Loading...
HomeMy WebLinkAbout5760 FLEET ST; 220; FS160006; PermitJob Address: 5760 FLEET ST Permit Type: FIXSYS Parcel No: 2111000200 Lot #: 0 Status: ISSUED Applied 3/1/2016 Approved: 3/1/2016 Uity OT uarlsbad Fixed Systems Permit Permit No: FS160006 Reference No.: Issued: 3/1/2016 PC #: Inspector: Project Title: STERKLY INERGEN SUPPRESSION STE. 220: NEW AUTOMATIC & MANUAL FIRE ALARM SYSTEM Applicant: Owner: SIMPLEX GRINNELL OT9 OWNER LLC ATTN:PAUL LEBEAU 3568 RUFFIN ROAD SOUTH 450 B ST #400 SAN DIEGO CA SAN DIEGO CA 858-583-0426 Fees ($) r Addtl Fees ($) Total ($) Balance ($) 460 0 460 I 0 Warranty - The components of the fire suppression system supplied by Ansul Inc. (ANSUL") are warranted to you as the original purchaser for one year from the date of delivery against defects in workmanship and material. ANSUL will replace or repair any ANSUL supplied components, which, in its opinion, are defective and have not been tampered with or subjected to misuse, abuse, or exposed to highly corrosive conditions provided that written notice of the alleged defect shall have been given to ANSUL within 30 days after discovery thereof and prior to the expira- tion of one year after delivery, and further provided that if ANSUL so instructs, such article or part thereof is promptly returned to ANSUL with shipping charges prepaid. Disclaimer of Warranty and Limitation of Damage - The warranty described above is the only one given by ANSUL concerning this system. ANSUL MAKES NO OTHER WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE. ANSUL'S MAXIMUM RESPONSIBILITY FOR ANY CLAIMS WHETHER IN CONTRACT, TORT, NEGLIGENCE, BREACH OF WARRANTY, OR STRICT LIABILITY SHALL BE LIMITED TO THE PURCHASE PRICE OF THE SYSTEM. UNDER NO CIRCUM- STANCES SHALL ANSUL BE RESPONSIBLE FOR SPECIAL, CONSE- QUENTIAL, OR INCIDENTAL DAMAGES OF ANY KIND. ANSUL does not assume or authorize any other person to assume for it any additional liability in connection with the sale of this system. For repairs, parts, and service of the ANSUL fire suppression system, contact a local ANSUL representative, or Ansul Incorporated, Marinette, WI 54143-2542,800-TO-ANSUL (862-6785). Subject to the conditions set forth below, ANSUL will, as purchaser's sole remedy, replace INERGEN gas and pay reasonable costs to recharge the INERGEN/Detection and Control System where, in ANSUL's opinion, the discharge has occurred due to a defect in the material or workmanship of the products provided by ANSUL. This warranty is extended only to the original purchaser of the INERGEN/Detection and Control System and only for a period of one year from the date of installation of the INERGEN/Detection and Control System. ANSUL will only replace INERGEN gas and pay reasonable costs to recharge the INERGEN/Detection and Control System where the discharge occurs due to a defect in the material or workmanship of the products provided by ANSUL. For example, ANSUL will not be responsi- ble for discharges due to faulty maintenance or installation or service, intentional acts by the owner or third parties, or circumstances over which ANSUL has no control. ANSUL will not be responsible for discharges of the INERGEN/Detection and Control System which occur if the INERGEN/Detection and Control System, as initially installed, has been altered or modified. This warranty shall be effective only if the original purchaser maintains a semi-annual service agreement for the INERGEN/Detection and Control System with an Authorized ANSUL Distributor from the date of installa- tion. This warranty covers only those INERGEN/Detection and Control Systems purchased from ANSUL or its Authorized Distributors and only those INERGEN/Detection and Control Systems which incorporate and use only hardware and components, including detection and control devices manufactured, sold, or approved by ANSUL This warranty may not be assigned or transferred to others. ANSUL Product Services Department must be notified within three days of the discharge of the INERGEN/Detection and Control System and must approve the cost of INERGEN gas and recharge service in advance. Except as provided above. ANSUL MAKES NO WARRANTIES OF ANY KIND, WHETHER EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, UNDER NO CIRCUMSTANCE SHALL ANSUL HAVE ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAl. SPECIAL OR SIMILAR DAMAGES. ANSUL SHALL HAVE NO LI ITY FOR ANY DAMAGES DUE TO DELAY IN RECHARGING TF "INERGEN"/DETECTION AND CONTROL SYSTEM. ANSUL'S MAXIMUM LIABILITY FOR DIRECT DAMAGES IS LIMITED TO REPLACEMENT OF INERGEN GAS AND REASONABLE COST RECHARGE THE "INERGEN"/DETECTION AND CONTROL SY This warranty is not effective unless Ansul Form No. F-9346 is completed and returned to ANSUL within 10 days of the commiss of the INERGEN/Detection and Control System. to 0 Maintenance is a vital step in the performance of a fire suppressio system. As such, it must be performed by an authorized ANSUL d tor in accordance with NFPA 2001 and the manufacturer's design, lation, recharge, and maintenance manual. When replacing comp( on the Ansul system, use only Ansul approved parts. For information on the proper design and installation, contact a I UM INERGEN System distributor. The ANSUL applications neenng department is also available to answer design and installat questions. Call 800-TO-ANSUL (862-6785). Pipe and Fittings - The system manifold must be constructed of Schedule 80 or 160 piping and 2000 or 3000 psi iron fittings, threaded or welded. The distribution piping down stream from the orifice union must be constructed of a minimum of Schedule 40 piping with class 300 malleable iron threaded fittings or welded steel fittings. All piping must be black iron of the following type and grade: ASTM A-53 seamless or electric resistance welded, grade A or B, or ASTM A-106 grade A, B, or C. Do not use ASTM A-i 20, ASTM A-53 type F or ordinary cast iron pipe or fittings. Limitations -The INERGEN system must be designed and installed within the guidelines of the manufacturer's design, installation, operation, inspection, recharge, and maintenance manual. The ambient temper- ature limitations are 32 IF to 130 IF (-0 °C to 54 °C). All AUTOPULSE Control Systems are designed for indoor applications and for tempera- ture ranges between 32 OF and 120 IF (0°C and 49 °C). LW Ira Applicable Standards: The INERGEN system complies with NFPA Standard 2001, Standard for Clean Agent Fire Extinguishing Systems, and EPA Program SNAP, Significant New Alternate Policy. Agent is listed and approved by Underwriters Laboratories, Inc. (UL) and Factory Mutual (FM). All system components and accessories must be installed by personnel trained by the manufacturer. All installations must be performed accord- ing to the guidelines stated in the manufacturer's design, installation, operation, inspection, recharge, and maintenance manual. -I Availability - INERGEN Systems are sold and serviced through a network of independent distributors located in most states and many foreign countries. Cost - Cost varies with type of system specified, size, and design. ANSUL, AuTopuLsE and INERGEN are trademarks of Ansul Incorporated or its affiliates. I I ANSULI tqc'13 / F/re & Tyco Safety Products 715-735-7411 Copyright 0200E Ansul Incorporated i Secu#/ry Marinette, WI 54143-2542 www.ansul.com Form No. F-9312-10 INERGEN® extinguishing agent used in ANSUL® engineered systems is particularly useful for hazards where an electrical, non-conductive medium is essential or desirable; where clean-up of other agents pres- ents a problem; where hazard obstructions require the use of a gaseous agent; or where the hazard is normally occupied and requires a non- toxic agent. The following are typical hazards protected by INERGEN systems: Computer rooms a Subfloors a Tape storage a Telecommunications/Switchgear a Vaults a Process equipment a All normally occupied or unoccupied areas where electronic equip- ment is either very sensitive or irreplaceable INERGEN is an effective fire extinguishing agent that can be used on many types of fires. INERGEN extinguishing system units are designed for total flooding protection against Class A surface burning, Class B flammable liquid, and Class C fires occurring within an enclosure by lowering the oxygen content below the level that supports combustion. INERGEN agent has been tested by FM Approvals for inerting capabili- ties. Those tests have shown that INERGEN agent, at design concentra- tions between 40% and 50%, has successfully inerted mixtures of propane/air, and methane/air. Specific gravity: 0.085 lbs./cu. ft. (1.36 kg/ms) Vapor density: 1.1 (Air= 1) Approximate molecular weight: 34 INERGEN agent is a mixture of three naturally occurring gases: nitro- gen, argon and carbon dioxide. As INERGEN agent is derived from gases present in the earth's atmosphere, it exhibits no ozone depleting potential, does not contribute to global warming, nor does it contribute unique chemical species with extended atmospheric lifetimes. Because INERGEN agent is composed of atmospheric gases, it does not pose the problems of toxicity associated with the chemically derived Halon alternative agents. INERGEN agent complies with the NFPA Standard 2001, Standard for Clean Agent Fire Extinguishing Systems and EPA Program SNAP, Significant New Alternate Policy. Agent is listed and approved by Underwriters Laboratories, Inc. (UL) and o. FM Approvals. Containers meet the applicable Department of Transportation (DOT) specifications. INERGEN agent is a plentiful, non-corrosive gas that does not support combustion nor react with most substances. INERGEN agent contains only naturally-occurring gases which have no impact on the ozone or the environment in general. INERGEN agent is a mixture of three inerting (oxygen diluting) gases: 52% nitrogen, 40% argon, and 8% carbon dioxide. INERGEN agent extinguishes fire by lowering the oxygen content below the level that supports combustion. When INERGEN agent is discharged into a room, it introduces the proper mixture of gases that still allow a person to breathe in a reduced oxygen atmos- phere. It actually enhances the body's ability to assimilate oxygen. The normal atmosphere in a room contains approximately 21% oxygen and less than 1% carbon dioxide. If the oxygen content is reduced below 15%, most ordinary combustibles will not bum. INERGEN agent will reduce the oxygen content to approximately 12.5% while increasing the carbon dioxide content to about 3%. The increase in the carbon dioxide content increases a person's respiration rate and the body's ability to absorb oxygen. Simply stated, the human body is stimulated by the carbon dioxide to breathe more deeply and rapidly to compensate for the lower oxygen content of the atmosphere. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. 