HomeMy WebLinkAbout2051 PALOMAR AIRPORT RD; ; FA020018; Permit6/13/22, 4:38 PM FA020018 Permit Data City of Carlsbad Fire Alarm Permit 2051 PALOMAR Job Address: AIRPORT RD Permit Type: FALARM Parcel No: 2130503900 Lot #: 0 Reference No.: PC #: Project Title: MELLES GRIOT Permit No: FA020018 Status: ISSUED Applied 5/31/2002 Approved: 6/3/2002 Issued: 6/3/2002 Inspector: Applicant: Owner: MG PALOMAR L L C C/O SHAH ID A KHWAJA 2051 PALOMAR AIRPORT RD #200 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 90 0 90 0 1/1 FA02-0 c>tS r4r.. CONSTRUCTION ELECTRONICS N C 0 P P 0 P A T P D Melles Griot 2051 Palomar Airport Road Carlsbad, CA 92008 PFN: CB020257 Equipment Submittal for Alarm for Fire Smoke Damper Activation and HVAC Unit Monitoring Prepared by: Construction Electronics, Inc. 13715 Stowe Drive Poway, CA 92064 May 30, 2002 '4? S 0 Melles Griot 2051 Palomar Airport Road Carlsbad, CA 92008 Equipment List Device Manufacturer Part Number Fire Alarm Control Panel Notifier SFP-400B Photoelectric Smoke Detector Notifier SD-651 with Notifier Smoke Detector Compatibility Document Wire FPLP #18AWG Solid Atlas 1761-18-1-4J CFM Listing 7165-0028:161 7272-0028:175 7161-0972:100 Smoke Fire Dampers C & S FSDI32&FSDI30 3225-1404:105 Air Products 3230-1404:106 S O NOTIFIER® A Pittway Company FEATURES 4 Style B (Class B) Initiating Device Circuits. 2 Style Y (Class B) Notification Appliance Circuits. Complies with: NFPA 71 Central Station Signaling Systems. . NFPA 72 Local, Auxiliary, Remote Station, and Pro- prietary Signaling Systems. 24 volt model. Microprocessor-controlled. Power-limited on all circuits except Municipal Box output. Alarm and trouble resound. General Alarm operation. Supervisory input option. Waterflow input option. Alarm Verification option with discrimination between smoke detectors and contact devices. Timed silence inhibit option. Notification appliance circuit disable. Optional module for 4 zone relays (4XZM). Optional transmitter module (4XTM). Optional supervised remote annunciator (RZA-4X). Re- quires LED interface module (4XLM). Optional digital communicator (NOTI.FIRE911A). Disable/enable controls per initiating zone. Battery/earth fault supervision. Last event recall feature traps unverified alarms or intermit- tent troubles. One man Walk Test feature with zone change indication and zone trouble indication. Fuse protection on all indicating circuits. 24 VDC output power, 2.25 amperes. 7.0 AH battery, up to 60 hours standby. 230 VAC, 50 Hz international option. 4-wire smoke detector power output. Non-resettable regulated 24 VDC power outputs. Extensive transient protection. Watchdog timer to supervise microprocessor. Slide-in labels for zone identification. Steel cabinet. z • Dead-front dress panel option (DP-400B). Trim ring (TR-2-G) for flush mount between 16 center studs. SFP-400B G-1 21 4-Zone Alarm Control Panel Catalog Section: Conventional Fire Alarm Control Panels June 6, 1995 ® }1EA California ~9 State Fire 421-91-E Marshal (with gray 7165-0028:161 S635 cabinet only.) CS118 CS733 CIRCUITS Input Circuits: Initiating Device Circuit 1 (Style B) Initiating Device Circuit 2 (Style B) Initiating Device Circuit 3 (Style B) Initiating Device Circuit 4 (Style B) Output circuits (optional auxiliary relays track these cir- cuits): Notification Appliance Circuit (Style Y). Notification Appliance Circuit (Style Y). Front Panel Control Switches: Switch 1 Tone Silence. Switch 2 Alarm Silence. Switch 3 Alarm Activate (Drill). Switch 4 System Reset. (. This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 454.7161 FAX: (203) 454.7118 P1 OTI Fl £ R 12 Clintonville Road, NJorthford, Connecticut 06472 ISO-9001 Engineering and Manufacturing IJ Quality System Certified to I International Standard ISO-9001 Made in the U.S.A. I Page 1ot 2 n CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING NO. 7165-0028:161 Page 1 of 1 CATEGORY: Control Units (Non High-Rise) LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN:, Model RP1001 (preaction/deluge); Model RP1002 (release); and Models SFP400 and SFP400B (conventional). Inherently power-limited; non-coded; local, auxiliary, remote station (protected premises), proprietary (protected premises) and central station service; sprinkler supervisory and releasing device service. Refer to listee's data sheet for system detailed product description and operational considerations. System components: 4XTM Transmitter Module 4XZM Relay Module 4XLM Interface Module 4XMM Meter Module DP-4X Dress Panel 4XARB-1 Main Board 4XARB-2 Main Boards 4XARB-4 Main Board INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL': Listed as control panels for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three- pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. Proprietary protected premises unit: the system shall be interconnected with Potter Model EFT-C electrically actuated transmitter (CSFM Listing No. 7330-0328:104). Central station protected permises unit: the system shall be connected to either of the following transmitters: Firelite Model NoTI-FIRE 911/911 A series with ADEMCO Model 685 (CSFM Listing No. 7165-0078:133) control unit, or separately listed compatible control unit. *Rev. 03-04-98 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 2, 2001 Listing Expires June 30, 2002 S Authorized By: BEN HO, Supervising Deputy Program Manager November 16, 2000 DN-4924. 