Loading...
HomeMy WebLinkAbout2775 OCEAN ST; ; FA090041; PermitCity of Carlsbad Fire Alarm Permit II.iiI!IsIiI Job Address: 2775 OCEAN ST Permit Type: FALARM Parcel No: 2032350200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 7/20/2009 Approved: Issued: Inspector: Project Title: BEACH TERRACE INN TWO FIRE ALARM INSPECTIONS @ $65/EA Owner: TOBO INVESTMENTS Applicant: CROSSWAY FIRE PROTECTION SUITE 302 2801 CAMINO DEL RIO SO SAN DIEGO, CA 619-702-3473 2785 ROOSEVELT ST CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 Parsley Consulting FILE COPY 350 Wt 9th Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 Fax(760) 745-0537 July 17, 2009 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Beach Terrace Inn Alarm System, East & West Buildings, 2775 Ocean Street, Carlsbad, California Dear Mr Weigand: We have reviewed the submittal as prepared by Crossway Fire Protection. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. Sincerely, PA EYCONSULTJNG i enneth W. agone9ET Office Manager End (1) Working Drawings - 2 sets Product Submittals - 1 set Review Comments - 1 set Note: A copy of this letter has been transmitted via fax to Crossway Fire Protection on July 17, 2009 FILE COPY fi1e:\S:\REV1EWS\Rev2092360.001wpd Beach Terrace Inn Alarm System Review Comments. Page 2 Review Comments Beach Terrace Inn Alarm System, 2775 Ocean Street, Carlsbad, California 1. Per the provisions of the California Fire Code, section 907.10.1.3 at least two sleeping units in each building must be provided with audible/visual notification devices. Based on the battery calculation totals for the 24FS6/8 power supply this should not create a current draw in excess of the capacity of the batteries provided. These devices should be field verified to be in place. 2. The horn/strobe devices in the laundry and housekeeping rooms in the East building on level 1, did not have a candela rating specified. Based on the current shown in the battery calculations these devices should be 15 cd rated, with the audible setting at non-temporal high. This can be field verified. 3. The following errors on the 24F56/8 battery calculations have been blueline corrected on the drawing: Circuit titles were in error. Alarm current for standby power supply not shown on plans. Decimal error in total alarm current. Catalog data sheet for 24FS6/8 requires two 12V 7.0aH batteries to be installed as a minimum. The aH rating of the batteries on the plan has been corrected. 4. No provision was found to monitor fire sprinkler system tamper and water flow switches. We do not have data on whether or not this building is being protected by automatic sprinklers, however it would seem to be required for this type of occupancy. Field verify that if such devices are present that they are incorporated into the fire alarm system panel. 5. We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off' test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the system should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. Ao oo4( PILE Copy Letter of Transmittal FROM: Cross Way Fire Protection 2801 Camino del Rio So. Ste. 302 San Diego, Ca. 92108 California license #558046 Cl 0,C1 6 www.CrossWayFire.com (619) 702.3473 phone (619) 702.3474 fax email: service@crosswayfire.com L-1 Carlsbad Fire Dept. 2560 Orion Way Carlsbad, CA 92010 (760) 931-2141 Project Beach Terrace Inn 2775 Ocean St Carlsbad, CA 92008 (760) 729-5951 compItan le with the current appc ç%ie and %Landard tn fore in the Theiwfl otcofltraCt0r may uttltiC this ievIW in uIWofl of an aptCatt0t0r a building perlflit with the 1CSS that this review no way relicYes the onj contractor or their engineer or anhiLe' 11w, ote wsIhIIttY for full cott1PIia with aid codes and sta*Ia(d'. tnctudtt the hut%dlfl0 or br any rtpon'thtt(Y for defictC'. error dthisii0t$ or ngI'ge" tu the.e pIaft whcthCr or not totd' tMc. review. Date, 7 / 7 flevtCweT 0 RECOMME AI)PRVAL Rb-Ct )M ME NI) At PRO .. AS NOTED D60 / - , Regarding above listed project. TMENT .. - D\J'ED Enclosed are plans and specs for new fire alarm system.2_r on and . . required idt1ons in Bob Akins . with Fax: 619 702.3473 - 3r,,)inq 'i dtvj permit J g-1 FILE COPY FireuTe iarms by Honeywell MS-9200UDLS Rev.2 Battery Calculation Secondary Power Source Requirements Standby Current (amps) 1 Secondary Alarm Current (amps) Device 12FType Main Circuit Board 1 x 0.137000 = 0.137000 _____T_ x 0360000 = 0.360000 XRM-248 0 x 0.000000 = 0 x 0.000000 = 4XTMF 0 x 0.005000 0 x 0.011000 = IPDACT 0 x 0.100000 0 x 0.300000 IPDACT-2/2UD 0 x 0.0Q8000 = 0 x 0.155000 ANN-BUS Devices ANN-80(-W) 1 x 0.015000 0.015000 1 x 0.040000 0.040000 ANN-LED 0 x 0.028000 0 xj 0.068000 = ANN-RLED 0 x 0.028000 = 0 x 0.068000 ANN-RLY 0 x 0.015000 0 x 0.075000 ANN-I/O 0 x 0.035000 = 0 x 0.200000 = ANN-S/PG 0 x 0.045000 = 0 x 0.045000 = ACS Annunciators ACM-8RF 0 x 0.030000 0 XI 0.158900 1 ACM-16ATF 0 x 0.040000 0 x 0.056000 ACM-32AF 0 x 0.040000 = 0 x 0.056000 = AEM-16ATF 0 x 0.002000 0 x 0.018000 AEM-32AF 0 x 0.002000 = 0 x 0.018000 = AFM-I6ATF 0 x 0,040000 0 x 0.056000 = AFM-32AF 0 x 0.040000 = 0 x 0.056000 = AFM-I6AF 0 x 0.065000 = LDM-32F = 0 0.040000 = x 0.056000 ____________ LDM-E32F 0 0 JXO.025000 0.002000 x 0.018000 ____________ LCD-80F 0 0 0.025000 = esettabIe Power ____________ 4-Wire Smoke Detectors 0 x[ 0.000000 = 0 lx! 0.000000 !1 Addressable Devices BEAtv1355 0 x 0.002000 = I=f BEAM355S 0 x 0.002000 = BEAM1224 0 x 0.017000 = CP355 0 x 0.000300 5D355 0 x 0.000300 SD3551 0 x 0.000300 AD355 0 x 0.000300 = H355 0 x 0.000300 H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = U350RP 0 x 0.000300 = D350PL 0 xj 0.000300 L)350lPL 0 xj 0.000300 = F-300 0 xj 0.000400 F-300-10 0 x 0.003500 F-300 Th" x 0.000750 F-301 0 x 0.000375 = F-302 0 x 0.000270 = F-302-6 0 x 0.002000 = -I2LX 0 x 0.000230 = C F-300 x 0.000390 C F-300-6 0 x 0.002250 RF-300 0 x 0.000270 = CRF-300-6 0 x 0.001450 0 0 x 0.000400 = B501BH-2 0 x 1 0.001000 = B501 BHT-2 0x 0.001000 24RB 0 x 0.000500 = 24B1 0 0.000450 Maximum alarm draw for all Addressable devices ----------->1 0.400000 EOLR-1 3 IxI 0.020000 1 =1 0.060000 1 3 jxj 0.020000 1 =1 0.060000 Power Supply 5495 1 1 jxj 0.075000 1 = 1 0.075000 1 1 IxI 0.175000 1 =1 0.175000 Fire-Lite Alarms Page 1 7/1012009 Pull Station BG-12LX 18 x 0.000300 0.005400 18 x 0.000000 = 0.000000 Smoke Detector SD355 40 x 0.00000 = 0.012000 40 x 0.006500 = 0.260000 Heat Detector H0355 4 x 0.000300 = 0.001200 4 x 0.006500 = 0.026000 0 x 0.000000 = 0 x 0.000000 = NAC1 I x 0.171000 = 0.171000 NAC 2 1 Ix, 0.267000 0.267000 NAC3 1 IxI 0.262000 = 0.262000 NAC4 0 1XI 0.000000 Current Draw from TB3 0.000000 I - 0.000000 Total Standby Load 1 0.305600 Total Alarm Load 2.021 000 F- I Fire-Lite Alarms Page 2 7/10/2009 fl (E)FIre-UTeALarMS by Honeywell MS-9200UDLS Rev.2 Baftery Calculation Note 1: You are fully responsible for verifying these calculations. Note 2: Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet 6ITME111trMalls 24 Hours tell Standby Load Current I 0.30560 Amps x 24 7.334 AH __________________________ Ir MM 5 Minutes Alarm Load Current (Amps) 2.02100 Amps x 0.084 1= 0,170 AH Total Current Load 7.504 AH Multiply by the Derating Factor I 1.2 = x 1.20 Total Ampere Hours Required 9.00 AH ( Recommended Batteries: I BAT-1 2120 - I2AH Batteries Battery Check The batteries can be charged by the MS-9200UDLS Charger. The batteries can be housed in the MS-9200UDLS Cabinet. Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAM current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS 9200UDLS Control Panel: The output current is within the panels limitations. Fire-Lite Alarms Page 3 7/10/2009 Jobsite Information: I FCS-24FS6 /8 8aittery Calculation Reaulated Load in Standby Device Type Number of Devices Current (Amps) Total Current (Amps) Main PC Board I X 0065 0.065 Power Supervision Relays X 0.025 0 Auxiliary Current Draw X = 0 from TB4 Terminals 9 & 10 STANDBY LOAD = 0.065 Reaulated Load in ALARM Device Type Number of Devices Current (Amps) Total Current (Amps) Main PC Board without AC I X 0.145 = 0.145 Power Supervision Relays X 0.025 0 Auxiliary Current Draw X = 0 from 1B4 Terminals 9 & 10 NAG / Output# I I X 0.182 = 0.182 NAC / Output #2 1 X 0. 102 = 0.102 NAC / Output# 3 X 0,102 0.102 NAC / Output #4 1 X 5.10 0.102 ALARM LOAD = I 0.633 Batteni Am[) Hour Calculation Standby Load Current (Amps) _____ Required Standby Time (Typically 24 or 60 Hours) 0.065 X 24, = 1.56 AH Alarm Load Current (Amps) Required Alarm Time (Typically 5 or 10 Minutes) 0.6331 X - 10 = 0.11 AH Sub Total Standby / Alarm Amp Hours 1.67 AH Multiply by the Derating Factor X 1.2 * I Total Ampere Hours Required 2 AH * Derating Factor required to compensate for the non-linear discharge characteristic of a battery. C C SYSTEM $ SENSOR Premises: Beach Terrace Inn 2775 Ocean St. Carlsbad, CA 92008 Prepared By: Bob Atkins Cross Way Fire Protecton 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B @ 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: Wi Circuit Type and Model Candela Current Next Total 12 14 16 18 Mini-Sounder MHW 0.017 147 147 20.34 20.30 20.25 20.16 Mini-Sounder MHW 0.017 14 161 20.33 20.30 20.24 20.14 Mini-Sounder MHW 0.017 14 175 20.33 20.29 20.23 20.12 Mini-Sounder MHW 0.017 14 189 20.33 20.29 20.22 20.11 Mini-Sounder MHW 0.017 14 203 20.33 20.28 20.21 20.10 FZ—Lni-Sounder MHW _F 0.017 i 14 217 I 20.33 20.28 20.21 20.10 Total current/amps 0.102 vdc loss 0.07 0.12 0.19 0.30 'F SYSTEM $ SENSOR Beach Terrace Inn 2775 Ocean St. Carlsbad, CA 92008 Prepared By: Bob Atkins Cross Way Fire Protecton 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B © 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: W2 Circuit Type and Model Candela Current Next Total 12 14 16 18 Mini-Sounder MHW 0.017 130 130 20.35 20.32 20.27 20.19 Mini-Sounder MHW 0.017 14 144 20.34 20.31 20.25 20.17 Mini-Sounder MHW 0.017 14 158 20.34 20.30 20.24 20.15 Mini-Sounder MHW 0.017 14 172 20.34 20.30 20.24 20.14 Mini-Sounder MHW 0.017 24 196 20.33 20.29 20.23 20.13 ni-Sounder MHW 0.017 14 210 20.33 20.29 20.23 20.12 Total current/amps 0.102 vdc loss 0.07 0.11 0.17 0.28 0 r SYSTEM $ SENSOR Beach Terrace Inn 2775 Ocean St. Carlsbad, CA 92008 Prepared By: Bob Atkins Cross Way Fire Protecton 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B @ 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: W3 Circuit Type and Model Candela Current Next Total 12 14 16 18 Mini-Sounder MHW 0.017 147 147 20.34 20.30 20.25 20.16 Mini-Sounder MHW 0.017 14 161 20.33 20.30 20.24 20.14 Mini-Sounder MHW 0.017 14 175 20.33 20.29 20.23 20.12 Mini-Sounder MHW 0.017 14 189 20.33 20.29 20.22 20.11 Mini-Sounder MHW 0.017 14 203 20.33 20.28 20.21 20.10 ni-Sounder MHW 6 0.017 14 217 20.33 20.28 20.21 20.10 Total current/amps 0.102 vdc loss 0.07 0.12 0.19 0.30 :- SYSTEM SENSOR Premises: Beach Terrace Inn 2775 Ocean St. Carlsbad, CA 92008 Prepared By: Bob Atkins Cross Way Fire Protecton 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B @ 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: El Circuit Type and Model Candela Current Next Total 12 14 16 18 Mini-Sounder MHW 0.017 5 5 20.40 20.39 20.39 20.39 Ceiling Strobe SCW 15/75 0.077 9 14 20.39 20.39 20.38 20.36 Ceiling Strobe SCW 15/75 0.077 7 21 20.39 20.38 20.37 20.36 Total current/amps 0.171 vdc loss 0.01 0.02 0.03 0.04 SYSTEM SENSOR Beach Terrace Inn 2775 Ocean St. Carlsbad , CA 92008 Prepared By: Bob Atkins Cross Way Fire Protection 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B @ 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: E2-Circuit Type and Model Candela Current Next Total 12 14 16 18 Wall Horn/Strobe (2 Wire) P2W 15/75 0.08 73 73 20.32 20.28 20.20 20.09 Mini-Sounder MHW 0.017 43 116 20.29 20.22 20.12 19.96 Mini-Sounder MHW 0.017 14 130 20.28 20.21 20.10 19.92 Mini-Sounder MHW 0.017 14 144 20.27 20.20 20.07 19.88 Mini-Sounder MHW 0.017 29 173 20.26 20.17 20.03 19.82 ii-Sounder MHW 0.017 43 216 20.23 20.14 19.98 19.74 ni-Sounder MHW 0.017 14 230 20.23 20.13 19.97 19.71 Mini-Sounder MHW 0.017 14 244 20.22 20.12 19.96 19.69 Mini-Sounder MHW 0.017 20 264 20.22 20.11 19.94 19.67 Mini-Sounder MHW 0.017 14 278 20.22 20.11 19.93 19.66 Mini-Sounder MHW 0.017 14 292 20.21 20.10 19.93 19.65 Mini-Sounder MHW 0.017 17 309 20.21 20.10 19.93 19.65 Total current/amps 0.267 vdc loss 0.19 0.30 0.47 0.75 SYSTEM SENSOR remises: Circuit: Beach Terrace Inn Class B © 14 AWG 2775 Ocean St. Filtered (DC) 24-volt Supply (3 amp circuit) Carlsbad , CA 92008 Starting Voltage = 20.4 Prepared By: Notes: Bob Atkins E3-Circuit Cross Way Fire Protection 2801 Camino del Rio So. #302 San Diego, CA 92108 Type and Model Candela Current Next Total 12 14 16 18 Mini-Sounder MHW 0.017 78 78 20.32 20.27 20.19 20.07 Mini-Sounder MHW 0.017 14 92 20.30 20.25 20.16 20.01 Mini-Sounder MHW 0.017 14 106 20.29 20.23 20.13 19.96 Mini-Sounder MHW 0.017 14 120 20.28 20.21 20.10 19.92 Wall Horn/Strobe (2 Wire) P2W 15/75 0.08 46 166 20.24 20.15 20.00 19.77 Horn/Strobe (2 Wire) P2W 15/75 0.08 8 174 20.24 20.15 20.00 19.76 0mII i-Sounder MHW 0.017 68 242 20.23 20.13 19.97 19.72 Mini-Sounder MHW 0.017 14 256 20.23 20.13 19.97 19.71 Total current/amps 0.262 vdc loss 0.17 0.27 0.43 0.69 0 r SYSTEM SENSOR Premises: Beach Terrace Inn 2775 Ocean St. Carlsbad, CA 92008 Prepared By: Bob Atkins Cross Way Fire Protecton 2801 Camino del Rio So. #302 San Diego, CA 92108 Circuit: Class B @ 14 AWG Filtered (DC) 24-volt Supply (3 amp circuit) Starting Voltage = 20.4 Notes: E4 Circuit Type and Model Candela Current Next Total 12 14 16 18 Ceiling Horn/Strobe PC241575W 15/75 0.091 11 11 20.39 20.39 20.38 20.37 Ceiling Horn/Strobe PC241575W 15/75 0.091 42 53 20.38 20.36 20.34 20.31 Total current/amps 0.182 vdc loss 0.02 0.04 0.06 0.09 df-60415:B • A1-70 MS.9200UDLS(E) Rev 2 FlreuTeALarmS S Intelligent Addressable FACP 0 with Built-In Communicator by Honeywell Addressable [t[4[4 t1 The FireLite MS-9200UDLS Rev 2 with Version 4.