HomeMy WebLinkAboutCDP 2021-0026; PAVAGADHI ADU; Administrative DeterminationABBREVIATIONS• A.B. ANCHOR BOLT ABV. ABIJVE A.F.F. ABOVE FINISH L A/C ALT. ARCH. B.F. BLDG, BLKD. BLKG, BL'vJ, BM. B.N. FLOOR ANGLE AIR CONDITIONING ALTERNATE ARCHITECTURAL BRACED FRAME BUILDING BLOCKED BLOCKING BELO'w BEAM BOUNDARY NAILING . B.O.F. BOTTOM OF FOOTING BEARING BOTTOM BET'vJEEN CAST IN PLACE CONSTRUCTION JDINT BRG. BTM. BT'vJN. C.I.P, C.J. CL CLG. CLR. C.M.U. COL. CONC. CONN. CONST. CONT, C.S.K. DBL. DIAG. D'vJG, D'vJL. (E) EA. ELECT. ELEV. EMBED. E,N. E.S. E.'vJ. EXIST. EXT. FIN. FLR. F.N. FLR FND. F.O. F.O.C. CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS COUNTERSINK DOUBLE DIAGONAL DRA'w!NG DO'vJEL EXISTING EACH ELECTRICAL ELEVATION EMBEDMENT EDGE NAILING EACH SIDE EACH 'vJAY EXISTING EXTERI□R FINISH FLOOR FIELD NAILING FLOOR FOUNDATION FACE OF FACE OF CONCRETE F .O.M. FACE OF MASONRY F.P. FRMG. FTG. F.V. GA, GALV. G.L.B. GRD. HORIZ HDR. HGR, Hll, H.D.G. FULL PENETRA TIIJN FRAMING FDDTING FIELD VERIFY GAGE GALVANIZED GLUE LAMINATED BEAM GRADE HORIZONTAL HEADER HANGER HOLDO'vJN HOT-DIPPED GALVANIZED HGT. HEIGHT HS.B. HIGH STRENGTH BOLT INT. INTERI□R JT, JDINT JST. JOIST LBS. POUNDS LG, LONG LT. 'vJT. LIGHT 'vJEIGHT MAX. MAXIMUM M.B. MACHINE BOLT MECH. MECHANICAL MIN, MINIMUM MTL. METAL (N) NE'w NLG. NAILING 0/C. ON CENTER OPNG, OPENING cl PENNY P.C.C. PRE -CAST PL. PL'vJD, P.T. R'vJD. REIF. REQ'D. REF. REINF. SCHED, SHT'G. SIM. SMS. CONCRETE PLATE PLY'vJOOD PRESSURE TREATED RED'w□OD REINFORCED REQUIRED REFERENCE REINFORCING SCHEDULE SHEATHING SIMILAR SHEET METAL SCRE'w S.□.G. SLAB ON GRADE SPEC, SPECIFICATIONS SQ, SQUARE STIFF. STIFFENER STOR STORAGE STL. STEEL STRUCT. STRUCTURAL T8.B. TOP AND THRD, TEMP. TS. TYP. U.O.N. BOTTOM THREAD TEMPORARY TUBE STEEL TYPICAL UNLESS OTHER'vJISE NOTED VERT, VERTICAL V.I.F. VERIFY IN FIELD 'vJITH 'vJOOD 'vJEIGHT 'vii 'vJD. 'vJGT. GENERAL NOTES• THE CONTRACTOR AND/OR SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS ON THE DRA.',/INGS AND SHALL NOTIFY THE O',/NER AND DESKIN BUILDING OF ANY DISCREPANCIES, PRIOR TD STARTING THEIR ',/ORK. THE CONTRACTOR AND/DR SUBCONTRACTORS ',/ORK SHALL CONFORM TD ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES. EACH SUBCONTRACTOR IS CONSIDERED A SPECIALIST IN HIS FIELD AND SHALL• PRIOR TD THE SUBMISSION OF BID DR PERFORMANCE OF ',/ORK, NOTIFY THE GENERAL CONTRACTOR AND O',/NER OF ANY ',/ORK CALLED OUT ON THE DRA',/JNGS PERTAINING TO HIS TRADE THAT CANNOT BE FULLY GUARANTEED. THE CONTRACTOR AND/DR SUBCONTRACTOR SHALL BE RESPONSIBLE FDR THE APPROPRIATE 'HOOKUP' TD ALL UTILITIES REQUIRED TD COMPLETE ',/ORK. ',/HERE CONSTRUCTION DETAILS ARE NOT SHO',/N DR NOTED FDR ANY PART OF THE ',/ORK, THE DETAILS SHALL BE THE SAME FDR OTHER SIMILAR ',/ORK AND MUST C□MPL Y ',/ITH THE 2016 CBC. ANY EXISTING SMOKE ALARMS THAT ARE MORE THAN 10 YEARS OLD ',/ILL BE REPLACED. SECTION R314.3.2. THE INSPECTOR ',/]LL RECHECK FDR EXPANSIVE SOILS AND/OR GRADING REQUIREMENTS AT THE FIRST FOUNDA TI□N INSPECTION. THIS PROJECT ',/ILL COMPLY ',/ITH THE COUNTY OF SAN DIEGO LIGHTING ORDINANCE. THE CONTRACT STRUCTURAL DRA',/INGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS □THER',/ISE INDICATED, THEY DD NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TD PROTECT THE STRUCTURE, ',/ORKMEN, AND OTHER PERSONS DURING CONSTRUCTION, SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TD, BRACING, SHORING FDR CONSTRUCTION EQUIPMENT, SHORING FOR THE BUILDING, SHORING FDR THE EARTH BANKS, FORMS, SCAFFOLDING, PLANKING, SAFETY NETS, SUPPORT AND BRACING FDR CRANES AND GIN POLES, ETC, THE CONTRACTOR SHALL SUPERVISE THE ',/ORK AND HE SHALL BE SOLELY RESPONSIBLE FDR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, OBSERVATION VISITS TD THE SITE BY DESKIN BUILDING DESIGN DR THE ENGINEER, SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS, THESE DRA',/INGS SHO',/ □NL Y REPRESENTATIVE AND TYPICAL DETAILS TD ASSIST THE CONTRACTOR, THE DRA',/INGS DD NOT ILLUSTRATE EVERY CONDITION, ALL ATTACHMENTS, CONNECTIONS, FASTENING, ETC. SHALL BE PROPERLY SECURED IN CONFORMANCE OF THE BEST PRACTICE, AND THE CONTRACTOR SHALL BE RESPONSIBLE FDR PROVIDING AND INSTALLING THEM. THE DISCHARGE OF POLLUTANTS TD ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID ',/ ASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION ',/ASTE MATERIALS, DR ',/ASTE',/ATER GENERATED ON CONSTRUCTION SITES DR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED DR DISCHARGED INTO THE STREET, GUTTER DR STORM DRAIN SYSTEM. UNLESS SPECIFICALLY DETAILED ON THESE DRA',/INGS, CONTRACTOR SHALL FURNISH AND INSTALL ADEQUATE SHORING, BRACING, ECT, REQUIRED TO SAFELY EXECUTE ALL ',/ORK AND SHALL BE FULLY RESPONSIBLE FDR SAME. DETAILS AND CONDITIONS SPECIFICALLY SHO',/N SHALL BE CONSTRUCTED IN ACCORDANCE ',/ITH DETAILS SHO',/N FDR SIMILAR CONDITIONS AND MATERIAL. ALL EXCAVATIONS, PREPARATIONS FOR SLAB ON GRADE, DEPTH OF FOOTINGS, BACK FILL, ECT, SHALL BE PERFORMED IN ACCORDANCE ',/ITH THE 2016 CRC. IN THE AREA OF CONSTRUCTION, REMOVE ALL EXISTING FILL, NEAR SURFACE SOILS, VEGETATION, DEBRIS AND DISTURBED SOILS. AREAS OF OVER CUT MAY □NL Y BE BROUGHT TD GRADE ',/ITH CLEAN AND MOISTENED SAND, ND GRADING REQUIRED ON THIS PROJECT CONCRETE ',/ASH□UT, CONTRACTOR SHALL ESTABLISH AND USE AN ADEQUATELY SIZED CONCRETE ',/ASHOUT AREA TD CONTAIN ',/ASHDUT · ',/ASTES ON SITE, IT IS ILLEGAL TO ',/ASH CONCRETE, SLURRY, MORTAR, STUCCO, PLASTER AND THE LIKE INTO THE STORM',/ATER CONVEYANCE SYSTEM DR ANY RECEIVING ',/ATER, CONTRACTOR SHALL POST A SIGN DESIGNATING THE ',/ A SHOUT LOCA TIDN. CONSTRUCTION SITE ACCESS, A STABILIZED CONSTRUCTION SITE ACCESS SHALL BE PROVIDED FOR VEHICLES EGRESS AND INGRESS TD PREVENT TRACKING DIRT DFFSITE, THIS SHALL INCLUDE USING MATERIAL SUCH AS GRAVEL AND/OR CORRUGATED STEEL PANELS/PLATES. CONSTRUCTION VEHICLES A SPECIFIC AREA A',/AY FROM GUTTERS AND STDRMDRAIN SHALL BE DESIGNATED FDR CONSTRUCTION VEHICLES · PARKING, VEHICLE REFUELING, AND ROUTINE EQUIPMENT MAINTENANCE. ALL MAJOR REPAIRS SHALL BE MADE OFF -SITE, EROSION CONTROL EROSION CONTROL MUST BE PROVIDED FDR ALL EROSIVE SURFACES, SLOPED SURFACES ESPECIALLY SHALL BE PROTECTED AGAINST EROSION BY INSTALLING EROSION RESISTANT SURFACES SUCH AS EROSION CONTROL MATS, ADEQUATE GROUND COVER VEGETATION, AND BONDED FIBER MATRIX. PLAN REQUIREMENTS THIS PROJECT SHALL C□MPL Y 'vJITH THE 2016 CALIFORNIA RESIDENTIAL CODE (CRC) AND/DR CALIFORNIA BUILDING CODE (CBC) AS APPLICABLE, 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), 2019 CALIFORNIA ELECTRICAL CODE <CEC), 2019 CALIFORNIA PLUMBING CODE <CPC), 2019 CALIFORNIA FIRE CODE (CFC), 2019 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS <CBEES). AMENDMENTS TD THE CITY OF VISTA ADMINISTRATIVE CODE FDR BUILDING REGULATI□NS. PROJECT DAT Ai OCCUPANCY: 'R3' TYPE OF C□NSTRUCTI□N, VB FIRE SPRINKLERS, NO USE, (N MAIN FLOOR ATTACHED GARAGE (N UPPER FLOOR ATTACHED ADU CODE COMPLIANCE• 2019 CALIFORNIA BUILDING CODE. NUMBER OF STORIES• T'w□ SCOPE OF w'□RK• CREATE A NE',/: 3-CAR ATTACHED GARAGE AND STORAGE AT REAR OF THE PROPERTY, A NE',/ UPPER FLOOR ADU 908 SQFT, (ABOVE GARAGE) .. PROVIDE NEw' 100 AMP SUB-PANEL. LDT COVERAGE: <E) SFD, OTHER STRUCTURES, (N) GARAGE AND STORAGE FOOTPRINT LDT AREA I LDT COVERAGE 4094 SQFT 32,670 SQFT 12.531/. 1 DD NOT SCALE DRA',/INGS. USE FIGURED DIMENSION □NL Y; REPORT ALL DISCREPANCIES TD DESKIN BUILDING DESIGN IMMEDIATELY. PLAN N□TES1 PLOT PLAN AND SETBACK INF□RMA TION IS BELIEVED TD BE RELIABLE, H□'vJEVER ND LIABILITY SHALL BE ASSUMED BY DESKIN BUILDING DESIGN. CONTRACTOR AND □'vJNER SHALL VERIFY ALL BUILDING SETBACKS PRI□R TD PLACEMENT OF ANY NEw' STRUCTURES, AND SHALL FULLY COMPLY 'vJITH THE ZONING DEPARTMENT OF CITY /COUNTY HAVING JURISDICTION. HERS VERIFICATI □N REQUIRED THE F□LL□'vJING IS A SUMMERY OF THE FEATURES THAT Ml.ill BE FIELD VERIFIED BY A CERTIFIED HERS RATER AS A CONDITION FDR MEETING THE MODELED ENERGY PERFORMANCE FDR THIS COMPUTER ANALYSIS. BUILDING LEVEL VERIFICA TI□NS1 • KITCHEN RANGE HODD COOLING SYSTEM VERIFICATI□NS, • VERIFIED REFRIGERANT CHARGE HEATING SYSTEM VERIFICA TI□NS• • --N□NE-- HVAC D!STRIBUTI□N SYSTEM VERIFICA TI□NS, • --NONE-- DOMESTIC HOT 'vJATER SYSTEM VERIFICATIONS, • --NONE-- REQUIRED SPECIAL FEATURES• THE FDLL□'vJING ARE FEATURES THAT Ml.ill BE INSTALLED AS A CONDITION FDR MEETING THE MODELED ENERGY PERFORMANCE FDR THIS COMPUTER ANALYSIS. • ND SPECIAL FEATURES REQUIRED STORM 'w'ATER QUALITY N□TES CONSTRUCTIDN BMP'S I w' _JI ~I 1--f u <C I- (,I) 1--f > <C z w :::) ~ _, - THIS PR□JECT SHALL CDMPL Y 'w'ITH ALL REQUIREMENTS IJF THE STATE PERMIT1 CALIFORNIA REGIONAi \JAIER QUALITY CnNTR□I BOARD SAN nIFGQ REGT□N, ORDER NO ?001 01 NPJlFS NO CAS010875 CHTTP1/ /W'w' Sw'RCP.CA.G□V /R'JQCB9/PR□GRAMS/SD_STCRMVATER,HTMUJ AND THE CITY □F SAN DIEGO LAND DEYELOPEMENT CODE CHTTP1/ /CLERCKD□C.SANNET .G□V /RIGHTSITE/GETCDNTENT /LDCAL.PDF7DM'w' _aBJECTID=090014518008CC43), NOTES 1-6 BEL□'w' REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION BMP'S, 1. SUFFICIENT BMP'S MUST BE INSTALLED T□ PREVENT SILT, MUD, □R OTHER CONSTRUCTillN DEBRIS FRDH BEING TRACKED INT□ ADJACENT STREET<S) □R STORM IJATER CONVEYANCE. SYSTEMS DUE TD CDNSTRUCTI□N VEHICLES □R ANY □THER SUCH C□NSTRUCTI□N ACTIVITY. THE c□NTRACT□R SHALL BE RESP□NSIELE F□R THE CLEANING □F ANY SUCH DEBRIS THAT MAY J3E IN THE STREET AT THE END □f' EACH 'w□RK DAY DR AFTER A STORM EVENT THAT CAUSES A BREECH JN THE INSTALLED CDNSTRUCTJ□N BMP'S. 2, ALL STOCK PILES OF UNCOMPACTED S□IL AND/DR BUll_DING MATERIALS THAT ARE INTENDED T□ BE LEFT UNPROTECTED f'DR A PERIOD GREATER THAN SEVEN CALENDAR DAYS ARE TD BE PROVIDED 'w'ITH EROSIDN AND SEDIMENT CONTROLS. SUCH SOIL MUST BE PROTECTED EACH DAY 'wHEN THE PROBABILITY OF RAIN IS 40"/. OR GREATER, 3, A CCNCRETE 'wASHOUT SHALL BE PROVIDED ON ALL PROJECTS IJHICH PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPREIVEHENTS THAT ARE TD BE POURED IN PLACE DN THE SITE. 4, ALL EROSION/SEDIMENT CONTROL DEVICES SHALL BE MAINTAJNED IN lJ□RKING ORDER AT ALL TJHES. 5, ALL SLOPES THAT ARE CREATED DR DISTURBED BY C□NSTRUCTJ□N ACTIVITY MUST BE PROTECTED AGAINST ER□Sl□N AND SEDIMENT TRANSPORT AT ALL TIMES. 6, THE STORAGE □F ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRDNMENT, .. 'q" C> \() (\J (\J (N) MAIN FLR GARAGE-~ WITH UPPER FLR ADU 105.69' (N) STORAGE- (E) SHED---- -+----57' -10' ---+---,!<-!- I ~(E) BARN (E) DRIVE----.. (E) STUDIO- (E) GUEST RM~ -I--31'-10' --l.lL • 0 I ' (J's -st- 10' -0' --.----+-_ 30'.~-8' ,---,,fa~ . . . • .. 5'-0' .. C> C> \() If) (\J 6.00' ., ____ .....:,~------1 109.93' L ---------- LAGUNA DRIVE II SITE PLAN DRAINAGE, • 0 I • C) I ' 0 0 (Y) (\j --------i~ -i---t. CITY OF CARLSBAD Administrative Permit · "' Date i i 2-l / zoUL-Exibit Nn A-K SCALE 1 '= 20' THE FINISH GRADE AND IMPERVIOUS SURFACES SHALL DRAIN A',/AY FROM THE FOUNDATION ',/ALLS AT A MINIMUM SLOPE OF 2% DR SHALL FALL 6-INCHES ',/!THIN THE FIRST 10-FEET ',/HERE POSSIBLE, (SECTION R40D. NE',/ AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS DR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET DR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST IN COLOR TD BACKGROUND. NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH AND ',/ITH A MINIMUM STROKE ',/IDTH OF 1/2 INCH. (CFC SEC, 505,D, THE DISCHARGE OF POLLUTANTS TO ANY STORM ',/ATER DRAINAGE SYSTEM IS PROHIBITED. ND SOIL, ',/ASTE, PETROLEUM BY PRODUCTS, SOLID PARTICULATE, CONSTRUCTION ',/ASTE MATERIAL DR ',/ASTE',/ATER GENERATED ON CONSTRUCTION SITE DR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED, DR DISCHARGED INT□ THE STREET, GUTTER DR STORM DRAIN SYSTEM. VICINITY MAP ~4 r-(/) ;.._'I: z !:? □ _:,. (/) c~ O! ~ w t... 1!J t... LAGUNA DRIVE w "' -, n ~ ]> r;R□JECT SITE ;;o ,JI,>, II r \ (/) ">".,>, "" ]> <' t:I ~ ~ tl \ OWNER1 "'' --.,.,·; ,,.., .. ' MAYUR PAVAGADHI 624 LAGUNA DRIVE I' 'I' " ' '"'?' v0 \ l.i" '-C,J_ I CARLSBi\D, CA. 92008 :-: -::; .. ·: ,_;; .. _,' ' C (760) 500-0300 ' :"< :''-;; :-...: :~.:; :.. .. · .. '·=; :=:. ' CONTACT, MAYUR PAVAGADHI 624 LAGUNA DRIVE CARLSBAD, CA, 92008 (760) 500-0300 LEGAL JJESCRIPTION1 624 LAGUi~A DRIVE CARLSBAD, CA, 92008 ,- SECT: 12-12-5\./* TRACT: lllE0,75 AC: MIL IN ASSESSORS PARCEL NUMBER 155-223-18 SUMMERY TABLE <PROPOSED)1 . (E) SFD: 1842 SQFT (E) GUEST hOUSE 313 SQFT CE) STUDIO 212 SQFT CE) BARN 610 SQFT CN) ATTACHED GARAGE 1080 SQFT (N) ATTACHED STORAGE 36,66 SQFT CN) ATTACHED UPPER FLR ADU 908,00 SQFT TOTAL LIVING : 2367+908 -3275 SQFT SHEET INDEX p SHEET DESCRIPTION 1 SITE PLAN -REVISION G GREE~~ BUILDING CODE REQUIREMENTS N NOTES T24 TITLE 24 ENERGY CALCS 3 GARAGE FOUNDATION PLAN 4 GARAGE MAIN FLOOR PLAN -REVISION 5 UPPER FLOOR ADU PLAN -REVISION 6 MAIN FRAMING PLAN -REVISION 7 UPPER ADU FRAMING PLAN -REVISION 8 SECTIONS 9 SECTIONS -REVISION 10 ELEVATIONS 11 ROOF PLAN 12 GARAGE MAIN ELECTRICAL PLAN 13 UPPER ADU ELECTRICAL PLAN -REVISION SDl DETAIL SHEET SD2 DETAIL SHEET SD3 DETAIL SHEET THESE DRA ',/I~JGS SHO',/ □NL Y REPRESENTATIVE AND TYPICAL DETAILS TD ASSIST THE CONTRACTOR. THE DRA ',/JNGS DD NOT ILLUSTRATE EVERY CONDITION, ALL ATTACHMENTS, CONNECTIONS, FASTENING, ETC, SHALL BE PROPERLY SECURED IN CONFORMANCE OF THE BEST PRACTICE, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INST ALLING THEM. DRAw'N BY• MATTHEw' DESKIN REVISIONS (!) z -C ...J -::, al zz -(!) ~-U) U) ww cc ::, C <C I w (!) ~ <C (!) I - LJ.J > -a::: 0 0 Q LO 0 ..,... 0 s~~ ZN' om~ I-. -..:I" I-(_)<( --0 0 (_) <( fe NI-._. LO Cl) . r---I ..,... > CL co ...- I C") N 0~ 0 LO C") LO 0 ...- I 0 0 LO DRAWN CHECKED DATE SCALE SHEET 1 GREEN BUILDING CODE REQUIREMENTS STORM 'w'ATER DRAINAGE/RETENTION DURING CONSTRUCTION, PROJECTS 'w'HICH DISTURB LESS THAN □NE ACRE OF SOIL SHALL MANAGE STORM 'w'ATER DRAINAGE DURING CONSTRUCTION BY ONE OF THE FOLLD'w'ING, o.) RETENTION BASINS b) 'w'HERE STORM 'w' ATER IS CONVEYED TD A PUBLIC DRAINAGE SYSTEM, 'w'ATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, 'w'ATTLE OR OTHER APPROVED METHOD, (CGC 4.106.2,), GRADING AND PAVING, SITE GRADING OR DRAINAGE SYSTEM 'w'ILL MANAGE ALL SURFACE 'w'ATER FL□'w'S TD KEEP 'w'ATER FROM ENTERING BUILDINGS <S'w' ALES, 'w' ATER COLLECTION, FRENCH DRAINS, ETC,), (CGC 4.106,3,), EXCEPTION, ADDITIONS NOT ALTERING THE DRAINAGE PATH. LANDSCAPE IRRIGATION 'w'ATER. PROJECTS 'w'ITH LANDSCAPE IRRIGATION 'w'ATER USE SHALL HAVE 'w'EATHER DR SOIL BASE CONTROLLERS, (CGC 4.304,1.), RECYCLING, A MINIMUM OF 651/. OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION 'w'ASTE IS TD BE RECYCLED (CGC 4.408.1.) RECYCLING, THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION 'w'ASTE MANAGEMENT PLAN TD THE JURISDICTIONAL AGENCY THAT REGULATES 'w'ASTE MANAGEMENT, PER, (CGC 4.408,2.), PROVIDE R-6 INSULATION FOR DUCT 'w'□RK IN UNCONDITIONED SPACES, PROVIDE A MINIMUM 100 CFM KITCHEN HODD EXHAUST TD THE EXTERIOR 'w'ITH METAL DUCT'w'□RK, A CEILING OR 'w' ALL EXHAUST MAY BE USED THAT PROVIDES 5 AIR CHANGES PER HOUR. HEATING AND AIR-CONDITIONING SYSTEM DESIGN, HEATING AND AIR-CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED, AND HAVE THEIR EQUIPMENT SELECTED USING THE F□LL □'w'ING METHODS (CGC 4,507.2)1 o., THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TD ANSI/ACCA 2 MANUAL J ASHRAE HANDBOOKS, DR OTHER EQUIVALENT DESIGN S□FT'w'ARE DR METHODS, b, DUCT SYSTEMS ARE SIZED ACCORDING TD ANSI/ACCA 1 MANUAL D 2009, ASHRAE HANDBOOKS, DR OTHER EQUIVALENT DESIGN S□FT'w'ARE DR METHODS, c. SELECT HEATING AND CODLING EQUIPMENT ACCORDING TD ACCA 36-S MANUAL S DR OTHER EQUIVALENT DESIGN SDFT'w'ARE DR METHODS. CONSTRUCTION 'w'ASTE REDUCTION, DISPOSAL, AND RECYCLING, REDUCE AND/DR SALVAGE FDR REUSE A MINIMUM OF 65 PERCENT OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS, (CGC 4.408.D EXCEPTION, EXCAVATED SOIL AND LAND-CLEARING DEBRIS EXCEPTION, ALTERNATE 'w'ASTE REDUCTION METHODS DEVELOPED BY 'w'□RKING 'w'ITH LOCAL AGENCIES IF DIVERSION DR RECYCLE FACILITIES CAPABLE OF COMPLIANCE 'w'ITH THIS ITEM DD NOT EXIST DR ARE NOT LOCATED REASONABLY CLOSE TD J□BSITE, OPERATION AND MAINTENANCE MANUAL, PRIOR TD FINAL INSPECTION, A MANUAL, COMPACT DISC, 'w'EB-BASED REFERENCE, DR OTHER ACCEPTABLE MEDIA 'w'HICH INCLUDES ALL OF THE F □LLD'w'ING SHALL BE PLACED IN THE BUILDING. (CGC 4.410,D• o., DIRECTIONS TD □'w'NER DR OCCUPANT THAT MANUAL SHALL REMAIN 'w'ITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE, b. EQUIPMENT AND APPLIANCES, INCLUDING 'w'ATER-SAVING DEVICES AND SYSTEMS, HVAC SYSTEM, PH□T□V□L TAIC SYSTEMS, 'w'ATER-HEATING SYSTEMS AND OTHER MAJOR APPLIANCES AND EQUIPMENT, I. ROOF AND YARD DRAINAGE, INCLUDING GUTTERS AND D□'w'NSP□UTS, II, OPERATIONS AND MAINTENANCE INSTRUCTIONS FDR THE F□LL□'w'ING1 Iii, SPACE CONDITIONING SYSTEMS, INCLUDING CONDENSERS AND AIR FILTERS, Iv. LANDSCAPE IRRIGATION SYSTEMS, v, 'w'ATER REUSE SYSTEMS. c. INFORMATION FROM LOCAL UTILITY, 'w'ATER, AND 'w'ASTE RECOVERY PROVIDERS ON METHODS TD FURTHER REDUCE RESOURCE CONSUMPTION, INCLUDING RECYCLE PROGRAMS AND LOCATIONS, d. PUBLIC TRANSPORTATION AND/DR CARPOOL OPTIONS AVAILABLE IN THE AREA, e, EDUCATIONAL MATERIAL ON THE POSITIVE IMPACTS OF AN INTERIOR RELATIVE HUMIDITY BET'w'EEN 30-60 PERCENT AND 'w'HAT METHODS AN OCCUPANT MAY USE TD MAINTAIN THE RELATIVE HUMIDITY LEVEL IN THAT RANGE. f, INFORMATION ABOUT 'w'ATER-C□NSERVING LANDSCAPE AND IRRIGATION DESIGN AND CONTROLLERS 'w'HICH CONSERVE 'w'ATER. g. INSTRUCTIONS FDR MAINTAINING GUTTERS AND D□'w'NSP□UTS AND THE IMPORTANCE OF DIVERTING 'w'ATER AT LEAST 5 FEET A'w'AY FROM FOUNDATION, h. INFORMATION ON REQUIRED ROUTINE MAINTENANCE MEASURES, INCLUDING, BUT NOT LIMITED TD CAULKING, PAINTING, GRADING AROUND THE BUILDING, ETC, i. INFORMATION ABOUT STATE SOLAR ENERGY AND INCENTIVE PROGRAMS AVAILABLE. J. A COPY OF ALL SPECIAL INSPECTION VERIFICATIONS REQUIRED BY THE ENFORCING AGENCY, ALL 'w'ATER CLOSETS SHALL HAVE AN EFFECTIVE FLUSH VOLUME OF NOT MORE THAN 1.28 GALLONS PER FLUSH. TANK TYPE 'w'ATER CLOSET SHALL BE CERTIFIED TD THE PERFORMANCE CRITERIA OF THE U.S. EPA 'w'ATER SENSE SPECIFICATION FDR TANK. TYPE TOILETS. <CGC 403,1.D, URINALS SHALL HAVE AN EFFECTIVE FLUSH VOLUME NOT TD EXCEED 0.5 GALLONS PER FLUSH, (CGC 403,1.2), SINGLE SH□'w'ER HEADS SHALL HAVE A MAXIMUM FLD'w' RATE OF NOT MORE THAN 2,0 GALLONS PER MINUTE AT 80 PSI. MULTIPLE SH□'w'ER HEADS 'w'HEN SERVED BY A SINGLE VAL VE SHALL HAVE A COMBINED FL□'w' RATED NOT TD EXCEED 2.0 GALLONS PER MINUTE, (CGC 403,1.3.D. RESIDENTIAL LAVATORY FAUCETS SHALL HAVE A MAXIMUM RATE 1.5 GALLONS PER MINUTE AT 60 PSI AND A MINIMUM FL□'w' RATE OF NOT LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. <CGC 403,1.4,2). KITCHEN FAUCETS SHALL HAVE A MAXIMUM FL□'w' RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS TEMP□RARIL Y INCREASE THE FL□'w' RATE TD A MAXIMUM OF 2.2 GALLONS PER MINUTE AT 60 PSI ALLD'w'ED BUT MUST DEFAULT BACK TD THE 1.8 GALLONS PER MINUTE. (CGC 403.1.4.4). A PLUMBING FIXTURE CERTIFICATION MUST BE COMPLETED AND SIGNED BY EITHER A LICENSED GENERAL CONTRACTOR, DR A PLUMBING CONTRACTOR DR THE BUILDING □'w'NER CERTIFYING THE FL□'w' RATE OF THE FIXTURES INSTALLED. JOINTS AND OPENING, ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, DR OTHER OPENINGS IN SOLE/BOTTOM PLATES OF EXTERIOR 'w'ALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS 'w'ITH CEMENT MORTAR, CONCRETE MASONRY DR OTHER METHOD ACCEPTED BY AGENCY, (CGC 4.406,D, DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION, (CGC 4,504,D, ADHESIVE, SEALANTS AND CAULKS SHALL BE COMPLIANT 'w'ITH voe AND OTHER TOXIC COMPOUND LIMITS, (CGC 4,504,2,D. ADHESIVE, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL C □MPL Y 'w'ITH LOCAL OR REGI □NP,L AIR POLLUTION CONTROL DR AIR QUALITY MANAGEMENT DISTRICT RULES 'w'HERE APPLICABLE, DR SCAQMD RULE 1168 voe LIMITS, AS SH □'w'N IN TABLES 4,504.1 AND 4.504,2 OF CALGREEN , (CGC 4.504,2.4). AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT DR CAULKING COMPOUNDS <IN UNITS OF PRODUCT, LESS PACKAGING, 'w'HICH DD NOT 'w'EIGH MORE THAN □NE POUND AND DD NOT CONSIST OF MORE THAN 16 FLUID DUNCES) SHALL C□MPL y 'w'ITH STATE'w'IDE voe STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING 'w'ITH SECTION 94507, (CGC 4.504,2.4), ARCHITECTURAL PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT 'w'ITH voe LIMITS SET IN SECTION 4,504,2,2 AND TABLE 4,504.3, AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT 'w'ITH PRODUCT 'w'EIGHTED MIR LIMITS FDR voe AND OTHER TOXIC COMPOUNDS AS SPECIFIED IN (CGC 4,504,2,3). INTERMITTENTLY OPERATED <KITCHEN, BATH, ETC.) LOCAL EXHAUST FANS SHALL BE RATED AT 3,0 SONES DR LESS, THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TD ACCA MANUAL J, ASHRAE HANDBOOKS DR OTHER EQUIVALENT DESIGN S□FT'w'ARE DR METHODS. OPERATION AND MAINTENANCE MANUAL, THE BUILDER SHALL PROVIDE AN OPERATION MANUAL <CONTAINING INFORMATION FDR MAINTAINING APPLIANCES, ETC.) FDR THE □'w'NER AT THE TIME OF FINAL INSPECTION, (CGC 4.410,1.), POLLUTANT CONTROL, DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TD BE SEALED, AND MECHANICAL EQUIPMENT IS TD BE COVERED, (CGC 4,504,1.), POLLUTANT CONTROL, V□C'S MUST C□MPL Y 'w'ITH THE LIMITATIONS LISTED IN SECTION 4,504,3 AND TABLES 4,504.1, 4.504,2, 4,504.3 AND 4,504.5 FDR ADHESIVES, PAINT AND COATINGS, CARPET AND COMPOSITION 'w'□□D PRODUCTS, (CGC 4,504,2,), INTERIOR MOISTURE CONTROL: CONCRETE SLABS SHALL BE PROVIDED 'w'ITH A CAPILLARY BREAK (CGC 4,505.2.1.), INTERIOR MOISTURE CONTROL, THE MOISTURE CONTENT OF 'w'□□D SHALL NOT EXCEED 191/. BEFORE IT IS ENCLOSED IN CONSTRUCTION, THE MOISTURE CONTENT NEEDS TD BE CERTIFIED BY □NE OF 3 METHODS SPECIFIED IN SECTION 4,505.3, BUILDING MATERIALS 'w'ITH VISIBLE SIGNS OF 'w'ATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION, THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY □NE OF THE METHODS LISTED IN CGC 4.505,3, INDOOR AIR QUALITY, BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TD THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT, <CGC 4.506,1.), OFFICIAL 'w'RITTEN VERIFICATION, PRIOR TD FINAL INSPECTION THE LICENSED C □NTRACTQR, ARCHITECT, DR ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST PROVIDE TD THE BUILDING DEPARTMENT OFFICIAL 'w'RITTEN VERIFICATION THAT ALL APPLICABLE PROVISIONS FROM THE GREEN BUILDING STANDARDS CODE HAVE BEEN IMPLEMENTED AS PART OF THE CONSTRUCTION. <CGC 410,D. CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT 'w'ITH voe LIMITS, (CGC 4,504.3) A LETTER FROM THE GENERAL CONTRACTOR, SUBCONTRACTOR AND DR THE BUILDING □'w'NER CERTIFYING THAT MATERIALS USED COMPLIES 'w'ITH THE CALIFORNIA GREEN CODE. 80 PERCENT OF THE FLOOR AREA RECEIVING RESILIENT FLOORING SHALL C□MPL Y 'w'ITH □NE DR MORE OF THE F□LL□'w'ING: 0., voe EMISSION LIMITS DEFINED IN THE COLLABORATIVE FDR HIGH PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCTS DAT ABASE, b, PRODUCT COMPLIANCE 'w'ITH CHIPS CRITERIA CERTIFIED UNDER THE GREENGUARD CHILDREN AND SCHOOL PROGRAM, c, CERTIFICATION UNDER THE FLOOR COVERING INSTITUTE (RFCD FLOOR SCORE PROGRAM. d, MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEAL TH, 'STANDARD METHOD FDR THE TESTIMG AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS' FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, VERSION 1.1 FEBRUARY 2010, HARD'w'□□D PL Y'w'□□D, PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD, COMPOSITE 'w'□□D PRODUCT USED ON THE INTERIOR DR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FDR FORMALDEHYDE AS SPECIFIED IN ARB's AIR TOXIC CONTROL MEASURE FDR COMPOSITE 'w'□□D AS SPECIFIED IN SECTION 4,504.5 AND TABLE 4,504.5, A CERTIFICATION COMPLETED AND SIGNED BY GENERAL CONTRACTOR, SUBCONTRACTOR, DR THE BUILDING □'w'NER CERTIFYING THAT THE RESILIENT FLOORING, COMPOSITE 'w'□□D PRODUCT, PL Y'w'□□D PARTICLE BOARD C□MPL y 'w'ITH THE voe LIMITS AND FORMALDEHYDE LIMITS SPECIFIED IN THE NOTES ABOVE AND THE CALIFORNIA GREEN CODE. VAPOR RETARDER AND CAPILLARY BREAK IS INSTALLED AT SLAB ON GRADE FOUNDATIONS, SH□'w' □NE OF THE F□LLD'w'ING METHODS ON PLAN• (CGC 4.504,2,D, o., 4-INCH BASE OF 1/2-INCH DR LARGER CLEAN AGGREGATE SHALL BE PROVIDED 'w'ITH A VAPOR BARRIER IN DIRECT CONTACT 'w'ITH CONCRETE AND A CONCRETE MIX DESIGN 'w'HICH ADDRESS BLEEDING, SHRINKAGE, AND CURING SHALL BE USED, b, A SLAB DESIGN SPECIFIED BY A LICENSED DESIGN PROFESSIONAL. EACH BATHROOM SHALL BE MECHANICALLY VENTILATED, FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TD TERMINATE OUTSIDE THE BUILDING, UNLESS FUNCTIONING AS A COMPONENT OF A 'w'H□LE-H□USE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL \.iHICH SHALL BE CAPABLE OF ADJUSTMENT BET',/EEN A RELATIVE HUMIDITY RANGE OF MINIMUM 501/. TD A MAXIMUM OF 801/.. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TD THE EXHA:JST FAN AND IS NOT REQUIRED TO BE INTEGRAL. (CGC 4.506,D, THE MOISTURE CONTENT OF BUILDING MATERIAL USED IN 'w'ALLS AND FLOOR FRAMING IS CHECKED BEFORE ENCLOSURE, MOISTURE CONTENT SHALL BE VERIFIED EITHER A PROBE TYPE CONTACT TYPE MOISTURE METER. <CGC 4,504), THE DISCHARGE OF POLLUTANTS TD ANY STORM 'w'ATER DRAINAGE SYSTEM IS PROHIBITED, ND SOIL 'w'ASTE, PETROLEUM BY PRODUCTS, SOLID PARTICULATE, CONSTRUCTION 'w'ASTE MATERIAL OR 'w'ASTE'w'ATER GENERATED ON CONSTRUCTION SITE DR tY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED, DR DISCHARGED INT □ THE STREET, GUTTER DR STORM DRAIN SYSTEM. CONSTRUCTION 'w'ASTE MANAGEMENT PLAN: A CONSTRUCTION 'w'ASTE MANAGEMENT PLAN SHALL BE PREPARED AND AVAILABLE ON SITE DURING CONSTRUCTION, DOCUMENTATION DEMONSTRATING COMPLIANCE 'w'ITH THE PLAN SHALL BE ACCESSIBLE DURING CONSTRUCTION FDR THE ENFORCING AGENCY, (CGC 4.408,2) THE PLAN• o., IDENTIFY THE CONSTRUCTION AND DEMOLITION 'w'ASTE MATERIALS TD BE DIVERTED FROM DISPOSAL BY RECYCLING, REUSE ON THE PROJECT DR SALVAGE FDR FUTURE USE DR SALE. b, SPECIFY IF CONSTRUCTION OR DEMOLITION 'w'ASTE MATERIALS 'w'ILL BE SORTED ON-SITE (SOURCE SEPARATED) DR BULK MIXED (SINGLE STREAM), c. IDENTIFY DIVERSION FACILITIES 'w'HERE THE CONSTRUCTION AND DEMOLITION 'w'ASTE 'w'ILL BE TAKEN, d, IDENTIFY THE CONSTRUCTION METHODS EMPLOYED TD REDUCE THE AMOUNT OF CONSTRUCTION AND DEMOLITION 'w'ASTE GENERATED, e, SPECIFY THAT THE AMOUNT OF CONSTRUCTION AND DEMOLITION 'w'ASTE MATERIALS SHALL BE CALCULATED BY 'w'EIGHT DR VOLUME NOT BY BOTH, MOISTURE CONTENT OF BUILDING MATERIALS, BUILDING MATERIALS 'w'ITH VISIBLE SIGNS OF 'w' ATER DAMAGE SHALL NOT BE INSTALLED. 'w'ALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED 'w'HEN THE FRAMING MEMBERS EXCEED 19 PERCENT MOISTURE CONTENT, MOISTURE CONTENT SHALL BE VERIFIED IN COMPLIANCE 'w'ITH THE F □LL□'w'ING (CGC 4,505.3): o., MOISTURE CONTENT SHALL BE DETERMINED 'w'ITH EITHER A PROBE-TYPE OR CONTACT-TYPE MOISTURE METER, b, MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET TD 4 FEET FROM GRADE STAMPED END OF EACH PIECE TD BE VERIFIED. c. AT LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED ON 'w'ALL AND FLOOR FRAMING 'w'ITH DOCUMENTATION ACCEPTABLE TD THE ENFORCING AGENCY PROVIDED AT THE TIME OF APPROVAL TD ENCLOSE THE 'w'ALL AND FLOOR FRAMING. d, INSULATION PRODUCTS 'w'HICH ARE VISIBLY 'w'ET DR HAVE HIGH MOISTURE CONTENT SHALL BE REPLACED DR ALL□'w'ED TD DRY PRIOR TD ENCLOSURE IN 'w'ALL AND FLOOR CAVITIES, 'w'ET-APPLIED INSULATION PRODUCTS SHALL F□LL□'w' THE MANUFACTURERS DRYING RECOMMENDATIONS PRIOR TD ENCLOSURE. REVISIONS w (!) > -z a:: 0 -C 0 ..J 0 LO -0 ....-0 ::, s co LO 0 ....-al z N I om~ zz t-. "st -C) t-<(. 0 00 ~ -(.) -(0 en en <( r-- WW N t-,_ LO Cl) . cc r---I ....-> a_ DRAWN CHECKED DATE SCALE SHEET G A. General Applicable codes. All projects shall comply with ths 2019 Galifamia Building Code (CBC) and/or California Residential Code (CRC), 2019 California Green Building Standards Code (CalGreen), 2019 Galifomia Electrical Code (CEC), 2019 California Mechanical Gode (CMG), 2019 Ga/ifomia Plumbing Code (CPC), 2019 Caliliomia Fire Code (CFC), 2019 GaNfamia Building Energy E/fic/en,;y Standards (CBEES), and all County of Sail Diego amendments. A. Electrical, Plumbing, and Mechanical 1. Exrerior lighting. All projects shall comply with the County of San Diego lighting ordinance. 2. GFCI outlets. Ground Fault Circuit lnterriupter (GFC!} outlets are required in bathrooms, at kitchen countertops, at laundry and wet bar sinks, in garages, in crawlspaces, in unfinished basements, and outdoors. (CEC 21 G.8) 3. AFC! outlets. Bectrical circuits in becifooms, living rooms, dlnfng rooms; dens, closets, hallways,. or similar rooms must be protected by Arc Fault Circuit Interrupters (AFC!}. (CEC 210.12) 4. Ltiminaire.requiraments. Installed lum!nalres shall meet the efficacy and fixture requirements of CBEES 150.0(k). 5. Smoke detectors in building remodels. Smoke detectors are required in each existlng s!eeping room, outside each separate sleeping area in the immediate vicinity cf sleeping moms, and on each story of a dwe!Hng including basements. Battery~operated detectors are accept.able in existITTg areas with no construction taking place ard in alterations not resulting in removal of interior wall or cemng finishes and without access via an attic, crawl space, or basament. (CRC R314.3) 6. Carbon monoxide detectors in building remodels. Carbon monoxide detectors are required outside each separate sleeplng area in the immediate vicinity of sleeping rooms and on each story of a dwe!l[ng including basements. Battery~operated detectors are acceptable ITT existing areas with no construction taking place and in alterations not resulting in removal of interlorwaU or ceiling finishes and without access via an attic, cra'M space, or basement (CRC R315,3) 7. Water heater seismic strapping. Mlnimum two 3/4-inch-by-24-gauge straps required around water heaters, with 114-inch-by-3-inch lag bolts attached directly to framing. Straps shall be at points within upper third and lower third of water heater vertica[ dimension, Lower connection shal! occur minimum 4 inches above controls. (CPC 507 2} 8. Gas appliances in garages. Water heaters and heating/cooling equipment capable of igniting flammable vapors shall be placed on minimum 18-inch-high platform unless listing report number provided showing ignition-resistant appltance. {CPC 507.13 and CMC 305.1) 9. impact protection of appliances. Water heaters and heatingJcooling equipment subject to vehicular impact sha!f be protected by-bollards or an equivalent measure. (CPC 507.13.1 and CMC 305.11) 10. Water cloSet clearance. Minimum 30-inch-wide by 24-lnch-deep clearance r~uired at front of water closets. (CPC 402_5) 11. Shower size. Shower compartments shall have. minimum area of 1024 square inches and be a.ble to encompass a 30-inch-d!ameterclrcle. Shower doors shall have a minimum 22~inch unobstructed width {CPC 408.5 and CPC 408.6} 12. Fireplace appliances. Flrepfaces with gas appliances are required to have the flue damper permanently fixed fn the open position and fireplaces with LPG appliances are to have no 'pit' or 'sump' configurations, (CMG 303.7.1) 13. Chimney clearance. Minimum 2-foot chimney clearance required above bui!ding·withln 10-foot horizontally of chimney. The chimney shal! extend minimum 3 feet above hi'ghest point where chimney passes through roof. (CRC R1003.9) C. Mechanical Ventilation and Indoor Air Quality (ASHRA.E 62.2~2010) 1. Transfer air. Ventilatton air shall be provided directly .from the outdoors and not as transfer afr from adjacent dweJling units or other spaces, such as garages, unconditioned crawlspaces, or unconditioned attics. (CBEES 150.0(o)) 2; Instructions and labeling. Ventilation system controls shall be labeled and. the home owner shall be provided with instructions on how to operate the system. (CBEES 150.0(o)) 3. Combustion and-solid..fuel burning appliances. Combustion appliances shall' be properly vented and air systems sha!I be designed to prevent back drafting, (CBEES 150.0[o)) 4. Garages. The wa!I and openings between occuptab[e spaces and the garage sha!I be sealed. HV AC systems that include a lr handlers or return ducts located in garages shall have total air leakage of no more than 6% of total fan flow when measured at 0.1 in. w.c. using CalifOrnia Title 24 or equivalents. (CBEES 150.0(o)} 5. Minimum filtration. Mechanical systems supplying air to occupiable space through ductwork shall be provided with a filter having a minimum efficiency of.MERV 6 or better. (CBEES 150.0(o)) 6. Afr Inlets. Air inlets· (not exhaust) shaf! be located away from known contaminants. (CBEES 150.0(o)) 7. Air moving equipment. Air moving equipment used to meet either the whole-building ventllatlon requi-rement or the local ventilation exhaust requirement shalf be rated in terms of airrlow and sound. (CBEES 150,0(o)) a. All continuously operating fans sha!l be rated at a maximum of 1.0 sone. b. Intermittently operated whole-building ventilation fans shall be rated at a maximum of 1.0 sone. c. Intermittently operated local exhaust fans shall be rated at maximum of 3.0 sane. d. Remotely located air.:rnoving equipment (mounted outside of habitable spaces) need not meet sound_ requirements if at least 4 feet ofducl.w'ork between-fan and intake grilL D. Foundation and Underfloor 1. Foundation reinforcement. Continuous footlngs and stem walls shall be provided with a minimum two longitudinal No. 4 bars, one at the top and one at the bottom of the footing. (CRC R403.1.3.3) 2. Shear wall foundation support. Shear waHs shall be supported by continuous foundations. (CRC 403.1.2) 3. Concrete slabs-<,n-grade. Slabs-on-grade shall be minimum 3-1/2Minches thick. (CRC RS06.1) 4. Vapor retarder. A 6-mil polyethylene or approved vapor retarder with joints lapped minimum 6 inches shall be placed between a concrete slab-on-grade and the base course or subgrade. (CRC 506.2.3) 5. Anchor bolts and sills. Foundation plates or sms shall be bolted or anchored to the foundation or foUndation wall per the following (CRC R403.1,6 and CRC R602.11.1): a. Minimum 1/2-inch-dia.meter steel bolts b. Bolts embedded at !east 7 inches into concrete or masonry c. Bolts· spaced maximum 6 f~ on center d. Minimum two bolts per pl8teisift piece with one bolt located maximum 12 inches and minimum 7 bolt diameters from each end of each sm plate/piece e. Min!mum 3-inch by 3-inch by 0.299-inch steel p{ate washer between sill and nut on each bolt 6. Hoki-downs. AH hold-downs must be tied in place Prior ta foundation inspection 7. Protection of wood against decay. Natura.Uy durable or preservative-treated wood shall be provided in the following locations (CRC R317.1): a. All wood in contact with ground, embedded In· concrete in direct contact wlth ground, or embedded in concrete exposed to weather ii. Wood joists within 18 inches and wood girders within 12 inchss of the exposed ground in era.wt.spaces sha!! be of naturaJ!y durable or preservative-treated wood e. Wood framing members that rest on concrete er masonry exterior foundation walls and are less than 8 inches from exposed earth shall be of natur.aUy durab!e or preservative-treated wood d. Wood framing, sheathing, and siding on the exterior cf the building and having clearance iess than 6 inches fran the exposed ground or less than 2 inches vertically from concrete steps, porch slabs, pato slabs, and similar horizontal surface exposed to weather e. Sills and sleepers on concrete or masonry s!ab in direct contact with ground unless separated from such slab by impervious moisture barrier PDS 081 (REV. 01/01/2020) D. Founf1a!ion and Underfloor {Continued) f. Ends of WOJd girders entering masonry or concrete watls with clearances less than 1/2 ittf;h: on tops, sides, and ends g. Wood structural members supporting mcistire-permeable floors or roofs exposed to W§ather, such as concrete or masonry slabs, unless sepa:ated from such floors or ~fs by an impervious moisture barrier h. Wgoo furring strips or other wood framing members attached directly to interior of 61\terlorconcrete or masonry walls below grade except where vapor retarder applied b~tween wall and f..irring strips or taming members 8. Underfloor ventilation. Underfloor areas shall have ventilation openings through foundation walls or exterior walls, with minimum net a•ea of ventilation openings of i square foot for each 150 square feet of underfloor area. On such ventilating opening shall be within 3 feet of each comer of the building. (CRC R408.1) 9. Undurfioor access. Underfloor areas shall be provided with a minimum 18-inch by 24~inch access opening. (CRC R408.4) E. Wood Framing 1. Fastener requirements. The number, slze, and spacing of fasteners connecting wood members/elements shall not be less than that set forth in CRC Table R602.3(1). (CRC R502.9, CRC R602.3, and CRC R802.2) 2. Stud size1 height, and spacing. The size, height, and spacing of studs shafl be in accordance with CRC Table R602.3(5). (CRC R602.3.1) 3. sm plate. Studs shaft have full bearing on nominal 2-inch thick or larger sill plate with width at least equal to stud width (CRC R602.3.4) 4. Bearing studs. Where joists, trusses, or rafters are spaced more than 16 !nc:hes on center and the bearing studs be!ow are spaced 24 inches on center, such members shat! bear within 5 inches of the studs beneath. (CRC R602.3.3) 5. Drilling and notching of studs. Any stud in an exterior wall or bearing partition may be cut or notched to a depth not exceeding 25% of its width_ Studs in nonbearfng partitions may be notched to a depth not to exceed 40% of a single stud width. Any stud may be bored or drilled, provided the diameter of the resulting ho!e is no rrue than 60% of the stud Width, the edge of the hole is no more than 518 inch to the edge of the stud, and the ho!e is not located in the same section as a cut or notch. Studs located in exterior wall or bearing partitions drli!ed over 40o/o and' up to 60% shall also-be doubied with no more than two successive studs bored. (CRC R602.6) 6. Top plate. Wood stud wafls shall be c~9ped with a double top plate installed to provide overlapping at corriers and at intersections with other partitions, End joints in doubfe top plates shall be offset at least 24 inches. Joints in plates need not occur over studs. Plates shall be minlmum nominal 2 inches thick and have width at least equal to width of studs. (CRC R602.32) 7. Top plate splices. Top plate [ap splices shall be face-nalied w!th minimum 8 16d nails on each side of splice. (CRC R602.10.8.1) 8. DriUil"lg and notching oftop plate. When piping or ductwork is placed in or partly In an exterior wall or intenior toad-bearing waH, necessitating cutting, drilling, or notching of the top plate by more than 50°/o of its width, a galvanized metal tie not less than 0.054-inch thick and i-112-inches wide sha!l be fastened across and to the plate at each side of the opening with not less than 8 10d nails having a minimum length of 1-1/2 inches at each side or equivalent. The metal tle must extend minimum 6 inches past the opening. (CRC R602.6.1) 9. Cripple walls. Foundation cripplewa!ls sha!I be framed of studs not less in size than the studding above. Cripple walls more tha.n 4 feet in height shall have studs sized as required for an additional story. Crip~!e wails with stud height less than 14 inches shall be sheathed on at least one side with a wood structural panel fastened to both the top and bottom plates ln accordance with Table R602.3(i), or the cripple walls shall be constructed of solid blocking. Cripple walls shall be supported on continuous foundations. (CRC R602.9) 1.0. Wa!i bracing. Buildings shall be braced in accordance with the methods allowed per CRC R602.10.2. CRC R602.10.4. andiorCRC RSD2.10.5. 11. Braced wail line spacing. -Spacing between braced wall lines shall not exceed 20 feet _cr-alternate provisions of CRC R6□2 'lO.-: .3. 12. Shear wail Ci.mndative length. The cumLi!ative length of shear walls within each braced wall line shall meet the provisions of CRC Tabl~ R602, 10.3(1) for wind loads and CRC Table R602.10.3(2) for seismic !cads !GRC R602.10.1.1) 13. Shear wall spacing. Shearwa!!s shaJ 06 located not more than 25 feet on center. {CRC R602.10.2.2) 14. Shear wali offset, Shear wa;;..; may be offset out-of-plan not more than4 feet from·the designated braced wall line ancl not more than 8 feet from any other offset wal! considered part of the same braced wail line. {CRC R602.10 .1.2) 15. She&r wan location. Shear walls shall be located at the ends of each braced wall line or meet 1he alternate provisions of CRC R602.10.2.2. 16. Individual shear wall length. Shear wa!ls shat! meet minimum length requirements of CRC R602.10.6.5.1. 17. Cripple wall bracing. Cripple wa!is sha!I be braced per CRC R602.10, 11. 18. Shear wall and diaphragm nailing. All shear walls, roof dtaphragms, and floor diaphragms shall be nailed to supporting construction per CRC Table R602.3(1 ). (CRC R604.3) 19. Sheair wall joints. Al! vertical joints in-shear wa!! sheathing shatl occur over, and be fastened to, common studs. Horizontal joints in shear walls shall occur over, and be fastened to, minimum 1-1/2-inch-thick blocldng. (CRC R602.10.10) 20. Framing over openings. Headers, double joists, or trusses of adequate slze to transfer loads to vertical members shaH be provided over window and door openings in load-bearing walls and partitions. (CBC 2304.3.2) 21. Joists under bearing partitions. Joists. under parallel bearing partitions sha!! be of adequate size to support the load. Double joists, sized to adequately support the load, that are separated to permit the lnstallation of piping or vents shall be full-depth solid-blocked with minimum 2-lnch nominal lumber spaced at maximum 4 feet on center. Bearing partitions perpendicular to joists shall not be offset from supporting girders, waits, or partitions more than the Joist depth unless such joists are of sufficient size to carry the addUonal load. {CRC R502.4) 22.. Joists above or below shear walls. Where joists are perpendicular to a shear wall above or below, a rim joist band joist, or blocking shall be provided a!ong the entire length of the shear wail. Where joists are parallel to a shear wail above or be!ow, a rim joist, end joist, or other parallel framing shall be provided dirncUy above and/or be!ow the shear wall. Where a parallel framing member cannot be located dlrectly above and/or below the shear wan, furl-depth blocking at 16-inch spacing shall be provided between the parallel framing members to each side of the shear walL {CRC R802.10.8) 23. Floor member bearing. The ends of each floor joist, beam, or girder sha8 have minimum 1-112 inches of bE!aring on wood or metal and mITTlmum 3 inches of bearing on masonry or concrete except where supported on a 1-inch-by-4-lnch ribbon strip and nailed to the adjoining stud or by the use of approved joist hangers. (CRC R502.6) 24. Floor joist lap. F!oor joists framing opposite sides over a bearing support shall lap minimum 3 inches and shall be nailed together within mlnimum 3 1 Od face nai!s. A •.vood or metal splice with strength equal to or greater than that provided· by the lap is permitted. (CRC R502.6.1) 25. Floor joist-t:o--girder st11pport. Floor joists framing into the side of a wood girder shaU be supported by approved framing anchors or on ledger strips minimum nominal 2 inches by 2 inches. (CRC R502.6.2) 26. Floor joist lateral restraint. Floor joists shall be supported laterally at ends and each intermediate support by mlnimum 2-tnch full-depth blocking, by attachment to fuU-depth header, band joist, or rim joist, to an adjoining stud, or shall be otherwise provided with lateral support to prevent rotation. (CRC R502.7) 27. Floor joist bridging. Floor joists exceeding nominal 2 inches by 12 inches shall be supported laterally by solid blocking, diagonal bridging (wood or meta!), or a continuous 1-inch-by-3-inch sirip nailed across the bottom of joists perpendicular to joists at maximum 8-foot Intervals. (CRC R502,7.1} 28. Framing of floor openings. Openings in floor framing shall be framed with a header and trimmer joists. When the header joist span does net exceed 4 feet the header joist may be a single member the same size as the floor joist Single trimmer joists may be used to carry a sing!e header joist 1ocated wlthin 3 feet of the trimmer joist bearing. When the header joist span exceeds 4 feet, the trimmer joists and header joist sha!! be doubled and of sufficient cross section to support the floor joists framing into the header. Approved hangers shall be used for the header-joist-to-trimmer-Joist connections when the header joist span exceeds 6 feet. Tail joists over 12 feet long shalf be supported at the header by framing anchors or on ledger strfps minimum 2 inches by 2 inches. (CRC R502. iO) E. Wood framing (Continued) 29. Girders. Girders for sing le-story construction or girders supporting loads from a single floor shali not be !ess than 4 inches b":! 