1-75 (I* NOTIFIER' W FIRE SYSTEMS SD-651 and CP-651 Low-Profile Conventional Detectors Section: Conventional Initiating Devices GENERAL NOTIFIER's 600 Series Plug-in Smoke Detectors offer superb performance and reliability in a profile just 1.66" (4.22 cm) deep. Model CP-651 (ionization sensor) and Model SD-651 (photoelectronic sensor) share the same sleek low-profile design and can be used with many differ- ent adapter bases in a variety of wiring configurations and voltages. Other features include low current draw, stable performance in high air velocities, built-in tamper resistant base design, remote LED option, removable cover, and built-in test switch. The 600 Series is designed to meet the performance crite- ria designated by ULJULC and EN-54. Their sensing cham- bers are sealed from back-pressure air flow, dirt, and in- sects. This chamber is protected by a fine mesh screen which can be cleaned or replaced. Additional key features include interchangeable ion and photo heads, a variety of mounting bases, and a full line of accessories. FEATURES Identical appearance to standard NOTIFIER low-profile intelligent detectors. Sleek, low-profile design. Same base for both ion and photo models. Compatible with all System Sensor 400 Series products. Two LEDs blink in standby and turn on steady in alarm. Lower standby current. Field sensitivity metering of detector to meet NFPA 72 Chapter 7 requirements. Broad range of adapter bases available. Dual LEDs provide 360° visibility. Designed to meet the requirements of UL 268. SPECIFICATIONS Operating voltage: mounting base dependent (see chart on page 2). Standby current: 100 Microamps maximum. Sensitivity: Ion: 1.9% ± 0.62%/ft.; Photo: 3% ± 0.7%/ft. Weight: 3.67 oz. (104 g). Size: 1.66".(4.22 cm) high; unflanged base 4.0 (10.16 cm) diameter; flanged base 6.2" (15.75 cm) diameter. Construction: flame-retardant thermoplastic. Operating temperature: 32°F to 120°F (0°C to 49°C). European models: Humidity range: 10% to 93% RH noncondensing. California z FM > Marshal z k State Fire Approved 7271-0028:176 LISTED SD-651: S1115 I/IEA 7272-0028:175 205-94-E SD-651 pictured in B401 Base IONIZATION All 600 Series ionization smoke detectors contain a unique single source chamber detection design which will sense the presence of smoke particles produced by fast combus- tion as well as slow smoldering fires. This chamber exhib- its increased stability, significantly reduces nuisance alarms, and provides better performance at higher air velocities. PHOTOELECTRIC All 600 Series photoelectronic smoke detectors contain a unique optical sensing chamber designed to sense the presence of smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorpo- rates signal processing to reduce false alarms. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 - _ i= N OTI Fl ER' 12 Clintonville Road, Northford, Connecticut 06472 ENCINEERINC & MANUFACT1RD .0N4-4924• 11/16100 - Page 1 of 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:175 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector IJSTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Model SD-651 photoelectric smoke detector. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's listed Models B61OLP, B612LP, B614LP, B616LP bases (CSFM Listing No. 7300-0028:173) or System Sensor's Model B401 base (CSFM Listing No. 7300-1209:128) and separately listed compatible control units. XLF: 7272-1209:159 11-10-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test I results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 41 2001 Listing Expires June 30, 2002 Authorized By: BEIVHO, Supervising Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:173 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories USTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Models BX501, B61OLP, B612LP, 136140, B616LP and B71OLP detector bases. Refer to listees data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product designation, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. WLF: 73001209:128 07-29-94 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test f results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 4, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager N OT I F I E R® Device Compatibility Document I Document 15378 RevX ECN01-084 I Detector Model Base Model SGL-2000 SGL-404 SFP-1 024 System Sensor 1100/D N/A 20 N/A 24 20 System Sensor 2100/D/S N/A 20 N/A 24 20 System