Loading...
HomeMy WebLinkAbout1200 OAK AVE; ; AS090054; PermitPermit No: AS090054 Job Address: 1200 OAK AV Permit Type: SPRINK Parcel No: 1561804800 Lot #: 0 Status: ISSUED Applied 6/11/2009 Approved: 6/11/2009 7/19/22, 5:09 PM AS090054 Permit Data City of Carlsbad Sprinkler Permit Reference No.: Issued: 6/11/2009 PC #: Inspector: Project Title: LOT 2 TWO FIRE SPRINKLER INSPECTIONS @ $65./EA Owner: BUSBY GENE Applicant: INNOVATIVE FIRE PROTECTION SUITE 101 8779 COTTONWOOD AV SANTEE, CA (619) 593-8200 (619)593-9133 1212 OAK AVE CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 oo6 J CARLSBAD FIRE FROTERCTION SERVICES Permit Submittal Form A. Check or fill in pertinent information for type of permit you are submitting. AS —Automatic Sprinklers Commercial Residential_________________ Number of Heads per System: System 4 Heads 42- System # Heads System #2.- Heads System # Heads___ System Ii Heads System # Heads Underground included for approval 00 Underground included for reference pnly Total-Fees FA - Fire Alarm ]0 Devices orless Over 10 devices # of devices Total Fees FS - Fired Systems (Circle One) Hood & Duct, Halon, Special Chemical Agent, Standpipe, Total Fees Spray Booth, or Appliance. There maybe an additional fee of $55.00 per 1/2 for Failed Inspections. Address ofjob site: - O7//2-O Suite Building Permit #.CB Contractor Information Name t 6v4n k 770?J IA/C. Address ei AIWZ(i 4V1 City, State, Zip JiE7 CA 2o -71 ___ Kind of License and number t1 ( _Phone 13 2Q9 FAX 3--'1( :5 Do you currently have a Certificate of Insurance on file with the Fire Dept ?or N Do you currently have a business license on file with the City of CarlsbadZr N Signature JJ_Date £4' Permit Submttal Form 02/02/2001 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE; OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 85.0 81.0 500.0 85.0 31.1 60.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 60.0 31.1 2 0.0 - - - - 49.8 - - - 2A 0.0 - - - - 45.8 - - - 3A 0.0 HOSE STREAM 44.5 5.0 3 0.5 - - - - 42.3 - - - 4 3.5 - - - - 39.3 5 10.5 - - - - 32.3 6 10.5 - - - - 31.6 - - - 7 22.0 - - - - 23.6 - - - 8 22.0 - - - - 23.0 9 22.0 - - - - 23.0 - - - 10 22.0 - - - - 23.0 - - - 10A 21.5 - - - - 23.2 hA 21.5 - - - - 23.2 - - - 12 22.0 - - - - 20.5 - - - 13 27.0 - - - - 9.4 13A 26.5 K= 4.30 9.1 13.0 14A 26.5 K= 4.30 9.2 13.0 These plans have been reviewed for apparent compliance with the current applicable cdes and staiidardin force in the junsclicuon. Tbe.wnr or contractor May utilize this review in support of an appjication for a huildlntt perinhl with the express understanding that this review in no way relieves the owner or contractor or their proi'èssional engineer or architect, for sole responsibility for full col pliance with said codes and standards. th including e hiiildiitg code or forany responsihihy for dct1i.tencis. errors. omissions or negligence in these plans whether, or not tinted in this review. Dale: /02/0Reviewer RECOMMENj) APPRfVAL 0 RECOMMEND APPROVAL. AS NOTED I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 30.00 PF 10.2 1 0.0 SRCE 60.0 (N/A) 12.8 150 FTG TLG PE 0.0 2 0.0 0.0 49.8 0.0 0.251 TL 40.