Loading...
HomeMy WebLinkAbout2235 PALOMAR AIRPORT RD; ; FA010018; Permit6/2/22, 9:11 AM FAOI 0018 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA010018 2235 PALOMAR Job Address: Status: ISSUED AIRPORT RD Permit Type: FALARM Applied 6/18/2001 Parcel No: Approved: 6/22/2001 Lot #: 0 Reference No.: Issued: 6/22/2001 PC #: Inspector: Project Title: CARLSBAD SELF STORAGE Applicant: Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 171 0 171 0 1/1 Submittal package for: CARLSBAD SELF STORAGE 2235 Airport Rd. Carlsbad, CA. 92008 Protection One 1715 E. Wilshire, #720 Santa Ana, CA 92705 Contains Cutsheets and CSFM listings for: Fire alarm control panel Smoke detector Heat detector Manual pull station Horn/strobe Waterfiow switch OS&Y tamper M E.AL California (.. State Fire 122-96-E ç5T) MarshI• 7165-0075:177 MS-5210L1D February 13, 1998 A3-400 I MS-521 I Fl reLrreALarrn S I Fire Alarm Control Panel with built-in DACT ncorporaTeo and remote-site Upload/Download capability I Section: Control/Communicators i GENERAL The Fire-Lite MS-5210U0 is a 24-volt, ten-zone fire alarm control panel with built-in communicator and remote-site Upload/Download capability (requires panel software se- vision #MS52103.0 or greater). The integral communica- tor transmits event information (alarms, troubles, supervi- sories, faults, etc.) to a UL listed central station. Select- able transmission formats allow the MS-5210UD to com- municate to virtually all central stations. FEATURES Ten programmable Initiating Device Circuits (zones). Each zone may be programmed for. ./Two-wire smoke detectors. / N.O. contact devices (pull, heat). / Four-wire smoke detectors. / Waterfiow operation (silenceable or nonsilenceable). / Supervisory operation. / Auto-reset supervisory operation. / Remote switch for Reset, Drill, Silence and Acknowl- edge. ,f Auto-reset or latching, critical and noncritical process monitoring. Zones programmed for process monitoring require a contact closure for activation and can be used to monitor: / Temperature (high/low temp). / Loss of air flow. / Water level. V Gas detection. / Open/Close. /Refrigeration. /Tamper (non-fire). Two built-in, Class B (Style Y) Notification Appliance Circuits (NACs) - expandable to four. Notification Appliance Circuits may be programmed: / Silenceable. I Non-Silenceable (a strobe circuit can keep flashing after the panel is silenced). ./Auto-Silence (program 5 to 30 minutes). / Silence Inhibit (60 seconds). /Coding (March Time, Temporal, California). 3.0 Amps of Notification Appliance power, expandable to 6.0 amps (meets the critical power requirements for ADA and UL-1971 devices). Two built-in, fully programmable Form-A relays - expand- able to four with two Form-C relays. Dual-line rotary- or Touch-Tone®-dial DACT interfaces to public telephone network (leased phone lines are not required). 24-Volt operation. Built-in voltmeter measures: / Zone voltage. ,(Primary AC line voltage. / Battery voltage. / Notification Appliance Circuit(s) voltage. / Resettable 24-volt power. FCC 1 W6USA- 20723-AL-E INDUSTRY CANADA 21325785A Surface Mount Technology (SMT). Fully programmable via built-in keypad (no costly exter- nal programmers necessary). Complies with NFPA 72-1993 edition (Local, Central Station and Remote Station [DACT only - not polarity reversal] Fire Alarm Systems). Reporting Formats include Ademco Contact ID and 14 others. Integral battery charger for up to 60 hours of standby power. Fuseless, power-limited technology meets new UL power- limiting requirements, effective May 1, 1995. Programmable Alarm Presignal Timer, Alarm Verifica- tion Timer and Optional Trouble Reminder. Single-person walk test with 256-event walk-test buffer. Fire drill function. Zone disable capability (software). 256-Event history bufferwith time and date stamp, stored in permanent memory. Accurate real-time clock/calendar. Electronics and operational controls fully enclosed in a lockable cabinet capable of housing up to 12 AH batter- ies. Optional LED-10 Series Remote Annunciators operate off serial two-wire EIA-485 interface. Optional contact-by-zone module and printer interface for on- or off-line printing. 230 VAC, 50 Hz international version available. ( D S624 (MS-52 lOUD, MS-52IOUDE) I 1 (9 CS68 (MS-521OUDC) This document is not intended to be used for installation purposes. We try to keep our I or anticipate all requirements. All specifications are subject to change without notice. Engineering and Manufacturing product information up-to-date and accurate. We cannot cover all specific applications ISO-9001 J For more information, contact Fire-Lite. Phone: (203) 484-7161 FAX: (203) 484.7118 Quality System Certified to p- L 12 Clintonville Road, Northiord, Connecticut 06472 international Standard ISO-9001 Made In the u.S.A. DF-51492 - Page lot i Remote Site Upload/Download The MS-5210UD may be downloaded or uploaded (re- quires panel software revision #MS52103. 0 or greater) with- out compromising the system fire protection at the pro- tected premises. Download system programming. Upload key system information: / Current system status, history + walk test files. /Zone, AC line, NACI, 2. 3 and 4, resettable power and battery voltages. / System programming. Upload or download within one minute without affecting normal fire panel functions. Multiple security techniques. Requires PK-5210UD programming kit, which works with most Hayes-compatible modems (consult factory for listing). Specifications Single PC board design using Surface Mount Technology (SMT). Two modular telephone jacks for connection to RJ31 XiModules. AC Power 120 VAC, 50/60 Hz, 2.3 amps. 230 VAC, 50 Hz, 1.2 amps (RE" suffix). Wire size: minimum 14 AWG with 600-volt insulation. Built-in brownout circuitry. Built-in voltmeter. Communicator One line-active indicator for each of two phone lines. "Kiss-Off' signal LED. Dual low telephone voltage detect" circuitry. Programmable event codes per each format. Up to 100 transmitted events/messages. Selectable/deselectable transmissions of 100 events. Communication Formats Express and Ademco Contact ID formats allow complete transaction to be communicated in under five seconds. Ademco Contact ID. 20 PPS, 3+1 standard and expanded. 20 PPS, 4+1 standard and expanded. 20 PPS, 4+2 standard and expanded. 4+1 and 4+2 Ademco Express. Initiating Device Circuits (zones) The MS-5210U0 includes ten programmable Class B Ini- tiating Device Circuits (zones). Use the CAC-10F Class A converter module to convert all Class B IDC'sINAC's to Class A. Each zone may support two-wire smoke detectors. Pro- gramming options include: Normally Open Contact devices (pull, heat). Four-wire smoke detectors. Waterfiow (silenceable/non-silenceable) operation. Supervisory (standard/auto-reset) operation. Remote switch for Reset, Drill, Silence, Acknowledge. Critical and Noncritical Process Monitoring (standard/ auto-reset). All circuits are power-limited and fully supervised. They allow up to 100 ohms of line resistance and allow for use of 12 to 18 AWG wire. Page 2ol3 - DF-51492 Notification Appliance Circuits Two Style Y (Class B) @ 3.0 amps each. Use the CAC- 1OF Class A Converter Module to convert all Class B NAC's and IDC's to Class A. Option module adds two Style Z (Class A) NACs © 1.5 amps each. All circuits are fully power-limited and meet the new UL power-limiting requirements effective May 1, 1995, us- ing fuseless technology. Auxiliary Outputs Resettable four-wire smoke detector power @ 500 mA. Non-resettable power @ 500 mA. Two fully programmable