Loading...
HomeMy WebLinkAbout1208 OAK AVE; ; AS090138; PermitJob Address: 1208 OAK AV Permit Type: SPRINK Parcel No: 1561804900 Lot #: 0 Status: ISSUED Applied 11/3/2009 Approved: 11/3/2009 7/19/22, 5:30 PM AS090138 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090138 Reference No.: Issued: 11/3/2009 PC #: Inspector: Project Title: 1208 & 1210 OAK AV TWO FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: INNOVATIVE FIRE PROTECTION SUITE 101 8779 COTTONWOOD AV SANTEE, CA (619) 593-8200 (619)593-9133 Owner: BUSBY FAMILY TRUST 10-26-01 1212 OAK AVE CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 S SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/21/2009 C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 88.0 82.0 500.0 88.0 31.1 66.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 10.0 SOURCE 66.8 31.1 2 10.0 - - - - 53.7 2A 10.0 - - - - 49.7 - - - 3A 0.0 HOSE STREAM 48.9 5.0 3 0.5 - - - - 46.2 - - - 4 3.5 - - - - 43.2 - - - 5 10.5 - - - - 37.8 - - - 6 10.5 - - - - 32.8 - - - 7 20.5 - - - - 24.3 - - - 8 20.5 - - - - 23.0 9 30.5 - - - - 12.1 - - - 10 30.5 - - - - 9.6 - - - 10A 30.0 K= 4.30 9.1 13.0 11 30.5 - - - - 9.6 - - - hA 30.0 K= 4.30 9.3 13.1 12 20.5 - - - - 23.6 - - - 12A 20.0 - - - - 23.8 - - - 13 20.5 - - - - 23.6 - - - 13A 20.0 - - - - 23.8 - - - These 7ve ...;etire\;%vetl;rappalttit cortipitance with the current applicable codes and standards tn fotce ii the urisdict100 The owl1 or cOflta°1 may uttlt/e i ,in, es ic n ill pp of an app11catt00 101 a building pci Oil h o o the espresfi derstaodtt1g that this teVte\V in ii, elieveS the owflel 01 contraLtfh or their ...itI ettnitte or archttC for sole respotmtbtlt(Y mr tull cotflPl ance with sad codes attd siandit 5' miteIudit the hui1d111g code or for any 'e"'" e5p nsibtltY or dcIILiCitctC eIrlS. OUU1S5 negligence in plans whether or nist noted in this review. I )ate/Q"7 Reviewer 1,71 RECOMMEND APPROVA%. Lai 0 KFCOMMENDA'RO SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/21/2009 1 C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.1 0.995 PL 40.00 PF 13.1 1 10.0 SRCE 66.8 (N/A) 12.9 150 FTG T2LG FE 0.0 2 10.0 0.0 53.7 0.0 0.253 TL 52.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 10.0 0.0 53.7 0.0 4.0 psi, 31.1 gpm 2A 10.0 0.0 49.7 0.0 Pipe: 3 31.1 1.590 PL 165.00 FE' 5.1 2A 10.0 0.0 49.7 0.0 5.0 150 FTG E9L FE 4.3 3A 0.0 H.S. 48.9 5.0 0.026 TL 198.00 PV Pipe: 4 26.1 1.265 FL 10.00 FE' 2.5 3A 0.0 H.S. 48.9 5.0 6.7 150 FTG E2TC FE -0.2 3 0.5 0.0 46.2 0.0 0.057 TL 44.00 PV Pipe: 5 26.1 1.049 PL 3.00 PF 1.7 3 0.5 0.0 46.2 0.0 9.7 120 FTG C FE -1.3 4 3.5 0.0 43.2 0.0 0.213 TL 8.00 PV Pipe: 6 26.1 1.101 FL 11.50 FE' 2.3 4 3.5 0.0 43.2 0.0 8.8 150 FTG E2R FE -3.0 5 10.5 0.0 37.8 0.0 0.112 TL 20.50 PV Pipe: 7 26.1 1.101 PL 16.50 PF 5.1 5 10.5 0.0 37.8 0.0 8.8 150 FTG 2E3T PE 0.0 6 10.5 0.0 32.8 0.0 0.112 TL 45.50 PV Pipe: 8 26.1 1.101 FL 14.00 FE' 4.1 6 10.5 0.0 32.8 0.0 8.8 150 FTG 3E2R FE -4.3 7 20.5 0.0 24.3 0.0 0.112 TL 37.00 PV Pipe: 9 20.5 1.101 FL 12.00 PP 1.4 7 20.5 0.0 24.3 0.0 6.9 150 FTG T2R PE 0.0 8 20.5 0.0 23.0 0.0 0.071 TL 19.00 Pv Pipe: 10 26.1 1.101 FL 27.50 PP 6.5 8 20.5 0.0 23.0 0.0 8.8 150 FTG 3ET5R PE -4.3 9 30.5 0.0 12.1 0.0 0.112 TL 58.50 PV Pipe: 11 11.1 1.101 FL 68.00 PP 2.5 9 30.5 0.0 12.1 0.0 3.7 150 FTG 4ET9R FE 0.0 10 30.5 0.0 9.6 0.0 0.023 TL 110.00 PV Pipe: 12 13.0 1.101 FL 8.00 PP 0.6 10 30.5 0.0 9.6 0.0 4.4 150 FTG ETR FE 0.2 10A 30.0 4.3 9.1 13.0 0.031 TL 21.