6 inches for spans 6 feet or less, provided that girders are spaced not more than 8 fi?lSt on center. Other glrders shalt be designed to support the loads specified in the CBC-Glrder end joints shall occur over supports. When a girder is spUced over a supp!:!ft. an adequate tie shall be provided. The ends of beams or girders supported on masoriry or concrete shali not have less than 3 inches of bearing. {CBC 2308.7) 30. Ridges, hips, and valleys. Rafters shaH be framed to a ridge board or to each other with a gusset plate as a tie. Ridge boards shall be· minimum 1-!nch nominal thickness and not less in depth than the cut end of the rafter. A1 al! valley and hips, there shall be a valley or hip rafter not less than 2-inch nominal thickness and not less in depth than the cut end of the rafter. Hip and valley '"afters shali be supported at the ridg8 by a brace to a bearing partition or be designed to carry and distribute the specific load at that point Where the roof pitch ts less than 3: 12 slope {25% gradient), structural members that support rafters and ceilings joists, such as ridges, hips, and vaileys, sha!! be designed as beams. (CRC R802.3) 31. cemng jOist and rafter connections. Ceiling joists and rafters shal! be nailed to each other per CRC Table R802.5.1 {9), and the rafter shall be nailed to the wall top plate per CRC Table R602.3(1). Ceil;ng joists shall-be continuous or SeCI.D'ely joined perCRC Table R802,5.1 (9) where they meet over interior partitions and are nailed to adjacent rafters to provide a continuous tie across the building when such joists are parallel to rafters. Where ceiling joists are not connected to the rafters at the wall top plate, joists connected higher in the attic shaH be ,nsta3ecl as rafter tles, or rafter tles shall be lnstailed to provide a continuous tie, Whe:-e ceiilng joists are not parallel to rafters. rafter ties shall be. installed. Rafter ties shall be minimum 2 inches by 4 inches nominal, installed per CRC Table R802.5.1 (9}, or connections of equivalent capacities shaA be provided. Where ceilings joists or rafter ties are not provided, the ridge formed by these rafters shall be supported by a waU or engineer-designed girder. (CRC R802.3.1) 32. Ceiling joists lapped. Ends of ceiling joists shat! be lapped minimum 3 inches or butted over bearing partitions or beams and toenailed to the bearing eiement. Where cei!lng joists provide resistance to rafter thrust, lapped joists sha!i be nailed together per CRC Table R602.3(1) and butted joists shall be tied together in a manner to restst such thrust. (CRC R802.3.2) 33. Cof!ar ties. Co!iar ties or ridge straps to resist wind up!lft shall be connected in the upper third of the attic space. Collar ties shail be a minimum 1 inch by 4 inches nominal and spaced at maximum 4feeton center. (CRC R802.3.1) 34. Purlins. PurHns lnstaHed to reduce the span of rafters shall be sized. not less than the required size of the rafters they support. Pur!ins shall be continuous and shall be supported by 2-inch-by-4-lnch nominal braces installed to bearing walls at a minimum 45~degree slope from horlzonta1. The braces shall be spaced maximum 4 feet on center with a maximum 8-foot unbraced fength. (CRC R802.5.1} 35. Rooi/ceiling member bearing. The ends of each rafterorcel!ing joist shall have not less than 1-1/2 inches of bearing on wood or metal and not 1ess than 3 inches of bearing on masonry or concrete. (CRC R802.6} 36. Rooffcemng member lateral support. Roof framing members and ceiling joists with a nominal deptl1-to-thickness ratfo exceeding 5:1 shall be provided with lateral support at points of bearing to prevent rotation, (CRC R802.8) 37. R.oofieelHng bridging. Rafters and ceiling joists with a nominal depth-to-thickness ratio exceeding 6:1 shall be supported. laterally by solid blocking, diagonal bridging (wood or meta!), or a continuous 1-inch-by-3-inch wood strip nailed across the rafters or ceiling jolsts at maximum 8-foot tntervals. (CRC R802.8.1") 38. Framing of roofJcei!ing openings. Openings in roof and ceiling framing shall be framed with a header and trlmmer joists. When the header joist span does not exceed 4 fee~ the header joist may be a single member the same size as the celHng joist or rafter, Single trimmer joists may be used to carry a single header joist located within 3 feet of the trimmer joist bearing. When the header joist span exceeds 4 feet, the trimmer joists and header Joist shall be doubled and of sufficient cross section to support the ceiling jolsts or rafters framing into the header. Approved hangers shall be used for the header~joist-to-trimmer-joist connections when the header joist span exceeds 6 feet. Tai! joists over 12 feet long shall be supported at the header by framing anchors or on ledger strips minimum 2 inches by 2 inches. (CRC R502.10) 39. Roof framing above shear walls. Rafters or roof trusses shaft be connected to top plates of shear walls w[th blocking bei ween the rafters or trusses, (CRC R602.10.8) 40. Roof diaphragm under fill Framing. Roof plywood shall be continuous under Callfomla fil! framing. 41. Roof diaphragm at ridges. Minimum 2-inch nominal blocking required for roof diaphragm nailing at ridges. 42. Blocking of roof trusses. Minimum 2-inch nomlnaf blocking required between trusses at ridge lines and at points of bearing at exterlor walfs. 43. Truss clearance. Minimum 1/2-inch clearance required between top plates of interior non-bearing partitions and bottom chords of trusses. 44. Dri!Hng, cutting, and notching of roof!fioor framing. Notches ln solid !umber joists, rafters. blocking, and beams shall not exceed one-sixth the member depth, shat! be not longer than one-third the member depth, and shal! not be located in the middle one-third of the span. Notches at member ends shall not exceed one-fourth the member depth. The tension side of members 4 inches or greater in nominaf thickness shall not be notched except at member ends. The diameter of holes bored or cut into members shall not exceed one-third the member depth. Holes shall not be c!oser than 2 inches to the top or bottom of the member or to any other hole located in the member. Where the member is also notched, the haie shal! not be closer than 2 inches to the notch. {CRC R502.S.1) 45. Exterior landings, decks, balconies, and stairs. Such elements shall be positively anchored to the primary structure to resist both vertical and lateral forces or sha~ be deslgned to be self-supporting. Attachment sha!! not be accomplished by use of toenails or nails subject ta withdrawal. {CRC R311.3) 46. Firebiocking. Fireblocking shall be provided in the foliowlng locatrons (CRC R302.11 and CRC R1003.19): a. !n concealed spaces of stud walls and partitions, inctuding furred spaces, and para.He! rows of studs or staggered studs, as follows: i. Vertie.ally at the ceiling and floor levels ii. Horlzonta!!y at intervals not exceeding '10 feet b. At all interconnections between concealed vertical and horizontal spaces such as occur at so ff its, drop ceiHngs, and cove cel!ings c. !n concea!ed spaces beti.veen stair stringers at the top and bottom of the run d. At openings around vents, pipes, ducts, cab!es and wires at cei!ing and floor level, with an approved materiai to resist the free passage of flame and products of combustion e. At chimneys and fireplaces per item E.49 f. Cornices d a two-family dwel!ing at the line of dwelling-unit separation 47. Firebiocking materials. Except as otherwise specified in Items E.48 and E.49, fireblocking shall consist of the following-materials with the integrity maintained (CRC R302.11.1): a. T1.YO-inch nominal lumber b. Tv.ro thicknesses of one-inch nominal !umber with broken lap joints c. One thickness of 23/32-inch wood structural pane! with joints backed by 23/32-inch wood structural panel d. One thickness of 3/4-inch particleboard with joints backed by 3i4~inch particleboard e. 1/2-inch gypsum board f. 1/4-inch cement-based millboard g, Batts or blankets of mineral or glass fiber of other approved materials installed in such a manner as to be securely retained in place. Batts or blankets of mineral or glass fiber or other approved non~rigid materials shat! be permitted for compliance with the 10-foot horizontai fireblocking in walls constructed using parallel rO\ll!S of studs or staggered studs. Unfaced fiberglass batt insulation used as fireblocking shall fill the entire cross-section of the wali cavity to a minlmum height of 16 inches measured vertically. When piping, conduit, or slmHar obstructions are encountered', the Insulation sh.al! be packed tightly around the obstrnct!on. Loose-fi!i insulation material shall not be used as a fireblock uniess specifically tested in the fCf!Tl and ma'1f!er intended for use to demonstrate its ability to remain in place and to retard the spread offire and hot gases. 48. Flreblocklng at openings around vents, pipes, ducts, cables, and wires at: celllng and floor level. Such openings sha!! be fireblocked with an approved material to resist the free passage of flame and products. of combustion. (CR.C R302. i 1) E. Wood Framing {Continued) 49. FirebIDcking of chimneys and fireplaces, All spaces between chlmrm·ys and floors and cemngs through which chimneys pass shall be fireb!ocked with noncombustible material securely fastened in place. The flreblocking of spaces between chimn6vs and wood joists, beams, or headers sha!! be self-supporting or be placed on strij)s, of metal or metal !ath iaid across the spaces between combusUble materiaf and the chimney. (C_RC R1003.19) 50. Draftstopping. In combustible construction where there is usable space both above and below the concealed space of a floor/cei!ing assembly, draftstops shall be instal!ed so that the area of the concealed space does not exceed 1000 square feet. Draftstopping shall divide the concealed space into approximately equal areas. Where L}ie assembly is enclosed by a floor membrane above and a ceiiing membrane be!aw, draftstopp!ng shall be provided in iooriceiling assembiies under the following circumsta;1ces (CRC R302.12): a. Ceiling is suspended under the floor framing b. Floor framing is constructed of truss~type open-web or perforated members 51. Draflstopping materials. D;-aftstopping shall not be !ess than 1/2-inch gypsum board, 3/8-inch wood structural panels, or other approved materials adequately suppor..ed. Draflstopping shall be insta!!ed paraUei to t"le floor framing members uniess otherwise approved by the bulk.ling officiai. The lntegr:ity of draftstops sha!i be maintained. (CRC R302.12.1} 52. Combustible insulation clearance. Combustible insulation shal! be separated minimum 3 inches from recessed luminaires, fan motors, and other heat-producing devices. (CRC R302.14) F. Gelleral Material Specific:a!ions 1. Lumber. A!! joists, rafters, beams, and posts 2-inches to 4~lnches thick sha[I be No. 2 grade Douglas Fir-Larch or better. A!I posts and beams 5 inches and thicker shall be No. 1 grade Douglas Fir-Larch or better. Studs not more than 8 feet !ong shall be stud-grade Daugias Fir-Larch or better when supporting not more than one ffoor. roof, and ceiling. Studs longer than 8 feet shall be No. 2 grade Douglas Fir-Larch or better. 2. Concrete. Concrete shall-have a minimum compressive strength of 2,500 psi at 28 days and shall consist of 1 part cement, 3 parts sand, 4 parts 1-inch max:murn size rock, and not more than 7-1/2gallons of water per sack of cement. {CRC R402.2) 3. Mortar, Mortar useo in canstructron of masonry waifs, foundaUon wa~s, and retaining wa!!s shali conform toASTM C 270 and shall consist of 1 partportland cement, 2-114 to3 parts sand, and 1/4 to 1!2 part hydrated lime. (CBC 2103.2) 4. Grout Grout shall conform to ASTM C 475 and shall consist of 1 part portland cement, 1110 part hydrated lime, 2-i/4 to 3 parts sand, and 1 to 2 parts gravel. Grout shall attain a minimum compressive strength of2,000 psi at28 days. (CBC 2103.3) 5. Masoriry, Masonry units shai1 comply with ASTM C 90 for load-bearing concrete masonry units. (CBC 2103.1) 6. Reinforcing steeL Reinforcing steei used in construction of reinforced masonrf or concrete structures shall be deformed and comp!ywithASTMA 615. (CBC 2103.4) 1. Structurai steel. Steef used as structural shapes such as wide-flange sections, channels, p[ates, -and angles shall compiy wtth ASTM A36. Pipe columns sha.li comp!y with ASTM A53. Structural tubes shall comply with ASTM A5DO, Grade B. B. Fasteners for preservative~treated wood. Fasteners for preservative~treated and fire-retardant-treated wood -lncluding nuts and washers --shall be of hot dipped zinc-coated galvanized steel, stafn!ess steel, sillcon bronze, or copper. (CRC R317.3.1) Exception: 112-inch diameter or greater steel bolts Exception: Fasteners other than nails and timber rivets may be of mecrlanically dep.osited zinc-coated stee! with coating weights in accordance with ASTM B 695, Class 55 minimum Exception: Plain carbon steel fasteners acceptable in SBX/DOT and zinc borate preservative~treated wood in an interior, dry environment 9. Fasteners for fire~retardanMreated wood. Fasteners for fire-retardant-treated wood used in exterior applications or wet or damp locations shall be of hat dipped zincMcoated galvanized steel, stainless steel, silicon bronze, or copper. (CRC .R317.3.3) G. Roofing and Weatherproofing 1. Roof covering. All roof covering shail be installed per applicable requi;ements of CBC 1507. Roof coverings shall be at teastC!ass A rated in accordance with ASTN! E 108 or UL 790, which shall include coverings of slate, day or concrete roof tile, exposed concrete roof deck, ferrous or copper shingles or sheets. {County Bui!ding Code 92.1.1505.1) 2. Roof flashing, Flashing shall be instaHed a:twall and roof intersections, at gutters, wherever there is a change in roof slope or direction, and around roof openings. Where flashing is of metal, the metal shall be corrosion-resistant with a thickness of not Jess than O IJ19 inch (No. 26 galvantze!i sheet}, (CRC R903.2.1) 3. Cricl:.tits and saddles. A cricket or sadd!e sha!l be fnstalled on the ridge side cf any chimney or penetratlon more than 30 inches wide as measured perpend icutar to the slope. Cricket or saddle covering shafi be sheet metal or the same materiai as the roof covering. (CRC R903.2.2) 4. Water-resistive barrier. A minimum of one-layer of No. 15 asphalt felt shali be attached to studs or sheathing of afl exterior walls. Such felt or material shall be applied horizontal!y, with the upper layer lapped over the lower !ayer minimum 2 inches. Where Joints occur, feit shall be lapped mlnimum 6 inches. The fe!t shall be continuous to the top of wans and terminated at penetrations and building appendages in a manner to maintain a weaU1er-resistant exterior waff envelope. (CRC R703.2} 5. Wall flashing. Approved corrosion-resistant f!ashing shall be applied shingle fashion at the fo!iowlng locations to prevent entry of water into the wall cavity or penetration of waterto the building structural framing components (CRC R703.8): a. Ex!.:?.rior door and window openings, extending to the surface of the exterior wan finish or to the wateNeslstive barrier for subsequent drainage b. At the intersection of chimneys or other masonry construction with frame or stucco watls, with projecting lips on both sides under stucco copings c. Under and at the ends of masonry, wood, or metal copings and sms d. Continuously above al! projecting wood trim e, Where exterior parches, decks, or stairs attach toa wall or floor assemb!y of wood-frame construction f. At wan and roof intersections g. At built-in gutters 6. Da:mpproofing. Dampproofing matedals for foundation walls enclosing usable space below grade shall be installed on the exterior swrface of the wall, and shaH e:d:en::! from !he top of the rooting to finished grade. (CRC R406.1) 7. Weep screed. A minimum 0.019-inch (No. 26 galvanized sheet gage), corrosion-resistant weep screed or plastic weep screed with a mintrnum vertical attachment flange of 3-112 inches shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 92. The weep screed shal! be placed a minlmum 4 inches above the earth or 2 Inches above paved areas and shall be of a type allowing trapped water to drain to the exterior of the building. {CRC R703.7.2.1) H. Grading and soils 1. Grading permit Gra:d1ng permit required if volume of earth moved exceeds 200 cubic yards or if any cuts or fil!s exceed 8 feet in height/depth. (County Grading Ordinance 202) 2. Compaction report. Compaction report required for fill material 12 inches or more in depth. (CBC 1803.5.8) I. Green Building Standards Code {CAlGreen) Requirements 1. Appllcabl!lty. Cal Green residential mandatory measures shall apply to every newly constructed building or structu,e and within any addition or alteration increasing s building's conditioned area, volume, or size. (CalGreen 101.3, CalGreen 30i .1.1} Exception: All residential buildlngs undergoing permitted alterations, additions, or improvements shall replace noncomp!iant plumb!ng fixtures with water-consenling plumblng fixtures per CaJGreen 301, 1, 1 and CalGreen 4,303,1 I. (CAlGreen) Requiremen!e (Continued) 2. Water conserving riumb!ng fixtures end fittings. P!umbing fixtures and fittings shall comply with the following per CalGreen 4.303.1: a. Water closets: Maximum 1.28 gallons per flush b, Urina!s: Maximum 0.5 gallons per flush c:. Singie showerheads: Maximum ffow rate of 2.0 gal!ons per minute at 80 psi d. Multiple showerheads serving one shower: Maximum combined flow rate of2.0 _gaUons per minute at BO psi e. Lavatory faucets: Maximum flow rate of 1.2 ga!!ons per minute at 60 psi, minlmum flow rate of 0.8 gaHons per minute at 20 psi f. Kitchen faucets:: Maximum flow rate of 1.8 gallons per minute at 60 psi Exception: Temporary increase allowed to maximum 2.2 gal!ons per minute at 60 psi if faucet defaults back to maximum 1.8 gafons per minute at 60 psi 3. Irrigation controllers. Auto:nattc higat'an system controllers for !andscap!ng shall comply with the following (CalGreen 4.304.1}: a. Contro!!ers shall be weather~ or soil moistu:-e-based cantrol!ers that automaticany adjust inrigatlon In response to changes in plants' needs as weather conditions change. b. Weather-based controHers without integral ;ain sensors or communication systems that account for iocal rainfall' shall have a separate wired or wireless rain sensor which connects or communicates with the contra!ler{s}, Soi! moisture-based controllers are not required to have rain sensor input. 4. Joints and openings. Openings in the building envelope separating conditioned space from unconditioned space needed to accommodate utiHty and other penetrations must be sealed fn compliance with the Caiifomia Energy Code. (CALGreen 4.406, 1) Exception: Annular spaces around pipes, efectric cab!as, conduits or other openings in piates at exterior walls sha!I be protected against the passage of rodents by dosing such opening with cement mortar, concrete masonry or a similar method ac~ptable to the enforcing agency. 5. Construction waste reduci:ion, disposal, and recycling. Reduce and/or salvage for reuse a minimum of 65 percent of the nonhazardous construction and demolition deC:ris. (CALGreen 4.408.1) Exception: Excavated soil and !and-clearing debris. Exception: A!ternatewaste reduction methods developed by working with local agencies if diversion or recycle facmties capabie of comp!tance with this item do not axist or are not located reasonably close to the jobslte The County of San Diego, Department of Public Works, Construction & Demolition (C&D) Facilities Gulde is onHne at http:f/www.sdoounty.ca.govfdpwlrecycling!Flles/Construction _ Guide_SJB _ Pgs_ 1 -:27 .pdf. 6. Constructicm was!B management plan. A construction waste management plan shall be prepared and avaifable on site during construction. DocumentatiorJ demonstrating compliance with the p!an shall be accessible during construction for the enforcing agency. (CALGreen 4.408.2) The plan: a. !dentify the construction and demolition waste materials to be diverted from disposal by recycfing, reuse on the project er salvage for futu-e use or sale b. Specify if constructlon and demolition waste materials will be sort ad on,sita (source-separated) or bu!k mixed (singie stream} c, ldentify d1version facilities where the construction and demolition waste materials wiil be taken d. identify ccnstruction methods employed to reduce the amount of construction and demolition waste generated e. Specify that the amount of construction and demolition waste mater!a!s diverted shaii be calculated by weight or votume, but not by both 1. Operation and maintenance manual. Prior to fina! inspection, a msnu&i, compact d[sc, web-based reference, or other acceptable media. which includes an of the fallowifl{;I sha!! be placed in the building (CALGreen 4.410.1 ): a. Directions to owner or occupant that manual shall remain with the bulldlng throughout the \if e cycle of the structure. b. Operation and maintenance inst;uctions for the folfow!ng: i. Equipment and appliances, including water-saving devices and systems, HVAC system, photovoltaic systems, waterMheating systems and other major appliances and equipment ii. Roof and yard drainage, inc!udlng gutters and downspouts. rn. Space conditioning systems, including condensers and air filters. iv. Landscape irrigation systems. v. Water reuse systems. c, information from local utility, water, and waste recovery providers on methods to further reduce resource consumption, including recycle programs and iocations. d. Pubiic transportation and/or carpoo! options available in the area. e. Educational material on the positive impacts of an interior relative h:,,1m;d!ty between 30-60 percent and what methods an occupant may use to maintain t: ~B relative humirnty· Jeve! in that range. f. fnformatlon about water-conservlng landscape and irrigation design a::1d contm!lers which conserve water. g. lnstruct!ons for maintaining gutters and downspouts and the importance af diverting water at ieast 5 feet away from the foundation. h. information on requ:red routine maintenance measures, including, but not limited to, caulking, painting, gradlngar.ound the building, etc. i. lnformation about state so:ar energy and incentive prog;ams available, j. A copy of al! special inspection verifications required by the enforcing agency or code. 8. Coverf11g of duct openings and protection of mechanical equipment during con1S±ruct!on. At the time of rough installation or during storage on the e-onstruction slte and until final startup of the heating and cooling equipment, afl duct aro cj-ier related alr distribution component openings shall be covered with tape, plastic, sheetmeta! or other methods acceptable to the enforcing agency to ~educe the amount of dust or debris which may collect in the system, (CALGreen 4.504.1) 9. Adhesives, sealants, cauiks, paints, and coatings poi!utant control. Adhesives (including carpet adhesives), sealants, cauiks, paints, and coatings shali comply with voe '.imits per CALGreen 4.504,2. Verification of compliance shall be provided at the request of the enforcing agency. (CAL Green 4.504.2.1) 10. Carpet systems. All carpet installed ln the building interior sha!! meet the testing and product requirements of one of the following (CALGreen 4,504.3): a, Carpet and Rug lnstitute's Green Label Pius Program {ail carpet cushion must meet the requirements of this program), b. Ca!iforn1a Department of Public Health Standard Practice for the testing ofVOCs (Specification D1350). c. NSFIANSi 140 at the Gold lavei. cf. Scientific Certifications Systems Indoor Adva11tage™ Gold. 11. Resment flooring systems. At least 80 percent of the floor area receiving resiHent flooring shall comply with one of or more of the following {CALGreen 4.504.4): a, voe emission !imits defined in the Collaborative for High Performance Schools (CHPS) High Performance Products Database b. Products compliant with CHPS criteria certified under the Greenguard Chiidren & Schools program c. Certification underthe Resilient Floor Covering Institute {RFCO FloorSco~e program d. Meet the California Department of P!Jblic Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1. 1, February 2010 falso known as Specification 01350) 1·2. Composite wood products Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the Interior or axt.erfor of the buiiding shal! meet the requirements for formaldehyde as specified ln ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.) by or before the dates specified fn those sections, as shown in CalG;een Table 4.504.5. The following Umits are in parts per million (CALGreen 4.504.5}: a< Hardwood plywood veneer core b. Hardwood plywood composite core c. Particle board d. Medium-density fiberboard (MDF) e. Thin MDF (5116 inch or less) 0.05 0.05 0.09 0.11 0.13 I. (CALGreen) Requirements (Continued) 13. Moisture content of building materials, Building materials with visible signs of water damage shali not be installed. Wa!l and f!oor framing shat! not be enclosed when the framing members exceed 19 percent moisture content. Mo!sture content shail be verified in compliance with the following (CALGreen 4.505.3): a. Moisture content sha!l be determined with either a probe-type or contact-type moisture meter. b. Moisture readings shall be taken at a point 2 feet to 4 .feet from the grade stamped end of each piece to be verified. c. At !east three random moisture readings shat! be pOOormed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wan and floor framing. Insulation products which are visibly wet or have high moisture content shall be replaced or a!lowed to dry prior to enclosure in wall or floor cavities. Wet,applied insuiatfon products shall fo!fow the-manufacturers' drying recommendations prior to enclosure. 