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 49.8 0.0 4.0 psi, 31.0 gpm 2A 0.0 0.0 4518 0.0 Pipe: 3 31.0 1.590 PL 40.00 PF 1.3 2A 0.0 0.0 45.8 0.0 5.0 150 FTG 4L PE 0.0 3A 0.0 H.S. 44.5 5.0 0.026 TL 52.00 PV Pipe: 4 26.0 1.265 PL 10.00 PF 2.0 3A 0.0 H.S. 44.5 5.0 6.6 150 FTG T3LC PE -0.2 3 0.5 0.0 42.3 0.0 0.056 TL 36.00 PV Pipe: 5 26.0 1.049 PL 3.00 PF 1.7 3 0.5 0.0 42.3 0.0 9.7 120 FTG C PE -1.3 4 3.5 0.0 39.3 0.0 0.212 TL 8.00 PV Pipe: 6 26.0 1.101 PL 20.50 PF 3.9 4 3.5 0.0 39.3 0.0 8.8 150 FTG ET3R PE -3.0 5 10.5 0.0 32.3 0.0 0.111 TL 35.50 PV Pipe: 7 26.0 1.101 PL 1.50 PF 0.7 5 10.5 0.0 32.3 0.0 8.8 150 FTG T PE 0.0 6 10.5 0.0 31.6 0.0 0.111 TL 6.50 PV Pipe: 8 26.0 1.101 PL 13.00 PF 3.0 6 10.5 0.0 31.6 0.0 8.8 150 FTG ET2R PE -5.0 7 22.0 0.0 23.6 0.0 0.111 TL 27.00 PV Pipe: 9 26.0 1.101 PL 0.50 PF 0.6 7 22.0 0.0 23.6 0.0 8.8 150 FTG T PE 0.0 8 22.0 0.0 23.0 0.0 0.111 TL 5.50 PV Pipe: 10 0.0 1.101 PL 33.00 PF 0.0 8 22.0 0.0 23.0 0.0 0.0 150 FTG E2T5R PE 0.0 9 22.0 0.0 23.0 0.0 0.000 TL 55.00 PV Pipe: 11 0.0 1.101 PL 20.50 PF 0.0 9 22.0 0.0 23.0 0.0 0.0 150 FTG ET2R PE 0.0 10 22.0 0.0 23.0 0.0 0.000 TL 34.50 PV Pipe: 12 0.0 1.101 PL 0.50 PF 0.0 10 22.0 0.0 23.0 0.0 0.0 150 FTG TR PE 0.2 bA 21.5 0.0 23.2 0.0 0.000 TL 6.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 0.0 1.101 PL 10.50 PF 0.0 10 22.0 0.0 23.0 0.0 0.0 150 FTG TR PE 0.2 hA 21.5 0.0 23.2 0.0 0.000 TL 16.50 PV Pipe: 14 26.0 1.101 PL 19.00 PF 2.4 8 22.0 0.0 23.0 0.0 8.8 150 FTG 3R PE 0.0 12 22.0 0.0 20.5 0.0 0.111 TL 22.00 PV Pipe: 15 26.0 1.101 PL 45.50 PF 8.9 12 22.0 0.0 20.5 0.0 8.8 150 FTG 2E4TR PE -2.2 13 27.0 0.0 9.4 0.0 0.111 TL 80.50 PV Pipe: 16 13.0 1.101 PL 4.00 PF 0.5 13 27.0 0.0 9.4 0.0 4.4 150 FTG ETR PE 0.2 13A 26.5 4.3 9.1 13.0 0.031 TL 17.00 PV Pipe: 17 13.0 1.101 PL 7.00 PF 0.5 13 27.0 0.0 9.4 0.0 4.4 150 FTG ER PE 0.2 14A 26.5 4.3 9.2 13.0 0.031 TL 15.00 PV NOTES (HASS) Calculations were performed by the HASS 8.0 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.067 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.8 ft/sec at pipe 1. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP 1 I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00. 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC:. 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM WATER SUPPLY ANALYSIS Static: 85.00 psi Resid: 81.00 psi Flow: 500.0 gpm 100. 1 80.' G A U G E 602 P R E 40. S U R E )L LL )L LEGEND Available pressure 84.98 psi @ 31.1 gpm Required pressure 60.02 psi @ 31.1 gpm Source Supply Curve System Demand Curve 20.' )L p S i 20C300 400 500 600 700 800 900 1000 FLOW (GPM) - SPRINKLER SYSTEM .HYDRAULIC ANALYSIS Page 6 DATE 9/11/2009 : C:'\HASS74\C4211-REV.SDF JOB:T]TLE: OAK AVE. LOT #2 TWO HEAD CALC-M. BEDROOM WATER SUPPLY CURVE 96+ 88+ *\\\\\\\\ o I * <-81.0 psi @ 500 gpm 80+ Flow Test Point 72+ P 64+ R I E X S I S 56+ U I R I E I 48+ P I S I I 40+ 32+ 24+ 16+ LEGEND X = Required Water Supply 60.02 psi @ 31.1 gpm 8+ 0 = Available Water Supply I 84.98 psi @31.lgpm 0++-+---+----+-----+------+ --------+ --------+ ---------+------------ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-REAT ROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 85.0 81.0 500.0 85.0 31.2 56.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 56.8 31.2 2 0.0 - - - - 46.5 - - - 2A 0.0 - - - - 42.5 3A 0.0 HOSE STREAM 41.1 5.0 3 0.5 - - - - 38.9 4 3.5 - - - - 35.8 5 10.5 - - - - 28.8 6 10.5 - - - - 28.1 - - - 7 22.0 - - - 20.1 - - - 8 22.0 - - - - 19.5 - - - 9 22.0 - - - - 13.3 10 22.0 - - - - 9.4 - - - 10A 21.5 K= 4.30 9.4 13.2 hA 21.5 K= 4.30 9.1 13.0 12 22.0 - - - - 19.5 - - - 13 27.0 - - - - 17.3 13A 26.5 - - - - 17.5 - - - 14A 26.5 - - - - 17.5 - - - " SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-GREAT ROOM PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.2 0.995 PL 30.00 PF 10.3 1 0.0 SRCE 56.8 (N/A) 12.9 150 FTG TLG PE 0.0 2 0.0 0.0 46.5 0.0 0.254 TL 40.