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/21/2009 C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -1.9 1.101 PL 9.50 FE 0.0 10 30.5 0.0 9.6 0.0 0.6 150 FTG R PE 0.0 11 30.5 0.0 9.6 0.0 0.001 TL 10.50 PV Pipe: 14 13.1 1.101 FL 3.50 PF 0.5 11 30.5 0.0 9.6 0.0 4.4 150 FTG 2TR PE 0.2 hA 30.0 4.3 9.3 13.1 0.031 TL 14.50 PV Pipe: 15 -15.0 1.101 FL 47.00 FE' 2.5 11 30.5 0.0 9.6 0.0 5.1 150 FTG 2T6R FE 0.0 9 30.5 0.0 12.1 0.0 0.040 TL 63.00 PV Pipe: 16 -5.6 1.101 FL 72.00 PF 0.7 8 20.5 0.0 23.0 0.0 1.9 150 FTG 4T9R FE 0.0 12 20.5 0.0 23.6 0.0 0.007 TL 101.00 PV Pipe: 17 0.0 1.101 FL 7.50 PF 0.0 12 20.5 0.0 23.6 0.0 0.0 150 FTG 2ETR FE 0.2 12A 20.0 0.0 23.8 0.0 0.000 TL 27.50 PV Pipe: 18 -5.6 1.101 FL 1.00 FE' 0.0 12 20.5 0.0 23.6 0.0 1.9 150 FTG ---- FE 0.0 13 20.5 0.0 23.6 0.0 0.007 TL 1.00 PV Pipe: 19 0.0 1.101 PL 2.00 PF 0.0 13 20.5 0.0 23.6 0.0 0.0 150 FTG ETR FE 0.2 13A 20.0 0.0 23.8 0.0 0.000 TL 15.00 PV Pipe: 20 -5.6 1.101 PL 85.00 FE 0.7 13 20.5 0.0 23.6 0.0 1.9 150 FTG 4T FE 0.0 7 20.5 0.0 24.3 0.0 0.007 TL 105.00 PV NOTES (HASS) Calculations were performed by the HASS 8.0 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.030 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/21/2009, C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM (4) PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 0 44 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/21/2009 C:\HASS74\C4211—L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC—REC ROOM 0 0. 00 WCl 0OU D I.i a) D " • H D J_) -i a) Ow 04 'J Z o0Ow ill a) .1 00) 4 r-1'.D-.-10>, a% 0cCflU) >r- afl.O CQ co rn 0 0 0 0 0 0 • • . o 0 0 0 0 0• 0 co W 010Cll 0.cNU)U)DCII '-0.U)-H-- 0 -1 0 0 0 0 0 co SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/21/2009 : C:\HASS74\C4211-L3.SDF JOB TITLE:OAKAVE. LOT :fl TWO HEAD CALC-REC ROOM: - WATER SUPPLY CURVE 96+ 880\\\\\ I \\\\\\ \\\\\\ * <-82.0 psi @ 500 gpm 80+ Flow Test Point 72+ x P 64+ R E I S I S 56+ U I R I E I 48+ ( I P S I IL 40+ 32+ 24+ 4 16+ LEGEND I, X = Required Water Supply 6680 psi @ 31.1 gpm 8+ 'I I 0 = Available Water Supply I 87.96 psi @ 31.1 gpm + ------+ --------+ ------------------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) -'. --•,,,, ',,- • SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/21/2009 C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE - PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 88.0 82.0 500.0 88.0 31.3 56.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1 31.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 10.0 SOURCE 56.0 31.3 2 10.0 - - - - 42.8 2A 10.0 - - - - 38.8 3A 0.0 HOSE STREAM 38.0 5.0 3 0.5 35.3 4 3.5 - - - - 32.2 5 10.5 - - - - 26.9 - - - 6 10.5 - - - - 21.8 - - - 7 20.5 - - - - 13.3 - - - 8 20.5 - - - - 12.7 - - - 9 30.5 - - - - 8.4 10 30.5 - - - - 8.4 - - - 10A 30.0 - - - - 8.6 - - - 11 30.5 - - - - 8.4 - - - hA 30.0 - - - - 8.6 - - - 12 20.5 - - - - 9.8 - - - 12A 20.0 K= 4.30 9.1 13.0 13 20.5 - - - - 9.8 - - - 13A 20.0 K= 4.30 9.5 13.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/21/2009, C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) FIW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.3 0.995 PL 40.00 PF 13.2 1 10.0 SRCE 56.0 (N/A) 12.9 150 FTG T2LG FE 0.0 2 10.0 0.0 42.8 0.0 0.254 TL 52.