Loading...
HomeMy WebLinkAbout2235 PALOMAR AIRPORT RD; ; FA040039; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA040039 2235 PALOMAR Job Address: AIRPORT RD Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/17/2004 Approved: 6/1/2004 Issued: 6/1/2004 Inspector: Project Title: CARLSBAD SELF STORAGE FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: SWIFT COMMUNIATIONS INC. 4365 MEADE AV SAN DIEGO, CA 619-572-8504 Fees ($) Add'I Fees ($) Total ($) Balance ($) 90 0 90 0 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT 11 I & - i —11--ic IL 1 1 STORAG E the Srti ci &JI SJcnipy 2235 Palomar Airport Road Carlsbad, CA 92009 (760) 602-0909 Fire Alarm Upgrade Building "D" System Submittal I Y OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or appro,ye the violation of any law. flyLiL. Date_______ SCHEDULE F3DEPT. NSPEcTIONS May 11, 2004 LONE (760 Owner: Carlo Development Contact: Jim Schfer 619-977- P-- Table of Contents Drawings Single Line Building Diagrams System Detail Diagrams Battery Calculations Product Cut Sheets - CSFM listings Manufacture Description Firelite Control Panel Firelite Modules Firelite Smoke Detector Firelite Battery Wheeloc Bell Belden 4 conductor Part # CSFM Listing MS9200-UD 7165-0075-158 MMF-300 7300-0075-185 CRF-300 SD-355 7272-0075-194 BSL-1075 MB-G10-24R 7135-0785-113 9571 & 9574 7161-0060-005 To building D MS 9200 CONTROL PANEL F!I1 Wheeloc 24vdc Bell FRI Firelite CR-300 control module © Firelite SD-355T Smoke/ thermal detector © Firelite BG-12 pullstation Firelite MM-300 Monitor Module Elevator Shaft 3rd Floor 2nd Floor 1st Floor Elevator Recall System Primary Elevator Return (1st Floor) Relay 7 - Detectors 1,6 Secondary Elevator Return (2nd Floor) Relay 11 - Detectors 2,3,4 Power Shunt Cicuit Relay 8 - Detector 5 Elevator Mechanical Room To panel located in telcom room bldg "A" Wheeloc 24vdc Bell Firelite CR-300 control module Firelite SD-355 Smoke Detector Firelite MM-300 Monitor Module MS-9200UD Battery Calculation **Since the current draws listed here can be edited, the user is fully responsible for verifying these calculations. ** [E7nt7i!~ _qjj!y!LO,be made in the Yellow cell locations Regulated Load in Standby Page 1 Device Type Number of Devices - - Current (Amps) - - Total Current (Amps) Main Circuit Board 1 X 0.3 0.3 ACM-8RF X 0.03 = 0 ACM-I 6ATF ACM-32AF X 0.04 = 0 AEM-I 6ATF AEM-32AF X 0.002 = 0 AFM-1 6ATF AFM-32AF X 0.04 = 0 AFM-16AF 0.025 = 0 LDM-32F X 0.04 = 0 LDM-E32F X 0.002 = 0 LCD-40F X 0.064 0 4XTMF X 0.005 = 0 4-Wire Smoke Detectors X 1 = 0 Power Supervision Relays X 0.025 0 CP350 X 0.0003 = 0 SD350 X 0.0003 0 SD350T 5 X 0.0003 0.0015 H350 X 0.0003 = 0 H350R 1 X 0.0003 = 0.0003 L)350P X 0.0003 = 0 D350RP X 0.0003 = 0 MMF-300 2 X 0.0004 = 0.0008 MMF-300-10 X 0.0035 = 0 MDF-300 X 0.00075 = 0 MMF-301 X 0000375 = 0 MMF-302 X 0.00027 = 0 MMF-3026 X 0.002 = 0 BG-I2LX X 0.0002 = 0 CMF-300 X 0.00039 = 0 CMF-300-6 X 0.00225 0 CRF-300 3 X 0.00027 = 0.00081 CRF-300-6 X 0.00145 = 0 1300 X 0.0004 = 0 B50IBH & B501 BHT (see note 3) X 0.001 = 0 B224RB Relay Base X 0.0005 = 0 B224B1 Isolator Base X 0.00045 0 Current Draw from TB3 (nonalarm) 0 SUM COLUMN FOR STANDBY LOAD 0.30341 +=AMPS Notes Refer to the Device Compatibility Document for standby current Must use compatible listed Power Supervision Relay Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. Current limitations of TB3 and T134 circuits is 2.5 amps per NAC output and 0.5 amps per aux. power output Total current draw listed cannot exceed 6.0 amps MS-9200UD Battery Calculation **Since the current draws listed here can be edited, the user is fully responsible for verifying these calculations. ** Regulated Load in ALARM Page 2 Device Type Number of Devices - - Current (Amps) - - Total Current (Amps) Main Circuit Board I X 0.168 = 0.168 ACM-8RF 0 X 0.158 = 0 ACM-16ATF ACM-32AF 0 X 0.056 = 0 AEM-1 6ATF AEM-32AF 0 X 0.018 = 0 AFM-1 6ATF AFM-32AF 0 X 0.056 = 0 AFM-I6AF 0 X 0.065 0 LDM-32F 0 X 0.056 = 0 LDM-E32F 0 X 0.018 = 0 LCD-40F A X 0.064 = 0 4XTMF 0 X 0.011 = 0 4-Wire Smoke Detectors 0 X 0 Power Supervision Relays 0 X 0.025 = 0 Addressable Devices (Max draw all dvcs) 11 X 0.4 4.4 NAC#1 X 0.4 = 0 NAC#2 X = 0 NAC#3 X = 0 NAC#4 X = 0 Current Draw from T133 (nonalarm) = = 0 SUM COLUMN FOR ALARM LOAD = 4.568 JAMPS notes 1 )Current limitations for NAC circuits T133 & TB 4 is 2.5 amps per circuit 2)ACM 8RF current based on a single module 3) Annuciator current based on all LED's lit 4)LDM-32F current with all LED's on MMF 302 current limited to 90mA in alarm Total alarm current cannot exceed 6.0 amps MS-9200UD Battery Calculation **Since the current draws listed here can be edited, the user is fully responsible for verifying these calculations. ** Entries only to be made in the Yellow cell locations Calculation in Total Sheet Page 3 Use the total standby and alarm load currents calculated in tables A-2A and A-213 for the following battery calculations Standby Load Required Standby Time in Hours Current (Amps) (24 or 60 Hrs.) 030341 X 24 = 728184 Alarm Load - Required Alarm Time in Hours Current (Amps) (5 minutes = 0.084) 4568 X 0083333333 = 0380666667 Add Standby and Alarm Load for Required Ampere Hour Battery 7.662506667 Multiply by the Derating Factor of 1.2 Total Ampere Hours Required = 9.195008 Battery Check The MS 9200UD can charge this size battery The batteries can be stored in the cabinet Current Draw Check MS 9200UD without XRM-24 transformer The required output current is within the panel's limitations MS 9200UD with XRM-24 transformer The required output current is within the panel's limitations June 17, 2003 DF-52293 • Al-2501 (8 Flre•ule®Alarms www.firelite.com GENERAL The Fire-Lite MS-9200UD is a compact, cost-effective, intelli- gent addressable fire alarm control panel with a capacity of 198 addressable Fire-Lite devices on one Signaling Line Cir- cuit (SLC) and a built-in 14.4K Baud modem for remote site upload/download or remote monitoring. The Signaling Line Circuit (SLC) loop supports up to 99 addressable detectors including photoelectric, photoelectric with heat, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also sup- ports up to 99 addressable modules including monitor (two- wire detector, normally open devices), dual-monitor func- tions (two monitor circuits from one module, two addresses used), control (for Notification Appliance Circuits), and relay (two Form-C) modules. The panel uses surface-mount tech- nology and is designed for ease of installation, programming, and maintenance. It features the latest in advanced fire pro- tection technology, including maintenance alert and auto- matic detector test functions. SPECIAL FEATURES.- - Built-in 14.4K Baud modem. Selectable strobe synchronization per NAC. Remote site upload/download. Four Class B or two Class A NAC circuits. FEATURES SLC Loop: SLC can be configured for NFPA Style 4, 6, or 7 opera- tion. SLC supports up to 198 addressable devices (99 detec- tors and 99 monitor, control, or relay modules), including the new addressable dual-monitor module, heat detec- tors, and duct detector. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.25 mm2). Requires twisted, shielded wire (3,000 ft./914.4 m untwisted, unshielded wire). Notification Appliance Circuits (NACs): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAG. 6.0 amps total NAC power with XRM-24. Advanced Fire Technology: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. Programming and Software: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 key- board or PC via PK-Plus Windows® utility. MS-9200UD Intelligent Addressable FACP with Built-In 14.4K Baud Modem Section: Addressable California State Fire &Marshal 7165-0075:208 LISTED S624 IEL' Remote site upload/download capability. Two-level user-programmable passwords. Custom English labels (per point) may be manually en- tered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. User Interface: Built-in 14.4K Baud modem (DACT). Remote Acknowledge, Silence, Reset and Drill via addres- sable monitor modules, ACS Series annunciators or LCD- 80F remote annunciator. ElA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS Series annunciators. EIA-485 supporting up to 32 LCD-80F annunciators. Maintenance alert warns when smoke detector dust ac- cumulation is excessive. Automatic device type-code verification. cont'd pg. 3 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all ____________ ISO 9001 specific applications or anticipate all requirements. All specifications are sub- ject to change without notice. For more information, contact Fire-Lite Alarms, I One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, INGINEIRING & MAMIMRING Made in the U.S.A. Toll-Free FAX: (877) 699-4105. DF-52293 . 06117103 - Pagel of 4 24 VDC ri E!A-485 INTERFACE (DIM-485) built into the motherboard (four wires) LCD-80F Up to 6,000 ft. (1825.8 m) between each LCD-80F in the EIA-485 loop, and between each LCD-80F and the FACP 24 VDC E!A-485 in ACS mode (two wires) ANNUNCIATORS AFM-LED, LDM, EIA-232 ACS/ACM INTERFACE (PIM-24) built into the motherboard NOTE: System can use either the printer OR the LCD-80F They cannot be used simultaneously. WIRING REQUIREMENTS Optional REVERSE Y BOX T OUTPUT (4XTMF) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8RF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES SMOKE DETECTORS S0350, S0350T, CP350, SD355, SD355T, CP355 HEAT DETECTORS H350, H350R, H355, H355R [uMJLi] DUCT DETECTORS D350P. D350RP MONITOR MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 1300 MINI MONITOR MMF-301 .. ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6 The SLC requires use of a specific wire type to ensure proper circuit operation. It is recommended that all SLC wiring be twisted-pair shielded to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.75 mm2) and no larger than 12 AWG (3.25 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Distance Typical Wire Size Requirements in Feet (m) Twisted-pair, shielded 10,000 feet 12 AWG (325 mm2): Belden 9583, Genesis 4410, (3.048 m) Signal 98230, WPW D999. Tsted-pair, shielded 8.000 feet 14 AWG (2.00 mm2): Belden 9581, Genesis 4408, (2,438 m) Signal 98430, WPW D995. Twisted-pair, shielded 4,875 feet 16 AWG (1.30 mm2): Belden 9575, Genesis 4406 (1,486 m) and 4606, Signal 98630, WPW D991. Twisted-pair, shielded 3,225 feet 18 AWG (0.75 mm2): Belden 9574, Genesis 4402 (983 m) and 4602, Signal 98300, WPW D975. Unwisted, unshielded 3,000 feet (915 m) 12— 18 AWG (3.25-0.75 mm2). PULL STATION BG-1 2LX 52293d1.wn,t Page 2 of 4 - DF-52293 06/17/03 CABINET SPECIFICATIONS Door: 18.67" (47.43 cm) high x 15.78" (40.08 cm) wide x 1.08' (2.74 cm) deep. Backbox: 18.50' (47.0 cm) high x 15.50' (39.37 cm) wide x 4.37" (11.1 cm) deep. Trim Ring (FC-TR): 21.62" (54.92 cm) high x 18.62" (47.3 cm) wide. PRODUCT LINE INFORMATION MS-9200UD: 198-point addressable Fire Alarm Control Panel. Includes 80-character LCD display, single printed circuit board, and cabinet. ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PK-Plus programming software for Windows®-based PC computer (cable not included). DP-9200UD: Dress panel for MS-9200UD. FC-TR: Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two PS-12250 batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two PS-12250 batteries. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH. CHG-120F or CHG- 75 required for charging greater than 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. P5-12180: Battery, 12 volt, 18.0 AH, (two required). PS-12250: Battery, 12 volt, 25 AH, (two required; requires CHG-75). PS-12550: Battery, 12 volt, 55 AH, (two required; requires CHG-75). PRT/PK-CABLE: Cable printer/personal computer interface cable. Windows® is a registered trademark of Microsoft Corporation. COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP350/CP355: Addressable low-profile ionization smoke detector. SD350/5D355: Addressable low-profile photoelectric smoke detector. SD350T/SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H350/H355: Fast-response, low-profile heat detector. H350R1H355R: Fast-response, low-profile heat detector with rate-of-rise option. D350P: Photoelectric duct smoke detector. D35ORP: Photoelectric duct smoke detector with relayoption. MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10. 16 cm) box. Includes plastic cover plate and end-of-line resistor. Module maybe configured for either a Style B (Class B) or Style D (Class A) lDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module forone Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts Page 4 of 4 - DF.52293 . 06/17/03 directly to a 4.0" (10.16 cm) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm) box, surface mount using the SMB500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount upto six modules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTES: 1) Compatible with legacy Fire-Lite 300 Series de- vices. Please consult factory for further information on all the 300 series devices: CP300, SD300, SD300T, M300, M301, M302, C304, and BG-IOLX. 2) "A" suffix should be included only when ordering ULC listed units (e.g., SD350A, MMF-300A). 3) For more information on Compatible Addressable Devices for use with the MS-9200U0, see the following data sheets (document numbers): 5D3501SD350T (DF-52 149), CP350 (DF-52158), MMF-300 SerieslMDF-300 (DF-52121), BG-I2LX (DF-52013), MMF-300-10 (DF-52347), MMF-302-6 (OF- 52356), CMF-300-6 (DF-52365), and CRF-300-6 (DF-52374). COMPATIBLE ANNUNCIATORS EIA-485 interface: Built into the motherboard. AFM-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 with expandable (AFM-X Se- ries) and non-expandable (AFM Series) configurations to meet a variety of applications. ACS/ACM Annunciator Series: Allows annunciation of loop modules and detectors. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80- character, backlit LCD-type fire annunciators capable of dis- playing English-language text. Up to 32 LCD-80F annuncia- tors may be connected to the ElA-485 terminal mode serial interface on the MS-9200UD motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9200UD, see the following data sheets (document numbers) AFM/AFM-X Series (DF-51465), ACM- 8RF (OF-S 1555), ACSIACM Series (OF-52378), LDM Series (DF-51384), LCD-80F (DF-52185). AGENCY LISTINGS AND APPROVALS See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the ba- sic MS9200UD control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or list- ing may be in process. Consult factory for latest listing sta- tus. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7165-0075:158 Page 1 of I Control Unit (Non High-Rise) Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: *Brian Reynolds (203) 484-1200 FAX (203) 484-7309 Models MS-9200, MS-9200E and AMS-9200 fire alarm control units. Local, *central station, auxiliary, remote station, proprietary service. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-9200 Control Unit RTM-8F Relay Module ZDM-16F Annunciator Driver PIM-24 Printer/PC Interface Module LCD-40, LCD-40L Remote LCD Annunciator DIM-485 Display Interface module XRM-24 Transformer *UDACTF Digital Alarm Communicator Transmitter INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. These control units can generate a distinctive three-pulse Temporal Pattern Fire alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to listee's Installation Instructions Manual for details. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev. 2-14-2003KK - This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation. - criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager September 28, 2001 DF-52130 E-350 (a FirelfferALarms www.firelite.com GENERAL CMF-300 Control Module (Replaces C304) The CMF-300 Addressable Control Module provides Fire-Lite Alarm's MS-9200 and MS-9600 intelligent control panels a supervised Class B (Style Y) or Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF to be activated, either manu- ally or through panel programming, on a select (zone or area of coverage) basis. CRF-300 Relay Module (Replaces C304 configured as a relay) The CRF-300 Addressable Relay Module provides the MS-9200 and MS-9600 systems with two isolated sets of Form-C dry-contact outputs for activating a variety of auxil- iary devices, such as fans, dampers, door holders, con- trol equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel program- ming, on a select basis. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The CMF module requires power (for horns, strobes, etc.). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). The CMF may be used to switch 24-volt NAC power. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) entry of address. APPLICATIONS The CMF is used to switch 24 VDC audible/visual power. The CRF may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc. CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-99 on the MS-9200 and 01-159 on the MS-9600). The CMF is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF provides two Form-C dry contacts that switch together. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. CMF and CRF Series Addressable Control and Relay Modules Section: Addressable Devices S I < > U@ L Approved RVIC 7300-0075:185 CONTROL U - :t. CMF-300 and CRF-300 Module OPERATION Each CMF or CRF uses one of 99 (MS-9200) or 159 (MS- 9600) possible module addresses on a SLC loop. It re- sponds to regular polls from the control panel and reports its type and status, including the open/normal/short sta- tus of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The CMF supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the CMF will discon- nect the supervision and connect the external power sup- ply in the proper polarity across the load device. The dis- connection of the supervision provides a positive indica- tion to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a mod- ule and a sensor address. This document is not intended to be used for installation purposes. We try to keep I our product information up-to-date and accurate. We cannot cover all specifici ISO 9001 1 applications or anticipate all requirements. All specifications are subject to change I without notice. For more information, contact Fire-Lite Alarms, One Fire-Life Place. I ;b dl = I Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699I (PJINfUflNC & MMVMC1URIN 4105, FAX l3ack:(888) 388-3299. Made in the U.S.A. DF-52130 - Page 1 of 2 SPECIFICATIONS FOR CMF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 390 pA (LED flashing). External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4 (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4 (101.6 mm) square x 2.125° (53.975 mm) deep box. SPECIFICATIONS FOR CRF Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5' (114.3 mm) high x 4' (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125 (53.975 mm) deep box. PRODUCT LINE INFORMATION CMF-300 Intelligent Addressable Control Module. CRF-300 Intelligent Addressable Relay Module. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier - required by UL for separating power-limited and non-power lim- ited wiring in the same junction box as CMF-300. RELAY CONTACT RATINGS for both CMF and CRF models Load Description Application Maximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Inductive (L/R = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 125 VAC 0.5 A 5724rate.thl 151 ril MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant ISOLATED QUADRANT 4(101.6mm) square x 2.125° (53.975 mm) deep box Page 2of 2 - DF-52130 April 23, 2001 DF52121 E325 Fire-LITerALarms MMF-300 Series/MDF-300 Addressable Monitor Modules www.11relite.com Section: Addressable Devices GENERAL Four different monitor modules are available for Fire-Lite Alarm's MS-9200 and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as con- ventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 (Replaces M300) — The MMF-300 Moni- tor Module is a standard-sized module (typically mounts to a 4 [101.6 mm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- vices. MMF-301 (Replaces M301) —The MMF-301 isaMin- iature Monitor Module (a mere 1.3° (33.02 mm) H x 2.75° (69.85 mm) W x 0.5' (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF- 301 to be mounted in a single-gang box behind the device it is monitoring. MMF-302 (Replaces M302) — The MMF-302 Inter- face Module is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 (New) - The MDF-300 Dual Monitor Module is a standard-sized module (typically mounts to a 4° [101.6 mm] square box) that supervises two Class B (Style B) cir- cuits of dry-contact input devices. MMF-300 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 —99 (MS-9200) and 01 -159 (MS-9600) entry of address. LED flashes green during normal operation and latches on steady red to indicate alarm. The MMF-300 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire Class A or Class B fault- tolerant Initiating Device Circuit (IDC) for normally-open-con- tact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style 0 (Class D) Initiating Device Circuit. A 471< ohm End-of-Line Resistor (provided) 7300-0075:185 p1 ' F I r 5 . JJ ti 4 MMF-300, MMF-302 and MDF-300 terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. MMF-300 Operation — Each MMF-300 uses one of 99 (MS-9200) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (114.3 mm) high x 4 (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. IThis document is not intended to be used for installation purposes. We try to keep ourl Iproduct information up-to-date and accurate. We Cannot cover all specific applica- tions or anticipate all requirements. All Specifications are subject to change without I Inotice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, I i i Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-410, FAX ENGIN1111ING & MANUFACTURING IBack:(888) 388-3299. Made in the U.S.A. DF-52121 — Page lot3 PRODUCT LINE INFORMATION MMF-300 Monitor Module. MMF-301 Mini Monitor Module. MMF-302 Two-Wire Detector Monitor Module. MDF-300 Dual Monitor Module. SMB500 Optional Surface-Mount Backbox. MOUNTING DIAGRAMS for standard-sized modules I j C>-4ef-1- I kt~ — _11~1 . I ,:- cwl' ; r " W__0 " >dt * I dresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed security devices. The module has a single panel-controlled red LED indicator. MDF-300 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. MDF-300 Operation - Each MDF-300 uses two of 99 (MS-9200) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MDF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (114.3 mm) high x 4(101.6mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 electrical box. INSTALLATION MMF-300, MMF-302 and MDF-300 modules mount directly to a standard 4" (101.6 mm) square, 2.125' (53.975 mm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wir- ing only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. ARCH ITEcTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all Fire-Lite Alarms products are available from Fire-Lite Alarms. DF-52121 - Page 3of 3 MMF-301 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the MS-9200. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99). The MMF-301 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The MMF-301 can be used to replace M301 module in existing systems. 1415 0 1 ADDRESS i L 0 11 2 :L E9 i 4 5 TENS ONES MMF.301 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301 Operation - Each MMF-301 uses one of 159 (MS-9600 only) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Ini- tiating Device Circuit (IDC). MMF-301 Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 pA maximum EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.30 (33.02 mm) high x 2.75 (69.85 mm) wide x 0.5" (12.70 mm) deep. Wire length: 6° (152.4 mm) minimum. Page 2of 3 - DF-52121 MMF-302 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source (resettable). High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99). LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intel- ligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. MMF-302 Applications - Use the MMF-302 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or 0 (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style 0 ap- plication. MMF-302 Operation - Each MMF-302 uses one of 159 (MS-9600 only) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Ini- tiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VAMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (114.3 mm) high x 40 (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. MDF-300 DUAL MONITOR MODULE Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 159 on the MS-9600. LED flashes green during normal operation and latches on steady red to indicate alarm. The MDF-300 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independant two-wire fault-tolerant Initiating Device Circuits (lDCs) at two separate, consecutive ad- CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:185 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 Fax (203) 484-7309 DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and *MMF..302..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. *Rev. 1-24-2003 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager May 3, 2001 DF-52149 E-150 (8 FIreLrre® iarms www.firelite.com GENERAL The SD350 and SD350T Addressable, low-profile plug-in Photoelectric Detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire-Lite's MS-9200 and MS-9600 Addressable Fire Alarm Control Panels. The SD350T adds thermal sensors that will alarm at a fixed tem- perature of 135° F. Since this detector is addressable, it will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (Part No. RA400Z). FEATURES SLC Loop 2-wire loop connection. Unit uses base for wiring. Addressing Addressable by device. Direct Decade 01-99 (MS-9200) and 01-159 (MS-9600) entry of address Architecture Unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. 5D350(A)/SD35OT(A) Addressable Photoelectric Detectors Section: Addressable Devices (OT:::; 7272-0075:194 S0350 Other System Features Fully coated circuit boards and superior AF/transient pro- tection. Removable cover and insect-resistant screen for simple • 94-VO plastic flammability rating. field cleaning. • Low standby current. Operation Withstands air velocities up to 1,500 feet-per-minute with- out triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshhold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" or 4" octagonal box, or 4" square electrical box (using a plaster ring - included). Options Remote LED output connection (Part No. RA400Z). APPLICATIONS Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are of- ten better than photoelectric detectors at sensing fast, flam- ing fires. CONSTRUCTION These detectors are constructed of LEXAN® in an off-white color. The 5D350(T) plug-in low-profile smoke detectors are designed to commercial standards and offer an attractive ap- pearance. This document Is not intended to be used for installation purposes. We try to keep our1 product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without I _____________________ notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, I i rl ;b dl =1 Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX ENGINifIlINt & MANUMtIURING Back:(888) 388-3299. Made in the U.S.A. INSTALLATION The SD350(T) Plug-In Detectors use a detatchable mount- ing base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4 (10.16 cm) square box with plaster ring. 4" (10.16 cm) octagonal box. 3.5 (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring °T- taps' or branches are permitted for Style 4 (Class B) wiring. OPERATION Each SD350(T) uses one of 99 possible addresses on the MS-9200 Signaling Line Circuit (SLC) or up to 318 (159 on each loop) on the MS-9600 SLC. It responds to regular polls from the system and reports its type and status. The 5D350(T) Addressable Photoelectric Sensor TM unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 1,500 feet-per-minute without sending an alarm level sig- nal. Because of the unipolar chamber, the SD350(T) is ap- proximately two times more responsive than most photoelec- tric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have their sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to an MS-9200 or MS- 9600 addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 and MS- 9600 for record keeping. SPECIFICATIONS Voltage range: 15 - 32 VDC (peak). Standby current: 300 pA © 24 VDC. LED current: 6.5 mA © 24 VDC (latched "ON"). Air velocity: 1,500 ft./min. (7.6 mlsec.) maximum. Diameter: 5.0 inches (12.7 cm), 6.2 inches (155 mm) installed in B350LP Base. Height: 1.7 inches (43 mm) installed in B350LP Base. Weight: 3.6 oz. (102 g). Operating Temperature Range: 00 to 49° C (320 to 120°F) 5D350. Operating Temperature Range: 00 to 38° C (32° to 100°F) SD35OT. Temperature: 0° - 49°C (32° - 120°F). Relative humidity: 10% - 93%, non-condensing. Page 2 of 2 - DF-52149 PRODUCT LINE INFORMATION SD350(A) Addressable Photoelectric Detector (13350LP base included). (A) model has ULC listing. SD350T(A) Same as above with thermal element (B350LP base included). (A) model has ULC listing. RA400Z Remote LED. Mounts to a single-gang box. B350LP Plug-in detector base (included). Diameter: 6.1(155mm). Mounting: 4"(lo2 mm) square box with or without plastic ring, 4" octagon box, 3 1/2" octagon box or single gang box. All mounting boxes have a minimum depth of 1.5" (38 mm). B224RB Plug-in System Sensor relay detector base. Diameter: 6.2" (157 mm). Mounting: 4" (102 mm) square box with or without plastic ring, 4" octagon box, 3 1/2° octagon box. All mounting boxes have a minimum depth of 1.5" (38 mm). B501 BH Plug-in System Sensor sounder detector base. Diameter: 6.0"(153 mm). Mounting: 4" (102 mm) square box with or without plastic ring. Mounting box has a minimum depth of 1.5" (38 mm). CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:194 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Fire-Lite Alarms Inc., One Fire-Lite Place, Northford, CT 06472 Contact: Brian Reynolds (203) 484-1200 Fax (203) 484-7309 DESIGN: Models SD350, SD350T, SD355*, SD355T* and AD355* photoelectric type smoke detectors. Model SD350T and SD355T* has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. *All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. Rev. 