14. Bathrooms with a bathtub and/or shower shall be mechanicaUy ventilated per the following (CalGreen 4.506.1): a. Fans shall be ENERGY STAR compliant and ducted to terminate outside buitding b. Unless functioning as a component of a whole-house ventilation system, fans sha!! have humidity controls capable of adjustment -manual!y-or automatically --between a relative humidity range-of 50% .to 80%. 15. Heating and air-conditioning system design. Heating and air-conditioning systems shall be sized, designed, and have thelr equipment selected using the following methods (CALGreen 4.507.2): a. The heat loss and heat gain is established accord[ng to ANSl/ACCA 2 Manua! J, ASHRAE handbooks, or other equlvalent design software or methods. b. Duct systems are sized according to ANS!/ACCA 1 Manua! D 2009, ASH RAE handbooks, or other equivalent design software or methods. c. Select heating and cooling equipment according to ACCA 36-S Manual Sor other equivalent design software or methods TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS • > , Sh~ I, ":-c:,•.,~°"' , .. 't p:s,, ~ ,, .,,,,, -a<(' p~;e ' ::I':~ MS'A>mG',~;i'F.,!"'1 ! :-:c ,. ii:-",,• , .. ···--:· ... " ,, I .. '"" '. - - '" ,_;,_i,a,-~~ ,v,:,~ - . '-'!i19UI-.!;~ """ 1.11' '""'""~~ .. , . ------·· -; ___ ·-,,_, - J . I ,·,o, ·••;:,,, &., ,,-,n "'"'''-'""'' ;,r-;,,, ,"-' 4m,,,,"°-~"''"'''·'""'-·u,~,\or¥-~• ,,·, •a,Ci,-,,,-c ~,~.:,;,,.,-,,,, \,-r.ci-.e< """"""'"''°"';' ,e,:.,_"'I, •.i••••~:;"'• ;.,a;c,·"'""'"~--,, ''"•h' "'"'"''""'-'-';ow;;,;,~,, ~~'"'"'l""""""':\t ""'""" ~ ;:,c,.b" 1 ;t,,,,,'t<.,~;r<,.De-,.( ,•(,x~;; /so; W-".f<• cTHESE ARE'illl.NIMUM'REl:JWIREMENTSA.NO:• SHALL•No.r.sue'ERSEDE.MGRE RE&TRJC:riVEi , •. • se.EC1FieA,10Ns oil JliE PLANS ciR'M. •.•· · · ; iRE!ll!IIR,EJJ; ~ A~~~t:)\)3~ ~a.:: z -:E Sheet Number CS-1 CERTIFICATE OF COMPUANCE Project Name: Pavaghadi calculation Description: Pavaghadi Calculation Date/Time: 2021-05-17T11:02:02-07:G(J Input Fif.e Name: Pavaghadi.ribd19 CFlR-PRf-0-lE (Pagelof7} GENERAL INFORMATION 01 02 " "' 06 " 10 14 16 ,. w Project Nam I! Pavaghadi Run l!tle l¾!wghadi Project Location 624 Laguna Or. Ciey Carisbad, CA C:lirrnite Zone 7 Building Type Single family Project Salpe AdditionOnly Addition COnd. Floor Area (tt2) ,908 Existing CClnd. Floor Area (fti) 980 Total Cond. floor Area ~ 1888 AOU Bedroom Count 'nja Is Natural GaScAv.iilable? Yes OS 07 09 ll Standarcl5 Versioo :Wf9 Sottm,re Ve!"$ion cs~cc-Re~ Wl.9.1.3 Front Orientation (deg/ Cardinal) l8Q Num~&ofDwellini:;Units 1 Number oflledrooms. 4 NumberofStories 1 Fenestr.ition Aver.1,g,HJ-factar 0.3 Glazing Percentage (,ii} 7.0~\% ADU Conditioned floor Area n/~ Adcriti,;m Alone Project Malysls Parameters 01 02 04 " ~/sting Area (excJ. new additkmJ lft2) Addition Area (e~d. exi!itmgr/ftZ) Total Area fft2) Existing Seo rooms Addition Bedroom~ Total Bedrooms ,., 908 "" 4 COMPLIANCE RESULTS 01 Building Complies with Compumr P,,rforman.:e " This buildlnginoorporatesfe.rturesth.rt require field ~stingan<J/orverification bya certified HERS rater"underthe wpenrision of a CEC-approved HERS pro!lider. " &uilding does not lni;orporate Spetfat fi;=atures Registration Number: 421-P010071121A-OOO.OOO-OOOOOOO-OOOO _ Registration Date/Time: 05/17(.2021 18;00 _ HERS Pro\iider: CHEERS NOTICE: n,,, ,:""""'""/ ha,: i;;,(lr. 90,,sr~tad t;-CDeSo, Ham~ e-not,Y l'i'lf1c1"'1C)" R,mng SJ-M= s., .. = Jo~ (C>iffl/S) ""111!] ir-H,m,11!/M ~pfcs,J~d hJ' tf/.'/'d ,,.,,,,.,,, ""' .>fflliaMd .~;,/, ar ,..~,,,,, ta CIF...El$. Tl,""'f"'•· C/£ERS 1$ net r,,sp,;osu,.i,, fw. iN>d c,annoi u,,ar3o/,,,,, tho -'='7CJ' er c,,m-,>n~s,; af th~ .,r.,,m3ttan r,,,n!3/""'1 It, l.~.-s d=:men: CA Building Energy Efficiency Standards -2019 Residential Compliance Report \/er.ion: 2019.1.300 Reporl, Generated: 2021.05•17 18:02.:47 Schema Version: rev 20200901 CERTIFICATE OF COMPUANCf Project Name: Pavaghadi Calculatron Description:. Pavaghadl Calculation Date/flme; 2021-05-17T11;02:02-07:00 Input file Name: Pavaghadi.ribdl9 CF1R-PRF-01E {Page 4of7) OPAQJJE SURF~ CONSTRUCTJOl'IS 01 02 03 04 OS 06 07 " Interior I Exterior Construction Name Surlate Type ConstructiOll Type, fr.imlng T<ru!I Cavity R•value Continuous U-factor R-212X6 fatsrior WaH, Wood Framed Woll 2~6@ 161n. o. C. R-wlue R-:Zl None/ Norte 0.066 lnsids Finish: Gypsllm Board Ca~ity / F,ime: R-2.1 / 2x6 Exterior Finish· Wood Siding/sheathing/decking Cathedral cemrrg Cathedral Ceilings Wood Framed Ceilin~ ft-30 None/ None 0.042 Hoofing: Light Roof (AsphaltShini.Jc] Roof Deck: Wood Sldlnefsheat:hing/decklng Cavity/ Frame: R-30 / 2K4 T□p Ch.rd Inside Finish; Gypsllm Board woo Ii Floor crver Crawl Auors.Over Crawlspace Wood Framed Floor None/None 0.045- Floor Surfaee: Carpeted Floor Deck; Wood Sid ing/sh~thine/cleding l:allity / Frame; R-19 / 2d2. BUILDING ENV£t0PE-HERS VERlfJCATJON 01 02 04 Quality Jnsulatl011 Jnstl'dlation {QIJ) High ll-,mlue Spray Foom lll!iUlation Builcling EnMelope Air Leakage CFMSO NotReq1.1Jred Not Required WAJE!l HEATING SYSTEMS 01 Name OHWSystem 1 02 System T\IP'e D<lmestlc Hot water (DHW} Distribution Type Srnndard Distribution ,,.,rn 04 OS 06 07 Water Heater Name {II} Solar Heating System Compact Olrtribution HER!iVerifiation Nlll'"ltz NRC711-DV·NG {1} n/a None o/a Registration Number: 421-P010071121A.COO-OOO-OOOOOOO-OOOO Registration ~e/Time:: 05/171202118-:0D . HERS.Pro~lder: CHEERS ~'f!.J:'f,1.";'),'::;,:0~$~"/!,f/'~~",/.~:;{.,'::;,S:) ::;,pt,~;g %~{,,'::,1/::k, sr:,,;~;:J~'~~S) vsmg r~f,;ro,r,fi= ~pl,;adl'Q l>y ,Md p~rt.',~ n,;,t .,tf,J,r,t«! 'mtll c; r~1'>.-,,,J 1a Ci,w,S 11,,.,.,!a,~. C.'lffRS r. r.at CA Building Energy Efficiencv Standard~ -:Z019 Residential Compliance !<eportVersion: 2019.1.300 Report Generated: 2021-05-17 18:02:47 Schema verslon: rev :W20M01 2019 Low-Rise Residential Mandatory Measures Summary NOTE: low-rise residential buildings subject to the Energy Standards mustcompfy with all applicable mandatory measures, regardless of th€ compliance approach used .• ~eview the respective section for more information. 'Exceptions may apply. 01/2020 Building Envelope Measures: § 110.6(a)1: § 110.6(a)5: § 110.S(b): § 110.7: § 110.8(a): § 110.S(g): § 110.B(i): § 110.80): § 150.0(a)c § 150.0(b): § 150.0(c): § 150.0(d): § 150.0(ij: § 150.0(g)1: § 150.0(g}2: § 150.0(q): Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doOJS must limit air leakage to 0.3 CFM ?er square foot or less when tested er NFRC400, ASTM E283 or PJiMAfWDMA/CSA 101/I.S.2/A440-201i." LabeliAg. Fenestration products and e~rior doors must have a label meeting the requirements of§ 10-111(a). Field fabricated exterior doors and fenestration products must use Li-factors and solar heat gain coefficient (SHGC) va[ues from Tables 110.6-A, 11-0.6-B, or JA4.5 for exterior doors. The must be caulked and/orweafuer-stri ed." Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stri ed. Insulation Certification by Manufactur-ers, Insulation must be certified by the Department of Consumer Affairs, Bureau of Househo!d Goods and Services HGS . Insulation Requirements for Heated Slab Floors. Heated sfab floors must be insulated per the requirements of§ 1 to.8(g). Roofing Products.Solar Reflectance and Thennat Emittance. The thermal emittance and a9ed solar reflectance values of the roofing materiaf must meet the re uirements of 110.B i and be labeled er 10--113 'Nhen the installation of a cool roof is s ecifled on the CF1 R Radiant Barrier. When required, radiant barriers must haVB an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulalion in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-1g or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed-to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiffng which is sealed to limit infiltration and exfi!tration as specified in § 110.7, inducting but not limited to placin insulation either above or below the roof deck or on top of ad; wal! ceilin .• Loose-fill Insulation. Loose fill insulation must meet the manufacturer's· required density for the labeled R-value. Well Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factorof 0.102or less, or R~20 in 2x6 inch wood framing or have a LI-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls must meet Tables 150.i-A or B.· RaiseMioor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum LI-factor: Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, rro greater than 0.3 percent; have a water vapor penneance no r..ater than 2.0 penn per inch; be protected rrom physical damage and W light deterforation; and, when installed as part of a heated slab floor, meet the requtremenls of§ 110.8(g). Vapor Retarder. In climate zones 1 through 16, the earttl floor of unvented crawl space must be covered wrth a Class I or Class I! vapor retarder. This r uirement also a lies 1o controlled ventilation crawls ce for build in s com I in with the eKC tion to 150.0 d Vapor Retarder. In crimate zones 14 and 16, a Class I or Class It vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented atti~ with air-penneable insulation. Fenestration Products, Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum LI-factor of 0.58; or the weighted average LI-factor of all fenestrafion must not exceed 0.58." Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 110.S(e] Pilot Light Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. § 150.0{e)1: Closable Doors, Masonry or factory-built fireplaces mu.st have a.closable metal or glass door covering the entire opening of the firebox. § 150.0(e)2: Combustion Intake. Masonry or factol)'-built fireplaces must have a combustion outside air intake, which. is at least six square inches in area and is ui ed with a rt,adil accessible, o erable, and ti ht-fitti dam r or comMl:fOn-air control device.· § 150.0(eJ& Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessibfe control: Space Conditioning, Water Heating, and Plumbing System Measures; § 110.2(b): § 110.2(c): § 110.3(c)4: § 110.3(c)6: § 110.5: § 150.0(h)1: Certification. Heating, ventilation and air conditioning (HVAC) equipment, W41er heaters, showerheads, faucets, and all other regulated a liances must be certified b the manufacturer to the California. Ene Commission: HVAC Effieiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K: Controls for Heat Pumps with Supplementary Eledric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have,contro/s that prevent supplementary heater operation when the heating load can be met by the. heat pump alone; and in which the cut-on temperature for compression heating is higher than the cut<in temperature for supplementary heating, and the cut--0ff temperature for com ression heatin is hi her than the cut-offtem erature for su lementa heatin ." Thennostats. All heating or cooling systems not controlled by a centr.a! energy management control system (EMCS) must have a setback ihermostat.· Water Heating Recirculation Loops Serving Multiple Dwelling Units. Wster heating recirculation loops serving multiple dwelJing units must meet the air release valve,backflow prevention. pump priming, pump isolation valve, and recirculation loop conneciioa requirements of 110.3c4. Isolation Valves. Instantaneous water hootm; with an input rating greater than 6.8 kB tu per hour (2 kWj must have isolation valves with hose bibbs or oilier fillings on both cold and hot water lines to a!low for flushing the water heater when the valves are closed. Pilot Lights. Conlinucusly burning pilot lights are prohibited for natural gas: fan-type central furnaces; househofd cooking appliances (except appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour); and pool and spa heaters.· Building Cooling and Heating Loads. Heating am:J/or cooling loads are calculated in accordance with the ASH RAE Handbook, Equipme11t Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards Manual; or the ACCA Manual J usi119 design conditions specified ir. § 150.0(h)2. CERTIFICATE OF COMPUANCE Project Name: Pavaghadi Calculation Description: Pava_ghadi Calculation Date/Time: 2021-05-17f11:02:02-07:00 In~ File Name: Pavaghadi.ribd19 ENERGY USE SUMMARY CF1R-PRF-01E (Page2 of7j Energy Use (kTDV/ft'-vrJ Standard Design Prop05ed Design Compliance Margin Perce1at lmprn-11ement Soace Heating Space Cooling IAQ Ventilation Water He,ating 02 16.78 0.41 15.74 ' 20.95 -0.21 1.0' 0 -lOS 6.2 self Utilization/Flexibility Credit Compliance EnergyTot.i:I 0 11.44 o/a 39A2 0 37.11 '·" 0 Bl ,., nh ,., REQUIRED SPfOAL FEATURES The following are features that must be installed as oom:htion for meeh~g the modeled-eiie,;gyperfo~m,ce forth is computer analysis NO SPECIAL FEATURES REQUlelED HERS FEATURE SUMMARY Tl"le following is a summary of the featLlres that mu51 befield-11<arified by a certifoad HERS R.rter as a condition for me<:atmg the modeled ene:r!IY ~rfurmam:e forth is oompl!ler analyais. Additional detail ls provided in the bulldn,:tables below. Re5istered CF.!Rs and CF3Rsare required to be completed in the HERS P.e,ai;try Building-level Varificat,ons: Kitche~ range hood Cooling Sy&tem VerifiC3tions: Verified Refri~erant Charge HeatingSysrem Veri:'lrations: -None - HVAC Distribution System Veri!icst,on~: -None - Domestic Hot Water System Verifo;ations: --None- ZONE INFORMATION 01 02 oa 04 o.5 06 "' ZorieNarne Zone Type HVAC SVstem Name Zone floor Anra itt'J A.vg. Ceiling Height Water H<lating System 1 water Heating Syst<lrn Z Main Conditioned HVACSystern ,og ' DHW System 1 N/A Registration Number; 421-P010071121A.OIW-OOO-OOOOOOO-OOOO Registration Oate/Tlme: 05/17.1202118:00 HEflS Provkler: C~EERS NOT/Ci:: Tlrio doc11,.,,;,rt ~1ts _,, 'J'M'ilt21M t;y Cc,,Sei li<>m<> £,-,;;-E."'-=!M:cy R3ffn,; sr-s•~m Se,v,=s, '""· (CHcl:.~S) ,,_,,;-,g l'tWm3/."'-' i,p/M(/e,t ~y /t1i,,t ;,am,,.s not ~lfi1mro<i with ,,.,-fflauxi r,, CHffRS. '1>ersf"'c. Cf/URS is. "Ct '=nsi/1/e flX. and c.,~n~r ~.,..,,,.,,,,,._ ,i,,, a<,c,m,cy"' "'""'I>'""'''"'" ,,r IM wa,ma."ior. ,;n.7/afmM '" mis Ct=•:rMnl CA Suildlng Energv Efficiency Stanciard5-2019 Residential Compliance Report Version: 201S.1.300 R.eport Generate<i: 202.1.-0S-17 18:02:47 .S~hema Version: te"Jt 2020[)901 CERTIFICATE OF COMPUANCE Project Name: Pavaghadi Calculation Description: Pavaghadi caku!ation Date/Time: 2021-05-17Tll:02:02-07:00 Input File Name: Pavaghadi.ribd19 CF1R-PRF-01E (Page 5 of7) WATER HEATERS 01 Noritz NRC711- DV-NG Hi,ating Element ,.,e 03 Tank Ty))(! Consumer lnstantaneou:. ... Units OS Tank Vol. jgal) 0 " Enerxv Factor or Effidency 0.89-UEF Input Rating or Pilot "'"'200 kBtu/hr 08 Tank Insulation R-value {lnt/ElCI:) 0 09 Standby Loss or l!Jecovery Eff c/a 10 tstHr. Rating or Flow Rate NEEA Heat Pump Sr.,nd or Model 12 Tank Location orAm~ient Condition c/a 1.3 t-lew Verified Existing O:,ndition WATER HEATING HERSVEFl:l~JCATION 01 02 03 "' Pipe 1nsulati011 Parallel Piping OS ; Compad: Distribution T.,, Recirculation Control 07 Ce,itralDHW Distri~trt:ion 08 Shower Orain Water Heat Recave,y DHW sv,tem 1-1/1 Not Required Not Required Not Required None Not Required Not R,equ1red Not Required SPAC£ CONDITIONING SYSTEMS 01 Name System Type Heat pump heating cooling 03 04 Heatini. Unit Cooling Unft Nam" Name Trane High Effitiency 4MXW9509 AlOOO Trane High Efficiency <IMX\ii.19509 AlOOO OS Fan Name 06 Distribution Name 07 Required Thermostat '""' 08 '<w 09 10 ,.,crified Heating Existing Equipment C0Mlltlo11 count " 11 Coaling Equipment Count Registration Number: 421-P010071121A-□O(J..00M000000-lliJOO Registratio~ Date/Time: 0:5.'17/202118;00 HERS Pr011ider: CHEERS NO~CE-"'" ~-o,~nt ~JSMM r7""""·'"'" bf CMS,,/ Imme En,-,11,vfo(ffdeocyR.1."in/i Sysw,, &r,/a"", Ina {CHITRS) "'"'ti iOfct11'8rlM ~,>,""8ded bY'"-"'1 p~t,<M Oatatf}q~/"'1 wiM cr-r~laiM le CHE!>"$. '/1,e.-.far,,, CHEf!IS!soo, ro,po,,sl!,/e fer, aM =M gu,-.,,mtM, /~e-•'""'''•''1' er CM>P.,,r<mo<s ~, t~e ,r.r.,,,,,,,r,cn <cai!lmr>ed ,n :n,s dOC'..1m~e1 CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2.019.1.300 Report Generated: 2021-05-17 18:02:47 Sdierria Version, rev 2.0200901 § 150.0(h)3A: § 150.0(h)3B: § 150.0U)1: § 150.0ti)2A: § 1so.ou)3: § 150.0(n)1: § 150.0(n)2: § 150.0(n}3: 2019 Low-Rise Residential Mandatory Measures Summary Clearances. Air conditioner and heat pump ou1daor condensing units must have a clearance of al least five feet from the outlet of any dryer Liquid Line Drier, Aircondi~oners and heat pump systems must be equipped with flquid line filter driers if required, as speclfied by the manufacturer's instructions. Storage Tank Insulation, Unfired hot v.rater tanks, such as storage tanks and backup storage tanks for solar water-heating systems, must ha,,e a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water Piping, Solar Water-beating System Piping, and Space Conditioning System Line Insulation. All·domesUc hot water pip[ng must be insulated as specified in Section 609.11 of the California Plumbing Code. Jn addition, the following piping conditions must have a minlmJJm insulation wall thiC:kness of one inch ora minimum insulation R~value of7.7: the fl mt five feet of cold water pipes from the storage tank; all hot water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less than 3/4 inch that is: associated with a domestic hot water recirculation system, from th€ heating source to storage tank or between tanks, ~-uried below grade, and from the heating source to kitchen fixtures.• Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind as required by Section 120.3{b). Insulation exposed to weather must be water retardant and protected from UV fight (no adhesive tapes). lns-1lalion covering chiiled water ojping and refrigf)rant suction piping_ located outside the conditioned space must include, or be protected by, a Class I or Class I! vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve. Gas or Propane Water Heating Systems. Systems using gas or propane water heaters ta serve individual dwelling units must include all of the following: A dedicated 125 volt 20 amp electrlcal receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, within three feel of the water heaterwit,'mut obstruction. Both ends of the unused conductor must be labeled with the word "spare' and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker for the bra11ch circuit and labeled with the words "Fu~Jre 240V Use"; a Catego;y Ill or IV vent, or a Type 8 vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than !'No inches higher than the base of the water heater, and allows natural draining without pump assistance: and a gas supply nne with a capacity of at least 200,000 Btu per hour. Recirculating Loops. RBcirculaling loops serving multiple dwelling units must meet the requirements of§ 110.3(c)5. Solar Water-heating Systems. Sc»arwater-heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC), the International Associatioo of Pfumbing and Mechanical Officials, Research and Testing (IAPMO R&l), or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: Ducts. Insulation installed on an existing space-condrtioning duct must comply with § 604,0 of the California Mechanical Code (CMC). If a § 110.S(d)3: contractor installs the insulation, the contracto~ must certify to the customer, in writing, that the insulation meets ihis requirement CMC Compliance. All air-distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605,0 and ANS!ISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and plenums must be insulated lo a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely ln conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible duels must be § 150.G(m)1: mechanically fastened. Openings must be sealed with mastic, tape, or olher duct-closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1816 or aerosol sealant that meets. the requirements of UL 723. If mastic or tape is used to seal openings greater than¼ ITT ch, the combination of mastic and either mesh or tape must be used. Building cavities. support platforms fer air handlers, and p!enums designed or constructed with materials olher!han sealed sheet metal, duct board or flexible duct mus: not be used to convey c.ondilioned ;J.ir. Building c::ivities and support platforms may contain ducts. Ducts installed In cavities end support platforms must not be compressed to cause recudions in the cross-sectional area." § 150.0(m)2: § 150.0(m)3: § 150.0(m)?: § 150.0(m)B: § 150.0(m)e: § 150.0(m)10: § 150.0(m)11: § 150.0(m)12: § 150.0(m)13: Factory-Fabricated Duct Systems. Factcry-fabricated duct systems must comply with applicable requirements for duct construction. connections, and closures; joints and seams of duct systems and !heir components must not be sealed with doth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field~Fabricated Duct Sy.stems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensifive tapes, mastics, sealants, and other requirements specified for duct construction. Back draft Damper. Fan systems that exchange air between ihe conditioned space and outdoors must have backdraft or aulolTiatic dairipers. · Gravity Ventilati<>n Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in al! openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipm~mt maintenance, and wind. Insulation exposed to weather must be suitable for-outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides sbielding from solar radiation. Porous Inner Core Flex Duct. Porous inner core fiex ducts must have a non-porous layer beti.reen the inner core and outer vapor barrier. Duct System Seafing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiabla space, the ducts must be sealed and duel leakage lested, as confinned through field verification and diagnostic testing. in accordance with§ 150.0(m)11 and Reierence Residential Appendix RA3. Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or equivalent filters. Filters for spare conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure drops and labeling must meet the requirements ln §150.0(m)12. Filters must be accessible for regular seNice.* Space Conditioning System Airllow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole fort he placement of a static pressure probe, or a permanently installed siatic pressure probe in the supply plenum. Airflow must be ~ 350 CFM per ton of oominal cooling capacity, and an air-handling unit fan efficacy :S 0.45 watts per CFM for gas tJrnace air handlers and :S 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow~ 250 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy::; 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.' CERTIFICATE OF COMPLIANCE Project Name: ?ava!-;hadi Calculation Description: Pavaghadi Calculation Date/Tim11: 2021-D5-17Tll:02;02-07:00 Input File Name: Pavaghad1.ribd19 CflR-PRF-OlE (Page 3 of7) OPAQUE SURFACES 01 Name Fmnt teft Back Right Floor over Crawlspace 1 02 :Zone Main .