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 10.0 0.0 42.8 0.0 4.0 psi, 31.3 gpm 2A 10.0 0.0 38.8 0.0 Pipe: 3 31.3 1.590 FL 165.00 PF 5.1 2A 10.0 0.0 38.8 0.0 5.1 150 FTG E9L FE 4.3 3A 0.0 H.S. 38.0 5.0 0.026 TL 198.00 PV Pipe: 4 26.3' 1.265 FL 10.00 FE' 2.5 3A 0.0 H.S. 38.0 5.0 6.7 150 FTG E2TC FE -0.2 3 0.5 0.0 35.3 0.0 0.057 TL 44.00 PV Pipe: 5 26.3 1.049 FL 3.00 PF 1.7 3 0.5 0.0 35.3 0.0 9.7 120 FTG C FE -1.3 4 3.5 0.0 32.2 0.0 0.215 TL 8.00 PV Pipe: 6 26.3 1.101 FL 11.50 PF 2.3 4 3.5 0.0 32.2 0.0 8.8 150 FTG E2R FE -3.0 5 10.5 0.0 26.9 0.0 0.113 TL 20.50 PV Pipe: 7 26.3 1.101 PL 16.50 FE' 5.1 5 10.5 0.0 26.9 0.0 8.8 150 FTG 2E3T FE 0.0 6 10.5 0.0 21.8 0.0 0.113 TL 45.50 PV Pipe: 8 26.3 1.101 FL 14.00 FE' 4.2 6 10.5 0.0 21.8 0.0 8.8 150 FTG 3E2R FE -4.3 7 20.5 0.0 13.3 0.0 0.113 TL 37.00 PV Pipe: 9 12.7 1.101 FL 12.00 PF 0.6 7 20.5 0.0 13.3 0.0 4.3 150 FTG T2R FE 0.0 8 20.5 0.0 12.7 0.0 0.029 TL 19.00 PV Pipe: 10 0.0 1.101 FL 27.50 FE' 0.0 8 20.5 0.0 12.7 0.0 0.0 150 FTG 3ET5R FE -4.3 9 30.5 0.0 8.4 0.0 0.000 TL 58.50 PV Pipe: 11 0.0 1.101 FL 68.00 PF 0.0 9 30.5 0.0 8.4 0.0 0.0 150 FTG 4ET9R FE 0.0 10 30.5 0.0 8.4 0.0 0.000 TL 110.00 PV Pipe: 12 0.0 1.101 PL 8.00 PF 0.0 10 30.5 0.0 8.4 0.0 0.0 150 FTG ETR PE 0.2 10A 30.0 0.0 8.6 0.0 0.000 TL 21.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/21/2009 C:\HASS74\C4211-L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 0.0 1.101 PL 9.50 PF 0.0 10 30.5 0.0 8.4 0.0 0.0 150 FTG R PE 0.0 11 30.5 0.0 8.4 0.0 0.000 TL 10.50 PV Pipe: 14 0.0 1.101 PL 3.50 PF 0.0 11 30.5 0.0 8.4 0.0 0.0 150 FTG 2TR PE 0.2 hA 30.0 0.0 8.6 0.0 0.000 TL 14.50 PV Pipe: 15 0.0 1.101 PL 47.00 PF 0.0 11 30.5 0.0 8.4 0.0 0.0 150 FTG 2T6R PE 0.0 9 30.5 0.0 8.4 0.0 0.000 TL 63.00 PV Pipe: 16 12.7 1.101 PL 72.00 PF 2.9 8 20.5 0.0 12.7 0.0 4.3 150 FTG 4T9R PE 0.0 12 20.5 0.0 9.8 0.0 0.029 TL 101.00 PV Pipe: 17 13.0 1.101 PL 7.50 PF 0.8 12 20.5 0.0 9.8 0.0 4.4 150 FTG 2ETR PE 0.2 12A 20.0 4.3 9.1 13.0 0.031 TL 27.50 PV Pipe: 18 -0.3 1.101 PL 1.00 PF 0.0 12 20.5 0.0 9.8 0.0 0.1 150 FTG ---- PE 0.0 13 20.5 0.0 9.8 0.0 0.000 TL 1.00 PV Pipe: 19 13.3 1.101 FL 2.00 FE' 0.5 13 20.5 0.0 9.8 0.0 4.5 150 FTG ETR FE 0.2 13A 20.0 4.3 9.5 13.3 0.032 TL 15.00 PV Pipe: 20 -13.6 1.101 FL 85.00 FE' 3.5 13 20.5 0.0 9.8 0.0 4.6 150 FTG 4T PE 0.0 7 20.5 0.0 13.3 0.0 0.033 TL 105.00 PV NOTES (HASS) Calculations were performed by the HASS 8.0 computer program under license no. 16080621 granted by I-IRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.008 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/21/2009 C:\HA5S74\C4211-L3.sDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC-REC ROOM (4) PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) B T L C B G A D Eli Tee 1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 1-4 0 0 00 0 0 LI) 0 0 ,31 0 rn 0 0 0 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/21/2009 C:\HASS74\C4211—L3.SDF JOB TITLE: OAK AVE. LOT #3 TWO HEAD CALC—REC ROOM 0 0 H (N 0 0 0 0 0 0 • • • • • H 0 0 0 0 0 0 0 (N -H Ci)0Lr —O&)-H--- - ---- --- ,-;-- ----.-- -:;--- - -- .-,- - - - -=.-- -. .