00ft2 (Actual 39.11ft2) Coverage per Sprinkler: 400.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 1 No. of nozzles calculated: 0 In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type: Allowance at Source 5.00 at Node: 5 Type: Hose Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 26.00 (Safety Margin = 7.022) Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: KW BUILDING Address: 1460 ORPHEUS. ENCINITAS, CA 92024, Phone Number: Name of designer: CHRISTIAN MENDOZA Authority Having Jurisdiction: CARSLBAD FIRE DEPT. Notes: Automatic peaking results Left: N/A Right: N/A ,©M.E.P.CAD, Inc. JAutoSPRINK 2020 06.3.4.0 1 6/17/2021 1:21:29PM Page 1 1000 800 900 '*CJU bUU 500 700 Flow - gpm Hydraulic Graph N 1.85 Date: 6/17/2021 Water Supply I Summary Sheet Node:1 wailable Supply Static Pressure 26.00 0 - - 00 00 61.400 . . 6.00 @ 55.374 System demand curve_______ _ll.LI.LLU.!ICIIIIIICIIIIIIIIC 11111111 111111111 11111111 liii II I II 111111 I I I I I I I I 9c 8C 7C 3C 2C 1c Job Name: ARGONAUTA RESIDENCE Remote Area Number: 1 100 I&,©M.E.P.CAD, Inc. IN AutoSPRINK 2020 06.3.4.0 6/17/2021 1:21:32PM Page 6C C,) 5C 0 4C Isummary of Outfiowing Devices Job Number: 20-0447 ,©M.E.P.CAD, Inc. M AutoSPRINK2020v16.3.4.0 6/17/2021 1:21:33PM Page Job Name: ARGONAUTA RESIDENCE Remote'Area Number: I Date: 6/17/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 62.400 61.400 500.00 62.396 26.00 55.374 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 517'-11',4 Supply 55.374 26.00 5 520'-5V 27.671 5.00 201 527-0 Sprinkler 18.367 21.00 2 520-11Y2 48.764 3 520-11% 30.351 4 516-11% 30.320 6 520111/2 26.689 7 527-6 21.000 8 527-6 20.913 9 527-6 19.896 ,©M.E.P.CAD, Inc. AutoSPRlNK 2020 v1 6.3.4.0 6/17/2021 1:21:36PM Paqe4 Job Name: ARGONAUTA RESIDENCE Renote Area Number: 1 Date: 6/17/2021 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) ___________ C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Friction(Pf) 201 527-0 4.9 21.00 1 (See Notes) 8'-5 150 18.367 flE1+IS .... Route I Sprinkler , 2E(5'-O), 1(5-0) 15-0 0.074468 -0.217 9 527-6 21.00 1.1010 23-5 1.745 9 527-6 1 (See Notes) 56'10Y2 150 19.896 E(5'-O), 1(5-0) io-o 0.016512 7 527-6 • 9.30 1.1010 66-10% 1.104 7 527-6 11.70 1. (See Notes) 1541/2 150 21.000 Flow (q) from Route 2 2E(5-0), 2f, 3Tr(1'-0), CV(5'-0), 1(5-0) 23-0 0.074468 2.830 6 520-11% 21.00 1.1010 38-4'/2 2.859 6 520'-11'/2 1 (See Notes) 0'6 150 26.689 1(6-9) 6-9 0.105499 0.217 5 520-5% 21.00 1.0250 7-3 0.764 5 520-51/2 5.00 1 (See Notes) 4'6 150 27.671 E(2'-8%) 2-8% 0.156619 1.522 4 516-11% 26.00 1.0250 7-2% 1.127 4 516-11% 11/2 (See Notes) 71'O 150 30.320 3E(9'-O) 27-0 0.018016 -1.734 3 520-11% 26.00 1.5980 98-0 1.766 3 520-11% 1 (See Notes) 7'3% 150 30.351 3E(2'-8%), BFP(-12.000),WMV (-4.000) 8-1 0.156619 2 520-11% 26.00 1.0250 15-5 18.413 2 520111,4 . 1 (See Notes) 27'-0 150 48.764 E(2'-4), S 2-4 0.180997 1.301 1 517-11% 26.00 0.9950 29-4 5.309 0.00 55.374 Hose Allowance At Source Total(Pt) Route 1 1 26.00 9 527-6 9.30 1 4-5 150 19.896 ..... Flow (q) from Route 1 0.025224 10 527-6 11.70 1.1010 4-5 0.112 10 527-6 i (See Notes) 88'6 150 20.007 .Route2 21(5-0), 2E(5-0) 20-0 0.008346 FO.=905 B 527-6 6.43 1.1010 108-6 (,©M.E.P.CAD, Inc. AutoSPRINK2O2Ov16.3.4.O 1 6/17/2021 1:21:38PM Page Job Name: ARGONAUTA RESIDENCE Remote Area 'Number: I Date: 6/17/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) ___________ Pt Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total (Foot) (Q) (Foot) (Foot) (psi) Friction(Pf) directly to (Pt) and shown as 8 527'-6 5.26 1 3-5% 1 150 20. 913 Flow (q) from Route 3 0.025224 7 527-6 11.70 1.1010 0.087 21.000 Total(Pt) Route 2 10 527-6 1 (See 1063 150 20.007 Route 3 ..... Notes) 51-0 T(5-0) 8 527-6 5.26 1.1010 0.005758 5E(5'-O), 2T(5-0), 2C(5'-O), 157-3 0.905 cplg(1'-O) 20.913 Total(Pt) Route 3 ),©M.E.P.CAD, Inc. §1 AutoSPRlNK 2020 06.3.4.0 1 6/17/2021 1:21:38PM Page 6 Job Name: ARGONAUTA RESIDENCE Remote Area Number: I Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter 4.87 I = Factor Schedule 40 Steel Pipe Inside Diameter J Date: 6/17/2021 IC Value Multiplier - I Value OfC 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 111/40 Elbow Ee2 22%' Elbow f Flow Device Id Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PlV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer I Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap 19 , © M.E.P.CAD, Inc. §1 AutoSPRINK 2020 06.3.4.0 1 6/17/2021 1:21:38PM Page 7 Hydraulic Calculations for Project Name: ARGONAUTA RESIDENCE Location: 2700 ARGONAUTA ST. CARLSBAD, CA 92009,, Drawing Name: ARGONAUTA RES 20-0447 Calculation Date: 6/17/2021 Design Remote Area Number: Remote Area Location: UNIT Occupancy Classification RESI 2HD Density Area of Application.- Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.050gpm/ft2 512.00ft2 (Actual 141 .79ft2) 256.00ft2 Pendent 2 0 N/A gpm at Node: N/A 0.0 gpm at Node: I Type 5.00 at Node: 5 Type Allowance at Source Hose (Safety Margin = 13.175) Total Water Required (including Hose Streams where applicable).- From Water Supply at Node 1: 31.09 @49.219 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: KW BUILDING Address: 1460 ORPHEUS. ENCINITAS, CA 92024, Phone Number: Name of designer: CHRISTIAN MENDOZA Authority Having Jurisdiction: CARSLBAD FIRE DEPT. Notes: Automatic peaking results Left: N/A Right: N/A (M.E.P.CAD, Inc. AutoSPRlNK 2020 06.3.4.0 1 6/17/2021 1:22:09PM Page 1 500 oo 700 Flow - gpm 800 900 1000 Hydraulic Graph N 1.85 Date: 6/17/2021 Water Supply Summary Sheet Node: I Available Static Pressure 1.09 0 Supply 62.400 kO.00 61.400 62.394 - '1.09t49.219— System demand curve IllIllIll 111111111 111111111 11111 liii II I liii 11111 I I I I I I I I I I (,© M.E.P.CAD, Inc. h] AutoSPRINK 2020 06.3.4.0 6/17/2021 1:22:11PM Page 2 9C 8C 7C 6C 3C 20 ic Job Name: ARGONAUTA RESIDENCE Remote Area Number: 1 100 1111111111111111 111 5C 0 0 R jSummary Of Outfiowing Devices Job Number 200447 Report Description: RESI 2HD (1) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hose 5 5.00 5.00 0 17.351 c Sprinkler 101 13.00 13.00 4.9 7.039 Sprinkler 102 13.09 13.00 4.9 7.140 c Most Demanding Sprinkler Data &©M.E.P.CAD, Inc. AutoSPRlNK202006.3.4.0 6/17/2021 1:22:12PM Page Job Name: ARGONAUTA RESIDENCE emote Area Number: 1 Date: 6/17/2021 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 62.400 61.400 500.00 62.394 J 31.09 49.219 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1 517-11% Supply 49.219 31.09 5 520-5% 17.351 5.00 101 527-0 Sprinkler 7.039 13.00 102 527-0 Sprinkler 7.140 13.09 2 520-11% 40.526 3 520-11% 21.167 4 516111/2 20.442 6 520-11% 15.992 7 527-6 8.889 8 527-6 8.738 10 527-6 7.456 11 527-6 7.286 12 527-6 7.239 ,©M.E.P.CAD, Inc. lflAutoSPRINK 2020 06.3.4.0 6/17/2021 1:22:15PM Page 4 Job Name: ARGONAUTA RESIDENCE Remote Area Number: 1 Date: 6/17/2021 Pipe Information Node 1 Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices E Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit ( Elev(Pe) Node 2 Elev2 00) Total Flow Actual ID Total (Foot) Friction(Pf) 101 527-0 13.00 i (See N o es, 51u/2 150 7.039 Route I ..... Sprinkler, E(5'-O), 1(5-0) o o 0.030666 -0.217 11 527-6 13.00 1.1010 15-1% 0.464 11 527-6 ]49 3.70 1 351/2 150 7.286 Flow (q) from Route 2 0048738 10 5276 1670 11010 0.170 10 527-6 i (See Notes) 61'-3% 150 7.456 E(5'-O), 1(5-0) 10-0 0.020101 7 527-6 10.35 1.1010 71-3% 1.433 7 527-6 15.75 1 (See Notes) 1541/2 150 8.889 Flow (q) from Route 3 2E(5-0), 2f, 3Tr(1-0), CV(5'-O), 23-0 0.111289 2.830 6 520-11% 26.09 1.1010 38-4% 4.273 6 520-11% 1 (See Notes) 0'6 150 15.992 T(6'-9) 6-9 0.157664 0.217 5 520-5% - . 26.09 1.0250 1.142 5 520-5% 5.00 i (See Notes) 4'6 150 17.351 E(2'-8%) 28h/2 0.218065 1.522 4 516-11% 31.09 1.0250 7'2 % 1.570 4 516-111/2 11/2 (See Notes) 71'0 150 20.442 3E(9 0) 27-0 0025084 -1.734 3 520'-11Y2 31.09 1.5980 98 0 2458 3 520-11% 1 (See Notes) 7'3% 150 21.167 3E(2'-8%), BFP(-12.000), WMV (-4.000) 8-1 0.218065 2 520-11% 31.09 1.0250 15-5 19.359 2 520-11% i (See Notes) 27'0 150 40.526 E(2-4), S 2-4 0.252007 1.301 1 517-11% 31.09 0.9950 29-4 7.393 0.00 49.219 Hose Allowance At Source Total(Pt) Route 1 1 31.09 102 527-0 4.9 13.09 1 (See 5'l% 150 7.140 ••"• Route 2..... E(5'-O) 5-0 0.031076 Notes)Sprinkler, -0.217 12 527-6 13.09 1.1010 10-1% 0.315 ,©M.E.P.CAD, Inc. is AutoSPRINK2020v16.3.4.0 1 6/17/2021 1:22:17PM Page Job Name: ARGONAUTA RESIDENCE Remote Area Number: 1 Date: 6/17/2021 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, Elev 2 Total Flow Loss Per Unit when applicable, are added Total Friction(Pf) Node 2 (Foot) (Q) Actual ID Length (Foot) (psi) directly to (Pf) and shown as (Foot) 12 527-6 i (See 101 10 150 7.239 T(5'-O) 5-0 Notes) 11 527-6 - 3.70 1.1010 0.002999 5-10 1 0.047 7.286 Total(Pt) Route 2 10 527-6 i (See 106'3 150 7.456 Route ..... 51-0 T(5'-O) Notes) 8 527-6 6.35 1.1010 0.008155 5E(5-0), 21(5-0), 2C(5-0), 157-3 1.282 cplg(1-0) 8 527-6 9.39 1 3-51A 150 8. 