HomeMy WebLinkAbout3525 NORTH FORK AVE; ; AS110023; Permit7/19/22, 3:56 PM AS110023 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS110023
3525 NORTH FORK
Job Address:
AV
Permit Type: SPRINK
Parcel No: 1683726900
Lot #: 0
Status: ISSUED
Applied 3/1/2011
Approved: 3/1/2011
Reference No.: Issued: 3/1/2011
PC #: Inspector:
Project Title: ROCK ROSE SPRINKLER INSPECTION THREE FIRE
SPRINKLER INSPECTIONS @ $65/EA
Applicant: Owner:
BROOKFIELD ROBERTSON P A 16 L L C
12865 POINTE DEL MAR WAY #200
DEL MAR CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
195 -195 0 0
about:blank 1/1
As u ous r-Auo03
Parsley Consulting
350 West 9th Avenue, Suite 206
Escondido, California 920255053
Telephone (760) 745-6181 Fa(760) 745-0537
February 24, 2011
Mr. James Weigand
City of Carlsbad Fire Department
Office of Fire Protection Services
1635 Faraday Avenue
Carlsbad, California 92008
Subject: Plan Review for Rockrose At Robertson Ranch, Plans 1-3, Carlsbad, California
Dear Mr Weigand:
We have reviewed the submittal as prepared by Innovative Fire.
Based on our review it is our opinion that the submittal is in substantial conformance with the
applicable codes and standards in force at this time, including local adopted ordinances.
Further submittal should not be required.
Sincerely,
Xenneth
EYCONSULTJNG
W agone, T
Office Manager
End (1) Working Drawings - 2 sets
Hydraulic Calculations - 2 sets
Review Comments - 1 set
Note: A copy of this letter has been transmitted via fax to Innovative Fire on Febru Y 24, 2011
9577
CA ;t.-3 5I3 ii 1
it It 6/IO JO L/
3
I' ft
C4311 file:\C ni :\1)ocuents and Settings\Ken\Rev211128.001,wpd
031(7 611/
o1IO3f
Rockrose At Robertson Ranch Review Comments. Page 2
Review Comments
Rockrose At Robertson Ranch, Plans 1-3, Carlsbad, California
On plan 1 there was a minor dimension error, which has been redlined. No resubmittal required.
On plan 2 the second floor was mis-labeled, and this has been redlined. No resubmittal required.
Revised hydraulic calculations for plan 2 resulted in revisions to the hydraulic sign, and these
have been redlined. No resubmittal is required.
The following comments are for your information and will appear on every residential sprinkler review.
The alarm bell must be capable of being heard, above background noise, with doors closed, in all living areas of the
residence. This will be checked at final acceptance.
Pressure required at base of riser will be verified to be available at time of final acceptance.
Sprinkler heads are omitted from bathroom areas under 55 SF in area with noncombustible plumbing fixtures.
Fixtures will be verified at final acceptance.
Sprinkler head blockage or pattern disruption caused by beams or other obstructions will be verified to not exist at
final acceptance inspection.
Sprinkler heads should be located the proper distance from heat sources (stoves, kitchen ranges, fireplaces, heat
diffusers, etc.) This will be checked at final acceptance inspection.
Sprinkler heads located in an unconditioned space (garage, water heater closet, etc.) should be fast response type
with an appropriate temperature rating, commercial heads are acceptable in these areas.
All exposed piping shall be black steel or copper. Concealed piping can be CPVC plastic.
1
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 42/14/2011 C:\HASS74\c4519.SDF
JOBrITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR As~toov;r-j
*'WATER SUPPLY DATA Aioo
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 63.0 57.6 500.0 63.0 31.0 58.7
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 31.0 GPM
TOTALHOSE STREAM ALLOWANCE AT SOURCE 00 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26:0 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 SOURCE 58.7 31.0
2 47.6
2A -10 43.6
HOSE STREAM 42.5 5.0
R 20 40.4 -
P - - : = -
- -
20 - - -
U.2 -1.0 - - -- 35.6
U.3 1.0 --- 33.6
U.4 1.0 --- 32.9
3 3.5
- - -
31.0 - - -
4 6.5 - --- 28.0
5 9.5
- - -
22.2 - - -
6 9.5 - 19.2 - - -
7 - - 9.5 - 1 16.1 - - -
8 -
-
20.0 - - -- 9.6
BA 19.5 -
- -
- - -
9 20.0 - = -- 7.3
9A 195 K= 4.90 7.1 13
10A 19.5 K= 4.90 7.0 13:0
s have heer reviewed for apparent contpliaiice
rretit applicable codes and staitdards in knee
diction The owner or contraciol ma utilize
Fwoh CIT'( OF CAR[_ BIAD in supportof an application w a building
h the express uiidersiaiidiilg lint this
FIRE DEPARTMENT relieves the owner or contractor oi ihcii
APPR OVED priilessioflal engineer or architect tor sole responsibility
for lull coinpb ance with said codes and standards,
lincluding the building code or for any responsihilty boi
Subject to ficd tnpctoi and quired Ideficiencies errors omissions or negligence in these
tests, nota'iois 't cr •
review
,
or not noted in his review
correspondi 'cc rc :' 'i.L wth te /4//t Reviewer;
regulac s. ii 'v. i9
of these plans shinn' I. . tj-cMMENl) APPROVAL
A or ap tt e vioitoi of 0 RECOMMfNt) APlRO VAt.. AS NOTED
P, y ''
4 ce75
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB.TITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 31.0 0.995 FL 35.00 PF 11.1
1 -1.0 SRCE 58.7 (N/A) 12.8 150 FTG TG FE 0.0
2 -1.0 0.0 47.6 0.0 0.251 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 47.6 0.0 4.0 psi, 31.0 gprn
2A -1.0 0.0 43.6 0.0
Pipe: 3 31.0 1.025 PL 2.00 PF 1.1
2A -1.0 0.0 43.6 0.0 12.1 150 FTG E FE 0.0
U.1 -1.0 H.S. 42.5 5.0 0.217 TL 5.00 PV
Pipe: 4 26.0 1.025 PL 2.00 PF 0.8
U.1 -1.0 H.S. 42.5 5.0 10.1 150 FTG E FE -1.3
R 2.0 0.0 40.4 0.0 0.157 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 40.4 0.0 5.0 psi, 26.0 gpm
P 2.0 0.0 35.4 0.0
Pipe: 6 26.0 1.590 FL 45.00 PF 1.2
F 2.0 0.0 35.4 0.0 4.2 150 FTG E4L FE 1.3
U.2 -1.0 0.0 35.6 0.0 0.018 TL 63.00 PV
Pipe: 7 26.0 1.505 PL 10.00 PF 1.2
U.2 -1.0 0.0 35.6 0.0 4.7 150 FTG 3E2LC FE -0.9
U.3 1.0 0.0 33.6 0.0 0.024 TL 48.00 PV
Pipe: 8 26.0 1.025 PL 1.00 PF 0.6
U.3 1.0 0.0 33.6 0.0 10.1 150 FTG E FE 0.0
U.4 1.0 0.0 32.9 0.0 0.157 TL 4.00 PV
Pipe: 9 26.0 1.025 FL 2.50 PF 0.9
U.4 1.0 0.0 32.9 0.0 10.1 150 FTG E FE -1.1
3 3.5 0.0 31.0 0.0 0.157 TL 5.50 PV
Pipe: 10 26.0 1.049 FL 3.00 PF 1.7
3 3.5 0.0 31.0 0.0 9.7 120 FTG C FE -1.3
4 6.5 0.0 28.0 0.0 0.212 TL 8.00 PV
Pipe: 11 26.0 1.101 PL 16.50 PF 4.5
4 6.5 0.0 28.0 0.0 8.8 150 FTG 3E3R FE -1.3
5 9.5 0.0 22.2 0.0 0.111 TL 40.50 PV
Pipe: 12 14.5 1.101 PL 50.00 PF 3.0
5 9.5 0.0 22.2 0.0 4.9 150 FTG E3TBR FE 0.0
6 9.5 0.0 19.2 0.0 0.037 TL 80.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 2/14/2011 C:\FIASS74\C4519.SDF
JOBTITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR
41
'PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 26.0 1.101 FL 16.50 PP 3.2
6 9.5 0.0 19.2 0.0 6.8 150 FTG 2T2R FE 0.0
7 9.5 0.0 16.1 0.0 0.111 TL 28.50 PV
Pipe: 14 26.0 1.101 FL 10.00 PF 1.9
7 9.5 0.0 16.1 0.0 8.8 150 FTG T2R FE -4.5
8 20.0 0.0 9.6 0.0 0.111 TL 17.00 PV
Pipe: 15 0.0 1.101 FL 4.00 PF 0.0
8 20.0 0.0 9.6 0.0 0.0 150 FTG ETR FE 0.2
8A 19.5 0.0 9.9 0.0 0.000 TL 17.00 PV
Pipe: 16 26.0 1.101 FL 15.00 PF 2.3
8 20.0 0.0 9.6 0.0 8.8 150 FTG TR FE 0.0
9 20.0 0.0 7.3 0.0 0.111 TL 21.00 PV
Pipe: 17 13.0 1.101 FL 2.50 PF 0.5
9 20.0 0.0 7.3 0.0 4.4 150 FTG ETR FE 0.2
9A 19.5 4.9 7.1 13.0 0.031 TL 15.50 PV
Pipe: 18 13.0 1.101 PL 7.00 PP 0.5
9 20.0 0.0 7.3 0.0 4.4 150 FTG E2R PE 0.2
10A 19.5 4.9 7.0 13.0 0.031 TL 16.00 PV
Pipe: 19 -11.5 1.101 FL 101.50 PP 3.0
6 9.5 0.0 19.2 0.0 3.9 150 FTG ETSR FE 0.0
5 9.5 0.0 22.2 0.0 0.025 TL 121.50 PV
NOTES (HASS):
Calculations were performed by the HASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.005 gpm and a maximum
imbalance at any node of 0.088 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 12.8 ft/sec at pipe 1.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB.TITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR
(4) PIPE FITTINGS TABLE
Pipe Table Name: FSS.PIP
PAGE: A MATERIAL: SCH40 HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: 11 MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Ell Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
on
'Ii
80.0
70.0
60.
G
A
U
G 50.
E
LEGEND
Available pressure
62.97 psi @ 31.0 gpm
Required pressure
58.67 psi @ 31.0 gpm
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB TITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR
'WATER SUPPLY ANALYSIS
Static: 63.00 psi Resid: 57.60 psi Flow: 500.0 gpm
A. Source Supply Curve
P 40. 'Ii B. System Demand Curve
R
E
30. on
S
U
R
E 20.
p 10. an
S
1
I
20(300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 1/14//2011 C:\ntt,4\C45i9.SuF
JOB TITLE: ROCKROSE PLAN 1X TWO HEAD CALC-2nd FLOOR
WATER SUPPLY CURVE
72+
66+
60+ \\\\\
x \\\\
I * <-57.6 psi @ 500 gpm
I Flow Test Point
54+
P 48+
R I
E I
S I
S 42+
U
R I
E I
36+
( I
P
S
I 30+
24+
18+
12+ LEGEND
I I,
X = Required Water Supply
58.67 psi @ 31.0 gpm
6+
I 0 = Available Water Supply
62.97 psi @ 31.0 gpm
0++-+---+----+-----+------+--------+--------+---------+-----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOBTITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
'WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 63.0 57.6 500.0 63.0 25.0 55.4
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 25.0 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 -1.0 SOURCE 55.4 25.0
2 -1.0 - - - - 48.0 - - -
2A -1.0 - - - - 44.0
U.1 -1.0 HOSE STREAM 43.3 5.0
R 2.0 - - - - 41.5
P 2.0 - - - - 36.5 - - -
U.2 -1.0 - - - - 37.1
U.3 1.0 - - - - 35.5
U.4 1.0 - - - - 35.1
3 3.5 - - - - 33.5 - - -
4 6.5 - - - - 31.1 - - -
5 9.5 - - - - 27.1
6 9.5 - - - - 25.2 - - -
7 9.5 - - - - 23.3 - - -
8 20.0 - - - - 17.6
8A 19.5 K= 4.90 16.7 20.0
9 20.0 - - - - 17.6 - - -
9A 19.5 - - - - 17.8
10A 19.5 - - - - 17.8
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB'TITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 25.0 0.995 PL 35.00 PF 7.4
1 -1.0 SRCE 55.4 (N/A) 10.3 150 FTG TG PE 0.0
2 -1.0 0.0 48.0 0.0 0.169 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 48.0 0.0 4.0 psi, 25.0 gprn
2A -1.0 0.0 44.0 0.0
Pipe: 3 25.0 1.025 PL 2.00 PF 0.7
2A -1.0 0.0 44.0 0.0 9.7 150 FTG E FE 0.0
U.1 -1.0 H.S. 43.3 5.0 0.146 TL 5.00 PV
Pipe: 4 20.0 1.025 PL 2.00 PF 0.5
U.1 -1.0 H.S. 43.3 5.0 7.8 150 FTG E FE -1.3
R 2.0 0.0 41.5 0.0 0.096 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 41.5 0.0 5.0 psi, 20.0 gpra
P 2.0 0.0 36.5 0.0
Pipe: 6 20.0 1.590 FL 45.00 PF 0.7
P 2.0 0.0 36.5 0.0 3.2 150 FTG E4L FE 1.3
U.2 -1.0 0.0 37.1 0.0 0.011 TL 63.00 PV
Pipe: 7 20.0 1.505 FL 10.00 PF 0.7
U.2 -1.0 0.0 37.1 0.0 3.6 150 FTG 3E2LC FE -0.9
U.3 1.0 0.0 35.5 0.0 0.015 TL 48.00 PV
Pipe: 8 20.0 1.025 PL 1.00 FE' 0.4
U.3 1.0 0.0 35.5 0.0 7.8 150 FTG E FE 0.0
U.4 1.0 0.0 35.1 0.0 0.096 TL 4.00 PV
Pipe: 9 20.0 1.025 FL 2.50 FE' 0.5
U.4 1.0 0.0 35.1 0.0 7.8 150 FTG E FE -1.1
3 3.5 0.0 33.5 0.0 0.096 TL 5.50 PV
Pipe: 10 20.0 1.049 PL 3.00 PF 1.0
3 3.5 0.0 33.5 0.0 7.4 120 FTG C FE -1.3
4 6.5 0.0 31.1 0.0 0.130 TL 8.00 PV
Pipe: 11 20.0 1.101 FL 16.50 PF 2.8
4 6.5 0.0 31.1 0.0 6.7 150 FTG 3E3R FE -1.3
5 9.5 0.0 27.1 0.0 0.068 TL 40.50 PV
Pipe: 12 11.1 1.101 FL 50.00 PF 1.8
5 9.5 0.0 27.1 0.0 3.7 150 FTG E3TBR FE 0.0
6 9.5 0.0 25.2 0.0 0.023 TL 80.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB'TITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
'PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13
r
20.0 1.101 FL 16.50 PF 1.9
6 9.5 0.0 25.2 0.0 6.7 10 FTG 2T2R Fr. 0.0
7 9.5 0.0 23.3 0.0 0.068 TL 28.50 PV
Pipe: 14 20.0 1.101 FL 10.00 PF 1.2
7 9.5 0.0 23.3 0.0 6.7 150 FTG T2R FE -4.5
8 20.0 0.0 17.6 0.0 0.068 TL 17.00 PV
Pipe: 15 20.0 1.101 PL 4.00 PF 1.2
8 20.0 0.0 17.6 0.0 6.7 150 FTG ETR FE 0.2
8A 19.5 4.9 16.7 20.0 0.068 TL 17.00 PV
Pipe: 16 0.0 1.101 FL 15.00 PF 0.0
8 20.0 0.0 17.6 0.0 0.0 150 FTG TR FE 0.0
9 20.0 0.0 17.6 0.0 0.000 TL 21.00 PV
Pipe: 17 0.0 1.101 PL 2.50 PF 0.0
9 20.0 0.0 17.6 0.0 0.0 150 FTG ETR PE 0.2
9A 19.5 0.0 17.8 0.0 0.000 TL 15.50 PV
Pipe: 18 0.0 1.101 PL 7.00 PF 0.0
9 20.0 0.0 17.6 0.0 0.0 150 FTG E2R FE 0.2
10A 19.5 0.0 17.8 0.0 0.000 TL 16.00 PV
Pipe: 19 -8.9 1.101 PL 101.50 PF 1.8
6 9.5 0.0 25.2 0.0 3.0 150 FTG ET6R FE 0.0
5 9.5 0.0 27.1 0.0 0.015 TL 121.50 PV
NOTES (HASS)
Calculations were performed by the HASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.005 gpm and a maximum
imbalance at any node of 0.089 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 10.3 ft/sec at pipe 1.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 / DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB 'TITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
(4) PIPE FITTINGS TABLE
Pipe Table Name: FSS.PIP
PAGE: A MATERIAL: SCH40 HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Eli Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 2/14/2011 C:\HASS74\C4519.SDF
JOB 'TITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
'WATER SUPPLY ANALYSIS
Static: 63.00 Psi Resid: 57.60 psi Flow: 500.0 gpm
80.0
70.0
]
60. IN I
G
A 4
U
G 50. II
E
P 40. DL
R
E
S 30. III
S
U
R
E 20. Ii
p 10.
