Loading...
HomeMy WebLinkAbout2509 PALOMAR AIRPORT RD; ; AS130055; Permit6/13/22, 4:40 PM AS130055 Permit Data City of Carlsbad Sprinkler Permit 2509 PALOMAR Job Address: AIRPORT RD Permit Type: SPRINK Parcel No: 2130201800 Lot #: 0 Permit No: AS130055 Status: ISSUED Applied 4/23/2013 Approved: 6/13/2013 Reference No.: Issued: 6/13/2013 PC #: Inspector: Project Title: ACACIA FUEL STATION NEW COMMERCIAL FIRE SPRINKLER SYSTEM Applicant: RICE FIRE PROTECTION 24300 VERA LANE MORENO VALLEY, CA 951-243-6677 Owner: COUNTY OF SAN DIEGO PUBLIC AGENCY Fees ($) Add'I Fees ($) Total ($) Balance ($) 1,511 0 1,511 0 1/1 Apr.1.2013 10:08 17602408695 PAGE. 2/ 5 Hydrant Flow Test Report Test Date 4/1/2013 Test Time 9:15am Location Tested by 2515 Palomar Airport Road. FIRE CODE Carlsbad, CA 63 Via Pica Plaza #102 San Clemente, CA 92672 (949) 369-1000 office (949) 682.2255 fax info@firecodeinc.com Notes Read Hydrant Read Hydrant at corner of Palomar Airport & El 116 psi static pressure Camino Real 111 psi residual pressure Flow Hydrant 400 feet South on El Camino Real 100 ft hydrant elevation Outlet Elev #1 100 Flow Hydrant(s) Pitot Size C Pressure 25 Flow Graph Flow 1350 gpm 125 100 75 - psi .- 50 25 OLL 0 1500 66682 gpm at 20 psi 3000 4500 6000 gpm craoted v.lth the free hydrant flow tact program from wwwgneu4nc.com Apr.1.2013 10:08 17602408695 PAGE. 3! 5 I Carlsbad Municipal Water District Potable Water Discharge Event Report Date VO Location: Uk! Reason for Discharge Event: Type of Event Initial Dewatering Water Mains NoteIncludes tow testing and flushing Dewatering Water Mains Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. _3 S Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharged water. A1€+ 0-d. Estimated Discharge Flow: GPM Start Time End Time Pre-Dechlonnation Residual: PostDechlôrination Residual: (Less than 0.1 mg/L) PH within limits of 8.0 and 9.0 .S Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediments or silted areas are cleared. Water Sampling Performed by: Comments: Submitted by: Reviewed by: (Name & Date) (Name & Date) RICE FIRE PROTECTION 24300 VERA LANE MORENO VALLEY,CA 92557 HYDRAULIC CALCULATIONS FOR CARLSBAD CAR WASH FILE NUMBER: DATE: APR 16, 2013 -DESIGN DATA- OCCUPANCY CLASSIFICATION: ORDIANRY GROUP II DENSITY: .20 AREA OF APPLICATION: 1500 COVERAGE PER SPRINKLER: 124 NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) SPRINKLER ORIFICE SIZE: 1/2 NAME OF CONTRACTOR: DESIGN/LAYOUT BY: chris AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: gpm/sq. ft. sq. ft. sq. ft. 13 sprinklers 319.5 gpm 569.6 gpm gpm @ psi inch CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 27031226 HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SCR 116.0 111.0 1350.0 115.0 569.6 86.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 569.6 GEM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 319.6 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GEM) 1 13.6 - - - - 19.8 - - - 2 13.6 K= 5.60 18.7 24.2 3 13.6 K= 5.60 18.4 24.0 4 13.6 K= 5.60 18.4 24.0 5 13.6 K= 5.60 18.6 24.1 6 13.6 K= 5.60 19.5 24.7 7 13.6 - - - - 33.5 8 13.6 - - - - 20.0 - - - 9 13.6 K= 5.60 18.9 24.3 10 13.6 K= 5.60 18.6 24.1 11 13.6 K= 5.60 18.6 24.1 12 13.6 K= 5.60 18.8 24.3 13 13.6 K= 5.60 19.7 24.8 14 13.6 - - - - 33.9 - - - 15 13.6 - - - - 20.8 - - - 16 13.6 K= 5.60 20.7 25.5 17 13.6 K= 5.60 20.7 25.5 18 13.6 K= 5.60 21.3 25.8 19 13.6 - - - - 35.2 - - - 20 13.6 - - - - 21.9 - - - 21 13.6 - - - - 38.0 - - - 22 13.6 - - - - 22.1 - - - 23 13.6 - - - - 41.2 TOR 13.6 - - - - 61.1 BOR 1.0 - - - - 74.0 - - - A -3.0 - - - - 76.1 - - - DC2 2.5 - - - - 76.4 - - - DC1 2.5 - - - - 82.5 - - - SCR -3.0 SOURCE 86.6 319.