HomeMy WebLinkAbout335 OAK AVE; ; AS060278; PermitPermit No: AS060278 Job Address: 335 OAK AV Permit Type: SPRINK Parcel No: 2032600400 Lot #: 0 Status: ISSUED Applied 11/17/2006 Approved: 11/17/2006 7/19/22, 5:25 PM AS060278 Permit Data City of Carlsbad Sprinkler Permit Reference No.: Issued: 11/17/2006 PC #: Inspector: Project Title: OCEAN MIST CONDOS FOUR FIRE SPRINKLER INSPECTIONS @ $62/EA Applicant: Owner: SEXTON FIRE PROTECTION OCEAN MIST L L C 5044 GLEN ST 343 OAK AVE CARLSBAD CA 619-303-4848 Fees ($) Add'I Fees ($) Total ($) Balance ($) 248 0 248 0 about:blank 1/1 7 1 -07-06p 1 1: P&Mdey Consulfing Engineers 350 9d1 Avenue, Suite L E0djd0, California 920255053 T0l11011 (760) 7456181 Fax( 760) 745O537 November 3, 2006 Robert Ledesma I - City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Ocean Mist Condos,- Oak Avenue, Carlsbad, CA Dear Mr. Ledesma: We have reviewed the submittal as prepared by Sexton Fire. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. Special attention should be paid to review comment #1, and the redline indications on the drawings as revised hydraulic calculations may be required. Sincerely, PA EY CONSULTING ENGINEERS i enneth W. agonei!ET Office Manager End (1) Working Drawings - 2 sets Hydraulic Calculations - 2 sets Review Comments - 1 set Note A copy of this letter has been transmitted via fax to Sexton Fire on November 3, 2006 File :'C:\REVIEWS\Rev2O6 I40.002.wpd From: Sexton Fire Protection Date: 10/23/06 11522 Wilder Way Lakeside, Ca 92040 (619) 303-4848 To: City of Carlsbad Fire Prevention District Re: Ocean Mist Condos 345 Oak Avenue Carlsbad, Ca This is a letter of response to the plan review letter received for the above project. All comments are in the same order of the plan review letter: Revised General Note "B" to indicate correct noting. See sheet I of 5. Revised General Note "H" to indicate the correct section reference for Testing & Acceptance of Underground Pipe. NFPA 13'02 Edition. See sheet I of 5. Added a Project Data note. See sheet 1 of 5. Indicated on Riser Detail the dielectric union between Sch. 10 steel and copper. See sheet 1 of 5. Revised calc area. See sheet 3 of 5. Pipe hanger details were added and shown on sheet I of 5. Pipe hanger tics were added to fire sprinkler piping. See sheets 3,4 &5 of 5. EQ braces were added at garage piping on sheet 3 of 5. EQ calc was added and shown on sheet I of 5. Added a Pipe Penetration Detail to sheet I of 5. Relocated head to be 2 inches away from heat zone. See sheet 5 of 5. New Garage calcs per comment #5. See revised 2/2 inch main pipe size on sheet 3 of 5. Revised 13R calcs to reflect same pipe, length as shown on garage calc for segments 17-18. Revised 13R calc to reflect correct pipe length of 10'-6" for segment 9. Revised plan to reflect correct pipe size of 1 1/2 inch as shown on 13R calcs. See sheets 3 & 4 of 5. I From: Ken Wagoner To: Karyn Vaudreuil Date: 219/2006 Time: 11:10:20 AM Ott"'If Parsley Consulting Engineers 350 We8é 9& Avenue, Suite L E0020, Celii 92025-5053 Telephone (760) 745-6181 F,(760) 745-0537 Page 1 of 2 /LV February 9, 2006 Karyn Vaudreuil City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 '0 Subject: Fire Sprinkler Review for Ocean Mist Condominiums, ,Oak Avenue, Carlsbad, California Dear Ms. Vaudreuil: We have reviewed the submittal as prepared by Sexton Fire Protection. We do not recommend approval of said plans or hydraulic calculations subject to our comments which are enclosed. Further submittal should be required. Since this is not a recommendation for approval no drawings or calculations are being forwarded to you at this time. A second review fee of $75.00 will be required at the time of resubmittal. Sincerely, PARSLEY CONSULTI1NG ENGINEERS Ajt$f jtI W d st., Kenneth W. WagonerT Office Manager Li' End (1) Working Drawings - sets Hydraulic Calculations - sets Review Comments - I set Note: A copy of this letter has been transmitted via fax to Sexton Fire Protection on February 9, 2006 fz1e:\C.:\REVWS\Rev2O614O.00 1.wpd From: Ken Wagoner To: Karyn Vaudreuil Date: 2/9/2006 Time: 11:10:20 AM Page 2 of 2 Ocean Mist Condominiums Review Comments. Page 2 Review Comments Ocean Mist Condominiums, 345 Oak Avenue, Carlsbad, California Sheet 1 Comments General