- SPRINKLER SYSTEM;HYDRAULIC ANALYSIS Page 6 DATE 10/21/2009 C:\HASS74\C4211-L3.SDF -JOB-TITLE, OAK AVE. LOT #3 TWO HEAD-CALC-REC ROOM - - WATER SUPPLY CURVE 96+ I \\\\\\ \\\\\\ * <-82.0 psi @ 500 gpm 80+ Flow Test Point 72+ P 64+ R E I S I S 56X U I R I E I 48+ ( I P I S I 40+ 32+ 24+ 16+ LEGEND I X = Required Water Supply 56.03 psi @ 31.3 gpm 8+ I 0 = Available Water Supply I 87.96 psi @ 31.3 gpm + ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) L Bulletin 006 Rev.A ble A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2.112" (13mm) Total adjustment. Push-On/Thread-Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Model RFC43 Concealed Residential Sprinkler (SIN RA061 2) CD Product Description Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and 1/2 (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 13D. The RFC43 can reduce the need for precise cutting of drop nipples The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43, for residential installations, uses a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler Thc RchhIø hiOnmnfie qnrinklar ('rb Inr cc f\Irrth tA flu uctc'n PrktA,\, tArupnt \Icrncun NOW Yrrk incc inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5i8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to /2" (13mm) of adjustment Turn the cover clockwise until the flange is in contact with the ceiling. The optional push-on cover plate may require a final adjusting turn to contact the calling. Cover removal requires turning in the counter-clockwise direction. In callings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and calling and the 4 slots in the cup are all open and free from any air flow impediment Temperature Rating Sprinkler Cover Plate Max. Ambient Temp. 165°FR4°C 135°F/5C 100°F/38°C I Installation Data Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge Spacing Distance Distance between inch (mm) Factor ft. (m) to Wall ft. (m) sprinkler ft. (m) Flow Press. gpm (Lpm) psi (bar) 1/2' (15mm) 4.3 12 x 12 (3.60.6) 6(1.83) 8 (2.43) 12(45) 7.8 (0.54) l/2 (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63) 1/2" (15mm) 4.3 16 x 16 (4.9x4.9) 8(2.43) 8(243) 13(49) 9 1(0.63) '/2': (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(243) 18(68) 17.5 (1.21) ½"(l5mm) 4.3 20x20(6.0x6.0) 10(3.05) j8(243) 21(79) 23.8(1.64) Note: 1 bar = 100 Kpa Model RFC 43 Pendent Flat Concealed installed below Sloped Ceiling. Tkrrit flt Thread Sprinkler [Temp. Si I Temp. Rating I Temp. Rating Pri F kçL ½" NPT ( L IJZL I 135(57) -- lax. Max. Actual 1 Sprinkler ssure Ambientlemp. K Factor M Ad ' ti Identification Number J (bar) ._çL_... Jc 5(.) Table 3 - Anolication Max Sprinkler Spacing Along Slope (1 (W) Width x ( L) Length ft (m) Mm. Flow Per Sprinkler Head Pitch I Slope of' 18.4° Pitch Pressure I Mm. Flow Per Sprinkler Head Pressure 12 x 12(3,6 x 3,6) - L!15 (1,21) 13(49) 9.1 0.63_...j 14 x 14(4.3 x 4,3) 18(68)- 18(68)...__j L 17.5(1,21) 13(49) 9.1 0,63 -. 16 x 16(4.9 x 4,9) ITS (121) 13(49) 18 x 18(5.5 x 5,5) I 21(79) 20x20(6,1 x6,1) __________ 21 (79) 23.8 1,64 2. Maintenance Model RFC43 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (57°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange having a [thread-on] [push-on] and thread-off design, allowing a /2" cover plate adjustment Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006). Model RFC43 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gprrt2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3 (62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (740C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On cover Cover Plate Finishes n Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome " Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. - x 112 ' REDUCING TEE OR ELBOW -... C f (66.7mm] DA. 2?6 - (58.7mm] 0/A - •..