738 Flow (q) from Route 4 0.043722 7 527-6 15.75 1.1010 351/2 0.151 8.889 Total(Pt) Route 3 12 527-6 370 1 (See 74-2 150 7.239 Route 4••••• Flow (q) from Route 2 15-0 Notes) 8 527-6 9.39 1.1010 0.016813 1(5-0), 2E(5-0) 89-2 1.499 8.738 Total(Pt) Route 4 (/,©M.E.P.CAD, Inc. Ifi AutoSPRINK202Ov16.3.4.O 1 6/17/2021 1:22:17PM Page Job Name: ARGONAUTA RESIDENCE Remote Area Number: 1 Date: 6/17/2021 lEquivalent Pipe Lents of Valves and Fittings (C=120 only) IC Value Multiplier I Actual Inside Diameter 4.87 =Factor Value Of C 100 130 140 150 1 \ Schedule 40 Steel Pipe Inside Diameter ) Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve ArigV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 900 Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. J1 AutoSPRlNK2020v16.3.4.0 1 6/17/2021 1:22:17PM Page Technical Specifications Style: Flat Concealed Pendent Threads: 112° NPT or ISO 7-1R1/2 Nominal K-Factor. 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mitt. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Season Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass May Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper May Pins: Stainless Steel Deflector Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating Ordinary. 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC cover plate Sprinkler Wrench Model PC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULts Listed to lii 1625 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threads Body - Cup - Tower Fusible Link - Deflector (retracted) Pin (extended) Deflector (extended) - 1-3/4 (44 mm) +1- 1/4° (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate _ 3/16'(6 mm; Ceiling Model RFC40 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure") Max. Coverage Area Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft x ft (mxm) gpm psi gpm psi (I/mm) (bar) (1/mm) (barj 16x 16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0,48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5x5.5) (64.3) (0.83) (643) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1,15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow l i s t e d in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq It over the design area of t h e s p r i n k l e r . For coverage area dimensions less than those listed above, use the minimum r e q u i r e d f l o w f o r t h e n e x t l a r g e r m a x , c o v e r a g e a r e a l i s t e d . Bulletin 006 Page 4o1 8 May 2019 www.reliablesprinkIer.com Cover Plate Finishes(') Standard Finishes Special Application Finishes L White Polyester Off White Paint Black Paint Raw Brass L Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad'3 Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on t h e b a c k s i d e . C o v e r p l a t e s are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perf o r a t e d . Installation Dimensions Min.to Min.to Max. 7=9' RecommendedCover Cover Plate Dropped DeflectorSprinkler Cover Plate Max. Face Plate Hole DiameterMOdei Diameter in Ceiling Adjustment of Fitting to Distance below Model Inch (mm) Inch (mm) Inch (mm) Ceiling") Ceiling Rating inch (mm) inch (mm) RFC30, RFC 3-5/16 2-5/8 IN 1-1/2to2 1/2to1 135°F RFC30LL (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 1350F2' RFC43LL, RFC 3-5/16 2-5/8 1/2 1-1/2t02 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 165°F3 RFC49LL (74°C) 135°F2) RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 1650P3 I (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based o n f i t t i n g a n d t h r e a d s e a l i n g m e t h o d prior to installation. A 112' x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary f o r r e p l a c e m e n t o f e x i s t i n g sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not e x c e e d 1 0 0 ° F ( 3 8 0C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exc e e d 1 5 0 ° F ( 6 6 ° C ) . Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protec- tive cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed us- ing the Model FC wrench by temporarily removing the protec- tive cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permit- ted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engag- es the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler Into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4° thread sprinklers. Bulletin 006 May 2019 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting.or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until ft is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprin- klers are available in either ordinary or intermediate tempera- ture classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com FV J) Model FC Model W3 For use with Model RFC Series sprinklers For use with Model RFC Series sprinklers without wrench-able cap installed with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Ustings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC3OLL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 Page 8 of 8 May 2019 Malmo www.retiablesprinkler.com Bulletin 135 October 2018 MGM CNL;NCtI Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed For NFPA 13, NFPA 13R, and NFPA 13D Applications Features $ cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element, A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The Fl Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 130. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13A, or NFPA 13D. For NFPA 13R and NFPA 130 applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Residential Sprinkler Summary Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Sprinkler Sprinkler Identification Orientation K-Factor gpmlpsi"2 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (Ipm/bar11) NPTorlSO7-1 ftxft(mxm) F1JRes30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) .F1Re09 P3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) FiRes58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20x20(6.1 x6.1) FiRes76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20x20(6.1 x6.i) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14(4.3 x 4.3) F1Res49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res58CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res76CCP P7618 Pendent 7.6(109) 314 Conical Concealed or Recessed 20x20(6.1 x6.1) Fl Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20 (4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x6.1) F1Res58 HSW P3533 Horizontal Sidewall 6.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) FiRes 58 HSWX RA3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 14 x 26(4.3 x 7.9) www.reliablesprinkler.com Fl Recessed Escutcheon Installation F2 & Pd Recessed Escutcheon Installation 1-58" (41MM) 4/- 3/8" (9mm) 2-7/8" (72mm) DIA. 7/8" (72mm) DIA. -- Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2k NPTor 807-1 RI/2 Temperature Ratings Nominal K-Factor: 4.9(71 metric) 155F (68CC) (, Max. Working Pressure 175 psi (12 bar) 175-F (79-C) Material Specifications Thermal Sensor: 3 mm glass-bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed F2 Recessed Button: Copper Alloy FV Recessed Sealing Assembty Nickel Alloy with PTFE Load Screw; Bronze Alloy Sprinkler Wrenches Deflector. Bronze Alloy Model W2 Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions - 2-1/4 (57mm) 2-1/4" (57mm) U(49mm) Face of hiting 01k T Face of fitting +1- 3/8" (9mm) +1- 1/4" (6mm) to finished to finished 5/8 (16mm) 1/2" (13mm) ceiling (49mm) DIA. ceiling F 0MV _ 2-1/4 (57) L 1-1/4" (32mm) Dimensions Model Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Arean ft. x ft (mx m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0(0.48) 1 t 4 Inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13(49) 7.0(0.48) 18x 18 (5.5 x 5.5) 17 (64) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15 (57) 9.4 (0.65) to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20x20(6,1 x6.1) 22(83) 20.2(l.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow r e q u i r e d t o achieve a minimum design density of 0.1 gprnlsq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max . c o v e r a g e a r e a l i s t e d . Bulletin 135 Page 3 of 15 October 2018 www.reliablesprinkIer.com Model GFR2 Finishes Standard Finishes Special Application Finishes Sprinkler(l) Fl, F2. FV FIRM, CCP, SWC (Conical) Spnnkler Fl, F2. FV 3' FP, CCP, SWC (Conical) Escutcheons Cover Plates Escutcheons Cover Plates t Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester (2)Polyester Polyester (2)Polyester -- -- Custom Color Custom Color Custom COlor Paint -- Polyester Polyester Electroless Nickel -- -- PTFE'21 -- -- Notes: - Paint or any other coating applied over the factory finish will void all approvals and w a r r a n t i e s . cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finishe d e s c u t c h e o n r i n g . Installation Models F1 Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use With individual sprinklers, Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model W2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8' (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and 'Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and lS07-1R1/2: 8-18 ft-lbs (11 -24 N-m) 3/4" NPT and 1S07-1R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 Page 14 of 15 October 2018 www.rellablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www,r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPTor lS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) 2: Bulletin135 Page 15 of 15 October 2018 rMen,2111 www.reliablesprinkler.com ttiul$elifl 014 Marcfl 2U1 -i-----r__ Ak "1 Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendant Horizontal Sidewall Model F1 FR56 Concealed Sprinkl e r T y p e s Standard Spray Pendent Model F1FR42, F1FRXLH & FIFR28 S p r i n k l e r Types Standard Spray Upright Standard Spray Pendent Model FIFR40 Sprinkler Types Standard Spray Pendant Model FIFR4Z FIFR40, FIFRXLH & FIFR28 Recessed Sprinkler Types Standard Spray Pendent Model FIFR5SLL & Fl R42..L Low Lead Sprinkler TAM Standard Spray Pendant with less th a n 0 . 