S
1
0.
LEGEND
Available pressure
62.96 psi @ 25.0 gpm
Required pressure
55.40 psi @ 25.0 gpm
Source Supply Curve
System Demand Curve
-1.4.71 1 I 1 1 1 I I I I
20(300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
' DATE: 2/14j'2011 C:\HASS74\C4519.0'DF
JOB 'TITLE: ROCKROSE PLAN 1X ONE HEAD CALC-2nd FLOOR
'WATER SUPPLY CURVE
72+
66+
0\\\\
I \\\\
60+
* <-57.6 psi @ 500 gpm
X Flow Test Point
54+
P 48+
R I
E
S I
S 42+
U I
R I
E I
36+
P I
S
I 30+
) I
24+
18+
12+ LEGEND
I X = Required Water Supply
I 55.40 Psi @ 25.0 gpm
6+
I 0 = Available Water Supply
62.98 psi @ 25.0 gpm
0++-+---+----+-----+------+--------+--------+---------+-----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 2/24/2011 C:\NASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQD
NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) )GPM( (PSI)
1 63.0 57.6 500.0 63.0 31.2 50.3
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 31.2 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER NOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
)FT) (PSI) )GPM)
1 -1.0 SOURCE 50.3 31.2
2 -1.0 - - - - 39.2
2A -1.0 - - - - 35.2
U.1 -1.0 HOSE STREAM 34.1 5.0
R 2.0 - - - - 32.0 - - -
P 2.0 - - - - 27.0
U.2 -1.0 - - - - 27.1 - - -
U.3 1.0 - - - - 25.1 - - -
U.4 1.0 - - - - 24.4 - - -
3 3.5 - - - - 22.5
4 6.5 - - - - 19.5 - - -
5 9.5 - - - - 14.7 - - -
6 20.0 - - - - 9.2 - - -
7 20.0 - - - - 7.7
8 20.0 - - - - 7.5 - - -
8A 19.5 K= 4.90 7.3 13.2
9 20.0 - - - - 7.6 - - -
9A 19.5 - - - - 7.8
10 20.0 - - - - 7.6 - - -
11 20.0 - - - - 7.5 - - -
hA 19.5 14= 4.90 7.0 13.0
12 9.5 - - - - 12.5
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/24/2011 C:\HASS7I\C4519-92.SDF
JOB TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HM(C) )FT( SUM.
NODES )FT( (K) (PSI) (GPM( FL/FT (PSI)
Pipe: 1 31.2 0.995 PL 35.00 PF 11.2
1 -1.0 SRCE 50.3 (N/A) 12.9 150 FTG TG PE 0.0
2 -1.0 0.0 39.2 0.0 0.254 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 39.2 0.0 4.0 psi, 31.2 gpm
2A -1.0 0.0 35.2 0.0
Pipe: 3 31.2 1.025 PL 2.00 PF 1.1 2A -1.0 0.0 35.2 0.0 12.1 150 FTG E PE 0.0
U.1 -1.0 N.S. 34.1 5.0 0.219 TL 5.00 PV
Pipe: 4 26.2 1.025 PL 2.00 PF 0.8
U.1 -1.0 H.S. 34.1 5.0 10.2 150 FTG E PE -1.3 R 2.0 0.0 32.0 0.0 0.159 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 32.0 0.0 5.0 psi, 26.2 gpm
P 2.0 0.0 27.0 0.0
Pipe: 6 26.2 1.590 PL 45.00 PF 1.2
P 2.0 0.0 27.0 0.0 4.2 150 FTG E4L PE 1.3
11.2 -1.0 0.0 27.1 0.0 0.019 TL 63.00 PV
Pipe: 7 26.2 1.505 PL 10.00 PF 1.2
U.2 -1.0 0.0 27.1 0.0 4.7 150 FTG 3E2LC PE -0.9
U.3 1.0 0.0 25.1 0.0 0.024 TL 48.00 PV
Pipe: 8 26.2 i.025 PL 1.00 PF 0.6
11.3 1.0 0.0 25.1 0.0 10.2 150 FTG S PE 0.0
U.4 1.0 0.0 24.4 0.0 0.159 TL 4.00 PV
Pipe: 9 26.2 1.025 PL 2.50 PF 0.9
U.4 1.0 0.0 24.4 0.0 10.2 150 FTG E PE -1.1
3 3.5 0.0 22.5 0.0 0.159 TL 5.50 PV
Pipe: 10 26.2 1.049 PL 3.00 PF 1.7
3 3.5 0.0 22.5 0.0 9.7 120 FTG C PE -1.3
4 6.5 0.0 19.5 0.0 0.214 TL 8.00 PV
Pipe: 11 26.2 1.101 PL 14.50 PF 3.4
4 6.5 0.0 19.5 0.0 8.8 150 FTG 2E2R PE -1.3
5 9.5 0.0 14.7 0.0 0.112 TL 30.50 PV
Pipe: 12 14.7 1.101 PL 10.50 PF 0.9
5 9.5 0.0 14.7 0.0 4.9 150 FTG ET2R PE -4.5
6 20.0 0.0 9.2 0.0 0.038 TL 24.50 PV
Pipe: 13 14.7 1.101 PL 27.00 PF 1.5 6 20.0 0.0 9.2 0.0 4.9 150 FTG 2T2R PE 0.0 7 20.0 0.0 7.7 0.0 0.038 TL 39.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
PIPE TAG Q(GPM) DIA(IN( LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW)C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 14 9.8 1.101 PL 9.50 SF 0.3
7 20.0 0.0 7.7 0.0 3.3 150 FTG T PE 0.0
8 20.0 0.0 7.5 0.0 0.018 TL 14.50 PV
Pipe: 15 13.2 1.101 PL 1.10 PF 0.4
8 20.0 0.0 7.5 0.0 4.4 150 FTG ETR PE 0.2
8A 19.5 4.9 7.3 13.2 0.032 TL 14.00 PV
Pipe: 16 -3.4 1.101 PL 32.50 PF 0.1
8 20.0 0.0 7.5 0.0 1.1 150 FTG 2E2R SE 0.0
9 20.0 0.0 7.6 0.0 0.003 TL 48.50 PV
Pipe: 17 0.0 1.101 PL 0.50 SF 0.0
9 20.0 0.0 7.6 0.0 0.0 150 FTG TR PE 0.2
9A 19.5 0.0 7.8 0.0 0.000 TL 6.50 PV
Pipe: 18 -3.4 1.101 PL 7.50 SF 0.0
9 20.0 0.0 7.6 0.0 1.1 150 FTG R SE 0.0
10 20.0 0.0 7.6 0.0 0.003 TL 8.50 PV
Pipe: 19 8.1 1.101 PL 5.00 SF 0.1
10 20.0 0.0 7.6 0.0 2.7 150 FTG T SE 0.0
11 20.0 0.0 7.5 0.0 0.013 TL 10.00 SV
Pipe: 20 13.0 1.101 PL 8.00 SF 0.7
11 20.0 0.0 7.5 0.0 4.4 150 FTG ET2R SE 0.2
hA 19.5 4.9 7.0 13.0 0.031 IL 22.00 PV
Pipe: 21 -4.9 1.101 PL 31.00 SF 0.2
11 20.0 0.0 7.5 0.0 1.6 150 FTG 2E5R SE 0.0
7 20.0 0.0 7.7 0.0 0.005 TL 50.00 PV
Pipe: 22 -11.5 1.101 PL 10.00 SF 0.3
10 20.0 0.0 7.6 0.0 3.9 150 FTG 2R SE 4.5
12 9.5 0.0 12.5 0.0 0.024 IL 12.00 PV
Pipe: 23 -11.5 1.101 PL 57.50 SF 2.3
12 9.5 0.0 12.5 0.0 3.9 150 FTG 2E4TR SE 0.0
5 9.5 0.0 14.7 0.0 0.024 TL 92.50 PV
NOTES (HASS)
Calculations were performed by the HASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.001 gpm and a maximum
imbalance at any node of 0.010 gpm.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 2/24/2011 C:\HASS74\C4519-52.SDF
JOB TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
Total pressure at each node is used in balancing the system.
Maximum water velocity is 12.9 ft/sec at pipe 1.
PIPE FITTINGS TABLE
Pipe Table Name: P55.515
SAGE: A MATERIAL: SCH40 HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A 0
Eli Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Eli Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B 0 A D
Eli Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40SVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B 0 A D
Eli Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
PAGE: K MATERIAL: CPPR-K HNC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B 0 A 0
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JON TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
WATER SUPPLY ANALYSIS
Static: 63.00 psi. Resid: 57.60 psi Flow: 500.0 gpm
80.0
70.0
60.0
0
A
U
G 50207-
E
P 40.0 -
R
E
30.0 - S
U
R
E 20.0
p 10.0
5
1
0.0B-
-14 .7
LEGEND
Available pressure
62.97 psi 8 31.2 gpm
Required pressure
50.33 psi 8 31.2 gpm
Source Supply Curve
System Demand Curve
200300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 TWO HEAD CALC-2nd FLOOR
WATER SUPPLY CURVE
72+
66+
I \\\\
60+ \\\\\
I \\\\
I * <-57.6 psi 8 500 gpm
I Flow Test Point
54 +
x
P 48+
R I
E I
S I
5 42+
U
R I
E
36+
P I
S I
I 30+
24+
18+
----------------
12+ LEGEND
I X = Required Water Supply
I 50.33 psi @ 31.2 gpm
6+
I 0 = Available Water Supply
62.97 psi 9 31.2 gpm
0++-+---+----+-----+------+ --------+--------+---------+ -----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAL CALC-2nd FLOOR
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. 9 PRESS. 8 DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 63.0 57.6 500.0 63.0 25.0 51.0
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 25.0 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM(
1 -1.0 SOURCE 51.0 25.0
2 -1.0 - - - - 43.6 - - -
2A -1.0 - - - - 39.6
U.1 -1.0 HOSE STREAM 38.9 5.0
R 2.0 - - - - 37.1 - - -
P 2.0 - - - - 32.1 - - -
U.2 -1.0 - - - - 32.7 - - -
U.3 1.0 - - - - 31.1 - - -
U.4 1.0 - - - - 30.7 - - -
3 3.5 - - - - 29.1
4 6.5 - - - - 26.7 - - -
5 9.5 - - - - 23.4
6 20.0 - - - - 18.3
7 20.0 - - - - 17.4 - - -
8 20.0 - - - - 17.3 - - -
8A 19.5 - - - - 17.5 - - -
9 20.0 - - - - 16.9 - - -
9A 19.5 K= 4.90 16.7 20.0
10 20.0 - - - - 17.2 - - -
11 20.0 - - - - 17.2 - - -
hA 19.5 - - - - 17.4 - - -
12 9.5 - - - - 21.9
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/24/2011 C:\HASS7I\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAL CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA)IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL)FPS) HW)C) )FT) SUM.
NODES )FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 25.0 0.995 PL 35.00 PF 7.4
1 -1.0 SRCE 51.0 (N/A) 10.3 150 FTG TO PE 0.0
2 -1.0 0.0 43.6 0.0 0.169 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 43.6 0.0 4.0 psi, 25.0 gpm
2A -1.0 0.0 39.6 0.0
Pipe: 3 25.0 1.025 PL 2.00 PF 0.7
2A -1.0 0.0 39.6 0.0 9.7 150 FTG E PE 0.0
U.1 -1.0 H.S. 38.9 5.0 0.146 TL 5.00 PV
Pipe: 4 20.0 1.025 PL 2.00 PF 0.5
U.1 -1.0 H.S. 38.9 5.0 7.8 150 FTG E PE -1.3
R 2.0 0.0 37.1 0.0 0.096 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 37.1 0.0 5.0 psi, 20.0 gpm
P 2.0 0.0 32.1 0.0
Pipe: 6 20.0 1.590 PL 45.00 PF 0.7
P 2.0 0.0 32.1 0.0 3.2 150 FTG E41, PE 1.3
U.2 -1.0 0.0 32.7 0.0 0.011 TL 63.00 PV
Pipe: 7 20.0 1.505 PL 10.00 PF 0.7
U.2 -1.0 0.0 32.7 0.0 3.6 150 FTG 3E2LC PE -0.9
U.3 1.0 0.0 31.1 0.0 0.015 TL 48.00 PV
Pipe: 8 20.0 1.025 PL 1.00 PF 0.4
U.3 1.0 0.0 31.1 0.0 7.8 150 FTG E PE 0.0
U.4 1.0 0.0 30.7 0.0 0.096 TL 4.00 PV
Pipe: 9 20.0 1.025 PL 2.50 PF 0.5
U.4 1.0 0.0 30.7 0.0 7.8 150 FTG E PE -1.1
3 3.5 0.0 29.1 0.0 0.096 TL 5.50 PV
Pipe: 10 20.0 1.049 PL 3.00 PF 1.0
3 3.5 0.0 29.1 0.0 7.4 120 FTG C FE -1.3
4 6.5 0.0 26.7 0.0 0.130 TL 8.00 PV
Pipe: 11 20.0 1.101 PL 14.50 PF 2.1
4 6.5 0.0 26.7 0.0 6.7 150 FTG 2E2R PE -1.3
5 9.5 0.0 23.4 0.0 0.068 TL 30.50 PV
Pipe: 12 10.9 1.101 PL 10.50 PF 0.5
5 9.5 0.0 23.4 0.0 3.7 150 FTG ET2R PE -4.5
6 20.0 0.0 18.3 0.0 0.022 TL 24.50 PV
Pipe: 13 10.9 1.101 PL 27.00 PF 0.9
6 20.0 0.0 18.3 0.0 3.7 150 FTG 2T2R PE 0.0
7 20.0 0.0 17.4 0.0 0.022 TL 39.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAD CALC-2nd FLOOR
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW)C) )FT) SUM.
