Loading...
HomeMy WebLinkAbout1163 OAK AVE; ; AS050180; Permit7/19/22, 4:48 PM AS050180 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1163 OAK AV Permit Type: SPRINK Parcel No: 2050205200 Lot #: 0 Permit No: AS050180 Status: PENDING Applied 9/12/2005 Approved: Reference No.: Issued: PC #: Inspector: Project Title: O'GARA RESIDENCE RESIDENTIAL FIRE SPRINKLER SYSTEM Applicant: Owner: ALPHA FIRE PROTECTION P0 BOX 598 VISTA CA 760-727-6993 Fees ($) Add'I Fees ($) Total ($) Balance ($) 120 0 120 0 about:blank 1/1 ALPHA FIRE PROTECTION RESIDENTIAL FIRE SPRINKLER SYSTEM DATA BLOCK: JOB ADDRESS: 1163 OAK AVE. CARLSBAD, CA ASSESSOR'S PARCEL NUMBER: 205-020-52 OWNER'S NAME: MIKE O'GARA OWNER'S PHONE NUMBER: GENERAL CONTRACTOR'S NAME: OWNER GENERAL CONTRACTOR'S ADDRESS: GENERAL CONTRACTOR'S PHONE NUMBER: SPRINKLER CONTRACTOR'S NAME: ALPHA FIRE PROTECTION Asoc5oiso SPRINKLER CONTRACTOR'S ADDRESS: 770 SYCAMORE AVENUE SUITE J #477 VISTA, CA 92083 SPRINKLER CONTRACTOR'S PHONE NUMBER: (760) 727-6993 JOB SITE PHONE NUMBER: N/A HYDRAULIC NOTES: WATER METER SIZE: 1" METER ELEVATION:3' PRESSURE AT METER: 98PsI FLOW (GPM): HOUSE SIDE OF METER: 50 GPM PAD ELEVATION: 6' PRESSURE AT PAD: 96 PSI PIPE LENGTH: METER To RISER: 165' PIPE TYPE/SIZE: METER To RISER: PVC, 1 1/2" SPRINKLER TABLE: WATER INFORMATION FROM GALE @CARLSBAD WATER DIST. DATE: 8/25/05 @ 9AM PHONE (760) 438-2722 SYMB COMPANY & MODEL ORF TYPE TEMP K-FAT CANOPY QTY • Reliable RCP43 1/2 SSP 155 degree 4.3 White Concealed 20 o Reliable FR-Fl 1/2 SSP 200 Degree 5.6 White Recessed 4 TOTAL 24 PIPE TABLE: TYPE MFG MODEL AREA OF USE CPVC HARVEL BLAZEMASTER SYSTEM STEEL AMERICAN SCHEDULE 40 RISER COPPER MULLER TYPES M & L SUPPLY PVC SPEARS SCHEDULE 40 SUPPLY NOTE: PIPE MUST BE U.L. OR F.M. LISTED FOR RESIDENTIAL FIRE SPRINKLER USE. PLANS MUST STATE: "PIPE WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS." "A COPY OF PIPE MANUFACTURER'S INSTALLATION INSTRUCTION PAMPHLET MUST BE KEPT ON-SITE." Alpha Fire- Hydraulic Calculations CntracName: D 3 OAt& C j#.O Sheet / of / Calculation for: pa:rn) /?X/? Date: 92 $ Nozzle Type & Location Flow In GPM - Pipe Size Inches Fittings And Devices Pipe Fittings Total Friction Loss psi/ft Required Pressure psi Elevation Node Notes Q *2 I q Q Type j/( Diameter/ C-Factor I /-IC. Ln / o 0-I / Pt /7.50 / —77,05 Ft I 2 N' .70 Pe Tot 13 q Q Type Diameter C-Factor Ln - Pt Is, Ft Pf Tot Pe q Q .ff TyPe//_ Diameter/ C-Factor/5Z Ln 9 () t4 I Pt 7,50 7 / -T- I Ft " :Z Tot 1 7 Pc - q Q % Typ Diameter/ C-Factor/h . f( Ln 5 / I Pt /1q '1 3 7 _____ Pf /5,W -Ti2. Tot? Pe (p 5) q Q 34 Iype73 , Diameter I C-Factor )Z) - 2, M Ln 2 f;'37 Pt 40. 7D(2 1Z.*,irc 1 -c4' Ft Pf 4.2.-3 / _,/5 Tot ,i7 Pe 87 q 340 Type( Diameter I C-Factor / $ -______ Ln 5 Pt g 7, 7/L ,3o 12 Ft CT '' 3.23 Tot , 3 Pe 73 q Q 34 Type, Diameter C-Factorijo Ln Pt e 2/I 061 _______ Ft Pf /, (.3 Tot /(2'5 Pe ,/ 3 q Q 3 , Typ e Diameter 'fj C-Factor I Ln Pt ______ Ft ' 5' 00 Tot Pe q Q Typejp Diameters C-Factor I) . Ln , jg(po Pt(p,// U6.3 3 Ft Pf 5'/ 5 ________ Tot Pc ).30 q Q Type Diameter C-Factor Ln Pt 66 .570 SJ (2. Cs $,?Oi Ft Pe P1 Tot q Q Type Diameter C-Factor Ln Pt -76 3 Ft Pf Tot Pe q Q Type Diameter C-Factor Ln Pt Ft Pf Tot Pc Caution Read Carefully! Installation Instructions For: Model F1 FR Sprinklers Standard Upright Standard Pendant Vertical Sidewall Horizontal Sidewall With HSW1 Deflector Extended Coverage Pendent Extended Coverage Horizontal Sidewall With EC-6, EC-8 or EC-9 Deflector Conventional Intermediate Level Pendent Intermediate Level Upright Model Fl FR Recessed Sprinklers Recessed Pendent Recessed Extended Coverage Pendent Recessed Extended Coverage Horizontal Sidewall With EC-6, EC-8 or EC-9 Deflector Approvals: Refer to Bulletins 136, 148 or 170 for approval information especially regarding finishes and recessed escutcheons. Identification Standard Sprinkler -Spray Upright (Fig. A) -Install in upright position only. Identified by markings "SSU" on deflector. Standard Sprinkler - Spray Pendent (Fig. B) - Install in pen- dent position only. Identified by markings "SSP" on deflector. Sidewall Sprinkler - Vertical (Fig. C) - Install in upright posi- tion or pendent position with deflector flow arrows pointing away from