Form-NB relays. Option module adds two fully programmable Forth-C relays. Compatible Devices, EIA-485 Port LED-101M: ElA-485 Interface Module. Provides MS. 5210UD with ElA-485 output, capable of supporting up to 32 compatible ElA-485 devices (listed below). LED-1 0 Series: LED-type fire annunciators capable of displaying Alarm (red) and Trouble (yellow) LEDs for all ten Initiating Device Circuits (lDCs). NOTE: For Canadian Supervisory Service, use LED-I0LS2 only. AFM-I 6AF: LED-type fire annunciator capable of pro- viding up to 16 zones of Alarm (red) annunciation and com- mon system trouble LED. Mounts to 4-gang electrical box ONLY. LDM Series: Lamp Driver Module series for use with custom graphic annunciators. ACM-BRF: Remote Form-C relay module. Provides eight mappable Form-C relays driven by ElA-485 for contact-by- zone capability (two minimum required for contact-by-zone). Each requires ABS-BRF for mounting. NOTE: For more detailed information on Compatible EIA -485 Devices for use with the MS-5210U0, please refer to the LED- 10, AFM/AFM-X, LDM or ACM-8RF data sheets, document numbers DF-51500, DF-51465, DF-51384, and DF-5 1555 respec- tively. Cabinet Specifications The cabinet is red with a dark blue overlay. Knockouts on the top, sides, and back provide ease of wire entry. The cabinet can be surface or semi-flush mounted and is compact in design. Dimensions: Door. 17,11" high x 14.71" wide (43.46 cm high x 37.36 cm wide). Backbox: 16.90" high x 14.50" wide x 4.50" deep (42.93 cm high x 36.83 cm wide x 11.43 cm deep). Trim Ring: Part # TR-4-R, 20.020" high x 17.620" wide (50.85 cm high x 44.75 cm wide). PRODUCT LINE INFORMATION Model Description MS-5210UD Ten-zone, 24-volt Fire Alarm Control Com- municator (includes backbox, transformer, technical manual, and a frame & post op- erating instruction sheet). MS-52IOUDC Same as above with ULC listing and DP- 5210UD dress panel included. PRODUCT LINE INFORMATION, cont'd MS-52IOUDE Same as MS-5210UD with 230 VAC, 50 Hz transformer (UL listed). XRM-24 120 VAC, 100 VA transformer. Expands NAC power from 3.0 to 6.0 amps and sys- tem power from 3.6 amps to 6.6 amps. NAC-REM Notification Appliance (Signal) Circuit, Relay Expander Module. Adds two (Class A) NACs and two Form-C relays. CAC-10F Class Converter Module. Converts all Class B Initiating Device Circuits (zones) and stan- dard Notification Appliance Circuits to Class A / PRT.24 Printer Interface Module. Provides an EIA-232 printer output. Includes cable, DB9F and DB25 adapter. PK.5210UD Upload/download utility includes: program- ming software (3.5 IBM-compatible, high- density disks) and instruction manual. DP-5210UD Internal Dress Panel (included when order- ing MS-52IOUDC). MCBL-7 DACT phone cord, 7 feet long (two required). BB-17F UL listed battery backbox. Required for bat- teries over 12 AU. ABS-8RF Metal enclosure for mounting each ACM-BRF module. TR4-R Trim ring. PS-1270 Battery, 12 volt, 7.0 AH (two required). PS-12120 Battery, 12 volt, 12.0AH (two required). PS-12170 Battery, 12 volt, 17.0AH (two required, requires BB-17F backbox). UL LISTED RECEIVERS compatible with the MS-5210UD Format # (Addresses 16 & 42) Osborne RadIonics Sur. Silent in Hoffman 60001 Sescoa Guard Ademco Knight CS-4000 FBI Models 6500 3000R MLR-2 685 (1) 9000 (3) CP220FB 1&2 (5) (7) (9) o 4+1 Ademco Express V V V 1 4+2 Ademco Express V V V (8) V 2 3+1/Standard/1800i2300 V V (2) V V 4) V V(5,6) V V 3 3+1/Expanded/1800/2300 V V (2) V V (4) V V V 4 3+1/Standard/1900/1400 V V (2) V (4) V V V 5 3+1/Expanded/1900/1400 V V (2) V 4) V V V 6 4+1iStandard/1800300 V V (2) V V (4) V V (5) V V 7 4+1/Expanded/1800/2300 V V (2) V (4) V V V 8 4+1/Standardll900l1400 V V (2) V (4) V V V 9 4+1/Expanded/190011400 V V (2) V 4) V V V A 4+2lStandardl1800l2300 V V (2) V V 4) V V (5) V V B 4+2/Expanded/1800/2300 V V (2) V (4) V V V C 4+2/Standard/1900/1400 V V (2) V 4) V V V D 4+2/Expanded/1900/1400 V V (2) V (4) V V V E Ademco Contact ID V V V V KEY: (I) With 685-8 Line Card with Rev 4.4d software. With 9002 Line Card Rev 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-11 Line Card with Rev 2.6 software and a memory card with Rev 3.8 software. Model 6500 with Rev 600 software. Model 6000 with Rev 204 software. With Rev B control card at Rev 1.4 software and Rev C line card at Rev 1.5 software. Model 2 only. Version 1.62 software. DF-51492 - Page 3of 3 1/FTi\1 OFFICE OF THE STATE FIRE MARSHAL CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION c. FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:177 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Models MS521OUD fire alarm control unit. Power-limited; non-coded, local, remote station and central station service; manual, automatic, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: MS-5210UD Control Unit CAC-10F Class A Connector PRT-24 Printer Interface Module NAC-REM Bell/Relay Expander Module XRM-24 Transformer LED-10IM Annunciator Interface Module DP-5210UD Front Cover INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as a fire alarm control unit for use with separately listed electrically compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per *NFPA 72, 1996 Edition. Refer to manufacturer's Installation Manual for details. NOTE: For Alarm Verification Feature, the maximum Retard/Rest/Restart shall be adjusted to 30 seconds or less. Rev. 08-26-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 51 2000 Authorized By: Effective issue date to expiration date FL Listing Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager OPTIONAL ACCESSORIES The DS280 Series are low profile, Photoelectric System type smoke detectors. The patented chamber design provides superior immunity to false alarms caused by dust. Chamber CheckTM self diagnostics allow the sensitivity to be verified by simply looking at the detector LED. FEATURING ..... Direct Wire Design with Removable Terminal Strip Diagnostic/Sensitivity Test Features Chamber CheckTM Self Diagnostics Field Replaceable Smoke Chamber Easy Disassembly for Cleaning Sensitivity Voltage Output 12 or 24 VDC Operation 135°F/ 57°C Heat Sensor Option UL Listed, ULC Listed (E Detection Systems, Inc. The International Leaders of Intrusion, Fire and Sensor Products. 72 L DS280 7 - SPECIFICATIONS CHAMBER CHECK" SELF The Chamber Check automatic sensitivity test feature provides an indication if the detector is outside DIAGNOSTICS the factory calibrated specifications. This feature reduces service costs because the installer can easily determine which detectors require attention. This feature also reduces false alarms by alerting the end user that the detector is dirty, long before the possibility of producing a false alarm. A visual indication is provided in all DS smoke detectors. The DS284THR and DS284THSR include a trouble relay, allowing this indication to send a report to the central station. PATENTED CHAMBER DESIGN The detection chamber includes computer designed chamber walls and lenses to optimize internal light scattering and dust hiding capabilities. This provides for industry leading dust immunity without sacrificing detection. The detection chamber can be easily removed should it require cleaning and is field replaceable. Replacement chambers are available in packs of ten (10). VOLTAGE RANGE 8.5 to 33 VDC for 2 wire detectors. 