Loading...
HomeMy WebLinkAbout3242 CANDELAS ST; ; FPR2017-0255; PermitI 1 I I 1:11 ']4I (äty of Carlsbad Print Date: 05/19/2022 Job Address: 3242 CANDELAS ST, CARLSBAD, CA Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2017-0255 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 06/22/2017 Issued: 08/22/2017 DEV2016-0060 Finaled Close Out: 03/25/2021 Final Inspection: INSPECTOR: Fieri, Dominic Workman, Carisa Project Title: CYPRESS AT THE PRESERVE Description: CYPRESS AT THE PRESERVE / MODEL / PLAN 2XA - SPRIKLER /LOT 26 FPContractor: NP MECHANICAL INC P0 BOX 309 CORONA, CA 92878-0309 (951) 667-4220 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov No. 170 to2.5 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Carlsbad Senior Housing SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 5592 El Camino Real CITY: Carlsbad PHONE:( 714) 557- FAX NUMBER: (714) 486-3994 Largest Building (ft.2): 84,243 Sprinkled? YES Construction Type V-A SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Cougar Drive at Palmer Way TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 107 PSI Hydrant Number (if applicable):H56 Elevation of test: 243 Feet Main Size: 12 INCH Pressure Zone: 490 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3,800 GPM Residual Pressure 109 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 3,800 gpm. There was no specific request for fire flow from the Client or Fire Department. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name:jn*,f. Mael, P. E. Signat Title/O Manager Eng. Lic. No. (if applicable): C69606 Date: 11/07/2018 III 1 Foxtail Loop 490/375 PRS 10" L Project Site N Legend 0 w_Hydrant Pipe ZONE ) Fire Flow Test -375 Location H56 430 0. 490 I / 550 C — B0 I /0 0 8" 12 0 EID 8" ________ rn O B" 0 PRIVATE RD #170 Carlbad Senior Housing - Fire Flow Analysis J MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS AT THE PRESERVE Building : PLAN 2X Location CALC AREA 1 System : 1 Contract Data File : PLAN2X CAl 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page CYPRESS ATTHE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - CALC AREA 1 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9!_0T OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S ( )Other T ( )Specific Ruling Made by Date E N Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 26.204 Psi Required 36.346 At BR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 94 Elev. R Residual (Psi) - 66 Other Well Flow (Gpm) - 3750 Proof Flow Gpm S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical Page 2 CYPRESS AT THE PRESERVE Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 12.127 C2 - Residual Pressure: 59.4 D2 - System Flow :26.204 C2 - Residual Flow : 3750 D2 - System Pressure : 65.318 Hose ( Demand) : 5 D3 - System Demand : 31.204 Safety Margin : 19.281 150 140 130 p120 R 11 E10° 90 C1 92 S 80 U 70 R 60D3 - C2 E5° 40 30 20 10 I 01 ILISS.I I I I 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N 1 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 1 1/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD NP Mechanical CYPRESS AT THE PRESERVE Page 4 Date 5/25/17 Node No. Elevation K-Fact Pt Actual Pn Flow Density Actual Area Press Req. Hi 9.0 4.9 7.04 na 13.0 0.05 256 7.039 H2 9.0 4.9 7.26 na 13.2 0.05 256 7.0 H3 19.0 12.87 na H4 19.0 14.7 na H5 19.0 15.65 na H6 29.0 12.07 na H7 29.0 12.15 na Dl 10.0 7.36 na D2 10.0 7.22 na 10.0 8.17 na 2 10.0 11.25 na 3 20.0 11.41 na D3 20.0 12.44 na 4 20.0 12.44 na 5 20.0 13.16 na 04 20.0 14.27 na 6 20.0 14.27 na D5 20.0 15.22 na 7 20.0 15.59 na 8 20.0 15.72 na 15 30.0 11.59 na D6 30.0 11.64 na 16 30.0 11.68 na D7 30.0 11.71 na 17 30.0 11.71 na 18 30.0 11.77 na 19 30.0 11.73 na 20 30.0 11.86 na 9 20.0 15.9 na 10 20.0 16.34 na 11 20.0 16.57 na 12 20.0 17.53 na 13 20.0 15.27 na 14 20.0 11.61 na 21 10.0 23.77 na 22 10.0 25.09 na TR 10.0 26.9 na BR 2.0 36.35 na 5.0 X 2.0 37.43 na EL -3.0 40.02 na Ml -3.0 45.58 na M2 -3.0 49.8 na CM -3.0 58.38 na 100 -3.0 58.38 na 101 -3.0 58.39 na 102 -3.0 58.39 na 103 -3.0 58.39 na 104 -3.0 58.38 na FT -19.0 65.32 na The maximum velocity is 14.01 and it occurs in the pipe between nodes 1 and 2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftngs Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 Di 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 K Factor = 4.79 H2 13.20 0.874 0 3.0 1.000 7.261 K Factor = 4.90 to 150.0 0.0 3.000 -0.433 D2 13.2 0.0970 0.0 4.000 0.388 Vel = 7.06 0.0 13.20 7.216 K Factor = 4.91 H3 0.0 0.874 N 7.0 1.000 12.872 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 12.439 K Factor =0 H4 0.0 0.874 N 7.0 1.000 14.700 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 14.267 K Factor = 0 H5 0.0 0.874 0 3.0 1.000 15.655 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 15.222 K Factor = 0 H6 0.0 0.874 0 3.0 1.000 12.068 to 150.0 0.0 3.000 -0.433 D6 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 11.635 K Factor =0 H7 0.0 0.874 N 7.0 1.000 12.145 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 11.712 K Factor =0 Di 13.00 0.874 0 3.0 5.583 7.361 to 150.0 0.0 3.000 0.0 13.0 0.0945 0.0 8.583 0.811 Vel = 6.95 0.0 13.00 8.172 K Factor = 4.55 D2 13.20 0.874 R 1.0 8.833 7.216 to 150.0 0.0 1.000 0.0 13.2 0.0972 0.0 9.833 0.956 Vel = 7.06 1 13.00 0.874 N 7.0 1.917 8.172 to 150.0 0.0 7.000 0.0 2 26.2 0.3452 0.0 8.917 3.078 Vel = 14.01 2 0.0 0.874 0 3.0 10.000 11.250 to 150.0 0.0 3.000 -4.331 3 26.2 0.3453 0.0 13.000 4.489 Vel = 14.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -15.15 0.874 2R 2.0 12.750 11.408 to 150.0 0.0 2.000 0.0 4 11.05 0.0699 0.0 14.750 1.031 Vel= 5.91 0.0 11.05 12.439 K Factor= 3.13 D3 0.0 0.874 0 3.0 1.667 12.439 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vet = 0 4 11.05 0.874 N 7.0 3.333 12.439 to 150.0 0.0 7.000 0.0 5 11.05 0.0698 0.0 10.333 0.721 Vel= 5.91 5 0.0 0.874 2R 2.0 10.833 13.160 to 150.0 0 3.0 5.000 0.0 6 11.05 0.0699 0.0 15.833 1.107 Vet = 5.91 0.0 11.05 14.267 K Factor = 2.93 D4 0.0 0.874 N 7.0 9.083 14.267 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vet = 0 6 11.05 0.874 N 7.0 5.667 14.267 to 150.0 R 1.0 8.000 0.0 D5 11.05 0.0699 0.0 13.667 0.955 Vel= 5.91 D5 0.0 0.874 0 3.0 2.250 15.222 to 150.0 0.0 3.000 0.0 7 11.05 0.0697 0.0 5.250 0.366 Vet = 5.91 7 -6.89 0.874 N 7.0 4.667 15.588 to 150.0 0.0 7.000 0.0 8 4.16 0.0115 0.0 11.667 0.134 Vet= 2.22 8 0.0 0.874 N 7.0 10.000 15.722 to 150.0 0.0 7.000 -4.331 15 4.16 0.0115 0.0 17.000 0.195 Vet = 2.22 15 0.0 0.874 R 1.0 3.333 11.586 to 150.0 0.0 1.000 0.0 D6 4.16 0.0113 0.0 4.333 0.049 Vet = 2.22 D6 0.0 0.874 0 3.0 0.583 11.635 to 150.0 0.0 3.000 0.0 16 4.16 0.0114 0.0 3.583 0.041 Vet= 2.22 16 -2.01 0.874 0 3.0 7.583 11.676 to 150.0 0.0 3.000 0.0 17 2.15 0.0034 0.0 10.583 0.036 Vel= 1.15 0.0 2.15 11.712 K Factor = 0.63 D7 0.0 0.874 R 1.0 9.083 11.712 to 150.0 0.0 1.000 0.0 17 0.0 0.0 0.0 10.083 0.0 Vet = 0 17 2.15 0.874 R 1.0 13.500 11.712 to 150.0 0 3.0 4.000 0.0 18 2.15 0.0034 0.0 17.500 0.060 Vet = 1.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Page 7 Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn 18 -4.15 0.874 N 7.0 7.583 11.772 to 150.0 0.0 7.000 0.0 19 -2.0 -0.0030 0.0 14.583 -0.044 Vel= 1.07 19 0.0 0.874 R 1.0 13.500 11.728 to 150.0 0 3.0 4.000 0.0 16 -2.0 -0.0030 0.0 17.500 -0.052 Vet = 1.07 0.0 -2.00 11.676 K Factor = -0.59 18 4.16 0.874 N 7.0 0.500 11.772 to 150.0 0.0 7.000 0.0 20 4.16 0.0113 0.0 7.500 0.085 Vel= 2.22 20 0.0 0.874 0 3.0 10.000 11.857 to 150.0 0.0 3.000 4.331 10 4.16 0.0115 0.0 13.000 0.149 Vet = 2.22 0.0 4.16 16.337 K Factor = 1.03 7 6.89 0.874 0 3.0 7.583 15.588 to 150.0 0.0 3.000 0.0 9 6.89 0.0292 0.0 10.583 0.309 Vet = 3.68 9 0.0 0.874 2R 2.0 13.083 15.897 to 150.0 0.0 2.000 0.0 10 6.89 0.0292 0.0 15.083 0.440 Vet = 3.68 10 4.16 0.874 R 1.0 2.333 16.337 to 150.0 0.0 1.000 0.0 11 11.05 0.0699 0.0 3.333 0.233 Vet = 5.91 11 15.15 1.101 N 7.0 1.583 16.570 to 150.0 0.0 7.000 0.0 12 26.2 0.1122 0.0 8.583 0.963 VeI= 8.83 12 0.0 1.101 N 7.0 10.000 17.533 to 150.0 0.0 7.000 4.331 21 26.2 0.1121 0.0 17.000 1.906 Vet= 8.83 0.0 26.20 23.770 K Factor = 5.37 11 -15.16 0.874 N 7.0 3.333 16.570 to 150.0 0.0 7.000 0.0 13 -15.16 -0.1254 0.0 10.333 -1.296 Vet = 8.11 13 0.0 0.874 2R 2.0 24.250 15.274 to 150.0 0 3.0 5.000 0.0 14 -15.16 -0.1254 0.0 29.250 -3.667 Vet = 8.11 14 0.0 0.874 R 1.0 0.583 11.607 to 150.0 0.0 1.000 0.0 3 -15.16 -0.1257 0.0 1.583 -0.199 Vet= 8.11 0.0 -15.16 11.408 KFactor= -4.49 21 26.20 1.101 N 7.0 4.750 23.770 to 150.0 0.0 7.000 0.0 22 26.2 0.1122 0.0 11.750 1.318 Vet = 8.83 22 0.0 1.101 R 1.0 8.167 25.088 to 150.0 N 7.0 8.000 0.0 TR 26.2 0.1122 0.0 16.167 1.814 Vel= 8.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn 0.0 26.20 26.902 K Factor = 5.05 TR 26.20 1.101 2R 2.0 8.000 26.902 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 26.2 0.1122 Fsp 0.0 26.562 2.979 Vel= 8.83 N 7.0 BR 5.00 1.101 0 5.0 2.000 36.346 Qa=5 to 150.0 0.0 5.000 0.0 X 31.2 0.1549 0.0 7.000 1.084 Vel = 10.51 X 0.0 1.244 0.0 5.000 37.430 to 150.0 0.0 0.0 2.166 EL 31.2 0.0854 0.0 5.000 0.427 Vel = 8.24 EL 0.0 1.244 0.0 65.000 40.023 to 150.0 0.0 0.0 0.0 Ml 31.2 0.0855 0.0 65.000 5.556 Vel = 8.24 Ml 0.0 1.025 0.0 1.000 45.579 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 31.2 0.2200 0.0 1.000 0.220 Vel = 12.13 M2 0.0 0.995 T 5.841 28.000 49.799 to 150.0 0.0 5.841 0.0 CM 31.2 0.2537 0.0 33.841 8.584 Vel= 12.87 CM -14.09 7.98 3F 40.774 324.000 58.383 to 150.0 T 52.855 93.629 0.0 100 17.11 0.0 0.0 417.629 0.001 Vel= 0.11 100 0.87 7.98 1 52.855 295.000 58.384 to 150.0 0.0 52.855 0.0 101 17.98 0.0 0.0 347.855 0.002 Vel = 0.12 0.0 17.98 58.386 K Factor = 2.35 100 -0.87 7.98 21 105.71 381.000 58.384 to 150.0 0.0 105.710 -1.299 105 -0.87 0.0 0.0 486.710 0.0 Vel = 0.01 0.0 -0.87 57.085 K Factor = -0.12 101 17.98 11.65 F 17.441 175.000 58.386 to 150.0 T 80.498 97.939 0.0 102 17.98 0.0 0.0 272.939 0.0 Vel = 0.05 102 -31.20 11.65 F 17.441 532.000 58.386 to 150.0 T 80.498 97.939 0.0 103 -13.22 0.0 0.0 629.939 -0.001 Vel = 0.04 103 0.0 7.98 T 52.855 542.000 58.385 to 150.0 0.0 52.855 0.0 104 -13.22 0.0 0.0 594.855 -0.001 Vel = 0.08 104 14.09 11.65 T 80.498 207.000 58.384 to 150.0 0.0 80.498 -1.299 105 0.87 0.0 0.0 287.498 0.0 Vel = 0 0.0 0.87 57.085 K Factor = 0.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 104 -14.09 7.98 T 52.855 542.000 58.384 to 150.0 0.0 52.855 0.0 CM -14.09 0.0 0.0 594.855 -0.001 Vel = 0.09 0.0 -14.09 58.383 K Factor = -1.84 102 31.20 11.65 3T 241.494 1439.000 58.386 to 150.0 0.0 241.494 6.930 FT 31.2 0.0 0.0 1680.494 0.002 Vel = 0.09 0.0 31.20 65.318 K Factor = 3.86 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name CYPRESS AT THE PRESERVE Building : PLAN 2X Location : CALC AREA 2 System : 1 Contract Data File : PLAN2X CA2 20X20.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page 1 CYPRESS ATTHE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - CALC AREA 2 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9'-0" OCCUPANCY - LIGHT HAZARD Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: (X)l ( )2 ( )4 )Other )Specific Ruling Made by Date Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction Domestic Flow Added - 5 Gpm Sprinkler or Nozzle Additional Flow Added - Gpm Make RELIABLE Model RFC49 Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 Note: Temperature Rating 165 Calculation Gpm Required 20.024 Psi Required 38.530 At BR Summary C-Factor Used: Overhead 150 Underground 150 S Y S T E M D E S I G N W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 94 R Residual (Psi) - 66 Flow (Gpm) - 3750 S Elevation - 114 P Location: P L Source of Information: Y Pump Data: Tank or Reservoir: Rated Cap. Cap. 8 Psi Elev. Elev. Other Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE Page 2 Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 16.458 C2 - Residual Pressure: 59.4 D2 - System Flow : 20.024 C2 - Residual Flow : 3750 D2 - System Pressure : 62.180 Hose ( Demand) : 5 D3 - System Demand : 25.024 Safety Margin : 22.418 150 140 130 p120 R11° E 100 90 ell c80 u 70 - C2 R 60 D3 E 50 40 30 20 Dl I I I 10 I I I I 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name ½ 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rpn- 9.0 24.57 na 9.0 24.57 na 19.0 4.9 16.7 na 20.02 0.05 400 16.7 19.0 20.84 na 19.0 21.61 na 29.0 17.89 na 29.0 17.95 na 10.0 24.14 na 10.0 24.14 na 10.0 24.14 na 10.0 24.14 na 20.0 19.81 na 20.0 17.95 na 20.0 18.93 na 20.0 19.51 na 20.0 20.41 na 20.0 20.41 na 20.0 21.18 na 20.0 21.48 na 20.0 21.59 na 30.0 17.41 na 30.0 17.45 na 30.0 17.49 na 30.0 17.52 na 30.0 17.52 na 30.0 17.56 na 30.0 17.53 na 30.0 17.63 na 20.0 21.73 na 20.0 22.09 na 20.0 22.27 na 20.0 22.86 na 20.0 21.66 na 20.0 19.9 na 10.0 28.35 na 10.0 29.15 na 10.0 30.25 na 2.0 38.53 na 5.0 2.0 39.25 na -3.0 41.7 na -3.0 45.39 na -3.0 49.54 na -3.0 55.25 na -3.0 55.25 na -3.0 55.25 na -3.0 55.25 na -3.0 55.25 na -3.0 55.25 na -19.0 62.18 na The maximum velocity is 10.71 and it occurs in the pipe between nodes H3 and D3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 24.573 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 24.140 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 24.573 to 150.0 0.0 3.000 -0.433 D2 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 24.140 K Factor =0 H3 20.02 0.874 N 7.0 1.000 16.700 K Factor =4.90 to 150.0 0.0 7.000 -0.433 D3 20.02 0.2099 0.0 8.000 1.679 Vel = 10.71 0.0 20.02 17.946 K Factor = 4.73 H4 0.0 0.874 N 7.0 1.000 20.841 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 20.408 K Factor = 0 H5 0.0 0.874 0 3.0 1.000 21.614 