DATE: 06/07/2022 PROJECT NAME: ASURION PROJECT ID: PS2022-0053
PLAN CHECK #: NA SET #: NA REVIEW #: 01
ADDRESS: 1880 MARRON ROAD, #646 APN: NA
This plan check review is complete and has been APPROVED by the Planning
Division.
By:
A Final Inspection by the Planning Division is required Yes No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or incorrect or issues are
listed on the attached page(s). Please resubmit amended plans as required.
Plan Check Comments have been sent to: Nicole Evans: evans@expeditethediehl.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750 FIRE PREVENTION
760-602-4665
Jason Goff
760-602-4643
Jason.Goff@carlsbadca.gov
Chris Glassen
760-602-2784
Christopher.Glassen@carlsbadca.gov
ValRay Marshall
760-602-2741
ValRay.Marshall@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
ISSUES OF CONCERN: SEE ATTACHED
«~ ~ C I TY OF
CARLSBAD
□
~ □ □
□ □ □
□ □ □
Sign Permit No: PS2022-0053
Date: 06/07/2022
Review No.: 01
Page 2
P-29 Page 2 of 3 07/11
PLANNING DIVISION
ISSUES OF CONCERN
General Note: Any previous comments that have been satisfied are deleted. Repeat comments that are
still not satisfied are noted as such and remain. New comments are provided below.
1ST REVIEW COMMENTS:
1. Please pay fees as included in Invoice No. 00103185 dated June 7, 2022.
2. Please sign and date the “City of Carlsbad – Planning Division Certificate of Accuracy” statement
included in the application as Form P-37 and return for continued review. Without said
certification, the sign permit cannot be approved.
3. Please update Title Sheet Exhibits (sheet 1) to include the following:
a. Please arrange title sheet information so as to create a blank area such that the City of
Carlsbad Approval Stamp can be applied.
b. Please add the applicant’s contact information: Name, address, phone number and
email address.
4. For wall and facia signs, please be aware that the total sign area shall not exceed 1.5 square feet
per lineal feet of building frontage.
Pursuant to the approved Sign Program for the North County Plaza, “Building frontage” shall be
defined as the longest dimension of the building, regardless of street orientation.
Please update the Sign Permit Exhibit Package to include a floor plan outlining the limits of tenant
space and dimensioning the building frontage according to the above definition.
Please also be aware that the sign program shows this tenant space as having a building frontage
of 15 feet, which would equate to a maximum of 22 square feet of wall signage for this space. The
exhibits are currently showing 38.16 square feet, almost twice the amount of signage that would
be allowed for this building frontage.
5. Additionally, for wall and facia signs, please be aware that the length of any sign shall not exceed
75% of the length of the building frontage or lease space to which the sign pertains. As such,
please update the Sign Permit Exhibit Package to demonstrate compliance. This may require
additional graphics.
6. Sign Area shall be computed by measuring the smallest square, rectangle, triangle, circle or
combination thereof, that will encompass the extreme limits of the graphic image, writing,
representation, emblem or other display, together with any material or color forming an integral
part of the background of the message or display or otherwise used to differentiate the sign from
Sign Permit No: PS2022-0053
Date: 06/07/2022
Review No.: 01
Page 3
P-29 Page 3 of 3 07/11
the backdrop or structure against which it is placed [CMC § 21.41.070.A.1]. Please demonstrate
how the sign area shown in the proposed exhibit package is being computed.
7. Please note pursuant to the approved Sign Program for the North County Plaza, letters for the
proposed wall signs shall not exceed 18-inches in height. The proposed exhibits, at the most
extreme, show 20-inch letter heights for wall Signs 1 and 3. Please revise the wall sign letters to
comply.
8. Please note pursuant to the approved Sign Program for the North County Plaza, window Sign 2
can only be located within the upper window panel adjacent to the entrance door and cannot
be of more than 144 square inches in size. Please revise the exhibit and identify the total area of
this sign in square inches.