2 5 % L e a d Content Listing & Approvals The following organizations provide Listi n g s o r A p p r o v a l s for various Model F1FfR series sprinklers . S e e t h e D e s i g n and Installation table in this Bulletin for i n f o r m a t i o n o n specific listings and approvals applica b l e t o e a c h s p r i n - kler. Underwriters Laboratories Inc. an d C e r t i f i e d f o r Canada (cULus) in accordance with A N S I I U L 1 9 9 . FM Approvals (FM) Loss Prevention Certification Board (LP C B ) VdS SchadenverhUtung GmbH (VdS) Underwriters Laboratories Inc. and U n d e r w r i t e r s Laboratories of Canada Certified for H e a l t h E f f e c t s to NSF/ANSI Standard 61 Annex G (UL H ) EC Certificate: 0786-CPD-40239 (BA 1 4 1 4 ) , 0 7 8 6 - CPD-40251 (RA1 425), 0786-CPD-402 5 2 ( R A 1 4 7 5 ) (EC) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Upright Pendant Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentdF1,F2 Recessed Concealed Recessed Horizontal Sidewall Pendent PendenljFP XLH Upright XLH Pendant XLH Recessed Pendant F11F2 Product Description Reliable Model Fl FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. "•- Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventiona l X L H R e c e s s e d sprinkler which is an Old-style/Conven- Pendant FP tional sprinkler. The Model Fl FR Series automatic sprinkler s u t i l i z e a 3 . 0 mm frangible glass bulb. These sprinklers h a v e d e m o n s t r a t - ed response times in laboratory tests w h i c h a r e l i v e t o t e n times faster than standard response sprin k l e r s . T h i s q u i c k response enables the Model Fl FR Series s p r i n k l e r s t o a p p l y water to a fire faster than standard-response s p r i n k l e r s o f t h e same temperature rating. The glass bulb consists of an accurately co n t r o l l e d a m o u n t of special fluid hermetically sealed inside a p r e c i s e l y m a n - ufactured glass capsule. This glass bul b i s s p e c i a l l y c o n - structed to provide fast thermal respons e . Elmsford, New York 10523 Reliable Automatic Sprinkler Co., I n c . , 1 0 3 F a i r v i e w P a r k D r i v e , in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Ft FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model COP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model Fl FR5SLL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model COP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model Fl FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembt care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the ptective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model COP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. iechnical Data: Sensitivity Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-A 1 / 2 o p t i o n a l Maximum Working Pressure: 175 psi (12 bar)- 100% Factory teste d h y d r o s t a t i c a l l y t o 5 0 0 p s i ( 3 4 . 5 b a r ) SIN RA1425, RA1414 & RA1 4 3 5 c U L u s l i s t e d f o r 2 5 0 p s i ( 1 7 b a r ) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler JeIg ____ Installation Wrench Approvals Listings Listings and Approval Notes US Metric inches mm inches - mm F1 F828 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GF82 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 225 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2,26 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7116 10 Pendent 2.25 57 W2 RA14I0 cULus, ULH Recessed Pendent 2.25 - 57 GFR2 RA14I0 cULus, ULH Fl FRXLH (F1FR42 with Pintle) 4.2 - 60 7/16 10 - Pendent 225 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1F856 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VcJS, EC 1,2,3,4 Concealed Pendent 2.25 57 GFR2 RA14141 cULus,VdS,EC 516 Upright 2.25 57 W2 RA1425 cULus, FM, LPGB, VdS, 1,2,3,4 'Conventional (Pendent or Upright) 2.25 57 W2 RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 225 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 225 57 GFR2 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2,63 67 GFR2 RA1435 cULus, FM 8 5.6 80 1/2 15Vertical Sidewall (Pendent or Upright) W2 IRA14851 F1FR56 25 57 2.cULus, FM, LPCB 112,319 11) cULus Listed Corrosion Resistant sprin k l e r w h e n o r d e r e d w i t h a v a i l a b l e P o l y e s t e r c o a l i n g . cULus Listed Corrosion Resistant sp r i n k l e r w h e n o r d e r e d w i t h a v a i l a b l e E l e c t r o t e s s N i c k e l P T F E p l a t i n g . 