10,1ANSULI ttJCD / Fire & Tyco Safety Products 715-735-7411 copyright ©2006 Ansul Incorporated Security Marinette, WI 54143-2542 www.ansul.com Form No. F-200045-2 ANSUL System Components UL EX-4510 3-1-06 Pagel-1.1 REV. 4 helWm. CV-98 Valve/Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN® agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft. (6.1 m) of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300 Valve Brass Safety Relief Valve Brass Valve/Cylinder Assembly FM Approved UL Listed (EX-451 0) Shipping Cap Steel Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426620 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426594 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435* (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) * NOTE: For Shanghai version, order Part No. 430935. Canadian TC Approved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427551 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426715 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies- Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427552 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426719 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD VALVE TAG HEIGHT TO OUTLET CENTER A 002251 3 1/2 IN. PRESSURE (89 mm) GAUGE REFERENCE SAFETY RELIEF EjJ.I1II__ VALVE -----k \ / \ / 002252 CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. NOTE: Use Flexible Discharge Bend, Part No. 427082, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETFE, Wi 54143-2542 715-735-7411 Form No. F-9877-4 02006 Ansul Incorporated ANSUL System Components UL EX-4510 11-1-00 Page 1-3.6 hekffl. Booster Actuator Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 1 1/4-18UNEF 11/8-18 UNEF 008037 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-2001066 ©2001 Ansul Incorporated Ifl*jms Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 73327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 OF to 130°F (-18°C to 54°C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage ..........12 VDC @ 0.57 amps Rated Voltage: Minimum: ...................12.0 VDC Maximum: ...................14.0 VDC Thread Sizelfype.........1/2 in. straight female for electrical conduit hookup Material: Body: ........................Brass Plunger: ..................Stainless Steel System Components UL EX-4510 11-1-00 Page 1-3.7 HF Electric Actuator Listings and Approvals UL .........................E91021 ULC..........................1165 FM . . . . . . . . . . . . . . . . . . . . . . . . 2T8A9.AF 2 1/4 IN. (57 mm) 00130$ ANSUL and INERGEN are trademarks of Ansul Incorporated or Its affiliates. TYCO SAFETY PRODUCTS, MAPINE1TE, Wi 54143-2542 715-735-7411 Form No. F-2001067 02001 Afoul Incorporated IflACjtern. Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. System Components UL EX-4510 3-1-06 Page 1-12 REV. 5 Flexible Discharge Bend Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer Component Material Thread_Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to mate 1/2 in. NPT Male FM Approved Discharge Bend Type AT mate with CV90 UL Listed (EX-451 0) and CV-98 Valve 18 7/8 IN. (47.9 Cm) p FEMALE ADAPTOR (BRASS) 1/2 IN. NPT WASHER MALE COUPLING CHECK VALVE END SWAGE MANIFOLD/END 000655 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. PCO SAFETY PRODUCTS. MARINETFE, WI 54143-2542 715-735-7411 Form No. F-9308-7 02006 Ansul Incorporated System Components UL EX-4510 3-1-06 Page 1-15 REV 7 hek". Pressure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. DIRECTI OF FLOV VISIBLE ORIFICE IDENTIFICATION 002197 Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer/ Body: Forged 1/2, 3/4, 1, FM Approved Union Steel 11/4, 11/2, UL Listed (EX-4510) 2 in. NPT Orifice Plate: Stainless Steel NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. Orifice diameter must be specified when placing Order. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MAF1INErrE, Wi 54143-2542 715-735-7411 Form No. F-9311-9 02006 Ansul Incorporated System Components UL EX-4510 11-1-00 Pagel-16.1 REV. 2 1800 Discharge Nozzle Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle 426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle Size A-in. B-In. C-In. 1/4 in. 5/8 19/16 21/32 3/8 in. 3/4 15/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 11/8 25/32 7/8 1 in. 113/32 29/16 1 11/4 in. 1 3/4 23/4 11/16 11/2 in. 2 231/32 11/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3m. 31/2 41/8 11/4 Oil 'iuj p [IRLjtOrnS " Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 180° nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8,1/2, 3/4,1, 1 1/4, 11/2,2, 2 1/2,3 NPT NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. _L _,~ 22 4 A 002743 * Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, \M 54143-2542 715-735-7411 Form No. F-99020-1 (22001 Ansul Incorporated rAl 1 hol. Ik ".I_ I Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing com- ponents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coat- ing. Uprights and back frame assemblies can be bolted or System Components UL EX-4510 3-1-06 Page 1-17 REV. 8 Cylinder Bracketing welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel FM Approved UL Listed (EX-4510) Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft.3 (9.9 m3). 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft.3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft.3 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut(for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row Multi-Cylinder Single Cylinder UPRIGHT D. WEIGH RAIL SUPPORT / BACK FRAME f \l V Ii I CYLINDER CLAMP I II II I Ij I I I CARRIAGE BOLT I j WITH NUT C Ij I II I / CLAMP RIGHT 1 1 BRACKET FOOT I II II CHANNEL I Ij II It II I LEFT BRACKET FOOT 002200 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, Wi 54143-2542 715-735-7411 Form No. F-9309-8 ©2006 Ansul Incorporated 7.00 System Components UL EX-4510 3-1-06 Page 1-23 REV. 1 Warning Plate - Inside Room With Alarm [Re .,k"® Description The warning plate is available for mounting inside the haz- ard area to warn the personnel to vacate the hazard area when the alarm sounds. The warning plate is furnished with four mounting holes for ease of installation. The plate is constructed of aluminum. Shipping Assembly Part No. Description 416265 Warning Plate - inside room with alarm Component Material Mounting Hole Size Approvals Warning Plate Aluminum 1/4 in. (.64 cm) FM Approved UL Listed (EX-451 0) 12.00 002746 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETIE, Wi 54143-2542 715-735-7411 Form No. F-9315-3 02006 Ansul Incorporated F1 1 11nAejeern System Components UL EX-4510 3-1-06 Page 1-24 REV. 2 Warning Plate - Outside Room Without Alarm Description The warning plate is available for mounting outside the hazard area to warn the personnel that the space is pro- tected by an INERGEN@ system and no one should enter after a discharge without being properly protected. The warning plate is furnished with four mounting holes for ease of installation. Shipping Assembly Part No. Description 416266 Warning Plate - outside room Component Material Mounting Hole Size Approvals Warning Plate Aluminum 7/32 in. (.56 cm) FM Approved UL Listed (EX-451 0) 8.00 WARNING THIS SPACE IS PROTECTED BY AN INERGEN® FIRE SUPPRESSION SYSTEM. WHEN SYSTEM IS DISCHARGED AS A RESULT OF FIRE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT APPROVED SELF- CONTAINED BREATHING APPARATUS OR UNTIL VENTILATION HAS BEEN OPERATED FOR AT LEAST 15 MINUTES. Ln% ffA-i LABEL NO. 416266 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. TYCO SAFETY PRODUCTS, MARINETTE, IM 54143-2542 715-735-7411 Form No. F-9314-4 02006AnsuI Incorporated 7.00 002747 £Simplex Release Control Fire Alarm Systems UL, ULC, CSFM Listed, FM Approved; 4004R Suppression Releasing Panel for Automatic MEA (NYC) Acceptance* Extinguishing, Deluge and Preaction Sprinkler Control IiUit4U Fire alarm control panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs) Two notification appliance circuits (NACs) Two releasing appliance circuits (RACs) Two special purpose monitor inputs (SPMs) that accept manual release request and manual abort request for Agent Release systems, and waterfiow and supervisory for Preaction or Deluge systems Three auxiliary relays with selectable functions Easily selected activity timing options Suppression release operation includes: Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection Combined agent release and preaction operation** JDCs are selectable for cross-zoning or for activation from a single detection input Short circuit RAC supervision Compatible with Listed/Approved 24 VDC or 2, 12 VDC series connected actuators Audible Escalation of Events: Single Audible Appliance Tone: Stage 1 activates Temporal or 20 bpm March Time pattern; Stage 2 activates 120 bpm March Time pattern to indicate release timer active; Release activates On Steady to indicate release timer expired and actuator is activated Dual Audible Appliance Control** (Single Hazard): RAC 2 provides a third NAC for dedicated Stage 1 Bell control; NACs 1 & 2 indicate release as On Steady Operator interface provides: Status LEDs per circuit for Alarm, Trouble, and Supervisory (where appropriate) Acknowledge, Alarm Silence, and System Reset Operating mode selection and timer selections when in programming mode Related system components: Coil supervision module 2081-9046, one per RAC Maintenance Switch, one per RAC Abort Switch Listed to UL Standard 864 and ULC Standard S527 irnrrrri Dedicated for Suppression Release. 4004R Suppression Release Panels provide conventional fire alarm control circuits and are equipped with the features required for a wide variety of single or dual hazard suppression release applications. Capabilities include automatic extinguishing agent release and deluge and preaction sprinkler control. ** Requires Software Revision 4.01 or higher. ----------------------------- Agent discharge path Actuator Agent Actuator circuit source I/IrI~J Coil supervisory module Maintenance Switch [jj] SPMI RAC1 RAC2 I I'AC 1 lD NAC2Cs 2,3, and f 4004R Suppression Release Panel 4004R Suppression Release Panel One-Line System Reference Drawing irnwwiirriaj Flexible I/O Capabilities. Four IDCs allow for either four separately monitored zones or two, cross-zoned connections. Two SPMs allow dedicated manual inputs for release or abort; for waterfiow and supervisory, or release/abort and pressure, depending on system type. Two releasing appliance circuits (RACs) supervise to the actuator coils and .activate the actuators when required. The two NACs and the three panel auxiliary relays provide status condition information. Easy Program Selections. The operator panel has a program mode that allows selection of panel operation type and detailed operating selections using an easily selected sequential programming operation. History Log. The last 50 events are stored in non-volatile memory. This information is accessed by connecting a technician's computer to the service port which is also used to set the date and time. I1T1IW1Ti 'i*iE1IT1 Operator Panel. The operator panel has alarm and trouble status indicating LEDs for each input and output, visible through the locking cabinet door (refer to diagram on page 4). Unlocking the door provides access to the Acknowledge, Alarm Silence, and System Reset pushbutton switches. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:314 for allowable values and/or conditions concerning material presented in this document. Ills subject to re-examination, revision, and possible cancellation. Additional listings may be applicable; contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster S4004-0002-3 9/2008 (Refer to specifications on page 6 for more information.) Four Class B IDCs provide coverage for either two cross-zoned areas or four separately zoned areas. IDCs are capable of supporting up to 30 Simplex current-limited smoke detectors or electronic heat detectors (see list on page 2) as well as manual stations and other compatible contact closure initiating devices. IDCs are capable of Class A operation with an optional adapter module and can be programmed as Style C (short or open initiates a trouble) for use with current limited devices only. Single hazard agent release applications monitor pressure switches with IDC 3 and tamper switches with IDC 4. Two Class B Special Purpose Monitoring Circuits (SPMs) are dedicated for manual release or abort, waterfiow and supervisory, or release/abort and pressure, depending on system type. Inputs are normally open switches. An abort switch stops release while activated and upon deactivation, the release operation occurs after a selectable time delay. Manual release inputs override abort switches and activate the release after selectable delays of from 0 to 30 seconds in 5 second increments For Dual Hazard applications, current limited abort operation is required. SPMs are programmable as Style C and capable of Class A operation with the optional adapter module. Two Class B NACs are provided for reverse polarity, notification appliance operation, each rated 2 A. Class A operation is available with the optional adapter module. NAC operation is selectable per application. Synchronized strobe operation requires a separate 4905 Series Strobe Synchronization Module (see product selection below), and a continuous, steady-on (non-coded) input from the NAC. Two Class B Releasing Appliance Circuits (RACs). Rated 2 A each, these circuits are dedicated to operating release control actuators. RAC cutout timing is selectable as no cutout, 45 seconds, or 1, 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes. For bell/horn/strobe single hazard applications, RAC 2 functions as a third NAC (NAC 3). Auxiliary Power Output. Two sets of output terminals are provided, one for continuous operation and the other for resettable operation, rated for 750 mA combined. Resettable terminals are provided for 4-wire smoke detector power. Standard Panel Auxiliary Relay Outputs. Three relay outputs are available, selectable as normally open or normally closed, rated 2 A @ 30 VDC, 0.35 p.f. inductive: Aux Relay 1 (Trouble) is energized when Normal and is de-energized with a common Trouble condition. Aux Relays 2 and 3 respond differently depending on the system type and whether single or dual hazard. Typical functions are: For Single Hazard Operation, Aux Relay 2 is the common Alarm relay. Aux Relay 3 can be selected to indicate pre-discharge (release time delay started), common supervisory, waterilow, or pressure switch relay, depending on the system type. For Dual Hazard Operation, Aux Relay 2 is for Hazard Area 1 common Alarm; Aux Relay 3 is for Hazard Area 2 common Alarm. Power Supply and Battery Charger. During alarm, the power supply provides 3 A at 25.5 VDC, filtered and regulated. The temperature compensated battery charger provides 27.5 VDC for charging batteries suitable for up to 90 hour standby and 10 minutes of alarm. External battery chargers and cabinets can he used for more hitery hackiin. Product Selection - ... ---.-.- Release Control Panels Model Color I Listings I Description 4004-9301 Beige I UL, ULC, CSFM, & FM I Basic Releasing Panel; operates with AC input of: 120/220/230/240 VAC, UL, ULC, CSFM, FM & 50/60 Hz (auto-select); includes: four lDCs, two NACs, two SPMs, two RACs, 4004-9302 Red MEA (NYC) 3 auxiliary relays, and 3 A power supply with battery charger, cabinet and door Expansion Modules Model Description I Reference 4004-9860 Auxiliary Relay Module; four dual contact relays selectable as N.O. or N.C.; rated 7 A Two maximum Select I @ 120 VAC resistive, 5 A c 30 VDC, 0.35 p.f. inductive; unsupervised contacts I as 4004-9864 Two Circuit Class A Adapter Module for lDCs, SPMs, or NACs Four maximum required System Batteries (See data sheet S4081-0001 for external battery cabinets with chargers and for larger battery sizes) Model Description I Reference 2081-9272 6.2 Ah battery, 12 V I I 2081-9274 loAh battery, 12V Select one battery model per system standby I I requirements; two batteries are required 2081-9288 12.7Ah battery, 12V I Release Control Systems Accessories (refer to additional information listed on page 3) Model Description 2081-9046 Coil Supervision Module, one required per RAC; refer to pages 6 and 7 for detail 2081-9048 Abort Supervision Module; encapsulated 5600, 1/2W resistor; for Dual Hazard SPM; allows non-current limited Abort and Manual Release stations to be on same circuit; refer to pages 6 and 7 for detail 4081 Series End-of-Line Resistor Harnesses; refer to data sheet S4081-0003 2099 Series Manual Stations for Releasing Applications; refer to data sheet S2099-0010 4905-Series Strobe synchronization modules; 4905-9914 for Class B, 4905-9922 for Class A; see data sheet S4905-0003 for details S4004-0002-3 9/2008 Reference Information, Compatible Simplex Détectôrs and other System Components Model Type Data Sheet 4098-9601 Standard detector Photoelectric smoke detectors for 2-wire and 4-wire Reduced sensitivity detector S40980015 4098-9605 bases Combination smoke and heat detector 4098-9602 S4098-0017 4098 Series Ionization Smoke Detectors; 2-wire and 4-wire models S4098-0018 4098-9612 135° F (57°C) Fixed heat detector 4098-9614 200° F (93°C) Electronic heat detectors for 2-wire and 4-wire bases S4098-0014 4098-9613 135° F (57°C) Fixed with rate-of-rise heat detector 4098-9615 200° F (93°C) 2099-9149 Standard Manual Release Station with selectable release labels; double action push, N.O. contact S2099-0010 2099-9152 Style C, with 560 fl internal resistor 2080 -Series Maintenance Switches, flush or surface mount; indicator lamps require 24 VDC wiring S2081-0010 Abort Switches, surface or flush mount; available standard or with 1.2 k1), 1 W resistor I Ernansion Mnd!Ilts and Actssnris Auxiliary Relay Module 4004-9860 provides four additional relays. Dual hazard applications will require two modules for auxiliary relay operation. Each relay module has a manual disconnect switch that controls relays 2 through 4. (Trouble Relay 1 is not controlled.) Relay outputs are required to be connected to a 15 A maximum circuit breaker. (Relay specifications are detailed on page 6.) Auxiliary Relay Module Operation: Relay I activates on a common trouble associated with its hazard or a system trouble. Relay 2 activates on a common alarm associated with its hazard. Relay 3, selected for original operation, activates for pressure switch, waterfiow switch, or release timer as required per application type (hazard specific), or activates with the second zone for cross-zoned systems (hazard specific). "Original" operation allows direct panel replacement if required. Relay 3, selected for enhanced operation, (software 4.01 or higher), activates to indicate pre-discharge, supervisory, or waterflow (application specific). Relay 4 activates when the hazard specific RAC activates or with pressure switch input (application specific). Dual Circuit Class A Adapter Module 4004-9864. This module converts two Class B circuits to Class A operation. It consumes no additional current and is compatible with JDCs, SPMs, and NACs. Up to four modules may be mounted within the 4004R cabinet. Abort Switches. For manual abort requests, these abort switches are available with or without a built-in 1.2 k, 1 W resistor and are mounted on single-gang stainless steel plates. Abort switches are connected to the SPM inputs per system requirements. Activity abort occurs while the switch is pushed and continues after releasing the switch for the selected Abort Release Time Delay. (See drawing below.) Maintenance Switch. Proper service of release appliance circuits requires the ability to securely disconnect the release circuit during installation and maintenance. Simplex maintenance switches are controlled by keyswitch and initiate a supervisory condition when in disconnect/disable position. Models with lamp are on a double-gang plate and are powered from separate 24 VDC wiring. Mounting is on stainless steel plates and models are available as either surface or flush mount. (See drawing below.) For additional Maintenance and Abort Switch information refer to data sheet S2080-0010. FIRE SUPPRESSION SYSTEM ABORT PUSH AND HOLD Simplex Abort Switch NORMAL I CJ DISABLE Q FIRE SUPPRESSION DISCONNECT I DISABLE Maintenance Switch S4004-0002-3 9/2008 Progrämming Modes and Selection Choices Sequence Select one of 13 Application Modes (numbered I through 13 in italics) ('rn7Anasr1 I (',-,n,kint,1 Agent Release Single Hazard ____________________ - Either Zone 2 '_#'•JII kill lki I (RACs activate together) Dual Hazard Cross-Zoned 3 Independent Release (RACs are separate) Either Zone 4 Preaction/Deluge Single Hazard ____________________ Cross-Zoned 5 Combined Release (RACs activate together) Either Zone 6 Dual Hazard Cross-Zoned 7 Independent Release (RACs are separate) Either Zone 8 Agent Release; Single Hazard Cross-Zoned 9 NYC Abort (not UL listed) Agent Release & Preaction; Single Hazard Cross-Zoned 10 RAC 2 provides Preaction Control; RAC 1 is Agent Release Control Either Zone 11 - Agent Release, Bell/Horn/Strobe; Single Hazard Cross-Zoned 12 RAC 2 operates as NAC 3 for Stage 1 Bell Control (separate sound from release alarm) Either Zone 13 Sequence Programming Mode Description Description 2 Select Relay Operation for Select "Original" operation mode or "Enhanced" mode (refer to Auxiliary Relay 3 Application Modes 1-9 information on page 3 for details) 3 IDC and SPM Circuit Style Class B/Class A or Style C 4 Automatic Release Time Delay Selectable in 5 second increments from 0 to 60 seconds (default is 60 seconds) 5 RAC Cutout Timer No cutout, 45 seconds, or 