10 to 30 VDC for 4 wire detectors. OPERATING TEMPERATURE RANGE +32° to +100°F! 0° to 40°C. 0 to 95% relative humidity (non-condensing). For UL Certificated Installations +32° to 100°FiO° to 40°C. RADIO FREQUENCY INTERFERENCE No alarm or setup on critical frequencies in the range of 26 to 950 Megahertz at 50 v/m. (RFI) IMMUNITY TEST FEATURES LED automatically flashes to indicate calibration trouble condition and latches on alarm. Sensitivity can be verified using visual check, magnet test or digital volt meter. ENCLOSURE DESIGN High impact, fire retardant ABS plastic enclosure and separate twist-lock mounting plate. The DS282 and DS284 detectors measure 2°1 5 cm High by 5"! 12.7 cm in Diameter. MOUNTING Separate mounting plate mounts directly to 4-inch octagonal electrical box, single gang box, and wiremold surface box #5738. A removable terminal strip allows for quick installation. SOUNDER 85 db Sounder activates on detector alarm or reverse polarity. Available on detectors with '5" in model number (see feature selection chart). TROUBLE RELAY Indicates Chamber Check trouble condition or loss of power. (DS284THR and DS284THSR only). OPTIONAL ACCESSORIES 'Replacement chamber ('Shipped in packages of 10) , EOL200 End-Of-Line Supervision module, TC2000 Test Cord, DT1 Removal/Test tool (suitable for testing only, not for installation/removal). LISTINGS UL Listing S3019, ULC -CBFP, CSFM #7272-1062:108, CE -EMC 89/336 U.S. PATENTS #5,400,014, #5,543,777, #5,552,765, #D359,078, #DES293,089 ORDERING INFORMATION Model Number 2-wlr& 4-wire 135° Ht Sensor ISouridér 85db Trouble Relay EOL Relay Auxiliary Relay Current Draw Standby Trouble Alarm DS282 2-wire 8OuA@ 12V. cauAmax 1uAmax Determined by panel DS282TH 2-wire • 80oA@12V. 100xAma, lODuAmax Determined by panel DS282THS 2-wire • 8OuA@ 12V. 1uAmax 100UAmx Determined by panel DS282THC 2-wire • 8jA@ 12V. luAmax ICOuAmaa Determined by panel D5284 4-wire ________ 80UA@2V. 1uAmax ImuAmax mAmax(.I- 5mA)@30V DS2B4TH 4-wire • 80.jA@12V. 1uAmax 1vAmau 1&nA max (.I- 5inA)@30V DS284THS 4-wire • 80uA@12V. 1aAmax imuAmax 78nAmax(x4- lanA)@30V DS284THR 4-wire • 18mAmax@30V 15mA max (.-A)@I2V 18MA max (./- 5mA)@30V DS284THSR 4-wire . . • 8mAmau@ 30 V 15n,Amax (.I-xA)@t2V 120mAma°(,/- lnA)@3OV DS284THCS 4-wire 80uA@ 12V. uma I OOuAmax 9canAmax(+I- 1erA)@30v DS284THC 4-wire • • 6jA @ 12V. 1uAma 1uAmax 33mA max (.1- i OmA)@3OV DS2B4THE 4-wire • 15mA 2mAmax ..5mA@12V 3nAmax(xl- 5mA)@30V DS284ES 4-wire . • . 15mA 2mA max +1.5.xA@t2V ImA)@ 30V DS2841S 4-wire Isolated . 1 2 nAmax(+I mA)@2V 1uAmau lmmAma.(.!- lnA)@3OV Detection Systems, Inc. UL 130 Perinton Parkway, Fairport, New York 14450-9199 ISO 9002 PIN 29668E (716) 223-4060' (800) 289-0096. Fax: (716) 223-9180 CERTIFICATE NO. 5137 73 JUL-06-2000 0937 DETECTION SYSTEMS 716 223 9180 P.02/02 OFFICE OF THE STATE FIRE MARSHAL. D FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM. LISTING SERVICE LISTING No. 7272-1062:108 Page 1 of 1 CATEGORY: Photoelectric Smoke Detectors USTEE: Detection Systems, Inc., 130 Perinton Parkway, Fairport, NY 14450 Contact: Frank Mioduszewski (71 6) 223-4060 DESIGN: Photoelectric type smoke detectors. Models are listed below: tS250, DS25QTH 0S282, DS2S2TH, DS2S2THS, DS282THC DS284, DS284TH, DS284THC', DS284T1-IR', DS284THS*, DS284THCS*, DS284THSR*, DS28415', DS284THE*, DS284ES*, DS284THES Model DS250TH, DS282TH and DS284THxx employ an integral 1350 fixed temperature heat detector. This heat sensor is intended for use Only a s a supplemental device to assist the smoke detector. Refer to Iistees data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdict i o n . MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL; Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control unit. Models D5250 and DS250TH are intended for use with separately listed bases model M2W, MB2WL, MB4 W , M84WA or MMWE. 'Rcv. 02-07-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire En g i n e e r i n g s t a f f h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the 11am listed. This listing should not be used to verify correct o p e r a t i o n a l r e q u i r e m e n t s o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable i n f o r m a t i o n s o u r c e s . Date Issued: JUNE 21, 2000 Authorized By: Effective issue date to expiration date Listing Expiresunc 30, 2001 BEN HO, Supervising Deputy Program Manager TOTAL P.02 Heat Detectors Series 600 The Heat Detectors Series 600 are supplied with the following Standard features: Rate-of-Rise and Fixed Temperature . Low Pmfile One or Two-Circuit, Normally Open Visual Indication Easy Installation • Operation Testing Description The Series 600 Heat Detector is attractive, durable and features combination rate-of-rise and fixed temperature operation. Heat detectors are available in 135°F and 200°F temperature ratings. Rate-of-rise detects heat by quickly responding to a rapid temperature increase. Rate-of-rise units have a wide spacing allowance of 50-foot centers. See specification table for details. Fixed temperature reacts to heat by responding to a specific temperature setting. Series 600 Detectors use the same reliable pneumatic rate-of- rise element of former models, but offer added aesthetic appeal. The pneumatic rate-of-rise element responds to a rapid rise in temperature, approximately 15°F. (8°C) per minute, by expansion of air within the sealed chamber faster than it can escape through a calibrated vent The resultant increase in pressure depresses the diaphragm, causing the electrical contact to close the circuit. The fixed temperature element uses a fusible alloy. When activated, the external heat collector drops away to provide quick visual confirmation that the element has operated. The units protrude only 1-3/8 inch from the ceiling surface with a junction box mounting. They have pleasing contours and an all-white finish that conforms to ceiling aesthetics. Installation Each detector includes a patented reversible mounting plate. In one position, it easily attaches to 4° square junction box, 3.25' or 4° octagonal box, or plaster ring. In reverse, the plate can be used for open wiring without a junction box A 114" space between detector and mounting surface allows for wire connections. All mounting screws are concealed. The detector attaches easily to the mounting plate with a push and twist motion. No tools are required. Junction Box Mounting Ceiling Surface Mounting J 1+8, 9 2-i 3-1/4" or 4 Cut for surface Reversible Octagonal Box or mounting_. Mounting Plate 4" Square Box 0 Reversible Mounting Jo Plate 82 8-32" Flat Round Head Head Screws Wood se to 1" Screws Mounting plate is molded of white self-extinguishing thermo- plastic rated at 221°F (105°C). The plate is extremely strong yet adapts to uneven mounting surfaces. Series 600 Testing Methods Models 601/621 and 602/622 can be tested by the quick application of heat from any convenient source. A portable hair dryer Is recommended. However, do not apply heat that exceeds the fixed temperature rating of the detector. Models 603/623 and 604/624 cannot be tested. However, the fusible alloy element used is considered so reliable that testing is not necessary, AR rights reserved (10/99). Model 601 and 621 Model 602 and 622 Model 603 and 623 Model 604 and 624 No Marking Gray Ring 0 Gray Spot Gray Ring and Dot Model 601 (1 circuit) 0 Model 602 (1 circuit) Model 602 (1 circuit) Model 604(1 circuit) Model 621 (dua circuit) Model 622 (dual circuit) Model 623 (dual circuit) Model 624 (dual circuit) Rate-of-Rise and Fixed Rate-of-Rise and Fixed Fixed Temperature only, Fixed Temperature only, Temperature, 135°F (57°C) Temperature, 200°F (94°C) 135°F (57°C) 200°F (94°C) Applications: Normal Applications: Normal tempe. Applications: Unusually violent Applications: Unusually violent temperature fluctuations rature fluctuations and ceiling temperature fluctuations temperature fluctuations and and ceiling temperatures temperatures exceeding 100°F and ceiling temperatures ceiling temperatures exceeding not exceeding 100°F (38°C) (38°C) but not 150°F (66°C) not exceeding 100°F (36°C) 100°F (38°C) but not 150°F (66°C) Maximum Spacing Maximum Spacing Maximum Spacing Maximum Spacing Allowance* - Allowance* - Allowance* - Allowance* - 50x50 ft. -UL 50x50 ft. -UL 25x25 ft. -UL 15x15ft-UL 30x30 ft. -FM 30x30 ft. -FM 20x20ft.