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 21.181 K Factor =0 H6 0.0 0.874 0 3.0 1.000 17.887 to 150.0 0.0 3.000 -0.433 D6 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 17.454 K Factor = 0 H7 0.0 0.874 N 7.0 1.000 17.949 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 17.516 K Factor = 0 Di 0.0 0.874 0 3.0 5.583 24.140 to 150.0 0.0 3.000 0.0 1 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 24.140 K Factor = 0 D2 0.0 0.874 R 1.0 8.833 24.140 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vel = 0 1 0.0 0.874 N 7.0 1.917 24.140 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 24.140 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -10.16 0.874 2R 2.0 12.750 19.809 to 150.0 0.0 2.000 0.0 4 -10.16 -0.0599 0.0 14.750 -0.883 Vel= 5.43 0.0 -10.16 18.926 KFactor= -2.34 D3 20.02 0.874 0 3.0 1.667 17.946 to 150.0 0.0 3.000 0.0 4 20.02 0.2100 0.0 4.667 0.980 Vel = 10.71 4 -10.16 0.874 N 7.0 3.333 18.926 to 150.0 0.0 7.000 0.0 5 9.86 0.0566 0.0 10.333 0.585 Vet = 5.27 5 0.0 0.874 2R 2.0 10.833 19.511 to 150.0 0 3.0 5.000 0.0 6 9.86 0.0567 0.0 15.833 0.897 Vet = 5.27 0.0 9.86 20.408 K Factor = 2.18 D4 0.0 0.874 N 7.0 9.083 20.408 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vel = 0 6 9.86 0.874 N 7.0 5.667 20.408 to 150.0 R 1.0 8.000 0.0 D5 9.86 0.0566 0.0 13.667 0.773 Vet = 5.27 D5 0.0 0.874 0 3.0 2.250 21.181 to 150.0 0.0 3.000 0.0 7 9.86 0.0566 0.0 5.250 0.297 Vet = 5.27 7 -6.15 0.874 N 7.0 4.667 21.478 to 150.0 0.0 7.000 0.0 8 3.71 0.0093 0.0 11.667 0.109 Vel = 1.98 8 0.0 0.874 N 7.0 10.000 21.587 to 150.0 0.0 7.000 -4.331 15 3.71 0.0093 0.0 17.000 0.158 Vel = 1.98 15 0.0 0.874 R 1.0 3.333 17.414 to 150.0 0.0 1.000 0.0 D6 3.71 0.0092 0.0 4.333 0.040 Vet = 1.98 D6 0.0 0.874 0 3.0 0.583 17.454 to 150.0 0.0 3.000 0.0 16 3.71 0.0092 0.0 3.583 0.033 Vel = 1.98 16 -1.79 0.874 0 3.0 7.583 17.487 to 150.0 0.0 3.000 0.0 17 1.92 0.0027 0.0 10.583 0.029 Vel= 1.03 0.0 1.92 17.516 K Factor = 0.46 D7 0.0 0.874 R 1.0 9.083 17.516 to 150.0 0.0 1.000 0.0 17 0.0 0.0 0.0 10.083 0.0 Vel = 0 17 1.92 0.874 R 1.0 13.500 17.516 to 150.0 0 3.0 4.000 0.0 18 1.92 0.0027 0.0 17.500 0.048 Vel = 1.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. 'C' Fitting or Pipe Ftng's Pt Pt Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -3.71 0.874 N 7.0 7.583 17.564 to 150.0 0.0 7.000 0.0 19 -1.79 -0.0024 0.0 14.583 -0.035 Vel = 0.96 19 0.0 0.874 R 1.0 13.500 17.529 to 150.0 0 3.0 4.000 0.0 16 -1.79 -0.0024 0.0 17.500 -0.042 Vel = 0.96 0.0 -1.79 17.487 K Factor = -0.43 18 3.71 0.874 N 7.0 0.500 17.564 to 150.0 0.0 7.000 0.0 20 3.71 0.0093 0.0 7.500 0.070 Vet = 1.98 20 0.0 0.874 0 3.0 10.000 17.634 to 150.0 0.0 3.000 4.331 10 3.71 0.0092 0.0 13.000 0.120 Vet = 1.98 0.0 3.71 22.085 K Factor = 0.79 7 6.15 0.874 0 3.0 7.583 21.478 to 150.0 0.0 3.000 0.0 9 6.15 0.0237 0.0 10.583 0.251 Vet = 3.29 9 0.0 0.874 2R 2.0 13.083 21.729 to 150.0 0.0 2.000 0.0 10 6.15 0.0236 0.0 15.083 0.356 Vel = 3.29 10 3.71 0.874 R 1.0 2.333 22.085 to 150.0 0.0 1.000 0.0 11 9.86 0.0567 0.0 3.333 0.189 Vel = 5.27 11 10.16 1.101 N 7.0 1.583 22.274 to 150.0 0.0 7.000 0.0 12 20.02 0.0682 0.0 8.583 0.585 Vel = 6.75 12 0.0 1.101 N 7.0 10.000 22.859 to 150.0 0.0 7.000 4.331 21 20.02 0.0682 0.0 17.000 1.160 Vel = 6.75 0.0 20.02 28.350 K Factor = 3.76 11 -10.16 0.874 N 7.0 3.333 22.274 to 150.0 0.0 7.000 0.0 13 -10.16 -0.0599 0.0 10.333 -0.619 Vet = 5.43 13 0.0 0.874 2R 2.0 24.250 21.655 to 150.0 0 3.0 5.000 0.0 14 -10.16 -0.0599 0.0 29.250 -1.751 Vel= 5.43 14 0.0 0.874 R 1.0 0.583 19.904 to 150.0 0.0 1.000 0.0 3 -10.16 -0.0600 0.0 1.583 -0.095 Vel= 5.43 0.0 -10.16 19.809 KFactor= -2.28 21 20.02 1.101 N 7.0 4.750 28.350 to 150.0 0.0 7.000 0.0 22 20.02 0.0682 0.0 11.750 0.801 Vet = 6.75 22 0.0 1.101 R 1.0 8.167 29.151 to 150.0 N 7.0 8.000 0.0 TR 20.02 0.0682 0.0 16.167 1.102 Vel= 6.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Of Pf/Ft Eqv. Ln. Total Pf Pn 0.0 20.02 30.253 K Factor = 3.64 TR 20.02 1.101 2R 2.0 8.000 30.253 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 20.02 0.0682 Fsp 0.0 26.562 1.812 Vel = 6.75 N 7.0 BR 5.00 1.101 0 5.0 2.000 38.530 Qa=5 to 150.0 0.0 5.000 0.0 X 25.02 0.1030 0.0 7.000 0.721 Vel = 8.43 X 0.0 1.244 0.0 5.000 39.251 to 150.0 0.0 0.0 2.166 EL 25.02 0.0566 0.0 5.000 0.283 Vel = 6.60 EL 0.0 1.244 0.0 65.000 41.700 to 150.0 0.0 0.0 0.0 Ml 25.02 0.0568 0.0 65.000 3.694 Vel = 6.60 Ml 0.0 1.025 0.0 1.000 45.394 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 25.02 0.1460 0.0 1.000 0.146 Vel = 9.73 M2 0.0 0.995 T 5.841 28.000 49.540 to 150.0 0.0 5.841 0.0 CM 25.02 0.1686 0.0 33.841 5.706 Vel = 10.32 CM -11.30 7.98 3F 40.774 324.000 55.246 to 150.0 1 52.855 93.629 0.0 100 13.72 0.0 0.0 417.629 0.001 Vel = 0.09 100 0.70 7.98 T 52.855 295.000 55.247 to 150.0 0.0 52.855 0.0 101 14.42 0.0 0.0 347.855 0.001 Vel = 0.09 0.0 14.42 55.248 K Factor = 1.94 100 -0.70 7.98 2T 105.71 381.000 55.247 to 150.0 0.0 105.710 -1.299 105 -0.7 0.0 0.0 486.710 0.0 Vel = 0 0.0 -0.70 53.948 K Factor = -0.10 101 14.42 11.65 F 17.441 175.000 55.248 to 150.0 T 80.498 97.939 0.0 102 14.42 0.0 0.0 272.939 0.0 Vel = 0.04 102 -25.02 11.65 F 17.441 532.000 55.248 to 150.0 1 80.498 97.939 0.0 103 -10.6 0.0 0.0 629.939 0.0 Vel = 0.03 103 0.0 7.98 T 52.855 542.000 55.248 to 150.0 0.0 52.855 0.0 104 -10.6 0.0 0.0 594.855 -0.001 Vel = 0.07 104 11.30 11.65 1 80.498 207.000 55.247 to 150.0 0.0 80.498 -1.299 105 0.7 0.0 0.0 287.498 0.0 Vel = 0 0.0 0.70 53.948 KFactor= 0.10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Ref. Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv Notes Point Ot Pf/Ft Eqv. Ln. Total Pf Pn 104 -11.30 7.98 T 52.855 542.000 55.247 to 150.0 0.0 52.855 0.0 CM -11.3 0.0 0.0 594.855 -0.001 Vel = 0.07 0.0 -11.30 55.246 K Factor = -1.52 102 25.02 11.65 31 241.494 1439.000 55.248 to 150.0 0.0 241.494 6.930 FT 25.02 0.0 0.0 1680.494 0.002 Vel = 0.08 0.0 25.02 62.180 K Factor = 3.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS ATTHE PRESERVE Building : PLAN 2X Location : CALC AREA 3 System 1 Contract Data File : PLAN2X CA3 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page CYPRESS ATTHE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Location - CALC AREA 3 Building - PLAN 2X Contractor - NP MECHANICAL Calculated By - MG Construction: (X) Combustible OCCUPANCY - LIGHT HAZARD Date - 5/25/17 System No. - 1 Contract No. - Drawing No. - 1 Non-Combustible Ceiling Height 9'-0" S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 27.77 Psi Required 33.572 At BR Summary C-Factor Used: Overhead 150 Underground 150 Pump Data: Tank or Reservoir: Rated Cap. Cap. 6 Psi Elev. Elev. Other Well Proof Flow Gpm W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 94 R Residual (Psi) - 66 Flow (Gpm) - 3750 S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE Page 2 Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 16.458 C2 - Residual Pressure: 594 D2 - System Flow : 27.77 02 - Residual Flow : 3750 D2 - System Pressure : 64.049 Hose ( Demand) : 5 D3 - System Demand : 32.77 Safety Margin : 20.549 150 140 130 p120 R° E10° 90 CI U 70 80 UZ C2 R E5° 40 30 20 Dl 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 9.0 15.63 na 9.0 15.63 na 19.0 10.62 na 19.0 4.9 7.04 na 19.0 4.9 9.09 na 29.0 7.25 na 29.0 7.45 na 10.0 15.2 na 10.0 15.2 na 10.0 15.2 na 10.0 15.2 na 20.0 10.87 na 20.0 10.19 na 20.0 10.19 na 20.0 9.71 na 20.0 7.36 na 20.0 8.97 na 20.0 9.13 na 20.0 10.12 na 20.0 10.48 na 30.0 6.68 na 30.0 6.81 na 30.0 6.92 na 30.0 7.02 na 30.0 7.02 na 30.0 7.18 na 30.0 7.07 na 30.0 7.41 na 20.0 10.96 na 20.0 12.15 na 20.0 12.78 na 20.0 13.85 na 20.0 12.3 na 20.0 10.94 na 10.0 20.3 na 10.0 21.77 na 10.0 23.79 na 2.0 33.57 na 2.0 34.76 na -3.0 37.39 na -3.0 43.48 na -3.0 47.72 na -3.0 57.11 na -3.0 57.12 na -3.0 57.12 na -3.0 57.12 na -3.0 57.12 na -3.0 57.12 na -19.0 64.05 na 13.0 0.05 256 7.039 14.77 0.05 256 7.0 5.0 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rn The maximum velocity is 13.52 and it occurs in the pipe between nodes M2 and CM Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 15.634 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 15.201 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 15.634 to 150.0 0.0 3.000 -0.433 D2 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 15.201 K Factor =0 H3 0.0 0.874 N 7.0 1.000 10.620 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 10.187 K Factor =0 H4 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D4 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 K Factor = 4.79 H5 14.77 0.874 0 3.0 1.000 9.085 K Factor =4.90 to 150.0 0.0 3.000 -0.433 D5 14.77 0.1195 0.0 4.000 0.478 Vel= 7.90 0.0 14.77 9.130 K Factor = 4.89 H6 0.0 0.874 0 3.0 1.000 7.247 to 150.0 0.0 3.000 -0.433 D6 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 6.814 K Factor =0 H7 0.0 0.874 N 7.0 1.000 7.455 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 7.022 K Factor = 0 Dl 0.0 0.874 0 3.0 5.583 15.201 to 150.0 0.0 3.000 0.0 1 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 15.201 K Factor =0 D2 0.0 0.874 R 1.0 8.833 15.201 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vel = 0 1 0.0 0.874 N 7.0 1.917 15.201 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 15.201 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C'.or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn 3 -8.85 0.874 2R 2.0 12.750 10.870 to 150.0 0.0 2.000 0.0 4 -8.85 -0.0463 0.0 14.750 -0.683 Vel = 4.73 0.0 -8.85 10.187 K Factor = -2.77 D3 0.0 0.874 0 3.0 1.667 10.187 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vel = 0 4 -8.85 0.874 N 7.0 3.333 10.187 to 150.0 0.0 7.000 0.0 5 -8.85 -0.0464 0.0 10.333 -0.479 Vel = 4.73 5 0.0 0.874 2R 2.0 10.833 9.708 to 150.0 0 3.0 5.000 0.0 6 -8.85 -0.0464 0.0 15.833 -0.734 Vel = 4.73 0.0 -8.85 8.974 K Factor = -2.95 D4 13.00 0.874 N 7.0 9.083 7.361 to 150.0 R 1.0 8.000 0.0 6 13.0 0.0944 0.0 17.083 1.613 Vel = 6.95 6 -8.85 0.874 N 7.0 5.667 8.974 to 150.0 R 1.0 8.000 0.0 D5 4.15 0.0114 0.0 13.667 0.156 Vel = 2.22 D5 14.77 0.874 0 3.0 2.250 9.130 to 150.0 0.0 3.000 0.0 7 18.92 0.1890 0.0 5.250 0.992 Vel= 10.12 7 -11.80 0.874 N 7.0 4.667 10.122 to 150.0 0.0 7.000 0.0 8 7.12 0.0310 0.0 11.667 0.362 Vel = 3.81 8 0.0 0.874 N 7.0 10.000 10.484 to 150.0 0.0 7.000 -4.331 15 7.12 0.0310 0.0 17.000 0.527 Vel = 3.81 15 0.0 0.874 R 1.0 3.333 6.680 to 150.0 0.0 1.000 0.0 D6 7.12 0.0309 0.0 4.333 0.134 Vel = 3.81 D6 0.0 0.874 0 3.0 0.583 6.814 to 150.0 0.0 3.000 0.0 16 7.12 0.0310 0.0 3.583 0.111 Vel= 3.81 16 -3.43 0.874 0 3.0 7.583 6.925 to 150.0 0.0 3.000 0.0 17 3.69 0.0092 0.0 10.583 0.097 Vel= 1.97 0.0 3.69 7.022 K Factor = 1.39 D7 0.0 0.874 R 1.0 9.083 7.022 to 150.0 0.0 1.000 0.0 17 0.0 0.0 0.0 10.083 0.0 Vel = 0 17 3.69 0.874 R 1.0 13.500 7.022 to 150.0 0 3.0 4.000 0.0 18 3.69 0.0091 0.0 17.500 0.160 Vel = 1.97 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pt Pn 18 -7.12 0.874 N 7.0 7.583 7.182 to 150.0 0.0 7.000 0.0 19 -3.43 -0.0080 0.0 14.583 -0.117 Vet= 1.83 19 0.0 0.874 R 1.0 13.500 7.065 to 150.0 0 3.0 4.000 0.0 16 -3.43 -0.0080 0.0 17.500 -0.140 Vel = 1.83 0.0 -3.43 6.925 K Factor = -1.30 18 7.12 0.874 N 7.0 0.500 7.182 to 150.0 0.0 7.000 0.0 20 7.12 0.0311 0.0 7.500 0.233 Vel= 3.81 20 0.0 0.874 0 3.0 10.000 7.415 to 150.0 0.0 3.000 4.331 10 7.12 0.0309 0.0 13.000 0.402 Vel = 3.81 0.0 7.12 12.148 K Factor = 2.04 7 11.80 0.874 0 3.0 7.583 10.122 to 150.0 0.0 3.000 0.0 9 11.8 0.0790 0.0 10.583 0.836 Vel = 6.31 9 0.0 0.874 2R 2.0 13.083 10.958 to 150.0 0.0 2.000 0.0 10 11.8 0.0789 0.0 15.083 1.190 Vet = 6.31 10 7.12 0.874 R 1.0 2.333 12.148 to 150.0 0.0 1.000 0.0 11 18.92 0.1890 0.0 3.333 0.630 Vel= 10.12 11 8.85 1.101 N 7.0 1.583 12.778 to 150.0 0.0 7.000 0.0 12 27.77 0.1249 0.0 8.583 1.072 Vel= 9.36 12 0.0 1.101 N 7.0 10.000 13.850 to 150.0 0.0 7.000 4.331 21 27.77 0.1249 0.0 17.000 2.123 Vel = 9.36 0.0 27.77 20.304 K Factor = 6.16 11 -8.85 0.874 N 7.0 3.333 12.778 to 150.0 0.0 7.000 0.0 13 -8.85 -0.0463 0.0 10.333 -0.478 Vel = 4.73 13 0.0 0.874 2R 2.0 24.250 12.300 to 150.0 0 3.0 5.000 0.0 14 -8.85 -0.0464 0.0 29.250 -1.356 Vel = 4.73 14 0.0 0.874 R 1.0 0.583 10.944 to 150.0 0.0 1.000 0.0 3 -8.85 -0.0467 0.0 1.583 -0.074 Vet = 4.73 0.0 -8.85 10.870 K Factor = -2.68 21 27.77 1.101 N 7.0 4.750 20.304 to 150.0 0.0 7.000 0.0 22 27.77 0.1249 0.0 11.750 1.467 Vet= 9.36 22 0.0 1.101 R 1.0 8.167 21.771 to 150.0 N 7.0 8.000 0.0 TR 27.77 0.1249 0.0 16.167 2.019 Vel = 9.36 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 27.77 23.790 K Factor = 5.69 TR 27.77 1.101 2R 2.0 8.000 23.790 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 27.77 0.1249 Fsp 0.0 26.562 3.317 Vel = 9.36 N 7.0 BR 5.00 1.101 0 5.0 2.000 33.572 Qa=5 to 150.0 0.0 5.000 0.0 X 32.77 0.1696 0.0 7.000 1.187 Vel = 11.04 X 0.0 1.244 0.0 5.000 34.759 to 150.0 0.0 0.0 2.166 EL 32.77 0.0936 0.0 5.000 0.468 Vel = 8.65 EL 0.0 1.244 0.0 65.000 37.393 to 150.0 0.0 0.0 0.0 Ml 32.77 0.0936 0.0 65.000 6.083 Vel = 8.65 Ml 0.0 1.025 0.0 1.000 43.476 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 32.77 0.2400 0.0 1.000 0.240 Vel = 12.74 M2 0.0 0.995 1 5.841 28.000 47.716 to 150.0 0.0 5.841 0.0 CM 32.77 0.2777 0.0 33.841 9.398 Vel = 13.52 CM -14.80 7.98 3F 40.774 324.000 57.114 to 150.0 1 52.855 93.629 0.0 100 17.97 0.0 0.0 417.629 0.002 Vel = 0.12 100 0.92 7.98 T 52.855 295.000 57.116 to 150.0 0.0 52.855 0.0 101 18.89 0.0 0.0 347.855 0.001 Vel = 0.12 0.0 18.89 57.117 K Factor = 2.50 100 -0.92 7.98 21 105.71 381.000 57.116 to 150.0 0.0 105.710 -1.299 105 -0.92 0.0 0.0 486.710 -0.001 Vel = 0.01 0.0 -0.92 55.816 K Factor = -0.12 101 18.89 11.65 F 17.441 175.000 57.117 to 150.0 T 80.498 97.939 0.0 102 18.89 0.0 0.0 272.939 0.0 Vel = 0.06 102 -32.77 11.65 F 17.441 532.000 57.117 to 150.0 1 80.498 97.939 0.0 103 -13.88 0.0 0.0 629.939 0.0 Vel = 0.04 103 0.0 7.98 T 52.855 542.000 57.117 to 150.0 0.0 52.855 0.0 104 -13.88 0.0 0.0 594.855 -0.001 Vel = 0.09 104 14.80 11.65 1 80.498 207.000 57.116 to 150.0 0.0 80.498 -1.299 105 0.92 0.0 0.0 287.498 -0.001 Vel = 0 0.0 0.92 55.816 K Factor = 0.