near wall. Identified by markings "SIDEWALL' on deflector. x*dType Deflector to Ceiling Dimension (Mlii. - Max.) Upi1 Pendent 4"- 12"(152n-rm) Small Orifice Sprinkler - Upright (Fig. D) or Pendent (not shown). Identified by pintle projecting from deflector. Conventional (Fig. E) - Install in either upright or pendent po- sition. Identified by marking "CONy" on deflector. Do not use this sprinkler as a replacement for a standard spray sprinkler. Intermediate Level Sprinkler - Pendent (Fig. F) same as Standard Spray Pendant (Fig. B) except for shield. NOTE: The protective shield must be assembled in the field (see Caution Sheet CA-18C). Intermediate Level Sprinkler- Upright (Fig. G) same as Stan- dard Spray Upright (Fig. A) except for shield. Model Fl FR Model F1 FR Recessed Quick Response Sprinklers Upright Figure A t1. Pendent Figure B J Vertical Sidewall Figure C Small Orifice Upright (WI Pinde) Ficue D conventional R,e E Intermediate Level Pendent Rue F Intemecliate Level Upright Rue G Honzontal Sidewall Figure H Recessed Pendant Figure I Ext Coy. l-icrizontal Side— wall EC-6, EC-8,or EC-9 FlseJ Alk Ext. Coy. l-bia:ilai SideweiEC8erEC-9 FI.ieK Ext. Cov. Pendent FigireL Rec. Ext. Coy. Pendent Figure M Standard Temperature Ratings kAikuii sple No ______ Collar IIanAmblerdTwaeiLu8 F "C "F "C Orcl,ery 138 57 Ca'pe 1(X) 38 Orcfrssy 155 68 Red 1- 38 lntemediaie 175 79 Ye&m 150 66 Interre( 20) 93 Green 150 66 I-llgh 286 141 B.e 225 107 '"Not Avallatile for Recessed Note: When Installing Model F1FR Sprinklers, use the Model D Sprinkler Wrench and when installing Model F1FR Recessed sprinklers, use the Model RC1 (Pendent) or GFR1 (Horizontal Sidewall) Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Caution RFC43 (SIN RA0612) and RFC56 (SIN RA0914) Flat Concealed Residential Sprinkler Read Carefully! Installation Instructions General Instructions Do not pull onthedefleclor when moving Model RFC43 and R9M Spri,lders from the shippng carton. Install =1~ ceding is 3. Never any olher coaling to spdrder or concealed — cover plate. Do not instaø concealed sprinklers in ceilings which hae positive pressure in the space above, and do not cover the cup vent holes An open plenum space must be abavethespthdercu Use the pitiper wrench (Ags. 1 and 2) to install sprinklers. Face i sprinkler fitting b ceiling is? for theRFC42and 2 (e" for the RFC56. Ceding hole diameter is Final adistmert of each cover is made by hend turrng the cover plate in the clockwise direction until it is tight against the ceiling. Approval Organizations Underwriters Laboratories Inc. and I ULcertifiedfor Canada (cULus) UU Listin Residential AuWrnaficrinklers UU Guide Number: VKKW Models RFC43 and RFC56 are UL Listed Residential Sprinklers and are intended for use in accordance with NFPA13 Paragraph 4-3.6 in residential portions of any occupancy, in one and two family dwellings and mobile homes, (NFPA-13D), and residential occupancies up to four stories in height (NFPA-13R). The letters uRf43• or MRFC56" temperature, K factor, and year are stamped on the deflector. Cover plate: 135°F (57°C) =Pererssu- Rating: 165°F(74°C) 175 psig Max. Ceiling Temp.: 100°F (38°C) When in doubt as to ceiling temperature, measure with an accurate thermometer. Installation Model RFC43 and RFC56 sprinklers are to be installed in ceilings with a plenum space above that does not have positive pressure. In addition, inspect all sprinklers after installation to ensure that both the gap between the cover plate and ceiling and the (4) slots in the cup are open and free of any air flow impediment. After a 2% inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the proper wrench (Figs. 1 and 2). When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND RFC56 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Technical Data - mom I F.aor iig I __ Oic.b L) ____ Fbw I cJI Pè* p,—_. C 04 One one I ½'(15). 4.3 12x12 6 12 I 7.8 f 8 WI (15) 4.3 14x14 7 13 I 9.1 8 RFC43 W'(15) I 4.3 I 16x16 I 8 13 I 9.1 8 - WI (15) 4.3 I 18x18 I 9 18 17.5 8 W' (15) I 4.3 20 x 20 10 21 123.8 8 W'(15) I 5.6 12x12 6 26 21.6 8 RFC56 WI (15) f 5.6 14 x 14 7 26 21.6 8 W'(15) 5.6 16x 16 1 8 26 21.6 8 The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 CA-141 Rev.A