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 2 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—FireLite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 5 for specific installation instructions.) The MS-9200UDLS Rev 2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. Version 4.0 firmware supports the following: ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnos- tics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto- resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port u1oai'download, using PS- Tools. Four Style Y (Class B) or two Class A (Style Z) NAC cir- cuits. (Up to 6.0 amps, total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via addres- sable monitor modules or LCD-60F, ANN-80 or ACS Annunciators. ANN-BUS for connection to following, optional modules (can- not be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only ACS/TERM: - ACS Annunciators: Up to 32 ACM Series annunciators (ACM-1 6AT or ACM-32 series).. Cannot be used if ANN- BUS devices are used. - Terminal-mode Annunciators, Up ID 32 LCD-80F remote annunciators. S The integral DACT transmits system status (alarms, supervi- sories, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/Download utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools, the Fire-Lite Upload/Download software kit, may serve as a Ser- vice Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, cur- rent status and system voltages. The panel can also be pro- grammed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. S df-30415'3• 10/14/(38—Page 1 of 6 EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN- 6E Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Watertlow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See wire table on page 5. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to two Class A NACs with NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24V0C system power output is shared among all NAG circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24 VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS(E) Rev 2 in less than one minute. USB programming with standard Male-A to Male-B cable. S Page 2 of 6— df-60415:B • 10/14/08 User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS Rev 2: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD dis- play, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE Rev 2: Same as MS-9200UDLS Rev 2, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. PK-CD: Contains PS-Tools Programming software for Win- dows®-based PC computer (cable not included). DP-9692: Optional dress panel for MS-9200UDLS Rev 2. TR-CE: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 2(E). PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for Internet communications over cus- tomer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet df-60407 or df- 52424 for more information.) S S IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2J2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclosure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF- 60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annuncia- tor: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS Rev 2, see the following data sheets (document numbers) ACM-8RF (DF-5 1555), ACS/ACMSeries (DF-52378), LDM Series (DF-5 1384), LCD-80F (DF-52 185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355HT: Fixed high-temperature detector that acti- vates at 190F/88C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. MS-9200UDLS Remote ACC-25/50 ZS Fire Alarm Microphone Audio Command Control Panel Center o .3 I I SP2O1R Speaker ('J SD355 SP2C Photo Detector I ...... Series i Speaker - LCD 80F lidAD355 Adapt Detector SP?R Series Speaker/Strobe - ANN-80 H355/H355R/H355HT __ Heat Detector 3 P213 Strobe Dual Monito3r0F odie __________ ( -Strobe Power Supply FCPS-24FS6 SD355T FCPS-24F58 Photo/Thermal Strobe MMF-300 Multi-Modules.11 Monitor Module Multi-ModulesouuIes CRF-300-6 Six-Relay Control Module. CMF-300-6 Six-Circuit Supervised Control M-dule MMF-302-6 Six-Zone Interface Module MMF-300-1 0 Ten-Input Monitor Module MMF-302 2-Wire Detector Monitor Module - _$ D350PL/D35ORPL Beam Detector Duct Detector I MS-9200UDLS - ADDRESSABLE FIRE ALARM BG-1 2LX Addressable CONTROL PANEL Manual Pull Station df-60415:B • 10/14/08 - Page 3 of 6 BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D350PL: Photoelectric tow-flow duct smoke detector. D350RPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a 1313•617. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-617. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 2, see the following data sheets (document numbers): AD355 (DF-52386), BG- 12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMFICRF Series (DF-52130), CP355 (DF-52383), 0350PU D35ORPL (DF-52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 Series/MDF-300 (DF-52 121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, S0300(T)/S0350(T) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. . Page 4 of 6— df-60415:B • 10/14/08 Wiring Requirements While shielded wire is not required, it is recommended that all is SLC wiring be twisted-pair to minimize the effects of electri- cal interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the follow- ing table to determine the specific wiring requirements for the SLC. SLC Protocol Wire Requirements Distance in Feet (m) Wire Size Wire Type Twisted-pair, shielded 10,000 feet(3,048 m) 12 AWG (3.31 mm2) Belden 9583, Genesis 4410, Signal 98230, WPW D999 Twisted-pair, shielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Belden 9581, Genesis 4408, Signal 98430, WPW D995 CLIP Twisted-pair, shielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Belden 9575, Genesis 4406, & 4606, Signal 98630, WPW D991 Twisted-pair, shielded 3,225 feet (983 m) 18 AWG (0.78 mm2) Belden 9574, Genesis 4402 & 4602, Signal 98300, WPW D975 Untwisted, unshielded wire, in or out of conduit 3,000 feet (914 m) 12 - 18 AWG (3.31 mm2-0.821 mm2) Non-Plenum (FPLR): Twisted-pair, unshielded 10,000 feet (3,048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP) Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): LiteSpeed Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL MS-9200UDLS Rev 2 Wire Requirements C df-60415:B • 10/14/08 - Page 5 of 6 C SYSTEM SPECIFICATIONS S System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices................................................................8 Electrical Specifications AC Power: MS-9200UDLS Rev 2:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 2E: 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7- 18 AH. MS-9200UDLS Rev 2 cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) or one Style Z (Class A) for a total of four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documen- tation and Fire'Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.3 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.3 amps for powering four- wire smoke detectors. Power-limited. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.12' (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TA-CE): 22.00 (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 270C/60 - 80°F. NFPA Standards The MS-9200UDLS Rev 2 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 2 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:208 MEA: 120-06-E LiteSpeedTM is a trademark; and FireLite® Alarms is a registered trademark of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EN11131111C &MNIIMCIIMNC All specifications are subject to change without notice. QUALITY SYSTEMS S MadeintheU.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 6 of 6— df-60415:13 • 10/14/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:208 Page 1 of 1 CATEGORY: Fire Alarm Control Unit (Commercial) LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Brian.Reynolds2@honeywell.com DESIGN: Models MS-9200UD and *Ms..9200uoLs addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, g1h Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 04-21-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer tolistee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2009 Listing Expires June 30, 2010 I Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division July 8, 2004 DF-52301 • D-025 10 FCPS-24FS6 eFirellTer ALarmS 24 Volt, 6Amp Remote Power Supply S www.firelite.com GENERAL The FCPS-24FS6 is a compact, cost-effective, 6-amp re- mote power supply with battery charger. The FCPS-24FS6 may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expan- sion (to support ADA requirements and NAC synchroniza- tion) or auxiliary power to support 24-volt system acces- sories. The FCPS-24FS6 provides regulated and filtered 24 VDC power to four Notification Appliance Circuits con- figured as either four Class B (Style Y) or Class A (Style A, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable or all resettable or two non-resettable and two resettable. The FCPS- 24FS6 also contains a battery charger capable of charg- ing up to 18 Amp Hour batteries. FEATURES UL Listed NAC Synchronization using System Sensor, Wheelock or Gentex (Commander Series) appliances. Cascadable up to 10 power supplies (four with Gentex) with strobe timing maintained. Operates as a sync follower or a sync generator (default). * See note on reverse side. Contains two, fully-isolated input/control circuits (trig- gered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand- alone mode]). Optional mounting kit, P/N 90286, to internally house addressable SLC control module (CRF-300 or CMF- 300) for alarm activation. Four Class B (Style Y) orfour Class A (Style Z) (with ZNAC- 4 Module) Notification Appliance Circuits. 6.0 A full load output (3.0 A maximum per circuit) in NAC expander mode (UL 864). 4.0 A continuous output in stand-alone mode (UL 1481). In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable or a mix of two and two. Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). Power-limiting technology meets UL power-limiting re- quirements. Form-C normally-closed trouble relay. Fully supervised power supply, battery and Notification Appliance Circuits. Selectable earth fault detection. Section: Power Supplies/Accessories APPROVED 7315-0075:206 LISTED MEA S2424 219-02-E AC trouble report selectable for immediate or 8 hour delay. Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notifica- tion circuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, lockable cabinet (15" [38.1 cm] H x 14.5' [36.8 cm] W x 2.75' [7.0 cm] D). Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. Battery charger may be disabled via dip switch for appli- cations requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product IS09001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. d I I For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. ENGINEERING & MAMIIAC1IIRINC Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52301 07/08/04 - Page 1 of 2 El STANDARDS and CODES The FCPS-24FS6 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Sys- tems (NAG expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand-alone mode). SPECIFICATIONS Primary (AC) Power FCPS-24FS6: 120 VAC 60 Hz, 3.2 A maximum Wire size: minimum 14 AWG (2.0 mm2) with 600V insu- lation. Control Input Circuit Trigger Input Voltage: 9.0 to 32 VDC. Trigger Current: 2.0 mA (16 - 32 V). (per input) 1.0 mA (9 - 16 V). Trouble Contact Rating 5.0 A at 24 VDC. Auxiliary Power Output Specific Application Power - 500 mA maximum. OutputCircuits +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. 4.0 A maximum total continuous current for all outputs (Stand-alone mode). 6.0 A maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit Supports lead-acid batteries only. Float Charge Voltage: 27.6VDC. Maximum Charge Current: 1.5 A. Maximum Battery Capacity: 18 AH. ORDERING INFORMATION FCPS-24FS6 Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions. FCPS-2456RB Replacement mother board PN 90286 FCPS-24F Module Mounting Kit ZNAC-4 Class A (Style Z) NAC option module A77-716B 12/24 VDC end-of-line relay for monitoring 4-wire smoke detector power. BAT-1270 Battery, 12 volt, 7.0 AH (two required). APPLICATIONS Example I Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B (Style Y) outputs or 4 Class A (Style Z) outputs (using the ZNAC-4). In this example, the FACP notification appliance circuits will activate the FCPS-24FS6 when reverse polarity acti- vation occurs. Trouble conditions on the FCPS-24FS6 are sensed by the FACP through the Notification Appli- ance Circuit. Page 2 of 2 - DF-52301 07/08/04 Example 2 Use the FCPS-24FS6 to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS-24FS6 inputs. Example 3 Use addressable control modules to activate the FCPS- 24FS6 versus the FACP Notification Appliance Circuits. This typically allows for mounting the FCPS-24FS6 at greater distances* away from the FACP while expanding system architecture in various applications. In this example, an addressable control module is used to activate the FCPS-24FS6 and an addressable monitor module is used to sense FCPS-24FS6 trouble conditions. Local auxiliary power output from the FCPS-24FS6 pro- vides power to the addressable control module. Tire-Lite's MS-9200, MS-9200UD, (198-point) or MS-9600 (636- point) addressable FACPs have the capability of locating control and monitor modules up to 10,000 feet (3048 m) away. Sync Follower/Generator Note: In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power, which are created by a Fire Alarm Control Panel such as the Fire-Lite MS-9600. When installed at the end of a MS-9600 NAC wire run, this power supply can track (i.e. "follow") the strobe synchro- nization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the addi- tional strobes attached to this power supply. When this power supply is configured (via DIP switch settings) as a "sync follower," this supply's NAC outputs track the strobe synchronization pulses present at this supply's sync input terminal. The pulses are originated from an upstream FACP or other power supply. When this power supply is configured (via DIP switch settings) as a "sync generator," this supply's sync input terminal are not used. Rather, this power supply is the originator of the strobe synchronization pulses on this power supply's NAC outputs. In "sync generator' mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS USTEING PROGRAM LISTING SERVICE CAL LISTING No. 7315-0075:206 Page 1 of 1 CATEGORY: Power Units LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or + recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division S df-52417:b • B-go ANN-80 FWUTGALS 80-Character LCD Serial Annunciator by Honeywell Annunciators I The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Aesthetically pleasing design constructed of durable Lexan. Surface mount directly to wall or to single, double, or 4' square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettale: 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (9C°F ± 3°F). 