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. C" Fitting or Pipe Ftngs Pt Pt Pe Pv ******* Notes Point Ot Pf/Ft Eqv. Ln. Total Pf Pn 104 -14.80 7.98 T 52.855 542.000 57.116 to 150.0 0.0 52.855 0.0 CM -14.8 0.0 0.0 594.855 -0.002 Vel = 0.09 0.0 -14.80 57.114 K Factor= -1.96 102 32.77 11.65 31 241.494 1439.000 57.117 to 150.0 0.0 241.494 6.930 FT 32.77 0.0 0.0 1680.494 0.002 Vel = 0.10 0.0 32.77 64.049 K Factor = 4.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS ATTHE PRESERVE Building : PLAN 2X Location : CALC AREA 4 System : 1 Contract Data File : PLAN2X CA4 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page 1 CYPRESS AT THE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - CALC AREA 4 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9T_0TI OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 27.196 Psi Required 37.392 At BR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - B Static (Psi) - 94 R Residual (Psi) - 66 Flow (Gpm) - 3750 S Elevation - 114 P Location: P L Source of Information: Y Pump Data: Tank or Reservoir: Rated Cap. Cap. @ Psi Elev. Elev. Other Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical Page 2 CYPRESS AT THE PRESERVE Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 20.789 C2 - Residual Pressure: 59.4 D2 - System Flow :27.196 C2 - Residual Flow : 3750 D2 - System Pressure : 67.311 Hose ( Demand) : 5 D3 - System Demand : 32.196 Safety Margin : 17.288 150 140 130 p120 R° E10° 90 --C-i— S 80 D2 U 70 - G C2 R 60D3 E5° 40 30 20 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N 1 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS ATTHE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name ½ 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90ElI Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node No. Elevation K-Fact Pt Actual Pn Flow Density Actual Area Press Req. Hi 9.0 21.09 na H2 9.0 21.09 na H3 19.0 16.52 na H4 19.0 16.11 na H5 19.0 15.89 na H6 29.0 4.9 8.39 na 14.2 0.05 256 7.0 H7 29.0 4.9 7.04 na 13.0 0.05 256 7.039 Dl 10.0 20.65 na D2 10.0 20.65 na 1 10.0 20.65 na 2 10.0 20.65 na 3 20.0 16.32 na D3 20.0 16.09 na 4 20.0 16.09 na 5 20.0 15.93 na D4 20.0 15.67 na 6 20.0 15.67 na D5 20.0 15.46 na 7 20.0 15.37 na 8 20.0 14.44 na 15 30.0 8.75 na D6 30.0 8.4 na 16 30.0 8.42 na D7 30.0 7.36 na 17 30.0 8.31 na 18 30.0 9.18 na 19 30.0 8.83 na 20 30.0 10.14 na 9 20.0 15.68 na 10 20.0 16.13 na 11 20.0 16.98 na 12 20.0 18.01 na 13 20.0 16.81 na 14 20.0 16.35 na 21 10.0 24.38 na 22 10.0 25.79 na TR 10.0 27.74 na BR 2.0 37.39 na 5.0 X 2.0 38.54 na EL -3.0 41.16 na Ml -3.0 47.05 na M2 -3.0 51.28 na CM -3.0 60.38 na 100 -3.0 60.38 na 101 -3.0 60.38 na 102 -3.0 60.38 na 103 -3.0 60.38 na 104 -3.0 60.38 na FT -19.0 67.31 na The maximum velocity is 13.29 and it occurs in the pipe between nodes M2 and CM Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 21.088 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 20.655 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 21.088 to 150.0 0.0 3.000 -0.433 D2 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 20.655 K Factor = 0 H3 0.0 0.874 N 7.0 1.000 16.523 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 16.090 K Factor = 0 H4 0.0 0.874 N 7.0 1.000 16.107 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vet = 0 0.0 0.0 15.674 K Factor =0 H5 0.0 0.874 0 3.0 1.000 15.890 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 15.457 K Factor =0 H6 14.20 0.874 0 3.0 1.000 8.393 K Factor = 4.90 to 150.0 0.0 3.000 -0.433 D6 14.2 0.1110 0.0 4.000 0.444 Vel= 7.59 0.0 14.20 8.404 K Factor = 4.90 H7 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D7 13.0 0.0944 0.0 8.000 0.755 Vet = 6.95 0.0 13.00 7.361 K Factor = 4.79 Dl 0.0 0.874 0 3.0 5.583 20.655 to 150.0 0.0 3.000 0.0 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 20.655 K Factor = 0 D2 0.0 0.874 R 1.0 8.833 20.655 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vet = 0 1 0.0 0.874 N 7.0 1.917 20.655 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 20.655 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vet = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Page 6 Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -4.96 0.874 2R 2.0 12.750 16.324 to 150.0 0.0 2.000 0.0 4 -4.96 -0.0159 0.0 14.750 -0.234 Vel = 2.65 0.0 -4.96 16.090 K Factor = -1.24 D3 0.0 0.874 0 3.0 1.667 16.090 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vel = 0 4 -4.96 0.874 N 7.0 3.333 16.090 to 150.0 0.0 7.000 0.0 5 -4.96 -0.0160 0.0 10.333 -0.165 Vel = 2.65 5 0.0 0.874 2R 2.0 10.833 15.925 to 150.0 0 3.0 5.000 0.0 6 -4.96 -0.0159 0.0 15.833 -0.251 Vel = 2.65 0.0 -4.96 15.674 K Factor = -1.25 D4 0.0 0.874 N 7.0 9.083 15.674 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vel = 0 6 -4.96 0.874 N 7.0 5.667 15.674 to 150.0 R 1.0 8.000 0.0 D5 -4.96 -0.0159 0.0 13.667 -0.217 Vel = 2.65 D5 0.0 0.874 0 3.0 2.250 15.457 to 150.0 0.0 3.000 0.0 7 -4.96 -0.0160 0.0 5.250 -0.084 Vel = 2.65 7 -6.92 0.874 N 7.0 4.667 15.373 to 150.0 0.0 7.000 0.0 8 -11.88 -0.0799 0.0 11.667 -0.932 Vel = 6.35 8 0.0 0.874 N 7.0 10.000 14.441 to 150.0 0.0 7.000 -4.331 15 -11.88 -0.0800 0.0 17.000 -1.360 Vel= 6.35 15 0.0 0.874 R 1.0 3.333 8.750 to 150.0 0.0 1.000 0.0 D6 -11.88 -0.0799 0.0 4.333 -0.346 Vel = 6.35 D6 14.19 0.874 0 3.0 0.583 8.404 to 150.0 0.0 3.000 0.0 16 2.31 0.0039 0.0 3.583 0.014 Vel = 1.24 16 -6.15 0.874 0 3.0 7.583 8.418 to 150.0 0.0 3.000 0.0 17 -3.84 -0.0099 0.0 10.583 -0.105 Vel = 2.05 0.0 -3.84 8.313 K Factor = -1.33 D7 13.00 0.874 R 1.0 9.083 7.361 to 150.0 0.0 1.000 0.0 17 13.0 0.0944 0.0 10.083 0.952 Vel = 6.95 17 -3.84 0.874 R 1.0 13.500 8.313 to 150.0 0 3.0 4.000 0.0 18 9.16 0.0494 0.0 17.500 0.864 Vel = 4.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 18 -15.31 0.874 N 7.0 7.583 9.177 to 150.0 0.0 7.000 0.0 19 -6.15 -0.0237 0.0 14.583 -0.345 Vel = 3.29 19 0.0 0.874 R 1.0 13.500 8.832 to 150.0 0 3.0 4.000 0.0 16 -6.15 -0.0237 0.0 17.500 -0.414 Vel = 3.29 0.0 -6.15 8.418 KFactor= -2.12 18 15.31 0.874 N 7.0 0.500 9.177 to 150.0 0.0 7.000 0.0 20 15.31 0.1279 0.0 7.500 0.959 Vel = 8.19 20 0.0 0.874 0 3.0 10.000 10.136 to 150.0 0.0 3.000 4.331 10 15.31 0.1278 0.0 13.000 1.661 Vel = 8.19 0.0 15.31 16.128 K Factor = 3.81 7 6.92 0.874 0 3.0 7.583 15.373 to 150.0 0.0 3.000 0.0 9 6.92 0.0295 0.0 10.583 0.312 Vel = 3.70 9 0.0 0.874 2R 2.0 13.083 15.685 to 150.0 0.0 2.000 0.0 10 6.92 0.0294 0.0 15.083 0.443 Vel = 3.70 10 15.31 0.874 R 1.0 2.333 16.128 to 150.0 0.0 1.000 0.0 11 22.23 0.2550 0.0 3.333 0.850 Vel = 11.89 11 4.97 1.101 N 7.0 1.583 16.978 to 150.0 0.0 7.000 0.0 12 27.2 0.1201 0.0 8.583 1.031 Vel = 9.17 12 0.0 1.101 N 7.0 10.000 18.009 to 150.0 0.0 7.000 4.331 21 27.2 0.1201 0.0 17.000 2.042 Vel = 9.17 0.0 27.20 24.382 K Factor = 5.51 11 -4.96 0.874 N 7.0 3.333 16.978 to 150.0 0.0 7.000 0.0 13 -4.96 -0.0159 0.0 10.333 -0.164 Vel = 2.65 13 0.0 0.874 2R 2.0 24.250 16.814 to 150.0 0 3.0 5.000 0.0 14 -4.96 -0.0159 0.0 29.250 -0.465 Vel = 2.65 14 0.0 0.874 R 1.0 0.583 16.349 to 150.0 0.0 1.000 0.0 3 -4.96 -0.0158 0.0 1.583 -0.025 Vel= 2.65 0.0 -4.96 16.324 K Factor = -1.23 21 27.20 1.101 N 7.0 4.750 24.382 to 150.0 0.0 7.000 0.0 22 27.2 0.1202 0.0 11.750 1.412 Vel = 9.17 22 0.0 1.101 R 1.0 8.167 25.794 to 150.0 N 7.0 8.000 0.0 TR 27.2 0.1201 0.0 16.167 1.942 Vel = 9.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 27.20 27.736 K Factor = 5.16 TR 27.20 1.101 2R 2.0 8.000 27.736 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 27.2 0.1201 Fsp 0.0 26.562 3.191 Vel= 9.17 N 7.0 BR 5.00 1.101 0 5.0 2.000 37.392 Qa=5 to 150.0 0.0 5.000 0.0 X 32.2 0.1641 0.0 7.000 1.149 Vel = 10.85 X 0.0 1.244 0.0 5.000 38.541 to 150.0 0.0 0.0 2.166 EL 32.2 0.0906 0.0 5.000 0.453 Vel = 8.50 EL 0.0 1.244 0.0 65.000 41.160 to 150.0 0.0 0.0 0.0 Ml 32.2 0.0906 0.0 65.000 5.887 Vel = 8.50 Ml 0.0 1.025 0.0 1.000 47.047 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 32.2 0.2330 0.0 1.000 0.233 Vel= 12.52 M2 0.0 0.995 1 5.841 28.000 51.280 to 150.0 0.0 5.841 0.0 CM 32.2 0.2688 0.0 33.841 9.096 Vel = 13.29 CM -14.55 7.98 3F 40.774 324.000 60.376 to 150.0 T 52.855 93.629 0.0 100 17.65 0.0 0.0 417.629 0.001 Vel= 0.11 100 0.91 7.98 T 52.855 295.000 60.377 to 150.0 0.0 52.855 0.0 101 18.56 0.0 0.0 347.855 0.001 Vel = 0.12 0.0 18.56 60.378 K Factor = 2.39 100 -0.90 7.98 2T 105.71 381.000 60.377 to 150.0 0.0 105.710 -1.299 105 -0.9 0.0 0.0 486.710 0.0 Vel = 0.01 0.0 -0.90 59.078 K Factor = -0.12 101 18.56 11.65 F 17.441 175.000 60.378 to 150.0 T 80.498 97.939 0.0 102 18.56 0.0 0.0 272.939 0.001 Vel = 0.06 102 -32.20 11.65 F 17.441 532.000 60.379 to 150.0 T 80.498 97.939 0.0 103 -13.64 0.0 0.0 629.939 -0.001 Vel = 0.04 103 0.0 7.98 T 52.855 542.000 60.378 to 150.0 0.0 52.855 0.0 104 -13.64 0.0 0.0 594.855 -0.001 Vel = 0.09 104 14.54 11.65 T 80.498 207.000 60.377 to 150.0 0.0 80.498 -1.299 105 0.9 0.0 0.0 287.498 0.0 Vel = 0 0.0 0.90 59.078 K Factor= 0.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 104 -14.54 7.98 T 52.855 542.000 60.377 to 150.0 0.0 52.855 0.0 CM -14.54 0.0 0.0 594.855 -0.001 Vel = 0.09 0.0 -14.54 60.376 K Factor = -1.87 102 32.20 11.65 3T 241.494 1439.000 60.379 to 150.0 0.0 241.494 6.930 FT 32.2 0.0 0.0 1680.494 0.002 Vel = 0.10 0.0 32.20 67.311 K Factor = 3.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS ATTHE PRESERVE Building PLAN 2X Location ALT. CALC AREA 1 System : 1 Contract Data File : ALT. PLAN2X CAl 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page CYPRESS AT THE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Location - ALT. CALC AREA 1 Building - PLAN 2X Contractor - NP MECHANICAL Calculated By - MG Construction: (X) Combustible OCCUPANCY - LIGHT HAZARD Date - 5/25/17 System No. - 1 Contract No. - Drawing No. - 1 Non-Combustible Ceiling Height 9!_0!T S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 Deluge ( ) PreAction B Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 26.204 Psi Required 42.471 At BR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 94 Elev. R Residual (Psi) - 66 Other Well Flow (Gpm) - 3750 Proof Flow Gpm S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical Page 2 CYPRESS AT THE PRESERVE Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 12.127 C2 - Residual Pressure: 59.4 D2 - System Flow : 26.204 C2 - Residual Flow : 3750 D2 - System Pressure : 71.443 Hose (Demand) : 5 D3 - System Demand : 31.204 Safety Margin : 13.153 150 140 130 p120 R 11 E 100 S 90 "Ct s 80 - - __________ u 70 IDA - C2 R 60 E5° 40 30 20 10 - D1 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N"1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name 1/2 3/4 1 1¼ 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for C Factors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 11 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 0.05 256 7.039 0.05 256 7.0 Hi 9.0 4.9 7.04 na 13.0 H2 9.0 4.9 7.26 na 13.2 H3 19.0 12.99 na H4 19.0 15.04 na H5 19.0 16.11 na H6 29.0 12.41 na H7 29.0 12.46 na Dl 10.0 7.36 na D2 10.0 7.22 na 10.0 8.17 na 2 10.0 11.25 na 3 20.0 11.41 na D3 20.0 12.56 na 4 20.0 12.56 na 5 20.0 13.37 na D4 20.0 14.61 na 6 20.0 14.61 na D5 20.0 15.68 na 7 20.0 16.09 na 8 20.0 16.17 na 15 30.0 11.95 na D6 30.0 11.98 na 16 30.0 12.0 na D7 30.0 12.02 na 17 30.0 12.02 na 18 30.0 12.06 na 19 30.0 12.03 na 20 30.0 12.11 na 9 20.0 16.55 na 11 20.0 17.14 na 12 20.0 19.43 na 10 20.0 16.52 na 13 20.0 14.95 na 14 20.0 11.59 na 21 10.0 25.67 na 22 10.0 29.16 na 23 10.0 31.82 na TRA 10.0 33.03 na BR 2.0 42.47 na 5.0 X 2.0 43.56 na EL -3.0 46.15 na Mi -3.0 51.7 na M2 -3.0 55.92 na CM -3.0 64.51 na 100 -3.0 64.51 na 101 -3.0 64.51 na 102 -3.0 64.51 na 103 -3.0 64.51 na 104 -3.0 64.51 na FT -19.0 71.44 na The maximum velocity is 14.01 and it occurs in the pipe between nodes 1 and 2 Computer Programs by Hydratec Inc. Route iii Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C'.or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 13.00 0.874 N 7.0 1.000 7.039 K Factor =4.90 to 150.0 0.0 7.000 -0.433 Di 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 K Factor = 4.79 H2 13.20 0.874 0 3.0 1.000 7.261 K Factor = 4.90 to 150.0 0.0 3.000 -0.433 D2 13.2 0.0970 0.0 4.000 0.388 Vel = 7.06 0.0 13.20 7.216 K Factor = 4.91 H3 0.0 0.874 N 7.0 1.000 12.995 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 12.562 K Factor =0 H4 0.0 0.874 N 7.0 1.000 15.041 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 14.608 K Factor = 0 H5 0.0 0.874 0 3.0 1.000 16.109 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 15.676 K Factor = 0 H6 0.0 0.874 N 7.0 1.000 12.411 to 150.0 0.0 7.000 -0.433 D6 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 11.978 K Factor =0 H7 0.0 0.874 N 7.0 1.000 12.455 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 12.022 K Factor = 0 Di 13.00 0.874 0 3.0 5.583 7.361 to 150.0 0.0 3.000 0.0 1 13.0 0.0945 0.0 8.583 0.811 Vel = 6.95 0.0 13.00 8.172 K Factor = 4.55 D2 13.20 0.874 R 1.0 8.833 7.216 to 150.0 0.0 1.000 0.0 13.2 0.0972 0.0 9.833 0.956 Vel = 7.06 1 13.00 0.874 N 7.0 1.917 8.172 to 150.0 0.0 7.000 0.0 2 26.2 0.3452 0.0 8.917 3.078 Vel = 14.01 2 0.0 0.874 0 3.0 10.000 11.250 to 150.0 0.0 3.000 -4.331 3 26.2 0.3453 0.0 13.000 4.489 Vel = 14.