1, 3, 3.5, 4, 5, 6, 7, 21, 25, 34, 44, or 64 minutes 6 Manual Release Time Delay 0, 5, 10, 15, 20, 25, or 30 seconds UL Standard 864 listed Immediate or 10 seconds remaining Abort Release Time Delay Not UL Standard 864 IRl abort (cross-zoned systems only), NYC abort, or listed original release delay 8 NAC Coding (where selectable) Temporal pattern or 20 beats per minute (first cross-zone alarm) Standard No inhibit or one minute inhibit selected as: both on until silence, NAC 1 on until Operation reset and NAC 2 on until silence, or both on until reset; NAC Operation Pre-Discharge NOTE: For Halon 1301, Halon 1211, or clean agent release, a pre-discharge NAC g Operation must be configured to warn of impending discharge, the release timer selects the duration of the pre-discharged signal 10 Supervisory Latching Latching or non-latching 11 Supervisory Notification LED and tone-alert only, or with: NAC 2 also on; Aux Relay 3 also on; or both NAC 2 and Aux Relay 3 also on Operator Panel Function Reference LABEL INSERT selectable for - U ALrm -- - - —' Preaction/Deluge, Agent Release, or RUN MODE: LEDs provide - Zone 1 I : Combination Agent Release/Preaction Alarm (red) and Trouble (yellow) 0 roubio Zone 5 Trot__J o Deluge, UL or ULC versions (UL Agent status per DC zone; Zone 4 Release version shown for reference) yellow LED indicates supervisory Q Alarm - Manual Rele o status if still flashing after ACK —Zone [, ZoneS Trot I J o RUN MODE: red LEDs indicate Manual _____________ Release activated (for Agent Release PROGRAM MODE: Top ten 0 Alarm NAC 1 Trot a Applications); yellow LEDs indicate LEDsindicate Pr H— Zone - i- Trouble for SPMs (Zones 5 and 6)and ograrnrning Q Troebl NAC 2TroubieJ C NACs for RACs, yellow LED indicates supervisory if still flashing after ACK Alarm Silenced yellow LED 0-------PROGRAM MODE: indicates that audible Top nine LEDs provide notification appliances are : 0 Siienced Agent Released Q LProgramming Selection silenced prior to system reset : 1Supervisory I Earth Fault 0 - Agent Released red LED Supervisory and System 0 (System Trouble ) Abort Active 0 indicates RACs are activated Trouble yellow LEDs; for UL systems, indication of disabled (AC P Relay Disconnect - - - - Earth Fault yellow LED indi c RAC Abort Active yellow LED tracks state of Abort Switch with normal power status indicates that expansion relays k have been disabled a tes or disconnected presence o an earth fault AC Power green LED is on V1 R&ayDisconnect yeOowLED ACK acknowledges status during RUN mode and accepts selection during PROGRAM mode; ALARM SILENCE SYSTEM RESET restores the system to normal during RUN press and hold for 5 sec to perform LAMP TEST silences audible alarms mode and to the selection during PROGRAM mode 4 S4004-0002-3 9/2008 Automatic Extinguishing Release Systems automatically activate actuators for the release of a fire extinguishing agent (thy chemical, water spray, foam, CO2, Clean Agent, etc.) in response to fire detection device input. Automatic Extinguishing Release Systems with Separate Bell Control (single hazard) (SW rev. 4.01 or higher). RAC 2 operates as a bell control NAC. When cross-zoned, stage 1 alarm activates the bell until the release timer starts. When not cross-zoned, stage 1 alarm activates the bell until expiration of the release timer. In both cross-zoned and non cross-zoned applications, NAC2 may be programmed to indicate either a tamper switch supervisory condition or the start of the release timer using a cadence pattern operation. UL and FM Extinguishing Release System Panels must have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Actuators must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil supervision. (See details in next section.) Deluge and Preaction Sprinkler Systems automatically activate water control valves in response to fire detection device input. Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control valve. They are used to deliver water simultaneously through all of the open sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. Preaction Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is maintained in the pipe. Operation requires both an activated sprinkler head and an activated fire alarm initiating device. Combined Agent Release and Preaction Systems provides agent release and preaction control. (Available with software revision 4.01 or higher.) For applications where agent release may not be sufficient for fire control, sprinklers are put in preaction mode to allow waterfiow to continue the fire response. (Preaction is assumed, selected deluge could be provided, determined by the sprinkler installation, panel operation is the same.) UL requirements for Fire Alarm Systems Listed for Automatic Release or Deluge and Preaction Sprinkler Systems are the same as described above for Automatic Extinguishing Release Systems. FM Approved requirements for Fire Alarm Systems for Automatic Release of Deluge and Preaction Sprinkler Systems require operation of specific compatible FM Approved Automatic Water Control Valves, a minimum secondary power capacity of 90 hours, and all circuits for the automatic release initiating devices must be capable of operation during a single open circuit fault condition (Class A). Actuators are connected as two-wire, Class B notification/releasing circuits with only one 24 VDC actuator per circuit to ensure supervision. Where applicable, two, 12 VDC actuators in series, or one 12 VDC actuator and a manufacturer supplied series resistor may be used. Coil Supervision Module, model 2081-9046, must be wired electrically before the actuator and located in the actuator wiring junction box. (See diagram on page 7.) For UL Listed Automatic Extinguishing Release valves and actuators, refer to list on page 7. For FM Approved Automatic Extinguishing Release, secondary standby must be a minimum of 24 hours with 5 minutes of alarm. Actuators must be electrically compatible. For FM Approved Deluge and Preaction Sprinkler operation: IDCs must be Class A. wired to Listed/Approved devices; secondary standby capacity must be a minimum of 90 hours with 10 minutes of alarm; and the specified compatible Automatic Water Control Valves/Actuator must be used. (See list on page 8.) Power supply loading and wiring distances must be per Installation Instructions 579-354. Battery standby must be selected for proper actuator operation and may require a minimum voltage of 23 VDC depending on the actuator. Detailed battery calculation reference information is contained in Installation Instructions 579-354. Maintenance Switches, one per RAC, are required per NFPA 72®, the National Fire Alarm Code®, to allow the system to be tested or serviced without actuating the fire suppression systems. Their use may not be allowed in some jurisdictions, always confirm local requirements. When used, Simplex Maintenance Switches are required to ensure that operation initiates a supervisory condition. Simplex Abort Switches are available when abort operation is required. When used, wire on Special Purpose Monitoring Circuits (SPMs) as Class A or Class B; Simplex model Abort Switches are required. Manual Release Stations are used -for direct activation of the release actuators with the appropriate time delay implemented by the fire alarm control panel. See pages 2 and 3 for additional reference information. This data sheet is a summary of the extensive operating features and options available with the 4004R Release Control Panel. Complete details are covered in the 4004R Installation, Programming, and Operating Instructions manual (publication 579-354) shipped with each 4004R. Compatible system devices are listed on page 3. For general information, refer to Factory Mutual Research Corporation (FMRC) "FMRC Approval Guide," FM Approval standard "Deluge Systems and Preaction Systems." PLEASE NOTE: Proper operation of release control systems requires that the system design, installation, and maintenance be performed correctly and in accordance with all applicable local and national codes, and equipment manufacturer's instructions. No liability for total system operation is assumed or implied S4004-0002-3 9/2008 Specifications (Refer to diagramon page 7 and Instructions 579-354 foi"additioñal information) Power Ratings AC Input Voltage Ratings Current Ratings 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select 2 A maximum @ 120 VAC input; 1 A maximum @ 240 VAC input Power Supply Output 3 A maximum available for external loads Battery Charger Temperature compensated, capable of recharging batteries required for 90 hour standby and 10 minute alarm (contingent on auxiliary power load) Standby Current 100 mA; with lDCs fully loaded, tone-alert silenced, trouble LED on, charger off Alarm Current 264 mA + external loads; (2 zones in alarm & 2 internal relays, NACs and RACs on) Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum; see NAC ratings for details) Supervisory 3 mA maximum; 3.3 kQ end-of-line resistor per circuit Initiating Device Alarm Current 75 mA maximum Circuits (IDCs) Output Voltage 28 VDC maximum Capacity Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required; wiring distance is limited to 50 0 maximum Application For Manual Release, Abort Switches, or Supervisory functions only; not for detectors; wiring distance is limited to 50 0 maximum Special Purpose For Dual Hazard Dual Hazard Application Abort Switches require a current limiting resistor of 1.2 kO, Monitoring Circuits Applications 1 W, or an external Abort Supervision Module per SPM (SPMs) Supervisory 6 mA; 3.3 k0 end-of-line resistor per circuit Activated 75 mA maximum Output Voltage 28 VDC maximum Special Application appliance rating = 2 A maximum on a NAC NOTE: Special Application appliance rating = full 3 A power supply rating Alarm Current Regulated 24 DC appliance power = 1.5 A maximum on a circuit Notification Appliance Circuits NOTE: Regulated 24 DC strobe load = 1.35 A maximum total for power supply (NACs) Output Voltage Alarm = 26 VDC max.; supervisory = 29 VDC maximum; 10 kO end-of-line resistor Synchronized Requires NAC dedicated to strobe control with non-coded output; use an external Strobe Operation Synch Module (4905-9914, Class A, or 4905-9922, Class B, see data sheet S4905-0003 for details); up to 33 strobes can be synchronized per 4004R Notification Special Application Simplex 4901 Series horns, 4904 and 4906 Series strobes, 4903 Series 4-wire Appliance Appliances horn/strobes; refer to Installation Instructions 579-354 for additional details Reference Regulated 24 DC Power for other appliances listed to UL Standard 1971 or UL Standard 464; use Appliances associated external synchronization modules where required Output Current 2 A maximum per circuit Release Appliance Circuits (RACs) Output Voltage Activated = 26 VDC