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNING DIVISION
PLAN CHECK ISSUES OF
CONCERN
DATE: 06/22/2022 PROJECT NAME: ASURION PROJECT ID: PS 2022-0053
PLAN CHECK #: NA SET #: NA REVIEW #: 02
ADDRESS: 1880 MARRON ROAD, #646 APN: NA
This plan check review is complete and has been APPROVED by the Planning
Division.
By:
A Final Inspection by the Planning Division is required Yes No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or incorrect or issues are
listed on the attached page(s). Please resubmit amended plans as required.
Plan Check Comments have been sent to: Nicole Evans: evans@expeditethediehl.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750 FIRE PREVENTION
760-602-4665
Jason Goff
760-602-4643
Jason.Goff@carlsbadca.gov
Chris Glassen
760-602-2784
Christopher.Glassen@carlsbadca.gov
ValRay Marshall
760-602-2741
ValRay.Marshall@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
ISSUES OF CONCERN: SEE ATTACHED
«~ ~ C I TY OF
CARLSBAD
□
~ □ □
□ □ □
□ □ □
Sign Permit No: PS 2022-0053
Date: 06/22/2022
Review No.: 02
Page 2
P-29 Page 2 of 3 07/11
PLANNING DIVISION
ISSUES OF CONCERN
General Note: Any previous comments that have been satisfied are deleted. Repeat comments that are
still not satisfied are noted as such and remain. New comments are provided below.
1ST REVIEW COMMENTS:
1. Please pay fees as included in Invoice No. 00103185 dated June 7, 2022.
2. [REPEAT COMMENT] Please sign and date the “City of Carlsbad – Planning Division Certificate of
Accuracy” statement included in the application as Form P-37 and return for continued review.
Without said certification, the sign permit cannot be approved.
3. Please update Title Sheet Exhibits (sheet 1) to include the following:
a. Please arrange title sheet information so as to create a blank area such that the City of
Carlsbad Approval Stamp can be applied.
b. Please add the applicant’s contact information: Name, address, phone number and
email address.
4. For wall and facia signs, please be aware that the total sign area shall not exceed 1.5 square feet
per lineal feet of building frontage.
Pursuant to the approved Sign Program for the North County Plaza, “Building frontage” shall be
defined as the longest dimension of the building, regardless of street orientation.
Please update the Sign Permit Exhibit Package to include a floor plan outlining the limits of tenant
space and dimensioning the building frontage according to the above definition.
Please also be aware that the sign program shows this tenant space as having a building frontage
of 15 feet, which would equate to a maximum of 22 square feet of wall signage for this space. The
exhibits are currently showing 38.16 square feet, almost twice the amount of signage that would
be allowed for this building frontage.
5. Additionally, for wall and facia signs, please be aware that the length of any sign shall not exceed
75% of the length of the building frontage or lease space to which the sign pertains. As such,
please update the Sign Permit Exhibit Package to demonstrate compliance. This may require
additional graphics.
6. Sign Area shall be computed by measuring the smallest square, rectangle, triangle, circle or
combination thereof, that will encompass the extreme limits of the graphic image, writing,
representation, emblem or other display, together with any material or color forming an integral
part of the background of the message or display or otherwise used to differentiate the sign from
Sign Permit No: PS 2022-0053
Date: 06/22/2022
Review No.: 02
Page 3
P-29 Page 3 of 3 07/11
the backdrop or structure against which it is placed [CMC § 21.41.070.A.1]. Please demonstrate
how the sign area shown in the proposed exhibit package is being computed.
7. Please note pursuant to the approved Sign Program for the North County Plaza, letters for the
proposed wall signs shall not exceed 18-inches in height. The proposed exhibits, at the most
extreme, show 20-inch letter heights for wall Signs 1 and 3. Please revise the wall sign letters to
comply.
8. [REPEAT COMMENT] Please note pursuant to the approved Sign Program for the North County
Plaza, window Sign 2 can only be located within the upper window panel adjacent to the
entrance door and cannot be of more than 144 square inches in size. Please revise the exhibit
and identify the total area of this sign in square inches.