5.375" 02.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.45 cm.) deep. For use indoors in a dry locatior. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, :ertain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: .92424 FM approved (ANN-80) CSFM: 7120-0075:211 MEA: 442-06-E (ANN-80) The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The AN NI-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. df-52417:b • 05/30/08 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can he located from the FACP ott a single wire ruti. The table ensures 6.0 volts of line drop maximum. In general, the wire length Is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. I fl Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case 22 Gauge Current Draw (amps) 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. 6,000 ft. -6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80: Red, 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W: White, 80 character LCD Annunciator. ANN-BUS and power wiring are supervised and power-limited. = TBI ANN-BUS Device MS-9050UD TB3 I/Ifi'T/I 0 12345678 FACP Wiring to ANN-BUS Device FireLite® Alarms is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENIMMINS & MIIUFAflLUNG All specifications are subject to change without notice. Made in the U.S. A. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— dl-52417:b • 05/30/08 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE En LISTING No. 7120-0075:222 Page 1 of 1 CATEGORY: Annunciators LISTEE: Fire-Lite Alarms, One Fire-Lite Place, Northford, CT 06472 Contact: Brian Reynolds (203) 484-6124 Fax (203) 484-7309 Brian.Reynolds2@honeywell.com DESIGN: Models ANN-LED, ANN-RLED Remote Annunciators, and ANN-RLY Relay Module. Models ANN-LED and ANN-RLED provide remote annunciation of up to 10 inputs (ANN- LED) and 30 inputs (ANN-RLED). Model ANN-RLY relay module provides 10 programmable Form C relays. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. P, MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as annunciators or relay module for use with listee's separately listed fire alarm control units. Refer to Manufacturers Installation Instruction Manual for details. 04-16-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ; recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division (3 Flre•uTe®ALarms A PTIWAY COMPANY BG-12LX Addressable Pull Station Document 51094 Revision A2 ECN 00-03 01/14/2000 S Descript.on The BG-12LX Addressable pull station is a non-coded, dual-action manual pull station with a key-lock reset fea- ture. I t provides Fire-Lite intelligent control panels with one addressable alarm initiating input. The addressable module is housed inside the pull station. The BG-12LX is compatible with all Fire-Lite intelligent ran.-Is. The BG-12LX meets the ADA requirement fo- a 5-lb. maxi- mtm pull force to activate the pull station. Operating instructicns are molded into the pull statio:i handle along with Braille text. Molded Terminal numbers are also preser.t. Installation The EG-12LX Addressable pull station car: be surface mounted to an SB-10 surface backbox or semi-flush mounted on a standard single-gang, double-gang or 4" (10.16 cm) square electrical box. The optional BG-TR trim r: ng can be used if the BG-12LX is tc be semi-flush moun:ed Ratings Normal Operating Voltage: 24 VDC. Average Operating Current (LED Flash): 300 I.LA. Temperature Range: 320 F - 1200 F (00 C - 490 Q. 0 Relative Humidity Range: 10% - 93% non-condensing. Setting the BG-12LX Address The BG-12LX Addressable pull station is factory preset with address '00.' Set the address for the pull station by turning the rotary address switches on the addressable mod- ule mounted inside the pull station. Only one device per address is allowed. Multiple modules may not be set to the same address on the Signaling Line Circuit. Once the address is set, record it in the space provided on the prod- uct ID label located inside the pull station. ROTARY ADDRESS SWITCHES LED OPERATION LED 1= Normal: Flash RED Alarm: Steady RED If, during mounting of the pull station, the door be- comes detached, complete the following steps to reattach the door to the backplate. The door cannot be connected to the pull station if the unit is mounted to the backbox. Position the door and backplate side by side in the full open position. (i.e. 180-degrees with respect to each other.) With the backplate position fixed, move the door be- hind the backplate, as shown in the illustration, part A. Align the hinge posts and holes by bringing the door up to meet the backplate, paying particular attention to the 'keying' that occurs when the door's post hole is aligned to the backplate's hinge post. Refer to the illustration, part B. With the two pieces aligned and 'keyed' together, slide the holes down onto the posts. Refer to the illustra- tion, part C. Holding the backplate, close the door and backplate slightly to lock the door and backplate together. Note: LED is visible through translucent handle. To Next Addressable From Device Wiring If flush mounting, proceed to step 4. Mount the backbox before wiring it to the pull station. Before surface mounting the pull station, pull all wiring through the backbox and optional trim ring. Remove the appropriate amount of wire insulation. The pull station back plate is molded with a strip gauge to measure the amount of insulation to be removed. Connect the wiring from the addressable fire alarm control panel's Signaling Line Circuit (SLC) to Terminals 1(-) and 2(+) on the BG-12LX addressable pull sta- tion. SLC polarity is critical for this connection. Connect the wiring going to the next device on the SLC to Terminals 1 and 2, again being certain to observe polarity. Open the pull station door; align the mounting holes of the pull station backplate to the backbox and screw into place. Tighten top and bottom screws. Set the address as described in 'Setting the BG-12LX Address' and write the address in the space provided on the label. Insure that the alarm switch is in the normal position. Close and lock the pull station door. Push-in and pull-down the handle where indicated to activate the station. The BG-12LX manual fire alarm pull station includes one SPST (Single Pole, Single Throw) N/O (normally-open) switch and the addressable mod- ule located inside the station. Pushing-in and pulling-down the dual action handle causes the NIO alarm switch to close. The word 'ACTIVATED' is displayed on the top of the handle when the pull station handle is Pushed-in and pulled-down. The activated handle can not be reset without employing the key-lock reset. To reset the BG-12LX pull station: 1) Insert the key and turn counterclockwise, 2) Open the door until the handle *m oves back into the 'NORMAL' position, 3) Close the door and lock it. Closing the door automatically resets the BG-12LX to the 'NORMA' position. Note - Opening the pull station door will not activate or 1 ............ ===. deactivate the alarm switch. ACTIVATED BG-12LX PULL STATION Closing the door slightly locks the door and backplate together. DOOR MATED TO BACKPLATE CAUTION! Install the Fire-Lite BG-12LX manual pull station in accordance with these instructions, applicable NFPA standards, national and local Fire and Electrical codes and the requirements of the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- ducted in accordance with the appropriate NFPA standards. Failure to follow these directions may result in failure of the device to report an alarm condition. Fire-Lite is not responsible for devices that have been improperly installed, tested or maintained. For ADA compliance, if the clear floor space only allows forward approach to an object, the maximum forward reach height allowed is 48 in. (1,220 mm). If the clear floor space allows parallel approach by a person in a wheelchair, the maximum side reach height allowed is 54 in. (1,370 mm). Document 51094 Revision A2 ECN 00-032 01/14/2000 a CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:184 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds (203) 484-7161 FAX (203) 484-7309 DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LIA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-125L, UT-PSi and UT- PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. S MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:199 *Updated 06-22-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or *; recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division df-523E4:al • E-160 S SD355(A), SD355T(A) Addressable Photoelectric Smoke Detectors 8 FlreLrre°ALarms by Honeywell Addressable Devices [c11I;fl [iJ The SD355(A) and SD3551(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Address- able Fire Alarm Control Panels (FACPs). The SD3551(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA400Z). FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with MS-9200 series, and 01 - 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). SD355 with B35OLP base S03551 with B35OLP base APPLICATIONS Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better ti-an photoelectric detectors at sensing fast flaming fires. CONSTRUCTION These detectors are constructed of oft-whhe LEXAN®. SD355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. INSTALLATION SD355(1) plug-in detectors use a detachable moun:ing base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring 4.0" (10.16 cm) octagonal box. 3•5fl (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, er,d-o f-line resistors are not required. Wirng 'T-taps" or branches are permitted for Style 4 (Class B) wiring. df-52384:al • 05t3/09 - Page 1 of 2 OPERATION Each SD355(T) uses one of 99 possible addresses on the MS- 9200 series and up to 318 (159 on each loop) on the MS-9600 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The SD355(T) addressable photoelectric sensor's unique uni- polar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the 5D355(T) is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 10 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 series or MS- 9600 series for record keeping. SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: '6.5 m @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 m/sec.) maximum. Diameter: 6.1 (15.5 cm) installed in B350LP base Height: 2.1 (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 1200F); for S0355T(A):01C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. LISTINGS Listings and approvals below apply to the SD355(A) and SD355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059. ULC Listed, file S6963. CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. PRODUCT LINE INFORMATION NOTE: "A" suffix indicates ULC-Listed mode!. SD355: Adressable photoelectric detector; B350LP base included. SD355A: Sames as SD355 with ULC Listing (B350LPA base included). SD355T: Same as SD355 but with thermal element; B350LP base included. SD355TA: Same as SD355T with ULC Listing (B350LPA base included). B350LP(A): Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB(A): Plug-in System Sensor relay detector base. Diameter. 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BH-2(A): Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). B501 BHT-2(A): Plug-in System Sensor temporal tone sounder detector base. ACCESSORIES: RA400Z(A): Remote LED annunciator. 3 -32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B35OLP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-2006: Black detector covers, box of 10. wCK-200B: White detector covers, box of 10. FlashScan® registered trademark of Honeywell International Inc. Bay- blend is a registered trademark of Bayer Corporation. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. NIMNS & 11111111111111AM1111119 All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 - df-52384:al • 05/8/09 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:194 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Fire-Lite Alarms Inc., One Fire-Lite Place, Northford, CT 06472 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models SD350, SD350T, SD355, SD355T and AD355 photoelectric type smoke detectors. Model SD350T and S0355T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 05-06-05 BH " This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division df-52385:A• E-710 H355(A) Series AreuTeGAtarms Intelligent Addressable Thermal Detectors by Honeywell AddressableDevices General The Fire.Lite Alarms H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open-area protection and are intended for use with the FlreLite's addresable Fire Alarm Control Panels (FACP5). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (57°C). The 11355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (880C). These thermal detectors provide cost effective, addressable property protec- tion in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 159 with MS-9600, 01 —99 with MS-9200U0. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). 3600-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. .. H355 with B35OLP base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA400Z remote LED annunciator. Recessed (RMK400) or surface (SMK400E) base mount- ing kits. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box that is at least 1.5° (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box. 3.5° (8.89 cm) or 4.0" (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white Bayblend®. The H355(A) Series plug-in intelligent thermal detectors are designed to commercial standards and offer an attractive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600) or 99 (MS-9200UD) possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its elec- tronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that repre- sent the latest in thermal detector technology. df-52385:A • 12/17/08 - Page 1 of 2 [1 Specifations Diameter: 6.1 (15.5 cm) installed in B350LP(A). Height: 2.1" (5.33 cm). Weight: 4.8 oz. (137 g). Installation temperature: -4°F to 100°F (-20°C to 38°C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA@ 24 VDC. Mounting: 133501_13(A) flanged base, included. Fixed-temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. MEA approved: file 387-02-E UL Listed, file S2517 ULC Listed (models H355A, H355RA, H355HTA) CSFM approved: file 7270-0075:195 FM approved Product Line Information NOTE: "A" suffix indicates ULC-Listed model. H355: Intelligent thermal sensor; B350LP base included. H355A: Same as H355 but with ULC Listing (13350LPA base included). H355R: Same as H355 with rate-of-rise feature; B350LP base included. H355RA: Same as H355R but with ULC Listing (13350LPA base included). H355HT: Intelligent fixed high-temperature thermal detector; B350LP base included. H355HTA: Same as H355HT but with ULC Listing (133501-17A base included). B350LP(A): Plug-in detector base (included). Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). 6224RB(A): Plug-in System Sensor relay detector base. Diameter.-6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5' (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter.-6.2" (15.75 cm). Mounting:4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BH-2(A): Plug-in System Sensor standard sounder base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BHT-2(A): Plug-in System Sensor temporal tone sounder base. ACCESSORIES: RA400Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B350LP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with B501 (A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. Bayblencl@ is a registered trademark of Bayer corporation. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. fflUtlNI 8 MNNFAMING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. www.firelite.com Page 2 of 2- df-52385:A • 12/17/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7270-0075:195 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Fire-Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models H350, H355, and H355HT fixed temperature heat detectors. Models H350R and H355R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: H350, H355, and H355HT 135° F fixed temperature H350R and H355R 15° F rate-of-rise H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Rev. 05-06-05JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division SIGHAUNG ®$MEA LISTED APPROVED approved S4011 3023372 MEA452-00-E 55512 53593 0 7125-I653:I867ndoo, 11,ob,,) 73-I653I87 ou1d00, 11106,1) 7I28'1653.I88thorn/,irob:, 7135-1653:189 OlolnI, h,rne,) f SYSTEM SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. fl Features Electrically compatible with existing SpectrAlert products Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Plug-in design The SpectrAlert Advance series of no:ification appliances .s designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installaticr of individual devices, and 1 eld-selectable candela settings for vall and ceiling strobes and horn/strobes. Field selectable candela settings on wall and ceiling units: 15, 15/75, When installirg Advance products, first at:ach a universal mounting 30, 75, 95, 110, 115, 135, 150, 177, 185 plate to a four-inch square. four-inch octagon or double-gang Same mounting plate for wall- and ceiling-mount units Junction box, The two-wire mounting plate attaches to a single-gang • Shorting spring on mounting plate for continuity check before junction box. installation Next, connect the notification appliance circuit wiring to the SEMS Tamper resistant construction terminals on vie mounting plate. Outdoor wall and ceiling products rated from —40°F to 151°F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products NEMA 4X rated Compatible with MDL sync module Agency Listings Finally, attach the horn, strobe or horn/strobe to the mounting plate hi inserting the product' tabs in the mounting plate's grooves.—he device will rotate into position, locking the product's pins into the mounting plate's terminals. The device wit temporarily hold in. p'ace with a catch Lntil it is secured with a caotJred mounting screw. Tie Spec:rAlert Advance series includes c utdoor notification aipliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wail or ceiling. OLtcoor horns are availaLle for wall only. All Eystem Sensor outdoor procucts are rated between minus 40 decrees Fahrenheit and 151 degrees Fahrenheit in wet or d-y applicaticns. SpectrAlert Advance General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model_ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 H and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a • single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/s-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. 1111 MINE iiippi IIrI!7T1L1tiTk.ii Standard Operating Temperature 32F to 120F (0CC to 49CC) K Series Operating Temperature —407 to 151 ¶ (-40CC to 66C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DCJFWR' Operating Voltage Range' 8 to 17.5 V 02V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61. x 4.7W x 2.5D (142 mm Lx 119 mm W x 64 mm 0) Horn dimensions . 5.61. x4.TWx 1.312(142 mm 11919mrnWx 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.91. x 5.01W x 2.212(151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2) 7.1 * diameter x 2.25 high (180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.71. x 5.1W x 2.012(145 mm L x 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 7.1" diameter x 2.0 high (180 mm diameter x 51 mm high) Wall-mount trim ring dimensions (TR-HS, TRW-HS) 5.71. x 4.8121W x 0.3512 (146 mm Lx 122 Wmm x 9 D mm) Ceiling-mount trim ring dimensions (TRC-HS,TRCW-HS) 6.9diameter x 0.35 high (176 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 0 Switch VOltS VOltS tseveroerant Anecnoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 13' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2-wire horn/strobe. A05-0395-COS Strobe Output (cd) Listed Candela Candela rating at _40*F 15 Do not use below 32*F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 0 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d8 DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 1633 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 (80; 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 1 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (rnA RMS), 2-wire HornIStrobe, High Candela Range (135-18.5~cd),5"E:'~~"" 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. SpectrAlert Advance zz, Wall-mount horn/strobes Ceiling-mount horn/strobes 71 Dia. I.