maximum; non-alarm = 29 VDC maximum; 10 kO end-of-line resistor Auxiliary Power Output; for Special Two outputs are available, continuous operation or resettable operation; combined Application loads only output is 750 mA maximum; output voltage = 19.25 to 27 VDC Auxiliary Relay Outputs Contacts rated 2 A @ 30 VDC, 0.35 p.f., inductive, selectable as N.O. or N.C. by (Trouble, Aux Relay 2, Aux Relay 3) jumper Wring Connections for Above and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Auxiliary Module Ratings Class A Adapter Module 4004-9684 Two circuits per module, rated same as circuits; not applicable to RACs (no additional current required) Relay Type Four relays with two outputs per relay; individually selectable as N.O. or N.C. AC Ratings 7 A @ 120 VAC, resistive Auxiliary Relay Module 4004-9860 DC Ratings 5 A @ 30 VDC, 0.35 power factor, inductive Module Current 12 mA standby; 70 mA with all four relays energized; @ 24 VDC Wring Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) 2081-9046 Coil Supervision Module and 2081-9048 Abort Supervision Module (see page 7 for additional details) Construction Epoxy encapsulated Dimensions 1-3/8"W x 2-7/16" Lx 1-1/16" H (34 mm x 62 mm x 27 mm) Wring 18 AWG (0.82 mm2) wire leads, color coded Coil Supervision Module Current Rating 2 A maximum; internally fused at 3 A, non-replaceable Abort Supervision Module Resistance 560 0,1/2 W Environmental Ratings Operating Temperature Range 326 to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4° F (38" C) maximum 6 S4004-0002-3 9/2008 4004R System Connection Reference A Listed/approved actuator or Deluge and Preaction Automatic Water Control Valve; one if 24 VDC (or 2 in series if 12 VDC) per RAC Actuator wiring -_...J junction box Yel BIk + Out- - Abort Supervision Module 2081-9048 : Red Blk (for dual hazard mode with non-current limited devices on the SPM) Coil Supervision Module 2081-9046 Maintenance Disconnect Switch 11 o-o--------i -24 VDC for Maintenance Disconnect status indicator (if required) L7 A"required) ( Stations LIJE SPM1 SPM2 IDC1 Li Manual fire—" alarm station Compatible IDCs 2, 3, and 4 detection devices NAC1 LJ II Typical horn only_NAC FIRE Horn/Strobe NAC2 4004R Suppression Release Panel GENERAL WIRING NOTE: Wiring shown is for reference only, refer to installation instructions for detailed wiring information. Compatible UL Listed Valves and Actuators MFG. ANSUL Model Number *AUTOMAN Il-C Assembly (solenoid 17728; coil 25924) MFG. ASCO Model Number 821 0A107 (097617-005D coil) 1/2" NPS, 5/8" orifice, 24 VDC AUTOMAN II-C Explosion-Proof Releasing Device (solenoid 31492; coil 31438) 8210G207 (238310 coil) 1/2" NPS, 1/2" orifice *AUTOMAN Il-C Assembly (solenoid 68739; coil 25924) 8211A107 (097617-005D coil) 24VDC Solenoid Electric Actuator (solenoid 73111; coil 73097) HV2628571 (23810 coil) N.C. 1/2" NPS, 1/2" orifice *CV90 HF Electric Actuator 73327 (may use 73606 in-line resistor) HV2648581 (23810 coil) N.O. 1/2" NPS, 1/2" orifice R8210A107 (097617-005D coil) 1/2" NPS, 5/8" orifice LP CO2 w/ASCO solenoid 422934 T8210A107 (097617-005D coil) 1/2" NPS, 5/8" orifice LP CO2 double action 24 VDC solenoid 430948 p Chem ECH Electrical Control Head (551201) LP CO2 3-way selector valve solenoid 433419 Electric Actuator 24 VDC solenoid 570537 El Explosion-Proof Electric Actuator (570147) Removable Electric Actuator (570209) 0.2 A 713955N2ENJ1 111 11C2 (Skinner coil 1111C2) 1/4", NPS, 1/16" 73212BN41N00N0C111C2 (Skinner coil C111C2) 1/2", 5-300 psi Skinner 732128N4TNLVN0C322C2 (Skinner coil C322C2) 1/2", NPS, 0.92 A, 250 psi 73218BN4UNLVNOH1 11 C2 (Skinner coil Hill C2) 73218BN4UNLVNOC111 C2 (Skinner coil C1 11 C2) 1/2", NPS, 5/8 in. orifice Star Sprinkler Model D deluge valve, with solenoid 5550 12 VDC coils, either wire two in series for 24 VDC activation, or, if available from manufacturer, use series resistor 7 S4004-0002-3 9/2008 \ Manual Release Optional 4905-9914 or RAC 1 I 4905-9922 Strobe Synchronization Module Typical strobe only t"JAC FM Approved Water Control Valves Group A Manufacturer Skinner Model Number LV2LBX25 Details 24 VDC, 11 W, 458 mA, 1/2 inch NPS, 1/2 inch orifice B ASCO 182 10A107 24 VDC, 16.8W, 700 mA, 1/2 inch NPS, 5/8 inch orifice R8210A107 8210A107 C Star Sprinkler 5550 24 VDC, part of Model D deluge valve D ASCO 8210G207 24 VDC, 10.6W, 440 mA, 1/2 inch NPS, 1/2 inch orifice E Skinner 73218BNJ4UNLVNOC11IC2* 24 VDC, 10 W, 420 mA, 1/2 inch NPS, 5/8 inch orifice 73212BN4TN00N0C111C2 24 VDC, 10 W, 420 mA, 112 inch NPS, 5/8 inch orifice; 5-300 psi F Skinner 73212BN41NLVN0C322C2 24 VDC, 22W, 1/2 inch NPS, 920 mA, 250 psi (1725 kPa), 1/2 inch orifice G Skinner 71395SN2ENJ1N0H111C2 24 VDC, 10 W, 420 mA, 1/4 inch NPS, 1/16 inch orifice, 250 psi (1725 kPa) rated working pressure Vitaulic Series 753-E solenoid valve 24 VDC, 8.7 W, 1,2 inch NPS, 364 mA, 300 psi (2069 kPa), 1,2 inch orifice Viking11591 and 11592 Normally closed (NC) Explosion proof solenoid valves, 24 VDC, 10 W, Normally open (NO) 1,2 inch NPS, 300 psi (2069 kPa), 4.1 Cv 11595 and 11596 K Viking 11601 and 11602 NC solenoid valve, 24 VDC, 9W, 1,2 inch NPS, 250 psi (1725 kPa), 6.2 Cv *For new applications, LV2LBX25 has been replaced by model number 73218BN4UNLVNOC11IC2. Box width 14-5/8" (372 mm) (Top and side views are Typical conduit entry area shown with door installed) _,_. (cut holes as required) Box depth 4-1/4" (108 mm) I' 11-1/4(286mm) k N Class A adapter boards)J Li LI Aux. relay .siL2 ...sJ12 4E IlII['& module 1 I Oi O 13-1/2" I Aux. relay module 2 CMainboardD ot~i~ 0 (343 mm) 0j —4-00 L JAC_ input )III (Battery Area No conduit or wirinq in this area Door thickness 5/8" (16 mm) 16" (406 mm) 13-1/4" (337 mm) (Front view module placement reference showing NOTE: For semi-flush mounting, cabinet mounting hole dimensions, optional Class A must extend 1-1/2" (38 mm) adapter modules, and optional relay modules) minimum from wall surface NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. Tyco is a registered trademark of Tyco international Services GmbH and is used under license. Simplex, and the Simplex logo are trademarks of Tyco international Ltd. and its affiliates and are used under license. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). 5Siniplex Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S4004-0002-3 9/2008 www.tycosafetyproducts-usa-wm.com 0 2008 Tyco Safey Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Series MT and MT Strobe Multitone Electronic Appliances . L I L J d SERIES MT STROBE MT4-115-WH SERIES MT-12124 Description: The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panel incorporating the Wheelock Patented Sync Protocol. The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, 12VDC or24VDC. Strobe versions are specific for either 12VDC or24VDC and all models may be used with filtered or unfiltered (full-wave- rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADNNFPA/UFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable candela settings at 15/30175/110cd or with single candela 1575cd strobes. Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 (D ::,.- 14 <g> MEA APPROVED E5946 151-92-E 7135-0785:118 (MT4) 7125-0785:155 (MT) 7125-0758:156 (MTVVP) NOTE: All CAUTIONS and WARNINGS are identified by the symbol ,&. All warnings are printed in bold capital letters. Ak WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for 12VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-1 2/24, MTWP and MT4 models and listed for outdoor use at -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Current Ratings for Multitone Audible Portion RMS Current (amps) dBA@ l Oft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 120 VAC HI Output - STD Output HI Output - STD Output HI Out STD Output HI Output STD Output HI Output STD Output HI Output STD Output @ 24 VDC UL max* © 24 VDC UL max* © 24 VDC UL max* t 24 VDC - UL max* UL max* UL max* Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 85 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 82 75 March Time 0.067 0.104 0.033 0.038 0.109 0.142 0.023 Horn 0.034 0.050 0.040 89 84 89 74 85 79 Code-3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 82 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 85 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 10.041 89 84 89 75 85 82 HI/LO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 82 79 Table 2: Strobe Current Ratings RMS Current (amps) Model MT-121575 MT-241575 MTWP-2475 MT-24MCW Candela 1575cd 1575cd 180cd 15cd 30cd 75cd llOcd @ 24VDC 0.152 0.060 0.094 0.041 0.063 0.109 0.140 UL maxTr 0.255 0.090 0.138 0.060 0.092 1 0.165 0.220 Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (1 6-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams (for all models) MT SIGNAL FRO + +0 TO NEXTU - _RPLIOMCE ORE OPPLIDOECC, S SM/DODD COLDS PS-E2/240?, 0 P5-12/24-ROPES PM/DDE SUPPLIES orD + - SIGNALD LJDIBLE SIGNAL AND STROBE PERATE INDEPENDENTLY PRSCCDIEO/D LOOSES £505 PRECEDED PS 12124—P SM/CORED PS-U/OS-DISC + M CX EU STROBED AUDIBLED AUDIBLE SIGNAL AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROND I TO NEXTD PRECEDINGO RESM APPLIANCEd APPLIANCED OR FACPD —LIOR EOLRD I— STROBW 055IBLE0 I Specifications and Ordering Information Model Number Order Code Input Voltage Rated Candela Mounting Options*** Agency Approvals UL MEA CSFM FM BFP MT-12/24-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-12/24-W 5024 1 12/24 - D,E,F,L,M,O,P,R X X X X X MT241575WFR# 8422 24 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-24MCW-FR 3301 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * * MT-24MCW-FW 3303 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * MT121575WFR# 8421 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-121575W-NW 9747 12 15(75onAXIS) DE,F,L,M,O,P,R X X X X * MTWP2475WFR** 8420 24 180 @77°F (25°C) M X X X X * MTWP2475WNW* 9744 24 180 @77°F (25°C) M X X X X * MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-WH-VFR 6224 120 VAC 15 D,E,J,K,N,O,R X X X X X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R x * * * MT4-12/24-S 7997 12/24 - D,E,J,K,N,O,R X * * * * NOTE: °°MTWP-2475W is Weatherproof and rated for 180 cd @ 77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. * # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. Pending ## Series Wi-I Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-1 2/24, P84155 MT w/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). S2000 MT 10/07 Notification Cooper Notification is Wheelock' (MEDCJ SAFEPATH WAV Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30175/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-1 2/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuois development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. FEAM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA Li Simplex Releasing System Peripherals