2ND REVIEW: Thank you for revising the location of proposed vinyl window Sign 2. However, the
area of signage proposed, at 432 square inches, still exceeds the 144 square inches that is
permitted. Please revise.
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 06/23/2022 PROJECT NAME: ASURION PROJECT ID: PS2022-0053
PLAN CHECK #: NA SET #: E-FILED REVIEW #: 03
ADDRESS: 1880 MARRON ROAD, #646 APN: NA
This plan check review is complete and has been APPROVED by the Planning
Division.
By: Jason Goff, Senior Planner Jason Goff
A Final Inspection by the Planning Division is required Yes No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750 FIRE PREVENTION
760-602-4665
Jason Goff
760-602-4643
Jason.Goff@carlsbadca.gov
Chris Glassen
760-602-2784
Christopher.Glassen@carlsbadca.gov
ValRay Marshall
760-602-2741
ValRay.Marshall@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
«~ ~ C I TY OF
CARLSBAD
□ □
□
~ □
□
□
C cicyof
Carlsbad
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(442) 339-2610
www.carlsbadca.gov
SUBMIT ONLINE
THIS APPLICATION IS TO BE SUBMITTED ELECTRONICALLY. VISIT OUR ONLINE PERMIT PORTAL AT
HTTPS://EG.CARLSBADCA.GOV/. NO PROCESSING WILL BEGIN UNTIL CITY HAS RECEIVED ALL REQUIRED
SUBMITTAL ITEMS
Background
For land use permitting and requirements on signs, refer to chapter 21.41 of the Carlsbad Municipal
Code, including an applicable specific plan, master plan or sign program. Depending on the scope
of construction, a building permit may also be required. Please note ground-mounted/monument
signs within the coastal zone also require a minor Coastal Development Permit. Requirements for
signs may be subject to an existing sign program on file with the city.
Have questions? Please visit the city website on options to contact Planning.
TYPE OF PERMIT APPL YING FOR:
IX] Sign Permit (Also use for Temporary Banners and ground mounted/monument signs)
Sign Program or Modified Sign Program? Use P-11 (D)
Name of Project: k,x: ,<>'('\ +t(o,4(e
Related Planning Case Number(s), if any: _________________ _
PROPERTY OWNER/PROPERTY MANAGER APPLICANT
NAME PRINT OR TYPE NAME PRINT OR TYPE
MAILING ADDRESS MAILING ADDRESS
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
I CERTIFY THAT I AM THE LEGAL OWNER
AND THAT ALL THE ABOVE INFORMATION
IS TRU AND CORRECT TO THE BEST OF
MYK~
I CERTIFY THAT I AM THE REPRESENTATIVE
OF THE LEGAL OWNER AND THAT ALL THE
ABOVE INFORMATION IS TRUE AND CORRECT
TO THE BEST OF MY KNOWLEDGE.
DATE
P-11 Page 1 of 2 Rev. 3/22
SUBMITTAL REQUIREMENTS:
PRIOR TO PERMIT PROCESSING, APPLICANT MUST SUBMIT ALL ITEMS BELOW:
~gn/Site Plans
Application for sign permits require plans be submitted consisting of a minimum of a title sheet, site
plan and sign elevations containing the following information*:
1. Project Name
2. Site Address
3. Applicants contact information: Name, address, phone number and email
4. North arrow and scale.
5. Location of existing buildings or structures, parking areas, and vehicular access points to the
property. For monument/ground mounted signs, provide location of the sign relative to existing
driveways, easements, objects, mature landscaping, and city right-of-way.
6. Location of all existing and proposed signs for the property.
7. Distance to the property line(s) for all proposed freestanding sign(s).
8. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area (square feet) for all existing and proposed sign(s).
B. Materials and color the sign(s) will be constructed of.
C. Type of mounting
D. Source of Illumination, if any.
E. Proposed sign copy (text/lettering/design of proposed sign).
*Additional supporting information may be required from applicant depending on standards,
requirements, scope, design and/or property constraints.