NODES )FT) (K) (PSI) )GPM) FL/FT (PSI)
Pipe: 14 6.5 1.101 PL 9.50 PF 0.1
7 20.0 0.0 17.4 0.0 2.2 150 FTG T PE 0.0
8 20.0 0.0 17.3 0.0 0.008 TL 14.50 PV
Pipe: 15 0.0 1.101 PL 1.00 PF 0.0
8 20.0 0.0 17.3 0.0 0.0 150 FTG ETR PE 0.2
8A 19.5 0.0 17.5 0.0 0.000 TL 14.00 PV
Pipe: 16 6.5 1.101 PL 32.50 PF 0.4
8 20.0 0.0 17.3 0.0 2.2 150 FTG 2E2R PE 0.0
9 20.0 0.0 16.9 0.0 0.008 TL 48.50 PV
Pipe: 17 20.0 1.101 PL 0.50 PF 0.4
9 20.0 0.0 16.9 0.0 6.7 150 FTG TR PE 0.2
9A 19.5 4.9 16.7 20.0 0.068 TL 6.50 PV
Pipe: 18 -13.5 1.101 PL 7.50 PF 0.3
9 20.0 0.0 16.9 0.0 4.6 150 FTG R PR 0.0
10 20.0 0.0 17.2 0.0 0.033 TL 8.50 PV
Pipe: 19 -4.4 1.101 PL 5.00 PF 0.0
10 20.0 0.0 17.2 0.0 1.5 150 FTC T PR 0.0
11 20.0 0.0 17.2 0.0 0.004 TL 10.00 PV
Pipe: 20 0.0 1.101 PL 8.00 PF 0.0
11 20.0 0.0 17.2 0.0 0.0 150 FTG ET2R PR 0.2
hA 19.5 0.0 17.4 0.0 0.000 TL 22.00 PV
Pipe: 21 -4.4 1.101 PL 31.00 PF 0.2
11 20.0 0.0 17.2 0.0 1.5 150 FTC 2E5R PE 0.0
7 20.0 0.0 17.4 0.0 0.004 TL 50.00 PV
Pipe: 22 -9.1 1.101 PL 10.00 PF 0.2
10 20.0 0.0 17.2 0.0 3.1 150 FTG 2R PR 4.5
12 9.5 0.0 21.9 0.0 0.016 TL 12.00 PV
Pipe: 23 -9.1 1.101 PL 57.50 PF 1.5
12 9.5 0.0 21.9 0.0 3.1 150 FTG 2E4TR PE 0.0
5 9.5 0.0 23.4 0.0 0.016 TL 92.50 PV
NOTES (HASS)
Calculations were performed by the NASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.009 gpm and a maximum
imbalance at any node of 0.177 gpm.
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAD CALC-2nd FLOOR
Total pressure at each node is used in balancing the system.
Maximum water velocity is 10.3 ft/sec at pipe 1.
PIPE FITTINGS TABLE
Pipe Table Name: FSS.PIP
PAGE: A MATERIAL: SCHIO HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B 0 A D
Eli Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: H MATERIAL: CPVC HVJC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T N K C L B L
Eli Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L NMC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HMC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) K T L C B G A D
Eli Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
PAGE: K MATERIAL: CPPR-}< HMC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
70.0
60.0
G
A
U
502)
E
P 40.0
R
E
30.0
S
U
R
8 20.0
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: 2/24/2011 C:\}-{ASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAD CALC-2nd FLOOR
WATER SUPPLY ANALYSIS
Static: 63.00 psi Resid: 57.60 psi Flow: 500.0 gpm
80.0
LEGEND
Available pressure
62.98 psi @ 25.0 gpm
Required pressure
51.02 psi 8 25.0 gpm
Source Supply Curve
System Demand Curve
-14.71 1 I I I I 1 1 I I
200300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 2/24/2011 C:\HASS74\C4519-P2.SDF
JOB TITLE: ROCKROSE PLAN 2 ONE HEAD CALC-2nd FLOOR
WATER SUPPLY CURVE
72+
66+
I \\\\
60+ \\\\\
I \\\\
I * <-57.6 psi 8 500 gpm
I Flow Test Point
54+
x
P 48+
H I
E I
S
S 42+
U I
H I
8 I
36+
P I
S I
I 30+
24+
18+
-------------
12+ LEGEND
I X = Required Water Supply
I 51.02 psi 8 25.0 gpm
6+
I 0 = Available Water Supply
I 62.98 psi 9 25.0 gpm
0++-+---+----+-----+------+--------+ --------+---------+ -----------+
200 300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
4 DATE: '2/14/2011 C:\HASS74\C4519-P3.SDF
JOA TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 63.0 57.6 500.0 63.0 31.7 52.1
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 31.7 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.7 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 -1.0 SOURCE 52.1 31.7
2 -1.0 - - - - 40.6
2A -1.0 - - - - 36.6 - - -
U.1 -1.0 HOSE STREAM 35.5 5.0
R 2.0 - - - - 33.4
P 2.0 - - - - 28.4
U.2 -1.0 - - - - 28.4
U.3 1.0 - - - - 26.4
U.4 1.0 - - - - 25.7
3 3.5 - - - - 23.7
4 6.5 - - - - 20.6 - - -
5 9.5 - - - - 15.4
6 20.0 - - - - 9.5 - - -
7 20.0 - - - - 8.5 - - -
8 20.0 - - - - 7.8 - - -
8A 19.5 K= 4.90 7.0 13.0
9 20.0 - - - - 7.8 - - -
9A 19.5 K= 4.90 7.8 13.7
10 20.0 - - - - 8.2
10A 19.5 - - - - 8.4
11 20.0 - - - - 8.3
12 9.5 - - - - 13.3 - - -
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/14/2011 C:\HASS74\C4519-P3.SDF
JOB TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 31.7 0.995 PL 35.00 PF 11.5
1 -1.0 SRCE 52.1 (N/A) 13.1 150 FTG TG PE 0.0
2 -1.0 0.0 40.6 0.0 0.261 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 40.6 0.0 4.0 psi, 31.7 gprn
2A -1.0 0.0 36.6 0.0
Pipe: 3 31.7 1.025 PL 2.00 PF 1.1
2A -1.0 0.0 36.6 0.0 12.3 150 FTG E FE 0.0
U.1 -1.0 H.S. 35.5 5.0 0.225 TL 5.00 PV
Pipe: 4 26.7 1.025 PL 2.00 PF 0.8
U.1 -1.0 H.S. 35.5 5.0 10.4 150 FTG E FE -1.3
R 2.0 0.0 33.4 0.0 0.164 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 33.4 0.0 5.0 psi, 26.7 gpm
P 2.0 0.0 28.4 0.0
Pipe: 6 26.7 1.590 PL 45.00 PF 1.2
P 2.0 0.0 28.4 0.0 4.3 150 FTG E4L FE 1.3
U.2 -1.0 0.0 28.4 0.0 0.019 TL 63.00 PV
Pipe: 7 26.7 1.505 FL 10.00 PF 1.2
U.2 -1.0 0.0 28.4 0.0 4.8 150 FTG 3E2LC FE -0.9
U.3 1.0 0.0 26.4 0.0 0.025 TL 48.00 PV
Pipe: 8 26.7 1.025 FL 1.00 PF 0.7
U.3 1.0 0.0 26.4 0.0 10.4 150 FTG E FE 0.0
U.4 1.0 0.0 25.7 0.0 0.164 TL 4.00 PV
Pipe: 9 26.7 1.025 PL 2.50 PF 0.9
U.4 1.0 0.0 25.7 0.0 10.4 150 FTG E FE -1.1
3 3.5 0.0 23.7 0.0 0.164 TL 5.50 PV
Pipe: 10 26.7 1.049 FL 3.00 PF 1.8
3 3.5 0.0 23.7 0.0 9.9 120 FTG C FE -1.3
4 6.5 0.0 20.6 0.0 0.221 TL 8.00 PV
Pipe: 11 26.7 1.101 PL 17.00 PF 3.9
4 6.5 0.0 20.6 0.0 9.0 150 FTG 2E3R FE -1.3
5 9.5 0.0 15.4 0.0 0.116 TL 34.00 PV
Pipe: 12 14.9 1.101 FL 12.50 PF 1.3
5 9.5 0.0 15.4 0.0 5.0 150 FTG 2ET2R FE -4.5
6 20.0 0.0 9.5 0.0 0.040 TL 33.50 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE: 2/14/2011 C:\HASS74\C4519-F3.SDF
JOB TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. FT DISC. VEL(FFS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 14.9 1.101 PL 12.00 PF 1.0
6 20.0 0.0 9.5 0.0 5.0 150 FTG ETR FE 0.0
7 20.0 0.0 8.5 0.0 0.040 TL 25.00 PV
Pipe: 14 11.2 1.101 PL 21.00 PF 0.8
7 20.0 0.0 8.5 0.0 3.8 150 FTG 2T2R PE 0.0
8 20.0 0.0 7.8 0.0 0.023 TL 33.00 PV
Pipe: 15 13.0 1.101 PL 25.00 PF 1.0
8 20.0 0.0 7.8 0.0 4.4 150 FTG TR FE 0.2
8A 19.5 4.9 7.0 13.0 0.031 TL 31.00 PV
Pipe: 16 -1.8 1.101 PL 9.50 PF 0.0
8 20.0 0.0 7.8 0.0 0.6 150 FTG B. FE 0.0
9 20.0 0.0 7.8 0.0 0.001 TL 10.50 PV
Pipe: 17 13.7 1.101 PL 0.50 PF 0.2
9 20.0 0.0 7.8 0.0 4.6 150 FTG TR FE 0.2
9A 19.5 4.9 7.8 13.7 0.034 TL 6.50 PV
Pipe: 18 -15.4 1.101 PL 9.50 PF 0.4
9 20.0 0.0 7.8 0.0 5.2 150 FTG R FE 0.0
10 20.0 0.0 8.2 0.0 0.042 TL 10.50 PV
Pipe: 19 0.0 1.101 FL 8.00 PF 0.0
10 20.0 0.0 8.2 0.0 0.0 150 FTG 2TR FE 0.2
10A 19.5 0.0 8.4 0.0 0.000 TL 19.00 PV
Pipe: 20 -15.4 1.101 PL 0.50 PF 0.1
10 20.0 0.0 8.2 0.0 5.2 150 FTG R FE 0.0
11 20.0 0.0 8.3 0.0 0.042 TL 1.50 PV
Pipe: 21 -3.7 1.101 FL 53.00 PF 0.3
11 20.0 0.0 8.3 0.0 1.2 150 FTG 2E4T FE 0.0
7 20.0 0.0 8.5 0.0 0.003 TL 87.00 PV
Pipe: 22 -11.7 1.101 PL 10.50 PF 0.5
11 20.0 0.0 8.3 0.0 3.9 150 FTG EAR FE 4.5
12 9.5 0.0 13.3 0.0 0.025 TL 19.50 PV
Pipe: 23 -11.7 1.101 FL 52.50 PF 2.1
12 9.5 0.0 13.3 0.0 3.9 150 FTG 5T5R FE 0.0
5 9.5 0.0 15.4 0.0 0.025 TL 82.50 PV
.7
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
DATE: /14/20l1 C:\HAS0'74\C4519-F3.0'DF
J09 TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
NOTES (HASS):
Calculations were performed by the HASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.001 gpm and a maximum
imbalance at any node of 0.018 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 13.1 ft/sec at pipe 1.
PIPE FITTINGS TABLE
Pipe Table Name: FSS.PIP
PAGE: A MATERIAL: SCH40 HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E P R K C L B L
Eli Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE: '2/14/2011 C:\HASS74\C4519-P3.SDF
JOS TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE: 2/14/2011 C:\HASS74\C4519-P3.SDF
J08 TITLE: ROCKROSE PLAN 3 TWO HEAD CALC-2nd FLOOR
WATER SUPPLY ANALYSIS
Static: 63.00 psi Resid: 57.60 psi Flow: 500.0 gpm
80.0
70.0
60.
G
A
U
G 50
E
P 40.
R
E
30.
S
U
R
E 20.
p 10.
S
LEGEND
Available pressure
62.97 psi @ 31.7 gpm
Required pressure
52.07 psi @ 31.7 gpm
Source Supply Curve
System Demand Curve
an
j 7C
DL
ON
II
0.
-14.71 I I I I I I I 1 I
20C300 400 500 600 700 800 900 1000
FLOW (GPM)
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1
DATE: 2/14/2011 C:\HASS74\C4519-P3.SDF
JOS TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
* WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS.
TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 63.0 57.6 500.0 63.0 25.0 51.9
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 25.0 GPM
TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM
OTHER HOSE STREAM ALLOWANCES 5.0 GPM
TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE
(FT) (PSI) (GPM)
1 -1.0 SOURCE 51.9 25.0
2 -1.0 - - - - 44.4
2A -1.0 - - - - 40.4 - - -
U.1 -1.0 HOSE STREAM 39.7 5.0
R 2.0 - - - - 37.9 - - -
P 2.0 - - - - 32.9
U.2 -1.0 - - - - 33.5
U.3 1.0 - - - - 31.9
U.4 1.0 - - - - 31.6
3 3.5 - - - - 29.9
4 6.5 - - - - 27.6 - - -
5 9.5 - - - - 24.0
6 20.0 - - - - 18.7
7 20.0 - - - - 18.2 - - -
8 20.0 - - - - 17.9
8A 19.5 - - - - 18.1 - - -
9 20.0 - - - - 17.8 - - -
9A 19.5 - - - 18.0 - - -
10 20.0 - - - - 17.7
10A 19.5 K= 4.90 16.7 20.0
11 20.0 - - - - 17.8 - - -
12 9.5 - - - - 22.7
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2
DATE: 2/14/2011 C:\HASS74\C4519-P3.SDF
JOB TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 25.0 0.995 PL 35.00 PF 7.4
1 -1.0 SRCE 51.9 (N/A) 10.3 150 FTG TG FE 0.0
2 -1.0 0.0 44.4 0.0 0.169 TL 44.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE
2 -1.0 0.0 44.4 0.0 4.0 psi, 25.0 gpm
2A -1.0 0.0 40.4 0.0
Pipe: 3 25.0 1.025 FL 2.00 PF 0.7
2A -1.0 0.0 40.4 0.0 9.7 150 FTG E FE 0.0
U.1 -1.0 H.S. 39.7 5.0 0.146 TL 5.00 PV
Pipe: 4 20.0 1.025 PL 2.00 PF 0.5
U.1 -1.0 H.S. 39.7 5.0 7.8 150 FTG E FE -1.3
R 2.0 0.0 37.9 0.0 0.096 TL 5.00 PV
Pipe: 5 FIXED PRESSURE LOSS DEVICE
R 2.0 0.0 37.9 0.0 5.0 psi, 20.0 gpm
P 2.0 0.0 32.9 0.0
Pipe: 6 20.0 1.590 PL 45.00 PF 0.7
P 2.0 0.0 32.9 0.0 3.2 150 FTG E4L FE 1.3
U.2 -1.0 0.0 33.5 0.0 0.011 TL 63.00 PV
Pipe: 7 20.0 1.505 PL 10.00 PF 0.7
U.2 -1.0 0.0 33.5 0.0 3.6 150 FTG 3E2LC FE -0.9
U.3 1.0 0.0 31.9 0.0 0.015 TL 48.00 PV
Pipe: 8 20.0 1.025 FL 1.00 PF 0.4
U.3 1.0 0.0 31.9 0.0 7.8 150 FTG E FE 0.0
U.4 1.0 0.0 31.6 0.0 0.096 TL 4.00 PV
Pipe: 9 20.0 1.025 FL 2.50 PF 0.5
U.4 1.0 0.0 31.6 0.0 7.8 150 FTG E FE -1.1
3 3.5 0.0 29.9 0.0 0.096 TL 5.50 PV
Pipe: 10 20.0 1.049 PL 3.00 PF 1.0
3 3.5 0.0 29.9 0.0 7.4 120 FTG C FE -1.3
4 6.5 0.0 27.6 0.0 0.130 TL 8.00 PV
Pipe: 11 20.0 1.101 FL 17.00 PF 2.3
4 6.5 0.0 27.6 0.0 6.7 150 FTG 2E3R FE -1.3
5 9.5 0.0 24.0 0.0 0.068 TL 34.00 PV
Pipe: 12 10.8 1.101 FL 12.50 PF 0.7
5 9.5 0.0 24.0 0.0 3.6 150 FTG 2ET2R FE -4.5
6 20.0 0.0 18.7 0.0 0.022 TL 33.50 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3
DATE:' 2/14/2011 C:\HASS74\04519-F3.SDF
JOB TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS.
END ELEV. NOZ. PT DISC. VEL(FFS) HW(C) (FT) SUM.
NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 10.8 1.101 PL 12.00 PF 0.5
6 20.0 0.0 18.7 0.0 3.6 150 FTG ETR FE 0.0
7 20.0 0.0 18.2 0.0 0.022 TL 25.00 PV
Pipe: 14 6.3 1.101 PL 21.00 PF 0.3
7 20.0 0.0 18.2 0.0 2.1 150 FTG 2T2R FE 0.0
8 20.0 0.0 17.9 0.0 0.008 TL 33.00 PV
Pipe: 15 0.0 1.101 FL 25.00 PF 0.0
6 20.0 0.0 17.9 0.0 0.0 150 FTG TR PE 0.2
8A 19.5 0.0 18.1 0.0 0.000 TL 31.00 PV
Pipe: 16 6.3 1.101 FL 9.50 PF 0.1
6 20.0 0.0 17.9 0.0 2.1 150 FTG R PE 0.0
9 20.0 0.0 17.8 0.0 0.008 TL 10.50 PV
Pipe: 17 0.0 1.101 FL 0.50 PF 0.0
9 20.0 0.0 17.8 0.0 0.0 150 FTG TR FE 0.2
9A 19.5 0.0 18.0 0.0 0.000 TL 6.50 PV
Pipe: 18 6.3 1.101 FL 9.50 PF 0.1
9 20.0 0.0 17.6 0.0 2.1 150 FTG R FE 0.0
10 20.0 0.0 17.7 0.0 0.008 TL 10.50 PV
Pipe: 19 20.0 1.101 PL 8.00 PF 1.3
10 20.0 0.0 17.7 0.0 6.7 150 FTG 2TR FE 0.2
10A 19.5 4.9 16.7 20.0 0.068 TL 19.00 PV
Pipe: 20 -13.7 1.101 PL 0.50 PF 0.1
10 20.0 0.0 17.7 0.0 4.6 150 FTG R FE 0.0
11 20.0 0.0 17.8 0.0 0.034 TL 1.50 PV
Pipe: 21 -4.5 1.101 PL 53.00 PF 0.4
11 20.0 0.0 17.6 0.0 1.5 150 FTG 2E4T PE 0.0
7 20.0 0.0 18.2 0.0 0.004 TL 87.00 PV
Pipe: 22 -9.2 1.101 PL 10.50 PF 0.3
11 20.0 0.0 17.8 0.0 3.1 150 FTG E2R FE 4.5
12 9.5 0.0 22.7 0.0 0.016 TL 19.50 PV
Pipe: 23 -9.2 1.101 FL 52.50 PF 1.3
12 9.5 0.0 22.7 0.0 3.1 150 FTG 5T5R FE 0.0
5 9.5 0.0 24.0 0.0 0.016 TL 82.50 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4
/ DATE: 2/14/2011 C:\HASS74\C4519-P3.SDF
JOB TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
NOTES (HASS):
Calculations were performed by the HASS 8.1 computer program
under license no. 16080621 granted by
HRS Systems, Inc.
208 South Public Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provide an average
imbalance at each node of 0.008 gpm and a maximum
imbalance at any node of 0.152 gpm.
Total pressure at each node is used in balancing the system.
Maximum water velocity is 10.3 ft/sec at pipe 1.
PIPE FITTINGS TABLE
Pipe Table Name: FSS.PIP
PAGE: A MATERIAL: SCH40 HWC: 120
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00
PAGE: H MATERIAL: CPVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T R K C L B L
Eli Tee TEERUN COUPLG EL45
1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00
PAGE: I MATERIAL: CPPR-L HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Ell Tee
1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00
1.505 6.00 12.00 3.00 14.00 2.00 2.00 0.00 0.00
PAGE: J MATERIAL: S40PVC HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee
1.590 6.00 12.00 3.00 14.00 8.00 2.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5
DATE:. 2/14/2011 C:\HASS74\C4519-P3.SDF
JOB TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
PAGE: K MATERIAL: CPPR-K HWC: 150
Diameter Equivalent Fitting Lengths in Feet
(in) E T L C B G A D
Eli Tee L
0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6
DATE:'2/14/2011 C:\HASS74\C4519-P3.SDF
JOB TITLE: ROCKROSE PLAN 3 ONE HEAD CALC-2nd FLOOR
WATER SUPPLY ANALYSIS
Static: 63.00 psi Resid: 57.60 psi Flow: 500.0 gpm
80.0
70.0
1
60.(
G
A
50.
E
P 40.0
R
E
30.0
S
U
R
F 20.0
LEGEND
Available pressure
62.96 psi @ 25.0 gpm
Required pressure
51.87 psi @ 25.0 gpm
Source Supply Curve
System Demand Curve
p 10.0
S
1
0.0
-14.7l I 1 I I 1 I I I I
20C300 400 500 600 700 800 900 1000
FLOW (GPM)
r.
/ Bulletin 006 Rev. E
Reliable Model RFC43 (SIN RA061 2)
Model RFC49 (SIN RA061 6)
Residential Flat Concealed
Sprinklers
ni
A Residential Flat Concealed
Sprinkler engineered fora minimum
design density of 0.05 gpm/ft2 with
low GPM requirements.
Features
Very low water flow requirements.
½" (13mm) Total adjustment.
Thread-On/Thread-Off or Push-On/Thread
Off cover attachment option.
Smooth aesthetic ceiling profile.
Available in brass, chrome and black plated
or painted finishes.
Listings & Approval
Listed by Underwriters Laboratories, and
certified by UL for Canada (cULus)
NYC MEA 258-93-E
UL Listing Categories
Residential Automatic Sprinklers
UL Guide Number
VKKW
Product Description
Model RFC43 and RFC49 concealed Residential Sprin-
klers are fast response residential fusible solder link au-
tomatic sprinklers. Residential sprinklers differ from stan-
dard sprinklers primarily in their response time and water
distribution patterns.
Model RFC43 and RFC49 sprinklers discharge water
in a hemispherical pattern below the sprinkler deflector.
Residential distribution patterns are higher and generally
contain a finer droplet size than standard sprinkler pat-
terns.
The combination of speed of operation and high dis-
charge pattern required for residential sprinklers has dem-
onstrated, in fire testing, an ability for controlling residen-
tial fires, and thereby providing significant evacuation time
for occupants.
The RFC43 and RFC49 Sprinklers provide the best form
of fire protection by combining an attractive appearance
and ½" (13mm) of cover adjustment for ease of installa-
tion. The small diameter cover plate is easily and posi-
tively attached and blends into the ceiling, concealing the
most dependable fire protection available, an automatic
sprinkler system.
The RFC43 and RFC49 are UL Listed Residential Sprin-
klers to be installed in the residential portions of any occu-
pancy in accordance with NFPA 13, 13R, & 13D.
The RFC43 and RFC49 can reduce the need for precise
cutting of drop nipples. The threaded cover plate assem-
bly can be adjusted without tools to fit accurately against
the ceiling. The fire protection system need not be shut
down to adjust or remove the cover plate assembly.
Application and Installation
The RFC43 and RFC49, for residential installations, use a
165°F (74°C) fusible solder link in a tuning fork style sprin-
kler frame with a drop-down deflector. This assembly is re-
cessed into the ceiling and concealed by a flat cover plate.
The cover plate is attached to the skirt, using 135°F (57°C)
ordinary temperature classification solder. When the ceil-
The Reliable Automatic Sprinkler Go,, Inc,,103 Fairview Park Drive, Elmsford, New York 10523
/
I.
ing temperature rises, the solder holding the cover plate
releases the cover allowing the deflector to drop into posi-
tion and exposing the sprinkler inside to ceiling tempera-
ture. The subsequent operation of the solder link opens
the waterway and causes the deflector to drop into posi-
tion to distribute the discharging water in a hemispherical
pattern below the sprinkler deflector. Any adjustment of
thread engagement between the cover plate and cup will
assure that the drop-down deflector is properly located
below the ceiling. The residential distribution pattern con-
tains a finer droplet size than a standard sprinkler, and the
pattern produces significantly higher wall wetting.
After a 2/8 inch diameter hole is cut in the ceiling, the
sprinkler is to be installed with the Model FC Wrench.
When installing a sprinkler, the wrench is first positioned
into the sprinkler/cup assembly and around the hexagonal
body of the sprinkler frame, The Wrench must bottom out
against the cup in order to ensure proper, safe installation.
The sprinkler is then tightened into the pipe fitting. When
inserting or removing the wrench from the sprinkler/cup
assembly, care should be taken to prevent damage to the
sprinkler. DO NOT WRENCH ON ANY OTHER PART OF
THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 AND
RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED
ONLY WITH 135°F RATED COVERS.
Note: A leak tight ½" NPT (R1/2) sprinkler joint can be ob-
tained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not
tighten sprinklers over maximum recommended torque. It
may cause leakage or impairment of the sprinklers.
Cover assemblies provide up to 1/2" (13mm) of adjust-
ment. Turn the cover clockwise until the flange is in con-
tact with the ceiling. For the push-on/thread-off option, the
cover assembly is pushed onto the cup and final adjust-
ment is made by turning the cover clockwise until the skirt
flange makes full contact with the ceiling. Cover removal
requires turning in the counter-clockwise direction.
In ceilings that have a plenum space above the sprinkler,
the plenum space may have neutral or negative pressur-
ization but must not be positively pressurized. Inspect all
sprinklers after installation to ensure that the gap between
the cover plate andr ceiling and the 4 slots in the cup are
all open and free from any air flow impediment.
Temperature Rating
Sprinkler Cover Plate Max. Ambient Temp.
165°F/740C 1350F/570C 100°F/380C
Installation Data: RFC43 (SIN RA061 2)
Thread
Size
inch (mm)
K Factor
Sprinkler
Spacing
ft. (m)
Maximum
Distance to
Wail
Minimum
Distance between
sprinklers
Minimum Required
Sprinkler Discharge
Flow Press.
ft. (m) ft. (m) gpm (Lpm) psi (bar)
112"(15mm) 4.3 12x 12(3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8(0.54)
½" (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63)
½" (15mm) 4.3 16 x 16 (4.90.9) 8(2.43) 8(2.43) 13 (49) 9,1 (0.63)
½" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(1.21)
½'(15mm) 4.3 20x20(6.0x6.0) 10(3.05) 8(2.43) 21(79) 23.8(1.64)
Note: 1 bar= 100 Kpa
Installation Data: RFC49 (RA0616)
Thread Sprinkler Maximum Minimum Minimum Required
Size K Factor Spacing Distance to Distance between Sprinkler Discharge
Flow Press. inch (mm) ft. (m) Wail sprinklers
ft. (m) ft. (m) gpm (Lpm) psi (bar)
W(15mm) 4.9 12x 12(3.6x3.6) 6(1.83) 8(2.43) 13(49) 7.0(0.48)
W(l5mm) 4.9 14x 14(4.3x4.3) 7(2.13) 8(2.43) 13(49) 7.0 (0.48)
½" (15mm) 4.9 16 x 16 (4.9x4.9) I 8(2.43) 8(2.43) 13(49) 7.0(0.48)
1/2"(15mm) 4.9 18x18(5.5x5.5) 9(2.74) 8(2.43) 17(64.3) 12.0(0.83)
1/2"(15mm) 4.9 20x20(6.0x6.0) [ 10 (3.05) 8(2.43) 20 (75.7) 16.7 (1.14)
Note: 1 bar = 100 KDa
FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035.
2.
I
-f
'Maintenance
Model RFC43 and RFC49 Concealed Sprinklers should
be inspected quarterly and the sprinkler system main-
tained in accordance with NFPA 25. Do not clean sprin-
klers with soap and water, ammonia or any other clean-
ing fluids. Remove dust by using a soft brush or gentle
vacuuming. Remove any sprinkler cover plate assembly
which has been painted (other than factory applied) or
damaged in any way. A stock of spare sprinklers should
be maintained to allow quick replacement of damaged or
operated sprinklers. Prior to installation, sprinklers should
be maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non-operation.