\.lain Main Main 03 Construction R-21 2X6 R-212X6 R,212X6 R-2:12X6 1Nood Floor over Crawl 04 A>irnuth 0 c/a OS Orientation Gr05sArea(tt2) Front Left 320 Left 56 '"' 07 Window and Door Area(fa) " 0 0 11/a 08 09 Tilt (deg} Wall Exceptior,s so 00 ncne New none '°w SQ none New a/a OPAQUE SURFACES -CATHEDRAL CEIUNGS 01 Cathedral Ceiling l Cathedral Ceiling2 "' Zone Main Main FENESTRATION / GLAZING 01 Name 3040 6040SGD " Con,:;truction C~thedral Ceiling Cathedral Ceiling 02 Window Window Windc-w 06 Allmuth Orientation Left 4S4 90 Right 4S4 03 Surfa<.:e Orient.it ion A2imuth Front Front 130 Front rmnt Back 0 0, " Skylight Area Roof Rise (x in (ft2) 12) 0 ' 0 12 06 07 08 09 Width H"ight (It) (ft) Mult, 4 " 16 "' """ Reflectance O.l 0.1 10 11 LI-factor 0.S NFRC 0.3 NFRC 03 NHIC 10 Roof Emittance 0.85 o.gs 13 SHGC SHGC Sour~ ' 0.23 NFRC 0.23 NfRC ll Cool Roof Exterior Shading Bug Screen Blig Screen O.Z3 NFRC Bug Screen Registration Number: 421-P01007112'.A-OOG:000-0000001J::OOOO _ Registr,;t;on Date/Time: 05117(.2021 1-8;00 HERS Provider: CHEERS .\/01(~--rm:. -~"'"''' fas bo•n ll'"'""'w ~y C~nSr,1 ,.._mo li:r,e:·gy eit,""'1cy &u,,11 S'4om ;s~r,•,,:,,,s, Inc. /CHE/:RS,1 <IS<"'/ warmr,//"1> """'"-'c!c!l ll)" M,•d psN/£~ ~a/ .,,,,;;_-,~,; ..-,rn M" c,1~/M ,a CH!o$S. r,~,em,6, CHE1ons 'S nN -.spaW,111, ro,. 8"'1 ""'""' g.,,,r,n:a•. tho .,cc,;,aq o, r;ompie,"ene5"' ~//~elqfors,"1mo "r=>,amed m ,q,. c=m~m. · CA Building Energy Efficienc,1 Standards -2019 Residential Compliance Report Version: 2.019.1.31W Repo_.t Generated: 2.021-05-17 lB:02:47 Sch.em a Version, re1t 10200901 CERTIFICATE OF COMPLIANCE Project Name: Pavaghadi Calculation Description: Pavaghadi calculation Date/rime: 2021-05-17T11;02:□2-07:00 Input File Name: Pavaghadi.rlbd19 CF1R•PRF-01E (Page 6 of7) HVAC. -KEAT PUMPS Name Trane High Efficiem:y 4:V:XW9509A1000 Ductless M<niSplitHP 03 OS "' 07 Heating Cooling Number of Units 1-c==c:-r--c-cc--r-c,---cc--l--==--r------, HSPF/COP Cap 47 C..p lJ SEHi EER/CEER 1 10 '300 swo 14.S 27 0, Zonally Controlled Not 2onal 10 Compressor ,,,,,, Single Speed 11 HERS VerifiC3tion Trane Hi.;h Efficiency 4MXW9S09-Al000- hc,r,-htpomp HVAC.HEAT PUMPS· HERS VERIFICATION 0, 02 03 "' ·os "' Name Verified Airflow Airflow Taarget Verified EER : yerffied SEI_R Verified Refrig.,rant °''"'" Verified HSPF Verified Heatin,: Cap47 Verified Heating Capl7 Trane High Efficiency 4M XW95-09A100Q. hers-ht pump Not Required 0 Not R>cquired Not ~\"quired " PROJECT NOTES Contractor/owner Sllall ver>fy all conditions in the field for as.built constroctioil not ·,eadil'{visOle, and shaU investigateframinP, members. inoul;ition,arY.i mechanical e:ement5 to verify c,,;istsncc. size and direction.All modelin8 data is ~ssumed u, be reliable as supplied by owner/"°ntractor. No liability shall be ass.,med l:iy Dynamic Energy Title 24, or D.cskin Building Design; contractor and owne( snoll W!rify au building conditions Regts!ration Number: 421-P01007112iA,OO!l--000.0000000-00DO Registration □at-efnme, 05117/2021 18;0D HERS Provider: CHEERS ~0~1.,CJ,:/f'1~t:::;:,:.;-,,:~ct;,":,.;f!::,,"'t,;:i ,,;l:,,~";5:/ ~~~1::-.:; %'/'i:f/:"/[,;:,;1;,:.~/f;;,,~;,,~~";.~r/~;,1,~s; O<mg,n(r,m:;:.v,,,, u~od<Nf by '"'"' µ,,,,,. ""' aff'1,.tlt,d ,.,Jt, Gt ;c/O/c<f '" CHff/ZS Tn~"'"''"· CHEERS, .. not CA Building EnergyEfficiem:yStandards -2019 ResidentiafCampliam:s flepor:: Ve1'-ion: 2019.1.300 R-eportGenerated: 2021-05-17 18:02:47 Schema Version: rev 20200901 2019 Low-Rise Residential Mandatory Measures Summary Requiremeri:s for Ventilation and Indoor Air Quality: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASH RAE Stancard 62.2, Ventilation § ! 5o.O(of 1: and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. § 150.0(o)1C § 150.0(o)1E: § 150.0(o)1F: § 150.0(o)1G: § 150.0(o)2: Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airrlow provided at rates detennined by ASHRAE 622Sections 4.1.1 and 4.1.2 and as specified in§ 150.0(o)1C. Multifamily Attached Dwelling Unit.s. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in accordance with Equation 150.0-B and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced system is not used, .all units in the building must use the same system type and the dwelllng-unit er.velope leakage must be ::; 0.3 GFM at SO. Pa (0.2 inch water) per square foot of dwellir19 unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8. Multifamily Building Cenlral Ventilation Systems. Central ventilatiO!l systems that serve multiple dwelting units must t:e balanced to provide ventilation airflow for each dwelling unit served at a rate equal to or grealer1han the rate specified by Equation 150.0-B. All unit airflows must be within 20 ercent of the unit with the lowest a!rAow rate as it relates to the individual unit's minimum re uired airflow rate needed for com liance. Kitchen Range Hoods, Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASH RAE 62.2. Field Verification and Diagnostic Testing. Dwe!lfng unit ventilation airflow must be verified in accordance with Reference Residential Appendix RA3.7. A kitchen range hood must be verified In accordance with Reference Residential Appendix RA3.7.4.3 to confirm il is rale,d b HV! to com I with the airflow rates and sound requirements ass ecified in Section 5 and 7.2 of ASHRAE 62.2. Pool and Spa Systems and Equipment Measures: § 110.4(a): § 110.4(b)1: § 110.4~)2: § 110.4(b)3: § 110.5: § 150.0(p): Certification by Manufacturers. Afly pool or spa heating system or equipment must be certffied to have al! of the following: a thermal efficiency that con:p!ies wilh the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the ttiem10stat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heatin : Piping, Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return Jines. or built-in or buill-u connections to allow for future solar heatin Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time witch that will allow all um s to be set or pro rammed to run onJ durin off-eak electric demsnd eriods. Pilot Light. Natural gas pool and spa heaters mus! not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residenlfal pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves." Lighting Measures: § 110.9: § 150.0(!c)1A: § 150.0(k)1Bc § 150.0(k)1C: § 150.0(k)1D: . § ·,so.G~)1E: § 150.0(k)1F: § 150.0(k)1G: § 150.0(k)1 H: § 150.0(k)1 I: § 150.0(k)2A: § 150.0(k)28: § 150.0~)2C: § 150.0(k)ZD: § 150.0(k)2E: § 150.0(k)2F: Lighting Controls and Components. All lighting control devices and systems, ballasts, and Juminaires must meet the applicable requirements of§ 110.9." Luminaire-Efficacy. All installed luminaires must meet the requirements in Table 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device must be no greater t1an !he number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Down light Luminaires in Ceilings. Luminaires recessed in1o ceilings m0st meet ali of the requirements for: insulation contact (JC) labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150J [k)1C Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps-rated 13 watts or greater must be electronic and must have an ----~!l~L!\..~~~l:Y_Ql?J!o:1>~.!~<1!1 _2_Q.!<ttz:,.____ . _____ . ___ _.. ·---·--------_ _ ·-. -·· Night Lights, Srep Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 IU111ens. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kttchen eKhaust hoods) must meet the a olicable re uirements of 150.0 .k .- Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joinr Appendix JAB.· Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources :hat are not compliant with the JAB elevated temperature requirements, i:1eluding marking requirements, must not be installed in endosed or recessed luminaires. Light Sources in Drawers, Cabinets, and Linen Closets. light so1;rces internal to drawers, cabinetry or linen closets are no! required to comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no _ more_ th~n 150 lumens.'.. and ar~ equipped with_controls that automaticaUv tum ~e lighting_ _o~ when the drawer, cabinet or lifl€n closet is closed. Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7 A. Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems." Interior Switches and Controls. Lighting must have readily accessible wall..mounted controls that allow the lighting to be manually turned ON and OFF.' Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. Interior Switches and Controls_ Controls must not bypass a dimmer, occupant sensor, or vacancy sensor it.mcfon if the control is installed to com I wtth 150.0 k}. Interior Switches and Controls. Lighting controls must comply with the applicable requirements of§ 110.9. DYNAMIC ENERGY TITLE 24 CONSUL TING JENNIFER DESKIN CERTIFIED ENERGY ANALYST #R-13-17-10171 (760) 427-1507 1752 COTTENWOOD DRIVE. VISTA, CA. 92081 JENDESKIN@A TT.NET CERTlflCATE OF COMPLIANCE Project Name: Pavaghadi Calculation Description: ?avaghadi calculation Date/rime: 202l:-0S-17Tll:02;02-07:00 Input File Name: Pavaghadi.ribd19 CF1R,PR.F-01E (Page7 of 7) DOCUMENTATION AUTHOR'S OEClAAATION SfATEMENT 1. I certify thatthi~Certificate of Compliance documenta:ion is accurate ~nd comp let~. Documerrt:a:,oe A"1:horName; Jennifer Deskin Oocument:ltien Author Signa<11re: Company; :Signature □ate: ,-r;,, f.Dcycaacrn_,,_,_"'_c_g;_Ti_tt_,_2•---------------------+ocs_1,_,c/c20c2-1=~~~~~~~~~----1.c· A--------.JB,E:: C;::. C L._ C Addre,;.s; CEA/ HERS CectrftCatlon lderitific:itio..~ (H appiic:ible), 1752 Cottonwood Dr. CEA R13-17-10171 c,,-1,m,,,,.,;,,.,,,~o,,&cioa .. ,~~_,.,c,.,~,,1.;o" CE"RTIFll:'D EN:eRGYANALY$T City/Srate/2f;,: Phone· Vista, CA 92081 [760) 427-1507 RES?ONSIBtE PERSON'S DECLARATION STATEMENT I cert;f;" the foiiw,i-,,g Llnd~c p<l"nalty of _o~,j~,y, under th~ law~ of the State o· Califomio, I ~m cligbk, under Dh,ision 3 o( the flL·eane½ and p,::,f~!'ilrnis code to ~:«ept re,ponsibolily !or thi•ti..'Hdi~g desien identifl~d on this Cert,:licate of Compliance 2. f certify thatths-ener;ffoatures and perfurina~ce specifimtioris ldMti!led or. ,his certit1cil:eofC0~1j.,1;0nce conform 101he requirements ofT7tle-14, P.1n;1 Md Pnrt5oftheUll!ornia Code of Regulations. The buikl,ng Cesign features _er ,vst~m de,ign feature, identified on this cen;ifc.a1e o: Con:ipilanc:e,~-•~ion3islent with the information proviCeci on otiler applicable complianct' doruments. wcrksheets, calru/at1Ms, ;,lar,s and •~clrication~ subm1W.d to the ecrlcrcemen: osency fo< approv.l wih th,s bullding permit appl1cat,on RespOnsible o.,;,gner i'iame· Matthew Deskin Company: Deskin Building Design Address: Responsible Desi~n•r Signatura, /vi oi;t;the;w V0.lk-i-rt, Date Sisi'ledc 05/17/2021 4106 Sierra Morena Avenue City/Stale/Zip; carlsbad, CA 925010 Phone: (760)427-1505 /;Ji[M~11Y s.'9,ie,j 1,y_C,,nSo! lionl&EnerpJ" ff/{hii,r,,:yP..J/m_// Sys:"'r t.i,•,c,:s. /rrc. •CHE"..RS;. n,1, dig//,,r:,,;nstu,s 1spr,,.;,,,,,: in o,d.,. to'''"'"'~ the ,xwoo/ ,;,t m,s ,eg,s.a,M <'COIJ/~&~/. snd 1a M "'"Y ;m;,1,~s My,S:tsr,o,· Pr_ov,'Oc,, ,,,-,,,,~11,r;-W !M ,,ww•=r of /lie intwma/10,,. Rl?iaislration Numbi?r: 421-P010071121A-OOO-OOO.OOOGO[Kl.COOO Re~1stration Date/TLme: 05117,'202118:00 HERS Provider: CHEERS NDnCE,-'/'his -U').Qn! ha,"""">"·'"''"~" i,y CM&i Hcm~En&r,j f'f,.Je.,.-..,, ;JaMpo'ys-SNY_.,,,,..,, lr.c. (CHElYIS) 0-.sUlf} /r,(a,m~lh.1 uploat!M: /Jy 1/Jirti p;,rt,es ,ral ,i//'d/;alM Mlt cc ·el~te.d 0, Cf/ffflS ,.,,~,~,= Cl'ffRS ;$ noi r,,,<tJcns,,.•~ rec an(! ot1->~et r,v.,,,rnrc,e_ IM ,c.:i,rac;· "' cam~w•= .-t :.•~ "'''''"'•"'"" cnnu,tnctJ In ,n:,; tM'l,MN CASuilding Energy Efficiency Standards -2019 Re:sident!ai r,::rn~liance Report Ver,lQ!l: 2019.1.:-00 Report Generated: 2021-05-17 lS:02:47 Schema Version, rev 20200!,01 § 150,0(k)2G: § 150.0(k)2H: § 150.0(k)21: § 150.0ik)2J: § 150.0~)2K. § 150.0~)3A § 150.0(k)3B § 150.0(k)3C: § 150.0(k)4 § 150.0(k)5 § 150.0~)6A § 150.0(k)SB 2019 Low-Rise Residential Mandatory Measures Summary Interior SWitches and Controls. A!7 energy management control system (EMGS) may be used to comply with control requirements if it: provides functionality of the :;;pecified contra! according to§ 110.9; meets the !ns1allation Certificate requirements of§ 130.4: meets the EMCS requirements clJ_.'!_30.0(e): and meets all other requirements in§ 15_0_.0~l~kl~2~. ~---~~~-----~~~----• Interior Switches and Controls. A multi scene programmable controller may be used lo comply with dimmer requirements in § 150.0{k) if it rovides the functiona!i of a dimmer accordin to 110.9, and com lies with all other a II~ble uirements in 150.0 k 2. Interior Switches and Controls. In bathrooms, ga:rages, laundry rooms, and u!Uity rooms, at least one luminaire in each of these spaces must be controlled by an occupant sensor or a vacancy sensor providing automatic-offfunctiona!ily. If an occupant sensor is installed, it must be initially configured to manual-on operation using the manua! control required under Secfion 150.0{k)2C. Interior Switches and Controls. Lumir.aires that are or contain lighl sources that meet Reference Joint Appendix JAB requirements for dlmmin , and that are not com rolled b occu anc or vacanc sensors, must have dim min controls: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling-insta[led lighting systems. Residential Outdoor Lighting, For singi~family resideniial buildings, outdoor :ighting permanently mounted to a residential building, or to other buildings or. the same lot, must meet the requirement in item§ 150.0(k}3Ai (ON and OFF switch) and the requirements in either 150.0 k 3Aii hotocell and eilher a motion sense; or automatic time switch control or 150.0 k 3Aiii astronomical time clock , or an EMCS. Residential Outdoor Lighting. For low-rise residential buildings wiih four or more dwelling units, outdoor lighting for private patios, entrances, balconies, and porches: and residential parking lots and carports with iess than eight vehicles per stte must comply with ellher § 150.0(kJ3A or with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. For low-rise residential buildings wrth four or more dwslling units, any outdoor lighting fur resider:tial parking lots or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by§ 150.0(k)38 or§ 150.0(k)3D must comply with t~e applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Internally illuminated address signs. lnternally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined accordin to 130.0 c) Residential Garages for Eight or More Vehrcles. Lighting for residential parking garages for eight or more vehicles mest comply wrth tlie a !icable uirements fornonresiden6al ara es in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a !ow-rise multifamily residential building where 1he total interior common area in a single building equals 20 percent or less of the floor area, perrr.anenlly installed lighting for the interior common areas in that bui!din must be ron I with Table 150.0-A and be controlled an occu ant sensor. Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior com mm area in a single building equals more than 20 percent of the floor area, pennanently 'installed lighting for the interior common a:reas in that building must: i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Ligh!lng installed in cor'.1dors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at lea6l SO percent Theoccupar:,t sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Resick!nces, Single family residences lac led in subdivisions with 10 or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which do not have a photovoltaic s stem installed. must com I with the r uirements of 110.10 b throu h 110, 10 e . § 110.10(a)2: § 110.10(b)1: §110.10(b)2: § 110.10(b)3A: § 110.10(b)3B: § 110.10(bj4: § 110.10(c): § 110.10(d): § 110.10(e)1: § 110.10(e)2: Low-rise Multifamily Buildings. Low-rise multi-family buildings that do nothcve a photovoltaic system installed must comply wrth the requirements of§ 110, iO(b) through § 11D.10(d). Minimum Solar Zone. Area. The solar zone must have a minimum total area as d€sc:ibed below. Tne solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in nue 24, Part 9 or ether parts ofTitle 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less tharr 80 square feet each for buildings with roof areas less than or equal to 10,000 square feel or no Jess than 160 square feet each for buildings with roof areas greater than 10,000 square feet For single famHy residences, the solar zone must be localed on the roof or overhang of the building and have a total area no less than 250 square feet For low-rise mulh-family buildings the solar zone must be located on !he roof or overhang of the building, or on the roof or overhang of another st'Ucture located within 250 feel of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any sky(ight area. The solar zone requirement is applicable to the entire buildi , including mixed occupanc .· Azimuth. All sections of the solar zone located on steep-sloped roofs must be oriented between 90 degrees and 300 degrees of true north. Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, arid roof mounted e uipment.· Shading. Ar.y obstruction located on the roof or any other part of the building that projects above a solar zone must be located al least twice the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest int of the solar zone. measured in lhe vertical lane." Structural Design Loads □n Construction Documents. For areas of the roof designated as a solar zone, !he structural design loads for roof dead load and roof live load must be clearl indicated on the cor,Struction documents. Interconnection Pathways. 1 he constructton documerrts must indicate: a location reserved for inverters and metering equipment and a palhway reserved for routing of conduit from the solar zone to the point of interconnection with the electricaf service; and for single family residences and central water-heatin s stems, a thwa reserved for routin olumbin from the solar zone to the water-healin tern. Documentation. A copy of the construction documents or a comparable document indicating the information from§ 110.10(b) through § 110.1_Q_(c) rnu~~-~.2£!1Yi.c!~l9..!ti~ o~-~~~- Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel, The main electricaJ servlce panel must have a reserved space to allow for the installalion of a double pole c'rrcuit breaker for a future solar electric installation. The reserv-ed space must be permanently marked as "For Future Solar Electric". REVISIONS (!) z -C ..J -:J m zz -(!) ~ -U) U) WW cc :J C <C I w (!) ~ <C (!) I -::c w > -0:::: 0 0 0 ~ z 0 ..-co 0 N 0) I-<( ts o () -Ni LO 0 LO ..- I l'- N 'V ----0 co I'- '-" LO (J) . t---I ..-> a. co T""" I ("') N 0~ 0 LO ("') LO 0 I 0 0 LO T""" DRAWN CHECKED DATE SCALE SHEET T24 1, I ;... ru (Nl \./ALL TD PLANE \./ITH EXISTING CD FTG, MINIMUM 4 INCH THICK SLAB 4' THICK \./ITH #3 BAR AT 18' D/C, EACH \,/ AY AT MID-H□GHT □VER 2' SAND FILL \,// 10 MILL V!SQUEEN M□ISTURE BARRIER DYER 2' SAND FILL. I_ I ' I 1_ -J. -- I (E) FTG, .. ------------- ---."-!al'-~ 8' STEM\.IALL • 0 _, "" - • "' I - L=40'-0' w ....I ....I <IC :,, "' w '"" " • a, ----, ----,/<'-I+-.;------14'-l'" 1------------if''-------11'-10' --------------14'-1' ------.;-,fl-,/~ !SLOPE ._ ____________ _ &"~ I ~.~ MINIMUM 4 INCH THICK SLAB 4' THICK \./ITH #3 BAR AT 18' D/C, EACH \,/ AY AT MID-HEIGHT OVER 2' SAND FILL \,// 10 MILL VISQUEEN M□ISTURE BARRIER DYER 2' SAND FILL. • "' I ;,., !SLOPE 8' STEM\./ ALL --'--,,..,,~ i-----lOOA SUB-PANEL \./ITH 30'x36' \.IDRKSPACE -------------------------~ ~ ~i@ S~l ,.lf-'--,1,•~ 1 '-10' -if'------------------------40'-0' -------------------------Z- I F □UNDA TI □N PLAN i SCALE 1/4'=1'-0' 1, _, " ru SYMBOLS LEGEND DETAIL NUMBER DETAIL SHEET NUMBER = FOOTING W&'&'&'&'$ff$= NOTE, PROVIDE BOLT PATTERN FDR 2x6 EXTERI□R \./ALLS \./HERE NOTED, PROVIDE B□L TING FOR 3X PLATE (IF APPi )CABLE) ----------REBAR CHANGE IN ELEVA TIDN 0----HOLDDOWN SCHEDULE MARK TYPE BOLT CAPACITY ICC_ER CL 37 MST37 -2465 <{ 48 MST48 3695 2105 a:: - 1--C') 60 MST60 -4665 2 HDU2 %"¢ ROD 3075 z 4 HDU4 %"¢ ROD 4565 2330 3: 5 HDU5 %"¢ ROD 5645 0 0 0 8 HDQ8 ¾"¢ ROD 7630 --' 0 I 11 HHDQ11 1 "¢ ROD 11810 2330 14 HHDQ14 1 ,!¢ ROD 13015 NOTES· (1) -ROD -ASTM1554 Gr 36 THREADED ROD WITH EMBEDDED DOUBLE NUT AND WASHER. V:'J SHEARWALL SCHEDULE EDGE/ SILL PLATE -op PLATE SEISMIC WIND MARK ALLOW ALLOW BOUNDAR NAILING A.B. NAIL SDS LTP4 3/8" CDX (THREE PLY) G 260 365 8d @ 6" 54" 6" -30" H 380 532 8d @ 4" 42" -6" 20· 15/32" CDX (FIVE PLY) L 310 435 42" -6" 24" 10d @ 6" L2 620 870 24" -6" 12" M 460 645 36" -a· 16" 10d @ 4" M2 920 1290 18" -4• 8" N 600 840 30" -6" 12" 10d @ 3" N2 1200 1 l:i80 15" -3" 6" p 770 1077 20" -4" 1 o" 1 Od @ 2" P2 1540 2155 1 O" -2" 5" PAD SCHEDULE ~ 3'-6' SQ, x 18' DEEP vi/ (5) 114 BARS EA, v/AY ~ 2' -,,• SQ, x 18' DEEP vi/ (3) 114 BARS EA, vi AY FOUNDATION NOTES 1, CONCRETE FDR F□□TINGS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS AND SHALL BE COMPOSED OF 1 PART CEMENT, 3 PARTS SAND, 4 PARTS 1 INCH MAXIMUM SIZE ROCK, AND NOT MORE THAN 7-1/2 GALLONS OF \,/ATER PER SACK OF CEMENT. UNLESS □THERl,/ISE NOTED. 2, HORIZONTAL DISTANCE FROM BOTTOM LEADING EDGE OF FOOTING TO DAYLIGHT SHALL BE 7'-0' MINIMUM DR AS RECOMMENDED BY SOILS REPORT. 3, F□UNDA TI□N PLATES OR SILLS SHALL BE B□L TED TD THE FOUNDATI□N 1,/ITH , <CBC 2308.6 AND 2308,12,8)< o) b) c) d) e) MINIMUM 1/2" DIAMETER HQT DIPPED GALVANIZED STEEL BDL TSJ MINIMUM 5/8' DIAMETER H□T DIPPED GAi YANIZFP STEEL B[]L TS IN BUILDINGS LOCATED IN SEISMIC DESIGN CATEGORY EJ AT LEAST 7' EMBEDMENT INT□ CONCRETE □R MASONRY AND NOT MORE THAN 6'-0' SPACINGJ MINIMUM Tl,/0 BDL TS PER PIECE 1,/ITH ONE BDL T LOCATED N1JT MORE THAN 12' OR LESS THAN 4' FROM EACH END OF EACH PIECE1 HOT DIPPED GAi YANTZED STEEL PLATE \JASHERS A MINIMUM OF 3.,x3"x0.229' USED ON EACH B□LTJ THE HOLE OF THE PLATE \,/ASHER IS PERMITTED TD BE DIAGONALLY SLOTTED 1,/ITH A \.IIDTH OF UP TD 3/16' LARGER THAN THE B□L T DIAMETER AND A SLOT LENGTH NOT TD EXCEED 1-3/4', PROVIDED A STANDARD CUT \,/ASHER IS PLACED BETl,/EEN THE PLATE \,/ASHER AND THE NUT, 4, SILLS AND SLEEPeRS ON A CONCRETE SLAB IN DIRECT CONTACT 1,/ITH EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREAT[D \./ODD, (CBC 2304,11.2,4) 5, VERIFY L□CA TI□NS OF ALL ITEMS TD BE IN, UNDER, THROUGH DR EMBEDDED IN THE CONCRETE PRIOR TD FOUNDATION INSPECTION, 6, ALL H□LDOl,/N ANCHORS TD BE 'SIMPSON' 7. llEtN~□LDOl,/NS, B□L TS ETC. TD BE SECURELY TIED IN PLACE PRI□R TD FOUNDATION INSPECTION, 8. ALL H□LDDl,/NS AND POST ANCHORS ARE TO BE HOT DIPPED GALVANIZED AND INSTALLED ACCORDING TD SIMPSON STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC. REPORT, U.O.N, 9. MINIMUM CONCRETE 1,/IDTH OF STEMl,/ALLS SHALL BE 8 INCHES FDR RECEIVING H□LDDl,/NS U,O.N, VERIFY L□CATI□NS OF H□LDOl,/NS AND ANCHOR BOLTS 1,/ITH FRAMING PLAN TD ASSURE PROPER AND ACCURATE INST ALLA TI□N, 10, UFFER BAR -PROVIDE A #4 BAR MIN, 20 FEET CONTINUOUS, LOCATED AT BOTTOM OF FOOTING MIN. 3 INCHES ABOVE GRADE AND PROTRUDING 12 INCHES ABIJVE SLAB OR STEM \,/ALL FOR ELECTRICAL GROUND, LOCATl□N SHALL BE VERIFIED BY THE ELECTRICAL CONTRACTOR, IF APPLICABLE. 