Loading...
HomeMy WebLinkAboutPS 2020-0154; ONE MEDICAL; Sign Permits/Programs (PS)Ccicyof Carlsbad r · iED [1C T ,; 0 2020 ,,/CSBAD 111/SIO\J REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: _O_n_e_M_e_di_c_al ______________________ _ Address of Project: 7740 El Camino Real Carlsbad, CA 92009 Assessor Parcel Number: 216-124-16-00 -------'------------------- Re I ate d Planning Case Number(S): ____________________ _ TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (b) Commercial (e) Service Station (c) Office/Industrial (f) Prof. Care (g) Theater (h) Gov'UChurch/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA 0) Produce Stand (k) Nursery (I) P-U/OS Zone Yes □ No □ Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes □ SIGNORDINANCE: Yes □ No □ COASTALZONE: YesONoO P-11 Page 1 of 4 No □ No □ Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall 0 Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No □ Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Pole** Monument** Wall 1 29.6 SF 23" Suspended/Projecting I ~F 2.5" Directional \ 1.1 SF Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN ALLOWED AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim ""'Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I 1 I P/L / Sipt ;e Re~ Showbuildiq/s / : ' I ~---{-Show setbacks from all cvlts --- I I I ' I I I Show all pniperty -· I P/L ' I :/ I cvl, line i ----------ar.--- • • Sipt Vuibility I Street Name(1) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: _________ sq. ft. Total Building Street Frontage: linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: sq. ft. ---------Tot a I Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 .. PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) AP Beacon Carlsbad, LP Matthews Sign LLC By: Ashley McDonald, Authorized Agent PETER LAPSIW ALA MAILING ADDRESS MAILING ADDRESS 1616 Camden Road, Suite 210 560 South Quince St Charlotte NC 28203 Escondido, CA 92025 CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE 6~ 1J'l-S,-~ I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE. o.~~~ 9/17/2020 faiJ:..1Jt~ 09/29/2020 SIGNATU~= DATE SIGNATURt' DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: E:J,u "' vd.. ... \ lkwz..Jela Date: \ o/ ;OJ 7 b P-11 Page 4 of 4 Rev. 02/28/18 September 9, 2020 City of Carlsbad Community Development Department 1635 Faraday Avenue Carlsbad, CA 92008 Re: One Medical ASANA PARTNIIIS Tenant Signage Permit Application The Beacon, 7710-7770 El Camino Real To Whom It May Concern, AP Beacon Carlsbad, LP has reviewed the above referenced Tenant's signage and has approved Tenant's application for submittal to the City. Please do not hesitate to contact me with any questions at amcdonald@asanapartners.com or at (310) 702-6061. Sincerely, ~Id Director -Development Asana Partners CHARLOTTE: 704. 710.8032 COLUMBIA: 803.832.4694 WEB: asanapartners.com ALL WORK TO COMPLY WITH: • ••• • 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA ELECTRICAL CODE BUILDING one medical SITE ADDRESS: ONE MEDICAL 7740 EL CAMINO REAL Carlsbad, CA 92009 APN: 216-124-1 6-00 LEGAL: PAR D\ PARCEL MAP NO 10283 CONTRACTOR: MATTHEW SIGNS LLC 560 S QUTNCE STREET ESCOND1DO CA 92025 SCOPE OF WORK: TO TNSTALL (2) NON-ILLUMINATED WALL SIGNS, (I) BLADE SIGN NON ILLUMINATED AND (I) TENANT PANELS ON EXISTING WAY FTNDING SIGN Project No. 200890 Signage Package 77 40 El Camino Real Carlsbad, CA 92009 I I IDENTITI I I SIGNAGE I BRANDED ENVIRONMENTS I MAINTENANCE Site Plan -Overview Project No. 200890 Project Signage Package Location 77 40 8 Camm Rea~ F Cat\sbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer lrniss Rev. Art Lila Roblin Rev. Date 07.02.2020 Page Rev. 002 Rev. Details Removed VW2-I This sign des'gn It txclusive p,optrty ol ldtntttl Resoorces, LTD .. and os the result of the original Ind creative work of ~·• employees. This drawwtg a submitted to lhe customer f0t the sole purpose of purchase of the design or s1gna1e manufactured to this dHi&n, by ldtnliti Resources, LTD. DistriOUtion to or use of this sign desian by anyone oulSKK' of the customer's orcanizat.on, w,thOUt exp,1ssed. written authofiUuon t,y ldenu, RHOlKCH, LTD. is prohibud . IDENTITI 425 N Martingale Rd 18th Floor Schaumburg, IL 60173 Office 847.301.0510 ldentiti.net y ~) '--.I ) :) IU ~ ~ 8 s ;;------- ------... ------... ------... mo EL CAMINO REAL ------... ------... , &I I O•-+ t+O I -, • 1n I , O-.. •u f-,,o.