131 Available with FM approved Polyeste r c o a t i n g i n b l a c k o r w h i t e . 11) Available with LPCB and VdS approve d P o l y e s t e r c o a t i n g . 01) VdS and EC approvals of the FIFR51 6 C o n c e a l e d P e n d e n t s p r i n k l e r a r e f o r 1 5 5 ° F ( 6 6 ° C ) t e m p e r a t u r e r a t e d s p r i n k l e r s o n l y . V d S a p p r o v e d s p r i n - klers must use Norbuib brand glass b u l b s w i t h t h e 1 / 2 - i n c h ( 1 2 . 7 m m ) a d j u s t m e n t M o d e l O C R c o v e r p l a t e o n l y . ' Model F1FR56 Concealed Pendent a n d M o d e l F 1 F R 6 6 L L C o n c e a l e d P e n d e n t s p r i n k l e r s m u s t b e u s e d w i t h R e l i a b l e M o d e l C O P c o v e r p l a t e s , available as either standard depth w i t h 1 / 2 - i n c h ( 1 2 . 7 m m ) o f a d j u s t m e n t o r l o w p r o f i l e w i t h 5 / 1 6 - i n c h ( 8 . 0 m m ) o f a d j u s t m e n t . ° cULus Listing of the FIFR56 Hori z o n t a l S i d e w a l l s p r i n k l e r i s f o r L i g h t a n d O r d i n a r y H a z a r d o c c u p a n c i e s o n l y . M i n i m u m t o m a x i m u m d e f l e c t o r t o ceiling distance shall be 4 inches to 1 2 i n c h e s ( 1 0 2 m m t o 3 0 5 m m ) . F M A p p r o v a l o f t h e F 1 F R 5 6 H o r i z o n t a l S i d e w a l l s p r i n k l e r i s f o r L i g h t H a z a r d occupancies only. B cULus Listing and FM Approval of t h e F 1 F R 5 6 R e c e s s e d H o r i z o n t a l S i d e w a l l s p r i n k l e r i s f o r L i g h t H a z a r d o c c u p a n c i e s o n l y . The F1FR56 Vertical Sidewall sprinkler i s l i s t e d a n d a p p r o v e d f o r u s e o n l y i n L i g h t H a z a r d o c c u p a n c i e s . L P C B a p p r o v a l o f t h e F 1 F R 5 6 V e r t i c a l Sidewall sprinkler is for installation in t h e P e n d e n t p o s i t i o n o n l y . Usted and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification 100°F (38°C) Max. Ambient 150°F (65°C) Max. Ambient 225°F (107°C) Max. Deflector/ Model i,uOfl orie V. Temp. Ambient Temp. 135°F (57°C) I 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Temp. Temp. Rating I Temp. Rating1 Temp, Rating Temp. Rating 1 Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendant cULus Fl FR2B Recessed Pendent cULus I Upright cULus Pendant VdS FIFR40 Recessed Pendant VdS I Pendent cULus FIFR42 Recessed Pendent cULus Upright cULus Pendant • cULus ULH F1FR42LL Recessed Pendent cULus ULH Pendent cULus FIFRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB VdS EC Concealed Pendent cULus I cULus VdS EC I cULus F1FR56 Upright cULus, FM, LPCB, VdS, EC 'Conventional LPCB VdS EC (Pendant or Upright) Pendent cULus, ULH ... . ' FIFR66LL Recessed Pendent cULus. ULH °t:' Concealed Pendent* -. . ..'-..: ..' .'':' - cULus, ULH Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal cULus FM Sidewall ' Fl FR56 i Vertical Sidewall (Pen- cULus, FM, LPCB dent or Upriaht) * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Usted and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model (Fig. 1 & 3) (Fig. I & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment FIFR28 I RecessedPendent cULus cULus cULus RA141 1 F1FR40 RecessedPendent VdS VdS VdS RA1418 FIFR42 RecessedPendent cULus cULus cULus RA1413 FIFR42LL RecessedPendent cULus,ULH cULus,ULH cULus, ULH RA1410 F1FR42XLH RecessedPendent cULus cULus cULus RA1413 FIFR56 Recessed Pendant cULus, LPCB, VdS, cULus, FM, LPCB , cULus, VdS, EC RA1414 EC VdS,EC FIFR56LL Recessed Pendent cULus,ULH cULus,ULH cULus, ULH RA1415 FIFRSB RecessedHorizontalSidewall cULus cULus,FM cULus RA1435 TURN COLLAR UNTIL TiGHT AGAINST SPRINKLER WRENCH 805S ELISCUTCHEONI 07 ADJUSTMENT F2 ESCUTCHEON 1/2712.7mmJ ADJUSTMENT 2 1/4 HOLE D14 [7.2mm] - 15/16 014 [49.2mm) r 1 \ If 7 X 2/2 REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION fJ5UTCHEON Al MAXIMUM RECESS 7725.4mm ] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4[19mm] 77Z/771 _TAT MINIMUM RECESS 3/879.5 m m ] Fl ESCUTCHEON . J ¶ AT MAXIMUM RECESS 7/8'[22.2m m 3 (Zmm) I / AT MINIMUM RECESS = 1-5/874 73mm] F2 FSCUTChfFQN AT MAXIMUM RECESS = 1-1/8728.6mm] AT MINIMUM RECESS = I -5/8741.3mm] 2 27/32- 0/A (72.2mm) Model F1FP56, F1FR56LL, F1FR42, F1FR40, FIFR42L L , F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F l o r F 2 e s c u t c h e o n x 1/2' REDUCER 2 5/8k DIA. [66.7mm) HOLE IN CEILING 2 5/16 DU. [58.7mm] CUP CEILING FACE OF FITTING To FACE OF CEILING DIMENSION AT MAX/MUM RECESS = 1- 7/2[38mm] AT MINIMUM RECESS 1725.4mm] Y2712.7mrn) J I AT MAXIMUM RECESS = 9/16714.3mm) AT MINIMUM RECESS 1725.4mm] ADJUSTMENT ___ 31/eDIA. $ [82.6mm] Model F1FR56, F1FR56LL, F1FR42, F1F R 4 0 , F I F R 4 2 L L F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F P e s c u t c h e o n 5. 