Sensor 2100T/D/S N/A 20 N/A 24 20 System Sensor DI-IlOOP N/A 20 N/A 20 20 Note 1: System Sensor & Fenwal Detectors can be mixed or matched in any zone, provided maximum detector standby current per loop is not exceeded. Note 2: When using two-wire smoke detectors containing supplementary relays or indicators, the operation of more than one detector per zone cannot be ensured. Note 3: A suffix "A" must be placed at the end of System Sensor part number when purchasing detectors for Canadian Applications. RP-1001 SSOO Detector Model Base Model 11P-1002 ( 0B PAR-3 XPM-8 S5000 SFF-400 (Notifier CP-65' B401/B6IOLP/B6I6LP 15/15/1 15/15/1 N/A 20/20/1 30/30/1 Notifier SD-651 B401/B6IOLP/B6I6LP 15/15/1 15/15/1 N/A 20/20/1 30/30/1 70-201000-001 70-201000-002 Fenwal FSD-7125 20 20 25 25 51 70-201000-003 70-201000-005 70-201000-001 Fenwal PSD-7126 70-201000-002 20 20 25 25 51 70-201000-003 70-201000-005 70-201000-001 70-201000-002 Fenwal CPD-7021 60 30 30 41 60 70-201000-003 70-201000-005 Fenwal PSD-7129 70-211002-000 100 1 1 1 N/A Fenwal CPD-7021 70-211002-000 60 1 1 1 1 HS-22D I-1S-2-RB Hochiki SIH-24F YBA-M22 40 30 30 35 60 HSB-220 HSB-224 0 Document 15378 RO 2/28/2001 28 of 31 0 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING APPROVAL: 7161-0972:100 Page 1 of 1 Cables-Fire Protective Signaling Atlas Wire & Cable, 133 S. Van Norman Rd., Montebello CA 90640 Contact: Tony Sanders (213) 723-2401 Model FPL, FLPR and FPLP power limited fire protective signaling cables. Conductors: Two or more conductors Insulation: Solid SRPVC, North America Plastics, Grade 'NORPLAS" 21570 and/or Gitto/Global Corp, garde GA-8705-03P, Synergistics, Grade 1360-1021-PID. Shield: Polyester film bonded to a aluminum foil; serving, wrap or braid of aluminum wire or of metal-coated or uncoated copper wire (optional). Jacket: PVC, North American Plastics, Grade "NORPLAS" 882A or Gitto/Global Corp., Grade GA-8705-03, or Senergistics, Grade 1690-1060 PJD. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listee's name, Type "FPL", "FPLR", "FPLP", and UL label. Listed as power-limited fire protective signaling cables. Rev. 04-29-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 30, 2001 Listing Expires June 30, 2002 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 3225-1404:105 Page 1 of 1 CATEGORY: Fire Dampers LISTEE: C & S Air Products, 2824 N. Sylvania Ave., Fort Worth, TX 76111 Contact: Michael Beaver (817) 831-7038 DESIGN: Models FD-120, FSD-121, FSD-122, FSD-123, FSD-131, FSD-132; FD-320, FSD-321, FSD-322 and FSD-323 single and multi blade type construction fire dampers with No. 16 or No. 20 galvanized or stainless steel frame and No. 16 galvanized or stainless steel blades. Refer to listee's data sheet for detailed product description and operational considerations. Sizes of dampers are as follow: Construction Width, Inch Height, Inch Mm. Max. Mm. Max. Single section 6 36 6 48 Multiple section 16 108 8 96 FSD-131, -132 8 24 8 24 (single only) RATING: FSD-131, FSD-132: 1-1/2 hour, 1 hour (Corridor) FD-120, FSD-121, -122, -123: 1-1/2 hour FD-320, FSD-321, -322, -323: 3 hour INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, classification/rating and UL label. APPROVAL: Listed as 1 -hour, 1-1/2-hour and 3-hour fire-rated dampers. *Intended for use with approved damper operators. For vertical or horizontal installations. NOTE: Leakage rating not evaluated. Refer to CSFM Listing No. 3230-1404:106 for leakage dampers. XLF: 3225-0368:110 *Rev. 11-06-2001 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: NOVEMBER 6, 2001 Listing Expires June 30, 2002 Authorized By: DIANE K. A REND, Senior Deputy 0 Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 3230-1404:106 Page 1 of 1 CATEGORY: Leakage Dampers LISTEE: C & S Air Products, 2824 N. Sylvania Ave., Fort Worth, TX 76111 Contact: Michael Beaver (817) 831-7038 DESIGN: Model FSD-121, -122, -123, -131, -132; SD-121, -122, -123; and FSD-321, -322, -323, single and multi blade type construction leakage dampers with No. 16 or No. 20 galvanized or stainless steel frame and No. 16 galvanized or stainless steel blades. Refer to listee's data sheet for detailed product description and operational considerations. Sizes of dampers are as follow: Construction Width, Inch Mm. Max. Single section 6 36 Multiple section 16 108 FSD-131, -132 8 24 (Single only) FSD-121, -321, -131: Class I FSD-122, -322, -132: Class II FSD-123, -323: Height, Inch Mm. Max. 6 46 8 92 8 24 Class III INSTALLATION MARKING: APPROVAL: XLF: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, classification and UL label. Listed as Class I, II or Ill leakage-rated dampers. *Intended for use with approved damper operators. For vertical or horizontal installations. 3230-0368:111 *Rev. 09-11-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: SEPTEMBER 11, 2001 Listing Expires June 30, 2002 Authorized By: DIANE K. A REND, Senior Deputy Program Manager