11-03-2002 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:195 Page 1 of I CATEGORY: Heat Detector LISTEE DESIGN: RATING INSTALLATION: MARKING: APPROVAL: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds (203) 484-1200 Fax (203) 484-7309 Models H350, *H355, and *H355HT fixed temperature heat detectors. Models H350R and *H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. *H350 *H355, and *H355HT 135° F fixed temperature *H350R and *H355R 15° F rate-of-rise *H355HT 190° F fixed temperature In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating and UL label. Listed as heat detectors for use with separately listed compatible fire alarm control units. Rev. 12-22-2002 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SERIES MB t ; RSSP REMOTE PLATE REMOTE PLATE with SBL-2 Built-in trimplate makes semi-flush mounting simpler and less expensive. Screw terminals permit fast in-out field wiring of #12 to 18AWG wire. Polarized for DC supervision of NAC circuits. Operates on filtered or unfiltered DC. For combined audible (bell) and visual signaling, convenient retrofit plate assemblies are available with Multi-Candela or Single candela strobes (Refer to Fire Alarm Products Catalog for Series RSSP Sync/Non-Sync Strobes specifications and technical information). wheelock . . -- - A ZZ 1T.TT. LT; !% ® h! (JJ Heping Pccp1e Thke Action SERIES MB MOTOR BELLS Description Wheelock's Series MB Motor Bells provide a better engineered motor bell for fire and life safety alarm systems. The Wheelock Series MB Bells include higher ciBA, low current draw, built-in trimplate for semi-flush mounting, low frequency aluminum shells, and low RFI noise. The motor for Series MB Bells is a durable, high torque permanent magnet motor selected for its high performance and long life. These DC vibrating Series MB Motor Bells are offered in 6" and 10" shell sizes in both 12 and 24 VDC models. Series RSSP Sync/Non-Sync retrofit plates are used in conjunction with the Series MB Motor Bell when combination appliances are required. The Series RSSP retrofit plates are available with either Multi-Candela or single candela strobes and easily mount to a 4" square or Wheelock SBL-2 backbox. All Series RSSP strobe appliances meet or exceed the requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities), ADA (Americans with Disabilities Act) and UL Standard 1971 (Signaling Devices for the Hearing Impaired). The Series RSSP retrofit plates may be synchronized when installed with the Wheelock Series SM, DSM, Sync Modules or the PS-1 2/24-8 Power Supply with Wheelock's patented sync protocol. Wheelock's synchronized strobes offer an easy way to comply with ADA requirements concerning photo-sensitive epilepsy. Features Approvals include: UL Standard 464, Factory Mutual (FM), California State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP). Meets OSHA 29 Part 1910.165. High sound output with low current draw. Low frequency aluminum shells for better audibility through walls, doors and other structures. 6" and 10" shell sizes in 12 or 24 VDC models. Integral RFI suppression to minimize included noise on the NAC circuit. Mounting options for surface, semi-flush, outdoor, and concealed conduit installation. Ordering Information Model Number Order Code Shell Size Input voltage (VDC) Input Current dBA © 10 Ft. Mounting Options MB-G6-12-R 3942 6" 12 0.060 92 D,E,J,K,N,R,S,Z MB-G6-24-R 3941 6" 24 0.030 M13-G10-12-R 3944 1 10" 12 0.060 MB-G10-24-R 1 3943 1 10" 24 1 0.030 Copyright 2002 Wheelock, Inc. Al! rights reserved. NOTES: Typical dBA at 10 feet is measured in an anechoic chamber. For bells all 12 VDC models are UL rated for 9.0 to 15.6 VDC and all 24 VDC models for 18.0 to 31 .0 VDC. Architects and The alarm appliances shall be Wheelock Series MB vibrating Motor Bells or approved equal. They shall be UL Standard 464 Listed for Fire Protective Service. Shells shall be aluminum in 6' or 10" diameter. Sound output at 10 feet shall be 92 dBA. The bells shall incorporate a permanent magnet motor and suppression circuitry to minimize RFI. They shall include a built-in trimplate for semi-flush mounting to a standard 4" square backbox, or surface mounting to Wheelock's indoor BB backbox or outdoor WBB backbox. For bell strobe applications, retrofit plates Wheelock Series RSSP with Multi-Candela or Single Candela strobes shall be used. All bell models shall be polarized for line supervision and shall have screw terminals for in-outfield wiring of #12 to #18 AWG wire. Operating voltage shall be nominal 24 VDC or 12 VDC. Finish on all models shall be red enamel. Model Number Order Code Nominal Voltage (VDC) Strobe Candela Average Current (AMPS) at listed VDC —Mounting Options RSSP-24MCW-FR 9402 24 15/30/75/110 .050/.081/.133/.161 D,E,Z RSSP-241575W-FR 7793 24 15 (75 on-axis) .065 DE,Z RSSP-121575W-FR 1 7798 12 15 (75 on-axis) .170 D,E,Z SYNC MODULES! POWER SUPPLY Model Number Order Code Input Voltage (VDC) Average Current (AMPS) @ 24 VDC I Mounting Options" SM-12124-R' 6369 24 .026 i W OSM-12/24-111' 6374 24 .035 W PS-12124-8'"" 8114 120 VAC - Average Current per actual Wheelock Production Testing at listed VDC. For Rated Average and Peak current across UL regulated voltage range for both Filtered DC and Unfiltered VRMS, see Installation Instructions Refer to Data Sheet S7000 for Mounting Options #SM Sync Module is rated for 3.0 amperes © 24 voc. ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected OSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. ###Refer to Data Sheet S9001 or Installation Instructions P83862 for PS.12124-8 Power Supply. Wiring Fig. I Bell Models Fig. 2 Retrofit Strobe AUDIBLE STROBE Plate Models (RSSP) -i 1+ I V- FROM PRECEDING - TONEXS TO NEXT FROM APPLIANCE OR FACP + APPLIANCE + OR EOLR APPLIANCE _____________ ___________ PRECEDING } OR END-OF-LINE APPLIANCE { RESISTOR OR FACP (EOLR) FROM - TO NEST - PRECEDING STROBE OR STROBE OR + + FACP Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintaine d and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, c o u n t y , province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, al l appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLA11ON INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 800-631-2148 Canada 800-397-5777 E-Mail: Info@wheelockinc.com http://www.wheelockinc.com MADE IN THE USA 3 YEAR WARRANTY Member Distributed By: 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588 S1500 Rev. 06/02 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: USTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: 7135-0785:113 Page 1 of 1 Audible Devices Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 Model MB series bells and Model MBS series bell/strobes. Models MB are suitable for outdoor use when used with Model WBB backbox. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Rev. 12-08-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test I , results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager For more information please call 1-800-Belden 1 See Put-ups and Colors Detailed Specifications& Technical Data 9571 Non-Paired - Fire Alarm Cable Description: 18 AWG Solid bare copper conductors, PVC insulation, PVC jacket. PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Conductors . 2 Total Number of Conductors 2 AWG 18 Stranding Solid Conductor Material BC - Bare Copper INSULATION: Insulation Material PVC - Polyvinyl Chloride Nom. Insulation Wall Thickness .017 in. OVERALL CABLING: Overall Cabling Lay Length . . 