11. PROVIDE 1,/EAKENED PLANE/EXPANSION JOINTS IN ALL SLABS. <16'-0' □.C. MAX,) SEE DETAIL, 12, 1,/00D POSTS EXPOSED TD 1,/EATHER DR 1,/EATHER SPLASH SHALL BE 1' ABOVE A SLAB DR 8' ABOVE GRADE (CBC 2304,11,2,7), 13, SH□\./ a• CLEARANCE Off ADJACENT GRADE FOR \,/ODD FRAMING/SHEATHING RESTING □N EXTERIOR FOUNDATl□N 1,/ALLS/F□OTINGS:, (CBC 2304,11,2,2), 14. SH□\,/ 8 INCH MiillMUM \,/ODD TD EARTH SEPARATION OR PROVIDE PRESERVATIVE-TREATED \,/DOD. <CBC 2304Jl.2,2), 15, 1,/AITING PERl□D FDR CONCRETE SLABS □N GRAUE PRIOR TO START OF CONSTRUCTION SHALL BE AS FOLLDl,/S< NO \,/ORK OF ANY KIND SHALL BE PERFORMED REF□RE CONCRETE HAS ACHIEVED 70 PERCENT OF DESIGNED STRENGTH. REVISIONS w C) > z 0::: 0 -C 0 ..J 0 LO -0 ,...... 0 =>· s co LO 0 ,...... al z N I om~ zz I-. -.;t <( -C) I-(.) .-, ~-0 0 u, u, (_) <(~ WW NI-._. LO Cl) . cc r---I ,...... > a.. DRAWN CHECKED DATE SCALE SHEET 3 • 0 I ,_ ru • "' I 0 - • w I (') • w I ~ I (E) BARN I I (N) STORAGE I CONG STOOP 127. f SL□PE ...J "' ~ LANDING • 0 t+-+-+-UP J (") J I' # 10' STEPS =:;;2~----14'-1' -----+-----,,~-----11'-10' -------¥---------14'-l' ------- i ll============='lc===:izt:============i~======+========1 2'xB' METAL DOOR 10' xB' SECTI□NAL DR • 0 I (') - @/4@ 1'-10' --,I'---,/~ I (N) GARAGE I !SLOPE lO'xS'SECTIONAL DR 4 5 NOTE• ALL RECEPTACLE OUTLET LOCATIONS SHALL COMPLY \JITH CEC ARTICLE 210,52, f;i,,w)¼¾ 10' x8' SECTI□NAL DR --,!'-----10'-0' -----ii~ -~----10'-0' ----~-3'-2' ...J "' ru .... Tu OUTDOOR COMPRESSOR FDR ELECTRIC DUCTLESS MINI-SPLIT HEAT PUMP/AIR C□NDITI□NER BY MITSUBISHI. MODEL• MUZ-MH DR APP. EQIV. BTU HEAT RATING, 24,000 BTU/HR, PROVIDE CLEARANCES AS REQUIRED, • "' _, . 0 I ;:... ru i-----!OOA SUB-PANEL WITH 30'x36' WORKSPACE (") - -~-----------------------40'-0' ------------------------,if- GARAGE FLOOR PLAN SCALE 1/ 4'=1'-0' (N) UPPER FLOOR ADU (N) A TT ACHED GARAGE (N) AlTACHED STORAGE 908 SQFT 1080 SQFT 36.66 SQFT GARAGE DOOR OPENERS SHALLHAVE BATTERY BACK-UP. (SB 969), FLOOR PLAN NOTES 1. NEW \JINDO'JS SHALL BE DUAL GLAZED. 2, TYPICAL EXTERIOR WALL ASSEMBLY. A. WOOD HORIZONTAL \JOOD SIDING □VER (2)-LAYER GRADE 'D' PAPER □VER SHEAR PANEL (MATCH EXISTING). B. GYPSUM WALLBOARD <TYP 'X' \JHERE REQUIRED), C, 2x6 EXTERIOR WALL FRAMING WITH INSULATION (PER TITLE-24 CALCS). 3, 2x10 CEILING JOISTS AT 16' 0/C, 4. EXPOSED \JDDD POST, 5. EXPOSED HEADER BEAM. 6, C□NC LANDINGS AND PA nos MINIMUM 48' AND EXTENDING 6' BEYOND EACH SIDE OF OPENING, 7. SURFACE MOUNTED GAS TANKLESS WATER HEATER BY N□RITZ, MODEL NRC711 PROPANE GAS. REFER TD TITLE 24 FDR ADDITIONAL REQUIREMENTS. PROVIDE 120 VOLT RECEPTACLE ACCESSIBLE 'wlTHIN 3 FEET Of 'wATER HEATER, 8, OUTDOOR COMPRESSOR FDR ELECTRIC DUCTLESS MINI-SPLIT HEAT PUMP/AIR CONDITIONER BY MITSUBISHI. MODEL• MUZ-MH DR APP, EQIV, BTU HEAT RATING, 24,000 BTU/HR, PROVIDE CLEARANCES AS REQUIRED. ST AIR'w' A Y DESIGN REQUIREMENTS (CRC R311, 7), STAIR WIDTH• MINIMUM WIDTH OF 36'. HEADROOM, MINIMUM HEADROOM OF 6'-8', filSE!. BET\JEEN 4' AND 7.75'. Rllli!. MINIMUM RUN □F 10', <FDR \JINDING STAIRS• 6' MINIMUM TREAD DEPTH AT NARRD\JEST P□INT AND 10' MINIMUM TREAD DEPTH AT 12' INSIDE OF RADIUS. (CRC Rll.7.5,2.D TREAD NDSINGS BETWEEN 0.75' AND 1.25' ON STAIR\/ AYS WITH SOLID RISERS, <WHEN TREADS ARE LESS THAN 11'), WIDTH, STAIR\JAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL P□INTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELO\J THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4,5 INCHES □N EITHER SIDE OF STAIRWAY. (CRC R311,7,D. □PEN RISERS ARE PERMITTED PROVIDED THAT THE OPENING BET\JEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4-INCH SPHERE, <CRC R3U,7.5,l), THE GREATEST RISER HEIGHT \JJTHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH, THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH, GUARDS (CRC R312), SHALL BE PROVIDED FDR THOSE PORTIONS OF □PEN-SIDED WALKING SURFACES THAT ARE LOCATED MORE THAN 30-INCHES ABOVE THE FLOOR DR GRADE BELOW. SHALL HAVE A HEIGHT OF 42-INCHES. (MAY BE 34-INCHES ALONG THE SIDES OF STAIRS) .. OPENINGS BETWEEN THE RAILINGS SHALL BE LESS THAN 4-INCHES. THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND BOTTOM ELEMENT OF GUARDRAIL AT A STAIR SHALL BE LESS THAN 6-INCHES. SHALL BE DETAILED TO SHOW CAPABILITY TO RESIST A CONCENTRATED LOAD OF 200-P□UNDS IN ANY DIRECTION ALONG THE TOP RAil AND 50 PSF FDR INFILL COMPONENTS, HANDRAILS (CRC R:311,7.8), SHALL BE PROVIDED ON AT LEAST □NE SIDE OF EACH STAIR\JAY WITH 4 DR MORE RISERS. HANDRAILS AND EXTENSIONS SHALL BE 34' TD 38' ABOVE NOSING OF TREADS AND BE CONTINUOUS. THE HANDGRIP P[□RTI□N OF ALL HANDRAILS SHALL BE NOT LESS THAN 1-1/4 INCHES NOR MOR THAN 2 INCHES IN CROSS SECTIONAL DIMENSION. HANDRAILS ADJACENT TO WALLS SHALL HAVE AT LEAST 1-1/2 INCHES BETWEEN THE \JAL,L AND THE HANDRAIL. ENDS □F HANDRAILS SHALL BE RETURNED OR SHALL HAVE ROUNDED TERMINATI□NS DR BENDS. REVISIONS (!) z -C ...J -:J al zz -(!) ~-en en WW cc :J C <( I w (!) ~ <( (!) I - w > o:'. 0 0 0 LO 0 ..-0 s co LO 0 ..--z N I 0 O') I'-- N I-. v I-<( ..-0 0 0 0 -<O <( I'-- NI-._, LO CJ) . t---I ..-> a. DRAWN CHECKED DATE SCALE SHEET 4 ----·--------- w z -...J w f- <C ...J a_ • -I i'o w z -...J w f- <C ...J a_ • -I 0' • ,,.,.,. " I " • 0 I "' • 00 I 0 - A SDI E SDI <TYP) <TYP) 3'-7' +--6'-0' I 3'-2 • ru ' -I .,. I - ~ -'k-----"1.-----',.___-----+----!W~ ,J r • I j r' • ,.. ' "' I .,. I ~ ' ' ' @' A SDI <TYP) 3'-7' -----¥---6'-0' __j_ II ST AIR\./ A y FTG. PLAN SCALE 1/ 4'=1'-0' +E--- 7± I , = M SDI A SD2 TI -~~-,Do, l I , l ---------lJ_ _ __fj ___ _lL _ ____r--~, _-;-'", ---~~, :'rd==~d..--~ GRADE ------'-------------'-------------'-----'---------"'-GRADE ha\v'~E~S~T~<~S~I=D~E~)~E=L=E~V~A~T~I=□~ SCALE l/ 4'=1'-0' • .-«\J ("') . . ' I' I' • 0 I "' ' ,, • ru '--I --I • "' 00 -(J'\ I C, - • ~ " I -ru ' ' ' ' • • ,,.,,.. ,,.,,.. " " I I " " ' ' ' ' ' ' • ~ ,.. I '° ' ' ~---9'-7" -------¥-- i,_ 3'-7' I, 6'-01 ' ---, (M\ , , --,'L-3'-2 --, L. \21:;,/ ru -.,. DN 2x6 'TREX' DECKING \./ITH (2)-3' COATED 4x!2 DECK SCRE\./S EACH DECK J□ISTS, • ru '--I .,. I -,I ~ ,I ~ LEDA -1) L 3'-0' -, (Nl 1--f' - IN\ ( <Nl 3° x68 ~ DOOR /M\ ~ 6'-0' __j_ <-3'-7' ' 7 , ft SDI -'4xl0 HDR 4xl2 STGR 4x!O HDR• - I QC "' I 0 -X ,.. ' "' "' f- V) ru -X .,. - "' "' I 0 -;1 Ax!O HDI I I ' ' ), L "' -"' I 0 -X .,. 4x!O HDR 4x12 STGR , 2x8 DECK JOIST ' AT 16' 0/C, , - SDI ~I lo\ -I ru ~ -X .,. "' "' I I '° X '° -' ' ' ' ' -I ' ' 4x8 HDR ' ' @'-· ' -@ \ A w L _____ --------- ~, ~: D:~_:_ -----------, I I I I I I ( \ IZI IZI ) 1M Tl "" II ST AIR\./ A y PLAN SCALE 1/ 4'=1'-0' J-Z --------------[;J ~) REF IGIJI: D~~ -:------------, I I I ( \ IZI IZI I' ) II ST AIR\./ A y FRAMING SCALE 1/ 4'=1'-0" f--"' I I I I ~ I \ ' ' ' ' I I, - ( j - C]] \ (0) -' ' ' ' ' ' I I I I I I I I I I ' I I I I ' ~ "' I I I ' I \ I I ' I I ' - ( j C]] \ (0) - I I I I I ' ' I ' ' ' I ' I I I ' ' ' ' ' REVISIONS C) z -C ...J -:::::, m zz -C) ~-U) U) WW cc w > -0::: 0 0 0 I.() 0 ..-0 > CX) I.() > 0 ..-ZN 1 om~ I-<( "st I-,. ... ..--.. 0 '-' 0 () <( ~ NI-.__. I.() Cl) . r-,...-I ..-> a.. DRAWN CHECKED DATE SCALE SHEET Al FRAMING NOTES I. ALL FRAMING SHALL BE IN ACCORDANCE 'w'ITH 2019 CRC; CONVENTIONAL LIGHT FRAME CONSTRUCTION AND ALL OTHER APPLICABLE SECTIONS □F THE BUILDING CODE, 2, ROOFING SHALL BE CLASS A FIRE RATED MATERIALS, 3, FIELD MEASURE AND VERIFY FRAMING FDR DETERMINING TRUSS SPANS AND LAYOUT PRIOR TD ORDERING TRUSSES, INST ALL ALL TRUSSES TD MFR'S SPECS. 4. 5, 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. MINIMUM TOP PLATE SPLICE TD BE 48' LAP 'w'ITH (8) 16cl LAP SPLICE NAILING. CALIFORNIA FILL: PL Y'w'DDD SHALL BE CONTINUOUS UNDER CALIFORNIA FILL. PROVIDE 2x SOLID BLOCKING ALONG TRUSS RIDGE LINES DR PER MFR'S SPECS. 'w'HERE TOP DR SOLE PLATES ARE CUT FDR PIPES, A METAL TIE MIN. 0.054 INCHES THICK AND 1-1/2 INCHES 'w'IDE SHALL BE FASTENED ACROSS THE OPENING 'w'ITH (8)-10cl NAILS EACH SIDE. THE STRAPS SHALL NOT EXTEND LESS THAN 6' BEYOND THE CUT OR NOTCH. (CRC R602.6.D. DIAPHRAGM SHEATHING NAILS OR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SO THAT THEIR HEAD OR CR □'w'N IS FLUSH 'w'ITH THE SURFACE OF THE SHEA THING, MAINTAIN 1/2 INCH CLEARANCE BET'w'EEN TRUSSES AND NON-BEARING VALLS, PROVIDE SIMPSON STC TRUSS CLIP 'w'HERE BOTTOM CHORD OF TRUSS IS PERPENDICULAR TD INTERIOR NON-BEARING 'w'ALL, DO NOT CUT, DRILL, NOTCH, BORE, SHAVE, TAPER DR FOR ANY REASON MODIFY PRE-ENGINEERED/MANUFACTURED STRUCTURAL ELEMENTS SUCH AS GLU MEMBERS, PARALLAMS, MICROLLAMS, I-JOISTS, LIGHT GAUGE METAL MEMBERS, AND OTHER SIMILAR TIMBER OR STEEL PRODUCTS UNLESS SUCH MODIFICATIONS ARE 'w'ITHIN THE 'w'RITTEN PARAMETERS SET FORTH BY THE LISTED MANUFACTURER OF THAT PRODUCT OR BY A SIGNED AND STAMPED DETAIL BY THE PROJECT ENGINEER OF RECORD, IN ALL □PEN BEAM CONSTRUCTION PROVIDE SIMPSON LSTA30 STRAP-TIE OVER RIDGE TO RAFTERS, FOR 2x CONSTRUCTION USE SIMPSON LSTA24 AT EACH RAFTER OVER RIDGE, IF APPLICABLE ALL TRUSSES SHALL BE LEGIBLY BRANDED, MARKED OR OTHER'w'ISE HAVE PERMANENTLY AFFIXED THERETO, THE FOLLD'w'ING INFORMATION LOCATED 'w'ITHIN T'w'O FEET OF THE CENTER □F THE SPAN ON THE FACE □F THE BOTTOM CHORD: <IF APPLICABLE) o.,) IDENTITY OF THE MANUFACTURING CO. □F THE TRUSS, b.) THE DESIGN LOAD AND AND THE SPACING OF THE TRUSSES. TRUSS HANGERS SHALL BE SIMPSON THA29 TYP. AT EACH TRUSS HANGING FROM GIRDER TRUSSES OR PER MANUFACTURERS SPECS, U.O.N, (IF APPLICABLE). BALLOON FRAME ALL 'w'ALLS 'w'ITH SLOPING CEILINGS, MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED 2x4 -3x4 -2x6 STUD 'w'ALLS AT 16' D/C, IS 10'-0' FOR BEARING 'w'ALLS. MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED NON-BEARING 2x4 AND 3x4 STUD 'w'ALLS AT 16' 0/C. IS 14'-0', -2X6 'w'ALLS IS 20'-0'. FASTENERS FDR PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED 'w'□OD SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE DR COPPER. <CRC R317.3.D. PROVIDE DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS, ALL TRUSS DR JOIST CONNECTIONS (TRUSS TD TRUSS, TRUSS TD GIRDER, TRUSS PLY. TO TRUSS PLY, AND FIELD SPLICES) SHALL BE DESIGNED BY THE TRUSS MANUFACTURER <CRC R502.11.4). DIAPHRAGM BOUNDARY ~-DIAPHRAGM BOUNDARY NAILING ,-----,.------L+~::::)-.-~---~~ MIN. PL Y\v'OOD _ ___, DIMENSION SHALL ROOF DR FLOOR JOIST BE 24' UNBLOCKED AND 12' AT BLOCKED DIAPHRAGMS. EDGE NAILING 4x8 PL Y'w'□□D 'w'ITH FACE GRAIN PERPENDICULAR TD FRAMING. BOUNDARY NAIL AT CONTINUOUS PANEL EDGES AT BLOCKED DIAPHRAGM <IF APPLICABLE). TYP ROOF OR FLOOR DIAPHRAGM I (E) BARN I @Hue HANGER REPLACE (D RIM J□IST \/ITH 6x10 GIRT PER DETAILW ~ WHUC HANGER ~ 8'-111 PLATE LINE 9'-1' PLATE LINE e ~~ II~ ...J "' A I ... X '° II 11 II II II II II 't (; 1.25' LSL STAIR STRINGERS 4x BLOCKING \IITH CMST 14 FULLY NAILED 6x12 HDR A , 6xl2 HDR 18'-0.25' PLATE LINE @, __ , ' LINE OF OVERHANG ABOVE ~.f9 I 9'-1" PLATE LINE 't (; I baaa M-"=A~I~N"--=F=R=-A=-M=I~N=G=P=L~A~Ndlll SCALE 1/4'=1'-0' 6x12 HDR ------------------------- 9'-111 ~------1 PLATE LINE SYMBOLS LEGEND L=12"-0' w POST DR TRIMMER AS NOTED SHEAR PANEL MEMBER, MINIMUM LENGTH NOTED. SEE ENG, CALCS. <J----0-t> SPAN AND DIRECTION OF ROOF MEMBER PER SCHEDULE. 1-----0----(> SPAN AND DIRECTION OF FLOOR MEMBER PER SCHEDULE. BEARING \./ALL CAL-FILL AREA. NOTE: CAL -FILL AREA. PROVIDE □NE BAY 'w'IDTH X 30' ACCESS AND VENTILATION OPENING, PROVIDE 2X BLOCKING AND EDGE NAILING OF ROOF SHEATHING AROUND OPENING. FRAMING SCHEDULE ~ <l---0--v 2x10 CEILING JOISTS. AT 16' 0/C, 2x6 ROOF RAFTERS. AT 24' 0/C. FLOOR SHEATHING CAL-FILL ALLDVABLE SPANS 2x4 R.R. AT 24' 0/C, 6' -0' MAX SPAN 2x6 R.R. AT 24' 0/C, 10'-0' MAX SPAN 2x8 R.R, AT 24' 0/C. 12'-10' MAX SPAN 2x10 R.R. AT 24' 0/C, 15'-8' MAX SPAN 2x12 R,R. AT 24' 0/C, 18' -3' MAX SPAN 2x14 R.R. AT 24' D/C, 20'-5' MAX SPAN MINIMUM 3/4' T~G UNDERLAYMENT DR □SB EQUIVALENT 'w'ITH #lOcl RING-SHANK NAILS 6' 0/C. EDGES AND BOUNDARIES, 10' □IC. FIELD. USE ARCHITECTURAL GLUE PER MANUFACTURER'S SPECS. EXTERIOR 'vi ALL SHEA THING ALL EXTERIOR \./ALLS SHALL BE SHEAR PANELED UNLESS □THER'w'ISE NOTED 'w'ITH 3/8' CDX PL Y'w'□□D \./ITH #Bel NAILS 6' 0/C, AT EDGES AND BOUNDARIES, AND 12' 0/C, FIELD. °'07 SHEARWALL SCHEDULE EDGE/ SILL PLATE -op PLATE SEISMIC WIND MARK ALLOW ALLOW BOUNDARY NAILING A.B. NAIL sos LTP4 3/8" APA RATED SHEATHING G 260 365 8d @ 6" 54" 6" -30" H 380 532 8d @ 4" 42" -12" 20" 15/32" APA RATED SHEATHING L 310 435 42" 6" -24" 10d @ 6" L2 620 870 24" -6" 12" M 460 645 36" -8" 16" 10d @ 4" M2 920 1290 18" -4" 8" N 600 840 30" -6" 12" 1 Od @ 3" N2 1200 1680 15" -3" 6" p 770 1077 20· -4" 1 o" 1 Od @ 2" P2 1540 2155 1 o" -2" 5" NOTES: (1) -VALUES NOTED ARE MAXIMUM SPACINGS. CONNECTORS SHALL BE AS FOLLOWS: A. 'BOLT' -%"ill F1554-36 ANCHOR SOLT EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR MASONRY. PROVIDE 1-½" EDGE DISTANCE AT ANCHOR BOLTS. 8. 'NAIL' -16D COMMON NAIL. C. ·sos· -SIMPSON sos ¼-"X4.5" WOOD SCREW (ICC ESR-2236). SCREWS SHALL BE STAGGERED WHEN SPACING IS 2.5" OR LESS. (2) -SILL AND BOUNDARY MEMBERS FOR WALLS WITH A SEISMIC CAPACITY OF 350PLF OR GREATER SHALL BE 3X NOMINAL LUMBER OR LARGER. PROVIDE ½" MINIMUM OGE DISTANCE FOR NAILING OF THESE MEMBERS. (3) -ANCHORS SHALL BE INSTALLED WITH 3"X3"X0.229" MINIMUM PLATE WASHERS. (4) -L2, M2, P2, ETC. DENOTES SHEATHING TO BOTH SIDES OF SHEAR WALL. (5) -FIELD NAILING SIZE SHALL MATCH THE EDGE NAILING AND BE SPACED @ 12" OC. ----------------------------------- (!) z -C ..J -:::> cc REVISIONS zz 52 S2 en en WW cc DRAWN CHECKED DATE SCALE SHEET 6 FRAMING NOTES 1. ALL FRAMING SHALL BE IN ACCORDANCE \./ITH 2019 CRC, CONVENTIONAL LIGHT FRAME CONSTRUCTION AND ALL OTHER APPLICABLE SECTIONS OF THE BUILDING CODE. 2. ROOFING SHALL BE CLASS A FIRE RATED MATERIALS. 3. FIELD MEASURE AND VERIFY FRAMING FOR DETERMINING TRUSS SPANS AND LAYOUT PRIOR TD ORDERING TRUSSES, INSTALL ALL TRUSSES TD MFR'S SPECS. 4. MINIMUM TOP PLATE SPLICE TD BE 48' LAP \./ITH (8) 16cl LAP SPLICE NAILING. 5. CALIFORNIA FILL, PL Y\./DDD SHALL BE CONTINUOUS UNDER CALIFORNIA FILL. 6. PROVIDE 2x SOLID BLOCKING ALONG TRUSS RIDGE LINES DR PER MFR'S SPECS. 7. \./HERE TOP DR SOLE PLATES ARE CUT FDR PIPES, A METAL TIE MIN. 0.054 INCHES THICK AND 1-1/2 INCHES \./IDE SHALL BE FASTENED ACROSS THE OPENING \./ITH (8)-!0cl NAILS EACH SIDE. THE STRAPS SHALL NOT EXTEND LESS THAN 6' BEYOND THE CUT DR NOTCH. (CRC R602.6.D. 8. DIAPHRAGM SHEATHING NAILS DR OTHER APPROVED SHEATHING CONNECTORS SHALL BE DRIVEN SD THAT THEIR HEAD DR CRD\./N IS FLUSH \./ITH THE SURFACE OF THE SHEA THING. 9. MAINTAIN 1/2 INCH CLEARANCE BET\./EEN TRUSSES AND NON-BEARING \./ALLS. PROVIDE SIMPSON STC TRUSS CLIP \./HERE BOTTOM CHORD OF TRUSS IS PERPENDICULAR TD INTERIOR NON-BEARING \./ALL. 10. DD NOT CUT, DRILL, NOTCH, BORE, SHAVE, TAPER DR FDR ANY REASON MODIFY PRE-ENGINEERED/MANUFACTURED STRUCTURAL ELEMENTS SUCH AS GLU MEMBERS, PARALLAMS, MICROLLAMS, I-JOISTS, LIGHT GAUGE METAL MEMBERS, AND OTHER SIMILAR TIMBER DR STEEL PRODUCTS UNLESS SUCH MODIFICATIONS ARE \./ITHIN THE \./RITTEN PARAMETERS SET FORTH BY THE LISTED MANUFACTURER OF THAT PRODUCT DR BY A SIGNED AND STAMPED DETAIL BY THE PROJECT ENGINEER OF RECORD. 11. IN ALL OPEN BEAM CONSTRUCTION PROVIDE SIMPSON LSTA30 STRAP-TIE □VER RIDGE TD RAFTERS. FDR 2x CONSTRUCTION USE SIMPSON LSTA24 AT EACH RAFTER □VER RIDGE. 12. 13. 14. 15. 16. 17. IF APPLICABLE ALL TRUSSES SHALL BE LEGIBLY BRANDED, MARKED OR DTHER\./ISE HAVE PERMANEt--lTL Y AFFIXED THERETO, THE FDLLD\./ING INFORMATION. LOCATED \./!THIN T'w'□ FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD, <IF APPLICABLE) o.,) IDENTITY OF THE MANUFACTURING CO. OF THE TRUSS. b.) THE DESIGN LOAD AND AND THE SPACING OF THE TRUSSES. TRUSS HANGERS SHALL BE SIMPSON THA29 TYP. AT EACH TRUSS HANGING FROM GIRDER TRUSSES DR PER MANUFACTURERS SPECS. U.□.N. <IF APPLICABLE). BALLOON FRAME ALL \./ ALLS \./ITH SLOPING CEILINGS. MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED 2x4 -3x4 -2x6 STUD \./ALLS AT 16' D/C. IS 10'-0' FDR BEARING \./ ALLS. MAXIMUM UNBRACED HEIGHT OF LATERALLY UNSUPPORTED NON-BEARING 2x4 AND 3x4 STUD \./ALLS AT 16' D/C, IS 14'-0', -2X6 \./ALLS IS 20'-0', FASTENERS FOR PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED \./ODD SHALL BE HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE DR COPPER. <CRC R317.3.D. PROVIDE DOUBLE FLOOR JOISTS UNDER ALL PARALLEL PARTITIONS. ALL TRUSS DR JOIST CONNECTIONS (TRUSS TD TRUSS, TRUSS TO GIRDER, TRUSS PLY. TO TRUSS PLY, AND FIELD SPLICES) SHALL BE DESIGNED BY THE TRUSS MANUFACTURER <CRC R502.11.4). DIAPHRAGM BOUNDARY ~-DIAPHRAGM BOUNDARY NAILING EDGE NAILING 4x8 PLY\./DDD \./ITH FACE GRAIN PERPENDICULAR TD FRAMING, BOUNDARY NAIL ROOF DR FLOOR JOIST AT CONTINUOUS PANEL EDGES AT BLOCKED DIAPHRAGM <IF APPLICABLE). TYP R □□F DR FLOOR DIAPHRAGM A • 0 I -L=40'-0' • 0 ' -.------------l---">i.-----1-----~GI-------------------~---- A,__ _ _, 1'-0" "' ~ -' "' A 6x HDR --------, 6xl2 RIDGE BM PROVIDE 4x4 K.P. AT EACH END OF RIDGE. A 1 ' DI\./ I I r --l----- I I I • 0 J - K SD! 6x6 HDR "' A :,: ... X ... ~ :,: ... X ... 6x6 HDR 6x12 RIDGE BM SIMPSON 4x10 'U' HANGER EACH SIDE 11aaall R"""=D'==D==F~F:=aaR.aa.A.aa.MaaaaaJ~N"""G~P,=L"=='A"=='N~II SCALE 1/ 4 '=1' -0' oi oi "' A :,: ..,. X ... 4x4 HDR w "' "' X A ... -"' 6x HDR PROVIDE 4x4 K.P. AT EACH END OF RIDGE. SYMBOLS LEGEND L=ll:'-0' w <J---0--t> ~ POST DR TRIMMER AS NOTED SHEAR PANEL MEMBER, MINIMUM LENGTH NOTED. SEE ENG. CALCS. SPAN AND DIRECTION OF ROOF MEMBER PER SCHEDULE. SPAN AND DIRECTION OF FLOOR MEMBER PER SCHEDULE. BEARING \./ ALL CAL -FILL AREA, CAL-FILL ALLDIJABLE SPANS 2x4 R.R. AT 24' 0/C. 6'-0' MAX SPAN 2x6 R.R. AT 24' 0/C, 10'-0' MAX SPAN NOTE• CAL -FILL AREA. PROVIDE □NE BAY \,/IDTH X 30' ACCESS AND VENTIL.A TIDN OPENING. PROVIDE 2X BLOCKING AND EDGE NAILING OF ROOF SHEATHING AROUND OPENING. 2x8 R.R. AT 24' 0/C, 12'-10' MAX SPAN 2x10 R.R. AT 24' D/C, 15'-8' MAX SPAN 2x12 R.R. AT 24' D/C. 18'-3' MAX SPAN FRAMING SCHEDULE 2x14 R.R. AT 24' D/C, 20'-5' MAX SPAN <J----0---t> CONVENTIONALLY FRAMED ROOF 2x10 ROOF RAFTERS AT 24' D/C, <l-/4>--C> CONVENTIONALLY FRAMED DORMER 2x6 ROOF RAFTERS AT 24' D/C, 0 2x8 FASCIA (MATCH EXISTING). [I] 2x6 FASCIA (MATCH EXISTING). ROOF SHEA THING 15/32' CDX PL Y\,/DOD SHEATHING PANEL INDEX 32/16, DR 15/32' □SB STRUCT 1 \./ITH #Sci NAILS 6' D/C, AT EDGES AND BOUNDARIES, AND 12' D/C. FIELD. EXTERIOR \./ALL SHEATHING ROOF ALL EXTERIOR \./ALLS SHALL BE SHEAR PANELED UNLESS □THER\,/ISE NOTED \./ITH 3/8' CDX PLY\,/ODD \./ITH #Sci NAILS 6' D/C. AT EDGES AND BOUNDARIES, AND 12' 0/C. FIELD . ~ SHEARWALL SCHEDULE EDGE/ SILL PLATE -op PLATE "1ARK 3EISMICI WIND ALLOW ALLOW BOUNDARY NAILING A.B. NAIL SDS LTP4 3/8" APA RATED SHEATHING G 260 365 8d @ 6" 54" 6" -30" H 380 532 8d @ 4" 42" -12" 20" 15/32" APA RATED SHEATHING L 310 435 42" 6" -24" 1 Od @ 6" L2 620 870 24" -6" 12" M 460 645 36" -8" 16" 1 Od @ 4" M2 920 1290 18" -4" 8" N 600 840 30" -6" 12" 1 Od @ 3" N2 1200 1680 15" -3" 6" p 770 1077 20" -4" 1 o" 1 Od @ 2" P2 1540 2155 1 o" -2" 5" NOTES: (1) -VALUES NOTED ARE MAXIMUM SPACINGS. CONNECTORS SHALL BE AS FOLLOWS: A. 'BOLT' -%"¢ F1554-36 ANCHOR BOLT EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR 1-!ASONRY. PROVIDE 1-½" EDGE DISTANCE AT ANCHOR BOLTS. B. 'NAIL' -16D COMMON NAIL. C. 'sos' -SiMPSON sos ¼"X4.5" WOOD SCREW (ICC ESR-2236). SCREWS SHALL BE STAGGERED WHEN SPACING IS 2.5" OR LESS. (2) -SILL AND BOUNDARY MEMBERS FOR WALLS WITH A SEISMIC CAPACITY OF 350PLF OR GREATER SHALL BE 3X NOMINAL LUMBER OR LARGER. PROVIDE ½" MINIMUM DGE DISTANCE FOR NAILING OF THESE MEMBERS. (3) -ANCHORS SHALL BE INSTALLED WITH 3"X3"X0.229" MINIMUM PLATE WASHERS. (4) -L2, M2, P2, ETC. DENOTES SHEATHING TO BOTH SIDES OF SHEAR WALL. (5) -FIELD NAILING SIZE SHALL MATCH THE EDGE NAILING AND BE SPACED @ 12" OC. REVISIONS w (!) > z 0:::: 0 -C 0 ..J 0 LO -0 ..--0 ::, s co LO m 0 ..--z N I QO'>~ zz I-. -.:;t -(!) I-(3 --~ -0 0 en en 0 <(~ WW NI-._ LO Cf) . cc r---I ..--> Cl.. DRAWN CHECKED DATE SCALE SHEET 7 CONVENTIONALLY FRAMED R□□F ASSEMBLY WITH 2x6 R□□F RAFTERS AT 24' D/C. 15/32' CDX PL YW□□D SHEATHING WITH #Sci NAILS 6' D/C, AT EDGES AND BOUNDARIES, AND 12' D/C, FIELD, U.□.N. CLASS 'A' C□MP□SITI□N SHINGLES □VER 40# FELT MANUFACTURER• GAF PRODUCT• 'TIMBERLINE' ICC APPROVAL• ESR-1475 :... 2D f---H I (0 7 GRADE"------ll II SECTION C□NC STOOP 4 GRADE SCALE 1/4'=1'-0' R-30C 'CATHEDRAL CLG.' -~ BATT INSUL AT CLG. PAPER FACED NOT PERMITTED A SD2 R----R-21 BATT INSUL AT WALLS fa ------i 11 GRADE----- , ' I LIVING I ' ' , 9 BED #1 11 I GARAGE I R-21 BATT INSUL AT WALLS '"' l'.l I w >--<C ...J 0.. • -I (0 ATTIC AREA CONVENTIONALLY FRAMED R□□F ASSEMBLY WITH 2xl0 R□□F RAFTERS AT 24' D/C. 15/32' CDX PL YWO□D SHEATHING \,/ITH #Bel NAILS 6' 0/C, AT EDGES AND BOUNDARIES, AND 12' D/C, FIELD. U.O.N. CLASS 'A' C□MP□SITl□N SHINGLES □VER 40# FELT MANUFACTURER• GAF PRODUCT• 'TIMBERLINE' ICC APPROVAL• ESR-1475 R-30 BATT INSUL AT CLG, PAPER FACED NOT PERMITTED R-~--R-21 BATT INSUL AT \,/ALLS BATH R-19 MINIMUM BATT INSUL AT FLOOR, 111-------< 7 i------GRADE SECTION KEYNOTES I. TYPICAL SLOPED R□□F ASSEMBLY A, ROOFING MATERIAL (PER ROOF PLAN), 2. TYPICAL EXTERI □R WALL ASSEMBLY, A. \,/ODD HORIZONTAL W□□D SIDING □VER (2)-LAYER GRADE 'D' PAPER □VER SHEAR PANEL (MATCH EXISTING). B. GYPSUM 1,/ALLBOARD <TYP 'X' WHERE REQUIRED), C. 2x6 EXTERI□R WALL FRAMING D, 2x4 EXTERI□R WALL FRAMlNG 3. 2x10 CEILING JOISTS AT 16' □IC. 4. EXPOSED W□□D POST. 5. EXPOSED HEADER BEAM. 6. C□NC LANDINGS AND PATIOS MINIMUM 48' AND EXTENDING 6' BEYOND EACH SIDE □F OPENING, 7. C□NC SLAB• 4' NOMINAL \,/ITH #3 BARS AT 18' EACH WAY AT MID-HEIGHT. OVER 2' SAND FILL \,/ITH 6 MILL VISQUEEN VAPOR BARRIER □VER 2' SAND FILL 8, 2x8 SPRUCE FASCIA. WATERPROOF TD GUTTER. 9, 15/32' CDX PL Y\,/DDD SHEATHING PANEL INDEX 32/16, DR 15/32' □SB STRUCT 1 WITH #Bel NAILS 6' D/C, AT EDGES AND BOUNDARIES, AND 12' D/C, FIELD, 10. 2x6 SPRUCE FAS CIA. 11. PROVIDE 5/8' TYPE 'X' GYPSUM BOARD AT WALLS AND CEILINGS \,/ITH HABITABLE ROOMS ABOVE FDR FL□DR/CEILING FIRE SEP·ARATI□N. !lliECTION (1) SCALE 1/4'=1'-0' CONVENTI□NALL Y FRAMED ---... ROOF ASSEMBLY WITH 2x10 R□□F RAFTERS AT 24' 0/C, 15/32' CDX PL YWO□D SHEATHING WITH #Bel NAILS 6' D/C, AT EDGES AND BOUNDARIES, AND 12' 0/C, FIELD, U,O,N, CLASS 'A' COMPOSITION SHINGLES OVER 40# FELT MANUFACTURER• GAF PRODUCT• 'TIMBERLINE' ICC APPROVAL• ESR-1475 B.N. ~ ' 112 ATTIC AREA jobbdOOQ R-21 BATT INSUl AT WALLS I CLOSET I OJ □ BED #2 , ' 2A 1------1 2CI---~ .------<11 R-19 MINIMUM BATT INSUL AT FLOOR. I GARAGE I 11 II SECTION (3] SCALE 1/4'=1'-0' R-30C 'CATHEDRAL CLG.' BATT INSUL AT CLG. PAPER FACED NOT PERMITTED --Z-------¥--1' -0 .. DRIVE C□NVENTl□NALL Y FRAMED -~ ROOF ASSEMBLY \,/ITH 2x10 ROOF RAFTERS AT 24' 0/C, 15/32' CDX PLYWOOD SHEATHING \,/ITH #Bel NAILS 6' D/C, AT EDGES AND BOUNDARIES, AND 12' D/C, FIELD. U.□.N. CLASS 'A' C□MP□SITI□N SHINGLES □VER 40# FELT MANUFACTURER• GAF PRODUCT, "TIMBERLINE' ICC APPROVAL• ESR-1475 R-30C 'CATHEDRAL CLG.' BATT INSUL AT CLG. PAPER FACED NOT PERMITTED B.N. R-21 BATT INSUL AT WALLS 2Al------l 2c1------ GRADE-------1 i-------t 11 '"' l'.l I w >--<C ...J 0.. • -I a, 7 12 7± fa 9 B.N. ~ 2 LINE □F~ ',,,, HABITABL SPACE R ' '---- I LIVING I 2x10 CEILING JOISTS AT 16' D/C, GARAGE~ SD2 , I i I \ , • 'i' ;:... 11 1-~-hlhl'-1·-0· 1------'GRADE II SECTION (2) SCALE 1/ 4'=1'-0' REVISIONS C) z -C ...J -=> al zz -C) ~ -C/J C/J WW cc =>· C <( I w C) <( a::: <( C) co 'T"'"" I ('I') N o';J O LO ('I') LO 0 'T"'"" I 0 0:: 0 LO W --co ~ ~ I'-::, -z DRAWN CHECKED DATE SCALE SHEET 8 ----------- C□NVENTIONALL Y FRAMEJJ -~--.._ ROOF ASSEMBLY w'ITH 2xi0 ROOF RAFTERS AT 24' □IC. 15/32' CDX PL Yw'□□D SHEA THING w'ITH -~ #Bd NAILS 6' El/C, AT EDGES AND BOUNDARIES, AND 12' 0/C, FIELD, U.