UL, ULC, CSFM Listed, FM Approved; Non-Coded Manual Stations MEA (NYC) Acceptance* for Releasing Applications Manual fire alarm stations for releasing applications: Double action push and pull operation with a normally open (N.O.) contact Current limited model is available with series connected 560 n resistor for Style C operation (current limited = alarm; open or short = trouble) Operation complies with ADA requirements Pull lever protrudes when alarmed Break-rod is supplied (use is optional) Label kit provides six varieties of releasing applications (ordered separately) Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as SimplexW fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes UL listed to Standard 38 nrtir Double Action Push Type Manual Release Stations require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station, reducing the possibility of an accidental activation. A firm downward pull of the lever then activates the alarm switch, breaking an internal plastic break-rod, visible below the pull lever. Break-rod use is optional. Use of a break-rod can provide an additional reduction of the possibility of an accidental activation without interfering with the minimum pull requirements needed for easy activation. When activated, the pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. H 1 PULL DOWN Double Action Push Type Manual Release Station (shown with sample release label) Label Kit 4099-9802 A blank area on the front of the station allows the selection of a label to match the specific release application (label kit is ordered separately). (Refer to data sheet S2099-0007 for standard Simplex manual stations.) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:175 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use —City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S2099-0010-2 8/2007 Product Sélectiôn Double Action, Push Operation, Manual Release Stations Model Description 2099-9149 Standard operation, N.O. contact Manual release station, red housing with white letters and white For Style C operation, N.O. contact pull lever; requires label kit 4099-9802 2099-9152 with series connected 5600 resistor - 4099-9802 I Label kit; select the label required for the specific release application; types include: Clean Agent, Extinguishing, Carbon Dioxide, Foam System, Sprinkler, and Manual Accessories Model Description Reference 2975-9178 Surface mount Steel 2975-9022 red box Cast aluminum Refer to page 3 for dimensions 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 for details 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit Black Refer to page 4 for details 2099-9820 Beige 2099-9804 Replacement break-rod Specifications Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire (0.82 mm to 2.08 mm 2) Temperature Range 32° to 140° F (0° to 60° C) intended for indoor operation Humidity Range Up to 90% RH at 90° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4" W 1" D (127 mm x 95 mm x 25 mm) Semi-Flush Mounting Reference Single Gang Box Mount Single gang box, 2-1/2° deep (64 mm), RACO #500 or equal (supplied by others) 4" Square Box Mount 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) Mount flush or with 7_1 1 " 1/16" (2 mm) maximum extension DO NOT RECESS T(1 (ThU LI p _ 4" Square box with cover plate Station FIRE JUI _ALARMJ side view PUSH ] Single gang cover plate, 3/4" PULL DOWN (ig mm) extension, RACO #773 or equal (supplied by others) L 1 ) RELEASE j ,, single gang box outline Wall surface Semi-Flush Mount Side View 2 S2099-0010-2 8/2007 SurfaceMountirig Referéncé Preferred Mounting. For surface mounting, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 5-3/16Hx4Wx2-3/16" D (132 mm x 102 mmx 56 mm) (ordered separately) \ Knockouts located top and bottom 2975-9022 Cast Box 5" H x 3-7/8 W x 2-3/16 D (127 mm x 98 mm x 56 mm) (ordered separately) Lel FRE] PUSH 0 PULL DOWN Access for 3/4" threaded 5• conduit located top and bottom (127 mm) RELEASELo sirioex MANUAL ] 1" (25.4 mm) 3-3/4 (95 mm) 2099 Series Manual Release Station Surface Mount Side View Simplex 2975-9178 box (shown for reference) Station cover hinges open for installation access 3 S2099-0010-2 8/2007 2099-9813 Semi-flush trim for 2-gang switch box, 6" H x 4-1/2" W (152 mm x 114 mm) For retrofit and new installations, additional compatible mounting boxes and the required Wiremold adapter plates are shown in the illustration to A= CM&receptacle box the right 2099-9814 Surface trim model V5744-2 for Wiremold box (supplied by 1/8" H x 5 W others) (130 mm x 127 mm) j,y C CD Two gang switch box, each U 3" Hx2"Wx2-3/4" 0 (J____ (76 mm x 51 mm x 70 mm) (supplied by others) I[ni1 III Re 1rn.]iiimrrn Flush mount adapter kit 2099-9819, Black 2099-9820, Beige t ..- ,-.. Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) 8" (203 mm) 6" (152 mm) Hole cutout must be a DULL DOWN minimum of 6" H by 5" W L (152 mm by 127 mm) _ T Wall 4-3/4" (121 mm) surface 6-3/4" (171 mm) :0 0 0 4-11/16" (119 mm) square box, 2-1/8' (54 mm) minimum depth (by others) Front View Side View Tyco, Simplex, and the Simplex logo are trademarks of Tyco Services AG or its affiliates in the U.S. and/or other countries. Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. SirnpIex Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S2099-0010-2 8/2007 www.tycosafetyproducts-usa-wm.com 02007 Tyco Safely Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. aSimplex Releasing System Peripherals UL, ULC, CSFM Listed; Fire Suppression System Abort Switches and Releasing MEA (NYC) Acceptance* Appliance Circuit (RAC) Maintenance Switches I1t!I(31 Abort switches provide a manual Fire Suppression System release abort request: Pushbutton momentary switch is mounted on a stainless steel single-gang plate A protruding collar protects the switch from accidental contact (collar is removable if required) Available flush or surface mount Flush mounting requires standard single-gang box Surface mounting includes a red mounting box Models are available with internal 1.2 kK2 resistor for current limited operation Maintenance switches provide a secure and visible disconnect means for servicing Fire Suppression System Releasing Appliance Circuits (RACs): Maintained position keyswitch is mounted on a stainless steel double-gang plate Key is removable in either normal or disabled position Disabled position opens connection to output circuit and places a 16.2 kQ resistor across the input circuit to initiate a supervisory condition at the host panel Disconnect indicator lamp is a bright incandescent bulb with red lens, powered from separate 24 VDC Available for flush or surface mount Flush mounting requires a standard double-gang box Surface mount models includes a red mounting box UL listed to Standard 864 scrintie Releasing systems typically require maintenance disconnect switches and often require abort switches. These abort and maintenance switches are clearly labeled and combine easy operation with rugged construction for high integrity operation. FIRE SUPPRESSION SYSTEM ABORT 011 PUSH AND HOLD Abort Switch (shown 1/2 size) (I. NORMAL DISCJ EIDISABLE \ FIRE SUPPRESSION DISCONNECT! DISABLE 35impIex ' Maintenance Switch with Disconnect Indicator Lamp (shown 1/2 size) * Refer to page 2 for specific product listings. NOTE: MEA is not applicable to Maintenance Switches. FM is not applicable to Abort Switches. As indicated on page 2, these products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:313 for allowable values and/or conditions concerning material presented in this document. Abort switches are accepted for use - City of New York Department of Buildings - MEA35-93E. Maintenance switches were not approved by FM as of document revision date. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S2080-0010-2 11/2006 Product Selectiôñ '(see page 3 fórspecificàtions) Abort Switches Model Description Listing Status 2080-9056 Flush mount UL, ULC, & CSFM 2080-9057 Surface mount; includes listed; MEA (NYC) red mounting box Acceptance Details Single-gang size; includes 3 position contact block housing with one contact block installed Abort Switches for 4004R Series Suppression Release Panel Current Limited Operation Model ' Description Listing Status I Details 2080-9067 Flush mount UL, ULC, & CSFM I Single-gang size; includes 1.2 kQ, 1W resistor for current Surface mount; includes listed; MEA (NYC) limited operation and 3 position contact block housing with 2080-9068 red mounting box Acceptance one contact block installed Maintenance Switches with Disconnect Indicator Lamp Model Description Listing Status Details 2080-9059 Flush mount Double-gang size; includes 3 position contact block housing UL, ULC, & CSFM with 2 contact blocks installed; disabled position opens 2080-9060 Surface mount; includes listed connection to output and places a 16.2 k) resistor across the red mounting box input circuit; resistor is removable if required for retrofit Accessories for Field Installation Model Description 2080-9061 Additional Contact Block for Abort or Maintenance Switch; 1 Form C contact; UL recognized component for use with these switches; listings and approvals are not applicable Abort Switch Installation Reference Red box is supplied with surface mount Abort Switch 2080-9057 or 2080-9068 Box width 3" (76 mm) aD FIRE SUPPRESSION SYSTEM ABORT 0 PUSH AND HOLD aD BSimpex L_ Abort Switch I width, 2-3/4" (70 mm) Supplied gasket attaches to box; field installed for flush mount; pre-attached for surface mount 2 2-1/4" (56 mm) into box -------------------- Box height t1 4 (70 mm) - NOTE: For flush mounting, use a 2-3/4' deep (70 mm) single-gang box S2080-0010-2 11/2006 1/2' Abort Switch (13mi height 4-1/2" (114 mm) - Switch recess depth 5/32" (4 mm) Removable collar Maintenance Switch InStàIIatioA RëféréAcé Red box is supplied with surface mount Maintenance Switch 2080-9060 Box dimensions 4-13/16 (122 mm) square 2-1/4 (56 mm) into box NORMAL DISCJ I DiSABLi . FIRE SUPPRESSION DISCONNECT I DISABLE 4-1/2" (114 mm) Maintenance Switch width 4-9/16' (116 mm) Supplied gasket attaches to box; field installed for flush mount; pre-attached for surface mount 2-3/4" (70 mm) NOTE: For flush mounting, use a 2-3/4" deep (70 mm) double-gang box rifittir Electrical Ratings Abort Switch; One Contact block Silver contacts; 1 N.O. & 1 N.C.; rated 2 A resistive @ 30 VDC Maintenance Switch with Lamp; Circuit control: Silver contacts; 1 N.O. & 1 N.C.; rated 2 A resistive @ 30 VDC Lamp control: Silver contacts; 1 Form C; rated 2 A resistive @ 30 VDC Two Contact blocks Maintenance Switch Indicator Light (models 2080-9059 and Replaceable 2 W incandescent bulb; 24 to 30 VDC typical; 83 mA @ 24 VDC; requires 2080-9060) separate 24 VDC Wiring Connections Abort Switch Terminal blocks for in/out wiring; 18 to 14 AWG wire (0.82 mm to 2.08 mm 2 ) Abort Switch with