1.75 in. = Overall Cabling Twists/ft. 6.8 :rall Cabling Color Code Chart: mber Color Black Red OUTER SHIELD: Outer Shield Material OUTER JACKET: Outer Jacket Material Outer Jacket Nominal Wall Thickness OVERALL NOMINAL DIAMETER: Overall Nominal Diameter MECHANICAL CHARACTERISTICS: Operating Temperature Range UL Temperature Rating Unshielded PVC - Polyvinyl Chloride .037 in. .228 in. 40°CTo+105°C 105°C (UL AWM Style 2464),105-C (UL AWMStyle 1424) Detailed Specifications &: Technical Data 9571 Non-Paired - Fire Alarm Cable Bulk Cable Weight 26 lbs/1000 ft. Max. Recommended Pulling Tension 50 lbs. Min. Bend Radius (Install) 2.25 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification MPR,FPLR NEC Articles 760 CEC/C(UL) Specification PAS 105 AWM Specification UL Style 2464 (300 V 105°C), UL Style 1424 (300 V 105°C) Other Specification California State Fire Marshall: FLAME TEST: UL Flame Test UL 1666 Vertical Shaft C(UL) Flame Test FT4: Other Flame Test UL 70, 0.00, BTU Flame Test (comparable to IEEE383 Flame Test) PLENUM/NON-PLENUM: Plenum (YIN) N ELECTRICAL CHARACTERISTICS: Nom. Inductance .169 1iHlft Nom. Capacitance Conductor to Conductor @1 KHz 22pF/ft Nom. Conductor DC Resistance @20 Deg. C 6.3 Ohms/I000 ft Max. Operating Voltage - UL 300 V RMS (UL AWM Style 2464), 300 V RMS (UL AWM Style 1424) Other Maximum Continuous Currents 5.2 Amps per conductor @ 25°C PITT-11Pq AND CflI.flUS Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 9571 002U1000 2 #18 PVC PVC U1000 28 RED 9571 002U500 2#I8PVC PVC U500 14.5 RED Revision Number: I Revision Date: 01-30-2004 © 2003 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ('Belden") makes every reasonable effort to ensure their accu r a c y a t t h e t i m e o f t h i s p u b l i c a t i o n , information and specifications described herein are subject to error or omission and to chan g e w i t h o u t n o t i c e , a n d t h e l i s t i n g o f s u c h information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no represen t a t i o n s o r w a r r a n t i e s , w h e t h e r e x p r e s s , statutory or implied. In no event will Belden be liable for any damages (including consequent i a l , i n d i r e c t , i n c i d e n t a l , s p e c i a l , p u n i t i v e , o r exemplary damages) whatsoever, even if Belden has been advised of the possibility of su c h d a m a g e s , w h e t h e r i n a n a c t i o n u n d e r c o n t r a c t , negligence or any other theory, arising out of or in connection with the use, or inability to use, t h e i n f o r m a t i o n o r s p e c i f i c a t i o n s d e s c r i b e d herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Detailed Scificaioni & Technical Data 9578 Non-Paired - Fire Alarm Cable Outer Jacket Nominal Wall Thickness .037 in. OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .263 in. MECHANICAL CHARACTERISTICS: Operating Temperature Range -40°C To +105°C UL Temperature Rating 105°C (UL AWM Style 2464)1 1050C (UL AWM Style 1424) Bulk Cable Weighty I..... . ... 46.5 lbsl1000 ft. Max. Recommended Pulling Tension 99 lbs. Mm. Bend Radius (Install) 2.7 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification MPR, FPLR NEC Articles 760... CEC/C(UL) Specification FAS105 AWM Specification UL Style 2464 (300 V 1050C), UL Style 1424 (300 V 105°C) Other Specification California State Fire Marshall FLAME TEST: C(UL) Flame Test FF4 Other Flame Test .. UL 70,000 BTU Flame Test (comparable to IEEE383 Flame Test) PLENUM/NON-PLENUM: Plenum (YIN) ELECTRICAL CHARACTERISTICS: Nom. Inductance Nom. Capacitance Conductor to Conductor ® 1 KHz Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz Nom. Conductor DC Resistance @ 20 Deg. C Nominal Outer Shield DC Resistance @ 20 Deg. C Max. Operating Voltage - UL Other Maximum Continuous Currents N .169jHJft 43 pF/ft 79.2pF/ft 6.4 Ohms/1000 ft 11.7 Ohms/1000ft 300 V.RMS (UL AWM Style 2464), 300 V RMS (UL AWM Style 1424) 3.2 Amps per conductor @ 25°C Pt IT-TIPS ANfl CflLflRS Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 95780021000 4#18 PVC SHLD 1000 51 RED C PVC 9578 002U500 4 #18 PVC SHLD U500 25.5 RED PVC C = CRATE REEL PUT-UP. P,qnp 2 0(3 Data lied Specifications & Technical Data 9578 Non-Paired - Fire Alarm Cable Revision Number: I Revision Date: 01-30-2004 © 2003 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the tim e o f t h i s p u b l i c a t i o n , information and specifications described herein are subject to error or omission and to change without notice, and the listing of su c h information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whe t h e r e x p r e s s , statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidenta l , s p e c i a l , p u n i t i v e , o r exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under c o n t r a c t , negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications d e s c r i b e d herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. 5 04 09:20a Elsa Jones 619-640-3964 p.1 TO I 4365 Meade Ave, San Diego, CA 92116 (619)640-3959 Fax: (619)640-3964 To: b~ From: Fax: 7c?- Pages: Phone: Date: S 12; Re: CC: 0 Urgent For Review 0 Please Comment 0 Please Reply 0 Please Recycle S Comments: %4. <: 'c. Elevator Shaft ----------------------------------------------------------------------------- H Elevator Recall System Primary Elevator Return (1 St Floor) Relay 7 - Detectors 1,6 Secondary Elevator Return (2nd Floor) Relay 11 - Detectors 23,4 Power Shunt Cicuit Relay 8- Detector 5 C o I-) ......... W System Sensor U Horn/Strobe 24vdc 0) R Firelite CR-300 control module * Firelite SD-355 Smoke Detector in LIII Firelite MM-300 Monitor Module EOLj B j- Floor El 3rd evator Lobby B_j 2nd Floor Elevator Lobby 40 41 -----------------------------B ---- ----------- [~ Elevator Lobby Bldg nD Bldg D Flow Valve Tamper Elevator Mechanical Room . [B ........................................................................................4 e] ...... SLC-8 Circuit -.. NAC#I L_J Circuit To panel located in telcom room bldg "A" Fire Alarm Diagram 4365 Meae Ave Carlsbad Self Storage Sari Diego, CA 92116 61 q-640-3959 512€ - FSCUNO 041, G NO REV I Budding C 1:1 I 20F4 F? i!1 1. , •'ir Maj 20 04 04:07p Elsa Jones 619-640-3964 P.1 4365 Meade Ave, San Diego, CA 92116 (619) 640-3959 Fax: (619) 640-3964 To: (re5 (f(fL From: RE- 'i Fax: 7DO 60- 356( Pages: Phone: Date: Re: CC 0 Urgent 0 For Review JPlease Comment 0 Please Reply 0 Please Recycle Comments: Lk çfY1 r f0&.: Cref'y, pLa o 's ( r D e jec elo k L.e I AY4 - TLQ cL- v-k' o-\k c- (10 AR C . hA.VZ fl cv-c...T 0\ ev j •t) L-..Qc •. -'.,"- A LL ' Cc'"'" •v%4 .11 IQ -_ Vvi - S?? -E&SOL( Ma 21 04 11:11a Elsa Jones 619-640-3964 P.1 "lVc Co?i.I.ect i The Abilit Th Cc h 4365 Meade Ave, San Diego, CA 92116 (619) 640-3959 Fax: (619) 640-3964 To: From: Fax: o- 86I Pages: LO Phone: Date: Re: CC: 0 Urgent ,("For Review 0 Please Comment 0 Please Reply El Please Recycle Comments: S pee / rLb LJe. L/I rci's/ Ctr spr. ?k&y C' possIe1 A /e45e ti sb 4- V. ~j jo P'r -r -S This cu drop calculations in three Formal Load Ceriterinf Is accepted by, and the results Ihe respective Point to Point M thod Isbad CIRCUIT IS WITHIP LIMITS LIMITS 2Il200 idjng 0 inimum uev,ce Voltage 16 18=7.77 1 16=4.89 I 14=3.07 112=1.98 10=1.24 I j Total Circuit Current 0.370 Wire Ohms __ 15-14Awg = Solid Conductors12-10 Awy = Stranded Conductors - _I -- _Gauge Per 1000 Notes: I I I Distance from source to 151 device 330 18 7.77 Wire resistance is doubled in the calculations for two wires (Positive and Negative) Wire Gauge for balance of circuit 18 7.77 The voltage calculated to the last