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 46.5 0.0 4.0 psi, 31.2 gpm 2A 0.0 0.0 42.5 0.01 Pipe: 3 31.2 1.590 FL 40.00 PF 1.3 2A 0.0 0.0 42.5 0.0 5.0 150 FTG 4L FE 0.0 3A 0.0 H.S. 41.1 5.0 0.026 TL 52.00 PV Pipe: 4 26.2 1.265 PL 10.00 PF 2.1 3A 0.0 H.S. 41.1 5.0 6.7 150 FTG T3LC PE -0.2 3 0.5 0.0 38.9 0.0 0.057 TL 36.00 PV Pipe: 5 26.2 1.049 PL 3.00 PF 1.7 3 0.5 0.0 38.9 0.0 9.7 120 FTG C FE -1.3 4 3.5 0.0 35.8 0.0 0.215 TL 8.00 PV Pipe: 6 26.2 1.101 FL 20.50 PF 4.0 4 3.5 0.0 35.8 0.0 8.8 150 FTG ET3R FE -3.0 5 10.5 0.0 28.8 0.0 0.112 TL 35.50 PV Pipe: 7 26.2 1.101 PL 1.50 PF 0.7 5 10.5 0.0 28.8 0.0 8.8 150 FTG T FE 0.0 6 10.5 0.0 28.1 0.0 0.112 TL 6.50 PV Pipe: 8 26.2 1.101 FL 13.00 PF 3.0 6 10.5 0.0 28.1 0.0 8.8 150 FTG ET2R FE -5.0 7 22.0 0.0 20.1 0.0 0.112 TL 27.00 PV Pipe: 9 26.2 1.101 FL 0.50 PF 0.6 7 22.0 0.0 20.1 0.0 8.8 150 FTG T FE 0.0 8 22.0 0.0 19.5 0.0 0.112 TL 5.50 PV Pipe: 10 26.2 1.101 PL 33.00 PF 6.2 8 22.0 0.0 19.5 0.0 8.8 150 FTG E2T5R FE 0.0 9 22.0 0.0 13.3 0.0 0.112 TL 55.00 PV Pipe: 11 26.2 1.101 PL 20.50 PF 3.9 9 22.0 0.0 13.3 0.0 8.8 150 FTG ET2R PE 0.0 10 22.0 0.0 9.4 0.0 0.112 TL 34.50 PV Pipe: 12 13.2 1.101 FL 0.50 PF 0.2 10 22.0 0.0 9.4 0.0 4.5 150 FTG TR FE 0.2 bA 21.5 4.3 9.4 13.2 0.032 TL 6.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-GREAT ROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT)- SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 13.0 1.101 PL 10.50 PF 0.5 10 22.0 0.0 9.4 0.0 4.4 150 FTG TR PE 0.2 hA 21.5 4.3 9.1 13.0 0.031 TL 16.50 PV Pipe: 14 0.0 1.101 PL 19.00 FF 0.0 8 22.0 0.0 19:5 0.0 0.0 150 FTG 3R PE 0.0 12 22.0 0.0 19.5 0.0 0.000 TL 22.00 PV Pipe: 15 1 0.0 1.101 FL 45.50 PF 0.0 12 22.0 0.0 19.5 0.0 0.0 150 FTG 2E4TR FE -2.2 13 27.0 0.0 17.3 0.0 0.000 TL 80.50 PV Pipe: 16 0.0 1.101 FL 4.00 FF 0.0 13 27.0 0.0 17.3 0.0 0.0 150 FTG ETR FE 0.2 13A 26.5 0.0 17.5 0.0 0.000 TL 17.00 PV Pipe: 17 0.0 1.101 FL 7.00 FF 0.0 13 27.0 0.0 17.3 0.0 0.0 150 FTG ER FE 0.2 14A 26.5 0.0 17.5 0.0 0.000 TL 15.00 PV NOTES (HASS) Calculations were performed by the HASS 8.0 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.102 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE:. 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-GREAT ROOM PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00. 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/11/2009 C:\HASS74\C4211-REV.SDF JOB TITLE: OAK AVE. LOT #2 TWO HEAD CALC-GREAT ROOM WATER SUPPLY ANALYSIS Static: 85.00 psi Resid: 81.00 psi Flow: 500.0 gpm 100.0 LEGEND 1 80.0 Available pressure 84.98 psi @ 31.2 gpm G A U G E 60.0 2 P R E S 40.0 S U R E Required pressure 56.77 psi @ 31.2 gpm Source Supply Curve System Demand Curve 20.0 p S i an -14.71 1 I 1 1 I I I I I 20C300 400 500 600 700 800 900 1000 FLOW (GPM) - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/11/2009 'H C:\HASS74\C4211-REV.sDF - JOB TITLE OAK AVE LOT #2 TWO HEAD CALC-GREAT ROOM WATER SUPPLY CURVE 96+ 88+ *\\\\\\\\ O \\\\\\\\\ I * <-81.0 psi @ 500 gpm 80+ Flow Test Point 72+ P 64+ R I E S I S 56X U I R I E 48+ ( I P I S I 40+ 32+ 24+ 16+ LEGEND 'I I X = Required Water Supply 56.77 psi @ 31.2 gpm 8+ I 0 = Available Water Supply I 84.98 psi @ 31.2 gpm U + ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GEM) A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpni/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2.1/2" (13mm) Total adjustment. Push-On/Thread-Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Bulletin 006 Rev.A Model RFC43 Concealed T. Residential Sprinkler (SIN RA0612) Product Description Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and 1/2' (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 