2 5/16" 0/A - CUP -.. CEILING FACE OF fliT/NC TO FACE OF CEILING DIMENSION F! ESCUTCHEON AT MAXIMUM RECESS = 1725.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] 2 1/4" HOLE 0/A. [5Z2mrn] [3.2mm] Fl ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mmJ AT MINIMUM RECESS = 2- 1/16752.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8 "[41.3mm] AT MINIMUM RECESS = 2-1/16752.4mm] 1 X 1/2" REDUCER 1 15/16" O14.4j,..4 I49.2mmJ 2 27/32" 0/A. [72 .2mm] V (1) 4"-12" [101. 6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT RECESSED HSW w/F1 OR F2 ESCUTCHEON (i) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 5/8" DIA. HOLE IN CEILING 4 1 1/2" MAX. FACE OF FITTING JTO_FACE OF CEILING DIMENSION 112 " MAX 15/16 COVER ADJUSTMENT " COVER PLATE ASSEMBLY .- 3 5/16 DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Mode? CCP cover plate 1" x 1/2' REDUCING TEE OR ELBOW 2 5/16" DIA - Cup /1 if/I CEILING 5/16" MAX. COVER ADJUSTMEN COVER PLATE —1---' ASSEMBLY 5/16" 0/A. SPR/NKL ER - Z VIA HOLE IN CEILING 1 1/2 MAX, FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" CONCEALED. 5/16" ADJUSTM E N T Fig. 5- Model F1FR56JF1FR56LL Conce a l e d P e n d e n t s p r i n k l e r with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers s h o u l d b e i n s p e c t e d a n d the sprinkler system maintain e d i n a c c o r d a n c e w i t h N F P A 25. Do not clean sprinklers with s o a p a n d w a t e r , a m m o n i a o r any other cleaning fluids. Rem o v e d u s t b y u s i n g a s o f t b r u s h or gentle vacuuming. Replace an y s p r i n k l e r w h i c h h a s b e e n painted (other than factory appli e d ) o r d a m a g e d i n a n y w a y . A stock of spare sprinklers s h o u l d b e m a i n t a i n e d t o a l l o w quick replacement of damaged o r o p e r a t e d s p r i n k l e r s . Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platen) Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated "w White Painted Special Application Finishes Sprinkler Escutcheon Cover plate(l) Electroless Nickel PTFE'' Electroless Nickel PTFE grass Bright Bright Brass(3) Bnght Brass Black Plating Black Plated Black Plated Black Paint Black Paint(20) Black Paint Off While Off Whtte 6) I Off White Satin Chrome Chrome Dull I Chrome Dull I '4 Other finishes and colors are av a i l a b l e o n s p e c i a l o r d e r . C o n s u l t t h e factory for details. Custom color painted sprinklers may not retai n t h e i r UL Corrosion resistance listing. C o v e r p l a t e c u s t o m p a i n t i s s e m i - g l o s s , unless specified otherwise. 2) cULus Usted only. ' 200°F (93°C) maximum. '4' cULus listed 'corrosion resistan c e " a p p l i e s t o S I N N u m b e r s A M 4 3 5 (i-ISW), RA1485(VSW), RA1425 ( U p r i g h t ) , R A 1 4 1 4 ( P e n d e n t ) a n d RA1415 (Pendent) in standard black or white. Corrosi o n r e s i s t a n c e i n other polyester odors is available upon request. "4 FM Approvals finish as "Polyester coated' applies to SI N N u m b e r RA1414, RA1435 and RA1425 in standard black or white. (r1p08 and VdS Approved fini sh applies only to RA1425, RA1414, R A 1 4 1 8 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, OM Brass, or Low Lea d B r a s s Deflector: CDA Alloy 2204 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer. Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FA28][F1 F R 4 O } [ F 1 F R 4 2 [Fl FR42LLJ[Fl FRXLH][F1 FR56 ] [ F 1 F R 5 6 L L ] Sprinkler Deflector/Orientation : [ P e n d e n t ] [ R e c e s s e d Pendent][Upright][Conventiona l ] [ H o r i z o n t a l S i d e w a l l ] [Recessed Horizontal Sidewallj ( V e r t i c a l S i d e w a l l ] Sprinkler threads: [1/2-inch NP T ] [ l S O 7 - R 1 / 2 1 Sprinkler Temperature Rating: [ 1 3 5 ° F ( 5 7 ° C ) J [ 1 5 5 ° F (68°C)][ 175°F (79°C)][200°F ( 9 3 ° 0 ) ] [ 2 8 6 ° F ( 1 4 1 -C)] Sprinkler Finish Escutcheon Model: [F1J[F2J[FP J Escutcheon Finish (where ap p l i c a b l e ) Cover plate Model: (standa r d p r o f i l e C C P 1 / 2 - i n c h (12.7mm) adjustment)[ low p r o f i l e C C P 5 / 1 6 - i n c h (8.0mm) adjustment] Cover plate Temperature Ra t i n g : [ 1 3 5 ° F ( 5 7 ° C ) f o r u s e with Ordinary Temperature sp r i n k l e r s ] [ 165°F (74°C) for use with Intermediate Tem p e r a t