Current Limited Terminal blocks for first wire connection; 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2 ); Resistor 18 AWG wire lead for second wire connection Maintenance Switch 18 AWG (0.82 mm ) color coded wire leads for suppression circuit; terminal blocks for lamp wiring; 18 to 14 AWG wire (0.82 mm2 to 2.08 mm 2 ) Environmental Ratings Temperature Range 32° F to 120° F (0° C to 49° C) Humidity Range Up to 93% at 90°F (32° C) 3 S2080-0010-2 11/2006 Tyco, Simplex, and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries Simplex Tyco Safety Products Westminster • Westminster. MA • 01441-0001 • USA S2080-0010-2 11/2006 www.tycosafetyproducts-usa-wm.com 02006 Tyco Safety Products Westminster. All rights reserved All specifIcations and other information shown were current as ofdocument revision date and are subjecl to change without notice. B®Simplex TrueA!arm® Smoke Detectors UL, ULC, CSFM Listed; FM Approved; TrueAlarm Photoelectric Smoke Detectors MEA (NYC) Acceptance* for Two-Wire and Four-Wire Bases Photoelectric smoke detector with on-board TrueAlarm sensitivity drift compensation** Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: 4098-9601, Standard Sensitivity, nominal 2.80/o/ft obscuration* 4098-9605, Special Application Sensitivity, nominal 3.50/o/ft obscuration Available options: Bases for 2-wire or 4-wire operation Auxiliary alarm relay output Remote alarm indicating LED Designed for EMI compatibility UL listed to Standard 268 I'14-Ill1ll us] 1 Simplex® TrueAlarm photoelectric detectors provide many of the proven TrueAlarm analog sensing features for applications where detectors are connected to conventional 2-wire or 4-wire initiating device circuits (IDCs). Each TrueAlarm detector has an on-board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarrn detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high performance smoke capture ability* * Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. 4098-9601 TrueAlarm Photoelectric Detector Mounted in Base Specifications Voltage 15 to 32 VDC from Fire Alarm Control Panel IDC Standby Current 100 ILA @ 24 VDC Alarm Current, 2-Wire Up to 86 mA maximum, exact Operation current is determined by alarm current limiting of connected IDC Alarm Current, 4-Wire Operation 24 mA typical @ 24 VDC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 m/min) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. 15° to 122° F (-9° to + 50° C) Range Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non-condensing Color Frost White 4-7/8' Dia. x 1-7/8" H, mounted in Dimensions base (124 mm x48 mm); refer to page 3 for detail * ULC listed model is 4098-9601. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7272-0026:219 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573 S4098-0015-6 812009 b Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accumulation of dust and dirt. With TrueAlarm analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. (See page 3.) .nnlir.tir Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke detector spacing of 30 ft (9.1 m) may be used as a guide. For detailed installation information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). Sensitivity Selection. The 4098-9601 standard sensitivity detector is recommended for most applications. When a special application for a reduced sensitivity detector is required, the 4098-9605 should be considered. Consult your local Simplex product supplier for assistance in determining the proper selection. diitt Sktir Smoke Detectors Model Nominal Sensitivity Description I Compatibility 4098-9601 2.8%/ft (standard) 4098-9605 3.5%/ft (special application sensitivity, I Compatible with bases: 4098-9788, TrueAlarm Photoelectric Detector I 4098-9682, and 4098-9683 not ULC listed) I Compatible Bases Model Description Details* 4098-9788 2-Wire Base with connections for IDC and LED connections are screw terminals for in/out wiring, Remote Alarm LED Indicator 18 to 14 AWG 4-Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @ 28 VDC; Non-power limited, 3 A @ 120 VAC 4098-9682 Remote LED Alarm Indicator Wiring Connections (In/Out where required): NOTE: Requires external 24 VDC for operation Relay contacts and IDC wiring, color coded 18 AWG leads; LED wiring, screw terminals for 18 to 14 AWG 2-Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A @ 28 VDC; Non-power limited, 1/2 A @ 120 VAC Indicator ndicator NOTE: Must be connected as the only Wiring Connections (In/Out where required): device on the IDC to ensure relay Relay contacts and IDC (-), color coded 18 AWG leads; operation. IDC (+) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model Description Details* Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098-9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098-9788, -9682, & -9683 4098-9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098-9739 Encapsulated Dimensions: 2-1/2"x 1-1/2"x 1" Required for 4-wire circuits using 24 VDC (64 mm x 38 mm x 25.4 mm) I 4098-9682 base, one per circuit; select I End-of-Line Relay Mounted on single gang mounting type as required; wiring is color 2098-9735 Plate Mounted stainless steel plate coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm2; 14 AWG = 2.08 mm2 S4098-0015-6 8/2009 LED Indication Status Pulses approximately every 4 seconds Normal Steady On I Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal, sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, Alarm is initiated compensation range Cleaning or other then turns ON service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, _ __________________________ compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574-709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.41 mm) _k "(162 4098-9832 Adapter Plate 4-7/8" (124 mm) "I Base height 1 1(48 1-7/8" 11/16" mm) (17 mm) I_I_III_I_III_I Thl_H_F-1/TI7 "—_LED Status Indicator (with clear lens) 4098-9601 & -9605 Dimensions Mounted on Base ALARM 0 fiSlmpex 4098-9830 Remote LED Indicator (not to scale) 3 S4098-0015-6 8/2009 Mounting Information (Electrical boxes are supplied by others.) Electrical Box Requirements: Without !Qi (base 4098-9788): 4" octagonal or 4" square, 1-1/2' deep Single gang, 2" deep With relay (bases 4098-9682 and 4098-9683): 4" octagonal, 1-1/2" deep, with 1-1/2" extension ring 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference 4(102mm square box 4" (102 mm) octagonal box 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and to 4" square flush mount boxes 4098-9682 and 4098-9683 include a relay module that mounts in base electrical box Smoke Detector Bases 4098-9788, 9682, & -9683 4098-9601. -9605 Smoke Detector Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, TrueAlarm, and the Simplex logo are trademarks of Tyco International Ltd. and its-affiliates and are used under license. NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). £Sirnplex Tyco Safety Products Westminster• Westminster, MA 01441-0001 USA S4098-0015-6 8/2009 www.tycosafetyproducts-usa-wm.com 02009 Tyco Safe/y Products Westminster. All rig/its reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. Simplex Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger Il1II (4 Rechargeable, sealed lead-acid batteries: Lead-calcium grid structure with immobilized electrolyte in absorbent separator Low maintenance with no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover with high reliability dual seal construction UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ali up to 50 Ali, depending on control panel cabinet size Larger batteries, up to 110 Ali, mount in external battery cabinets that are available with internal chargers Includes battery chargers with communications compatibility for use with 4010 Series fire alarm control panels and with 4100U Series fire alarm control panels I1111 4.li1PtT1 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Where required, external battery cabinets can be close-nippled to the control panel to house larger batteries with battery chargers available in some battery cabinet sizes. I:1ijva.xei11r1 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) flTUII Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Remote Battery Cabinets are Available for Larger Battery Requirements Shipping. Sealed lead-acid batteries are shipped via ground or sea transportation only. They are not shipped via air. Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. * Refer to details on page 4 and to the referenced individual product data sheets for agency listing status of battery cabinets and chargers. The batteries detailed in this document meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S2081-0006-19 10/2008 Battery Côntructiôn Reference Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size) Potting material, black for negative, red for positive (polarity is also clearly 1) marked with + and -) Pressure relief valve Inner Absorbent separator used to immobilize electrolyte Semi-permeable Lead-calcium grids / membrane separator Cell group/ Cell case (high impact polystyrene) Battery Size Specifications Battery Model Capacity @ 20 Hour Width* Depth* Height with Approximate Discharge Rate Terminals Weight* 2081-9272 6.2 Ah 6-1/8' (156 mm) 2-5/8' (67 mm) 4" (1102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) (102 mm) 4"(102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4' (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) (127 mm) (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8' (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4' (197 mm) 5-1/4' (133 mm) 6-3/4' (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 5-1/2" (140 mm) 8-7/8" (225 mm) 41.8 lbs (19 kg) 2081-9279 110 Ah 11-3/16" (284 mm) 10-1/2" (267 mm) 9' (230 mm) 82 Lbs (37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output, these batteries are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. General Battery Specifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) 2 S2081-0006-19 10/2008 iBattery Compatibility fórFi(eAlárni Co'nfrôl Päiiél'Mbuntiñ'j NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series (see legend and notes below) Battery Capacity 4003 - - 4004 4004R 4005 4006 & 4009 4010 4100U 4100 & 4120 4020 Model 4008 (all models) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Ah / / I 1 1 1 1' 1, 2, or 3 bay 1 1 2081-9274 10 Ah 1 1 1 1 1 / / 1,2,or3 bay 1 .1 2081-9288 12.7 Ah I NA 1 1 1 1 1 1,2,or3bay / I 2081-9275 18 Ah I NA Note 3 1 Ext Ext Note 2 1, 2, 013 bay I I 2081-9287 25 Ah NA NA Note 3 Ext Ext NA 1 1, 2, or 3 bay I Ext 2081-9271 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay Ext Note 4 (rectangular) 2081-9276 33 Ah NA NA Note 3 Ext NA NA Note 3 1, 2, or 3 bay I Ext ("square") 2081-9296 50 Ah NA I NA Note 3 1 NA I NA NA Note 3 2 or 3 bay Ext Ext 2081-9279 110 Ah Requires