-FM 'Refer to National Fife A/ann Code Standard NFPA 72 for application requirements Screw Terminals Standard Single Dual Circuit Detector Circuit Detector Used to send two independent signals. Wire from alarm Wire connected to panel or previous next detector or detector, end of line resistor. • U Wire from alarm nelorPreviotJs • Wire connected Wine connected to next detector to next detector or end of line or end of line resistor. NOTE: All single NOTE: All dual circuit models circuit models come come Mth one (2) normally with one (1) open dry contacts. noi'rnaily open dry contact. Important Special Notes Application: Heat detectors should be used for property protection. Reliance should not be placed on heat detectors for Life Safety. CAUTION: When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. Battery Back-Up: Heat detectors should be electronically supervised with battery back-up at the panel. The rate-of-rise mechanism may be subject to reduced sensitivity over time. Annual testing of the rate-of-rise mecha- nism is recommended. Electrical Ratings 6-125 VoltsA.C., 3.0 Amps. 6-28 Volts D.C., 1.0 Amps. 125 Volts D.C., 0.3 Amps. 250 Volts D.C., 0.1 Amps. Listings/Approvals Listed by Underwriters Laboratories (UL) Factory Mutual Approved (FM) California State Fire Marshal Approval (CSFM) City of New York (MEA) Listing No. 188-94-E Listed by Underwriters' Laboratories of Canada (ULC) This literature is provided for informational purposes only. CHEMETRONICS assumes no responsibility for the products suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or it you have a particular problem or question, contact CHEMETRONICS, Ashland, MA; Telephone (800) 496-8383. Chemetronics 400 Main Street Ashland, MA 01721 USA Phone: (800) 496-8383 Fax: (800) 496-7272 Website: wwwchernetronics.com All rights reserved (10/99). clJF0RttA DEPAMMENT FMESIRY & ARE PROTECTION OFflC€Oc TUE STA1 RilE MARSHAL FIRE ENG141EERNG BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING NO: 7270-0061t005 11 Pop l of I CATEGORY: Heat Detector USTEE Cherneirun. 4801 SouthwiCk Drivd. r Aoor Maneson, U. 60443 Contaci: Gary Xmbl.e (70) 283-4447 DESIGN. Models 601, 602w 603,604. 821. 822, 623 and (124 heat detectors Reler to Iisti(s date sheet iordetailed piOduct description and oier*tlónel coneldoreona. INSTALLATION: In accordance with listees ockfled installation instructions. apiceble codes and ordinances and in a manner acceptabls to the &-*o*y having jwisthction. MARKING: Lste&s name, model number, Ienpefatuie 08WV and UL label. APPROVAL- Listed as heat detectors for use with separately ftledcompatJoWe fire atatm corflroi units. The hsrnq 's based upon techmai dale sut,ml$od by the appkcant. CSFM Fee n9"has ;eviewed the lest rosultS ((fl) anO/or other data but rIces nnt make an cJenl rcation or any cl,rns This hJjn9 .5 ,',g &b lndorscmOfl% of ronmencat,cn of the 4wn ks*ed. This kshng should nOt be used to verily corvad oprIgl feQuIsemcrIs Ot wH.b0O - enleria Refer to b5100 daLi sh,pl. ,ncLa.on .nslruthons andtlw other su.iat$c mtormahnn soutce% Date Iss¼wd, JUNE 5, 2000 Autonzeri By I lrt(w i*,' rLth I$I4IftUI il.tr Listing Expires June 30, 2001_] BF HO. Program Manager November 15, 1999 F-050 (J Firelffee ALarms A PITTWAY COMPANY BG-12 Series Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices GENERAL The Fire-Lite BG-12 Series is a cost-effective, feature- packed, non-coded series of manual fire alarm pull sta- tions. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Seris fea- tures a variety of models including single- and dual-action versions. The BG-12 Series provides Fire-Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped. shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down posi- tion to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (lDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). Terminal numbers are molded into the backplate, elimi- nating the need for labels. U.S. PATENTS PENDING California State Fire Marshal 7150-0075:184 S711 Switch contacts are normally open. Can be surface (with SB-b) or semi-flush mounted. Semi-flush mount to a standard single-gang, double- gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the popular BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dustipaint cover in shape of pull station. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We Cannot cover all specific applications or ISO-9001 anhi:iOate all requirements. All specifications are subject to change without notice. For En -esri s". Manulacturin more information, contact Fire-Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 0ay System Certified to Flre-uTeALarrns One Fire-Lile Place. Norititord, Connecticut 06472 •,ancard!SO-9011I Male in TiC L SA DF52004 - 1ay' 1 of CONSTRUCTION PRODUCT LINE INFORMATION Cover, backplate and operation handle are all molded Model of durable polycarbonate material. BG-12s Cover features white lettering and trim. Red color matches System Sensor's popular BG - 12 SpectrAlertTM horn/strobe series. OPERATION BG-12L Description Single-action pull station with pigtail connec- tions, hex lock. Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. Same as BG-12 with key lock. The BG-12 manual pull stations provide a textured finger. hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking per- sons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bot- tom as a visible flag. Resetting the station is simple: in- sert the key or hex (model dependent), twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: BG-12 SB-b WP-10 Height. 5.500 inches 5.500 inches 6.000 inches (13.97 cm) (13.97 cm) (15.24 cm) Width' 4.121 inches 1 4.125 inches 4.690 inches (10.4673 cm) (10.4775 cm) (11.9126 cm) FDepth. 1.390 inches 1.375 riches 2.000 inches j (3.5306 cm) (3.4925 cm) (5.08 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or poiycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger." Stations shall be suitable for surface mounting on matching backbox SB-b; or semi- flush mounting on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. "NOTE: The words "FIRE/FUEGO" on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4' high; Pa 2 o 2 - DF.52004 BG-12LSP Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-12LWP Same as BG-12L with "outdoor use" listing. Includes WP-10 weatherproof backbox, and sealing gasket. FUTURE OFFERING - please contact the factory for availability. 