HomeMy WebLinkAbout7819 RUSH ROSE DR; ; AS060271; Permit6/13/22, 4:59 PM AS060271 Permit Data City of Carlsbad Sprinkler Permit 7819 RUSH ROSE Job Address: DR Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Permit No: AS060271 Status: ISSUED Applied 11/14/2006 Approved: 11/14/2006 Issued: 11/14/2006 PC #: Inspector: Project Title: LA COSTA GLEN RECREATION FIRE SPRINKLER SYSTEM INSPECTINS @ $62/HR Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 372 0 372 0 1/1 LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 06-9997 ' FAX (760) 806-4813 Hydraulic Design Information Sheet II I I L11 High Roof Calculation Name: LA COSTA GLEN Date: August 4, 2006 Location: 7819 RUSH ROSE DR., 92008 Building: RECREATION System No. HIGH ROOF Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. FP3 Construction: Z Combustible 0 Non-COmbustible Ceiling Height <10-0 Ft. SYSTEM DESIGN NFPA 13: 0 Light Hazard Ordinary Hazard Group El 1 El 2 El 3 El Extra Hazard El NFPA 231 0 NFPA 23 1C: Figure: Curve: fl Other (Specify) El Specific Ruling Made By Date Area of Sprinkler Operation 900 System Type Density .10 Z Wet El Dry El Deluge El Pre-Action Area Per Sprinkler 225 SQ. FT. MAX. Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make RASCO Model GFR Hose Allowance GPM: Outside 100 Size 1/2 K-Factor: 5.6 Rack Sprinkler Allowance N/A Temperature Rating 165 DEG. CALCULATION SUMMARY GPM Required 243.94 PSI Required 102.52 At Base of Riser "C" Factor Used: Overhead 120 Underground 150 WATER SIJPPI.Y Water Flow Test Pump Data Tank or Reservoir Date & Time 5-11-06 /10:30 AM Rated Capacity Capacity Static PSI 150 At PSI Elevation Residual PSI 135 Elevation GPM Flowing 1330 Well Elevation 0 Proof Flow GPM Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack - Rack El Single Row El Conventional Pallet El Double Row El Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal Transverse - Horizontal Barriers Provided El Automatic Storage El Encapsulated El Solid Shelving El Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. LA COSTA GLEN RECREATION BLDG HIGH ROOF .10/900 Sigma Dynamics Corporation 7700 Supply / Demand Graph 240 Margin - - ____ ____ _____ _____ ______ ______ _______ _______ J Pressure 61.29 PSI Flow 2761.44 GPM - 1 210 200 190 180 -- - - - 17a 160 150 140 130 120 iio 100 90 ----- 80-- o '• _____ _____ ______ ______ 70 _______ _______ ________ ________ 60 50 .t ow C 30 10 150 300 1111111111 450 600 __ __ __ 750 900 ___ ___ 1050 ___ ___ 1200 ___ ____ ____ N1 1350 15 Water Flow (GPM) System Demand Sprinkler Demand Additional Flows Hose at Source Total Demand 73.02 PSI 73.02 PSI 167.49 GPM 0.00 GPM 100.00 GPM 267.49 GPM Water Supply.. Static 135.00 PSI Residual 121.50 PSI Elevation 0.00 PSI 1330.00 GPM SUBMITTAL SERIAL NO:4144HY1 08-03-2006 PAGE 1 LA COSTA GLEN RECREATION BLDG HIGH ROOF .10/900 AREA REDUCED PER NFPA 13, 1999 SEC 7-2.3.2.4 <10-0 CEILING FLOW TEST RESULTS Water Supply STATIC 135.00 PSI RESIDUAL 121.50 PSI @ 1330.00 GPM CITY PRESSURE AVAILABLE AT 267.5 GPM 134.31 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 200 20.18 14.82 5.60 12.98 201 1.36 14.82 5.60 11.96 202 17.82 14.82 5.60 10.13 203 17.09 14.82 5.60 9.32 204 16.37 14.82 5.60 8.55 205 15.70 14.82 5.60 7.86 206 15.66 14.82 5.60 7.82 207 15.01 14.82 5.60 7.19 208 15.46 14.82 5.60 7.63 209 14.82 14.82 5.60 7.00 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 30 TO 40 167.49 GPM 100.00 GPM 267.49 GPM 73.02 PSI 0.00 PSI 22.91 FPS SUBMITTAL SERIAL NO:4144HY1 08-03-2006 PAGE 2 LA COSTA GLEN RECREATION BLDG HIGH ROOF .10/900 AREA REDUCED PER NFPA 13, 1999 SEC 7-2.3.2.4 <10-0 CEILING Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 207 209 1.380 L 9.33 C=120 PT 7.00 (209) Q 14.82 -.0 F 0.00 P8 0.00 BN T 9.33 0.0197 PF 0.18 205 207DQ 15.01 1.380 L 9.33 C=120 PT 7.18 (207) Q 29.83 F=0 F 0.00 PE 0.00 BN T 9.33 0.0717 PF 0.67 203 205DQ 15.70 1.380 L 9.33 C=120 PT 7.85 (205) Q 45.53 F=0 F 0.00 PE 0.00 BN T 9.33 0.1568 PF 1.46 201 203DQ 17.09 1.380 L 9.33 C=120 PT 9.31 (203) Q 62.62 F=0 F 0.00 PE 0.00 BN T 9.33 0.2828 PF 2.64 61 201DQ 19.36 1.380 L 8.17 C=120 PT 11.95 (201) Q 81.99 F=T F 6.00 PE 0.00 BN T 14.17 0.4654 PF 6.59 ------------------ PT 18.54 ( 61) 206 208 1.380 L 9.33 C=120 PT 7.63 (208) Q 15.46 F=0 F 0.00 PE 0.00 BN T 9.33 0.0213 PF 0.20 204 206DQ 15.66 1.380 L 9.33 C=120 PT 7.83 (206) Q 31.13 F=0 F 0.00 PE 0.00 BN T 9.33 0.0776 PF 0.72 202 204DQ 16.37 1.380 L 9.33 C=120 PT 8.55 (204) Q 47.50 F=0 F 0.00 PE 0.00 BN T 9.33 0.1696 PF 1.58 200 202DQ 17.82 1.380 L 9.33 C=120 PT 10.13 (202) Q 65.32 F=0 F 0.00 PE 0.00 EN T 9.33 0.3057 PF 2.85 60 200DQ 20.18 1.380 L 8.17 C=120 PT 12.98 (200) Q 85.50 F=T F 6.00 PE 0.00 EN T 14.17 0.5030 PF 7.13 ------------------ PT 20.11 ( 60) 60 61 1.728 L 10.00 C=120 PT 18.55 ( 61) Q 81.99 F=0 F 0.00 PE 0.00 FM5 T 10.00 0.1557 PF 1.56 SUBMITTAL SERIAL NO:4144HY1 08-03-2006 PAGE 3 LA COSTA GLEN RECREATION BLDG HIGH ROOF .10/900 AREA REDUCED PER NFPA 13, 1999 SEC 7-2.3.2.4 <10-0 CEILING Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 40 60DQ 85.50 1.728 L 10.25 C=120 PT 20.11 ( 60) Q 167.49 F=T F 9.00 PE 0.00 FM5 T 19.25 0.5837 PF 11.24 30 40 1.728 L 7.67 C=120 PT 31.35 ( 40) Q 167.49 F=T,E F 12.70 PE 1.30 FM4 T 20.37 0.5837 PF 11.89 6 30 2.203 L 11.67 C=120 PT 44.54 ( 30) Q 167.49 F=T F 11.60 PE 0.00 FM2 T 23.27 0.1789 PF 4.16 5 6 2.203 L 19.50 C=120 PT 48.70 ( 6) 0 167.49 F=2T,E,EE F 30.45 PE 0.00 FM1 T 49.95 0.1789 PF 8.94 3 5 2.703 L 24.00 C=120 PT 57.64 ( 5) Q 167.49 F=2E F 13.20 PE 9.32 FR T 37.20 0.0661 PF 2.46 2 3 6.357 L 10.00 C=120 PT 69.42 ( 3) Q 167.49 F=E F 12.57 PE 0.00 UN T 22.57 0.0010 PF 0.02 1 2 5.914 L 49.00 C=150 PT 69.44 ( 2) O 167.49 F=2EE,GV F 26.18 PE 0.00 UN T 75.18 0.0010 PF 0.08 0 1 5.914 L 46.00 C=150 PT 69.52 ( 1) Q 167.49F=T,V,EE/3E,T,DCA F 172.55 PE 0.00 UN T 218.55 0.0010 PF 0.22 6" DOUBLE CHECK DETECTOR ASSEMBLY 3.31 PT 73.05 ( 0) O Automatic Storage O Solid Shelving 0 Encapsulated U Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 n L L I Hydraulic Design Infonnation Sheet FI LE Level 1 Calculation Name: LA COSTA GLEN Date: August 4, 2006 Location: 7819 RUSH ROSE DR., 92008 Building: RECREATION System No. LEVEL 1 Contractor: LIFEGUARD FIRE PROTECTION, INC. Contract No. Calculated By: LCH Drawing No. FP3 Construction: Z Combustible 0 Non-Combustible Ceiling Height 20-0 Ft. SYSTEM DESIGN NFPA 13: 0 NFPA 231 O Other (Specify) []Specific Ruling Light Hazard Ordinary Hazard Group 0 1 0 2 [1 3 fl Extra Hazard 0 NFPA 23 IC: Figure: Curve: Made By Date Area of Sprinkler Operation 1125 System Type -- Density .10 Z Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 225 SQ. FT. MAX. Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make RASCO Model G4A Hose Allowance GPM: Outside 100 Size 1/2 K-Factor: 5.6 Rack Sprinkler Allowance N/A Temperature Rating 165 DEG. CALCULATION SUMMARY GPM Required 243.94 PSI Required 102.52 At Base of Riser "C" Factor Used: Overhead 120 Underground 150 "I A 5II!U ILIVA Water Flow Test Pump Data Tank or Reservoir Date & Time 5-11-06/10:30 AM Rated Capacity Capacity Static PSI 150 At PSI Elevation Residual PSI 135 Elevation GPM Flowing 1330 Well Elevation 0 Proof Flow GPM' Location SITE Source of Information LIFEGUARD FIRE WITH CARLSBAD FIRE WMMU011Y S1OKAUE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Pàlletized % Rack - Rack EiJ Single Row El Conventional Pallet O Double Row fl Slave Pallet O Multiple Row 0 Open Flue Spacing In Inches Longitudinal Transverse Horizontal Barriers Provided 2 2 2 LA COSTA GLEN RECREATION BLDG .1011125 Sigma Dynamics Corporation 7700 Suoolv I Demand GraDh 40 30 20 -i Margin Pressure 27.87 PSI Flow 1665.07 GPM - - - ----- - - J 1c - ____ ____ _____ _____ ______ ______ ______ _______ - - - - - _____ _____ ______ ______ 0c _______ _______ ________ ________ _________ 90 80 70 60 50 40--- 30, - - - - - 20---- 10 00::1 - - 80 70 60--------- 50 I-I 40----------- 20------------ 30)—__---_—______________ 10 IjIiiiiiiiiii 150 300 450 600 750 900 1050 1200 15O Water Flow GPM) System Demand.. Sprinkler Demand 106.02 PSI @ 243.94 GPM Additional Flows 0.00 GPM Hose at Source 100.00 GPM Total Demand 106.02 PSI @ 343.94 GPM Water Supply.. Static 135.00 PSI Residual 121.50 PSI @ 1330.00 GPM Elevation 0.00 PSI SUBMITTAL SERIAL NO:4144HY1 08-02-2006 PAGE 1 LA COSTA GLEN RECREATION BLDG .10/1125 AREA REDUCED PER NFPA 13, 1999 SEC. 7-2.3.2.4 20-0 CEILING FLOW TEST RESULTS Water Supply STATIC 135.00 PSI RESIDUAL 121.50 PSI @ 1330.00 GPM CITY PRESSURE AVAILABLE AT 343.9 GPM SUMMARY OF SPRINKLER OUTFLOWS 133.89 PSI ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 100 29.60 18.00 5.60 27.94 101 24.96 18.00 5.60 19.87 102 24.24 18.00 5.60 18.73 103 23.89 18.00 5.60 18.20 104 23.79 18.00 5.60 18.04 105 21.77 18.00 5.60 15.11 106 19.78 18.00 5.60 12.47 107 18.38 18.00 5.60 10.77 108 18.00 18.00 5.60 10.33 109 18.16 18.00 5.60 10.51 110 21.37 18.00 5.60 14.57 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 5 TO 6 243.94 GPM 100.00 GPM 343.94 GPM 106.02 PSI 0.00 PSI 20.53 FPS SUBMITTAL SERIAL NO:4144HY1 08-02-2006 PAGE 2 LA COSTA GLEN RECREATION BLDG .10/1125 AREA REDUCED PER NFPA 13, 1999 SEC. 7-2.3.2.4 20-0 CEILING Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN D ice Ft PSI/Ft PSI 58 108 1.080 L 8.75 C=120 PT 10.33 Q 18.00 =T,E F 8.10 PE -0.94 DR T 16.85 0.0929 PF 1.57 PT 10.96 ( 58) ------------------ 55 110 1.080 L 7.17 C=120 PT 14.57 Q 21.37 F=T,E F 8.10 PE -0.94 DR T 15.27 0.1277 PF 1.95 PT 15.58 ( 55) --------------- 59 109 1.080 L 3.67 C=120 PT 10.51 Q 18.16 F=T,2E F 10.40 PE -0.94 DR T 14.07 0.0944 PF 1.33 58 59 1.728 L 5.75 C=120 PT 10.90 ( 59) Q 18.16 F=0 F 0.00 PE 0.00 BN T 5.75 0.0096 PF 0.06 57 58DQ 18.00 1.728 L 6.75 C=120 PT 10.96 ( 58) Q 36.16 F=0 F 0.00 PE 0.00 BN T 6.75 0.0342 PF 0.23 PT 11.19 ( 57) ------------------ 57 107 1.080 L 3.67 C=120 PT 10.77 (107) Q 18.38 F=T,2E F 10.40 PE -0.94 DR T 14.07 0.0966 PF 1.36 13.33 C=120 PT 11.19 ( 57) 7.40 PE 0.00 20.73 0.0732 PF 1.52 PT 12.71 ( 56) 2.50 C=120 PT 12.47 (106) 8.10 PE -0.94 10.60 0.1106 PF 1.17 11.00 C=120 PT 12.70 ( 56) 11.10 PE 0.00 22.10 0.1298 PF 2.87 PT 15.57 ( 55) 2.50 C=120 PT 15.11 (105) 8.10 PE -0.94 10.60 0.1321 PF 1.40 L 26.17 C=120 PT 15.57 ( 55) F=T F 9.00 PE 0.00 T 35.17 0.3028 PF 10.65 PT 26.22 ( 20) 56 57DQ 36.16 1.728 Q 54.54 BN ------------------ 56 106 1.080 Q 19.78 DR 55 56DQ 54.54 1.728 Q 74.31 BN 55 105 ." i 1.080 Q 21.77 DR 20 550Q 95.69 1.728 Q 117.46 BN L F=2E F T L F=T, E F T L F=3E F T L F=T, E F T SUBMITTAL SERIAL NO:414411Y1 08-02-2006 PAGE 3 LA COSTA GLEN RECREATION BLDG .10/1125 AREA REDUCED PER NFPA 13, 1999 SEC. 7-2.3.2.4 20-0 CEILING Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 54 ------------------ 104 1.080 L 7.58 C=120 PT 18.04 (104) Q 23.79 F=T,E F 8.10 PE -2.92 DR T 15.68 0.1556 PF 2.44 53 54 1.728 L 11.00 C=120 PT 17.56 ( 54) Q 23.79 F=0 F 0.00 PE 0.00 EN T 11.00 0.0158 PF 0.17 PT 17.73 ( 53) 53 ------------------ 103 1.080 L 7.58 C=120 PT 18.20 (103) Q 23.89 F=T,E F 8.10 PE -2.92 DR T 15.68 0.1569 PF 2.46 52 53DQ 23.79 1.728 L 10.50 C=120 PT 17.74 ( 53) Q 47.68 F=0 F 040 PE 0.00 BN T 10.50 0.0571 PF 0.60 PT 18.34 ( 52) 52 ------------------ 102 1.080 L 7.58 C=120 PT 18.73 (102) Q 24.24 F=T,E F 8.10 PE -2.92 DR T 15.68 0.1611 PF 2.53 51 52DQ 47.68 1.728 L 10.50 C=120 PT 18.34 ( 52) Q 71.91 F=0 F 0.00 PE 0.00 BN T 10.50 0.1222 PF 1.28 PT 19.62 ( 51) 51 ------------------ 101 1.080 L 7.58 C=120 PT 19.87 (101) Q 24.96 F=T,E F 8.10 PE -2.92 DR T 15.68 0.1702 PF 2.67 19 51DQ 71.91 1.728 L 5.17 C=120 PT 19.62 ( 51) Q 96.88 F=T F 9.00 PE 0.00 BN T 14.17 0.2120 PF 3.00 9 19 1.728 L 4.58 C=120 PT 22.62 ( 19) Q 96.88 F=T F 9.00 PE 1.98 NR T 13.58 0.2120 PF 2.88 PT 27.48 ( 9) 50 ------------------ 100 1.080 L 7.58 C=120 PT 27.94 (100) Q 29.60 F=T,E F 8.10 PE -2.92 DR T 15.68 0.2332 PF 3.66 18 50 1.728 L 5.17 C=120 PT 28.68 ( 50) Q 29.60 F=T F 9.00 PE 0.00 BN T 14.17 0.0236 PF 0.33 SUBMITTAL SERIAL NO:4144HY1 08-02-2006 PAGE 4 LA COSTA GLEN RECREATION BLDG .10/1125 AREA REDUCED PER NFPA 13, 1999 SEC. 7-2.3.2.4 20-0 CEILING Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 18 1.728 L 4.58 C=120 PT 29.01 ( 18) Q 29.60 F=T F 9.00 PE 1.98 NR T 13.58 0.0236 PF 0.32 PT 31.31 ( 8) 9 ------------------ 20 2.203 L 13.58 C=120 PT 26.22 ( 20) Q 117.46 F=0 F 0.00 PE 0.00 FM3 T 13.58 0.0928 PF 1.26 8 9DQ 96.88 2.203 L 13.58 C=120 PT 27.48 ( 9) Q 214.33 F=O F 0.00 PE 0.00 FM3 T 13.58 0.2823 PF 3.83 7 8DQ 29.60 2.203 L 12.17 Cr120 PT 31.31 ( 8) Q 243.94 F=T F 11.60 PE 0.00 FM3 T 23.77 0.3586 PF 8.52 6 7 2.203 L 58.33 C=120 PT 39.83 ( 7) Q 243.94 F=T,3E F 26.00 PE 0.29 FM2 T 84.33 0.3586 PF 30.24 5 6 2.203 L 19.50 C=120 PT 70.36 ( 6) Q 243.94 F=T,E,EE F 30.45 PE 0.00 FM]. T 49.95 0.3586 PF 17.91 3 5 2.703 L 24.00 C=120 PT 88.27 ( 5) Q 243.94 F=2E F 13.20 PE 9.32 FR T 37.20 0.1324 PF 4.93 2 3 6.357 L 10.00 (~R PE PT 102.52 ( 3) Q 243.94 F=E F 12.57 0.00 UN T 2.57 0.0021 PF 0.05 1 2 5.914 L 49.00 C=150 PT 102.57 ( 2) Q 243.94 F=2EE,GV F 26.18 PE 0.00 UN T 75.18 0.0019 PF 0.14 0 1 5.914 L 46.00 C=150 PT 102.71 ( 1) Q 243.94F=T,GV,EE/3E,T,DCA F 172.55 PE 0.00 UN T 218.55 0.0019 PF 6" DOUBLE CHECK DETECTOR ASSEMB 2 .88 PT 106.01 ( 0) Lifeguard ñre Protection Inc. 2605 Temple /le/q/1t5 Drive, 5te. r Ocean5ldel CA 9256 P ('760) 506-9997 F (760) 506-45 / 3 F1- r, -1 :p APPROVED B1ilTTED CARLSBAb%tRTMENT La Co.5te? 6/en - Pha-5e 4 FIre Protection Material 5ubmlttRl 5prink/er.s REVIEWED APPROVED_________________________ APPROVED AS NOTED_______________ NOT APPROVED. RESUBMIT___________ This checking and approval covers coordination of work, field dimensions, and layout. Conformance with design concept not checked. Weitz Company approval does not relieve Supplier of contractual obligations. SPECIFICATION REFERENCE I I 5 THE WEITZ COMPANY GENERAL CONTRACTORS By_fti) Date S !c)1/O 7 Checking is only for general confirmation with the design Concept of the Project and general compliance with the information given In the Performance SpecificatioflL TSUCHIYAMA KAINO SUN & CARTER CONSULTING MECHANICAL ENGINEERS Upright Conventional T 0 TI P - .