13D The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43, for residential installations, uses a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler Thc Palinhia Aiutnmit, cnrinkIr (n Inr' '2's f'Jrrth tA fliiøctcn tAnuurt \/'rnrn F\ItA, Yrrk 1ncc9 I - inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to )" (13mm) of adjustment Turn the cover clockwise until the flange is in contact with the ceiling. The optional push-on cover plate may require a final adjusting turn to contact the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment Temperature Rating I Sprinkler Cover Plate I Max. Ambient Tp. I 165°F/74°C 135°F/57°C 100°F/38°C Installation Data Thread Size inch (mm) K Factor Sprinkler Spacing Maximum Distance to Wall ft. (m) Minimum Distance between sprinkler ft. (m) Minimum Required Sprinkler Discharge Flow Press. gpm (Lpm) psi (bar) /2' (15mm) 4.3 12 x 12(3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8 (0.54) ½" (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63) Y2" (15mm) 4.3 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13(49) 1 9.1 (0.63) Y2" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18(68) '(79) 17.5 (1.21) ½"(lSmm) .4.3 20x20(6.0x6.0) 10 (3.05) 8(2.43) 21 23.8(1.64) Note: 1 bar = 100 Kpa Model RFC 43 Pendent Flat Concealed installed below Sloped Ceiling. Technical Data S _________ prinkler I coverpF Max. Thread Size I.- Temp. Rating I Temp. rating I..fkcLI.... Pressure ½"NPT(R½) Max.: Actual T Sprinkler1 Ambient Temp. - . K Factor (metric (Iqt (SlN) ax. IUstment)( Identification 1 3(61.4) __.L._Pf±1,2- I aDie i - 1kpp11uduu1l [1 7)ih_ Mm. Flow Per Sprinkler Head Pressure psi (bar) IJ.5( - Max. Slope of Pitch Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) 12x 12 (3 - Mm. Flow Per Sprinkler Head gpm(Lpm) Pressure bar 13 49) 13(49) 14 x 14 4.3 x 4,3 1 68 17.5 (1,21) 16x 16(4,9x4,9) . 18 17.5(1,2L. 13(49) 18 x 18 5,5 x 5,5 _j___________ 21(79) 20 x 20 6.1 x 6,1 ___....?1 (79) 2. Maintenance Model RFC43 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange having a [thread-on] [push-on] and thread-off design, allowing a 1/2" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is property located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006). Id Model RFC43 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 005 gprrvfl2. Sprinkler frame and deflector shall be of bronze frame construction having a ½' NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3 (62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (740C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On cover Cover Plate Finishes n Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome " Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 112' REDUCING E r •. - (66.7mm] 014. [58.7mm] 014 - HOLE IN CEILING CUP - 2 [50.8mm] MAX. IF FACE OFFflTING TO FACE OF CEILING - oh'If7'ISION : CEILING °!?±f UWA L ._J (,:7mJ -_[;:::J DOON ASSEM'BL r SPRINKLER COVER PLATE: 1/2" 112.7mm] ADJUSTMENT 3. Bulletin 136 Rev.O 11ableo Model F1 FR Model FIFR Recessed Quick Response Sprinklers Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council ([PC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler Upright Pendent Vertical Sidewall Conventional UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1 FIR Vertical Sidewall Sprinklers. Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F 1 FR and 'P Recessed automatic spru iklcrs utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers This quick response enables the Model F1FR and F1FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists ol an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule this glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures. the glass bulb contains the Iluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble As heat is applied, the liquid ex- Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Conti nued heating forces the liquid tO push Out against the huh causing the glass to siattor opening the waterway ann allowing the deflector to (J51f'0- ute the discharging watc:r Application Quick response sprurocs are used in fixed lire pro!:'..' tion systems: Wet, Dry. Deuge or Preaction. Care must no exercised that the orifice ze. temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Aso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Conventional Model FIFR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench cfIIf1,,i flt Sprinkler Type K Factor - - - Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US Metric Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position ) (15mm) Standard Orifice with )" NPT (R/2) Thread 5.6 80 27(56mm) 1,2,3,45.6.7 R3625t '; (20mm) Large Orifice with ' NPT (R3/4)Thread 8.0 115 2.3" (58mm) 1,2,3,4.7.8 R36220) R3612 (17mm) Small Orifice with , NPT (R.) Thread 4.2 60 2.2"(56mm) 1,2,8 R3623W R3613 3/i" (10mm) Small Orifice with X" NPT (R})Thread 2.8 40 22(56mm) 1,2,8 R362 1W R3611 10mm Orifice XLH with R%"Thread 1 4.2 60 1 56mm 4.6,7 R3624 R3614 Conve ional-Install in Upght 0 Pendent Posion 10mm Orifice XLH With RN Thread 4.2 60 56mm --- R3674 15mm Standard Orifice with ; NPT (R,t') Thread 5.6 80 56mm 4.6,7 R3675 20rnm Large Oriflcewith~" NPT (R34)Thread 8.0 115 58mm 4,7 R3672 Polyester coated uririQht UL and ULC listed corrosion resistant. Upright Pendent Model FIFR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal - Orifice Thread Size K Factor Sprinkler Height Approval"'Sprinkler Organizations Identification Number (SIN) US Metric (20mm) NPT (R/2) " NPT (R3/4) 5.6 80 8.0 115 2.2- (56mm) 2.3" (58mm) 1.2.3.4.5,7.8 1.2,3.8 R3615 R3612 (1 1mm) Porn 10mcn ." NPT (R'/?) 4.2 . 60 28 40 4.2 60 I 2,2- (56mm) 12.8 83613 R3611 H 83614 - J NPT (R½) - 1.2.8 [ 56mm 4.7 __________ Refer to escutcheon data table tor approvals and dimensions '( O - H- H I/Nit I'0.4 cAI/....'q(0 socs I - .cc .,. ) co 1'/JI' O,l. — J6cCO I_f () Rfi'ft ifi r, & i'i (ccurc,,0'o,t ,.r. i/( foR ,,.PPROtNIS AA10 r' RIFE" '0 rI £ ¶0)'I'' 3.''J'4"E'C" 4'I'4'JV4j 0vtnS 2. Vertical Sidewall US Patent No. 6,374,920 ---- 4' -.- 4. Model FIFR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric 1/2'NPT(R'/2) 5.6 80 2.2" (56mm) 1,2,3,6,8 R3685 15mm 4NPT(RV2) 5.6 80 2.2" (56mm) 4 (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling I Dimension (Mm. - Max.) Upright 4" - 12 (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) Model FIFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Number (SIN) Light Ordinary Orifice Size US Metric Length Hazard j Hazard .1 (15mm) " NPT(RV). 5.6 80 2.63"(67mm) 1,2,3.5,8 1.2.5.8 R35 NOTE: UL. ULC and MEA Listing permits use with F 1 or F2 recessed escutcfleon. .l OF FIT1iRI TC) ---h WILL OIMFNS'ON "OLE 01k '2 REDUCER ._..J AY - 2) 2P 4 -t - UNTIL OLLAR 1'G'i ,CAlN5r SPRINKLER I WRENCH BOSS - 4LJOSTUENT (I) REFER TO EscurHcEoN DATA TABLE FOR APPROVALS AND 01VEWS10N. Horizontal Sidewall 3. Installation . :. .., Quick response sprinklers are intended for installation as specified inNFPA 13, FM Global Loss' Prevention Data Sheet 2-8N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will veld all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Tern rature Max. Ambient