□.N. CLASS • A' C□MPOSITION - SHINGLES □VER 40# FEL, MANUFACTURER, GAF PRODUCT• 'TIMBERLINE' rec APPROVAL, ESR-1475 +E--- 7± I ATTIC AREA 2x8 AT 24' □IC. R-21 BATT INSUL AT VALLS 2CI-----+ 11 , I STAIR'w'AY I r----~~----l 11 B.N, 2x8 AT 24' 0/C, □ ,-: ~ l!l d R-30C 'CATHEDRAL CLG.' BA TT INSUL AT CLG. PAPER FACED N□T PERMITTED 0 □ • 0 I a, j LIVING I R-19 MINIMUM BA TT INSUL AT FL□□R. -(4)-1.25' LSL STAIR STRINGERS (REINFORCE w'lTH C□NTJNU□US 2x8), I GARAGE I GRADE------1•L_,,,=========================,_J•1-----GRADE II SECTION (s)I scALE 114•=1·-o· --------- 1, 2. 3. 4, 5. 6. 7. 8. 9. 10. 11. SECTION KEYNOTES TYPICAL SL□PED R□DF ASSEMBLY A. R□□FING MATERIAL (PER R□□F PLAN). TYPICAL EXTERIDR VALL ASSEMBLY. A. w'□OD HORIZONTAL w'O□D SIDING □VER (2)-LAYER GRADE 'D' PAPER OVER SHEAR PANEL <MATCH EXISTING). B. GYPSUM w'ALLBOARD (TYP 'X' \,'HERE REQUIRED), C. 2x6 EXTERIDR w'ALL FRAMING D. 2x4 EXTERIOR w'ALL FRAMING 2x10 CEILING JOISTS AT 16' 0/C, EXPOSED w'OOD POST. EXPOSED HEADER BEAM. C□NC LANDINGS AND PA TI□S MINIMUM 48' AND EXTENDING 6' BEYOND EACH SIDE □F OPENING. C□NC SLAB• 4' NOMINAL w'lTH #3 BARS AT 18' EACH w'AY AT MID-HEIGHT, □VER 2' SAND FILL w'ITH 6 MILL VISQUEEN VAPOR BARRIER OVER 2' SAND FILL 2x8 SPRUCE FASCIA, w'ATERPR□□F TO GUTTER. 15/32' CDX PLYw'□□D SHEATHING PANEL INDEX 32/16, OR 15/32' □SB STRUCT 1 w'ITH #8d NAILS 6' □IC. AT EDGES AND BOUNDARIES, AND 12' 0/C, FIELD. 2x6 SPRUCE FAS CIA. PROVIDE 5/8' TYPE 'X' GYPSUM BOARD AT w'ALLS AND CEILINGS w'ITH HABITABLE ROOMS ABOVE FOR FLOOR/CEILING FIRE SEPARA Tl□N, (!) z -C ..J -::> al z -~ en w C ::> C <C I w (!) ~ <C (!) I REVISIONS w > -a::: 0 0 0 LO 0 ...---0 s CO LO 0 ...---z N I om "-z N I-. 'Q" (!) I-<( --oOo -0 ~ CD en <( "-w NI-,.__, LO (/) . C "--I ...---> a.. DRAWN CHECKED DATE SCALE SHEET 9 • • • • • • • • • I I I I I I I I I I I ; I I I I I ! I I I I I I I I I I I I I I I I I I I 11 11 I I ' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I +E--- 7± I I I I I I I I I I I I I I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I • • • • • • • • • • • • • ' ~~,H w (E) BARN z -_j ~~ -~---w .... .., _j / / / AND OVERHANGS 0.. • SLOPED DR FLAT. -I (X) 3A IC w z -_j w .... .., _j 0.. • -I (X) "-:::.--rr • ' "' • ' 'I I I I I l I I I I I I I I I I I I I I I I I I I I I I ! I --------1 lC "' w z -_j w .... .., _j 0.. • -I "' +--GRADE :i:a GRADE l'-1 ;:... (\J ----------,--·---------- -IB ' ' ' ORTH (REAR) ELEVATION SCALE 1/ 4'=1'-0' IC I----+ 1'-0' -;<-----.1'1.....------------+--rl ,-: A 0 ~ EAST (SIDE) ~ I ±7 T I-'---\. SDI /-----------1 w z -_j w .... .., _j 0.. ' -I (X) w z -_j w .... .., _j 0.. ' -I er, --4-GRADE ELEVATION II SCALE 1/ 4'=1'-0' --------------------------------------------- I w . , - ~ ~ ===========------~ -_ -_ -_---=:;;;;~~~~==2:i===jf D j O 0 4A 7 "' f------_, ____ ..__,_,__---jJ □ GRADE+----\J=========""\,a=======+====fl.lb=aaJllJ~&-_.1 _ __, GRADE <D BARN D □ 0 4A II \JEST (SIDE) ELEVATION I 3B SCALE 1/4'=1'-0' CLASS •A• C□MP□SITIDN SHINGLES OVER 40# FELT MANUFACTURER• GAF PRODUCT• 'TIMBERLINE" ICC APPROVAL• ESR-1475 4D II SOUTH (FRONT) ELEVATION SCALE 1/4'=1'-0' ELEVA TI □N NOTES I. EXTERIIR F'INISH !A, ROOFING MATERIAL, SEE R□□F PLAN, !B, ll□□D SIDING TD MATCH EXISTING S.F.D. □VER C2) LAYERS TYPE 'D' FELT PAPER, IC, Ix AND 2x PLANT -□NS, 1/IND□II TRIM SURROUNDS AND CORNERS, 2. 2A. 2B, 3. IJ[I]]) \IDDD CORBEL (BY □IINER) .. 2x8 FASCIA, USE 2-#16 GAL V, NAILS PER R□□F RAFTER. METAL 3A. G,I. FLASHING AT INTERSECTION. 3B. SECTIONAL METAL GARAGE DOORS. 4. SPECIAL.TY 4A. C□NC LANDINGS AND PATIOS• MINIMUM 48" AND EXTENDING 6" BEYOND EACH SIDE □F OPENING. 4B. 100A SUB-PANEL. 4C. EXTERIOR LIGHT FIXTURE. BY □IINER. 4D, 2x6 DORMER FASCIA, USE 2-#16 GAL V. NAILS PER R□□F RAFTER, GRADE REVISIONS w (!) > z a:: 0 -C 0 ..J 0 LO -0 ..--0 :::, s co LO 0 ..--ca ZN' om~ zz I-. s:;t I-<( ---(!) oOo ~ -() -(0 <( r--en en WW NI-._ LO Cl) . r---I cc ..--> CL co ...- I ('I') N :::, 0 ~ C O LO A' ('I') LO """" 0 ...-I I w 8 o:: (!) LOW <( -. CD 0::: ~~ <( I'-::::, (!) ---z I C0 _J :i: w 8 w C N () <( ~ 0) 0:: (!) 0:: . <( A'Q<(O,_ """" () U) > <( -o:: <(ZOO Q. ::::, <( 0::: (9 CD (I) :::, <( (/) (/) >-...J...JW A ~ 0:: (/) """" N <( (/) :E (0 () <( DRAWN CHECKED DATE SCALE SHEET 10 B. G.I. METAL DORMER VENT ATTIC VENTILA TI □N CALCULA TI □NS ALL NE',{ R□DfING SHALL BE CLASS 'A' FIRE RATED AREA 1-ATTIC SPACE CALCULATIONS• NOTE• THE GENERAL CONTRACTOR SHALL VERIFY THE NET FREE VENTILA TIDN OF THE VENT. PRODUCT SELECTJDN AGAINST THOSE ABOVE MUST MAINTAIN REQUIRED VENTILATION, ATTIC AREA 1120.00 SQ.FT. RATIO OF VENTILATION REQUIRED X 1/300 SQ, IN. C□NVERSI□N I□ SQUARE INCHES X 144 SQ .IN. TOTAL AREA OF VENTILATION REQUIRED I 537.60 SQ. IN. ,. LOI,/ VENTILATION (LOCATED AT DR NEAR EAVE LIND. 50¼-60¼ MINIMUM REQUIRED = 26B 80 SQ.IN. A. TAPEREn LO\J PROFILE VENT <4> USED = 72 SQ.IN. EA BY □'HAGIN \JITH 1/4' CORROSION RESISTANT TOTAL 1296 SQ.IN. METAL MESH. AREA OF L.mL, VENTILATION PROVIDED 288 SQ, IN, >< UPPER VENTILATION <LDCATEn NO MORE THAN 3-FEET BELD\J RIDGE LIND. 50¼-401/. MINIMUM REQUIRED = 268.80 SQ.IN. B. G.I. METAL DORMER VENT \JITH 1/ 4' CORROSION RESIST ANT METAL MESH. AREA OF UPPER VENTILATION PROVIDED A 1------J (3) USED = 100 SQ.IN. EA TOT AL 300 SQ.IN. 300 SQ, IN, • 0 I :... · · · ·RIDGE · . · 12;12. A PROVIDE INSULATION STOP SUCH THAT INSULATION DOES NOT OBSTRUCT FREE AIR MOVEMENT AS REQUIRED BY THE BUILDING OFFICIAL. ALL OVERLAP FRAMED ROOF AREAS SHALL HAVE AN OPENING BET\JEEN THE ADJACENT ATTICS IN THE ROOF SHEATHING (AS ALLD\JED BY THE STRUCTURAL ENGINEER, IF APP.) TD ALLD\J AIR PASSAGE AND ATTIC VENTILATION BET\JEEN THE T\JO DR ELSE ISOLATED SPACES SHALL BE VENTED INDEPENDENTLY. PER CBC. ...... · ·□oo.· .... . =-=· A, TAPERED LO\J PROFILE VENT BY □'HAGIN \JITH 1/4' CORROSION RESISTANT METAL MESH. ·v······· . . . ... . . . . .. . . ' . . ' ... . \JITH 1/4' CORROSION RESISTANT METAL MESH, ·o···· . . . . -. . ' ' -_. _·... -. _· .. -. 1'-0' -JL-,IL ·w·. L'.l . c,· -·· . O!· . . 8' · .... ·. . {\j (\J◊· ..... ·. . -···-. . . . . ·ru -ru .. . . . . ...-i .. ·...:-i . -. . ' . . . . -. . . . . . . . . -' . B A .. ···v····· . . . . . . ru . . . -. ,...-,1. . . (\J . . . . . --... . . . . . . . .. . . . . . . . ... ···o··.·.·· ciJ · ... . ..,-I, ' • . (\J .. -. . . . . . ' . . . -...... . II ROOF PLAN ~ SCALE 1/4'=1'-0' ,__ _ _., A ....... h.l .. ·er· . "A',. .. -· . . . . -{)! ··◊· .·.:.·.:.9··.·· . (\J,.(U . -· . -.. (U .. (U . ,..;..i· ........ . . . . . . . ' . . . .......... ' .. B NOTE, ATTIC VENTILATION OPENINGS SHALL BE COVEREn \JITH CORROSION RESISTANT METAL MESH \JITH 1/16 MINIMUM TO 1/4' MAXIMUM □PENINGS. (CRC R806,D. ROOF PLAN NOTES 12' EAVE OVERHANG, TYPICAL U.□.N. 12' GABLE OVERHANG, TYPICAL U.□.N. 1. TYPICAL SLOPED ROOF ASSEMBLY• A. CLASS 'A' COMPOSITION SHINGLES □VER 40# FELT MANUFACTURER• GAF PRODUCT• 'TIMBERLINE' ICC APPROVAL: ESR-1475 <MATCH EXISTING) . B, BUILDING FELT PER ROOFING MANUF, C, PL Y\./DDD SHEATHING PER FRAMING PLAN, 0 2x8 FASCIA <MATCH EXISTING). m 2x6 FASCIA (MATCH EXISTING), 2, G.I. METAL RAIN GUTTERS AT EAVES (OPTIONAL) 3. TYPICAL DD\./NSP □UT -VERIFY LOCATION. 4. LINE OF STRUCTURE BELO\./, I[ =D.S. 5, R □□F COVERING, ALL R□□F COVERING SHALL BE INSTALLED PER APPLICABLE REQUIREMENTS □F CBC 1507. ROOF COVERINGS SHALL BE AT LEAST CLASS A RATED IN ACCORDANCE \./ITH ASTM E 108 DR UL 790, \./HICH SHALL INCLUDE COVERINGS □F SLATE, CLAY DR CONCRETE R□□F TILE, EXPOSED CONCRETE R □□F DECK, FERROUS DR COPPER SHINGLES DR SHEETS, (COUNTY BUILDING CODE 92.1.1505.D 6, R □□F FLASHING, FLASHING SHALL BE INSTALLED AT \./ ALL AND R□□F INTERSECTIONS, AT GUTTERS, \./HEREVER THERE IS A CHANGE IN ROOF SLOPE DR DIRECTION, AND AROUND R□□F OPENINGS, \./HERE FLASHING IS □F METAL, THE METAL SHALL BE CORROSION-RESISTANT \./ITH A THICKNESS □F NOT LESS THAN 0.019 INCH <NO, 26 GALVANIZED SHEET), (CRC R903,2,D 7, \./ATER RESISTIVE BARRIER AT VERTICAL SURFACES, A MINIMUM □F □NE LAYER □F ND, 15 ASPHALT FELT SHALL BE ATTACHED TD STUDS DR SHEATHING □F ALL EXTERIOR \./ALLS, SUCH FELT DR MATERIAL SHALL BE APPLIED H□RIZ□NTALL Y, \./ITH THE UPPER LAYER LAPPED □VER THE LD\./ER LAYER MINIMUM 2 INCHES. \./HERE JOINTS OCCUR, FELT SHALL BE LAPPED MINIMUM 6 INCHES. THE FELT SHALL BE CONTINUOUS TD THE TOP □F \./ALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TD MAINTAIN A \./EATHER-RESISTANT EXTERIOR \./ALL ENVELOPE. (CRC R703,2) REVISIONS w (!) > z 0:::: 0 -C 0 .J 0 LO -0 ..,-a :::::, s 00 LO 0 ..,... al ZN' QO>~ zz I-. ,;;t" -c, I-<( --oO o ~ -U) U) (.) <( f-2 WW N I-.__.. LO Cl} . cc r---I ..,... > a.. DRAWN CHECKED DATE SCALE SHEET 11 ELECTRICAL AND MECHANICAL INFDRMA TIDN 1. 2, 3. 4. 5. 6. 7. 8. 9. 10. 11, 12. 13. 14. 15. 16. 17, 18. 19. 20. 21, 22. 23, 24, 25. 26, 27, 28, 29, 30. 31. 32, 33, ALL PROJECTS SHALL COMPLY \/ITH THE 2019 CALIFORNIA BUILDING CODE AND/DR CALIFORNIA RESIDENTIAL CODE, 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA MECHANICAL CODE, 2013 CALIFORNIA PLUMBING CODE, 2019 CALIFORNIA FIRE CODE, 2019 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS, AND ALL COUNTY COUNTY □F SAN DIEGO AMENDMENTS. GFCI PROTECTED OUTLETS, FOR LOCATIONS DESCRIBED IN (NEC 210.B(A)• LAUNDRY AREAS, KITCHEN DISH\IASHERS, KITCHENS, GARAGES, BATHROOMS, OUTDOORS, \IITHIN 6-FEET □F A SINK, ETC, ARC-FAULT PROTECTION FDR ALL OUTLETS (N□T JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.12(A), KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC, LUMINAIRE REQUIREMENTS. INSTALLED LUMINARIES SHALL MEET THE EFFICACY AND FIXTURE REQUIREMENTS OF CBEES 150~(k) PROVIDE PERMANENTLY \/IRED, INTERCONNECTED SMOKE DETECTORS \/ITH BATTERY BACK-UP (SO THAT THE ACTIVATION □F □NE \/ILL ACTIVATE ALL □F THE OTHERS). IN THE D\IELLING UNDERGOING AN ADDITI□N, AL TERA TION □R REPAIR AT THE FOLLO\IING LOCATIONS (CBC 907,2.10,1,2)• a) w'ITHIN EACH SLEEPING ROOMJ b) OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMSJ c) AT EACH STORY \/!THIN THE D\IELLING UNIT INCLUDING BASEMENTS AND HABIT ABLE ATTICS. (BATTERY OPERATED SMOKE ALARMS MAY BE USED IN EXISTING AREAS □F BUILDING \/HERE \/HERE THE INST ALLA TJON □F SMOKE -ALARMS \IDULD REQUIRE THE REMOVAL □F INTERI□R FINISHES). SH□\/ PERMANENTLY \/IRED INTERCONNECTED CARBON MONOXIDE DETECTORS, HARD \/IRED \/ITH BATTERY BACK-UP FDR NE\/ CONSTRUCTION AT THE FOLLO\l!NG L□CA TIONS (CRC R315)• a) OUTSIDE EACH SLEEPING R□□MJ b) AT EACH STORY \/!THIN THE D\IELLING UNIT. BATTERY-OPERATED DETECTORS ARE ACCEPTABLE IN EXISTING AREAS \/ITH ND CONSTRUCTION TAKING PLACE AND IN AL TERA TI□NS N□T RE SUL TING IN REMOVAL OF INTERIOR \/ALL OR CEILING AND \IITH□UT ACCESS VIA AN ATTIC, CRA\IL SPACE, DR BASEMENT. (CRC R315.2) WATER HEATER SEISMIC STRAPPING. MINIMUM T\10 3/4-INCH-BY-24-GAUGE STRAPS REQUIRED AROUND \/ATER HEATERS, \/ITH 1/4-INCH-BY-3-INCH LAG BOLTS ATTACHED DIRECTLY TD FRAMING, STRAPS SHALL BE AT PEl!NTS \/!THIN UPPER THIRD AND LO\IER THIRD □F \/ATER HEATER VERTICAL DIMENSI□N, LO\IER CONNECTION SHALL OCCUR MINIMUM 4 INCHES ABOVE CONTROLS. (CPC 507.2), GAS APPLIANCES IN GARAGES. \/ATER HEATERS AND HEATING/CODLING EQUIPMENT CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE PLACED □N MINIMUM 18-INCH-HIGH PLATFORM UNLESS LISTING REPORT NUMBER PROVIDED SHO\IING IGNITION-RESISTANT APPLIANCE. CPC 507.13 AND CMC 308,1) IMPACT PROTECTION □F APPLIANCES. \/ATER HEATERS AND HEATING/COOLING EQUIPMENT SUBJECT TD VEHICULAR IMPACT SHALL BE PROTECTED BY BOLLARDS OR AN EQUIVALENT MEASURE. <CPC 507,13 AND CMC 308.1.D. WATER CLOSET Cl EARANCE, MINIMUM 30-INCH \/IDE BY 24-INCH DEEP CLEARANCE REQUIRED AT FRONT OF \I ATER CLOSETS, (CPC 402,5), \JATER CLOSET EFFICIENCY. ALL \/ATER CLOSETS SHALL USE MAXIMUM 1.28 GALLONS AVERAGE PER FLUSH, (CPC 403.2), SHOWER srzE. SHO\IER COMPARTMENTS SHALL HAVE MINIMUM AREA □F 1024 SQUARE INCHES AND BE ABLE TD ENCOMPASS A 30-INCH-DIAMETER CIRCLE. SHD\IER D□□RS SHALL HAVE A MINIMUM 22-INCH UNOBSTRUCTED \IIDTH. (CPC 408,5 AND CPC 408.6). FjREPI ACE APPLIANCES, FIREPLACES \/ITH GAS APPLIANCES ARE REQUIRED TD HAVE THE FLUE DAMPER PERMANENTLY FIXED IN THE □PEN PDSffiON AND FIREPLACES \/ITH LPG APPLIANCES ARE TD HAVE ND 'PIT' OR 'SUMP' CONFIGURATIONS, (CMC 303,7,1), CHIMNEY Cl EARANCE. MINIMUM 2-F□□T CHIMNEY CLEARANCE REQUIRED ABOVE BUILDING \/!THIN 10-F□□T HORIZ□NTALL Y □F CHIMNEY. THE CHIMNEY SHALL EXTEND MINIMUM 3 FEET ABOVE HIGHEST POINT \/HERE CHIMNEY PASSES THROUGH R□□F. (CRC RI003,9), TAMPER RESISTANT RECEPTACLES FDR ALL LOCATIONS DESCRIBED IN NEC 210 AND 406. a) TAMPER RESISTANT RECEPTACLES FDR ALL LOCATIONS DESCRIBED IN NEC 210,52 AND 550.13 (l.e ALL RECEPTACLES IN A D\IELLING). NOT USED, EXACT LOCATION OF ALL OUTLETS AND RECEPTACLES SHALL COMPLY \/ITH 2013 CEC AND SHALL BE VERIFIED BY 0\/NER, COORDINATE EXTERIOR LIGHTING AND PD\IER REQUIREMENTS \/ITH 0\/NER, VERIFY ALL METER LOCATION REQUIREMENTS \/ITH UTILITY CD, <IF APPLICABLE), DUCT SEALING AND LEAKAGE TESTING IS REQUIRED PER <CEC 150 (r,) 11 UNLESS NE\/ DUCTS ARE LESS THAN 40-FEET. CONTRACTOR TO BALANCE HVAC SYSTEM PER CFM REQUIREMENTS AFTER COMPLETING INST ALLA T!ON. NOTE• □PENABLE \IINDD\IS SHALL BE LOCATED A MINIMUM □F 10 FEET FROM ANY PLUMBING VENTS, CHIMNEYS. ETC. <CRC R303,5) GAS VENTS AND NON-COMBUSTIBLE PIPING IN \/ALLS PASSING THROUGH THREE \/ALLS DR LESS, SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR OR CEILING. PROVIDE A MINIMUM OF ONE 20 AMP LAUNDRY BRANCH CIRCUIT, SUCH CIRCUIT SHALL HAVE ND OTHER OUTLETS. <CEC210-ll<C)(2), DRYER VENTS SHALL C□MPL Y \/ITH <CMC 504.1.2) AND• a) MUST BE A MINIMUM OF 4 INCH DIAMETERJ b) SHALL BE A MAXIMUM OF 14-FOOT COMBINED HORIZONTAL AND VERTICAL LENGTH \/ITH T\10 90-DEGREE ELBD\ISJ c) SHALL HAVE T\10 FEET DEDUCTED FROM THE MAXIMUM LENGTH FOR EACH ELBO\I IN EXCESS OF T\ID, (CMC 504.11). EXEMPTION• PROVIDE MFR'S SPECS. ALLO\IING GREATER DUCT SPAN (SEE DETAIL I/SD3, FAil IN ATTIC, MIN. 30'x30' \IORK!NG SPACE AT SERVICE SIDE □F CONTROLS. CMC 904.10.3. <NOT REQUIRED IF FURNACE CAN BE SERVICED FROM ACCESS OPENING), THE CONTROL VALVES IN SHO\IERS, BATHTUBS, AND BIDETS MUST BE PRESSURE BALANCED DR THERM□ST A TIC MIXING VALVES. CPC SECTl□NS 408, 409, 410. PROVIDE LISTED NON-REMOVABLE TYPE BACK FLO\/ PREVENTION DEVICE AT ALL HOSE BIBBS. FIREPLACE GAS VALVES MUST BE LOCATED OUTSIDE OF REQUIRED HEARTH AREA, BUT ND MORE THAN 48 INCHES. A DEDICATED MINIMUM OF □NE-20 AMP CIRCUIT FDR BATHR□OM(S) OUTLET. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS, THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM. <CEC 210-ll<C) <3). A MINIMUM OF T\10 SEPARATE 20 AMP CIRCUITS SHALL BE PROVIDED TD THE KITCHEN APPLIANCES, THE T\10. OR MORE SMALL -APPLIANCE BRANCH CICUITS SHALL HAVE ND OTHER OUTLETS, (CEC 210,52b), BATHROOM EXHAUST FANS SHALL BE HUMIDITY CONTROLLED PER CMC CHAPTER 4 AND CALIFORNIA GREEN BUILDING STANDARDS CODE CHAPTER 4, DIVISION 4,5. KITCHEN DISH\IASHER BRANCH CIRCUIT• GFCl PROTECTl□N SHALL BE PROVIDED FDR OUTLETS THAT SUPPLY DISH\IASHERS INSTALLED 11>1 D\IELLING UNITS. <CEC 210,B<D). I (E) BARN I C□NC STOOP ENERGY EFFICIENCY REQUIREMENTS LUMINARIES• ALL LUMINARIES SHALL BE HIGH EFFICACY IN ACCORDANCE 'wITH ENERGY STANDARDS TABLE 150.0-A ALL LED LUMINARIES AND LAMPS SHALL BE MARKED 'JAB-2019' AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DATABASE. ALL RECESSED D □'wNLIGHT AND ENCLOSED LUMINARIES SHALL BE MARKED 'JAB-2019-E' AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DAT ABASE. LUMINARIES MUST HAVE A LABEL CERTIFIED FDR AIRTIGHT CONSTRUCTION, LIGHT SOURCES NOT MARKED 'JAB-2019-E' SHALL NOT BE INSTALLED IN ENCLOSED LUMINARIES, <ES 150.0(k) BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS: AT LEAST □NE LUMINAIRE IN EACH SPACE SHALL BE CONTROLLED BY A VACANCY SENSOR. ALL LUMINARIES REQUIRING • JAB-2016' OR 'JAB-2016-E' MARKING SHALL BE CONTROLLED BY A DIMMER DR VACANCY SENSOR. EXCEPTION• CLOSETS LESS THAN 70 SQFT. EXCEPTION: HALL 'wAYS. OUTDOOR LIGHTING PERMANENTLY MOUNTED TO BUILDING SHALL BE CONTROLLED BY □NE □F THE F□LL □'wING: PHOT□C□NTR □L AND M□T!□N SENSOR. PHOT□CONTR□L AND AUTOMATIC TIME-S'wITCH CONTROL. ASTRONOMICAL TIME CLOCK. ENERGY MANAGEMENT CONTROL SYSTEM PER CBEES 150.0(K)3Aliic. / w "' :,, X TO S\IITCH ABOVE I!; ENERGY ST AND ARDS 150.0 Ck) A MECH1V<CAL EXHAUST SYSTEM, SUPPLY SYSTEM, DR COMBINATION THEREOF SHALL BE INSTALLED FDR EACH D'wELLING UNIT TO PROVIDE 'wHDLE-;; .c.DING VENTILA TI□N 'wITH OUTDOOR AIR COMPLYING 'wITH ASHRAE c -ANDARD 62.2 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION, AN INTERMITTENTLY DR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM ('wITH OUTDOOR AIR) SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM C □MPL YING 'wITH ASHRAF STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFL□'w RATES SHALL BE 50 CFM ON BATHROOMS AND 100 CFM IN KITCHENS AND SHALL HAVE A NOISE RA TING □F A MAXIMUM OF 3 S□NE. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFL□'w RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH (AIR CHANGES PER HOUR) IN KITCHENS BASED ON KITCHEN VOLUME AND SHALL HAVE A NOISE RATING OF A MAXIMUM OF 1 S□NE. DUCT SEALING AND LEAKAGE TESTING IS REQUIRED PER CEC 150.0 (Ml 11. IF NE'w DUCTS ARE GREATER THAN 40-FEET, FLUORESCENT FIXTURES MUST BE OF THE BALLASTED TYPE THAT ONLY ACCEPTS FLUORESCENT BULBS 'wITH A MINIMUM EFFICACY □F 40 LUMENS PER 'wATT. PRESSURE RELIEF IS REQUIRED FDR TANKLESS 'wATER HEATERS, HOT 'wATER PIPING MUST BE INSULATED PER CEC 150,0 (.J). AS F□LL□'wS• o.. THE FIRST 5'-0' □F HOT AND COLD PLUMBING FROM THE STORAGE TANK. b. ALL PIPING FROM THE HEATING SOURCE TO THE KITCHEN FIXTURES. HIGH EFFICACY LED LIGHTING FIXTURES TD BE OF THE TYPE APPROVED BY CALIFORNIA ENERGY C□MMI3S!□N (CED. tl ~ ~ ---- l:ii::I EXTRA DUTY ru I GARAGE I ~ NOTE• IN DETACHED GARAGES• \l,P, 12;: ♦SLOPE ~ \/ALL MOUNTED FIXTURE \/ITH PH□TO/MDTI□N SENSOR C□MBINATI□N 10• xa• SECTl□NAL DR ~ ..__ r-------------------7 ' ' ' ~ IO'xB'SECTl□NAL DR NOTE, ALL RECEPTACLE OUTLET LOCATIONS SHALL COMPLY \/ITH CEC ARTICLE 210.52. ~ ------ , NOTE• A DISCONNECT MUST BE , INSTALLED IN DETACHED , GARAGES, (NEC 225,30). 10' x8' SECTIONAL DR ~ ALL ELECTRICAL RECEPTACLES SHALL BE SUPPLIED BY AT LEAST □NE 120 V□L T 20 AMP BRANCH CIRCUIT THIS CIRCUIT SHALL HAVE N□ OTHER OUTLETS, (NEC 210,ll(C)(4), 1------IOOA SUB-PANEL \/ITH 30'x36' \IDRKSPACE \/ALL MOUNTED FIXTURE \/ITH PH□T□IM□TION SENSOR COMBINATION II GARAGE ELECTRICAL PLAN II SCALE 1/4'=1'-0' GARAGE DOOR OPENERS SHALLHAVE BATTERY BACK-UP. (SB 969), ELECTRICAL LEGEND SINGLE POLE S'wITCH 3 'vi A Y S'wITCH VACANCY SENSOR DIMMER S'wITCH JUNCTION BOX QUADRAPLEX OUTLET DUAL CONVENIENCE RECEPTACLE DUAL CONVENIENCE RECEPTACLE 1/2 HOT OUTLET DUAL CONVENIENCE RECEPTACLE GFCI 220 VOLT RECEPTACLE \I.P, EXTERIOR RECEPTACLE 'w' ATERPR □□F GFCI GFC! SMOKE DETECTOR-INTERCONNECTED AT NE'w CONSTRUCTION CARBON MONOXIDE DETECTOR-INTERCONNECTED AT NE'w CONSTRUCTION EXHAUST FAN VENT TO OUTSIDE AIR CEILING EXHAUST FAN/LIGHT COMB□ VENT TD OUTSIDE AIR __,,..L.,__ JAB-2019 CEILING LIGHT SURFACE MOUNTED YLED _n_ JAB-2019-E CEILING LIGHT OUTLET RECESSED VLED _Ape JAB-2019 CEILING LIGHT OUTLET 'w / PULL CHAIN YLED i)-,,_ JAB-2019 'w'ALL BRACKET LIGHT ry-LED __,,..L.,__ JAB-2019 HANGING FIXTURE YLED Q FLUORESCENT FIXTURE FWDO l><I \IRAPAR□UND 4-F□□T, 2, 3, DR 4 LAMP 32 \IATTS TB, NORMAL BALLAST w~---ec~ FACTOR, 120 VOLT, SURFACE MOUNTED FLUORESCENT FIXTURE 0 FLOOR OUTLET TELEVISION JACK TELEPHONE JACK TELEPHONE/DATA OUTLET CHIMES • ... ""' DOOR BELL HOSE BIBB w'ITH SHUT OFF AND ANTI-SIPHON DEVICE HOSE BIBB w'ITH ANTI-SIPHON DEVICE "' COLD w'ATER STUB FDR ICE MAKER t---...,..FUEL GAS FG LOOSE KEY VALVE FDR FUEL GAS r:;7 OUTLET FDR GARAGE DOOR OPENER \/ITH REMOTE L:.J SAFETY CONTROLS PER FEDERAL REQUIREMENTS. NOTE• ALL GARAGE DOOR OPENERS IN THIS STRUCTURE SHALL HAVE BATTERY BACK-UP. <SB 969). r:;7 2'x4' SURFACE MOUNTED FLUORESCENT LIGHT L::.J FIXTURE. [I] 4' ELECTRICAL JUNCTl□N BOX SHALL BE PERMANENTLY AND VISIBLY MARKED AS '.fDR. FUTURE ELECTRIC YEHICU E CHARGING'. E.V, READY MEASLES NE\/ S.F.D, \/ITH ATTACHED OR DETACHED GARAGES, AND NE\/ GARAGES \/ITH ELECTRICAL SERVICE. <CBC 92,1.3112), <CBC 92,2,R332), <CALGREEN 4,106.4.D. • THE MAIN ELECTRICAL SERVICE PANEL SHALL INCLUDE RESERVED SPACE ALLD\l!NG FOR THE INSTALLATl□N □F A CIRCUIT BREAKER FDR A FUTURE ELECTRIC VEHICLE CHARGING SYSTEM. • APPROVED MINIMUM 4-INCH SQUARE ELECTRICAL JUNCTION BOX LOCATED ON THE INTERl□R OF THE GARAGE AT MINIMUM 30 INCHES AND MAXIMUM 48 INCHES ABOVE THE GARAGE FL□□R, • MINIMUM I-INCH-DIAMETER LISTED ELECTRICAL METALLIC RACE\IAY □RIGINATING AT THE MAIN ELECTRICAL SERVICE PANEL AND TERMINATING AT THE REQUIRED ELECTRICAL JUNCTION BOX. • ELECTRICAL JUNCTION BOX SHALL BE PERMANENTLY AND VISIBLY MARKED AS :EllR. FUTURE ELECTRIC VEHICILE CHARGING•, REVISIONS w (!) > z 0::: 0 -C 0 ..J 0 LO -0 ...... 0 :::> s <X) LO 0 ...... m z N I t--0 0) zz N I-. ""'" I-<( -c, ..-~ -0 o a en en (.) -co <( t-- N I-.._,., WW LO (J) . t---I cc ...... :::> C <C I w (!) ~ <C (!) I - DRAWN CHECKED OATE SCALE SHEET 12 > 0.. ~-----------------------------------------------------------", _____________________ ,,------------, ELECTRICAL AND MECHANICAL INFORMATION 1, ALL PROJECTS SHALL COMPLY VJTH THE 2019 CALIFORNIA BUILDING CODE AND/OR CALIFORNIA RESIDENTIAL CODE, 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE, 2019 CALIFORNIA ELECTRICAL CODE, 2019 CALIFORNIA MECHANICAL CODE, 2019 CALIFORNIA PLUMBING CODE, 2019 CALIFORNIA FIRE CODE, 2019 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS, AND ALL COUNTY COUNTY OF SAN DIEGO AMENDMENTS. 3, 4. 5, 6. 7. 8. 9. 10, GFCI PROTECTED □Un ETS, FDR LOCATIONS DESCRIBED IN (NEC 210.8(A)• LAUNDRY AREAS, KITCHEN DISHVASHERS, KITCHENS, GARAGES, BATHROOMS, OUTDOORS, \,IJTHIN 6-FEET OF A SINK,. ETC, ARC FAULT PROTECTION FDR All OUTLETS <NOT JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.!2(A), KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC. I UMINAIRE REQUIREMENTS, INSTALLED LUMINARIES SHALL MEET THE EFFICACY AND FIXTURE REQUIREMENTS OF CBEES 150.0(k) PROVIDE PERMANENTLY VIRED, INTERCONNECTED SMOKE DETECTORS VITH BATTERY BACK-UP (SD THAT THE ACTIVATION OF □NE VILL ACTIVATE ALL OF THE OTHERS), IN THE DVELLING UNDERGOING AN ADDITION, AL TERATl□N DR REPAIR AT THE FOLLD\JING LOCATIONS <CBC 907.2.ID.1.2l• al \,/!THIN EACH SLEEPING R□□MJ bl OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDR□□MSJ cl AT EACH STORY \JITHIN THE D\JELLING UNIT INCLUDING BASEMENTS AND HABITABLE ATTICS, (BATTERY OPERA TED SMOKE ALARMS MAY BE USED IN EXISTING AREAS OF BUILDING VHERE VHERE THE INST ALLA TI□N □F SMOKE -ALARMS \JDULD REQUIRE THE REMOVAL OF INTERIOR FINISHES), SH□V PERMANENTLY VIRED INTERCONNECTED CARBON MONOXIDE DETECTORS, HARD VIRED VITH BATTERY BACK-UP FDR NEV CONSTRUCTION AT THE FOLLOVING LOCA TI□NS (CRC R315), al OUTSIDE EACH SLEEPING R□□MJ bl AT EACH STORY VITHIN THE DVELLING UNIT. BATTERY-OPERATED DETECTORS ARE ACCEPTABLE IN EXISTING AREAS VITH ND CONSTRUCTION TAKING PLACE AND IN ALTERATIONS NOT RESULTING IN REMOVAL OF INTERl□R VALL DR CEILING AND \,IITH□UT ACCESS VIA AN ATTIC, CRAVL SPACE, DR BASEMENT, (CRC R315.2) VATER HEATER SEISMIC STRAPPING, MINIMUM TV□ 3/4-INCH-BY-24-GAUGE STRAPS REQUIRED AROUND \JATER HEATERS, VITH 1/4-INCH-BY-3-INCH LAG BOLTS ATTACHED DIRECTLY TD FRAMING. STRAPS SHALL BE AT P□INTS VITHIN UPPER THIRD AND LOVER THIRD OF VA TER HEATER VERTICAL DIMENSl□N, LOVER CONNECTION SHALL OCCUR MINIMUM 4 INCHES ABOVE CONTROLS. <CPC 507,2), GAS APPLIANCES IN [,ARAGES. VATER HEATERS AND HEATING/CODLING EQUIPMENT CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE PLACED ON MINIMUM 18-INCH-HIGH PLATFORM UNLESS LISTING REPORT NUMBER PROVIDED SHOVING JGNITI□N-RESISTANT APPLIANCE. CPC 507.!3 AND CMC 308,1) IMPACT PROTECTION DE APPLIANCES. \JATER HEATERS AND HEATING/C□□LING EQUIPMENT SUBJECT TD VEHICULAR IMPACT SHALL BE PROTECTED BY BOLLARDS DR AN EQUIVALENT MEASURE. (CPC 507,13 AND CMC 308.1,1). ',/ATER CLOSET CLEARANCE, MINIMUM 30-INCH VIDE BY 24-!NCH DEEP CLEARANCE REQUIRED AT FRONT □F VATER CLOSETS. (CPC 402.5). 