external battery cabinet I = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 NA = Not applicable/not compatible NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. External Battery Cabinet Compatibility Reference Battery Cabinets without Chargers (connects to charger in panel) Cabinet Panel Compatibility 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 Rectangular 33 Ah 2081-9276 Square 33 Ah 2081-9296 50 Ah 2081-9279 110 Ah 2081-9270 multiple / I / / I NA 2081-9280 4100U/4100+ NA NA NA NA NA I 2081-9281 2081-9282 multiple I I I I I NA 4009-9801 multiple I 1" NA NA NA NA 4009-9802 multiple / NA / NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 1 1 / 1 / NA 4081-9302 4081-9306 4100U NA NA NA NA * Batteries smaller than those listed are normally mounted in the product cabinet ** 25 Ah capacity was effective as of 7/2005. I = Can be placed in the respective equipment cabinet NA = Not applicable/not compatible S2081-0006-19 10/2008 E*tèrnal Battery Cabinet SpeàificátioñRéfèrencé Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and FM 2-Unit, 4100 style cabinet without charger; with locking solid door and battery shelf, primarily for use with 50 Ah 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red batteries 40099801* Beige UL and For up to 25 Ah I External battery cabinet without charger, 16-1/4' W x 13-1/2" H x 5-3/4" D FM batteries* I with locking solid door and battery harness; for close-nippled mounting to (413 mm x 343 mm x 146 mm)* For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) * Depth increased for 25 Ah batteries effective 7/2005. Battery Cabinet Without Charger; Deep Design with Hinged Lid Model Color Listings Description Dimensions 2081-9270 Red Not listed Battery cabinet without charger; cabinet has vented front, 26-1/2" W 12" H x 12" D and hinged lid with support rod and lock on top (673 mm x 305 mm x 305 mm) Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model I Color I Input Voltage I Description I Dimensions 4081-9301 Beige I Battery cabinet with charger for the 4010 and 4004R fire alarm control panel; for up to 50 Ah 120 VAC batteries; with front door 22-1/2" Wx16-3/4" H x 8-3/8" D 4081-9302 Red Listings include: UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) (NYC), see data sheet for details I Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model & Listings Color Cabinet Description Compatible Chargers Charger Description 4100-9xxx 4100U System Power Supplies Series (SPS) 4100-5111 Battery cabinet for 4100-5112 41001.1 Additional SPS 2081-9279, 110 Ah 4100-5113 4100-5125 4100U Remote Power Supply 2081-9280 batteries; includes Listings Red 80 A battery fuse, 4100-5126 (RPS) include: UL terminals and 4100-5127 and CSFM battery connection 4100-5120 cables; see data 4100-5121 4100U TrueAlert Addressable sheet for details 4100-5122 Power Supply (TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 Dimensions 26-1/2"Wx 12" H x 12" D (673 mm x 305 mm x 305 mm) 4100U Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions 4081-9306 Red 120 VAC Battery cabinet with charger for up to 110 Ah batteries; NOTE: Required for ULC listed charging of 27-7/8" W 13-1/2" H x 14-5/8" D 4081-9308 Red 220/230/240 VAC, 110 Ah batteries; Listings include: UL, ULC, FM, (708 mm x 343 mm x 371 mm) multi-tapped CSFM, and MEA (NYC), see data sheet for details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing, mounts above access panel using knockout provided Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license. Tyco Safety Products Westminster• Westminster, MA •01441-0001 USA S2081-0006-19 10/2008 ,Simplex www.tycosafetyproducts-usa-wm.com 0 2006 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without no/ice. - INERGEN agent is a mixture of three naturally occurring gases: nitro- gen, argon, and carbon dioxide. As INERGEN agent is derived from gases present in the earth's atmosphere, it exhibits no ozone depleting potential, does not contribute to global warming, nor does it contribute unique chemical species with extended atmospheric lifetimes. Because INERGEN agent is composed of atmospheric gases, it does not pose the problems of toxicity associated with the chemically derived Halon alternative agents. The INERGEN Fire Suppression System, manufactured by ANSUL, is an engineered system utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When property designed, the INERGEN system will extinguish surface burning fire in Class A, B, and C hazards by lowering the oxygen content below the level that supports combustion. INERGEN agent has also been tested by FMRC for inerting capabilities. Those tests have shown that INERGEN agent, at design concentrations between 40% and 50%, has successfully inerted mixtures of propane/air, and methane/air. The system can be actuated by detection and control equipment for automatic system operation along with providing local and remote manual operation as needed. Accessories are used to provide alarms, ventilation control, door closures, or other auxiliary shutdown or functions. When INERGEN agent is discharged into a room, it introduces the proper mixture of gases that will allow a person to breathe in a reduced oxygen atmosphere. A system installation and maintenance manual is available containing information on system components and procedures concerning design, operation, inspection, maintenance, and recharge. The system is installed and serviced by authorized distributors that are trained by the manufacturer. Basic Use -The INERGEN system is particularly useful for suppressing fires in hazards where an electrically non-conductive medium is essen- tial or desirable; where clean-up of other agents present a problem; or where the hazard is normally occupied and requires a non-toxic agent. The following are typical hazards protected by INERGEN systems: D Computer rooms Subfloors Tape storage Telecommunication/Switchgear Vaults Process equipment All normally occupied or unoccupied electronic areas where equip- ment is either very sensitive or irreplaceable Composition and Materials - The basic system consists of extinguish- ing agent stored in high strength alloy steel cylinders. Various types of actuators, either manual or automatic, are available for release of the agent into the hazard area. The agent is distributed and discharged into the hazard area through a network of piping and nozzles. Each nozzle is drilled with a fixed orifice designed to deliver a uniform discharge to the protected area. On large hazards, where three or more cylinders are required, a screwed or welded pipe manifold assembly is employed. The cylinder(s) is connected to the distribution piping or the manifold by means of a flexible discharge bend and check valve assembly. Additional equipment includes - Control panels, releasing devices, remote manual pull stations, corner pulleys, door closures, pressure trips, bells and alarms, and pneumatic switches. All or some are required when designing a total system. INERGEN Agent - INERGEN agent is a mixture of three inerting (oxygen diluting) gases: 52% nitrogen, 40% argon, and 8% carbon dioxide. INERGEN gas extinguishes fire by lowering the oxygen content below the level that supports combustion. When INERGEN agent is discharged into a room, it introduces the proper mixture of gases that still allow a person to breathe in a reduced oxygen atmosphere. It actu- ally enhances the body's ability to assimilate oxygen. The normal atmos- phere in a room contains 21% oxygen and less than 1% carbon dioxide. If the oxygen content is reduced below 15%, most ordinary combustibles will cease to burn. INERGEN agent will reduce the oxygen content to approximately 12.5% while increasing the carbon dioxide content to about 3%. The increase in the carbon dioxide content increases a person's respiration rate and the body's ability to absorb oxygen. Simply stated, the human body is stimulated by the carbon dioxide to breathe more deeply and rapidly to compensate for the lower oxygen content of the atmosphere. Cylinders - The cylinders are constructed, tested, and marked in accor- dance with applicable Dept. of Transportation (DOT) and the U.S. Bureau of Explosives specifications. As a minimum, the cylinders must meet the requirements of DOT 3AA2300 or 3AA2015+. Cylinder Assembly - The cylinder assembly is of steel construction with a red standard finish. Four sizes are available to meet specific needs. Each is equipped with a pressure seat-type valve equipped with gauge. The valve is constructed of forged brass and is attached to the cylinder providing a leak tight seal. The valve also includes a safety pressure relief device which provides relief at 2900-3300 psi (20685-23167 kPA) per CGA test method. Cylinder charging pressure is 2175 psi at 70°F (14997 kPAat 21 °C). The cylinders are shipped with a maintenance record card and shipping cap attached. The cap is attached to the threaded collar on the neck of each cylinder to protect the valve while in transit. The cylinder serial number and date of manu- facture are stamped near the neck of each cylinder. Electric Actuator - Electric actuation of an agent cylinder is accom- plished by an electric actuator interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous environments where the ambient temperature range is between 32 OF and 130 OF (0 °C and 54 °C). In auxiliary or override applications, a manual lever actuator can be installed on top of the actuator. Manual or Pneumatic Actuators - Manual/pneumatic actuators are available for lever actuation on the cylinder valve. Manual actuation is accomplished by pulling the hand lever on the actuator. Detection System -The AUTOPULSE Control System is used where an automatic electronic control system is required to actuate the INERGEN system. This control system is used to control a single fixed fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The control system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices. Nozzles - Nozzles are designed to direct the discharge of INERGEN agent using the stored pressure from the cylinders. Ten sizes of nozzles are available. The system design specifies the nozzle and orifice size to be used for proper flow rate and distribution pattern. The nozzle selec- tion depends on the hazard and location to be protected. Pressure Reducer - The pressure reducer is required in the distribution piping to restrict the flow of INERGEN agent, thus reducing the agent pressure down stream of the reducer. The pressure reducer contains a stainless steel orifice plate which is drilled to the specific size hole required based on the hydraulic calculation. The orifice plate provides readily visible orifice identification. The pressure reducer is available in nine sizes: 1/2 in., 3/4 in., 1 in., 1 1/4 in., 1 1/2 in., 2 in., 2 1/2 in., 3 in., and 4 in. NPT.