---Ed 'I Pendent Intermediate Level Pendent Small Orifice Upright intermeatate Level Upright Bulletin 131 Rev. I liable Model GFR Model GFR Recessed Quick Response Sprinklers UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNlV Product Description Reliable Models GFR and GFR Recessed Sprinklers are Quick Response fusible solder type automatic sprinklers. These sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables the Models GFR and GFR Recessed Sprinklers to apply water to a fire much faster than standard response sprinklers of the same temperature rating. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, de- flector style and sprinkler spacing are in accordance with the latest published standards of the National Fire Protec- tion Association or the approving Authority Having Juris- diction. Quick response sprinklers are intended for standard area coverage and standard water densities as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. Model GFR Sprinkler Types Standard Upright Standard Pendent Horizontal Sidewall HSW1 Deflector Intermediate Level Upright Intermediate Level Pendent Conventional Model GFR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall HSW1 Deflector Approvals Underwriters Laboratories, Inc. (UL) Underwriters' Laboratories of Canada (ULC) NYC BS&A No. 587-75-SA MIL-S-901C and MIL-STD-167-1 NYC MEA 258-93-E Horizontal Sidewall Recessed Recessed Pendent HSW 1 Deflector Horizontal Sidewall HSW 1 Deflector The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 3-7/16" [87.3mm] 2-7/8 [73.0mm] Sprinkler Assembly Sprinkler Assembly Model GFR Quick Response Upright, Pendent & Conventional Sprinklers Upright Pendent Conventional Small Orifice Upright Installation Wrench: Model D Sprinkler Wrench Installation Data Sprinkler Type Nominal K Factor Sprinkler Height Approvals Sprinkler Identification Number (SIN) US Metric SSU SSP Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.6 4.2 2.8 4.2 8.0 (T1 mm) 80 60 40 60 115 2%" (73mm) 2%" (73mm) 2%" (73mm) 73mm 21 e"(75mm) 12,36,7 1,2,3,7 12,3,7 1,2,3,7 R3125 R3115 1/? (15mm) Standard Orifice with Y2" NPT (R½) Thread Ij " (11mm) Small Orifice with ½" NPT (R½) Thread %" (10mm) Small Orifice with ½" NPT (RI/2) Thread (10mm) 10mm Orifice XLH with R% Thread l%2 (20mm) Large Orifice with 34" NPT (R34) Thread R3123 R3113 R3121 R3111 R3124 IR3114 R3127 R3117 Conventional-Install in Upright or Pendent Position 4.2 5.6 60 80 73mm 73mm R3174 R3175 10mm Orifice XLH with R% Thread 15mm Standard Orifice with ½" NPT (R1/2) Thread Model GFR Quick ResDonse UDriaht & Pendent Intermediate Level SDrinklers 4-1/2" Dia. (174.3mm) I Locknut Spring la be Maee,bled OS lnstO(lchon 4-7/2" Did. [114.3mm] - ro Be Assembled Al l(,stolfation I - Shield S 7371kW-B IJIINTP-B Upright Installation Wrench: Model 0 Sprinkler Wrench Installation Data Pendent Sprinkler Type Nomine' K Factor Sprinkler Height Approvals Sprinkler Identification Number (SIN) US I Metric SSU SSP Standard Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.6 8.0 80 115 2%" (73mm) 2/" (75mm) 1,2,3,7 1,2,3,7 R3195 R3115 ½" (15mm) Standard Orifice with ½" NPT (R½) Thread IY32' (20mm) Large Orifice with 34" NPT (R3/4) Thread R3197 R3117 NOTE—The protective shield must be assembled in the field per the assembly drawings. 2. Model GFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW1 Installation Wrench: Model D Sprinkler Wrench Installation Data Nominal Nominal K Factor Sprinkler Approval Organization and Type of Approval Sprinkler ident. Number Light Ordinary Orifice Thread Size US Metric Height Hazard Hazard (SIN) '/?(l5mm) Y2' NPT (R½) 5.6 80 3%'(84mm) 1,2,3,7 '1,2,3,7 R3135 <6'(11mm) V? NPT (R½) 4.2 60 3%6 (84mm) 1,2,3,7 - R3133 %'(lornm) W NPT (R½) 2.8 41 3Ae'(84mm) 1,2,3,7 - R3131 %'(0i) 3% NPT (R½) 8.2 119 3y6'(84mm) 1,2,3,7 - R3137 Model GFR Quick Response Recessed Pendent Sprinklers low Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data Sprinkler Type Nominal K façtor Sprinkier height Approvals Sprinkler Identification Number (SIN) US Metric Ile (l5nim) Standard Orifice 5.6 80 2%' (73mm) 1,2,3,7 R3115 with W NPT (R½)lliread 6 (11 mm) Small Orifice with 4.2 60 2%' (73mm) 1,2,3,7 R3113 W NPT (R½) Thread %(1Orrn) Small Orifice with 2.8 40 2% (73mm) 1,2,3,7 R3111 W NFl (F) Thread 10Tn1 Orifice XLH with R3 4.2 60 (73mm) - R3174 Thread 'y'(20rrTn) Large Ortflce 8.0 115 21yj;(75mm) 1,2,3,7 R3117 with 3/4' NFl (R3/4) Thread 2 1/4 [57. lnn,] O,a. H.I. or. in C,&n I I5/I6 01,. Spri5g Colic,' r (49.2nn,] UnIS liglIl Agoi,ol Sp'inkInr W,nflch 80nn "\\\ 1 Adjeol i Refer to escutcheon data table for specific escutcheon approvals and dimensions $JI800P-8 0t, Model GFR Quick Response Recessed Horizontal Sidewall Sprinklers Deflector: HSW1 Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data Nominal Thread Size Nominal K Factor Sprinkler Approval Organization' Type of Approval Sprinkler Identification Light Ordinary Number Orifice NPT US Metric Height Hazard Hazard (SIN) 1/2' (15mm) 1/2"(R1/2) 5.6 81.0 3Y18' (84mm) 1,2,3,7 1,2,3,7 R3135 '(11mm) YS'(RV2) 4.2 61.0 35/6"(84mm) 1,2,3,7 - R3133 %'(lomm) 1/2'(R 1/2) 2.8 40.6 31o'(84mm) 1,2,3,7 - R3131 '5/'(20mm) 3/4'(R 1/2) 8.0 118.2 35/io'(84mm) 1,2,3,7 - R3137 Refer to escutcheon data table for specific escutcheon approvals and dimensions. 3. (1016mmn W 152.4-1 T,,n SOm0g Comm 1 1511 6 ' 0K L -L J (57.2mm) - (2) .ndjo,lme,,I 1-8 Model GFR & GFR Recessed Quick Response Sprinklers Installation Quick response sprinklers are intended for standard area coverage and standard water densities as specified in NFPA-13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. The Model GFR Recessed Quick Response Sprinkler is to be installed as shown. The Model Fl or F2 Escutcheons il- lustrated are the only recessed escutcheons to be used with the Model CR Pendent or Horizontal Sidewall Sprin- klers. The use of any other recessed escutcheon will void all approvals as a quick response sprinkler and negate all warranties. When installing Model GFR Sprinklers, use the Model D Sprinkler Wrench and when installing Model GFR Re- cessed Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may cause sprinkler damage. Maintenance The Models GFR and GFR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean the sprinklers with soap and water, ammonia or any other cleaning fluids. Re- move any dust using a soft brush or gene vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in anyway. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installa- tion, sprinklers should be maintained in the original cartons and packaging until used. This minimizes the potential for damage resulting in improper operation or non-operation. Ordering Information: Specify Sprinkler model Sprinkler type Orifice size Temperature rating Sprinkler finish Escutcheon type Escutcheon finish (where applicable) Note: When Recessed Model GFR/F1 or F2 are ordered, sprinkler and escutcheon are packaged separately. Sprinkler Types Standard Upright Standard Pendent Sidewall - Horizontal HSW1 Deflector Conventional Recessed - Pendent - Horizontal Sidewall HSW 1 Deflector Intermediate Level - Upright - Pendent Finishe&l1121 Standard Finishes Sprinkler Escutcheon Bronze Chrome Plated Brass Chrome Plated Special Application Finishes Sprinkler Escutcheon Bright Brass Black Plated Satin Chrome Bright Brass Chrome Plated Satin Chrome Other finishes and colors are available, consult factory for details a All sprinklers have black painted solder links Temperature Ratings Classification Sprinkler Rating Maximum Ambient Temperature Ordinary 165 74 100 38 Intermediate 212 100 150 66 Escutcheon Data Escutcheon Approvals Adjustment Face of Fitting To Ceiling or Model Wall Dimension Fl 1,2,3 12,3, y" (19mm) )" (13mm) / (mm4mm) F2 rnm?8mm) The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and properly for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled ' Paper (800) 431-1588 Sales Offices Relisibid (800) 848-6051 Sates Fax Revision lines indicate updated or new data (914)668-3470 Corporate Offices w.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 7/05 P/N9999970024 Bulletin 154 Rev.E b ee The Concealer® UL Quick Response FM Standard Response Concealed Sprinkler With a 1/2" (13mm) or 11/211 (38mm) Adjustment Features Cover plate attachment with )2" (13mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in brass, chrome or black plated and white painted finishes. Ordinary temperature rating. Multiple orifices for design flexibility. Approvals & Listings Underwriters Labortories, Inc. (UL)- Quick Response Underwriters Laboratories of Canada (ULC)- Quick Response Factory Mutual Research Corp. (FM)- Standard Response Light Hazard Occupanicies- No Limitations Ordinary Hazard Occupancies Groups 1 & 2 Wet Systems Only 4. NYC MEA 258-93-E - Quick Response U.S Patent number 4,880,063. Application The Reliable Model G4A Concealero is the most versatile quick response concealed sprin- kler available. It provides the best form of fire protection while offering an attractive appearance and /2" (13mm) of cover adjust- ment for ease of installation. The small diameter cover plate as- sembly is easily attached and blends into the ceiling, concealing the most dependable fire protec- tion available, an automatic sprinkler system. Model G4A Quick Response Concealed Automatic Sprinkler The Model G4A Concealers is designed for use where aesthetic appearance is important. Offices, hospitals, motels and restaurants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the designer to optimize system performance, thereby achieving a very efficient installation. The Model G4A Concealers is a UL Listed Quick Response Concealed sprinkler intended for use in accordance with NFPA 13. FM Approves this sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2-8N. Product Description The Reliable Model G4A Concealero uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides ½" (13mm) of cover adjustment The flat cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus exposing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552 Model G4 Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Installation Do not install the G4A Concealere in ceilings which have positive pressure in the space above. Cut a 2% inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model G4 Wrench. The wrench has drive tangs which insert into the cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench tangs engage the drive slots in the top of the cup (there are two sets of drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinklerfcup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re-install cap until the cover plate is installed. Maintenance The Model G4A Concealers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Technical Data Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Assembly Finish Inlet Type Cover Plate FinishesW Standard Finishes Bronze Chrome White Paint Special Application Finishes Bright Brass Bladk Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. TemDerature Ratina Classification Sprinkler Cover I Plate Max. Ambient Temp. Ordinary 165°F/74°C 1350F/571C 100°F/38°c Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor Thread Approvals Sprinkler Identification (SIN) US Metric Non Adjustable ½" (13mm) 1/2"(15mm) 5.6 80 ½" NPT (R½) 1,2,3,4 R5415 Non Adjustable 1/2 (13mm) 7/,," (1 1mm) 4.2 60 ½ "NPT (R1/2) 1,2,4 R5413 Non Adjustable ½" (13mm) YZ (10mm) 2.8 40 1/2 "NPT (R½) 1,2,3,4 1 R5411 Adjustable I 1 '/2" (38mm) L2!(15mm) 5.6 80 1" NPT Male or Female 1,2,4 R5418 Adjustable 11/2" (38mm) 341101 mm) 4.2 60 1" NPT Male or Female 1,2,4 R5413 Adjustable 1112"(38mm) %" (10mm) 2.8 40 1" NPT Male or Female 1,2,4 R5412 t;w W( co fl9OW llll I i I__ l.L 1 fr ___ OD :!i ccT T /7COR_'_ I7 fbfR Fig.1 — ½" NPT Non-Adjustable Inlet Fig. 2 — 1" NPT Male-Adjustable Inlet Fig. 3 - 1" NPT Female-Adjustable Inlet The equipment presented in this bulletin isto be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliablee The Reliable Automatic Sprinkler Co., Inc. (800) 43171588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address ® Recycled Paper Revision lines indicate updated or new data. EG. Printed in USA 05/05. P/N 9999970150 5prInkler Pipe $ 1":17ttIng.5 REVIEWED APPROVED APPROVED AS NOTED______________ NOT APPROVED - RESUBMIT___________ This checking and approval covers coordination of work, field dimensions, and layout. Conformance with design concept not checked. Weitz Company approval does not relieve Supplier of contractual obligations. SPECIFICATION REFERENCE )3_ C1j5 THE WEITZ COMPANY GENERAL CONTRACTORS By -A 1) Date _I2/OCe Checking is only for general confirmation with the design Concept of the Project and general compliance with the Information given In the Performance Specifications. TSUCHIYAMA KAINO SUN & CARTER CONSULTING MECHANICAL ENGINEERS _. &\\ \ 0 U. Comfl.tr LDV o Dyna-Thread $ Full Line Sch-40 Replaceme -------' Dyna-Thread' offers the life expectancy of Sch-40 with superior hydraulics and greater value. We -rP4 to 1J'b 1 cr1NJA- Htfkt t0A . Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Thread's inside diameter is up to 3.6% larger than Sch40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Scb40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. @ <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "AF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, thy deluge and pre-action sprinider systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40lDyna-1'hread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specificationsiri NPS Nominal I.D. WI. WI. (1120 Filled) Pcsi Wtitlft (21') Wt/tlft (24') WVI.ift (251) In; mm In; mm Lb&'Ff; Kg/rn .L.; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 11/4' 1.408 1.870 2.54 51 2002 2288 238 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 103 9. ' 16100 S. Lathrop. Harvey, IL 60426 Customer Service: tLICO/Flow Control cihleci 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 Dyna-Flow® High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 1W 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 1½' 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 2½" 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe was, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Ho is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. AdditionalI Benefits Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tqca a vital part of your world C") allied 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2 -3 'Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule- 10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1141_ 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-I 23. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF'. In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ Wt/LIfI (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2. 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2½' 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247' Specifications NPS Nominal I.D. WI. WI. (H20 Filled) PcW WI/Lift (21') WI/Lift (241) WI/Lift (251) In; mm In; mm Lbs/Ft Kg/rn Lbs/Ft Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1½" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21A" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule- 10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tLICc1 a vital part of your world Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: QT- cilhecJ 11350 Norcom Rd. ' Philadelphia, PA 19154 (800) 8825543 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 -1 rieiiteu DIMENSIONS IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 VICTAULIC9 IS AN ISO 9001 CERTIFIED COMPANY Style 005 FireLock® Rigid Coupling with Vic-Plus® Gasket System rGa!SfSystem PRODUCT DESCRIPTION FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. The FireLock couplings provide rigidity for valve connections, fire mains and long straight runs. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly; speeds and eases installation on pipe grooved to Victaulic specifications. Style 005 FireLock couplings with the Vic-Plus Gasket System are designed and recommended for use ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic® now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic-Plus' System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements. § LPC and VdS Approved, Request Victaulic see notes on page 2. publication 10.01 for details. Dimensions Pipe Size Max. Max. Allow. Inches/mm - - Actual Nominal Outside Work. End Pipe End @ Bolt/Nut Aprx. Diameter Diameter Press. § * Load Sep. t No.. Size *1jt. to, Inches/mm Inches/mm PSI/kPa LbsJN lnimm Inches/mm X V Z thth9 11/4 1.660 350 755 0.05 3/ X 21/ 4 2.75 4.50 1.22- 1.88 32 42.4 2413 3310 1.2 70 114 148 1 0.5 11/2 1.900 350 990 0.05 - I8 X 21/4 3.00 475 1.22 188 40 48,3 2413 4415 1,2 76 121 148 0.5 2 2.375 350 1550 0.07 2 - /8 X 21/2 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 89 133 148 0,7 21/2 2.875 350 2270 0.07 . 3/ X 21/ 2 4.00 5.75 1.92 1.88 65 73.0 2413 10110 1,7 102 146 148 0,9 76,1 mm 3.000 350 2475 0.07 2 -/ X 21/2 4.13 5.75 1.88 1.9 76,1 2413 11010 1,7 105 146 148 0.9 3 3.500 350 3365 0.07 / 2 - X 21/ 2 4,63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 118 156 148 1.0 4 4.500 350 5565 0.16 2-/e X 21/2 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 146 184 54 1.4 108,0 mm 4.250 300 4255 0.16 2- 3/ X 21/3 5.63 7.25 2.13 3.1 108,0 2068 18940 4.1 143 164 54 1,4 5 125 5.563 300 7290 0.16 2 -1/2 X 2/4 6.88 9.00 2.13 4.5 141,3 2068 32445 4,1 175 229 54 2,0 133,0 mm 5.250 300 6495 0.16 2 -1/2 X 2/4 6.63 9.00 2.13 4.5 133.0 2068 28900 4.1 168 229 54 2.0 139,7mm 5.500 300 7125 0.16 2.1/2 X 2/4 6.88 9.00 2,13 4.8 139.7 2068 31715 4.1 175 229 54 2,2 6 6.625 300 10340 0.16 2 . 1/2 X 2/4 aoo iaoo 2.13 5.0 150 168,3 2068 46020 4.1 203 254 54 2.3 159,0 mm 6.250 300 9200 0.16 2 - 5/ X 41/4 7.63 1000 213 5.5 159.0 2068 40955 4.1 194 254 54 2,5 165,1 mm 6.500 300 9955 0.16 2 - 1/2 X 2/ 8.15 10.00 2.13 5.5 165.1 2068 44295 4.1 207 254 54 2.5 8 8.625 300 17525 0.19 2 -5/8 X 41/4 10.50 13.13 2.63 11.3 200 219.1 1 2068 78000 4,8 267 334 67 5,1 I FSCC UJ IIVLC UPI payec. WIL 110 I1JLIl 1P Rated for wet and dry sprinkler systems at 350 psi (2413 kPa) for 11/4 - 4 (32- 100 mm) sizes and 300 psi (2068 kPa) for 41/4 8 (108 - 200 mm) sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. S REGISTERED TRADEMARK OF VICTAUUC - 0 COPYRIGHT 2004 VICTAULJC - PRINTED IN USA - SKU $WCAS67MHPN 1538 REV H Victaulic Company of America Phone: 1-800-PICK-VIc (1-800-742-5842). Fax: 610-250-8817• e-mail: pickvic@victaulic.com Victaulic Company of Canada. Phone: 905-884-7444. Fax: 905-884-9774 e-mail: viccanada@victaulic.com Victaulic Europe- Phone:32-9-381-1500. Fax: 32-9-380-4438- e-mail: viceuro@victaulic.be VictaulicNnerica Latina Phone: 610-559-3300- Fax: 610-559-3608- e-mail: vical@victaulic.com uC LI • C Victaulic Asia Pacific- Phone: 86-21-58855151W Fax: 86-21-58851298- e-mail: vicap@victaulic.com MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-Pius Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure us- ing the Grade "E" Type A Vic-Plus Gasket System, requiring no field lubrication for most installation condi- tions. For dry services, Victaulic continues to recommend the use of Grade 'E" Type A FIushSeaI9 Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to -40"F (-40C). Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0F (-1 8"C) and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water, Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. LISTINGS/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressure- PSI Rated Working Pressure - PSI Rated Working Pressure - PSI Pipe Sch. Size Inches UL ULC FM Pipe Sch. Size Inches UL ULC FM Pipe Sch. Size Inches UL ULC FM 5 11/4 3 175 175 175 EL 11I4 -2 300 N/A N/A MT 11/4.2 300 N/A N/A 11/4 4 350 350 350 1 ET 11/4 -2 300 N/A N/A STF 11/44 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 300# N/A 300 Std 11/4 - 2 N/A N/A 300 BLT 11/4 - 2 300 300 N/A FF 11/4 .4 N/A N/A 300 TF 3 - 8 N/A N/A 300 DF 11/4 4 300 300 300 GAL-7 11/4.2 300 N/A N/A WLS 11/42 300 300 N/A DI 11/4. 2 300 300 N/A MLT 11/42 300 N/A N/A XL 11/4.3 300 300 300 EF 11/2 - 4 1750 N/A 175 MF 11/4 - 4 300 N/A 300* FM approved for service in 11/2 4" pipe. # UL Listed for service up to 4" pipe only. @UL Listed for service up to 3" only. PIPE SCHEDULE NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe BLT refers to Listed steel sprinkler pipe manufactured by Allied Tube & Conduit OF refers to Listed/Approved Dyna.Flow steel sprinkler pipe manufactured by Allied Tube & Conduit DT refers to Listed Dyna Thread steel sprinkler pipe manufactured by Allied Tube & Conduit EF refers to Listed/Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose Tube Co. EL refers to Listed Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Co. ET refers to Listed Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Co. EZ refers to Listed EZ-Flow steel sprinkler pipe manufactured by Northwest Pipe & Casing Co. FF refers to Listed Fire-Flo steel sprinkler pipe manufactured by Youngstown Tube Co. GAL-7 refers to Listed steel sprinkler pipe manufactured by ]DOD Systems, LLC MLT refers to Listed steel sprinkler pipe manufactured by Wheatland Tube Company MF refers to Listed Mega-Flow steel sprinkler pipe manfactured by Wheatland Tube Company MT refers to Listed Mega-Thread steel sprinkler pipe manufactured by Wheatland Tube Company STF refers to Listed Steady Flow steel sprinkler pipe manufactured by AMS Tube Corporation Steady Thread refers to Appproved steel sprinkler pipe manufactured by AMS Tube Corporation TF refers to Tea-Flow steel sprinkler pipe manufactured by Tex-Tube Company WLS refers to Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company XL refers to Listed XL or XL II steel sprinkler pipe manufactured by Allied Tube & Conduit Corp. NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t For field installation only. FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar (175 psi). WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. This product shall be manufactured by Victaulic Company. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Style 005 FireLock® Rigid Coupling Patent Pending c®Us ? See Victautic publication 10.01 for details. IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.60 VICTAULIC5 IS AN ISO 9W1 CERTIFIED COMPANY Style 009 FireLock EZTM Rigid Coupling (VicPIw Gasket System PRODUCT DESCRIPTION Style 009 Joint Assembled The Style 009 FireLock EZ rigid coupling is a revolutionary patent-pending new way to join fire protection piping systems in the quickest manner possible. The unique design permits the installer to assemble a joint without disassembling the bolts, nuts, gasket and housings. This installation-ready coupling is easily stabbed on pipe grooved to Victaulic specifications, which speeds and eases assembly. The Style 009 coupling reduces effort and eliminates the potential of dropped fasteners. The Style 009 provides rigidity with its angle bolt pad design. The Style 009 is rigid and does not accommodate expansion, contraction or angular deflection. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Style 009 FireLock EZ rigid couplings with the VIcPlusThl Gasket System are recommended for use ONLY on fire protection. systems, Vic-Plus Gasket System: Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The VicPlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and for dry pipe fire protection systems. Dimensions Inches/mm Nominal Size inches/mm Actual Outside Diameter inches/mm Max. Work. Press. * PSI/kPa Max. End Load LbsJN Allow. Pipe End Sep. f InJmm @ Boll/Nut No. - Size inches/mm Apr)L wWilli.t.Ea. LbsJkg Pro-assembled (Stab in condition) - Joint Assembled X Y X V Z 1114 32 1.660 42.4 300 2068 649 2888 0.10 2.54 2-3/a X 2 3.13 80 4.93 125 2.86 73 4.83 123 1.93 49 1.5 1 0.7 11/2 40 1.900 48.3 300 2068 851 3787 0.10 2.54 2- / X 2 3.38 86 5.16 131 3.11 79 5.07 129 1.86 47 1.7 0.8 2 50 2.375 60.3 300 2068 1329 5914 0. 3.05 12 2- X 21/2 99 3.88 5.81 148 359 91 68 144 1.86 47 1.9 0.9 21/2 65 2.875 73.0 300 2068 1948 8668 0.12 3.05 2-/ X 21/ 2 4.38 111 6.21 158 4.08 104 6.10 155 1.87 48 2.0 0.9 3 80 3.500 88.9 300 2068 2886 12842 0.12 3.05 2- 3/ X 21/2 5.03 128 88 175 4.70 119 6.78 1 172 1.88 1 48 2.3 1.0 4 100 4.500 114.3 300 2068 4771 21230 0.17 4.32 2-/e X 21/2 6.19 157 8.11 206 5.94 1 151 8.01 1 203 2.09 53 3.9 1.8 I r,erer 10 noms On oelow. DIMENSIONS L~_y Z 0 Style 009 Pre-assembled (Stab in condition) NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roil or Cut grooved In accordance with Victaulic specifications. See page 2 of this document for Listed/Approved ratings on other pipe. WARNING FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate ex-pansion or Contraction of the piping system. @ Number of bolts required equals number of housing segments. NOTE: When assembling Style 009 Couplings Onto FireLock end caps, take additional care to make certain the cap is fully seated against the gasket end stop. Please make certain the 4 No. 006 cap includes an "Er mark on its reverse side to ensure compatibility. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. S REGISTERED TRADEMARK OF VICTAUUC - C COPYRIGHT 2005 VICTAUUC - PRINTED IN U.S.A. - SKU #WCA56030A2 3999 REV B United States • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail: piclwic@victaulic.com Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaullc.com Europe • Phone: 32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be UK • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e-mail: viceuro@victaulic.be Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vicalvictaullccom Australasia • Phone: 86-21-54253300 Ext 202 • Fax: 86-21-54253671 e e-mail: vicap@victaulic.com MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel Gasket: Grade "E" EPDM - Type All FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure using the Grade "E" Type A Vic-Plus Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard Style 009 gasket approved for dry pipe systems to -40°F/-40°C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-1 8"C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. LISTINGS/APPROVALS # The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Pipe Sch. Size Inches Pressure Rating - psi Pipe Sch. Size inches Pressure Rating - psi Pipe Sch. Size Inches Pressure Rating - psi UL ULC - FM UL - ULC - FM - UL - ULC FM 5 11/-2 175 175 175 EZT 11/4 .2 300 300 300 MT 11/4 .2 300 300 1 300 10.40 11/4 4 300 300 300 FF 11/4 -4 300 300 300 MLT 11/4 -2 300 300 300 BLT 11/.2 1 300 300 300 FLF V/2 -4 -4 N/A N/A 300 ST 11/4 -21 N/A N/A 300 DF 11/4 4 300 300 1 300 1 FLT 11/42 N/A N/A 300 STF 11/2 .4 N/A N/A 300 DT 11/4 -2 300 300 300 FLTL 11/4 -2 N/A N/A 300 TF 21/2 .4 N/A N/A 300 EF 11/4.4 175 175 175 GL 1/4 2 300 300 300 WLS 11/4.2 300 1 300 1 300 EL 11/4.2 300 300 300 55 11/4 -2 175 175 175 WST 11/4.2 175 175 175 ET40 11/4.2 1 300 300 300 57 Ill/,-2 300 300 300 XL 1 11/4 -21 300 300 300 EZF 1 3- 4 1 300 1 300 1 300 1 MF 1 1h/44 1 300 300 300 PIPE SCHEDULE NOTES: 5 refers to Listed/Approved Schedule 5 steel sprinkler pipe 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe BLT refers to Listed/Approved BLT steel sprinkler pipe manufactured by Allied Tube & Conduit DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by Allied Tube & Conduit OT refers to Usted/Approved Dyna-Thread steel sprinkler pipe manufactured by Allied Tube & Conduit EF refers to Listed/Approved Eddy Flow steel sprinkler pipe manufactured by Bull Moose Tube Company EL refers to Listed/Approved Eddylite steel sprinkler pipe manufactured by Bull Moose Tube Company ET40 refers to Listed/Approved Eddythread 40 steel sprinkler pipe manufactured by Bull Moose Tube Company EZF refers to Listed/Approved EZ-Row steel sprinkler pipe manufactured