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 51.5 1.536 PL 2.90 PF 1.1 1 13.6 0.0 19.8 0.0 8.9 120 FTG T PE 0.0 2 13.6 5.6 18.7 24.2 0.117 TL 9.26 PV Pipe: 2 27.3 1.536 PL 8.20 PF 0.3 2 13.6 5.6 18.7 24.2 4.7 120 FTG ---- PE 0.0 3 13.6 5.6 18.4 24.0 0.036 TL 8.20 PV Pipe: 3 3.3 1.536 PL 10.00 PF 0.0 3 13.6 5.6 18.4 24.0 0.6 120 FTG ---- PE 0.0 4 13.6 5.6 18.4 24.0 0.001 TL 10.00 PV Pipe: 4 -20.7 1.536 PL 8.80 PF 0.2 4 13.6 5.6 18.4 24.0 3.6 120 FTG ---- PE 0.0 5 13.6 5.6 18.6 24.1 0.022 TL 8.80 PV Pipe: 5 -44.8 1.536 PL 10.00 PF 0.9 5 13.6 5.6 18.6 24.1 7.8 120 FTG ---- PE 0.0 6 13.6 5.6 19.5 24.7 0.090 TL 10.00 PV Pipe: 6 -69.5 1.536 PL 62.40 PF 14.0 6 13.6 5.6 19.5 24.7 12.0 120 FTG T PE 0.0 7 13.6 0.0 33.5 0.0 0.203 TL 68.76 PV Pipe: 7 51.5 2.203 PL 11.30 PF 0.2 8 13.6 0.0 20.0 0.0 4.3 120 FTG ---- PE 0.0 1 13.6 0.0 19.8 0.0 0.020 TL 11.30 PV Pipe: 8 51.8 1.536 PL 2.90 PF 1.1 8 13.6 0.0 20.0 0.0 9.0 120 FTG N PE 0.0 9 13.6 5.6 18.9 24.3 0.118 TL 9.26 PV Pipe: 9 27.4 1.536 PL 8.20 PF 0.3 9 13.6 5.6 18.9 24.3 4.8 120 FTG ---- PE 0.0 10 13.6 5.6 18.6 24.1 0.036 TL 8.20 PV Pipe: 10 3.3 1.536 PL 10.00 PF 0.0 10 13.6 5.6 18.6 24.1 0.6 120 FTG ---- PE 0.0 11 13.6 5.6 18.6 24.1 0.001 TL 10.00 PV Pipe: 11 -20.8 1.536 PL 8.80 PF 0.2 11 13.6 5.6 18.6 24.1 3.6 120 FTG ---- PE 0.0 12 13.6 5.6 18.8 24.3 0.022 TL 8.80 PV Pipe: 12 -45.1 1.536 PL 10.00 PF 0.9 12 13.6 5.6 18.8 24.3 7.8 120 FTG ---- PE 0.0 13 13.6 5.6 19.7 24.8 0.091 TL 10.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH. SDF JOB TITLE: CARLSBAD CAR WASH PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -70.0 1.536 PL 62.40 PF 14.2 13 13.6 5.6 19.7 24.8 12.1 120 FTG N PE 0.0 14 13.6 0.0 33.9 0.0 0.206 TL 68.76 PV Pipe: 14 69.5 2.203 FL 11.30 PF 0.4 14 13.6 0.0 33.9 0.0 5.9 120 FTG ---- FE 0.0 7 13.6 0.0 33.5 0.0 0.035 TL 11.30 PV Pipe: 15 103.3 2.203 PL 10.90 PF 0.8 15 13.6 0.0 20.8 0.0 8.7 120 FTG ---- FE 0.0 8 13.6 0.0 20.0 0.0 0.073 TL 10.90 FV Pipe: 16 15.8 1.536 FL 2.90 PF 0.1 15 13.6 0.0 20.8 0.0 2.7 120 FTG N FE 0.0 16 13.6 5.6 20.7 25.5 0.013 TL 9.26 PV Pipe: 17 -9.7 1.536 FL 8.20 PF 0.0 16 13.6 5.6 20.7 25.5 1.7 120 FTG ---- PE 0.0 17 13.6 5.6 20.7 25.5 0.005 TL 8.20 PV Pipe: 18 -35.2 1.536 FL 10.00 PF 0.6 17 13.6 5.6 20.7 25.5 6.1 120 FTG ---- PE 0.0 18 13.6 5.6 21.3 25.8 0.058 TL 10.00 FV Pipe: 19 -61.0 1.536 PL 81.00 PF 14.0 18 13.6 5.6 21.3 25.8 10.6 120 FTG N FE 0.0 19 13.6 0.0 35.2 0.0 0.160 TL 87.36 PV Pipe: 20 139.5 2.203 PL 10.90 PF 1.4 19 13.6 0.0 35.2 0.0 11.7 120 FTG ---- FE 0.0 14 13.6 0.0 33.9 0.0 0.127 TL 10.90 FV Pipe: 21 119.1 2.203 FL 11.80 PF 1.1 20 13.6 0.0 21.9 0.0 10.0 120 FTG ---- FE 0.0 15 13.6 0.0 20.8 0.0 0.095 TL 11.80 PV Pipe: 22 -56.8 1.536 PL 102.00 PF 16.1 20 13.6 0.0 21.9 0.0 9.8 120 FTG 2N PE 0.0 21 13.6 0.0 38.0 0.0 0.140 TL 114.72 PV Pipe: 23 200.4 2.203 PL 11.00 PF 2.7 21 13.6 0.0 38.0 0.0 16.9 120 FTG ---- FE 0.0 19 13.6 0.0 35.2 0.0 0.249 TL 11.00 PV Pipe: 24 62.3 2.203 FL 8.11 PF 0.2 22 13.6 0.0 22.1 0.0 5.2 120 FTG ---- PE 0.0 20 13.6 0.0 21.9 0.0 0.029 TL 8.11 PV Pipe: 25 -62.3 1.536 FL 102.00 PF 19.1 22 13.6 0.0 22.1 0.0 10.8 120 FTG 2T FE 0.0 23 13.6 0.0 41.2 0.0 0.166 TL 114.72 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 26 257.3 2.203 PL 8.11 PF 3.2 23 13.6 0.0 41.2 0.0 21.7 120 FTG ---- PE 0.0 21 13.6 0.0 38.0 0.0 0.396 TL 