device in any method must not be lower then Enter current in amps. Distance - the manufactures listed minimum operating voltage (IE: rated operating voltage 20-32 VDC. .150 = 150 ma from Voltage Ailernate Calculations Device I Device previous At Drop from Percent End of Line Method Load Centering "-thod Number I Current device Device source Drop Totals Voltage Totals Voltage Device 1 0.010 330 22.10 1.897 7.91% Current I Distance Drop Current 1 Distance Drop Device 2 0.090 20 2.009 8.37% 0.370 1.667Dev 580 3.335 0.370 580 Device 0.090 10 21.95 2.051 8.55% End of Line Voltage - 22.33Dev 20.67 End of Line Voltage Device 0.090 120 21.61 2.387 9.95% Percent Drop 6.95%Dev 13.90% Percent Drop Device 0.090 100 21.47 2.527 10.53% END 21.47 2.527 1 - 10.53% Device Manufacturer System Sensor END 21.47 2.527 10.53% Current Current END 21.47 2.527 10.53% _______________ @RatedEND _______ @Raled ______ _______ _______ _______ 21.47 2.527 10.53% Modei# Candela Voltage Model# Candela Voltage END 21.47 2.527 10.53% P1224MC 30 0.090 END 21.47 2.527 10.53% P122IMC 30 0.090 END 21.47 2.527 10.53% '1224MC 30 .0.090 END 21.47 2.527 10.53% iP1224MC 30 0.090 O 21.47 2.527 10.53% MDL - 0.010 END 21.47 2.527 10.53% O 21.47 2.527 10.53% END 21.47 2.527 10.53% O 21.47 2.527 10.53% FEN D 21.47 2.527 10.53% O 21.47 2.527 10.53% Totals 0.370 580 EndafLineVoltaoel 21.47 o 3rd floor Strobe/horn floor Strobe/horn ----02nd o 1st floor Strobe/horn Elev. Equip. Rm Strobe/horn Swill Ca,mun,cations Inc. Carlsbad Self Storage 465 Meade A Strobe Horn Design with Voltage Drop Calculations Ma 21 04 11:11a Elsa Jones 619-640-3964 p.3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7125-1209:222 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6674 FAX (630) 377-7245 DESIGN: Models S1224MC synchronized strobe lights (when used with MDL Sync module) with selectable candela. Units may be followed by the suffix SP Indicating marking of the word FUEGO', *or the suffix P indicating plain housing with no lettering, may be followed by letter W indicating color white, otherwise it is red. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VOCIFWR 12/24 VDC/FWR Selectable 15cd, 15/75cd 24 VDC/FWR Selectable 30cd, 75cd, or 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired application when used with separately listed compatible lire alarm control units. Suitable for indoor use, wall mount only. Refer to listee's Installation Instruction Manual for details. Rev. 02-24-04 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification or any claims. This listing is not an endorsement or - • recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: FEBRUARY 24, 2004 Listing Expires June 30, 2004 Authorized By: DIANEK. AREND, Senior Deputy Program Manager Models Available St:obet Red White S1224MC S1224MCW S1224MCP S1224MCPW S1224MCK S1224MCSP Horn/Strobes Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP Horns Red White H12/24 H12/24W H12/24K MaV 21 04 11:12a Elsa Jones 819-640-3964 P.4 Product Overview Operates on either 12V or 24V SpectrAlert Selectable Ot.tput Horns, Strobes, and Horn/Strobes offer enhanced Ion. Widest range of candela options: tures that include the widest range of candela options available and the capability to 12V: 15 and 15/75 candela recognize and self-adjust for either 12 or 24 volt operation. With an overall feature 24'i(: 15, 15/75, 30. 75. 110 candela set that combines performance, installation ease, flexibility, and a consistent. aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name. Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClicklm Syiichronizablo with MDL SyncCircuitTM module Meets (JL1971. NFPA72, and ADA signaling requirements Al! strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent hash bulb voltage over the range of candela selections. The benefit to the customer Is a high quality strobe device. 0 @ USIED cs540V6025ts1954 25515 C554557025513751 ssu MEA 5ppVovd (125.1209:222 "' 12202•( 12,35.2209:223 3014153 175.02-1 Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The select- able candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixod-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert sel-ctable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClick'M feature. Such abor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and sell-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. MaV 21 04 11:12a Elsa Jones 619-640-3964 P.5 Engineering Specifications General SpecrrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4" x 4" x 11/2" back box or a single gang 2" x 4" x iix" back box using the universal mounting plate included with each SpcctrAkrt product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync-Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts, 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DCor full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash rube and associated lcnrcflcctor system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on hornt strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor SyncsCircuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlerr strobes at 11-la and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 4'1/i6" x 41l/., x 21/r" back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Weight, strobe and herr/strobe Operating, volt ElgEt ran1tr 8.8 oz. 12V: 8-17.5V; 24V: 16-33V Specifications Wak lest SpectrAlert horn/strobe and horn only work on "walk tests" with time dura- tions of 4 seconds or greater input; Terminals 12 to 18 AWG Dio'.eisoiis Strobe and horn/strobe with universal plate 5" x 5 /a" x 2/ts" Strobe and horn/strobe with small footprint plate 33/ 5/a" )C 2/sr," Horn with universal mounting plate 5" x 5/9' x Horn without mounting plate 2'/a6' * 5/16" x ',t'eient, ))o'i' c)ri 7.2 oz. r ouni iitg 4° x 4" x 11/2" or 2" x 4" x VY standard boxes Indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Mciiru'o humidity 95% as tested per UL464 Opere:ing Temperature Weatherproof (horn and horn/strobes) 32°F to 150°F (0°C to 66°C) (outdoor strobe only) -40°F to 158°F (-40°C to 70°C) IJLC Canadian Models -40°C to 66°C Vol; "ges 12 or 24VDC and FWR unfiltered Operating voltage. Iiangelt Iwith Syo°CircuIt module. MDL) 12V: 9-175V; 24V: 17-33V Note for Strobes: Do not exceed; 1) 16-33 or 8-17.5 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MDL Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line Impedance as requited by the fire alarm Control manufacturer U.S. Patent Numhers 5,593,569 5,914,665 6,049,446 Permissible Candela Settings CandIa opufating voltagu setting 12V 24V 15 OK Ott 15/75 OK OK 30 Ott 75 OK 110 OK Ma 21 04 11:12a Elsa Jones 619-640-3964 P'6 SpectrAlert Current Draw Srie Candela Setting FWR Operating Current-Strobe (mA RMS) DC Operating Current- Strobe (mA RMS) FWR Operating Current-Horn (mA RMS) DC Operating Curront-Hor,; ImA RMS) HOM Audibility (dBA 12V 24V 12V 24V 12V 24V 12V 24V S1224MC 15 112 64 127 59 Strobes 15/75 135 74 127 69 30 • 93 90 75 158 160 110 208 209 P1224MC Horn/Strobes 15 112 64 127 59 45.1 57.5 44.4 57 75 15/75 135 74 127. 