HomeMy WebLinkAbout3772 CARLSBAD BLVD; ; AS080176; Permit7/19/22, 5:23 PM AS080176 Permit Data City of Carlsbad Sprinkler Permit Job Address: 3772 CARLSBAD BL Permit Type: SPRINK Parcel No: 2042512200 Lot #: 0 Permit No: AS080176 Status: ISSUED Applied 11/24/2008 Approved: 11/24/2008 Reference No.: Issued: 11/24/2008 PC #: Inspector: Project Title: PACIFIC SUNSET THREE FIRE SPRINKLER INSPEXTIONS @ $65/EA Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY EL CAJON, CA 619-588-6364 Owner: ZATHAS JOHN J 6384 LOURDES TER SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 about:blank 1/1 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. -v LICENSE : 682025 ,4 DESIGNER : CANDI CAUDILLO DATE : 09-29-2008 4 / FILE : 08-219 JOB NAME : PACIFIC SUNSET 16'FT FLAT LOCATION : 3732 — 78 CARLSBAD BLVD, CARLSBAD, CA da clt) tcac • v th the ' -vile DES I GN DATA. r ptt jr ''"s U11 pecn1t v h cc (11 oc &)IC DESIGN CRITERION: NFPA 13-s td 11 t: tUI b e I rc' MIN SPR FLOW : 13 Gpm flclw.'fl this whel AREA PER SPRINKLER : 256 Sq Ft oate/O/t/ TOTAL CALCULATED AREA : 1024 Sq Ft Wal AS 13 R~CO TOTAL SPRINKLERS CALCULATED : 4 Heads TOTAL SPRINKLER FLOW DOMESTIC DEMAND TOTAL WATER REQUIRED BASE OF RISER NODE: 14 FLOW: 52.2 Gpm 0.0 Gpm 52.2 Gpm 52.2 Gpm PRESSURE: 57.3 Psi APPRQY AS SUBRITD Ii f?FIREDEPARTE AUTHORITY HAVING JURISDICTION CARLSBAD FIRE DEPT. PHONE 760-602-4666 HY1DRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-29-2008 File: C:\RESDEN43\08-219.RES JOB : PACIFIC SUNSET 16'FT FLAT SOURCE STATIC : 80.0 Psi RESIDUAL : 79.0 Psi FLOW : 52 Gpm DESIGN SPRINKLER MANUF : RELIABLE MODEL : RFC 43 CONC/FLAT SPRINKLER Q : .0 Gpm VALVE : 6.0 Psi SPRINKLER P : .0 Psi METER : .0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet ----------------------------------------------------------- FACTOR Psi Gpm 1 32.0 4.3 9.2 13.0 2 32.0 4.3 9.1 13.0 3 32.0 4.3 9.4 13.2 4 32.0 4.3 9.2. 13.1 5 32.0 9.7 6 32.0 9.8 7 32.0 10.3 8 32.0 9.7 9 32.0 9.6 10 23.0 18.7 11 23.0 21.8 12 14.0 37.8 13 14.0 51.5 14 9.0 57.3 15 3.0 59.9 16 3.0 65.9 17 .0 SOURCE 67.2 52.2 SPRINKLERS FLOWING : 4 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 1024 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 52.2 Gpm TOTAL DOMESTIC FLOW : Gpm TOTAL WATER REQUIRED : 52.2 Gpm TOTAL SPRINKLER PRESS : 61.2 Psi WATER METER LOSS : .0 Psi VALVE FIXED LOSS : 6.0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 79.0 Psi by DEMAND PRESS REQUIRED : 67.2 Psi Hydronics Engineering PRESSURE CUSHION : 11.8 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 17.6 F/S (510) 487-9160 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-29-2008 File: C:\RESDEN43\08-219.RES JOB : PACIFIC SUNSET 161 FT FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 13.0 K= 4.3 ------------------------------------------------------------------------------- L= 3.0 Pt 9.2 Pt 9.2 1 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 15.0 .0309 Pf .5 Pn 9.1 8 Pt 9.7 2 q= 13.0 K= 4.3 -------------------------------------------------------------------------- L= 3.0 Pt 9.1 Pt 9.1 2 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 15.0 .0306 Pf .5 Pn 9.0 9 Pt 9.6 3 q= 13.2 K= 4.3 -------------------------------------------------------------------------- L= 2.0 Pt 9.4 Pt 9.4 3 Q= 13.2 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 14.0 .0313 Pf .4 Pn 9.2 6 Pt 9.8 4 q= 13.1 K= 4.3 -------------------------------------------------------------------------- L= 5.0 Pt 9.2 Pt 9.2 4 Q= 13.0 F= 1B1L F= 12.