8.11 PV Pipe: 27 319.5 2.203 PL 20.00 PF 19.9 TOR 13.6 0.0 61.1 0.0 26.9 120 FTG 2E PE 0.0 23 13.6 0.0 41.2 0.0 0.591 TL 33.64 PV Pipe: 28 319.5 2.203 PL 12.60 PF 7.4 BOR 1.0 0.0 74.0 0.0 26.9 120 FTG ---- PE -5.5 TOR 13.6 0.0 61.1 0.0 0.591 TL 12.60 PV Pipe: 29 319.5 4.220 PL 5.00 PF 0.4 A -3.0 0.0 76.1 0.0 7.3 140 FTG E PE -1.7 BOR 1.0 0.0 74.0 0.0 0.019 TL 22.00 PV Pipe: 30 319.5 4.240 PL 108.00 PF 2.7 DC2 2.5 0.0 76.4 0.0 7.3 150 FTG 3E PE 2.4 A -3.0 0.0 76.1 0.0 0.016 TL 168.00 PV Pipe: 31 FIXED PRESSURE LOSS DEVICE DC1 2.5 0.0 82.5 0.0 6.1 psi, 319.5 gpm DC2 2.5 0.0 76.4 0.0 Pipe: 32 319.6 4.240 PL 22.00 PF 1.7 SCR -3.0 SRCE 86.6 (N/A) 7.3 150 FTG 2ETG PE -2.4 DC1 2.5 0.0 82.5 0.0 0.016 TL 105.00 PV NOTES (HASS) Calculations were performed by the HASS 8.3 computer program under license no. 27031226 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.147 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 26.9 ft/sec at pipe 28. a. System remote area HAS been proven or 'peaked'. Minimum pressure at any sprinkler: 18.367 psi Minimum pressure with remote area shifted one sprinkler space toward right cross main: 18.458 psi SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HA5583\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH d. Remote area is located adjacent to left cross main Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SCR under full flow conditions is 114.78 psi compared to the minimum required pressure of 20.00 psi. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkViv BfyVlv GatViv AlmChk DPViv NPTee 1.536 3.18 6.36 1.59 7.16 4.77 0.80 7.95 7.95 6.36 2.203 6.82 13.64 4.09 15.00 8.18 1.36 13.64 13.64 13.64 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEll ChkViv BfyVlv GatViv NPTee 4.220 17.00 34.00 10.00 37.00 20.00 3.00 34.00 PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEll ChkVlv BfyVlv GatVlv NPTee 4.240 20.00 39.00 12.00 43.00 23.00 4.00 39.00 E a 0 0 u) H 0 H U) Q4 0 0 H H H U) (1) H U) H 0 I-lw U 0 0 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH E @Q) a 00 14 OJI OD U)LI) 04 (0 -I) U) Q) a H a HU)E Z H04 U)OU) .0 (Ua )-i i0 I:rl H H -H('O> rH U).D F1:- QDU) H JI 0 0 0 0 0 0 H 0 (N w 0 00 U) (N W W aU)-H-- 0 - 0 0 0 0 H I. 0 <14> 69.5 <20> 139.5 (23> 200.4 (26> 257.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH WATER SUPPLY CURVE 120+ I \\\\\\\\\\\\\\\ 110+ * <-111.0 Psi @ 1350 gpm I Flow Test Point 100+ 90+ I X P 80+ R I E I S I 5 70+ U I R E I 60+ P I S I 50+ 40+ 30+ 20+ LEGEND I X = Required Water Supply I 86.62 psi @ 569.6 ppm 10+ I 0 = Available Water Supply 114.99 psi @ 569.6 ppm 0++-+---+----+-----+ ------+--------+ --------+---------+ -----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 4/16/2013 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\CARLSBAD CARWASH.SDF JOB TITLE: CARLSBAD CAR WASH GRID FLOW DIAGRAM [XXX] - Node Numbers 71 A 51.6 27.4 3.4 20.6 44.7 69.5 51.5 69.5 A A 141 A 51.8 27.5 3.4 20.8 45.1 69.9 A 103.3 139.4 A A --------------[ 19] A 15.8 9.6 35.1 60.9 A 119.0 200.4 A A 201 ----------------- - ----------------- II 211 A 56.8 A 62.2 257.2 A A 221 ----------------- - ----------------- [ 231 62 .2 Worldwide Contacts www.tyco-fire.com Series TY-FRB 2.8, 4.2f 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright. Pen- dent, and Recessed Pendent Sprin- klers described in this data sheet are quick response, standard coverage. decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels and shop- ping malls. The recessed version