— 5.05—.1 2.231 00 0 Q Dia 5•9 I I N ckJo u 5.1 .1 Wan weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall back box skirt Ceiling back box skirt S Wall Horn/Strobes P2Rt 2-wire Horn/Strobe, Standard cd*, Red P2RH 2-wire Horn/Strobe, High cd, Red P2RK" 2-wire Horn/Strobe, Standard cd, Red, Outdoor P21RHK" 2-wire Horn/Strobe, High cd, Red, Outdoor P2W 2-wire Horn/Strobe, Standard cd, White P2WH" 2-wire Horn/Strobe, High cd, White P4R 4-wire Horn/Strobe, Standard cd, Red P4RH 4-wire Horn/Strobe, High cd, Red P4RK" 4-wire Horn/Strobe, Standard cd, Red, Outdoor P4RH1<" 4-wire Horn/Strobe, High cd, Red, Outdoor P4W 4-wire Horn/Strobe, Standard cd, White P4WH 4-wire Horn/Strobe, High cd, White Wall Strobes SR Strobe, Standard cd, Red SRHat Strobe, High cd, Red SRK" Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW Strobe, Standard cd, White SWH Strobe, High cd, White Ceiling Horn/Strobes PC2R 2-wire Horn/Strobe, Standard cd, Red PC2RH 2-wire Horn/Strobe, High cd, Red PC2R10 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK" 2-wire Horn/Strobe, High cd, Red, Outdoor (PC2W*t i 2-wire Horn/Strobe, Standard cd, White PC2WHt 2-wire Horn/Strobe, High cd, White PC413 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK" 4-wire Horn/Strobe, High cd, Red, Outdoor Ceiling Horn/Strobes (cont'd.) PC4W 4-wire Horn/Strobe, Standard cd, White PC4WH 4-wire Horn/Strobe, High cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCRK" Strobe, Standard cd, Red, Outdoor SCRHK" Strobe, High cd, Red, Outdoor 1SCWw Strobe, Standard cd, White SCWHat Strobe, High cd, White Horns HR Horn, Red HRK" Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White Notes: Add "-Pta model number for plain housing (no"FlREmarking on cover), e.g., P2R-P. t Add "-SP"to model number for "FUEGO"marking on cover, e.g., P2R-SP. * "Standard cdrefers to strobes that include iS, 15/75,30,75,95, 110, and 115 candela settings. "High cd,"refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "K"include a weatherproof back box. Add "-R" to model number for weatherproof replacement device (no back box included). \ 3\825 Ohio Avenue. St. Charles, IL 60174 02 8Sys(emSenso, V.) Phone; 800-SENSOR2 . Fax: 630-377-6495 A05-0395-COS - 8/03 - 42018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS USTING PROGRAM LISTING SERVICE LISTING No 7135-1653:189 Page 1 of 1 CATEGORY Audible Devices LISTEE System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com DESIGN: Models HR, HW Horns and CHR, CHW chimes. Intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (40 Degrees C to +66 Degrees C) and are rated NEMA *4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Models CHR and CHW are intended for private mode use only. Suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8 - 17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. "Rev 12-01-08 bh ° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or A. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:186 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 x 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCWCLRALERT* and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 05-04-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator 0 Fire Engineering Division S LISTING No. CATEGORY LISTEE: DESIGN: S RATING: INSTALLATION MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-1653:188 Page 1 of 1 Fire Alarm Devices for the Hearing Impaired System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure: Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (-40 Degrees C to +66 Degrees C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SAWBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator 5 Fire Engineering Division YSTEM $ -SENSOR Mini-Horns F :s The SpectrAlertAdvance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features 12 and 24V operation High and low volume settings Temporal and non-temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini-Aerr sounders The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supplyThey are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings & <~' MEA . LISTED APPROVED approved .4OII 38OO I.--L SpectrAIert Advance Mini-Horn Specifications . -......................--.... -.-'-...-..".-.. Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12or24VDC and shall mount to a single gang back box. Mini- horn shall be hated to Underwriters Laboratories Standard UL464 for fire protective signaling systems. Mini-harts shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync-Circuit- Module, 12-volt rated notflcation appliance ciicuit outouls shall operate betweeii nine and 1.1.5 vulls; 24-vail rated i lolilluelion appikince TI cue OUlotils shall operate between 1 7 and 33 volts. Physical Specifications Dimensions °1ELx 2.9'Wx 35D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: single-gang back box Flush: 4" x 4 BAD deep back box (7~ deep InputTerminals 12to18AWG Nominal Voltage Regulated 12D0'FWR or regulated 240G'FWR Operating Voltage 8-33 with MDL 933 UL Sound Output and Current Draw Data P.rr7s1T11j4aL Switch Settinq Pattern Output Level 8-17.5VDC 8-17.5VFWR Nominal 12VDC Nominal 12VFWR 16-33VDC 16-33VFWR 1 lémporal High 68 67 71 70 78 76 2 Temooral Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 S 4 Non-temporal Low 70 69 73 72 78 77 8--17.5 Volts 16--33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 j 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temooral Low 17 13 21 19 Information MHR Mini-Horn, Red MHW Mini-Horn,White S''S7ERfl 3825 Ohio Avenue. Si. Charles, 1L60174 S fs!SOR Phone: 800-SENSOR2 Fax: 630-377-6495 '- S LISTING No. CATEGORY LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:196 Page 1 of 1 Audible Devices System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 fl DESIGN: Models MHR, MHW and APA151 horns. The Model APA151 is a remote sounder intended to be connected to the alarm indicating circuit of listed duct smoke detectors. All units are for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: APA1 51: Regulated 24 VDC Operational 16-33 Volts, 30mA MHR and MHW: Regulated 12V DC/FWR and 24V DC/FWR Operational 8-17.5 and 16-33 Volts, 18mA at 12V and 30mA at 24V Audibility: MHR and MHW Tones 1, 2, 3 & 4 are Public Mode at 24V DC/FWR Tone 3 is Public Mode at 12V DC Tones 1,2 & 4 are Private Mode at 12 V DC Tones 1, 2, 3 & 4 are Private Mode at 12V FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models MHR and MHW are listed as an audible signal appliance for use with separately listed compatible fire alarm control units. Model APA1 511s listed as an accessory horn for use with separately listed 4-wire conventional duct smoke detectors. (REF: 3240-1653:119) Refer to manufacturers Installation Manual for details. 03-15-07 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;+ recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division