u r e s p r i n k l e r s ] Cover plate Finish Nate: When Model F1FR Series R e c e s s e d s p r i n k l e r s are ordered, the sprinklers and escutcheons are p a c k a g e d s e p a r a t e t y. 7. nefiaWe .. For Complete Protectiol Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers 0 Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves 0 Accelerators for dry pipe valves 0 Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves 0 Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards 0 Inspectors test connections ° Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431 -1588 Sales Offices 0 Paper R41"hilab (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices i www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 pflj 9999g7Q3Q "TcRediRressureign-i le,IU)M.W an 00 4sse.rnI51y t FEATURES Sizes: U 3/4" U 1" U 1 1/4" U 1 1/2" U 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 OPTIONS (Suffixes can be combined) U - with full port OT ball valves (standard) U L - less ball valves U U - with union ball valves U MS - with integral relief valve monitor switch U P - for reclaimed water systems U S - with bronze "Y" type strainer U BMS - with battery operated monitor switch o FDC - with fire hydrant connection; 2" only U TCU - with test cocks up U V - with union swivel elbows (3/4" & 1") U SE - with street elbows U FT - with integral male 450 flare SAE test fitting ACCESSORIES U Air gap (Model AG) U Repair kit (rubber only) 0 Thermal expansion tank (Model XT) 0 Soft seated check valve (Model 40XL) U Shock arrester (Model 1250) U 01-SET Quick Test Fitting Set 0 Ball valve handle locks U Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. STANDARDS COMPLIANCE ASSE® Listed 1013 IAPMO® Listed UL® Classified (less shut-off valves or with OS&Y valves) C-UL® Classified CSA® Certified AW\NA Compliant C511 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA 425-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASIM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers NoryiM, NSF Listed Springs Stainless steel, 300 series E .. \. i.- if F •' . '--.. n, D H -- - C H B - -A C Relief Valve discharge port: 3/4" -1 - 0.63 sq. in 11/4 -2' - 1.l9 sq. in. DIMENSIONS (approximate) WEIGHT MODEL LESS WITH SIZE A A UNION B LESS BALL C D B F G BALL BALL BALL VALVES VALVES VALVES VALVES in. mm in. mm in. I mm in, mm in, I mm in, mm in. I mm in mm in. mm lbs I kg lbs. I kg 3/4 20 12 305 13314 349 73/4 197 2 1/8 54 3 76 31/2 89 5 127 161/8 410 10 14.5 12 1 5.5 1 25 13 330 141/2 368 73/4 19728 54 3Th3 1/2 89 5127 173/8 44110 4 14 6A 11/4 32 17 432 18 13/16 478 10 15/16 278 23/4 70 31/2 89 5 127 63/4 171 229/16 573 22 10 28 12.7 11/2 40 173/8 441 193/8 492 10 15/16 278 23/4 70 31/2 89 5 127 63/4 171:241,116 611 22 10 28 12.7 2 50 181/2 470 201/2 521 1015/16 278 23/4 70 31/2 69 5 127 63/4 171 261/2 673 22 10 34 15.4 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1 -877-222-5356) Website: http://www.zurn.com 0 U) 0 t 314"I20rnM'____ ____1"(2_ : f_ 1T31 5 20 15 10 137 '- U) Co 103 £ 12 MIN 30" MA) AIR GAP DRAIN \ D'NECTIOU OF FLOW 1.26 FLOW CHARACTERISTICS MODEL 975XL 3/4", 1', 1 1/4", 11/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 W.0 0 'o so FLOW RATES (GPM) O Rated Flow (Established by approval agencies) a 35 Ir 100 150 200 250 TYPICAL INSTALLATION Local codes shall govern installation require- ments. To be installed in accordance with the manufacturers instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12' (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 6 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4' 2 2 3 5 3/8" 3 1 4 6 9 1/2' 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 11/4' 23 35 47 70 1 1/2' 32 48 63 95 52 78 105 167 Li2J rTL STATION ALARM -. 1 PANEL MONI & . FOR I SWITH / 12" MIN JO MAX f -AIR J7 II I PITTING L 'm- FLOOR- -. - - FLOOR DRAIN PROTECTIVE ENCLOSURE OPT tONAL ,ATER ME 1 ER II? . INLET SHUT-OFF DIRECTION OF FLOW r. INDOOR INSTALLATION OUTDOOR INSTALLATION - (Showi i oslional EMS) SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180CF and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all in t e r n a l polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. I f i n s t a l l e d indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The R e d u c e d P r e s s u r e Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a Zurn company, 1747 Commerce Way. Paso Robles. CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga. Ontario L4V 11_2 Phon e : 9 0 5 / 4 0 5 - 8 2 7 2 F a x : 9 0 5/405-1292 Product Support Help Line: 1-877-BACKFLOW(1-877-222-5356) - Website: http://www.zurn.com Page 2 of 2