Model RFC43 and RFC49 Residential
Concealed Sprinkler Specification
Sprinklers shall be cULus Listed low flow residential con-
cealed sprinklers with drop-down deflector and adjust-
able flat cover plate engineered for a minimum design
density of 0.05 gpm/ft2. Sprinkler frame and deflector
shall be of bronze frame construction having a ½" NPT
thread. Thermal element shall consist of an approved
black-painted beryllium-nickel fusible solder link with
symmetric lever mechanism, maintaining a Teflon-coated
Belleville spring washer and machined brass cap water
seal assembly containing no plastic parts. Sprinkler
K-factor shall be nominal 4.3 (62.4), having a 7/16" orifice.
Temperature rating shall be Ordinary 165°F (740C); cover
plate temperature rating to be 135°F (570C). Cover plate
assembly shall consist of a brass cover plate and copper
alloy retainer flange allowing a ½" cover plate adjust-
ment. Any secure engagement between the cover plate
and the cup will assure that the drop-down deflector is
properly located below the ceiling. A plastic protective
cap shall be provided and factory installed inside the
sprinkler cup to protect the drop-down sprinkler deflec-
tor from damage, which could occur during construction
before the cover plate is installed. Standard cover fin-
ish: [Chrome] [White] [Specialty - specify]. Residential
concealed sprinklers shall be Reliable Model RFC43,
SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616
(Bulletin 006),
Ordering Information
Specify:
Sprinkler Model
Cover Plate Finish
Thread-On or
Push-On Feature
(I) Other colors and finishes avail-
able. Consult factory for details,
Note: Paint or any other coatings
applied over the factory finish will
void all approvals and warran-
ties.
Cover Plate Finishes (1)
Standard Finishes
Chrome
White
Special Application
Finishes
Bright Brass
Black Plating
Black Paint
Off White
Satin Chrome
x 1/2" REDUCING
TEE OR ELBOW
" [66./mm] 0/A.
[58.7mm] D/A - ________________ HOLE IN CEILING
CUP
\\\\\\
/
CEILING /
" [12./mm] MAX. T
COVER ADJUSTMENT
COVER PLATE
ASSEMBLY SPRINKLER
2" [50.8mm] MAX.
FACE OF FITTING
TO FACE OF CEILING
DIMENSION
3k" 0/A. 3/16" J
[84. 1mm] [4.8mm]
OOGFGO?
iJOO.Vj
COVER PLATE. 1/2" [12.7mm] ADJUSTMENT
3,
R ---liable
Bulletin 135 Rev.G
Model Fl
Residential Sprinklers for
Design Density of .05 gpmlft2
Model Fl Res Sprinklers engineered for the lowest flows
to meet the minimum design density of .05 gpmM , .- -. . "'•.L'".
(t.
Fl Res 30,49,58&76 Fl Res 30,49,58&76
Recessed Pendent/ F1 Recessed Pendent/ FP
Fl Res 30, 49 , 58 & 76
CCP Pendent
Fl Res 44 SWC Fl Res 40 Recessed
HSW/F2
The low flow Fl Res sprinklers are specially
engineered for fast thermal response to meet the
sensitive fire protection application needs of the latest
residential market standards (UL 1626 Standard). Upon
fire conditions, rising heat causes a sprinkler's
heat-sensitive glass-bulb to shatter, releasing the
waterway for water flow onto the deflector, evenly
distributing the discharged water to control a fire.
Technical Data:
Thermal Sensor: Nominal 3mm glass-bulb
Sprinkler Frame: Brass Casting
Sprinklers' Pressure Rating: 175 psi
Factory Hydrostatically Tested to 500 psi
Thread Size: ½" NPT (R½)
K-Factor: 3.0 (Actual) - Fl Res 30 Pendent Sprinkler
4.9 (Actual) - El Res 49 Pendent Sprinkler
5.8 (Actual) - Fl Res 58 Pendent & HSW Sprinkler
7.6 (Actual) - Fl Res 76 Pendent Sprinkler
4.4 (Actual) - Fl Res 44 HSW Sprinkler
4.0 (Actual) - Fl Res 410 HSW Sprinkler
Density: Minimum 0.05 gpm/ft2
Application
Model El Res Sprinklers are used for Residential Fire
Protection according to UL 1626 Standard*. Be sure
that orifice size, temperature rating, deflector style and
sprinkler type are in accordance with the latest
published standards of The National Fire Protection
Association or the approving authority having
jurisdiction.
1fl. Fir',i, Pirk nrixtp PImcfrrr NOW Yrrk 1fl9
Types:
F1 Res 30Pendent
Fl Res 30 Recessed Pendent/F2
Fl Res 30 Recessed Pendent/FP
Fl Res 49 Pendent
Fl Res 49 Recessed Pendent/F1
Fl Res 49 Recessed Pendent/FP
Fl Res 58 Pendent
Fl Res 58 Recessed PendentJFl
Fl Res 58 Recessed Pendent/FP
Fl Res 76 Pendent
Fl Res 76 Recessed Pendent/F1
Fl Res 76 Recessed Pendent/FP
Fl Res 30 CCP Pendent
Fl Res 49 CCP Pendent
Fl Res 58 COP Pendent
Fl Res 76 CCP Pendent
F1 Res 44HSW
Fl Res 44 Recessed HSW/F2
F1 Res 58HSW
Fl Res 58 HSW Recessed HSW/F2
21.F1 Res 44SWC
Fl Res 40 HSW
Fl Res 40 Recessed HSW/F2
Listings & Approvals
1. Listed by Underwriters Laboratories Inc. and
UL Certified for Canada (cULus) I 2. NYC MEA 258-93-E
Slope Ceiling Approvals: Refer to Bulletin 035
Sprinklers for .10 Density: Refer to Bulletin 176
UL Listing Category
Residential Automatic Sprinkler
UL Guide Number
VKKW
Patents
US Patent No. 6,516,893 applies to the
Model Fl Res 49 & 58 Pendent Sprinklers
Product Description
Model Fl Res Pendent sprinklers (Figs. 1, 2,3, &4) ar
fast response sprinklers combining excellent durability
high sensitivity glass-bulb and low profile decorative
design. The Fl Res Horizontal Sidewall sprinklers (Figs
5,6 & 7) are equally attractive when above ceiling piping
cannot be used.
The 3mm glass-bulb pendent sprinklers permit th€
efficient use of residential water supplies for sprinkle i
coverage in residential fire protection design.
Thc PDlilhIø Ai,tmth, nrinkIør (r. Ind'
Fl Res 44&58
Recessed HSW/F2
2 ?/4 tZ I& (57.2m**,J
CM. (4t2,J
TmLR NQEf S
FA n77w#; 70 CUMC Doeam
T l,EJt
135P602 2 27/Jr CM.
(72.2nj
13.5FGOJ
Installation
Models Fl Res sprinklers are to be installed as
* shown. Model Fl, F2 and FP Escutcheons, illustrated
herewith, are the only recessed escutcheons to be used
with Model Fl Res sprinklers. Use of any other
recessed escutcheon will void all approvals and
warranties. For installing Model Fl Res Pendent
sprinklers use only the Model D sprinkler Wrench; for
installing Models Fl Res Recessed Pendent, COP &
Model Fl Res 30,49,58 & 76 Pendent
SWC sprinklers use only the Model GFR2 sprinkler
wrench; for installing Model Fl Res Recessed HSW
sprinklers use only the Model GFR2 Sprinkler Wrench.
Use of wrenches other than those specified may
damage these sprinklers. Install Fl Res 44 and 40 HSW
with a ceiling to deflector distance of 4"- 12". Flow arrow
on deflector must point away from near wall and "Top"
marking must face ceiling.
Model Fl Res 30 Recessed
Pendent /F2
Model Fl Res 49,58 & 76
Recessed Pendent I Fl
iI
—
F 1 escutcheon, 3/411 (19mm) adjustment
Fig. 1 Fig. 2
Escutcheon*. Fl or F2. Data:
Adjustment "A" Face of fitting to
Type Inch (mm) Inch (mm) ceiling
Inch (mm)
Fl 3/ (19.0) Min.= 3/4' (19.1)
Max. =134" (38.1) /6 - X6 (4.7 - 24.0)
F2 Y2(12.7) Min.=15/6"(23,8)
Max.=1%" (38.1)
3X61<6(47 17.4)
* Note: Escutcheons Fl or F2 may be used with
Model Fl Res 49, 58 & 76 Recessed Pendent
2.
Technical Data: Fl Res 30 Pendent and Recessed Pendent
Thread
Size
Nominal
Orifice
Inch
(mm)
I Sprinkler
Temp.
Rating
Max Max.
pressure
(bar)
I Temp.
Actual
K
Factor
Sprinkler i
Length Inch
(mm) I °c °F
"NPT
-
'' (8 2) 155 68 LLi1L 100 38 30 2,25 (57)
Deflector - to - ceiling
Maximum 1" (25mm) to 4" (100mm)
Max. Sprinkler Flow Pressure Sprinkler
I Spacing
ft_(m)
gpm (Lpm) psi (bar) Identification
Number (SIN)
12x 12 (3.6x3.6) 1 8 (30.3) 7.0(0.48)
R3511 14 x 14 (4.3x4.3) 1 10(37.8)
Technical Data: Fl Res 49 Pendent and Recessed Pendent
Nominal Sprinkler J Max Max.
_-__
Actual Sprinkler 1, Thread Orifice Temp. Pressurej Ambient I Length
Size Inch Rating I psi Temp. Factor' Inch
L <c I °c -i (mm) OF °C (bar) (mm)
)4"NPT 155 68
175! 79 171(12, 1100138
11501 66 4,9 [2.25 (57)
Deflector - to - ceiling
Maximum 1" (25mm) to 4" (100mm)
Max. Sprinkler
Spacing
ft (m)
Flow
gpm (Lpm)i
Pressure
psi (bar )
Sprinkler 1 Identification
NuTj?qL(SIN
12 x 12 (3.6x3.6) 7.0(0.48)
R3516
[14 x 14 (4.3x4.3) 13(49) 7.0(0.48)
L16X16(4.9X4.9) 13 _(49) _pJç4)I
I 18x 18(5.5x5.5) 17(64.3) 1 12.0 (0.83)
20 x 20 (6.1 x6.1) 1 20 (75.7) 16.7(1.14)I
*Deflector - to - ceiling
Maximum 4" (100mm) to 8" (203mm)
Max. Sprinkler
Spacing Flow
gpm (Lpm)
Pressure
psi (bar)
Sprinkler
Identification
Number (SIN)
12 x 12 6x3j 15 (57) 9,4 (0.65)
R3516
20.2(1.4)
14 x 14 (4.3x4.3) 12L. 10.6(0.73)
16x 16(4.9x4.9) 17(64.3) 12.0 (0.83)
18 x 18 _1 7_
20 x 20 (6.1x6.1) 22(83.2)
*NOte: The Fl Res 49 pendent and recessed pendent
residential sprinklers can be installed per NFPA 13 in
beamed ceilings meeting the following criteria:
Maximum beam depth = 7" (178mm)
Beam spacing ator greater than 7.5 ft. (2.3m) on center.
Technical Data: Fl Res 58 Pendent and Recessed Pendent
Nominal Sprinkler Max. Max. Sprinkler
Thread Orifice I Temp. Pressure Ambient K Length
Size Inch Rating psi Temp. I Factor Inch
°F I 'c F I °c (mm) (bar) (mm)
[½" NPT %' (13) 155 68
j_175 (12) 100 I 38 I 5.8 2.25 (57) (R½) 175 I 79 150! 66
Max. Sprinkler
Spacing
it (m)
flow I gpm (Lpm)
Pressure
psi (bar)
Ceiling -to-
Deflector
Inch (mm)
Sprinkler
Identification
Nu(
I_12x12(3.6x3.6) 16(61) 7.6(0.53)
(25-1 00) R3513
14 x 14 (4.3x4.3) t 16(61) 7.6(0.53)
16 x 16 (4.9x4.9) I _jj 1-4j 7.6(0.53)
18 x 18 (5.5x5.5) 1 19(72) I 10.8(0.7
20 x 20 (6. 1 x6. 1) ! 22(83.3) 14.4(1.0)
CI
p
Technical Data: Fl Res 76 Pendent and Recessed Pendent
Nominal Wder Max. Max. xi1der
Thread Orifice Tenii Piessue Aiöe1 K Length
She Inch Ig psi Inch
Facr
°F °c °F (mm) (bar) (mm)
%"NPT
(R3/4)
%2'
(13.5)
155!
175!
68
79 175(12) 100
150
38
I 66 7.6 2.25(57)
Max. Sprinkler
Spacing
ft (m)
Flow
gpm (Lpm)
Pressure
psi (bar)
Sprinkler
Identification
Number (SIN)
12 x 12 (3.6x3.6) 21 7.6(0.53)
R7618
14 x 14 (4.3x4.3) 21 7.6(0.53)
16 x 16 (4.9x4.9) 21 7.6(0.53)
18 x 18 (5.5x5.5) 21 7.6
20x20(6ix6.1) . 23 [ 9.2(0.63)
Model Fl Res 30,49,58 & 76
CCP Pendent
Model Fl Res 30,49,58 & 76
Recessed Pendent I FP
FP push-on/thread-off
escutcheon
2 5/8 [66. 7mm] 0/4.
2 5/16' 0/A. - - I-IDLE IN CEILING
[58.7mm] - -
CUP
H ........... ................... i"i/2" REDUCER
CUP
CEILING
471~ MAX. FACE OF FITTING
1/4/31.5mmJ
To FACE OF CEILING
DIMENSION
COVER ADJUSTMENT / HEIGHT
3 5/76 CIA.
135FG04D [84.7mm]
Fl RES 30, 49, 58 & 76 COP PEND.
Fig. 3
NOTE: The Fl Res 76 will use a 1" x 3/4" reducer.
2 5/8 ELI. 1-7.-] HOLE IN CEILING
2 3/16 ELI.
(5&7Inm) T - -----------IX
I /
/
CEILING
FACE OF RMNG TO FACE OF CEMM
DWENSOV
rp
Fig.4
4
CCP ODtions Data:
Cover Adjustment CCP Height
Inch (mm) Inch (mm)
y2 (12.7)
(79) %(19)
FP Data "A":
"A" FP Position Inch (mm)
Max. Recessed X6 (11)
Mm. Recessed % (24)
Technical Data: Fl Res 30 CCP Pendent and Recessed Pendent I FP
Thread
Size
Nominal
Orifice
Inch
Siodrildwi
Teni
L H
ccp'
Assently
I
_ I
Ten.