note B: NFPA-13A has not been published for many years. Revise this note to indicate NFPA-25, current edition. General note H: Change section reference in NFPA-13, current edition and 1999 edition have no such section. No information was found anywhere on drawing indicating whether or not automatic sprinklers were used by the architect/builder to offset a requirement for one hour construction. Verify with the architect/builder that this was not the case. if sprinklers were used to offset one hour construction then the system must be designed throughout the building in accordance with NFPA- 13, which would include, among other things, protection for the attic space. Tables in the UBC suggest that one hour construction would be required in a building of this size. Sheet 2 Comments Verify that dielectric between ductile iron and copper is in place. Sheet 3 Comments NFPA- 13, Section 11.2.3.1.8 requires that the remote area for a space below an unsprinklered combustible concealed space be increased to 3,000 square feet as a minimum. The exception to this requirement noted in 11.2.3.1.8(4)(b) is not allowed according to the annex reference, A. 11.2.3.1. 8(4)(b) when the framing is composite wood joist as it is in this building on the garage level. The remote area must therefore be increased to 3,000 square feet. There were no hangers shown, or details for copper hangers. No earthquake braces were found, nor were any earthquake brace calculations. No information found on penetration details for any rated walls. Sheet 5 Comments Verify that the head near the fireplace in the end unit is outside of the heat zone Calculations Pipe segments 13-14-15 in the garage calculation show 2" pipe, while the drawings show 2/2" Segments 17-18 in the garage calculations show different lengths for the same segments in the residential system calculations. NFPA- 13R calculations show segment 9 with an elevation change of approximately 10-4", however the pipe length is indicated as being only 6" long. This is not possible. Pipe segment # 11 in the NFPA-13R calculation shows 11/2" pipe while the drawing shows 11/4" Ocean Mist Condos Review Comments. Page 2 Review Comments Ocean Mist Condos, 345 Oak Avenue, Carlsbad, CA The wall between unit garages and the common garage should be field verified to be rated at least 1-hour. If this wall is not a 1-hour wall the calculations must be revised to show a remote area minimum width of at least 1.2 x 11,800, per NFPA- 13. The only way that the currently shown remote area is in compliance is if the wall shown is rated at 1-hour or more. Verify that there is dielectric separation between the 4" ductile iron pipe into the building and the 2¼" copper riser. The modification to the hydraulic calculations required by our original comment #12 was not made in the resubmitted calculations, even though the response from the designer indicated that it was done. The resulting 1.75 psi error does not place the system requirement for pressure above 90% of the available supply and no further modification is required. The following comments are for your information and will appear on every residential sprinkler review. The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the residence. This will be checked at final acceptance. Pressure required at base of riser will be verified to be available at time of final acceptance. Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures. Fixtures will be verified at final acceptance. Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at final acceptance inspection. Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat diffusers, etc.) This will be checked at final acceptance inspection. Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type with an appropriate temperature rating, commercial heads are acceptable in these areas. All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic. Consolidated ñreprotection, Inc. G57 Cantara Lane . Vita, CA 92081 NFPA (71GO) 908-7753 • fax: 295-7530 MEMBER 05-06 CA Ucen5e # C- I G-4 I 834 bcaputo©cox.net December 20, 2005 Carlsbad Fire Department, Fire Prevention Division 1635 Faraday Avenue Carlsbad, California 92008 RE: Flow Test Results - Ocean Mist, 335 Oak Ave., Carlsbad, CA On December 20, 2005 at 10:45 am, a flow test was to determine the available water supply for the design of a fire sprinkler system at the above referenced address. The test was conducted with representatives of the Carlsbad Municipal Water District and the Carlsbad Fire Department. Based upon maps provided by the Carlsbad Municipal Water District, the water main running east/west in Oak Ave between Lincoln and the Railroad track easement is a 12" diameter, circulating main located south of the centerline of the street. A hydrant located at the corner of Oak and Lincoln was used as the gauge hydrant with a hydrant located on the corner of Oak and Washington used to flow water from a 2-1/2" outlet. The results of this test were as follows: Static Pressure: 85 psi Residual Pressure: 78 psi Pitot Pressure: 80 psi Flow: 1350 gpm (1500 gpmx .9) As you know, this flow test represents an approximation of the available water supply at this location at the time this test was conducted. In accordance with Carlsbad Fire Department policy and NFPA 13 recommendations, these results should be reduced by a minimum 10% safety margin when applied to a fire sprinkler system hydraulic design. Please contact me if we can provide any additional information. Best regards, Bob Caputo President cc: Brent Sexton, Sexton Fire Protection fire * Life Safety • Conultinrj. Plannincj AnaIy515 • Inspections Carlsbad Municipal Water District Potable Water Discharge Event Report Date: lo 12,C C- V2)o Location: 3L,/5 O4 1 e /L/F Reason for Discharge Event: TE5 l- Type of Event: Initial Dewatering Water Mains Estimated Discharge Flow: /Oo &OXt Note: Includes flow testing and flushing Dewatering Reservoirs Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharge water. Start Time / 4" End Time 7.c'-c 'FoJ Pre-Dechlorination Residual: /1 Z Post-Dechlorination Residual: 0 (less than 0.1 mg/L) pH within limits of 6.0 and 9.0 Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediment or silted areas are cleared. Water Sampling Performed by: C It,. Comments: yjqr, -. 8 Ref 78 Submitted by: o r Reviewd by: (Name & Date TOTAL SPRINKLER FLOW TOTAL HOSE STREAM TOTAL WATER REQUIRED BASE OF RISER NODE: 32 FLOW 296.6 Gpm 250.0 Gpm 546.6 Gpm 296.6 Gpm PRESSURE 43.6 Psi ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. - LICENSE : C16 690423 DESIGNER SEXTON FIRE PROTECTION DATE : 10-26-2006 FILE : OMC2 JOB NAME : OCEAN MIST CONDOS LOCATION : 345 OAK DR., CARLSBAD, CA 92008 DESIGN DATA. DENSITY AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED ORD. HAZ. GRP. 1 0.120 Gpm/SqFt 130 SqFt 1800 SqFt 17 FLOW DATA. AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DISTRICT PHONE HYDRONICS: FIRE SPRINKLER HYDRAULICS 2.5- SUBMITTAL. Page 1 Ef4GINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS SOURCE STATIC : 76.0 Psi RESIDUAL : 70.0 Psi FLOW : 1350 Gpm NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR ------------------------------------------------------------------------------- Psi Gpm 1 8.0 5.60 7.7 15.6 2 8.0 5.60 8.2 16.0 3 8.0 5.60 9.9 17.6 4 8.0 11.0 5 7.5 11.8 6 8.0 5.60 7.8 15.7 7 8.0 5.60 8.3 16.1 8 8.0 5.60 9.9 17.7 9 8.0 11.0 10 7.5 11.8 11 8.0 5.60 8.0 15.9 12 8.0 5.60 8.5 16.3 13 8.0 5.60 10.2 17.9 14 8.0 11.4 15 7.5 12.2 16 8.0 5.60 8.5 16.4 17 8.0 5.60 9.0 16.8 18 8.0 5.60 10.8 18.4 19 8.0 12.0 20 7.5 12.9 21 8.0 5.60 9.4 17.1 22 8.0 5.60 9.9 17.6 23 8.0 5.60 11.9 19.3 24 8.0 13.2 25 7.5 14.1 26 8.0 5.60 13.8 20.8 27 8.0 5.60 14.5 21.4 28 8.0 15.4 29 7.5 16.0 30 7.5 35.2 31 2.5 42.1 32 0.5 43.6 33 0.0 43.9 34 3.0 43.4 35 5.0 42.8 36 5.0 45.9 37 3.0 47.0 38 5.0 SOURCE 47.1 546.6 HYDRONICS: FIRE SPRINKLER HYDRAULICS 2.5- SUBMITTAL. Page 2 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS SPRINKLERS FLOWING : 17 AREA PER SPRINKLER : 130 Sq Ft REQUIRED DENSITY : 0.12 Gpm/Sq Ft COMPUTED DENSITY : 0.12 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 296.6 Gpm INSIDE HOSE STREAM : 0 Gpm OUTSIDE HOSE STREAM : 250 Gpm at Source TOTAL WATER REQUIRED : 546.6 Gpm TOTAL SPRINKLER PRESS : 44.1 Psi VALVE FIXED LOSS : 3.0 Psi Copyright (1995) SUPPLY PRESS AVAILABLE : 74.9 Psi by DEMAND PRESS REQUIRED : 47.1 Psi Hydronics Engineering PRESSURE CUSHION : 27.8 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 19.5 F/S (510) 487-9160 HYDRONICS: FIRE SPRINKLER: HYDRAULICS 2.5- SUBMITTAL. Page 3 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) - 1 q= 15.6 K= 5.60 L= 8.5 Pt 7.7 Pt 7.7 1 Q= 15.6 F= F= 0.