by Northwest Pipe Company EZT refers to Listed/Approved EZ-Thread steel sprinkler pipe manufactured by Youngstown Tube Company FF refers to Listed/Approved Fire-Plo steel sprinkler pipe manufactured by Youngstown Tube Company FLF refers to Approved Fireline Fireflow steel sprinkler pipe manufactured by Western International Forest Products FLT refers to Approved Rreline Rapid-Thread steel sprinkler pipe manufactured by Western International Forest Products FLTL refers to Approved Fireline Rapid-Thread Light steel sprinkler pipe manufactured by Western International Forest Products GL or MLT refers to Listed/Approved GL and MLT steel sprinkler pipe manufactured by Wheatland Tube Company GB or G7 refers to Listed/Approved GAL 5 and GAL 7 steel sprinkler pipe manufactured by Idod Systems, LLC MF refers to Listed/Approved Mega-Flow steel sprinkler pipe manufactured by Wheatland Tube Company MT refers to Listed/Approved Mega-Thread steel sprinkler pipe manufactured by Wheatland Tube Company STF refers to Approved Steady-Thread steel sprinkler pipe manufactured by AMS Tube Company ST refers to Approved Steady-Row steel sprinkler pipe manufactured by AMS Tube Company TF refers to Approved Tex-Flow steel sprinkler pipe manufactured by Tex Tube Company WLS refers to Usted/Approved WLS steel sprinkler pipe manufactured by Wheatland Tube Company WST refers to Listed/Approved WST (schedule 5) steel sprinkler pipe manufactured by Wheatland Tube Company XL refers to Listed/Approved XL steel sprinkler pipe manufactured by Allied Tube & Conduit t Listed/Approved for wet and dry pipe systems. Victaulic recommends the use of Style 009 rigid couplings on systems operating above 0°F/-18"C. For rigid pipe connections in systems operating below 0"F/-180C Victaulic recommends Style 005 FireLock rigid couplings with Grade "L" silicone gaskets. *Please refer to the Victaulic Reid Installation Handbook (1-100) for details concerning when supplemental lubrication is required. Style 009 FireLock EZTM Rigid Coupling 2 -8" Sizes IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS &I!Xi1 VICTAULIC° IS AN ISO 9001 CERTIFIED COMPANY Vic Nut \Gaset System PATENTED Style 744 FireLock® Flange Adapter with Vic.PlusTM Gasket System PRODUCT DESCRIPTION Style 744 FireLock Flange adapter is designed for directly incorporating flanged components with ANSI CL. 125 or CL. 150 bolt hole patterns into a grooved pipe system. Sizes 2 - 8" (50 - 200 mm) are hinged for easy handling with integral end tabs which facilitate assembly. The design incorporates small teeth inside the key shoulder I.D. to prevent rotation. Because of the outside flange dimension, FireLock Flange adapters should not be used on FireLock fittings. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. FireLock Flange adapters should not be used as anchor points for tie-rods across nonrestrained joints. Mating rubber faced flanges, valves, etc., require the use of a FireLock Flange washer. FireLock Flange adapters with Vic-Plus gaskets do not require lubrication. The gasket must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. Style 744 FireLock Flange Adapters with the Vic-Plusm Gasket System are designed and recommended for use ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic® now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic- Plus System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements. See Victaulic Publication 10.01 for details. Scaling Surface Dimensions Pipe Size MaL Work Max. End Incheslmm lnches!milhineters - - Wgt. Actual Nominal Outside Press." Load" No. Bolt Each Diameter Diameter PSI Lbs. Bolts Size? "A" '"B"' Lbs. bum huinvn kPa N Req'd. Inches Max. Mm. W X Y Z kg 2 2.375 175 775 4 X 2 / 00 4.754.75 0.75 2.7 50 60,3 1200 3450 60 87 172 152 121 19 1.2 21/2 2.875 175 1135 4 /s X3 2.88 3.91 7.88 7.00 5.50 0.88 4.2 65 73.0 1200 5050 73 99 200 178 140 22 1.9 3 3.500 175 1685 4 5/0 X3 3.50 4.53 8.44 7.50 600 094 48 80 88.9 1200 7500 89 115 214 191 152 24 2.2 4 4.500 8 518 X3 0 53 94 0 04 fl 100 114.3 1200 11045 114 141 252 229 191 24 3.2 5 5.563 175 4250 8 3/4 X 31/2 556 6.71 1100 110.00 8.50 1.00 8.3 125 141.3 1200 18920 141 171 279 254 216 25 3.8 6.625 175 6030 8 X 3 31/2 /4 63 778 0 0 90 100 9.3 150 168,3 1200 26840 168 198 305 279 241 25 4.2 8.625 175 110219 8 3/4 X 31/2 863 1 994 1463 13.50 11.75 113 13.9 200 219,1 1 1200 45475 219 252 1312 343 298 29 6,3 WLl LU i IULt1 UeIUw. tlotal bolts required to be supplied by installer. Bolt sizes for conventional flange-to-flange connection. Larger bolts are required when Vic-Flange adapter is utilized with waler-type valves. # Not available with Vic-Plus gasket system. Lubrication is required. DIMENSIONS Style 744 Sizes 2 - 8" (50 - 200 mm) ANSI Class 125 and 150 Flange 0!bEi 'L1J Note: Gray area of mating lace must be free from gouges, undulations or deformities of any type for effective sealing. NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. style 144 FireLock Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement at the joint. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. o REGISTERED TRADEMARK OF V1CTAUUC - C COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S.A. 1477 REV 0 Victaulic Company of America' Phone: 1-800-PICK-VIC (1-800-742-5842). Fax: 610-250-8817 - e-mail:pickvic@victaulic.com Victaulic Company of Canada- Phone: 905-884-7444. Fax: 905-884-9774• e-mail: viccanada@victaulic.com Victaulic Europe- Phone:32-9-381-1500" Fax: 32-9-380-4438" e-mail: viceuro@victaulic.be Victaulic America Latina- Phone: 610-559-3300. Fax: 610-559.3608• e-mail: vical@victaulic.com Victaulic Asia Pacific- Phone: 65-6235-3035' Fax: 65-6235-0535• e-mail: vicap@victaulic.com X0 /_ Pan No, Size Sob, hO Wt. Pipe CD 80160 11 x 11' Grooved 40 2'J. 078 lb 1/' (1.660") 80161 1/ x 11/2' Grooved 80 2 'lie 095 lb 111(1 900°) 80162 2"x2'Grooved 80 2/' 1.42 1b. 2)2,.375') 80163 2W' x 2W' Grooved 80 2'/4" 2.28 lb. 2W' (2.875") $0164 3' x:3' Grooved 80 2/4" 3.00 lb. 3' (3.500") 80168 3' x 76.1 mm Grooved 80 2W' 2.72 IbA 76.1mm (3.000°) Part No Size Sch. TIC WI. 80075 W 40 W 007 lb. 80076 40 1/iU 0.11 lb. 8007714' 40 '/.' 0.12 lb. 800781 1 1." 1 80 I" 1 025 lb. 80079 80 'f' 0.38 lb. 80080 2W' 80 i' 0.67 lb., 80081 3" 80 V." 0,91 lb. Grooved Coupling Adapter Coupling - - 1/0 - _ TVT/0 Cap -b Bushing Reducer Part No Size Sc'i. TO Wt, 80100 W 40 V" 0,04 b. 80101 1' 40 W' 0.06 lb. 80102 1/.' 40 1," 0.10 lb. 80103 1/4" 80 '/4° 0.20 lb. 60104 2 80 '/4" 0.31 lb. 80105 2W .80 W' 0.58 lb. 80106 80 1' 0.88 lb. Part Na Size Sch. 1/0 I Wt- 80200 x W 40 , 'M' 0.04 lb. 80201 1'6°0"' 40 ' 0.11 lb. 80202 1 h' x 1" 40 'Vi' 0.12 lb. 80203 V/; x /" 80 '1' 0,16 lb. 80204 1W x 1' 80 W 014 ID,. 80205 1 '4' x. 1 '/4" 80 W' 0.17 lb. 80206 x )/40 80 W' 0.27 lb. 60207 2x V 80 /4 ' 0.26 lb 80208 .2°X174' 80 4/' 0.2410. 80209 2° x I'ii" 80 0.19 lb. 80215 2/4° X 1' 80 1"R 0.42. lb. 80214 2/4' x 1'/4" 80 114- 0.45 lb. 60213 2'h° x. 1W' 80 i'/4° 0.46 lb. 80211 21/i' x 2" 80 11 .3' 0.29 lb., 80210 3°x2° 80 2W 0.72 11). 80212 3'x2'k" 80 UW 0.471b, Reducing lee Female Adapter Part No. Size Sob. TIC .Wt. 80142 W'x 3/."NPT 40 4" 0.41 1b. 80145 1'xlNPT W."x I'/,* NI PT 40 W 0.631b. 60146 W 1.03 lb. 80147 1'b x 1W NPT 80 1' 1.42 lb. 80148 , 2° x 2' NPT ' 80 1W 266 lb. Male .-. Adapter Part Na Szo Sob. T/C WI. 80157 '1." x -/4' NOT 40 11." 0.33 lb. 80158 1" x 1" NPI 40 1 1 /4" 0.56 lb. . T/0 Reducing - Coupling I I_... I_._I ... I Page 1 of 1 , Part No, Size - Sob. Tio WI. lb. 3 80132 '1" x /4" x 1° 40 W '/.' '/4" . 0,14 80133 V x x 'J/ 40 '6' ''/" W' 0.14 80,134 1' x W' xl' 40 4° W ' W' 0.17 80260 1" x 1" x 1/4" 40 1.6° /° 0.16 80135 11144 x. 1' x '.6° 40 'I' 6° "6" 0.21 80136 1'!." x 1" x 1' 40 "/' 'W 1'° 0.22 60137 lW x 1' x V.6' 40 'W I"' "/•' 0.26 80261 1 V4' x 1 '// x W' 40 111" W' '6" 0.23 80262 11-0 x 1'6" x 1" 40 W' W W' 0.26 80138 VA" x 1./i.' .x 1/,' 80 1" 1' V 0,43 80140 1W' x 17-1' x /' 80 1" V.' 1' 0.36 80141 17' x I'll x 1° 80 '/4" 14' 16" 0.38 80263 V/4* x 1/b' x '/4' 80 "/'b' '1." 1' 0.38 80264 i'll' x UI," x 1' 80 '/b' 1" 0.38 80275 U12"X1WXVI,' 80 '4' '/b' 1° . 0.45 80265 2° x2" x26" 80 'W '/4' i'/" 0.61 80266 2° x 2 x r 80 '/4' lb I 'lb 0.66 80274 2° x 2"x 1W 80 1" 1" VW, 0.74 80267 2° 2° x 1W 80 1W lW 1W' 0.78 80271 27/b' ,c 214" x V 80 V'/.b' V/b" V/b' 1.43 80272 2W' x 2W x 1W 80 1"/b' 1W' V/b' 1.46 80273 2/2" .* 2W' x v/b' 80 11194 i"/b' r/,b' 1,48 80278 21/? x 2/b' x 2° 80 1"/.b i"64" 1"Ib' 1,50 80270 3' x 3"x 1W 60 14" 1W' i'/b' 2.28 1S I I 'PS I I 1I IMt I http://www.tyco-fire.com/TFPgif/190 1590 1_3 .gif 5/16/2006 Page 1 of I Sprinkler Head Adapter with Brass Threaded Insert part NO. Sze - Sch. TIC WI, $0175E Y' x bH NPT 80 I 0.20 lb. 80176E V x I" NPT 80 V 0.2214. 80177W1. x'h" NT_ 40 0.16 lb. 80179 1 1 x NPT 40 0.43 lb. Sprinkler Head Adapter (Spigot) with Brass Threaded Insert Pail No. Size Sch T'O M. 8OI77L 1 /' x II NPT 40 1 1/ 0.16 lb 60178 V x If' NPT 40 0.20 lb. Sprinkler Head Adapter with Brass Threaded Insert Part No. Size Sch. T/C WI. 80175W /L x 'h NPT 40 7' 0.19 lb. 80176 rxfNPT 40 '/ 081b. - Part No. Size Sch. T/C WI. lb. 1 2 80462 1' x 1' x'/20 NPT x /,' NPT 40 'It' 1 /' 0.46 "3 t'x 1° x 1:' NPTx 1:' NPT 40 VI..• 0.47 I Back-to-Back Cross Li!I with Brass Threaded Insert Sprinkler Head Adapter 900 Elbow with Brass Threaded Insert Back-to-Back Tee with Brass Threaded Insert Part No, Size Sch. TIC I WI. lb. 1J -j 80199 W x 1' NPT 40 1 0-20 80189 V x 'I?' NPT 40 '1-' I 1b' 0.26 Part No. Size Sch 110 M. lb. 1 1 2 80459 1' x 1.' NPT x I NPT 40 / 1V 0.48 60460 V x Ii NPTx 1/:. NPT 40 11.' 11.' 0.46 Part No. - Size Sch. T/0. W1. lb. 1 2 1 3 0 V' x )f x W NPT 40 W W V 0,22 80251 V x V x /?" NPT 40 'I' 0.2 80249 60258 V x 1' x V NPT 1V x 1 x Y NPT 40 40 /'i/.' 1/ 0,73 80252 IWx 1V x '/ NPT 40 lW 0.31 80257 11W x 1W .x lh NPT 80 "Itt W 1V' 0.43 60254 1Wx 1W.xW' NPT 60 80258 2" x 1W x if NPT BC) if if 1W 0.56 80253 2 x 2' x li' NPT 80 if 'I' 1W 0.62 Sprinkler Head Adapter Tee with Brass Threaded Insert Limited Wranty Products manufactured by Tyco Fire Products are warranted solely to the orlinat Buyer for ten (10) years against defects in rnotartai and workmanship when paid lot andproporly installed and maintained under normal use and service This warranty will expire ton (10) years from date of shipment by Tyco Fire Products. No warranty Is 1von for product orcosnpononts rnarnducturod by companies not affiliated by ownership with Tyco The Products or for products and components which have been subject to misuse Improper Installation. corrosion or which have not been installed, malntainecL modified or repaired in accordance with opphcabto Standards of the National Fire Protoction Association (NFPAk aud!or the standards of any other Authorities ilcsvinij luslsdiction. Materials found by Tyco Fire Products to be detective shell be either repaIred or replaced at Tyco Fire Products sole option. Tyco Fire Products neither assumes. nor authorisos any person to assume for It any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or Inaccurate or Incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL. rico FIRE PRODUCTS RE UABLE. IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY FOR INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES. INCLUDING BUT Not UMITEt) TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES AND IN NO EVENT SHALL TYCO rUlE PRODUCtS L JUT? EXCEED AN AMOUNT EQUAL TO THE SALES PRICE THE FOREGOING WARRANTY 1SI4ADE IN liEU OF ANY AND ALL OTHER WARRANTIES.EXPRESS OR IMPLIED. INCLUDING WANTIER QE MEBCPAtTABIUTY http://www.tyco-fire.comITFP_gif/19_0 1 5_90 1_4.gif 5/16/2006 Hanyer.5 $ 5race Attachment5 IM Checking is only for general confirmation with the design Concept of the Project and general compliance with the information given in the Performance Specifications. TSUCHIYAMA KAINO SUN & CARTER CONSULTING MECHANICAL ENGINEERS L By J )31\J\ Date O(J REVIEWED APPROVED APPROVED AS NOTED NOT APPROVED - RESUBMIT This checking and approval covers coordination of work, field dimensions, and layout Conformance with design concept not checked. Weitz Company approval does not relieve Supplier of contractual obligations. SPECIFICATION REFERENCE )T g 15 THE WEITZ COMPANY GENERAL CONTRACTORS By_rn- Date 6/??1?) C® US USTED Component of State of California OSHPD Approved Seismic Restraints System Fig. 910 - Swivel Sway Brace Fitting Size Range - 1" and 1¼" bracing pipe. For brace pipe sizes larger than 11/4", use TOLCO Fig. 980. Material - Carbon Steel Function For bracing pipe against sway and seismic disturbances. The build- ing attachment component of a sway brace system; the Fig. 910 is used in conjunction with the Fig. 1001, Fig. 1000 or with a Fig 4A Pipe Clamp and joined together with a brace pipe per NFPA 13. Features - This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connec- tions. NFPA 13 (2002) Figure 9.3.5.9.1 indicates that fastener table load values are based only on concentric loading. Universal swivel design allows Fig. 910 to be attached at any surface angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions -The Fig. 910 is a structural or transitional attachment component of a longitudinal or lateral sway brace assembly. II is intended to be combined with the "bracing pipe", and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install —Thread the pipe into the Fig. 910 until pipe threads are visible through inspection site hole. Attachment can pivot for adjustment to proper brace angle. Note -The Fig. 910 Swivel Attachment and the Fig. 1001, Fig. 1000, or Fig. 4A Pipe Clamp make up a sway brace system of (UL) Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish - Plain Note - Available in Electro-Galvanized and HDG finish or StainlesL. Steel materials. Order By - Figure number, pipe size and finish. Lateral Brace Dimensions Weights D Hole Max. Design Approx. Pipe Size A B C Size E F Load Lbs. Wt./100 1 2 116 3 9/16 2316 2 2015 88 1¼ 1316 1316 3 9/16 2316 2316 2015 99 NOTE - Available with hole sizes to accommondate up to 3/4' fastener. Consult factory TOLCO® brand bracing components are desgined to be compatible QNLI with other TOLCO® brand bracing components, resulting in a Usted seismic bracing assembly. DISCLAIMER - NIBCO does No warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall No be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE.. CORONA, CA 92819 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 WWWtOlco.com -1/2" THROUGH BOLT - EXISTING GLU-LAM BEAM UII1%.iL liLrAlYll EARTHQUAKE BRACE DETAIL NOT TO SCALE Fig. 1000 - "Fast Clamp" Sway Brace Attachment Size Range - Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 1 ¼" Schedule 40 IPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation —The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete brac- ing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Tighten hex nuts until leaf spring is flat. It is recom- mended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load 1" thru 4" pipe size - 2015 lbs. 6" size - 1265 lbs. TOLCO® brand bracing components are desgined to be compatible 9M with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NE warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall No be liable under any circumstance for any direct or indirect, Incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE.' CORONA, CA 92879' PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com Fig. 4L Longitudinal "In-Line" Sway Brace Attachment Size Range - 2W through 8" IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Features -This product's design incorporates concentric loading of the "brace pipe", connection components and fasteners which is critical to the performance of seismic bracing assemblies. Approvals - Underwriter's. Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" through 8". Installation - The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in electro-galvanized and HDG finish. Order By - Figure number, pipe size and finish. 4-Way Riser Brace (Plan view) Longitudinal Brace Dimensions • Weights Bolt Max. Rec. Approx. Sizes A C D Size Load Lbs. wt./100 236 67/16 2½ 2A 1/2 2015 253 3 7 2Y4 ,3Y16 1/2 2015 268 4 8½ 39's 31Yi6 1/2 2015 348 5 9Y4 3½ 4% 1/2 2015 380 6 11½ 5 5½ 1/2 2015 640 8 13¼ 61Yie 6½ 1/2 2015 728 TOLCOO brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting In a Listed seis-mic bracing assembly. DISCLAIMER - NIBCO does No warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NQI be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.7370330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com race Fig. 980 - Universal Swivel Sway Brace Attachment steel up to 1/4" thick. Size Range - One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural Component of State of California OSHPD Approved Seismic Restraints System Material - Carbon Steel Function - Multi-functional attachment to structure or braced pipe fitting. Features -This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation - The Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note —The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish — Plain Note -Available in Electro-Galvanized finish. Order By - Figure number and finish. Patent #6,273,372 Dimensions -Weights Max. Design Approx. A B H* Load Lbs. Wt./100 5¼ 1½ 17/32 2765 132 Available with hole sizes to accommodate up to 3I4 fastener. Consult factory. TOLCOO brand bracing components are desgined to be compatible QW with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599' FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 157 wwwtolco.com 2 12 TF1U B INCH PIPE A 12 THU 2 INCH PIPE Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21I2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals— Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31l8 25/, 400 11 3/4 3/8 8mm or 10mm 31/8 2V2 400 11 1 3/8 8mm or 10mm 33/, 21/, 400 12 l'14 3/8 8mm or 10mm 33/4 2/9 400 13 11l 3/8 8mm or 10mm 31/, 21/, 400 14 2 . 3/8 8mm or 10mm 41/3 3 400 15 21/2 3/8 10mm 5/ 41/ 600 27 3 3/8 10mm 57!, 4 600 29 31/2 3/8 10mm 73/, 51/4 600 34 4 3/8 10mm 734 5 1000 35 5 1/2 12mm 91/, 6/4 1250 66 6 1/2 12mm 101 /, 6/4 1250 73 8 1/2 12mm 131/, 8'/4. 1250 136 Office/Manufacturing Facility '1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 WCustomer Service. 800.786.5266 www.tolco.com Fig. 58 -Threaded Side Beam Bracket Size Range - 3/8" rod, pipe sizes 1/2" thru 4" Material - Carbon Steel Function - Practical and economical bracket used to support piping from wood, concrete or steel beams. Features - Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2" thru 2" pipe requires 3/8" fastener, 21/2" thru 4" pipe requires 1/2" fastener.* Approvals -. Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note - Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish - Plain Note - Available in Electro-Galvanized finish. Order By - Figure number and finish Dimensions • Weights Pipe Size Qty. Fastener Type Material 2 2 21I -4 2. 1 1 #16 x 2 Drive Screws 3/8 Lag Bolt 1/2 Lag Bolt Wood Wood Wood 31Il 4 4 4 2 2 2 2 114 x I 1 Lag Bolt 1/4 x 2 Lag Bolts* 1/4 x 1 tek screws 1/4 x 1 tek screws Wood Wood 14 gauge 16 gauge * No pre-drilling required Dimensions 'Weights Pipe Rod Size Size A . Max. Rec. Approx. B C Load Lbs. Wt./100 1/2 thru 4 3/8 2/4 11/2 I 1 .300 14 2-1.14x.2La-qBe1a (tIc Pre.dr4ling) up 104 och Pipe Per I*PA i.LagBoit Up To 4 inch Pipe 2- WH3 x 2 Oivè Screws 11,'2 Thru 2 inch Pipe :--- .-' 2-464*1 -- Tek Type Screw* Into Min. 56(a Steel Up To 4 inch Pipe Bolt 8 Hex Nut Up To 4 inch Pipe D Office/Manufacturing FacIlity. 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 Www.lolco.com Component of State of Fig. 4 - Standard Pipe Clamp callfornlaoSHpDApproved c®USLISTED Fig. 4F - Standard Pipe Clamp Felt Lined Seismic Restraints SYstem Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range - (Fig. 4) Size 1/2" thru 30" pipe, Size Range - (Fig. 4F) Size 1/2" thru 21h" copper tubing Material - Carbon Steel Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use Fig. 330 WeIdless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye A Rod.) Also recommended for attachment of sway bracing up to 31/2" pipe size, for larger pipe sizes use Fig 4A Fig 4F and Fig 4PVC are designed to reduce noise and vibration . and/or prevent electrolysis. .. Approvals - Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 3/4" - 8", /1 and approved by Factory Mutual Engineering 3/4" - 8" Federal Specification WW-1-1-171E, Type 4, 11h" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included C V. in our Seismic Restraints Catalog approved by the State of California Office of Statewide ) Health Planning and Develooment (OSHPD). For additional load. soac- Fig. 4 ing and placement information relating to OSHPD Drojects please refer to the TOLCO Seismic Restraint Systems Guidelines Note - When the Fig 4 is used as a sway brace, to ensure perfor- mance, the UL Listing requires that It must be used with other TOLCOTm brace products Maximum Temperature - 750°F ' Finish - Plain N( Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, pipe size and finish. Fig. 4F Order Note - When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Fig. 4PVC Dimensions 'Weights Pipe Max. Design Load Lbs. Size A B C D For Service Temp. Approx. Bolt Size 6500 750°F WtJIOO 1/2 3/16 1/4 1¼ 1¼ 5/16 500 445 29 3/4 3 1/4 1¼ 114 5/16 500 445 31 1 391a 1/4 1¼ 5/16 500 445 35 11/4 43/le 1/2 13A 113/ia 5/16 500 445 40 1½ 49/le 5/16 1% 1¼ 5/16 800 715 42 2* 5V1a 1/2 2 2¼ 3/8 1040 930 93 21h* 67A6 9/16 2½ 2Y4 1/2 1040 930 126 3* 7 5/8 2-Y4 33/16 1/2 1040 930 141 3½* 713/16 3/8 3½ 3H 1/2 1040 930 154 4 8½ 5/8 3,l6 313'a 1/2 1040 930 229 5 9Y4 3/4 37A 4% 5/8 1040 930 261 6 11% 3/4 47A 5¼ 3/4 1615 1440 537 8 13A6 1 5¼ 6 3/4 1615 1440 625 10 16½ 1 7¼ 7¼ 7/8 2490 2220 1378 12 18½ 1 8¼ 8¼ 7/8 2490 2220 1574 14 20 1½ 9 9 7/8 2490 2220 2103. 16 23 134 101/4 1O'A 7/6 2490 2220 2314 .18 257A 11/4 1116 1116 1 .3060 2730 3276 20 28 1_N 121A 121h 1¼ 3060 2730 3863 24 3316 1% 151/4 151/4 1¼ 3060 2730 5222 30 417A 2 19 19 1N 3500 3360 10511 'Meets UL 203A requirements for attathment of sway bracing. Horizontal design load for 1/2'-2" - 380#, 21/2" - 395#. 3' . 435#, 31,.2" - .54 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599.. FAX: 951737.0330 CUSTOMER SERViCE' 800.786.5265 www.tolco.com WL)i - teei 6 Page 1 of 3 Up Juniors 7he e I trock ] r Home j ( Ceiling Screws Sammy Assortmentj Hurricane Pole Tool Sammy Xpress GS T Wood Sammy. F Sammy Saddle I F Sammy Swivel Head] J DST Steel Sammy I SWG Wood SW L SWDR Steel SW ST Concrete Samm Iswc - Concrete SW] I 55 Wood j SS Steel All-thread Rod Anchoring Systems 4 Steel Sidewinder - Self drilling & self-taping into steel Steel • 1/4" Rod • Horizontal Mount Use #14SW Nut Driver (Item #101) Item Model Screw Rod Shank Minimum Max Actual No Description Size Diameter Thickness Thickness Shear Pullout 2003 SWD 100 1/4-14 x 1 1/4-20 1/4 .066" - 16 ga. 1/4" 1477#/ 16 ga. _a 407 SWD 200 1/4-14 x 2 1/4-20 1/4 .066" - 16 ga 1/4" 1477#I 16 ga. #I4SW 206 1 100 SWDR 1/4-20 1/4-20 1/4 .036 -20 ga. 1/4" 1900# /20 _____ ga. Item #101 http://www.sammysuperscrew.comJSWDR.htm 6/17/2005 - steel sW 1'age 2 ot• 3 Steel• 3/8" Rod • Horizontal Mount Use #14SW Nut Driver (Item #101) [tern Rod .Description Test w4rIv9 r Pipe hear/PullouModel flimumI ices Max. hick. Actual LoadNoSize (lb) Size 39 S 10 3/8 '/4-14x1 .066"- l6ga 1/4 1477#/l6ga. 40 SWD 15 16 ¼-14x1Y2 Note: Screw diameter/design/performance for DST _ 41 SW!) 20 ¼-14x2 10 (1" length) through DST 30 (3" length) are 16 1 constant. Only the lengths valy. #14SW Item 42 SWD 516 5/16-18x1¼ 16 __ #101 ®- 46 SWDR 3/8- ¼-20x1'/21500/1475 4 - 1/2" 2375#/¼" 1½" 16 1036 11900# SWDR " __ 43 ¼-20x1 1500/1475 4 -- .1/4" / 20 ga 16 20g2 - 44 SWDR 3/8- 5 /16 18x1¼ 1500/1475 4 .036"- 1/4" 2480# / 20 ga. 516 16 20ga 45 SWT 15 3/8- 12-24xlV2 .2511-1 4" 1/2" 16 1 IWhen installing DSTR or SWDR add retainer nut and torque to 20 foot lbs. for maxim uin Click on SL symbol to link direct to UL Online Certification - Legend 41 Factory Mutal Approved UL-listed. Available in Stainless Steel. • - Box quantity 25. Standard box quantity 125, except where so indicated. 2005 Factory Mutual and UL listed approvals - pdf (753 Kb) HORIZONTAL MOUNT.pf (753 Kb) Installation Instructions DST, DSTR, TEK 50, SWD, SWDR, SWT See Figures 1 through 4 (vertical) and 11 through 14 (horizontal) of detailed installation instructions for illustrations. • DST self-drills & self-taps into steel up to 116 thick. DSTR self-drills & self-taps into steel up to 1 16 thick and accepts retainer nut. TEK 50 - Self-drills & self- taps into steel up to thick. SWD self-drills & self-taps through '16 steel. SWDR self-drills & self-taps through '16 steel and accepts retainer nut. SW!' self-drills & self-taps through 1/z?1 steel. http://www.sammysuperscrew.comJSWDR.htm 6/17/2005 WVK - steei w Page 3 of IStep 1: Insert the appropriate nut driver into a 3/8" or %" portable drill: use #14 Nut Driver for DST, DSTR., TEK 50; use #14SW Nut Driver for SWD, SWDR, SWT. Step 2: Insert the screw into the nut driver. Now you are ready to install the screw. Step 3: Position drill and begin installation: for installing DST, TEK 50, DSTR*, the drill should be in a vertical position; for installing SWD, SWDR*, SWT, the drill should be in a horizontal position at a right angle to the structural member. 4; When the nut driver spins freely on the cap of the screw installation is complete. Step 5: Screw is now ready to receive ¼", 3/811, V2 It or metric all-thread rod or bolt stock. Warranty compliance requires that appropriate nut drivers be used, for all installations, Download CAD Drawing-4 Installation Instructigns Safety Information Performance Data Home Juniors Sheetrock I f Hurricane Ceiling Screws Pole Tool J Sammy Assortment J Sammy Saddle Sammy Xpress J [ammy Swivel Head f GST Wood Sammy SWG Wood SW DST Steel Sammy LSWDR Ste& èj ST Concrete Samm SWC Concrete SW SSWoocl ( 55 Steel 1 Information: submit a request or contact, cpinto@itwbui1dex.com f41F ICRAJ Last modified: January 24, 2005 ' - .1 1-.-" . An independent, non-profit content rating organization. Copyright 02002-2005: ITW BUildex. All trademarks or registered trademarks used are trademarks of Sammy Super Screw®, ITW Buildex and Illinois Tool Works, Inc. IILDjtj1&iivacy Policy ITW Buildex uses WebTrends Live to analyze traffic to this web site. WebTrends Live does not create individual profiles for visitors. Unlike some tracking services WebTrends Live does not have a database of individual profiles for each visitor. WebTrends Live only collects aggregate data. For more information about WebTr ends Live Privacy policy, please click here, Send mail to: kehnisz(niitwbuiidex.com MAT with questions or comments about the webpage. http://www.sammysuperscrew.comJsWDR.htm 6/17/2005 renormance vata rage I Or L Home if Up j[ Horizontal Vefflcalj LmaD] All-thread Rod Anchoring Systems Performance Data For Steel Sheet SteelGauges Gauge Number ¼ 12 14 16 18 20 22 24 26 Decimal Equivalent .25 .188 .105" .075" .060" .048" .036" .030" .024" .018" Ultimate Pullout Values - SammysTM (aver age lbs.ultimate) Fastener - - Steel Gauge - - Model Dia. Pt. 20 18 16 14 1 12 '16 1/4 DST '4 #3 446 613 970 1145 1544 3190 DST 516 1I6 #3 664 1500 TEK 50 #12 #5 487 699 913 1527 32701359L3 )STR1%" #12 #5 3270 3593 DSTR1" '/ #3 11510 DSTR 516 51,6 #31220-01 Ultimate Pullout Values (averagelbs.ultimate) Fastener Aluminum Curtain Wall Extrusion Model 114 .092 365 .132 DST 10 DiajPt. ¼ 1265 2750 SWD 10_ _ '/, _#3 _#3 - 1120 - 1420 Ultimate Shear/Pullout Values - Sidewinders (averagelbs.ultimate) Fastener Steel Gauge Model Diam. Pt. 20 18 16 14 12 '16 '4 SWD '/ #3 1477 SWDR 1%" #12 #5 2375 SWDR1" 1/4 #3 1900 1900 SWDR 516 '16 #3 2480 2480 http://www.sammysuprscrew.comJperformancedata.htm 6/17/2005 i-'errormance vata ?age 2 of 2 t I p Home Horizontal Vertical Performance Da- F ta Information: submit a request or contact, dpinto@itwbuildex.com Last modified: January 24, 2005 ______________ - An independent, non-profit content rating organization. Copyright 02002-2005: ITW Buildex. All trademarks or registered trademarks used are trademarks of Sammy Super Screw®, ITW Buildex and Illinois Tool Works, Inc. ITW Buildex Privacy Polia ITW Bulldei uses WebTrends Live to analyze traffic to this web site. WebTrends Live does not create individual profiles for visitors. Unlike some tracking services WebTrends Live does not have a database of individual profiles for each visitor. WebTrends Live only collects aggregate data. For more information about WebTrends Live privacy policy, please click here. Send mail to: kehniszAitwbuildex.com MAIP with questions or comments about the webpage. 