of the Series TY- FRB Pendant Sprinkler, where applica- ble, is intended for use In areas with a finished ceiling. This recessed pendant sprinkler uses one of the following: A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendant position, or a A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch 6,4 rm'i of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendant position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the 'INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 spheres. Although corrosion- resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The affects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklerswillbe exposed. An intermediate level of the Series TY- FRB Pendant Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP7SO. The Series TY-FRB Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices- The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. MARCH 2013 Sprinkler Identification Number (SIN) TY1131: Upright 2.8K,.1/2"NPT TY1231: Pendant 2.8K, 1/2" NPT TY2131: Upright 4.2K,1/2"NPT 1Y2231: Pendent 4.2K,1/ZNPT TY3131: Upright 5.6K, 1/2 NPT TY3231: Pendent 5.6K, 1/2' NPT TV4131: Upright 8.0K, 3/4'NPT 1Y4231: Pendant 8. OK, 3/4NPT TY4831: Upright* 8.0K, 1/2' NPT TY4931: Pendent* 8.0K, 1/2" NPT 'Eastern Hemisphere Sales Only TFP 171 2-718" (73,0 mm) DIA. ---j RECESSED PENDENT TFPI7I Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button DefIetor special request. PLATE SEATING SURFACE 7/16" (11,1mm) NOMINAL 2-1/411 71 112 NPT** WRENCH STYLE 10 0r20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing CROSS SECTION - 2-7/8' (73,0 mm) DIA RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TYI 131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE r'J7 NOMINAL MAKE-IN (55,6 MM4 ______ 1/21,NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 1 Frame 3 - Sealing 5 - Compression 2 Button Assembly Screw 4 - Bulb 6 Deflector* III CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2I3I) AND PENDENT (TY2231) SPRINKLERS 4,2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 3of 10 * Temperature rating Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON De ector. special request. PLATE SEATING SURFACE 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - De ector* NOMINAL 2-3 1/2 NPT** WRENCH STYLE 10 or 20 -2-7/8 (73,0 mm) DIA. ............ UPRIGHT FLATS RECESSED PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('TY3131) AND PENDENT (TY3231) SPRINKLERS 56 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Dc actor. special request. PLATE SEATING 4 - Bulb 6 - De ector* SURFACE ?1/2 (127mm) __ 26 9 I 2-1/4 "jL II ijl 1-9/16 (57,2 mm) (39,7 mm) 3/4 NPT WRENCH STYLE 30 0r40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 2-7/8 (73,0 mm) DIA, RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (1Y4 131) AND PENDENT (TY4231) SPRINKLERS ao K-FACTOR, 3/4 INCH NPT TFPI7I Page 4 of 10 CE LING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 3 - Sealing 6 - Dc ector * Assembly lb NOMINAL 2 Tcej er. ind 5 Pipe. thread connertions :+ per ISO 7i can be provided on special 1/2 NPT** . WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT ('TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K2.8 GPM/ps1112 (40,3 LPM/bar112) K4.2 GPM/psi1' (60.5 LPM/bar1 ) K=5.6 GPM/ps1112 (80,6 LPM/bar1 ) K=8.0 GPM/psi112 (115,2 LPM/har1 ) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated Chrome Plated, or Brass Plated. Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Beryllium Nickel wJTEFLON Bulb ......................Glass Compression Screw........Bronze De ector...........Copper/Bronze Bushing X=2.8) ...........Bronze Operation The glass bulb contains a uld that expands when exposed to heat. When the rated temperature is reached, the uld expands suf ciently to shatter the glass bulb, allowing the sprinkler to activate and water to ow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor. Upright, Pen- dent, and Recessed Pendent Sprinklers are intended for re protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as. UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30. or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklersmust be installed in accordance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm)for the 135 F (57 C)and 3/32 inch ,4 mm)for the 286 F (141 C) temperature ratings. A leak-tight 112 inch NPT sprinkler joint shold be obtained by applying a min- imum to maximum torque of 7 to 14 ft.l-bs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insuf dent adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler tting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler tting. Step 3. Tighten the sprinkler into the sprinkler tting using only the W-Type 6 Sprinkler Wrench (Figure 14). With refer- ence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the spun- kier wrench ats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, overthe sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler tting. Step B. Tighten the sprinkler into the sprinkler tting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 15). With reference to Figures 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench ats. Step C. After ceiling installation and fishing, slide on the Style 10, 20, 30, 0r40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its ange comes in contact with the ceiling. TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE 2.8 1/2" NPT PENDENT (1 Y123 1) and UPRIGHT (TVI131) 135 F(57 C) Orange 1,2, 3,4 155 F (68 C) Red 175 F(79 C) Yellow 200 F(93 C) Green 286 F (141 C) Blue RECESSED PENDENT (TV1231)* Figure 6 135 F(57 C) Orange 1,2,4 155 F (68 C) Red 175 F(79 C) Yellow 200 F (93 C) Green RECESSED PENDENT (1Y1231)** Figure 7 135 F(57 C) Orange 155 F (68 C) Red 175 F(79 C) Yellow 200 F (93 C) Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135 F(57 C) Orange 1,2 155 F (68 C) Red 175F(79C) Yellow 200 F(93 C) Green 286 F (141 C) Blue RECESSED PENDENT (TY2231) Figure 8 135 F(57 C) Orange 155 F (68 C) Red 175 F (79 C) Yellow 200 F(93 C) Green RECESSED PENDENT TY2231)** Figure 9 135 F(57 C) Orange 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green NOTES: Listed by Underwriters Laboratories, Inc., (UL)as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3 Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-ULListed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2 NPT) or Style 40 (3/4 NPT) 3/4 Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 NPT) or Style 30(3/4 NPT) 1/2 Total Adjustment Recessed Escutcheon, as applicable. Frame and Do ector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE 4 LABORATORY LISTINGS AND APPROVALS FOR 28 A ND 42 K-FA CTOR SPRINKLERS TFPI7 I Page 6of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED I SIGNAL*** WHITE LEAD COATED 5.6 1/2" NPT PENDENT (TY3 231) and UPRIGHT (TY3 131) 135 F(57 C) Orange 1,2,3,4,5,6, 7 286 F (141 C) Blue 1,2,3.5 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green RECESSED PENDENT (TY3231)* Figure 10 135 F(57 C) Orange 1, 2,4, 5 286 F (141 C) Blue N/A 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green RECESSED PENDENT (TY3 231)** Figure 11 135 F(57 C) Orange 1, 2, 3,4, 5 286 F (141 C) Blue N/A 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green 8.0 3/4" NPT PENDENT (1Y4231) and UPRIGHT TY4131) 135 F(57 C) Orange 1. 