Loading...
HomeMy WebLinkAbout2230 NOB HILL DR; ; AS090080; Permit7/19/22, 2:32 PM AS090080 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090080 Job Address: 2230. NOB HILL DR Permit Type: SPRINK Parcel No: 1671122700 Lot #: 0 Status: ISSUED Applied 7/16/2009 Approved: 7/16/2009 Reference No.: Issued: 7/16/2009 PC #: Inspector: Project Title: JOHNSON RESIDENCE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: JOHNSON FAMILY TRUST 08-20-08 2230 NOB HILL DR CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 Asoiooso WEST COAST FIRE PROTECTION 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR Johnson Guesthouse 2230 Nob Hill Carlsbad CA FILE NUMBER: DATE: JUL 14, 2009 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: N/A gpm/sq. ft. AREA OF APPLICATION: Bed Room W/ flat ceiling COVERAGE PER SPRINKLER: 16x16 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 18.0 gpm TOTAL WATER REQUIRED (including hose) : 23.0 gpm FLOW AND PRESSURE (@ BOR) : 18 gpm @ 29.1 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN AMATO AUTHORITY HAVING JURISDICTION: Carlsbad Fire Department SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/14/2009 C:\HASS78\JOHNSONRES.SDF JOB TITLE: JOHNSON RESIDENCE WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRCE 70.0 65.0 100.0 69.7 23.0 40.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 23.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 5.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 18.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 15.0 K= 4.20 18.4 18.0 TOR 8.0 - - - - 24.6 - - - BOR 0.5 - - - - 29.1 - - - Ui -2.0 - - - - 31.4 - - - Mi 8.0 - - - - 28.3 - - - M2 8.0 - - - - 39.3 - - - SRCE 8.0 SOURCE 40.5 18.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/14/2009 C:\HASS78\JOHNSONRES.SDF JOB TITLE: JOHNSON RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -18.0 1.101 PL 23.00 PF 3.2 1 15.0 4.2 18.4 18.0 6.1 150 FTG 35.0 PE 3.0 TOR 8.0 0.0 24.6 0.0 0.056 TL 58.00 PV Pipe: 2 -18.0 1.101 PL 11.58 PF 1.2 TOR 8.0 0.0 24.6 0.0 6.1 150 FTG 10.0 PE 3.2 BOR 0.5 0.0 29.1 0.0 0.056 TL 21.58 PV Pipe: 3 -18.0 1.030 PL 5.00 PF 1.2 BOR 0.5 0.0 29.1 0.0 6.9 150 FTG 10.0 PE 1.1 Ui -2.0 0.0 31.4 0.0 0.077 TL 15.00 PV Pipe: 4 -18.0 1.590 PL 130.00 PF 1.2 Ui -2.0 0.0 31.4 0.0 2.9 150 FTG 3.0 PE -4.3 Ml 8.0 0.0 28.3 0.0 0.009 TL 133.00 PV Pipe: 5 FIXED PRESSURE LOSS DEVICE M2 8.0 0.0 39.3 0.0 11.0 psi, 18.0 gpm Ml 8.0 0.0 28.3 0.0 Pipe: 6 -18.0 1.025 PL 15.00 PF 1.2 M2 8.0 0.0 39.3 0.0 7.0 150 FTG ---- PE 0.0 SRCE 8.0 SRCE 40.5 (N/A) 0.079 TL 15.00 PV NOTES (HASS) Calculations were performed by the HASS 7.9 computer program under license no. 27081246 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.013 gpm and a maximum imbalance at any node of 0.078 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 7.0 ft/sec at pipe 6. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/14/2009 C:\HASS78\JOHNSONRES.SDF JOB TITLE: JOHNSON RESIDENCE PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEii ChkVlv BfyVlv GatVlv AimChk DPVlv NPTee 1.025 1.79 4.47 1.79 4.47 5.36 0.89 8.93 8.93 4.47 1.030 1.83 4.57 1.83 4.57 5.49 0.91 9.15 9.15 4.57 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 1.590 3.76 7.53 1.88 8.47 5.65 0.94 9.41 9.41 7.53 C C C Alf 0 C 0 0 c) 0 0 C" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 7/14/2009 C:\HASS78\JOHNSONRES.SDF JOB TITLE: JOHNSON RESIDENCE -1 ('1 '-' r C C C 0 C C 0 0 0 0 0 0 C 0 0 0 0 0 I C N k.0 Li_I C) C'J —QU)d-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/14/2009 C:\HASS78\JOHNSONRES.SDF JOB TITLE: JOHNSON RESIDENCE WATER SUPPLY CURVE 72+ * 0 \ 66\ 1* <-65.0 psi @ 100 gpm Flow Test Point 60+ 54+ P 48+ R I E I S I S 42+ U X R I E 36+ ( I P I S I I 30+ ) I 24+ 18+ 12+ LEGEND I X = Required Water Supply 40.45 psi @ 23.0 gpm 6+ I 0 = Available Water Supply 69.67 psi @ 23.0 gpm 'V 0++-+---+----+-----+ ------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) A 60 ~Dc) go tqC102 /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 ,a rapid response HOME FIRE SPRINKLER SYSTEM Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.2 K-factor General Description The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible sol- der sprinklers designed for use in resi- dential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII (TY2596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut to help assure a perfect fit installation. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2596) has a 4.2 (60,5) K-factor that provides the re- quired residential flow rates at reduced IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in afire situation or cause it to operate prematurely. Page 1 of 4 pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (TY2596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (1Y2596) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. WARNINGS The Series LFII (TY2596) Residential Concealed Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. SprinklerNodel Identification Number SIN 1Y2596 JANUARY, 2006 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psill2 (60,5 LPM/bar112) Temperature Rating: 160°F/71°C Sprinkler with 135°F/57°C Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Cover Plate: Flat White, Bright White, Chrome, or Custom Physical Characteristics: Body ..............Brass Cap ..............Bronze Saddle .............Brass Sealing Assembly .......... Beryllium Nickel w/ Teflont Soldered Link Halves .....Nickel Lever .............Bronze Compression Screw ......Brass Deflector ...........Copper TFP44O F- Page 2 of 4 TFP44O Minimum Flow (i)) and Minimum Flow (b) and Minimum Flow ("I and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) Ft. (Max. 2 Inch Rise (Greater Than 2 Inch (Greater Than 4 Inch Ft. x Ft. (m) for 12 Inch Run) Rise Up To Rise Up To (m x m) Max. 4 Inch Rise for 12 Inch Run) Max. 8 Inch Rise for 12 Inch Run) 160'FI7I°C 160°F171°C 160°F171°C Sprinkler Sprinkler Sprinkler 12x12 12 13 GPM (49,2LPM) I8 GPM (68,1LPM) 1S GPM (68,1LPM) (3,7 x 3,7) (3,7) 9.6 psi (0,66 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 14x 14 14 14 GPM (53,0 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16x 16 16 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,9 x4,9) (4,9) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 18x 18 18 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) N/A (5,5 x 5,5) (5.5) 22.7 psi (1,57 bar) 22.7 psi (1.57 bar) 20 x 20 20 24 GPM (90,8 LPM) 26 GPM (98,4 LPM) N/A (6,1 x 6,1) (6,1) 327 psi (2,25 bar) 1 38.3 psi (2,64 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Guide Pin Housing ......Bronze Guide Pins ......Stainless Steel Support Cup ..........Steel Cover Plate ..........Copper Retainer ............Brass Cover Plate Ejection Spring ..... ...Stainless Steel tDuPont Registered Trademark Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series IFIl (TY2596) Residential Concealed Pendent Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers' as specified in NFPA 130 or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 130 and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). installation The Series LFll (TY2596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- .-J TFP44O BODY (1/2" NPT) - CAP SADDLE SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER SOLDER LINK ELEMENT I' 'I I II I II I DEFLECTOR (OPERATED I I POSITION) I I SPRINKLER!SIJPPORT CUP ASSEMBLY I I I I I I RETAINER H WITH THREAD H H - DIMPLES EJECTION SPRING COVER PLATEIRETAINER ASSEMBLY COVER PLATE FIGURE 1 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Page 3 of 4 mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W-Type 18 Wrench shown in Fig- ure 2, install and tighten the Sprink- ler/Support Cup Assembly into the fit- ting. The W-Type 18 Wrench will accept a 112 inch ratchet drive. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH 2-1/2" DIA. SPRINKLER- (63,5 ASSEMBLY 112" THREADED SPRINKLER (63,5 mm 1/2" (12,7 mm) FACE OF _/OPERAThD ___ NPT ADJUSTMENT FITTING ___ 7' SPRINKLER _____________ PLATE - (49,2 mm RETAINER 1/8 GAP ±6,4 mm) 1-15/16"±114" COVER 1/2" (12,7 mm) I COVER- SPRINKLER- I RETAINER SUPPORT CUP • MOUNTING 3/16 SURFACE IDISPOSABLE ASSEMBLY ASSEMBLY (4,8 mm) , V(254 mm) 3-3/16"DIA. DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS I PROTECTIVE CAP /ACTIVATED DEFLECTOR Page 4 of 4 TFP440 Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Arms during ceiling in- stallation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. NOTE As long as the protective Cap remains in place, the system is considered to be "Out Of Service". Step 5. After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be en- gaged sufficiently to contact the ceil- ing, the Sprinkler Fitting must be repo- sitioned. Care and Maintenance The Series LFII (TY2596) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- kiers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyers repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness for a This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted bylaw. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (1Y2596), K4.2, Residen- tial Concealed Pendent Sprinkler with- out Cover Plate Assembly, P/N 51-122-1-160. Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFII (1Y2596), K4.2, Residential Concealed Pen- dent Sprinkler, P/N (specify). Chrome ..................PIN 56-122-9-135 Off White.................PIN 56-122-0-135 Bright White ............... P/N 56-122-4-135 Flat White ................PIN 56-122-5-135 White (RALSO1O) ........... P/N 56-122-3-135 Custom ..................PIN 56-122-X-135 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to V4" (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. 