6/17/2005 Fig. 28 "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe c USUSTED Size Range - W through 2" Material - Carbon Steel, Pre-Galvanized Function - Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces. A Unique twist and lock design holds pipe firmly in place and allows retrofit type .. B of installation. The "Stand-Off' design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting surface orientation. Attaches easily to wood structure with two hex head self-threading screws furnished with product. . Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe Attaches easily to steel minimum 18 gauge with (2)1/4" x 1" tek type self drilling tapping screws U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals - Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2)1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL / vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint ,. when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint Use one Fig 27B Speed Nut on the upper installed screw when used as a hanger only. Order by - Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. ------------ 1.1 Ol.IED rG.270 : UGh OlD ..-.,, 2) RZOIREO or tM4GC Dimensions • Weights HANGER APPLICATION HANGER&RE91RANT Pipe APPLICATION A B Approx. C - Size 3/4 3%2 2 31/2 .180 1 3i6 2316 3½ 210 1¼ 3% 2H I - - - - - 1½ 4 216 3½ .225 31/2 310 I ' 2 4½ 211,163% .340 - F1026 OFF10EIMANUFACTURING FACILITY • 1375 SAMPSON AVE. CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951,737.0330 CUSTOMER SERVICE * 800.786.5266 www.folco.com DER 5/8 I 518 Fig. 22C - Combination Hanger & Restrainer Application C®U$ USTED Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Designed to support a CPVC pipe away from the corner of a beam. This position allows for easy installation of drops or risers without adding additional wood blocks. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) for use as a combination hanger and restrainer. Finish - Pre-Galvanized Note - Approved UL Listed fastener into wood is furnished with the product. A fastener into light gauge metal may be ordered separately. Minimum acceptable #10 x 1" hardened self threading screw with 5/16" hex washer head. Order By - Fig. 22C application is composed of two standard Fig. 22 models - order two singles for each hanger and restrainer application required. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount C@ US LISTED Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 130. Features - Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights cpvc Max. Hanger Fastener Hex Approx. Pipe Size A B - C Spacing (Ft.) Head Size Wt./100 3/4 2o4 1%2 13e 5½ 5/16 9 1 2% 1i6 1yl6 6 5/16 9 1¼ 3 1½ 13/16 616 5/16 11 1½ 3¼ 1% 13e 7 5/16 12 2 31V16 127A2 131e 8 5/16 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE.. CORONA CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE . 800.786.5266 www.tolco.com / Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x I" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. C®US LISTED Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 3½ 1316 1316 5½ 5/16 9 1 33 131e 1316 6 5/16 9 114 4916 2912 1316 616 5/16 11 116 4,16 2912 131e 7 5/16 12 2 491 27/16 1916 8 5/16 15 OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE.. CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.7370330 CUSTOMER SERVICE • 800.786.5266 www.toicaccn, V491V&5 $ Acce,55one5 0 cbr('m1 REVIEWED________________ APPROVED______________________ APPROVED AS NOTED____________ NOT APPROVED - RESUBMIT_________ This checking and approval covers coord,r of work, field dimensions, and Conformance with design concept not chcc..: Weitz Company approval does not reiev Supplier of contractual obligations. SPECIFICATION REFERENCE I2 915 THE WEITZ COMPANY GENERAL CONTRACTQtS,Jb By ''U Date S Checking is only for general confirmation with the design Concept of the Project and general compliance with the information given in the Performance Specifications. TSUCHIYAMA KAINO SUN & CARTER CONSULTING MECHANICAL ENGINEERS MODEL 1011 0 Ir J The AGF Manufacturing Inc. Model 1011 Matches All The Features And Benefits Of Our Model 1000 by Providing Both The Test Function And The Express Drain Function In A Multistory Installation, With The Added Feature Of An Integral Model 7.000 Pressure Relief Valve With Drainage Piping. Available In A Full Range Of Sizes From 3/4"To 2", NPT & BSPT, With All Specifiable Orifice Sizes /84, 7/16', i/f, 11/32", 5/s" (ELO), & 3/4" (ESFR). The Model 1011 Complies With The Requirements Of NFPA 13,13R, & 131), Which Stipulate A Pressure Relief Valve Be installed On All Gridded Systems And Downstream Of All Pressure Reducing Valves. The Model 1011 Is A Single Handle Ball Valve That Is Lightweight And Compact, Which Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glass, And Is 300 PSI Rated. The Included LJLJFM Model 7000 Pressure Relief Valve Features A Flushing Handle And Is Factory Set At 175 PSI, Other Pressure Settings Are Also Available. Designed To Relieve Excess System Pressure Caused By Surges Or Temperature Changes As Well As Solve The Difficult Problem Of Providing The Relief Valve With A Drainage-Piping Outlet. The Unit Comes Shipped In A Semi-Assembled State With The Relief Valve And The Bypass Drain Ports Plugged. This Is Done To Ease Pressqre Testing The System. ONA our New ,0 GVWUN it an No kdemd 8/01 P MODEL 1011 WSTiADRAIN. ®. MODEL 1011 (UL LISTED/FM APPROVED) BRONZE BALL VALVE Pr CoLl çot .,t/L?cv or V(c.Fci1i'c /3(c_I' CCJ9rf .GFH3 PLAN VIEW MODEL 7000 (UL LISTED/FM APPROVED) PRESSURE I FACTORY SET AT 175 PSI WITH OTHER SETTINGS AVAILABLE. WE lAy-c NO L1c99T1O To PcfC::; IeST Pdt\ .3. FRONT VIEW- MODEL 1011 IIPr!i From the February 1, 1999 Edition of NFPA 1.: Chapter 4-1.2 Requires ALL GRIDDED SYSTEMS be provided with a relief valves Chapter 5-141.2.3 Requires a relief valve be Installed downstream of all pressure-reducing valves ORIFICE SIZES AVAILABLE _3/5, 746,1/2,17/32, E.LO(5/er ESTR(3/4)' DIMENSIONS - INCHES OERAU.LINGIH 1011 1011 SIZE A B C D E F G H MATERIAL LIST 3/4" 7 'i&•' 1 1/2" 2 'is" 3 /8" 3 31e 1 131io" 4 /" 6 'e' 191.30mm 37.58mm 55.65mm 93.23mm 85.88mm 45,30mm 111.12mm 162A2mm PART: MATERIAL' 1" ' 91le 1 1/2" 2 is" 3 54' 3 Iti" 1 1311d' 4 io" 6 1d' 1*1.30mfl 37.58mm 55.65mm 9323mm 85.88mm 45.30mm 117.12mm 162A2rnm HANDLE STEEL 1 1/4" 7 15•' 1 11Iio 2 118 4 1/4" 3 '18 1 15/16" 5 9/.j' ., 5 1/ STEM ROD BRASS _______ 201mm 42.70mm 65.36mm 1 106.36mm 82.84mm 50.89rmwn 141.39mm 192.28mm BAli.. BODY CA BRONZE Br2OP2E 8 15/a" 1 134ew 3 1/4" 5 1/160 3 71e 2 8" 8 1/40 10 74' VALVE SEAT IMPREGNATED TEFLON 226.68mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm INDICATOR PLATE STEEL 2" 8 1511e 1 13/16" 3 1/4" 5 1/a" 3 7/8" 2 54" 8 1/40 ,, 10 'a REUEFVAI.VE BRONZE 226.68mm 45.50mm 81.50mm 127mm 99.18mm 66.87mm 206.63mm 273.60mm BYPASS FITTINGS BThkSSVdBING BRASS NYI.OBRAID Ava5abIe on 1 1/4 'to 2 size units only- UL US1ING 5X4019(M) &EX4533(N) AGF MANUFACTURING COMPANY 100 Quaker Lane ------ Malvern, PA 19355 USA Telephone: (610) 240.4900 Fax: (610) 240-4906 www.testandraln.com MADE IN U.S.A. JOB NAME: ARCHITECT- ENGINEER: CONTRACTOR: FIG.4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. DC. 76t-4 URP011ER - The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG.i SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL OWO. p23-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 2 OPTIONAL TAMPER SWITCH RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY, USE THE MINIMUM AMOUNT OF RETARD NECESSARY To PREVENT FALSE ALARMS, A 0 SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO. 0. TO INSTALL. DRILL HOLE AS INDICATED: rPIPE SIZE HOLE SIZE 2 to 2 I/2 1 1/4 +1/8 -1/16 (50mm to 65mm) (33mm ±2mm) 3 to 8 2 ±1/8' (80mm to 200mm) 50mm *2mm) Cover Tamper (with cover in place) ffl DIRECTION OF WATERFLOW C NO NC (WHI) (RED) (eLK) va DWG. #761-30 DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL SOFT.-LBS (68 n-m) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) o o * 10-25 B 20-40 C 35-55 DIE 50_TO leo_SO FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to 2 —m or operate a central station, pro- su.Y0K4 WIUC1S cwl•. ito 0N TOM FRW 1W kn 1 .prletary or remote signaling unit, while the other contact is • used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electri- ON WKW &W 00 HOT AC — T cal entry must be sealed to M lUl CDKXMX n* cG,ucii exclude moisture. 4'I bL S l OTO — For supervised circuits see Switch Terminal Connec- tions'. drawing and caution note (Fig. 1). APPLICATION WARNINGI Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AIFF, deluge, or chemical suppression systems. TESTING The frequency 'of inspection and testing for the model VSR-F and' its associated protective monitoring system should be In accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspectors test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. 'If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gprn (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV PAGE 2 OF 2 MFG. #5400781 -7/02 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-340 to 660C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. INCHES VOLTAGE (mm)(3m) MODEL NO. STOCK NO. CURRENT (MAX.) TYPICAL dB AT1OFr. (2) MINIMUM dB ATIOFt (3-)(1) 6(150) 12VDC P80126 1706012 .12A 85 76 8(200) 12V06 P60128 1708012 .12A 90 77 10 (250) 12VDC PBD121O 1710012 .12A 92 78 6(150) 24VDC P6D246 1706024 .06A 87 77 8 (200) 24VDC PB0248 1708024 .06A 91 79 10(250) 24VDC P802410 1710024 .06A 94 80 6(150) 24VAC PBA246 1806024 .17A 91 78 8(200) 24VAC PBA248 1808024 .17A 94 77 10 (250) 24VAC P8A2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC PBA1208 1808120 .OSA 99 84 10 (250) 120VAC PBAI20I0 1810120 .OSA 99 86 BELLS (E)POTTER PBA-AC & PBD-DC The Symbol of Protection UL Listed Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120 VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -400 to 150°F (-400 to 66°C) (Outdooruse requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 688-882-1833 www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV S PAGE 1 OF 2 MFG. #5400776 -5/05 ®POTTER BELLS The Symbol of Protection DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONETHREADED 1/2" CONDUIT ENTRANCE 10 (2 0) I 33/8 8. (146) (86) (127 _ OJ ) (20) 61 I))J 5/8 (86) I 2 - (41) 4 I/4 11/16" (68) OV, g776-I (108) OWG. 0776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) -_ RED (OUT) WHITE (IN)M C 111WTE (OUT) OR END-OF-LINE OR OR FROM CONTROL P7ANEL 0 10 NEXT BELL FROM CONTROL PANEL K (OUT)BLACK (rN) RESISTOR PRECEDING BELL PRECWNG BELL ______________ O.ACK (OUT) BLACK (IN)_________ If ' CAUTION, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN NAO OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 2, RED WIRES POSITIVE (+) 3. BLACK WIRES NEGATIVE (-) CAIN, WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS, DWG. #776-3 INSTALLATION The bell shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shall be no less than 90" Aff and not less than 6" below the ceiling. Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REVS PAGE 2 OF 2 MFG. #5400776 -5/05 1 Ful MR Cerritos, C eiffornia Noonan Union, New Jersey Call Potter-Roemer for current listings and approvals. 7 Atlanta, Georgia - ••. Dimensions are subject to manufacturers tolerance L / Wood Dale, Illinois - and change without notice. We assume no responsi Re Proon Products - bfllty for use of superseded or void data. EXPOSED FIRE DEPT. INLET I CONNECTIONS-CLAPPER TYPE TWO-WAY WITH SINGLE CLAPPER REGULARLY FURNISHED: Cast brass two-way Inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by Figure Number. Lettering as selected. Size 4 x 21/2' x 21I2". 6¼' 6%, 10' OPTIONAL FINISHES: O - B Polished Brass - C Rough Chrome Plated - D Polished Chrome Plated LETTERING: E3 AUTO. SPXR. STANDPIPE THREADS: O NST Other Fig. 5710 ... Back Outlet U/i.. listed FM Approved O Fig. 5715 ... Angle Outlet U/L listed FM Approved "* TWO-WAY WITH DOUBLE CLAPPERS REGULARLY FURNISHED: Cast brass two-way Inlet body, drop clappers and pin lug swivels. Size and outlet as selected by Figure Number. Lettering as selected. u B11W A 7W [.3 OPTIONAL FINISHES: 0—B Polished Brass - C Rough Chrome Plated 0— D Polished Chrome Plated LETTERING: AUTO. SPKR. E3 STANDPIPE THREADS: 0 NST O Other FIg. 5720 Series Back Outlet C) Fig. 5730 Sadie 900 Angle Outlet Outlet - Approvals - - outiet Approvaft SIze A .A224. B C D Angle Flnko.ia (j) F=7 ' Annie Fla. No. ) JJ ttL <8> 5721 Yes Yes 5731 Yes IYes 4x21/2 x21h 7' 111I2 81/2 11114 5722 No No 5732 No No 6x21/2 x21/2 91/2 101/2 19 10/4 5723 No Yea 5133 No Yes 4x3 x3 91/2 11/2 91/2 11 5724 Yes No 5734 No No 6x 3 x 3 10 11 lOVe 11 ALL PIMENSIUNS IN INCHES REVISED REVIEWED 2-1-96 2-1-96 I OPTIONAL FINISHES: THREADS: 0—B Polished Brass DN.ST. 0—C Rough Chrome Plated 0 Other________________ 0—D Polished Chrome Plated i' Sin 101100911 Open A B C C 0 E 1½ 2¼ 3½ 61/k 71/2 2½ 2 2½ 3½ 5 9½ 11½ 3½ 2iW AU. DIMENSIONS IN INCHES ' POTTER ROEMER MEMBER iCerftos,Callfomia r 1 Union, New Jersey Protection I Fin (0) "1 (FaRe PCTEC1lON PIOdUCIS t'- HOSE VALVES ANGLE FEMALE X MALE DOUBLE FEMALE REGULARLY FURNIBHEDi Cut brass valve with red hand wheel Female N.P.T. inlet X male hose thread outlet. 300 lb. rated Fig 04060 .................................. 1½'Size 04065 ................................... 2½'Sin OPTIONAL FINISHES: 0— B Polished Brass 0—C Rough Chrome Plated E) —0 Polished Chrome Plated VARIATIONS: Extended stem up to 24', SPECIFY length ¼' petcock SPECIFY location I Size Cloud Open A B C C 0 E 11/2 2¼ 31h 6½ 7½ 21h 2 L 21/2 3½ 5 9½ 11½ 3½ 23A REGULARLY FURNISHED: Cast brass valve with red hand wheel. Female N.RT. Inlet and outlet. 300 lb. rated F 04070 .................................. 1½"Size 04075 ..................................2½' Size THREADS: DN.S.T. o Other- AU. DIMENSIONS IN INCHES Li—A —..J ADJUSTABLE PRESSURE RESTRICTING ANGLE VALVE FEMALE X MALE REGULARLY FURNISHED: Cast brass valve with red hand wheel with pressure restricting feature. Female N.P.T. inlet X male hose thread outlet. 175 lb. rated. Furnished with field setting chart. Fig. 04080 .................................. 1½'Sin 04085 ..................................2½' Size DOUBLE FEMALE REGULARLY FURNISHED: Cast brass valve with red hand wheel with pressure restricting feature. Female N.P.T. Inlet and outlet 175 lb. rated. Furnished with field setting chart. Fig. 04090 .................................. 1½°Size 04095 ................................... 2½"Size CAST BRASS CAP WITH CHAIN. CAST BRASS FLANGE WITH SET SCREW Fig Size CAP VARIATION: Fig.Size 0.0. 04615.....,. 1½"0 Luge ° 04711 ...... 1½ ' ..........3" () 4 ½" V 04825 .........2½' 04712 ......2½' ..........6¼' Threads: 0 N.S.T. 0 Other_______ DATE C Rough Chrome Plated 0— D Polished Chrome Plated ri OPTIONAL FINISHES: 0—B Polished Brass FIGURE NUMBER 10.04 VIC-FLANGE ADAPTER NOTES i The Style 744 (2 - 8/50 - 200 mm) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. 2 FireLock Flange adapter should not be used on FireLock fittings. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. a FireLock Flange adapters should not be used as anchor points for tie-rods across nonrestrainedjoints. Mating rubber faced flanges, valves, etc. require the use of a FireLock Flange washer. 4 Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type for effective sealing. 5 FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. o Flange Washers: FireLock Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic-Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal Flange Washer be inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Flange Washer should be used are: A When mating to a serrated flange: a standard flat flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the FireLock Flange adapter and the flange gasket. B When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the FireLock Flange adapter. c When mating a rubber faced flange: the Flange Washer is placed between the FireLock Flange adapters and the rubber faced flange. D When mating AWWA cast flanges to IPS flanges: the Flange Washer is placed between two FireLock Flanges. The hinge points must be oriented approximately 90° to each other. If one flange is not a FireLock Flange adapter (e.g. flanged valve), then a standard flat flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock Flange adapter. E When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 'I. F When mating to a Series 705-W Butterfly valve, Style 744 may only be used on one side of the connection. When ordering Flange Washers, always specify product style (Style 74 4) and size to assure proper Flange Washer is supplied. MATERIAL SPECIFICATIONS Flange Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Coating: Black enamel Optional: Hot dipped galvanized Bolts/Nuts: Supplied by installer Gasket: Grade "E" EPDM - Type A Vic-Plus Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Ap- proved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated work- ing pressure using the Grade "E" Type A Vic-Plus Gasket System, requiring no field lubrication for most installation conditions. Standard gasket approved for dry pipe systems to -40°F (-40°c). eased on 'typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F (-18°C) and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Style 744 FireLock® Flange Adapter i 10.05 VICTAULICe IS AN ISO 9001 CERTIFIED COMPANY No. 10-DR Drain Elbow PRODUCT DESCRIPTION No. 10-DR drain elbows are specifically designed for use on fire protection standpipes. The drain is drilled and tapped for a 1 (25 mm) NPT outlet. Constructed of durable ductile iron all sizes conform to the ratings of Style 77 couplings. No.10-DR elbows are supplied with grooves or shoulders. These fittings are not intended for use with Victaulic Plain End couplings. When connecting wafer or lug-type butterfly valves directly to Victaulic drain elbows with Style 741 or 743 Vic-Flange® adapters or Style 744 FireLock® Flange adapters, check disc clearance dimensions with the I.D. dimension of the fitting. See Victaulic Publication 10.01 for details. Dimensions Fitting Size Inches/millimeters Nominal Actual Outside Outside Approximate Diameter Diameter Weight Each Inches/mm Inches/mm C - E H P Lbsikg 21/2 2.875 3.75 2.75 1.68 5.2 65 73,0 95 70 43 2.4 3 3.500 4.25 2.75 2.10 5.3 80 88.9 108 70 53 2.4 4 4.500 5.00 - 2.75 2,60 8.8 100 114,3 127 70 66 4,0 6 6.625 6.50 2.75 3.65 18.7 150 168.3 165 70 93 8,5 DIMENSIONS 0 51 _ A. P — Hk—Tff —I CtoE f+— MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. This product shall be manufactured by Victaulic company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. a REGISTERED TRADEMARK OFVICTAUIJC - C COPYRIGHT 2004 VICTAUUC - PRINTED IN U.S.A. 1509 REV 0 Victaulic Company of America- Phone: 1-800-PIcK. VIC (1-800-742-5842). Fax:610-250-8817• e-mail:pickvic@victaulic.com Victaulic company orcanada - Phone: 905-884-7444• Fax: 905-884-9714- e-mail: viccanada@victaulic.com Victaulic Europe- Phone:32-9-381-1500 Fax: 32-9-380-4438- e-mail: viceuro00victaulic.be Victaulic America Latina- Phone: 610-559-3300- Fax: 610-559-3608- e-mail: vical@victaulic.com \/Tc_ts~u la c Victaulic Asia Pacific- Phone: 65-6235-3035- Fax: 55-6235-0535- e-mail: vicap@victaulic.com I ; I' 1O..21: VlCTAUUCe IS AN ISO 9201 CERTIFIED COMPANY No. 67 Vic®-End H End of Run Fitting PRODUCT DESCRIPTION The No. 67, Vice-End ii, End of Run Fitting is the fast, easy, economical way to end a branch line. The fitting installs easily with standard FireLock® couplings and allows direct head connection, sprigs or drops. Available in l'I4, 11/2, 2 and 21/2" (32 - 65 mm) sizes, the fittings can be supplied with 1/2 3/4, or 1" (15, 20 0125 mm) female threaded (NPT) outlet (BSPT option available). The 90" reducing outlet fitting is UL/ULC Listed and FM Approved for a maximum rated working pressure of 500 psi (3450 Wei). UYL UL See Victaulic Publication 10.01 for details. DIMENSIONS, PERFORMANCE SIZE Approx. Nominal Inches C to E Weight Each Equivalent mm Inches/mm Lbsikg Feet/meters of Pipe 1/4 X 1/2 NPT 2.38 1.4 2,8 32 X 15 NPT 61 0.6 0.9 2.38 1.4 2.8 X 3/4 NPT X 20 NPT 61 0.6 0.9 X 1 NPT 2.38 1.4 2.8 X 25 NPT 61 0.6 0,9 11/2 X 1/2 NPT 2.50 1.6 2.9 40 X 15 NPT 64 0,7 0,9 2.50 1.6 2.9 X NPT X 20 NPT 64 0.7 0,9 X 1 NPT 2.50 1.6 2.9 X 25 NPT 64 0.1 0.9 2 X 1/2 NPT 2.75 1.7 4.0 50 X 15 NPT 70 018 1.2 X 3/4 NPT 2.75 1.7 4.0 X 20 NPT 70 0.8 1,2 X 1 NPT 2.75 1.7 4.0 X 25 NPT 70 0,8 1.2 21/2 X 1/2 NPT 3.00 2.0 5.7 65 X 15 NPT 76 0.9 1.1 X 3/4 NPT 3.00 2.0 5.7 X 20 NPT 76 0.9 1,1 X 1 NPT 3.00 2.0 5.7 X 25 NPT 76 0,9 1.7 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12, painted Orange Enamel. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Galvanized - hot dipped. Outlet: NPT Optional: BSPT This product shall be manufactured by Victaullc or to Victaulic specifications. All products to be installed in accordance with current victaulic installation/assembly instructions. V'ictaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. e REGISTERED TRADEMARK OF VICTAUUC - C COPYRIGHT 2005 VICTAULIC - PRINTED IN U.S.A. - SKU NVCAS-6DCXSPW 3209 REV C United States- Phone: 1-800-PICK-vlc (1-800-742-5842). Fax:610-250-8817• e-mail: pickvic@vieaulic.com Canada- Phone: 905-884-7444• Fax: 905-884-9774- e-mail: viccanada@victaulic.com Europe. Phone: 32-9-381-1500- Fax: 32-9-380-4438 e-mail: viceuro@victaulic.be UK- Phone: 44(0)1438741100- Fax: 44(0)1438313883- e-rnail:viceuro@vict3ulic.be Central and South America- Phone: 610-559-3300- Fax: 610-559-3605- e-mail: vical@victaulic.com Australasia- Phone: 86-21-58855151- Fax: 86-21-58851298- e-mail: vicap@vieaulic.com /(tauIic 07.01 VICTAULIC" IS AN ISO 9051 CERTIFIED COMPANY Grooved End Fittings PRODUCT DESCRIPTION Victaulic offers a broad line of fittings in sizes through 48/1200 mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including malleable iron, ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided .. ,., grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange adapters, check disc clearance dimensions with I.D. dimension of fitting. Advanced Groove System - For 14 - 247350 - 600 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5. 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8'125 - 200 mm. AGS—Advanced Groove System Refer to Section 21.03 or contact Victaulic for details. ALTERNATE STYLES Extra Heavy EndSeal "ES" Fittings - EndSeal fittings are available in 2 - 12750 - 300 mm for use with "ES" grooved pipe and HP-70E5 EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic Stainless Steel fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. t ' H FOR ABRASION RESIS TANCE ONLY .- Hj~ pp~wm_--T FOR CORROSION ANDIOR ABRASION RESISTANCE S REGISTERED TRADEMARK OF V1CTAUUC - 0 COPYRIGHT 2005 VICTAUUC - PRINTED IN USA - SI(U #WCAS-6A6RW6 United States' Phone: 1-800-PICK-VIC (1-800-142-5842). Fax: 610-250-8811• e-mail: pickvic@victauilc.com Canada Phone: 905-884-1444' Fax: 905-884-9114• e-mail: viccanada@victaulic.com Europe' Phone: 32-9.381-1500' Fax: 32-9-380-4438• e-mil:viceuro@victaulic.be UK' Phone: 44(0)1438141100' Fax: 4.4(0)1438313883. e-mail: viceuro@victaulic.be Central and South America' Phone: 610-559-3300• Fax: 610-559-3608 e-mail: vical@victaulic.com Australasia' Phone: 86-21-54253300• Fax: 86-21-54253671• e-mail: vicap@victaulic.com 1449 REV K x4a t~auhlce 07.01 FLOW DATA (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/20 elbow is approximately one- half the resistance of a 450 elbow. Values of mid-sizes can be interpolated. Size Dimension - Feet!meters Size Dimension - Feet/meters Elbows Tees Elbows Tees Actual Actual 900 Elbows 450 Elbows 900 Elbows 450 Elbows - No. 10 No. 100 No. 11 No. 110 No. 10 No. 100 No. 11 No. 110 Nominal Outside Nominal Outside Size Dia. Std. 11I2 D Long Std. 11!2 D Long Size Dia. Std. 112 0 Long 11'Radius Std. 1/2 D Long lnJrnm lnlmm Radius Radius Radius Radius Branch Run lnimm lnimm Radius Radius Radius Branch Run 1 1.315 1.7 - 0.8 - 4.2 1.7 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 25 33.7 0.5 - 0.2 - 1.3 0.5 200 1 219.1 4.0 3.0 2.0 1.2 10.1 1 4.0 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 50 60.3 1.1 0.8 0.5 1 0.3 2.6 1.1 250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 3.000 4.3 - 2.1 - 10.8 4.3 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 76.1 mm 76.1 1.3 - 0.7 - 3.3 1.3 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 14 14.000 # 15.8 # 11.0 70.0 23.0 80 88.9 1 1.5 1.2 0.8 0.5 4.0 1.5 350 355.6 # 4.8 # 3.4 21.3 7.0 4.250 6.4 - 3.2 - 15.3 6.4 16 16.000 # 18.0 # 13.0 80.0 27.0 108.0 mm 108.0 2.0 - 0.9 - 4.7 2.0 400 406.4 # 5.5 # 4.0 24.4 8.2 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 18 18.000 # 20.0 # 14.0 90.0 30.0 100 114.3 2.1 1.5 1.0 0.6 4.9 2.1 450 457.0 I 6.1 I 4.3 27.4 9.1 5.250 8.1 - 4.1 - 20.0 8.1 20 20.000 # 22.5 # 16.0 100.0 33 13:3.0 mm 133.0 2.5 - 1.2 - 6.2 2.5 800 508.0 1 6.9 I 4.9 30.5 10.1 5.500 8.5 - 4.2 - 21.0 8.5 24 24.000 # 27.0 # 19.0 120.0 40.0 139.7 mm 139.7 2.6 - 1.3 - 6.4 2.6 600 610.0 I 8.2 I 5.8 36.6 12.2 5 5.563 8.5 - 4.2 - 21.0 8.5 26 26.000 # 28.0 1 20.5 130.0 43.0 125 141.3 2.6 - 1.3 - 6.4 2.6 650 660.4 I 8.5 I 6.3 39.6 13.1 6.250 9.4 - 4.9 - 25.0 9.6 30 30.000 1 34.0 1 24.0 150.0 50.0 159.0 mm 159.0 2.9 - 1.5 - 7.6 2.9 750 762.0 I 10.4 I 7.3 45.7 15.2 6.500 9.6 -. 5.0 - 25.0 10.0 36 36.000 1 40.5 1 28.5 180.0 60.0 65.1 mm 165.1 2.9 - 1.5 - 7.6 3.0 900 914,0 1 12.3 I 8.7 54.9 18.3 6 6.625 10.0 7.5 5.0 3.0 25.0 10 42 42.000 1 47.0 # 33.0 166 7a0 150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 1050 1067.0 1 14.3 I 10.1 64.0 21.3 I tie now oata listea is oasea upon me pressure crop or .neuuie *u pipe. # Contact Victaulic for details. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 40/20 - 100 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5 - 6/125 -150 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type [or 5, Gr. B 8 -12'/200 - 300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type [or S, Gr. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B- 16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-i 6.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. 2 Grooved End Fittings '• r O7.Oi DIMENSIONS Fittings (Ductile Iron) rCt0E1 Cto" Cto. 42 'i _ to .