HomeMy WebLinkAboutPS 2022-0053; ASURION; Sign Permits/Programs (PS) Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING DIVISION PLAN CHECK ISSUES OF CONCERN DATE: 06/07/2022 PROJECT NAME: ASURION PROJECT ID: PS2022-0053 PLAN CHECK #: NA SET #: NA REVIEW #: 01 ADDRESS: 1880 MARRON ROAD, #646 APN: NA This plan check review is complete and has been APPROVED by the Planning Division. By: A Final Inspection by the Planning Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect or issues are listed on the attached page(s). Please resubmit amended plans as required. Plan Check Comments have been sent to: Nicole Evans: evans@expeditethediehl.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Jason Goff 760-602-4643 Jason.Goff@carlsbadca.gov Chris Glassen 760-602-2784 Christopher.Glassen@carlsbadca.gov ValRay Marshall 760-602-2741 ValRay.Marshall@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov ISSUES OF CONCERN: SEE ATTACHED «~ ~ C I TY OF CARLSBAD □ ~ □ □ □ □ □ □ □ □ Sign Permit No: PS2022-0053 Date: 06/07/2022 Review No.: 01 Page 2 P-29 Page 2 of 3 07/11 PLANNING DIVISION ISSUES OF CONCERN General Note: Any previous comments that have been satisfied are deleted. Repeat comments that are still not satisfied are noted as such and remain. New comments are provided below. 1ST REVIEW COMMENTS: 1. Please pay fees as included in Invoice No. 00103185 dated June 7, 2022. 2. Please sign and date the “City of Carlsbad – Planning Division Certificate of Accuracy” statement included in the application as Form P-37 and return for continued review. Without said certification, the sign permit cannot be approved. 3. Please update Title Sheet Exhibits (sheet 1) to include the following: a. Please arrange title sheet information so as to create a blank area such that the City of Carlsbad Approval Stamp can be applied. b. Please add the applicant’s contact information: Name, address, phone number and email address. 4. For wall and facia signs, please be aware that the total sign area shall not exceed 1.5 square feet per lineal feet of building frontage. Pursuant to the approved Sign Program for the North County Plaza, “Building frontage” shall be defined as the longest dimension of the building, regardless of street orientation. Please update the Sign Permit Exhibit Package to include a floor plan outlining the limits of tenant space and dimensioning the building frontage according to the above definition. Please also be aware that the sign program shows this tenant space as having a building frontage of 15 feet, which would equate to a maximum of 22 square feet of wall signage for this space. The exhibits are currently showing 38.16 square feet, almost twice the amount of signage that would be allowed for this building frontage. 5. Additionally, for wall and facia signs, please be aware that the length of any sign shall not exceed 75% of the length of the building frontage or lease space to which the sign pertains. As such, please update the Sign Permit Exhibit Package to demonstrate compliance. This may require additional graphics. 6. Sign Area shall be computed by measuring the smallest square, rectangle, triangle, circle or combination thereof, that will encompass the extreme limits of the graphic image, writing, representation, emblem or other display, together with any material or color forming an integral part of the background of the message or display or otherwise used to differentiate the sign from Sign Permit No: PS2022-0053 Date: 06/07/2022 Review No.: 01 Page 3 P-29 Page 3 of 3 07/11 the backdrop or structure against which it is placed [CMC § 21.41.070.A.1]. Please demonstrate how the sign area shown in the proposed exhibit package is being computed. 7. Please note pursuant to the approved Sign Program for the North County Plaza, letters for the proposed wall signs shall not exceed 18-inches in height. The proposed exhibits, at the most extreme, show 20-inch letter heights for wall Signs 1 and 3. Please revise the wall sign letters to comply. 8. Please note pursuant to the approved Sign Program for the North County Plaza, window Sign 2 can only be located within the upper window panel adjacent to the entrance door and cannot be of more than 144 square inches in size. Please revise the exhibit and identify the total area of this sign in square inches. Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING DIVISION PLAN CHECK ISSUES OF CONCERN DATE: 06/22/2022 PROJECT NAME: ASURION PROJECT ID: PS 2022-0053 PLAN CHECK #: NA SET #: NA REVIEW #: 02 ADDRESS: 1880 MARRON ROAD, #646 APN: NA This plan check review is complete and has been APPROVED by the Planning Division. By: A Final Inspection by the Planning Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect or issues are listed on the attached page(s). Please resubmit amended plans as required. Plan Check Comments have been sent to: Nicole Evans: evans@expeditethediehl.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Jason Goff 760-602-4643 Jason.Goff@carlsbadca.gov Chris Glassen 760-602-2784 Christopher.Glassen@carlsbadca.gov ValRay Marshall 760-602-2741 ValRay.Marshall@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov ISSUES OF CONCERN: SEE ATTACHED «~ ~ C I TY OF CARLSBAD □ ~ □ □ □ □ □ □ □ □ Sign Permit No: PS 2022-0053 Date: 06/22/2022 Review No.: 02 Page 2 P-29 Page 2 of 3 07/11 PLANNING DIVISION ISSUES OF CONCERN General Note: Any previous comments that have been satisfied are deleted. Repeat comments that are still not satisfied are noted as such and remain. New comments are provided below. 1ST REVIEW COMMENTS: 1. Please pay fees as included in Invoice No. 00103185 dated June 7, 2022. 2. [REPEAT COMMENT] Please sign and date the “City of Carlsbad – Planning Division Certificate of Accuracy” statement included in the application as Form P-37 and return for continued review. Without said certification, the sign permit cannot be approved. 3. Please update Title Sheet Exhibits (sheet 1) to include the following: a. Please arrange title sheet information so as to create a blank area such that the City of Carlsbad Approval Stamp can be applied. b. Please add the applicant’s contact information: Name, address, phone number and email address. 4. For wall and facia signs, please be aware that the total sign area shall not exceed 1.5 square feet per lineal feet of building frontage. Pursuant to the approved Sign Program for the North County Plaza, “Building frontage” shall be defined as the longest dimension of the building, regardless of street orientation. Please update the Sign Permit Exhibit Package to include a floor plan outlining the limits of tenant space and dimensioning the building frontage according to the above definition. Please also be aware that the sign program shows this tenant space as having a building frontage of 15 feet, which would equate to a maximum of 22 square feet of wall signage for this space. The exhibits are currently showing 38.16 square feet, almost twice the amount of signage that would be allowed for this building frontage. 5. Additionally, for wall and facia signs, please be aware that the length of any sign shall not exceed 75% of the length of the building frontage or lease space to which the sign pertains. As such, please update the Sign Permit Exhibit Package to demonstrate compliance. This may require additional graphics. 6. Sign Area shall be computed by measuring the smallest square, rectangle, triangle, circle or combination thereof, that will encompass the extreme limits of the graphic image, writing, representation, emblem or other display, together with any material or color forming an integral part of the background of the message or display or otherwise used to differentiate the sign from Sign Permit No: PS 2022-0053 Date: 06/22/2022 Review No.: 02 Page 3 P-29 Page 3 of 3 07/11 the backdrop or structure against which it is placed [CMC § 21.41.070.A.1]. Please demonstrate how the sign area shown in the proposed exhibit package is being computed. 7. Please note pursuant to the approved Sign Program for the North County Plaza, letters for the proposed wall signs shall not exceed 18-inches in height. The proposed exhibits, at the most extreme, show 20-inch letter heights for wall Signs 1 and 3. Please revise the wall sign letters to comply. 8. [REPEAT COMMENT] Please note pursuant to the approved Sign Program for the North County Plaza, window Sign 2 can only be located within the upper window panel adjacent to the entrance door and cannot be of more than 144 square inches in size. Please revise the exhibit and identify the total area of this sign in square inches. 2ND REVIEW: Thank you for revising the location of proposed vinyl window Sign 2. However, the area of signage proposed, at 432 square inches, still exceeds the 144 square inches that is permitted. Please revise. Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 06/23/2022 PROJECT NAME: ASURION PROJECT ID: PS2022-0053 PLAN CHECK #: NA SET #: E-FILED REVIEW #: 03 ADDRESS: 1880 MARRON ROAD, #646 APN: NA This plan check review is complete and has been APPROVED by the Planning Division. By: Jason Goff, Senior Planner Jason Goff A Final Inspection by the Planning Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Jason Goff 760-602-4643 Jason.Goff@carlsbadca.gov Chris Glassen 760-602-2784 Christopher.Glassen@carlsbadca.gov ValRay Marshall 760-602-2741 ValRay.Marshall@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov «~ ~ C I TY OF CARLSBAD □ □ □ ~ □ □ □ C cicyof Carlsbad SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov SUBMIT ONLINE THIS APPLICATION IS TO BE SUBMITTED ELECTRONICALLY. VISIT OUR ONLINE PERMIT PORTAL AT HTTPS://EG.CARLSBADCA.GOV/. NO PROCESSING WILL BEGIN UNTIL CITY HAS RECEIVED ALL REQUIRED SUBMITTAL ITEMS Background For land use permitting and requirements on signs, refer to chapter 21.41 of the Carlsbad Municipal Code, including an applicable specific plan, master plan or sign program. Depending on the scope of construction, a building permit may also be required. Please note ground-mounted/monument signs within the coastal zone also require a minor Coastal Development Permit. Requirements for signs may be subject to an existing sign program on file with the city. Have questions? Please visit the city website on options to contact Planning. TYPE OF PERMIT APPL YING FOR: IX] Sign Permit (Also use for Temporary Banners and ground mounted/monument signs) Sign Program or Modified Sign Program? Use P-11 (D) Name of Project: k,x: ,<>'('\ +t(o,4(e Related Planning Case Number(s), if any: _________________ _ PROPERTY OWNER/PROPERTY MANAGER APPLICANT NAME PRINT OR TYPE NAME PRINT OR TYPE MAILING ADDRESS MAILING ADDRESS CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRU AND CORRECT TO THE BEST OF MYK~ I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. DATE P-11 Page 1 of 2 Rev. 3/22 SUBMITTAL REQUIREMENTS: PRIOR TO PERMIT PROCESSING, APPLICANT MUST SUBMIT ALL ITEMS BELOW: ~gn/Site Plans Application for sign permits require plans be submitted consisting of a minimum of a title sheet, site plan and sign elevations containing the following information*: 1. Project Name 2. Site Address 3. Applicants contact information: Name, address, phone number and email 4. North arrow and scale. 5. Location of existing buildings or structures, parking areas, and vehicular access points to the property. For monument/ground mounted signs, provide location of the sign relative to existing driveways, easements, objects, mature landscaping, and city right-of-way. 6. Location of all existing and proposed signs for the property. 7. Distance to the property line(s) for all proposed freestanding sign(s). 8. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area (square feet) for all existing and proposed sign(s). B. Materials and color the sign(s) will be constructed of. C. Type of mounting D. Source of Illumination, if any. E. Proposed sign copy (text/lettering/design of proposed sign). *Additional supporting information may be required from applicant depending on standards, requirements, scope, design and/or property constraints. ~Certificate of Accuracy, form P-37, signed/executed ~ompleted/signed application form D 4. Application Fee (Invoiced/paid after application screened) P-11 Page 2 of 2 Rev. 3/22 CITY OF CARLSBAD· PLANNING DIVISION CERTIFICATE Of ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, Improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-~:'d1 g/site preparation. Applicant; /()u}At{;~ ~3, S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 1 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches Signage Package Location #: 646 1880 Marron Rd, Carlsbad, CA 92008 Nichole Evans 65 Cedarwood Road Stoughton MA 02072 508-369-6538 evans@expeditethediehl.com 2022-0053 Jason Goff, Senior Planner June 23, 2022 N/A • asur1on building brands together New Power to Sign Req’d.RemoveRemain As-Is Relocate Existing symbols key Reviewed By:Date: Approved Approved As Noted Not Approved, Revise As Noted drawing approval New Face-Lit Channel Letters Total SF E1 S1 FRONT ELEVATION 16.36Total SF Special InstructionsSq FtSq FtEXISTING SIGNS PROPOSED SIGNS scope of work site plan/aerial view Allowed SF 22.125 CODE INFORMATION New Primary Power to Sign Req’d. Front Elevation: Per MSP: NTE 1.5SF/1' linear building/ tenant frontage per elevation; Signs may be of Type A, fascia mounted individual internally illuminated letters or Type B, can signs, internally illuminated with colored plexiglas faces. At least 1 Type A primary sign is required per site. Type A signs NTE 18" letter height; F/S pad buildings may have single row of 24" letters or double stacked letters NTE 18" letter height for top row and total height NTE 24" letter height. Exposed raceways are prohibited. 14.75 X 1.5 = 22.125 Sq. Ft. # of Signs Allowed: NTE Sq Ft Allowance Freestanding Signs: N/A - existing multi-tenant site, all signs subject to LL review and approval Design Checklist: Cover PagePlot Plan & Signage KeyClearly interpreted code allowancesFreestanding signage setbacks 16.36 - - - - None Existing 1 revisions REV#DATE BY SHEET#REVISION NOTES: S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 2 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches □ □ □ □ building brands together S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 3 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches site visibility site plan/aerial view E DCB A A B C D E no visibility poor to limited visibility good/clear visibility Design Checklist: Visibility PageAerial View From Sheet 1Clearly defined visibility highlightingImaging from all approaches to site --- ~-.............. building brands together S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 4 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches CODE INFORMATION Front Elevation: Per MSP: NTE 1.5SF/1' linear building/ tenant frontage per elevation; Signs may be of Type A, fascia mounted individual internally illuminated letters or Type B, can signs, internally illuminated with colored plexiglas faces. At least 1 Type A primary sign is required per site. Type A signs NTE 18" letter height; F/S pad buildings may have single row of 24" letters or double stacked letters NTE 18" letter height for top row and total height NTE 24" letter height. Exposed raceways are prohibited. 14.75 X 1.5 = 22.125 Sq. Ft. # of Signs Allowed: NTE Sq Ft Allowance Freestanding Signs: N/A - existing multi-tenant site, all signs subject to LL review and approval 1 r "' L r s·s,,2· l I r-6 2 1/4' ---4 I i i i I i ubif Carlsbad 735.38 Sq ft (14' 9" X 5Q' 4") Storage 59.33 sq ft 7' 5" X 8' L_ 7' 5 _____J L_ T __J THIS FLOOR PLAN IS PROVIDED WITHOUT WARRANTY OF ANY KIND. SENSOPIA DISCLAIMS ANY WARRANTY INCLUDING, WITHOUT LIMITATION, SATISFACTORY QUALITY OR ACCURACY OF DIMENSIONS. building brands together O' 4' 8' 12' 1:94 Page 2/4 SHOPPING CENTER SITE PLAN ' • \ Leased Premises Hwy78 5 1 _____ _J --1!!1! ~ ., , I . • -----, ;8 10, 'a fl;JJ ~ Tll 11 (pi 0 = 12: 0 ~ 13 1• 1, S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 5 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches front elevation Proposed RenderingExisting Condition 28’-2” Design Checklist: RenderingsLegible, visible & properly positionedIn scaleCima work scope clearly definedWork scope by others clearly definedClearly defined sign placement - PAINT BUILDING/ADD CALLOUTS - ADD DIMENSIONS BUILDING DIMENSIONS (SCALE IF NEEDED) - ADD PLACEMENT (EQ/EQ) -ADD SIGN CALLOUT #’S Front Elevation Scope: • Fabricate & Install new signage per specications shown on detail sheets and elevations 14’-9” 1 4 ’ - 1 5 / 8 ” ***Please contact your Cima representave with any quesons or for any situaon that these requirements do not address for further instrucons o Call: 267-308-0575 and ask for a member of the Optum/United Health Team elevations / building signage FASCIA: 60.3 SQ. FT. SIGNAGE: 16.36 SQ. FT. (27% OF FASCIA) I I • 0sur1O ch re sol u SUNG I \i -t /✓\1 ll4•1FiX ,.....!..~\.:..;.,_-' . ....t:._-'_.___ building brands together S H E E T This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for your exclusive review, in connection with a project being proposed by Cima Network, Inc. it is not to be shown to anyone outside your organization, nor is it to be used, reproduced, copied or exhibited in any fashion without the expressed consent of Cima Network, Inc. Cima Network Inc. 121 New Britain Blvd. Chalfont, PA 18914 office: 267.308.0575 fax: 267.308.0577 www.cimanetwork.com Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com Client: Asurion Designer: KS PM: BB R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008 Job#: 20559 6 smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559 New Construction/Design/Drawings We received a lot of permit comments; please address them all: 1. Create new cover page with a large blank area in the top right for the city to add their stamp of approval 2. Add The following name and address to the title sheet as well: Nichole Evans, 65 Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com 3. Add in floor plan page that shows the tenant space and frontage; add in calcs showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage 4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from the sign package 5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown 6. Draw the box around the entire sign and visually demonstrate how the SF are being calculated 7. Letters NTE 18" Max height, please adjust sign 1 8. Move to window panel next to door and show the Square Inches of the vinyl. NTE 144 Square Inches Design Checklist: Detail SheetsIn scaleLED LayoutsColors, Sizes, MaterialsMounting HardwareAccurate Section Details150.0 sf Painted Red Background sign 1 93.0 sf g OP-OPTUM18-O-RM ITEMABSq. Ft.C 1'-6"1'-11"6'-7 5/8"12.7 22.6 51.0 2'-0" 3'-0" 2'-6 3/4" 3'-10 1/8" 8'-10 1/8" 13'-3 1/4" Preferred Retail Channel Letters Schedule OP-OPTUM24-O-RM OP-OPTUM36-O-RM TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION SEAL ALL BUILDING PENETRATIONSSIZE, LOCATION AND QTY NOTED ON DWG THRU BOLTING PREFERRED. ALL CONDITIONS CAN BE THRU-BOLTED WITH SLEEPER OR FENDER WASHER ON INTERIOR THRU BOLT LAG BOLT INTO MIN 3/4" PLYWOOD. (THREADS MUST PASS THRU PLYWOOD). ANTI-CRUSH SPACERS AS REQ’D FOR EIFS OR HOLLOW FASCIA LAG BOLT 3/16”Ø X 2-1/4" TAPCON CONCRETE ANCHOR INTO BRICK, CONCRETE & BLOCK. 1" MIN EMBEDMENT TAPCON EXPANSION ANCHOR INTO SOLID CONCRETE OR GROUT FILLED MASONRY. 1-1/4" MIN EMBEDMENT (NOT FOR HOLLOW MASONRY) EXPANSION ANCHOR **ALL HARDWARE MUST BE NON-CORROSIVE** RIV-NUTS WITH ALL-THREAD. UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8" ALUM ANGLE SLEEPERS SPANNING MIN (2) STRUCTURAL WALL MEMBERS. ANTI-CRUSH SPACERS AS REQ’D FOR EIFS OR HOLLOW FASCIA SLOAN LED MINI PRISM 24V, 6500K SPACED FOR EVEN ILLUMINATION TO PANEL BOX .040 ALUMINUM SIDE RETURNS PAINTED BLACK 1" TRIM CAP - COLOR: BLACK 1/4" Ø WEEP HOLES W/ LIGHT BAFFELS 3MM ACM BACKS (BLACK OUTSIDE/WHITE INSIDE) INSIDE OF LETTERS TO BE PAINTED WHITE #8 SELF DRILLING SCREWS - HEADS (BLACK) SLOAN POWER SUPPLY GROUNDING WIRE (AW 14) FROM TERMINAL LUG (PAINT GREEN) PRIMARY ELECTRIC LINE NEC 600.5 LISTED DISCONNECT SWITCH NOT WITHIN SIGHT OF SIGN (MUST BE IN LOCKABLE “OPEN” POSITION - NEC 600.6) REQUIRED FOR ALL REMOTE WIRED CHANNEL LETTERS 1/2” FMC TO ENCLOSURE BRANCH CIRCUIT CONDUCTORS SECURED TO WALL WITH STRAPS. ALL VISIBLE WIRING IS TO BE RUN IN STRAIGHT LINES AND 90° BENDS PAIGE BOX WALL STRUCTURE WILL VARY (REFER TO SITE DRAWING FOR SPECIAL CONDITIONS OR SPECIFIC MOUNTING DETAILS) 3" SECTION @ CHANNEL LETTERS SCALE: NTS 2 6 FACES: PLASKOLITE 0.125” OPTIX 2406LD VINYL: 3M #3635-222 DUAL COLOR BLACK SECONDARY LOW VOLTAGE LED WIRE OUT BACK OF LETTER INSIDE OF PAIGE WALLBUSTER PASS THRU OR APPROVED EQUIVALENT SEAL ALL BUILDING PENETRATIONS (Ul48). NON-CORROSIVE MOUNTING HARDWARE TO SUIT WALL CONDITIONS, VERIFIED VIA TECH SURVEY 1 SCALE: 1/2" = 1' 0" 1 6 FLUSH MOUNT CHANNEL LETTER LAYOUT DAY VIEW NIGHT VIEW Black PAINT: 3M #3635-222 Dual Color Perforated Black VINYL: COLORS & FINISHES: 1/2” THICK PVC LETTERS PAINTED BLACK, SECURE TO WALL WITH STUDS & SILICONE (MIN 3-4 PER LETTER) EST. ELECTRICAL LOAD (0.7) Amps @120 Volts ELECTRICAL REQUIREMENTS (1) 20 Amp/120 Volt Circuits 45 lbs.ESTIMATED WEIGHT SIGN 1 HALO LETTER SPECIFICATIONS CHANNEL LETTER INSTALLATION NOTES: 1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of Sign By Others. 2. Final Primary Hook-up By Sign Installer Where Allowed By Local Codes. 3. All Visible Wiring & Conduit To Be Run In Straight Lines & 90° Bends. 4. Seal All Building Penetrations. 5. Mounting Hardware By Sign Installer Unless Otherwise Noted. COLORS & FINISHES P1. FACE: Matthews Paint N 946SP Bright Red P2. RETURNS: Matthews Paint N 946SP Bright Red P3. SPACERS: Paint To Match PMS 7401C SIGN CONSTRUCTION 1. RETURNS: .063" Aluminum Returns Painted P2 Mechanically Fastened 2. TRIM CAP: None 3. FACES: .090” Thick Aluminum. Painted P1 4. BACKS:.177" Clear Routed Polycarb Pop-Riveted To Angle Clips 5. DRAIN HOLES: (3) 1/4”Ø Per Letter. One Must Be As Close To Back As Possible 6. HARDWARE: #8 Pan Head Screws Painted To Match Return ELECTRICAL (SIGN TO BE UL LISTED) 7. LEDS:Sloan Prism White - 6500 8. WIRE: Secondary Low Voltage Led Wire 9. PASS THRU: Paige Wallbuster Or Approved Equal. 10. POWER SUPPLY: Class 2 Power Supply Inside Enclosure. 11. ENCLOSURE: Paige Box Or Approved Equal 12. PRIMARY: 1/2” Conduit To Disconnect Switch Secure To Wall w/Straps By Others 13. SERVICE SWITCH: Located On End Of Enclosure INSTALLATION HARDWARE Threaded Rod Will Be Provided Standard. All Other Hardware Is to Be Provided By Installer As Required. 14. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Section 15. SPACERS: 3/4” Ø x 2” Long Pipe. Painted P3 16. HARDWARE: Min. 1/4"Ø Non-corrosive Hardware. (3) Per Individual Letter & Min. (2) Per Letter on Connected Script Sections 17. HARDWARE: 1/4"Ø Non-corrosive Hardware W/ Nut & Washer BUILDING & FASCIA CONDITIONS 18. WALL SURFACE: Varies 16.36 sf AS-AS18-IL-STKD-BLK-RM 1’ - 6 ” 7 1 / 4 ” 2’ - 6 1 / 2 ” 6’-5 1/4” - - - ------ - - - - - - - - - - - - - - ------ - - - - - - - - - - - - - - ------ - - - - - - - - - -- ur1 _______________ tech repair & so I uti on s Sign Company 0000 Main Street Anywhere, USA MlE:. __ l'OlTA&E. __ AMPERES NEC 600.4 markin s required @ ":;ac Listing Marks shall be on each USTED l£CT10N letter and transformer enclosure. No. 00000000 Typical UL label shown ... Sign shall be listed by a ~SE_CTI_ON_/_OF_6~ qualified electrical testing laboratory building brands together BLACK ON LIGHT FACADE