Temp. Bulb color -- c E Ordinary 57 135 1°F(38"C) Orange Ordinary 68 155 100°F(38c) Red Intermediate 79 175 150-F (66-C) Yellow Intermediate 93 200 150-F (66-C) Green High 141 266 225°F(107°C) Blue P1 Not available for recessed sprinklers. Escutcheon Data Escutcheon 'A" Face of Fitting Model Approvals i54tIment DSkX to Ceding or Wad Den Fl 1.2.4,8 Max Recess (38.1mm) Min Recess 3/" (5mm-24rni) (19.1mm) ty' F2 1,2,3,4.5, 7.8 Max Recess (38.1mm) ;6-- 16 Min Recess 3/6 (&nm - l7rrrn) (24mm) FP 1.2 Max Recessed lç(38.1mm) ______ _______ (11mm) _______ Push 5/ ' Thread-off 1,2 Mm Recessed '6 1.4rriii) __ No Dimensional Figure for EP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any. sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW'I Finishes (11 (21 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated (4) White Painted Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint 011 White Ott White Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult the factory for details. 121 FM Approvals is limited to bronze and brass, chrome or black plated finishes only. (3) FP Push -on/Thread-off escutcheon. (3) UL and ULC listed corrosion resistance. SIN numbers: R362 1. R3622, R3623. R3625. Note: For ,3'" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in iNs bulletin is lobe installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances wh000vcr applicable Products manufactured and distributed by Reliable have been protecting fife and property for over 80 years. and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the united States. Canada and foreign countries. -- -- Manufactured by Reliabld The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848.6051 Sates Fax (914)829-2042 Corporate Offices ww.re4iabspei'ikle(.c6Yt1 Internet Address i: Rocydcii /Papw Revision lines indicate updated or new data CC Pnritect in USA 3,07 P,N9999970027 Upright Vertical Sidewall Pendent Conventional n liabl The Designer® Model Fl Sprinkler Standard Upright Standard Pendent Extended Coverage Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW1 Deflector The Designer®ll Model Fl Recessed Sprinkler Recessed Pendent Recessed Extended Coverage Pendent Approval Organizations Underwriters Laboratories Inc. Underwriters' Laboratories of Canada Factory Mutual Research Corp. Loss Prevention Council NYC BS&A No. 587-75-SA Pleniere Assemblee Verband der Schadenversicherer NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open (VNlV) Patents: U.S. Patent No. 6,374,92 Applies to Model Fl Vertical Sidewall Sprinklers. Product Description The El Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low prof le of a decorative sprinkler. Whether installed on exposed piping or in an office ceiling, It is functional and attractive. The Horizontal and Vertical SidewaH Sprinklers provide an equally attractive appearance when ceiling piping cannot be used. Beautifully versatile is the description for the Reliable Model Fl Recessed Designer glass bulb sprinkler. Recessing The Designer® enhances its already low profile decorative appearance, and facilitates a rapc and perfect installation. Model El Recessed Designers escutcheon is highly adjustable. The two piece construction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus facilitating maintenance of above ceiling services. The Designer® Automatic Sprinkler utilizes a frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside of a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Bulletin 117 Ray.S Model Fl Model Fl Recessed Standard Response Sprinklers Horizontal Sidewall Recessed