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.7 D= 1.055 TL= 8.5 0.0528 Pf 0.4 Pn 7.5 2 Pt 8.2 2 q= 16.0 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 8.2 Pt 8.2 2 Q= 31.6 F= F= 0.0 C= 150 Pe 0.0 Pv -0.9 Vel= 11.6 D= 1.055 TL= 8.5 0.1955 Pf 1.7 Pn 7.3 • 3 Pt 9.9 3 q= 17.6 K= 5.60 ------------------------------------------------------------------------- L= 3.5 Pt 9.9 Pt 9.9 3 Q= 49.2 F=T F= 3.0 C= 150. Pe 0.0 Pv -1.0 Vel= 12.1 D= 1.291 TL= 6.5 0.1658 Pf 1.1 Pn 8.9 4 Pt 11.0 4 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 11.0 Pt 11.0 4 Q= 49.2 F=T F= 3.0 C= 150 Pe 0.2 Pv -1.0 • Vel= 12.1 D= 1.291 TL= 3.5 0.1658 Pf 0.6 Pn 10.0 5 ------------------------------------------------------------------------- Pt 11.8 6 q= 15.6 K= 5.60 L= 8.5 Pt 7.8 Pt 7.8 5 Q= 15.7 F= F= 0.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.7 D= 1.055 TL= 8.5 0.0532 Pf 0.5 Pn 7.6 7 Pt 8.3 7 q= 16.1 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 8.3 Pt 8.3 6 • Q= 31.7 F= F= 0.0 C= 150 Pe 0.0 Pv -0.9 Vel= 11.7 D= 1.055 TL= 8.5 0.1969 Pf 1.7 Pn 7.4 8 Pt 9.9 8 q= 17.7 K= 5.60 ------------------------------------------------------------------------- L= 3.5 Pt 9.9 Pt 9.9 7 Q= 49.4 F=T F= 3.0 C= 150 Pe 0.0 Pv -1.0 Vel= 12.1 D= 1.291 TL= 6.5 0.1670 Pf 1.1 Pn 9.0 9 Pt 11.0 9 q= 0.0 K= 0.00 L= 0.5 Pt 11.0 Pt 11.0 8 Q= 49.4 F=T F= 3.0 C= 150 Pe 0.2 Pv -1.0 Vel= 12.1 D= 1.291 TL= 3.5 0.1670 Pf 0.6 Pn 10.1 10 Pt 11.8 11 q= 15.9 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 8.0 Pt 8.0 9 Q= 15.9 F= F= 0.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.8 D= 1.055 TL= 8.5 0.0546 Pf 0.5 Pn 7.8 12 Pt 8.5 HYDRONICS: FIRE SPRINKLER HYDRAULICS 2.5- SUBMITTAL. Page 4 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 12 q= 16.3 ------------------------------------------------------------------------------ K= 5.60 L= 8.5 Pt 8.5 Pt 8.5 10 Q= 32.2 F= F= 0.0 C= 150 Pe 0.0 Pv -0.9 Vel= 11.8 D= 1.055 TL= 8.5 0.2022 Pt 1.7 Pn 7.6 13 Pt 10.2 13 q= 17.9 K= 5.60 ------------------------------------------------------------------------- L= 3.5 Pt 10.2 Pt 10.2 11 Q= 50.1 F=T F= 3.0 C= 150 Pe 0.0 Pv -1.0 Vel= 12.3 D= 1.291 TL= 6.5 0.1715 Pt 1.1 Pn 9.2 14 Pt 11.4 14 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L=. 0.5 Pt 11.4 Pt 11.4 12 Q= 50.1 F=T F= 3.0 C= 150 Pe 0.2 Pv -1.0 Vel= 12.3 D= 1.291 TL= 3.5 0.1715 Pt 0.6 Pn 10.3 15 Pt 12.2 16 q= 16.4 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 8.5 Pt 8.5 13 Q= 16.4 F= F= 0.0 C= 150 Pe 0.0 Pv -0.2 Vel= 6.0 D= 1.055 TL= 8.5 0.0577 Pt 0.5 Pn 8.3 17 Pt 9.0 17 q= 16.8 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 9.0 Pt 9.0 14 Q= 33.2 F= F= 0.0 C= 150 Pe 0.0 Pv -1.0 Vel= 12.2 D= 1.055 TL= 8.5 0.2135 Pt 1.8 Pn 8.0 18 Pt 10.8 18 q= 18.4 K= 5.60 ------------------------------------------------------------------------- L= 3.5 Pt 10.8 Pt 10.8 15 Q= 51.6 F=T F= 3.0 C= 150 Pe 0.0 Pv -1.1 Vel= 12.6 D= 1.291 TL= 6.5 0.1810 Pt 1.2 Pn 9.8 19 Pt 12.0 19 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 12.0 Pt 12.0 16 Q= 51.6 F=T F= 3.0 C= 150 Pe 0.2 Pv -1.1 Vel= 12.6 D= 1.291 TL= 3.5 0.1810 Pt 0.6 Pn 11.0 20 Pt 12.9 21 q= 17.1 K= 5.60 L= 8.5 - Pt 9.4 Pt 9.4 17 Q= 17.1 F= F= 0.0 C= 150 Pe 0.0 Pv -0.3 Vel= 6.3 D= 1.055 TL= 8.5 0.0630 Pt 0.5 Pn 9.1 22 Pt 9.9 22 q= 17.6 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 9.9 Pt 9.9 18 Q= 34.8 F= F= 0.0 C= 150 Pe 0.0 Pv -1.1 Vel= 12.8 D= 1.055 TL= 8.5 0.2331 Pt 2.0 Pn 8.8 23 Pt 11.9 HYDRONICS: FIRE SPRINKLER HYDRAULICS 2.5- SUBMITTAL. Page 5 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 23 q= 19.3 ------------------------------------------------------------------------------ K= 5.60 L= 3.5 Pt 11.9 Pt 11.9 19 Q= 54.1 F=T F= 3.0 C= 150 Pe 0.0 Pv -1.2 Vel= 13.3 D= 1.291 TL= 6.5 0.1975 Pf 1.3 Pn 10.7 24 Pt 13.2 24 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 13.2 Pt 13.2 20 Q= 54.1 F=T F= 3.0 C= 150 Pe 0.2 Pv -1.2 Vel= 13.3 D= 1.291 TL= 3.5 0.1975 Pf 0.7 Pn 12.0 25 Pt 14.1 26 q= 20.8 K= 5.60 ------------------------------------------------------------------------- L= 8.5 Pt 13.8 Pt 13.8 21 Q= 20.8 F= F= 0.0 C= 150 Pe 0.0 Pv -0.4 Vel= 7.6 D= 1.055 