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 17.0 .0309 Pf .5 Pn 9.1 5 Pt 9.7 6 q= .0 K= .0 -------------------------------------------------------------------------- L= 7.0 Pt 9.8 Pt 9.8 5 Q= 13.2 F= 2B F= 10.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 17.0 .0313 Pf .5 Pn 9.7 7 Pt 10.3 7 q= .0 K= .0 -------------------------------------------------------------------------- L= 2.0 Pt 10.3 Pt 10.3 6 Q= 17.8 F= 2B F= 10.0 C= 150 Pe .0 Pv -.2 Vel= 6.0 D= 1.101 TL= 12.0 .0549 Pf .7 Pn 10.1 8 Pt 9.7 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 3.0 Pt 9.7 Pt 9.7 7 Q= 8.2 F= 2B F= 10.0 C= 150 Pe .0 Pv -.1 Vel= 2.8 D= 1.101 TL= 13.0 .0131 Pf .2 Pn 9.7 9 Pt 9.6 8 q= .0 K= .0 -------------------------------------------------------------------------- L= 11.0 Pt 9.7 Pt 9.7 8 Q= 4.8 F= 2B F= 10.0 C=150 Pe .0 Pv .0 Vel= 1.6 D= 1.101 TL= 21.0 .0048 Pf .1 Pn 9.7 9 Pt 9.6 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 32.0 Pt 9.7 Pt 9.7 9 Q= 21.3 F= 4B2L F= 34.0 C= 150 Pe 3.9 Pv -.3 Vel= 7.2 D= 1.101 TL= 66.0 .0762 Pf 5.0 Pn 9.4 10 Pt 18.7 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 09-29-2008 File: C:\RESDEN43\08-219.RES JOB : PACIFIC SUNSET 161 FT FLAT PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 7 q= .0 K= .0 ------------------------------------------------------------------------------- L= 23.0 Pt 10.3 Pt 10.3 10 Q= 31.0 F=2R232L F= 26.0 C= 150 Pe 3.9 Pv -.7 Vel= 10.4 D= 1.101 TL= 49.0 .1527 Pf 7.5 Pn 9.6 11 Pt 21.8 10 q= .0 K= .0 -------------------------------------------------------------------------- L= 20.0 Pt 18.7 Pt 18.7 11 Q= 21.3 F= 3R2B1L F= 20.0 C= 150 Pe .0 Pv -.3 Vel= 7.2 D= 1.101 TL= 40.0 .0762 Pf 3.0 Pn 18.4 11 Pt 21.8 11 q.= .0 K= .0 -------------------------------------------------------------------------- L= 11.0 Pt 21.8 Pt 21.8 12 Q= 52.2 F= 1B2L F= 19.0 C= 150 Pe 3.9 Pv -2.1 Vel= 17.6 D= 1.101 TL= 30.0 .4017 Pf 12.1 Pn 19.7 12 Pt 37.8 12 q .0 K= .0 -------------------------------------------------------------------------- L= 66.0 Pt 37.8 Pt 37.8 13 Q= 52.2 F= 11R3L1BF= 41.0 C= 150 Pe .0 Pv -.8 Vel= 11.0 D= 1.394 TL= 107.0 .1273 Pf 13.6 Pn 37.0 13 Pt 51.5 13 q= .0 K= .0 -------------------------------------------------------------------------- L= 5.0 Pt 51.5 Pt 51.5 14 Q= 52.2 F= 1C4R1S1L 23.0 C= 150 Pe 2.2 Pv -.8 Vel= 11.0 D= 1.394 TL= 28.0 .1273 Pt 3.6 Pn 50.7 14 Pt 57.3 14 q= .0 K= .0 -------------------------------------------------------------------------- L= 15.0 Pt 57.3 Pt 57.3 15 Q= 52.2 F= 3L1C F= 16.5 C= 120 Pe 2.6 Pv .0 Vel= .5 D= 6.605 TL= 31.5 .0001 Pf .0 Pn 57.3 15 Pt 59.9 15 Q= 52.2 -------------------------------------------------------------------------- Pt 59.9 BFV FIXED PRESSURE LOSS Valve 6.0 16 Pt 65.9 16 q= .0 K= .0 -------------------------------------------------------------------------- L= 60.0 Pt 65.9 Pt 65.9 17 Q= 52.2 F= 3C F= 2.0 C=120 Pe 1.3 Pv .0 Vel= .5 D= 6.605 TL= 62.0 .0001 Pt .0 Pn 65.9 17 Pt 67.2 -------------------------------------------------------------------------- Meter = .0 18 Q= 52.2 <<< -------------------------------------------------------------------------- -------------------------------------------------------------------------- SOURCE >>> Pt 67.2 E=>45-Elb L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 09-29-2008 FILE : C:\RESDEN43\08-219.RES JOB : PACIFIC SUNSET 16'FT FLAT PSI FIRE SPRINKLER HYDRAULIC GRAPH 1001--.