~Certificate of Accuracy, form P-37, signed/executed
~ompleted/signed application form
D 4. Application Fee (Invoiced/paid after application screened)
P-11 Page 2 of 2 Rev. 3/22
CITY OF CARLSBAD· PLANNING DIVISION
CERTIFICATE Of ACCURACY
I certify all documents and plans clearly and accurately show all existing and
all proposed buildings, structures, access roads, and utilities/utility
easements. All proposed land use activities, Improvements to land, and/or
building modifications or additions are clearly labeled on the site plan of the
approved plan set. I understand that any potentially existing detail within
these plans inconsistent with the site plan are not approved and may be
required to be altered or removed. The submitted documents and plans show
the correct dimensions of the property, the buildings, and structures and their
setbacks from property lines and from one another, access roads/easements,
and utilities. The existing and proposed use of land and of each building as
stated is true and correct. Further, all improvements existing on the property
were completed in accordance with all regulations in existence at the time of
their construction, unless otherwise noted. All easements and other
encumbrances to development have been accurately shown and labeled as
well as all on-~:'d1 g/site preparation.
Applicant; /()u}At{;~ ~3,
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 1
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
Signage Package
Location #: 646
1880 Marron Rd, Carlsbad, CA 92008
Nichole Evans
65 Cedarwood Road
Stoughton MA 02072
508-369-6538
evans@expeditethediehl.com
2022-0053
Jason Goff, Senior Planner
June 23, 2022
N/A
• asur1on
building brands together
New Power to Sign Req’d.RemoveRemain As-Is Relocate Existing
symbols key
Reviewed By:Date:
Approved Approved As Noted Not Approved, Revise As Noted
drawing approval
New Face-Lit Channel Letters
Total
SF
E1 S1
FRONT ELEVATION
16.36Total
SF
Special InstructionsSq FtSq FtEXISTING SIGNS PROPOSED SIGNS
scope of work
site plan/aerial view
Allowed SF 22.125
CODE INFORMATION
New Primary Power to Sign Req’d.
Front Elevation:
Per MSP: NTE 1.5SF/1' linear building/ tenant frontage per elevation; Signs may
be of Type A, fascia mounted individual internally illuminated letters or Type B,
can signs, internally illuminated with colored plexiglas faces. At least 1 Type A
primary sign is required per site. Type A signs NTE 18" letter height; F/S pad
buildings may have single row of 24" letters or double stacked letters NTE 18"
letter height for top row and total height NTE 24" letter height. Exposed raceways
are prohibited.
14.75 X 1.5 = 22.125 Sq. Ft.
# of Signs Allowed: NTE Sq Ft Allowance
Freestanding Signs:
N/A - existing multi-tenant site,
all signs subject to LL review and
approval
Design Checklist: Cover PagePlot Plan & Signage KeyClearly interpreted code allowancesFreestanding signage setbacks
16.36
-
-
-
-
None Existing
1
revisions
REV#DATE BY SHEET#REVISION NOTES:
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 2
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
□
□ □ □
building brands together
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 3
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
site visibility
site plan/aerial view
E
DCB
A
A
B
C
D
E
no visibility poor to limited visibility good/clear visibility
Design Checklist: Visibility PageAerial View From Sheet 1Clearly defined visibility highlightingImaging from all approaches to site
---
~-..............
building brands together
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 4
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
CODE INFORMATION
Front Elevation:
Per MSP: NTE 1.5SF/1' linear building/ tenant frontage per elevation; Signs may
be of Type A, fascia mounted individual internally illuminated letters or Type B,
can signs, internally illuminated with colored plexiglas faces. At least 1 Type A
primary sign is required per site. Type A signs NTE 18" letter height; F/S pad
buildings may have single row of 24" letters or double stacked letters NTE 18"
letter height for top row and total height NTE 24" letter height. Exposed raceways
are prohibited.