11. ',/ATER CLOSET EFEICIENCY, ALL VATER CLOSETS SHALL USE MAXIMUM 1.28 GALLONS AVERAGE PER FLUSH, <CPC 403.2), 12. SH□',IER SIZE, SHOVER COMPARTMENTS SHALL HAVE MINIMUM AREA □F 1024 SQUARE INCHES AND BE ABLE TD ENCOMPASS A 30-INCH-DIAMETER CIRCLE. SHOVER DOORS SHALL HAVE A MINIMUM 22-INCH UNOBSTRUCTED \JIDTH. (CPC 408.5 AND CPC 408,6), 13. FIREPLACE APPLIANCES, FIREPLACES VITH GAS APPLIANCES ARE REQUIRED TO HAVE THE FLUE DAMPER PERMANENTLY FIXED IN THE □PEN P□SITl□N AND FIREPLACES VITH LPG APPLIANCES ARE TD HAVE NO 'PIT' DR 'SUMP' CONFIGURATIONS, (CMC 303,7,1), 14, CHIMNEY CLEARANCE. MINIMUM 2-FDOT CHIMNEY CLEARANCE REQUIRED ABOVE BUILDING VITHIN 10-F□□T HORIZONTALLY OF CHIMNEY, THE CHIMNEY SHALL EXTEND MINIMUM 3 FEET ABOVE HIGHEST POINT VHERE CHIMNEY PASSES THROUGH ROOF. <CRC R1003.9), 15. TAMPER RESISTANT RECEPTACLES FDR ALL LOCATIONS DESCRIBED IN NEC 210.52 (ALL L□CATI□NS IN A DVELLING), 16, ELECTRICAL/MECHANICAL PLAN IS SCHEMATIC □NLY AND PER TITLE-24 CALCS FDR THIS PROJECT, LOCATIONS AND SIZES TD BE DETERMINED BY □VNER AS DESIGN BUILD' ITEM. CONTRACTOR TO VERIFY THE F□LL□VING ITEMS DURING BIDDING• Q, SIZE, LOCATION AND MFG □F ALL SUPPLY AND RETURN DUCTS, REGISTERS AND EQUIPMENT (U.N.□. ON DRAVINGS) b. CFM REQUIREMENTS FDR ALL ROOMS. c, L□CA TI□NS AND MFG OF PROGRAMMABLE THERM□ST ATS, d, ELEC. MAIN AND SUB PANEL SIZING CALCULATIONS, e, CUT SHEETS FDR ALL ELEC./MECH. EQUIPMENT, FIXTURES, APPLIANCES, ETC. f. T.V. AND PHONE OUTLET LOCATIONS g. ALL FIXTURE AND SVITCH l□CATI□NS h. DRYER VENT TO EXTERIOR. I. EXHAUST FAN LOCATIONS AND SIZING PER MECH.CODE. 17, EXACT LOCATION □F ALL OUTLETS AND RECEPTACLES SHALL COMPLY \,IITH 2019 CEC ARTICLE 210.52 AND SHALL BE VERIFIED BY D\JNER. 18. COORDINATE EXTERIOR LIGHTING AND PO\JER REQUIREMENTS VITH OVNER, 19, VERIFY ALL METER LOCATION REQUIREMENTS VITH UTILITY CD. (IF APPLICABLE). 20. DUCT SEALING AND LEAKAGE TESTING IS REQUIRED PER (CEC 150 (M) 11 UNLESS NEV DUCTS ARE LESS THAN 40-FEET, 21, CONTRACTOR TD BALANCE HVAC SYSTEM PER CFM REQUIREMENTS AFTER COMPLETING INST ALLA TI□N, 22, NOTE• □PENABLE \,IJNDD\JS SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY PLUMBING VENTS, CHIMNEYS. ETC. (CRC R303.5) 23, GAS VENTS AND NON-COMBUSTIBLE PIPING IN VALLS PASSING THROUGH THREE VALLS □R LESS, SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR □R CEILING, 24, PROVIDE A MINIMUM □F □NE 20 AMP LAUNDRY BRANCH CIRCUIT, SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. <CEC210-tl(C)(2). 25. DRYER VENTS SHALL C□MPL Y \JITH (CMC 504,1.2) AND, al MUST BE A MINIMUM □F 4 INCH DIAMETERJ bl SHALL BE A MAXIMUM OF 14-F□□T COMBINED H□RIZ□NT AL AND VERTICAL LENGTH VITH TV□ 90-DEGREE ELB□vs, c) SHALL HAVE TV□ FEET DEDUCTED FROM THE MAXIMUM LENGTH FDR EACH ELBD\J IN EXCESS OF T\JD, <CMC 504.11). EXEMPTION• PROVIDE MFR'S SPECS. ALL□VING GREATER DUCT SPAN 26. FAU IN ATTIC• MIN, 30'x30' \JDRKING SPACE AT SERVICE SIDE OF C□NTR□LS, CMC 904,10,3, (NOT REQUIRED IF FURNACE CAN BE SERVICED FROM ACCESS OPENING), 27. THE CONTROL VALVES IN SHO\JERS, BATHTUBS, AND BIDETS MUST BE PRESSURE BALANCED □R THERM□sTA TIC MIXING VALVES. CPC SECTI□NS 408, 409, 410. 28. PROVIDE LISTED NON-REMOVABLE TYPE BACK FLOV PREVENTION DEVICE AT ALL HOSE BIBBS. 29. FIREPLACE GAS VALVES MUST BE LOCATED OUTSIDE OF REQUIRED HEARTH AREA, BUT NO MORE THAN 48 INCHES. 30, 31. 32. A DEDICATED MINIMUM OF ONE-20 AMP CIRCUIT FOR BATHRO□M(S) OUTLET. SUCH CIRCUIT SHALL HAVE ND OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN □NE BATHROOM, <CEC 210-ll(Cl (3), A MINIMUM □F TV□ SEPARATE 20 AMP CIRCUITS SHALL BE PREJVIDED TD THE KITCHEN APPLIANCES, THE TV□ DR MORE SMALL -APPLIANCE BRANCH CIRCUITS SHALL HAVE N□ OTHER OUTLETS. (CEC 210.52b), BATHROOM EXHAUST FANS SHALL BE HUMIDITY CONTROLLED PER CMC CHAPTER 4 AND CALIFORNIA GREEN BUILDING STANDARDS CODE CHAPTER 4, DIVISION 4.5. 33. KITCHEN DISH\JASHER BRANCH CIRCUIT• GFCI PR□TECTl□N SHALL BE PROVIDED FOR OUTLETS THAT SUPPLY DISHVASHERS INSTALLED IN DVELLING UNITS, <CEC 210.8(Dl, --------------------------------- ENERGY EFFICIENCY REQUIREMENTS LUMINARIES, ALL LUMINARIES SHALL BE HIGH EFFICACY IN ACCORDANCE v/ITH ENERGY STANDARDS TABLE 150,0-A ALL LED LUMINARIES AND LAMPS SHALL BE MARKED 'JAB-2019' AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DATABASE. ALL RECESSED DDv/NLIGHT AND ENCLOSED LUMINARIES SHALL BE MARKED • JAB-2019-E' AND LISTED IN THE CALIFORNIA ENERGY COMMISSION DATABASE. LUMINARIES MUST HAVf A LABEL CERTIFIED FDR AIRTIGHT CONSTRUCTION. LIGHT SOURCES NOT MARKED 'JAB-2019-E' SHALL NOT BE INSTALLED IN ENCLOSED LUMINARIES. <ES 150.0(k) BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH SPACE SHALL BE CONTROLLED BY A VACANCY SENSOR. ALL LUMINARIES REQUIRING • JAS-2019' DR • JAB-2019-E' MARKING SHALL BE CONTROLLED BY A DIMMER DR VACANCY SENSOR. EXCEPTION• CLOSETS LESS THAN 70 SQFT. EXCEPTION• HALL\,/AYS. OUTDOOR LIGHTING PERMANENTLY MOUNTED TD BUILDING SHALL BE CONTROLLED BY ONE OF THE FDLLD\,/ING• PH□TDC□NTRDL AND MDTIDN SENSOR, PHDTDCDNTRDL AND AUTOMATIC TIME-Sv/ITCH CDNTRDL. ASTRONOMICAL TIME CLOCK. ENERGY MANAGEMENT CDNTRDL SYSTEM PER CBEES 150.0(K)3Aiilc. HIGH EFFICACY LED LIGHTING FIXTURES TD BE OF THE TYPE APPROVED BY CALIFORNIA ENERGY COMMISSION (CEC). TO SVITCH BEL□V LED I ~ --------------- ..___ __ ,-,-i_LED ---- ENERGY STANDARDS 150.0 (k) A MECHANICAL EXHAUST SYSTEM, SUPPLY :!iYSTEM, DR C□MBINA TIDN THEREOF SHALL BE INSTALLED FDR EACH Dv/ELLING UNIT TD PROVIDE \,/HOLE -BUILDING VENTILA TI□N \,/ITH DUTD[l□R AIR CDMPL YING \,/ITH ASHRAE STANDARD 62.2 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. AN INTERMITTENTLY DR CONTINUOUSLY OPERATING LOCAL MECHANICAL EXHAUST SYSTEM (\,/ITH OUTDOOR AIR) SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM CDMPL YING \,/ITH ASHRAE STANDARD 62.2-2007 AS ADOPTED BY THE CALIFORNIA ENERGY COMMISSION. INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLD\,/ RATES SHALL BE 50 CFM ON BATHROOMS AND 100 CFM IN KITCHENS AND SHALL HAVE A NOISE RATING OF A MAXIMUM OF 3 SDNE. CONTINUOUS LOCAL VENTILATION EXHAUST AIRFLO\,/ RATES SHALL BE 20 CFM IN BATHROOMS AND 5 ACH (AIR CHANGES PER HOUR) IN KITCHENS BASED ON KITCHEN VOLUME AND SHALL HAVE A NOISE RA TING OF A MAXIMUM OF 1 SDNE. DUCT SEALING AND LEAKAGE TESTING IS REQUIRED PER CEC 150.0 (M) 11. IF NE\,/ DUCTS ARf GREATER THAN 40-FEET. FLUORESCENT FIXTURES MUST BE OF THE BALLASTED TYPE THAT □NL Y ACCEPTS FLUORESCENT BULBS \,/ITH A MINIMUM EFFICACY OF 40 LUMENS PER v/ATT. PRESSURE RELIEF IS REQUIRED FDR TANKLESS \,/ATER HEATERS. ALL DOMESTIC HOT \,/ATER PIPING MUST BE INSULATED PER CEC 150,0 (J), AS SPECIFIED IN (CPC 609.ID• 1/2' PIPE -(1/2' INSULATION); 3/4' PIPE -(1' INSULATION); 1' TD 1-1/2' PIPE -(1-1/2' INSULATION), u) ADDITIDNALL Y THE 1/2' HDT-v/ATER PIPE TD THE KITCHEN FIXTURES, AND THE CDLD-v/ATER PIPE v/ITHIN 5-FEET OF THE \,/ATER HEATER BOTH REQUIRE I-INCH MINIMUM INS ULA TIDN. (ES 150,□(j), ----------::;-, NOTE, ALL RECEPTACLE OUTLET L□CATI□NS SHALL C□MPL Y VITH CEC ARTICLE 210.52. II UPPER FLOOR ADU ELECTRICAL PLAN II SCALE 1/4'=1'-0' DURING CONSTRUCTION ALL DUCTS AND OTHER AIR DISTRIBUTION EQUIPMENT SHALL BE COVERED \JITH TAPE, PLASTIC, SHEET METAL, DR OTHER METHODS TD REDUCE THE AMOUNT OF DUST DR DEBRIS VHICH MAY COLLECT IN THE SYSTEM. ELECTRICAL LEGEND SINGLE POLE Sv/lTCH 3 'wAY S'wITCH VACANCY SENSOR DIMMER S'wITCH JUNCTION BOX QUADRAPLEX OUTLET DUAL CONVENIENCE RECEPTACLE DUAL CONVENIENCE RECEPTACLE 1/2 HOT OUTLET DUAL CONVENIENCE RECEPTACLE GFCI 220 VOLT RECEPTACLE \J.P. EXTRA DUTY 'wATERPRDDF GFCI GFCI SMDKE DETECTOR-INTERCONNECTED AT NE\,/ CDNSTRUCTIDN CARBON MDNDXIDE DETECTOR-INTERCONNECTED AT NE\,/ CONSTRUCTION EXHAUST FAN VENT TD OUTSIDE AIR CEILING EXHAUST FAN/LIGHT CDMBD VENT TD OUTSIDE AIR __A_ JAB-2019 CEILING LIGHT SURFACE MDUNTED YLrn A JAB-2019-E CEILING LIGHT OUTLET RECESSED -YLED _A_pc JAB-2019 CEILING LIGHT OUTLET 'w / PULL CHAIN YLrn LA_ JAB-2019 'wALL BRACKET LIGHT ryri.ED ~EDJAB-2019 HANGING FIXTURE Q FLUDRESCENT FIXTURE FLUOR l><I VRAPAROUND 4-F□[]T, 2, 3, DR 4 LAMP , 32 VATTS TS, NORMAL BALLAST ~~---= FACTOR, 120 VOLT. SURFACE MOUNTED FLUORESCENT FIXTURE 0 FLOOR OUTLET TELEVISION JACK TELEPHONE JACK TELEPHONE/DATA OUTLET CHIMES DOOR BELL H.B. HOSE BIBB 'wITH SHUT OFF AND Sill ANTI-SIPHON DEVICE HOSE BIBB 'wITH ANTI-SIPHON DEVICE ~ COLD 'wATER STUB FDR ICE MAKER 1---i~FUEL GAS FG LOOSE KEY VAL VE FDR FUEL GAS r.7 SINGLE TUBE FLUORESCENT FIXTURE UNDER L::.J CABINET, (20 VATTS PER LINEAL FOOT MAX), PENETRATIONS OF FIRE RESISTANT \JALLS, FLOOR-CEILINGS AND ROOF -CEILINGS SHALL BE R□TECTED AS REQUIRED IN CRC SECTION R302.4, NOTE, ALL RECEPTACLE OUTLET LOCATIONS SHALL COMPLY VITH CEC ARTICLE 210.52. ARC-FAULT PROTECTION FDR ALL DUTI ETS (NOT JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.12(A), KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC. ELECTRICAL DEVICES INSTALLED IN WELLINGS· TAMPER RESISTANT RECEPTACLES FDR ALL LOCATIONS DESCRIBED IN SECTION NEC 210.52 (I.E. ALL RECEPTACLES IN A D\JELLING), (CEC 406,12), NOTE• THE INST ALLING CONTRACTORS ARE RESPONSIBLE FDR THE QUANTITY AND SIZING OF HEATING, CODLING AND DHV EQUIPMENT, DUCT SIZING AND EQUIPMENT SELECT!□N, REVISIONS w (!) > -z 0::: 0 -C 0 ..J 0 LO -0 ...--0 ::::, s CO LO 0 ...--CCI z N I om~ zz I-. v I-<( ---(!) ~ -0 (.) 0 (/) (/) (.) -c.o <( r-- NI-.._ WW LO (/) . r---I cc ...--> a.. ::::, C <( I w (!) ~ <( (!) I - DRAWN CHECKED DATE SCALE SHEET 13 S, PANEL 5/8'xl2' ANCHOR B □L TS 4'-0' 0/C, AND 12' FROM CORNERS, U,□,N, MINIMUM T'w□ BDL TS PER PIECE \./ITH □NE B □L T <IF OCCURS) 2X P.T,D,F. MINIMUM 7' EMBEDMENT LDCA TED NOT MORE THAN 12' DR LESS THAN 4', MINIMUM 3'x3'x0,229' PLATE 'wASHERS AT EACH B□L T, E.N.,-----_\._ • "' • a, • • • I»' t> •• •• • • I> #3 RE/BAR 18' EA, \./AY , . .,:;{: :,<:;(;.'.i;/ .. ~; 2' SAND FILL ~ ~ /---~.;~\:.J::::-':/t::~\-.-·-~ 2' SAND FILL 10 MILL V AP□R BARRIER • (2)-#5 RE/BAR TOP AND BOTTOM U,□,N, • 3' CLEAR +-15' -----+ GARAGE FOOTING t 2'-0' MIN, LAP t 2'-0' MIN, LAP -t TOP PLATE 2-2x PLATES WHERE T[]p DR SOLE PLATES ARE CUT FDR PIPES, A METAL TIE MIN, 0,054 INCHES THICK AND 1-1/2 INCHES WIDE SHALL BE FASTENED ACROSS THE OPENING WITH (8)-IOcl NAILS EACH SIDE. THE STRAPS SHALL NOT EXTEND LESS THAN 6' BEYOND THE CUT DR NOTCH, (CRC R602.6,D, PROVIDE DOUBLE TOP PLATE WITH MINIMUM 24' LAP SPLICES, PROVIDE (8)-16cl LAP SPLICE NAILING. <CRC R602,3.2). 9' SILL B□L TS TD BE 5/8' DIA, WITH 7' EMBEDMENT AT 4'-0' □IC, DR 'RAMSET' !CB□ lt:1639/1147 <SEE SHEARWALL SCHEDULE FDR SPECIAL CONDITIONS), @ @ @ SILL PLATE WHERE SILL PLATE IS~~ DRILLED DR NOTCHED MORE THAN 1/3 THE PLATE \,/IDTH, INSTALL □NE BDL T EACH SIDE @ @ TYPICAL SILL PLATE ANCHORAGE AND TOP PLATE SPLICE N□TE, PROVIDE A MINIMUM □F TWO ANCHOR BOLTS PER PIECE □F SILL PLATE, BOLTS SHALL BE INSTALLED WITH PR□PERL Y TIGHTENED NUTS AND WASHERS. SIMPSON 'U' RIDGE BEAM PER PLAN SIMPSON 'LSTA18' @ 48" OC; MAX ROOF RAFTER PER PLAN RIDGE BEAM CONNECTION 2x BLKG LTP4 @ 24" OC MAX; UNO FASCIA EN SHEARWALL PER PLAN WHERE OCCURS BN "'- SHEAR TRANSFER RAFTER PER PLAN AT R □□F • POST OR BUILT UP ----1-o- STUD PER PLAN w/ EN SLAB ON GRADE PER PLAN , ~IL I¾' MIN. HOLDDOWN PER PLAN AND SCHEDULE SIMPSON ANCHOR SOLT PER HOLDDOWN SCHEDULE ! f:::i,::,S:t:s:£~~~'.._c___:-lf y i · ~7--:rr&':M"n.:':I EXTENSION SCHEDULE .. '• i'·/ / z :,: "' I-..J 0. 0. HOLD ANCHOR LENGTH OF DOWN BOLT EXTENSION HDU2 SSTB16 26" HDU4 SSTB20 34• HDU5 SSTB24 42• HDQB SSTB28 so· HHDQ11 SB1x30 45• HHDQ14 S81x30 45• • • .. i WIDTH ii PER PLAN 1-1/2" 3• CLEAR DEEPEN FOOTING AS REQUIRED; EXTEND 24"EA. SIDE OF HOLDOWN. w"' Aw 0. FOOTING EXTENSION CENTERED ON HOLD--.. H □LDD\./N AT GARAGE F □□TINGABLE B / ,.__ __ _._ . .. 1K-:·.:o:: :., ... ·, •, '· DD NOT EXCAVATE PIPE TRENCH PARALLEL TD FOOTINGS BELOW THIS LINE. PLARALLEL 2 , ·<,; ~ .-~, Q ' __ J_~h==:;:-------ALL PIPE SLEEVES 2' -LARGER THAN PIPE DD NOT PLACE PIPE IN THIS AREA, CONCRETE FILL TD BE PLACED BEFORE FOOTING IS POURED. MAKE SAME WIDTH AS FOOTING AND FULL WIDTH □F TRENCH <TRENCH = SLEEVE DIA. + L-6'). ---.--------------------"1'-----'-'----'"c..:___:_t>_· --"·-· -·~--'1.3' PERPENDICULAR TRENCH SPACING SIMPSON 'U' HANGER CAL JOIST PER PLAN BEAM PER PLAN JOIST TD BEAM 2X10 ROOF PAD \.// 3-16d INT□ EA. TRUSS DR R.R, FILL --B,N, CAL-FILL ~~...._ SEE ROOF PLAN SUPPORT SLAB ON GRADE (PER PLAN) 0 0 ~-w□□D POST IN WALLJ (PER FRAMING PLAN), 1 z "' ..J 0. "' w 0. REINFORCING (PER PLAN) -¥---PER PLAN (2'-0' SQ, MIN). ---+ INTERIOR PAD FTG CIN \./ALL) d clD HOOK 90• BEND I, 1 LAP AND OFFSET R STIRRUP DR TIE 45• BEND NOTE• 'R'=3cl FDR #2 TD #8 'R'=4cl FDR #9 BARS DR LARGER <TYPl. TYPICAL REINFORCING BAR BENDING WOOD SIDING OVER (2) LAYERS TYPE 'D' FELT PAPER. E.N. SHEATHING TO BLOCKING SHEARWALL PER PLAN WHERE OCCURS 6x12 SOLID BLOCKING ALONG LEDGER B.N. '"""'.r-f~+---(2) SIMPSON SDS25412 AT 16" 0/C. ,=aala#-l+---16d NAILS AT 6" 0/C. (STAGGERED) JOIST PER PLAN JOIST HANGER PER PLAN SOUD 2x BLOCKING CEILING JOIST TD LEDGER M CS16 STRAP OVER FULL LENGTH OF WALL; FULLY NAILED. INSTALL OVER SHEATHING AND NAIL INTO BLOCKING w / EDGE NAILING r L TP4 PER SCHEDULE HEADER PER PLAN I PROVIDE EDGE NAILING PER SCHEDULE AT ALL PANEL EDGES. USE 3x NOMINAL MEMBERS WHERE REQD BY SCHEDULE !.J.--lj..,L-"J.l--.,Ll..l..-1--HOLDDOWN POST TRIMMER ~--11 PER PLAN; DBL STUD MINIMUM WHERE NONE NOTED SILL CONNECTION PER SCHEDULE , H..-+--HOLDDOWN OR STRAP PER PLAN FORCE TRANSFER AROUND SHEAR\./ALL OPENING 42clb LAP TYPICAL - , I . FOOTING PER PLAN 1 FOOTING /, REINFORCING PER PLAN I· I. • <· • • • - ·• • • . • .... -~ ' . •. . "<> • ' . . . . • • . .. • ·• . ' • . .. . . •• • • . •· • ' . : ... •·<I • A ' .. • ' .. • ' • •• ' CLEAR TYPICAL • • • ,· . • REINFORCEMENT INTERSECTIONS AT FOOTING START CURING □F SLAB AS EARLY AS POSSIBLE. USE A MEMBRANE SPRAY, WATERPROOF PAPER, OR POLYETHYLENE SHEETS. t> SPACE SAW-CUT J□INTS PER PLAN. "'T'/4 ·, • ·4 .· • . -+------'--!--SLAB SUB-BASE . . . . . --. ·. . (PER PLAN), ------+--COMPACTED SUB-GRADE. NOTE• SAWCUT SLAB TD BE MADE AS EARLY AS POSSIBLE (4 TD 12 HOURS AFTER FINISHING>. EXPECT SLIGHT RAVELING AT J□INT EDGES. CONTROL JOINT \./DOD POST -- <PER PLAN) SIMPSON MST36 STRAP TIE <BOTH SIDES) INSTALL PER MFR'S SPECS USING APPROVED SIMPSON FASTENERS 'w□□D BEAM <PER PLAN) \./ODD POST <PER PLAN) ' ' ' ' ' ' ' ' . ' ' ' . ' • • • ' • • • • • • • • • • ' ' ' OTHER STRUCTURAL ELEMENTS NOT SHD\./N FDR CLARITY POST TD HEADER CONN. 16d AT 16' 0/C. MAX. (2)-2x SILL PLATE TYPICAL \,/ ALL SIMPSON ST-12 STRAP __..-,-_ <2l-2x TOP PLATE SOLID HEADER BEAM (PER PLAN) WITH 5-16cl END NAILS AT EACH END, t----2x KINGSTUD 1-M----2x TRIMMER (CONT TD SILL PLATD. 2x CRIPPLES (16' □/Cl, (2)-16cl HDGV NAILS 2x PTDF FRAMING (NJ FOOTING FINISHED GRADE TYPICAL FOOTING TD DAYLIGHT 2x STUD WALL <TYP). CLG, J□ISTS (PER PLAN), <] SHEARWALL WHERE OCCURS (SEE FRAMING PLANS). ~-SILL NAILING (PER SW SCHEDULE) ~~~~~~E.N. ~-GYP BRD (PER PLAN) 2x BLOCKING AT 24' D/C, 2x RIM. LTP4 PER SW SCHEDULE WHERE SW OCCURS ABOVE L TP4 AT 24' 0/C, MAX ELSEWHERE, <] SHEARWALL WHERE OCCURS (SEE FRAMING PLANS), SHEAR TRANSFER AT EXT \./ALLS ROOF RAFTER PER PLAN BN EN 'G' WALL FULL LENGTH LllP4 @ 24" QC MAX; UNO EN 2x FLAT W/ (2) 16d NAILS AT EACH ROOF RAFTER. 2x BLOCKING LllP4 @ 24" OC MAX; UNO SHEAR TRANSFER □ \./EATHERLAP 12' 'M□IST□P NEXT' FLASHING AS INDICATED. \./IND□'w, DOOR, DR OTHER FRAMED PENETRATION. (SEE ELEVATION) -------SEAL BET\./EEN FLANGE AND n-:J.;;=:;:;=;:;::;~:,1f FLASHING \./ITH 'M□IST□P' POLYMER SEALANT, <ABOVE AND BELO\./), --LAP 3' MIN, AT H□RIZ, JOINTS mif:iQJ~ LAP 6' MIN. AT VERT, J□INTS \./ATER RESISTANT BUILDlNG PAPER '60 MINUTE' GRADE 'D' 'wEATHER LAP TD SHED \./ATER TD EXTERIOR TYP, (2-LAYERS IF APP), NOTE• THIS DETAIL APPLIES TD ALL PENETRATI□NS, SEE EXTERIOR ELEVATIONS, FDR STUCCO, \./DOD TRIM, OR OTHER FINISH, * PROVIDE \./EATHER PR□TECTI□NJ INCLUDING FLASHING DETAIL FLASHING AND COUNTER FLASHING PER 2016 CRC AT ALL EXTERI□R \./ALLS. REVISIONS w (!) > -z 0:::: 0 -C 0 ..J 0 LO -0 ...... 0 ::> s Cl() LO 0 ...... cc z N I t--0 0) zz N 1--. -.:;t 1--<( -(!) ,......._ ~-0 (.) 0 (.) -(0 u, u, <( t--N 1--.__, WW LO Cl) . t---:r: cc ...... > a.. ::> C <C I w (!) ~ <C C) I - DRAWN CHECKED DATE SCALE SHEET SDl SIMpson Strong-Tie • fl fl fl fl • • • • COLUMN CAP CCQ66SDS2.5 LSTA24 TIE AT RAFTER OVER RIDGE AT 48' 0/C. 2X RIDGE 2' LARGER THAN ROOF RAFTERS (SEE PLAN) CAL-FILL RIDGE DETAIL S, PANEL (IF OCCURS> 2X P.T.D.F, MINIMUM 7' EMBEDMENT E.N,--.._ • (X) • • 5/8'x12' H.D, GAL V, ANCHOR B□L TS 4'-0' 0/C, AND 12' FROM CORNERS, U,0,N, MINIMUM T\./0 B□L TS PER PIECE \./ITH ONE BOLT LOCATED NOT MORE THAN 12' DR LESS THAN 4' FROM EACH END OF EACH PIECE. 3'x3'x0.229' H.D. GAL V, PLATE WASHERS AT EACH B□L T. #3 RE/BAR 18' EA, \./ A Y "'~ 10 MILL VAPOR BARRIER (2)-#4 RE/BAR TOP AND BOTTOM U.□.N, t ~' -_ . ~ ... :--·~··We_~. J~_:-_:,:- /. " 3' CLEAR 4--12·~ EXTERIOR CONT FOOTING BEYON SLAB ON GRADE PER PLAN MOISTURE RETARDER PER PLAN ✓ r z :,:<I: I-..J o..O.. WO< AW 0.. BASE PER PLAN • -• d . • "'. . . . REINFORCEMENT PER PAD FOOTING SCHEDULE FOOTING •· -1----WALL POST PER PLAN A35 EA SIDE TO POST ANCHOR BOLT BEYOND z -"' • (X) • _ fz:_z::!· _12_ :z_ -,z:. =:;,_ ::<;z-;,/r,<-~ ·-/ . .,_. ' • .d -~ .4 • • .4. ·-. •• PAD FOOTING AT EXTERIOR \J ALL Post size by Designer •• • • • • Q. 0 • HDU5 (HDU2, HDU8, HDU11, and HDU14 similar) SIMPSON HOLDOwN • -2x4 FLAT OUTRIGGER @ 16 DC BN JP4@ 24" DC\ MAX; UNO L \ •► EN FASCIA ~ ROOF RAFTER RWALL PER PLAN [:) \\!,ERE OCCURS SHEA . V SHEAR TRANSFER AT ROOF ~-HOLDDOWN POST OR BUILT UP---+.-PER PLAN AND STUD PER PLAN w/ EN SLAB ON GRADE PER PLAN EXTENSION SCI-EDULE HOLD ANCHOR LENGTH OF DOWN BOLT EXTENSION HDU2 SSTB16 26" HDU4 SSTB20 34• HDU5 SSTB24 42" HDQB SSTB28 50" HHDQ11 SB1x30 48" HHDQ14 SB1x30 48" • • SCHEDULE SIMPSON ANCHOR BOLT PER HOLDDOWN SCHEDULE .. ·. ... : .ll. d .,-'--~!--.4_ --"I.-DEEPEN FTG 3• CLEAR AS REQUIRED . < • \IIDTH PER PLAN 1-112· FOOTING EXTENSION CENTERED ON HOLD DOWN PER TABLE HOLDD'v/N AT NE'v/ FOOTING ~-PLll □□D SHEATHING <PER ROOF FRAMING PLAN) 2x10 ROOF-~ RAFTERS (PER PLAN), B,N, lxB SHIP-LAP DR 1/2' EXT PLYSAIIN AT EXPOSED OVERHANG. 2x SHAPED SOLID BLOCKING 111TH A35 PER SHEAR SCHEDULE, 24' □IC, MAX EVERYIIHERE ELSE SHEARWALL WHERE OCCURS; G OTHERWISE >W-----CEMENTITI□US SIDING (BY □IINER) □VER (2) LAYERS GRADE 'D' PAPER. SHEAR TRANSFER 0 3' MINIMUM SIDEC□VER (2' FDR LCB) SIMPSON COLUMN BASE GAR DR HDR (PER PLAN) \./DOD SIDING OVER (2) LAYERS TYPE 'D' FELT PAPER . "' ..J u • (\J - -------2-LAYERS '· .i..-~ BUILDING PAPER. IM------12' \./IDE FLASHING PAPER. GARAGE DOOR TRACK, -------2x JAMB DOOR SECTION ~-CONTINUOUS WEATHER-STRIPPING. LINE OF JAMB (BEYOND) GARAGE DOOR HEADER BN ENTIRE LENGTH OF Bl.KG 2x BLKG MIN; USE 4x BLKG l'IHEN REQUIRED TO ACCOMODATE STRAP WIDTH JOISTS PER PLAN DBL TOP PLATE STUD WALL • \ STRAP PER PLAN; EXTEND ENTIRE LENGTH OF THE BLOCKING AND 48" MIN OVER THE STUD WALL IF STUD WALL IS LESS THAN 48" LONG EXTEND STRAP ENTIRE LENGTH OF WALL BLOCK AND STRAP CONN SHEARWALL PER PLAN \\!,ERE OCCURS; G OTHERWISE GIRT PER PLAN --- SN LTP4 PER sw-~---JIL! SCHEDULE 111,ERE SW OCCURS ABOVE; L JP4 @ 24" MAX OC ELSEWHERE EN SHEARWALL PER PLAN 111,ERE OCCURS; G OTHERWISE GIRT SECTION -------------------- CALIF. FRAMING -- OVER CONT, ROOF SHEA THING BELO\./ RIDGE BOARD @-BAY WIDTH X 30' ACCESS AND VENTILATION OPENING. PROVIDE 2X BLK'G AND EDGE NAILING OF ROOF SHEATHING AROUND OPENING, TRUSSES AT------ 24' 0/C, RID E PURLIN VALLEY JACKS CAL-FILL SUPPORT NEW SLAB EXISTING FOOTING DOWELS SIZE AND SPACING TO MATCH SLAB REINFORCING EMBED BARS 6" INTO (E) FTG w/ SIMPSON SET-XP EPOXY (ICC ESR-2508) 4 TYPICAL EXISTING NE\./ SLAB FOOTING TD CONN ® BN SIMPSON 'H2.5A' @ 32" OC 16d Cl 6" OC 2x BLKG C 32" OC ROOF RAFTER PER PLAN SHEAR PANEL PER SHEARWALL SCHEDULE; TYPE G OTHERWISE 2x BLKG Cl 32" DC --- EN SHEARWALL l'IHERE OCCURS SEE PLANS BN EN TO SHEA THING 2x BLKG SN 2x RIM BOARD FLOOR JOIST PER PLAN L TP4 PER SHEARWALL SCHEDULE l'IHERE S. W. OCCURS ABOVE; LTP4 Cl MAX 24" O.C. ELSEWHERE I SHEAR TRANSFER AT L □w ROOF N SHAPED HANDRAIL TYPE 8. DESIGN TD BE SELECTED BY OWNER HANDRAIL BRACKET TYPE 8.----__J DESIGN TD BE SELECTED BY OWNER-BRACKET 48' □IC. \.I I 2 #10 \./DOD SCREWS \./ / 1-1/2' EMBED 34' MIN, 38' MAX. 48' 0/C, INTERIOR FINISH -------1- 2x BLOCKING-------------++--" VERIFY \./ / MANUF. MIN, BACKING 36' MIN TREAD HANDRAIL DETAIL PLY'w'DDD PLYIJODD SHEATHING SHALL BE CONTINUOUS UNDER CALIFORNIA FILL VALLEY JACKS SPACED 24" □IC, CLEAR SPAN NOT T□ EXCEED e·-o•, F□R SIZE AND GRADE SEE END JACK CHART □R RAFTER SPAN TAELE UNDER APPROPRIATE C.S.I. LOADING. VALLEY PADS: 2X10 OR <2>-2X6, JACK POSTS 2X4'S TD BE PLACED UNDER VALLEY JACKS AT N□ M□RE THAN 8'-0' DIC, AND NAILED TD JACK PURUNS, JACK PURLINS 2X4X4'~0' SPANNING □VER THREE TRUSSES UNDERNEATH AND PARALLEL T□ VALLEY JACKS T□ \/H-ICH THE JACK P□sT SUPP□RTS ARE NAILED, RIDGE BOARD MINIMUM 2X6 DOUGLAS FIR. RIDGE POS:T 2X4'S T□ BE PLACED UNDER RIDGE B□ARD AT ND MORE THAN 5'-0' □IC, AND NAILED T□ RIDGE PURLIN. RIDGE PURLIN 2X4'S w'H□S£ LENGTH IS 1/2 THE VALLEY WIDTH AT THE POINT INDICATED BY THE RIDGE P□ST, ALL NAILING PER CRC 2016 VALLEY JACKS AT 24' □IC. RIDGE BOARD END \./ALL, GABLE END OR GIRDER TRUSS, NOTE, ATTACH RIDGE/PURLINS TD POSTS w'ITH 3-16d NAILS. CAL -FILL SUPPORT JACK POST ~---------NEW FOOTING EXISTING FOOTING-~ DOWELS TO MATCH FOOTING REINFORCING MIN 8' t 4 4. 4 q 4 q 4 LI. -· 4 q • <1 4 . q .d ··':7 q • • 4 • •,i q • q q. .,__ ____ 36' LAP -----~ EMBED BARS 8" INTO (E) FTG w / SIMPSON SET-XP EPOXY (ICC ESR-2508) TYPICAL FOOTING NE\./ TD EXISTING CONNECTION MINIMUM RUN Of 10', NOSING• 3/4' MIN, TD 1-1/4' MAX, MINIMUM RUN IS 10', MEASURED FROM THE NOSING PRDJECTl□N, WHERE THERE rs ND NOSING, THE MINIMUM RUN IS 11', (SECTI□N R311,7), ~ RISE BETIIEEN 4' ----'~I.-AND 7-3/4'. ~Ill II II 5/8' TYP X GYP BRD TYPICAL TREAD N□SINGS BETWEEN 3/4' AND 1-112•, PROVIDE 2X P.T,D.F, --' SLEEPER DR FELT VAPOR BARRIER AT STRINGER TD CONC. CONN. 2X4 BLK'G 48'□/C, STAIR • CD ' "' 1-1/8' PL Y\./DDD TYPICAL AT TREADS. ~-1/2' PL Y\./DDD TYPICAL AT RISERS. 14'xl-1/4' 1.5E TIMBERSTRAND LSL (3) MIN, STRINGERS CONC SLAB (PER PLAN), POWER DRIVEN FASTENERS BY HIL TI DR APPROVED EQUAL 12' 0/C, ST AIR STRINGER TD SLAB ---------------------------- (!) z -C ...J -:::::, REVISIONS m zz -(!) ~ -Cl) Cl) WW cc DRAWN CHECKED DATE SCALE SHEET SD2 (E) 5,25'xl!,25' PSL FL BM (E) 2x10 FL□□R J□ISTS.-----, AT 16' D/C, (2) SIMPSON A35'S (Nl STAIR STRINGERS - (PER PLAN), ~ X <> ... 0 ' lo ,.. ,,,.. ' ~: c(i , ' I 0 , , I <N> 6x8 FILLER BLOCK , ' ATTACH IIITH , ' 5/8' DIA. x 12' LAGS 12 V □IC, (STAGGERED), < ~ (4)-1,25' LSL STAIR STRINGERS <REINFORCE 111TH CONTINUOUS 2x8 FUSH TD BOTTOM EDGE 111TH !Od NAILS 12' D/C. STAGGERED). STAIR STRINGER TD BEAM I "' ◄ 0 £, SiMpson Strong-T~ / HUC (on post) GIRT CONNECTION TD POST REVISIONS w (!) > z 0::: 0 -C 0 ...J 0 LO ----0...--o - 'B" I/ C" I/ D"' i'E" ::, $ CX) LO o...-CD ZC\1 1 ' / '-./ '-/ '-/ QO>~ zz I-. -.;:t -c, I-(5 ,_ ~-0 0 C) -co en en <( r-- WW C\l I-----LO Cl) . cc r---I ...... > a.. DRAWN CHECKED DATE SCALE SHEET SD3 -----------·-------------------