~t-t<> ------... ------... ~@ # • .,.". ------... ------... --. ' ------... 708.00 in :s2Jt -Ojn)--C- ------... ------... ----------.....-----' ------... ?"lrh I ~ '=7791 ~ =- ---------=---=--~ (]) Front Elevation S1-1 Proposed Signage = 29.6 SF Relevant Signage Code Wall sign allowed square footage: 30 sq ft -Wall signs TE 24' letter height, total aggregate sign area per tenant NTE 150 sq ft(lncludes vehicle directionals, viny~ wall signs,blade signs, and rear multi-tenant identifiers. Wall sign width NTE 75% of facade width Sign Type 1 • thick aluminum letters externally illuminated by gooseneck lights Mounting Pin mounted Color Palette ■ PMS 2333C Project No. 200890 Project Signage Package Location 77 40 El Gamm Rea~ F Gar1sbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer lmiss Rev. Art Stephanie Rev. Date 05.27.20 Page Rev. 001 Rev. Details Added gooseneck spec and revised sign placement This s11n design JS exclusive property of tdentiti Resources, LTD., and is 1~• result of the Ofiginal 1nd creative wort of it"s emp!oyees. 1 his drawing is submitted to the custome1 for the sole purpose of purchase of the des gn or signage manufactured 10 this design, by ldentiti Resow-ces, LTD. Distribution to or use of this sign deSl&J'l by anyone outside of the customer's organization, without expressed, wriuen 1uthorizetion by ldentiti Resources. LTD. is prohibtted. IDENTITI 4 25 N Martingale Rd 18th Floor Schaumburg, IL 60173 Office 847.301.0510 identiti.net 10' • EXISTING 1 ft -4 3/e in 16.375 in I i f -23 in 1 ft -11 in 16.375 in ---l 1 ft -4 3/e in i - 69'-2" 700.00in (58' -4·) CENTER LOGO OVER CENTER ARCH • PROPOSED NOTE: -ldentiti to supply and install gooseneck lights -MSP calls out individual letters 185.75 in 15 ft-5 3/4 in 163.25 in 13 ft-7 ¼ in Goose neck lighting (QTY: 5) - Scale: 3/4" -12" Rear Elevation S2-1 Proposed Signage = 20 SF Relevant Slgnage Code Rear panel sign allowance: 20 sq ft Sign Type 1/2" Thick painted acrylic letters, stud mounted to .090 painted aluminum panel Mounting Aluminum panel with pre-applied letters, installed over eixsting LL provided panel Color Palette ■ PMS 2333C BM Decorators White Project No. 200890 Project Signage Package Location 77 40 8 Camilo Rea~ F Cartsbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer !miss Rev. Art N/A Rev. Date 00.00.00 Page Rev. 000 Rev. Details N/A This sign design is ex.elusive property of ldentiti Resources. LTD., and is the result oft~ 01igNI and creative work of it's emptoyees. This drawing is submitted to lhe customes for the sole purpose of purchase of the deslgn or signage manufactured to this design, by ldentiti Resources, LTD. Dislrieotion 10 or use of !his sign design by anyone outside of the customer's ora:anization, without e,r.pressed, written authorization by ldentiti Resources, LTD. is prohibited. IDENTITI 425 N Martingale Rd 18th Floor Schaumburg, ll 60173 Office 847.301.0510 identiti.net l 24.00 in 2 ft -0 in l 60ac:: Scale: 3/32" = 1 '-0" t 13.50 in 1 ft -1 ½ in .t "I" 9.625 in 9 5/a in .I r··1 \ I Woodlired Pizza 120.00 in 10 ft-0 in 109.00 in 9 ft -1 in 95.75 in 7 ft -11 ¾ in 120in I 1 1 + one medical 24 in f•=-'T I I NOTE: -ldentiti to supply and install gooseneck lights Scale: 3/4" -12" Sign Specifications SPEC Proposed Signage = N/ A Sign Type 1/2" Thick painted acrylic letters, stud mounted to .090 painted aluminum panel Mounting Aluminum panel with pre-applied letters, installed over eixsting LL provided panel Color Palette ■ PMS 2333C N/A Project No. 200890 Project Signage Package Location 77 40 El Camilo Rea~ F Carlsbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer lmiss Rev. Art Liz Morgan Rev. Date 010.01.20 Page Rev. 004 Rev. Details Add lighting mount plate This sign design is exclusNe property of tdentiti Resources, LTD., and is Ille result oft~ original and creative wor~ of it's employees. l h1s drawinc 1s subm1ued to the customer for the sole purpose of purchase of the design or signage manufactured to this design, by ldentiti Resources, LTD. Distribution to or use of this sign design by anyone outsKie of the customer's organization, w1th0t1t expressed, written authorization by ldentiti Resources, LTD. is prohibited. IDENTITI 425 N Martingale Rd 18th Floor Schaumburg, IL 60173 Office 847.301.0510 identiti.net ~~-\ 000 .. <v~e~ <SI• "< • ••• • one medical Remote 12V transformer required. Prewired with a 3ft, 18-2 direct burial cord. Adjustable cast brass knuckle with thumb screw. Silicone gasket for water tight sealing. 