Pendent _ "[I Extended Coverage Recessed Extended Pendent Coverage Pendent At normal temperatures, the glass bulb contains (ho fluid in both the liquid phase and in the vapor phase The vapor phase can be seen as a small bubble As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The Fl Sprinkler temperature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York, 10523 a -S Model Fl Upright, Pendent & Conventional Sprinklers Installation Wrench: Model 0 Sprinkler Wrench Upright Pendent Conventional Installation Data: Sprinkler Identification Numbers Nominal Nominal K Factor Sprinkler Approval Orifice Thread Size :-i Height Organization US Metric Upnght Pendent - Standard-Upright (SSU) and pondont Deflectors Marked to Indicate Position 56 80 1234567 R17254 01715 '15mm) 17/32' 1W NPT 80 115 1,2.3.4.7,8 — 01722"' 01712 (0(flffl) — - 56 80 (15mm)m - (R 2) --- (56mm) - ---------------------- 1 7!32 NOT 80 1 (20mmY (83/4) 7/16'7, rsipl 42 130 22 -- - 1 28 01723' ii '13 (11mm) (R1/2) 56mm) -- 28 -40 - 1.28 - -------------- -- 10mmXLH 03/8 4.2 60 56 lfliifl 4.6.7 01724 01714 Convenncnai - I oman in Uprqnl or -'rriideol Position 0mrnXLH 03/8 4 2 60 561mm 01774 5mm NPT 5.6 80 SIt 1rem 467 01775 20mm 80 115 58 lOin 4 7 . 01772 LPC Approval up to 286°F (141°C) FM Approval for SSU up to and including 200°F (93°C) only. (F1S5) VdS Approval for Intermediate Response 155°F (68°C) only Polycoated upright UL and ULC listed corrosion resistant. 2. Model Fl Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench - 2 1/4' HOLE ON.— I I5/I6 014 (492nmJ - $ r I/i RL0L11R TURN COLLAR — [234nm X 127-1 UNTiL T$CJIT AGAINST SPRINKLER *1RuNCH BOSS L J I 314' ADJUSTMENT 1 ': II7TGOIA 227/32 O'& (7z2,) I VI IUl It (1) When installed directly into a tee, the escutcheon dimensions adjustment will be reduced. Installation Data: NaI Orifice ht Thread S - . Nominal us K Factor Metric Sprinkler Heig Organization Approval 1.2,3,4.5.7 Sprinkler on Numbers (SIN) R 1715 (15mm) 56 1 80 17/32" 314• NPT 80. 115 2.3' 1,2.3.4.8 (58mm) p1712 (20mm) (P3/4) VY (15mm)"1 ½" NPT (P1/2) 56) 80 (56mm) 2.2" 7 17/32 1/4" NPT 80 115 2.3' (R3/4) .L .............. 7/16' 1/2' NPT 42 2.2' 128 P1713 .._!?L_ _.._L1 3/8' (10mm) /1 NPT (R1/2) 28 . 0 2.2" (56mm) L..... 1,2.8 1711 10mm P3/8 42 60 56.1mm 4.7 01714 (2) FM Approval Light Hazard - No Limitations Ordinary Hazard - Groups 1 & 2, Wet Systems only. LPC Approval is for 57°C through 93°C ratings. VdS Approval for Intermediate Response 155F (68°C) only. CI Model Fl Vertical Sidewall Sprinkler Installation Wrench: Model 0 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector o Ceiling Distance Pendent 4 (102mm) - 12 (305mm) Vertical Sidewall Installation Data: Nominal K Factor . Sprinkler Sprnkler Approval Nominal Orifice Thread Size US Height Organizations kientification Metric Numbers (SIN) /2(15mm) V NPT (P1/2) 5.6 j 8.0 1 2.2' (56.1mm) 1.2,3.46,8 P1785 (1) LPC Approval is pendent only, 57°C through 141°C ratings. Model Fl Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Horizontal Sidewall Installation Data: Nominal K Factor Approval Organizations Sprinkler Nominal .............................. 'H Sprinkler ......--.-- ................... Thread i Ordinary identification S , Office us ' Metric I Height Light Hazard Hazard Numbers (SIN) /(i5mm) 5.6 80 2.6Y(67mm) 1,2,3.5 1.2,5(R 112p) i . P1735 Note: UL and ULC Listing permits use with Fl escutcheons, light hazard only. 4. Model Fl Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model D Sprinkler Wrench Approval Type: Extended Coverage - Light Hazard Occupancy Coverage Area Pressure Flow Rate Width x Length Max. Area Nominal K=8.0 (115) K=5.6 (80) psi bar I psi bar ftxft7mxm 26 98.4 10.6 I 0,7 I 21.6 . 