2,3,4,5,6,7 286 F (141 C) Blue 1,2,5 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green RECESSED PENDENT (TY4231)* Figure 12 RECESSED PENDENT (TY4231)I* Figure 13 135 F(57 C) Orange 155 F (68 C) Red 1, 2, 5 1, 2, 3, 5 286 F(141 C) Blue 286 F (141 C) Blue N/A N/A 175 F (79 C) Yellow 200 F (93 C) Green 135 F(57 C) Orange 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green 80 112" NPT PENDENT tTY4931) and UPRIGHT (TY4831) 135 F(57 C) Orange 1,2,4,5,6 286 F (141 C) Blue 1,2,5 155 F (68 C) Red 175 F (79 C) Yellow 200 F (93 C) Green NOTES: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certi cation Board (LPCB Ref.No. 007k/04)as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York underMEA 354-01-E. VdS Approved (For details, contact Tyco File Suppression & Building Products, Enschede, Netherlands. Tel. 31-53-428-4444/Fax 31-53-428-3377.) Approved by the Loss Prevention Certi cation Board (LPCB Ref. No. 094a/06)as Quick Response Sprinklers. B. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion- Resistant Sprinklers. Installed with Style 10(1/2 NPT) or Style 40 (3/4 NPT) 3/4 Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 NPT) or Style 30(3/4 NPT) 1/2 Total Adjustment Recessed Escutcheon, as applicable. Frame and De ector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FA OTOR SPRINKLERS TFPI7I Page 7of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I SIGNAL LEAD FACTOR BRASS PLATED WHITE COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT )TY2131) 1/2" NPT 175 PSI (12,1 EAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI 5.6 and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 1/2" NPT OR 175 PS (12,1 BAR) RECESSED (SEEN OTE 1) N/A PENDENT (TY3231) PENDENT (TY4231) 175 PSI 8.0 and UPRIGHT (TY4131) (12,1 BAR) 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI 1/2" NPT and UPRIGHT (TY4831) 175 PSI (12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL) the Listing by Underwriters Laboratories, Inc, for use in Canada (C-UL) and, the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a re protection system main control valve for maintenance work on the re protection system that it controls, obtain permission to shut down the affected re protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a re situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modi ed sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping. striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their re protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a quali ed Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suf Ce. Inspections of corrosion-resistant sprinklers are recommended at close range, instead of from the oor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion-resistant material. which can be affected by the corrosive conditions present. TFPI7 I Page 8 of 10 2-7/8 DI A. 5/8 114" (73,0 mm) 3/4" (19,1 mm) (15.9 6,4 mm) 2-1/4 Dl A. - 7 FACE OF , (57,2 mm) 9_I MOUNTING SPRINKLER PLATE RUING . F Il 1/8' (3,2 mm) MOUNTING SURFACE / CLOSURE SERIES 1-5/16 (33,3mm) TY-FRB 13/16' (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2,8 K-FACTOR, 1/2 INCH NPT 2-7/8' DI A. 5/8 1/4" (73,0 mm) 3/4" (19,1 mm) (15,9 6,4 mm) 2-1/4" DA / (57,2mm) FACE OF . MOUNTING SPRINKLER \ / .