TL= 8.5 0.0900 Pf 0.8 Pn 13.4 27 Pt 14.5 27 q= 21.4 K= 5.60 ------------------------------------------------------------------------- L= 3.5 Pt 14.5 Pt 14.5 22 Q= 42.1 F=T F= 3.0 C= 150 Pe 0.0 Pv -0.7 Vel= 10.3 D= 1.291 TL= 6.5 0.1245 Pf 0.8 Pn 13.8 28 Pt 15.4 28 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 15.4 Pt 15.4 23 Q= 42.1 F=T F= 3.0 C= 150 Pe 0.2 Pv -0.7 Vel= 10.3 D= 1.291 TL= 3.5 0.1245 Pf 0.4 Pn 14.6 29 Pt 16.0 5 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 13.5 Pt 11.8 Pt 11.8 24 Q= 49.2 F= F= 0.0 C= 150 Pe 0.0 Pv -0.1 Vel= 3.2 D= 2.495 TL= 13.5 0.0067 Pf 0.1 Pn 11.7 10 Pt 11.8 10 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 13.5 Pt 11.8 Pt 11.8 25 Q= 98.6 F= F= 0.0 C= 150 Pe 0.0 Pv -0.3 Vel= 6.5 D= 2.495 TL= 13.5 0.0242 Pf 0.3 Pn 11.6 15 Pt 12.2 15 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 13.5 Pt 12.2 Pt 12.2 26 Q= 148.8 F= F= 0.0 C= 150 Pe 0.0 Pv -0.6 Vel= 9.8 D= 2.495 TL= 13.5 0.0518 Pf 0.7 Pn 11.5 20 Pt 12.9 20 q= 0.0 K= 0.00 ------------------------------------------------------------------------ L= 13.5 Pt 12.9 Pt 12.9 27 Q= 200.4 F= F= 0.0 C= 150 Pe 0.0 Pv -1.2 Vel= 13.1 D= 2.495 TL= 13.5 0.0899 Pf 1.2 Pn 11.7 - 25 Pt 14.1 HYDRONICS: FIRE SPRINKLER HYDRAULICS 2.5- SUBMITTAL. Page 6 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-26-2006 File: OMC2 JOB : OCEAN MIST CONDOS PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 25 q= 0.0 K= 0.00 L= 13.5 Pt 14.1 Pt 14.1 28 Q= 254.5 F= F= 0.0 C= 150 Pe 0.0 Pv -1.9 Vel= 16.7 D= 2.495 TL= 13.5 0.1400 Pf 1.9 Pn 12.2 29 Pt 16.0 29 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 82.0 Pt 16.0 Pt 16.0 29 Q= 296.6 F=5E F= 20.0 C= 150 Pe 0.0 Pv -2.5 Vel= 19.5 D= 2.495 TL= 102.0 0.1859 Pf 19.0 Pn 13.5 30 Pt 35.2 30 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 6.5 Pt 35.2 Pt 35.2 30 Q= 296.6 F=BC F= 19.0 C= 150 Pe 2.2 Pv -2.5 Vel= 19.5 D= 2.495 TL= 25.5 0.1859 Pf 4.7 Pn 32.6 31 Pt 42.1 31 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 3.0 Pt 42.1 Pt 42.1 31 Q= 296.6 F= F= 0.0 C= 150 Pe 0.9 Pv -2.5 Vel= 19.5 D= 2.495 TL= 3.0 0.1859 Pf 0.6 Pn 39.6 32 Pt 43.6 32 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 4.0 Pt 43.6 Pt 43.6 32 Q= 296.6 F=E F= 7.0 C= 140 Pe 0.2 Pv -0.3 Vel= 6.6 D= 4.280 TL= 11.0 0.0152 Pf 0.2 Pn 43.3 33 Pt 43.9 33 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 38.0 Pt 43.9 Pt 43.9 33 Q= 296.6 F=E F= 15.0 C= 150 Pe -1.3 Pv -0.3 Vel= 6.8 D= 4.230 TL= 53.0 0.0142 Pf 0.8 Pn 43.6 34 Pt 43.4 34 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 4.0 Pt 43.4 Pt 43.4 34 Q= 296.6 F=T F= 16.0 C= 140 Pe -0.9 Pv -0.3 Vel= 6.6 D= 4.280 TL= 20.0 0.0152 Pf 0.3 Pn 43.1 35 Pt 42.8 35 Q= 296.6 - Pt 42.8 BFP FIXED PRESSURE LOSS Valve 3.0 36 Pt 45.9 36 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 4.0 Pt 45.9 Pt 45.9 36 Q= 296.6 F=2E F= 14.0 C= 140 Pe 0.9 Pv -0.3 Vel= 6.6 D= 4.280 TL= 18.0 0.0152 Pf 0.3 Pn 45.6 37 Pt 47.0 37 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 34.0 Pt 47.0 Pt 47.0 37 - Q= 296.6 F=TG F= 33.0 C= 150 Pe -0.9 Pv -0.3 - Vel= 6.8 D= 4.230 TL= 67.0 0.0142 Pf 1.0 Pn 46.7 38 Pt 47.1 ------------------------------------------------------------------------- - 38 Q= 546.6 SOURCE >>> Pt 47.1 ------------------------------------------------------------------------- E=>90-E1b T=>TeeBch L=>Lt-E1b C=>ChkVlv B=>BfyVlv G=>GatVlv A=>AlmChk HYDRONICS : FIRE SPRINKLER HYDRAULIC GRAPH PSI 80 + X Static x 70 - X Resid 60 + * Spr Sys 10 + * Elev Loss 0 ++--+---+----+ ------+ --------+ --------+ ---------+ ----------+ ------------+ 0 400 600 800 1000 1200 1400 1600 1800 2000 1.85 FLOW-(GPM) JOB OCEAN MIST CONDOS X - Water Supply Curve Static : 76.0 Psi - Residual : 70.0 Psi Flow : 1350.0 Gpm * - Water Demand Curve Avail Press 74.9 Psi @ 546.6 Gpm Req'd Press 47.1 Psi @ 546.6 Gpm Press Cush'n 27.8 Psi HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 1 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNIT5-44 JOB : OCEAN MIST CONDOS - 2ND FLOOR 4 SSP 16X16 14 GPM STATIC : 76.0 Psi RESIDUAL : 70.0 Psi FLOW : 1350 Gpm SPRINKLER MANUF : RELIABLE MODEL : F1RES49 MIN SPR FLOW : 14.0 Gpm MIN SPR PRES : 8.2 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 31.5 4.90 ------------------------------------------------------------------------------- 8.2 