1.390" (35.306) Wire Length Strip Gauge 7 1.000" (25.40) 0.750" (19.05) 5.500" (139.70) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION A OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:184 STArt 1IkE Page 1 of 1 CATEGORY: Manual Pull Stations/Boxes LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Hood (203) 484-1200 DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG- 12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG12LSP* and BG-12SP fire alarm pull boxes. The BG-1 2 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. XLF: 7150-0028:199 Rev. 03-06-2000 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 51 2000 Authorized By: Effective issue date to expiration date sting Expires June 30, 2001 BEN HO, Supervising Deputy IF-ul Program Manager Horn/Strobe with Standard Plate Strobe with Small Footprint Plate Horn with Standard Plate Features 24 volt strobe models: 15, 15/75, 75 and 110 candela • Universal mounting plate included with each unit 12 volt strobe models: 15 and 15/75 candela • One screw mounting of strobe and horn/strobe to mounting Horn models operate on 12 and 24 volts plate Low current draw: reductions as high as 45% • SpectrAlert strobe and horn/strobe take up zero room in the Two field selectable/reversible horn tones back box. - 3000 Hz Interrupted - Electromechanical Field selectable/reversible high-low dBA output on horn (low output on 24 volt models only) - 101 peak dBA @ 10 ft. high output" - 96 peak dBA @ 10 ft. low output" Field selectable/reversible temp 3 pattern or non-temp 3 continuous pattern on horn Horn/strobe can be wired either in tandem or independently Specifications Single gang mounting without the use of a mounting plate (horn model only) Self-contained screw covers Aesthetically pleasing design Synchronize horn and strobe with Sync•Circuit' module Silence horn on horn/strobe over a single pair of wires using Sync•Circuit module Sound output varies with tone and output options selected; sound levels based upon anechoic room measurements. Walk test: SpectrAlert horn/strobe and horn only work on "walk Mounting: 4" x 4" x 11/" or tests" with time durations of 4 seconds or greater. 2 x 4" x 1/s" standard boxes Input terminals: 12 to 18 AWG Indoor operating temperature: 320 to 120° F (00 to 49° C) Dimensions Weatherproof Strobe and horn/strobe operating temperature: 320 to 151° F (00 to 66° C) with universal plate: 5" x 5/8" x 2/16" Voltages: 12 or 24 VDC and FWR unfiltered Strobe and horn/strobe Operating voltage range*: 12 V, 10.5-17 V; 24 V, 20-30 V with small footprint plate: 33/8' x 5/8 x 2/16" Operating voltage range" (with Sync'Circuit module, MDL): 12 V, 11-17; 24 V, 21-30 V 5" x 51/8' , X 1'I6" / • These products should be operated within their rated voltage range; UI. does, however. lest functional integrity to -20% and + 10% of manufacturers stated ranges. 2/t6 x 55/t&" x 1 /16" 7.2 oz. 8.8 oz. (ü 6 17\ (I. ri> M F A 1 0 System Sensor 9/97 This document is not intended to be used for installation purposes. A05936-04 Horn with universal mounting plate: Horn without mounting plate: Weight, horn only: Weight, strobe and horn/strobe: General Description System Sensor SpectrAlert Series strobes, horns, and combination horn/ selectable features are accomplished with the use of pins and jumpers strobes are UL listed for primary signaling in life safety systems and meet located on the back of each SpectrAlert horn and horn/strobe. An accessory ADA public mode visible signaling requirements. module is not needed to make these field selections. The horn on horn/ SpectrAlert products can be connected to the alarm indicating circuit of strobe models will operate on a coded power supply. The horn only model a fire alarm control panel and are compatible with DC line supervision. The designed for coded power supplies (HCl2/24) wiU aLso operate on a coded SpectrAlert product line mounts to standard back boxes with the use of a power supply. universal mounting plate included with each unit. An optional small footprint mounting plate fits to a single gang box. An accessory back box The ADA compliant SpectrAlert strobes are electronic visible warning skirt gives a cosmetic finish to a 4' x 4' x 1'/? or a 2' x 4' x l/e' surface signals that flash at 1 Hz over their operating voltage range. These products mounted back box. All strobe and horn/strobe mounting options require are available in 24 volt models at 15, 15/75, 75 and 110 candela intensities only one screw attachment of product to plate. and in 12 volt models at 15 and 15/75 candela intensities. SpectrAlert These products are designed for 12 and 24 VDC and full wave rectified products feature dramatic reductions in current requirements. unfiltered power. Full wave rectified operation requires more current than DC operation. For detailed current draw information, consult the table . Sync-Orcuft Module below. The horn/strobe combination products are factory assembled with The Sync•Circuit Module is available for the synchronization of strobes and jumper wires for in-tandem operation. For independent wiring of horn and horns and can synchronize two Style Y (class B) circuits or one Style Z strobe, remove jumper wires. When wired for independent operation, the (class A) circuit. The module can also generate a synchronized temp 3 tone strobe will continue to run while the horn can be silenced. However, the for System Sensor's Multi-Alert" and PA400 horn products.' The strobe must be running for horn to operate. synchronization module allows the SpectrAlert horns on combination horn/ strobes to be silenced on 2-wire systems. SpectrAlert's Sync•Circuit Module Ho The SpectrAlert Series horns and horn/strobes provide two different field can be daisy chained for multiple zone synchronization. The Module shall not operate on a coded power supply. selectable/reversible tones, a high-low field selectable/reversible sound - output setting (low setting on 24 volt models only) and a field selectable/ 'For Multi-Alert and PA400: Strobes must be wired to a continuous source reversible temp 3 pattern or non-temporal continuous pattern. These field of power (non-coded power supply). SpectrAlert Current Draw Table Strobe Only Candela AVERAGE CURRENT (mA) 12V Modes J 10.5V 12V liv 20V 24V 30V oc I FWR DC I FWR DC I FWD DC I FWR DC I ewe oc I FWR 10.5V DC I ewe PEAK CURRENT (mA) 2V Models 4V Models 12V I 17V 20V 24V 30V oc I FWR DC ewe DC I FWR DC I FWR Oc I FWR IN RUSH CURRENT (mA) Z4V Modes l0.5V 12V liv 20V I 24V 30V DC FWa DC FiNP DC I FWR DC I ewe DC ewe oc I FWR 15 1331 1591 11411-57 811 1281 591 120 53 80 461 79 460 460 450 450 420 480 150 210 150 210 140 250 80 108 92 124 140 190 110 230 220 280 270 370 15175 168 182 142 171 99 150 76 92 66 93 58 132 490 ..L20 490 520 460 480 170 270 170 270 160 270 76 104 88 126 160 185 170 230 210 270 270 360 75 NA NA NA NA NA I NA 1 145 110 123 1591 1021 141 NA NA NA NA NA NA 350 440 340 460 330 480 NA NA NA NA NA NA 190 240 230 280 290 380 110 NA NA NA NA NA NA 169 220 140 191 1151 174 NA NA NA NA NA NA 460 56014501570[ 420 620 NA NA I NA NA NA I NA 1 190 1230 220 2WT-----nnl 370 Horn Only High/Low Temp Tone Volume /Non AVERAGE CURRENT 10.5V 12V 17 0V DC ewe DC FWR DC (mA) 24V Models I 24V I 30V FWR DC rwej DC PeP Electro- High Temp mech. Non 10 II 10 1(1 14 21 25 29 26 10 16 10 19 l2lModels JNAI 14 29 23 30 4 Low Temp NA NA NA NA NA 121 13J 17 NA NA NA NA 1 Non NA Hz High Temp Non Temp ii 13 2 3000 11 11 16 _!.1 17 33 Interrupt. 