Loading...
HomeMy WebLinkAbout2701 OCEAN ST; ; AS150138; PermitCity of Carlsbad Sprinkler Permit Permit No: AS 150138 Job Address: 2701 OCEAN ST Permit Type: SPRINK Parcel No: 2031403800 Lot #: 0 Reference No.: PC #: Project Title: DEAN RESIDENCE SFR Status: APPROVED Applied 5/12/2015 Approved: 5/13/2015 Issued: 5/13/2015 Inspector: Applicant: ALWAYS FIRE PROTECTION 1451 KENT AV. ESCONDIDO, CA 760-294-4525 Owner: DEAN TOMMY M TRUST 03-14-05 4517 ADAMS ST CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 280 0 280 0 AS 150138 HYDRAULIC DESIGN INFOF,1,. Name: Dean Residence Location: 2701 Ocean Street Carlsbad, CA 92008 Building: Contractor: Berry Smith & Associates File Name: Dean Res 4-7-15.the Construction: Z Combustible fl Noncombustible Occupancy: Single Family Dwelling AHJ: Carlsbad Fire Department Date: April 07, 2015 System No: Contract No.: Drawing No.: Calculated by: B. R. Ceiling Height: 8'-1" ft SYSTEM DESIGN O NFPA 13: D Light Hazard fl Ordinary Hazard Group: fl Extra Hazard Group: Figure: Curve: nX Other (Specify): NFPA 13D F1 Srecific Rullina: - Made By: Date: Area of Sprinkler Operation: 256 sqft System Type: EI Wet 0 Dry 0 Delugee-Action Density: .05 gpm/sqft lf~ CW Area per Sprinkler: 256 sqft SPRINKLER or NOZZLE Hose Allowance Inside: gpm Make: Tyco Model L II l Hose Allowance Outside: gpm Size: .5 in K-factor: 9 Rack Sprinkler Allowance: gpm Temperature Rating: 160 OF ) U) CALCULATION SUMMARY Flow Required: 31.04 gpm Pressure Required: 55.23 psi At: SRC "C" Factor Used: Overhead: 150 Underground: 150 L__1qJ WATER SUPPLY WATER FLOW TEST PUMP DATA TANK ORRESER1 Date: 4-2-15 Rated Capacity: gpm Capacity: gals Time: 8:30 AM At: psi Elevation: ft Static: 74 psi Elevation: ft Residual: 73 psi WELL Flowing: 52 gpm Proof Flow: gpm Elevation: 41 ft Location: 2701 Ocean Street Carlsbad, Ca 92008 Source of Information: Carldbad Municipal Water Linda 760-602-2750 COMMODITY STORAGE Commodity: Class: Location: Storage Height: Area: Aisle Width: Storage Method: Solid Pile: % Palletized: % Rack: % RACK STORAGE O Single Row O Double Row El Multiple Row FLUE SPACING Longitudinal: O Conventional Pallet O Slave Pallet in Transverse: o Automatic Storage O Solid Shelving 0 Open O Encapsulated 0 Nonencapsulated CLEARANCE FROM TOP OF STORAGE TO CEILING in ft in Horizontal Barriers Provided: / = - - > - - -1 - :2 7 12.81 ft/sec in the pipe between Nodes: BFI and BF2 0.01 gpm Fitting Type Legend E = 90 degree elbow I = Tee - Flow thru branch H = Tee - Flow thru run C = Check valve U = Flow Indecater N = 90 degree elbow M = 45 degree elbow File: Dean Res 4-7-15.the Page 1 of I Hydraulic Summary WATER SUPPLY INFORMATION Static (psi): 66.60 Residual (psi): 65.70 © (gpm): 52.00 Hose (gpm): 0.00 System req. (gpm): 31.04 @ (psi): 55.23 Supply available: 66.25 psi Safety margin: 11.02 psi Maximum velbcity in the system is: Continuity at all nodes satisfied to: Pipe Type Legend CP = Central - BlazeMaster CPVC CL = Copper Type L PP = PVC CK = Copper Type K NOTES 04/07/15 "THE" Sprinkler Program 2001 File: Dean Res 4-7-1 5.the Page 1 of I Node Pressure Flow Hose Elevation K-factor Area Density psi gpm gpm feet gpm/(psi)Y2 sqft gpm/sqft 1 7.05 13.00 57.650 4.90 25600 0.051 2 7.10 13.04 57.650 4.90 256.00 0.051 A 7.46 0.00 57.650 Al 7.51 0.00 57.650 A2 9.95 0.00 57.650 A3 8.07 0.00 57.650 A4 8.35 0.00 57.650 B 12.55 0.00 48.570 BI 12.82 0.00 48.570 82 14.11 0.00 48.570 TOR 14.53 0.00 48.570 BOR 19.59 5.00 5.00 40.400 BF1 42.36 0.00 43.000 BF2 29.01 0.00 41.000 UI 24.58 0.00 36.900 U2 42.82 0.00 43.000 SRC 55.23 31.04 41.000 Source 04/07/15 "THE" Sprinkler Program 2001 