69 45.7 57.5 44.4 57 75 30 93 90 57.5 57 75 75 158 160 57.5 57 75 110 208 209 57.5 57 75 H12/24 Horns 45.7 57.5 44.4 57 75 SpectrAlert Mounting and Operation Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the Temporal I Low Volume Electromechanical rear olltie product while watching the viewing window on the 3000 1* interrupted side of the reflector. I i High Volume Electromechanical 3000 Hz Interrupted Non-Temporal Low Volume Electromechanical 3000 Hz Interrupted High Volume Electromechanical 3000 Hz Interrupted Typical weatherproof mounting with universal plate ,—WBB Plate #8-36 x 1/2 Flat Head Screw (4 total) Gasket -' \_Condult Entrance slot \—Paper Liner For Plate Gasket DIP Switch Operation Factor,' DIP Switch OFF ON Default I Low I i i.i High r] Temporal ii I Non-Temporal 1c!,a_if?i] I _ r I I'I Electromech. II 3000Hz ] Base (rear) AQ1IQ.Qg Ma 21 04 11:12a Elsa Jones 819-640-3964 p.7 SpectrAlert Ordering Information Model Description P1224MC Selectable Output Horn/Strobe, 12/24 volt, red P1224MCW Selectable Output Horn/Strobe, 12/24 volt, white P1224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing P1224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, weatherproof P1224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, 'LJEGO housing S1224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe 12/24 volt, white S1224MCP Selectable Output Strobe, 12/24 volt, red, plain housing S1224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing S1224MCK Selectable Output Strobe, 12/24 volt, red, weatherproof 51224MC5P Selectable Output Strobe, 12/24 volt, red, "FUEGO' housing Notes Model Desceiptiost 1112/24 Horn, 12/24 volt, red 1112/24W Horn, 12/24 volt, white 1112/24K Horn, 12/24 volt, red, weatherproof C sissores MDL Sync .Circuit Module, red MDLW Sync-Circuit Module, white MDLA Sync-Circuit Module, red, Canadian model MDLWA SyncCircuit Module, white, Canadian model S-MP Small Footprint Mounting Plate, red, for single- gang hack boy S.MPW Small Footprint Mounting Plate, white, for single. gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Back Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box Agency Listings - Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products are designed for wall mount only. All weatherproof models gj use weatherproof bock box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horral strobes axe recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In Chine System Sensor - Far East System Senior - India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, 111. 60174 Fit: 905,812.0771 Fe: 86.29524.6259 Ps: 85.22.736.6580 Fe: 91.124.237.3118 Ph: 800/SENSOR2 Sy5em Sensor Europe System Sensor in Singapore System Senior - Australia System Sensor - Russia Fe: 630/377.6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 0ocunienss.on.Demand ifs: 44.1403.891921 Fx: 65.5273,2610 Fe: 613.54.281.172 Fe: 70.95.937.7983 800/736.7672 0 www.systemseasor.com 6 2004 System Snso,, The company reserves sire right to change product specltestions wittiest notice. AO5-0325.003'5/04•01200 Matl 21 04 11:12a Elsa Jones 619-640-3964 p.8 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: 7300-1209:179 Page 1 of 1 Misc. Devices/Control Unit Accessories System Sensor, 3825 Ohio Ave. St Charles IL 60504 Contact: Trish Linhart (630) 377-6674 Fax (630) 377-7245 Models MDL, MDLW sync modules. These modules are for use with listee's separately listed compatible horns and strobes. Refer to listee's data sheet for additional detailed product description and operational considerations. 12 or 24 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, product designation and UL label. Listed as sync modules for use with listee's separately listed compatible horns and strobes. Rev. 06-16.2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Matj 21 04 11:13a Elsa Jones 619-640-3964 p.S Models Available MDL (Red) MOIW (White) Canadian Models MDLA (Red) MDLWA (White) Product Overview Two wire operation from module Technology. The Sync-Circuit module synchronizes SpectrAlert' strobes at to the devices 1 Hz and horns at tempo al 3 over a single pair of wires. Patented module tech- Silences horns over a two wire loop nology also allows the silencing of horns on horn/strobe models over a pair of wires. Synchronizes strobes at i. Hz Synchronizes ltorns to temporal Application Flexibility. The Sync-Circuit module is designed to power and syn- 3 pattern chronize either two 3-am? circuits wired in Class B or one 3-amp circuit powered as Class A. Should more thin two zones require synchronization, Patented technology additional modules can be added by interconnecting the "slave" input and Allows slave module operation output terminals between modules. Generates synchronized temporal 3 Additional Capabilities, The Sync-Circuit module is also designed to generate tern- tone for Multi-Alert' and PA400 poral 3 tone for System Sensor's Multi-Alert and PA400 Mini-Alert sounders. horn products Existing installations can be upgraded to comply with NFPA 72. EngIneering Specifications Synchronization Circuit Module shall be a System Sensor Sync-Circuit Model listed to UL464 and shall be approved for fire protective service. The module shall synchronize SpecrrAlert strobes at 1 Hz and horns at temporal 3. Also, the module shall be capable of silencing the horns on horn/strobe models, while operating the strobes, over a single pair of wires. The module shall be ® capable of mounting to a 41 I'x 4"Asx 21/" back box and shall control two Style Y (class B) or one Syle Z (class A) circuit. The module shall be capable LISTED 55512 of multiple zone synchronization by connecting multiple modules together via a 54011 slave-infslave-out arrangement and re-synchronizing each other along the chain. JEA Note: The module shall not operate on a coded power supply approved 730O.12o9119 001.57*0 21.90M Ma 21 04 11:13a Elsa Jones 619-640-3964 p.10 ft General Soecifleations 5114' L N SW w back box Operating Specifications H ''U,g': Ulx-'.i ng '/ rt1i0 P rl 12 or 24 VOC and FWR unfiltered 9 to 17.5 VOC V) 17 to 33 VDC cinor :Ivr'-r,,n, nrc r.I c,- 32' to 120' F (0 to 49' C) on L-:r.(c 3 Amps/zone rc4'c: 5.598,139 5,850,178 Horns Silenced Over Two-Wire Circuit Any mix of Horn/Strobes or Strobe only devices is acceptable Horn control connects to Interruptible Power source MASTER MODULE SLAVE MODULE MCP SO I), coaa os I NOES ZOSE? HI ' 505050%. NOT jf NEXT MAcI ['To ECTRALERT 0. OP CC TRALERT DEVICE OR TO NEXT DEVICE OR :IEOL us Out 50%. MAC ('t)— 50%. MAC ,. ouri ZONE SINO 50505 TO NEXT NAD1 50515 SYNC ' ERROR I-) CTRAL SET I-I o NEXT SPECTRALERT )p. SUVE DEVICE OR SLAVE DEVICE OR ai 0*11 .-a'" TEJUMPLOOFO All SpectrAlert horns, horn/etrobee, and strobes will operate in sync. Temp 3 Coding of Multi-Alert and PA400 Sounders Strobes must be powered from non-coded supply OJ fl• HONE ZONEI CONTROL OU lO_ FACP NEXT — DEVICE OR - EOL MACI ZONE I ZONES out - - } NAC2 - - - ZONES SINE IN 5 5005 i TO NEXT DEVICE OR SLAVE StAVE FOIL Horn, will be Temporal TEMP. JUMPER ON eod.d and In .ynn, Ordering Information/Current Draw Model No. (Roll) Model No. White) voltage Average Current (mA) Peak Current (mA) in-rush Current (mA) DC I FWR DC FWR DC FWR MDL, MDLA (Canadian) 1MDLW, MDIWA (Canadian) 1 12 J 10 12 30 31 87 122 1 24 It 15 35 37 198 262 System Sensor Sales and Service System Senior Headquarters System Sensor Canada System Sensor In China System Sensor — Far East System Senior - Iflila 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85,22,191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Ix: 905.812.0771 Ix: 86.29.524.6259 Ix: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800/SNSOR2 System Senior Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 6301377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 Documents-on-Demand Fs: 44.1403.891921 Ix: 65.6273.2610 Ix: 613.54.281.172 Ix: 70.95.937.7953 800/735-767253 www.systemsensor.com 0 2004 System Sensor. The company reserves the viht to change NudeSt Spec III cations wlthout notice. A05-1007-004'5f04. dIET