- ........................... . 91 80 70 30 - 20 10 [I 20 30 40 50 0 Supply Curve Static : 80.0 Resid : 79.0 Flow : 52.0 60 70 80 90 100 FLOW - Gpm Demand Curve Avl Pr : 79.0 @ 52 Req Pr : 67.2 @ 52 Pr Cush: 11.8 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bi, Suite 609, Fremont, CA. 94555. (510) 487-9160. C (0 0 0 0) (0 Bulletin 006 Rev.D A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2.112" (13mm) Total adjustment. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 and RFC49 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive appearance and 1/2I (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 and RFC49 are UL Listed Residential Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 13D. The RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43 and RFC49, for residential installations, use a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to ,2" (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise until the skirt flange makes full contact with the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate I Max. Ambient Temp. I 165°F/74°c 135°F/57°C 100°F/38°C I Installation Data: RFC43 (SIN RA0612) Thread Size inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wall ft. (m) Minimum Distance between sprinklers, ft. (m) Minimum Required Sprinkler Discharge Flow Press. gpm (Lpm) psi (bar) 1/2 (15mm) 4.3 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8(0.54) 1/2 (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 9.1 (0.63) h/2 (15mm) 4.3 16 x 16 (4.9x4.9) 8(2.43) 8 2.43) 13 49) 9.1 (0.63) ½" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(1.21) 1,/2 (15mm) 4.3 20 x 20 (6.0x6.0) 10(3.05) 8(2.43) 21 (79) 23.8(1.64) Note: 1 bar = 100 Kpa Installation Data: RFC49 (RA0616) Thread Size inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wall ft. (m) Minimum Distance between sprinklers, ft. (m) Minimum Required Sprinkler Discharge Flow Press. gpm (Lpm) psi (bar) ½" (15mm) 4.9 12 x 12 (3.6x3.6) 6(1.83) 8 (2.43) 13(49) 7.0(0.48) ½" (15mm) 4.9 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13 (49) 7.0(0.48) ½" (15mm) 4.9 16 x 16 (4.9x4.9) 8(2.43) 8 (2.43) 13 (49) 7.0(0.48) 1/2 (15mm) 4.9 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 17 (64.3) 12.0(0.83) 1/211 (15mm) 4.9 20 x 20 (6.0x6.0) 10 (3.05) 8(2.43) 20 (75.7) 16.7 (l.14) Note: 1 bar = 100 Kpa FOR SLOPED CEILING APPLICATIONS SEERO BULLETIN O3] 2. Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (5711C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a 1/2" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulletin 006). Model RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gprrVft2. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3 (62.4), having a 7/16' orifice. Temperature rating shall be Ordinary 165°F (740C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On Feature Cover Plate Finishes " Standard Finishes I Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 1" x 7/2" REDUCING TEE OR ELBOW - - ~i- - - + 0/A. 2J" [58. CEILING CUP 2" [50.8mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING -I " [12.7mm] MAX, I 3,j"DIA. COVER ADJUSTMENT COVER PLATE [84. 1mm] [48mm] ASSEMBLY SPRINKLER O6FOI COVER PLATE.' 1/2" [12.7mmj ADJUSTMENT tqCC /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB 28, 4.2, 5. 6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.81K, 1/2"NPT 1Y1231 - Pendent 2.8K, 1/2"NPT 1Y2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT 1Y3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.01K, 3/4"NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 MARCH, 2007 TFPI7I 7 Page 2 01? © ESCUTCHEON 7/16 (11,1 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN TFPI71 STYLE 10 or 20 RECESSED _____ ESCUTCHEON SSP DEFLECTOR* I- 2-7/8" (73,0 mm) DIA. -1 DEFLECTOR I 7/16" (11.1 mm) NOMINAL MAKE-IN I 2-3/16" H (55,6 mm) 1/2" NPT I _F_ — 2-1/4 (57,2 mm) 1-9/16" (39,7 mm) PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI 131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT STYLE 10 or 20 RECESSED ESCUTCHEON SSU ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2" MAKE-IN NPT 2-3/16" (55,6 mm) 1-1/2" (38,11 mm) SSP DEFLECTOR * H 2-7/8" (73,0 mm) DIA. 'JI!IIUA NOMINAL —4 FLATS __ frlNPT I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFPI7I ESCUTCHEON 7/16 (11,1 mm) PLATE SEATING 1/2 NOMINAL SURFACE NPT MAKE-IN 2-3/16' ____ (55,6 mm) 1-1 (38,11 mm) Pa 3 of 10 STYLE 10 or 20 RECESSED ___Sjk_ ESCUTCHEON DEI-Lb.GIUI-( 6* (11,1mm) NOMINAL MAKE-IN 2-3/16" : ; 7/16' 1 5 55,6 mm) WRENCH FLATS 1/2" NPT I SSP DEFLECTOR * H 2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING 3/4fl NOMINAL SURFACE MAKE-IN NPT 2-5/16" (58" mm) \ I I 1-9/16" I (39,7 mm) STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR 6* 1/2" t1 (12,7 mm) NOMINAL 4 MAKE-IN 2 2-1/4" (57,2 mm) CROSS SECTION WRENCH FLATS SSP DEFLECTOR* I 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 7/16(11,1 mm) NOMINAL 1/2" MAKE-IN NPT 2-1/4"I (57,2 mm) RENCH1-9/16" (39,7 mm)FLATS DEFLECTOR PENDENT UPRIGHT CROSS SECTION SSu * DEFLECTOR Pane 4 of 10 TFPI7I 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi1'2 (40,3 LPM/bar1'2) K = 4.2 GPM/ps1112 (60,5 LPM/barl/2) K = 5.6 GPM/psi1'2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/bar1') Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K2.8) .......Bronze The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. le Pe a of 1© TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** f POLYESTER LEAD COATED 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57C Orange 123456,7 1,2,3,5 155"F/68°C Red 175"F/79°C Yellow 200°F/93°C Green 286°F/141"C Blue 1/2 NPT 135°F/57°C Orange 1, 2,4, 5 N/A RECESSED PENDENT (TY3231)* Figure 10 155°F/68"C Red 175°F/79"C Yellow 200°F/93"C Green 135°F/57°C Orange 1,2,3,4, 5 I I I I I 1,2,4,5 Green N/A RECESSED PENDENT (TY3231)** Figure 11 155°F/68°C Red 175F/79°C Yellow 200°F/93°C 8.0 PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2, 3, 4, 5, 6, 7 1,2,5 155°F/68°C Red 175°F/79"C Yellow 200"F/93°C Green 286°F1141°C Blue 3/4" NPT RECESSED PENDENT (TY4231)" Figure 12 135°F/57"C Green 1,2,4, 5 N/A 155°F/68"C Orange 175°F/79°C Red 200"F/93"C Yellow 135°F/57"C Orange 1,2, 3,4, 5 N/A RECESSED PENDENT (TY4231)** Figure 13 155"F/68C Red .175°F/79°C Yellow 200°F/93"C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57°C Orange 1, 2, 4, 5, 6 Blue 1, 2, 5 155°F/68"C Red 175°F/79°C Yellow 200°F/93°C Green - 286°F/141"C NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP17° Page 7 of 110 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (1Y3131) 175 PSI (12,1 