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. '0" or Ftng's Fe Pv Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn 3 -14.46 0.874 2R 2.0 12.750 11.408 to 150.0 0.0 2.000 0.0 4 11.74 0.0782 0.0 14.750 1.154 Vel = 6.28 0.0 11.74 12.562 K Factor = 3.31 D3 0.0 0.874 0 3.0 1.667 12.562 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vel = 0 4 11.74 0.874 N 7.0 3.333 12.562 to 150.0 0.0 7.000 0.0 5 11.74 0.0782 0.0 10.333 0.808 Vel = 6.28 5 0.0 0.874 2R 2.0 10.833 13.370 to 150.0 0 3.0 5.000 0.0 6 11.74 0.0782 0.0 15.833 1.238 Vel= 6.28 0.0 11.74 14.608 K Factor = 3.07 D4 0.0 0.874 N 7.0 9.083 14.608 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vel = 0 6 11.74 0.874 N 7.0 5.667 14.608 to 150.0 R 1.0 8.000 0.0 D5 11.74 0.0781 0.0 13.667 1.068 Vel = 6.28 D5 0.0 0.874 0 3.0 2.250 15.676 to 150.0 0.0 3.000 0.0 7 11.74 0.0783 0.0 5.250 0.411 Vel = 6.28 7 -8.62 0.874 N 7.0 4.667 16.087 to 150.0 0.0 7.000 0.0 8 3.12 0.0067 0.0 11.667 0.078 Vel = 1.67 8 0.0 0.874 N 7.0 10.000 16.165 to 150.0 0.0 7.000 -4.331 15 3.12 0.0068 0.0 17.000 0.115 Vel = 1.67 15 0.0 0.874 R 1.0 3.333 11.949 to 150.0 0.0 1.000 0.0 D6 3.12 0.0067 0.0 4.333 0.029 Vel= 1.67 D6 0.0 0.874 0 3.0 0.583 11.978 to 150.0 0.0 3.000 0.0 16 3.12 0.0067 0.0 3.583 0.024 Vel = 1.67 16 -1.53 0.874 0 3.0 7.583 12.002 to 150.0 0.0 3.000 0.0 17 1.59 0.0019 0.0 10.583 0.020 Vel = 0.85 0.0 1.59 12.022 K Factor = 0.46 D7 0.0 0.874 0 3.0 9.083 12.022 to 150.0 0.0 3.000 0.0 17 0.0 0.0 0.0 12.083 0.0 Vel = 0 17 1.59 0.874 R 1.0 13.500 12.022 to 150.0 0 3.0 4.000 0.0 18 1.59 0.0019 0.0 17.500 0.034 Vel = 0.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref..1c"or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -3.12 0.874 N 7.0 7.583 12.056 to 150.0 0.0 7.000 0.0 19 -1.53 -0.0018 0.0 14.583 -0.026 Vel = 0.82 19 0.0 0.874 2R 2.0 13.500 12.030 to 150.0 0.0 2.000 0.0 16 -1.53 -0.0018 0.0 15.500 -0.028 Vel = 0.82 0.0 -1.53 12.002 K Factor = -0.44 18 3.12 0.874 N 7.0 0.500 12.056 to 150.0 0.0 7.000 0.0 20 3.12 0.0067 0.0 7.500 0.050 Vel = 1.67 20 0.0 0.874 0 3.0 10.000 12.106 to 150.0 0.0 3.000 4.331 10 3.12 0.0068 0.0 13.000 0.088 Vel= 1.67 0.0 3.12 16.525 K Factor = 0.77 7 8.62 0.874 0 3.0 7.583 16.087 to 150.0 0.0 3.000 0.0 9 8.62 0.0441 0.0 10.583 0.467 Vel = 4.61 9 0.0 0.874 0 3.0 10.333 16.554 to 150.0 0.0 3.000 0.0 11 8.62 0.0443 0.0 13.333 0.590 Vel = 4.61 11 17.58 1.101 2N 14.0 6.417 17.144 to 150.0 0.0 14.000 0.0 12 26.2 0.1122 0.0 20.417 2.290 VeI= 8.83 12 0.0 1.101 N 7.0 10.000 19.434 to 150.0 0.0 7.000 4.331 21 26.2 0.1121 0.0 17.000 1.906 Vel= 8.83 0.0 26.20 25.671 K Factor = 5.17 11 -17.58 0.874 R 1.0 2.750 17.144 to 150.0 0.0 1.000 0.0 10 -17.58 -0.1651 0.0 3.750 -0.619 Vel = 9.40 10 3.12 0.874 R 1.0 5.667 16.525 to 150.0 N 7.0 8.000 0.0 13 -14.46 -0.1150 0.0 13.667 -1.572 Vel= 7.73 13 0.0 0.874 2R 2.0 24.250 14.953 to 150.0 0 3.0 5.000 0.0 14 -14.46 -0.1150 0.0 29.250 -3.363 Vel= 7.73 14 0.0 0.874 R 1.0 0.583 11.590 to 150.0 0.0 1.000 0.0 3 -14.46 -0.1150 0.0 1.583 -0.182 Vel= 7.73 0.0 -14.46 11.408 K Factor = -4.28 21 26.20 1.101 R 1.0 11.083 25.671 to 150.0 2N 14.0 20.000 0.0 22 26.2 0.1122 0 5.0 31.083 3.487 Vel= 8.83 22 0.0 1.101 R 1.0 10.750 29.158 to 150.0 N 7.0 13.000 0.0 23 26.2 0.1121 0 5.0 23.750 2.663 Vel = 8.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 11 Final Calculations - Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Page 8 Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 0.0 1.101 N 7.0 3.750 31.821 to 150.0 0.0 7.000 0.0 TRA 26.2 0.1122 0.0 10.750 1.206 Vel= 8.83 0.0 26.20 33.027 K Factor = 4.56 TRA 26.20 1.101 2R 2.0 8.000 33.027 to 150.0 5 9.563 18.562 6.465 * * Fixed Loss = 3 BR 26.2 0.1122 Fsp 0.0 26.562 2.979 Vel= 8.83 N 7.0 BR 5.00 1.101 0 5.0 2.000 42.471 Qa=5 to 150.0 0.0 5.000 0.0 X 31.2 0.1549 0.0 7.000 1.084 Vel= 10.51 X 0.0 1.244 0.0 5.000 43.555 to 150.0 0.0 0.0 2.166 EL 31.2 0.0854 0.0 5.000 0.427 Vel = 8.24 EL 0.0 1.244 0.0 65.000 46.148 to 150.0 0.0 0.0 0.0 Ml 31.2 0.0855 0.0 65.000 5.557 Vel = 8.24 Ml 0.0 1.025 0.0 1.000 51.705 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 31.2 0.2190 0.0 1.000 0.219 Vel = 12.13 M2 0.0 0.995 T 5.841 28.000 55.924 to 150.0 0.0 5.841 0.0 CM 31.2 0.2537 0.0 33.841 8.584 Vel = 12.87 CM -14.09 7.98 3F 40.774 324.000 64.508 to 150.0 T 52.855 93.629 0.0 100 17.11 0.0 0.0 417.629 0.002 Vel = 0.11 100 0.87 7.98 T 52.855 295.000 64.510 to 150.0 0.0 52.855 0.0 101 17.98 0.0 0.0 347.855 0.001 Vel = 0.12 0.0 17.98 64.511 K Factor = 2.24 100 -0.87 7.98 21 105.71 381.000 64.510 to 150.0 0.0 105.710 -1.299 105 -0.87 0.0 0.0 486.710 -0.001 Vel = 0.01 0.0 -0.87 63.210 K Factor = -0.11 101 17.98 11.65 F 17.441 175.000 64.511 to 150.0 1 80.498 97.939 0.0 102 17.98 0.0 0.0 272.939 0.0 Vel = 0.05 102 -31.20 11.65 F 17.441 532.000 64.511 to 150.0 T 80.498 97.939 0.0 103 -13.22 0.0 0.0 629.939 0.0 Vel = 0.04 103 0.0 7.98 T 52.855 542.000 64.511 to 150.0 0.0 52.855 0.0 104 -13.22 0.0 0.0 594.855 -0.001 Vel = 0.08 104 14.09 11.65 T 80.498 207.000 64.510 to 150.0 0.0 80.498 -1.299 105 0.87 0.0 0.0 287.498 -0.001 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Ref. Dia. "C' Fitting or Pipe Ftngs Pt Pt Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 0.87 63.210 K Factor = 0.11 104 -14.09 7.98 T 52.855 542.000 64.510 to 150.0 0.0 52.855 0.0 CM -14.09 0.0 0.0 594.855 -0.002 Vel = 0.09 0.0 -14.09 64.508 K Factor= -1.75 102 31.20 11.65 3T 241.494 1439.000 64.511 to 150.0 0.0 241.494 6.930 FT 31.2 0.0 0.0 1680.494 0.002 Vel = 0.09 0.0 31.20 71.443 K Factor = 3.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS AT THE PRESERVE Building PLAN 2X Location : ALT. CALC AREA 2 System : 1 Contract Data File : ALT. PLAN2X CA2 20X20.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page 1 CYPRESS AT THE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - ALT. CALC AREA 2 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9'-0" OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)l ( )2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 20.024 Psi Required 42.128 At BR Summary C-Factor Used: Overhead 150 Underground 150 Pump Data: Tank or Reservoir: Rated Cap. Cap. 8 Psi Elev. Elev. Other Well Proof Flow Gpm W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 94 R Residual (Psi) - 66 Flow (Gpm) - 3750 S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical Page 2 CYPRESS AT THE PRESERVE Date 5/25/17 City Water Suppiy: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 16.458 C2 - Residual Pressure: 59.4 D2 - System Flow : 20.024 C2 - Residual Flow : 3750 D2 - System Pressure : 65.778 Hose ( Demand) : 5 D3 - System Demand : 25.024 Safety Margin : 18.821 150 140 130 p120 R° E10° 90 C1 S 80 U 70 - C2 R 60D3 E5° 40 30 20 Dl 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name ½ 3/4 1 1 1/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for C Factors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Hi 9.0 24.49 na H2 9.0 24.49 na H3 19.0 4.9 16.7 na 20.02 0.05 400 16.7 H4 19.0 20.98 na H5 19.0 21.83 na H6 29.0 18.05 na H7 29.0 18.09 na Dl 10.0 24.06 na D2 10.0 24.06 na 10.0 24.06 na 2 10.0 24.06 na 3 20.0 19.73 na D3 20.0 17.95 na 4 20.0 18.93 na 5 20.0 19.57 na D4 20.0 20.55 na 6 20.0 20.55 na D5 20.0 21.4 na 7 20.0 21.72 na 8 20.0 21.8 na 15 30.0 17.58 na D6 30.0 17.61 na 16 30.0 17.64 na D7 30.0 17.66 na 17 30.0 17.66 na 18 30.0 17.69 na 19 30.0 17.66 na 20 30.0 17.74 na 9 20.0 22.07 na ii 20.0 22.5 na 12 20.0 23.89 na 10 20.0 22.16 na 13 20.0 21.41 na 14 20.0 19.82 na 21 10.0 29.38 na 22 10.0 31.5 na 23 10.0 33.12 na TRA 10.0 33.85 na BR 2.0 42.13 na 5.0 X 2.0 42.85 na EL -3.0 45.3 na Ml -3.0 48.99 na M2 -3.0 53.14 na CM -3.0 58.84 na 100 -3.0 58.85 na 101 -3.0 58.85 na 102 -3.0 58.85 na 103 -3.0 58.85 na 104 -3.0 58.85 na FT -19.0 65.78 na The maximum velocity is 10.71 and it occurs in the pipe between nodes H3 and D3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 24.494 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 24.061 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 24.494 to 150.0 0.0 3.000 -0.433 D2 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 24.061 K Factor =0 H3 20.02 0.874 N 7.0 1.000 16.700 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D3 20.02 0.2099 0.0 8.000 1.679 Vel = 10.71 0.0 20.02 17.946 K Factor = 4.73 H4 0.0 0.874 N 7.0 1.000 20.984 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 20.551 K Factor = 0 H5 0.0 0.874 0 3.0 1.000 21.832 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 21.399 K Factor = 0 H6 0.0 0.874 N 7.0 1.000 18.045 to 150.0 0.0 7.000 -0.433 D6 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 17.612 K Factor =0 H7 0.0 0.874 N 7.0 1.000 18.089 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 17.656 K Factor = 0 Dl 0.0 0.874 0 3.0 5.583 24.061 to 150.0 0.0 3.000 0.0 1 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 24.061 K Factor = 0 D2 0.0 0.874 R 1.0 8.833 24.061 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vel = 0 1 0.0 0.874 N 7.0 1.917 24.061 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 24.061 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Page Date 6 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. 11C., or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -9.66 0.874 213 2.0 12.750 19.730 to 150.0 0.0 2.000 0.0 4 -9.66 -0.0545 0.0 14.750 -0.804 Vel = 5.17 0.0 -9.66 18.926 K Factor = -2.22 D3 20.02 0.874 0 3.0 1.667 17.946 to 150.0 0.0 3.000 0.0 4 20.02 0.2100 0.0 4.667 0.980 Vel = 10.71 4 -9.66 0.874 N 7.0 3.333 18.926 to 150.0 0.0 7.000 0.0 5 10.36 0.0621 0.0 10.333 0.642 Vel = 5.54 5 0.0 0.874 2R 2.0 10.833 19.568 to 150.0 0 3.0 5.000 0.0 6 10.36 0.0621 0.0 15.833 0.983 Vel = 5.54 0.0 10.36 20.551 K Factor = 2.29 D4 0.0 0.874 N 7.0 9.083 20.551 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vel = 0 6 10.36 0.874 N 7.0 5.667 20.551 to 150.0 R 1.0 8.000 0.0 D5 10.36 0.0620 0.0 13.667 0.848 Vel = 5.54 D5 0.0 0.874 0 3.0 2.250 21-399 to 150.0 0.0 3.000 0.0 7 10.36 0.0621 0.0 5.250 0.326 Vel = 5.54 7 -7.27 0.874 N 7.0 4.667 21.725 to 150.0 0.0 7.000 0.0 8 3.09 0.0066 0.0 11.667 0.077 Vel = 1.65 8 0.0 0.874 N 7.0 10.000 21.802 to 150.0 0.0 7.000 -4.331 15 3.09 0.0066 0.0 17.000 0.112 Vel = 1.65 15 0.0 0.874 R 1.0 3.333 17.583 to 150.0 0.0 1.000 0.0 D6 3.09 0.0067 0.0 4.333 0.029 Vel = 1.65 D6 0.0 0.874 0 3.0 0.583 17.612 to 150.0 0.0 3.000 0.0 16 3.09 0.0067 0.0 3.583 0.024 Vel = 1.65 16 -1.52 0.874 0 3.0 7.583 17.636 to 150.0 0.0 3.000 0.0 17 1.57 0.0019 0.0 10.583 0.020 Vel = 0.84 0.0 1.57 17.656 K Factor = 0.37 D7 0.0 0.874 0 3.0 9.083 17.656 to 150.0 0.0 3.000 0.0 17 0.0 0.0 0.0 12.083 0.0 Vel = 0 17 1.57 0.874 R 1.0 13.500 17.656 to 150.0 0 3.0 4.000 0.0 18 1.57 0.0019 0.0 17.500 0.033 Vel = 0.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftngs Pt Pt Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -3.09 0.874 N 7.0 7.583 17.689 to 150.0 0.0 7.000 0.0 19 -1.52 -0.0018 0.0 14.583 -0.026 Vel = 0.81 19 0.0 0.874 2R 2.0 13.500 17.663 to 150.0 0.0 2.000 0.0 16 -1.52 -0.0017 0.0 15.500 -0.027 Vel = 0.81 0.0 -1.52 17.636 K Factor = -0.36 18 3.09 0.874 N 7.0 0.500 17.689 to 150.0 0.0 7.000 0.0 20 3.09 0.0065 0.0 7.500 0.049 Vel = 1.65 20 0.0 0.874 0 3.0 10.000 17.738 to 150.0 0.0 3.000 4.331 10 3.09 0.0066 0.0 13.000 0.086 Vel = 1.65 0.0 3.09 22.155 K Factor = 0.66 7 7.28 0.874 0 3.0 7.583 21.725 to 150.0 0.0 3.000 0.0 9 7.28 0.0322 0.0 10.583 0.341 Vel = 3.89 9 0.0 0.874 0 3.0 10.333 22.066 to 150.0 0.0 3.000 0.0 11 7.28 0.0323 0.0 13.333 0.431 Vel = 3.89 11 12.74 1.101 2N 14.0 6.417 22.497 to 150.0 0.0 14.000 0.0 12 20.02 0.0682 0.0 20.417 1.392 Vel = 6.75 12 0.0 1.101 N 7.0 10.000 23.889 to 150.0 0.0 7.000 4.331 21 20.02 0.0682 0.0 17.000 1.159 Vel = 6.75 0.0 20.02 29.379 K Factor = 3.69 11 -12.75 0.874 R 1.0 2.750 22.497 to 150.0 0.0 1.000 0.0 10 -12.75 -0.0912 0.0 3.750 -0.342 Vel = 6.82 10 3.09 0.874 R 1.0 5.667 22.155 to 150.0 N 7.0 8.000 0.0 13 -9.66 -0.0545 0.0 13.667 -0.745 Vel = 5.17 13 0.0 0.874 2R 2.0 24.250 21.410 to 150.0 0 3.0 5.000 0.0 14 -9.66 -0.0545 0.0 29.250 -1.594 Vel = 5.17 14 0.0 0.874 R 1.0 0.583 19.816 to 150.0 0.0 1.000 0.0 3 -9.66 -0.0543 0.0 1.583 -0.086 Vel = 5.17 0.0 -9.66 19.730 K Factor= -2.17 21 20.02 1.101 R 1.0 11.083 29.379 to 150.0 2N 14.0 20.000 0.0 22 20.02 0.0682 0 5.0 31.083 2.120 Vel = 6.75 22 0.0 1.101 R 1.0 10.750 31.499 to 150.0 N 7.0 13.000 0.0 23 20.02 0.0682 0 5.0 23.750 1.619 Vel = 6.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C',or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 0.0 1.101 N 7.0 3.750 33.118 to 150.0 0.0 7.000 0.0 TRA 20.02 0.0683 0.0 10.750 0.734 Vet = 6.75 0.0 20.02 33.852 K Factor = 3.44 TRA 20.02 1.101 2R 2.0 8.000 33.852 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 20.02 0.0682 Fsp 0.0 26.562 1.811 Vel = 6.75 N 7.0 BR 5.00 1.101 0 5.0 2.000 42.128 Qa=5 to 150.0 0.0 5.000 0.0 X 25.02 0.1030 0.0 7.000 0.721 Vel = 8.43 X 0.0 1.244 0.0 5.000 42.849 to 150.0 0.0 0.0 2.166 EL 25.02 0.0566 0.0 5.000 0.283 Vel = 6.60 EL 0.0 1.244 0.0 65.000 45.298 to 150.0 0.0 0.0 0.0 Ml 25.02 0.0568 0.0 65.000 3.694 Vel = 6.60 Ml 0.0 1.025 0.0 1.000 48.992 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 25.02 0.1460 0.0 1.000 0.146 Vel = 9.73 M2 0.0 0.995 T 5.841 28.000 53.138 to 150.0 0.0 5.841 0.0 CM 25.02 0.1686 0.0 33.841 5.707 Vel = 10.32 CM -11.30 7.98 3F 40.774 324.000 58.845 to 150.0 T 52.855 93.629 0.0 100 13.72 0.0 0.0 417.629 0.001 Vel = 0.09 100 0.70 7.98 T 52.855 295.000 58.846 to 150.0 0.0 52.855 0.0 101 14.42 0.0 0.0 347.855 0.0 Vel = 0.09 0.0 14.42 58.846 K Factor = 1.88 100 -0.70 7.98 2T 105.71 381.000 58.846 to 150.0 0.0 105.710 -1.299 105 -0.7 0.0 0.0 486.710 -0.001 Vet = 0 0.0 -0.70 57.546 K Factor = -0.09 101 14.42 11.65 F 17.441 175.000 58.846 to 150.0 T 80.498 97.939 0.0 102 14.42 0.0 0.0 272.939 0.001 Vel = 0.04 102 -25.02 11.65 F 17.441 532.000 58.847 to 150.0 1 80.498 97.939 0.0 103 -10.6 0.0 0.0 629.939 -0.001 Vel = 0.03 103 0.0 7.98 1 52.855 542.000 58.846 to 150.0 0.0 52.855 0.0 104 -10.6 0.0 0.0 594.855 0.0 Vel = 0.07 104 11.30 11.65 1 80.498 207.000 58.846 to 150.0 0.0 80.498 -1.299 105 0.7 0.0 0.0 287.498 -0.001 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Ref. Dia. "C" Fitting or Pipe Ftngs Pt Pt Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 0.70 57.546 K Factor = 0.09 104 -11.30 7.98 T 52.855 542.000 58.846 to 150.0 0.0 52.855 0.0 CM -11.3 0.0 0.0 594.855 -0.001 Vel = 0.07 0.0 -11.30 58.845 K Factor = -1.47 102 25.02 11.65 3T 241.494 1439.000 58.847 to 150.0 0.0 241.494 6.930 FT 25.02 0.0 0.0 1680.494 0.001 Vel = 0.08 0.0 25.02 65.778 K Factor = 3.