3 4 5 6 7 8 CONSTRUCTION: CORROSION RESISTANT CAST BRASS LENS: CLEAR ANO HEAT RESISTANT TEMPERED LENS VOLTAGE & WATTAGE: 12V & 5 WATTS COLOR TEMPERATURE & WMENS: 2700K I 450LMS MOUNTING: 5" WAU MOUNT INTO CANOPY FINISH: ANTIQUE BRONZE 2·1h~ 6½"'3/-/4w 24" --------1 2 ) .. , 40.00 in SIGN BAND Scale: NTS Front Elevation (Blade Sign) BS1-1 Proposed Signage = 2. 19 SF Relevant Slgnage Code 1 per tenant space maxiumum 2' x 2' Sign Type D/S Non-Illuminated Hanging Aluminum Cabinet w / Acrylic Letters Mounting Eyebolts fixed into beam walkway Sign hung from chain min 8' AFF Color Palette ■ PMS 2333C White Acrylic Project No. 200890 Project Signage Package Location 7740 El Gamino Rea~ F Carlsbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer lrniss Rev. Art Stephanie Rev. Date 10.15.2020 Page Rev. 006 Rev. Details Revised logo placeemnt This sign design is excklsive property of ld&ntiti Resources, LTD., and is the result of lhe original and creative work of it's employees. This drawing is submitted to the customer lor the sole purpose ot purchase of the design or signage manufactured to this design, by ldentiti Resources. LTD. Distribution to or use of this sign des1gn by anyone outstde of the customer's organization. without expressed, written authorizatton by ldentiti Resources, LTD. is prohibited. IDENTITI 425 N Martingale Rd 18th Floor Schaumburg, IL 60173 Office 847.301.0510 identiti.net ..&. EXISTING ATOM: 2.50" --- FIELD VERIFICATION REQUIRED CITY & LL APPROVAL REQUIRED ..... PROPOSED RENDER IS ESTIMATE ONLY FIELD VERIFICATION NEEDED 24.00 in (2 ft-0 in) r 16.00 in --, 19.00 in i 13.13 in (1 ft-11/s in) 1 PAINTED WHITE ACRYLIC LOGO & LETTERS STUD MOUNTED TO FACE 8'AFF 7 r Depth: 1.00 in Scale: r -12• - Vehicle Wayfinding VW1-1 Proposed Signage = 1. 1 SF Relevant Signage Code Dart metal cut-oot dimensional letters pin mounted to building face Total sign area NTE 1 SF for each linear foot store front -Letter height NTE 18" -Total wall signs cannot cover more than 75% of tenant frontage -Letters illuminated by gooseneck lighting only 59' x 1 • 59 SF Sign Type 1 /2 Thick Painted Acrylic Letters, Applied to a new painted .090 aluminum panel(QTY: 1) Mounting Mounted into wood post Color Palette ■ PMS 2333C Panel: White Project No. 200890 Project Signage Package Location 7740 B Camino Rea~ F Carlsbad, CA 92009 Orig. Draft 03.31.20 Project Mgr. Alex Hildreth Designer lrniss Rev. Art Stephanie Rev. Date 05.27.20 Page Rev. 001 Rev. Details Rescaled sign and adjusted layout This sign design is e,clusive property ol ldentiti Resources, LTD., and is tnt result of the original and creative wOf'k of it's 1mpk>yee1. This drawing is submitted to the customer tor the sole purpose or purchase of the design or signage manufactured to this desi&n, by lctentiti Resources, LTD. Distribution to or use of this sign desi,n by anyone outside of the customer's organization, without eJ.Pressed, written authorization by ldentiti Resources, LTD. is prohibited. IDENTITI 425 N Martingale Rd 18th Floor Schaumburg, IL 60173 Office 847.301.0510 identiti.net ~ f 24.00 in (2 ft -0 in) 20.00 in ⇒ :t 2.125 in 6.625 in 2.25 in I ~ ·:· one medical I 1 1 . 0 Note: Single sided sign QTY: 1 Locations see site plan NOTE: -Color to be verified on site ~ 2.00in 2.15 in 2.00in ~ t TENANT HERE 4'-0" e fabricated sign panel painted white 0 removable individual panel with applied graphic and arrow e 2" round wood post with finish to match architectural wood 0 2" round powder coated metal sleeve to protect wood from moisture and landscape equipment TOP VIEW Scale: 3/1'+= 1'-0 SIDE VIEW Scale: 3/1'+= 1'-0 Scale: 1 1/2" -12"