14.75 X 1.5 = 22.125 Sq. Ft.
# of Signs Allowed: NTE Sq Ft Allowance
Freestanding Signs:
N/A - existing multi-tenant site,
all signs subject to LL review and
approval
1
r
"'
L
r s·s,,2·
l I
r-6 2 1/4' ---4
I i i i
I i
ubif Carlsbad
735.38 Sq ft (14' 9" X 5Q' 4")
Storage
59.33 sq ft
7' 5" X 8'
L_ 7' 5 _____J L_ T __J
THIS FLOOR PLAN IS PROVIDED WITHOUT WARRANTY OF ANY KIND. SENSOPIA DISCLAIMS ANY WARRANTY
INCLUDING, WITHOUT LIMITATION, SATISFACTORY QUALITY OR ACCURACY OF DIMENSIONS.
building brands together
O' 4' 8' 12'
1:94
Page 2/4
SHOPPING CENTER SITE PLAN
' • \
Leased Premises
Hwy78
5 1
_____ _J
--1!!1! ~ ., ,
I . • -----,
;8 10, 'a fl;JJ ~ Tll
11 (pi
0
= 12: 0 ~
13
1•
1,
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 5
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
front elevation
Proposed RenderingExisting Condition
28’-2”
Design Checklist: RenderingsLegible, visible & properly positionedIn scaleCima work scope clearly definedWork scope by others clearly definedClearly defined sign placement
- PAINT BUILDING/ADD CALLOUTS
- ADD DIMENSIONS BUILDING DIMENSIONS (SCALE IF NEEDED)
- ADD PLACEMENT (EQ/EQ)
-ADD SIGN CALLOUT #’S
Front Elevation Scope:
• Fabricate & Install new signage per specications shown on detail sheets and elevations
14’-9”
1
4
’
-
1
5
/
8
”
***Please contact your Cima representa ve with any ques ons or for any situa on
that these requirements do not address for further instruc ons
o Call: 267-308-0575 and ask for a member of the Optum/United Health Team
elevations / building signage
FASCIA: 60.3 SQ. FT.
SIGNAGE: 16.36 SQ. FT.
(27% OF FASCIA)
I
I • 0sur1O
ch re sol
u
SUNG I \i
-t /✓\1
ll4•1FiX ,.....!..~\.:..;.,_-' . ....t:._-'_.___
building brands together
S
H
E
E
T
This is an original, unpublished drawing, created by Cima Network, Inc. It is submitted for
your exclusive review, in connection with a project being proposed by Cima Network, Inc.
it is not to be shown to anyone outside your organization, nor is it to be used, reproduced,
copied or exhibited in any fashion without the expressed consent of Cima Network, Inc.
Cima Network Inc.
121 New Britain Blvd.
Chalfont, PA 18914
office: 267.308.0575
fax: 267.308.0577
www.cimanetwork.com
Nichole Evans65 Cedarwood Road Stoughton MA 02072508-369-6538evans@expeditethediehl.com
Client: Asurion
Designer: KS PM: BB
R E V I S I O N 2D AT E 6 . 2 0 . 2 2Address: 1880 Marron Rd, Carlsbad, CA 92008
Job#: 20559 6
smb://10.0.1.20/Clients/Asurion/LOCATIONS/CA/Asurion #646 - Carlsbad, CA/20559
New Construction/Design/Drawings
We received a lot of permit comments; please address them all:
1. Create new cover page with a large blank area in the top right for the city to add their
stamp of approval
2. Add The following name and address to the title sheet as well: Nichole Evans, 65
Cedarwood Road, Stoughton MA 02072, 508-369-6538, evans@expeditethediehl.com
3. Add in floor plan page that shows the tenant space and frontage; add in calcs
showing that they are allowed 1.5SF for 1 Lineal Foot of Frontage
4. We are only allowed 22 SF max here so show only sign 1 and remove sign 3 from
the sign package
5. Show that sign 1 does not exceed 75" of the fascia; this has to be visually shown
6. Draw the box around the entire sign and visually demonstrate how the SF are being
calculated
7. Letters NTE 18" Max height, please adjust sign 1
8. Move to window panel next to door and show the Square Inches of the vinyl. NTE
144 Square Inches
Design Checklist: Detail SheetsIn scaleLED LayoutsColors, Sizes, MaterialsMounting HardwareAccurate Section Details150.0 sf Painted Red Background
sign 1
93.0 sf
g
OP-OPTUM18-O-RM
ITEMABSq. Ft.C
1'-6"1'-11"6'-7 5/8"12.7
22.6
51.0
2'-0"
3'-0"
2'-6 3/4"
3'-10 1/8"
8'-10 1/8"
13'-3 1/4"
Preferred Retail Channel Letters Schedule
OP-OPTUM24-O-RM
OP-OPTUM36-O-RM
TYPICAL APPROVED MOUNTING OPTIONS PER WALL CONDITION
SEAL ALL BUILDING PENETRATIONSSIZE, LOCATION AND QTY NOTED ON DWG
THRU BOLTING PREFERRED. ALL CONDITIONS CAN BE THRU-BOLTED WITH SLEEPER OR FENDER WASHER ON INTERIOR
THRU BOLT
LAG BOLT INTO MIN 3/4" PLYWOOD.
(THREADS MUST PASS THRU
PLYWOOD). ANTI-CRUSH SPACERS
AS REQ’D FOR EIFS OR HOLLOW
FASCIA
LAG BOLT
3/16ӯ X 2-1/4" TAPCON CONCRETE
ANCHOR INTO BRICK, CONCRETE
& BLOCK. 1" MIN EMBEDMENT
TAPCON
EXPANSION ANCHOR INTO SOLID
CONCRETE OR GROUT FILLED
MASONRY. 1-1/4" MIN EMBEDMENT
(NOT FOR HOLLOW MASONRY)
EXPANSION ANCHOR
**ALL HARDWARE MUST BE NON-CORROSIVE**
RIV-NUTS WITH ALL-THREAD.
UNI-STRUT OR 1-1/2" X 1-1/2" X 1/8"
ALUM ANGLE SLEEPERS SPANNING
MIN (2) STRUCTURAL WALL MEMBERS.
ANTI-CRUSH SPACERS AS REQ’D FOR
EIFS OR HOLLOW FASCIA
SLOAN LED MINI PRISM 24V, 6500K
SPACED FOR EVEN ILLUMINATION TO PANEL BOX
.040 ALUMINUM SIDE RETURNS
PAINTED BLACK
1" TRIM CAP - COLOR: BLACK
1/4" Ø WEEP HOLES W/ LIGHT BAFFELS
3MM ACM BACKS (BLACK OUTSIDE/WHITE INSIDE)
INSIDE OF LETTERS TO BE
PAINTED WHITE
#8 SELF DRILLING SCREWS - HEADS (BLACK)
SLOAN POWER SUPPLY
GROUNDING WIRE (AW 14) FROM TERMINAL LUG
(PAINT GREEN)
PRIMARY ELECTRIC LINE
NEC 600.5
LISTED DISCONNECT SWITCH
NOT WITHIN SIGHT OF SIGN
(MUST BE IN LOCKABLE “OPEN”
POSITION - NEC 600.6)
REQUIRED FOR ALL REMOTE
WIRED CHANNEL LETTERS
1/2” FMC TO ENCLOSURE
BRANCH CIRCUIT CONDUCTORS
SECURED TO WALL WITH
STRAPS.
ALL VISIBLE WIRING IS TO BE
RUN IN STRAIGHT LINES AND
90° BENDS
PAIGE BOX
WALL STRUCTURE WILL VARY
(REFER TO SITE DRAWING FOR SPECIAL CONDITIONS
OR SPECIFIC MOUNTING DETAILS)
3"
SECTION @ CHANNEL LETTERS
SCALE: NTS
2
6
FACES: PLASKOLITE 0.125” OPTIX 2406LD
VINYL: 3M #3635-222 DUAL COLOR BLACK
SECONDARY LOW VOLTAGE LED WIRE
OUT BACK OF LETTER INSIDE OF
PAIGE WALLBUSTER PASS THRU
OR APPROVED EQUIVALENT
SEAL ALL BUILDING PENETRATIONS
(Ul48).
NON-CORROSIVE MOUNTING HARDWARE
TO SUIT WALL CONDITIONS, VERIFIED VIA TECH SURVEY
1 SCALE: 1/2" = 1' 0"
1
6
FLUSH MOUNT CHANNEL LETTER LAYOUT
DAY VIEW NIGHT VIEW
Black
PAINT:
3M #3635-222 Dual Color Perforated Black
VINYL:
COLORS & FINISHES:
1/2” THICK PVC LETTERS PAINTED BLACK,
SECURE TO WALL WITH STUDS & SILICONE
(MIN 3-4 PER LETTER)
EST. ELECTRICAL LOAD
(0.7) Amps @120 Volts
ELECTRICAL REQUIREMENTS
(1) 20 Amp/120 Volt Circuits
45 lbs.ESTIMATED WEIGHT
SIGN 1
HALO LETTER SPECIFICATIONS
CHANNEL LETTER INSTALLATION NOTES:
1. Sufficient Primary Dedicated Circuit Within 5' Of Center Of
Sign By Others.
2. Final Primary Hook-up By Sign Installer Where Allowed By
Local Codes.
3. All Visible Wiring & Conduit To Be Run In Straight Lines &
90° Bends.
4. Seal All Building Penetrations.
5. Mounting Hardware By Sign Installer Unless Otherwise
Noted.
COLORS & FINISHES
P1. FACE: Matthews Paint N 946SP Bright Red
P2. RETURNS: Matthews Paint N 946SP Bright Red
P3. SPACERS: Paint To Match PMS 7401C
SIGN CONSTRUCTION
1. RETURNS: .063" Aluminum Returns Painted P2
Mechanically Fastened
2. TRIM CAP: None
3. FACES: .090” Thick Aluminum. Painted P1
4. BACKS:.177" Clear Routed Polycarb Pop-Riveted To
Angle Clips
5. DRAIN HOLES: (3) 1/4ӯ Per Letter. One Must Be As
Close To Back As Possible
6. HARDWARE: #8 Pan Head Screws Painted To
Match Return
ELECTRICAL (SIGN TO BE UL LISTED)
7. LEDS:Sloan Prism White - 6500
8. WIRE: Secondary Low Voltage Led Wire
9. PASS THRU: Paige Wallbuster Or Approved Equal.
10. POWER SUPPLY: Class 2 Power Supply Inside
Enclosure.
11. ENCLOSURE: Paige Box Or Approved Equal
12. PRIMARY: 1/2” Conduit To Disconnect Switch Secure
To Wall w/Straps By Others
13. SERVICE SWITCH: Located On End Of Enclosure
INSTALLATION HARDWARE
Threaded Rod Will Be Provided Standard. All Other Hardware
Is to Be Provided By Installer As Required.
14. RIV-NUTS: 1/4-20. Minimum (3) Per Individual Letter &
Min. (2) Per Letter on Connected Script Section
15. SPACERS: 3/4” Ø x 2” Long Pipe. Painted P3
16. HARDWARE: Min. 1/4"Ø Non-corrosive Hardware. (3)
Per Individual Letter & Min. (2) Per Letter on Connected
Script Sections
17. HARDWARE: 1/4"Ø Non-corrosive Hardware W/ Nut &
Washer
BUILDING & FASCIA CONDITIONS
18. WALL SURFACE: Varies
16.36 sf
AS-AS18-IL-STKD-BLK-RM
1’
-
6
”
7
1
/
4
”
2’
-
6
1
/
2
”
6’-5 1/4”
- - - ------ - - - - - - - - - - - - - - ------ - - - - - - - - - - - - - - ------ - - - - - - - - - --
ur1
_______________ tech repair & so I uti on s
Sign Company
0000 Main Street Anywhere, USA
MlE:. __
l'OlTA&E. __
AMPERES
NEC 600.4 markin s required
@ ":;ac Listing Marks shall be on each
USTED l£CT10N letter and transformer enclosure.
No. 00000000 Typical UL label shown ...
Sign shall be listed by a
~SE_CTI_ON_/_OF_6~ qualified electrical testing laboratory
building brands together
BLACK ON LIGHT FACADE