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS ATTHE PRESERVE Building : PLAN 2X Location : ALT. CALC AREA 3 System 1 Contract Data File : ALT. PLAN2X CA3 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page 1 CYPRESS AT THE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - ALT. CALC AREA 3 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9'-0" OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 27.827 Psi Required 39.642 At BR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - 8 Psi Elev. E Static (Psi) - 94 Elev. R Residual (Psi) - 66 Other Well Flow (Gpm) - 3750 Proof Flow Gpm S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE Page 2 Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 16.458 C2 - Residual Pressure: 59.4 D2 - System Flow : 27.827 C2 - Residual Flow : 3750 D2 - System Pressure : 70.176 Hose ( Demand) : 5 D3 - System Demand : 32.827 Safety Margin : 14.423 150 140 130 p120 R° E10° 90 C1 80 u 70 - - C2 R 601133 E5° 40 30 20 Dl 10 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name ½ 3/4 1 1¼ 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per N EPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea- H1 9.0 15.26 na H2 9.0 15.26 na H3 19.0 10.38 na H4 19.0 4.9 7.04 na 13.0 0.05 H5 19.0 4.9 9.16 na 14.83 0.05 H6 29.0 7.34 na H7 29.0 7.53 na Dl 10.0 14.83 na D2 10.0 14.83 na 1 10.0 14.83 na 2 10.0 14.83 na 3 20.0 10.5 na D3 20.0 9.95 na 4 20.0 9.95 na 5 20.0 9.56 na D4 20.0 7.36 na 6 20.0 8.97 na D5 20.0 9.2 na 7 20.0 10.3 na 8 20.0 10.63 na 15 30.0 6.79 na D6 30.0 6.91 na 16 30.0 7.01 na D7 30.0 7.1 na 17 30.0 7.1 na 18 30.0 7.24 na 19 30.0 7.13 na 20 30.0 7.46 na 9 20.0 11.32 na ii 20.0 12.6 na 12 20.0 15.16 na 10 20.0 12.16 na 13 20.0 11.65 na 14 20.0 10.56 na 21 10.0 21.63 na 22 10.0 25.52 na 23 10.0 28.5 na TRA 10.0 29.85 na BR 2.0 39.64 na 5.0 X 2.0 40.83 na EL -3.0 43.47 na Mi -3.0 49.57 na M2 -3.0 53.81 na CM -3.0 63.24 na 100 -3.0 63.24 na 101 -3.0 63.24 na 102 -3.0 63.24 na 103 -3.0 63.24 na 104 -3.0 63.24 na FT -19.0 70.18 na The maximum velocity is 13.55 and it occurs in the pipe between nodes M2 and CM Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 256 7.039 256 7.0 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftngs Pe Pv ******* Notes Point Qt Pt/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 15.265 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 14.832 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 15.265 to 150.0 0.0 3.000 -0.433 D2 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 14.832 K Factor =0 H3 0.0 0.874 N 7.0 1.000 10.383 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 9.950 K Factor = 0 H4 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D4 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 K Factor = 4.79 H5 14.83 0.874 0 3.0 1.000 9.156 K Factor = 4.90 to 150.0 0.0 3.000 -0.433 D5 14.83 0.1205 0.0 4.000 0.482 Vel = 7.93 0.0 14.83 9.205 K Factor = 4.89 H6 0.0 0.874 N 7.0 1.000 7.345 to 150.0 0.0 7.000 -0.433 D6 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 6.912 K Factor =0 H7 0.0 0.874 N 7.0 1.000 7.534 to 150.0 0.0 7.000 -0.433 D7 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 7.101 K Factor = 0 Di 0.0 0.874 0 3.0 5.583 14.832 to 150.0 0.0 3.000 0.0 1 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 14.832 K Factor = 0 D2 0.0 0.874 R 1.0 8.833 14.832 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vel = 0 1 0.0 0.874 N 7.0 1.917 14.832 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 14.832 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -7.87 0.874 2R 2.0 12.750 10.501 to 150.0 0.0 2.000 0.0 4 -7.87 -0.0374 0.0 14.750 -0.551 Vel = 4.21 0.0 -7.87 9.950 K Factor = -2.49 D3 0.0 0.874 0 3.0 1.667 9.950 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vet = 0 4 -7.87 0.874 N 7.0 3.333 9.950 to 150.0 0.0 7.000 0.0 5 -7.87 -0.0373 0.0 10.333 -0.385 Vel = 4.21 5 0.0 0.874 2R 2.0 10.833 9.565 to 150.0 0 3.0 5.000 0.0 6 -7.87 -0.0373 0.0 15.833 -0.591 Vet = 4.21 0.0 -7.87 8.974 K Factor = -2.63 D4 13.00 0.874 N 7.0 9.083 7.361 to 150.0 R 1.0 8.000 0.0 6 13.0 0.0944 0.0 17.083 1.613 Vet = 6.95 6 -7.87 0.874 N 7.0 5.667 8.974 to 150.0 R 1.0 8.000 0.0 D5 5.13 0.0169 0.0 13.667 0.231 Vel = 2.74 D5 14.83 0.874 0 3.0 2.250 9.205 to 150.0 0.0 3.000 0.0 7 19.96 0.2086 0.0 5.250 1.095 Vel = 10.67 7 -13.15 0.874 N 7.0 4.667 10.300 to 150.0 0.0 7.000 0.0 8 6.81 0.0286 0.0 11.667 0.334 Vet = 3.64 8 0.0 0.874 N 7.0 10.000 10.634 to 150.0 0.0 7.000 -4.331 15 6.81 0.0285 0.0 17.000 0.485 Vet = 3.64 15 0.0 0.874 R 1.0 3.333 6.788 to 150.0 0.0 1.000 0.0 D6 6.81 0.0286 0.0 4.333 0.124 Vet = 3.64 D6 0.0 0.874 0 3.0 0.583 6.912 to 150.0 0.0 3.000 0.0 16 6.81 0.0285 0.0 3.583 0.102 Vel = 3.64 16 -3.34 0.874 0 3.0 7.583 7.014 to 150.0 0.0 3.000 0.0 17 3.47 0.0082 0.0 10.583 0.087 Vel = 1.86 0.0 3.47 7.101 K Factor = 1.30 D7 0.0 0.874 0 3.0 9.083 7.101 to 150.0 0.0 3.000 0.0 17 0.0 0.0 0.0 12.083 0.0 Vel = 0 17 3.47 0.874 R 1.0 13.500 7.101 to 150.0 0 3.0 4.000 0.0 18 3.47 0.0082 0.0 17.500 0.143 Vel= 1.86 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. "C',or Fitting Pipe Ftng's Pt Pt Pe Pv Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 18 -6.81 0.874 N 7.0 7.583 7.244 to 150.0 0.0 7.000 0.0 19 -3.34 -0.0076 0.0 14.583 -0.111 Vel= 1.79 19 0.0 0.874 2R 2.0 13.500 7.133 to 150.0 0.0 2.000 0.0 16 -3.34 -0.0077 0.0 15.500 -0.119 Vel= 1.79 0.0 -3.34 7.014 K Factor = -1.26 18 6.81 0.874 N 7.0 0.500 7.244 to 150.0 0.0 7.000 0.0 20 6.81 0.0287 0.0 7.500 0.215 Vel = 3.64 20 0.0 0.874 0 3.0 10.000 7.459 to 150.0 0.0 3.000 4.331 10 6.81 0.0285 0.0 13.000 0.371 Vel = 3.64 0.0 6.81 12.161 K Factor = 1.95 7 13.14 0.874 0 3.0 7.583 10.300 to 150.0 0.0 3.000 0.0 9 13.14 0.0964 0.0 10.583 1.020 VeI= 7.03 9 0.0 0.874 0 3.0 10.333 11.320 to 150.0 0.0 3.000 0.0 11 13.14 0.0963 0.0 13.333 1.284 VeI= 7.03 11 14.69 1.101 2N 14.0 6.417 12.604 to 150.0 0.0 14.000 0.0 12 27.83 0.1254 0.0 20.417 2.560 Vel = 9.38 12 0.0 1.101 N 7.0 10.000 15.164 to 150.0 0.0 7.000 4.331 21 27.83 0.1254 0.0 17.000 2.131 Vel = 9.38 0.0 27.83 21.626 KFactor= 5.98 11 -14.68 0.874 R 1.0 2.750 12.604 to 150.0 0.0 1.000 0.0 10 -14.68 -0.1181 0.0 3.750 -0.443 Vel = 7.85 10 6.81 0.874 R 1.0 5.667 12.161 to 150.0 N 7.0 8.000 0.0 13 -7.87 -0.0373 0.0 13.667 -0.510 Vet = 4.21 13 0.0 0.874 2R 2.0 24.250 11.651 to 150.0 0 3.0 5.000 0.0 14 -7.87 -0.0373 0.0 29.250 -1.091 Vel= 4.21 14 0.0 0.874 R 1.0 0.583 10.560 to 150.0 0.0 1.000 0.0 3 -7.87 -0.0373 0.0 1.583 -0.059 Vel = 4.21 0.0 -7.87 10.501 K Factor = -2.43 21 27.83 1.101 R 1.0 11.083 21.626 to 150.0 2N 14.0 20.000 0.0 22 27.83 0.1253 0 5.0 31.083 3.896 Vel = 9.38 22 0.0 1.101 R 1.0 10.750 25.522 to 150.0 N 7.0 13.000 0.0 23 27.83 0.1254 0 5.0 23.750 2.978 Vel = 9.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 0.0 1.101 N 7.0 3.750 28.500 to 150.0 0.0 7.000 0.0 TRA 27.83 0.1253 0.0 10.750 1.347 Vel = 9.38 0.0 27.83 29.847 K Factor = 5.09 TRA 27.83 1.101 2R 2.0 8.000 29.847 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 27.83 0.1254 Fsp 0.0 26.562 3.330 Vel = 9.38 N 7.0 BR 5.00 1.101 0 5.0 2.000 39.642 Qa=5 to 150.0 0.0 5.000 0.0 X 32.83 0.1701 0.0 7.000 1.191 Vei= 11.06 X 0.0 1.244 0.0 5.000 40.833 to 150.0 0.0 0.0 2.166 EL 32.83 0.0938 0.0 5.000 0.469 Vel = 8.67 EL 0.0 1.244 0.0 65.000 43.468 to 150.0 0.0 0.0 0.0 Ml 32.83 0.0939 0.0 65.000 6.103 Vel = 8.67 Ml 0.0 1.025 0.0 1.000 49.571 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 32.83 0.2410 0.0 1.000 0.241 Vel= 12.76 M2 0.0 0.995 T 5.841 28.000 53.812 to 150.0 0.0 5.841 0.0 CM 32.83 0.2786 0.0 33.841 9.429 Vel = 13.55 CM -14.83 7.98 3F 40.774 324.000 63.241 to 150.0 T 52.855 93.629 0.0 100 18.0 0.0 0.0 417.629 0.001 Vel = 0.12 100 0.92 7.98 T 52.855 295.000 63.242 to 150.0 0.0 52.855 0.0 101 18.92 0.0 0.0 347.855 0.001 Vel = 0.12 0.0 18.92 63.243 K Factor = 2.38 100 -0.92 7.98 21 105.71 381.000 63.242 to 150.0 0.0 105.710 -1.299 105 -0.92 0.0 0.0 486.710 0.0 Vel = 0.01 0.0 -0.92 61.943 K Factor = -0.12 101 18.92 11.65 F 17.441 175.000 63.243 to 150.0 T 80.498 97.939 0.0 102 18.92 0.0 0.0 272.939 0.001 Vel = 0.06 102 -32.83 11.65 F 17.441 532.000 63.244 to 150.0 T 80.498 97.939 0.0 103 -13.91 0.0 0.0 629.939 -0.001 Vel = 0.04 103 0.0 7.98 T 52.855 542.000 63.243 to 150.0 0.0 52.855 0.0 104 -13.91 0.0 0.0 594.855 -0.001 Vel = 0.09 104 14.83 11.65 1 80.498 207.000 63.242 to 150.0 0.0 80.498 -1.299 105 0.92 0.0 0.0 287.498 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Ref. Dia. "C" Fitting or Pipe Ftngs Pt Pt Fe Pv Notes Point Qt Pt/Ft Eqv. Ln. Total Pt Pn 0.0 0.92 61.943 KFactor= 0.12 104 -14.83 7.98 T 52.855 542.000 63.242 to 150.0 0.0 52.855 0.0 CM -14.83 0.0 0.0 594.855 -0.001 Vel = 0.10 0.0 -14.83 63.241 K Factor = -1.86 102 32.83 11.65 31 241.494 1439.000 63.244 to 150.0 0.0 241.494 6.930 FT 32.83 0.0 0.0 1680.494 0.002 Vel = 0.10 0.0 32.83 70.176 K Factor = 3.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 Job Name : CYPRESS AT THE PRESERVE Building PLAN 2X Location : ALT. CALC AREA 4 System : 1 Contract Data File : ALT. PLAN2X CA4 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical Page 1 CYPRESS AT THE PRESERVE Date 5/25/17 HYDRAULIC DESIGN INFORMATION SHEET Name - CYPRESS AT THE PRESERVE Date - 5/25/17 Location - ALT. CALC AREA 4 Building - PLAN 2X System No. - 1 Contractor - NP MECHANICAL Contract No. - Calculated By - MG Drawing No. - 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9'-0" OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RFC49 I Elevation at Highest Outlet - Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 165 N Calculation Gpm Required 27.01 Psi Required 42.981 At BR Summary C-Factor Used: Overhead 150 Underground 150 Pump Data: Tank or Reservoir: Rated Cap. Cap. 8 Psi Elev. Elev. Other Well Proof Flow Gpm W Water Flow Test: A Date of Test - T Time of Test - B Static (Psi) - 94 R Residual (Psi) - 66 Flow (Gpm) - 3750 S Elevation - 114 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE Page 2 Date 5/25/17 City Water Supply: Demand: Cl - Static Pressure : 84.6 Dl - Elevation : 20.789 C2 - Residual Pressure: 59.4 D2 - System Flow :27.01 C2 - Residual Flow : 3750 D2 - System Pressure : 72.721 Hose ( Demand) : 5 D3 - System Demand : 32.01 Safety Margin : 11.878 150 140 130 p120 R11° E10° s90 C S D2 80 U 70 D3 R 60 E5° 40 30 20 DT 10 I I I I I I I 400 800 1200 1600 2000 2400 2800 3200 3600 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary NP Mechanical Page 3 CYPRESS AT THE PRESERVE Date 5/25/17 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplinglee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 9.0 20.71 na 9.0 20.71 na 19.0 16.3 na 19.0 16.16 na 19.0 16.08 na 29.0 4.9 8.17 na 29.0 4.9 7.04 na 10.0 20.27 na 10.0 20.27 na 10.0 20.27 na 10.0 20.27 na 20.0 15.94 na 20.0 15.86 na 20.0 15.86 na 20.0 15.81 na 20.0 15.72 na 20.0 15.72 na 20.0 15.65 na 20.0 15.62 na 20.0 14.67 na 30.0 8.96 na 30.0 8.61 na 30.0 8.62 na 30.0 7.36 na 30.0 8.5 na 30.0 9.32 na 30.0 8.98 na 30.0 10.25 na 20.0 16.15 na 20.0 16.82 na 20.0 19.24 na 20.0 16.18 na 20.0 16.11 na 20.0 15.95 na 10.0 25.59 na 10.0 29.27 na 10.0 32.09 na 10.0 33.37 na 2.0 42.98 na 2.0 44.12 na -3.0 46.73 na -3.0 52.56 na -3.0 56.79 na -3.0 65.79 na -3.0 65.79 na -3.0 65.79 na -3.0 65.79 na -3.0 65.79 na -3.0 65.79 na -19.0 72.72 na 14.01 0.05 256 7.0 13.0 0.05 256 7.039 5.0 Pressure I Flow Summary - STANDARD NP Mechanical Page 4 CYPRESS ATTHE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. The maximum velocity is 13.21 and it occurs in the pipe between nodes M2 and CM Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 5 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 20.708 to 150.0 0.0 7.000 -0.433 Di 0.0 -0.0001 0.0 8.000 -0.001 Vel = 0 0.0 0.0 20.274 K Factor = 0 H2 0.0 0.874 0 3.0 1.000 20.708 to 150.0 0.0 3.000 -0.433 D2 0.0 -0.0002 0.0 4.000 -0.001 Vel = 0 0.0 0.0 20.274 K Factor =0 H3 0.0 0.874 N 7.0 1.000 16.297 to 150.0 0.0 7.000 -0.433 D3 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 15.864 K Factor = 0 H4 0.0 0.874 N 7.0 1.000 16.156 to 150.0 0.0 7.000 -0.433 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 15.723 K Factor =0 H5 0.0 0.874 0 3.0 1.000 16.082 to 150.0 0.0 3.000 -0.433 D5 0.0 0.0 0.0 4.000 0.0 Vel = 0 0.0 0.0 15.649 K Factor = 0 H6 14.01 0.874 N 7.0 1.000 8.175 K Factor =4.90 to 150.0 0.0 7.000 -0.433 D6 14.01 0.1084 0.0 8.000 0.867 Vel = 7.49 0.0 14.01 8.609 K Factor = 4.77 H7 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D7 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 K Factor = 4.79 Di 0.0 0.874 0 3.0 5.583 20.274 to 150.0 0.0 3.000 0.0 0.0 0.0 0.0 8.583 0.0 Vel = 0 0.0 0.0 20.274 K Factor = 0 D2 0.0 0.874 R 1.0 8.833 20.274 to 150.0 0.0 1.000 0.0 1 0.0 0.0 0.0 9.833 0.0 Vel = 0 0.0 0.874 N 7.0 1.917 20.274 to 150.0 0.0 7.000 0.0 2 0.0 0.0 0.0 8.917 0.0 Vel = 0 2 0.0 0.874 0 3.0 10.000 20.274 to 150.0 0.0 3.000 -4.331 3 0.0 0.0 0.0 13.