BAR) N/A 1/2° RECESSED PENDENT NPT (1Y323) PENDENT (TY4231) and 4.2 UPRIGHT (1Y4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (1Y3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (1Y3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (1Y3231) (SEE NOTE 1) N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (TY4231) N/A 80 PENDENT (1Y4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4631) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPTsprin k/er joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Pe 8 of - 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) I (15,9±6,4 mm) - 2-1/4" 01k 1/4 (6,4 mm) MOUNTING FACE OF I SPRINKLER PLATE FITTING 57 2mm) 1/8" (3,2m MOUNTING // I 7 SURFACE , / CLOSURE SERIES 6" (33,3 mm) TV-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. • i 5/8±1/4" (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57 2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8 / ____ MOUNTING SURFACE/ .... CLOSURE SERIES 1-1/4'( mm) I TY-FRB 3/4" (19,1 mm) FIGURE 8 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2K-FACTOR, 1/2 INCH NPT TFP17I 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I FACE OF (57,2 mm) MOUNTING I 1/8") SPRINKLER PLATE FITTING I (32mm) t MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mmi TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) 1 FACE OF (57,2 mm) PLATE MOUNTING FITTING (32mm) I__SPRINKLER MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section), Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFP1711 - 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA 1/4" (6,4 mm) I FACE OF (57,2 mm) MOUNTING SPRINKLE PLATE FITTING 1/8" (32 m)J.. MOUNTING SURFACE SERIES 1-1/4" (31,8 mm)CLOSURE TYFRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 3/4" (19,1 mm) 5/8±1/4" (73,0 mm) - (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF (57,2 mm) MOUNTING PLATE FITTING SPRINKLER I __ _____________ (32 mj MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13116" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA, (73,0 mm) 1/2±1/8" 1/2" (12,7 mm) E (12,7±3,2 mm) 2-1/4" DIA, I 1/4" (6,4 mm) FACE OF (57.2 mm) I # I I MOUNTING I SPRINKLER I PLATE FITTING (32mm) t \ MOUNTING I SURFACE SERIES 1-1/4(31,8 mm) CLOSURE TY.FRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) FACE OF I MOUNTING SPRINKLER FITTING PLATE / (3.2 mm( MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. ' E ' TA L. i F L .. i t\ L APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. The Model 350 shall provide protection where a potential health hazard does not exist. FEATURES STANDARDS COMPLIANCE: (Sizes 2 112"-1O" Horiz. & Vert.) Sizes: U2 1/2" U 3" U 4" U 6" U 8" 010" U 12" (Size 12" horizontal) Maximum working water pressure 175 PSI ASSE® Listed 1015 Maximum working water temperature 1405F CSA® Certified (2-1/2' - 10) Hydrostatic test pressure 350 PSI End connections IAPMO® Listed (Grooved for steel pipe) A\MNA C606 S AWWA Compliant C510 (Flanged) ANSI 1316.1 UL® Classified Class 125 OPTIONS ' C-UL® Classified (Suffixes can be combined) FM® Approved (2-1/2" - 10") U - with NRS shut-off valves (standard) Approved by the Foundation for Cross Connection U FS - with cast iron Wye type strainer Control and Hydraulic Research at the University of (flanged only 2-1/2-10") Southern California (2-1/2" - 10") U FSC - with epoxy coated