K
j FactorInch
ñ1der
Length
(MM)
1/2 0
NPT 2)/"(82)
_
1551 68!1351
I
Iii
57 175(12) 100 38 1 3.0 225
(57)
Max. Sprinkler Rowpressure I Sprinkler
Spacing
ft (m) (Lpm) psi (bar) I Identification
Number (SIN) _____
12 x 12 (3.6xa1D.3) I 7.0(0.48)
13.4 R3511 14 x 14 (4.3x4.3) Iij.j4.t)
Technical Data: Fl Res 49 CCP Pendent and Recessed Pendent I FP
Thread
Size
Nominal
Oiffice
Inch
Spñ1des
Terqi
Ring
OCP
Asser"
Ten'
.
Max
P ressue
MEM I l I
Mti1 K
Je1 Factor i Length
kidi
(mm) (niii)
NPT X6 (11) 15516811351 I 57 175(12)
I 100138 2.25
(R½)
Spacing
Max. Sprinkler Flow Press Sprinkler
ft (m) gpm (Lpm) psi (bar) Nunib(slN)
Identification
i2i2..(36x35L t3(49L _LQ0.48)
14 x 14 (4.3x4.3) L 1349L_. L1(fl.48)_.
I 16 x 16 (4.9x4.9) I 14(53) 8.2 R3516
18 x 18 (5.5x55Lt 18 (6BJL .J3.5_!Q.23L.
_____________ _____ I, 20x20(6.1x6.1) L_20i5iL, _i.57(1.i4J_______ suable for installaon in ceilings which have
posftive pressure in the space above.
Technical Data: Fl Res 58 CCP Pendent and Recessed Pendent/FP
Nominal *inkler' ccpm
ASS5I1tIYI
1
Max
"der Thread
Size
Orifice
Inch
Ten
Rkig Teff Ratirm
Pressue Mtielll K
psi I Teni Fador
Length
Inch
1/2" NPT 2'(13) 155 68 135 57 U WL
Max. Sprinkler
'Spacing
ft (m)
2( 12x13.6x3.6)
Row
gpm(Lpm)
- --__
16(61)
Pressure
PSI (bar)
.75a53)_
Sprinkler
Identification
R3513
1
14 x 14 (4.3x4.3) 16(61) 7,6(0.53)
16 x 16 (4.9x4.9) 1 16(61) - 7.6(0.53)
18x18.5x5.5) 1 19(72) 10.8(0.75)
20x20(6.1x6.1) 1_....22183.3.L.1 14.4 (1.0)
Technical Data: Fl Res 76 CCP Pendent and Recessed Pendent/FP
Nominal Sprilde CCP r Max, Max
Thread
Size Inch
Orifice!Ass Temp.T Flatir!J Ratim
Aessue
psi
Mt1I K
Teni Fador Length
(mm) (bar) iH _ 'F
3/4" NPT
_____ (R3/4)
12
(13.5) __
155168 175! 79 175(12) 100138
1501 66 7.6 2.25(57)
_ _
Max. Sprinkler
Spacing
ft (m)
Row
Fm (Lpm)
Pressure
psi (bar)
Sprinkler
Identification
12 x 12 (3.6x3.6) 21 -
R7618
14 x 14 (4.3x4.3) 21 7.6 (0.53)
16 x 16 (4.9x4.9) 21 7.6(0.53)
18x18(5.5x5.5) 22_.._ 8.4(0,58)
20x20(6,1x6.1) 25 10.8J ),74)7 -
Note: Sprinklers shown in Fig. 3 and Fig. 4 are not
15.
Escutcheon, F2, Data:
Type Adjustment Face of Fitting
to wall Inch (mm) Inch (mm)
F2 y2 (13)
Model Fl Res 44 & 58 HSW Model Fl Res 44 & 58
Recessed HSW/F2
F2 escutcheon,
adjustr
Technical Data: Fl Res 44 HSW & HSW/F2
Nominal *Wft Max. hder
iiei OrIfice Teni Ressure MJl K Lerqh
Size Inch Fiig p TaT1 Fr kich
OF cc °F cc (mm) (bar) (mm)
1/2"NPT y'(lO) 155
175!
68
79 175(12) 100
150!
38
66 2.45(62)
Max. Sprinkler
Spacing
ft (m)
ceiling-to-
Deflector
Inch (mm)
Sprinkler Temp.
Rating
F (°C)
Row
gpm
(Lpm)
Pressure
psi (bar)
Sprinkler
klentification
Number (SIN)
12 x 12 (3.6x3.6)
4-6
(101-152)
155 (68) 175(79) 12(45.4) 7.5(0.52)
R3531
14 x 14 (4.3x4.3) 155 (68) 175(79) 14(53.0)
16 x 16 (4.9x4.9) 155 (68) 175(79) 16(60.6)
16 x 18 (4.9x5.5) 155(68) 175(79) 18(68.1)
M27.40.89)
18x 18(5.5x5.5) 155(68) 175(79) 19(72.0)
16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1)
12 x 12 (3.6x3.6)
6-12
(152-305)
155(68) 175(79) 14(53.0) 1 10.2(0.71)
27.4(1.89)
14 x 14 (4.3x4.3) 155 (68) 175 (79) 16(60.6) 13.3 (0.92)
16 x 16 (4.9x4.9) 155(68) 175(79) 17(64.4) 15.0(1.04)
16 x 18 (4.9x5.5) 155 (68) 175 (79) 20(75.7) 20.7(l.43)
16 x 20 (4.9x6.1) 155(68) 175(79) 23(87.1)
ri
Technical Data: Fl Res 58 HSW & HSWIF2
T1iad
S
Nominal
Orifice
Inch
F *Mdw Ma,c UK
[_TaTP Pnssu AITt"tJ K LaVth
PSI _
(mm) c c (bar) (mm)
y (13) 155 68 100 38 5.8 2.45(62) L1751 9 1175(12) 1501 66
Escutcheon, F2, Data:
ustment Face ofFitting I
Type to towall I Inch (mm) Inch (mm)
I F2 Y, (13)
Max Sprinkler
Spacing
ft (m)
ceili
All
ng
Deflector
Inch (mm)
Sprinkler Temp.
Rating
°F (°C)
Flow
gpm
(Lpm)
Pressure
psi (bar) p
Sprinkler
Identification
Number (SIN)
12 x 12 (3.6x3.6)
4-6
(101-152)
I
() 175 (79)
175 (79) 18(68.2)
7.6(0.53)
117L
R3533
14 x 14 (4.3x4.3)
16x16(4.9x4.9) 155(68) 175(79) 1 21(79.)j13.2(0.91)
16 x 18 (4.9x5.5) 155 (68) 175 (79) _25 (94.7) (1,28)
L 109X61JI 155(68) 175(79) 25(1.73)
I 12x12(3.6x3.6)
6-12
(152-305)
7 71
155 (68) 175 (79)
22(83,3)
22(83.3)
14.4(1.0Lj
14.4(l.0) 14 x 14 (4.3x4.3)
16 x 16 (4.9x4.9) 155 (68) 175 (79) 26(98.4) 20.1 (1.39)
I 16 x 18 (4.9x5.5) I jJ 175(79)
7.
Model Fl Res 44 SWC
r 4 to 72
1707.60mm To
I I/4 [31.75mm] Monimum 304.80mm]
Face 01 Fitting PUSH ON COVER, THEN To Wall Dimens!o TURN TO ADJUST UNTIL
TIGHT AGAINST WALL.
IX 1/2Reducer.-7
-7 Recommended
Wall Hale 2 5/16
2 5/8 (58.74mmJ.i1J_f--
166.68mm] 010. 14-1 Did. 010
V
TURN COLLAR UNI7L , TIGHT AGAINST SPRINKLER 1 2 I/32 WRENCH BOSS. [42.07mm]
I J57 I/2 (72. 70mm]
Adjusi meet
El RES 44 SWC
Fig. 5
Technical Data: Fl Res 44 SWC
itieci
Nominal
Otifice
SOW
Tarqi CouerTeni ,:
Resstie riax. K Length
Stas Inch _____ PSI
Mj3lStTgTp
Far hidi
T cc i I CF CC (mm) (bar) (mm)
1/2" NPT
(R ½)
W OO) 155 68 135 57 175(12) 100 38 4.4 2.45(62)
Max. Spunkier
(m)
Ceiling -to-
Deflector
Inch (mm)
Flow
Spacing gpm
(L4)fn)
Identification
ft
Pressure
psi (bar)
Spdnkler
Number(SIN)
12 x 12 (3.6x3.6)
4-6
(101-152)
13 (49.2) 8.7(0.60)
R3531
20.7(l.43)
14 x 14 (4.3x4.3) 14(53.0) 10.2(0.71)
16 x 16 (4.9x4.9) 17(64.3) 15.0(1.1)
16x 18(4.9x5.5) 19(71.8) 18.7(l.13)
16 x 20 (4.9x6.1) 23 (87.1) 27.4(l.89)
12 x 12 (3.6x3.6)
6-12
(152-305)
14(52.9) 10.2 (0.71)
14 x 14 (4.3x4.3) 15(56.7) 11.7(0.81)
16 x 16 (4.9x4.9) 18(68,1) 16.8(1.16)
16 x 18 (4.9x5.5) 20(75.6)
I
2. Model Fl Res 40 Recessed
HSWIF2
Escutcheon. F2. Data:
Type Adjustment Face of Fitting
to wall I Inch (mm) Inch (mm)
F2 y2 (13) X6 -%(47-174)
F2 escutcheon, /2" 11 3m
adjustment
135FG05
FACE OF FITTING TO
WALL DIMENSION I
I I/4 MIN.
(37.8mm] t -2 I/4 HOLE 0/4. 7/8 [57.2mm] [32mm] CEILING To
DEFLECTOR
x ;/2 DIMENSION
7 15/16 D/4
2 27/32 DIA.
[72.--l
TURN COLLAR
TIGHT AGAINST SPRINKLER
WRENCH ROSS.
L 7/2[13mm]
I35FG06-C AWUSTMENT
Fl RES 58. 44 & 40 HSW/F2
Fig. 7 Fig. 6
Technical Data: Fl Res 40 HSW & HSWIF2
Nominal I1dr Mw
___
Wder
flieI Orifice Tenx J iL e1 K L.engih
size Inch ig psi Teni Far Inch
CFQC cFHC (mm) (bar) (mm)
1/2"NPT /'(10) 155
175
I 68
79 175(12) 100
150
I 38
66 4.0 2.45(62)
Max. Sprinkler Ceiling Sprinkler Temp. Rori Pressure Sprinkler
Spacing Deflector Rating gpm p (bar) enhflcetion
ft (M) Inch (mm) °F(°C) (Lpm) Number (SIN)
12 x 12 (3.6x3.6)
4-6
(101-152)
155 (68) 175(79) 13(49.0) 10.6 (0.73)
R3538
14 x 14 (4.3x4.3) 155(68) 175(79) 16(60.5) 16.0(1.10)
16x16(4.9x4.9) 155 (68) ______ 17(64.3) 18.1(1.24)
16x 16(4.9x4.9) 175 (79) 18(68.1) 20.2(l.39)
16 x 18 (4.9x5.5)
_______
155 (68) 175 (79) 20(75.7) 25.0(1.72)
18 x 18 (5.5x5.5) 155(68) 175(79) 22(83.3) 30.2(2.08)
16 x 20(4.9x6.1) 155(68) 175(7p) 23 (87.0) 33.1 (2.28)
12 x 12 (3.6x3.6)
6-12
(152-305)
155(68) 175 (79)13(49.0) 10.6(0.73)
14x14(4.3x4.3) 155(68) 175 (79) 17 (64.3) 18.1 (1.24)
16 x 16 (4.9x4.9) _155L68 175 (79) 20(75.7) 25.0 (1.72)
Finithes"
Standard Finishes
Fl, F2, FP Sprinkler Escutcheons
Cover Plates
Bronze Brass White Painted
Chrome Plated Bright Chrome Plated Chrome
White Polyester White Painted
Coated
Special Application Finishes
Sprinkler Fl, F2,
Escutcheons
Cover Plates
Bright Brass Bright Brass Bright Brass
Black Plated Black Plated Black Plated
Black Paint Black Paint Black Paint
Off White Off White Off White
Satin Chrome Satin Chrome Satin Chrome
(1 Other finishes and colors are available on special order.
Consult factory for details.
Note: Paint or any other coating applied over the factory finish will
void all approvals and warranties.
Maintenance
Model Fl Res 30, 49, Fl Res 58, Fl Res 76, Fl Res 44
and Fl Res 40 Sprinklers should be inspected quarterly,
and the sprinkler system maintained in accordance with
NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with
soap and water, Ammonia or any other Cleaning fluids.
Remove dust by using a soft brush or gentle vacuuming.
Remove any sprinkler which has been painted (other than
factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick
replacement of damaged or operated sprinklers. Prior to
installation, sprinklers should remain in the original cartons
and packaging until used. This will minimize the potential
for damage to sprinklers that could cause improper
operation or non-operation.
Model Fl Res 30, 49 & 58 Pendent
Sprinkler Specifications
Sprinklers shall be [cULus Listed] [New York City MEA
Approved (258-93-E)] low flow residential pendent
sprinklers engineered to provide a minimum design
density of 0.05 gpm/ft2 over the listed coverage area.
Listed flows as specified by the manufacturer's technical
data sheets are to be used. Residential sprinklers shall be
installed in conformance with the manufacturer's
installation guidelines and the applicable installation
standard. Where pendent residential sprinklers are
installed under sloped ceilings having a pitch from [4/12] to
[8/12], the sprinklers shall be listed for such use.
Deflector-to-ceiling distance listing shall be 1" to 8"
maximum. Sprinkler frame and deflector shall be of bronze
frame construction having a ½" NPT thread. Water seal
assembly shall consist of a Teflon-coated Belleville spring
washer with top-loaded extruded or cold head cup with 3
mm glass bulb Containing no plastic parts, and having a
temperature rating of [155°F (68°C)] [175°F (790C)].
Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8.
Standard finish: [Bronze] [Chrome-plated] [White
Polyester] [Special finish- specify]. Residential pendent
sprinklers shall be Reliable Model Fl Res 30, 49 & 58, SIN
R3511, R3516&R3513 (Bulletin 135).
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Temperature Rating
Sprinkler Finish
Escutcheon Finish
Cover Plate Finish
Model Fl Res 49 & 58 Recessed Pendent/F1,
Model Fl Res 30,49 & 58 Recessed PendentlF2,
Model Fl Res 30,49 & 58 Recessed Pendent/FP
Sprinklers shall be [cULus Listed] [New York City MEA
Approved (258-93-E)] low flow residential recessed
pendent sprinklers engine9red to provide a minimum
design density of 0.05 gpm/ft over the listed coverage area.
Listed flows as specified by the manufacturer's technical
data sheets are to be used. Residential sprinklers shall be
installed in conformance with the manufacturer's installation
guidelines and the applicable installation standard. Where
pendent residential sprinklers are installed under sloped
ceilings having a pitch from [4/12] to [8/12], the sprinklers
shall be listed for such use. Deflector-to-ceiling distance
listing shall be 1" to 8" maximum. Sprinkler frame and
deflector shall be of bronze frame construction having a ½"
NPT thread. Water seal assembly shall consist of a
Teflon-coated Belleville spring washer with top-loaded
extruded or cold head cup with 3 mm glass bulb containing
no plastic parts, and having a temperature rating of [155°F
(68°C)] [175°F (790C)]. Sprinklers shall have a nominal
K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze]
[Chrome-plated] [White Polyester] [Special finish- specify].