- I-I0LE IN CEILING CUP 1 2 [50.8mm] U4X. FACE OF FITTING ro FACE OF CEILING 1-' DIMENSION CEILING' - [12.7mm] MAX. COVER ADJUSTMEJ .- DJA_ rE _[I COVER PLA (84.1mm] [4.8mm] ASSE/,I&LY SPRINKLER-' COVER PLATE, 1/2 ' (12.7mm] ADJUSTMENT 3. Ila*. ble Bulletin 136 Rev.O w Model FIFR Model FIFR Recessed Quick Response Sprinklers Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler Upright Pendent Vertical Sidewall Conventional UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the anractive low profile of a decorative sprinkler. The Models F 1 FR and F 1 1R Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response tines in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F 1 FR and F 1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is Specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble As heat is applied, the liquid ex- Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push Out against the bIb causing the glass to shatter, opening the waterway ann allowing the deflector to distrib- ute the discharging water Application Quick response sprinKers are used in fixed lire protec tion systems: Wet, Dry. Deiuge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Conventional H CJE R(OCf 4 ,&u',ST cP.'i( socc - —1 P rcc 01 70 wus1±'-- co r 21- ,/8 I 2 I1/32' N, [12.2,,..,,1 (') REFER ,o r r2 (sCu'C..(O LM r r( fog 4PPRO',4 S 4'O O44.5,OgS Model FIFR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench infIlfinn flith Sprinkler Type K Factor Sprinkler Height Approval Organization Sprinkler identification Number (SIN) US Metric Standard-Upright (SSU and Pendent (SSP) Defiectors Marked to Indicate Position )" (15mm) Standard Orifice with )" NPT (R,) Thread 5.6 1 80 2.2" (56mm) 1.2,3.4.5.6.7 R3625 R3615 ; (20mm) Large Orifice with 3" NPT (R3/4)Thread 8.0 115 2.3' (58mm) 1,2,3,4,7,8 8362201 83612 <' (17mm) Srnafi Orifice with )" NPT (R.) Thread 4.2 60 2.2" (56mm) 1,2,8 R3623t0 R3613 3" (10mm) Small Orifice with X" NPT (RY)Thread 2.8 40 2.2"(56mm) 1,2,8 R362 R361t l0mmOdfice)QHwfthR%"Thread 4.2 60 56nm 4,6,7 R3624 R3614 Conventional--Install in Upright cx Pendent Position ____ 10mm Orifice )QH with R Thread 42 60 56mm ---- R3674 15mm Standard Orifice with ) NPT(RX) Thread 5.6 56mm 4,6,7 I rnn Orifi with 3/4"NPT (R34)Thread 83675 20mm 8.0 4--807 11558mm 4,7 R3672 Polyester coated upright UL and ULC listed corrosion resistant. Upright Pendent Model FIFR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: P Nominal - Thread K Factor Sprinkler Approvat1° Sprinkler Identification Orifice Size Height Organizations Number (SIN) us Metric (15mm) "NPT(R'/2) 5.6 80 27(56mm) .2,3.4.5,7,8 R3615 (20mm) " NPT (R3%) 8.0 L)5 2.3" (58mm) 12,3.8 R3612 -- {T22L_ NPT(RY7) 4.2 60 27(56mm) 12.8 V (10mm) ;'NPT (R/2) 2.8 - 40 27(56mm) 1,2.8 R3611 10mm -R 4 4.2 - 60 56mm 4.7 83614 Refer to escutcheon data table for approvals and dimensions 2. Vertical Sidewall US Patent No. 6,374,920 3. 1 00 I f'EF''COR OtEDIA. 2-1 2 REDUCER __•7 I t 2 OLLAR UNTIL - r'c; .104/NSf SPRINKLER : WRENCH BOSS. - SruE,vr REFER To ESCUTHCEON DATA TARt C FOR APPROVALS AND DIMENSIONS '.t' '-1 L Horizontal Sidewall Model F1 FIR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Positlori Upright or Pendent Approval Type: Light Hazard Occupancy I ncfllfitn flf Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) __________ us Metric 1/2 NPT(RY2) 5.6 80 2.2(56mm) 1,23,6.8 R3685 15mm W'NPT(R½) 5.6 80 2.2(56mm) 4 LPC Approval is for Pendent position only. Orientation Deflector to Ceiling Dimension (Mm. - Max.) Upright 4" - 12 (102mm - 305mm) Pendent 6 - 12 (152mm .305mm) I Model FIFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Number (SIN) I Light Ordinary Orifice Size US Metric Length Hazard Hazard ic' (15mm) )'' NPT(R'/7) 5.6 80 263(67mm) 1,2,3.5.8 1.2.5.8 R3635 NOTE: UL. ULC and MEA Listing permits use with Fl Of F2 recessed escutcheon. H 1 OF F/TI/NO r ----H WALL DIMENSION .-. __J .. IJI, tie vacuuming. Remove an'sprinkier. which has: been painted (other than factory applied) 'ordàmaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes (1)121 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated (4) White Painted t31 Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome (I) Other finishes and colors are available on special order. Consult the factory for details. (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. 131 FP Push-on/Thread-off escutcheon. ( 4) UL and ULC listed corrosion resistance. SIN numbers: R362 1. R3622, R3623, R3625. Note: For )'" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: Sprinkler Mode) Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. -Installation -. Quick response spnnklers are intended for ,nstallaUon as specified hi NFPA 13, FM Global Loss PrêñtithDätaSbeét. 2-8N or. other applicable standards; ,Quick responsesprin- kters and standard response sprinklers should not be inter- mixed.' The Model Fl FIR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model F1FR Sprinklers, use the Model D 5pm- kier Wrench. When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RPSCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Sprinkler Clfficbon Max Ambient Temp.c PBuIb E Ordinary 57 135 1O3°F(38°C) Ordinary 68 155 ltfl°F(38"C) Intermediate 79 175 150F(66"C) Yellow Intermediate 93 2(K) 150°F(66C) Green High 141 286 1 225F(107°C) Blue Not available for recessed sprinklers. Escutcheon Data Escutcheon "A" Face of Fithng Model Approvals kment Drnenston to Ceding or Wad Dimension 1/2 Fl 12.4,8 Max Recess (38.1mm) i6 6 Min Recess X (5mm - 24mm) (19.1mm) 1/2 F2 1.2,3,4,5,7.8 Max Recess (38.1mm) 4" - Min Recess -' (5mm- l7rrni) (24mm) FP 1.2 Max Recessed X 6"1"(38.1m) ______ _______ (11mm) PuSh-orV Thread-off 1.2 Min Recessed 16 1" (25 4rrm) __ (24mm) __________ No Dimensional Figure for FP Maintenance The Models F1FR and FlEA Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation. or other similar Organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years. and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled (800)431-1588 Sales Offices Reliableo (800)848-6051 Sales Fax RevisiDn lines indicate updated or new data (914)829-2042 Corporate Offices ww.reliableslx 1klor.COhi Internet Address CC. Piinicd in U.S.A.3,V7 P/49999570027