Wye type strainer (flanged only 2-1/2-10') * NYC MEA 50-01-M (2-112"3") U G - with groove end gate valves (2-1/2" - 10') NYC MEA 297-98-M (4-6") U GF - with grooved inlet gate connection and flanged NYC MEA 316-01-M (8"-1 0") outlet gate connection (2-1/2" - 10') U FG - with flanged inlet gate connection and grooved MATERIALS outlet gate connection (2-1/2" - 10") U L - less shut-off valves (flanged body connections) Main valve body Ductile Iron ASTM A 536 Grade 4 U OSY - with OS & Y gate valves Access covers Ductile Iron ASTM A 536 Grade 4 U P1 - Post Indicator gate Valve (3-12") Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series ACCESSORIES NORYLTM, NSF Listed U Repair kit (rubber only) Fasteners Stainless Steel, 300 Series U Thermal expansion tank (Model WXTP) Seal ring EPDM (FDA approved) U OS & Y Gate valve tamper switch (OSY-40) 0-ring Buna Nitrile (FDA approved) U Test Cock Lock (Model TCL24) Springs Stainless Steel, 300 Series W Attention: Model 350 IjiF (flange body) and Y-± IC - I ..4 350A (grooved body) ____ A have different lay 1 MODEL 3500SYG SHOWN ABOVE lengths. DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSION lnpponimato) WEIGHT SIZE in. mm A in. mm 8 LESS GATE VALVES in. mm C in. mm 0 in. mm E V OPEN 056 in, mm E OS&V CLOSED in. mm E NRS GATE in mm F in. mm G in mm WITHOUT GATES VALVES lbs. kg WITH NRS GATE VALVES lbs. I kg WITH OS&Y GATE VALVES lbs. kg 2 1/2 65 31 791 157/8 403 33/4 95 71/4 184 163/8 416 /3718 352 11 318 289 31/2 89 41114 1048 53 24.1 155 70.4 163 74 3 80 32 816 15718 403 33/4 95 7 114 164 18718 479 15518 397 123/8 314 3 1/2 89 42314 1086 53 24.1 177 804 183 83 4 100 375/9 956 191/2 495 41/2 114 8 203 22314 576 18114 464 143/4 375 6 152 523/4 1340 91 41.3 271 123 281 127.6 6 150 44 314 1137 231/2 597 6 152 10 254 301/8 765 233/4 603 19 463 7 178 623/4 1594 165 74.9 449 203.8 465 211 8 200 603/4 1543 373/4 959 10 254 11 279 373/4 999 291/ 743 22 112 572 8 1/2 216 85 2159 358 162.5 810 367.7 834 3765 10 250 63314 1619 373/4 959 10 254 11 279 453/4 1162 353/8 699 26 1/2 673 8 1/2 216 93 1/4 2369 368 176.2 1148 521.2 1206 547.5 12 300 66 1/4 1683 36 965 10 204 12 305 531/6 1349 405/8 1032 30 762 9 229 n/a n/a 447 202.8 1493 6772 1607 729 (-Patent No. 5,911,331 iiimi iii • iiu Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com FLOW CHARACTERISTICS MODEL 3502 1/2",3" & 4" (STANDARD & METRIC) FLOW RATES (I/a) 0 6.3 12.6 18.9 25.2 31.5 37.8 44.1 50,4 In 0 100 200 300 400 500 600 700 FLOW RATES )GPM) MODEL 350 6" & 8" (STANDARD & METRIC) FLOW RATES (Ifs) 0.0 25.2 50.4 75.6 100.8 126.0 0 400 800 1200 1600 2000 FLOW RATES )GPM) MODEL 350 10" & 12" (STANDARD & METRIC) FLOW RATES (I/o) 0.0 63.0 126.0 189.0 15 10 W Q. 0 1000 2000 3000 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATION 151.2 104 ow 0 69 35 ED LU 00. 2400 252.0 104 In 0 69 W ... 35 LU 0 IX 0. 4000 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 DIRECTION OF INDOOR INSTALLATION VERTICAL INSTALLATION (350GF) (350G) SPECIFICATIONS The Double Check Backflow Prevention Assembly shall beASSE® Listed 1015, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Backflow Prevention Assembly shall be a WILKINS Model 350. FLOW 4> WILKINS aZurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: 905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1 -877-222-5356) Website: http://www.zurn.com Page 2 of 2