File Dean Res 4-7-1 5.the Page 1 of Node Node Flow K-factor Elevation Pressure Diameter Length Fric Loss Node Node Flow K-factor Elevation Pressure HWC Fittings Eqv Length Elev Loss Pipe Flow Velocity itt Length itt FL 1 13.00 4.90 57.65 7.05 1.101 3.300 0.031 A 0.00 57.65 7.46 150 E I 10.000 0.00 13.00 4.38 13.300 0.41 2 13.04 4.90 57.65 7.10 1.101 3.300 0.031 Al 0.00 57.65 7.51 150 E I 10.000 0.00 13.04 4.40 13.300 0.41 A 0.00 57.65 7.46 1.101 11.650 0.002 Al 0.00 57.65 7.51 150 H 21 11.000 0.00 3.19 1.07 22.650 0.05 Al 0.00 57.65 7.51 1.101 30.690 0.046 A2 0.00 57.65 9.95 150 3E 2H I 22.000 0.00 16.23 5.47 52.690 2.44 A 0.00 57.65 7.46 1.101 24.800 0.018 A3 0.00 57.65 8.07 150 4H I 9.000 0.00 9.81 3.31 33.800 0.62 A3 0.00 57.65 8.07 1.101 10.370 0.018 A4 0.00 57.65 8.35 150 E 5.000 0.00 9.81 3.31 15.370 0.28 A2 0.00 57.65 9.95 1.101 9.080 0.046 TOR 0.00 48.57 14.53 150 I 5.000 3.93 - 16.23 5.47 14.080 0.65 A4 0.00 57.65 8.35 1.101 9.080 0.018 B . 0.00 48.57 12.55 150 E 5.000 3.93 9.81 3.31 14.080 0.26 B 0.00 48.57 12.55 1.101 8.890 0.018 BI 0.00 48.57 12.82 150 H I 6.000 0.00 9.81 3.31 14.890 0.27 Bl 0.00 48.57 12.82 1.101 56.790 0.018 B2 0.00 48.57 14.11 150 9H I 14.000 0.00 9.81 3.31 70.790 1.29 B2 0.00 48.57 14.11 1.101 17.240 0.018 TOR 0.00 48.57 14.53 150 H I 6.000 0.00 9.81 3.31 23.240 0.42 BOR 5.00 40.40 19.59 1.101 8.170 0.111 TOR 0.00 48.57 14.53 150 C U 5500 3.54 26.04 8.78 13.670 1.52 04/07/15 "THE" Sprinkler Program 2001 File: Dean Res 4-7-I5.the Page 2 of 2 Node Node Flow K-factor Elevation Pressure Diameter Length Fit Loss Node Node Flow K-factor Elevation Pressure HWC Fittings Eqv Length Elev Loss - Pipe Flow Velocity Ttl Length Ttl FL UI 0.00 36.90 24.58 1.025 7.000 0.217 BOR 5.00 40.40 19.59 150 3N 9.000 1.52 31.04 12.07 16.000 3.48 BF2 0.00 41.00 29.01 1.101 27.000 0.153 Ui 0.00 36.90 24.58 150 2E 13.416 -1.78 31.04 10.46 40.420 6.20 BFI 0.00 43.00 42.36 0.995 7.170 0.251 BF2 0.00 41.00 29.01 150 3N 2C 17.000 -0.87 31.04 12.81 24.170 14.22 The Flow Dependent Pressure Loss Device in this pipe accounts for 8.14 psi of the total friction loss. U2 0.00 43.00 42.82 0.995 1.830 0.251 BF1 0.00 43.00 42.36 150 0.000 0.00 31.04 12.81 1.830 0.46 SRC 31.04 Source 41.00 55.23 0.995 28.000 0.251 U2 0.00 43.00 42.82 150 2M 2.000 0.87 31.04 12.81 30.000 11.55 The Flow Dependent Pressure Loss Device in this pipe accounts for 4.01 psi of the total friction loss. Units Legend Flow = gpm Velocity = ft/sec Fric Loss = psi/ft Elevation = feet Length, Elev Loss, Presure = psi Eqv Length, Ttl FL = psi Diameter = inches Ttl Length = feet 04/07/15 "THE" Sprinkler Program 2001 Water Supply vs. Sprinkler Demand 90 - 80 70 52 @66 31 @55 60 50 30 20 ic 0 20 40 60 80 100 120 140 Flow (gpm) tqa~no Fire Protection Products Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential Sprinklers 49 K-factor Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-family dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprin- kler systems for residential occu- pancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLEF? WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFII Residential Pendent and• Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan- dards of the National Fire Protection Association, in addition to the stan- dards of any authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condi- tion. Contact the installing contractor or sprinkler manufacturer with any questions. FEBRUARY 2014 Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 4.9 GPM/psi1/2 (70,6 LPM/bar112) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass Pure or Signal White Chrome Plated Physical Characteristics Frame .............................Brass Button............................Copper Sealing Assembly ................Beryllium Nickel w/TEFLON Bulb (3 mm) ........................Glass Compression Screw ................Bronze Deflector .......................... Bronze Ejection Spring...............Stainless Steel TFP400 TFP400 Page 2 of 6 7/16" (11,1 mm) 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA.________ 1 - Frame 2 - Button MAKE-IN SURFACE (73,0 mm) 4-Bulb 5 - Compression 2 2-1/4 Screw 6 - Deflector* (57,2 mm) 3 - Sealing Assembly 1 ESCUTCHEON RENCH 1-5/8 I STYLE 20 (41,3 mm) w 3 —0 RECESSED * Temperature :iii FLATS rating is indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING 2-7/8 DIA. (73,0 mm) I 1/2(12,7mm) 2-1/4 DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING WR ENCH RECESS (END "A' USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH MOUNTING SURFACE CLOSURE TY2234 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFIl Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. 1/8 (3,2 mm) 1-3/8" (34,9 mm) 1-1/8 (28,6 mm) Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER TFP400 Page 3 of 6 given in Tables A and B as a func- tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (1Y2234) in dry pipe sprin- kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli- cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor- dance with this section: General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Max. Coverage Ordinary Temp. Rating Intermediate Temp. Rating Minimum Area (a) 155°F (68°C) 175°F (79°C) Deflector to Installation Spacing Flow Pressure Ft. x Ft. Flow Pressure Ceiling Type Ft. (m x m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4inches 14x14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 16x16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x 18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating ______________________ Intermediate Temp. Rating Coverage Area (a) 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure (m x m) Ceiling Type Ft. GPM PSI GPM PSI (m) (Limin) (bar) (L/min) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 14 X 14 (4,3 x 4,3) 14 (53.0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) 4 inches Beamed Recessed using Style 20 16x16 15 9.4 15 9.4 Ceilings per Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) NFPA 13D or13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFI1 RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing afire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other- wise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFll (TY2234), K = 4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify): 155°F (68°C) Natural Brass ..............P/N 51-201-1-155 Pure White (RAL 9010)' ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated .............P/N 51-201-9-165 175°F (79°C) Natural Brass ..............P/N 51-201-1-175 Pure White (RAL 9010)' ......P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated ...... ....... P/N 51-201-9-175 'Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) 'Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqc TEFLON is trademark of The DuPont Corporation. Fire Protection Products Ali °Apo.Qivaives SUBMITTAL -Model DCLF 4A flt-u shle Check Values IX STANDARD MATERIALS LIST Part Name Material Body, Caps, Ball Valve 5hutoffsjest cocks 910112e C89836 (lead Fcee) Check Valve Cartridges Glass-Filled PPO Springs 300 Series Stainless Steel Seat Discs chloramine-resistant Silicone 1 0-rings (hloramine-resistant EPDM Job Name: Jobtocation: Engineer Coirtmctor Tag: 110 Number Representative: Wholesale Distributon DESCRIPTION The Apolloe Model DCLF4A Lead Free* Double Check Valves prevent contamination of the potable water supply due to back-siphonage or backpressure from substances that are objectionable to the potable water supply, but non-health hazards. The top accessed modular check valve cartridges provide captured springs, replaceable seats and reversible silicone seat discs. This Made in America assembly features Apollo ball valves with stainless steel handles and nuts as standard and carries the five-year Apollo' factory warranty. FEATURES Low pressure loss documented by independent approval agencies - Easily removable modular check valve cartridge Captured stainless steel springs Apolloa ball valves W/ 55 handles & nuts standard Top-mounted test cocks for easy testing No special tools required Chloramine-resistant elastomers Designed, cast, machined, assembled and tested IN THE USA PERFORMANCE RATING Maximum Working Pressure 175 psi Temperature Range 33 F —180°F APPROVALS ASSE 1015- Horizontal and Vertical Flow Up (W'-2") - CSA 8.64.5 - Horizontal and Vertical Flow Up (W-2') Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California - Horizontal and Vertical Flow Up (W'-21 DIMENSIONS Model Number Sire (in.) Dimensions (in.) Wt. (lbs.) A IA,l B C D 4ALF-103-72F 1/2" 11-1/8 12-9132 114-9132 7-3/8 3-1/4 2-1/2 4.4 4ALF-104-12F 3/4" 12-3/4 8-1/2 3-1/2 3 60 4ALF-105-72F 1" 14-5/8 16-7/32 9-1/2 4 3-1/4 10.0 4ALF-106-72 1-1/4" r18-518 20-5/32 1-3/4 4-1/2 4-314 14.0 4ALF-107-72 1-1/2" 118-3/4 20-31132 11-5/8 4-1/2 4-314 17-0 4A1.F-108-72 r 21-1/8 22-13/16 12-3/4 5 5-3/8 25.4 - B * LEAD FREE: The wetted surfacesofthis product shall contain no more than 0.25% lead Apollo Valves, Manufactured by Conbraco Industries, Inc. by weighted average. Complies with CA 481953. VTAct 193, MD 1413372, LAHB47I and 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA Federal Public Law 111-380. ANSI 3rd party approved and listed. www.apollovalves.com ) (704) 841-6000 Thespd&atwniuyiedfwafezenceon!y (snroco1nthuVia Inz.raava ealcurw affaaemturthemalcwtis(wmgtrn SS1206©03/14 Paael of 2 18 16 14 9 12 0 20 18 g 16 14 9 12 4 Apø&"aves SUBMITTAL ' —Model DCLJF 4A Double Check Valves FACTORY CODE Y-STRAINER I SIZE 4A = Standard 10 0= Standard ID 3= i!2' 4A[F= Lead Free ID 1= wlY-strainer 10 4= 3I4 (shipped loose) 0 5= r D 6= 1-114 10 7= 1-1)2 D 8=2 FLOW CURVES Meter Rated Flow 7.51p112' 7.5fps 314' SHUT-OFF VALVES I OPTIONS (CAN BE COMBINED) 0 1= less hail valves (Uldassified 314"-21 0 F = SAEtlireadedtest cocks (standard 1/29I4 10) El 2= w/ball valves (Standard) 0 11= locking (ever handles 0-1/4 1-1/2'. 27 El 4= w/union ball valves 0 U= locking tee handles (314"-11 O PR= Press P = Push (3/4 -1') . - - • /. 7 -.- - --. --. - . 314' ._-__-.------ -. - 10 20 30 40 RATE OF FLOW (GPM) 20 18 16 Cl) 14 U' 9 12 10 C4 8 (I) U) 04 7.5(psl 7.51ps1114' -- — 0 10 20 30 40 50 60 70 80 90 100 110 RATE OF FLOW (GPM) 1.ipS111L I. 1p5 -- 0 20 40 60 80 100 120 140 160 180 200 220 240 RATE OF FLOW (GPM) Curves developed from independent approval agencies actual tests —Consult factory fordetails indicates rated (low as determined by approval agencies. 7.5 ft/secis the typical maximum Plumbing system flow rate. Apollo Valves, Manufactured by Conbraco Industries, Inc. 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA www.apollavalves.com 1 (70-4) 941-6000 Thwbn(1ln5l)eJcEonIy n 5mth(1bwn2cponl)nofthl)inMffiuutnoIkeatheutuxumr4 ab1(g,lntomaththsEerbew *&flt'iOIti IeaevMaUrweife@www,,Un(orthrnnUwm,tñ1fwmatbm 551206003/14Page2 of 2