11 21 14 a2823 NA NA NA 4 Low NA NA NA 14 NA NA NANA 1 Non NA NA 13 2 Horn/Strobe -15 cd High/Low Temp Tone Volume /Non AVERAGE CURRENT (mA) 24V Models 10.SV I 12V 17V 20V I 24V 30V DC I FWR DC I FWR DC FwR DC I FWR DC FWR DC I Pwe Electro- High Temp meth. Non 143 1701 1241 157 95 142 781 1011 78 98 75 141 143 170 1241 167 95 142 691 981 76 tOO 76 138 Low Temp Non NA NA NA NA NA NA 70 92 66 93 63 1 NA NA NA NA NA NA 71 92 67 93 63 1321 3000 Hz High Temp Interrupt Non Low Temp 144 172 125 1681 97 144 5.3 106 81 103 144 173 125 168F95 146 78 102 80 106 81 NA NA NA NA NA NA 73 94 70 95 83 gI NA NA NA NA 67 Non NA NA 72 92 69 94 68 Horn/Strobe — 15/75 Cd High/Low Temp Tone Volume /Non AVERAGE CURRENT (mA) i2IJModels I 24V Models 10.5V 12V 17V I 20V I 24V 30V DC ewe oc ewe oc FWR DC I Pe RIOC I FWR DC I PeR Electm- High TemD mech. Non 1781 193 152 181 1131 1641 95 113 9111111 87 153 178 193 152 16' 1131 1641 93 110 891 1131 88 150 Low Temp Non NA NA NA NA NA I NA 87 104 791 1061 75 14 NA NA NA NA NA NA 88 104 80 106 High Non 179 195 152 183 iic 166 100 118 94 116 j6 75 d14 3000Hz 95 Interrupt i? L53 117 168 95 114 93 119 jg NA NA NA 93 Low NA NA NA 90 106 83 108 NA NP NP NP 79 Non NP NA 89 104 82 107 80 Horn/Strobe -75 Cd High/Low Temp Tone Volume /Non AVERAGE CURRENT (mA) 24V Models lO.SV 12V 17V 20V A 24V 30V DC FWR DC FWR DC FWR DC FWDC] FWR DC I FWR Electro- High Temp mech. Non Low jemp Non NA NA NA NA NA I NA 164 1911 !4]!? 131 167 NA NA NA NA NA NA 163 1981146 169 132 169 NANANANANANAI5618213J162l19156 NA NA NA NA NA NA 157 182 137 162 119 157 3000Hz High TempNA Interrupt. Non NA NA NA NA NA 169 1961151 172 139 174 NA NA NA NA NA NA 164 192 150 175 137 177 Low Temp Non NA NA I NA NA NA NA 159 194 140 164 123 160 NA NA TTF NA NA NA NA 158 1881 139 163 124 162 Horn/Strobe — 110 Cd High/Low Temp Tone Volume /Non AVERAGE CURRENT (mA) 12V Mode 24Y1&lsla 10.5v 12V liv 20V 24V 30V DC FWR Dc I FWA DC I FWR DC FWFt DC FWR DC PAR Electro- High TeM2 mech. Non NA NA I NA NA NA NA 188 241 165 20911441200 NA NA NA NA NA 23 163 211 14 202 Low gNANANANANANA231532O4i32j.fl9 Non NANANANANANA2I 154 3000 Hz High I!fl Interrupt Non NA NA NA NA NA NA NA r186 NA 24 168 214 152 NA NA NA NA 24 7 .4j.32J 2O7 50 Low NA NA NANANANANANA234j7)6138 Non NA NA NA 232 156 205 13 Page 2 This document is not intended to be used for installation purposes. AOS-936-04 Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4° x 4° x V/i" back box or a single gang 2" x 4° x 1/i" back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert products, when used in conjunction with the accessory Sync'Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 10.5 - 17 volts. 24 volt rated devices shall have an operating voltage range of 20 - 30 volts. SpectrAlert products shall have an operating temperature of 32 to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Horn Horn shall be a System Sensor SpectrAlert model _________ capable of operating at 12 and 24 volts. Horn shall be listed to UL 464 for fire protective signaling systems. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. The horn only model designed for coded power supplies (HCl2/24) shall operate on a coded power supply. Strobe Strobe shall be a System Sensor SpectrAlert model _________ listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/strobe shall be a System Sensor SpectrAlert model listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over its entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Module Module shall be a System Sensor Sync.Circuit model _________ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal 3. Also, the module shall silence the horns on horn/strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 4/6" x 4/16 x 21/" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The Module shall not operate on a coded power supply. SpectrAlert Dimensions -1 __215/16__._I 5116w - t2 Horn/Strobe with Small Footprint Mounting Plate Horn Only (same dimensions for strobe only) 5j14- 5" orn/Strobe with Universal Mounting Plate (same dimensions for strobe only) Sync. Circuit Module H Page 3 This document is not intended to be used for installation purposes. A05-936-04 SpectrAlert Mounting Diagrams Horn Direct Mount Horn Surface Mount with Accessory Back Box Skirt - Horn with Universal Mounting Plate (included with each product) Strobe or Horn/Strobe with Accessory Small Footprint Mounting Plate Strobe or Horn/Strobe with Universal Mounting Plate (Included with each product) x x 2'h" back box 101- 4iIi Strobe or Horn/Strobe Surface Mount with Accessory Back Box Skirt Sync.Clrcult Module Direct Mount Page 4 This document is not intended to be used for installation purposes. A05-936-04 TO NEXT DEVICE OR EOL FACTO JUMPS Mcrnnnnun l 4 TO NEXT VI HORNOII{ H EOL <UI NOW: SToneD UT U SOwONDTrnOUM.T DSO.SRU1. N TO NEXT FRO {< FACP. MODULE ETWISS OR EeL < S * V 4 ,U.onOUIZ OR PREVIOUS DEVICE 'S — bnonUwd. I...frw. D050TSa SpectrAlert Wiring Diagrams TANDEM OPERATION INDEPENDENT OPERATION HORNISTROBE COMBO HoHos HORN AND STROBE (+) R It HORN HOR1RO8E OBEOY N 101 FOUR WIRE SYSTEM :c : COMBO MODELS ANY lIE OF MODELS . OPERATION - [}( WIRED F TWO WIRE SYSTEM 0 • WIRED R INDEPENDENTINDEPENDENT OR TANDEM _______ :8 (HORN CAN BE TURNED OFF OPERATiON 0 • AT THE PANEL WHILE STROBES J MTR ___________ (.) CONTNJE TO OPERATE) Horns Silenced Over Two-Wire Circuit Temp 3 Coding of Multi-Alert and Any mix of Horn/ Strobes or Strobe only devices is acceptable PA400 Sounders Horn control connects to interruptible power source Note: Strobes must be powered from non-coded Supply MODULE I FACP #1 MODULE I }nos TO NEXT SPECTRALERT o'I CAd 1}r' rons.{R DEVICE OR EOL FACP - oj { ... NEXT DEVICE OR > — NACI EOL NAC2 - TYPES OF -o 0— SPECTRALERT DEVICESI HORN ONLY HORHISTROBE STROBE ONLY - - — 0 { TO NEXT - DEVICE OR TS_ awnlfi OFF EOL c,__OUTS1g MODULE 2 Ho,, will be T..opor FACPIZ I COddSndIflnYflS. TEDOF. JUMPER ON '_ NEXT P TO FIT t DEVICE OR EOL NACI _o} -a NAC2 I RO I-I.E ->-1 - TO NEXT HORN ONLY DEVICE OR OOT•j.-. EOL _ TOJJ Al .oOANF* hoI.. a OFF Sod 0000 Oil OpFOI 5*5)00. NOTE, I) Any mm of SponOAmod Solo .00b.. .000. only. OF FIOFI*o.,ly 0.540... .800001* to, 0000 1. 2) N. donlo.. or horn only em. .Ilow.d on ono 2.11 no 0.030.. 5,. In.t0000 on on.,. 2. onn.ln.i. EOL ,n.beIoF St Son. oonooI rrnln*I. Sound Output Guide (dBA) UL Reverberant Room dBA@ volts DC Anochoic Room Peak dBA @10 ft./volts DC 11Z 12 2Q M N 112li ZQ 21 32 Temporal Low Tone Electromechanical NA NA NA 75 75 79 NA NA NA 94 96 98 3000 Hz Interrupted NA NA NA 75 79 79 NA NA NA 94 96 98 High Tone Electromechanical 75 75 79 82 82 82 94 95 98 100 101 102 3000 Hz Interrupted 75 75 79 82 85 85 94 95 98 100 101 102 Non- Low Tone Electromechanical NA NA NA 79 82 85 NA NA NA 94 96 98 Temporal 3000 Hz Interrupted NA NA NA 82 82 85 NA NA NA 94 96 98 High Tone Electromechanical 79 79 85 85 88 88 94 95 98 100 101 102 3000 Hz Interrupted 79 82 85 88 88 88 93 95 98 100 101 102 Page 5 This document is not intended to be used for installation purposes. A05-936-04 SpectrAlert Ordering Information All weatherproof models use weatherproof back box model WBB. Avg. mA Avg. TM - Red White Voltage Candela @ Nom. VDC @ Nom. FWR 40rn/Sbobe$ P1215 P1215W 12 15 124 167 P121575 P121575W 12 15/75 152 181 P2415 P2415W 24 15 78 98 P241575 P241575W 24 15/75 91 m P2475 P2475W 24 75 148 167 P24110 P24110W 24 110 165 209 P241575K (weatherproof) - 24 15/75 91 111 P2475K (weatherproof) - 24 75 148 167 P24110K (weatherproof) - 24 110 165 209 Canada P2415A P2415WA 24 15 78 98 P241575A P241575WA 24 15/75 91 111 P2475A P2475WA 24 75 148 167 P24110A P24110WA 24 110 165 207 P241575KA (weatherproof) - 24 15/75 91 111 P2475KA (weatherproof) - - 24 75 148 167 P24II0KA (weatherproof) - 24 110 165 207 Latin America P241575F (FUEGO) 24 15/75 91 111 Strobes S1215 S1215W 12 15 114 151 S121575 S121575W 12 15/75 142 171 52415 S2415W 24 15 53 80 5241575 S241575W 24 15/75 66 93 52475 S2475W 24 75 123 159 S24110 S24110W 24 110 140 191 S241575K (weatherproof) - 24 15/75 66 93 S2475K (weatherproof) - 24 75 123 159 524110K (weatherproof) - 24 110 140 191 Canada S2415A S2415WA 24 15 53 80 S241575A S241575WA 