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 6 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Oa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 3 -2.77 0.874 2R 2.0 12.750 15.943 to 150.0 0.0 2.000 0.0 4 -2.77 -0.0054 0.0 14.750 -0.079 Vel = 1.48 0.0 -2.77 15.864 K Factor = -0.70 D3 0.0 0.874 0 3.0 1.667 15.864 to 150.0 0.0 3.000 0.0 4 0.0 0.0 0.0 4.667 0.0 Vel = 0 4 -2.77 0.874 N 7.0 3.333 15.864 to 150.0 0.0 7.000 0.0 5 -2.77 -0.0054 0.0 10.333 -0.056 Vel = 1.48 5 0.0 0.874 2R 2.0 10.833 15.808 to 150.0 0 3.0 5.000 0.0 6 -2.77 -0.0054 0.0 15.833 -0.085 Vel = 1.48 0.0 -2.77 15.723 K Factor = -0.70 D4 0.0 0.874 N 7.0 9.083 15.723 to 150.0 R 1.0 8.000 0.0 6 0.0 0.0 0.0 17.083 0.0 Vel = 0 6 -2.77 0.874 N 7.0 5.667 15.723 to 150.0 R 1.0 8.000 0.0 D5 -2.77 -0.0054 0.0 13.667 -0.074 Vel= 1.48 D5 0.0 0.874 0 3.0 2.250 15.649 to 150.0 0.0 3.000 0.0 7 -2.77 -0.0053 0.0 5.250 -0.028 Vel = 1.48 7 -9.22 0.874 N 7.0 4.667 15.621 to 150.0 0.0 7.000 0.0 8 -11.99 -0.0813 0.0 11.667 -0.948 Vel= 6.41 8 0.0 0.874 N 7.0 10.000 14.673 to 150.0 0.0 7.000 -4.331 15 -11.99 -0.0812 0.0 17.000 -1.381 Vel = 6.41 15 0.0 0.874 R 1.0 3.333 8.961 to 150.0 0.0 1.000 0.0 D6 -11.99 -0.0812 0.0 4.333 -0.352 Vel= 6.41 D6 14.01 0.874 0 3.0 0.583 8.609 to 150.0 0.0 3.000 0.0 16 2.02 0.0031 0.0 3.583 0.011 Vel= 1.08 16 -6.11 0.874 0 3.0 7.583 8.620 to 150.0 0.0 3.000 0.0 17 -4.09 -0.0111 0.0 10.583 -0.118 Vel = 2.19 0.0 -4.09 8.502 K Factor = -1.40 D7 13.00 0.874 0 3.0 9.083 7.361 to 150.0 0.0 3.000 0.0 17 13.0 0.0944 0.0 12.083 1.141 Vel = 6.95 17 -4.09 0.874 R 1.0 13.500 8.502 to 150.0 0 3.0 4.000 0.0 18 8.91 0.0469 0.0 17.500 0.821 Vel = 4.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 7 CYPRESS ATTHE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. 'C' Fitting or Pipe Ftng's Pt Pt Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -15.02 0.874 N 7.0 7.583 9.323 to 150.0 0.0 7.000 0.0 19 -6.11 -0.0234 0.0 14.583 -0.341 Vel= 3.27 19 0.0 0.874 2R 2.0 13.500 8.982 to 150.0 0.0 2.000 0.0 16 -6.11 -0.0234 0.0 15.500 -0.362 Vel = 3.27 0.0 -6.11 8.620 K Factor = -2.08 18 15.02 0.874 N 7.0 0.500 9.323 to 150.0 0.0 7.000 0.0 20 15.02 0.1233 0.0 7.500 0.925 Vel = 8.03 20 0.0 0.874 0 3.0 10.000 10.248 to 150.0 0.0 3.000 4.331 10 15.02 0.1234 0.0 13.000 1.604 Vel= 8.03 0.0 15.02 16.183 K Factor = 3.73 7 9.22 0.874 0 3.0 7.583 15.621 to 150.0 0.0 3.000 0.0 9 9.22 0.0500 0.0 10.583 0.529 Vel = 4.93 9 0.0 0.874 0 3.0 10.333 16.150 to 150.0 0.0 3.000 0.0 11 9.22 0.0500 0.0 13.333 0.666 Vel = 4.93 11 17.79 1.101 2N 14.0 6.417 16.816 to 150.0 0.0 14.000 0.0 12 27.01 0.1186 0.0 20.417 2.422 Vel= 9.10 12 0.0 1.101 N 7.0 10.000 19.238 to 150.0 0.0 7.000 4.331 21 27.01 0.1186 0.0 17.000 2.017 Vel= 9.10 0.0 27.01 25.586 K Factor = 5.34 11 -17.79 0.874 R 1.0 2.750 16.816 to 150.0 0.0 1.000 0.0 10 -17.79 -0.1688 0.0 3.750 -0.633 Vel = 9.51 10 15.02 0.874 R 1.0 5.667 16.183 to 150.0 N 7.0 8.000 0.0 13 -2.77 -0.0053 0.0 13.667 -0.073 Vel = 1.48 13 0.0 0.874 2R 2.0 24.250 16.110 to 150.0 0 3.0 5.000 0.0 14 -2.77 -0.0054 0.0 29.250 -0.158 Vel = 1.48 14 0.0 0.874 R 1.0 0.583 15.952 to 150.0 0.0 1.000 0.0 3 -2.77 -0.0057 0.0 1.583 -0.009 Vel = 1.48 0.0 -2.77 15.943 K Factor = -0.69 21 27.01 1.101 R 1.0 11.083 25.586 to 150.0 2N 14.0 20.000 0.0 22 27.01 0.1186 0 5.0 31.083 3.687 Vel= 9.10 22 0.0 1.101 R 1.0 10.750 29.273 to 150.0 N 7.0 13.000 0.0 23 27.01 0.1186 0 5.0 23.750 2.817 Vel = 9.10 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 8 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 0.0 1.101 N 7.0 3.750 32.090 to 150.0 0.0 7.000 0.0 TRA 27.01 0.1187 0.0 10.750 1.276 Vet = 9.10 0.0 27.01 33.366 K Factor = 4.68 TRA 27.01 1.101 2R 2.0 8.000 33.366 to 150.0 S 9.563 18.562 6.465 * * Fixed Loss = 3 BR 27.01 0.1186 Fsp 0.0 26.562 3.150 Vet= 9.10 N 7.0 BR 5.00 1.101 0 5.0 2.000 42.981 Qa=5 to 150.0 0.0 5.000 0.0 X 32.01 0.1624 0.0 7.000 1.137 Vet = 10.79 X 0.0 1.244 0.0 5.000 44.118 to 150.0 0.0 0.0 2.166 EL 32.01 0.0896 0.0 5.000 0.448 Vet = 8.45 EL 0.0 1.244 0.0 65.000 46.732 to 150.0 0.0 0.0 0.0 Ml 32.01 0.0896 0.0 65.000 5.825 Vet = 8.45 Ml 0.0 1.025 0.0 1.000 52.557 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 M2 32.01 0.2300 0.0 1.000 0.230 Vet= 12.45 M2 0.0 0.995 T 5.841 28.000 56.787 to 150.0 0.0 5.841 0.0 CM 32.01 0.2659 0.0 33.841 8.999 Vet = 13.21 CM -14.46 7.98 3F 40.774 324.000 65.786 to 150.0 T 52.855 93.629 0.0 100 17.55 0.0 0.0 417.629 0.001 Vet= 0.11 100 0.90 7.98 T 52.855 295.000 65.787 to 150.0 0.0 52.855 0.0 101 18.45 0.0 0.0 347.855 0.002 Vet = 0.12 0.0 18.45 65.789 K Factor = 2.27 100 -0.90 7.98 2T 105.71 381.000 65.787 to 150.0 0.0 105.710 -1.299 105 -0.9 0.0 0.0 486.710 0.0 Vet = 0.01 0.0 -0.90 64.488 K Factor = -0.11 101 18.45 11.65 F 17.441 175.000 65.789 to 150.0 T 80.498 97.939 0.0 102 18.45 0.0 0.0 272.939 0.0 Vet = 0.06 102 -32.01 11.65 F 17.441 532.000 65.789 to 150.0 T 80.498 97.939 0.0 103 -13.56 0.0 0.0 629.939 -0.001 Vet = 0.04 103 0.0 7.98 T 52.855 542.000 65.788 to 150.0 0.0 52.855 0.0 104 -13.56 0.0 0.0 594.855 -0.001 Vet = 0.09 104 14.46 11.65 T 80.498 207.000 65.787 to 150.0 0.0 80.498 -1.299 105 0.9 0.0 0.0 287.498 0.0 Vet = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams NP Mechanical Page 9 CYPRESS AT THE PRESERVE Date 5/25/17 Hyd. Ref. Qa Dia. I.G.or Fitting Pipe Ftngs Pt Pt Pe Pv Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn 0.0 0.90 64.488 KFactor= 0.11 104 -14.46 7.98 T 52.855 542.000 65.787 to 150.0 0.0 52.855 0.0 CM -14.46 0.0 0.0 594.855 -0.001 Vel = 0.09 0.0 -14.46 65.786 K Factor = -1.78 102 32.01 11.65 3T 241.494 1439.000 65.789 to 150.0 0.0 241.494 6.930 FT 32.01 0.0 0.0 1680.494 0.002 Vel = 0.10 0.0 32.01 72.721 K Factor = 3.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Reliable Bulletin 006 Rev Model RFC30 (SIN RA0611) Model RFC43 (SIN RA0612) Model RFC49 (SIN RA0616) Residential Flat Concealed Sprinklers co C (t 0 0 0) I CD A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpmlft2 with low GPM requirements. Features Very low water flow requirements. Cover plate attachment (Plain or Perforated) with ½" (13mm) Total adjustment. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprin- kler patterns. The combination of speed of operation and high dis- charge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacu- ation time for occupants. The RFC30, RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive ap- pearance and ½" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily main Uover Mate Perforated Cover Plate and positively attached and blends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. The RFC30, RFC43 and RFC49 are UL Listed Residen- tial Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 130. The RFC30, RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit ac- curately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- lations, use a 165°F (74°C) fusible solder link in a tun- ing fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classifica- tion solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the de- flector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler de- flector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The resi- dential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces sig- nificantly higher wall wetting. After a 2'/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexago- nal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe instal- lation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprin- kler/cup assembly, care should be taken to prevent dam- age to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COV- ERS. Note: A leak tight ½" NPT (191/2) sprinkler joint can be ob- tained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Cover assemblies provide up to 1/2" (13mm) of adjust- ment. Turn the cover clockwise until the flange is in con- tact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final ad- justment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover re- moval requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or neg- ative pressurization but must not be positively pres- surized. Inspect all sprinklers after installation to en- sure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Thread Nominal Sprinkler CCP Assembly Max. Ambient K Max. Model (SIN) Size Orifice Temp Rating Temp. Rating Temp. Factor Pressure Inch (mm) Inch (mm) psi (bar) °F °C °F °C °F °C RFC 30 ½" (15) 21/64 (8,2) 165 74 (RA0611) 135 57 100 38 3.0 (43.2) 175 (12) RFC 43 ½"(15) /8(10) 165 74 (RA0612) 135 57 100 38 4.3(62) 175 (12) RFC 49 (RA0616) 1/2" (15) /16(11) 165 74 135 57 100 38 4.9 (70.6) 175 (12) Note: 1 bar = 100 Kpa RFC 30 Ordinary Temp. Rating Max. Coverage Max. Spacing (165°F174°C) T op of Deflector Installation Minimum area Ft x Ft (m x m) Ft (m) to Ceiling Inch (mm) Type Spacing Ft (m) Flow Pressure GPM (Lfmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0 (0,62) Smooth Ceilings 1/2 to 1(13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) 13 installed in beams ½ to 1(13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 130 Fri RFC43 Ordinary Temp. Rating Max. Coverage Max. Spacing (1 65-17174-C) To p of Deflector Installation Minimum area Ft x Ft (m x m) Ft (m) to Ceiling Inch (mm) Te Type Spacing Ft (m) Flow Pressure GPM (L/min) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) Smooth Ceilings 1/2 to 1(13 to 25.4) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams ½ to 1(13 to 25.4) Concealed 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20x20(6,1 x6,1) 20(6,1) 21(79) 23.8 (1,64) For Ceiling types refer to NFPA 13, 13R or 130 RFC49 Max. Coverage Max. Spacing Ordinary Temp. Rating (165°Ff74°C) Top of Deflector Installation Minimum area Ft x Ft (m x m) Ft (m) to Ceiling Inch (mm) Te yp Spacing Ft (m) Flow Pressure GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0 (0,48) 16 x 16(4,9 x 4,9) 16(4,9) 13 (49) 7.0(0,48) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams ½ to 1(13 to 25.4) Concealed 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12.0 (0,83) 20x20(6,1x6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 130 Maintenance. Model RFC30, RFC43 and RFC49 Concealed Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Model RFC30, RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential con- cealed sprinklers with drop-down deflector and adjust- able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K- factor shall be nominal 3.0 (43.2), 4.3 (62), and 4.9 (70.6) having a'/16", /" and 7/16" orifice. Temperature rating shall be Ordinary 165°F (74°C); cover plate temperature rating to be 135°F (571C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a ½" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from dam- age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA061 1 (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). 3. Ordering Information Specify: 1, Sprinkler Model Cover Plate Finish Thread-On or Push-On Feature Cover Plate Finishes 1t Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. x I/2 REDUCING TEE OR ELBOW II, - III 1Tr 2 (66.55mm] .4 (58.42mm] DL4 IJ ] HOLE IN CEiLING _____ _••1 cup , [50.8mm] MAX. I 2 F FITTING ACE OF [12.70mm] MAX.______ FACE OF CEILING COVER A WUSThIENT 1-+ DIMENSION --;:E1i-•i;;;ii______ . 1/2(12.70mm] 1 (25.4mm] DROPPED DEFLECTOR 70 CEILING FLAT COVER MTE . t8421mm DM 46mm ASSEMBLY COVER PLATE: 1/2" [12.7mm] ADJUSTMENT QO6,VOIC The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the Natioral Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are ins-aIled and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliabid (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Primed in U.S.A. 11/14 P/N 9999970261 Bulletin 135 Rev.G TMIMI-- 0 Types: F1 Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/F1 Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/F1 Fl Res 76 Recessed Pendent/FP Fl Res 30 COP Pendent Fl Res 49 COP Pendent Fl Res 58 COP Pendent Fl Res 76 COP Pendent Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSW Recessed HSW/F2 Fl Res 44SWO Fl Res 40 HSW Fl Res 40 Recessed HSW/F2 Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E Slope Ceiling Approvals: Refer to Bulletin 035 Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers Product Description Model Fi Res Pendent sprinklers (Figs.i,2, 3, &4)are Model Fl Residential Sprinklers for Design Density of .05 gpm/ft2 Fl Res 30,49,58 & 76 Fl Res 30,49,58 & 76 Recessed Pendent I Fl Recessed Pendent / FP Fl Res 30, 49, 58 & 76 Fl Res 44&58 CCP Pendent Recessed HSW/F2 Fl Res 44 SWC Fl Res 40 Recessed HSW/F2 The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½" NPT (R½) K-Factor: 3.0 (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (Actual) - Fl Res 76 Pendent Sprinkler 4.4 (Actual) - Fl Res 44 HSW Sprinkler 4.0 (Actual) - El Res 40 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 C CD 0) I CD 0 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm/ft2 I11 response Jl II lNIl combiningWUlll ft UUFdUlll1y, high sensitivity glass-bulb and low profile decorative Application design. The Fl Res Horizontal Sidewall sprinklers (Figs. Model El Res Sprinklers are used for Residential Fire 5, 6 & 7) are equally attractive when above ceiling piping Protection according to UL 1626 Standard*. Be sure cannot be used. that orifice size, temperature rating, deflector style and The 3mm glass-bulb pendent sprinklers permit the sprinkler type are in accordance with the latest efficient use of residential water supplies for sprinkler published standards of The National Fire Protection coverage in residential fire protection design. Association or the approving authority having jurisdiction. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & Model Fl Res 30, 49, 58 & 76 Pendent SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 and 40 HSW with a ceiling to deflector distance of 4"- 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Model Fl Res 30 Recessed Pendent /172 Model Fl Res 49, 58 & 76 Recessed Pendent / Fl 1 escutcheon, 3/;' (19mm) adjustmei 135F003 Fig. 1 Fig. 2 Escutcheon*, Fl or F2, Data: Type Adjustment "A" Face of fitting to ceiling Inch (mm) Inch (mm) Inch (mm) Fl 3/4(19.0) Min.-Y," (19.1) Max.=1.4" (38.1) 3/615/6(47240) F2 Y, (12.7) Min.= 15/" (23.8) Max.=l/" (38.1) 3/ 1y (4.7-17.4) 16 16 * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent 2. Technical Data: Fl Res 30 Pendent and Recessed Pendent Nominal Spnnkler Max. Max Actual Sprinkler Thread Orifice Temp. Pressure Ambient K Length Size Inch Rating psi Temp. Factor Inch °F °C OF 0 (mm) (bar) (mm) 2"NPT 2/' (82) 155 1751 68 79 175(12) 100 38 3.0 2.25(57) Deflector - to - ceiling Maximum 1" (25mm) to 4" (100mm) Max. Sprinkler Spacing Flow Pressure I Sprinkler Identification ft (m) gpm(Lpm) psi (bar) I Number (SIN) 12 x 12 (3.6x3.6) 8 (30.3) 7.0 (0.48) R3511 14 x 14 (4.3x4.3) 10 (37.8) 11(0.76) Technical Data: Fl Res 49 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Actual Sprinkler Thread Orifice Temp. pressure Ambient K Length Size Inch Rating psi Temp. Factor Inch °F °c °F I 0 (mm) (bar) (mm) "NFT (11) 155 1751 68 79 175(12) 100 1501 38 66 4...0 2.25(57) Deflector - to - ceiling Maximum 1" (25mm) to 4!'(1 00mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 13(49) 7.0(0.48) R3516 16.7(1.14) 14 x 14 (4.3x4.3) 13 (49) 7.0(0.48) 16 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17(64.3) 12.0(0.83) 20 x 20 (6.1x6.1) 20(75.7) *Deftor - to - ceiling Maximum 4" (100mm) to 8" (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler I dentification Number (SIN) 12 x 12 (3.6x3.6) 15(57) 9.4 (0.65) R3516 1 20.2(1.4) 14 x 14 (4.3x4.3) 16(60.5) 10.6 (0.73) 16x 16(4.9x4.9) 17(64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19(72) 15.0(1.0) 20 x 20 (6.1x6.1) 1 22(83.2) *Nt The Fl Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: Maximum beam depth = 7" (178mm) Beam spacing ator greater than 7.5 ft. (2.3m) on center. Technical Data: Fl Res 58 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Thread Orifice Temp. Pressure Ambient K Length Size Inch Rating psi Temp. Factor Inch °F I oc OF oc (mm) (bar) (mm) ½" NPT (3) 155 68 175(12) 100 1501 38 66 5.8 2.25 (57) Max. Sprinkler Flow Pressure Ceiling -to- Sprinkler Spacing gpm (Lpm) psi ( bar) Deflector Identification ft (m) Inch (mm) Number (SIN) 12 x 12 (3.6x3.6) 16(61) 7.6(0.53) 1-4 (25-100) R3513 14x14(4.3x4.3) 16(61) 7.6(0.53) 16 x 16 (4.9x4.9) 16(61) 7.6(0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 14.4(1.0) 20 x 20 (6.1x6.1) 22(83.3) 3. Technical Data: Fl Res 76 Pendent and Recessed Pendent Nominal St3ñlkler Max Ma'ic I Sprinkler Thread Orifice Ten. Ressure Antient K Length Size Inch I Riing psi Inch Tenp. 00 OF 00 (mm) (bar) (mm) 3/47' NPT (R3/4) 1%3' (13.5) 155 175 68 79 175(12) 100 150 38 66 7.6 _ 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 21 7.6(0.53) R7618 I 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16x 16(4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 x 20 (6.1x6.1) 23 9.2(0.6 ) Model Fl Res 30, 49, 58 & 76 (X..F iencient Model Fl Res 30, 49, 58 & 76 Recessed Pendent / FP FP push-on/thread-off escutcheon 2 5/8 [66.7mm] DIA. 2 5/16" DIA. - HOLE IN CEILING [58.7mm] CUP I "x 1/2" REDUCER cup 1' CEILING I-- MAX. FACE OF R/NG j TO FACE OF CEILING F------ I DIMENSION H.. COVER ADJUSTMENT / F- 3 5/16" 135F004D [84.1mm] El RES 30, 49, 58 & 76 CCP PEND. CEILING 2 5/8' 08.. [65.7,'"J - HOLE IN CEILING 2 5/18 074. (58,7m,n] Cup L-_-_-----=--1 r I T2 IX I/2'l?EDUCER I 112"[3& '-m] MAX. FACE OF FIT1ING 10 FACE OF CEILING DIMENSION 7/2' (1-3 --1 MAX, FP ADJUSIMENt Fig. 3 Fig. 4 NOTE: The Fl Res 76 will use a 1" x 3/4" reducer. 11 CCP Options Data: "B" Cover Adjustment CCP Height Inch (mm) Inch (mm) 34(12.7) 15/6 (24) 5/(7.9) //4(19) FP Data "A": FP Position Inch (mm) Max. Recessed 3/6 (11) Mm. Recessed 15/6 (24) Technical Data: Fl Res 30 CCP Pendent and Recessed Pendent I FP Nominal Sprinkler Ca' As Mac Sprhkler Thread Orifice Temp. Temp, PeSW Ambient K Length Size Inch Rating Teni Factor Inch (mm) (rmi) °F °F 00 E I ..00 1/I2 NFl 23/64(82) 155i 68 1351 I 57 175 (12) iool I 38 3.0 25 (R½) 1 I 1 Max. Sprinkler Flow Pressure Sprinkler Spacing gpm(Lpm) I psi (bar) Identification ft (m) i I Number (-SIN)— 12 x 12 (3.6x3.6) I 8(30-3) 7.0 (0,48) R3511 13.4(0.92) 14 x 14 (4.3x4.3) 11(41.6) Technical Data: Fl Res 49 CCP Pendent and Recessed Pendent I FP Nominal SprinklerSprinkler CCP Max Max Sprinkler' Thread Orifice Tenii TetTiti Pressure, Antient K Length Size Inch Rating FfrIçJ psi Temp. Ftacor Inch (m) °F 00 ½" NPT 3/6 (11) 155i 68 1351 57 175(12) iool 38 4.9 2.25 (R½) I I Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12x12(3.6x3,6) 13_(49) 7.0(0.48) R3516 14 x 14 (4.3x4.3)— 13_(49) 7.0(0.48) 16x_16(4.9x4.9) 14(53) 8.2_(0.56) 18x_18(5.5x5.5) 18_(68.1) 1 13.5_(0.93) Nominal Sprinklerr Piess CCP Max Max Thread Orifice Tenç Terrill Ambient K Length Size Inch Rating psi Ten!1 Factor hch (mm) (bar) (MM) °F 00 ______ °F °FI 1/2"NPT 34 (13) 15568 _ _00 135 57 175(12) 5.8 2.25(57) Max. Sprinkler Spacing ft (m) Row gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) ___ 12x12(3.6x3.6) 16(61) 7,6(0.53) R3513 1 14.4(1.0) 14x_14_(4.3x4.3) 16(61) 7,6(0.53) 16 x_16(4.9x4.9) 16 61) 7.6(0.53) 18_x18(5.5x5.5) 19 (72) 1 10.8_(0.75) 20x20(6.1x6.1) 22(83.3) 20 x 20 (6. 1 x6. 1) 20 (75.7) 16.7(1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP Technical Data: Fl Res 76 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifice Inch (mm) Sprinkler Ten,. Rating Assen" CCP _Rallim Max Pressure psi (bar) Max. Antient Teni K FCtO Length ) °F I 0 °F op 34"NPT (R3/4) 13/3 (13.5) 15568 1751_79 _O( 13557 I 175(12) 100 150138 _ 66 7.6 2.25(57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) _ Sprinkler Identification Number (SIN) ____ 12x12(3.6x3.6) 21 7.6_(0.53) R7618 1 10.8(0.74) 14x_14_(4.3x4.3) 21 7.6(0.53) 16 x 16 4.9x4.9 1 21 7.6(0.53) 18x18(5.5x5.5) 1 22 1 8.4(0.58) 20 x 20 (6.1x6. 1) 1 25 5, Escutcheon, F2, Data: Type Adjustment I Face of Fitting I I to wall Inch (mm) I Inch (mm) I F2 (13) 3/1y5 (47174)I Model Fl Res 44 & 58 HSW Model Fl Res 44 & 58 Recessed HSW/F2 F2 escutcheon, /2" (13mm adjustment Technical Data: Fl Res 44 HSW & HSW/F2 Nominal Sprinkler LUL Max. Sptiiicler nad Orifice Tenii Premure Antient K Length Ste Inch Ftiig psi Inch Ten Faor OF I cc p (mm) (bar) (mm) 1/2"NPT (1O) 155 1751 68 175(12) 1OO 1501 38 66 0738 6 44 2.45(62) Ma.Spnnkler Spacing ft (m) dW Ceiling Deflector Inch (mm) Sprinkler Temp. Rating OF (°C) Flow gpm (Lpm) Pressure psi (bar) Spnnkler Identification Number (SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) __________ 155 (68) 175 (79) 12(45.4) 7.5 (0.52) R3531 14 x 14 (4.3x4.3) 155 (68) 175(79) 14(53.0) 10.2(0.71) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 16(60.6) 13.3 (0.92) 16 x 18 (4.9x5.5) 155(68) 175(79) 18(68.1) 16.8(1.16) 18x 18(5.5x5.5) 155(68) 175(79) 19 (72.0) 18.7(l.29) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23(87.1) 27.4(l.89) 12 x 12 (3.6x3.6) 6-12 (152-305) 155 (68) 175(79) 14(53.0) 10.2 (0.71) 27.4(1.89) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 16(60.6) 13.3(0.92) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 17(64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155 (68) 175(79) 20(75.7) 20.7(1.43) 16 x 20 (4.9x6.1) 155 (68) 175(79) 23(87.1) Escutcheon. F2. Data: Adjustment Face of Fitting I Type Inch (mm) to wall I Inch (mm) F2 /2 (13) Technical Data: Fl Res 58 HSW & HSW/F2 Nominal Spñilder Max Max Spri'Jder Thread Orifice Taip Pressure Ambient K Length Size Inch Fi psi Ten. FactDr Inch c I cc p I cc (mm) (bar) (mm) 1/2"NPT 155 175 68 I 79 175(12) 100 150 38 66 5.8 2.45 (62) Ma.Sprinkler Spacing ft (m) Ceiling Deflector Inch (mm) Sprinkler Temp. Rating °F (°c) Flow gpm (Lpm) Pressure p si (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 155 (68) 175 (79) 16(60.6) 7.6 (0.53) R3533 14 x 14 (4.3x4.3) 155 (68) 175 (79) 18(68.2) 9.7 (0.67) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 21(79.5) 13.2(0.91) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 25(94.7) 18.6(1.28) 16 x 20 (4.9x6. 1) 155(68) 175(79) 29(109.8) 25(1.73) 12x 12(3.6x3.6) 6-12 (152-305) 155(68) 175(79) 22(83.3) 14.4(l.0) 28.6(1.97) 14x 14(4.3x4.3) 155(68) 175(79) 22(83.3) 14.4(l.0) 16x 16(4.9x4.9) 155(68) 175(79) 26(98.4) 20.1 (1.39) 16x 18(4.9x5.5) 155(68) 175(79) 31(117.4) 7. Model Fl Res 44 SWC 4 to 72 (707.60mm To _________ I I/4 [37.75mm] Moe/mum 304.80mm] Face 0! Fitting PUSH ON COVER. THEN To Woll Dimension I TI/RN TO ADJUST UNTIL J TIGHT AGAINST WALL. I X I/2 Reducer —v Recommended I We Hole 2 TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER 27/32 WRENCH BOSS. 1Adsment Fl RES 44 SWC Fig. 5 Technical Data: Fl Res 44 SWC 11iaci Nominal Orifice Sprinkler Tenill CTØT1 Ratlig Wlax Pressure MK AntientTen. K Spriilder Length Size Inch Ratlig _________ psi ___________ Faor 1-ich OF ° OF °c ç (mm) (bar) (mm) 1/20 NPT (R1/2) W OO) __ 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) Max. Sprinkler Spacing ft (m) Ceiling -- Deflector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprin kler Identification Number (SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 13 (49.2) 8.7 (0.60) R3531 20.7(1.43) 14 x 14 (4.3x4.3) 14(53.0) 10.2 (0.71) 16 x 16(4.9x4.9) 17(64.3) 15.0(1.1) 16x 18(4.9x5.5) 19 (71.8) 18.7(l.13) 16 x 20 (4.9x6.1) 23(87.1) 27.4(1.89) 12 x 12 (3.6x3.6) 6-12 (152-305) 14(52.9) 10.2(0.71) 14x 14(4.3x4.3) 15(56.7) 11.7(0.81) 16 x 16 (4.9x4.9) 18(68.1) 16.8(l.16) 16x 18(4.9x5.5) 20(75.6) [:1 Escutcheon. F2. Data: Type Adjustment Face of Fitting I to wall Inch (mm) Inch (mm) F2 /2(13) 3/6 1/6 (47174)] 2 Model Fl Res 40 Recessed HSW/F2 F2 escutcheon, /" (13mm) adjustment 135FC05 FACE OF FITTING To - WALL DIMENSION I I/4 MIN. [31.8mm] I 2 I/4 HOLE ON. [5 7.2mm] [32mm] CEILING TO DEFLECTOR I" x l/2 REDUCER DIMENSION 1 15116- D14 2 27 /32 0/k [72.2mml TIGHT AGAINST SPRINKLER WRENCH BOSS. H 1/2W [73mm] ADJUSTMENT Fl RES. 58, 44 & 40 HSW/F2 Fig. 7 Technical Data: Fl Res 40 HSW & HSWIF2 Nominal Sprinkler MaxMax Sprinider 11iead Orifice Toy Ambient K Length Size Inch Riig psi Tenx Factor hch °F °c c cc ____ (mm) (bar) (mm) 1/2"NPT (R 112) WOO)175 155 175 68 79 (12) 100 150 38 66 4.0 2.45 (62) Max. Sprinkler Ceiling -- Sprinkler Temp. Flow Pressure Spnnkler Spacing Deflector Rating gpm psi (bar) Identification ft(m) OF (°C) Inch (mm) (Lpm) Number (SIN) 12x 12(3.6x3.6) 4 -6 (101-152) 155(68) 175(79) 13(49.0) 10.6(0.73) R3538 25,0(1.72) 14x14(4.3x4.3) 155(68) 175(79) 16(60.5) 16.0(1.10) 16x 16(4.9x4.9) 155 (68) 17(64.3) 18.1 (1.24) 16 x 16 (4.9x4.9)— 175 79 18(68.1) 20.2(1.39) 16x 18(4.9x5.5) 155(68) 175 79 20(75.7) 25.0(1.72) 18 x 18 (5.5x5.5) 155 (68) 175 (79) 22(83.3) 30.2 (2.08) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23(87.0) 33.1 (2.28) 12 x 12 (3.6x3.6) 6-12 (152-305) 155 (68) 175 (79) 13(49.0) 10.6 (0.73) 14x 14(4.3x4.3) 155 (68) 175(79) 17(64.3) 18.1 (1.24) 16x 16(4.9x4.9) 155(68) 175(79) 20(75.7) Am Finishes" Standard Finishes Sprinkler Fl, F2, FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White Polyester White Painted Coated I Special Application Finishes Sprinkler Fl, F2, Escutcheons Cover Plates Bright Brass Bright Brass Bright Brass Black Plated Black Plated Black Plated Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome I Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76, Fl Res 44 and El Res 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NEPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (681C)] [175°F (791C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30,49 & 58 Recessed Pendent/F2, Model Fl Res 30,49 & 58 Recessed PendentlFP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-F)] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard finish shall be [brass] [bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 3.0, 49 & 58 Recessed Pendent/El] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30, 49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). 10. Model Fl Res 30,49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (681C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (570C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl RES 40 and Fl Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model Fl Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.0 (57.1). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 40, SIN R3538 (Bulletin 135). Model Fl Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 40 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 40/F2, SIN R3538 (Bulletin 135). Model Fl Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (791C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model El Res 44, SIN R3531 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model El Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). 11. Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (791C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/172, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineerd to provide a minimum design density of 0.05 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 3/4" adjustment (Model El)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/F1] [Model Fl Res 76 Recessed Pendent/172] [Model Fl Res 76 Recessed PendentJFP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (570C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. I (800) 431-1588 Sales Offices 1 Recycled Rel~iab I (800) 848-6051 Sales Fax \/ Paper (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. w.reliablesprinkIor.com Internet Address EG. Printed in U.S.A. 06/08 P/N 9999970235 11 V_A'rz./_nc P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - STEEL - COPPER HANGER SIZE - 3/4" thru 3" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - ®an 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Hanger in listed mounting positions - Top, Bottom or Side. Also, provides stability on vertical piping. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions on top, bottom or side of building element. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre-drill. 3/4" - 3" Copper pipe - #905 screw - no pre-drill. 3/4" - 3" Steel pipe - 114"xl1/2" lag screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 3" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 3" Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. *CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other .4FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON svill NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. .4FCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or ealtacqucittial damages of any kind, including but not limited to loss of business or profit, when non-A FCON products have been, or are used. 2/08 Side View - For Drawings Below iz. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 SIDE MOUNT CPVC - COPPER HANGER SIZE - 3/4' thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - ®m 203 - EX 4231, EX 2551 FUNCTION - Hanger on CPVC and Copper pipe. INSTALLATION - Per NFPA 13,13R, 13D and CPVC manufacturers instructions on top or bottom of beam. Space by pipe type SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Hanger - Wood Stud Hanger - Metal Stud Specific .4FCON products are exclusively designed to be compatible ONLY with other 4FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - .4FCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business (Sr profit, when non-A FCON prodstcts have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC - STEEL - COPPER HANGER SIZE - 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Tab up = Hanger. INSTALLATION - Per NFPA 13,13R and 13D on side or top of beam. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. 3/4" - 2" Steel pipe - 1/4"x1 1/2" lag screw - no pre-drill. FEATURES * Offset edge eliminates abrasion. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Specific .4FCON products are exclusively designed to be compatible ONLY with other .4 FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-.4FCONprodttcts have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 OFFSET CPVC HANGER SIZE - 3/4" thru 3"pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized.. LISTING/APPROVAL - 203 - EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - 3/4"-2" Hanger/restrainer for horizontal CPVC, Copper or Steel pipe. Listed hanger/restrainer in all 3 mounting positions, i.e. vertical surface and both top and bottom of horizontal surface. Provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Size 2 Hanger for horizontal CPVC pipe. Listed hanger in all 3 mounting positions. i.e. vertical surface and both top and bottom of horizontal surface. Size 3" Hanger for horizontal CPVC pipe in two mounting positions, side and bottom. i.e. vertical surface and bottom of horizontal surface. Stabilizes vertical piping by providing horizontal restraint. INSTALLATION - Per NFPA 13,13R and 13D. Space by pipe type. Install on wood, concrete or steel - See Drawings. Snap over pipe then squeeze strap back allowing pipe to slide freely. Listed When #905 threads are exposed in wood, install #906 backing nut. 3/4' SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre-drill. 3/4" - 2" Copper pipe - #905 screw- no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre-drill. Thru 5/8" gypsum board - 1/4" x 2" lag screw. STEEL - mm. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener = 5(wt)+2501bs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and 1" pipe size made with common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. #906 Listed Restraint 3/4' thru 2" Specific .4FCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or said by AFCON. AFCON shall NOT be liable tinder any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. Pipe Manufactured for Viking SupplyNet by Viking Plastics, LLC (Huntsville, Alabama USA.) 4009vif. V Size Part 3/4" Number 34PIPE Bag Qty. 240 ft 1PIPE 150 ft 1-1/4" 114PIPE 105 ft 1-1/2" 112P1PE 751t 2P1PE 60 ft 2-1/2" 212PIPE 30 ft 3PIPE 15 ft BlazeMaster® CPVC fittings are manufactured/supplied for Viking SupplyNet by NIBCO, Inc. Standard Fittings Size 3/4" Part NumberBox V5011-007 Qty. 250 1" V5011-010 100 1-1/4" V5011-012 25 1-1/2" V5011-015 25 Tee Size I Part Number I Box Qty. Tee (continued) V5011-020 2 2-1/2" V5011-025 1 V5011-030 1 Size 3/4"x3/4"xl" Part NumberBox V5011R-102 Qty. 10 1"0/4"0/4" V5011 R-125 100 1"x3/4"xl" V5011 R-126 10 1"xl"x3/4" V5011 R-131 100 1-114"xl"04' V5011 R-157 5 1-1/4"xl"xl" V5011 R-158 25 1-1/4"xl"x1-1/4" V5011 R-159 5 1-1/4"xl-1/4"0/4" V5011 R-167 25 1-1/4"xl-1/4"xl" V5011 R-168 25 1-1/4"xl-1/4"xl-1/2" V5011 R-169 5 1-1/2"xl-1/4"0/4" V5011 R-201 5 1-1/2"xl-1/4"xl" V5011 R-202 5 1-1/2"xl-1/2"x3/4" V5011 R-210 25 1-1/2"xl-1/2"xl' V5011 R-211 25 Size I •t NumberBox Qty. Reducing Tees (continued) 1-1/2"xl-1/2"xl-1/4" V5011 R-212 5 1-1/2"xl-1/2"x2" V5011 R-213 5 2"x2"x3/4" V5011 R-248 2 2"x2"xl" V5011 R-249 10 2"x2"xl-1/4" V5011R-250 2 2"x2"xl-1/2" V5011 R-251 2 2-1/2"x2-1/2"x l" V5011 R-289 1 2-1/2"x2-1/2"x1-1/4" V5011R-290 1 2-1/2"x2-1/2"xl-1/2" V5011 R-291 1 2-1/2"x2-1/2"x2" V5011 R-292 1 3"x3"xl-1/2" V5011 R-337 1 3"x3"x2" V5011 R-338 1 3"x3"x2-1/2" V5011 R-339 1 Reducing Tee -( 3 www.vikinggroupinc.com Refer to manufacturer's DESIGN AND INSTALLATION GUIDE for technical specifications and installation instructions. Size 3/4" Part NumberBox V5007-007 Qty. 250 V5007-010 100 1-1/4" V5007-012 25 1-1/2" V5007-015 25 V5007-020 10 900 Elbow Cross Standard Fittings continued from Page 1 450 Elbow Coupling Size Part Number 3/4" V5035-007 m.ii 10 1" V5035-010 100 1-1/4" V5035-012 5 1-1/2" V5035-015 6 2" V5035-020 4 3/4" Size Part I V5001-007 Box I.11I 250 1" V5001-010 100 1-1/4" V5001-012 25 1-1/2" V5001-015 25 Size I Part Number I Box Qty. Cross (continued) 2-1/2" V5035-025 4 3" V5035-030 1 1"xl"x3/4"x3/4" V503511-131 10 Size I Part Number I Box Qty. Coupling (continued) V5001-020 10 2-1/2" V5001-025 1 V5001-030 Reducing Coupling Bushing Size •;iaiNumber lx 3/4" V5018-131 Box Qty. 100 1-1/4" x 3/4" V5018-167 25 1-1/4" x 1" V5018-168 25 1-1/2" x 3/4" V5018-210 5 1-1/2" x 1" V5018-211 25 1-1/2" x 1-1/4" V5018-212 25 2" x 3/4" V5018-248 2 2" x 1" V5018-249 2 Size I Part Number —1 Box Qty. Bushing (continued) 2" x 1-1/4" V5018-250 2 2" x 1-1/2" V5018-251 2 2-1/2" x 1-1/4" V5018-290 1 2-1/2" x 1-1/2" V5018-291 1 2-1/2" x 2" V5018-292 1 3" x 2" V5018-338 1 V5018-339 1 Cap www.vikinggroupinc.com Sprinkler Head Adapters BRASTIC° Sprinkler Size Part Number Box QtY. Head Adapter 3/4" x 1/2" V5003SBT-101 1 100 1" x 1/2" V5003SBT-130 50 * Brass starter thread molded into plastic, virtually eliminating cross-threading. Female Sprinkler Head Siz, Part Number Box Qty. Adapter with Metal Thread Insert 3/4" x 1/2" V5003SB1-101 100 C*j 1" x 1/2" V50035B1-130 50 1" x 3/4" V50035B1-131 10 Spigot Female Sprinkler ,,• Part Number Box QtY. Head Adapter with Metal Thread Insert 3/4" X 1/2" V500325B1-101 1 100 1" x 1/2" V50032SBI-130r 50 Metal Thread Insert Sprinkler Head 90 with Size 3/4" x 1/2" Part Number V50073SB1-101 I Box QtY. 100 1" x 1/2" V500735B1-130 50 1" x 3/4" V500735B1-131 10 1-1/4" x 1/2" V50073S81-166 5 Sprinkler Head Tee with Metal Thread Insert (7) Size Part lxix)" Number V5012SB1-010 IBox Qty. 50 3/4"x3/4"xl/2" V50125B1-101 10 1"xl"xl/2" V50125B1-130 50 1-1/4"xl-1/4"xi/2" V50125B1-166 5 1-1/2"xl-1/2"xl/2" V5012SBI-209 5 2"x2"x1/2" V5012SBl-247 2 Size Part Number I Box Qty. Sprinkler Head Tee w/Metal Thread Inserts (continued) 1"x3/4"xl/2" V5012RSBl-124 10 1-1/4"xl"xi/2" V5012R5B1-156 5 1-1/2"xl-1/4"xl/2" V5012RSBl-199 5 2"xl-1/2"xi/2" V5012RSB1-237 2 1 x1/2 x1* V5014RSBl122* 10 *Socket x FIPT x Socket Sprinkler Head Back to Size Part Number Box Qty. Back Cross with Metal Thread Insert ix1"x1/2"x1/2" 1-1/8" V503535815-130 1 IxI xi/2 xl/2 1-15/16" V503535B1L 130 1 Back to Back Tee with Size Part Number Metal Threads Insert 1/2"xl/2"xl" 1-1/8" V5011335B1S-075 48 (5 1/2 xl/2 xl 1-15/16" V501133SB1L075 48 Test Plug 1/2" V450-005 1 50 Size Part Number Box Qty. ~J www.vikiriggroupinc.com Size I Part Number I Box Qty. Standard Union (continued) V5033E-020 1 2-1/2" V5033E-025 1 V5033E-030 1 Standard Union Transition Fittings Female Adapter with Size Part Box Qty. I Size Part Number I Box Qty. Metal Thread Insert 3/4" V5003B1-007 10 Female Adapter w/Metal Thread Inserts (continued) 1" V5003Bl-010 50 1-1/2" V5003131-015 5 1-1/4' V5003B1-012 5 2" V5003131-020 2 Spigot Female Adapter '' Part Number I!Wj with Metal Thread Insert 3/4" V50032B1-007 10 1" V50032Bl-010 10 Male Adapter with ire Part Number Box Qty. Size Part Number Box Qty. Metal Thread Insert 3/4" V5004B1-007 10 Male Adapter w/Metal Thread Inserts (continued) 1" V5004Bl-010 10 1-1/2" V5004B1-015 5 1-1/4" V5004B1-012 5 2" V500481-020 2 C ~J,11' Grooved Coupling Size Part Number Box Qty. 'Ire Part Number Box Qty. Adapter 1-1/4" V5001 G-012 30 Grooved Coupling Adapter (continued) 1-1/2" V5001 G-015 25 2-1/2" V5001G-025 10 [ 2" V5001 G-020 15 3" V5001 G-030 8 Accessories Solvent Cement Size I Part Number I Box Qty Quart V5097Q M12 Pint V5097P Dauber Size Box Qty Small V5093-S 100 Large V5093-L 100 Size Part Number Box Qty 771 Size Part Number Box Qty Refer to manufacturer's DESIGN AND INSTALLATION GUIDE for technical specifications and installation instructions. c®us <e> @ APPROVED www.vikinggroupinc.com September 2010 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Quarry Creek SR#: (Assigned upon plan submittal) PROJECT ADDRESS: CITY: Carlsbad PHONE: (951 ) 667-4220 (NP Mechanical, Inc.) FAX NUMBER: (951) 667-4216 Largest Building (ft. 2 Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): (See attached. TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 94 PSI Hydrant Number (if applicable):New Elevation of test: 114 Feet Date/Time of Test': Pitot Tube Reading: Corresponding Flow: GPM Total Flow: 3,750 GPM Residual Pressure 66 PSI At peak demand, this water system is capable of providing a fire flow discharge @ 20 psi of greater than 8,000 GPM. However the velocity exceeds the maximum criteria of 10 fps. Therefore, the maximum available fire flow for this location is 3,750 GPM. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name:Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature: /1/z.O Title/Org:ect Manager Date: 7/7/2017 Confidential Page 1 7/11/2017 NP Mechanical Inc. 9225 SteUCoiit Stm A Camrka, C& 92883 July 11, 2017 D. Grubb Dennis Grubb and Associates, LLC 6550 Van Buren Blvd, Ste E Riverside, CA 92503 Hello, In regards to the correction sheet you provided for Cypress at the preserve the following corrections have been made: Provided new water flow. Hydraulic calculations have been revised accordingly. (See FP2) If you have any questions feel free to call me at any time. Juan Aguirre Fire Sprinkler Engineer NP Mechanical Inc. 951-667-4220 Ext. 351 9225 Stellar Ste. A Court Corona, CA. 92883 0 T (951) 667-4220 0 F (951) 667-4216 0 www.np-mechanical.com Dennis Grubb and Associates, LLC Assisting Cities Build Safe Communities PLAN CORRECTIONS (FIRE) DGA#: C7217 Carlsbad Permit#: FPR20I7-0255 Checked by: D. Grubb Jurisdiction: Carlsbad Applicant: NP Mechanical Phone#: 951-454-2107 Date of Review:6/30/1 7 Project Name: Cypress at the Preserve Project Address: 3242 Candelas St The plans submitted for the project referenced above have been reviewed. The following information is needed to show compliance with the 2016 California Building and Fire Codes (CBC and CFC), and other codes as adopted and amended by state regulation and the City of Carlsbad. It will be necessary to reevaluate the project after the receipt of additional information as specified below. INSTRUCTIONS Resubmit three sets of the revised plans along with one set of the original plans. Provide a written response for each correction on this correction list. You may write directly on this list, or you may provide a separate "Response List" which addresses each correction item by item. Incorporate all corrections into the blue/black line drawings; cloud or call out all corrections. Return plans to Dennis Grubb & Associates, 6550 Van Buren Blvd, Ste E, Riverside, CA. 92503 CORRECTIONS ON THE PLANS THE FOLLOWING SHALL BE PROVIDED: The water flow test report is over 12 months old. Provide a water flow report within the last 12 months. Revise hydraulic calculations accordingly. 6550 Van Buren Blvd, Ste E, Riverside, CA. 92503 (800) 975-7395 * (951)772-0007