Recessed escutcheon assembly shall be a steel, two-piece
escutcheon [with ½" adjustment (Model F2)] [with 3/4"
adjustment (Model Fl)] [of push-on and thread off design
with ½" adjustment (Model FP)]. Standard finish shall be
[brass][bright chrome] [white painted]. Residential
recessed pendent sprinklers shall be Reliable [Model Fl
Res 3.0, 49 & 58 Recessed PendentJFl] [Model Fl Res 30,
49 & 58 Recessed Pendent/F2] [Model El Res 30, 49 & 58
Recessed PendentJFP] SIN R35.1 1, R3516 & R3513
(Bulletin 135).
10.
Model Fl Res 30,49 & 58 CCP Pendent (Concealed)
Sprinklers shall be [cULus Listed] [New York City MEA
Approved (258-93-E)] low flow residential concealed
sprinklers engineered to provide a minimum design
density of 0.05 gpm/ft2 over the listed coverage area.
Listed flows as specified by the manufacturer's technical
data sheets are to be used. Residential sprinklers shall
be installed in conformance with the manufacturer's
installation guidelines and the applicable installation
standard. Where pendent residential sprinklers are
installed under sloped ceilings having a pitch from [4/12]
to [8/12], the sprinklers shall be listed for such use.
Sprinkler frame and deflector shall be of bronze frame
construction having a 1/2" NPT thread. Water seal
assembly shall consist of a Teflon-coated Belleville
spring washer with top-loaded extruded or cold head
cup with 3 mm glass bulb containing no plastic parts, and
having a temperature rating of 155°F (680C). Cover plate
assembly shall consist of a brass cover plate and copper
alloy retainer flange. Method of attaching the cover plate
to the sprinkler cup shall be a push-on and thread-off
design allowing a ½" cover plate adjustment. Cover
plate temperature rating shall be 135°F (57°C). A plastic
protective cap shall be provided and factory installed
inside the sprinkler cup to protect the sprinkler from
damage, which could occur during construction before
the cover plate is installed. Standard cover plate finish:
[White] [Custom Color- specify]. ]. Concealed pendent
sprinklers shall be Reliable Model Fl Res 30, 49 & 58
COP, SIN R3511, R3516 & R3513 (Bulletin 135).
Model Fl RES 40 and Fl Res 44 Horizontal Sidewall
Residential Sprinkler Specifications
Model Fl Res 40 Horizontal Sidewall Sprinkler
Sprinklers shall be [cULus Listed] [New York City MEA
Approved (258-93-E)] low flow residential horizontal
sidewall sprinklers engineer! to provide a minimum
design density of 0.05 gpm/ft over the listed coverage
area. Listed flows as specified by the manufacturer's
technical data sheets are to be used. Residential
sprinklers shall be installed in conformance with the
manufacturer's installation guidelines and the applicable
installation standard. Where horizontal sidewall
residential sprinklers are installed under sloped ceilings
having a pitch from [4/12] to [8/12], the sprinklers shall be
listed for such use. Sprinkler frame and deflector shall be
of bronze frame construction having a ½" NPT thread.
Water seal assembly shall consist of a Teflon-coated
Belleville spring washer with top-loaded extruded or cold
head cup with 3 mm glass bulb containing no plastic
parts, and having a temperature rating of [155°F (680C)]
[175°F (790C)]. Sprinklers shall have a nominal K-factor of
4.0 (57.1). Standard finish: [Bronze] [Chrome-plated]
[White Polyester] [Special finish- specify]. Residential
horizontal sidewall sprinklers shall be Reliable Model Fl
Res 40, SIN R3538 (Bulletin 135).
Model Fl Res 40 Recessed
Horizontal Sidewall Sprinkler
Use description for the Model Fl Res 40 horizontal
sidewall sprinkler with the following modifications: Replace
"horizontal sidewall sprinkler" with 'recessed horizontal
sprinkler." Add: Recessed escutcheon assembly shall be
a steel, two-piece escutcheon with ½" adjustment (Model
F2). Standard finish shall be [brass][bright chrome] [white
painted] [Special finish- specify]. Residential recessed
horizontal sidewall sprinklers shall be Reliable Model Fl
Res 40/F2, SIN R3538 (Bulletin 135).
Model Fl Res 44 Horizontal Sidewall Sprinkler
Sprinklers shall be [cULus Listed] [New York City MEA
Approved (258-93-E)] low flow residential horizontal
sidewall sprinklers engineered to provide a minimum
design density of 0.05 gpmlft2 over the listed coverage
area. Listed flows as specified by the manufacturer's
technical data sheets are to be used. Residential
sprinklers shall be installed in conformance with the
manufacturer's installation guidelines and the
applicable installation standard. Where horizontal
sidewall residential sprinklers are installed under sloped
ceilings having a pitch from [4/12] to [8/12], the
sprinklers shall be listed for such use. Sprinkler frame
and deflector shall be of bronze frame construction
having a ½" NPT thread. Water seal assembly shall
consist of a Teflon-coated Belleville spring washer with
top-loaded extruded or cold head cup with 3 mm glass
bulb containing no plastic parts, and having a
temperature rating of [155°F (6811C)] [175°F (790C)].
Sprinklers shall have a nominal K-factor of 4.4 (62.8).
Standard finish: [Bronze] [Chrome-plated] [White
Polyester] [Special finish- specify]. Residential
horizontal sidewall sprinklers shall be Reliable Model Fl
Res 44, SIN R3531 (Bulletin 135).
Model Fl Res 44 Recessed
Horizontal Sidewall Sprinkler
Use description for the Model Fl Res 44 horizontal
sidewall sprinkler with the following modifications:
Replace "horizontal sidewall sprinkler" with "recessed
horizontal sprinkler." Add: Recessed escutcheon
assembly shall be a steel, two-piece escutcheon with ½"
adjustment (Model F2). Standard finish shall be
[brass][bright chrome] [white painted] [Special finish-
specify]. Residential recessed horizontal sidewall
sprinklers shall be Reliable Model Fl Res 44/F2, SIN
R3531 (Bulletin 135).
ii,
Model Fl Res 76 Pendent
prinklers shall be [cULus Listed] low flow residential
pendent sprinklers engineere to provide a minimum
design density of 0.05 gpmlft over the listed coverage
area. Listed flows as specified by the manufacturers
technical data sheets are to be used. Residential
sprinklers shall be installed in conformance with the
manufacturer's installation guidelines and the applicable
installation standard. Sprinkler frame and deflector shall be
of bronze frame construction having a 3/4" NPT thread.
Water seal assembly shall consist of a Teflon-coated
Belleville spring washer with machined or cold head cup
with 3 mm glass bulb containing no plastic parts, and
having a temperature rating of [155°F (680C)] [175°F
(790C)]. Sprinklers shall have a nominal K-factor of 7.6.
Standard finish: [Bronze] [Chrome-plated] [White
Polyester] [Special finish- specify]. Residential pendent
sprinklers shall be Reliable Model Fl Res 76, SIN R7618
(Bulletin 135).
Model Fl Res 76 Recessed Pendent/F1,
Model Fl Res 76 Recessed Pendent/F2,
Model Fl Res 76 Recessed Pendent/FP
Sprinklers shall be [cULus Listed] low flow residential
recessed pendent sprinklers engineer 9d to provide a
minimum design density of 0.05 gpm/ft over the listed
coverage area. Listed flows as specified by the
manufacturer's technical data sheets are to be used.
Residential sprinklers shall be installed in conformance
with the manufacturer's installation guidelines and the
applicable installation standard. Sprinkler frame and
deflector shall be of bronze frame construction having a
3%" NPT thread. Water seal assembly shall consist of a
Teflon-coated Belleville spring washer with machined or
cold head cup with 3 mm glass bulb containing no
plastic parts, and having a temperature rating of [155°F
(68°C)] [175°F (790C)]. Sprinklers shall have a nominal
K-factor of 7.6. Standard finish: [Bronze]
[Chrome-plated] [White Polyester] [Special finish-
specify]. Recessed escutcheon assembly shall be a
steel, two-piece escutcheon [with ½" adjustment (Model
F2)] [with 3/4" adjustment (Model Fl)] [of push-on and
thread off design with ½" adjustment (Model FP)].
Standard finish shall be [brass][bright chrome] [white
painted]. Residential recessed pendent sprinklers shall
be Reliable [Model Fl Res 76 Recessed Pendent/Fl]
[Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res
76 Recessed Pendent/FP] SIN R7618 (Bulletin 135).
Model Fl Res 76 CCP Pendent (Concealed)
Sprinklers shall be [cULus Listed] low flow residential
concealed sprinklers engineered to provide a minimum
design density of 0.05 gpm/ft2 over the listed coverage
area. Listed flows as specified by the manufacturer's
technical data sheets are to be used. Residential sprinklers
shall be installed in conformance with the manufacturer's
installation guidelines and the applicable installation
standard. Sprinkler frame and deflector shall be of bronze
frame construction having a 3/4" NPT thread. Water seal
assembly shall consist of a Teflon-coated Belleville spring
washer with machined or cold head cup with 3 mm glass
bulb containing no plastic parts, and having a temperature
rating of 155°F (680C). Cover plate assembly shall consist
of a brass cover plate and copper alloy retainer flange.
Method of attaching the cover plate to the sprinkler cup
shall be a push-on and thread-off design allowing a ½"
cover plate adjustment. Cover plate temperature rating
shall be 135°F (570C). A plastic protective cap shall be
provided and factory installed inside the sprinkler cup to
protect the sprinkler from damage, which could occur
during construction before the cover plate is installed.
Standard cover plate finish: [White] [Custom Color-
specify]. ]. Concealed pendent sprinklers shall be Reliable
Model Fl Res 76 CCP, SIN R7618 (Bulletin 135).
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research
Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable.
Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable
sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices Z% Recycled
(800) 848-6051 Sales Fax %l Paper
(914) 829-2042 Corporate Offices Revision tines indicate updated or new data.
ww.reliablesprinkler.ccm Internet Address EG. Printed in U.S.A. 06/08 P/N 9999970235
Vertical Sidewall Conventional
Upright
it
Pendent
Horizontal Sidewall Recessed Pendent
Extended Coverage Recessed Extended
Pendent Coverage Pendent
At normal temperatures, the glass bulb contains the
fluid in both the liquid phase and in the vapor phase.
The vapor phase can be seen as a small bubble. As
heat is applied, the liquid expands forcing the bubble
smaller and smaller as the liquid pressure increases.
Continued heating forces the liquid to push out against
the bulb, causing the glass to shatter, opening the
waterway and allowing the deflector to distribute the
discharging water.
The Fl Sprinkler temperature rating is identified by
the color of the glass bulb capsule as well as frame
color where applicable.
Bulletin 117 Rev.T
Model Fl
I
®Model Fl Recessed
Standard Response
Sprinklers
The Designer® Model Fl Sprinkler
Standard Upright
Standard Pendent
Extended Coverage Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
- HSW1 Deflector
The Designer®Il Model Fl Recessed Sprinkler
Recessed Pendent
Recessed Extended Coverage Pendent
Approval Organizations
Underwriters Laboratories Inc.
Underwriters' Laboratories of Canada
Factory Mutual Research Corp.
Loss Prevention Council
NYC BS&A No. 587-75-SA
Pleniere Assemblee
Verband der Schadenversicherer
NYC MEA 258-93-E
UL Listing Category
Sprinklers, Automatic & Open (VNIV)
Patents: U.S. Patent No. 6,374,92
Applies to Model Fl Vertical Sidewall Sprinklers.
Product Description
The Fl Glass Bulb Sprinkler combines the durability
of a standard sprinkler with the attractive low profile of
a decorative sprinkler. Whether installed on exposed
piping or in an office ceiling, it is functional and
attractive. The Horizontal and Vertical Sidewall
Sprinklers provide an equally attractive appearance
when ceiling piping cannot be used.
Beautifully versatile is the description for the Reliable
Model Fl Recessed Designer glass bulb sprinkler.
Recessing The Designer® enhances its already low
profile decorative appearance, and facilitates a rapid
and perfect installation.
Model El Recessed Designer's escutcheon is highly
adjustable. The two piece construction makes field
installation a very easy and rapid task. This also allows
ceiling panels to later be removed without shutting
down the fire protection system, thus facilitating
maintenance of above ceiling services.
The Designer® Automatic Sprinkler utilizes a frangible
glass bulb. The glass bulb consists of an accurately
controlled amount of special fluid hermetically sealed
inside of a precisely manufactured glass capsule. This
glass bulb is specially constructed to provide fast
thermal response.
The Reliable Automatic Sorinkler Co.. Inc.. 103 Fairview Park Drive. Elmsford. New York. 10523
Model Fl Upright, Pendent & Conventional Sprinklers
* Installation Wrench: Model D Sprinkler Wrench
Upright Pendent Conventional
Installation Data:
Nominal Nominal K Factor
________________ Sprinkler Approval Sprinkler Identification Numbers
(SIN) Orifice Thread Size Height Organization I US I Metric _____ Upright I Pendent
Standard-upright (SSU) and pendent Deflectors Marked to Indicate Position
(15mm)
'/' NPT
(R1/2) 5.6 80 2.2'
(56mm) 1,2,3,4,5,6,7 R17254 81715
17/32'
(20mm)
3/4' NPT
(A3/4) 8.0 115 2.3'
(58mm)
1,2,3,4,7,8 R1722 81712
½' ½' NPT
5.6 80
2.2'
(15mm)3 (81/2) (56mm)
17/32'
(20mm)°
3%' NPT
(83/4)
8.0 115 2.3'
(58mm) 7
7/16'
(11mm)
½' NPT
(81/2) 4.2 60
2.2' 1,2,8 (56mm)
R17234 81713
3/8'
(10mm)
½' NPT
(R1/2)
2.8
___________
40 2.54'
(65mm) 1,2,8 R1721 81711
10mm XLH R3/8 4.2 i 60 56.1mm 4,6,7 R1724 81714
Conventional-Install in Upright or Pendent Position
10mm XLH 83/8 { 4.2 1 60 56.1mm -------- 81774
15mm 1/2' NPT
{
I 5.6 80 56.1 mm (R1/2) 4,6,7 R1775
20mm 3%'NPT
(R3/4) [ 8.0 115 58.1mm 4,7 R1772
LPC Approval up to 286°F (141°C)
FM Approval for SSU up to and including 200°F (93°C) only.
(F1S5) VdS Approval for Intermediate Response 155°F (68°C) only.
Polycoated upright UL and ULC listed corrosion resistant.
2.
TURN COLLAR
UNTIL TIGHT
AGAINST SPRINKLER
WRENCH BOSS
r7 7 7'77
3/4 ADJUSTMENT hecessec I-'enaent
-2 7/4' HOLE 014.