14.0 2 31.5 4.90 9.4 15.0 3 31.5 10.0 4 31.5 4.90 9.8 15.3 5 31.5 10.3 6 31.5 10.9 7 31.5 4.90 13.2 17.8 8 31.5 13.9 9 31.5 16.7 10 21.0 22.4 11 21.0 25.8 12 10.0 32.4 13 10.0 48.8 31 2.5 57.2 32 0.5 58.1 33 0.0 58.3 34 3.0 57.1 35 5.0 56.2 36 5.0 59.2 37 3.0 60.1 38 5.0 SOURCE 59.3 62.1 SPRINKLERS FLOWING : 4 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 1024 Sq Ft REQUIRED DENSITY : 0.05 Gpm/Sq Ft COMPUTED DENSITY : 0.05 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 62.1 Gpm TOTAL DOMESTIC FLOW : 0.0 Gpm TOTAL WATER REQUIRED : 62.1 Gpm TOTAL SPRINKLER PRESS : 56.3 Psi WATER METER LOSS : 0.0 Psi at Source VALVE FIXED LOSS : 3.0 Psi Copyright (1995) SUPPLY PRESS AVAILABLE : 76.0 Psi by DEMAND PRESS REQUIRED : 59.3 Psi Hydronics Engineering PRESSURE CUSHION : 16.7 Psi 34119 Fremont Bi, Suite 609 - Fremont, Ca., 94555 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 2 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNIT5-44 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 14.0 ------------------------------------------------------------------------------ K= 4.90 L= 28.0 Pt 8.2 Pt 8.2 1 Q= 14.0 F=R3L F= 22.0 C= 150 Pe 0.0 Pv -0.2 Vel= 4.7 D= 1.101 TL= 50.0 0.0352 Pf 1.8 Pn 8.0 3 Pt 10.0 2 q= 15.0 K= 4.90 L= 2.5 Pt 9.4 Pt 9.4 2 Q= 15.0 F=BL F= 12.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.1 D= 1.101 TL= 14.5 0.0399 Pf 0.6 Pn 9.2 3 Pt 10.0 3 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 2.0 Pt 10.0 Pt 10.0 3 Q= 29.0 F=B F= 5.0 C= 150 Pe 0.0 Pv -0.6 Vel= 9.8 D= 1.101 TL= 7.0 0.1354 Pf 0.9 Pn 9.3 6 Pt 10.9 4 q= 15.3 K= 4.90 ------------------------------------------------------------------------- L= 2.0 Pt 9.8 Pt 9.8 4 Q= 15.3 F=BL F= 12.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.2 D= 1.101 TL= 14.0 0.0415 Pf 0.6 Pn 9.6 5 Pt 10.3 5 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 8.5 Pt 10.3 Pt 10.3 5 Q= 15.3 F=B F= 5.0 C= 150 Pe 0.0 Pv -0.2 Vel= 5.2 D= 1.101 TL= 13.5 0.0415 Pf 0.6 Pn 10.2 6 Pt 10.9 6 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 8.0 Pt 10.9 Pt 10.9 6 Q= 44.3 F=2R F= 2.0 C= 150 Pe 0.0 Pv -1.5 Vel= 14.9 D= 1.101 TL= 10.0 0.2965 Pf 3.0 Pn 9.4 8 Pt 13.9 7 q= 17.8 K= 4.90 ------------------------------------------------------------------------- L= 3.5 Pt 13.2 Pt 13.2 7 Q= 17.8 F=2B F= 10.0 C= 150 Pe 0.0 Pv -0.2 Vel= 6.0 D= 1.101 TL= 13.5 0.0546 Pf 0.7 Pn 12.9 8 Pt 13.9 8 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 8.0 Pt 13.9 Pt 13.9 8 Q= 62.1 F=B2R F= 8.0 C= 150 Pe 0.0 Pv -1.1 Vel= 13.0 D= 1.394 TL= 16.0 0.1753 Pf 2.8 Pn 12.7 9 Pt 16.7 9 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 16.7 Pt 16.7 9 Q= 62.1 F=B F= 6.0 C= 150 Pe 4.5 Pv -1.1 Vel= 13.0 D= 1.394 TL= 6.5 0.1753 Pf 1.1 Pn 15.6 - 10 Pt 22.4 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 3 ENGINEERS : ROY LEE (805) 933-2444. '-ADDRES : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: 1JN1T5-44 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 10 q= 0.0 ------------------------------------------------------------------------------ K= 0.00 L= 9.0 Pt 22.4 Pt 22.4 10 Q= 62.1 F=L2R F= 10.0 C= 150 Pe 0.0 Pv -1.1 Vel= 13.0 D= 1.394 TL= 19.0 0.1753 Pt 3.3 Pn 21.3 11 Pt 25.8 11 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 11.0 Pt 25.8 Pt 25.8 11 Q= 62.1 F=L F= 9.0 C= 150 Pe 4.8 Pv -0.7 Vel= 9.9 D= 1.598 TL= 20.0 0.0901 Pt 1.8 Pn 25.1 12 Pt 32.4 12 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 129.5 Pt 32.4 Pt 32.4 12 Q= 62.1 F=4L4R F= 16.0 C= 150 Pe 0.0 Pv -0.8 Vel= 10.9 D= 1.527 TL= 145.5 0.1125 Pf 16.4 Pn 31.6 13 Pt 48.8 13 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 10.0 Pt 48.8 Pt 48.8 13 Q= 62.1 F=BLG2SR F= 35.0 C= 150 Pe 3.2 Pv -0.8 Vel= 10.9 D= 1.527 TL= 45.0 0.1125 Pt 5.1 Pn 48.0 31 ------------------------------------------------------------------------- Pt 57.2 31 q= 0.0 K= 0.00 L= 2.0 Pt 57.2 Pt 57.2 14 Q= 62.1 F= F= 0.0 C= 120 Pe 0.9 Pv -0.1 Vel= 3.7 D= 2.635 TL= 2.0 0.0119 Pt 0.0 Pn 57.1 32 Pt 58.1 32 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 5.0 Pt 58.1 Pt 58.1 15 Q= 62.1 F=L F= 13.0 C= 140 Pe 0.2 Pv -0.0 Vel= 1.4 D= 4.280 TL= 18.0 0.0008 Pt 0.0 Pn 58.1 33 Pt 58.3 33 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 36.0 Pt 58.3 Pt 58.3 16 Q= 62.1 F=L F= 15.0 C= 150 Pe -1.3 Pv -0.0 Vel= 1.4 D= 4.230 TL= 51.0 0.0008 Pt 0.0 Pn 58.3 34 Pt 57.1 34 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 4.0 Pt 57.1 Pt 57.1 17 Q= 62.1 F=B F= 27.0 C= 140 Pe -0.9 Pv -0.0 Vel= 1.4 D= 4.280 TL= 31.0 0.0008 Pf 0.0 Pn 57.0 35 Pt 56.2 35 Q= 62.1 ------------------------------------------------------------------------- Pt 56.2 BFP FIXED PRESSURE LOSS Valve 3.0 36 Pt 59.2 36 q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 4.0 Pt 59.2 Pt 59.2 19- Q= 62.1 F=2L F= 26.0 C= 140 Pe 0.9 Pv -0.0 Vel= 1.4 D= 4.280 TL= 30.0 0.0008 Pf 0.0 Pn 59.2 37 Pt 60.1 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 4 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNIT5-44 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 37 q= 0.0 ------------------------------------------------------------------------------ K= 0.00 L= 34.0 Pt 60.1 Pt 60.1 20 Q= 62.1 F=BG F= 33.0 C= 150 Pe -0.9 Pv -0.0 Vel= 1.4 D= 4.230 TL= 67.0 0.0008 Pf 0.1 Pn 60.1 38 Pt 59.3 ------------------------------------------------------------------------- Meter = 0.0 38 Q= 62.1 <<< ------------------------------------------------------------------------- ------------------------------------------------------------------------- SOURCE >>> Pt 59.3 E=>45-E1b L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv -PSI -100 + 90 + 80 + X Static 70 + N. X Resid HYDRONICS : FIRE SPRINKLER HYDRAULIC GRAPH 60 + Spr Sys 50 + 20 + ' Elev Loss 10+ - 0 ++--+---+----+ ------+ -------+ --------+ ---------+ ----------+ ------------+ 0 400 600 800 1000 1200 1400 1600 1800 2000 1.85 FLOW-(GPM) JOB : OCEAN MIST CONDOS - 2ND FLOOR 4 SSP 16X16 14 GPM X - Water Supply Curve * - Water Demand Curve Static : 76.0 Psi Avail Press 76.0 Psi @ 62.1 Gpm Residual : 70.0 Psi Req'd Press 59.3 Psi @ 62.1 Gpm Flow : 1350.0 Gpm Press Cush'n 16.7 Psi HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 1 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNITS-11 JOB : OCEAN MIST CONDOS - 2ND FLOOR 1 SSP 16X16 14 GPM STATIC : 76.0 Psi RESIDUAL : 70.0 Psi FLOW : 1350 GPM SPRINKLER MANUF : RELIABLE MODEL : F1RE549 MIN SPR FLOW : 14.0 GPM MIN SPR PRES : 8.2 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR ------------------------------------------------------------------------------- Psi GPM 1 31.5 4.90 8.2 14.0 2 31.5 9.9 3 31.5 9.9 4 31.5 10.2 5 31.5 10.2 6 31.5 10.2 7 31.5 10.5 8 31.5 10.5 9 31.5 10.7 10 21.0 15.3 11 21.0 15.5 12 10.0 20.4 13 10.0 21.5 31 2.5 25.0 32 0.5 25.9 33 0.0 26.1 34 3.0 24.8 35 5.0 24.0 36 5.0 27.0 37 3.0 27.8 38 5.0 SOURCE 27.0 14.0 SPRINKLERS FLOWING : 1 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 256 Sq Ft REQUIRED DENSITY : 0.05 Gpm/Sq Ft COMPUTED DENSITY : 0.05 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 14.0 GPM TOTAL DOMESTIC FLOW : 0.0 GPM TOTAL WATER REQUIRED : 14.0 GPM TOTAL SPRINKLER PRESS : 24.0 Psi WATER METER LOSS : 0.0 Psi at Source VALVE FIXED LOSS : 3.0 Psi Copyright (1995) SUPPLY PRESS AVAILABLE : 76.0 Psi by DEMAND PRESS REQUIRED : 27.0 Psi Hydronics Engineering PRESSURE CUSHION : 49.0 Psi 34119 Fremont Bi, Suite 609 - Fremont, Ca., 94555 MAXIMUM VELOCITY : 4.7 F/S HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 2 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNIT5-11 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 14.0 ------------------------------------------------------------------------------ K= 4.90 L= 28.0 Pt 8.2 Pt 8.2 1 Q= 14.0 F=R3L F= 22.0 C= 150 Pe 0.0 Pv -0.1 Vel= 4.7 D= 1.101 TL= 50.0 0.0351 Pf 1.8 Pn 8.0 3 Pt 9.9 2 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 2.5 Pt 9.9 Pt 9.9 2 Q= 0.0F=BL F= 12.0 C=150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 1.101 TL= 14.5 0.0000 Pf 0.0 Pn 9.9 3 Pt 9.9 3 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 2.0 Pt 9.9 Pt 9.9 3 Q= 14.0 F=B F= 5.0 C= 150 Pe 0.0 Pv -0.1 Vel= 4.7 D= 1.101 TL= 7.0 0.0351 Pf 0.2 Pn 9.8 6 Pt 10.2 4 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 2.0 Pt 10.2 Pt 10.2 4 Q= 0.0F=BL F= 12.0 C=150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 1.101 TL= 14.0 0.0000 Pf 0.0 Pn 10.2 5 Pt 10.2 5 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 8.5 Pt 10.2 Pt 10.2 5 Q= 0.0 F=B F= 5.0 C= 150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 1.101 TL= 13.5 0.0000 Pf 0.0 Pn 10.2 6 Pt 10.2 6 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 8.0 Pt 10.2 Pt 10.2 6 Q= 14.0 F=2R F= 2.0 C= 150 Pe 0.0 Pv -0.1 Vel= 4.7 D= 1.101 TL= 10.0 0.0351 Pf 0.4 Pn 10.0 8 Pt 10.5 7 q= 0.0 K= 0.00 -------------------------------------------------------------------------- L= 3.5 Pt 10.5 Pt 10.5 7 Q= 0.0 F=2B F= 10.0 C= 150 Pe 0.0 Pv 0.0 Vel= 0.0 D= 1.101 TL= 13.5 0.0000 Pf 0.0 Pn 10.5 8 Pt 10.5 8 q= 0.0 K= 0.00 ------------------------------------------------------------------------ L= 8.0 Pt 10.5 Pt 10.5 8 Q= 14.0 F=B2R F= 8.0 C= 150 Pe 0.0 Pv -0.1 Vel= 2.9 D= 1.394 TL= 16.0 0.0111 Pf 0.2 Pn 10.5 9 Pt 10.7 9 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 0.5 Pt 10.7 Pt 10.7 9 Q= 14.0 F=B F= 6.0 C= 150 Pe 4.5 Pv -0.1 Vel= 2.9 D= 1.394 TL= 6.5 0.0111 Pf 0.1 Pn 10.6 10 Pt 15.3 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 3 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: UNIT5-11 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. GPM FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 10 q= 0.0 ------------------------------------------------------------------------------ K= 0.00 L= 9.0 Pt 15.3 Pt 15.3 10 Q= 14.0 F=L2R F= 10.0 C= 150 Pe 0.0 Pv -0.1 Vel= 2.9 D= 1.394 TL= 19.0 0.0111 Pf 0.2 Pn 15.3 11 Pt 15.5 11 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 11.0 Pt 15.5 Pt 15.5 11 Q= 14.0 F=L F= 9.0 C= 150 Pe 4.8 Pv -0.0 Vel= 2.2 D= 1.598 TL= 20.0 0.0057 Pt 0.1 Pn 15.5 12 Pt 20.4 12 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 129.5 Pt 20.4 Pt 20.4 12 Q= 14.0 F=4L4R F= 16.0 C= 150 Pe 0.0 Pv -0.0 Vel= 2.5 D= 1.527 TL= 145.5 0.0071 Pf 1.0 Pn 20.4 13 Pt 21.5 13 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 10.0 Pt 21.5 Pt 21.5 13 Q= 14.0 F=BLG2SR F= 35.0 C= 150 Pe 3.2 Pv -0.0 Vel= 2.5 D= 1.527 TL= 45.0 0.0071 Pt 0.3 Pn 21.4 31 Pt 25.0 31 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 2.0 Pt 25.0 Pt 25.0 14 Q= 14.0 F= F= 0.0 C= 120 Pe 0.9 Pv -0.0 Vel= 0.8 D= 2.635 TL= 2.0 0.0008 Pt 0.0 Pn 25.0 32 Pt 25.9 32 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 5.0 Pt 25.9 Pt 25.9 15 Q= 14.0 F=L F= 13.0 C= 140 Pe 0.2 Pv -0.0 Vel= 0.3 D= 4.280 TL= 18.0 0.0001 Pt 0.0 Pn 25.9 33 Pt 26.1 33 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 36.0 Pt 26.1 Pt 26.1 16 Q= 14.0 F=L F= 15.0 C= 150 Pe -1.3 Pv -0.0 Vel= 0.3 D= 4.230 TL= 51.0 0.0000 Pt 0.0 Pn 26.1 34 Pt 24.8 34 q= 0.0 K= 0.00 ------------------------------------------------------------------------- L= 4.0 Pt 24.8 Pt 24.8 17 Q= 14.0 F=B F= 27.0 C= 140 Pe -0.9 Pv -0.0 Vel= 0.3 D= 4.280 TL= 31.0 0.0001 Pf 0.0 Pn 24.8 35 Pt 24.0 35 Q= 14.0 ------------------------------------------------------------------------- Pt 24.0 BFP FIXED PRESSURE LOSS Valve 3.0 36 Pt 27.0 36 q= 0.0 K= 0.00 - ------------------------------------------------------------------------- L= 4.0 Pt 27.0 Pt 27.0 19 Q= 14.0 F=2L F= 26.0 C= 140 Pe 0.9 Pv -0.0 - Vel= 0.3 D= 4.280 TL= 30.0 0.0001 Pt 0.0 Pn 27.0 - 37 Pt 27.8 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 2.5 - SUBMITTAL. Page 4 ENGINEERS : ROY LEE (805) 933-2444. ADDRESS : 812 Railroad Avenue, Santa Paula, CA 93060. Date: 10-27-2006 File: TJNIT5-11 JOB PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 37 q= 0.0 ------------------------------------------------------------------------------ K= 0.00 L= 34.0 Pt 27.8 Pt 27.8 20 Q= 14.0 F=BG F= 33.0 C= 150 Pe -0.9 Pv -0.0 Ve1= 0.3D= 4.230 TL= 67.0 0.0000 Pf 0.0 Pn 27.8 38 Pt 27.0 ------------------------------------------------------------------------- Meter = 0.0 38 Q= 14.0 <<< ------------------------------------------------------------------------- ------------------------------------------------------------------------- SOURCE >>> Pt 27.0 E=>45-E1b L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS : FIRE SPRINKLER HYDRAULIC GRAPH -PSI _100 + 90 + 80 + X Static 70 - 60 + 50 + 40 + X Resid 30 + * Spr Sys 20 + * Elev Loss 10 + 0 ++--+---+----+ ------+ -------+ --------+ ---------+ ----------+ ------------+ 0 400 600 800 1000 1200 1400 1600 1800 2000 FLOW-(GPM) JOB : OCEAN MIST CONDOS - 2ND FLOOR 1 SSP 16X16 14 GPM X - Water Supply Curve * - Water Demand Curve Static : 76.0 Psi Avail Press 76.0 Psi @ 14.0 Gpm Residual 70.0 Psi Req'd Press 27.0 Psi @ 14.0 Gpm Flow : 1350.0 Gpm Press Cush'n 49.0 Psi