- PLATE FITTING 1. J ::mi (3,2 mm) MOUNTING _SURFACE __ * SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 2-7/8' DI A. 1/2 1/8" (730 mm) 1/2 (12,7 mm) (12,7 3,2 mm) 2-114"DIA. j 1/4(6,4mm) / [ (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING ( 1- -7 (3,2 mm) F77 7/ '-A ........ MOUNTING ___ SURFACE / CLOSURE SERIES 1-5/16 (33,3 mm)) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2,8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA 112 1/8" (73,0 mm) 1/2" (12,7 mm) (12,7 3,2mm) 2-1/4" DI A. / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE PITTING - r I It 1/8" (3.2 mm) /t MOUNTING / SURFACE/ / SERIES 1-1/4" 131,8 mm) CLOSURE lY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7 I Page 9 of 10 2-7/8 DI A. 5/8 1/4" (73,0 mm) " 3/4" (19,1 mm) (15,9 64mm) 2-1/4" DA 1/4 (6,4 mm) FACE OF (57,2mm) MOUNTING SPRINKLER \ / - PLATE FITTING -(I- - / - I (3,2 mm) MOUNTING SUREAC ,/ I SERIES 1-1/4 (318 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8 DA. 5/8 1/4 (73,0 mm) 3/4" (19,1 mm) (15,9 6,4mm) 2-1/4"DIA. 1/4" (6,4 mm) I / FACE OF (57,2 mm) MOUNTING SPRINKLER c L— PLATE FITTING (3,/ mm MOUNTING / SURFAC , // ..................................................... CLOSURE SERIES 1-5116" (33,3 TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 2-7/8 DI A. 1/2 1/8 (73,0 mm) , mm (12,7 3,2 mm) 2-114'DIA. 1/4"(6,4 mm) / FACE OF , (5 72 mm) MOUNTING SPRINKLER f PLATE FITTING (32mm) MOUNTING // I SURFACE / CLOSURE SERIES 1-114"(31,8 mm) l TY-FRB 1" (25,4 mm) FIGURE II SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FA CTOR, 1/2 INCH NPT 2-7/8 DI A. (73,0 mm) 1/2' (12,7 mm), 1/2 118" (12,7 32mm) 2-114"DIA. 1/4 (6,4 mm) / FACE OF I MOUNTING SPRINKLER L. .a PLATE FITflNG rL_j (32 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm TY-FRB 1-1/16 (27,0 mm) FIGURE 13 SERIES 1Y-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS I PUSH WRENCH IN 10 ENSURE ENGAGEMENT WTH SPRINKLER WRENCHING AREA FIGURE 15 W- TYPE 7 RECESSED SPRINKLER WRENCH 1 NATURAL BRASS PURE WHITE (RAL9O1O)* SIGNAL WHITE (RALS003) 7 LEAD COATED 9 CHROME PLATED JET BLACK (RAL9005) *Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155 F(68 C)and 200 F(93 C) requires lead time tomanufacture. TFPI7I Page 10 of 10 P/N 57 XXX X XXX SPRIN KLER SIN FINISH TEMPERATURE _J_ RATINGS 135 135 F(57 C) 155 155 F (68 C) 175 175 F (79 C) 200 200 F(93 C) 286 286 F (141 C) 330 2.8KUPRIGHT(1/2 NPT) TY1131 331 2.8K PENDENT (1/2 NPT) 1Y1231 340 4.2K UPRIGHT (1/2 NPT) 1(2131 341 4.2K PENDENT (1/2 NPT) TY2231 370 5.6K UPRIGHT(1/2 NPT) TY3131 371 5.6K PENDENT (1/2 NPT) 1Y3231 390 8 OK UPRIGHT (3/4 NPT) TY4131 391 8.0K PENDENT (3/4 NPT) TY4231 360 8.0K UPRIGHT (1/2 NPT) TY4831* 361 8.0K PENDENT (1/2 NPT) TY4931 TABLED SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Pail Number (PIN). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) tempera- ture rating, (specify) fish or coating. P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify) nish, P/N (specify). Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench. P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench. P/N 56-850-4-001. Refer to Technical Data Sheet TFP770. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright 2013Tyco Fire Products, LP. All rights reserved. tLIcD TEFLON is trademark of The DuPont Corporation.