1,5 16 x 16 4.9 x 4.9 33 125.0 17.0 I 1,2 I 34.7 2.4 18 x 18 I 5.5 x 5.5 40 151.4 1 25,0 1,7 51.0 3,5 1 20x20 60x60 Installation Data: PI Extended Coverage Pendent Nominal Thread Orifice Size Nominal K Factor Sprinkler Height Approval . _Temperature Organizations OF Rating Sprinkler OC Numbers US - Metric _...L_ _.1_ m ffL 1.2.8 57.68 R1742 5.6 1,2,8 135. 155 57, 68 Ri 745 '/2' (15mm) 80 2.2 (56mm) Model Fl Recessed Extended Coverage Pendent Sprinkler Deflector: [C Pendent Installation Wrench: Model GFR1 Sprinkler Wrench Approval Type Extended Coverage Light Hazard Occupancy - Extended Coverage Recessed (1) When nstalled directly into a toe, the escutcheon dmension's adjustment will be reduced. Coverage Area Pressure Max. Area Flow Rate Nominal .' Width xLength K=8.O (115) K=5.6 (80) gprn Urnin psL 'f bar - psi , bar , ft. xft. rnxrn 26 . 984 10.6 0.7 216 1.5 16 16 49 x 49 33 1250 170 1,2 347 24 18x18 ' 55x55 40 1514 25.0 1.7 510 3 20x20 6.0x60 lntIItinn r-lintq. Nominal Thread Nominal K Fact Sprinkler Approval . Temperature Rating Sprinkler Identification Orifice . Size - Metric US NPT Height Organizations F "C j_Numbers (SIN) (R3/4) 17/32' 3/V . 2256mm 1.2,8 5155 57.68 P1742 --- L20mm) 5.6 W (15mm) 80 2 2' (56mm) 1.2.8 135.155 57.68 Ri 745 5. Model Fl & Fl Recessed Sprinklers Application Model Fl and Fl Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Installation Model Fl sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model Fl Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model El Escutcheon illustrated is the only recessed escutcheon to be used with the Model Fl Pendent and EC Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl Recessed Pendent and EC Pendent Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange covers to protect the bulb during the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Maintenance The Models Fl and Fl Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Finish (where applicable) Temperature Ratings Classification Sprinkler Temperature Maximum Ambient Temperature Bulb Color ° 1_°c °F Ic Ordinary 135 1 57 100 38 Orange Ordinary 155 68 100 38 Red intermediate 175 79 150 66 Yellow intermediate 200 93 150 66 Green High 1 286 141 225 107 1 Blue Extra High1'1 1 360 1 182 300 1 149 1 Mauve (1) Not Available for Fl Recessed Patents: U.S. Patent No. 6,374,920 Applies to Model Fl Vertical Sidewall Sprinklers. Finishes Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome chrome White Polyester Coated(3)11) - White Painted Special Application Finishes Sprinkler - Escutcheon 8ng10 Brass"' Bright Brass Biack Plated Biack Plated Biack Paint°1 Black Paint Off While` Off White Satin Chrome Satin Chrome Lead Platcd°341 Wax Coated"""' Wax Over Lead13 4X5) Other colors and finishes are available on special order, Consult factory for details. 200°F (93°C) maximum. UL and ULC listed, and NYC approved only. 155°F to 200°F (68°C to 93°C) ratings only. 286°F (141,C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). UL and ULC listed corrosion resistant SIN numbers R1721, R1722, P1723 and P1725. Note: For 1/2 orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 013. The eQuipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. # Recycled Paper fleliablim (800) 431-1588 Sales Offices (914) 829-2042 Corporate Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data w.reFabiesprinkier.com Internet Address E.G. Printed in U.S .A. 3,107 P/N 9999970011