HomeMy WebLinkAbout2035 CORTE DEL NOGAL; ; AS110009; Permit6/2/22, 1:45PM AS110009 Permit Data
City of Carlsbad
Sprinkler Permit
2035 CORTE DEL
Job Address:
NOGAL
Permit Type: SPRINK
Parcel No: 2130611000
Lot #: 0
Reference No.:
PC #:
Permit No: ASI10009
Status: ISSUED
Applied 1/20/2011
Approved: 1/20/2011
Issued: 1/20/2011
Inspector:
Project Title: BY REFERRAL ONLY T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant: Owner:
BOI CARLSBAD INC
C/O LYNN MINNICI
P0 BOX 121604
ARLINGTON TX
Fees ($) Add'I Fees ($) Total ($) Balance ($)
L 130 0 130 0
1/1
QUICK RESPONSE
RECESSED PENDENT
QUICK RESPONSE
RECESSED
HORIZONTAL SIDEWALL
Asiwoi
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
FIRE SPRINKLER CORPORATION
DESCRIPTION AND OPERATION
The Globe Quick Response GL Series Sprinkler is a low profile
yet durable design which utilizes a 3mm frangible glass ampule as
the thermosensitive element. This provides sprinkler operation
approximately six times faster than ordinary sprinklers. While the
Quick Response Sprinkler provides an aesthetically pleasing ap-
pearance, it can be installed wherever standard spray sprinklers
are specified but offers the additional feature of greatly increased
safety to life. Quick Response Sprinklers should be used advisedly
and under the direction of approving authorities having jurisdiction.
The heart of Globe's CL Series sprinkler proven actuating
assembly is a hermetically sealed frangible glass ampule that
contains a precisely measured amount of fluid. When heat is
absorbed, the liquid within the bulb expands increasing the internal
pressure. At the prescribed temperature the internal pressure
within the ampule exceeds the strength of the glass causing the
glass to shatter. This results in water discharge which is distributed
in an approved pattern depending upon the deflector style used.
The sprinkler nd escthcCeon are not faciory aeitbd.
Assembly is done in the field.
TECHNICAL DATA
'See reverse side for Approvals and Specifications.
eTemperature Ratings - 135°F (57°C), 155°F (68°C), 175°F
(79°C), 200°F (93°C), 286°F (141°C).
'Water Working Pressure Rating - 175 psi (12 Bars).
'Factory tested hydrostatically to 500 psi (34 Bars).
Maximum low temperature glass bulb rating is -67°F (-55°C).
'Frame - bronze o Deflector - brass o Screw - brass
'Bulb seat - copper o Spring - nickel alloy • Seal - teflon
'Bulb - glass with alcohol based solution, 3mm size.
Escutcheon Assembly - steel
SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING
1 AVAILABLE SPRINKLER 1 BULB N.F.P.A. MAXIMUM CLASSIFICATION ' TEMPERATURES I COLOR CEILING TEMPERATURE
ORDINARY 135'F/1 55°1` 57°C168°C ORANGE/RED 100°F. 38°C
INTERMEDLTE 175°F1200°F 79°C/93°C YELLOW/GREEN 150°F 66°C
HIGH 286°F 141°C BLUE 225°F - 107°C
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231
DECEMBER 2006 A-24 BULLETIN GL2801, REV. #5
f
2' DK MIN IN ~IM
I Il-I 29/32 D. fl/_ IJi.
RETAINER
-
NINN (
I/6 M31.
7/s. tc
PENDENT I i IS/Ir Q I3I& I 29/32-
'mr" 'r
RUNNM
:" I
cç7 •V-EP HORIZONTAL
SIDEWALL
FIRE SPRINKLER CORPORATION
WICK RESPONSE
L UTOMA TIC SPRINKLERS
UL- SERIES
RECESSED PENDENT
RECESSED HORIZONTAL SIDEWALL
SPECIFICATIONS
NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES
2.8 (39 metric) 1/2" NPT 2 1/4' (5.7 cm) Factory Bronze
4.2 (59 metric) 1/2" NPT 2 1/4' (5.7 cm) Satin Chrome 2 Bright Chrome
5.6 (80 metric) 1/2 NPT 2 1/4" (5.7 cm) White Polyester
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2
NOTE: METRIC CONVERSIONS ARE APPROXIMATE. HORIZONTAL SIDEWALL IS 2 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER.
3C-UL LISTED CORROSION RESISTANT -
POLYESTER MUST BE SPECIFIED ON ORDER.
APPROVALS
STYLE SIN
MODEL
1<
FACTOR
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
°286°F
141°C cULus FM LPC CE NYC - DOB
MEAIOI-92-E
GL2801 2.8 X X X X X X - - - X
GL4201 4.2 X X X X X X - - - x
PENDENT GL5601 5.6XX X X X X X X RECESSED
HORIZONTAL GL4226 4.2 X X X X X X - - X
SIDEWALL
RECESSED 5 GL5626 5.6 X X X X X X - X
GL8127 8.1 X X X X X X - - -
§ HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4° TO 12" BELOW THE CEILING.
t 5.6K ORIFICE, 7.8K ORIFICE AND 8.1 K ORIFICE LISTED FOR ALL HAZARDS.
C . 7.8K X 1/2" NPT. ROSS SECTIONS °°286°F cULus LISTED ONLY.
t t 1/2° RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS.
ORDERING INFORMATION
SPECIFY
Quantity • Model Number • Style
Orifice • Thread Sizes • Temperature
Finishes desired
° Quantity - Recessed Wrenches - P/N 325391 (1/2");
P/N 325401, Rev. F (L.a.)
Quantity - Protective Caps - P/N 327109-CAP
(Friction Fit Recessed)
GLOBE® PRODUCT WARRANTY
I) Globe agrees to repair or replace any of its own
manufactured products found to be defective in material
or workmanship for a period of one year from date of
I3/•293 shipment.
For specific details of our warranty please refer to
Price List Terms and Conditions of Sale (Our Price List).
4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658
989-846-4583 FAX 989-846-9231
1-800-246-0278 www.globesprinkIer.com
DECEMBER 2006 PRINTEDU.S.A. BULLETIN GI-2801, REV. #5