-CtoE No. 10 No. 11 No 12 No. 13 No. 20 No. 35 Size 90 Elbow 45 Elbow 221/2 Elbow 111/4* Elbow Tee Cross (8w) Actual Nominal Outside C to E Aprx. C to E Aprx. C to Aprx. C to E Approx. C to Aprx. C to Aprx. Size Dia. Inches Wgt. Ea. Inches Wgt. Es. Inches Wgt Es. Inches Wgt. Es. Inches Wgt. Es. Inches Wgt. Es. lnfmm InJmm mm Lbsjkg mm LbsJkg mm Lbsikg mm LbsJkg mm Lbsikg mm Lbsikg 3/4 1.050 2.25 0.5 1.50 0.5 1.63 sw - 1.38 sw - 2.25 0.6 2.25 0.9 20 26.9 57 0.2 38 0.2 41 - 35 - 57 0.3 57 0.4 1 1.315 2.25 0.6 1.75 0.6 3.25 @ 0.6 1.38 sw 0.3 2.25 1.0 2.25 1.3 25 33.7 57 0.3 44 0.3 83 0.3 35 0.1 57 0.5 57 0.6 11/4 1.660 2.75 1.0 1.75 0.9 1.75 0.8 1.38 sw 0.5 2.75 1.5 2.75 2.1 32 42.4 70 0.5 44 0.4 44 0.4 35 0.2 70 0.7 1.0 1.0 11/2 1.900 2.75 1.2 1.75 0.9 1.75 0.8 1.38 sw 0.5 2.75 2.0 2.75 2.5 40 48.3 70 1 0.5 44 0.4 44 0.4 35 0.2 70 0.9 70 1.1 2 2.375 3.25 1.8 2.00 1.3 3.75 @ 1.4 1.38 1.0 3.25 3.0 3.25 3.8 50 60.3 83 0.8 51 0.6 1 95 0.6 35 0.5 83 1.4 83 1.7 21/2 2.875 3.75 3.2 2.25 2.2 4.00W 2.3 1.50 1.1 3.75 4.3 3.75 6.1 65 73.0 95 1.5 57 1.0 102 1.0 38 0.5 95 2.0 95 2.8 3.000 3.75 3.7 2.25 3.4 - - - - 3.75 5.2 - - 76.1 mm 76.1 95 1.7 57 1.5 - - - - 95 2.4 - - 3 3.500 4.25 4.5 2.50 3.1 4.50W 3.1 1.50 2.1 4.25 6.8 4.25 10.5 80 88.9 108 2.0 64 1.4 114 1.4 38 1.0 108 3.0 108 4.8 31/2 4.000 4.50 5.6 2.75 4.3 2.50 sw 4.0 1.75 SW 2.7 4.50 sw 7.9 4.50 11.5 90 101.6 114 2.5 70 2.0 64 1.8 44 1.2 114 3.6 114 5.2 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 5.00 11.9 5.00 15T- 100 114.3 127 3.2 76 2.6 73 2.5 44 1.6 127 5.4 127 7.2 4.250 5.00 11.0 3.00 5.6 - - - - 5.00 15.5 - - 108.0 mm 108.0 127 5.0 76 2.5 - - - - 127 7.0 - - 4 /2 5.000 5.25 sw 10.0 3.13 sw 6.0 3.50 6.6 1.88 SW 4.2 5.25 sw 15.0 5.25 18.5 120 127.0 133 4.5 79 2.7 89 3.0 48 1.9 133 6.8 133 1 8.4 5 5.563 5.50 11.7 3.25 8.3 2.88 sw 7.8 2.00 sw 5.0 5.50 17.8 5.50 20.0 125 141.3 140 5.3 83 3.8 73 3.5 51 2.2 140 8.1 140 9.1 5.250 5.50 11.7 3.25 8.3 - - - 5.50 13.8 - - 133.0 mm 133.0 140 5.3 83 3.8 - - - - 140 8.1 - - 5.500 5.50 11.7 3.25 8.3 - - - - 5.50 17.8 - - 139.7 mm 139.7 140 5.3 83 3.8 - - - - 140 8.1 - - 6 6.625 6.50 17.2 3.50 10.8 6.25W 12.2 2.00 7.0 6.50 25.7 6.50 28.0 150 168.3 165 7.8 89 4.9 159 5.5 51 3.2 165 1.7 165 12.7 6.250 6.50 18.6 3.50 10.8 - - - - 6.50 27.1 - - 159.0 mm 159.0 165 8.4 89 4.9 - - - - 165 12.3 - - 165.1 mm 6.500 6.50 15.5 3.50 9.8 3.13 11.4 2.00 7.4 6.50 22.0 6.50 28.0 165.1 165 7.0 89 4.4 79 5.2 51 3.4 165 10.0 165 12.7 8 8.625 7.75 29.9 4.25 20.4 7.75W 20.0 2.00 10.1 7.75 47.6 7.75 48.0 200 219.1 197 13.6 108 9.3 197 9.1 51 4.6 197 21.6 197 21.8 10 10.750 9.00 63.3 4.75 37.5 4.38 sw 30.0 2.13 sw 11.8 9.00 99.0 9.00 121.5 250 273.0 229 28.7 121 17.0 111 13.6 54 5.3 229 44.9 229 55.1 12 12.750 10.00 74.0 5.25 66.7 4.88 sw 40.0 2.255w 29.3 10.00 133.0 10.00 110.0 300 323.9 254 33.6 133 30.3 124 18.1 57 13.3 254 60.3 254 49.9 14 # t 14.000 14.00 136.0 5.75 65.0 5.00 sw 46.0 3.50 sw 32.0 11.00 145.0 11.00 198.0 350 355.6 355.6 61.7 146 29.5 127 20.9 89 14.5 279 65.8 279 89.8 16#t 16.000 16.00 171.0 6.63 88.0 5.00 sw 58.0 4.005w 42.0 12.00 186.0 12.00 250.0 400 406.4 406.4 77.6 168 39.9 127 26.3 102 19.1 305 84.4 305 113.4 18#t 18.000 18.00 228.0 7.46 108.0 5.505w 65.0 4.50 sw 53.2 14.00 256.0 15.50 350.0 450 457.0 457.2 103.4 189 50.0 140 29.5 114 24.1 356 116.1 394 158.8 20 # t 20.000 20.00 298.0 8.28 138.0 6.00 sw 78.6 5.00 sw 65.0 15.00 339.0 17.25 452.0 500 508.0 508.0 135.2 210 62.6 152 36.0 127 29.5 381 153.8 438 205.0 24#t 24.000 24.00 438.0 9.94 221.0 7.00 sw 140.0 6.00 sw 60.0 17.00 473.0 20.00 795.0 550 610.0 609.6 198.7 252 100.2 178 63.5 152 27.2 432 214.5 508 360.6 14 -24 A GS For AGS fitting Information see publication 2005 350 600 Fittings to these dimensions are only offered outside the U.S. w Gooseneck design, end-to-end dimension (sw) Segmentally welded steel # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. Grooved End Fillings Page 1 ot I tq ""D /F/ow / iyco Fire (Control / Products iAaster.. ARE SPRINKLER PiPt & FiniNGs SUBMITTAL SHEET TWO FIRE PRoDucls 451 North Cannon Avenue Lansdale, Pennsylvania 19446 wwwtyco-fire.coni TECHNICAL SEatacts TEL: (800) 381-9312 FAX: (800) 7915500 E-MAIL. techseWtycofp.corn No. 19-1.5 TD*15 5/16/2006 http://www.tyco-fire.com/TFP_gif/19-015-901—I.gif ,, r rage 1 01 1 Infr.nihirfinn hUll U5lU•IljIi Tyco Fire Producs (TFP) BlazeMasterl CPVC pipe and fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems.. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of We art additives. TFP BiazeMaster CPVC products are easier to mstall than traditional steel pipe systems, and at Tti:l fl4g.i ieii111utd1 uaia Sizes: V' - 3' Maximum Working Pressure: 175 psi Approvals: UL FM, CLJL, NSF, Dade County, LPCB, MEA, and the City 01 Los Angeles Note; See curienl TFP BbzeMaster lnstaiatidn frisVuct1s arl Tediniai Manual, for exact iismgpprovat ki*xTnatin fl% rwe the same time, they provide superior heat resistance and sttenglh as compared to traditional CPVC and PVC piping materials used in the plumbing trace. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inssfls for durabiIit Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings, Manufacture Source: U.S.A. Material: Pipe: ASTM F442, SOP 13.5 Fittings: ASTM F438 (Soh, 40) and ASTM, F439 (Sch. 50) Color: Orange tioln.PiprSiza Avg. O.fl.Inches Aq. 1.10 10des Wt.LbsJFt. WLNO filled Pi*LbsJFt. Ft. af Pipe pertlft Wt,pUttths. ____ 1.050 0,874 0.17 043 7875 1413 11316 1.101 026 0.67 5040 1320 1.660 1.394 0.42 1.07 2635 1191 ,/;:__ 1900 1.598 055 140 2205 1136 7 2.375 2.003 0.86 2.20 1260 1063 2 '1;" 2.875 2.423 1.26 3.22 1215 1531 31500 2.952 1.87 - 4,79 720 1344 Fittings 450 Elbow NO TIM .Reducing 900 Elbow 900 Elbow Tv MMI#Lx -,~ Pan No. Size Soli. TO wt. 80050 W 40 "It 0.08 lb. 80051 r 40 W 0.11 lb. 80052 1 '/ 40 W 0.20 lb. 80053 1'i' 80 0,31 lb. 80054 2' 80 W' 0.56 lb. 80055 21/j' 1 80 /. 0.89 lb. 80056 3 80 1'. 1.191b. Part No. it Size Sch. i/o wt. lb. 11 2 80032 * x Y.' 1 40 '/ 'V' 0.16 Part No. Size Sch, Tb WI. 80025 4' 40 I" 0.09 lb. 80026 1" 40 '1' 0,14 lb, 80027 17" 40 'h' 0.21 lb. 80028 If 80 1 11,4*1 0.40 lb. 80029 2' 80 11k' 0.79 lb. 80030 272" 1 80 1//' 1.14 lb. 80031 Y 80 1/c° 1.82, lb. Tee Reducing Cross Cross Part No. SizeI Sth, Tb Wt. 60000 dii" 40 0.11 lb. 80001 1" 40 'ft' 0.19 W. 80002 114' 40 0.26 lb. 80003 1/? 80 1" 0.51 lb. 80004 2' 80 1W' 0,90 1b. fl1Y'Ac I. O'I. I ;in I 1P.."I I Kark Part No. size Scti. 1/0 wt. tb 1 40 1!I-c'I- 2 80015 1 x i' 0.28 Part No. Size Sch.1 i/O I WI 80009 W 40 'I 0.13 lb. 30010 1" 40 0.23 lb. 80011 1W' 40 0.34 lb. 800i2 1W 80 1'/' 0.61 lb. 80013 2' 80 V1' 1.00 lb. 4 I >'l.' I an I 14-- I I 01 1k http://www.tyco-fire.comiTFP_gifll9_0 1 5_90 1_2.gif 5/16/2006 1 of 2 Tol-Brace Seismic Calculations Project LA COSTA GLEN - REC. Lifeguard Fire Protection lnc VULCU Address: 2605 Temple Heights Dr.,Ste a brand of t1UECO" 7819 RUSH ROSE DRIVE Oceanside,CA 92056 C16-758459 CRLSBAD, CA 92008 p(760)806-9997 f(760)806-4813 Fi t U Job # Calculations based on 1999 NFPA Pamphlet #13 ' t Brace Information Tolco Brace Components Tolco Component Fig. Number Adjusted Load Maximum Spacing 2V-0" (6.468m) Fig. 1000 Clamp 567 lbs. (257 Kg.) Length of Brace 7 '- 0 "(2.2m) Fig. 910 Threaded Swivel 1745 lbs. (792 Kg.) Bracing Material 1" Sch. 40 *calculation Based on CONCENTRIC Loading *please Note: These calculations are for Tolco components only. Angle from Vertical 600 Mm. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11mm) Assembly Detail LIR Value 200 Maximum Horizontal Load 3061 lbs. (1388Kg.) TOLCO FIG. 910 SWIVEL AY BRACE FITTING TOLCO FIG. 1000 FAST CLAMP Fastener Information STEEL PIPE LATERAL BRACE Fastener Orientation NFPATypeF Type Through-Bolt Diameter 3/81n.(10mm) Length 3m.(76mm) 60° Mm. From Vertical Detail #3222 Brace Identification on Plans LATERAL Maximum Load 831 lbs. (377Kg.) Orientation of Brace Lateral Load Information Size and Type of Pipe Total Length Total Calculated Load 1"(25mm)Schedule 40 Pipe 35 ft. (10.7m) 36 lbs. (17Kg.) 23'2"(63mm) Schedule 7 Pipe 21 ft. (6.4m) 54 lbs.(25Kg.) IW'(38mm)ThreadableThinwall Pipe 147.3ft.(44.9m) 224 lbs.(102Kg.) Percentageadded for Fittings and Sprinklers 15% 47 lbs. (21.321<g.) Total Adjusted Load of allpipewithinZoneofInfluence 360 lbs. (164Kg.) (Tol-Brace Version 51.49) Tol-Brace Seismic Calculations For LA COSTA GLEN - REC. c:j LLtJJD 7819 RUSH ROSE DRIVE a brand offlICO Job # 2of2 Brace Identification Brace Type (Per NFPA#13) Spacing of Brace Orientation of Brace Bracing Material Length of Brace Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener LATERAL NFPA Type F 21 Ft.(6m) Lateral 1 Sch.40 7Ft. (2m) 200 600 318in. (10mm) In. Through-Bolt 3m. (76mm) In. Summary of Pipe within Zone of Influence 21/2 inch Sch. 7 11/2 inch Thrd. Thinwall 1 inch Sch. 40 Allowance for Heads and Fittings Conclusions 21 Feet (6m) 147.3 Feet (45m) 35 Feet (111 m) 0.15% Total Adjusted Load of Pipe in Zone of Influence 360 lbs.(163Kg.) Material Capacity 3060.5991574859 lbs.(1388Kg.) Fastener Capacity 831 Ibs.(377Kg.) Fig. 1000 Clamp 567 lbs.(257Kg.) Fig.910 Threaded Swivel 1745 lbs.(792Kg.) Structural Member: PRE-FAB ROOF TRUSS* Calculations prepared by JEREMIAH BALCH *The description of the Structural Member is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with To[-Brace 5.1 visit us at v.tolco.com LIFEGUARD FIRE :PROTECTION, INC;. Fire Protection Design &lnstállation AAA , •• January ii, 2006 Mt. Greg Ryan Carlsbad FfreDepattmeñt. 1635 Faraday Avenue Carlsbad, CA 92008 Fax (760) 602-8561 Re: La Costa Glen—Ph se VI Carlsbad, CA Greg, This letter isto's1nu Larize .oth. mee.tiiig fr j:e1i today(0iI1i/O6)"regarding the .1ir. sprinkler. for the above-mentioned project.-This-:roject consists of six buildings Commons, Recreational and buildings E, F, G and II The purpose of our meeting was for the E, F, G and H buildings Be buildings will require a modred NFPA 13 fire sprinkler system The modification& are listed below. Design criteria to be LightBazaxd (. 10t.l500). in. all attic; 10f6rve heads i. the corridors and 10 for 4 heads in dwellmg areas All areas will require 100 GPM outside hose demand. . Steel pipe is to be used throughout the buildings with the exception of the dwelling areas were CPVC'is allowed. .. S. Protection is not required in space between the ceiling and the floor above (i.e. second and third floors) Protection is required in the attic space Residential quick response fire sprinkler heads are allowed in the dwelling areas Installation and design shall be per cut sheet requirements Fire sprinkler heads shall be installed in.- all closets, bathrooms, exterior balcomes/closets and mechanical closets In mechanical closets the use of sidewall sprinklers below the unit/duct would be recommended, Manual dry standpipe(s) with wall mounted FDC might be required The standpipefFDC locations will be coordinated with the Carlsbad Fire Department and owner If you feel any of these items are in error please notify me at your earliest convenience Thanks again for your time and help. Respectfully, . . . . . •• .' •.: D 4an n Apran Lifeguard Fire Protection,. Inc. ' . •• • . 2605 TEMPLE HEIGHTS DRIVE A SUITE F A OCEANSIDE, CA 91056 A 7;60/8'06-9997A FAX 760/806-48.13 ES-A-3000SS Series 3000SS Double Check Detector Assemblies Sizes: 21/2' - 12" (65 - 300mm) FIRE Series 3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free through the waterway. The double check detector assembly consists of two independently opeiating, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons),..doubie check including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Can-check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable seat. There shall be no brass or bronze parts used within the cam-check valve assembly The check valve seats shall be of molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shailcon- sist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have a single access cover, two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly. Noryl® Flange dimension in accordance with AWWA Class D. NoryP is registered trademark of General Electric Company. Features Patented Cam-Check Assembly valve provides low head loss Short lay length is ideally suited for retrofit installations Stainless Steel body is half the weight of competitive designs reducing installation and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of maintenance No special tools required for servicing Compact construction allows for smaller vaults and enclosures Furnished with W x 3/0 bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use o Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG -less shutoff valves OSY - UL/FM outside stem and yoke resilient seated gate valves ROSY FxG - flanged Inlet gate connection and grooved outlet gate connection GxF - grooved Inlet gate connection and fiangedOutlet gate connec- tion "OSY GxG -grooved ink t connection and grooved Outl8t4te connection CFM -cubic feèti minute GPM - gallons per minute meter Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications In U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please Contact Ames Technical Service. Mite reserves the right to change or modify product design, cosptruction, specifications, or materials without prior notice and without incurring any obligation make such changes and modifications on Ames products previously or subsequently sold. 1. www.amesfirewater.com Pressure - Temperature Temperature Range: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 175ps1 (12.06 bar) Capacity Flow curves as tested by Underwriters Laboratory per UL 1469, 1996. * Rated flow UL Tested We 83 69 55 41 28 14 6GF111 N••m•••u••• •••• .......... uu• .._._.._. UOEEENNMWE~m P. I A Standards A\MNA C510-92, UL 1469 Approvals For 12 approvals consult factory. ®. ØSIp.4 4 App,oved us 1048 (sIzes 2u/2 - 10°, (OSY Only) OSY Only) ______I u••u i• — —.--- I_ I. .__. 'hI1wv [liIi1Tfl OMMMMMMMMIEM I.. MMMMMMMMMINME1 MMMMMMMMMIEN21 rn••••u •• i .-. .. ------- : -• -------- .-• ------ • SIZE (ON)II1I3!69Iu1!K nsal8uIJ NET WEIGHT in. mm A in. mm C (OSY) in. mm D in. mm C in. mm L in. mm P in. mm wlGates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16/8 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/2 114 10 250 22 559 141/2 368 240 109 73 33 6 150 481/2 1232 1 301/e 765 51/2 140 15 381 271/2 699 151/2 394 390 177 120 54 8 200 521/2 1334 1 373/4 959 1 6/4 171 15 381 291/2 749 1 18'/2 464 572 259 180 82 10 250 551/2 1410 1 453/4 1162 1 8 200 15 381 291/2 749 1 191/2 495 774 351 190 86 12 300 571/2 1461 1 531/8 1349 1 91/2 241 15 381 291/2 749 1 21 533 1044 474 220 100 A IMPOWNO.- Inquire with governing authorities for local installation requirements. _____ A M E S uEi]9OO1 FIRE &WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERT1RED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-3000SS 0513 ©Ames Co. 2005