24 15/75 66 93 S2475A S2475WA 24 75 123 149 S24110A S24110WA 24 110 140 191 S241575KA (weatherproof) - 24 15/75 66 93 S2475KA (weatherproof) - 24 75 123 149 524110KA (weatherproof) - 24 110 140 191 Latin America S241575F (FUEGO) 24 15/75 66 93 Horns H12/24 H12/24W 12/24 NA 12/23 12/21 H12/24K (weatherproof) - 12/24 NA 12/23 12/21 HC12/24 (for coded power) HC12/24W (for coded power) 12/24 NA 12 /23 12 /21 HC12/24K (for coded power, weatherproof) - 12/24 NA 12 /23 12/21 Canada H12/24A H12/24WA 12/24 NA 12/23 12/21 H12/24KA (weatherproof) - 12/24 NA 12 /23 12 /21 HCl2/24A (for coded power) HC12/24WA (for coded power) 12/24 NA 12 /23 12/21 Sync.Clrcult Module MDL MDLW 12/24 NA 16 24 Canada MDLA MDLWA 12/24 NA 16 24 Small Footprint MountIng Plate for Single Gang Only S-MP S-MPW NA NA NA NA Surface Mount Back Box 51drt BBS BBSW NA NA NA NA Universal Mounting Plate (replacement) D-MP D-MPW NA NA NA NA Weatherproof Back Box WBB - - NA NA NA NA Notes: Agency Listings - Indoor models: UL ULC. FM, CSFM, MEA. Weatherproof models: UL, all others pending. Horn for coded power: UL, ULC, FM, CSFM, MEA. All SpectrAlert products are designed for wall mount only. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADA.AG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/strobes are recommended for 20' x 20' rooms or less. Horn and horn/strobe current draws assume horn is set at temp 3. electromechanical tone and high audibility. - FWR - Full Wave Rectified SystemSensor WorldwideManufacturing&Distribution In Canada: In the Far East: In Italy: In the United Kingdom: Telephone: 905-812-0767 Telephone: 852.2191-9003 Telephone: 39-40-9490-111 Telephone: 44-1403-276500 i'x: 905-812-0771 Fax: 852-2736-6580 Fax: 3940-382137 Fax: 44-1403-276501 In China: In India: In Singapore: Telephone: 852-2191-9003 Telefax: 91-022-8202564 Telephone: 65-273-2230 Fax: 852-2736-6580 Fax: 65-273-2610 Page 6 This document is not intended to be used for installation purposes. A05-936-04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: USTEE: 7135-1209:173 Audible Devices System Sensor, 3825 Ohio Ave, St Charles IL 80174 Contact: Andrej Nikolic (630) 377-6674 Page 1 of 1 DESIGN: Models P1215, P121575, P2415, P241575, P2430, P2460, P2475, P2495 and P24110 horn/strobes with or without suffix -w (white color) and suffix F for FUEGO design, suffix AG for AGENT and suffix EV for EVAC. Suffix -F, -EV and -AG are available for all models. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: -12: 10.5- 17 VDC -24: 20- 30 VDC Candela: -15: lbcd -1575: 15cd, 75cd on axis -30: 30cd. -60: 60cd -95: 96cd -75: 76cd -110: llOcd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for field assembly. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired application. For wall mount and Indoor use only. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition. Refer to manufacturer's Installation Manual for details. NOTE: Models P1215 and P121575 are NOT intended for Public Mode Fire Alarm Service when used on 12 V control panel at low volume. Rev. 03-26-99 / This listing Is based upon technical data submitted by the applicant CSFM Fire Engeieering staff has reviewed the test results I and/or other data but does not mace an Independent verification of any claims. This listing Is not an endorsement or 1 recommendation of the item listed. This hsting should not be used to verify correct operational requirements or instalation criteria. Refer to listee's data sheet, kstaIlation instructions and/or other suitable iriforrnation sources. Date Issued: JUNE 5, 2000 Authorized By: Effective issue date to expiration date g June 1 BEN HO, Supervising Deputy Program Manager VSR-F VANE TYPE WATERFLOW P OTT Fit ALARM SWITCH WITH RETARD Potter Electric Signal Company Potter Electric Signal & Mfg., LTD. 2081 Craig Road • St. Louis, MO 63146-4161 55 Glen Cameron Road (314) 878-4321 (800) 325-3936 Thornhill, Ontario, Canada 131 1P2 www.pottersignal.com (905) 882-1833 U.S. PAT. NO. 3921989 CANADIAN PAT. NO. 1009680 OTHERS PATENTS PENDING GENERAL INFORMATION The Model VSR-F is a vane type watertlow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe, schedules 10 through 40. sizes 2" thru 8". LPC approved sizes are 2' thru B" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted Service Pressure: Up to 450 PSI Minimum Flow Rate forAlarm: 10 GPM MaximumSurge: 18FPS Contact Ratings: Two setsof SPDT (Form C) 15.oAmpsat 125/250VAC 2.0Ampsat 3OVDC Resistive Conduit Entrances: Two knockouts provided for l/2" conduit Environmental Specifications: Suitable for indoororoutdooruse with factory insta [led gasket anddie-casthousing. NEMA4/IP54 Rated Enclosure- usewith appropriateconduit fitting Temperature Range: 40F/1 20"F, 4.5C/49C Non-corrosivesleevefactoryinstalled in saddle Caution: This device is notintended forapplicationsi n explosive environments SizesAvailable: Steel Pipe schedules 10 thru 40, sizes 2 thru8" BS 1387 pipe 50mm thru 200mm Note: Forcopper orplastic pipe use Model VSR-CF ServiceUse: Automatic Sprinkler NFPA-13 One ortwofamilydwelling NFPA-130 Residential occupancy uptofourstories NFPA-13R National FireAlarm Code NFPA-72 Optional: CoverTamperSwitch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the waterfiow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 11/4" + 118" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. PRINTED IN USA MKT. #8800001 - REV N PAGE 1 OF 2 MFG. #5400761 - 6/98 FIG. 4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. (E)POTTER VSR-F VANE TYPE WATERFLOW SWITCH WITH RETARD FIG. I FIG. 2 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL 41,11, cp DWD. #92-3 RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS, A 8 SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO B. DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion of the connection in the event that the wire becomes dislodged from under the terminal. TO INSTALL, DRILL A HOLE AS INDICATED: PIPE SIZE HOLE SIZE 2' to 2 1/2' 11/4'+1/8"-1116* (50mm to 65mm) (33mm ±2mm) 3'to8' 2'±l/B' (80mm to 200mm) I (50mm ±2mm) DWG. #761-30 DIRECTION WATERFLOW FIG. 3 TYPICAL ELECTRICAL CONNECTIONS LOCAL BELL TRANS'ORMER CLASS B (STYLE B) OR BATTERY POWERED END—Or—LINE RESISTOR CKT. (SEE NOTE) COM. COM. OPEN ON ALARM / CLOSE ON ALARM OPEN ON ON ' I N o / tCLOSE ALARM J M RE! ___('__] N.C. N.O. SIGNALING DEVICE SUPVISEO LOOP (SEE NOTE) COM. TYPICAL SWITCH ACTION OPEN ON V CLOSE ON TO COM. FROM ALARM ALARM DE OPEN ON I' / CLOSE ON CONTROL J o ALARM '1-' ALARM J4 _____ PANEL N. . N.C. TO N.O. N.C. _____ DV NOTES: The Model VSR-F has two switches. one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. For supervised circuits see 'Switch Terminal Connections' drawing and caution note (Fig. 1). TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV N PAGE 2 OF 2 MFG. #5400761-6/98 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STA11JIRE MAMMAL LISTING No. CATEGORY: LISTEE DESIGN INSTALLATION: MARKING: 7770-0328:001 Page of 1 Valves/Switches Potter, 2081 Craig Road, St. Louis, MO 63146 Contact: Brad Serangeli (314) 878-4321 Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed 'product description and operational considerations. Vane Types VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS-SR VS-F VSR-SFG VSR-SFT VSG VSR Pressure Type- WFS-13 WFSR-C WFSPD-B PS-10A PS-100A WFSR-F In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL or FM label APPROVAL. Listed as waterflow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1 /2", 3"). Model VSR-SF for use on 1", 1-1/4" and 1-1/2" steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4" and 1-1/2" plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2", 4", 5", 6", 8" and 10" pipe. Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 40°F. 'Rev. 06-05-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation t '"i criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 5, 2000 Authorized By: Effective issue date to expiration date JF7Li;tingExpires June 30, 2001 / BEN YSupervising Deputy Program Manager ®®POTTER OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH Mona Potter Electric Signal Company Potter Electric Signal & Mfg.- LTD 2081 Craig Rd., I P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146-4161 Don Mills, Ontario, Canada M302M3 (314) 878-4321 1 (BOO) 325-3936 (416) 441-1833 UL & CSFM LISTED, FM, APPROVED, & NYMEA ACCEPTED Dimensions: 6.19"L X 2.25"W X 5.88"H 15.7cm. L X 5.7cm. W X 14.6cm. H Weight: 2 lbs. /.9 kg. Enclosure: Cover - Die Cast Aluminum Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1----One set of S.P.D.T. (Form C) OSYSU-2—Two sets of S.P.D.T. (Form C) 15.00A. © 125/250VAC 2.50A @ 0-30VDC resistive Environmental Limitations: -40rF to+14O°F(-4OC to60C) NEMA 4 & NEMA 6P Enclosure. Indoor or Outdoor Use (Not for use in hazardous locations, See Bulletin 415400705 OSYS-U-EX for hazardous locations). Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: AUtomatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 OSYSU-1 STK. NO. 1010106 OSYSU-2 STK. NO. 1010206 GENERAL INFORMATION: The OSYSU is used to monitor the open position of an OS & Y (outside screw & yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of S.P.D.T. (Form C) contacts and the OSYSU-2, containing two sets of S.P.D.T. (Form C) contacts. These switches mount conveniently to most OS & Y valves rang- ing in size from 2" to 12". They will mount on some valves as small as 1/2". The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be clt with the building owner or responsible party. Replacement or additional cover screws and hex keys are available. See ordering information on page 4. OPTIONAL COVER TAMPER SWITCH: A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING: The OSYSU and its associated pro- tective monitoring system should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). PRINTED IN USA MKT. 18820004 - REV E rAGE I OF 4 MFG. 115400979 - 6194 OSYSU-1, -2 PO ER - OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 1 SMALL VALVE INSTALLATION - 112" THRU 2 112" SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. T H E Y W I L L M O U N T O N S O M E VALVES AS SMALL AS 112". J-HOOKS MAY BE REQUIRED ON VALVES WITH LI M I T E D C L E A R A N C E . CLAMP BAR CARRIAGE BI SLOTTED MOUNTING HOLES MAY BE USED FUR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. 0979-3 SMALL VALVE INSTALLATION Remove and discard "C washer and roller from the trip rod. 6. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Remove the OSYSU. File a 1/8" deep groove centered on the mark on the valve stem utilizing a 3116" diameter straight file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve Is operated. Loosen the locking screw that holds the trip rod In place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that It contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) Inch long notched section (ee Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to Insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE 1 HAT TilE STEM THREADS DO NOT ACTIVATE THE SWI1CIl. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COUIJ RESULT IN A FALSE VALVE OPEN INDICATION. ---- -- PRINTED IN USA MKT. N8820004 - REV E PAGE 2 OF 4 MFG. 05400979- 6/94 OSYSU-1, -2 (P)POTrER OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" SIZES 3' THRU 12' VALVES USE CARRIAGE BRACKET BOLTS. CARRIAGE BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS (2 REQUIRED) SLOTTED MOUNTING HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF S\./ITCH ON BRACKET. YOKE VALVE STEM TRIP ROD GLAND DWG- 11979-4 LARGE VALVE INSTALLATION With the valve In the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod In place and adjust the rod length (see Fig. 4). When adjusted properly,. the rod should extend past the valve screw, but not so tar that It contacts the clamp bar. Tighten the locking screw to hold the trip rod In place. IJ_OJ_i If trip rod length Is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break oil the one (1) inch long nolched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mark the valve stem at the center of the trip rod. . Remove the OSYSU. File a 118 deep groove centered on the mark of the valve stem utilizing a 3I8 diameter straight file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Tighten the adjustment screws and mounting Imrdwate. Check to Insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A EALE.YALVE_OPEN INDICATION. PRiNt EL) IN USA MKT. 8620004 - REV E PAGE 3 OF 4 MFG. #5400979 - 6194 MEW :nrw 9-6 POD TYPICAL ELECTRICAL CONNECTIONS beN. CIRCUIT N.D. 10 POWER ron CO' NC. INOCAIIIt DEVICE elOICAUNC DEVICE 10 surERVISORY CIRCUIT L M or No OF CONTROL PA4M UNE COM. NC. 8151510R U*C. j079-I Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION CLOSED VALVE POSItION CON. Sw it CON. N 0 SW 111 COM.L4,N.D. SW 12 CON'FN. SW 17 FIG. 4 KN ro CO PARTS OSYSU-19 -2 ..(E)PO ER OUTSIDE SCREW AND YOK' VALVE SUPERVISORY SWITCH FIG.3 DIMENSIONS 6.19 4.75 3.62 --..T 3 L409 0 c:Qi_. -r ___ t ROD RETRACTED .99 AND BREN(AVAT 3(18 SECTION REMOVED I36 I rthl r I I II 1 I I I I I I I ROD EXTENDED Li.,.; DVG. e979-5 FIG. 5 BREAKING EXCESSIVE ROD LENGTH DWG. -0979-7 ORDERING INFORMATION MPD.I. PEflIfJlQN JKJIQ. OSYSIJ-I OrlisidS Screw & Yoke -Supervisory Switch (Single switch) 1010106 0SYSIJ-2 outside Screw & Yoke•SupeMsory Switch (Double switch) 1010206 -- Cover Screw 5490293 -. I lox Kay for Cover Screws and Installation Atflustments 5250062 -- Optional Cover Temper Switch Kit 0090131 For pressure reducer type valve Inatallallon kits (II required) contact velve manufacturer. DWG. 11979-2 - PRIN LED IN% USA MKT. 16820004- REV E PAGE 4 OF 4 MFG. 15400979 - 6/94 pago of •i CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7770-0328:010 CATEGORY Valves/Switches LISTEE Potter, 2081 Craig Rd., St. Louis MO 63146 Contact: Brad Serangeli (314) 878-4321 DESIGN Supervisory switches listed below to monitor pressure, OS&Y, gate. qlobe.!qate. PIV, tank temperature or water level valves. Refer tolistee's data sheet for detailed product description and operational considerations. HIS-B WLS-W WLS-S PS-40A PS-120A OSYSIJ-2 OSYS-B PMS PTS-B OSYSU-1 GVS PCVS-1 PIVS-B TTS-S TTS-W PCVS-2 wt.s Prs-c INSTALLATION In accordance with listees printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, model designation and FM or UL label APPROVAL Listed as sprinkler system supervisory switches NOTE: Formerly 7738-0328:010 - flev.0531-20C) This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering stall has revir,wod lhr tel r'';ullc and/or other data but does not make an Independent verification of any claims. This listing is not an nml'rreit,Qnt 'r recommendation of the Item listed. This listing should not be used to verify correct operational roqnirenicnts or in -.1-11I.-Itivil j•(. - - tj criteria. Refer to flstee's data sheet. Installation Instructions and/or other suitable information 'ources. Date Issued: JUNE 12, 2000 Authorized By: Effective issue date to expiration date (~~Www_ [ Listing Expires June 30, 2001 1 BEN HO, Supervising Deputy Program Manager