[57 2_1 572mm]
H- 7 15/76' 0/A.
[4 9.2mm]
Xi/2REDUCER
I (
I
/5/76'
[3.2mm] 7 [25.4mm]
Màdel Fl Recessed Pendent Sprinkler
Installation Wrench: Model GFR1 Sprinkler Wrench
I
755F001A
II 7PGOIA I- 2 27/32" 0/A.
[72.2mm]
(1) When installed directly into a tee, the escutcheon dimensions
adjustment will be reduced.
Installation Data:
Nominal I Thread Size
Nominal K Factor Sprinkler Height Approval Sprinkler Identification
US Metric Orifice Organization Numbers (SIN)
/2'
(15mm)
½' NPT
(R1/2)
5.6 80 2.2'
(5 1,2,3,4.5,7 R17156mm)
17/32
(20mm)
3%'NPT
(R3/4) 8.0 115 2.3'
(58mm) 1,2,3,4,8 R1712
½'
(15mm)4
WNPT
(R1/2) 5.6 80
2.2'
(56mm)
17/32'
(20mm)4
3%' NPT
(R3/4)
8.0 115 2.3'
(58mm) 7
7/16'
(11mm)
1/2' NPT
(R1/2) 4.2 60 2.2'
(56mm)
1,2,8 R1713
3/8' ½' NPT 2.8 40 2.2" 1,2,8 R1711
(10mm) (R1/2) (56mm)
10mm R3/8 4.2 60 56.1 MM 4,7 R1714
(2) FM Approval
Light Hazard - No Limitations
Ordinary Hazard - Groups 1 & 2, Wet Systems only.
LPC Approval is for 57°C through 93°C ratings.
VdS Approval for Intermediate Response 155F (68°C) only.
3.
vertical biaewaii
Nodël Fl Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
U.S. Patent No. 6,374,920
Sprinkler Type Deflector to Ceiling Distance
(Mm.. Max.)
Upright 4 (102mm) - 12 (305mm) I
Pendent 4 (102mm) - 12 (305mm)
Installation Data:
Nominal Orifice Thread Size
Nominal Factor Sprinkler
I Height Organizations
Approval Identification
Sprinkler I
I I Numbers (SIN) I j US I Metric
W (15mm) W NPT (R1/2) 5.6 8.0 2.2 (56.1mm) 1,2,3,4,6,8 R1785
(1) LPC Approval is pendent only, 57°C through 141°C ratings.
Model Fl Horizontal Sidewall Sprinkler
Deflector: HSW 1
Installation Wrench: Model D Sprinkler Wrench
7'., ~ M-o*
Horizontal Sidewall
90,10,01, 1
3/l6-5/l5----
[5,-24,,] I I/4 MIN.
-2 7/4 HOLE 01.4. I-I/8 [70I.6mn- I52.4v,,]
CEILING TO
Ixi/2REDUCER
7L
DEFLECTOR
2
TI/RN COLLAR UNTIL '
TIGHT AGAINST SPRINKLER WRENCH BOSS.
3/4 H ADJUSTMENT
Installation Data:
J Nominal
Orifice Thread Size i
Nominal K Factor Sprinkler
I
Height
Approval Organizations Sprinkler
I identification
Numbers (SIN) US
I
Metric Light Hazard Ordinary
Hazard
W(l5mm) WNPT
(R1/2) 5.6 80 2.63(67mm) 1,2,3,5 1,2,5 R1735
Note: UL and ULC Listing permits use with Fl escutcheons, light hazard only.
4
Extended Coverage Pendent
Extended Coverage
Recessed
Model Fl Extended Coverage Pendent Sprinkler
Deflector: EC Pendent
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Extended Coverage - Light Hazard Occupancy
Coverage Area
Pressure
Flow Rate Max. Area Width x Length Nominal
K=8.0 (115) K=5.6_(80)
gpm L/min psi bar psi bar ft. x ft m x m
26 98.4 10.6 0,7 21.6 I 1,5 16x 16 I 4.9x4.9
33 125.0 17.0 I 1,2 34.7 I 2,4 18 x 18 5.5 x 5.5 40 151.4 25,0 1,7 51.0 3,5 20 x 20 6.0 x 6.0
/
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Temperature Rating Sprinkler
US Metric °C Orifice Size Height Organizations Identification
Numbers (SIN)
17/32'
(20mm)
34NPT
(83/4) 8.0 115 2.2(56mm) 1,2,8 135,155 57,68 R1742
½' (15mm) 1/2 NPT
(R1/2) I 5.6 80 2.2 (56mm) 1,2,8 135,155 57,68 R1745
-2 ,/ ,HOLE 0I4—
/4J —1
23/C REDUCER
(24 DIll 3
IVUN COLLAR ,.- OR - 2 : I /2 REDUCER UNTIL DENT / [2541,,, 2 I27In3 IGRUIST SPRINVIER .REICH ROSS
3/4IDJUSDIENT_J TLi
p''
I17rW,A 2 27/32 02.
[722-1
(1) When installed directly into a tee, the escutcheon
dimension's adjustment will be reduced.
Coverage Area
Pressure
Flow Rate Width x Length
MaL Areaow Nominal
(=8.0(115) K=5.6 (80)
gpm L/min psi bar psi I bar ft. x ft. m x m
26 984 10.6 I 0,7 21.6 1,5 16 x 16 4.9 x 4.9
33 I 125.0 17.0 I 1,2 34.7 2,4 18 x 18 I 5.5 x 5.5
40 151.4 25,0 j 1,7 j 51.0 I 3,5 20 x 20 6.0 x 6.0
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Temperature Rating Sprinkler
US Metric °F °C Orifice Size Height Organizations Identification
Numbers (SIN)
17/32'
(20mm)
3%'NPT
(R3/4) 8.0 115 2.2W (56mm) 1,2,8 135,155 57,68 R1742
1/2 (15mm) ½' NPT
(R1/2) 5.6 80 2.2' (56mm) 1,2,8 135, 155 57,68 R1745
F).
Model Fl Recessed Extended Coverage Pendent Sprinkler
Deflector: EC Pendent
Installation Wrench: Model GFR1 Sprinkler Wrench
Approval Type: Extended Coverage - Light Hazard Occupancy
iLodej1171 & Fl Recessed Sprinklers
plication
Model Fl and Fl Recessed sprinklers are used in
fixed fire protection systems: Wet, Dry, Deluge or
Preaction. Care must exercised that the orifice size,
temperature rating, deflector style and sprinkler type
are in accordance with the latest published standards
of the National Fire Protection Association or the
approving Authority Having Jurisdiction.
Installation
Model El sprinklers are standard response sprinklers
intended for installation as specified in NFPA 13. They
must also be installed with the Model D Sprinkler
Wrench specifically designed by Reliable for use with
these sprinklers.
The Model Fl Recessed Sprinklers are to be installed
with a maximum recess of 3/4 inch (19mm). The Model
Fl Escutcheon illustrated is the only recessed
escutcheon to be used with the Model Fl Pendent and
EC Sprinklers. The use of any other recessed
escutcheon will void all approvals and negate all
warranties. When installing Model Fl Recessed
Pendent and EC Pendent Sprinklers, use the Model
GFR1 Sprinkler Wrench. Any other type of wrench may
damage these sprinklers.
Glass bulb sprinklers have orange covers to protect
the bulb during the installation process. REMOVE THIS
PROTECTION ONLY AFTER THE SYSTEM HAS BEEN
HYDROSTATICALLY TESTED AND, WHEN APPLICABLE,
THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO
wrenches are designed to install sprinklers when
covers are in place.
Maintenance
The Models El and El Recessed Sprinklers should
be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean
sprinklers with soap and water, ammonia or any other
cleaning fluid. Remove any sprinkler which has been
painted (other than factory applied) or damaged in any
way. A stock of spare sprinklers should be maintained
to allow quick replacement of damaged or operated
sprinklers. Prior to installation, sprinklers should be
maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non-operation.
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Deflector Type
Temperature Rating
Sprinkler Finish
Escutcheon Finish (where applicable)
Temperature Ratings
Classification
Sprinkler
Temperature
Maximum
Ambient
Temperature Bulb Color
°F °C
Ordinary 135 57 100 38 Orange
Ordinary 155 68 100 38 Red
Intermediate 175 79 150 66 Yellow
Intermediate 200 93 150 66 Green Hight 286 141 225 107 Blue
Extra Hight 360 182 1 300 1 149 1 Mauve
(1) Not Available for Fl Recessed
Patents: U.S. Patent No. 6,374,920
Applies to Model Fl Vertical Sidewall Sprinklers.
Finishes"
Standard Finishes
Sprinkler Escutcheon
Bronze Brass
Chrome Chrome
White Polyester Coated (3)(6) White Painted
Special Application Finishes
Sprinkler Escutcheon
Bright Brass(2)Bright Brass
Black Plated Black Plated
Black Paintt34 Black Paint
Off White (3) Off White
Satin Chrome Satin Chrome
Lead Plated(3X4)
Wax Coated (3)(4)(5)
Wax _Over _Lead t3 t4t
Other colors and finishes are available on special order. consult
factory for details.
200°F (93°C) maximum.
UL and ULC listed, and NYC approved only.
155°F to 200°F (68°C to 93°c) ratings only.
286°F (141°c) sprinklers may be coated for ambient conditions not
exceeding 150°F (66°C).
UL and ULC listed corrosion resistant SIN numbers: R1721, R1722,
R1723 and R1725.
Note: For ½" orifice pendent FM approved white
polyester coated and UL approved white polyester
corrosion resistant sprinklers refer to Bulletin 013.
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,
Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever
applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most
highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc. ® (800) 431-1588 Sales Offices HIM, iable (914) 829-2042 Corporate Offices
(800) 848-6051 Sales Fax
www.reliablesorinkler.com Internet Address
Recycled Paper
Revision lines indicate updated or new data
E.G. Printed in U.S.A. 11/08 P/N 9999970011
B_________ A
G
SPECFCATON S1 JBMtTTAL SHEET
f.:
.--
-) ' .)
?-11 )çML r
U" • '.
\,. 6
FEATURES
Sizes: 03/4" U 1" U 1-1/4 U 1-1/2" U 2"
Maximum working water pressure 175 PSI
Maximum working water temperature 180°F
Hydrostatic test pressure 350 PSI
End connections Threaded ANSI B1.20.1
OPTIONS
(Suffixes can be combined)
U - with full port QT ball valves (standard)
U L - less ball valves
U U - with union ball valves
U S - with bronze "Y" type strainer
U TCU - with test cocks "vertical" up
U V - with union swivel elbows (3/4" & 1")
U OSY - with OS & Y gate valves
U FDC - with fire hydrant connection (2" only)
U FT - with integral male 450 flare SAE test fitting
APPLICATION
Designed for installation on potable water lines to protect
against both backsiphonage and backpressure of polluted
water into the potable water supply. Assembly shall provide
protection where a potential health hazard does not exist.
STANDARDS COMPLIANCE
(All sizes approved horizontal. Vertical approvals as
listed below.)
ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2")
IAPMO® Listed (vertical 11/4-2")
CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2")
AWWA Compliant C510 (vertical 3/4")
UL® Classified (less shut-off valves only)
C-UL® Classified (less shut-off valves only)
Approved by the Foundation for Cross Connection
Control and Hydraulic Research at the University of
Southern California (vertical 3/4")
City of Los Angeles Approved (vertical 1-1/4"-2")
NYC MEA 426-89-M VOL 3
MATERIALS
Main valve body Cast Bronze ASTM B 584
Access covers Cast Bronze ASTM B 584
Internals Stainless Steel, 300 Series
Elastomers Silicone (FDA approved)
Buna Nitrile (FDA approved)
Polymers NoryllM, NSF Listed
Springs Stainless steel, 300 series
ACCESSORIES
U Repair kit (rubber only)
U Thermal expansion tank (Model WXTP)
U QT-SET Quick Test Fitting Set
U Test Cock Lock (Model TCL24)
IC
DIMENSIONS & WEIGHTS (do not include pkg.)
DIMENSIONS (a proximate) WEIGHT
MODEL A UNION LESS WITH
SIZE A BALL B LESS BALL c 0 E F G BALL BALL
VALVES VALVES VALVES VALVES
mm in. mm in. mm in. I mm in. Imm in. mm in. mm in. mm in. Imm lbs I kg ths
3/4 20 111/4 2861 121/2 318 1 7 178 11/2 38 3 176 31/2 89 1 3 76 15 1381 5 2.3 7 3.2
1 25 121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6112 5.4
11/4 32 151/2419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546 16 7.3 22 10
1 1/2 40 171/8 435 19 1/8 486 109/16 268 2 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10
2 50 181/4460 20 508 109/16 268 2 51 3 1/2 89 41/2 114 41/2 114 251/8 638 16 7.3 28 12.7
Page 1 of 2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5786
L. '4 Ii I A&JHWF-ft 14 P I .41 I 1 04 Ml1 P AAIM P iAk
w
U) 16
0.
p
FLOW CHARACTERISTICS
MODEL 950XL 3I4, 1", 1 114",11 1/2" & 2" (STANDARD & METRIC)
FLOW RATES (us)
2.52 3.8 5.0
I I 20 m 4(2 >/'i
40 60 80
1.26
OL
0
103
y.;
(I)
69
35
50 100 150 200 250 "-
FLOW RATES (GPM)
0 Rated Flow (Established by approval agencies)
TYPICAL INSTALLATION
Local codes shall govern installation requirements. To be
installed in accordancewith the manufacturer's instructions
and the latestedition of the Uniform Plumbing Code. Unless
otherwise specified, the assembly shall be mounted at a
minimum of 12" (305mm) and a maximum of 30" (762mm)
above adequate drains with sufficient side clearance for
testing and maintenance. The installation shall be made
so that no part of the unit can be submerged.
OUTDOOR INSTALLATION
Capacity thru Schedule 40 Pipe
Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec
1/8" 1 1 2 3
1/4" 2 2 3 5
3 4 6 9
1/2 5 7 9 14
fl-r 0 1`1)1 IL. 4I7 I
1" 13 20 27 40
1 1/41 23 35 47 70
1 lIZ 48 bi
2' 52 78 105 167
DIRECTION OF FLOW
INDOOR INSTALLATION
SPECIFICATIONS
The Double Check Valve Back-flow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball
valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall
be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be acces-
,..,i..I,., c,.. ..--, • ,;ei,,... •e el.,,.. ;....-- ei. line. Tl. r ,i.j Check ' 0 Shall maintenance II,C without removing l the UCVII.,C II UI II LI IC nrIC. I I IC IJOuL,Ie '.iI Ie¼fl VQIVC L.)0'.,I\lIIjY I rove ILCI e
a WILKINS Model 950XL.
WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766
IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292
Product Support Help Line: 1-877-BACKFLOW(1-877-222-5356) • Website: http://www.zurn.com