4tE1UlIC -I AUTOMATIC SPRINKLERS FIRE PROTECTION PROUTS V27, K5.6 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- tern for standard commer- - cial applications. They are 707 available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- <> (fl () () rates state-of-the-art, heat responsive, frangible glass See vitc bulb design (standard or publication 1001 V2707 details. quick response) for prompt, V2708 precise operation. The die cast frame is more streamlined and attractive hex )J than traditional sand cast Pendent v27T frames. It is cast with a V2704 -shaped wrench boss to (j allow easy tightening from Upright F- TECHNICAL SPECIFICATIONS Models: V2703, V2704, V2707 V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: ½' (13 mm) K-Factor: 5.6 Imp. (8,1 SI.") Nominal Thread Size: ½' NPT (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mn. Operating Pressure: 7 psi (48kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 mm U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 U Recessed: V38, V38-3 U Socket: V27 Finishes: U Plain brass U Chrome plated U White painted** U Custom painted** 0 Lead** 155, 200, 286SR Only - Q Wax** U Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. For K-Factor when pressure is mea- sured in Bar, multiply SA. units by 10.0. Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-742-5842) Phone: 905-884-7444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8817 Fax: 905-884-9774 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@victaulic.com e-mail: viccanada@victaulic.com e-mail: viceuro@victaulic.be e-mail: eical@victaulic.com e-mail: vicap@victaulic.com 2544 Rev.O 8/03 5 Registered Trademark of Victaulic 0 Copyright 2003 Victaulic Printed in U.S.A. APPROVALSILISTINGS Nominal Approved Temperature Ratings °FI°C Orifice Size K-Factor Inches Imperial Deflector Model millimeters S.LA Response Type UL FM ULC NYCIMEAt CSFM § V2703 ½ 5.6 Standard Upright 135-360 135-360 135-360 135-360 135-360 13 8.1 57-182 57-182 57-182 57-182 57-182 V2707 ½ 5.6 Standard Pendent 135-360 135-360 135-360 135-360 135-360 13 8,1 57-182 57-182 57-182 57-182 57-182 ½5.6 Recessed Pendent 135-360 135-200 135-360 135 -360 135 -360 V2707 13 8,1 Standard Up to °R Adjustment 57-182 57-93 57-182 57-182 57-182 V2704 1h 5.6 Quick Upright 135-286 135-286 135-286 135-286 135-286 13 8,1 57- 141 57-141 57- 141 -----57-141 57 -141 V2708 1h 5.6 Quick Pendent 135-286 135-286 135-286 135-286 135-286 13 8,1 57-141 57-141 57-141 57-141 57-141 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8,1 Quick Up tow Adjustment 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135 -200 V2708 13 8,1 Quick Up to ~' Adjustment 1 57 -93 No 57 -93 57 -93 1 57 -93 t Listings and approval as of printrng. a All are approved open, except for areas designated N0. For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. MEA #62-99-E. § CSFM #7690-0531:112 t RATINGS All glass bulbs are rated for temperatures from -67°F (-5 5°C) up to those shown in adjacent table. Temperature - °FI°C Nominal Maximum Sprinkler Victaulic Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary c 55 168 100 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 93 150 65 Green High J 286 141 225 - 107 Blue Extra High t K 360 182 300 149 Purple - I M Open = No Bulb Standard response only. All are approved open, except for areas designated No. - 150/65 if wax coated. E1 ORDERING INFORMATION Please specify the following when ordering: 0 Sprinkler Model Number U K-Factor 0 Sprinkler Finish O Style 0 Thread Size 0 Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number A%W1TRNIJiG Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safely glasses and loot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300. 40.10 -2 17A6 (37 mm) (66 1W (41 mm) 2W (60 mm) DIMENSIONS (25 MM) 1 k Standard Pendent - V2707, V2708 Standard Upright- V2703, V2704 Recessed - V2707, V2708 (Drawing not to scale) 23W (60 mm) Max. Hole 2(51 mm) Mm. He (33 mm) (24 mm) Typical Ceiling TO (149nm) _____ 1,y . (24 mm) Finished Surface (43 mm) MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (Drawing not to scale) I I AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V270],V2]08Pendent / / / V2707, V2708 Recessed Pendent V2703, V2704 Upright 40.10-3 DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT 10' 3,0 m 8' 2,4m 6' 1,8 m 4, 1,2 m 2' 0,6 m 0 7 psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa 2' 4' 6' 8' 10' 12' 14' 0,6 m 1,2 m 1,8 m 2,4 m 3,0 m 3,7 m 4,3 m MODELS V2703, V2104 1(5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY -- -- m ' m -- \ - -- "S \ m \ m -- 2' 4' 6' 8' 10' 12' 14' 16' 0,6m 1,2rn 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. I— I WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance nlh current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4 10' 3,0 m 8 2,4 6' 1,8 4 1,2 2 0,6 0 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa